mirror of
https://github.com/emsesp/EMS-ESP32.git
synced 2025-12-08 00:39:50 +03:00
writing to Junkers thermostats - #138
This commit is contained in:
@@ -11,6 +11,7 @@ and this project adheres to [Semantic Versioning](https://semver.org/spec/v2.0.0
|
||||
- Solar Module SM200 support
|
||||
- `set master_thermostat <product id>` to choose with thermostat is master when there are multiple on the bus
|
||||
- MM10 Mixer support (thanks @MichaelDvP)
|
||||
- First implementation of writing to Junker Thermostats (thanks @Neonox31)
|
||||
|
||||
### Fixed
|
||||
- set boiler warm water temp on Junkers/Bosch HT3
|
||||
|
||||
71
src/ems.cpp
71
src/ems.cpp
@@ -534,7 +534,7 @@ void _ems_sendTelegram() {
|
||||
_EMS_RxTelegram EMS_RxTelegram; // create new Rx object
|
||||
EMS_RxTelegram.length = EMS_TxTelegram.length; // full length of telegram
|
||||
EMS_RxTelegram.telegram = EMS_TxTelegram.data;
|
||||
EMS_RxTelegram.data_length = 0; // ignore #data=
|
||||
EMS_RxTelegram.data_length = 0; // surpress #data=
|
||||
EMS_RxTelegram.timestamp = myESP.getSystemTime(); // now
|
||||
_debugPrintTelegram("Sending raw: ", &EMS_RxTelegram, COLOR_CYAN, true);
|
||||
}
|
||||
@@ -1209,7 +1209,6 @@ void _process_RC35StatusMessage(_EMS_RxTelegram * EMS_RxTelegram) {
|
||||
_setValue8(EMS_RxTelegram, &EMS_Thermostat.hc[hc].setpoint_roomTemp, EMS_OFFSET_RC35StatusMessage_setpoint); // is * 2, force to single byte
|
||||
}
|
||||
|
||||
// ignore if the value is unset. Hopefully it will be picked up via a later message
|
||||
_setValue(EMS_RxTelegram, &EMS_Thermostat.hc[hc].curr_roomTemp, EMS_OFFSET_RC35StatusMessage_curr); // is * 10
|
||||
_setValue(EMS_RxTelegram, &EMS_Thermostat.hc[hc].day_mode, EMS_OFFSET_RC35StatusMessage_mode, 1);
|
||||
_setValue(EMS_RxTelegram, &EMS_Thermostat.hc[hc].summer_mode, EMS_OFFSET_RC35StatusMessage_mode, 0);
|
||||
@@ -1290,13 +1289,15 @@ void _process_RCPLUSStatusMode(_EMS_RxTelegram * EMS_RxTelegram) {
|
||||
}
|
||||
|
||||
/**
|
||||
* FR10/FR50/FR100 Junkers - type x006F
|
||||
* FR10/FR50/FR100 Junkers - type x6F
|
||||
* e.g. for FR10: 90 00 FF 00 00 6F 03 01 00 BE 00 BF
|
||||
* for FW100: 90 00 FF 00 00 6F 03 02 00 D7 00 DA F3 34 00 C4
|
||||
*/
|
||||
void _process_JunkersStatusMessage(_EMS_RxTelegram * EMS_RxTelegram) {
|
||||
uint8_t hc = EMS_THERMOSTAT_DEFAULTHC - 1; // use HC1
|
||||
EMS_Thermostat.hc[hc].active = true;
|
||||
int8_t hc = _getHeatingCircuit(EMS_RxTelegram); // which HC is it, 0-3
|
||||
if (hc == -1) {
|
||||
return;
|
||||
}
|
||||
|
||||
_setValue(EMS_RxTelegram, &EMS_Thermostat.hc[hc].curr_roomTemp, EMS_OFFSET_JunkersStatusMessage_curr); // value is * 10
|
||||
_setValue(EMS_RxTelegram, &EMS_Thermostat.hc[hc].setpoint_roomTemp, EMS_OFFSET_JunkersStatusMessage_setpoint); // value is * 10
|
||||
@@ -2286,6 +2287,44 @@ void ems_setThermostatTemp(float temperature, uint8_t hc_num, uint8_t temptype)
|
||||
EMS_TxTelegram.type_validate = EMS_TxTelegram.type;
|
||||
}
|
||||
|
||||
else if (model == EMS_DEVICE_FLAG_JUNKERS) {
|
||||
switch (temptype) {
|
||||
case 1: // change the no frost temp
|
||||
EMS_TxTelegram.offset = EMS_OFFSET_JunkersSetMessage_no_frost_temp;
|
||||
break;
|
||||
case 2: // change the night temp
|
||||
EMS_TxTelegram.offset = EMS_OFFSET_JunkersSetMessage_night_temp;
|
||||
break;
|
||||
case 3: // change the day temp
|
||||
EMS_TxTelegram.offset = EMS_OFFSET_JunkersSetMessage_day_temp;
|
||||
break;
|
||||
default:
|
||||
case 0: // automatic selection, if no type is defined, we use the standard code
|
||||
// not sure if this is correct for Junkers
|
||||
if (EMS_Thermostat.hc[hc_num - 1].day_mode == 0) {
|
||||
EMS_TxTelegram.offset = EMS_OFFSET_JunkersSetMessage_night_temp;
|
||||
} else if (EMS_Thermostat.hc[hc_num - 1].day_mode == 1) {
|
||||
EMS_TxTelegram.offset = EMS_OFFSET_JunkersSetMessage_day_temp;
|
||||
}
|
||||
break;
|
||||
}
|
||||
|
||||
if (hc_num == 1) {
|
||||
EMS_TxTelegram.type = EMS_TYPE_JunkersSetMessage_HC1;
|
||||
EMS_TxTelegram.comparisonPostRead = EMS_TYPE_JunkersStatusMessage_HC1;
|
||||
} else if (hc_num == 2) {
|
||||
EMS_TxTelegram.type = EMS_TYPE_JunkersSetMessage_HC1;
|
||||
EMS_TxTelegram.comparisonPostRead = EMS_TYPE_JunkersStatusMessage_HC1;
|
||||
} else if (hc_num == 3) {
|
||||
EMS_TxTelegram.type = EMS_TYPE_JunkersSetMessage_HC1;
|
||||
EMS_TxTelegram.comparisonPostRead = EMS_TYPE_JunkersStatusMessage_HC1;
|
||||
} else if (hc_num == 4) {
|
||||
EMS_TxTelegram.type = EMS_TYPE_JunkersSetMessage_HC1;
|
||||
EMS_TxTelegram.comparisonPostRead = EMS_TYPE_JunkersStatusMessage_HC1;
|
||||
}
|
||||
EMS_TxTelegram.type_validate = EMS_TxTelegram.type;
|
||||
}
|
||||
|
||||
EMS_TxTelegram.length = EMS_MIN_TELEGRAM_LENGTH;
|
||||
EMS_TxTelegram.dataValue = (uint8_t)((float)temperature * (float)2); // value * 2
|
||||
EMS_TxTelegram.comparisonOffset = EMS_TxTelegram.offset;
|
||||
@@ -2379,6 +2418,23 @@ void ems_setThermostatMode(uint8_t mode, uint8_t hc_num) {
|
||||
EMS_TxTelegram.offset = EMS_OFFSET_RC35Set_mode;
|
||||
EMS_TxTelegram.type_validate = EMS_TxTelegram.type;
|
||||
|
||||
} else if (model == EMS_DEVICE_FLAG_JUNKERS) {
|
||||
if (hc_num == 1) {
|
||||
EMS_TxTelegram.type = EMS_TYPE_JunkersSetMessage_HC1;
|
||||
EMS_TxTelegram.comparisonPostRead = EMS_TYPE_JunkersStatusMessage_HC1;
|
||||
} else if (hc_num == 2) {
|
||||
EMS_TxTelegram.type = EMS_TYPE_JunkersSetMessage_HC2;
|
||||
EMS_TxTelegram.comparisonPostRead = EMS_TYPE_JunkersStatusMessage_HC2;
|
||||
} else if (hc_num == 3) {
|
||||
EMS_TxTelegram.type = EMS_TYPE_JunkersSetMessage_HC3;
|
||||
EMS_TxTelegram.comparisonPostRead = EMS_TYPE_JunkersStatusMessage_HC3;
|
||||
} else if (hc_num == 4) {
|
||||
EMS_TxTelegram.type = EMS_TYPE_JunkersSetMessage_HC4;
|
||||
EMS_TxTelegram.comparisonPostRead = EMS_TYPE_JunkersStatusMessage_HC4;
|
||||
}
|
||||
EMS_TxTelegram.offset = EMS_OFFSET_JunkersSetMessage_set_mode;
|
||||
EMS_TxTelegram.type_validate = EMS_TxTelegram.type;
|
||||
|
||||
} else if (model == EMS_DEVICE_FLAG_RC300) {
|
||||
EMS_TxTelegram.offset = EMS_OFFSET_RCPLUSSet_mode;
|
||||
|
||||
@@ -2720,7 +2776,10 @@ const _EMS_Type EMS_Types[] = {
|
||||
{EMS_DEVICE_UPDATE_FLAG_THERMOSTAT, EMS_TYPE_RCPLUSStatusMode, "RCPLUSStatusMode", _process_RCPLUSStatusMode},
|
||||
|
||||
// Junkers FR10
|
||||
{EMS_DEVICE_UPDATE_FLAG_THERMOSTAT, EMS_TYPE_JunkersStatusMessage, "JunkersStatusMessage", _process_JunkersStatusMessage},
|
||||
{EMS_DEVICE_UPDATE_FLAG_THERMOSTAT, EMS_TYPE_JunkersStatusMessage_HC1, "JunkersStatusMessage_HC1", _process_JunkersStatusMessage},
|
||||
{EMS_DEVICE_UPDATE_FLAG_THERMOSTAT, EMS_TYPE_JunkersStatusMessage_HC2, "JunkersStatusMessage_HC2", _process_JunkersStatusMessage},
|
||||
{EMS_DEVICE_UPDATE_FLAG_THERMOSTAT, EMS_TYPE_JunkersStatusMessage_HC3, "JunkersStatusMessage_HC3", _process_JunkersStatusMessage},
|
||||
{EMS_DEVICE_UPDATE_FLAG_THERMOSTAT, EMS_TYPE_JunkersStatusMessage_HC4, "JunkersStatusMessage_HC4", _process_JunkersStatusMessage},
|
||||
|
||||
// Mixing devices MM10 - MM400
|
||||
{EMS_DEVICE_UPDATE_FLAG_MIXING, EMS_TYPE_MMPLUSStatusMessage_HC1, "MMPLUSStatusMessage_HC1", _process_MMPLUSStatusMessage},
|
||||
|
||||
@@ -181,13 +181,26 @@ const _EMS_Device_Types EMS_Devices_Types[] = {
|
||||
#define EMS_OFFSET_RCPLUSSet_temp_setpoint 8 // temp setpoint, when changing of templevel (in auto) value is reset and set to FF
|
||||
#define EMS_OFFSET_RCPLUSSet_manual_setpoint 10 // manual setpoint
|
||||
|
||||
// Junkers FR10, FR50, FW100 (EMS Plus)
|
||||
#define EMS_TYPE_JunkersStatusMessage 0x6F // is an automatic thermostat broadcast giving us temps
|
||||
// Junkers FR10, FR50, FW100, FW120 (EMS Plus)
|
||||
#define EMS_TYPE_JunkersStatusMessage_HC1 0x6F // is an automatic thermostat broadcast giving us temps
|
||||
#define EMS_TYPE_JunkersStatusMessage_HC2 0x70 // is an automatic thermostat broadcast giving us temps
|
||||
#define EMS_TYPE_JunkersStatusMessage_HC3 0x71 // is an automatic thermostat broadcast giving us temps
|
||||
#define EMS_TYPE_JunkersStatusMessage_HC4 0x72 // is an automatic thermostat broadcast giving us temps
|
||||
|
||||
#define EMS_OFFSET_JunkersStatusMessage_daymode 0 // 3 = day, 2 = night
|
||||
#define EMS_OFFSET_JunkersStatusMessage_mode 1 // current mode, 1 = manual, 2 = auto
|
||||
#define EMS_OFFSET_JunkersStatusMessage_setpoint 2 // setpoint temp
|
||||
#define EMS_OFFSET_JunkersStatusMessage_curr 4 // current temp
|
||||
|
||||
#define EMS_TYPE_JunkersSetMessage_HC1 0x65 // EMS type to set temperature on thermostat for heating circuit 1
|
||||
#define EMS_TYPE_JunkersSetMessage_HC2 0x66 // EMS type to set temperature on thermostat for heating circuit 2
|
||||
#define EMS_TYPE_JunkersSetMessage_HC3 0x67 // EMS type to set temperature on thermostat for heating circuit 3
|
||||
#define EMS_TYPE_JunkersSetMessage_HC4 0x68 // EMS type to set temperature on thermostat for heating circuit 4
|
||||
#define EMS_OFFSET_JunkersSetMessage_day_temp 0x11 // EMS offset to set temperature on thermostat for day mode
|
||||
#define EMS_OFFSET_JunkersSetMessage_night_temp 0x10 // EMS offset to set temperature on thermostat for night mode
|
||||
#define EMS_OFFSET_JunkersSetMessage_no_frost_temp 0x0F // EMS offset to set temperature on thermostat for no frost mode
|
||||
#define EMS_OFFSET_JunkersSetMessage_set_mode 0x0E // EMS offset to set mode on thermostat
|
||||
|
||||
// MM100 (EMS Plus)
|
||||
#define EMS_TYPE_MMPLUSStatusMessage_HC1 0x01D7 // mixer status HC1
|
||||
#define EMS_TYPE_MMPLUSStatusMessage_HC2 0x01D8 // mixer status HC2
|
||||
@@ -294,14 +307,14 @@ static const _EMS_Device EMS_Devices[] = {
|
||||
{76, EMS_DEVICE_TYPE_THERMOSTAT, "Sieger ES73", EMS_DEVICE_FLAG_RC35}, // 0x10
|
||||
|
||||
// Junkers
|
||||
{105, EMS_DEVICE_TYPE_THERMOSTAT, "Junkers FW100", EMS_DEVICE_FLAG_JUNKERS | EMS_DEVICE_FLAG_NO_WRITE}, // 0x10, cannot write
|
||||
{105, EMS_DEVICE_TYPE_THERMOSTAT, "Junkers FW100", EMS_DEVICE_FLAG_JUNKERS}, // 0x10
|
||||
{106, EMS_DEVICE_TYPE_THERMOSTAT, "Junkers FW200", EMS_DEVICE_FLAG_JUNKERS | EMS_DEVICE_FLAG_NO_WRITE}, // 0x10, cannot write
|
||||
{107, EMS_DEVICE_TYPE_THERMOSTAT, "Junkers FR100", EMS_DEVICE_FLAG_JUNKERS | EMS_DEVICE_FLAG_NO_WRITE}, // 0x10, cannot write
|
||||
{108, EMS_DEVICE_TYPE_THERMOSTAT, "Junkers FR110", EMS_DEVICE_FLAG_JUNKERS | EMS_DEVICE_FLAG_NO_WRITE}, // 0x10, cannot write
|
||||
{111, EMS_DEVICE_TYPE_THERMOSTAT, "Junkers FR10", EMS_DEVICE_FLAG_JUNKERS | EMS_DEVICE_FLAG_NO_WRITE}, // 0x10, cannot write
|
||||
{111, EMS_DEVICE_TYPE_THERMOSTAT, "Junkers FR10", EMS_DEVICE_FLAG_JUNKERS}, // 0x10
|
||||
{147, EMS_DEVICE_TYPE_THERMOSTAT, "Junkers FR50", EMS_DEVICE_FLAG_JUNKERS | EMS_DEVICE_FLAG_NO_WRITE}, // 0x10, cannot write
|
||||
{191, EMS_DEVICE_TYPE_THERMOSTAT, "Junkers FR120", EMS_DEVICE_FLAG_JUNKERS | EMS_DEVICE_FLAG_NO_WRITE}, // 0x10, cannot write
|
||||
{192, EMS_DEVICE_TYPE_THERMOSTAT, "Junkers FW120", EMS_DEVICE_FLAG_JUNKERS | EMS_DEVICE_FLAG_NO_WRITE}, // 0x10, cannot write
|
||||
{147, EMS_DEVICE_TYPE_THERMOSTAT, "Junkers FR50", EMS_DEVICE_FLAG_JUNKERS | EMS_DEVICE_FLAG_NO_WRITE} // 0x10, cannot write
|
||||
{192, EMS_DEVICE_TYPE_THERMOSTAT, "Junkers FW120", EMS_DEVICE_FLAG_JUNKERS} // 0x10
|
||||
|
||||
|
||||
};
|
||||
|
||||
@@ -1 +1 @@
|
||||
#define APP_VERSION "1.9.5b9"
|
||||
#define APP_VERSION "1.9.5b10"
|
||||
|
||||
Reference in New Issue