@@ -160,8 +160,8 @@ device name,device type,product id,shortname,fullname,type [options...] \| (min/
|
||||
"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,comfoff,comfort switch off,uint8 (>=15<=65),C,true,number.boiler_dhw_comfort_switch_off,number.boiler_dhw_comfoff,5,9,1,-1,1
|
||||
"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,ecooff,eco switch off,uint8 (>=15<=65),C,true,number.boiler_dhw_eco_switch_off,number.boiler_dhw_ecooff,5,9,1,-1,1
|
||||
"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,ecoplusoff,eco+ switch off,uint8 (>=48<=63),C,true,number.boiler_dhw_eco+_switch_off,number.boiler_dhw_ecoplusoff,5,9,1,-1,1
|
||||
"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,comfdiff,comfort diff,uint8 (>=6<=12),K,true,number.boiler_dhw_comfort_diff,number.boiler_dhw_comfdiff,5,9,1,-1,1
|
||||
"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,ecodiff,eco diff,uint8 (>=6<=12),K,true,number.boiler_dhw_eco_diff,number.boiler_dhw_ecodiff,5,9,1,-1,1
|
||||
"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,comfdiff,comfort diff,uint8 (>=4<=12),K,true,number.boiler_dhw_comfort_diff,number.boiler_dhw_comfdiff,5,9,1,-1,1
|
||||
"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,ecodiff,eco diff,uint8 (>=4<=12),K,true,number.boiler_dhw_eco_diff,number.boiler_dhw_ecodiff,5,9,1,-1,1
|
||||
"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,ecoplusdiff,eco+ diff,uint8 (>=6<=12),K,true,number.boiler_dhw_eco+_diff,number.boiler_dhw_ecoplusdiff,5,9,1,-1,1
|
||||
"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,comfstop,comfort stop temp,uint8 (>=0<=254),C,true,number.boiler_dhw_comfort_stop_temp,number.boiler_dhw_comfstop,5,9,1,-1,1
|
||||
"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,ecostop,eco stop temp,uint8 (>=0<=254),C,true,number.boiler_dhw_eco_stop_temp,number.boiler_dhw_ecostop,5,9,1,-1,1
|
||||
@@ -2668,8 +2668,8 @@ device name,device type,product id,shortname,fullname,type [options...] \| (min/
|
||||
"Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i",boiler,172,comfoff,comfort switch off,uint8 (>=15<=65),C,true,number.boiler_dhw_comfort_switch_off,number.boiler_dhw_comfoff,5,9,1,-1,1
|
||||
"Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i",boiler,172,ecooff,eco switch off,uint8 (>=15<=65),C,true,number.boiler_dhw_eco_switch_off,number.boiler_dhw_ecooff,5,9,1,-1,1
|
||||
"Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i",boiler,172,ecoplusoff,eco+ switch off,uint8 (>=48<=63),C,true,number.boiler_dhw_eco+_switch_off,number.boiler_dhw_ecoplusoff,5,9,1,-1,1
|
||||
"Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i",boiler,172,comfdiff,comfort diff,uint8 (>=6<=12),K,true,number.boiler_dhw_comfort_diff,number.boiler_dhw_comfdiff,5,9,1,-1,1
|
||||
"Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i",boiler,172,ecodiff,eco diff,uint8 (>=6<=12),K,true,number.boiler_dhw_eco_diff,number.boiler_dhw_ecodiff,5,9,1,-1,1
|
||||
"Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i",boiler,172,comfdiff,comfort diff,uint8 (>=4<=12),K,true,number.boiler_dhw_comfort_diff,number.boiler_dhw_comfdiff,5,9,1,-1,1
|
||||
"Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i",boiler,172,ecodiff,eco diff,uint8 (>=4<=12),K,true,number.boiler_dhw_eco_diff,number.boiler_dhw_ecodiff,5,9,1,-1,1
|
||||
"Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i",boiler,172,ecoplusdiff,eco+ diff,uint8 (>=6<=12),K,true,number.boiler_dhw_eco+_diff,number.boiler_dhw_ecoplusdiff,5,9,1,-1,1
|
||||
"Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i",boiler,172,comfstop,comfort stop temp,uint8 (>=0<=254),C,true,number.boiler_dhw_comfort_stop_temp,number.boiler_dhw_comfstop,5,9,1,-1,1
|
||||
"Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i",boiler,172,ecostop,eco stop temp,uint8 (>=0<=254),C,true,number.boiler_dhw_eco_stop_temp,number.boiler_dhw_ecostop,5,9,1,-1,1
|
||||
@@ -2876,8 +2876,8 @@ device name,device type,product id,shortname,fullname,type [options...] \| (min/
|
||||
"Geo 5xx",boiler,173,comfoff,comfort switch off,uint8 (>=15<=65),C,true,number.boiler_dhw_comfort_switch_off,number.boiler_dhw_comfoff,5,9,1,-1,1
|
||||
"Geo 5xx",boiler,173,ecooff,eco switch off,uint8 (>=15<=65),C,true,number.boiler_dhw_eco_switch_off,number.boiler_dhw_ecooff,5,9,1,-1,1
|
||||
"Geo 5xx",boiler,173,ecoplusoff,eco+ switch off,uint8 (>=48<=63),C,true,number.boiler_dhw_eco+_switch_off,number.boiler_dhw_ecoplusoff,5,9,1,-1,1
|
||||
"Geo 5xx",boiler,173,comfdiff,comfort diff,uint8 (>=6<=12),K,true,number.boiler_dhw_comfort_diff,number.boiler_dhw_comfdiff,5,9,1,-1,1
|
||||
"Geo 5xx",boiler,173,ecodiff,eco diff,uint8 (>=6<=12),K,true,number.boiler_dhw_eco_diff,number.boiler_dhw_ecodiff,5,9,1,-1,1
|
||||
"Geo 5xx",boiler,173,comfdiff,comfort diff,uint8 (>=4<=12),K,true,number.boiler_dhw_comfort_diff,number.boiler_dhw_comfdiff,5,9,1,-1,1
|
||||
"Geo 5xx",boiler,173,ecodiff,eco diff,uint8 (>=4<=12),K,true,number.boiler_dhw_eco_diff,number.boiler_dhw_ecodiff,5,9,1,-1,1
|
||||
"Geo 5xx",boiler,173,ecoplusdiff,eco+ diff,uint8 (>=6<=12),K,true,number.boiler_dhw_eco+_diff,number.boiler_dhw_ecoplusdiff,5,9,1,-1,1
|
||||
"Geo 5xx",boiler,173,comfstop,comfort stop temp,uint8 (>=0<=254),C,true,number.boiler_dhw_comfort_stop_temp,number.boiler_dhw_comfstop,5,9,1,-1,1
|
||||
"Geo 5xx",boiler,173,ecostop,eco stop temp,uint8 (>=0<=254),C,true,number.boiler_dhw_eco_stop_temp,number.boiler_dhw_ecostop,5,9,1,-1,1
|
||||
|
||||
|
Can't render this file because it is too large.
|
@@ -524,8 +524,8 @@ const std::initializer_list<Modbus::EntityModbusInfo> Modbus::modbus_register_ma
|
||||
REGISTER_MAPPING(dt::SWITCH, TAG_TYPE_DEVICE_DATA, FL_(flowTempHc), 1, 1), // flowtemphc
|
||||
REGISTER_MAPPING(dt::SWITCH, TAG_TYPE_DEVICE_DATA, FL_(status), 2, 1), // status
|
||||
REGISTER_MAPPING(dt::CONTROLLER, TAG_TYPE_DEVICE_DATA, FL_(dateTime), 0, 13), // datetime
|
||||
REGISTER_MAPPING(dt::CONNECT, TAG_TYPE_DEVICE_DATA, FL_(dateTime), 0, 15), // datetime
|
||||
REGISTER_MAPPING(dt::CONNECT, TAG_TYPE_DEVICE_DATA, FL_(outdoorTemp), 15, 1), // outdoortemp
|
||||
REGISTER_MAPPING(dt::CONNECT, TAG_TYPE_DEVICE_DATA, FL_(dateTime), 0, 13), // datetime
|
||||
REGISTER_MAPPING(dt::CONNECT, TAG_TYPE_DEVICE_DATA, FL_(outdoorTemp), 13, 1), // outdoortemp
|
||||
REGISTER_MAPPING(dt::ALERT, TAG_TYPE_DEVICE_DATA, FL_(setFlowTemp), 0, 1), // setflowtemp
|
||||
REGISTER_MAPPING(dt::ALERT, TAG_TYPE_DEVICE_DATA, FL_(setBurnPow), 1, 1), // setburnpow
|
||||
REGISTER_MAPPING(dt::EXTENSION, TAG_TYPE_DEVICE_DATA, FL_(flowTempVf), 0, 1), // flowtempvf
|
||||
|
||||