@@ -182,17 +182,17 @@ const _EMS_Type EMS_Types[] = {
};
// calculate sizes of arrays at compile
uint8_t _EMS_Types_max = ArraySize(EMS_Types); // number of defined types
uint8_t _Boiler_Types_max = ArraySize(Boiler_Types); // number of boiler models
uint8_t _Solar_Module_Types_max = ArraySize(SolarModule_Types);// number of solar module types
uint8_t _Other_Types_max = ArraySize(Other_Types); // number of other ems devices
uint8_t _Thermostat_Types_max = ArraySize(Thermostat_Types); // number of defined thermostat types
uint8_t _EMS_Types_max = ArraySize(EMS_Types); // number of defined types
uint8_t _Boiler_Types_max = ArraySize(Boiler_Types); // number of boiler models
uint8_t _Solar_Module_Types_max = ArraySize(SolarModule_Types); // number of solar module types
uint8_t _Other_Types_max = ArraySize(Other_Types); // number of other ems devices
uint8_t _Thermostat_Types_max = ArraySize(Thermostat_Types); // number of defined thermostat types
// these structs contain the data we store from the Boiler and Thermostat
_EMS_Boiler EMS_Boiler; // for boiler
_EMS_Thermostat EMS_Thermostat; // for thermostat
_EMS_Boiler EMS_Boiler; // for boiler
_EMS_Thermostat EMS_Thermostat; // for thermostat
_EMS_SolarModule EMS_SolarModule; // for solar modules
_EMS_Other EMS_Other; // for other known EMS devices
_EMS_Other EMS_Other; // for other known EMS devices
// CRC lookup table with poly 12 for faster checking
const uint8_t ems_crc_table[] = {0x00, 0x02, 0x04, 0x06, 0x08, 0x0A, 0x0C, 0x0E, 0x10, 0x12, 0x14, 0x16, 0x18, 0x1A, 0x1C, 0x1E, 0x20, 0x22, 0x24, 0x26,
@@ -308,16 +308,16 @@ void ems_init() {
EMS_SolarModule.EnergyLastHour = EMS_VALUE_SHORT_NOTSET;
EMS_SolarModule.EnergyToday = EMS_VALUE_SHORT_NOTSET;
EMS_SolarModule.EnergyTotal = EMS_VALUE_SHORT_NOTSET;
EMS_SolarModule.device_id = EMS_ID_NONE;
EMS_SolarModule.model_id = EMS_MODEL_NONE;
EMS_SolarModule.product_id = EMS_ID_NONE;
EMS_SolarModule.device_id = EMS_ID_NONE;
EMS_SolarModule.model_id = EMS_MODEL_NONE;
EMS_SolarModule.product_id = EMS_ID_NONE;
// Other EMS devices values
EMS_Other.HPModulation = EMS_VALUE_INT_NOTSET;
EMS_Other.HPSpeed = EMS_VALUE_INT_NOTSET;
EMS_Other.device_id = EMS_ID_NONE;
EMS_Other.model_id = EMS_MODEL_NONE;
EMS_Other.product_id = EMS_ID_NONE;
EMS_Other.HPModulation = EMS_VALUE_INT_NOTSET;
EMS_Other.HPSpeed = EMS_VALUE_INT_NOTSET;
EMS_Other.device_id = EMS_ID_NONE;
EMS_Other.model_id = EMS_MODEL_NONE;
EMS_Other.product_id = EMS_ID_NONE;
// calculated values
EMS_Boiler.tapwaterActive = EMS_VALUE_INT_NOTSET; // Hot tap water is on/off
@@ -1306,10 +1306,10 @@ void _process_RCPLUSStatusMode(_EMS_RxTelegram * EMS_RxTelegram) {
*/
void _process_JunkersStatusMessage(_EMS_RxTelegram * EMS_RxTelegram) {
if (EMS_RxTelegram->offset == 0) {
// e.g. for FR10: 90 00 FF 00 00 6F 03 01 00 BE 00 BF
// e.g. for FW100: 90 00 FF 00 00 6F 03 02 00 D7 00 DA F3 34 00 C4
EMS_Thermostat.curr_roomTemp = _toShort(EMS_OFFSET_JunkersStatusMessage_curr); // value is * 10
EMS_Thermostat.setpoint_roomTemp = _toShort(EMS_OFFSET_JunkersStatusMessage_setpoint); // value is * 10
// e.g. for FR10: 90 00 FF 00 00 6F 03 01 00 BE 00 BF
// e.g. for FW100: 90 00 FF 00 00 6F 03 02 00 D7 00 DA F3 34 00 C4
EMS_Thermostat.curr_roomTemp = _toShort(EMS_OFFSET_JunkersStatusMessage_curr); // value is * 10
EMS_Thermostat.setpoint_roomTemp = _toShort(EMS_OFFSET_JunkersStatusMessage_setpoint); // value is * 10
}
}
@@ -1473,20 +1473,19 @@ void _process_HPMonitor2(_EMS_RxTelegram * EMS_RxTelegram) {
* Junkers ISM1 Solar Module - type 0x0003 EMS+ for energy readings
*/
void _process_ISM1StatusMessage(_EMS_RxTelegram * EMS_RxTelegram) {
if (EMS_RxTelegram->offset == 0) {
// e.g. B0 00 FF 00 00 03 32 00 00 00 00 13 00 D6 00 00 00 FB D0 F0
EMS_SolarModule.collectorTemp = _toShort(4); // Collector Temperature
EMS_SolarModule.bottomTemp = _toShort(6); // Temperature Bottom of Solar Boiler
EMS_SolarModule.EnergyLastHour = _toShort(2) * 10; // Solar Energy produced in last hour
EMS_SolarModule.pump = _bitRead(8,0); // Solar pump on (1) or off (0)
// EMS_Other.SM = true;
// e.g. B0 00 FF 00 00 03 32 00 00 00 00 13 00 D6 00 00 00 FB D0 F0
EMS_SolarModule.collectorTemp = _toShort(4); // Collector Temperature
EMS_SolarModule.bottomTemp = _toShort(6); // Temperature Bottom of Solar Boiler
EMS_SolarModule.EnergyLastHour = _toShort(2) * 10; // Solar Energy produced in last hour
EMS_SolarModule.pump = _bitRead(8, 0); // Solar pump on (1) or off (0)
// EMS_Other.SM = true;
}
if (EMS_RxTelegram->offset == 4) {
// e.g. B0 00 FF 04 00 03 02 E5
EMS_SolarModule.collectorTemp = _toShort(0); // Collector Temperature
// EMS_Other.SM = true;
// e.g. B0 00 FF 04 00 03 02 E5
EMS_SolarModule.collectorTemp = _toShort(0); // Collector Temperature
// EMS_Other.SM = true;
}
}
@@ -1675,22 +1674,25 @@ void _process_Version(_EMS_RxTelegram * EMS_RxTelegram) {
}
if (typeFound) {
myDebug_P(PSTR("Solar Module found: %s (DeviceID:0x%02X ProductID:%d Version:%s)"), SolarModule_Types[i].model_string, SolarModule_Types[i].device_id, product_id, version);
myDebug_P(PSTR("Solar Module found: %s (DeviceID:0x%02X ProductID:%d Version:%s)"),
SolarModule_Types[i].model_string,
SolarModule_Types[i].device_id,
product_id,
version);
// add to list
_addDevice(product_id, SolarModule_Types[i].device_id, version, SolarModule_Types[i].model_string);
// EMS_Other.SM = true; // we have detected a Solar Module (SM10, SM100, ISM1 ...)
myDebug_P(PSTR("Solar Module support enabled."));
EMS_SolarModule.model_id = Other_Types[i].model_id;
EMS_SolarModule.device_id = Other_Types[i].device_id;
EMS_SolarModule.product_id = product_id;
EMS_SolarModule.model_id = Other_Types[i].model_id;
EMS_SolarModule.device_id = Other_Types[i].device_id;
EMS_SolarModule.product_id = product_id;
strlcpy(EMS_SolarModule.version, version, sizeof(EMS_SolarModule.version));
// fetch Solar Module values
ems_getSolarModuleValues();
return;
}
@@ -1714,12 +1716,11 @@ void _process_Version(_EMS_RxTelegram * EMS_RxTelegram) {
if (Other_Types[i].device_id == EMS_ID_HP) {
EMS_Other.HP = true; // we have detected a HP
myDebug_P(PSTR("HeatPump support enabled."));
EMS_Other.model_id = Other_Types[i].model_id;
EMS_Other.device_id = Other_Types[i].device_id;
EMS_Other.product_id = product_id;
EMS_Other.model_id = Other_Types[i].model_id;
EMS_Other.device_id = Other_Types[i].device_id;
EMS_Other.product_id = product_id;
strlcpy(EMS_Other.version, version, sizeof(EMS_Other.version));
// fetch Solar Module values > not yet implemented
}
return;
@@ -1871,17 +1872,14 @@ void ems_getBoilerValues() {
* Get other values from EMS devices
*/
void ems_getSolarModuleValues() {
uint8_t product_id = EMS_SolarModule.product_id;
if (ems_getSolarModuleEnabled()) {
if (product_id == EMS_PRODUCTID_SM10) {
ems_doReadCommand(EMS_TYPE_SM10Monitor, EMS_ID_SM); // fetch all from SM10Monitor
}
else if (product_id == EMS_PRODUCTID_SM100) {
} else if (product_id == EMS_PRODUCTID_SM100) {