version 1.3.0

This commit is contained in:
proddy
2019-01-09 23:41:41 +01:00
parent 2d2ee1927d
commit 22823545da
28 changed files with 1730 additions and 758 deletions

View File

@@ -1,16 +1,37 @@
# EMS-ESP-Boiler Changelog
# EMS-ESP Changelog
All notable changes to this project will be documented in this file.
The format is based on [Keep a Changelog](https://keepachangelog.com/en/1.0.0/),
and this project adheres to [Semantic Versioning](https://semver.org/spec/v2.0.0.html).
## [1.3.0] 2019-01-09
### Changed
- Renamed project from EMS-ESP-Boiler to EMS-ESP since it's kinda EMS generic now
- Support for RC20F and RFM20 (https://github.com/proddy/EMS-ESP/issues/18)
- Moved all EMS device information into a separate file `ems_devices.h` so no longer need to touch `ems.h`
- Telnet commands can be strings now and output is suspended when typing
### Removed
- Removed SHOWER_TEST
- Removed WIFI and MQTT credentials from the platformio.ini file
### Added
- Settings are saved and loaded from the ESP8266's file system (SPIFFS). Can be set using the 'set' command
- Improved support when in Access Point mode (192.168.4.1)
- pre-built firmwares are back
## [1.2.4] 2019-01-04
### Changed
- Scanning known EMS Devices now ignores duplicates (https://github.com/proddy/EMS-ESP-Boiler/pull/30)
- Scanning known EMS Devices now ignores duplicates (https://github.com/proddy/EMS-ESP/pull/30)
- ServiceCode stored as a two byte char
- Support for RC20F and RFM20 (https://github.com/proddy/EMS-ESP/issues/18)
## [1.2.3] 2019-01-03
@@ -18,23 +39,23 @@ and this project adheres to [Semantic Versioning](https://semver.org/spec/v2.0.0
- Can now hardcode Boiler and Thermostat types in my_config.h to bypass auto-detection
- Fixed MQTT subscribing to Heating and Hot Water active topics
- Fixed for listening to incoming MQTT topics (https://github.com/proddy/EMS-ESP-Boiler/issues/27)
- Fixed handling of current temperature on an RC35-type thermostat that doesn't have a sensor (https://github.com/proddy/EMS-ESP-Boiler/issues/18)
- Fixed for listening to incoming MQTT topics (https://github.com/proddy/EMS-ESP/issues/27)
- Fixed handling of current temperature on an RC35-type thermostat that doesn't have a sensor (https://github.com/proddy/EMS-ESP/issues/18)
## [1.2.2] 2019-01-02
### Fixed
- Issues in 1.2.1 (see https://github.com/proddy/EMS-ESP-Boiler/issues/25)
- Issues in 1.2.1 (see https://github.com/proddy/EMS-ESP/issues/25)
- Logic for determining if there is activity on the EMS bus and using the onboard LEDs properly
## [1.2.1] 2019-01-02
### Fixed
- Only process broadcast messages if the offset (byte 4) is 0. (https://github.com/proddy/EMS-ESP-Boiler/issues/23)
- Only process broadcast messages if the offset (byte 4) is 0. (https://github.com/proddy/EMS-ESP/issues/23)
- Improved checking for duplicate sent Tx telegrams by comparing CRCs
- Removed distiquishing between noise on the line and corrupt telegrams (https://github.com/proddy/EMS-ESP-Boiler/issues/24)
- Removed distiquishing between noise on the line and corrupt telegrams (https://github.com/proddy/EMS-ESP/issues/24)
## [1.2.0] 2019-01-01
@@ -54,7 +75,7 @@ and this project adheres to [Semantic Versioning](https://semver.org/spec/v2.0.0
- Fetch UBATotalUptimeMessage from Boiler to get total working minutes
- Added check to see if bus is connected. Shown in stats page
- If no Wifi connection can be made, start up as a WiFi Access Point (AP)
- Report out service codes and water-flow [pull-request](https://github.com/proddy/EMS-ESP-Boiler/pull/20/files). Thanks @Bonusbartus
- Report out service codes and water-flow [pull-request](https://github.com/proddy/EMS-ESP/pull/20/files). Thanks @Bonusbartus
### Changed
@@ -83,16 +104,16 @@ and this project adheres to [Semantic Versioning](https://semver.org/spec/v2.0.0
- Fixed handling of negative floating point values (like outdoor temp)
- Fixed handling of auto & manual mode on an RC30
- [Fixed condition where all telegram types were processed, instead of only broadcasts or our own reads](https://github.com/proddy/EMS-ESP-Boiler/issues/15)
- [Fixed condition where all telegram types were processed, instead of only broadcasts or our own reads](https://github.com/proddy/EMS-ESP/issues/15)
### Added
- Created this CHANGELOG.md file!
- [Added support for the Nefit Easy thermostat, reading of temperature values only](https://github.com/proddy/EMS-ESP-Boiler/issues/9) - note *read only* (big thanks @**kroon040** for lending me an Easy device)
- [Added support for RC35/Moduline 400](https://github.com/proddy/EMS-ESP-Boiler/issues/14) - *read only*
- [New raw logging mode for logging](https://github.com/proddy/EMS-ESP-Boiler/issues/11)
- [New 'r'command to send raw data to EMS](https://github.com/proddy/EMS-ESP-Boiler/issues/11)
- [Added MQTT messages for hot water on and heating on](https://github.com/proddy/EMS-ESP-Boiler/issues/10)
- [Added support for the Nefit Easy thermostat, reading of temperature values only](https://github.com/proddy/EMS-ESP/issues/9) - note *read only* (big thanks @**kroon040** for lending me an Easy device)
- [Added support for RC35/Moduline 400](https://github.com/proddy/EMS-ESP/issues/14) - *read only*
- [New raw logging mode for logging](https://github.com/proddy/EMS-ESP/issues/11)
- [New 'r'command to send raw data to EMS](https://github.com/proddy/EMS-ESP/issues/11)
- [Added MQTT messages for hot water on and heating on](https://github.com/proddy/EMS-ESP/issues/10)
- Implemented FIFO circular buffer queue for up to 20 Tx messages (Q command to show queue)
- Toggle Tx transmission via telnet (use 'X' command)
- Show thermostat type in help stats (use 's' command)