mirror of
https://github.com/emsesp/EMS-ESP32.git
synced 2025-12-07 16:29:51 +03:00
add wwMaxPower and wwFlowTempOffset
This commit is contained in:
@@ -58,6 +58,7 @@ Boiler::Boiler(uint8_t device_type, int8_t device_id, uint8_t product_id, const
|
||||
register_telegram_type(0x19, F("UBAMonitorSlow"), true, [&](std::shared_ptr<const Telegram> t) { process_UBAMonitorSlow(t); });
|
||||
register_telegram_type(0x1A, F("UBASetPoints"), false, [&](std::shared_ptr<const Telegram> t) { process_UBASetPoints(t); });
|
||||
register_telegram_type(0x1C, F("UBAMaintenanceStatus"), false, [&](std::shared_ptr<const Telegram> t) { process_UBAMaintenanceStatus(t); });
|
||||
register_telegram_type(0x26, F("UBASettingsWW"), true, [&](std::shared_ptr<const Telegram> t) { process_UBASettingsWW(t); });
|
||||
register_telegram_type(0x2A, F("MC10Status"), false, [&](std::shared_ptr<const Telegram> t) { process_MC10Status(t); });
|
||||
register_telegram_type(0x33, F("UBAParameterWW"), true, [&](std::shared_ptr<const Telegram> t) { process_UBAParameterWW(t); });
|
||||
register_telegram_type(0x34, F("UBAMonitorWW"), false, [&](std::shared_ptr<const Telegram> t) { process_UBAMonitorWW(t); });
|
||||
@@ -82,6 +83,7 @@ Boiler::Boiler(uint8_t device_type, int8_t device_id, uint8_t product_id, const
|
||||
register_mqtt_cmd(F("wwactivated"), [&](const char * value, const int8_t id) { return set_warmwater_activated(value, id); });
|
||||
register_mqtt_cmd(F("wwtapactivated"), [&](const char * value, const int8_t id) { return set_tapwarmwater_activated(value, id); });
|
||||
register_mqtt_cmd(F("wwflowtempoffset"), [&](const char * value, const int8_t id) { return set_wWFlowTempOffset(value, id); });
|
||||
register_mqtt_cmd(F("wwmaxpower"), [&](const char * value, const int8_t id) { return set_warmwater_maxpower(value, id); });
|
||||
register_mqtt_cmd(F("wwonetime"), [&](const char * value, const int8_t id) { return set_warmwater_onetime(value, id); });
|
||||
register_mqtt_cmd(F("wwcircpump"), [&](const char * value, const int8_t id) { return set_warmwater_circulation_pump(value, id); });
|
||||
register_mqtt_cmd(F("wwcirculation"), [&](const char * value, const int8_t id) { return set_warmwater_circulation(value, id); });
|
||||
@@ -176,6 +178,8 @@ Boiler::Boiler(uint8_t device_type, int8_t device_id, uint8_t product_id, const
|
||||
register_device_value(TAG_BOILER_DATA_WW, &wWSetTemp_, DeviceValueType::UINT, nullptr, F("wWSetTemp"), F("set temperature"), DeviceValueUOM::DEGREES);
|
||||
register_device_value(TAG_BOILER_DATA_WW, &wWType_, DeviceValueType::ENUM, FL_(enum_flow), F("wWType"), F("type"));
|
||||
register_device_value(TAG_BOILER_DATA_WW, &wWComfort_, DeviceValueType::ENUM, FL_(enum_comfort), F("wWComfort"), F("comfort"));
|
||||
register_device_value(TAG_BOILER_DATA_WW, &wWFlowTempOffset_, DeviceValueType::UINT, nullptr, F("wWFlowTempOffset"), F("flow offset temperature"));
|
||||
register_device_value(TAG_BOILER_DATA_WW, &wWMaxPower_, DeviceValueType::UINT, nullptr, F("wWMaxPower"), F("max power"), DeviceValueUOM::PERCENT);
|
||||
register_device_value(TAG_BOILER_DATA_WW, &wWCircPump_, DeviceValueType::BOOL, nullptr, F("wWCircPump"), F("circulation pump available"));
|
||||
register_device_value(TAG_BOILER_DATA_WW, &wWChargeType_, DeviceValueType::BOOL, FL_(enum_charge), F("wWChargeType"), F("charging type"));
|
||||
register_device_value(TAG_BOILER_DATA_WW, &wWDisinfectionTemp_, DeviceValueType::UINT, nullptr, F("wWDisinfectionTemp"), F("disinfection temperature"), DeviceValueUOM::DEGREES);
|
||||
@@ -356,6 +360,14 @@ void Boiler::process_UBAParameters(std::shared_ptr<const Telegram> telegram) {
|
||||
has_update(telegram->read_value(pumpModMin_, 10));
|
||||
}
|
||||
|
||||
/*
|
||||
* UBASettingsWW - type 0x26 - max power on offset 7, #740
|
||||
* Boiler(0x08) -> Me(0x0B), ?(0x26), data: 01 05 00 0F 00 1E 58 5A
|
||||
*/
|
||||
void Boiler::process_UBASettingsWW(std::shared_ptr<const Telegram> telegram) {
|
||||
has_update(telegram->read_value(wWMaxPower_, 7));
|
||||
}
|
||||
|
||||
/*
|
||||
* UBAMonitorWW - type 0x34 - warm water monitor. 19 bytes long
|
||||
* received every 10 seconds
|
||||
@@ -795,6 +807,20 @@ bool Boiler::set_max_power(const char * value, const int8_t id) {
|
||||
return true;
|
||||
}
|
||||
|
||||
// set warm water max power
|
||||
bool Boiler::set_warmwater_maxpower(const char * value, const int8_t id) {
|
||||
int v = 0;
|
||||
if (!Helpers::value2number(value, v)) {
|
||||
LOG_WARNING(F("Set warm water max power: Invalid value"));
|
||||
return false;
|
||||
}
|
||||
|
||||
LOG_INFO(F("Setting warm water max power to %d %%"), v);
|
||||
write_command(EMS_TYPE_UBASettingsWW, 7, v, EMS_TYPE_UBASettingsWW);
|
||||
|
||||
return true;
|
||||
}
|
||||
|
||||
// set min pump modulation
|
||||
bool Boiler::set_min_pump(const char * value, const int8_t id) {
|
||||
int v = 0;
|
||||
|
||||
Reference in New Issue
Block a user