@@ -36,7 +36,6 @@ class Boiler : public EMSdevice {
uint8_t boilerState_ = EMS_VALUE_UINT_NOTSET; // Boiler state flag - FOR INTERNAL USE
static constexpr uint8_t EMS_TYPE_UBASettingsWW = 0x26;
static constexpr uint8_t EMS_TYPE_UBAParameterWW = 0x33;
static constexpr uint8_t EMS_TYPE_UBAFunctionTest = 0x1D;
static constexpr uint8_t EMS_TYPE_UBAFlags = 0x35;
@@ -74,9 +73,8 @@ class Boiler : public EMSdevice {
uint8_t wWHeat_; // 3-way valve on WW
uint8_t wWSetPumpPower_; // ww pump speed/power?
uint8_t wWFlowTempOffset_; // Boiler offset for ww heating
uint8_t wWMaxPower_; // Warm Water maximum power
uint32_t wWStarts_; // Warm Water # starts
uint32_t wWStarts2_; // Warm water starts (control)
uint32_t wWStarts2_; // Warm water control starts
uint32_t wWWorkM_; // Warm Water # minutes
uint16_t mixerTemp_; // mixing temperature
@@ -128,8 +126,8 @@ class Boiler : public EMSdevice {
uint32_t upTimeCompHeating_; // Operating time compressor heating
uint32_t upTimeCompCooling_; // Operating time compressor cooling
uint32_t upTimeCompWw_; // Operating time compressor warm water
uint32_t heatingStarts_; // Heating starts (control)
uint32_t coolingStarts_; // Cooling starts (control)
uint32_t heatingStarts_; // Heating control starts
uint32_t coolingStarts_; // Cooling control starts
uint32_t nrgConsTotal_; // Energy consumption total
uint32_t nrgConsCompTotal_; // Energy consumption compressor total
uint32_t nrgConsCompHeating_; // Energy consumption compressor heating
@@ -169,7 +167,6 @@ class Boiler : public EMSdevice {
void process_UBAInformation(std::shared_ptr<const Telegram> telegram);
void process_UBAEnergySupplied(std::shared_ptr<const Telegram> telegram);
void process_CascadeMessage(std::shared_ptr<const Telegram> telegram);
void process_UBASettingsWW(std::shared_ptr<const Telegram> telegram);
// commands - none of these use the additional id parameter
bool set_warmwater_mode(const char * value, const int8_t id);
@@ -180,7 +177,6 @@ class Boiler : public EMSdevice {
bool set_warmwater_circulation_pump(const char * value, const int8_t id);
bool set_warmwater_circulation_mode(const char * value, const int8_t id);
bool set_warmwater_temp(const char * value, const int8_t id);
bool set_warmwater_maxpower(const char * value, const int8_t id);
bool set_wWFlowTempOffset(const char * value, const int8_t id);
bool set_flow_temp(const char * value, const int8_t id);
bool set_heating_activated(const char * value, const int8_t id);