@@ -136,7 +136,6 @@ Boiler::Boiler(uint8_t device_type, int8_t device_id, uint8_t product_id, const
|
|||||||
register_device_value(TAG_BOILER_DATA, &serviceCode_, DeviceValueType::TEXT, nullptr, FL_(serviceCode), DeviceValueUOM::NONE);
|
register_device_value(TAG_BOILER_DATA, &serviceCode_, DeviceValueType::TEXT, nullptr, FL_(serviceCode), DeviceValueUOM::NONE);
|
||||||
register_device_value(TAG_BOILER_DATA, &serviceCodeNumber_, DeviceValueType::USHORT, nullptr, FL_(serviceCodeNumber), DeviceValueUOM::NONE);
|
register_device_value(TAG_BOILER_DATA, &serviceCodeNumber_, DeviceValueType::USHORT, nullptr, FL_(serviceCodeNumber), DeviceValueUOM::NONE);
|
||||||
register_device_value(TAG_BOILER_DATA, &maintenanceMessage_, DeviceValueType::TEXT, nullptr, FL_(maintenanceMessage), DeviceValueUOM::NONE);
|
register_device_value(TAG_BOILER_DATA, &maintenanceMessage_, DeviceValueType::TEXT, nullptr, FL_(maintenanceMessage), DeviceValueUOM::NONE);
|
||||||
register_device_value(TAG_BOILER_DATA, &maintenanceDate_, DeviceValueType::TEXT, nullptr, FL_(maintenanceDate), DeviceValueUOM::NONE);
|
|
||||||
register_device_value(TAG_BOILER_DATA,
|
register_device_value(TAG_BOILER_DATA,
|
||||||
&maintenanceType_,
|
&maintenanceType_,
|
||||||
DeviceValueType::ENUM,
|
DeviceValueType::ENUM,
|
||||||
@@ -144,7 +143,20 @@ Boiler::Boiler(uint8_t device_type, int8_t device_id, uint8_t product_id, const
|
|||||||
FL_(maintenanceType),
|
FL_(maintenanceType),
|
||||||
DeviceValueUOM::NONE,
|
DeviceValueUOM::NONE,
|
||||||
MAKE_CF_CB(set_maintenance));
|
MAKE_CF_CB(set_maintenance));
|
||||||
register_device_value(TAG_BOILER_DATA, &maintenanceTime_, DeviceValueType::USHORT, nullptr, FL_(maintenanceTime), DeviceValueUOM::HOURS);
|
register_device_value(TAG_BOILER_DATA,
|
||||||
|
&maintenanceTime_,
|
||||||
|
DeviceValueType::USHORT,
|
||||||
|
nullptr,
|
||||||
|
FL_(maintenanceTime),
|
||||||
|
DeviceValueUOM::HOURS,
|
||||||
|
MAKE_CF_CB(set_maintenancetime));
|
||||||
|
register_device_value(TAG_BOILER_DATA,
|
||||||
|
&maintenanceDate_,
|
||||||
|
DeviceValueType::TEXT,
|
||||||
|
nullptr,
|
||||||
|
FL_(maintenanceDate),
|
||||||
|
DeviceValueUOM::NONE,
|
||||||
|
MAKE_CF_CB(set_maintenancedate));
|
||||||
// heatpump info
|
// heatpump info
|
||||||
if (model() == EMS_DEVICE_FLAG_HEATPUMP) {
|
if (model() == EMS_DEVICE_FLAG_HEATPUMP) {
|
||||||
register_device_value(TAG_BOILER_DATA, &upTimeControl_, DeviceValueType::TIME, FL_(div60), FL_(upTimeControl), DeviceValueUOM::MINUTES);
|
register_device_value(TAG_BOILER_DATA, &upTimeControl_, DeviceValueType::TIME, FL_(div60), FL_(upTimeControl), DeviceValueUOM::MINUTES);
|
||||||
@@ -192,6 +204,8 @@ Boiler::Boiler(uint8_t device_type, int8_t device_id, uint8_t product_id, const
|
|||||||
register_device_value(
|
register_device_value(
|
||||||
TAG_BOILER_DATA_WW, &wWCircPump_, DeviceValueType::BOOL, nullptr, FL_(wWCircPump), DeviceValueUOM::BOOLEAN, MAKE_CF_CB(set_warmwater_circulation_pump));
|
TAG_BOILER_DATA_WW, &wWCircPump_, DeviceValueType::BOOL, nullptr, FL_(wWCircPump), DeviceValueUOM::BOOLEAN, MAKE_CF_CB(set_warmwater_circulation_pump));
|
||||||
register_device_value(TAG_BOILER_DATA_WW, &wWChargeType_, DeviceValueType::ENUM, FL_(enum_charge), FL_(wWChargeType), DeviceValueUOM::NONE);
|
register_device_value(TAG_BOILER_DATA_WW, &wWChargeType_, DeviceValueType::ENUM, FL_(enum_charge), FL_(wWChargeType), DeviceValueUOM::NONE);
|
||||||
|
register_device_value(TAG_BOILER_DATA_WW, &wWHystOn_, DeviceValueType::INT, nullptr, FL_(wWHystOn), DeviceValueUOM::DEGREES, MAKE_CF_CB(set_ww_hyst_on));
|
||||||
|
register_device_value(TAG_BOILER_DATA_WW, &wWHystOff_, DeviceValueType::INT, nullptr, FL_(wWHystOff), DeviceValueUOM::DEGREES, MAKE_CF_CB(set_ww_hyst_off));
|
||||||
register_device_value(TAG_BOILER_DATA_WW,
|
register_device_value(TAG_BOILER_DATA_WW,
|
||||||
&wWDisinfectionTemp_,
|
&wWDisinfectionTemp_,
|
||||||
DeviceValueType::UINT,
|
DeviceValueType::UINT,
|
||||||
@@ -315,8 +329,8 @@ void Boiler::process_UBAParameterWW(std::shared_ptr<const Telegram> telegram) {
|
|||||||
// has_update(telegram->read_bitvalue(wwEquipt_,0,3)); // 8=boiler has ww
|
// has_update(telegram->read_bitvalue(wwEquipt_,0,3)); // 8=boiler has ww
|
||||||
has_update(telegram->read_value(wWActivated_, 1)); // 0xFF means on
|
has_update(telegram->read_value(wWActivated_, 1)); // 0xFF means on
|
||||||
has_update(telegram->read_value(wWSelTemp_, 2));
|
has_update(telegram->read_value(wWSelTemp_, 2));
|
||||||
// has_update(telegram->read_value(wW?_, 3)); // Hyst on (default -5)
|
has_update(telegram->read_value(wWHystOn_, 3)); // Hyst on (default -5)
|
||||||
// has_update(telegram->read_value(wW?_, 4)); // (0xFF) Maybe: Hyst off -1?
|
has_update(telegram->read_value(wWHystOff_, 4)); // Hyst off (default -1)
|
||||||
has_update(telegram->read_value(wWFlowTempOffset_, 5)); // default 40
|
has_update(telegram->read_value(wWFlowTempOffset_, 5)); // default 40
|
||||||
has_update(telegram->read_value(wWCircPump_, 6)); // 0xFF means on
|
has_update(telegram->read_value(wWCircPump_, 6)); // 0xFF means on
|
||||||
has_update(telegram->read_value(wWCircMode_, 7)); // 1=1x3min 6=6x3min 7=continuous
|
has_update(telegram->read_value(wWCircMode_, 7)); // 1=1x3min 6=6x3min 7=continuous
|
||||||
@@ -554,6 +568,8 @@ void Boiler::process_UBAParameterWWPlus(std::shared_ptr<const Telegram> telegram
|
|||||||
11)); // 1=1x3min... 6=6x3min, 7=continuous
|
11)); // 1=1x3min... 6=6x3min, 7=continuous
|
||||||
// has_update(telegram->read_value(wWDisinfectTemp_, 12)); // settings, status in E9
|
// has_update(telegram->read_value(wWDisinfectTemp_, 12)); // settings, status in E9
|
||||||
// has_update(telegram->read_value(wWSelTemp_, 6)); // settings, status in E9
|
// has_update(telegram->read_value(wWSelTemp_, 6)); // settings, status in E9
|
||||||
|
has_update(telegram->read_value(wWHystOn_, 7));
|
||||||
|
has_update(telegram->read_value(wWHystOff_, 8));
|
||||||
}
|
}
|
||||||
|
|
||||||
// 0xE9 - WW monitor ems+
|
// 0xE9 - WW monitor ems+
|
||||||
@@ -902,6 +918,42 @@ bool Boiler::set_max_power(const char * value, const int8_t id) {
|
|||||||
return true;
|
return true;
|
||||||
}
|
}
|
||||||
|
|
||||||
|
// set ww on hysteresis
|
||||||
|
bool Boiler::set_ww_hyst_on(const char * value, const int8_t id) {
|
||||||
|
int v = 0;
|
||||||
|
if (!Helpers::value2number(value, v)) {
|
||||||
|
LOG_WARNING(F("Set ww on hysteresis: Invalid value"));
|
||||||
|
return false;
|
||||||
|
}
|
||||||
|
|
||||||
|
LOG_INFO(F("Setting ww on hysteresis on to %d C"), v);
|
||||||
|
if (get_toggle_fetch(EMS_TYPE_UBAParameterWWPlus)) {
|
||||||
|
write_command(EMS_TYPE_UBAParameterWWPlus, 7, v, EMS_TYPE_UBAParameterWWPlus);
|
||||||
|
} else {
|
||||||
|
write_command(EMS_TYPE_UBAParameterWW, 3, v, EMS_TYPE_UBAParameterWW);
|
||||||
|
}
|
||||||
|
|
||||||
|
return true;
|
||||||
|
}
|
||||||
|
|
||||||
|
// set ww off hysteresis
|
||||||
|
bool Boiler::set_ww_hyst_off(const char * value, const int8_t id) {
|
||||||
|
int v = 0;
|
||||||
|
if (!Helpers::value2number(value, v)) {
|
||||||
|
LOG_WARNING(F("Set ww off hysteresis: Invalid value"));
|
||||||
|
return false;
|
||||||
|
}
|
||||||
|
|
||||||
|
LOG_INFO(F("Setting ww off hysteresis off to %d C"), v);
|
||||||
|
if (get_toggle_fetch(EMS_TYPE_UBAParameterWWPlus)) {
|
||||||
|
write_command(EMS_TYPE_UBAParameterWWPlus, 8, v, EMS_TYPE_UBAParameterWWPlus);
|
||||||
|
} else {
|
||||||
|
write_command(EMS_TYPE_UBAParameterWW, 4, v, EMS_TYPE_UBAParameterWW);
|
||||||
|
}
|
||||||
|
|
||||||
|
return true;
|
||||||
|
}
|
||||||
|
|
||||||
// set warm water max power
|
// set warm water max power
|
||||||
bool Boiler::set_warmwater_maxpower(const char * value, const int8_t id) {
|
bool Boiler::set_warmwater_maxpower(const char * value, const int8_t id) {
|
||||||
int v = 0;
|
int v = 0;
|
||||||
@@ -1268,5 +1320,40 @@ bool Boiler::set_maintenance(const char * value, const int8_t id) {
|
|||||||
LOG_WARNING(F("Setting maintenance: wrong format"));
|
LOG_WARNING(F("Setting maintenance: wrong format"));
|
||||||
return false;
|
return false;
|
||||||
}
|
}
|
||||||
|
//maintenance
|
||||||
|
bool Boiler::set_maintenancetime(const char * value, const int8_t id) {
|
||||||
|
int hrs;
|
||||||
|
if (Helpers::value2number(value, hrs)) {
|
||||||
|
if (hrs > 99 && hrs < 25600) {
|
||||||
|
LOG_INFO(F("Setting maintenance time %d hours"), hrs);
|
||||||
|
uint8_t data[2] = {1, (uint8_t)(hrs / 100)};
|
||||||
|
write_command(0x15, 0, data, 2, 0x15);
|
||||||
|
return true;
|
||||||
|
}
|
||||||
|
}
|
||||||
|
LOG_WARNING(F("Setting maintenance: wrong format"));
|
||||||
|
return false;
|
||||||
|
}
|
||||||
|
|
||||||
|
//maintenance
|
||||||
|
bool Boiler::set_maintenancedate(const char * value, const int8_t id) {
|
||||||
|
if (strlen(value) == 10) { // date
|
||||||
|
uint8_t day = (value[0] - '0') * 10 + (value[1] - '0');
|
||||||
|
uint8_t month = (value[3] - '0') * 10 + (value[4] - '0');
|
||||||
|
uint8_t year = (uint8_t)(Helpers::atoint(&value[6]) - 2000);
|
||||||
|
if (day > 0 && day < 32 && month > 0 && month < 13) {
|
||||||
|
LOG_INFO(F("Setting maintenance date to %02d.%02d.%04d"), day, month, year + 2000);
|
||||||
|
uint8_t data[5] = {2, (uint8_t)(maintenanceTime_ / 100), day, month, year};
|
||||||
|
write_command(0x15, 0, data, 5, 0x15);
|
||||||
|
} else {
|
||||||
|
LOG_WARNING(F("Setting maintenance: wrong format %d.%d.%d"), day, month, year + 2000);
|
||||||
|
return false;
|
||||||
|
}
|
||||||
|
return true;
|
||||||
|
}
|
||||||
|
|
||||||
|
LOG_WARNING(F("Setting maintenance: wrong format"));
|
||||||
|
return false;
|
||||||
|
}
|
||||||
|
|
||||||
} // namespace emsesp
|
} // namespace emsesp
|
||||||
|
|||||||
@@ -83,6 +83,8 @@ class Boiler : public EMSdevice {
|
|||||||
uint32_t wWStarts_; // Warm Water # starts
|
uint32_t wWStarts_; // Warm Water # starts
|
||||||
uint32_t wWStarts2_; // Warm water control starts
|
uint32_t wWStarts2_; // Warm water control starts
|
||||||
uint32_t wWWorkM_; // Warm Water # minutes
|
uint32_t wWWorkM_; // Warm Water # minutes
|
||||||
|
int8_t wWHystOn_;
|
||||||
|
int8_t wWHystOff_;
|
||||||
|
|
||||||
uint16_t mixerTemp_; // mixing temperature
|
uint16_t mixerTemp_; // mixing temperature
|
||||||
uint16_t tankMiddleTemp_; // Tank middle temperature (TS3)
|
uint16_t tankMiddleTemp_; // Tank middle temperature (TS3)
|
||||||
@@ -220,6 +222,10 @@ class Boiler : public EMSdevice {
|
|||||||
bool set_pump_delay(const char * value, const int8_t id);
|
bool set_pump_delay(const char * value, const int8_t id);
|
||||||
bool set_reset(const char * value, const int8_t id);
|
bool set_reset(const char * value, const int8_t id);
|
||||||
bool set_maintenance(const char * value, const int8_t id);
|
bool set_maintenance(const char * value, const int8_t id);
|
||||||
|
bool set_maintenancetime(const char * value, const int8_t id);
|
||||||
|
bool set_maintenancedate(const char * value, const int8_t id);
|
||||||
|
bool set_ww_hyst_on(const char * value, const int8_t id);
|
||||||
|
bool set_ww_hyst_off(const char * value, const int8_t id);
|
||||||
};
|
};
|
||||||
|
|
||||||
} // namespace emsesp
|
} // namespace emsesp
|
||||||
|
|||||||
@@ -463,6 +463,8 @@ MAKE_PSTR_LIST(tankMiddleTemp, F("tankmiddletemp"), F("ww tank middle temperatur
|
|||||||
MAKE_PSTR_LIST(wWStarts, F("wwstarts"), F("ww # starts"))
|
MAKE_PSTR_LIST(wWStarts, F("wwstarts"), F("ww # starts"))
|
||||||
MAKE_PSTR_LIST(wWStarts2, F("wwstarts2"), F("ww # control starts"))
|
MAKE_PSTR_LIST(wWStarts2, F("wwstarts2"), F("ww # control starts"))
|
||||||
MAKE_PSTR_LIST(wWWorkM, F("wwworkm"), F("ww active time"))
|
MAKE_PSTR_LIST(wWWorkM, F("wwworkm"), F("ww active time"))
|
||||||
|
MAKE_PSTR_LIST(wWHystOn, F("wwhyston"), F("ww hysteresis on temperature"))
|
||||||
|
MAKE_PSTR_LIST(wWHystOff, F("wwhystoff"), F("ww hysteresis off temperature"))
|
||||||
|
|
||||||
// thermostat
|
// thermostat
|
||||||
// extra commands, with no long name so they don't show up in WebUI
|
// extra commands, with no long name so they don't show up in WebUI
|
||||||
|
|||||||