HA MQTT Discovert - added remaining values - HomeAssistant Discovery #288

This commit is contained in:
proddy
2020-10-06 20:53:32 +02:00
parent 2d9286aea3
commit 13297334cf
12 changed files with 356 additions and 351 deletions

View File

@@ -54,6 +54,7 @@ class Boiler : public EMSdevice {
uint8_t last_boilerState = 0xFF; // remember last state of heating and warm water on/off
bool changed_ = false;
bool mqtt_ha_config_ = false; // HA MQTT Discovery
static constexpr uint8_t EMS_TYPE_UBAParameterWW = 0x33;
static constexpr uint8_t EMS_TYPE_UBAFunctionTest = 0x1D;
@@ -66,40 +67,40 @@ class Boiler : public EMSdevice {
static constexpr uint8_t EMS_BOILER_SELFLOWTEMP_HEATING = 20; // was originally 70, changed to 30 for issue #193, then to 20 with issue #344
// UBAParameterWW
uint8_t wWActivated_ = EMS_VALUE_BOOL_NOTSET; // Warm Water activated
uint8_t wWSelTemp_ = EMS_VALUE_UINT_NOTSET; // Warm Water selected temperature
uint8_t wWCircPump_ = EMS_VALUE_BOOL_NOTSET; // Warm Water circulation pump available
uint8_t wWCircPumpMode_ = EMS_VALUE_UINT_NOTSET; // Warm Water circulation pump mode
uint8_t wWChargeType_ = EMS_VALUE_BOOL_NOTSET; // Warm Water charge type (pump or 3-way-valve)
uint8_t wWDisinfectTemp_ = EMS_VALUE_UINT_NOTSET; // Warm Water disinfection temperature to prevent infection
uint8_t wWComfort_ = EMS_VALUE_UINT_NOTSET; // WW comfort mode
uint8_t wWActivated_ = EMS_VALUE_BOOL_NOTSET; // Warm Water activated
uint8_t wWSelTemp_ = EMS_VALUE_UINT_NOTSET; // Warm Water selected temperature
uint8_t wWCircPump_ = EMS_VALUE_BOOL_NOTSET; // Warm Water circulation pump available
uint8_t wWCircPumpMode_ = EMS_VALUE_UINT_NOTSET; // Warm Water circulation pump mode
uint8_t wWChargeType_ = EMS_VALUE_BOOL_NOTSET; // Warm Water charge type (pump or 3-way-valve)
uint8_t wWDisinfectionTemp_ = EMS_VALUE_UINT_NOTSET; // Warm Water disinfection temperature to prevent infection
uint8_t wWComfort_ = EMS_VALUE_UINT_NOTSET; // WW comfort mode
// MC10Status
uint16_t wwMixTemperature_ = EMS_VALUE_USHORT_NOTSET; // mengertemperatuur
uint16_t wwBufferBoilerTemperature_ = EMS_VALUE_USHORT_NOTSET; // bufferboilertemperature
// UBAMonitorFast - 0x18 on EMS1
uint8_t selFlowTemp_ = EMS_VALUE_UINT_NOTSET; // Selected flow temperature
uint16_t curFlowTemp_ = EMS_VALUE_USHORT_NOTSET; // Current flow temperature
uint16_t wwStorageTemp1_ = EMS_VALUE_USHORT_NOTSET; // warm water storage temp 1
uint16_t wwStorageTemp2_ = EMS_VALUE_USHORT_NOTSET; // warm water storage temp 2
uint16_t retTemp_ = EMS_VALUE_USHORT_NOTSET; // Return temperature
uint8_t burnGas_ = EMS_VALUE_BOOL_NOTSET; // Gas on/off
uint8_t fanWork_ = EMS_VALUE_BOOL_NOTSET; // Fan on/off
uint8_t ignWork_ = EMS_VALUE_BOOL_NOTSET; // Ignition on/off
uint8_t heatPmp_ = EMS_VALUE_BOOL_NOTSET; // Boiler pump on/off
uint8_t wWHeat_ = EMS_VALUE_BOOL_NOTSET; // 3-way valve on WW
uint8_t wWCirc_ = EMS_VALUE_BOOL_NOTSET; // Circulation on/off
uint8_t selBurnPow_ = EMS_VALUE_UINT_NOTSET; // Burner max power %
uint8_t curBurnPow_ = EMS_VALUE_UINT_NOTSET; // Burner current power %
uint16_t flameCurr_ = EMS_VALUE_USHORT_NOTSET; // Flame current in micro amps
uint8_t sysPress_ = EMS_VALUE_UINT_NOTSET; // System pressure
char serviceCodeChar_[3] = {'\0'}; // 2 character status/service code
uint16_t serviceCode_ = EMS_VALUE_USHORT_NOTSET; // error/service code
uint8_t boilerState_ = EMS_VALUE_BOOL_NOTSET; // State flag, used on HT3
uint8_t selFlowTemp_ = EMS_VALUE_UINT_NOTSET; // Selected flow temperature
uint16_t curFlowTemp_ = EMS_VALUE_USHORT_NOTSET; // Current flow temperature
uint16_t wwStorageTemp1_ = EMS_VALUE_USHORT_NOTSET; // warm water storage temp 1
uint16_t wwStorageTemp2_ = EMS_VALUE_USHORT_NOTSET; // warm water storage temp 2
uint16_t retTemp_ = EMS_VALUE_USHORT_NOTSET; // Return temperature
uint8_t burnGas_ = EMS_VALUE_BOOL_NOTSET; // Gas on/off
uint8_t fanWork_ = EMS_VALUE_BOOL_NOTSET; // Fan on/off
uint8_t ignWork_ = EMS_VALUE_BOOL_NOTSET; // Ignition on/off
uint8_t heatPump_ = EMS_VALUE_BOOL_NOTSET; // Boiler pump on/off
uint8_t wWHeat_ = EMS_VALUE_BOOL_NOTSET; // 3-way valve on WW
uint8_t wWCirc_ = EMS_VALUE_BOOL_NOTSET; // Circulation on/off
uint8_t selBurnPow_ = EMS_VALUE_UINT_NOTSET; // Burner max power %
uint8_t curBurnPow_ = EMS_VALUE_UINT_NOTSET; // Burner current power %
uint16_t flameCurr_ = EMS_VALUE_USHORT_NOTSET; // Flame current in micro amps
uint8_t sysPress_ = EMS_VALUE_UINT_NOTSET; // System pressure
char serviceCode_[3] = {'\0'}; // 2 character status/service code
uint16_t serviceCodeNumber_ = EMS_VALUE_USHORT_NOTSET; // error/service code
uint8_t boilerState_ = EMS_VALUE_BOOL_NOTSET; // State flag, used on HT3
// UBAMonitorSlow - 0x19 on EMS1
int16_t extTemp_ = EMS_VALUE_SHORT_NOTSET; // Outside temperature
int16_t outdoorTemp_ = EMS_VALUE_SHORT_NOTSET; // Outside temperature
uint16_t boilTemp_ = EMS_VALUE_USHORT_NOTSET; // Boiler temperature
uint16_t exhaustTemp_ = EMS_VALUE_USHORT_NOTSET; // Exhaust temperature
uint8_t pumpMod_ = EMS_VALUE_UINT_NOTSET; // Pump modulation %
@@ -109,44 +110,44 @@ class Boiler : public EMSdevice {
uint16_t switchTemp_ = EMS_VALUE_USHORT_NOTSET; // Switch temperature
// UBAMonitorWW
uint8_t wWSetTmp_ = EMS_VALUE_UINT_NOTSET; // Warm Water set temperature
uint16_t wWCurTmp_ = EMS_VALUE_USHORT_NOTSET; // Warm Water current temperature
uint16_t wWCurTmp2_ = EMS_VALUE_USHORT_NOTSET; // Warm Water current temperature storage
uint32_t wWStarts_ = EMS_VALUE_ULONG_NOTSET; // Warm Water # starts
uint32_t wWWorkM_ = EMS_VALUE_ULONG_NOTSET; // Warm Water # minutes
uint8_t wWOneTime_ = EMS_VALUE_BOOL_NOTSET; // Warm Water one time function on/off
uint8_t wWDisinfecting_ = EMS_VALUE_BOOL_NOTSET; // Warm Water disinfection on/off
uint8_t wWCharging_ = EMS_VALUE_BOOL_NOTSET; // Warm Water charging on/off
uint8_t wWRecharging_ = EMS_VALUE_BOOL_NOTSET; // Warm Water recharge on/off
uint8_t wWTemperatureOK_ = EMS_VALUE_BOOL_NOTSET; // Warm Water temperature ok on/off
uint8_t wWCurFlow_ = EMS_VALUE_UINT_NOTSET; // Warm Water current flow temp in l/min
uint8_t wWType_ = EMS_VALUE_UINT_NOTSET; // 0-off, 1-flow, 2-flowbuffer, 3-buffer, 4-layered buffer
uint8_t wWActive_ = EMS_VALUE_BOOL_NOTSET;
uint8_t wWSetTemp_ = EMS_VALUE_UINT_NOTSET; // Warm Water set temperature
uint16_t wWCurTemp_ = EMS_VALUE_USHORT_NOTSET; // Warm Water current temperature
uint16_t wWCurTemp2_ = EMS_VALUE_USHORT_NOTSET; // Warm Water current temperature storage
uint32_t wWStarts_ = EMS_VALUE_ULONG_NOTSET; // Warm Water # starts
uint32_t wWWorkM_ = EMS_VALUE_ULONG_NOTSET; // Warm Water # minutes
uint8_t wWOneTime_ = EMS_VALUE_BOOL_NOTSET; // Warm Water one time function on/off
uint8_t wWDisinfecting_ = EMS_VALUE_BOOL_NOTSET; // Warm Water disinfection on/off
uint8_t wWCharging_ = EMS_VALUE_BOOL_NOTSET; // Warm Water charging on/off
uint8_t wWRecharging_ = EMS_VALUE_BOOL_NOTSET; // Warm Water recharge on/off
uint8_t wWTempOK_ = EMS_VALUE_BOOL_NOTSET; // Warm Water temperature ok on/off
uint8_t wWCurFlow_ = EMS_VALUE_UINT_NOTSET; // Warm Water current flow temp in l/min
uint8_t wWType_ = EMS_VALUE_UINT_NOTSET; // 0-off, 1-flow, 2-flowbuffer, 3-buffer, 4-layered buffer
uint8_t wWActive_ = EMS_VALUE_BOOL_NOTSET;
// UBATotalUptime
uint32_t UBAuptime_ = EMS_VALUE_ULONG_NOTSET; // Total UBA working hours
// UBAParameters
uint8_t heating_activated_ = EMS_VALUE_BOOL_NOTSET; // Heating activated on the boiler
uint8_t heating_temp_ = EMS_VALUE_UINT_NOTSET; // Heating temperature setting on the boiler
uint8_t pump_mod_max_ = EMS_VALUE_UINT_NOTSET; // Boiler circuit pump modulation max. power %
uint8_t pump_mod_min_ = EMS_VALUE_UINT_NOTSET; // Boiler circuit pump modulation min. power
uint8_t burnPowermin_ = EMS_VALUE_UINT_NOTSET;
uint8_t burnPowermax_ = EMS_VALUE_UINT_NOTSET;
int8_t boilTemp_off_ = EMS_VALUE_INT_NOTSET;
int8_t boilTemp_on_ = EMS_VALUE_INT_NOTSET;
uint8_t burnPeriod_ = EMS_VALUE_UINT_NOTSET;
uint8_t pumpDelay_ = EMS_VALUE_UINT_NOTSET;
uint8_t heatingActivated_ = EMS_VALUE_BOOL_NOTSET; // Heating activated on the boiler
uint8_t heatingTemp_ = EMS_VALUE_UINT_NOTSET; // Heating temperature setting on the boiler
uint8_t pumpModMax_ = EMS_VALUE_UINT_NOTSET; // Boiler circuit pump modulation max. power %
uint8_t pumpModMin_ = EMS_VALUE_UINT_NOTSET; // Boiler circuit pump modulation min. power
uint8_t burnMinPower_ = EMS_VALUE_UINT_NOTSET;
uint8_t burnMaxPower_ = EMS_VALUE_UINT_NOTSET;
int8_t boilHystOff_ = EMS_VALUE_INT_NOTSET;
int8_t boilHystOn_ = EMS_VALUE_INT_NOTSET;
uint8_t burnMinPeriod_ = EMS_VALUE_UINT_NOTSET;
uint8_t pumpDelay_ = EMS_VALUE_UINT_NOTSET;
// UBASetPoint
uint8_t setFlowTemp_ = EMS_VALUE_UINT_NOTSET; // boiler setpoint temp
uint8_t setBurnPow_ = EMS_VALUE_UINT_NOTSET; // max output power in %
uint8_t setWWPumpPow_ = EMS_VALUE_UINT_NOTSET; // ww pump speed/power?
uint8_t setFlowTemp_ = EMS_VALUE_UINT_NOTSET; // boiler setpoint temp
uint8_t setBurnPow_ = EMS_VALUE_UINT_NOTSET; // max output power in %
uint8_t wWSetPumpPower_ = EMS_VALUE_UINT_NOTSET; // ww pump speed/power?
// other internal calculated params
uint8_t tap_water_active_ = EMS_VALUE_BOOL_NOTSET; // Hot tap water is on/off
uint8_t heating_active_ = EMS_VALUE_BOOL_NOTSET; // Central heating is on/off
uint8_t pumpMod2_ = EMS_VALUE_UINT_NOTSET; // heatpump modulation from 0xE3 (heatpumps)
uint8_t tapwaterActive_ = EMS_VALUE_BOOL_NOTSET; // Hot tap water is on/off
uint8_t heatingActive_ = EMS_VALUE_BOOL_NOTSET; // Central heating is on/off
uint8_t pumpMod2_ = EMS_VALUE_UINT_NOTSET; // heatpump modulation from 0xE3 (heatpumps)
bool command_info(const char * value, const int8_t id, JsonObject & output);