mirror of
https://github.com/emsesp/EMS-ESP32.git
synced 2025-12-07 16:29:51 +03:00
Web selectbox for enum commands (like bool)
This commit is contained in:
@@ -87,7 +87,7 @@ Boiler::Boiler(uint8_t device_type, int8_t device_id, uint8_t product_id, const
|
||||
// MQTT commands for boiler topic
|
||||
register_device_value(
|
||||
TAG_BOILER_DATA, &wWTapActivated_, DeviceValueType::BOOL, nullptr, FL_(wwtapactivated), DeviceValueUOM::BOOLEAN, MAKE_CF_CB(set_tapwarmwater_activated));
|
||||
register_device_value(TAG_BOILER_DATA, &dummy8u_, DeviceValueType::ENUM, FL_(enum_reset), FL_(reset), DeviceValueUOM::NONE, MAKE_CF_CB(set_reset));
|
||||
register_device_value(TAG_BOILER_DATA, &dummy8u_, DeviceValueType::CMD, FL_(enum_reset), FL_(reset), DeviceValueUOM::LIST, MAKE_CF_CB(set_reset));
|
||||
|
||||
// add values
|
||||
// reserve_device_values(90);
|
||||
@@ -141,7 +141,7 @@ Boiler::Boiler(uint8_t device_type, int8_t device_id, uint8_t product_id, const
|
||||
DeviceValueType::ENUM,
|
||||
FL_(enum_off_time_date),
|
||||
FL_(maintenanceType),
|
||||
DeviceValueUOM::NONE,
|
||||
DeviceValueUOM::LIST,
|
||||
MAKE_CF_CB(set_maintenance));
|
||||
register_device_value(TAG_BOILER_DATA,
|
||||
&maintenanceTime_,
|
||||
@@ -196,14 +196,14 @@ Boiler::Boiler(uint8_t device_type, int8_t device_id, uint8_t product_id, const
|
||||
register_device_value(TAG_BOILER_DATA_WW, &wWSetTemp_, DeviceValueType::UINT, nullptr, FL_(wWSetTemp), DeviceValueUOM::DEGREES, MAKE_CF_CB(set_warmwater_temp));
|
||||
register_device_value(TAG_BOILER_DATA_WW, &wWType_, DeviceValueType::ENUM, FL_(enum_flow), FL_(wWType), DeviceValueUOM::NONE);
|
||||
register_device_value(
|
||||
TAG_BOILER_DATA_WW, &wWComfort_, DeviceValueType::ENUM, FL_(enum_comfort), FL_(wWComfort), DeviceValueUOM::NONE, MAKE_CF_CB(set_warmwater_mode));
|
||||
TAG_BOILER_DATA_WW, &wWComfort_, DeviceValueType::ENUM, FL_(enum_comfort), FL_(wWComfort), DeviceValueUOM::LIST, MAKE_CF_CB(set_warmwater_mode));
|
||||
register_device_value(
|
||||
TAG_BOILER_DATA_WW, &wWFlowTempOffset_, DeviceValueType::UINT, nullptr, FL_(wWFlowTempOffset), DeviceValueUOM::NONE, MAKE_CF_CB(set_wWFlowTempOffset));
|
||||
register_device_value(
|
||||
TAG_BOILER_DATA_WW, &wWMaxPower_, DeviceValueType::UINT, nullptr, FL_(wWMaxPower), DeviceValueUOM::PERCENT, MAKE_CF_CB(set_warmwater_maxpower));
|
||||
register_device_value(
|
||||
TAG_BOILER_DATA_WW, &wWCircPump_, DeviceValueType::BOOL, nullptr, FL_(wWCircPump), DeviceValueUOM::BOOLEAN, MAKE_CF_CB(set_warmwater_circulation_pump));
|
||||
register_device_value(TAG_BOILER_DATA_WW, &wWChargeType_, DeviceValueType::ENUM, FL_(enum_charge), FL_(wWChargeType), DeviceValueUOM::NONE);
|
||||
register_device_value(TAG_BOILER_DATA_WW, &wWChargeType_, DeviceValueType::ENUM, FL_(enum_charge), FL_(wWChargeType), DeviceValueUOM::LIST);
|
||||
register_device_value(TAG_BOILER_DATA_WW, &wWHystOn_, DeviceValueType::INT, nullptr, FL_(wWHystOn), DeviceValueUOM::DEGREES, MAKE_CF_CB(set_ww_hyst_on));
|
||||
register_device_value(TAG_BOILER_DATA_WW, &wWHystOff_, DeviceValueType::INT, nullptr, FL_(wWHystOff), DeviceValueUOM::DEGREES, MAKE_CF_CB(set_ww_hyst_off));
|
||||
register_device_value(TAG_BOILER_DATA_WW,
|
||||
@@ -218,7 +218,7 @@ Boiler::Boiler(uint8_t device_type, int8_t device_id, uint8_t product_id, const
|
||||
DeviceValueType::ENUM,
|
||||
FL_(enum_freq),
|
||||
FL_(wWCircMode),
|
||||
DeviceValueUOM::NONE,
|
||||
DeviceValueUOM::LIST,
|
||||
MAKE_CF_CB(set_warmwater_circulation_mode));
|
||||
register_device_value(TAG_BOILER_DATA_WW, &wWCirc_, DeviceValueType::BOOL, nullptr, FL_(wWCirc), DeviceValueUOM::BOOLEAN, MAKE_CF_CB(set_warmwater_circulation));
|
||||
register_device_value(TAG_BOILER_DATA_WW, &wWCurTemp_, DeviceValueType::USHORT, FL_(div10), FL_(wWCurTemp), DeviceValueUOM::DEGREES);
|
||||
|
||||
Reference in New Issue