mirror of
https://github.com/emsesp/EMS-ESP32.git
synced 2025-12-06 15:59:52 +03:00
add thermostat Rego 3000, TR120RF, heatpump modules, #917
This commit is contained in:
@@ -40,7 +40,7 @@
|
|||||||
{167, DeviceType::BOILER, "Cerapur Aero", DeviceFlags::EMS_DEVICE_FLAG_NONE},
|
{167, DeviceType::BOILER, "Cerapur Aero", DeviceFlags::EMS_DEVICE_FLAG_NONE},
|
||||||
{168, DeviceType::BOILER, "Hybrid Heatpump", DeviceFlags::EMS_DEVICE_FLAG_HYBRID},
|
{168, DeviceType::BOILER, "Hybrid Heatpump", DeviceFlags::EMS_DEVICE_FLAG_HYBRID},
|
||||||
{170, DeviceType::BOILER, "Logano GB212", DeviceFlags::EMS_DEVICE_FLAG_NONE},
|
{170, DeviceType::BOILER, "Logano GB212", DeviceFlags::EMS_DEVICE_FLAG_NONE},
|
||||||
{172, DeviceType::BOILER, "Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i", DeviceFlags::EMS_DEVICE_FLAG_HEATPUMP},
|
{172, DeviceType::BOILER, "Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i", DeviceFlags::EMS_DEVICE_FLAG_HEATPUMP},
|
||||||
{173, DeviceType::BOILER, "Geo 5xx", DeviceFlags::EMS_DEVICE_FLAG_HEATPUMP},
|
{173, DeviceType::BOILER, "Geo 5xx", DeviceFlags::EMS_DEVICE_FLAG_HEATPUMP},
|
||||||
{195, DeviceType::BOILER, "Condens 5000i/Greenstar 8000/GC9800IW", DeviceFlags::EMS_DEVICE_FLAG_NONE},
|
{195, DeviceType::BOILER, "Condens 5000i/Greenstar 8000/GC9800IW", DeviceFlags::EMS_DEVICE_FLAG_NONE},
|
||||||
{203, DeviceType::BOILER, "Logamax U122/Cerapur", DeviceFlags::EMS_DEVICE_FLAG_NONE},
|
{203, DeviceType::BOILER, "Logamax U122/Cerapur", DeviceFlags::EMS_DEVICE_FLAG_NONE},
|
||||||
@@ -98,6 +98,7 @@
|
|||||||
{172, DeviceType::THERMOSTAT, "Rego 2000/3000", DeviceFlags::EMS_DEVICE_FLAG_RC300}, // 0x10
|
{172, DeviceType::THERMOSTAT, "Rego 2000/3000", DeviceFlags::EMS_DEVICE_FLAG_RC300}, // 0x10
|
||||||
{216, DeviceType::THERMOSTAT, "CRF200S", DeviceFlags::EMS_DEVICE_FLAG_CRF | DeviceFlags::EMS_DEVICE_FLAG_NO_WRITE}, // 0x18
|
{216, DeviceType::THERMOSTAT, "CRF200S", DeviceFlags::EMS_DEVICE_FLAG_CRF | DeviceFlags::EMS_DEVICE_FLAG_NO_WRITE}, // 0x18
|
||||||
{246, DeviceType::THERMOSTAT, "Comfort+2RF", DeviceFlags::EMS_DEVICE_FLAG_CRF | DeviceFlags::EMS_DEVICE_FLAG_NO_WRITE}, // 0x18
|
{246, DeviceType::THERMOSTAT, "Comfort+2RF", DeviceFlags::EMS_DEVICE_FLAG_CRF | DeviceFlags::EMS_DEVICE_FLAG_NO_WRITE}, // 0x18
|
||||||
|
{253, DeviceType::THERMOSTAT, "Rego 3000", DeviceFlags::EMS_DEVICE_FLAG_RC300}, // 0x10
|
||||||
|
|
||||||
// Thermostat - Sieger - 0x10 / 0x17
|
// Thermostat - Sieger - 0x10 / 0x17
|
||||||
{ 66, DeviceType::THERMOSTAT, "ES72/RC20", DeviceFlags::EMS_DEVICE_FLAG_RC20_N}, // 0x17 or remote
|
{ 66, DeviceType::THERMOSTAT, "ES72/RC20", DeviceFlags::EMS_DEVICE_FLAG_RC20_N}, // 0x17 or remote
|
||||||
@@ -120,6 +121,7 @@
|
|||||||
// Thermostat remote - 0x38
|
// Thermostat remote - 0x38
|
||||||
{ 3, DeviceType::THERMOSTAT, "RT800", DeviceFlags::EMS_DEVICE_FLAG_RC100H},
|
{ 3, DeviceType::THERMOSTAT, "RT800", DeviceFlags::EMS_DEVICE_FLAG_RC100H},
|
||||||
{200, DeviceType::THERMOSTAT, "RC100H", DeviceFlags::EMS_DEVICE_FLAG_RC100H},
|
{200, DeviceType::THERMOSTAT, "RC100H", DeviceFlags::EMS_DEVICE_FLAG_RC100H},
|
||||||
|
{249, DeviceType::THERMOSTAT, "TR120RF", DeviceFlags::EMS_DEVICE_FLAG_RC100H},
|
||||||
|
|
||||||
// Solar Modules - 0x30 (for solar), 0x2A, 0x41 (for ww)
|
// Solar Modules - 0x30 (for solar), 0x2A, 0x41 (for ww)
|
||||||
{ 73, DeviceType::SOLAR, "SM10", DeviceFlags::EMS_DEVICE_FLAG_SM10},
|
{ 73, DeviceType::SOLAR, "SM10", DeviceFlags::EMS_DEVICE_FLAG_SM10},
|
||||||
@@ -140,6 +142,7 @@
|
|||||||
{204, DeviceType::MIXER, "MP100", DeviceFlags::EMS_DEVICE_FLAG_MP}, // pool
|
{204, DeviceType::MIXER, "MP100", DeviceFlags::EMS_DEVICE_FLAG_MP}, // pool
|
||||||
|
|
||||||
// Heat Pumps - 0x38? This is a thermostat like RC100H
|
// Heat Pumps - 0x38? This is a thermostat like RC100H
|
||||||
|
// also prod-id of wifi module and wireless base
|
||||||
{252, DeviceType::HEATPUMP, "HP Module", DeviceFlags::EMS_DEVICE_FLAG_NONE},
|
{252, DeviceType::HEATPUMP, "HP Module", DeviceFlags::EMS_DEVICE_FLAG_NONE},
|
||||||
|
|
||||||
// Heat Pumps - 0x53
|
// Heat Pumps - 0x53
|
||||||
|
|||||||
@@ -1021,10 +1021,20 @@ bool EMSESP::add_device(const uint8_t device_id, const uint8_t product_id, const
|
|||||||
}
|
}
|
||||||
} else if (device.device_type == DeviceType::HEATSOURCE) {
|
} else if (device.device_type == DeviceType::HEATSOURCE) {
|
||||||
device_p = &device;
|
device_p = &device;
|
||||||
if (device_id == EMSdevice::EMS_DEVICE_ID_BOILER) { // AHS as only heatsource on d 0x08
|
if (device_id == EMSdevice::EMS_DEVICE_ID_BOILER) { // AHS as only heatsource on id 0x08
|
||||||
device_p->device_type = DeviceType::BOILER;
|
device_p->device_type = DeviceType::BOILER;
|
||||||
}
|
}
|
||||||
break;
|
break;
|
||||||
|
} else if (device.device_type == DeviceType::HEATPUMP) { // integrated modules, same product_id
|
||||||
|
device_p = &device;
|
||||||
|
if (device_id == 0x48) {
|
||||||
|
device_p->device_type = DeviceType::GATEWAY;
|
||||||
|
device_p->name = "WiFi module";
|
||||||
|
} else if (device_id == 0x50) {
|
||||||
|
device_p->device_type = DeviceType::CONNECT;
|
||||||
|
device_p->name = "Wireless sensor base";
|
||||||
|
}
|
||||||
|
break;
|
||||||
} else {
|
} else {
|
||||||
// it's not a boiler, but we have a match
|
// it's not a boiler, but we have a match
|
||||||
device_p = &device;
|
device_p = &device;
|
||||||
|
|||||||
Reference in New Issue