@@ -1477,7 +1477,7 @@ void Boiler::process_UBAMonitorFastPlus(std::shared_ptr<const Telegram> telegram
// at this point do a quick check to see if the hot water or heating is active // at this point do a quick check to see if the hot water or heating is active
uint8_t state = EMS_VALUE_UINT8_NOTSET; uint8_t state = EMS_VALUE_UINT8_NOTSET;
if (telegram->read_value(state, 11) && model() != EMSdevice::EMS_DEVICE_FLAG_HIU && model() != EMSdevice::EMS_DEVICE_FLAG_HEATPUMP) { if (telegram->read_value(state, 11) && model() != EMSdevice::EMS_DEVICE_FLAG_HIU && !isHeatPump()) {
boilerState_ = state & 0x01 ? 0x08 : 0; // burnGas boilerState_ = state & 0x01 ? 0x08 : 0; // burnGas
boilerState_ |= state & 0x02 ? 0x01 : 0; // heatingPump boilerState_ |= state & 0x02 ? 0x01 : 0; // heatingPump
boilerState_ |= state & 0x04 ? 0x02 : 0; // 3-way-valve boilerState_ |= state & 0x04 ? 0x02 : 0; // 3-way-valve