@@ -28,6 +28,7 @@ and this project adheres to [Semantic Versioning](https://semver.org/spec/v2.0.0
|
||||
### Changed
|
||||
- improved MQTT publishing to stop flooding. `publish_time` must be at least 1 (second)
|
||||
- External sensors (like dallas) are sent as a nested MQTT topic including their unqiue identifier
|
||||
- `mqttlog` console command renamed to `mqttqueue`
|
||||
|
||||
### Removed
|
||||
- `autodetect scan`
|
||||
|
||||
23
src/ems.cpp
23
src/ems.cpp
@@ -195,8 +195,10 @@ void ems_init() {
|
||||
// Solar Module values
|
||||
EMS_SolarModule.collectorTemp = EMS_VALUE_SHORT_NOTSET; // collector temp from SM10/SM100/SM200
|
||||
EMS_SolarModule.bottomTemp = EMS_VALUE_SHORT_NOTSET; // bottom temp from SM10/SM100/SM200
|
||||
EMS_SolarModule.bottomTemp2 = EMS_VALUE_SHORT_NOTSET; // bottom temp 2 from SM200
|
||||
EMS_SolarModule.pumpModulation = EMS_VALUE_INT_NOTSET; // modulation solar pump SM10/SM100/SM200
|
||||
EMS_SolarModule.pump = EMS_VALUE_BOOL_NOTSET; // pump active
|
||||
EMS_SolarModule.valveStatus = EMS_VALUE_BOOL_NOTSET; // valve status from SM200
|
||||
EMS_SolarModule.EnergyLastHour = EMS_VALUE_USHORT_NOTSET;
|
||||
EMS_SolarModule.EnergyToday = EMS_VALUE_USHORT_NOTSET;
|
||||
EMS_SolarModule.EnergyTotal = EMS_VALUE_USHORT_NOTSET;
|
||||
@@ -1494,18 +1496,23 @@ void _process_SM10Monitor(_EMS_RxTelegram * EMS_RxTelegram) {
|
||||
}
|
||||
|
||||
/*
|
||||
* SM100Monitor - type 0x0262 EMS+
|
||||
* SM100Monitor - type 0x0262 EMS+ - for SM100 and SM200
|
||||
* e.g. B0 0B FF 00 02 62 00 44 02 7A 80 00 80 00 80 00 80 00 80 00 80 00 00 7C 80 00 80 00 80 00 80
|
||||
* e.g, 30 00 FF 00 02 62 01 AC
|
||||
* 30 00 FF 18 02 62 80 00
|
||||
* 30 00 FF 00 02 62 01 A1 - for bottom temps
|
||||
* bytes 0+1 = TS1 Temperature sensor for collector
|
||||
* bytes 2+3 = TS2 Temperature sensor bottom cylinder 1
|
||||
* bytes 16+17 = TS5 Temperature sensor bottom cylinder 2
|
||||
*/
|
||||
void _process_SM100Monitor(_EMS_RxTelegram * EMS_RxTelegram) {
|
||||
_setValue(EMS_RxTelegram, &EMS_SolarModule.collectorTemp, 0); // is *10
|
||||
_setValue(EMS_RxTelegram, &EMS_SolarModule.bottomTemp, 2); // is *10
|
||||
_setValue(EMS_RxTelegram, &EMS_SolarModule.bottomTemp2, 16); // is *10
|
||||
}
|
||||
|
||||
/*
|
||||
* SM100Status - type 0x0264 EMS+ for pump modulation
|
||||
* SM100Status - type 0x0264 EMS+ for pump modulation - for SM100 and SM200
|
||||
* e.g. 30 00 FF 09 02 64 64 = 100%
|
||||
* 30 00 FF 09 02 64 1E = 30%
|
||||
*/
|
||||
@@ -1514,10 +1521,14 @@ void _process_SM100Status(_EMS_RxTelegram * EMS_RxTelegram) {
|
||||
}
|
||||
|
||||
/*
|
||||
* SM100Status2 - type 0x026A EMS+ for pump on/off at offset 0x0A
|
||||
* SM100Status2 - type 0x026A EMS+ for pump on/off at offset 0x0A - for SM100 and SM200
|
||||
* e.g. B0 00 FF 00 02 6A 03 03 03 03 01 03 03 03 03 03 01 03
|
||||
* byte 4 = VS2 3-way valve for cylinder 2 : test=01, on=04 and off=03
|
||||
* byte 10 = PS1 Solar circuit pump for collector array 1: test=01, on=04 and off=03
|
||||
*/
|
||||
void _process_SM100Status2(_EMS_RxTelegram * EMS_RxTelegram) {
|
||||
_setValue(EMS_RxTelegram, &EMS_SolarModule.pump, 10, 2); // 03=off 04=on
|
||||
_setValue(EMS_RxTelegram, &EMS_SolarModule.valveStatus, 4, 2); // 03=off 04=on
|
||||
_setValue(EMS_RxTelegram, &EMS_SolarModule.pump, 10, 2); // 03=off 04=on
|
||||
}
|
||||
|
||||
/*
|
||||
@@ -1998,7 +2009,7 @@ void ems_getSolarModuleValues() {
|
||||
if (EMS_SolarModule.device_flags == EMS_DEVICE_FLAG_SM10) {
|
||||
ems_doReadCommand(EMS_TYPE_SM10Monitor, EMS_SolarModule.device_id); // fetch all from SM10Monitor
|
||||
} else if (EMS_SolarModule.device_flags == EMS_DEVICE_FLAG_SM100) {
|
||||
ems_doReadCommand(EMS_TYPE_SM100Monitor, EMS_SolarModule.device_id); // fetch all from SM100Monitor
|
||||
ems_doReadCommand(EMS_TYPE_SM100Monitor, EMS_SolarModule.device_id); // fetch all from SM100Monitor (also for SM200)
|
||||
}
|
||||
}
|
||||
}
|
||||
@@ -2823,7 +2834,7 @@ const _EMS_Type EMS_Types[] = {
|
||||
{EMS_DEVICE_UPDATE_FLAG_BOILER, EMS_TYPE_UBAMonitorFast2, "UBAMonitorFast2", _process_UBAMonitorFast2},
|
||||
{EMS_DEVICE_UPDATE_FLAG_BOILER, EMS_TYPE_UBAMonitorSlow2, "UBAMonitorSlow2", _process_UBAMonitorSlow2},
|
||||
|
||||
// Solar Module devices
|
||||
// Solar Module devices. Note SM100 also covers SM200
|
||||
{EMS_DEVICE_UPDATE_FLAG_SOLAR, EMS_TYPE_SM10Monitor, "SM10Monitor", _process_SM10Monitor},
|
||||
{EMS_DEVICE_UPDATE_FLAG_SOLAR, EMS_TYPE_SM100Monitor, "SM100Monitor", _process_SM100Monitor},
|
||||
{EMS_DEVICE_UPDATE_FLAG_SOLAR, EMS_TYPE_SM100Status, "SM100Status", _process_SM100Status},
|
||||
|
||||
40
src/ems.h
40
src/ems.h
@@ -46,22 +46,23 @@
|
||||
#define EMS_MIXING_MAXWWC 2 // max number of warm water circuits
|
||||
|
||||
// Device Flags
|
||||
#define EMS_DEVICE_FLAG_NONE 0 // no flags set
|
||||
#define EMS_DEVICE_FLAG_SM10 10 // solar module1
|
||||
#define EMS_DEVICE_FLAG_SM100 11 // solar module2
|
||||
#define EMS_DEVICE_FLAG_MMPLUS 12 // mixing module EMS+
|
||||
#define EMS_DEVICE_FLAG_MM10 13 // mixing modules MM10 and MM50
|
||||
|
||||
// device flags specific for thermostats
|
||||
#define EMS_DEVICE_FLAG_NO_WRITE 0x80 // top bit set if write not supported
|
||||
#define EMS_DEVICE_FLAG_EASY 1
|
||||
#define EMS_DEVICE_FLAG_RC10 2
|
||||
#define EMS_DEVICE_FLAG_RC20 3
|
||||
#define EMS_DEVICE_FLAG_RC30 4
|
||||
#define EMS_DEVICE_FLAG_RC30N 5 // newer type of RC30 with RC35 circuit
|
||||
#define EMS_DEVICE_FLAG_RC35 6
|
||||
#define EMS_DEVICE_FLAG_RC300 7
|
||||
#define EMS_DEVICE_FLAG_JUNKERS 8
|
||||
// They are unique to the model type (mixing, solar, thermostat etc)
|
||||
enum EMS_DEVICE_FLAG_TYPES : uint8_t {
|
||||
EMS_DEVICE_FLAG_NONE = 0,
|
||||
EMS_DEVICE_FLAG_MMPLUS = 20, // mixing EMS+
|
||||
EMS_DEVICE_FLAG_MM10 = 21, // mixing MM10, MM50
|
||||
EMS_DEVICE_FLAG_SM10 = 10,
|
||||
EMS_DEVICE_FLAG_SM100 = 11, // for SM100 and SM200
|
||||
EMS_DEVICE_FLAG_EASY = 1,
|
||||
EMS_DEVICE_FLAG_RC10 = 2,
|
||||
EMS_DEVICE_FLAG_RC20 = 3,
|
||||
EMS_DEVICE_FLAG_RC30 = 4,
|
||||
EMS_DEVICE_FLAG_RC30N = 5, // newer type of RC30 with RC35 circuit
|
||||
EMS_DEVICE_FLAG_RC35 = 6,
|
||||
EMS_DEVICE_FLAG_RC300 = 7,
|
||||
EMS_DEVICE_FLAG_JUNKERS = (1 << 6), // 6th bit set if its junkers HT3
|
||||
EMS_DEVICE_FLAG_NO_WRITE = (1 << 7) // top bit set if thermostat write not supported
|
||||
};
|
||||
|
||||
typedef enum {
|
||||
EMS_THERMOSTAT_MODE_UNKNOWN,
|
||||
@@ -335,7 +336,6 @@ typedef struct {
|
||||
// calculated values
|
||||
uint8_t tapwaterActive; // Hot tap water is on/off
|
||||
uint8_t heatingActive; // Central heating is on/off
|
||||
|
||||
} _EMS_Boiler;
|
||||
|
||||
/*
|
||||
@@ -388,10 +388,12 @@ typedef struct {
|
||||
const char * device_desc_p;
|
||||
uint8_t product_id;
|
||||
char version[10];
|
||||
int16_t collectorTemp; // collector temp
|
||||
int16_t bottomTemp; // bottom temp
|
||||
int16_t collectorTemp; // collector temp (TS1)
|
||||
int16_t bottomTemp; // bottom temp (TS2)
|
||||
int16_t bottomTemp2; // bottom temp cylinder 2 (TS5)
|
||||
uint8_t pumpModulation; // modulation solar pump
|
||||
uint8_t pump; // pump active
|
||||
uint8_t valveStatus; // valve status (VS2)
|
||||
int16_t setpoint_maxBottomTemp; // setpoint for maximum collector temp
|
||||
uint16_t EnergyLastHour;
|
||||
uint16_t EnergyToday;
|
||||
|
||||
@@ -1 +1 @@
|
||||
#define APP_VERSION "1.9.5b43"
|
||||
#define APP_VERSION "1.9.5b44"
|
||||
|
||||