mirror of
https://github.com/emsesp/EMS-ESP32.git
synced 2025-12-07 00:09:51 +03:00
v3.7.1
This commit is contained in:
87
CHANGELOG.md
87
CHANGELOG.md
@@ -5,6 +5,93 @@ All notable changes to this project will be documented in this file.
|
|||||||
The format is based on [Keep a Changelog](https://keepachangelog.com/en/1.0.0/),
|
The format is based on [Keep a Changelog](https://keepachangelog.com/en/1.0.0/),
|
||||||
and this project adheres to [Semantic Versioning](https://semver.org/spec/v2.0.0.html).
|
and this project adheres to [Semantic Versioning](https://semver.org/spec/v2.0.0.html).
|
||||||
|
|
||||||
|
## [3.7.0] 27 October 2024
|
||||||
|
|
||||||
|
## **IMPORTANT! BREAKING CHANGES with 3.6.5**
|
||||||
|
|
||||||
|
- "ww" and "wwc" has been renamed to "dhw". It is nested JSON object in both the MQTT and API outputs. The old prefix has also been removed from MQTT topics ([#1634](https://github.com/emsesp/EMS-ESP32/issues/1634)). This will impact historical data in home automation systems like Home Assistant and IOBroker. To preserve the current value of dhw energy (was previously nrgww) refer to this issue [#1938](https://github.com/emsesp/EMS-ESP32/issues/1938).
|
||||||
|
- dhw entities from the MM100/SM100 have been moved under a new Device called 'water'.
|
||||||
|
- The automatically generated temperature sensor ID has replaced dashes (`-`) with underscores (`_`) to be compatible with Home Assistant.
|
||||||
|
- `api/system/info` has it's JSON key names changed to camelCase syntax.
|
||||||
|
|
||||||
|
For more details go to [www.emsesp.org](https://www.emsesp.org/).
|
||||||
|
|
||||||
|
## Added
|
||||||
|
|
||||||
|
- some more entities for dhw with SM100 module
|
||||||
|
- thermostat second dhw circuit [#1634](https://github.com/emsesp/EMS-ESP32/issues/1634)
|
||||||
|
- remote thermostat emulation for RC100H, RC200 and FB10 [#1287](https://github.com/emsesp/EMS-ESP32/discussions/1287), [#1602](https://github.com/emsesp/EMS-ESP32/discussions/1602), [#1551](https://github.com/emsesp/EMS-ESP32/discussions/1551)
|
||||||
|
- heatpump dhw stop temperatures [#1624](https://github.com/emsesp/EMS-ESP32/issues/1624)
|
||||||
|
- reset history [#1695](https://github.com/emsesp/EMS-ESP32/issues/1695)
|
||||||
|
- heatpump entities `fan` and `shutdown` [#1690](https://github.com/emsesp/EMS-ESP32/discussions/1690)
|
||||||
|
- mqtt HA-mode 3 for v3.6 compatible HA entities, set on update v3.6->v3.7
|
||||||
|
- HP input states [#1723](https://github.com/emsesp/EMS-ESP32/discussions/1723)
|
||||||
|
- holiday settings for rego 3000 [#1735](https://github.com/emsesp/EMS-ESP32/issues/1735)
|
||||||
|
- Added scripts for OTA (scripts/upload.py and upload_cli.py) [#1738](https://github.com/emsesp/EMS-ESP32/issues/1738)
|
||||||
|
- timeout for remote thermostat emulation [#1680](https://github.com/emsesp/EMS-ESP32/discussions/1680), [#1774](https://github.com/emsesp/EMS-ESP32/issues/1774)
|
||||||
|
- CR120 thermostat as own model() [#1779](https://github.com/emsesp/EMS-ESP32/discussions/1779)
|
||||||
|
- modules - external linkable module library [#1778](https://github.com/emsesp/EMS-ESP32/issues/1778)
|
||||||
|
- scheduler onChange and Conditions [#1806](https://github.com/emsesp/EMS-ESP32/issues/1806)
|
||||||
|
- make remote control timeout editable [#1774](https://github.com/emsesp/EMS-ESP32/issues/1774)
|
||||||
|
- added extra pump characteristics (mode and pressure for EMS+) by @SLTKA [#1802](https://github.com/emsesp/EMS-ESP32/pull/1802)
|
||||||
|
- allow device name to be customized [#1174](https://github.com/emsesp/EMS-ESP32/issues/1174)
|
||||||
|
- Modbus support by @mheyse [#1744](https://github.com/emsesp/EMS-ESP32/issues/1744)
|
||||||
|
- System Message command [#1854](https://github.com/emsesp/EMS-ESP32/issues/1854)
|
||||||
|
- scheduler can use web get/post for values and commands [#1806](https://github.com/emsesp/EMS-ESP32/issues/1806)
|
||||||
|
- RT800 remote emulation [#1867](https://github.com/emsesp/EMS-ESP32/issues/1867)
|
||||||
|
- RC310 cooling parameters [#1857](https://github.com/emsesp/EMS-ESP32/issues/1857)
|
||||||
|
- command `api/device/entities` [#1897](https://github.com/emsesp/EMS-ESP32/issues/1897)
|
||||||
|
- switchprogmode [#1903](https://github.com/emsesp/EMS-ESP32/discussions/1903)
|
||||||
|
- autodetect and download firmware upgrades via the WebUI
|
||||||
|
- command 'show log' that lists out the current weblog buffer, showing last messages.
|
||||||
|
- default web log buffer to 25 lines for ESP32s with no PSRAM
|
||||||
|
- try and determine correct board profile if none is set during boot
|
||||||
|
- auto Scroll in WebLog UI - reduced delay so incoming logs are faster
|
||||||
|
- uploading custom support info, shown to Guest users in Help page [#2054](https://github.com/emsesp/EMS-ESP32/issues/2054)
|
||||||
|
- feature: Dashboard showing all data (favorites, sensors, custom) [#1958](https://github.com/emsesp/EMS-ESP32/issues/1958)
|
||||||
|
- entity for low-temperature boilers pump start temp (pumpOnTemp) #2088 [#2088](https://github.com/emsesp/EMS-ESP32/issues/2088)
|
||||||
|
- internal ESP32 temperature sensor on the S3 [#2077](https://github.com/emsesp/EMS-ESP32/issues/2077)
|
||||||
|
- MQTT status topic (used in connect and last will) set to Retain [#2086](https://github.com/emsesp/EMS-ESP32/discussions/2086)
|
||||||
|
- Czech language [2096](https://github.com/emsesp/EMS-ESP32/issues/2096)
|
||||||
|
- Developer Mode and send EMS Read Commands from WebUI [#2116](https://github.com/emsesp/EMS-ESP32/issues/2116)
|
||||||
|
- Scheduler functions [#2115](https://github.com/emsesp/EMS-ESP32/issues/2115)
|
||||||
|
- Set device custom name from telegram 0x01 [#2073](https://github.com/emsesp/EMS-ESP32/issues/2073)
|
||||||
|
|
||||||
|
## Fixed
|
||||||
|
|
||||||
|
- remote thermostat emulation for RC200 on Rego2000/3000 thermostats [#1691](https://github.com/emsesp/EMS-ESP32/discussions/1691)
|
||||||
|
- log shows data for F7/F9 requests
|
||||||
|
- Detection of LittleFS for factory setting wasn't working
|
||||||
|
- Check for bad GPIOs with Ethernet before the ethernet is initialized
|
||||||
|
- Show values with factor 50 on webUI [#2064](https://github.com/emsesp/EMS-ESP32/issues/2064)
|
||||||
|
- Rendering of values between -1 and 0
|
||||||
|
- Value for 32bit times not-set [#2109](https://github.com/emsesp/EMS-ESP32/issues/2109)
|
||||||
|
|
||||||
|
## Changed
|
||||||
|
|
||||||
|
- use flag for BC400 compatible thermostats, manage different mode settings
|
||||||
|
- use factory partition for 16M flash
|
||||||
|
- store digital out states to nvs
|
||||||
|
- Refresh UI - moving settings to one location [#1665](https://github.com/emsesp/EMS-ESP32/issues/1665)
|
||||||
|
- rename DeviceValueTypes, add UINT32 for custom entities
|
||||||
|
- dynamic register dhw circuits for thermostat
|
||||||
|
- removed OTA feature [#1738](https://github.com/emsesp/EMS-ESP32/issues/1738)
|
||||||
|
- added shower min duration [#1801](https://github.com/emsesp/EMS-ESP32/issues/1801)
|
||||||
|
- Include TXT file along with the generated CSV for Device Data export/download
|
||||||
|
- thermostat/remotetemp as command [#1835](https://github.com/emsesp/EMS-ESP32/discussions/1835)
|
||||||
|
- temperaturesensor id notation with underscore [#1794](https://github.com/emsesp/EMS-ESP32/discussions/1794)
|
||||||
|
- Change key-names in JSON to be compliant and consistent [#1860](https://github.com/emsesp/EMS-ESP32/issues/1860)
|
||||||
|
- Updates to webUI [#1920](https://github.com/emsesp/EMS-ESP32/issues/1920)
|
||||||
|
- Correct firmware naming #1933 [#1933](https://github.com/emsesp/EMS-ESP32/issues/1933)
|
||||||
|
- Don't start Serial console if not connected to a Serial port. Will initiate manually after a CTRL-C/CTRL-S
|
||||||
|
- WebLog UI matches color schema of the terminal console correctly
|
||||||
|
- Updated Web libraries, ArduinoJson
|
||||||
|
- Help page doesn't show detailed tech info if the user is not 'admin' role [#2054](https://github.com/emsesp/EMS-ESP32/issues/2054)
|
||||||
|
- removed system command `allvalues` and moved to an action called `export`
|
||||||
|
- Show ems-esp internal devices in device list of system/info
|
||||||
|
- Scheduler and mqtt run async on systems with psram
|
||||||
|
- Show IPv6 address type (local/global/ula) in log
|
||||||
|
|
||||||
## [3.6.5] March 23 2024
|
## [3.6.5] March 23 2024
|
||||||
|
|
||||||
## **IMPORTANT! BREAKING CHANGES**
|
## **IMPORTANT! BREAKING CHANGES**
|
||||||
|
|||||||
@@ -1,88 +1,13 @@
|
|||||||
# Changelog
|
# Changelog
|
||||||
|
|
||||||
## [3.7.0]
|
## [3.7.1]
|
||||||
|
|
||||||
## **IMPORTANT! BREAKING CHANGES with 3.6.5**
|
## **IMPORTANT! BREAKING CHANGES with 3.7.0**
|
||||||
|
|
||||||
- "ww" and "wwc" has been renamed to "dhw". It is nested JSON object in both the MQTT and API outputs. The old prefix has also been removed from MQTT topics ([#1634](https://github.com/emsesp/EMS-ESP32/issues/1634)). This will impact historical data in home automation systems like Home Assistant and IOBroker. To preserve the current value of dhw energy (was previously nrgww) refer to this issue [#1938](https://github.com/emsesp/EMS-ESP32/issues/1938).
|
|
||||||
- dhw entities from the MM100/SM100 have been moved under a new Device called 'water'.
|
|
||||||
- The automatically generated temperature sensor ID has replaced dashes (`-`) with underscores (`_`) to be compatible with Home Assistant.
|
|
||||||
- `api/system/info` has it's JSON key names changed to camelCase syntax.
|
|
||||||
|
|
||||||
For more details go to [www.emsesp.org](https://www.emsesp.org/).
|
For more details go to [www.emsesp.org](https://www.emsesp.org/).
|
||||||
|
|
||||||
## Added
|
## Added
|
||||||
|
|
||||||
- some more entities for dhw with SM100 module
|
|
||||||
- thermostat second dhw circuit [#1634](https://github.com/emsesp/EMS-ESP32/issues/1634)
|
|
||||||
- remote thermostat emulation for RC100H, RC200 and FB10 [#1287](https://github.com/emsesp/EMS-ESP32/discussions/1287), [#1602](https://github.com/emsesp/EMS-ESP32/discussions/1602), [#1551](https://github.com/emsesp/EMS-ESP32/discussions/1551)
|
|
||||||
- heatpump dhw stop temperatures [#1624](https://github.com/emsesp/EMS-ESP32/issues/1624)
|
|
||||||
- reset history [#1695](https://github.com/emsesp/EMS-ESP32/issues/1695)
|
|
||||||
- heatpump entities `fan` and `shutdown` [#1690](https://github.com/emsesp/EMS-ESP32/discussions/1690)
|
|
||||||
- mqtt HA-mode 3 for v3.6 compatible HA entities, set on update v3.6->v3.7
|
|
||||||
- HP input states [#1723](https://github.com/emsesp/EMS-ESP32/discussions/1723)
|
|
||||||
- holiday settings for rego 3000 [#1735](https://github.com/emsesp/EMS-ESP32/issues/1735)
|
|
||||||
- Added scripts for OTA (scripts/upload.py and upload_cli.py) [#1738](https://github.com/emsesp/EMS-ESP32/issues/1738)
|
|
||||||
- timeout for remote thermostat emulation [#1680](https://github.com/emsesp/EMS-ESP32/discussions/1680), [#1774](https://github.com/emsesp/EMS-ESP32/issues/1774)
|
|
||||||
- CR120 thermostat as own model() [#1779](https://github.com/emsesp/EMS-ESP32/discussions/1779)
|
|
||||||
- modules - external linkable module library [#1778](https://github.com/emsesp/EMS-ESP32/issues/1778)
|
|
||||||
- scheduler onChange and Conditions [#1806](https://github.com/emsesp/EMS-ESP32/issues/1806)
|
|
||||||
- make remote control timeout editable [#1774](https://github.com/emsesp/EMS-ESP32/issues/1774)
|
|
||||||
- added extra pump characteristics (mode and pressure for EMS+) by @SLTKA [#1802](https://github.com/emsesp/EMS-ESP32/pull/1802)
|
|
||||||
- allow device name to be customized [#1174](https://github.com/emsesp/EMS-ESP32/issues/1174)
|
|
||||||
- Modbus support by @mheyse [#1744](https://github.com/emsesp/EMS-ESP32/issues/1744)
|
|
||||||
- System Message command [#1854](https://github.com/emsesp/EMS-ESP32/issues/1854)
|
|
||||||
- scheduler can use web get/post for values and commands [#1806](https://github.com/emsesp/EMS-ESP32/issues/1806)
|
|
||||||
- RT800 remote emulation [#1867](https://github.com/emsesp/EMS-ESP32/issues/1867)
|
|
||||||
- RC310 cooling parameters [#1857](https://github.com/emsesp/EMS-ESP32/issues/1857)
|
|
||||||
- command `api/device/entities` [#1897](https://github.com/emsesp/EMS-ESP32/issues/1897)
|
|
||||||
- switchprogmode [#1903](https://github.com/emsesp/EMS-ESP32/discussions/1903)
|
|
||||||
- autodetect and download firmware upgrades via the WebUI
|
|
||||||
- command 'show log' that lists out the current weblog buffer, showing last messages.
|
|
||||||
- default web log buffer to 25 lines for ESP32s with no PSRAM
|
|
||||||
- try and determine correct board profile if none is set during boot
|
|
||||||
- auto Scroll in WebLog UI - reduced delay so incoming logs are faster
|
|
||||||
- uploading custom support info, shown to Guest users in Help page [#2054](https://github.com/emsesp/EMS-ESP32/issues/2054)
|
|
||||||
- feature: Dashboard showing all data (favorites, sensors, custom) [#1958](https://github.com/emsesp/EMS-ESP32/issues/1958)
|
|
||||||
- entity for low-temperature boilers pump start temp (pumpOnTemp) #2088 [#2088](https://github.com/emsesp/EMS-ESP32/issues/2088)
|
|
||||||
- internal ESP32 temperature sensor on the S3 [#2077](https://github.com/emsesp/EMS-ESP32/issues/2077)
|
|
||||||
- MQTT status topic (used in connect and last will) set to Retain [#2086](https://github.com/emsesp/EMS-ESP32/discussions/2086)
|
|
||||||
- Czech language [2096](https://github.com/emsesp/EMS-ESP32/issues/2096)
|
|
||||||
- Developer Mode and send EMS Read Commands from WebUI [#2116](https://github.com/emsesp/EMS-ESP32/issues/2116)
|
|
||||||
- Scheduler functions [#2115](https://github.com/emsesp/EMS-ESP32/issues/2115)
|
|
||||||
- Set device custom name from telegram 0x01 [#2073](https://github.com/emsesp/EMS-ESP32/issues/2073)
|
|
||||||
|
|
||||||
## Fixed
|
## Fixed
|
||||||
|
|
||||||
- remote thermostat emulation for RC200 on Rego2000/3000 thermostats [#1691](https://github.com/emsesp/EMS-ESP32/discussions/1691)
|
|
||||||
- log shows data for F7/F9 requests
|
|
||||||
- Detection of LittleFS for factory setting wasn't working
|
|
||||||
- Check for bad GPIOs with Ethernet before the ethernet is initialized
|
|
||||||
- Show values with factor 50 on webUI [#2064](https://github.com/emsesp/EMS-ESP32/issues/2064)
|
|
||||||
- Rendering of values between -1 and 0
|
|
||||||
- Value for 32bit times not-set [#2109](https://github.com/emsesp/EMS-ESP32/issues/2109)
|
|
||||||
|
|
||||||
## Changed
|
## Changed
|
||||||
|
|
||||||
- use flag for BC400 compatible thermostats, manage different mode settings
|
|
||||||
- use factory partition for 16M flash
|
|
||||||
- store digital out states to nvs
|
|
||||||
- Refresh UI - moving settings to one location [#1665](https://github.com/emsesp/EMS-ESP32/issues/1665)
|
|
||||||
- rename DeviceValueTypes, add UINT32 for custom entities
|
|
||||||
- dynamic register dhw circuits for thermostat
|
|
||||||
- removed OTA feature [#1738](https://github.com/emsesp/EMS-ESP32/issues/1738)
|
|
||||||
- added shower min duration [#1801](https://github.com/emsesp/EMS-ESP32/issues/1801)
|
|
||||||
- Include TXT file along with the generated CSV for Device Data export/download
|
|
||||||
- thermostat/remotetemp as command [#1835](https://github.com/emsesp/EMS-ESP32/discussions/1835)
|
|
||||||
- temperaturesensor id notation with underscore [#1794](https://github.com/emsesp/EMS-ESP32/discussions/1794)
|
|
||||||
- Change key-names in JSON to be compliant and consistent [#1860](https://github.com/emsesp/EMS-ESP32/issues/1860)
|
|
||||||
- Updates to webUI [#1920](https://github.com/emsesp/EMS-ESP32/issues/1920)
|
|
||||||
- Correct firmware naming #1933 [#1933](https://github.com/emsesp/EMS-ESP32/issues/1933)
|
|
||||||
- Don't start Serial console if not connected to a Serial port. Will initiate manually after a CTRL-C/CTRL-S
|
|
||||||
- WebLog UI matches color schema of the terminal console correctly
|
|
||||||
- Updated Web libraries, ArduinoJson
|
|
||||||
- Help page doesn't show detailed tech info if the user is not 'admin' role [#2054](https://github.com/emsesp/EMS-ESP32/issues/2054)
|
|
||||||
- removed system command `allvalues` and moved to an action called `export`
|
|
||||||
- Show ems-esp internal devices in device list of system/info
|
|
||||||
- Scheduler and mqtt run async on systems with psram
|
|
||||||
- Show IPv6 address type (local/global/ula) in log
|
|
||||||
|
|||||||
@@ -1 +1 @@
|
|||||||
#define EMSESP_APP_VERSION "3.7.0-dev.49"
|
#define EMSESP_APP_VERSION "3.7.1-dev.0"
|
||||||