mirror of
https://github.com/emsesp/EMS-ESP32.git
synced 2025-12-10 01:39:54 +03:00
Refactor MQTT subscriptions #173
This commit is contained in:
@@ -26,8 +26,6 @@ uuid::log::Logger Boiler::logger_{F_(boiler), uuid::log::Facility::CONSOLE};
|
||||
|
||||
Boiler::Boiler(uint8_t device_type, int8_t device_id, uint8_t product_id, const std::string & version, const std::string & name, uint8_t flags, uint8_t brand)
|
||||
: EMSdevice(device_type, device_id, product_id, version, name, flags, brand) {
|
||||
LOG_DEBUG(F("Adding new Boiler with device ID 0x%02X"), device_id);
|
||||
|
||||
// cascaded heatingsources, only some values per individual heatsource (hs)
|
||||
if (device_id != EMSdevice::EMS_DEVICE_ID_BOILER) {
|
||||
uint8_t hs = device_id - EMSdevice::EMS_DEVICE_ID_BOILER_1; // heating source id, count from 0
|
||||
|
||||
@@ -26,8 +26,6 @@ uuid::log::Logger Heatpump::logger_{F_(heatpump), uuid::log::Facility::CONSOLE};
|
||||
|
||||
Heatpump::Heatpump(uint8_t device_type, uint8_t device_id, uint8_t product_id, const std::string & version, const std::string & name, uint8_t flags, uint8_t brand)
|
||||
: EMSdevice(device_type, device_id, product_id, version, name, flags, brand) {
|
||||
LOG_DEBUG(F("Adding new Heat Pump module with device ID 0x%02X"), device_id);
|
||||
|
||||
// telegram handlers
|
||||
register_telegram_type(0x042B, F("HP1"), true, MAKE_PF_CB(process_HPMonitor1));
|
||||
register_telegram_type(0x047B, F("HP2"), true, MAKE_PF_CB(process_HPMonitor2));
|
||||
|
||||
@@ -26,8 +26,6 @@ uuid::log::Logger Mixer::logger_{F_(mixer), uuid::log::Facility::CONSOLE};
|
||||
|
||||
Mixer::Mixer(uint8_t device_type, uint8_t device_id, uint8_t product_id, const std::string & version, const std::string & name, uint8_t flags, uint8_t brand)
|
||||
: EMSdevice(device_type, device_id, product_id, version, name, flags, brand) {
|
||||
LOG_DEBUG(F("Adding new Mixer with device ID 0x%02X"), device_id);
|
||||
|
||||
// Pool module
|
||||
if (flags == EMSdevice::EMS_DEVICE_FLAG_MP) {
|
||||
register_telegram_type(0x5BA, F("HpPoolStatus"), true, MAKE_PF_CB(process_HpPoolStatus));
|
||||
|
||||
@@ -26,8 +26,6 @@ uuid::log::Logger Solar::logger_{F_(solar), uuid::log::Facility::CONSOLE};
|
||||
|
||||
Solar::Solar(uint8_t device_type, uint8_t device_id, uint8_t product_id, const std::string & version, const std::string & name, uint8_t flags, uint8_t brand)
|
||||
: EMSdevice(device_type, device_id, product_id, version, name, flags, brand) {
|
||||
LOG_DEBUG(F("Adding new Solar module with device ID 0x%02X"), device_id);
|
||||
|
||||
// telegram handlers
|
||||
if (flags == EMSdevice::EMS_DEVICE_FLAG_SM10) {
|
||||
register_telegram_type(0x97, F("SM10Monitor"), false, MAKE_PF_CB(process_SM10Monitor));
|
||||
|
||||
@@ -28,8 +28,6 @@ uuid::log::Logger Switch::logger_ {
|
||||
|
||||
Switch::Switch(uint8_t device_type, uint8_t device_id, uint8_t product_id, const std::string & version, const std::string & name, uint8_t flags, uint8_t brand)
|
||||
: EMSdevice(device_type, device_id, product_id, version, name, flags, brand) {
|
||||
LOG_DEBUG(F("Adding new Switch with device ID 0x%02X"), device_id);
|
||||
|
||||
register_telegram_type(0x9C, F("WM10MonitorMessage"), false, MAKE_PF_CB(process_WM10MonitorMessage));
|
||||
register_telegram_type(0x9D, F("WM10SetMessage"), false, MAKE_PF_CB(process_WM10SetMessage));
|
||||
register_telegram_type(0x1E, F("WM10TempMessage"), false, MAKE_PF_CB(process_WM10TempMessage));
|
||||
|
||||
@@ -115,7 +115,7 @@ Thermostat::Thermostat(uint8_t device_type, uint8_t device_id, uint8_t product_i
|
||||
monitor_typeids = {0x02A5, 0x02A6, 0x02A7, 0x02A8};
|
||||
set_typeids = {};
|
||||
for (uint8_t i = 0; i < monitor_typeids.size(); i++) {
|
||||
register_telegram_type(monitor_typeids[i], F("CRFMonitor"), true, MAKE_PF_CB(process_CRFMonitor));
|
||||
register_telegram_type(monitor_typeids[i], F("CRFMonitor"), false, MAKE_PF_CB(process_CRFMonitor));
|
||||
}
|
||||
|
||||
// RC300/RC100
|
||||
@@ -161,18 +161,14 @@ Thermostat::Thermostat(uint8_t device_type, uint8_t device_id, uint8_t product_i
|
||||
}
|
||||
}
|
||||
|
||||
// reserve some memory for the heating circuits (max 4 to start with)
|
||||
heating_circuits_.reserve(4);
|
||||
|
||||
if (actual_master_thermostat != device_id) {
|
||||
LOG_DEBUG(F("Adding new thermostat with device ID 0x%02X"), device_id);
|
||||
return; // don't fetch data if more than 1 thermostat
|
||||
}
|
||||
|
||||
//
|
||||
// this next section is only for the master thermostat....
|
||||
//
|
||||
LOG_DEBUG(F("Adding new thermostat with device ID 0x%02X (as master)"), device_id);
|
||||
LOG_DEBUG(F("Setting this thermostat (device ID 0x%02X) to be the master"), device_id);
|
||||
|
||||
// register device values for common values (not heating circuit)
|
||||
register_device_values();
|
||||
@@ -340,6 +336,7 @@ std::shared_ptr<Thermostat::HeatingCircuit> Thermostat::heating_circuit(std::sha
|
||||
if (!toggle_) {
|
||||
return nullptr;
|
||||
}
|
||||
|
||||
/*
|
||||
* at this point we have discovered a new heating circuit
|
||||
*/
|
||||
@@ -458,7 +455,7 @@ void Thermostat::publish_ha_config_hc(uint8_t hc_num) {
|
||||
// enable the a special "thermostat_hc<n>" topic to take both mode strings and floats for each of the heating circuits
|
||||
std::string topic2(Mqtt::MQTT_TOPIC_MAX_SIZE, '\0');
|
||||
snprintf(&topic2[0], topic2.capacity() + 1, "thermostat_hc%d", hc_num);
|
||||
register_mqtt_topic(topic2, [=](const char * m) { return thermostat_ha_cmd(m, hc_num); });
|
||||
Mqtt::subscribe(EMSdevice::DeviceType::THERMOSTAT, topic2, [=](const char * m) { return thermostat_ha_cmd(m, hc_num); });
|
||||
}
|
||||
|
||||
// for HA specifically when receiving over MQTT in the thermostat topic
|
||||
|
||||
Reference in New Issue