mirror of
https://github.com/emsesp/EMS-ESP32.git
synced 2025-12-07 00:09:51 +03:00
Merge pull request #40 from geezerrr/patch-1
This commit is contained in:
@@ -1,17 +1,17 @@
|
||||
- platform: mqtt
|
||||
state_topic: 'home/esp-esp/thermostat_data'
|
||||
state_topic: 'home/ems-esp/thermostat_data'
|
||||
name: 'Current Room Temperature'
|
||||
unit_of_measurement: '°C'
|
||||
value_template: "{{ value_json.thermostat_currtemp }}"
|
||||
|
||||
- platform: mqtt
|
||||
state_topic: 'home/esp-esp/thermostat_data'
|
||||
state_topic: 'home/ems-esp/thermostat_data'
|
||||
name: 'Current Set Temperature'
|
||||
unit_of_measurement: '°C'
|
||||
value_template: "{{ value_json.thermostat_seltemp }}"
|
||||
|
||||
- platform: mqtt
|
||||
state_topic: 'home/esp-esp/thermostat_data'
|
||||
state_topic: 'home/ems-esp/thermostat_data'
|
||||
name: 'Current Mode'
|
||||
value_template: "{{ value_json.thermostat_mode }}"
|
||||
|
||||
@@ -22,117 +22,117 @@
|
||||
value_template: '{{ as_timestamp(states.automation.see_if_boiler_restarts.attributes.last_triggered) | timestamp_custom("%H:%M:%S %d/%m/%y") }}'
|
||||
|
||||
- platform: mqtt
|
||||
state_topic: 'home/esp-esp/showertime'
|
||||
state_topic: 'home/ems-esp/showertime'
|
||||
name: 'Last shower duration'
|
||||
force_update: true
|
||||
|
||||
- platform: mqtt
|
||||
state_topic: 'home/esp-esp/boiler_data'
|
||||
state_topic: 'home/ems-esp/boiler_data'
|
||||
name: 'Tap Water'
|
||||
value_template: '{{ value_json.tapwaterActive }}'
|
||||
|
||||
- platform: mqtt
|
||||
state_topic: 'home/esp-esp/boiler_data'
|
||||
state_topic: 'home/ems-esp/boiler_data'
|
||||
name: 'Heating'
|
||||
value_template: '{{ value_json.heatingActive }}'
|
||||
|
||||
- platform: mqtt
|
||||
state_topic: 'home/esp-esp/boiler_data'
|
||||
state_topic: 'home/ems-esp/boiler_data'
|
||||
name: 'Warm Water selected temperature'
|
||||
unit_of_measurement: '°C'
|
||||
value_template: '{{ value_json.wWSelTemp }}'
|
||||
|
||||
- platform: mqtt
|
||||
state_topic: 'home/esp-esp/boiler_data'
|
||||
state_topic: 'home/ems-esp/boiler_data'
|
||||
name: 'Warm Water tapwater flow rate'
|
||||
unit_of_measurement: 'l/min'
|
||||
value_template: '{{ value_json.wWCurFlow }}'
|
||||
|
||||
- platform: mqtt
|
||||
state_topic: 'home/esp-esp/boiler_data'
|
||||
state_topic: 'home/ems-esp/boiler_data'
|
||||
name: 'Warm Water current temperature'
|
||||
unit_of_measurement: '°C'
|
||||
value_template: '{{ value_json.wWCurTmp }}'
|
||||
|
||||
- platform: mqtt
|
||||
state_topic: 'home/esp-esp/boiler_data'
|
||||
state_topic: 'home/ems-esp/boiler_data'
|
||||
name: 'Warm Water activated'
|
||||
value_template: '{{ value_json.wWActivated }}'
|
||||
|
||||
- platform: mqtt
|
||||
state_topic: 'home/esp-esp/boiler_data'
|
||||
state_topic: 'home/ems-esp/boiler_data'
|
||||
name: 'Warm Water 3-way valve'
|
||||
value_template: '{{ value_json.wWHeat }}'
|
||||
|
||||
- platform: mqtt
|
||||
state_topic: 'home/esp-esp/boiler_data'
|
||||
state_topic: 'home/ems-esp/boiler_data'
|
||||
name: 'Current flow temperature'
|
||||
unit_of_measurement: '°C'
|
||||
value_template: '{{ value_json.curFlowTemp }}'
|
||||
|
||||
- platform: mqtt
|
||||
state_topic: 'home/esp-esp/boiler_data'
|
||||
state_topic: 'home/ems-esp/boiler_data'
|
||||
name: 'Return temperature'
|
||||
unit_of_measurement: '°C'
|
||||
value_template: '{{ value_json.retTemp }}'
|
||||
|
||||
- platform: mqtt
|
||||
state_topic: 'home/esp-esp/boiler_data'
|
||||
state_topic: 'home/ems-esp/boiler_data'
|
||||
name: 'Gas'
|
||||
value_template: '{{ value_json.burnGas }}'
|
||||
|
||||
- platform: mqtt
|
||||
state_topic: 'home/esp-esp/boiler_data'
|
||||
state_topic: 'home/ems-esp/boiler_data'
|
||||
name: 'Boiler pump'
|
||||
value_template: '{{ value_json.heatPmp }}'
|
||||
|
||||
- platform: mqtt
|
||||
state_topic: 'home/esp-esp/boiler_data'
|
||||
state_topic: 'home/ems-esp/boiler_data'
|
||||
name: 'Fan'
|
||||
value_template: '{{ value_json.fanWork }}'
|
||||
|
||||
- platform: mqtt
|
||||
state_topic: 'home/esp-esp/boiler_data'
|
||||
state_topic: 'home/ems-esp/boiler_data'
|
||||
name: 'Ignition'
|
||||
value_template: '{{ value_json.ignWork }}'
|
||||
|
||||
- platform: mqtt
|
||||
state_topic: 'home/esp-esp/boiler_data'
|
||||
state_topic: 'home/ems-esp/boiler_data'
|
||||
name: 'Circulation pump'
|
||||
value_template: '{{ value_json.wWCirc }}'
|
||||
|
||||
- platform: mqtt
|
||||
state_topic: 'home/esp-esp/boiler_data'
|
||||
state_topic: 'home/ems-esp/boiler_data'
|
||||
name: 'Burner max power'
|
||||
unit_of_measurement: '%'
|
||||
value_template: '{{ value_json.selBurnPow }}'
|
||||
|
||||
- platform: mqtt
|
||||
state_topic: 'home/esp-esp/boiler_data'
|
||||
state_topic: 'home/ems-esp/boiler_data'
|
||||
name: 'Burner max power'
|
||||
unit_of_measurement: '%'
|
||||
value_template: '{{ value_json.selBurnPow }}'
|
||||
|
||||
- platform: mqtt
|
||||
state_topic: 'home/esp-esp/boiler_data'
|
||||
state_topic: 'home/ems-esp/boiler_data'
|
||||
name: 'Burner current power'
|
||||
unit_of_measurement: '%'
|
||||
value_template: '{{ value_json.curBurnPow }}'
|
||||
|
||||
- platform: mqtt
|
||||
state_topic: 'home/esp-esp/boiler_data'
|
||||
state_topic: 'home/ems-esp/boiler_data'
|
||||
name: 'System Pressure'
|
||||
unit_of_measurement: 'bar'
|
||||
value_template: '{{ value_json.sysPress }}'
|
||||
|
||||
- platform: mqtt
|
||||
state_topic: 'home/esp-esp/boiler_data'
|
||||
state_topic: 'home/ems-esp/boiler_data'
|
||||
name: 'Boiler temperature'
|
||||
unit_of_measurement: '°C'
|
||||
value_template: '{{ value_json.boilTemp }}'
|
||||
|
||||
- platform: mqtt
|
||||
state_topic: 'home/esp-esp/boiler_data'
|
||||
state_topic: 'home/ems-esp/boiler_data'
|
||||
name: 'Pump modulation'
|
||||
unit_of_measurement: '%'
|
||||
value_template: '{{ value_json.pumpMod }}'
|
||||
|
||||
Reference in New Issue
Block a user