mirror of
https://github.com/emsesp/EMS-ESP32.git
synced 2025-12-15 12:19:58 +03:00
added IP and version to MQTT start payload, added support for RC100/Moduline 1010, Fixed Junkers thermostat writing
This commit is contained in:
11
CHANGELOG.md
11
CHANGELOG.md
@@ -9,16 +9,18 @@ and this project adheres to [Semantic Versioning](https://semver.org/spec/v2.0.0
|
||||
|
||||
### Added
|
||||
- Solar Module SM200 support
|
||||
- `set master_thermostat <product id>` to choose with thermostat is master when there are multiple on the bus
|
||||
- Support writing to Junkers FR100 thermostats
|
||||
- Support writing to RC100, Moduline 1000/1010 thermostats
|
||||
- MM10 Mixing module support (thanks @MichaelDvP)
|
||||
- MM200 warm water circuits (https://github.com/proddy/EMS-ESP/pull/315)
|
||||
- First implementation of writing to Junker Thermostats (thanks @Neonox31)
|
||||
- Support for Moduline 200 and Sieger ES72 thermostats
|
||||
- First implementation of writing to generic Junker Thermostats (thanks @Neonox31)
|
||||
- Added model type (Buderus, Sieger, Junkers, Nefit, Bosch, Worcester) to device names
|
||||
- `set master_thermostat <product id>` to choose with thermostat is master when there are multiple on the bus
|
||||
- `boiler wwonetime` command from Telnet
|
||||
- `set bus_id <ID>` to support multiple EMS-ESP circuits. Default is 0x0B to mimic a service key.
|
||||
- `mqtt_nestedjson` option to disable multiple data records being nested into a single JSON string
|
||||
- MQTT publish messages are queued and gracefully published every second to avoid TCP blocks
|
||||
- Added `mqtt_nestedjson` option to disable multiple data records being nested into a single JSON string
|
||||
- Support for Moduline 200 and Sieger ES72 thermostats
|
||||
- Added features to WW messages (0x33, 0x34) to improve WW monitoring. (PR#338 by @ypaindaveine)
|
||||
- Added mixing log and stub for EMS type 0xAC (PR#338 by @ypaindaveine)
|
||||
|
||||
@@ -31,6 +33,7 @@ and this project adheres to [Semantic Versioning](https://semver.org/spec/v2.0.0
|
||||
- improved MQTT publishing to stop network flooding. `publish_time` of -1 is no publish, 0 is automatic otherwise its a time interval
|
||||
- External sensors (like Dallas DS18*) are sent as a nested MQTT topic including their unqiue identifier
|
||||
- `mqttlog` console command renamed to `mqttqueue` to only show the current publish queue
|
||||
- `status` payload on start-up shows the IP and Version of EMS-ESP
|
||||
|
||||
### Removed
|
||||
- `autodetect scan`
|
||||
|
||||
Reference in New Issue