register thermostat with Homeassistant discovery when a new heating circuit is detected
This commit is contained in:
@@ -144,7 +144,7 @@ Thermostat::Thermostat(uint8_t device_type, uint8_t device_id, uint8_t product_i
|
||||
if (((num_devices == 1) && (actual_master_thermostat == EMSESP_DEFAULT_MASTER_THERMOSTAT) && ((device_id == 0x10) || (device_id == 0x17)))
|
||||
|| (master_thermostat == device_id)) {
|
||||
EMSESP::actual_master_thermostat(device_id);
|
||||
LOG_DEBUG(F("Registering new thermostat with device ID 0x%02X (as the master)"), device_id);
|
||||
LOG_DEBUG(F("Registering new thermostat with device ID 0x%02X (as master)"), device_id);
|
||||
init_mqtt();
|
||||
} else {
|
||||
LOG_DEBUG(F("Registering new thermostat with device ID 0x%02X"), device_id);
|
||||
@@ -162,71 +162,11 @@ Thermostat::Thermostat(uint8_t device_type, uint8_t device_id, uint8_t product_i
|
||||
}
|
||||
|
||||
// for the master thermostat initialize the MQTT subscribes
|
||||
// these will be prefixed with hostname
|
||||
void Thermostat::init_mqtt() {
|
||||
register_mqtt_topic("thermostat_cmd", std::bind(&Thermostat::thermostat_cmd, this, _1)); // generic commands
|
||||
|
||||
// if the MQTT format type is ha then send the config to HA (via the mqtt discovery service)
|
||||
// for each of the heating circuits
|
||||
// state is /state
|
||||
// config is /config
|
||||
if (mqtt_format_ == MQTT_format::HA) {
|
||||
for (uint8_t hc = 0; hc < monitor_typeids.size(); hc++) {
|
||||
StaticJsonDocument<EMSESP_MAX_JSON_SIZE_MEDIUM> doc;
|
||||
uint8_t hc_num = hc + 1;
|
||||
|
||||
std::string hc_text(10, '\0');
|
||||
snprintf_P(&hc_text[0], hc_text.capacity() + 1, PSTR("hc%d"), hc_num);
|
||||
doc["name"] = hc_text;
|
||||
doc["uniq_id"] = hc_text;
|
||||
|
||||
// topic root is homeassistant/climate/ems-esp/hc<1..n>/
|
||||
std::string root(100, '\0');
|
||||
snprintf_P(&root[0], root.capacity() + 1, PSTR("homeassistant/climate/ems-esp/hc%d"), hc_num);
|
||||
doc["~"] = root;
|
||||
|
||||
doc["mode_cmd_t"] = "~/cmd_mode";
|
||||
doc["mode_stat_t"] = "~/state";
|
||||
doc["temp_cmd_t"] = "~/cmd_temp";
|
||||
doc["temp_stat_t"] = "~/state";
|
||||
doc["curr_temp_t"] = "~/state";
|
||||
|
||||
std::string mode_str(30, '\0');
|
||||
snprintf_P(&mode_str[0], 30, PSTR("{{value_json.hc%d.mode}}"), hc_num);
|
||||
doc["mode_stat_tpl"] = mode_str;
|
||||
|
||||
std::string seltemp_str(30, '\0');
|
||||
snprintf_P(&seltemp_str[0], 30, PSTR("{{value_json.hc%d.seltemp}}"), hc_num);
|
||||
doc["temp_stat_tpl"] = seltemp_str;
|
||||
|
||||
std::string currtemp_str(30, '\0');
|
||||
snprintf_P(&currtemp_str[0], 30, PSTR("{{value_json.hc%d.currtemp}}"), hc_num);
|
||||
doc["curr_temp_tpl"] = currtemp_str;
|
||||
|
||||
doc["min_temp"] = "5";
|
||||
doc["max_temp"] = "40";
|
||||
doc["temp_step"] = "0.5";
|
||||
|
||||
JsonArray modes = doc.createNestedArray("modes");
|
||||
modes.add("off");
|
||||
modes.add("heat");
|
||||
modes.add("auto");
|
||||
|
||||
std::string topic(100, '\0'); // e.g homeassistant/climate/hc1/thermostat/config
|
||||
snprintf_P(&topic[0], topic.capacity() + 1, PSTR("homeassistant/climate/ems-esp/hc%d/config"), hc_num);
|
||||
// Mqtt::publish(topic); // empty payload, this remove any previous config sent to HA
|
||||
Mqtt::publish(topic, doc, true); // publish the config payload with retain flag
|
||||
|
||||
// subscribe to the temp and mode commands
|
||||
snprintf_P(&topic[0], topic.capacity() + 1, PSTR("homeassistant/climate/ems-esp/hc%d/cmd_temp"), hc_num);
|
||||
register_mqtt_topic(topic, std::bind(&Thermostat::thermostat_cmd_temp, this, _1));
|
||||
snprintf_P(&topic[0], topic.capacity() + 1, PSTR("homeassistant/climate/ems-esp/hc%d/cmd_mode"), hc_num);
|
||||
register_mqtt_topic(topic, std::bind(&Thermostat::thermostat_cmd_mode, this, _1));
|
||||
}
|
||||
} else {
|
||||
// these will be prefixed with hostname and base
|
||||
register_mqtt_topic("thermostat_cmd_temp", std::bind(&Thermostat::thermostat_cmd_temp, this, _1));
|
||||
register_mqtt_topic("thermostat_cmd_mode", std::bind(&Thermostat::thermostat_cmd_mode, this, _1));
|
||||
}
|
||||
}
|
||||
|
||||
// only add the menu for the master thermostat
|
||||
@@ -808,6 +748,11 @@ std::shared_ptr<Thermostat::HeatingCircuit> Thermostat::heating_circuit(std::sha
|
||||
|
||||
std::sort(heating_circuits_.begin(), heating_circuits_.end()); // sort based on hc number
|
||||
|
||||
// if we're using Home Assistant and HA discovery, register the new config
|
||||
if (mqtt_format_ == MQTT_format::HA) {
|
||||
register_mqtt_ha_config(hc_num);
|
||||
}
|
||||
|
||||
// set the flag saying we want its data during the next auto fetch
|
||||
toggle_fetch(monitor_typeids[hc_num - 1], toggle_);
|
||||
toggle_fetch(set_typeids[hc_num - 1], toggle_);
|
||||
@@ -815,6 +760,62 @@ std::shared_ptr<Thermostat::HeatingCircuit> Thermostat::heating_circuit(std::sha
|
||||
return heating_circuits_.back(); // even after sorting, this should still point back to the newly created HC
|
||||
}
|
||||
|
||||
// publish config topic for HA MQTT Discovery
|
||||
// homeassistant/climate/ems-esp/hc<num>
|
||||
// state is /state
|
||||
// config is /config
|
||||
void Thermostat::register_mqtt_ha_config(uint8_t hc_num) {
|
||||
StaticJsonDocument<EMSESP_MAX_JSON_SIZE_MEDIUM> doc;
|
||||
|
||||
std::string hc_text(10, '\0');
|
||||
snprintf_P(&hc_text[0], hc_text.capacity() + 1, PSTR("hc%d"), hc_num);
|
||||
doc["name"] = hc_text;
|
||||
doc["uniq_id"] = hc_text;
|
||||
|
||||
// topic root is homeassistant/climate/ems-esp/hc<1..n>/
|
||||
std::string root(100, '\0');
|
||||
snprintf_P(&root[0], root.capacity() + 1, PSTR("homeassistant/climate/ems-esp/hc%d"), hc_num);
|
||||
doc["~"] = root;
|
||||
|
||||
doc["mode_cmd_t"] = "~/cmd_mode";
|
||||
doc["mode_stat_t"] = "~/state";
|
||||
doc["temp_cmd_t"] = "~/cmd_temp";
|
||||
doc["temp_stat_t"] = "~/state";
|
||||
doc["curr_temp_t"] = "~/state";
|
||||
|
||||
std::string mode_str(30, '\0');
|
||||
snprintf_P(&mode_str[0], 30, PSTR("{{value_json.hc%d.mode}}"), hc_num);
|
||||
doc["mode_stat_tpl"] = mode_str;
|
||||
|
||||
std::string seltemp_str(30, '\0');
|
||||
snprintf_P(&seltemp_str[0], 30, PSTR("{{value_json.hc%d.seltemp}}"), hc_num);
|
||||
doc["temp_stat_tpl"] = seltemp_str;
|
||||
|
||||
std::string currtemp_str(30, '\0');
|
||||
snprintf_P(&currtemp_str[0], 30, PSTR("{{value_json.hc%d.currtemp}}"), hc_num);
|
||||
doc["curr_temp_tpl"] = currtemp_str;
|
||||
|
||||
doc["min_temp"] = "5";
|
||||
doc["max_temp"] = "40";
|
||||
doc["temp_step"] = "0.5";
|
||||
|
||||
JsonArray modes = doc.createNestedArray("modes");
|
||||
modes.add("off");
|
||||
modes.add("heat");
|
||||
modes.add("auto");
|
||||
|
||||
std::string topic(100, '\0'); // e.g homeassistant/climate/hc1/thermostat/config
|
||||
snprintf_P(&topic[0], topic.capacity() + 1, PSTR("homeassistant/climate/ems-esp/hc%d/config"), hc_num);
|
||||
// Mqtt::publish(topic); // empty payload, this remove any previous config sent to HA
|
||||
Mqtt::publish(topic, doc, true); // publish the config payload with retain flag
|
||||
|
||||
// subscribe to the temp and mode commands
|
||||
snprintf_P(&topic[0], topic.capacity() + 1, PSTR("homeassistant/climate/ems-esp/hc%d/cmd_temp"), hc_num);
|
||||
register_mqtt_topic(topic, std::bind(&Thermostat::thermostat_cmd_temp, this, _1));
|
||||
snprintf_P(&topic[0], topic.capacity() + 1, PSTR("homeassistant/climate/ems-esp/hc%d/cmd_mode"), hc_num);
|
||||
register_mqtt_topic(topic, std::bind(&Thermostat::thermostat_cmd_mode, this, _1));
|
||||
}
|
||||
|
||||
// decodes the thermostat mode for the heating circuit based on the thermostat type
|
||||
// modes are off, manual, auto, day and night
|
||||
uint8_t Thermostat::HeatingCircuit::get_mode(uint8_t flags) const {
|
||||
@@ -1549,7 +1550,6 @@ void Thermostat::set_mode(const uint8_t mode, const uint8_t hc_num) {
|
||||
|
||||
default:
|
||||
case HeatingCircuit::Mode::AUTO:
|
||||
// case HeatingCircuit::Mode::HOLIDAY:
|
||||
case HeatingCircuit::Mode::ECO:
|
||||
set_mode_value = 2;
|
||||
break;
|
||||
@@ -1860,7 +1860,6 @@ void Thermostat::console_commands(Shell & shell, unsigned int context) {
|
||||
read_flash_string(F("eco")),
|
||||
read_flash_string(F("comfort")),
|
||||
read_flash_string(F("heat")),
|
||||
// read_flash_string(F("holiday")),
|
||||
read_flash_string(F("nofrost")),
|
||||
read_flash_string(F("auto"))
|
||||
|
||||
|
||||
@@ -212,6 +212,8 @@ class Thermostat : public EMSdevice {
|
||||
std::shared_ptr<Thermostat::HeatingCircuit> heating_circuit(std::shared_ptr<const Telegram> telegram);
|
||||
std::shared_ptr<Thermostat::HeatingCircuit> heating_circuit(const uint8_t hc_num);
|
||||
|
||||
void register_mqtt_ha_config(uint8_t hc_num);
|
||||
|
||||
void process_RCOutdoorTemp(std::shared_ptr<const Telegram> telegram);
|
||||
void process_IBASettings(std::shared_ptr<const Telegram> telegram);
|
||||
void process_RCTime(std::shared_ptr<const Telegram> telegram);
|
||||
|
||||
Reference in New Issue