extended verbose mode

This commit is contained in:
proddy
2018-06-06 17:56:17 +02:00
parent adce66e4bb
commit 15a6aed200

View File

@@ -45,7 +45,7 @@ Ticker showerResetTimer;
#define PROJECT_CMDS \
"* s=show statistics\n\r" \
"* P=publish stats to MQTT\n\r" \
"* v=Verbose mode on/off\n\r" \
"* v [n] set logging to 0=none, 1=basic, 2=verbose\n\r" \
"* p=Poll response on/off\n\r" \
"* T=Thermostat Support on/off\n\r" \
"* S=Shower Timer on/off\n\r" \
@@ -70,6 +70,7 @@ Ticker showerResetTimer;
#define TOPIC_THERMOSTAT_TEMP MQTT_BOILER "thermostat_temp" // for received thermostat temp changes
#define TOPIC_THERMOSTAT_CURRTEMP MQTT_BOILER "thermostat_currtemp" // current temperature
#define TOPIC_THERMOSTAT_SELTEMP MQTT_BOILER "thermostat_seltemp" // selected temperature
#define TOPIC_THERMOSTAT_MODE MQTT_BOILER "thermostat_mode" // selected temperature
#define TOPIC_BOILER_DATA MQTT_BOILER "boiler_data" // for sending boiler values
#define TOPIC_SHOWERTIME MQTT_BOILER "showertime" // for sending shower time results
@@ -108,8 +109,7 @@ netInfo homeNet = {.mqttHost = MQTT_IP,
.mqttPass = MQTT_PASS,
.mqttPort = 1883, // this is the default, change if using another port
.ssid = WIFI_SSID,
.pass = WIFI_PASSWORD
};
.pass = WIFI_PASSWORD};
ESPHelper myESP(&homeNet);
@@ -134,7 +134,8 @@ void showInfo() {
// General stats from EMS bus
myDebug("EMS Bus stats:\n");
myDebug(" Poll is %s, Shower is %s, Shower timer is %s, RxPgks=%d, TxPkgs=%d, #CrcErrors=%d",
myDebug(" Thermostat is %s, Poll is %s, Shower is %s, Shower timer is %s, RxPgks=%d, TxPkgs=%d, #CrcErrors=%d",
((Boiler_Status.thermostat_enabled) ? "enabled" : "disabled"),
((EMS_Sys_Status.emsPollEnabled) ? "enabled" : "disabled"),
((Boiler_Status.shower_enabled) ? "enabled" : "disabled"),
((Boiler_Status.shower_timer) ? "enabled" : "disabled"),
@@ -298,6 +299,16 @@ void publishValues() {
myESP.publish(TOPIC_THERMOSTAT_CURRTEMP, _float_to_char(s, EMS_Thermostat.curr_roomTemp));
myESP.publish(TOPIC_THERMOSTAT_SELTEMP, _float_to_char(s, EMS_Thermostat.setpoint_roomTemp));
// send mode 0=low, 1=manual, 2=clock/auto
if (EMS_Thermostat.mode == 0) {
myESP.publish(TOPIC_THERMOSTAT_MODE, "low");
} else if (EMS_Thermostat.mode == 1) {
myESP.publish(TOPIC_THERMOSTAT_MODE, "manual");
} else {
myESP.publish(TOPIC_THERMOSTAT_MODE, "auto");
}
myESP.publish(TOPIC_THERMOSTAT_SELTEMP, _float_to_char(s, EMS_Thermostat.setpoint_roomTemp));
}
}
@@ -330,8 +341,7 @@ void myDebugCallback() {
ems_setWarmWaterTemp((uint8_t)strtol(&cmd[2], 0, 10));
break;
case 'v': // verbose
b = !ems_getLogVerbose();
ems_setLogVerbose(b);
ems_setLogging((_EMS_SYS_LOGGING)(cmd[2] - '0'));
break;
case 'a': // set ww activate on or off
if ((cmd[2] - '0') == 1)
@@ -562,7 +572,7 @@ void loop() {
} else {
// check if the shower has been on too long
if ((((timestamp - Boiler_Shower.timerStart) > SHOWER_MAX_DURATION) && !Boiler_Shower.isColdShot)
&& Boiler_Status.shower_timer) {
&& Boiler_Status.shower_timer) {
_showerColdShotStart();
// start the timer for n seconds which will reset the water back to hot
showerResetTimer.attach(SHOWER_OFF_DURATION, _showerColdShotStop);