Refactor MQTT subscriptions #173

This commit is contained in:
proddy
2021-11-01 23:31:30 +01:00
parent 40a7026d4c
commit 01bace4048
38 changed files with 873 additions and 942 deletions

View File

@@ -26,8 +26,6 @@ uuid::log::Logger Boiler::logger_{F_(boiler), uuid::log::Facility::CONSOLE};
Boiler::Boiler(uint8_t device_type, int8_t device_id, uint8_t product_id, const std::string & version, const std::string & name, uint8_t flags, uint8_t brand)
: EMSdevice(device_type, device_id, product_id, version, name, flags, brand) {
LOG_DEBUG(F("Adding new Boiler with device ID 0x%02X"), device_id);
// cascaded heatingsources, only some values per individual heatsource (hs)
if (device_id != EMSdevice::EMS_DEVICE_ID_BOILER) {
uint8_t hs = device_id - EMSdevice::EMS_DEVICE_ID_BOILER_1; // heating source id, count from 0