mirror of
https://github.com/emsesp/EMS-ESP32.git
synced 2025-12-07 16:29:51 +03:00
add enable ADC, add boiler circulation commands, add thermostat RC300 summermodes
This commit is contained in:
@@ -33,17 +33,17 @@ Boiler::Boiler(uint8_t device_type, int8_t device_id, uint8_t product_id, const
|
||||
// the telegram handlers...
|
||||
register_telegram_type(0x10, F("UBAErrorMessage1"), false, [&](std::shared_ptr<const Telegram> t) { process_UBAErrorMessage(t); });
|
||||
register_telegram_type(0x11, F("UBAErrorMessage2"), false, [&](std::shared_ptr<const Telegram> t) { process_UBAErrorMessage(t); });
|
||||
register_telegram_type(0x14, F("UBATotalUptime"), true, [&](std::shared_ptr<const Telegram> t) { process_UBATotalUptime(t); });
|
||||
register_telegram_type(0x15, F("UBAMaintenanceData"), false, [&](std::shared_ptr<const Telegram> t) { process_UBAMaintenanceData(t); });
|
||||
register_telegram_type(0x16, F("UBAParameters"), true, [&](std::shared_ptr<const Telegram> t) { process_UBAParameters(t); });
|
||||
register_telegram_type(0x18, F("UBAMonitorFast"), false, [&](std::shared_ptr<const Telegram> t) { process_UBAMonitorFast(t); });
|
||||
register_telegram_type(0x19, F("UBAMonitorSlow"), true, [&](std::shared_ptr<const Telegram> t) { process_UBAMonitorSlow(t); });
|
||||
register_telegram_type(0x34, F("UBAMonitorWW"), false, [&](std::shared_ptr<const Telegram> t) { process_UBAMonitorWW(t); });
|
||||
register_telegram_type(0x1A, F("UBASetPoints"), false, [&](std::shared_ptr<const Telegram> t) { process_UBASetPoints(t); });
|
||||
register_telegram_type(0x1C, F("UBAMaintenanceStatus"), false, [&](std::shared_ptr<const Telegram> t) { process_UBAMaintenanceStatus(t); });
|
||||
register_telegram_type(0x2A, F("MC10Status"), false, [&](std::shared_ptr<const Telegram> t) { process_MC10Status(t); });
|
||||
register_telegram_type(0x33, F("UBAParameterWW"), true, [&](std::shared_ptr<const Telegram> t) { process_UBAParameterWW(t); });
|
||||
register_telegram_type(0x14, F("UBATotalUptime"), true, [&](std::shared_ptr<const Telegram> t) { process_UBATotalUptime(t); });
|
||||
register_telegram_type(0x34, F("UBAMonitorWW"), false, [&](std::shared_ptr<const Telegram> t) { process_UBAMonitorWW(t); });
|
||||
register_telegram_type(0x35, F("UBAFlags"), false, [&](std::shared_ptr<const Telegram> t) { process_UBAFlags(t); });
|
||||
register_telegram_type(0x15, F("UBAMaintenanceData"), false, [&](std::shared_ptr<const Telegram> t) { process_UBAMaintenanceData(t); });
|
||||
register_telegram_type(0x16, F("UBAParameters"), true, [&](std::shared_ptr<const Telegram> t) { process_UBAParameters(t); });
|
||||
register_telegram_type(0x1A, F("UBASetPoints"), false, [&](std::shared_ptr<const Telegram> t) { process_UBASetPoints(t); });
|
||||
register_telegram_type(0xD1, F("UBAOutdoorTemp"), false, [&](std::shared_ptr<const Telegram> t) { process_UBAOutdoorTemp(t); });
|
||||
register_telegram_type(0xE3, F("UBAMonitorSlowPlus"), false, [&](std::shared_ptr<const Telegram> t) { process_UBAMonitorSlowPlus2(t); });
|
||||
register_telegram_type(0xE4, F("UBAMonitorFastPlus"), false, [&](std::shared_ptr<const Telegram> t) { process_UBAMonitorFastPlus(t); });
|
||||
@@ -57,7 +57,9 @@ Boiler::Boiler(uint8_t device_type, int8_t device_id, uint8_t product_id, const
|
||||
register_mqtt_cmd(F("wwactivated"), [&](const char * value, const int8_t id) { return set_warmwater_activated(value, id); });
|
||||
register_mqtt_cmd(F("wwtapactivated"), [&](const char * value, const int8_t id) { return set_tapwarmwater_activated(value, id); });
|
||||
register_mqtt_cmd(F("wwonetime"), [&](const char * value, const int8_t id) { return set_warmwater_onetime(value, id); });
|
||||
register_mqtt_cmd(F("wwcircpump"), [&](const char * value, const int8_t id) { return set_warmwater_circulation_pump(value, id); });
|
||||
register_mqtt_cmd(F("wwcirculation"), [&](const char * value, const int8_t id) { return set_warmwater_circulation(value, id); });
|
||||
register_mqtt_cmd(F("wwcircmode"), [&](const char * value, const int8_t id) { return set_warmwater_circulation_mode(value, id); });
|
||||
register_mqtt_cmd(F("flowtemp"), [&](const char * value, const int8_t id) { return set_flow_temp(value, id); });
|
||||
register_mqtt_cmd(F("wwtemp"), [&](const char * value, const int8_t id) { return set_warmwater_temp(value, id); });
|
||||
register_mqtt_cmd(F("heatingactivated"), [&](const char * value, const int8_t id) { return set_heating_activated(value, id); });
|
||||
@@ -237,8 +239,8 @@ bool Boiler::export_values(JsonObject & output) {
|
||||
if (Helpers::hasValue(wWDisinfecting_, EMS_VALUE_BOOL)) {
|
||||
output["wWDisinfecting"] = Helpers::render_value(s, wWDisinfecting_, EMS_VALUE_BOOL);
|
||||
}
|
||||
if (Helpers::hasValue(wWReadiness_, EMS_VALUE_BOOL)) {
|
||||
output["wWReady"] = Helpers::render_value(s, wWReadiness_, EMS_VALUE_BOOL);
|
||||
if (Helpers::hasValue(wWCharging_, EMS_VALUE_BOOL)) {
|
||||
output["wWCharge"] = Helpers::render_value(s, wWCharging_, EMS_VALUE_BOOL);
|
||||
}
|
||||
if (Helpers::hasValue(wWRecharging_, EMS_VALUE_BOOL)) {
|
||||
output["wWRecharge"] = Helpers::render_value(s, wWRecharging_, EMS_VALUE_BOOL);
|
||||
@@ -246,8 +248,8 @@ bool Boiler::export_values(JsonObject & output) {
|
||||
if (Helpers::hasValue(wWTemperatureOK_, EMS_VALUE_BOOL)) {
|
||||
output["wWTempOK"] = Helpers::render_value(s, wWTemperatureOK_, EMS_VALUE_BOOL);
|
||||
}
|
||||
if (Helpers::hasValue(wWCirc_, EMS_VALUE_BOOL)) {
|
||||
output["wWCirc"] = Helpers::render_value(s, wWCirc_, EMS_VALUE_BOOL);
|
||||
if (Helpers::hasValue(wWActive_, EMS_VALUE_BOOL)) {
|
||||
output["wWActive"] = Helpers::render_value(s, wWActive_, EMS_VALUE_BOOL);
|
||||
}
|
||||
if (Helpers::hasValue(burnGas_, EMS_VALUE_BOOL)) {
|
||||
output["burnGas"] = Helpers::render_value(s, burnGas_, EMS_VALUE_BOOL);
|
||||
@@ -480,14 +482,14 @@ void Boiler::show_values(uuid::console::Shell & shell) {
|
||||
*/
|
||||
void Boiler::check_active() {
|
||||
if ((boilerState_ & 0x09) != (last_boilerState & 0x09)) {
|
||||
char s[5];
|
||||
char s[7];
|
||||
bool b = ((boilerState_ & 0x09) == 0x09);
|
||||
Mqtt::publish(F("heating_active"), Helpers::render_boolean(s, b));
|
||||
heating_active_ = b ? EMS_VALUE_BOOL_ON : EMS_VALUE_BOOL_OFF;
|
||||
}
|
||||
|
||||
if ((boilerState_ & 0x0A) != (last_boilerState & 0x0A)) {
|
||||
char s[5];
|
||||
char s[7];
|
||||
bool b = ((boilerState_ & 0x0A) == 0x0A);
|
||||
Mqtt::publish(F("tapwater_active"), Helpers::render_boolean(s, b));
|
||||
tap_water_active_ = b ? EMS_VALUE_BOOL_ON : EMS_VALUE_BOOL_OFF;
|
||||
@@ -497,7 +499,6 @@ void Boiler::check_active() {
|
||||
last_boilerState = boilerState_;
|
||||
|
||||
/*
|
||||
|
||||
// hot tap water, using flow to check instead of the burner power
|
||||
// send these values back to the main EMSESP, so other classes (e.g. Shower) can use it
|
||||
if (Helpers::hasValue(wWCurFlow_) && Helpers::hasValue(burnGas_) && (wWType_ > 0) && (wWType_ < 3)) {
|
||||
@@ -613,9 +614,10 @@ void Boiler::process_UBAMonitorWW(std::shared_ptr<const Telegram> telegram) {
|
||||
|
||||
changed_ |= telegram->read_bitvalue(wWOneTime_, 5, 1);
|
||||
changed_ |= telegram->read_bitvalue(wWDisinfecting_, 5, 2);
|
||||
changed_ |= telegram->read_bitvalue(wWReadiness_, 5, 3);
|
||||
changed_ |= telegram->read_bitvalue(wWCharging_, 5, 3);
|
||||
changed_ |= telegram->read_bitvalue(wWRecharging_, 5, 4);
|
||||
changed_ |= telegram->read_bitvalue(wWTemperatureOK_, 5, 5);
|
||||
changed_ |= telegram->read_bitvalue(wWActive_, 5, 6);
|
||||
}
|
||||
|
||||
/*
|
||||
@@ -715,7 +717,7 @@ void Boiler::process_UBADHWStatus(std::shared_ptr<const Telegram> telegram) {
|
||||
|
||||
changed_ |= telegram->read_bitvalue(wWOneTime_, 12, 2);
|
||||
changed_ |= telegram->read_bitvalue(wWDisinfecting_, 12, 3);
|
||||
changed_ |= telegram->read_bitvalue(wWReadiness_, 12, 4);
|
||||
changed_ |= telegram->read_bitvalue(wWCharging_, 12, 4);
|
||||
changed_ |= telegram->read_bitvalue(wWRecharging_, 13, 4);
|
||||
changed_ |= telegram->read_bitvalue(wWTemperatureOK_, 13, 5);
|
||||
changed_ |= telegram->read_bitvalue(wWCircPump_, 13, 2);
|
||||
@@ -816,7 +818,7 @@ bool Boiler::set_heating_activated(const char * value, const int8_t id) {
|
||||
return false;
|
||||
}
|
||||
|
||||
LOG_INFO(F("Setting boiler heating "), v ? "on" : "off");
|
||||
LOG_INFO(F("Setting boiler heating %s"), v ? "on" : "off");
|
||||
if (get_toggle_fetch(EMS_TYPE_UBAParametersPlus)) {
|
||||
write_command(EMS_TYPE_UBAParametersPlus, 0, v ? 0x01 : 0, EMS_TYPE_UBAParametersPlus);
|
||||
} else {
|
||||
@@ -992,7 +994,7 @@ bool Boiler::set_warmwater_activated(const char * value, const int8_t id) {
|
||||
if (get_toggle_fetch(EMS_TYPE_UBAParameterWWPlus)) {
|
||||
write_command(EMS_TYPE_UBAParameterWWPlus, 1, v ? 1 : 0, EMS_TYPE_UBAParameterWWPlus);
|
||||
} else {
|
||||
write_command(EMS_TYPE_UBAParameterWW, 1, n, EMS_TYPE_UBAParameterWW);
|
||||
write_command(EMS_TYPE_UBAParameterWW, 1, n, 0x34);
|
||||
}
|
||||
|
||||
return true;
|
||||
@@ -1024,7 +1026,6 @@ bool Boiler::set_tapwarmwater_activated(const char * value, const int8_t id) {
|
||||
} else {
|
||||
// get out of test mode. Send all zeros.
|
||||
// telegram: 0B 08 1D 00 00
|
||||
message_data[4] = 0x00; // test mode off
|
||||
}
|
||||
|
||||
write_command(EMS_TYPE_UBAFunctionTest, 0, message_data, sizeof(message_data), 0);
|
||||
@@ -1069,4 +1070,42 @@ bool Boiler::set_warmwater_circulation(const char * value, const int8_t id) {
|
||||
return true;
|
||||
}
|
||||
|
||||
// configuration of warm water circulation pump
|
||||
bool Boiler::set_warmwater_circulation_pump(const char * value, const int8_t id) {
|
||||
bool v = false;
|
||||
if (!Helpers::value2bool(value, v)) {
|
||||
return false;
|
||||
}
|
||||
|
||||
LOG_INFO(F("Setting boiler warm water circulation %s"), v ? "on" : "off");
|
||||
|
||||
if (get_toggle_fetch(EMS_TYPE_UBAParameterWWPlus)) {
|
||||
write_command(EMS_TYPE_UBAParameterWWPlus, 10, v ? 0x01 : 0x00, EMS_TYPE_UBAParameterWWPlus);
|
||||
} else {
|
||||
write_command(EMS_TYPE_UBAParameterWW, 6, v ? 0xFF : 0x00, EMS_TYPE_UBAParameterWW);
|
||||
}
|
||||
|
||||
return true;
|
||||
}
|
||||
|
||||
// Set the mode of circulation, 1x3min, ... 6x3min, continous
|
||||
// true = on, false = off
|
||||
bool Boiler::set_warmwater_circulation_mode(const char * value, const int8_t id) {
|
||||
int v = 0;
|
||||
if (!Helpers::value2number(value, v)) {
|
||||
return false;
|
||||
}
|
||||
|
||||
if (get_toggle_fetch(EMS_TYPE_UBAParameterWW)) {
|
||||
if (v < 7) {
|
||||
LOG_INFO(F("Setting circulation mode %dx3min"), v);
|
||||
} else {
|
||||
LOG_INFO(F("Setting circulation mode continous"));
|
||||
}
|
||||
write_command(EMS_TYPE_UBAParameterWW, 6, v, EMS_TYPE_UBAParameterWW);
|
||||
}
|
||||
|
||||
return true;
|
||||
}
|
||||
|
||||
} // namespace emsesp
|
||||
|
||||
Reference in New Issue