change heatingpump2Mod to absBurnPow, #908
This commit is contained in:
@@ -107,7 +107,6 @@ Boiler::Boiler(uint8_t device_type, int8_t device_id, uint8_t product_id, const
|
||||
register_device_value(
|
||||
DeviceValueTAG::TAG_DEVICE_DATA, &selBurnPow_, DeviceValueType::UINT, FL_(selBurnPow), DeviceValueUOM::PERCENT, MAKE_CF_CB(set_burn_power), 0, 254);
|
||||
register_device_value(DeviceValueTAG::TAG_DEVICE_DATA, &heatingPumpMod_, DeviceValueType::UINT, FL_(heatingPumpMod), DeviceValueUOM::PERCENT);
|
||||
register_device_value(DeviceValueTAG::TAG_DEVICE_DATA, &heatingPump2Mod_, DeviceValueType::UINT, FL_(heatingPump2Mod), DeviceValueUOM::PERCENT);
|
||||
register_device_value(DeviceValueTAG::TAG_DEVICE_DATA,
|
||||
&outdoorTemp_,
|
||||
DeviceValueType::SHORT,
|
||||
@@ -184,6 +183,7 @@ Boiler::Boiler(uint8_t device_type, int8_t device_id, uint8_t product_id, const
|
||||
DeviceValueTAG::TAG_DEVICE_DATA, &boil2HystOff_, DeviceValueType::INT, FL_(boil2HystOff), DeviceValueUOM::DEGREES_R, MAKE_CF_CB(set_hyst2_off), 0, 20);
|
||||
register_device_value(DeviceValueTAG::TAG_DEVICE_DATA, &setFlowTemp_, DeviceValueType::UINT, FL_(setFlowTemp), DeviceValueUOM::DEGREES);
|
||||
register_device_value(DeviceValueTAG::TAG_DEVICE_DATA, &setBurnPow_, DeviceValueType::UINT, FL_(setBurnPow), DeviceValueUOM::PERCENT);
|
||||
register_device_value(DeviceValueTAG::TAG_DEVICE_DATA, &absBurnPow_, DeviceValueType::UINT, FL_(absBurnPow), DeviceValueUOM::PERCENT);
|
||||
register_device_value(DeviceValueTAG::TAG_DEVICE_DATA, &curBurnPow_, DeviceValueType::UINT, FL_(curBurnPow), DeviceValueUOM::PERCENT);
|
||||
register_device_value(DeviceValueTAG::TAG_DEVICE_DATA, &burnStarts_, DeviceValueType::ULONG, FL_(burnStarts), DeviceValueUOM::NONE);
|
||||
register_device_value(DeviceValueTAG::TAG_DEVICE_DATA, &burnWorkMin_, DeviceValueType::TIME, FL_(burnWorkMin), DeviceValueUOM::MINUTES);
|
||||
@@ -1055,9 +1055,11 @@ void Boiler::process_UBAMonitorSlow(std::shared_ptr<const Telegram> telegram) {
|
||||
/*
|
||||
* UBAMonitorSlowPlus2 - type 0xE3
|
||||
* 88 00 E3 00 04 00 00 00 00 01 00 00 00 00 00 02 22 2B 64 46 01 00 00 61
|
||||
* https://github.com/Th3M3/buderus_ems-wiki/blob/master/Quelle_08.md
|
||||
* https://github.com/emsesp/EMS-ESP32/issues/908
|
||||
*/
|
||||
void Boiler::process_UBAMonitorSlowPlus2(std::shared_ptr<const Telegram> telegram) {
|
||||
has_update(telegram, heatingPump2Mod_, 13); // Heat Pump Modulation
|
||||
has_update(telegram, absBurnPow_, 13); // current burner absolute power (percent of rating plate power)
|
||||
}
|
||||
|
||||
/*
|
||||
@@ -1956,13 +1958,15 @@ bool Boiler::set_pump_delay(const char * value, const int8_t id) {
|
||||
// note some boilers do not have this setting, than it's done by thermostat
|
||||
// on a RC35 it's by EMSESP::send_write_request(0x37, 0x10, 2, &set, 1, 0); (set is 1,2,3) 1=hot, 2=eco, 3=intelligent
|
||||
// on a RC310 it's 1=high, 2=eco
|
||||
// eco key on controller: tele.05, offset 70: 0xAA =eco, 0x55= comfort, https://github.com/emsesp/EMS-ESP32/issues/908
|
||||
bool Boiler::set_ww_mode(const char * value, const int8_t id) {
|
||||
uint8_t set;
|
||||
uint8_t comfort[] = {0x00, 0xD8, 0xEC};
|
||||
uint8_t comfort[] = {0x00, 0xD8, 0xEC}; // heat, eco, intelligent
|
||||
|
||||
if (is_fetch(EMS_TYPE_UBAParameterWWPlus)) {
|
||||
if (Helpers::value2enum(value, set, FL_(enum_comfort1))) {
|
||||
write_command(EMS_TYPE_UBAParameterWWPlus, 13, comfort[set], EMS_TYPE_UBAParameterWWPlus);
|
||||
write_command(0x05, 70, set ? 0xAA : 0x55); //
|
||||
return true;
|
||||
}
|
||||
} else {
|
||||
|
||||
@@ -98,7 +98,7 @@ class Boiler : public EMSdevice {
|
||||
uint8_t tapwaterActive_; // Hot tap water is on/off
|
||||
uint8_t selFlowTemp_; // Selected flow temperature
|
||||
uint8_t selBurnPow_; // Burner max power % (can be > 100%)
|
||||
uint8_t heatingPump2Mod_; // heatpump modulation from 0xE3 (heatpumps)
|
||||
uint8_t absBurnPow_; // absolute burner power in % of rating plate
|
||||
uint8_t heatingPumpMod_; // Pump modulation %
|
||||
int16_t outdoorTemp_; // Outside temperature
|
||||
uint16_t curFlowTemp_; // Current flow temperature
|
||||
|
||||
@@ -270,8 +270,8 @@ MAKE_PSTR_LIST(heatingActive, "heatingactive", "heating active", "Heizen aktiv",
|
||||
MAKE_PSTR_LIST(tapwaterActive, "tapwateractive", "tapwater active", "Warmwasser aktiv", "Warm water actief", "Varmvatten aktiv", "c.w.u. aktywne", "varmtvann aktiv", "eau chaude active")
|
||||
MAKE_PSTR_LIST(selFlowTemp, "selflowtemp", "selected flow temperature", "Sollwert Vorlauftemperatur", "Ingestelde aanvoertemperatuur", "Börvärde Flödestemperatur", "wybrana temperatura zasilania", "valgt turtemperatur", "température de flux selectionnée")
|
||||
MAKE_PSTR_LIST(selBurnPow, "selburnpow", "burner selected max power", "Sollwert Brennerleistung", "Ingestelde maximale brandervermogen", "Brännare vald maxeffekt", "wybrana moc źródła ciepła", "settpunkt brennerkapasitet", "puissance max du brûleur selectionnée")
|
||||
MAKE_PSTR_LIST(absBurnPow, "absburnpow", "burner current power (absolute)", "Brennerleistung (absolut)", "Brandervermogen (abs)", "Värmepanna aktuell effekt (abs)", "aktualna moc źródła ciepła (abs)", "brennereffekt", "puissance du brûleur actuelle (abs)")
|
||||
MAKE_PSTR_LIST(heatingPumpMod, "heatingpumpmod", "heating pump modulation", "Heizungspumpe 1 Modulation", "Modulatie verwarmingspomp", "Modulering Värmepump", "wysterowanie pompy c.o.", "varmepumpemodulering", "modulation de la pompe à chaleur")
|
||||
MAKE_PSTR_LIST(heatingPump2Mod, "heatingpump2mod", "heating pump 2 modulation", "Heizungspumpe 2 Modulation", "Modulatie verwarmingspomp 2", "Modulering Värmepump 2", "wysterowanie pompy c.o. 2", "varmepumpe 2 modulering", "modulation de la pompe à chaleur 2")
|
||||
MAKE_PSTR_LIST(outdoorTemp, "outdoortemp", "outside temperature", "Aussentemperatur", "Buitentemperatuur", "Utomhustemperatur", "temperatura zewnętrzna", "utetemperatur", "température extérieure")
|
||||
MAKE_PSTR_LIST(curFlowTemp, "curflowtemp", "current flow temperature", "aktuelle Vorlauftemperatur", "Huidige aanvoertemperatuur", "Flödestemperatur", "temperatura zasilania", "aktuell strømmetemperatur", "température actuelle du flux")
|
||||
MAKE_PSTR_LIST(retTemp, "rettemp", "return temperature", "Rücklauftemperatur", "Retourtemperatuur", "Returtemperatur", "temperatura powrotu", "returtemperatur", "température de retour")
|
||||
|
||||