@@ -48,6 +48,14 @@
|
||||
#define EMS_THERMOSTAT_DEFAULTHC 1 // default heating circuit is 1
|
||||
#define EMS_THERMOSTAT_WRITE_YES true
|
||||
#define EMS_THERMOSTAT_WRITE_NO false
|
||||
typedef enum {
|
||||
EMS_THERMOSTAT_MODE_UNKNOWN,
|
||||
EMS_THERMOSTAT_MODE_OFF,
|
||||
EMS_THERMOSTAT_MODE_MANUAL,
|
||||
EMS_THERMOSTAT_MODE_AUTO,
|
||||
EMS_THERMOSTAT_MODE_NIGHT,
|
||||
EMS_THERMOSTAT_MODE_DAY
|
||||
} _EMS_THERMOSTAT_MODE;
|
||||
|
||||
// trigger settings to determine if hot tap water or the heating is active
|
||||
#define EMS_BOILER_BURNPOWER_TAPWATER 100
|
||||
|
||||