force sel temp on RC35 temperature change - #310

This commit is contained in:
Paul
2020-01-26 21:10:07 +01:00
parent 55fcfb132f
commit 03489d43f4
5 changed files with 16 additions and 9 deletions

View File

@@ -120,9 +120,10 @@
#define EMS_OFFSET_RC35Set_mode 7 // position of thermostat mode
#define EMS_OFFSET_RC35Set_temp_day 2 // position of thermostat setpoint temperature for day time
#define EMS_OFFSET_RC35Set_temp_night 1 // position of thermostat setpoint temperature for night time
#define EMS_OFFSET_RC35Set_temp_holiday 3 // temp during holiday 0x47
#define EMS_OFFSET_RC35Set_heatingtype 0 // floor heating = 3 0x47
#define EMS_OFFSET_RC35Set_circuitcalctemp 14 // calculated circuit temperature 0x48
#define EMS_OFFSET_RC35Set_temp_holiday 3 // temp during holiday mode
#define EMS_OFFSET_RC35Set_heatingtype 0 // e.g. floor heating = 3
#define EMS_OFFSET_RC35Set_circuitcalctemp 14 // calculated circuit temperature
#define EMS_OFFSET_RC35Set_seltemp 37 // selected temp
// Easy specific
#define EMS_TYPE_EasyStatusMessage 0x0A // reading values on an Easy Thermostat