@@ -74,17 +74,13 @@ Boiler::Boiler(uint8_t device_type, int8_t device_id, uint8_t product_id, const
|
||||
|
||||
// create the config topics for Home Assistant MQTT Discovery
|
||||
// for each of the main elements
|
||||
void Boiler::register_mqtt_ha_config(bool force) {
|
||||
if ((mqtt_ha_config_ && !force)) {
|
||||
return;
|
||||
}
|
||||
|
||||
void Boiler::register_mqtt_ha_config() {
|
||||
if (!Mqtt::connected()) {
|
||||
return;
|
||||
}
|
||||
|
||||
// Create the Master device
|
||||
StaticJsonDocument<EMSESP_MAX_JSON_SIZE_MEDIUM> doc;
|
||||
StaticJsonDocument<EMSESP_MAX_JSON_SIZE_SMALL> doc;
|
||||
doc["name"] = F("Service Code");
|
||||
doc["uniq_id"] = F("boiler");
|
||||
doc["ic"] = F("mdi:home-thermometer-outline");
|
||||
@@ -141,8 +137,17 @@ void Boiler::register_mqtt_ha_config(bool force) {
|
||||
Mqtt::register_mqtt_ha_sensor(nullptr, nullptr, F_(burnWorkMin), this->device_type(), "burnWorkMin", F_(min), nullptr);
|
||||
Mqtt::register_mqtt_ha_sensor(nullptr, nullptr, F_(heatWorkMin), this->device_type(), "heatWorkMin", F_(min), nullptr);
|
||||
Mqtt::register_mqtt_ha_sensor(nullptr, nullptr, F_(UBAuptime), this->device_type(), "UBAuptime", F_(min), nullptr);
|
||||
mqtt_ha_config_ = true; // done
|
||||
}
|
||||
|
||||
// ww
|
||||
// create the config topics for Home Assistant MQTT Discovery
|
||||
// for each of the ww elements
|
||||
void Boiler::register_mqtt_ha_config_ww() {
|
||||
|
||||
if (!Mqtt::connected()) {
|
||||
return;
|
||||
}
|
||||
// ww
|
||||
Mqtt::register_mqtt_ha_sensor(nullptr, F_(mqtt_suffix_ww), F_(wWSelTemp), this->device_type(), "wWSelTemp", F_(degrees), F_(iconcruise));
|
||||
Mqtt::register_mqtt_ha_sensor(nullptr, F_(mqtt_suffix_ww), F_(wWSetTemp), this->device_type(), "wWSetTemp", F_(degrees), F_(icontemperature));
|
||||
Mqtt::register_mqtt_ha_sensor(nullptr, F_(mqtt_suffix_ww), F_(wWDisinfectionTemp), this->device_type(), "wWDisinfectionTemp", F_(degrees), F_(icontemperature));
|
||||
@@ -170,14 +175,15 @@ void Boiler::register_mqtt_ha_config(bool force) {
|
||||
Mqtt::register_mqtt_ha_sensor(nullptr, F_(mqtt_suffix_ww), F_(wWStarts), this->device_type(), "wWStarts", nullptr, nullptr);
|
||||
Mqtt::register_mqtt_ha_sensor(nullptr, F_(mqtt_suffix_ww), F_(wWWorkM), this->device_type(), "wWWorkM", F_(min), nullptr);
|
||||
|
||||
mqtt_ha_config_ = true; // done
|
||||
mqtt_ha_config_ww_ = true; // done
|
||||
}
|
||||
|
||||
// send stuff to the Web UI
|
||||
void Boiler::device_info_web(JsonArray & root) {
|
||||
// fetch the values into a JSON document
|
||||
DynamicJsonDocument doc(EMSESP_MAX_JSON_SIZE_LARGE);
|
||||
JsonObject json = doc.to<JsonObject>();
|
||||
// DynamicJsonDocument doc(EMSESP_MAX_JSON_SIZE_LARGE);
|
||||
StaticJsonDocument<EMSESP_MAX_JSON_SIZE_LARGE> doc;
|
||||
JsonObject json = doc.to<JsonObject>();
|
||||
if (!export_values_main(json)) {
|
||||
return; // empty
|
||||
}
|
||||
@@ -618,19 +624,29 @@ bool Boiler::export_values_main(JsonObject & json) {
|
||||
void Boiler::publish_values(JsonObject & json, bool force) {
|
||||
// handle HA first
|
||||
if (Mqtt::mqtt_format() == Mqtt::Format::HA) {
|
||||
register_mqtt_ha_config(force);
|
||||
if (force) {
|
||||
mqtt_ha_config_ = false;
|
||||
mqtt_ha_config_ww_ = false;
|
||||
}
|
||||
// register ww in next cycle if both unregistered
|
||||
if (!mqtt_ha_config_) {
|
||||
register_mqtt_ha_config();
|
||||
return;
|
||||
} else if (!mqtt_ha_config_ww_) {
|
||||
register_mqtt_ha_config_ww();
|
||||
return;
|
||||
}
|
||||
}
|
||||
|
||||
DynamicJsonDocument doc_main(EMSESP_MAX_JSON_SIZE_LARGE);
|
||||
JsonObject json_main = doc_main.to<JsonObject>();
|
||||
if (export_values_main(json_main)) {
|
||||
Mqtt::publish(F("boiler_data"), doc_main.as<JsonObject>());
|
||||
StaticJsonDocument<EMSESP_MAX_JSON_SIZE_LARGE> doc;
|
||||
JsonObject json_data = doc.to<JsonObject>();
|
||||
if (export_values_main(json_data)) {
|
||||
Mqtt::publish(F("boiler_data"), json_data);
|
||||
}
|
||||
json_data.clear();
|
||||
|
||||
DynamicJsonDocument doc_ww(EMSESP_MAX_JSON_SIZE_LARGE);
|
||||
JsonObject json_ww = doc_ww.to<JsonObject>();
|
||||
if (export_values_ww(json_ww)) {
|
||||
Mqtt::publish(F("boiler_data_ww"), doc_ww.as<JsonObject>());
|
||||
if (export_values_ww(json_data)) {
|
||||
Mqtt::publish(F("boiler_data_ww"), json_data);
|
||||
}
|
||||
|
||||
// send out heating and tapwater status
|
||||
@@ -651,13 +667,14 @@ void Boiler::show_values(uuid::console::Shell & shell) {
|
||||
EMSdevice::show_values(shell); // for showing the header
|
||||
|
||||
// fetch the values into a JSON document
|
||||
DynamicJsonDocument doc(EMSESP_MAX_JSON_SIZE_LARGE);
|
||||
JsonObject json = doc.to<JsonObject>();
|
||||
// DynamicJsonDocument doc(EMSESP_MAX_JSON_SIZE_LARGE);
|
||||
StaticJsonDocument<EMSESP_MAX_JSON_SIZE_LARGE> doc;
|
||||
JsonObject json = doc.to<JsonObject>();
|
||||
if (!export_values_main(json)) {
|
||||
return; // empty
|
||||
}
|
||||
export_values_ww(json); // append ww values
|
||||
doc.shrinkToFit();
|
||||
// doc.shrinkToFit();
|
||||
|
||||
print_value_json(shell, F("heatingActive"), nullptr, F_(heatingActive), nullptr, json);
|
||||
print_value_json(shell, F("tapwaterActive"), nullptr, F_(tapwaterActive), nullptr, json);
|
||||
|
||||