@@ -10,9 +10,12 @@
|
||||
- telegrams for RC100H, hc2, etc. (seen on discord, not tested)
|
||||
- names for BC400, GB192i.2, read temperatures for low loss header and heatblock [#1317](https://github.com/emsesp/EMS-ESP32/discussions/1317)
|
||||
- option for `forceheatingoff` [#1262](https://github.com/emsesp/EMS-ESP32/issues/1262)
|
||||
- remote thermostat emulation for RC3xx
|
||||
- remote thermostat emulation RC100H for RC3xx [#1278](https://github.com/emsesp/EMS-ESP32/discussions/1278)
|
||||
- publish time for shower
|
||||
- autodetect board_profile, store in nvs, add telnet command option, add E32V2
|
||||
- heatpump high res energy counters [#1348, #1349. #1350](https://github.com/emsesp/EMS-ESP32/issues/1348)
|
||||
- optional bssid in network settings
|
||||
- extension module EM100 [#1315](https://github.com/emsesp/EMS-ESP32/discussions/1315)
|
||||
|
||||
## Fixed
|
||||
|
||||
@@ -24,3 +27,6 @@
|
||||
|
||||
- update to platform 6.4.0, arduino 2.0.14 / idf 4.4.6
|
||||
- small changes for arduino 3.0.0 / idf 5.1 compatibility (not backward compatible to platform 6.3.2 and before)
|
||||
- AP start after 10 sec, stay until station/eth connected
|
||||
- tested wifi-all-channel-scan (3.6.3-dev4 a-e), removed again because of connect issues
|
||||
- mqtt disconnect stops queue
|
||||
|
||||
@@ -285,9 +285,6 @@ Boiler::Boiler(uint8_t device_type, int8_t device_id, uint8_t product_id, const
|
||||
register_device_value(DeviceValueTAG::TAG_DEVICE_DATA, &nrgTotal_, DeviceValueType::ULONG, DeviceValueNumOp::DV_NUMOP_DIV100, FL_(nrgTotal), DeviceValueUOM::KWH);
|
||||
register_device_value(DeviceValueTAG::TAG_BOILER_DATA_WW, &nrgWw_, DeviceValueType::ULONG, DeviceValueNumOp::DV_NUMOP_DIV100, FL_(nrgWw), DeviceValueUOM::KWH);
|
||||
register_device_value(DeviceValueTAG::TAG_DEVICE_DATA, &nrgHeat_, DeviceValueType::ULONG, DeviceValueNumOp::DV_NUMOP_DIV100, FL_(nrgHeat), DeviceValueUOM::KWH);
|
||||
register_device_value(DeviceValueTAG::TAG_DEVICE_DATA, &meterTotal_, DeviceValueType::ULONG, DeviceValueNumOp::DV_NUMOP_DIV100, FL_(meterTotal), DeviceValueUOM::KWH);
|
||||
register_device_value(DeviceValueTAG::TAG_DEVICE_DATA, &meterComp_, DeviceValueType::ULONG, DeviceValueNumOp::DV_NUMOP_DIV100, FL_(meterComp), DeviceValueUOM::KWH);
|
||||
register_device_value(DeviceValueTAG::TAG_DEVICE_DATA, &meterEHeat_, DeviceValueType::ULONG, DeviceValueNumOp::DV_NUMOP_DIV100, FL_(meterEHeat), DeviceValueUOM::KWH);
|
||||
|
||||
/*
|
||||
* Hybrid heatpump with telegram 0xBB is readable and writeable in boiler and thermostat
|
||||
@@ -362,6 +359,24 @@ Boiler::Boiler(uint8_t device_type, int8_t device_id, uint8_t product_id, const
|
||||
|
||||
// heatpump info
|
||||
if (model() == EMS_DEVICE_FLAG_HEATPUMP) {
|
||||
register_device_value(DeviceValueTAG::TAG_DEVICE_DATA,
|
||||
&meterTotal_,
|
||||
DeviceValueType::ULONG,
|
||||
DeviceValueNumOp::DV_NUMOP_DIV100,
|
||||
FL_(meterTotal),
|
||||
DeviceValueUOM::KWH);
|
||||
register_device_value(DeviceValueTAG::TAG_DEVICE_DATA,
|
||||
&meterComp_,
|
||||
DeviceValueType::ULONG,
|
||||
DeviceValueNumOp::DV_NUMOP_DIV100,
|
||||
FL_(meterComp),
|
||||
DeviceValueUOM::KWH);
|
||||
register_device_value(DeviceValueTAG::TAG_DEVICE_DATA,
|
||||
&meterEHeat_,
|
||||
DeviceValueType::ULONG,
|
||||
DeviceValueNumOp::DV_NUMOP_DIV100,
|
||||
FL_(meterEHeat),
|
||||
DeviceValueUOM::KWH);
|
||||
register_device_value(DeviceValueTAG::TAG_DEVICE_DATA,
|
||||
&upTimeControl_,
|
||||
DeviceValueType::TIME,
|
||||
@@ -1019,6 +1034,7 @@ void Boiler::check_active() {
|
||||
nrgWwF_ += ((double)((uint32_t)wwBurnPow * nomPower_ * (uuid::get_uptime() - powLastReadTime_)) / 3600) / 1000UL;
|
||||
has_update(nrgHeat_, (uint32_t)(nrgHeatF_ + 0.5));
|
||||
has_update(nrgWw_, (uint32_t)(nrgWwF_ + 0.5));
|
||||
has_update(nrgTotal_, (uint32_t)(nrgHeatF_ + nrgWwF_ + 0.5));
|
||||
// check for store values
|
||||
time_t now = time(nullptr);
|
||||
tm * tm_ = localtime(&now);
|
||||
|
||||
@@ -1 +1 @@
|
||||
#define EMSESP_APP_VERSION "3.6.3-dev.4f"
|
||||
#define EMSESP_APP_VERSION "3.6.3-dev.4g"
|
||||
|
||||