diff --git a/CHANGELOG_LATEST.md b/CHANGELOG_LATEST.md index 8ff39a6e1..9fa642937 100644 --- a/CHANGELOG_LATEST.md +++ b/CHANGELOG_LATEST.md @@ -24,6 +24,7 @@ - Modules - external linkable module library [#1778](https://github.com/emsesp/EMS-ESP32/issues/1778) - Scheduler onChange and Conditions [#1806](https://github.com/emsesp/EMS-ESP32/issues/1806) - make remote control timeout editable [#1774](https://github.com/emsesp/EMS-ESP32/issues/1774) +- added extra pump characteristics (mode and pressure for EMS+) by @SLTKA [#1802](https://github.com/emsesp/EMS-ESP32/pull/1802) ## Fixed diff --git a/dump_entities.csv b/dump_entities.csv index 764a3da89..da649a62f 100644 --- a/dump_entities.csv +++ b/dump_entities.csv @@ -18,6 +18,7 @@ CS6800i/WLW176i,boiler,8,heatingpump,heating pump,boolean, ,false,binary_sensor. CS6800i/WLW176i,boiler,8,pumpmodmax,boiler pump max power,uint8 (>=0<=100),%,true,number.boiler_boiler_pump_max_power,number.boiler_pumpmodmax CS6800i/WLW176i,boiler,8,pumpmodmin,boiler pump min power,uint8 (>=0<=100),%,true,number.boiler_boiler_pump_min_power,number.boiler_pumpmodmin CS6800i/WLW176i,boiler,8,pumpmode,boiler pump mode,enum [proportional\|deltaP-1\|deltaP-2\|deltaP-3\|deltaP-4], ,true,select.boiler_boiler_pump_mode,select.boiler_pumpmode +CS6800i/WLW176i,boiler,8,pumpcharacter,boiler pump characteristic,enum [proportional\|150mbar\|200mbar\|250mbar\|300mbar\|350mbar\|400mbar], ,true,select.boiler_boiler_pump_characteristic,select.boiler_pumpcharacter CS6800i/WLW176i,boiler,8,pumpdelay,pump delay,uint8 (>=0<=60),minutes,true,number.boiler_pump_delay,number.boiler_pumpdelay CS6800i/WLW176i,boiler,8,setflowtemp,set flow temperature,uint8 (>=0<=254),C,false,sensor.boiler_set_flow_temperature,sensor.boiler_setflowtemp CS6800i/WLW176i,boiler,8,setburnpow,burner set power,uint8 (>=0<=100),%,false,sensor.boiler_burner_set_power,sensor.boiler_setburnpow @@ -39,18 +40,18 @@ CS6800i/WLW176i,boiler,8,maintenancedate,next maintenance date,string, ,true,sen CS6800i/WLW176i,boiler,8,emergencyops,emergency operation,boolean, ,true,switch.boiler_emergency_operation,switch.boiler_emergencyops CS6800i/WLW176i,boiler,8,emergencytemp,emergency temperature,uint8 (>=15<=70),C,true,number.boiler_emergency_temperature,number.boiler_emergencytemp CS6800i/WLW176i,boiler,8,nrgtotal,total energy,uint24 (>=0<=167772),kWh,false,sensor.boiler_total_energy,sensor.boiler_nrgtotal -CS6800i/WLW176i,boiler,8,nrgdhw,energy,uint24 (>=0<=167772),kWh,false,sensor.boiler_dhw_energy,sensor.boiler_dhw_nrgdhw +CS6800i/WLW176i,boiler,8,nrg,energy,uint24 (>=0<=167772),kWh,false,sensor.boiler_dhw_energy,sensor.boiler_dhw_nrg CS6800i/WLW176i,boiler,8,nrgheat,energy heating,uint24 (>=0<=167772),kWh,false,sensor.boiler_energy_heating,sensor.boiler_nrgheat CS6800i/WLW176i,boiler,8,metertotal,meter total,uint24 (>=0<=167772),kWh,false,sensor.boiler_meter_total,sensor.boiler_metertotal CS6800i/WLW176i,boiler,8,metercomp,meter compressor,uint24 (>=0<=167772),kWh,false,sensor.boiler_meter_compressor,sensor.boiler_metercomp CS6800i/WLW176i,boiler,8,metereheat,meter e-heater,uint24 (>=0<=167772),kWh,false,sensor.boiler_meter_e-heater,sensor.boiler_metereheat CS6800i/WLW176i,boiler,8,meterheat,meter heating,uint24 (>=0<=167772),kWh,false,sensor.boiler_meter_heating,sensor.boiler_meterheat -CS6800i/WLW176i,boiler,8,meterdhw,meter,uint24 (>=0<=167772),kWh,false,sensor.boiler_dhw_meter,sensor.boiler_dhw_meterdhw +CS6800i/WLW176i,boiler,8,meter,meter,uint24 (>=0<=167772),kWh,false,sensor.boiler_dhw_meter,sensor.boiler_dhw_meter CS6800i/WLW176i,boiler,8,uptimetotal,heatpump total uptime,time (>=0<=279620),minutes,false,sensor.boiler_heatpump_total_uptime,sensor.boiler_uptimetotal CS6800i/WLW176i,boiler,8,uptimecontrol,total operating time heat,time (>=0<=279620),minutes,false,sensor.boiler_total_operating_time_heat,sensor.boiler_uptimecontrol CS6800i/WLW176i,boiler,8,uptimecompheating,operating time compressor heating,time (>=0<=279620),minutes,false,sensor.boiler_operating_time_compressor_heating,sensor.boiler_uptimecompheating CS6800i/WLW176i,boiler,8,uptimecompcooling,operating time compressor cooling,time (>=0<=279620),minutes,false,sensor.boiler_operating_time_compressor_cooling,sensor.boiler_uptimecompcooling -CS6800i/WLW176i,boiler,8,uptimecompdhw,operating time compressor,time (>=0<=279620),minutes,false,sensor.boiler_dhw_operating_time_compressor,sensor.boiler_dhw_uptimecompdhw +CS6800i/WLW176i,boiler,8,uptimecomp,operating time compressor,time (>=0<=279620),minutes,false,sensor.boiler_dhw_operating_time_compressor,sensor.boiler_dhw_uptimecomp CS6800i/WLW176i,boiler,8,uptimecomppool,operating time compressor pool,time (>=0<=279620),minutes,false,sensor.boiler_operating_time_compressor_pool,sensor.boiler_uptimecomppool CS6800i/WLW176i,boiler,8,totalcompstarts,total compressor control starts,uint24 (>=0<=16777213), ,false,sensor.boiler_total_compressor_control_starts,sensor.boiler_totalcompstarts CS6800i/WLW176i,boiler,8,heatingstarts,heating control starts,uint24 (>=0<=16777213), ,false,sensor.boiler_heating_control_starts,sensor.boiler_heatingstarts @@ -60,16 +61,16 @@ CS6800i/WLW176i,boiler,8,poolstarts,pool control starts,uint24 (>=0<=16777213), CS6800i/WLW176i,boiler,8,nrgconstotal,total energy consumption,uint24 (>=0<=16777213),kWh,false,sensor.boiler_total_energy_consumption,sensor.boiler_nrgconstotal CS6800i/WLW176i,boiler,8,nrgconscomptotal,total energy consumption compressor,uint24 (>=0<=16777213),kWh,false,sensor.boiler_total_energy_consumption_compressor,sensor.boiler_nrgconscomptotal CS6800i/WLW176i,boiler,8,nrgconscompheating,energy consumption compressor heating,uint24 (>=0<=16777213),kWh,false,sensor.boiler_energy_consumption_compressor_heating,sensor.boiler_nrgconscompheating -CS6800i/WLW176i,boiler,8,nrgconscompdhw,energy consumption compressor,uint24 (>=0<=16777213),kWh,false,sensor.boiler_dhw_energy_consumption_compressor,sensor.boiler_dhw_nrgconscompdhw +CS6800i/WLW176i,boiler,8,nrgconscomp,energy consumption compressor,uint24 (>=0<=16777213),kWh,false,sensor.boiler_dhw_energy_consumption_compressor,sensor.boiler_dhw_nrgconscomp CS6800i/WLW176i,boiler,8,nrgconscompcooling,energy consumption compressor cooling,uint24 (>=0<=16777213),kWh,false,sensor.boiler_energy_consumption_compressor_cooling,sensor.boiler_nrgconscompcooling CS6800i/WLW176i,boiler,8,nrgconscomppool,energy consumption compressor pool,uint24 (>=0<=16777213),kWh,false,sensor.boiler_energy_consumption_compressor_pool,sensor.boiler_nrgconscomppool CS6800i/WLW176i,boiler,8,auxelecheatnrgconstotal,total aux elec. heater energy consumption,uint24 (>=0<=16777213),kWh,false,sensor.boiler_total_aux_elec._heater_energy_consumption,sensor.boiler_auxelecheatnrgconstotal CS6800i/WLW176i,boiler,8,auxelecheatnrgconsheating,aux elec. heater energy consumption heating,uint24 (>=0<=16777213),kWh,false,sensor.boiler_aux_elec._heater_energy_consumption_heating,sensor.boiler_auxelecheatnrgconsheating -CS6800i/WLW176i,boiler,8,auxelecheatnrgconsdhw,aux elec. heater energy consumption,uint24 (>=0<=16777213),kWh,false,sensor.boiler_dhw_aux_elec._heater_energy_consumption,sensor.boiler_dhw_auxelecheatnrgconsdhw +CS6800i/WLW176i,boiler,8,auxelecheatnrgcons,aux elec. heater energy consumption,uint24 (>=0<=16777213),kWh,false,sensor.boiler_dhw_aux_elec._heater_energy_consumption,sensor.boiler_dhw_auxelecheatnrgcons CS6800i/WLW176i,boiler,8,auxelecheatnrgconspool,aux elec. heater energy consumption pool,uint24 (>=0<=16777213),kWh,false,sensor.boiler_aux_elec._heater_energy_consumption_pool,sensor.boiler_auxelecheatnrgconspool CS6800i/WLW176i,boiler,8,nrgsupptotal,total energy supplied,uint24 (>=0<=16777213),kWh,false,sensor.boiler_total_energy_supplied,sensor.boiler_nrgsupptotal CS6800i/WLW176i,boiler,8,nrgsuppheating,total energy supplied heating,uint24 (>=0<=16777213),kWh,false,sensor.boiler_total_energy_supplied_heating,sensor.boiler_nrgsuppheating -CS6800i/WLW176i,boiler,8,nrgsuppdhw,total energy warm supplied,uint24 (>=0<=16777213),kWh,false,sensor.boiler_dhw_total_energy_warm_supplied,sensor.boiler_dhw_nrgsuppdhw +CS6800i/WLW176i,boiler,8,nrgsupp,total energy warm supplied,uint24 (>=0<=16777213),kWh,false,sensor.boiler_dhw_total_energy_warm_supplied,sensor.boiler_dhw_nrgsupp CS6800i/WLW176i,boiler,8,nrgsuppcooling,total energy supplied cooling,uint24 (>=0<=16777213),kWh,false,sensor.boiler_total_energy_supplied_cooling,sensor.boiler_nrgsuppcooling CS6800i/WLW176i,boiler,8,nrgsupppool,total energy supplied pool,uint24 (>=0<=16777213),kWh,false,sensor.boiler_total_energy_supplied_pool,sensor.boiler_nrgsupppool CS6800i/WLW176i,boiler,8,hppower,compressor power output,uint8 (>=0<=25),kW,false,sensor.boiler_compressor_power_output,sensor.boiler_hppower @@ -99,13 +100,17 @@ CS6800i/WLW176i,boiler,8,hpta4,drain pan temp (TA4),int16 (>=-3199<=3199),C,fals CS6800i/WLW176i,boiler,8,hptw1,reservoir temp (TW1),int16 (>=-3199<=3199),C,false,sensor.boiler_reservoir_temp_(TW1),sensor.boiler_hptw1 CS6800i/WLW176i,boiler,8,poolsettemp,pool set temperature,uint8 (>=0<=127),C,true,number.boiler_pool_set_temperature,number.boiler_poolsettemp CS6800i/WLW176i,boiler,8,hp4way,4-way valve (VR4),enum [cooling & defrost\|heating & dhw], ,false,sensor.boiler_4-way_valve_(VR4),sensor.boiler_hp4way +CS6800i/WLW176i,boiler,8,hpin1,input 1 state,boolean, ,false,binary_sensor.boiler_input_1_state,binary_sensor.boiler_hpin1 CS6800i/WLW176i,boiler,8,hpin1opt,input 1 options,string, ,true,sensor.boiler_input_1_options,sensor.boiler_hpin1opt +CS6800i/WLW176i,boiler,8,hpin2,input 2 state,boolean, ,false,binary_sensor.boiler_input_2_state,binary_sensor.boiler_hpin2 CS6800i/WLW176i,boiler,8,hpin2opt,input 2 options,string, ,true,sensor.boiler_input_2_options,sensor.boiler_hpin2opt +CS6800i/WLW176i,boiler,8,hpin3,input 3 state,boolean, ,false,binary_sensor.boiler_input_3_state,binary_sensor.boiler_hpin3 CS6800i/WLW176i,boiler,8,hpin3opt,input 3 options,string, ,true,sensor.boiler_input_3_options,sensor.boiler_hpin3opt +CS6800i/WLW176i,boiler,8,hpin4,input 4 state,boolean, ,false,binary_sensor.boiler_input_4_state,binary_sensor.boiler_hpin4 CS6800i/WLW176i,boiler,8,hpin4opt,input 4 options,string, ,true,sensor.boiler_input_4_options,sensor.boiler_hpin4opt CS6800i/WLW176i,boiler,8,maxheatcomp,heat limit compressor,enum [0 kW\|2 kW\|3 kW\|4 kW\|6 kW\|9 kW], ,true,select.boiler_heat_limit_compressor,select.boiler_maxheatcomp CS6800i/WLW176i,boiler,8,maxheatheat,heat limit heating,enum [0 kW\|2 kW\|3 kW\|4 kW\|6 kW\|9 kW], ,true,select.boiler_heat_limit_heating,select.boiler_maxheatheat -CS6800i/WLW176i,boiler,8,maxheatdhw,heat limit,enum [0 kW\|2 kW\|3 kW\|4 kW\|6 kW\|9 kW], ,true,select.boiler_dhw_heat_limit,select.boiler_dhw_maxheatdhw +CS6800i/WLW176i,boiler,8,maxheat,heat limit,enum [0 kW\|2 kW\|3 kW\|4 kW\|6 kW\|9 kW], ,true,select.boiler_dhw_heat_limit,select.boiler_dhw_maxheat CS6800i/WLW176i,boiler,8,mandefrost,manual defrost,boolean, ,true,switch.boiler_manual_defrost,switch.boiler_mandefrost CS6800i/WLW176i,boiler,8,pvcooling,cooling only with PV,boolean, ,true,switch.boiler_cooling_only_with_PV,switch.boiler_pvcooling CS6800i/WLW176i,boiler,8,auxheateronly,aux heater only,boolean, ,true,switch.boiler_aux_heater_only,switch.boiler_auxheateronly @@ -138,10 +143,10 @@ CS6800i/WLW176i,boiler,8,elheatstep3,el. heater step 3,boolean, ,true,switch.boi CS6800i/WLW176i,boiler,8,hpea0,condensate reservoir heating (EA0),boolean, ,false,binary_sensor.boiler_condensate_reservoir_heating_(EA0),binary_sensor.boiler_hpea0 CS6800i/WLW176i,boiler,8,hppumpmode,primary heatpump mode,enum [auto\|continuous], ,true,select.boiler_primary_heatpump_mode,select.boiler_hppumpmode CS6800i/WLW176i,boiler,8,fan,fan,uint8 (>=20<=100),%,true,number.boiler_fan,number.boiler_fan -CS6800i/WLW176i,boiler,8,shutdown,shutdown,boolean, ,true,switch.boiler_shutdown,switch.boiler_shutdown +CS6800i/WLW176i,boiler,8,shutdown,shutdown,cmd [off\|on], ,true,sensor.boiler_shutdown,sensor.boiler_shutdown CS6800i/WLW176i,boiler,8,alternatingop,alternating operation,boolean, ,true,switch.boiler_dhw_alternating_operation,switch.boiler_dhw_alternatingop CS6800i/WLW176i,boiler,8,altopprioheat,prioritise heating during dhw,uint8 (>=20<=120),minutes,true,number.boiler_dhw_prioritise_heating_during_dhw,number.boiler_dhw_altopprioheat -CS6800i/WLW176i,boiler,8,altoppriodhw,prioritise dhw during heating,uint8 (>=30<=120),minutes,true,number.boiler_dhw_prioritise_dhw_during_heating,number.boiler_dhw_altoppriodhw +CS6800i/WLW176i,boiler,8,altopprio,prioritise dhw during heating,uint8 (>=30<=120),minutes,true,number.boiler_dhw_prioritise_dhw_during_heating,number.boiler_dhw_altopprio CS6800i/WLW176i,boiler,8,comfoff,comfort switch off,uint8 (>=15<=65),C,true,number.boiler_dhw_comfort_switch_off,number.boiler_dhw_comfoff CS6800i/WLW176i,boiler,8,ecooff,eco switch off,uint8 (>=15<=65),C,true,number.boiler_dhw_eco_switch_off,number.boiler_dhw_ecooff CS6800i/WLW176i,boiler,8,ecoplusoff,eco+ switch off,uint8 (>=48<=63),C,true,number.boiler_dhw_eco+_switch_off,number.boiler_dhw_ecoplusoff @@ -151,7 +156,7 @@ CS6800i/WLW176i,boiler,8,ecoplusdiff,eco+ diff,uint8 (>=6<=12),K,true,number.boi CS6800i/WLW176i,boiler,8,comfstop,comfort stop temp,uint8 (>=0<=254),C,true,number.boiler_dhw_comfort_stop_temp,number.boiler_dhw_comfstop CS6800i/WLW176i,boiler,8,ecostop,eco stop temp,uint8 (>=0<=254),C,true,number.boiler_dhw_eco_stop_temp,number.boiler_dhw_ecostop CS6800i/WLW176i,boiler,8,ecoplusstop,eco+ stop temp,uint8 (>=0<=254),C,true,number.boiler_dhw_eco+_stop_temp,number.boiler_dhw_ecoplusstop -CS6800i/WLW176i,boiler,8,hpcircpumpdhw,circulation pump available during dhw,boolean, ,true,switch.boiler_dhw_circulation_pump_available_during_dhw,switch.boiler_dhw_hpcircpumpdhw +CS6800i/WLW176i,boiler,8,hpcircpump,circulation pump available during dhw,boolean, ,true,switch.boiler_dhw_circulation_pump_available_during_dhw,switch.boiler_dhw_hpcircpump CS6800i/WLW176i,boiler,8,tapactivated,turn on/off,boolean, ,true,switch.boiler_dhw_turn_on/off,switch.boiler_dhw_tapactivated CS6800i/WLW176i,boiler,8,settemp,set temperature,uint8 (>=0<=254),C,false,sensor.boiler_dhw_set_temperature,sensor.boiler_dhw_settemp CS6800i/WLW176i,boiler,8,seltemp,selected temperature,uint8 (>=0<=254),C,true,number.boiler_dhw_selected_temperature,number.boiler_dhw_seltemp @@ -224,7 +229,7 @@ C1200W,boiler,12,boil2hystoff,hysteresis stage 2 off temperature,int8 (>=0<=20), C1200W,boiler,12,curveon,heatingcurve on,boolean, ,true,switch.boiler_heatingcurve_on,switch.boiler_curveon C1200W,boiler,12,curvebase,heatingcurve base,uint8 (>=20<=90),C,true,number.boiler_heatingcurve_base,number.boiler_curvebase C1200W,boiler,12,curveend,heatingcurve end,uint8 (>=20<=90),C,true,number.boiler_heatingcurve_end,number.boiler_curveend -C1200W,boiler,12,summertemp,summer temperature,uint8 (>=0<=30),C,true,number.boiler_summer_temperature,number.boiler_summertemp +C1200W,boiler,12,summertemp,summer temperature,uint8 (>=0<=45),C,true,number.boiler_summer_temperature,number.boiler_summertemp C1200W,boiler,12,nofrostmode,nofrost mode,boolean, ,true,switch.boiler_nofrost_mode,switch.boiler_nofrostmode C1200W,boiler,12,nofrosttemp,nofrost temperature,uint8 (>=0<=10),C,true,number.boiler_nofrost_temperature,number.boiler_nofrosttemp C1200W,boiler,12,heatingactivated,heating activated,boolean, ,true,switch.boiler_heating_activated,switch.boiler_heatingactivated @@ -233,6 +238,7 @@ C1200W,boiler,12,heatingpump,heating pump,boolean, ,false,binary_sensor.boiler_h C1200W,boiler,12,pumpmodmax,boiler pump max power,uint8 (>=0<=100),%,true,number.boiler_boiler_pump_max_power,number.boiler_pumpmodmax C1200W,boiler,12,pumpmodmin,boiler pump min power,uint8 (>=0<=100),%,true,number.boiler_boiler_pump_min_power,number.boiler_pumpmodmin C1200W,boiler,12,pumpmode,boiler pump mode,enum [proportional\|deltaP-1\|deltaP-2\|deltaP-3\|deltaP-4], ,true,select.boiler_boiler_pump_mode,select.boiler_pumpmode +C1200W,boiler,12,pumpcharacter,boiler pump characteristic,enum [proportional\|150mbar\|200mbar\|250mbar\|300mbar\|350mbar\|400mbar], ,true,select.boiler_boiler_pump_characteristic,select.boiler_pumpcharacter C1200W,boiler,12,pumpdelay,pump delay,uint8 (>=0<=60),minutes,true,number.boiler_pump_delay,number.boiler_pumpdelay C1200W,boiler,12,setflowtemp,set flow temperature,uint8 (>=0<=254),C,false,sensor.boiler_set_flow_temperature,sensor.boiler_setflowtemp C1200W,boiler,12,setburnpow,burner set power,uint8 (>=0<=100),%,false,sensor.boiler_burner_set_power,sensor.boiler_setburnpow @@ -254,11 +260,11 @@ C1200W,boiler,12,maintenancedate,next maintenance date,string, ,true,sensor.boil C1200W,boiler,12,emergencyops,emergency operation,boolean, ,true,switch.boiler_emergency_operation,switch.boiler_emergencyops C1200W,boiler,12,emergencytemp,emergency temperature,uint8 (>=15<=70),C,true,number.boiler_emergency_temperature,number.boiler_emergencytemp C1200W,boiler,12,meterheat,meter heating,uint24 (>=0<=1677721),kWh,false,sensor.boiler_meter_heating,sensor.boiler_meterheat -C1200W,boiler,12,meterdhw,meter,uint24 (>=0<=1677721),kWh,false,sensor.boiler_dhw_meter,sensor.boiler_dhw_meterdhw +C1200W,boiler,12,meter,meter,uint24 (>=0<=1677721),kWh,false,sensor.boiler_dhw_meter,sensor.boiler_dhw_meter C1200W,boiler,12,gasmeterheat,gas meter heating,uint24 (>=0<=1677721),kWh,false,sensor.boiler_gas_meter_heating,sensor.boiler_gasmeterheat -C1200W,boiler,12,gasmeterdhw,gas meter,uint24 (>=0<=1677721),kWh,false,sensor.boiler_dhw_gas_meter,sensor.boiler_dhw_gasmeterdhw +C1200W,boiler,12,gasmeter,gas meter,uint24 (>=0<=1677721),kWh,false,sensor.boiler_dhw_gas_meter,sensor.boiler_dhw_gasmeter C1200W,boiler,12,nrgheat2,energy heating 2,uint24 (>=0<=1677721),kWh,false,sensor.boiler_energy_heating_2,sensor.boiler_nrgheat2 -C1200W,boiler,12,nrgdhw2,energy 2,uint24 (>=0<=1677721),kWh,false,sensor.boiler_dhw_energy_2,sensor.boiler_dhw_nrgdhw2 +C1200W,boiler,12,nrg2,energy 2,uint24 (>=0<=1677721),kWh,false,sensor.boiler_dhw_energy_2,sensor.boiler_dhw_nrg2 C1200W,boiler,12,tapactivated,turn on/off,boolean, ,true,switch.boiler_dhw_turn_on/off,switch.boiler_dhw_tapactivated C1200W,boiler,12,settemp,set temperature,uint8 (>=0<=254),C,false,sensor.boiler_dhw_set_temperature,sensor.boiler_dhw_settemp C1200W,boiler,12,seltemp,selected temperature,uint8 (>=0<=254),C,true,number.boiler_dhw_selected_temperature,number.boiler_dhw_seltemp @@ -302,7 +308,7 @@ C1200W,boiler,12,workm,active time,time (>=0<=16777213),minutes,false,sensor.boi C1200W,boiler,12,nompower,nominal Power,uint8 (>=0<=254),kW,true,number.boiler_nominal_Power,number.boiler_nompower C1200W,boiler,12,nrgtotal,total energy,uint24 (>=0<=167772),kWh,false,sensor.boiler_total_energy,sensor.boiler_nrgtotal C1200W,boiler,12,nrgheat,energy heating,uint24 (>=0<=10000000),kWh,true,number.boiler_energy_heating,number.boiler_nrgheat -C1200W,boiler,12,nrgdhw,energy,uint24 (>=0<=10000000),kWh,true,number.boiler_dhw_energy,number.boiler_dhw_nrgdhw +C1200W,boiler,12,nrg,energy,uint24 (>=0<=10000000),kWh,true,number.boiler_dhw_energy,number.boiler_dhw_nrg BK13/BK15/Smartline/GB1x2,boiler,64,reset,reset,cmd [-\|maintenance\|error\|history\|message], ,true,sensor.boiler_reset,sensor.boiler_reset BK13/BK15/Smartline/GB1x2,boiler,64,heatingoff,force heating off,boolean, ,true,switch.boiler_force_heating_off,switch.boiler_heatingoff BK13/BK15/Smartline/GB1x2,boiler,64,heatingactive,heating active,boolean, ,false,binary_sensor.boiler_heating_active,binary_sensor.boiler_heatingactive @@ -335,7 +341,7 @@ BK13/BK15/Smartline/GB1x2,boiler,64,boil2hystoff,hysteresis stage 2 off temperat BK13/BK15/Smartline/GB1x2,boiler,64,curveon,heatingcurve on,boolean, ,true,switch.boiler_heatingcurve_on,switch.boiler_curveon BK13/BK15/Smartline/GB1x2,boiler,64,curvebase,heatingcurve base,uint8 (>=20<=90),C,true,number.boiler_heatingcurve_base,number.boiler_curvebase BK13/BK15/Smartline/GB1x2,boiler,64,curveend,heatingcurve end,uint8 (>=20<=90),C,true,number.boiler_heatingcurve_end,number.boiler_curveend -BK13/BK15/Smartline/GB1x2,boiler,64,summertemp,summer temperature,uint8 (>=0<=30),C,true,number.boiler_summer_temperature,number.boiler_summertemp +BK13/BK15/Smartline/GB1x2,boiler,64,summertemp,summer temperature,uint8 (>=0<=45),C,true,number.boiler_summer_temperature,number.boiler_summertemp BK13/BK15/Smartline/GB1x2,boiler,64,nofrostmode,nofrost mode,boolean, ,true,switch.boiler_nofrost_mode,switch.boiler_nofrostmode BK13/BK15/Smartline/GB1x2,boiler,64,nofrosttemp,nofrost temperature,uint8 (>=0<=10),C,true,number.boiler_nofrost_temperature,number.boiler_nofrosttemp BK13/BK15/Smartline/GB1x2,boiler,64,heatingactivated,heating activated,boolean, ,true,switch.boiler_heating_activated,switch.boiler_heatingactivated @@ -344,6 +350,7 @@ BK13/BK15/Smartline/GB1x2,boiler,64,heatingpump,heating pump,boolean, ,false,bin BK13/BK15/Smartline/GB1x2,boiler,64,pumpmodmax,boiler pump max power,uint8 (>=0<=100),%,true,number.boiler_boiler_pump_max_power,number.boiler_pumpmodmax BK13/BK15/Smartline/GB1x2,boiler,64,pumpmodmin,boiler pump min power,uint8 (>=0<=100),%,true,number.boiler_boiler_pump_min_power,number.boiler_pumpmodmin BK13/BK15/Smartline/GB1x2,boiler,64,pumpmode,boiler pump mode,enum [proportional\|deltaP-1\|deltaP-2\|deltaP-3\|deltaP-4], ,true,select.boiler_boiler_pump_mode,select.boiler_pumpmode +BK13/BK15/Smartline/GB1x2,boiler,64,pumpcharacter,boiler pump characteristic,enum [proportional\|150mbar\|200mbar\|250mbar\|300mbar\|350mbar\|400mbar], ,true,select.boiler_boiler_pump_characteristic,select.boiler_pumpcharacter BK13/BK15/Smartline/GB1x2,boiler,64,pumpdelay,pump delay,uint8 (>=0<=60),minutes,true,number.boiler_pump_delay,number.boiler_pumpdelay BK13/BK15/Smartline/GB1x2,boiler,64,setflowtemp,set flow temperature,uint8 (>=0<=254),C,false,sensor.boiler_set_flow_temperature,sensor.boiler_setflowtemp BK13/BK15/Smartline/GB1x2,boiler,64,setburnpow,burner set power,uint8 (>=0<=100),%,false,sensor.boiler_burner_set_power,sensor.boiler_setburnpow @@ -365,11 +372,11 @@ BK13/BK15/Smartline/GB1x2,boiler,64,maintenancedate,next maintenance date,string BK13/BK15/Smartline/GB1x2,boiler,64,emergencyops,emergency operation,boolean, ,true,switch.boiler_emergency_operation,switch.boiler_emergencyops BK13/BK15/Smartline/GB1x2,boiler,64,emergencytemp,emergency temperature,uint8 (>=15<=70),C,true,number.boiler_emergency_temperature,number.boiler_emergencytemp BK13/BK15/Smartline/GB1x2,boiler,64,meterheat,meter heating,uint24 (>=0<=1677721),kWh,false,sensor.boiler_meter_heating,sensor.boiler_meterheat -BK13/BK15/Smartline/GB1x2,boiler,64,meterdhw,meter,uint24 (>=0<=1677721),kWh,false,sensor.boiler_dhw_meter,sensor.boiler_dhw_meterdhw +BK13/BK15/Smartline/GB1x2,boiler,64,meter,meter,uint24 (>=0<=1677721),kWh,false,sensor.boiler_dhw_meter,sensor.boiler_dhw_meter BK13/BK15/Smartline/GB1x2,boiler,64,gasmeterheat,gas meter heating,uint24 (>=0<=1677721),kWh,false,sensor.boiler_gas_meter_heating,sensor.boiler_gasmeterheat -BK13/BK15/Smartline/GB1x2,boiler,64,gasmeterdhw,gas meter,uint24 (>=0<=1677721),kWh,false,sensor.boiler_dhw_gas_meter,sensor.boiler_dhw_gasmeterdhw +BK13/BK15/Smartline/GB1x2,boiler,64,gasmeter,gas meter,uint24 (>=0<=1677721),kWh,false,sensor.boiler_dhw_gas_meter,sensor.boiler_dhw_gasmeter BK13/BK15/Smartline/GB1x2,boiler,64,nrgheat2,energy heating 2,uint24 (>=0<=1677721),kWh,false,sensor.boiler_energy_heating_2,sensor.boiler_nrgheat2 -BK13/BK15/Smartline/GB1x2,boiler,64,nrgdhw2,energy 2,uint24 (>=0<=1677721),kWh,false,sensor.boiler_dhw_energy_2,sensor.boiler_dhw_nrgdhw2 +BK13/BK15/Smartline/GB1x2,boiler,64,nrg2,energy 2,uint24 (>=0<=1677721),kWh,false,sensor.boiler_dhw_energy_2,sensor.boiler_dhw_nrg2 BK13/BK15/Smartline/GB1x2,boiler,64,tapactivated,turn on/off,boolean, ,true,switch.boiler_dhw_turn_on/off,switch.boiler_dhw_tapactivated BK13/BK15/Smartline/GB1x2,boiler,64,settemp,set temperature,uint8 (>=0<=254),C,false,sensor.boiler_dhw_set_temperature,sensor.boiler_dhw_settemp BK13/BK15/Smartline/GB1x2,boiler,64,seltemp,selected temperature,uint8 (>=0<=254),C,true,number.boiler_dhw_selected_temperature,number.boiler_dhw_seltemp @@ -413,7 +420,7 @@ BK13/BK15/Smartline/GB1x2,boiler,64,workm,active time,time (>=0<=16777213),minut BK13/BK15/Smartline/GB1x2,boiler,64,nompower,nominal Power,uint8 (>=0<=254),kW,true,number.boiler_nominal_Power,number.boiler_nompower BK13/BK15/Smartline/GB1x2,boiler,64,nrgtotal,total energy,uint24 (>=0<=167772),kWh,false,sensor.boiler_total_energy,sensor.boiler_nrgtotal BK13/BK15/Smartline/GB1x2,boiler,64,nrgheat,energy heating,uint24 (>=0<=10000000),kWh,true,number.boiler_energy_heating,number.boiler_nrgheat -BK13/BK15/Smartline/GB1x2,boiler,64,nrgdhw,energy,uint24 (>=0<=10000000),kWh,true,number.boiler_dhw_energy,number.boiler_dhw_nrgdhw +BK13/BK15/Smartline/GB1x2,boiler,64,nrg,energy,uint24 (>=0<=10000000),kWh,true,number.boiler_dhw_energy,number.boiler_dhw_nrg GB125/GB135/MC10,boiler,72,reset,reset,cmd [-\|maintenance\|error\|history\|message], ,true,sensor.boiler_reset,sensor.boiler_reset GB125/GB135/MC10,boiler,72,heatingoff,force heating off,boolean, ,true,switch.boiler_force_heating_off,switch.boiler_heatingoff GB125/GB135/MC10,boiler,72,heatingactive,heating active,boolean, ,false,binary_sensor.boiler_heating_active,binary_sensor.boiler_heatingactive @@ -446,7 +453,7 @@ GB125/GB135/MC10,boiler,72,boil2hystoff,hysteresis stage 2 off temperature,int8 GB125/GB135/MC10,boiler,72,curveon,heatingcurve on,boolean, ,true,switch.boiler_heatingcurve_on,switch.boiler_curveon GB125/GB135/MC10,boiler,72,curvebase,heatingcurve base,uint8 (>=20<=90),C,true,number.boiler_heatingcurve_base,number.boiler_curvebase GB125/GB135/MC10,boiler,72,curveend,heatingcurve end,uint8 (>=20<=90),C,true,number.boiler_heatingcurve_end,number.boiler_curveend -GB125/GB135/MC10,boiler,72,summertemp,summer temperature,uint8 (>=0<=30),C,true,number.boiler_summer_temperature,number.boiler_summertemp +GB125/GB135/MC10,boiler,72,summertemp,summer temperature,uint8 (>=0<=45),C,true,number.boiler_summer_temperature,number.boiler_summertemp GB125/GB135/MC10,boiler,72,nofrostmode,nofrost mode,boolean, ,true,switch.boiler_nofrost_mode,switch.boiler_nofrostmode GB125/GB135/MC10,boiler,72,nofrosttemp,nofrost temperature,uint8 (>=0<=10),C,true,number.boiler_nofrost_temperature,number.boiler_nofrosttemp GB125/GB135/MC10,boiler,72,heatingactivated,heating activated,boolean, ,true,switch.boiler_heating_activated,switch.boiler_heatingactivated @@ -455,6 +462,7 @@ GB125/GB135/MC10,boiler,72,heatingpump,heating pump,boolean, ,false,binary_senso GB125/GB135/MC10,boiler,72,pumpmodmax,boiler pump max power,uint8 (>=0<=100),%,true,number.boiler_boiler_pump_max_power,number.boiler_pumpmodmax GB125/GB135/MC10,boiler,72,pumpmodmin,boiler pump min power,uint8 (>=0<=100),%,true,number.boiler_boiler_pump_min_power,number.boiler_pumpmodmin GB125/GB135/MC10,boiler,72,pumpmode,boiler pump mode,enum [proportional\|deltaP-1\|deltaP-2\|deltaP-3\|deltaP-4], ,true,select.boiler_boiler_pump_mode,select.boiler_pumpmode +GB125/GB135/MC10,boiler,72,pumpcharacter,boiler pump characteristic,enum [proportional\|150mbar\|200mbar\|250mbar\|300mbar\|350mbar\|400mbar], ,true,select.boiler_boiler_pump_characteristic,select.boiler_pumpcharacter GB125/GB135/MC10,boiler,72,pumpdelay,pump delay,uint8 (>=0<=60),minutes,true,number.boiler_pump_delay,number.boiler_pumpdelay GB125/GB135/MC10,boiler,72,setflowtemp,set flow temperature,uint8 (>=0<=254),C,false,sensor.boiler_set_flow_temperature,sensor.boiler_setflowtemp GB125/GB135/MC10,boiler,72,setburnpow,burner set power,uint8 (>=0<=100),%,false,sensor.boiler_burner_set_power,sensor.boiler_setburnpow @@ -476,11 +484,11 @@ GB125/GB135/MC10,boiler,72,maintenancedate,next maintenance date,string, ,true,s GB125/GB135/MC10,boiler,72,emergencyops,emergency operation,boolean, ,true,switch.boiler_emergency_operation,switch.boiler_emergencyops GB125/GB135/MC10,boiler,72,emergencytemp,emergency temperature,uint8 (>=15<=70),C,true,number.boiler_emergency_temperature,number.boiler_emergencytemp GB125/GB135/MC10,boiler,72,meterheat,meter heating,uint24 (>=0<=1677721),kWh,false,sensor.boiler_meter_heating,sensor.boiler_meterheat -GB125/GB135/MC10,boiler,72,meterdhw,meter,uint24 (>=0<=1677721),kWh,false,sensor.boiler_dhw_meter,sensor.boiler_dhw_meterdhw +GB125/GB135/MC10,boiler,72,meter,meter,uint24 (>=0<=1677721),kWh,false,sensor.boiler_dhw_meter,sensor.boiler_dhw_meter GB125/GB135/MC10,boiler,72,gasmeterheat,gas meter heating,uint24 (>=0<=1677721),kWh,false,sensor.boiler_gas_meter_heating,sensor.boiler_gasmeterheat -GB125/GB135/MC10,boiler,72,gasmeterdhw,gas meter,uint24 (>=0<=1677721),kWh,false,sensor.boiler_dhw_gas_meter,sensor.boiler_dhw_gasmeterdhw +GB125/GB135/MC10,boiler,72,gasmeter,gas meter,uint24 (>=0<=1677721),kWh,false,sensor.boiler_dhw_gas_meter,sensor.boiler_dhw_gasmeter GB125/GB135/MC10,boiler,72,nrgheat2,energy heating 2,uint24 (>=0<=1677721),kWh,false,sensor.boiler_energy_heating_2,sensor.boiler_nrgheat2 -GB125/GB135/MC10,boiler,72,nrgdhw2,energy 2,uint24 (>=0<=1677721),kWh,false,sensor.boiler_dhw_energy_2,sensor.boiler_dhw_nrgdhw2 +GB125/GB135/MC10,boiler,72,nrg2,energy 2,uint24 (>=0<=1677721),kWh,false,sensor.boiler_dhw_energy_2,sensor.boiler_dhw_nrg2 GB125/GB135/MC10,boiler,72,tapactivated,turn on/off,boolean, ,true,switch.boiler_dhw_turn_on/off,switch.boiler_dhw_tapactivated GB125/GB135/MC10,boiler,72,settemp,set temperature,uint8 (>=0<=254),C,false,sensor.boiler_dhw_set_temperature,sensor.boiler_dhw_settemp GB125/GB135/MC10,boiler,72,seltemp,selected temperature,uint8 (>=0<=254),C,true,number.boiler_dhw_selected_temperature,number.boiler_dhw_seltemp @@ -524,7 +532,7 @@ GB125/GB135/MC10,boiler,72,workm,active time,time (>=0<=16777213),minutes,false, GB125/GB135/MC10,boiler,72,nompower,nominal Power,uint8 (>=0<=254),kW,true,number.boiler_nominal_Power,number.boiler_nompower GB125/GB135/MC10,boiler,72,nrgtotal,total energy,uint24 (>=0<=167772),kWh,false,sensor.boiler_total_energy,sensor.boiler_nrgtotal GB125/GB135/MC10,boiler,72,nrgheat,energy heating,uint24 (>=0<=10000000),kWh,true,number.boiler_energy_heating,number.boiler_nrgheat -GB125/GB135/MC10,boiler,72,nrgdhw,energy,uint24 (>=0<=10000000),kWh,true,number.boiler_dhw_energy,number.boiler_dhw_nrgdhw +GB125/GB135/MC10,boiler,72,nrg,energy,uint24 (>=0<=10000000),kWh,true,number.boiler_dhw_energy,number.boiler_dhw_nrg Cascade CM10,boiler,81,reset,reset,cmd [-\|maintenance\|error\|history\|message], ,true,sensor.boiler_reset,sensor.boiler_reset Cascade CM10,boiler,81,heatingoff,force heating off,boolean, ,true,switch.boiler_force_heating_off,switch.boiler_heatingoff Cascade CM10,boiler,81,heatingactive,heating active,boolean, ,false,binary_sensor.boiler_heating_active,binary_sensor.boiler_heatingactive @@ -557,7 +565,7 @@ Cascade CM10,boiler,81,boil2hystoff,hysteresis stage 2 off temperature,int8 (>=0 Cascade CM10,boiler,81,curveon,heatingcurve on,boolean, ,true,switch.boiler_heatingcurve_on,switch.boiler_curveon Cascade CM10,boiler,81,curvebase,heatingcurve base,uint8 (>=20<=90),C,true,number.boiler_heatingcurve_base,number.boiler_curvebase Cascade CM10,boiler,81,curveend,heatingcurve end,uint8 (>=20<=90),C,true,number.boiler_heatingcurve_end,number.boiler_curveend -Cascade CM10,boiler,81,summertemp,summer temperature,uint8 (>=0<=30),C,true,number.boiler_summer_temperature,number.boiler_summertemp +Cascade CM10,boiler,81,summertemp,summer temperature,uint8 (>=0<=45),C,true,number.boiler_summer_temperature,number.boiler_summertemp Cascade CM10,boiler,81,nofrostmode,nofrost mode,boolean, ,true,switch.boiler_nofrost_mode,switch.boiler_nofrostmode Cascade CM10,boiler,81,nofrosttemp,nofrost temperature,uint8 (>=0<=10),C,true,number.boiler_nofrost_temperature,number.boiler_nofrosttemp Cascade CM10,boiler,81,heatingactivated,heating activated,boolean, ,true,switch.boiler_heating_activated,switch.boiler_heatingactivated @@ -566,6 +574,7 @@ Cascade CM10,boiler,81,heatingpump,heating pump,boolean, ,false,binary_sensor.bo Cascade CM10,boiler,81,pumpmodmax,boiler pump max power,uint8 (>=0<=100),%,true,number.boiler_boiler_pump_max_power,number.boiler_pumpmodmax Cascade CM10,boiler,81,pumpmodmin,boiler pump min power,uint8 (>=0<=100),%,true,number.boiler_boiler_pump_min_power,number.boiler_pumpmodmin Cascade CM10,boiler,81,pumpmode,boiler pump mode,enum [proportional\|deltaP-1\|deltaP-2\|deltaP-3\|deltaP-4], ,true,select.boiler_boiler_pump_mode,select.boiler_pumpmode +Cascade CM10,boiler,81,pumpcharacter,boiler pump characteristic,enum [proportional\|150mbar\|200mbar\|250mbar\|300mbar\|350mbar\|400mbar], ,true,select.boiler_boiler_pump_characteristic,select.boiler_pumpcharacter Cascade CM10,boiler,81,pumpdelay,pump delay,uint8 (>=0<=60),minutes,true,number.boiler_pump_delay,number.boiler_pumpdelay Cascade CM10,boiler,81,setflowtemp,set flow temperature,uint8 (>=0<=254),C,false,sensor.boiler_set_flow_temperature,sensor.boiler_setflowtemp Cascade CM10,boiler,81,setburnpow,burner set power,uint8 (>=0<=100),%,false,sensor.boiler_burner_set_power,sensor.boiler_setburnpow @@ -587,11 +596,11 @@ Cascade CM10,boiler,81,maintenancedate,next maintenance date,string, ,true,senso Cascade CM10,boiler,81,emergencyops,emergency operation,boolean, ,true,switch.boiler_emergency_operation,switch.boiler_emergencyops Cascade CM10,boiler,81,emergencytemp,emergency temperature,uint8 (>=15<=70),C,true,number.boiler_emergency_temperature,number.boiler_emergencytemp Cascade CM10,boiler,81,meterheat,meter heating,uint24 (>=0<=1677721),kWh,false,sensor.boiler_meter_heating,sensor.boiler_meterheat -Cascade CM10,boiler,81,meterdhw,meter,uint24 (>=0<=1677721),kWh,false,sensor.boiler_dhw_meter,sensor.boiler_dhw_meterdhw +Cascade CM10,boiler,81,meter,meter,uint24 (>=0<=1677721),kWh,false,sensor.boiler_dhw_meter,sensor.boiler_dhw_meter Cascade CM10,boiler,81,gasmeterheat,gas meter heating,uint24 (>=0<=1677721),kWh,false,sensor.boiler_gas_meter_heating,sensor.boiler_gasmeterheat -Cascade CM10,boiler,81,gasmeterdhw,gas meter,uint24 (>=0<=1677721),kWh,false,sensor.boiler_dhw_gas_meter,sensor.boiler_dhw_gasmeterdhw +Cascade CM10,boiler,81,gasmeter,gas meter,uint24 (>=0<=1677721),kWh,false,sensor.boiler_dhw_gas_meter,sensor.boiler_dhw_gasmeter Cascade CM10,boiler,81,nrgheat2,energy heating 2,uint24 (>=0<=1677721),kWh,false,sensor.boiler_energy_heating_2,sensor.boiler_nrgheat2 -Cascade CM10,boiler,81,nrgdhw2,energy 2,uint24 (>=0<=1677721),kWh,false,sensor.boiler_dhw_energy_2,sensor.boiler_dhw_nrgdhw2 +Cascade CM10,boiler,81,nrg2,energy 2,uint24 (>=0<=1677721),kWh,false,sensor.boiler_dhw_energy_2,sensor.boiler_dhw_nrg2 Cascade CM10,boiler,81,tapactivated,turn on/off,boolean, ,true,switch.boiler_dhw_turn_on/off,switch.boiler_dhw_tapactivated Cascade CM10,boiler,81,settemp,set temperature,uint8 (>=0<=254),C,false,sensor.boiler_dhw_set_temperature,sensor.boiler_dhw_settemp Cascade CM10,boiler,81,seltemp,selected temperature,uint8 (>=0<=254),C,true,number.boiler_dhw_selected_temperature,number.boiler_dhw_seltemp @@ -635,7 +644,7 @@ Cascade CM10,boiler,81,workm,active time,time (>=0<=16777213),minutes,false,sens Cascade CM10,boiler,81,nompower,nominal Power,uint8 (>=0<=254),kW,true,number.boiler_nominal_Power,number.boiler_nompower Cascade CM10,boiler,81,nrgtotal,total energy,uint24 (>=0<=167772),kWh,false,sensor.boiler_total_energy,sensor.boiler_nrgtotal Cascade CM10,boiler,81,nrgheat,energy heating,uint24 (>=0<=10000000),kWh,true,number.boiler_energy_heating,number.boiler_nrgheat -Cascade CM10,boiler,81,nrgdhw,energy,uint24 (>=0<=10000000),kWh,true,number.boiler_dhw_energy,number.boiler_dhw_nrgdhw +Cascade CM10,boiler,81,nrg,energy,uint24 (>=0<=10000000),kWh,true,number.boiler_dhw_energy,number.boiler_dhw_nrg Logamax Plus GB022,boiler,84,reset,reset,cmd [-\|maintenance\|error\|history\|message], ,true,sensor.boiler_reset,sensor.boiler_reset Logamax Plus GB022,boiler,84,heatingoff,force heating off,boolean, ,true,switch.boiler_force_heating_off,switch.boiler_heatingoff Logamax Plus GB022,boiler,84,heatingactive,heating active,boolean, ,false,binary_sensor.boiler_heating_active,binary_sensor.boiler_heatingactive @@ -668,7 +677,7 @@ Logamax Plus GB022,boiler,84,boil2hystoff,hysteresis stage 2 off temperature,int Logamax Plus GB022,boiler,84,curveon,heatingcurve on,boolean, ,true,switch.boiler_heatingcurve_on,switch.boiler_curveon Logamax Plus GB022,boiler,84,curvebase,heatingcurve base,uint8 (>=20<=90),C,true,number.boiler_heatingcurve_base,number.boiler_curvebase Logamax Plus GB022,boiler,84,curveend,heatingcurve end,uint8 (>=20<=90),C,true,number.boiler_heatingcurve_end,number.boiler_curveend -Logamax Plus GB022,boiler,84,summertemp,summer temperature,uint8 (>=0<=30),C,true,number.boiler_summer_temperature,number.boiler_summertemp +Logamax Plus GB022,boiler,84,summertemp,summer temperature,uint8 (>=0<=45),C,true,number.boiler_summer_temperature,number.boiler_summertemp Logamax Plus GB022,boiler,84,nofrostmode,nofrost mode,boolean, ,true,switch.boiler_nofrost_mode,switch.boiler_nofrostmode Logamax Plus GB022,boiler,84,nofrosttemp,nofrost temperature,uint8 (>=0<=10),C,true,number.boiler_nofrost_temperature,number.boiler_nofrosttemp Logamax Plus GB022,boiler,84,heatingactivated,heating activated,boolean, ,true,switch.boiler_heating_activated,switch.boiler_heatingactivated @@ -677,6 +686,7 @@ Logamax Plus GB022,boiler,84,heatingpump,heating pump,boolean, ,false,binary_sen Logamax Plus GB022,boiler,84,pumpmodmax,boiler pump max power,uint8 (>=0<=100),%,true,number.boiler_boiler_pump_max_power,number.boiler_pumpmodmax Logamax Plus GB022,boiler,84,pumpmodmin,boiler pump min power,uint8 (>=0<=100),%,true,number.boiler_boiler_pump_min_power,number.boiler_pumpmodmin Logamax Plus GB022,boiler,84,pumpmode,boiler pump mode,enum [proportional\|deltaP-1\|deltaP-2\|deltaP-3\|deltaP-4], ,true,select.boiler_boiler_pump_mode,select.boiler_pumpmode +Logamax Plus GB022,boiler,84,pumpcharacter,boiler pump characteristic,enum [proportional\|150mbar\|200mbar\|250mbar\|300mbar\|350mbar\|400mbar], ,true,select.boiler_boiler_pump_characteristic,select.boiler_pumpcharacter Logamax Plus GB022,boiler,84,pumpdelay,pump delay,uint8 (>=0<=60),minutes,true,number.boiler_pump_delay,number.boiler_pumpdelay Logamax Plus GB022,boiler,84,setflowtemp,set flow temperature,uint8 (>=0<=254),C,false,sensor.boiler_set_flow_temperature,sensor.boiler_setflowtemp Logamax Plus GB022,boiler,84,setburnpow,burner set power,uint8 (>=0<=100),%,false,sensor.boiler_burner_set_power,sensor.boiler_setburnpow @@ -698,11 +708,11 @@ Logamax Plus GB022,boiler,84,maintenancedate,next maintenance date,string, ,true Logamax Plus GB022,boiler,84,emergencyops,emergency operation,boolean, ,true,switch.boiler_emergency_operation,switch.boiler_emergencyops Logamax Plus GB022,boiler,84,emergencytemp,emergency temperature,uint8 (>=15<=70),C,true,number.boiler_emergency_temperature,number.boiler_emergencytemp Logamax Plus GB022,boiler,84,meterheat,meter heating,uint24 (>=0<=1677721),kWh,false,sensor.boiler_meter_heating,sensor.boiler_meterheat -Logamax Plus GB022,boiler,84,meterdhw,meter,uint24 (>=0<=1677721),kWh,false,sensor.boiler_dhw_meter,sensor.boiler_dhw_meterdhw +Logamax Plus GB022,boiler,84,meter,meter,uint24 (>=0<=1677721),kWh,false,sensor.boiler_dhw_meter,sensor.boiler_dhw_meter Logamax Plus GB022,boiler,84,gasmeterheat,gas meter heating,uint24 (>=0<=1677721),kWh,false,sensor.boiler_gas_meter_heating,sensor.boiler_gasmeterheat -Logamax Plus GB022,boiler,84,gasmeterdhw,gas meter,uint24 (>=0<=1677721),kWh,false,sensor.boiler_dhw_gas_meter,sensor.boiler_dhw_gasmeterdhw +Logamax Plus GB022,boiler,84,gasmeter,gas meter,uint24 (>=0<=1677721),kWh,false,sensor.boiler_dhw_gas_meter,sensor.boiler_dhw_gasmeter Logamax Plus GB022,boiler,84,nrgheat2,energy heating 2,uint24 (>=0<=1677721),kWh,false,sensor.boiler_energy_heating_2,sensor.boiler_nrgheat2 -Logamax Plus GB022,boiler,84,nrgdhw2,energy 2,uint24 (>=0<=1677721),kWh,false,sensor.boiler_dhw_energy_2,sensor.boiler_dhw_nrgdhw2 +Logamax Plus GB022,boiler,84,nrg2,energy 2,uint24 (>=0<=1677721),kWh,false,sensor.boiler_dhw_energy_2,sensor.boiler_dhw_nrg2 Logamax Plus GB022,boiler,84,tapactivated,turn on/off,boolean, ,true,switch.boiler_dhw_turn_on/off,switch.boiler_dhw_tapactivated Logamax Plus GB022,boiler,84,settemp,set temperature,uint8 (>=0<=254),C,false,sensor.boiler_dhw_set_temperature,sensor.boiler_dhw_settemp Logamax Plus GB022,boiler,84,seltemp,selected temperature,uint8 (>=0<=254),C,true,number.boiler_dhw_selected_temperature,number.boiler_dhw_seltemp @@ -746,7 +756,7 @@ Logamax Plus GB022,boiler,84,workm,active time,time (>=0<=16777213),minutes,fals Logamax Plus GB022,boiler,84,nompower,nominal Power,uint8 (>=0<=254),kW,true,number.boiler_nominal_Power,number.boiler_nompower Logamax Plus GB022,boiler,84,nrgtotal,total energy,uint24 (>=0<=167772),kWh,false,sensor.boiler_total_energy,sensor.boiler_nrgtotal Logamax Plus GB022,boiler,84,nrgheat,energy heating,uint24 (>=0<=10000000),kWh,true,number.boiler_energy_heating,number.boiler_nrgheat -Logamax Plus GB022,boiler,84,nrgdhw,energy,uint24 (>=0<=10000000),kWh,true,number.boiler_dhw_energy,number.boiler_dhw_nrgdhw +Logamax Plus GB022,boiler,84,nrg,energy,uint24 (>=0<=10000000),kWh,true,number.boiler_dhw_energy,number.boiler_dhw_nrg Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,reset,reset,cmd [-\|maintenance\|error\|history\|message], ,true,sensor.boiler_reset,sensor.boiler_reset Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,heatingoff,force heating off,boolean, ,true,switch.boiler_force_heating_off,switch.boiler_heatingoff Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,heatingactive,heating active,boolean, ,false,binary_sensor.boiler_heating_active,binary_sensor.boiler_heatingactive @@ -779,7 +789,7 @@ Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,boil2 Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,curveon,heatingcurve on,boolean, ,true,switch.boiler_heatingcurve_on,switch.boiler_curveon Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,curvebase,heatingcurve base,uint8 (>=20<=90),C,true,number.boiler_heatingcurve_base,number.boiler_curvebase Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,curveend,heatingcurve end,uint8 (>=20<=90),C,true,number.boiler_heatingcurve_end,number.boiler_curveend -Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,summertemp,summer temperature,uint8 (>=0<=30),C,true,number.boiler_summer_temperature,number.boiler_summertemp +Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,summertemp,summer temperature,uint8 (>=0<=45),C,true,number.boiler_summer_temperature,number.boiler_summertemp Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,nofrostmode,nofrost mode,boolean, ,true,switch.boiler_nofrost_mode,switch.boiler_nofrostmode Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,nofrosttemp,nofrost temperature,uint8 (>=0<=10),C,true,number.boiler_nofrost_temperature,number.boiler_nofrosttemp Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,heatingactivated,heating activated,boolean, ,true,switch.boiler_heating_activated,switch.boiler_heatingactivated @@ -788,6 +798,7 @@ Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,heati Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,pumpmodmax,boiler pump max power,uint8 (>=0<=100),%,true,number.boiler_boiler_pump_max_power,number.boiler_pumpmodmax Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,pumpmodmin,boiler pump min power,uint8 (>=0<=100),%,true,number.boiler_boiler_pump_min_power,number.boiler_pumpmodmin Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,pumpmode,boiler pump mode,enum [proportional\|deltaP-1\|deltaP-2\|deltaP-3\|deltaP-4], ,true,select.boiler_boiler_pump_mode,select.boiler_pumpmode +Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,pumpcharacter,boiler pump characteristic,enum [proportional\|150mbar\|200mbar\|250mbar\|300mbar\|350mbar\|400mbar], ,true,select.boiler_boiler_pump_characteristic,select.boiler_pumpcharacter Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,pumpdelay,pump delay,uint8 (>=0<=60),minutes,true,number.boiler_pump_delay,number.boiler_pumpdelay Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,setflowtemp,set flow temperature,uint8 (>=0<=254),C,false,sensor.boiler_set_flow_temperature,sensor.boiler_setflowtemp Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,setburnpow,burner set power,uint8 (>=0<=100),%,false,sensor.boiler_burner_set_power,sensor.boiler_setburnpow @@ -809,11 +820,11 @@ Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,maint Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,emergencyops,emergency operation,boolean, ,true,switch.boiler_emergency_operation,switch.boiler_emergencyops Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,emergencytemp,emergency temperature,uint8 (>=15<=70),C,true,number.boiler_emergency_temperature,number.boiler_emergencytemp Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,meterheat,meter heating,uint24 (>=0<=1677721),kWh,false,sensor.boiler_meter_heating,sensor.boiler_meterheat -Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,meterdhw,meter,uint24 (>=0<=1677721),kWh,false,sensor.boiler_dhw_meter,sensor.boiler_dhw_meterdhw +Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,meter,meter,uint24 (>=0<=1677721),kWh,false,sensor.boiler_dhw_meter,sensor.boiler_dhw_meter Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,gasmeterheat,gas meter heating,uint24 (>=0<=1677721),kWh,false,sensor.boiler_gas_meter_heating,sensor.boiler_gasmeterheat -Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,gasmeterdhw,gas meter,uint24 (>=0<=1677721),kWh,false,sensor.boiler_dhw_gas_meter,sensor.boiler_dhw_gasmeterdhw +Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,gasmeter,gas meter,uint24 (>=0<=1677721),kWh,false,sensor.boiler_dhw_gas_meter,sensor.boiler_dhw_gasmeter Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,nrgheat2,energy heating 2,uint24 (>=0<=1677721),kWh,false,sensor.boiler_energy_heating_2,sensor.boiler_nrgheat2 -Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,nrgdhw2,energy 2,uint24 (>=0<=1677721),kWh,false,sensor.boiler_dhw_energy_2,sensor.boiler_dhw_nrgdhw2 +Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,nrg2,energy 2,uint24 (>=0<=1677721),kWh,false,sensor.boiler_dhw_energy_2,sensor.boiler_dhw_nrg2 Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,tapactivated,turn on/off,boolean, ,true,switch.boiler_dhw_turn_on/off,switch.boiler_dhw_tapactivated Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,settemp,set temperature,uint8 (>=0<=254),C,false,sensor.boiler_dhw_set_temperature,sensor.boiler_dhw_settemp Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,seltemp,selected temperature,uint8 (>=0<=254),C,true,number.boiler_dhw_selected_temperature,number.boiler_dhw_seltemp @@ -857,7 +868,7 @@ Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,workm Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,nompower,nominal Power,uint8 (>=0<=254),kW,true,number.boiler_nominal_Power,number.boiler_nompower Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,nrgtotal,total energy,uint24 (>=0<=167772),kWh,false,sensor.boiler_total_energy,sensor.boiler_nrgtotal Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,nrgheat,energy heating,uint24 (>=0<=10000000),kWh,true,number.boiler_energy_heating,number.boiler_nrgheat -Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,nrgdhw,energy,uint24 (>=0<=10000000),kWh,true,number.boiler_dhw_energy,number.boiler_dhw_nrgdhw +Condens 2500/Logamax/Logomatic/Cerapur Top/Greenstar/Generic HT3,boiler,95,nrg,energy,uint24 (>=0<=10000000),kWh,true,number.boiler_dhw_energy,number.boiler_dhw_nrg Topline/GB162,boiler,115,reset,reset,cmd [-\|maintenance\|error\|history\|message], ,true,sensor.boiler_reset,sensor.boiler_reset Topline/GB162,boiler,115,heatingoff,force heating off,boolean, ,true,switch.boiler_force_heating_off,switch.boiler_heatingoff Topline/GB162,boiler,115,heatingactive,heating active,boolean, ,false,binary_sensor.boiler_heating_active,binary_sensor.boiler_heatingactive @@ -890,7 +901,7 @@ Topline/GB162,boiler,115,boil2hystoff,hysteresis stage 2 off temperature,int8 (> Topline/GB162,boiler,115,curveon,heatingcurve on,boolean, ,true,switch.boiler_heatingcurve_on,switch.boiler_curveon Topline/GB162,boiler,115,curvebase,heatingcurve base,uint8 (>=20<=90),C,true,number.boiler_heatingcurve_base,number.boiler_curvebase Topline/GB162,boiler,115,curveend,heatingcurve end,uint8 (>=20<=90),C,true,number.boiler_heatingcurve_end,number.boiler_curveend -Topline/GB162,boiler,115,summertemp,summer temperature,uint8 (>=0<=30),C,true,number.boiler_summer_temperature,number.boiler_summertemp +Topline/GB162,boiler,115,summertemp,summer temperature,uint8 (>=0<=45),C,true,number.boiler_summer_temperature,number.boiler_summertemp Topline/GB162,boiler,115,nofrostmode,nofrost mode,boolean, ,true,switch.boiler_nofrost_mode,switch.boiler_nofrostmode Topline/GB162,boiler,115,nofrosttemp,nofrost temperature,uint8 (>=0<=10),C,true,number.boiler_nofrost_temperature,number.boiler_nofrosttemp Topline/GB162,boiler,115,heatingactivated,heating activated,boolean, ,true,switch.boiler_heating_activated,switch.boiler_heatingactivated @@ -899,6 +910,7 @@ Topline/GB162,boiler,115,heatingpump,heating pump,boolean, ,false,binary_sensor. Topline/GB162,boiler,115,pumpmodmax,boiler pump max power,uint8 (>=0<=100),%,true,number.boiler_boiler_pump_max_power,number.boiler_pumpmodmax Topline/GB162,boiler,115,pumpmodmin,boiler pump min power,uint8 (>=0<=100),%,true,number.boiler_boiler_pump_min_power,number.boiler_pumpmodmin Topline/GB162,boiler,115,pumpmode,boiler pump mode,enum [proportional\|deltaP-1\|deltaP-2\|deltaP-3\|deltaP-4], ,true,select.boiler_boiler_pump_mode,select.boiler_pumpmode +Topline/GB162,boiler,115,pumpcharacter,boiler pump characteristic,enum [proportional\|150mbar\|200mbar\|250mbar\|300mbar\|350mbar\|400mbar], ,true,select.boiler_boiler_pump_characteristic,select.boiler_pumpcharacter Topline/GB162,boiler,115,pumpdelay,pump delay,uint8 (>=0<=60),minutes,true,number.boiler_pump_delay,number.boiler_pumpdelay Topline/GB162,boiler,115,setflowtemp,set flow temperature,uint8 (>=0<=254),C,false,sensor.boiler_set_flow_temperature,sensor.boiler_setflowtemp Topline/GB162,boiler,115,setburnpow,burner set power,uint8 (>=0<=100),%,false,sensor.boiler_burner_set_power,sensor.boiler_setburnpow @@ -920,11 +932,11 @@ Topline/GB162,boiler,115,maintenancedate,next maintenance date,string, ,true,sen Topline/GB162,boiler,115,emergencyops,emergency operation,boolean, ,true,switch.boiler_emergency_operation,switch.boiler_emergencyops Topline/GB162,boiler,115,emergencytemp,emergency temperature,uint8 (>=15<=70),C,true,number.boiler_emergency_temperature,number.boiler_emergencytemp Topline/GB162,boiler,115,meterheat,meter heating,uint24 (>=0<=1677721),kWh,false,sensor.boiler_meter_heating,sensor.boiler_meterheat -Topline/GB162,boiler,115,meterdhw,meter,uint24 (>=0<=1677721),kWh,false,sensor.boiler_dhw_meter,sensor.boiler_dhw_meterdhw +Topline/GB162,boiler,115,meter,meter,uint24 (>=0<=1677721),kWh,false,sensor.boiler_dhw_meter,sensor.boiler_dhw_meter Topline/GB162,boiler,115,gasmeterheat,gas meter heating,uint24 (>=0<=1677721),kWh,false,sensor.boiler_gas_meter_heating,sensor.boiler_gasmeterheat -Topline/GB162,boiler,115,gasmeterdhw,gas meter,uint24 (>=0<=1677721),kWh,false,sensor.boiler_dhw_gas_meter,sensor.boiler_dhw_gasmeterdhw +Topline/GB162,boiler,115,gasmeter,gas meter,uint24 (>=0<=1677721),kWh,false,sensor.boiler_dhw_gas_meter,sensor.boiler_dhw_gasmeter Topline/GB162,boiler,115,nrgheat2,energy heating 2,uint24 (>=0<=1677721),kWh,false,sensor.boiler_energy_heating_2,sensor.boiler_nrgheat2 -Topline/GB162,boiler,115,nrgdhw2,energy 2,uint24 (>=0<=1677721),kWh,false,sensor.boiler_dhw_energy_2,sensor.boiler_dhw_nrgdhw2 +Topline/GB162,boiler,115,nrg2,energy 2,uint24 (>=0<=1677721),kWh,false,sensor.boiler_dhw_energy_2,sensor.boiler_dhw_nrg2 Topline/GB162,boiler,115,tapactivated,turn on/off,boolean, ,true,switch.boiler_dhw_turn_on/off,switch.boiler_dhw_tapactivated Topline/GB162,boiler,115,settemp,set temperature,uint8 (>=0<=254),C,false,sensor.boiler_dhw_set_temperature,sensor.boiler_dhw_settemp Topline/GB162,boiler,115,seltemp,selected temperature,uint8 (>=0<=254),C,true,number.boiler_dhw_selected_temperature,number.boiler_dhw_seltemp @@ -968,7 +980,7 @@ Topline/GB162,boiler,115,workm,active time,time (>=0<=16777213),minutes,false,se Topline/GB162,boiler,115,nompower,nominal Power,uint8 (>=0<=254),kW,true,number.boiler_nominal_Power,number.boiler_nompower Topline/GB162,boiler,115,nrgtotal,total energy,uint24 (>=0<=167772),kWh,false,sensor.boiler_total_energy,sensor.boiler_nrgtotal Topline/GB162,boiler,115,nrgheat,energy heating,uint24 (>=0<=10000000),kWh,true,number.boiler_energy_heating,number.boiler_nrgheat -Topline/GB162,boiler,115,nrgdhw,energy,uint24 (>=0<=10000000),kWh,true,number.boiler_dhw_energy,number.boiler_dhw_nrgdhw +Topline/GB162,boiler,115,nrg,energy,uint24 (>=0<=10000000),kWh,true,number.boiler_dhw_energy,number.boiler_dhw_nrg Cascade MCM10,boiler,121,reset,reset,cmd [-\|maintenance\|error\|history\|message], ,true,sensor.boiler_reset,sensor.boiler_reset Cascade MCM10,boiler,121,heatingoff,force heating off,boolean, ,true,switch.boiler_force_heating_off,switch.boiler_heatingoff Cascade MCM10,boiler,121,heatingactive,heating active,boolean, ,false,binary_sensor.boiler_heating_active,binary_sensor.boiler_heatingactive @@ -1001,7 +1013,7 @@ Cascade MCM10,boiler,121,boil2hystoff,hysteresis stage 2 off temperature,int8 (> Cascade MCM10,boiler,121,curveon,heatingcurve on,boolean, ,true,switch.boiler_heatingcurve_on,switch.boiler_curveon Cascade MCM10,boiler,121,curvebase,heatingcurve base,uint8 (>=20<=90),C,true,number.boiler_heatingcurve_base,number.boiler_curvebase Cascade MCM10,boiler,121,curveend,heatingcurve end,uint8 (>=20<=90),C,true,number.boiler_heatingcurve_end,number.boiler_curveend -Cascade MCM10,boiler,121,summertemp,summer temperature,uint8 (>=0<=30),C,true,number.boiler_summer_temperature,number.boiler_summertemp +Cascade MCM10,boiler,121,summertemp,summer temperature,uint8 (>=0<=45),C,true,number.boiler_summer_temperature,number.boiler_summertemp Cascade MCM10,boiler,121,nofrostmode,nofrost mode,boolean, ,true,switch.boiler_nofrost_mode,switch.boiler_nofrostmode Cascade MCM10,boiler,121,nofrosttemp,nofrost temperature,uint8 (>=0<=10),C,true,number.boiler_nofrost_temperature,number.boiler_nofrosttemp Cascade MCM10,boiler,121,heatingactivated,heating activated,boolean, ,true,switch.boiler_heating_activated,switch.boiler_heatingactivated @@ -1010,6 +1022,7 @@ Cascade MCM10,boiler,121,heatingpump,heating pump,boolean, ,false,binary_sensor. Cascade MCM10,boiler,121,pumpmodmax,boiler pump max power,uint8 (>=0<=100),%,true,number.boiler_boiler_pump_max_power,number.boiler_pumpmodmax Cascade MCM10,boiler,121,pumpmodmin,boiler pump min power,uint8 (>=0<=100),%,true,number.boiler_boiler_pump_min_power,number.boiler_pumpmodmin Cascade MCM10,boiler,121,pumpmode,boiler pump mode,enum [proportional\|deltaP-1\|deltaP-2\|deltaP-3\|deltaP-4], ,true,select.boiler_boiler_pump_mode,select.boiler_pumpmode +Cascade MCM10,boiler,121,pumpcharacter,boiler pump characteristic,enum [proportional\|150mbar\|200mbar\|250mbar\|300mbar\|350mbar\|400mbar], ,true,select.boiler_boiler_pump_characteristic,select.boiler_pumpcharacter Cascade MCM10,boiler,121,pumpdelay,pump delay,uint8 (>=0<=60),minutes,true,number.boiler_pump_delay,number.boiler_pumpdelay Cascade MCM10,boiler,121,setflowtemp,set flow temperature,uint8 (>=0<=254),C,false,sensor.boiler_set_flow_temperature,sensor.boiler_setflowtemp Cascade MCM10,boiler,121,setburnpow,burner set power,uint8 (>=0<=100),%,false,sensor.boiler_burner_set_power,sensor.boiler_setburnpow @@ -1031,11 +1044,11 @@ Cascade MCM10,boiler,121,maintenancedate,next maintenance date,string, ,true,sen Cascade MCM10,boiler,121,emergencyops,emergency operation,boolean, ,true,switch.boiler_emergency_operation,switch.boiler_emergencyops Cascade MCM10,boiler,121,emergencytemp,emergency temperature,uint8 (>=15<=70),C,true,number.boiler_emergency_temperature,number.boiler_emergencytemp Cascade MCM10,boiler,121,meterheat,meter heating,uint24 (>=0<=1677721),kWh,false,sensor.boiler_meter_heating,sensor.boiler_meterheat -Cascade MCM10,boiler,121,meterdhw,meter,uint24 (>=0<=1677721),kWh,false,sensor.boiler_dhw_meter,sensor.boiler_dhw_meterdhw +Cascade MCM10,boiler,121,meter,meter,uint24 (>=0<=1677721),kWh,false,sensor.boiler_dhw_meter,sensor.boiler_dhw_meter Cascade MCM10,boiler,121,gasmeterheat,gas meter heating,uint24 (>=0<=1677721),kWh,false,sensor.boiler_gas_meter_heating,sensor.boiler_gasmeterheat -Cascade MCM10,boiler,121,gasmeterdhw,gas meter,uint24 (>=0<=1677721),kWh,false,sensor.boiler_dhw_gas_meter,sensor.boiler_dhw_gasmeterdhw +Cascade MCM10,boiler,121,gasmeter,gas meter,uint24 (>=0<=1677721),kWh,false,sensor.boiler_dhw_gas_meter,sensor.boiler_dhw_gasmeter Cascade MCM10,boiler,121,nrgheat2,energy heating 2,uint24 (>=0<=1677721),kWh,false,sensor.boiler_energy_heating_2,sensor.boiler_nrgheat2 -Cascade MCM10,boiler,121,nrgdhw2,energy 2,uint24 (>=0<=1677721),kWh,false,sensor.boiler_dhw_energy_2,sensor.boiler_dhw_nrgdhw2 +Cascade MCM10,boiler,121,nrg2,energy 2,uint24 (>=0<=1677721),kWh,false,sensor.boiler_dhw_energy_2,sensor.boiler_dhw_nrg2 Cascade MCM10,boiler,121,tapactivated,turn on/off,boolean, ,true,switch.boiler_dhw_turn_on/off,switch.boiler_dhw_tapactivated Cascade MCM10,boiler,121,settemp,set temperature,uint8 (>=0<=254),C,false,sensor.boiler_dhw_set_temperature,sensor.boiler_dhw_settemp Cascade MCM10,boiler,121,seltemp,selected temperature,uint8 (>=0<=254),C,true,number.boiler_dhw_selected_temperature,number.boiler_dhw_seltemp @@ -1079,7 +1092,7 @@ Cascade MCM10,boiler,121,workm,active time,time (>=0<=16777213),minutes,false,se Cascade MCM10,boiler,121,nompower,nominal Power,uint8 (>=0<=254),kW,true,number.boiler_nominal_Power,number.boiler_nompower Cascade MCM10,boiler,121,nrgtotal,total energy,uint24 (>=0<=167772),kWh,false,sensor.boiler_total_energy,sensor.boiler_nrgtotal Cascade MCM10,boiler,121,nrgheat,energy heating,uint24 (>=0<=10000000),kWh,true,number.boiler_energy_heating,number.boiler_nrgheat -Cascade MCM10,boiler,121,nrgdhw,energy,uint24 (>=0<=10000000),kWh,true,number.boiler_dhw_energy,number.boiler_dhw_nrgdhw +Cascade MCM10,boiler,121,nrg,energy,uint24 (>=0<=10000000),kWh,true,number.boiler_dhw_energy,number.boiler_dhw_nrg Proline,boiler,122,reset,reset,cmd [-\|maintenance\|error\|history\|message], ,true,sensor.boiler_reset,sensor.boiler_reset Proline,boiler,122,heatingoff,force heating off,boolean, ,true,switch.boiler_force_heating_off,switch.boiler_heatingoff Proline,boiler,122,heatingactive,heating active,boolean, ,false,binary_sensor.boiler_heating_active,binary_sensor.boiler_heatingactive @@ -1112,7 +1125,7 @@ Proline,boiler,122,boil2hystoff,hysteresis stage 2 off temperature,int8 (>=0<=20 Proline,boiler,122,curveon,heatingcurve on,boolean, ,true,switch.boiler_heatingcurve_on,switch.boiler_curveon Proline,boiler,122,curvebase,heatingcurve base,uint8 (>=20<=90),C,true,number.boiler_heatingcurve_base,number.boiler_curvebase Proline,boiler,122,curveend,heatingcurve end,uint8 (>=20<=90),C,true,number.boiler_heatingcurve_end,number.boiler_curveend -Proline,boiler,122,summertemp,summer temperature,uint8 (>=0<=30),C,true,number.boiler_summer_temperature,number.boiler_summertemp +Proline,boiler,122,summertemp,summer temperature,uint8 (>=0<=45),C,true,number.boiler_summer_temperature,number.boiler_summertemp Proline,boiler,122,nofrostmode,nofrost mode,boolean, ,true,switch.boiler_nofrost_mode,switch.boiler_nofrostmode Proline,boiler,122,nofrosttemp,nofrost temperature,uint8 (>=0<=10),C,true,number.boiler_nofrost_temperature,number.boiler_nofrosttemp Proline,boiler,122,heatingactivated,heating activated,boolean, ,true,switch.boiler_heating_activated,switch.boiler_heatingactivated @@ -1121,6 +1134,7 @@ Proline,boiler,122,heatingpump,heating pump,boolean, ,false,binary_sensor.boiler Proline,boiler,122,pumpmodmax,boiler pump max power,uint8 (>=0<=100),%,true,number.boiler_boiler_pump_max_power,number.boiler_pumpmodmax Proline,boiler,122,pumpmodmin,boiler pump min power,uint8 (>=0<=100),%,true,number.boiler_boiler_pump_min_power,number.boiler_pumpmodmin Proline,boiler,122,pumpmode,boiler pump mode,enum [proportional\|deltaP-1\|deltaP-2\|deltaP-3\|deltaP-4], ,true,select.boiler_boiler_pump_mode,select.boiler_pumpmode +Proline,boiler,122,pumpcharacter,boiler pump characteristic,enum [proportional\|150mbar\|200mbar\|250mbar\|300mbar\|350mbar\|400mbar], ,true,select.boiler_boiler_pump_characteristic,select.boiler_pumpcharacter Proline,boiler,122,pumpdelay,pump delay,uint8 (>=0<=60),minutes,true,number.boiler_pump_delay,number.boiler_pumpdelay Proline,boiler,122,setflowtemp,set flow temperature,uint8 (>=0<=254),C,false,sensor.boiler_set_flow_temperature,sensor.boiler_setflowtemp Proline,boiler,122,setburnpow,burner set power,uint8 (>=0<=100),%,false,sensor.boiler_burner_set_power,sensor.boiler_setburnpow @@ -1142,11 +1156,11 @@ Proline,boiler,122,maintenancedate,next maintenance date,string, ,true,sensor.bo Proline,boiler,122,emergencyops,emergency operation,boolean, ,true,switch.boiler_emergency_operation,switch.boiler_emergencyops Proline,boiler,122,emergencytemp,emergency temperature,uint8 (>=15<=70),C,true,number.boiler_emergency_temperature,number.boiler_emergencytemp Proline,boiler,122,meterheat,meter heating,uint24 (>=0<=1677721),kWh,false,sensor.boiler_meter_heating,sensor.boiler_meterheat -Proline,boiler,122,meterdhw,meter,uint24 (>=0<=1677721),kWh,false,sensor.boiler_dhw_meter,sensor.boiler_dhw_meterdhw +Proline,boiler,122,meter,meter,uint24 (>=0<=1677721),kWh,false,sensor.boiler_dhw_meter,sensor.boiler_dhw_meter Proline,boiler,122,gasmeterheat,gas meter heating,uint24 (>=0<=1677721),kWh,false,sensor.boiler_gas_meter_heating,sensor.boiler_gasmeterheat -Proline,boiler,122,gasmeterdhw,gas meter,uint24 (>=0<=1677721),kWh,false,sensor.boiler_dhw_gas_meter,sensor.boiler_dhw_gasmeterdhw +Proline,boiler,122,gasmeter,gas meter,uint24 (>=0<=1677721),kWh,false,sensor.boiler_dhw_gas_meter,sensor.boiler_dhw_gasmeter Proline,boiler,122,nrgheat2,energy heating 2,uint24 (>=0<=1677721),kWh,false,sensor.boiler_energy_heating_2,sensor.boiler_nrgheat2 -Proline,boiler,122,nrgdhw2,energy 2,uint24 (>=0<=1677721),kWh,false,sensor.boiler_dhw_energy_2,sensor.boiler_dhw_nrgdhw2 +Proline,boiler,122,nrg2,energy 2,uint24 (>=0<=1677721),kWh,false,sensor.boiler_dhw_energy_2,sensor.boiler_dhw_nrg2 Proline,boiler,122,tapactivated,turn on/off,boolean, ,true,switch.boiler_dhw_turn_on/off,switch.boiler_dhw_tapactivated Proline,boiler,122,settemp,set temperature,uint8 (>=0<=254),C,false,sensor.boiler_dhw_set_temperature,sensor.boiler_dhw_settemp Proline,boiler,122,seltemp,selected temperature,uint8 (>=0<=254),C,true,number.boiler_dhw_selected_temperature,number.boiler_dhw_seltemp @@ -1190,7 +1204,7 @@ Proline,boiler,122,workm,active time,time (>=0<=16777213),minutes,false,sensor.b Proline,boiler,122,nompower,nominal Power,uint8 (>=0<=254),kW,true,number.boiler_nominal_Power,number.boiler_nompower Proline,boiler,122,nrgtotal,total energy,uint24 (>=0<=167772),kWh,false,sensor.boiler_total_energy,sensor.boiler_nrgtotal Proline,boiler,122,nrgheat,energy heating,uint24 (>=0<=10000000),kWh,true,number.boiler_energy_heating,number.boiler_nrgheat -Proline,boiler,122,nrgdhw,energy,uint24 (>=0<=10000000),kWh,true,number.boiler_dhw_energy,number.boiler_dhw_nrgdhw +Proline,boiler,122,nrg,energy,uint24 (>=0<=10000000),kWh,true,number.boiler_dhw_energy,number.boiler_dhw_nrg GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,reset,reset,cmd [-\|maintenance\|error\|history\|message], ,true,sensor.boiler_reset,sensor.boiler_reset GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,heatingoff,force heating off,boolean, ,true,switch.boiler_force_heating_off,switch.boiler_heatingoff GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,heatingactive,heating active,boolean, ,false,binary_sensor.boiler_heating_active,binary_sensor.boiler_heatingactive @@ -1223,7 +1237,7 @@ GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,boil2hystoff,hysteresis stage 2 GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,curveon,heatingcurve on,boolean, ,true,switch.boiler_heatingcurve_on,switch.boiler_curveon GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,curvebase,heatingcurve base,uint8 (>=20<=90),C,true,number.boiler_heatingcurve_base,number.boiler_curvebase GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,curveend,heatingcurve end,uint8 (>=20<=90),C,true,number.boiler_heatingcurve_end,number.boiler_curveend -GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,summertemp,summer temperature,uint8 (>=0<=30),C,true,number.boiler_summer_temperature,number.boiler_summertemp +GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,summertemp,summer temperature,uint8 (>=0<=45),C,true,number.boiler_summer_temperature,number.boiler_summertemp GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,nofrostmode,nofrost mode,boolean, ,true,switch.boiler_nofrost_mode,switch.boiler_nofrostmode GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,nofrosttemp,nofrost temperature,uint8 (>=0<=10),C,true,number.boiler_nofrost_temperature,number.boiler_nofrosttemp GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,heatingactivated,heating activated,boolean, ,true,switch.boiler_heating_activated,switch.boiler_heatingactivated @@ -1232,6 +1246,7 @@ GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,heatingpump,heating pump,boolean GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,pumpmodmax,boiler pump max power,uint8 (>=0<=100),%,true,number.boiler_boiler_pump_max_power,number.boiler_pumpmodmax GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,pumpmodmin,boiler pump min power,uint8 (>=0<=100),%,true,number.boiler_boiler_pump_min_power,number.boiler_pumpmodmin GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,pumpmode,boiler pump mode,enum [proportional\|deltaP-1\|deltaP-2\|deltaP-3\|deltaP-4], ,true,select.boiler_boiler_pump_mode,select.boiler_pumpmode +GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,pumpcharacter,boiler pump characteristic,enum [proportional\|150mbar\|200mbar\|250mbar\|300mbar\|350mbar\|400mbar], ,true,select.boiler_boiler_pump_characteristic,select.boiler_pumpcharacter GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,pumpdelay,pump delay,uint8 (>=0<=60),minutes,true,number.boiler_pump_delay,number.boiler_pumpdelay GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,setflowtemp,set flow temperature,uint8 (>=0<=254),C,false,sensor.boiler_set_flow_temperature,sensor.boiler_setflowtemp GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,setburnpow,burner set power,uint8 (>=0<=100),%,false,sensor.boiler_burner_set_power,sensor.boiler_setburnpow @@ -1253,11 +1268,11 @@ GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,maintenancedate,next maintenance GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,emergencyops,emergency operation,boolean, ,true,switch.boiler_emergency_operation,switch.boiler_emergencyops GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,emergencytemp,emergency temperature,uint8 (>=15<=70),C,true,number.boiler_emergency_temperature,number.boiler_emergencytemp GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,meterheat,meter heating,uint24 (>=0<=1677721),kWh,false,sensor.boiler_meter_heating,sensor.boiler_meterheat -GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,meterdhw,meter,uint24 (>=0<=1677721),kWh,false,sensor.boiler_dhw_meter,sensor.boiler_dhw_meterdhw +GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,meter,meter,uint24 (>=0<=1677721),kWh,false,sensor.boiler_dhw_meter,sensor.boiler_dhw_meter GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,gasmeterheat,gas meter heating,uint24 (>=0<=1677721),kWh,false,sensor.boiler_gas_meter_heating,sensor.boiler_gasmeterheat -GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,gasmeterdhw,gas meter,uint24 (>=0<=1677721),kWh,false,sensor.boiler_dhw_gas_meter,sensor.boiler_dhw_gasmeterdhw +GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,gasmeter,gas meter,uint24 (>=0<=1677721),kWh,false,sensor.boiler_dhw_gas_meter,sensor.boiler_dhw_gasmeter GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,nrgheat2,energy heating 2,uint24 (>=0<=1677721),kWh,false,sensor.boiler_energy_heating_2,sensor.boiler_nrgheat2 -GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,nrgdhw2,energy 2,uint24 (>=0<=1677721),kWh,false,sensor.boiler_dhw_energy_2,sensor.boiler_dhw_nrgdhw2 +GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,nrg2,energy 2,uint24 (>=0<=1677721),kWh,false,sensor.boiler_dhw_energy_2,sensor.boiler_dhw_nrg2 GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,tapactivated,turn on/off,boolean, ,true,switch.boiler_dhw_turn_on/off,switch.boiler_dhw_tapactivated GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,settemp,set temperature,uint8 (>=0<=254),C,false,sensor.boiler_dhw_set_temperature,sensor.boiler_dhw_settemp GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,seltemp,selected temperature,uint8 (>=0<=254),C,true,number.boiler_dhw_selected_temperature,number.boiler_dhw_seltemp @@ -1301,7 +1316,7 @@ GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,workm,active time,time (>=0<=167 GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,nompower,nominal Power,uint8 (>=0<=254),kW,true,number.boiler_nominal_Power,number.boiler_nompower GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,nrgtotal,total energy,uint24 (>=0<=167772),kWh,false,sensor.boiler_total_energy,sensor.boiler_nrgtotal GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,nrgheat,energy heating,uint24 (>=0<=10000000),kWh,true,number.boiler_energy_heating,number.boiler_nrgheat -GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,nrgdhw,energy,uint24 (>=0<=10000000),kWh,true,number.boiler_dhw_energy,number.boiler_dhw_nrgdhw +GBx72/Trendline/Cerapur/Greenstar Si,boiler,123,nrg,energy,uint24 (>=0<=10000000),kWh,true,number.boiler_dhw_energy,number.boiler_dhw_nrg GB212,boiler,131,reset,reset,cmd [-\|maintenance\|error\|history\|message], ,true,sensor.boiler_reset,sensor.boiler_reset GB212,boiler,131,heatingoff,force heating off,boolean, ,true,switch.boiler_force_heating_off,switch.boiler_heatingoff GB212,boiler,131,heatingactive,heating active,boolean, ,false,binary_sensor.boiler_heating_active,binary_sensor.boiler_heatingactive @@ -1334,7 +1349,7 @@ GB212,boiler,131,boil2hystoff,hysteresis stage 2 off temperature,int8 (>=0<=20), GB212,boiler,131,curveon,heatingcurve on,boolean, ,true,switch.boiler_heatingcurve_on,switch.boiler_curveon GB212,boiler,131,curvebase,heatingcurve base,uint8 (>=20<=90),C,true,number.boiler_heatingcurve_base,number.boiler_curvebase GB212,boiler,131,curveend,heatingcurve end,uint8 (>=20<=90),C,true,number.boiler_heatingcurve_end,number.boiler_curveend -GB212,boiler,131,summertemp,summer temperature,uint8 (>=0<=30),C,true,number.boiler_summer_temperature,number.boiler_summertemp +GB212,boiler,131,summertemp,summer temperature,uint8 (>=0<=45),C,true,number.boiler_summer_temperature,number.boiler_summertemp GB212,boiler,131,nofrostmode,nofrost mode,boolean, ,true,switch.boiler_nofrost_mode,switch.boiler_nofrostmode GB212,boiler,131,nofrosttemp,nofrost temperature,uint8 (>=0<=10),C,true,number.boiler_nofrost_temperature,number.boiler_nofrosttemp GB212,boiler,131,heatingactivated,heating activated,boolean, ,true,switch.boiler_heating_activated,switch.boiler_heatingactivated @@ -1343,6 +1358,7 @@ GB212,boiler,131,heatingpump,heating pump,boolean, ,false,binary_sensor.boiler_h GB212,boiler,131,pumpmodmax,boiler pump max power,uint8 (>=0<=100),%,true,number.boiler_boiler_pump_max_power,number.boiler_pumpmodmax GB212,boiler,131,pumpmodmin,boiler pump min power,uint8 (>=0<=100),%,true,number.boiler_boiler_pump_min_power,number.boiler_pumpmodmin GB212,boiler,131,pumpmode,boiler pump mode,enum [proportional\|deltaP-1\|deltaP-2\|deltaP-3\|deltaP-4], ,true,select.boiler_boiler_pump_mode,select.boiler_pumpmode +GB212,boiler,131,pumpcharacter,boiler pump characteristic,enum [proportional\|150mbar\|200mbar\|250mbar\|300mbar\|350mbar\|400mbar], ,true,select.boiler_boiler_pump_characteristic,select.boiler_pumpcharacter GB212,boiler,131,pumpdelay,pump delay,uint8 (>=0<=60),minutes,true,number.boiler_pump_delay,number.boiler_pumpdelay GB212,boiler,131,setflowtemp,set flow temperature,uint8 (>=0<=254),C,false,sensor.boiler_set_flow_temperature,sensor.boiler_setflowtemp GB212,boiler,131,setburnpow,burner set power,uint8 (>=0<=100),%,false,sensor.boiler_burner_set_power,sensor.boiler_setburnpow @@ -1364,11 +1380,11 @@ GB212,boiler,131,maintenancedate,next maintenance date,string, ,true,sensor.boil GB212,boiler,131,emergencyops,emergency operation,boolean, ,true,switch.boiler_emergency_operation,switch.boiler_emergencyops GB212,boiler,131,emergencytemp,emergency temperature,uint8 (>=15<=70),C,true,number.boiler_emergency_temperature,number.boiler_emergencytemp GB212,boiler,131,meterheat,meter heating,uint24 (>=0<=1677721),kWh,false,sensor.boiler_meter_heating,sensor.boiler_meterheat -GB212,boiler,131,meterdhw,meter,uint24 (>=0<=1677721),kWh,false,sensor.boiler_dhw_meter,sensor.boiler_dhw_meterdhw +GB212,boiler,131,meter,meter,uint24 (>=0<=1677721),kWh,false,sensor.boiler_dhw_meter,sensor.boiler_dhw_meter GB212,boiler,131,gasmeterheat,gas meter heating,uint24 (>=0<=1677721),kWh,false,sensor.boiler_gas_meter_heating,sensor.boiler_gasmeterheat -GB212,boiler,131,gasmeterdhw,gas meter,uint24 (>=0<=1677721),kWh,false,sensor.boiler_dhw_gas_meter,sensor.boiler_dhw_gasmeterdhw +GB212,boiler,131,gasmeter,gas meter,uint24 (>=0<=1677721),kWh,false,sensor.boiler_dhw_gas_meter,sensor.boiler_dhw_gasmeter GB212,boiler,131,nrgheat2,energy heating 2,uint24 (>=0<=1677721),kWh,false,sensor.boiler_energy_heating_2,sensor.boiler_nrgheat2 -GB212,boiler,131,nrgdhw2,energy 2,uint24 (>=0<=1677721),kWh,false,sensor.boiler_dhw_energy_2,sensor.boiler_dhw_nrgdhw2 +GB212,boiler,131,nrg2,energy 2,uint24 (>=0<=1677721),kWh,false,sensor.boiler_dhw_energy_2,sensor.boiler_dhw_nrg2 GB212,boiler,131,tapactivated,turn on/off,boolean, ,true,switch.boiler_dhw_turn_on/off,switch.boiler_dhw_tapactivated GB212,boiler,131,settemp,set temperature,uint8 (>=0<=254),C,false,sensor.boiler_dhw_set_temperature,sensor.boiler_dhw_settemp GB212,boiler,131,seltemp,selected temperature,uint8 (>=0<=254),C,true,number.boiler_dhw_selected_temperature,number.boiler_dhw_seltemp @@ -1412,7 +1428,7 @@ GB212,boiler,131,workm,active time,time (>=0<=16777213),minutes,false,sensor.boi GB212,boiler,131,nompower,nominal Power,uint8 (>=0<=254),kW,true,number.boiler_nominal_Power,number.boiler_nompower GB212,boiler,131,nrgtotal,total energy,uint24 (>=0<=167772),kWh,false,sensor.boiler_total_energy,sensor.boiler_nrgtotal GB212,boiler,131,nrgheat,energy heating,uint24 (>=0<=10000000),kWh,true,number.boiler_energy_heating,number.boiler_nrgheat -GB212,boiler,131,nrgdhw,energy,uint24 (>=0<=10000000),kWh,true,number.boiler_dhw_energy,number.boiler_dhw_nrgdhw +GB212,boiler,131,nrg,energy,uint24 (>=0<=10000000),kWh,true,number.boiler_dhw_energy,number.boiler_dhw_nrg GC7000F,boiler,132,reset,reset,cmd [-\|maintenance\|error\|history\|message], ,true,sensor.boiler_reset,sensor.boiler_reset GC7000F,boiler,132,heatingoff,force heating off,boolean, ,true,switch.boiler_force_heating_off,switch.boiler_heatingoff GC7000F,boiler,132,heatingactive,heating active,boolean, ,false,binary_sensor.boiler_heating_active,binary_sensor.boiler_heatingactive @@ -1445,7 +1461,7 @@ GC7000F,boiler,132,boil2hystoff,hysteresis stage 2 off temperature,int8 (>=0<=20 GC7000F,boiler,132,curveon,heatingcurve on,boolean, ,true,switch.boiler_heatingcurve_on,switch.boiler_curveon GC7000F,boiler,132,curvebase,heatingcurve base,uint8 (>=20<=90),C,true,number.boiler_heatingcurve_base,number.boiler_curvebase GC7000F,boiler,132,curveend,heatingcurve end,uint8 (>=20<=90),C,true,number.boiler_heatingcurve_end,number.boiler_curveend -GC7000F,boiler,132,summertemp,summer temperature,uint8 (>=0<=30),C,true,number.boiler_summer_temperature,number.boiler_summertemp +GC7000F,boiler,132,summertemp,summer temperature,uint8 (>=0<=45),C,true,number.boiler_summer_temperature,number.boiler_summertemp GC7000F,boiler,132,nofrostmode,nofrost mode,boolean, ,true,switch.boiler_nofrost_mode,switch.boiler_nofrostmode GC7000F,boiler,132,nofrosttemp,nofrost temperature,uint8 (>=0<=10),C,true,number.boiler_nofrost_temperature,number.boiler_nofrosttemp GC7000F,boiler,132,heatingactivated,heating activated,boolean, ,true,switch.boiler_heating_activated,switch.boiler_heatingactivated @@ -1454,6 +1470,7 @@ GC7000F,boiler,132,heatingpump,heating pump,boolean, ,false,binary_sensor.boiler GC7000F,boiler,132,pumpmodmax,boiler pump max power,uint8 (>=0<=100),%,true,number.boiler_boiler_pump_max_power,number.boiler_pumpmodmax GC7000F,boiler,132,pumpmodmin,boiler pump min power,uint8 (>=0<=100),%,true,number.boiler_boiler_pump_min_power,number.boiler_pumpmodmin GC7000F,boiler,132,pumpmode,boiler pump mode,enum [proportional\|deltaP-1\|deltaP-2\|deltaP-3\|deltaP-4], ,true,select.boiler_boiler_pump_mode,select.boiler_pumpmode +GC7000F,boiler,132,pumpcharacter,boiler pump characteristic,enum [proportional\|150mbar\|200mbar\|250mbar\|300mbar\|350mbar\|400mbar], ,true,select.boiler_boiler_pump_characteristic,select.boiler_pumpcharacter GC7000F,boiler,132,pumpdelay,pump delay,uint8 (>=0<=60),minutes,true,number.boiler_pump_delay,number.boiler_pumpdelay GC7000F,boiler,132,setflowtemp,set flow temperature,uint8 (>=0<=254),C,false,sensor.boiler_set_flow_temperature,sensor.boiler_setflowtemp GC7000F,boiler,132,setburnpow,burner set power,uint8 (>=0<=100),%,false,sensor.boiler_burner_set_power,sensor.boiler_setburnpow @@ -1475,11 +1492,11 @@ GC7000F,boiler,132,maintenancedate,next maintenance date,string, ,true,sensor.bo GC7000F,boiler,132,emergencyops,emergency operation,boolean, ,true,switch.boiler_emergency_operation,switch.boiler_emergencyops GC7000F,boiler,132,emergencytemp,emergency temperature,uint8 (>=15<=70),C,true,number.boiler_emergency_temperature,number.boiler_emergencytemp GC7000F,boiler,132,meterheat,meter heating,uint24 (>=0<=1677721),kWh,false,sensor.boiler_meter_heating,sensor.boiler_meterheat -GC7000F,boiler,132,meterdhw,meter,uint24 (>=0<=1677721),kWh,false,sensor.boiler_dhw_meter,sensor.boiler_dhw_meterdhw +GC7000F,boiler,132,meter,meter,uint24 (>=0<=1677721),kWh,false,sensor.boiler_dhw_meter,sensor.boiler_dhw_meter GC7000F,boiler,132,gasmeterheat,gas meter heating,uint24 (>=0<=1677721),kWh,false,sensor.boiler_gas_meter_heating,sensor.boiler_gasmeterheat -GC7000F,boiler,132,gasmeterdhw,gas meter,uint24 (>=0<=1677721),kWh,false,sensor.boiler_dhw_gas_meter,sensor.boiler_dhw_gasmeterdhw +GC7000F,boiler,132,gasmeter,gas meter,uint24 (>=0<=1677721),kWh,false,sensor.boiler_dhw_gas_meter,sensor.boiler_dhw_gasmeter GC7000F,boiler,132,nrgheat2,energy heating 2,uint24 (>=0<=1677721),kWh,false,sensor.boiler_energy_heating_2,sensor.boiler_nrgheat2 -GC7000F,boiler,132,nrgdhw2,energy 2,uint24 (>=0<=1677721),kWh,false,sensor.boiler_dhw_energy_2,sensor.boiler_dhw_nrgdhw2 +GC7000F,boiler,132,nrg2,energy 2,uint24 (>=0<=1677721),kWh,false,sensor.boiler_dhw_energy_2,sensor.boiler_dhw_nrg2 GC7000F,boiler,132,tapactivated,turn on/off,boolean, ,true,switch.boiler_dhw_turn_on/off,switch.boiler_dhw_tapactivated GC7000F,boiler,132,settemp,set temperature,uint8 (>=0<=254),C,false,sensor.boiler_dhw_set_temperature,sensor.boiler_dhw_settemp GC7000F,boiler,132,seltemp,selected temperature,uint8 (>=0<=254),C,true,number.boiler_dhw_selected_temperature,number.boiler_dhw_seltemp @@ -1523,7 +1540,7 @@ GC7000F,boiler,132,workm,active time,time (>=0<=16777213),minutes,false,sensor.b GC7000F,boiler,132,nompower,nominal Power,uint8 (>=0<=254),kW,true,number.boiler_nominal_Power,number.boiler_nompower GC7000F,boiler,132,nrgtotal,total energy,uint24 (>=0<=167772),kWh,false,sensor.boiler_total_energy,sensor.boiler_nrgtotal GC7000F,boiler,132,nrgheat,energy heating,uint24 (>=0<=10000000),kWh,true,number.boiler_energy_heating,number.boiler_nrgheat -GC7000F,boiler,132,nrgdhw,energy,uint24 (>=0<=10000000),kWh,true,number.boiler_dhw_energy,number.boiler_dhw_nrgdhw +GC7000F,boiler,132,nrg,energy,uint24 (>=0<=10000000),kWh,true,number.boiler_dhw_energy,number.boiler_dhw_nrg Logano GB125/KB195i/Logamatic MC110,boiler,133,reset,reset,cmd [-\|maintenance\|error\|history\|message], ,true,sensor.boiler_reset,sensor.boiler_reset Logano GB125/KB195i/Logamatic MC110,boiler,133,heatingoff,force heating off,boolean, ,true,switch.boiler_force_heating_off,switch.boiler_heatingoff Logano GB125/KB195i/Logamatic MC110,boiler,133,heatingactive,heating active,boolean, ,false,binary_sensor.boiler_heating_active,binary_sensor.boiler_heatingactive @@ -1556,7 +1573,7 @@ Logano GB125/KB195i/Logamatic MC110,boiler,133,boil2hystoff,hysteresis stage 2 o Logano GB125/KB195i/Logamatic MC110,boiler,133,curveon,heatingcurve on,boolean, ,true,switch.boiler_heatingcurve_on,switch.boiler_curveon Logano GB125/KB195i/Logamatic MC110,boiler,133,curvebase,heatingcurve base,uint8 (>=20<=90),C,true,number.boiler_heatingcurve_base,number.boiler_curvebase Logano GB125/KB195i/Logamatic MC110,boiler,133,curveend,heatingcurve end,uint8 (>=20<=90),C,true,number.boiler_heatingcurve_end,number.boiler_curveend -Logano GB125/KB195i/Logamatic MC110,boiler,133,summertemp,summer temperature,uint8 (>=0<=30),C,true,number.boiler_summer_temperature,number.boiler_summertemp +Logano GB125/KB195i/Logamatic MC110,boiler,133,summertemp,summer temperature,uint8 (>=0<=45),C,true,number.boiler_summer_temperature,number.boiler_summertemp Logano GB125/KB195i/Logamatic MC110,boiler,133,nofrostmode,nofrost mode,boolean, ,true,switch.boiler_nofrost_mode,switch.boiler_nofrostmode Logano GB125/KB195i/Logamatic MC110,boiler,133,nofrosttemp,nofrost temperature,uint8 (>=0<=10),C,true,number.boiler_nofrost_temperature,number.boiler_nofrosttemp Logano GB125/KB195i/Logamatic MC110,boiler,133,heatingactivated,heating activated,boolean, ,true,switch.boiler_heating_activated,switch.boiler_heatingactivated @@ -1565,6 +1582,7 @@ Logano GB125/KB195i/Logamatic MC110,boiler,133,heatingpump,heating pump,boolean, Logano GB125/KB195i/Logamatic MC110,boiler,133,pumpmodmax,boiler pump max power,uint8 (>=0<=100),%,true,number.boiler_boiler_pump_max_power,number.boiler_pumpmodmax Logano GB125/KB195i/Logamatic MC110,boiler,133,pumpmodmin,boiler pump min power,uint8 (>=0<=100),%,true,number.boiler_boiler_pump_min_power,number.boiler_pumpmodmin Logano GB125/KB195i/Logamatic MC110,boiler,133,pumpmode,boiler pump mode,enum [proportional\|deltaP-1\|deltaP-2\|deltaP-3\|deltaP-4], ,true,select.boiler_boiler_pump_mode,select.boiler_pumpmode +Logano GB125/KB195i/Logamatic MC110,boiler,133,pumpcharacter,boiler pump characteristic,enum [proportional\|150mbar\|200mbar\|250mbar\|300mbar\|350mbar\|400mbar], ,true,select.boiler_boiler_pump_characteristic,select.boiler_pumpcharacter Logano GB125/KB195i/Logamatic MC110,boiler,133,pumpdelay,pump delay,uint8 (>=0<=60),minutes,true,number.boiler_pump_delay,number.boiler_pumpdelay Logano GB125/KB195i/Logamatic MC110,boiler,133,setflowtemp,set flow temperature,uint8 (>=0<=254),C,false,sensor.boiler_set_flow_temperature,sensor.boiler_setflowtemp Logano GB125/KB195i/Logamatic MC110,boiler,133,setburnpow,burner set power,uint8 (>=0<=100),%,false,sensor.boiler_burner_set_power,sensor.boiler_setburnpow @@ -1586,11 +1604,11 @@ Logano GB125/KB195i/Logamatic MC110,boiler,133,maintenancedate,next maintenance Logano GB125/KB195i/Logamatic MC110,boiler,133,emergencyops,emergency operation,boolean, ,true,switch.boiler_emergency_operation,switch.boiler_emergencyops Logano GB125/KB195i/Logamatic MC110,boiler,133,emergencytemp,emergency temperature,uint8 (>=15<=70),C,true,number.boiler_emergency_temperature,number.boiler_emergencytemp Logano GB125/KB195i/Logamatic MC110,boiler,133,meterheat,meter heating,uint24 (>=0<=1677721),kWh,false,sensor.boiler_meter_heating,sensor.boiler_meterheat -Logano GB125/KB195i/Logamatic MC110,boiler,133,meterdhw,meter,uint24 (>=0<=1677721),kWh,false,sensor.boiler_dhw_meter,sensor.boiler_dhw_meterdhw +Logano GB125/KB195i/Logamatic MC110,boiler,133,meter,meter,uint24 (>=0<=1677721),kWh,false,sensor.boiler_dhw_meter,sensor.boiler_dhw_meter Logano GB125/KB195i/Logamatic MC110,boiler,133,gasmeterheat,gas meter heating,uint24 (>=0<=1677721),kWh,false,sensor.boiler_gas_meter_heating,sensor.boiler_gasmeterheat -Logano GB125/KB195i/Logamatic MC110,boiler,133,gasmeterdhw,gas meter,uint24 (>=0<=1677721),kWh,false,sensor.boiler_dhw_gas_meter,sensor.boiler_dhw_gasmeterdhw +Logano GB125/KB195i/Logamatic MC110,boiler,133,gasmeter,gas meter,uint24 (>=0<=1677721),kWh,false,sensor.boiler_dhw_gas_meter,sensor.boiler_dhw_gasmeter Logano GB125/KB195i/Logamatic MC110,boiler,133,nrgheat2,energy heating 2,uint24 (>=0<=1677721),kWh,false,sensor.boiler_energy_heating_2,sensor.boiler_nrgheat2 -Logano GB125/KB195i/Logamatic MC110,boiler,133,nrgdhw2,energy 2,uint24 (>=0<=1677721),kWh,false,sensor.boiler_dhw_energy_2,sensor.boiler_dhw_nrgdhw2 +Logano GB125/KB195i/Logamatic MC110,boiler,133,nrg2,energy 2,uint24 (>=0<=1677721),kWh,false,sensor.boiler_dhw_energy_2,sensor.boiler_dhw_nrg2 Logano GB125/KB195i/Logamatic MC110,boiler,133,tapactivated,turn on/off,boolean, ,true,switch.boiler_dhw_turn_on/off,switch.boiler_dhw_tapactivated Logano GB125/KB195i/Logamatic MC110,boiler,133,settemp,set temperature,uint8 (>=0<=254),C,false,sensor.boiler_dhw_set_temperature,sensor.boiler_dhw_settemp Logano GB125/KB195i/Logamatic MC110,boiler,133,seltemp,selected temperature,uint8 (>=0<=254),C,true,number.boiler_dhw_selected_temperature,number.boiler_dhw_seltemp @@ -1634,7 +1652,7 @@ Logano GB125/KB195i/Logamatic MC110,boiler,133,workm,active time,time (>=0<=1677 Logano GB125/KB195i/Logamatic MC110,boiler,133,nompower,nominal Power,uint8 (>=0<=254),kW,true,number.boiler_nominal_Power,number.boiler_nompower Logano GB125/KB195i/Logamatic MC110,boiler,133,nrgtotal,total energy,uint24 (>=0<=167772),kWh,false,sensor.boiler_total_energy,sensor.boiler_nrgtotal Logano GB125/KB195i/Logamatic MC110,boiler,133,nrgheat,energy heating,uint24 (>=0<=10000000),kWh,true,number.boiler_energy_heating,number.boiler_nrgheat -Logano GB125/KB195i/Logamatic MC110,boiler,133,nrgdhw,energy,uint24 (>=0<=10000000),kWh,true,number.boiler_dhw_energy,number.boiler_dhw_nrgdhw +Logano GB125/KB195i/Logamatic MC110,boiler,133,nrg,energy,uint24 (>=0<=10000000),kWh,true,number.boiler_dhw_energy,number.boiler_dhw_nrg Greenstar 30Ri Compact,boiler,154,reset,reset,cmd [-\|maintenance\|error\|history\|message], ,true,sensor.boiler_reset,sensor.boiler_reset Greenstar 30Ri Compact,boiler,154,heatingoff,force heating off,boolean, ,true,switch.boiler_force_heating_off,switch.boiler_heatingoff Greenstar 30Ri Compact,boiler,154,heatingactive,heating active,boolean, ,false,binary_sensor.boiler_heating_active,binary_sensor.boiler_heatingactive @@ -1667,7 +1685,7 @@ Greenstar 30Ri Compact,boiler,154,boil2hystoff,hysteresis stage 2 off temperatur Greenstar 30Ri Compact,boiler,154,curveon,heatingcurve on,boolean, ,true,switch.boiler_heatingcurve_on,switch.boiler_curveon Greenstar 30Ri Compact,boiler,154,curvebase,heatingcurve base,uint8 (>=20<=90),C,true,number.boiler_heatingcurve_base,number.boiler_curvebase Greenstar 30Ri Compact,boiler,154,curveend,heatingcurve end,uint8 (>=20<=90),C,true,number.boiler_heatingcurve_end,number.boiler_curveend -Greenstar 30Ri Compact,boiler,154,summertemp,summer temperature,uint8 (>=0<=30),C,true,number.boiler_summer_temperature,number.boiler_summertemp +Greenstar 30Ri Compact,boiler,154,summertemp,summer temperature,uint8 (>=0<=45),C,true,number.boiler_summer_temperature,number.boiler_summertemp Greenstar 30Ri Compact,boiler,154,nofrostmode,nofrost mode,boolean, ,true,switch.boiler_nofrost_mode,switch.boiler_nofrostmode Greenstar 30Ri Compact,boiler,154,nofrosttemp,nofrost temperature,uint8 (>=0<=10),C,true,number.boiler_nofrost_temperature,number.boiler_nofrosttemp Greenstar 30Ri Compact,boiler,154,heatingactivated,heating activated,boolean, ,true,switch.boiler_heating_activated,switch.boiler_heatingactivated @@ -1676,6 +1694,7 @@ Greenstar 30Ri Compact,boiler,154,heatingpump,heating pump,boolean, ,false,binar Greenstar 30Ri Compact,boiler,154,pumpmodmax,boiler pump max power,uint8 (>=0<=100),%,true,number.boiler_boiler_pump_max_power,number.boiler_pumpmodmax Greenstar 30Ri Compact,boiler,154,pumpmodmin,boiler pump min power,uint8 (>=0<=100),%,true,number.boiler_boiler_pump_min_power,number.boiler_pumpmodmin Greenstar 30Ri Compact,boiler,154,pumpmode,boiler pump mode,enum [proportional\|deltaP-1\|deltaP-2\|deltaP-3\|deltaP-4], ,true,select.boiler_boiler_pump_mode,select.boiler_pumpmode +Greenstar 30Ri Compact,boiler,154,pumpcharacter,boiler pump characteristic,enum [proportional\|150mbar\|200mbar\|250mbar\|300mbar\|350mbar\|400mbar], ,true,select.boiler_boiler_pump_characteristic,select.boiler_pumpcharacter Greenstar 30Ri Compact,boiler,154,pumpdelay,pump delay,uint8 (>=0<=60),minutes,true,number.boiler_pump_delay,number.boiler_pumpdelay Greenstar 30Ri Compact,boiler,154,setflowtemp,set flow temperature,uint8 (>=0<=254),C,false,sensor.boiler_set_flow_temperature,sensor.boiler_setflowtemp Greenstar 30Ri Compact,boiler,154,setburnpow,burner set power,uint8 (>=0<=100),%,false,sensor.boiler_burner_set_power,sensor.boiler_setburnpow @@ -1697,11 +1716,11 @@ Greenstar 30Ri Compact,boiler,154,maintenancedate,next maintenance date,string, Greenstar 30Ri Compact,boiler,154,emergencyops,emergency operation,boolean, ,true,switch.boiler_emergency_operation,switch.boiler_emergencyops Greenstar 30Ri Compact,boiler,154,emergencytemp,emergency temperature,uint8 (>=15<=70),C,true,number.boiler_emergency_temperature,number.boiler_emergencytemp Greenstar 30Ri Compact,boiler,154,meterheat,meter heating,uint24 (>=0<=1677721),kWh,false,sensor.boiler_meter_heating,sensor.boiler_meterheat -Greenstar 30Ri Compact,boiler,154,meterdhw,meter,uint24 (>=0<=1677721),kWh,false,sensor.boiler_dhw_meter,sensor.boiler_dhw_meterdhw +Greenstar 30Ri Compact,boiler,154,meter,meter,uint24 (>=0<=1677721),kWh,false,sensor.boiler_dhw_meter,sensor.boiler_dhw_meter Greenstar 30Ri Compact,boiler,154,gasmeterheat,gas meter heating,uint24 (>=0<=1677721),kWh,false,sensor.boiler_gas_meter_heating,sensor.boiler_gasmeterheat -Greenstar 30Ri Compact,boiler,154,gasmeterdhw,gas meter,uint24 (>=0<=1677721),kWh,false,sensor.boiler_dhw_gas_meter,sensor.boiler_dhw_gasmeterdhw +Greenstar 30Ri Compact,boiler,154,gasmeter,gas meter,uint24 (>=0<=1677721),kWh,false,sensor.boiler_dhw_gas_meter,sensor.boiler_dhw_gasmeter Greenstar 30Ri Compact,boiler,154,nrgheat2,energy heating 2,uint24 (>=0<=1677721),kWh,false,sensor.boiler_energy_heating_2,sensor.boiler_nrgheat2 -Greenstar 30Ri Compact,boiler,154,nrgdhw2,energy 2,uint24 (>=0<=1677721),kWh,false,sensor.boiler_dhw_energy_2,sensor.boiler_dhw_nrgdhw2 +Greenstar 30Ri Compact,boiler,154,nrg2,energy 2,uint24 (>=0<=1677721),kWh,false,sensor.boiler_dhw_energy_2,sensor.boiler_dhw_nrg2 Greenstar 30Ri Compact,boiler,154,tapactivated,turn on/off,boolean, ,true,switch.boiler_dhw_turn_on/off,switch.boiler_dhw_tapactivated Greenstar 30Ri Compact,boiler,154,settemp,set temperature,uint8 (>=0<=254),C,false,sensor.boiler_dhw_set_temperature,sensor.boiler_dhw_settemp Greenstar 30Ri Compact,boiler,154,seltemp,selected temperature,uint8 (>=0<=254),C,true,number.boiler_dhw_selected_temperature,number.boiler_dhw_seltemp @@ -1745,7 +1764,7 @@ Greenstar 30Ri Compact,boiler,154,workm,active time,time (>=0<=16777213),minutes Greenstar 30Ri Compact,boiler,154,nompower,nominal Power,uint8 (>=0<=254),kW,true,number.boiler_nominal_Power,number.boiler_nompower Greenstar 30Ri Compact,boiler,154,nrgtotal,total energy,uint24 (>=0<=167772),kWh,false,sensor.boiler_total_energy,sensor.boiler_nrgtotal Greenstar 30Ri Compact,boiler,154,nrgheat,energy heating,uint24 (>=0<=10000000),kWh,true,number.boiler_energy_heating,number.boiler_nrgheat -Greenstar 30Ri Compact,boiler,154,nrgdhw,energy,uint24 (>=0<=10000000),kWh,true,number.boiler_dhw_energy,number.boiler_dhw_nrgdhw +Greenstar 30Ri Compact,boiler,154,nrg,energy,uint24 (>=0<=10000000),kWh,true,number.boiler_dhw_energy,number.boiler_dhw_nrg Cerapur Aero,boiler,167,reset,reset,cmd [-\|maintenance\|error\|history\|message], ,true,sensor.boiler_reset,sensor.boiler_reset Cerapur Aero,boiler,167,heatingoff,force heating off,boolean, ,true,switch.boiler_force_heating_off,switch.boiler_heatingoff Cerapur Aero,boiler,167,heatingactive,heating active,boolean, ,false,binary_sensor.boiler_heating_active,binary_sensor.boiler_heatingactive @@ -1778,7 +1797,7 @@ Cerapur Aero,boiler,167,boil2hystoff,hysteresis stage 2 off temperature,int8 (>= Cerapur Aero,boiler,167,curveon,heatingcurve on,boolean, ,true,switch.boiler_heatingcurve_on,switch.boiler_curveon Cerapur Aero,boiler,167,curvebase,heatingcurve base,uint8 (>=20<=90),C,true,number.boiler_heatingcurve_base,number.boiler_curvebase Cerapur Aero,boiler,167,curveend,heatingcurve end,uint8 (>=20<=90),C,true,number.boiler_heatingcurve_end,number.boiler_curveend -Cerapur Aero,boiler,167,summertemp,summer temperature,uint8 (>=0<=30),C,true,number.boiler_summer_temperature,number.boiler_summertemp +Cerapur Aero,boiler,167,summertemp,summer temperature,uint8 (>=0<=45),C,true,number.boiler_summer_temperature,number.boiler_summertemp Cerapur Aero,boiler,167,nofrostmode,nofrost mode,boolean, ,true,switch.boiler_nofrost_mode,switch.boiler_nofrostmode Cerapur Aero,boiler,167,nofrosttemp,nofrost temperature,uint8 (>=0<=10),C,true,number.boiler_nofrost_temperature,number.boiler_nofrosttemp Cerapur Aero,boiler,167,heatingactivated,heating activated,boolean, ,true,switch.boiler_heating_activated,switch.boiler_heatingactivated @@ -1787,6 +1806,7 @@ Cerapur Aero,boiler,167,heatingpump,heating pump,boolean, ,false,binary_sensor.b Cerapur Aero,boiler,167,pumpmodmax,boiler pump max power,uint8 (>=0<=100),%,true,number.boiler_boiler_pump_max_power,number.boiler_pumpmodmax Cerapur Aero,boiler,167,pumpmodmin,boiler pump min power,uint8 (>=0<=100),%,true,number.boiler_boiler_pump_min_power,number.boiler_pumpmodmin Cerapur Aero,boiler,167,pumpmode,boiler pump mode,enum [proportional\|deltaP-1\|deltaP-2\|deltaP-3\|deltaP-4], ,true,select.boiler_boiler_pump_mode,select.boiler_pumpmode +Cerapur Aero,boiler,167,pumpcharacter,boiler pump characteristic,enum [proportional\|150mbar\|200mbar\|250mbar\|300mbar\|350mbar\|400mbar], ,true,select.boiler_boiler_pump_characteristic,select.boiler_pumpcharacter Cerapur Aero,boiler,167,pumpdelay,pump delay,uint8 (>=0<=60),minutes,true,number.boiler_pump_delay,number.boiler_pumpdelay Cerapur Aero,boiler,167,setflowtemp,set flow temperature,uint8 (>=0<=254),C,false,sensor.boiler_set_flow_temperature,sensor.boiler_setflowtemp Cerapur Aero,boiler,167,setburnpow,burner set power,uint8 (>=0<=100),%,false,sensor.boiler_burner_set_power,sensor.boiler_setburnpow @@ -1808,11 +1828,11 @@ Cerapur Aero,boiler,167,maintenancedate,next maintenance date,string, ,true,sens Cerapur Aero,boiler,167,emergencyops,emergency operation,boolean, ,true,switch.boiler_emergency_operation,switch.boiler_emergencyops Cerapur Aero,boiler,167,emergencytemp,emergency temperature,uint8 (>=15<=70),C,true,number.boiler_emergency_temperature,number.boiler_emergencytemp Cerapur Aero,boiler,167,meterheat,meter heating,uint24 (>=0<=1677721),kWh,false,sensor.boiler_meter_heating,sensor.boiler_meterheat -Cerapur Aero,boiler,167,meterdhw,meter,uint24 (>=0<=1677721),kWh,false,sensor.boiler_dhw_meter,sensor.boiler_dhw_meterdhw +Cerapur Aero,boiler,167,meter,meter,uint24 (>=0<=1677721),kWh,false,sensor.boiler_dhw_meter,sensor.boiler_dhw_meter Cerapur Aero,boiler,167,gasmeterheat,gas meter heating,uint24 (>=0<=1677721),kWh,false,sensor.boiler_gas_meter_heating,sensor.boiler_gasmeterheat -Cerapur Aero,boiler,167,gasmeterdhw,gas meter,uint24 (>=0<=1677721),kWh,false,sensor.boiler_dhw_gas_meter,sensor.boiler_dhw_gasmeterdhw +Cerapur Aero,boiler,167,gasmeter,gas meter,uint24 (>=0<=1677721),kWh,false,sensor.boiler_dhw_gas_meter,sensor.boiler_dhw_gasmeter Cerapur Aero,boiler,167,nrgheat2,energy heating 2,uint24 (>=0<=1677721),kWh,false,sensor.boiler_energy_heating_2,sensor.boiler_nrgheat2 -Cerapur Aero,boiler,167,nrgdhw2,energy 2,uint24 (>=0<=1677721),kWh,false,sensor.boiler_dhw_energy_2,sensor.boiler_dhw_nrgdhw2 +Cerapur Aero,boiler,167,nrg2,energy 2,uint24 (>=0<=1677721),kWh,false,sensor.boiler_dhw_energy_2,sensor.boiler_dhw_nrg2 Cerapur Aero,boiler,167,tapactivated,turn on/off,boolean, ,true,switch.boiler_dhw_turn_on/off,switch.boiler_dhw_tapactivated Cerapur Aero,boiler,167,settemp,set temperature,uint8 (>=0<=254),C,false,sensor.boiler_dhw_set_temperature,sensor.boiler_dhw_settemp Cerapur Aero,boiler,167,seltemp,selected temperature,uint8 (>=0<=254),C,true,number.boiler_dhw_selected_temperature,number.boiler_dhw_seltemp @@ -1856,7 +1876,7 @@ Cerapur Aero,boiler,167,workm,active time,time (>=0<=16777213),minutes,false,sen Cerapur Aero,boiler,167,nompower,nominal Power,uint8 (>=0<=254),kW,true,number.boiler_nominal_Power,number.boiler_nompower Cerapur Aero,boiler,167,nrgtotal,total energy,uint24 (>=0<=167772),kWh,false,sensor.boiler_total_energy,sensor.boiler_nrgtotal Cerapur Aero,boiler,167,nrgheat,energy heating,uint24 (>=0<=10000000),kWh,true,number.boiler_energy_heating,number.boiler_nrgheat -Cerapur Aero,boiler,167,nrgdhw,energy,uint24 (>=0<=10000000),kWh,true,number.boiler_dhw_energy,number.boiler_dhw_nrgdhw +Cerapur Aero,boiler,167,nrg,energy,uint24 (>=0<=10000000),kWh,true,number.boiler_dhw_energy,number.boiler_dhw_nrg Hybrid Heatpump,boiler,168,reset,reset,cmd [-\|maintenance\|error\|history\|message], ,true,sensor.boiler_reset,sensor.boiler_reset Hybrid Heatpump,boiler,168,heatingoff,force heating off,boolean, ,true,switch.boiler_force_heating_off,switch.boiler_heatingoff Hybrid Heatpump,boiler,168,heatingactive,heating active,boolean, ,false,binary_sensor.boiler_heating_active,binary_sensor.boiler_heatingactive @@ -1889,7 +1909,7 @@ Hybrid Heatpump,boiler,168,boil2hystoff,hysteresis stage 2 off temperature,int8 Hybrid Heatpump,boiler,168,curveon,heatingcurve on,boolean, ,true,switch.boiler_heatingcurve_on,switch.boiler_curveon Hybrid Heatpump,boiler,168,curvebase,heatingcurve base,uint8 (>=20<=90),C,true,number.boiler_heatingcurve_base,number.boiler_curvebase Hybrid Heatpump,boiler,168,curveend,heatingcurve end,uint8 (>=20<=90),C,true,number.boiler_heatingcurve_end,number.boiler_curveend -Hybrid Heatpump,boiler,168,summertemp,summer temperature,uint8 (>=0<=30),C,true,number.boiler_summer_temperature,number.boiler_summertemp +Hybrid Heatpump,boiler,168,summertemp,summer temperature,uint8 (>=0<=45),C,true,number.boiler_summer_temperature,number.boiler_summertemp Hybrid Heatpump,boiler,168,nofrostmode,nofrost mode,boolean, ,true,switch.boiler_nofrost_mode,switch.boiler_nofrostmode Hybrid Heatpump,boiler,168,nofrosttemp,nofrost temperature,uint8 (>=0<=10),C,true,number.boiler_nofrost_temperature,number.boiler_nofrosttemp Hybrid Heatpump,boiler,168,heatingactivated,heating activated,boolean, ,true,switch.boiler_heating_activated,switch.boiler_heatingactivated @@ -1898,6 +1918,7 @@ Hybrid Heatpump,boiler,168,heatingpump,heating pump,boolean, ,false,binary_senso Hybrid Heatpump,boiler,168,pumpmodmax,boiler pump max power,uint8 (>=0<=100),%,true,number.boiler_boiler_pump_max_power,number.boiler_pumpmodmax Hybrid Heatpump,boiler,168,pumpmodmin,boiler pump min power,uint8 (>=0<=100),%,true,number.boiler_boiler_pump_min_power,number.boiler_pumpmodmin Hybrid Heatpump,boiler,168,pumpmode,boiler pump mode,enum [proportional\|deltaP-1\|deltaP-2\|deltaP-3\|deltaP-4], ,true,select.boiler_boiler_pump_mode,select.boiler_pumpmode +Hybrid Heatpump,boiler,168,pumpcharacter,boiler pump characteristic,enum [proportional\|150mbar\|200mbar\|250mbar\|300mbar\|350mbar\|400mbar], ,true,select.boiler_boiler_pump_characteristic,select.boiler_pumpcharacter Hybrid Heatpump,boiler,168,pumpdelay,pump delay,uint8 (>=0<=60),minutes,true,number.boiler_pump_delay,number.boiler_pumpdelay Hybrid Heatpump,boiler,168,setflowtemp,set flow temperature,uint8 (>=0<=254),C,false,sensor.boiler_set_flow_temperature,sensor.boiler_setflowtemp Hybrid Heatpump,boiler,168,setburnpow,burner set power,uint8 (>=0<=100),%,false,sensor.boiler_burner_set_power,sensor.boiler_setburnpow @@ -1919,11 +1940,11 @@ Hybrid Heatpump,boiler,168,maintenancedate,next maintenance date,string, ,true,s Hybrid Heatpump,boiler,168,emergencyops,emergency operation,boolean, ,true,switch.boiler_emergency_operation,switch.boiler_emergencyops Hybrid Heatpump,boiler,168,emergencytemp,emergency temperature,uint8 (>=15<=70),C,true,number.boiler_emergency_temperature,number.boiler_emergencytemp Hybrid Heatpump,boiler,168,meterheat,meter heating,uint24 (>=0<=1677721),kWh,false,sensor.boiler_meter_heating,sensor.boiler_meterheat -Hybrid Heatpump,boiler,168,meterdhw,meter,uint24 (>=0<=1677721),kWh,false,sensor.boiler_dhw_meter,sensor.boiler_dhw_meterdhw +Hybrid Heatpump,boiler,168,meter,meter,uint24 (>=0<=1677721),kWh,false,sensor.boiler_dhw_meter,sensor.boiler_dhw_meter Hybrid Heatpump,boiler,168,gasmeterheat,gas meter heating,uint24 (>=0<=1677721),kWh,false,sensor.boiler_gas_meter_heating,sensor.boiler_gasmeterheat -Hybrid Heatpump,boiler,168,gasmeterdhw,gas meter,uint24 (>=0<=1677721),kWh,false,sensor.boiler_dhw_gas_meter,sensor.boiler_dhw_gasmeterdhw +Hybrid Heatpump,boiler,168,gasmeter,gas meter,uint24 (>=0<=1677721),kWh,false,sensor.boiler_dhw_gas_meter,sensor.boiler_dhw_gasmeter Hybrid Heatpump,boiler,168,nrgheat2,energy heating 2,uint24 (>=0<=1677721),kWh,false,sensor.boiler_energy_heating_2,sensor.boiler_nrgheat2 -Hybrid Heatpump,boiler,168,nrgdhw2,energy 2,uint24 (>=0<=1677721),kWh,false,sensor.boiler_dhw_energy_2,sensor.boiler_dhw_nrgdhw2 +Hybrid Heatpump,boiler,168,nrg2,energy 2,uint24 (>=0<=1677721),kWh,false,sensor.boiler_dhw_energy_2,sensor.boiler_dhw_nrg2 Hybrid Heatpump,boiler,168,tapactivated,turn on/off,boolean, ,true,switch.boiler_dhw_turn_on/off,switch.boiler_dhw_tapactivated Hybrid Heatpump,boiler,168,settemp,set temperature,uint8 (>=0<=254),C,false,sensor.boiler_dhw_set_temperature,sensor.boiler_dhw_settemp Hybrid Heatpump,boiler,168,seltemp,selected temperature,uint8 (>=0<=254),C,true,number.boiler_dhw_selected_temperature,number.boiler_dhw_seltemp @@ -1967,7 +1988,7 @@ Hybrid Heatpump,boiler,168,workm,active time,time (>=0<=16777213),minutes,false, Hybrid Heatpump,boiler,168,nompower,nominal Power,uint8 (>=0<=254),kW,true,number.boiler_nominal_Power,number.boiler_nompower Hybrid Heatpump,boiler,168,nrgtotal,total energy,uint24 (>=0<=167772),kWh,false,sensor.boiler_total_energy,sensor.boiler_nrgtotal Hybrid Heatpump,boiler,168,nrgheat,energy heating,uint24 (>=0<=10000000),kWh,true,number.boiler_energy_heating,number.boiler_nrgheat -Hybrid Heatpump,boiler,168,nrgdhw,energy,uint24 (>=0<=10000000),kWh,true,number.boiler_dhw_energy,number.boiler_dhw_nrgdhw +Hybrid Heatpump,boiler,168,nrg,energy,uint24 (>=0<=10000000),kWh,true,number.boiler_dhw_energy,number.boiler_dhw_nrg Logano GB212,boiler,170,reset,reset,cmd [-\|maintenance\|error\|history\|message], ,true,sensor.boiler_reset,sensor.boiler_reset Logano GB212,boiler,170,heatingoff,force heating off,boolean, ,true,switch.boiler_force_heating_off,switch.boiler_heatingoff Logano GB212,boiler,170,heatingactive,heating active,boolean, ,false,binary_sensor.boiler_heating_active,binary_sensor.boiler_heatingactive @@ -2000,7 +2021,7 @@ Logano GB212,boiler,170,boil2hystoff,hysteresis stage 2 off temperature,int8 (>= Logano GB212,boiler,170,curveon,heatingcurve on,boolean, ,true,switch.boiler_heatingcurve_on,switch.boiler_curveon Logano GB212,boiler,170,curvebase,heatingcurve base,uint8 (>=20<=90),C,true,number.boiler_heatingcurve_base,number.boiler_curvebase Logano GB212,boiler,170,curveend,heatingcurve end,uint8 (>=20<=90),C,true,number.boiler_heatingcurve_end,number.boiler_curveend -Logano GB212,boiler,170,summertemp,summer temperature,uint8 (>=0<=30),C,true,number.boiler_summer_temperature,number.boiler_summertemp +Logano GB212,boiler,170,summertemp,summer temperature,uint8 (>=0<=45),C,true,number.boiler_summer_temperature,number.boiler_summertemp Logano GB212,boiler,170,nofrostmode,nofrost mode,boolean, ,true,switch.boiler_nofrost_mode,switch.boiler_nofrostmode Logano GB212,boiler,170,nofrosttemp,nofrost temperature,uint8 (>=0<=10),C,true,number.boiler_nofrost_temperature,number.boiler_nofrosttemp Logano GB212,boiler,170,heatingactivated,heating activated,boolean, ,true,switch.boiler_heating_activated,switch.boiler_heatingactivated @@ -2009,6 +2030,7 @@ Logano GB212,boiler,170,heatingpump,heating pump,boolean, ,false,binary_sensor.b Logano GB212,boiler,170,pumpmodmax,boiler pump max power,uint8 (>=0<=100),%,true,number.boiler_boiler_pump_max_power,number.boiler_pumpmodmax Logano GB212,boiler,170,pumpmodmin,boiler pump min power,uint8 (>=0<=100),%,true,number.boiler_boiler_pump_min_power,number.boiler_pumpmodmin Logano GB212,boiler,170,pumpmode,boiler pump mode,enum [proportional\|deltaP-1\|deltaP-2\|deltaP-3\|deltaP-4], ,true,select.boiler_boiler_pump_mode,select.boiler_pumpmode +Logano GB212,boiler,170,pumpcharacter,boiler pump characteristic,enum [proportional\|150mbar\|200mbar\|250mbar\|300mbar\|350mbar\|400mbar], ,true,select.boiler_boiler_pump_characteristic,select.boiler_pumpcharacter Logano GB212,boiler,170,pumpdelay,pump delay,uint8 (>=0<=60),minutes,true,number.boiler_pump_delay,number.boiler_pumpdelay Logano GB212,boiler,170,setflowtemp,set flow temperature,uint8 (>=0<=254),C,false,sensor.boiler_set_flow_temperature,sensor.boiler_setflowtemp Logano GB212,boiler,170,setburnpow,burner set power,uint8 (>=0<=100),%,false,sensor.boiler_burner_set_power,sensor.boiler_setburnpow @@ -2030,11 +2052,11 @@ Logano GB212,boiler,170,maintenancedate,next maintenance date,string, ,true,sens Logano GB212,boiler,170,emergencyops,emergency operation,boolean, ,true,switch.boiler_emergency_operation,switch.boiler_emergencyops Logano GB212,boiler,170,emergencytemp,emergency temperature,uint8 (>=15<=70),C,true,number.boiler_emergency_temperature,number.boiler_emergencytemp Logano GB212,boiler,170,meterheat,meter heating,uint24 (>=0<=1677721),kWh,false,sensor.boiler_meter_heating,sensor.boiler_meterheat -Logano GB212,boiler,170,meterdhw,meter,uint24 (>=0<=1677721),kWh,false,sensor.boiler_dhw_meter,sensor.boiler_dhw_meterdhw +Logano GB212,boiler,170,meter,meter,uint24 (>=0<=1677721),kWh,false,sensor.boiler_dhw_meter,sensor.boiler_dhw_meter Logano GB212,boiler,170,gasmeterheat,gas meter heating,uint24 (>=0<=1677721),kWh,false,sensor.boiler_gas_meter_heating,sensor.boiler_gasmeterheat -Logano GB212,boiler,170,gasmeterdhw,gas meter,uint24 (>=0<=1677721),kWh,false,sensor.boiler_dhw_gas_meter,sensor.boiler_dhw_gasmeterdhw +Logano GB212,boiler,170,gasmeter,gas meter,uint24 (>=0<=1677721),kWh,false,sensor.boiler_dhw_gas_meter,sensor.boiler_dhw_gasmeter Logano GB212,boiler,170,nrgheat2,energy heating 2,uint24 (>=0<=1677721),kWh,false,sensor.boiler_energy_heating_2,sensor.boiler_nrgheat2 -Logano GB212,boiler,170,nrgdhw2,energy 2,uint24 (>=0<=1677721),kWh,false,sensor.boiler_dhw_energy_2,sensor.boiler_dhw_nrgdhw2 +Logano GB212,boiler,170,nrg2,energy 2,uint24 (>=0<=1677721),kWh,false,sensor.boiler_dhw_energy_2,sensor.boiler_dhw_nrg2 Logano GB212,boiler,170,tapactivated,turn on/off,boolean, ,true,switch.boiler_dhw_turn_on/off,switch.boiler_dhw_tapactivated Logano GB212,boiler,170,settemp,set temperature,uint8 (>=0<=254),C,false,sensor.boiler_dhw_set_temperature,sensor.boiler_dhw_settemp Logano GB212,boiler,170,seltemp,selected temperature,uint8 (>=0<=254),C,true,number.boiler_dhw_selected_temperature,number.boiler_dhw_seltemp @@ -2078,7 +2100,7 @@ Logano GB212,boiler,170,workm,active time,time (>=0<=16777213),minutes,false,sen Logano GB212,boiler,170,nompower,nominal Power,uint8 (>=0<=254),kW,true,number.boiler_nominal_Power,number.boiler_nompower Logano GB212,boiler,170,nrgtotal,total energy,uint24 (>=0<=167772),kWh,false,sensor.boiler_total_energy,sensor.boiler_nrgtotal Logano GB212,boiler,170,nrgheat,energy heating,uint24 (>=0<=10000000),kWh,true,number.boiler_energy_heating,number.boiler_nrgheat -Logano GB212,boiler,170,nrgdhw,energy,uint24 (>=0<=10000000),kWh,true,number.boiler_dhw_energy,number.boiler_dhw_nrgdhw +Logano GB212,boiler,170,nrg,energy,uint24 (>=0<=10000000),kWh,true,number.boiler_dhw_energy,number.boiler_dhw_nrg Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,reset,reset,cmd [-\|maintenance\|error\|history\|message], ,true,sensor.boiler_reset,sensor.boiler_reset Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,heatingoff,force heating off,boolean, ,true,switch.boiler_force_heating_off,switch.boiler_heatingoff Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,heatingactive,heating active,boolean, ,false,binary_sensor.boiler_heating_active,binary_sensor.boiler_heatingactive @@ -2098,6 +2120,7 @@ Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,bo Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,pumpmodmax,boiler pump max power,uint8 (>=0<=100),%,true,number.boiler_boiler_pump_max_power,number.boiler_pumpmodmax Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,pumpmodmin,boiler pump min power,uint8 (>=0<=100),%,true,number.boiler_boiler_pump_min_power,number.boiler_pumpmodmin Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,pumpmode,boiler pump mode,enum [proportional\|deltaP-1\|deltaP-2\|deltaP-3\|deltaP-4], ,true,select.boiler_boiler_pump_mode,select.boiler_pumpmode +Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,pumpcharacter,boiler pump characteristic,enum [proportional\|150mbar\|200mbar\|250mbar\|300mbar\|350mbar\|400mbar], ,true,select.boiler_boiler_pump_characteristic,select.boiler_pumpcharacter Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,pumpdelay,pump delay,uint8 (>=0<=60),minutes,true,number.boiler_pump_delay,number.boiler_pumpdelay Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,setflowtemp,set flow temperature,uint8 (>=0<=254),C,false,sensor.boiler_set_flow_temperature,sensor.boiler_setflowtemp Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,setburnpow,burner set power,uint8 (>=0<=100),%,false,sensor.boiler_burner_set_power,sensor.boiler_setburnpow @@ -2119,18 +2142,18 @@ Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,bo Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,emergencyops,emergency operation,boolean, ,true,switch.boiler_emergency_operation,switch.boiler_emergencyops Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,emergencytemp,emergency temperature,uint8 (>=15<=70),C,true,number.boiler_emergency_temperature,number.boiler_emergencytemp Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,nrgtotal,total energy,uint24 (>=0<=167772),kWh,false,sensor.boiler_total_energy,sensor.boiler_nrgtotal -Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,nrgdhw,energy,uint24 (>=0<=167772),kWh,false,sensor.boiler_dhw_energy,sensor.boiler_dhw_nrgdhw +Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,nrg,energy,uint24 (>=0<=167772),kWh,false,sensor.boiler_dhw_energy,sensor.boiler_dhw_nrg Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,nrgheat,energy heating,uint24 (>=0<=167772),kWh,false,sensor.boiler_energy_heating,sensor.boiler_nrgheat Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,metertotal,meter total,uint24 (>=0<=167772),kWh,false,sensor.boiler_meter_total,sensor.boiler_metertotal Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,metercomp,meter compressor,uint24 (>=0<=167772),kWh,false,sensor.boiler_meter_compressor,sensor.boiler_metercomp Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,metereheat,meter e-heater,uint24 (>=0<=167772),kWh,false,sensor.boiler_meter_e-heater,sensor.boiler_metereheat Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,meterheat,meter heating,uint24 (>=0<=167772),kWh,false,sensor.boiler_meter_heating,sensor.boiler_meterheat -Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,meterdhw,meter,uint24 (>=0<=167772),kWh,false,sensor.boiler_dhw_meter,sensor.boiler_dhw_meterdhw +Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,meter,meter,uint24 (>=0<=167772),kWh,false,sensor.boiler_dhw_meter,sensor.boiler_dhw_meter Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,uptimetotal,heatpump total uptime,time (>=0<=279620),minutes,false,sensor.boiler_heatpump_total_uptime,sensor.boiler_uptimetotal Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,uptimecontrol,total operating time heat,time (>=0<=279620),minutes,false,sensor.boiler_total_operating_time_heat,sensor.boiler_uptimecontrol Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,uptimecompheating,operating time compressor heating,time (>=0<=279620),minutes,false,sensor.boiler_operating_time_compressor_heating,sensor.boiler_uptimecompheating Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,uptimecompcooling,operating time compressor cooling,time (>=0<=279620),minutes,false,sensor.boiler_operating_time_compressor_cooling,sensor.boiler_uptimecompcooling -Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,uptimecompdhw,operating time compressor,time (>=0<=279620),minutes,false,sensor.boiler_dhw_operating_time_compressor,sensor.boiler_dhw_uptimecompdhw +Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,uptimecomp,operating time compressor,time (>=0<=279620),minutes,false,sensor.boiler_dhw_operating_time_compressor,sensor.boiler_dhw_uptimecomp Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,uptimecomppool,operating time compressor pool,time (>=0<=279620),minutes,false,sensor.boiler_operating_time_compressor_pool,sensor.boiler_uptimecomppool Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,totalcompstarts,total compressor control starts,uint24 (>=0<=16777213), ,false,sensor.boiler_total_compressor_control_starts,sensor.boiler_totalcompstarts Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,heatingstarts,heating control starts,uint24 (>=0<=16777213), ,false,sensor.boiler_heating_control_starts,sensor.boiler_heatingstarts @@ -2140,16 +2163,16 @@ Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,bo Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,nrgconstotal,total energy consumption,uint24 (>=0<=16777213),kWh,false,sensor.boiler_total_energy_consumption,sensor.boiler_nrgconstotal Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,nrgconscomptotal,total energy consumption compressor,uint24 (>=0<=16777213),kWh,false,sensor.boiler_total_energy_consumption_compressor,sensor.boiler_nrgconscomptotal Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,nrgconscompheating,energy consumption compressor heating,uint24 (>=0<=16777213),kWh,false,sensor.boiler_energy_consumption_compressor_heating,sensor.boiler_nrgconscompheating -Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,nrgconscompdhw,energy consumption compressor,uint24 (>=0<=16777213),kWh,false,sensor.boiler_dhw_energy_consumption_compressor,sensor.boiler_dhw_nrgconscompdhw +Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,nrgconscomp,energy consumption compressor,uint24 (>=0<=16777213),kWh,false,sensor.boiler_dhw_energy_consumption_compressor,sensor.boiler_dhw_nrgconscomp Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,nrgconscompcooling,energy consumption compressor cooling,uint24 (>=0<=16777213),kWh,false,sensor.boiler_energy_consumption_compressor_cooling,sensor.boiler_nrgconscompcooling Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,nrgconscomppool,energy consumption compressor pool,uint24 (>=0<=16777213),kWh,false,sensor.boiler_energy_consumption_compressor_pool,sensor.boiler_nrgconscomppool Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,auxelecheatnrgconstotal,total aux elec. heater energy consumption,uint24 (>=0<=16777213),kWh,false,sensor.boiler_total_aux_elec._heater_energy_consumption,sensor.boiler_auxelecheatnrgconstotal Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,auxelecheatnrgconsheating,aux elec. heater energy consumption heating,uint24 (>=0<=16777213),kWh,false,sensor.boiler_aux_elec._heater_energy_consumption_heating,sensor.boiler_auxelecheatnrgconsheating -Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,auxelecheatnrgconsdhw,aux elec. heater energy consumption,uint24 (>=0<=16777213),kWh,false,sensor.boiler_dhw_aux_elec._heater_energy_consumption,sensor.boiler_dhw_auxelecheatnrgconsdhw +Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,auxelecheatnrgcons,aux elec. heater energy consumption,uint24 (>=0<=16777213),kWh,false,sensor.boiler_dhw_aux_elec._heater_energy_consumption,sensor.boiler_dhw_auxelecheatnrgcons Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,auxelecheatnrgconspool,aux elec. heater energy consumption pool,uint24 (>=0<=16777213),kWh,false,sensor.boiler_aux_elec._heater_energy_consumption_pool,sensor.boiler_auxelecheatnrgconspool Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,nrgsupptotal,total energy supplied,uint24 (>=0<=16777213),kWh,false,sensor.boiler_total_energy_supplied,sensor.boiler_nrgsupptotal Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,nrgsuppheating,total energy supplied heating,uint24 (>=0<=16777213),kWh,false,sensor.boiler_total_energy_supplied_heating,sensor.boiler_nrgsuppheating -Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,nrgsuppdhw,total energy warm supplied,uint24 (>=0<=16777213),kWh,false,sensor.boiler_dhw_total_energy_warm_supplied,sensor.boiler_dhw_nrgsuppdhw +Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,nrgsupp,total energy warm supplied,uint24 (>=0<=16777213),kWh,false,sensor.boiler_dhw_total_energy_warm_supplied,sensor.boiler_dhw_nrgsupp Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,nrgsuppcooling,total energy supplied cooling,uint24 (>=0<=16777213),kWh,false,sensor.boiler_total_energy_supplied_cooling,sensor.boiler_nrgsuppcooling Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,nrgsupppool,total energy supplied pool,uint24 (>=0<=16777213),kWh,false,sensor.boiler_total_energy_supplied_pool,sensor.boiler_nrgsupppool Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,hppower,compressor power output,uint8 (>=0<=25),kW,false,sensor.boiler_compressor_power_output,sensor.boiler_hppower @@ -2179,13 +2202,17 @@ Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,bo Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,hptw1,reservoir temp (TW1),int16 (>=-3199<=3199),C,false,sensor.boiler_reservoir_temp_(TW1),sensor.boiler_hptw1 Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,poolsettemp,pool set temperature,uint8 (>=0<=127),C,true,number.boiler_pool_set_temperature,number.boiler_poolsettemp Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,hp4way,4-way valve (VR4),enum [cooling & defrost\|heating & dhw], ,false,sensor.boiler_4-way_valve_(VR4),sensor.boiler_hp4way +Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,hpin1,input 1 state,boolean, ,false,binary_sensor.boiler_input_1_state,binary_sensor.boiler_hpin1 Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,hpin1opt,input 1 options,string, ,true,sensor.boiler_input_1_options,sensor.boiler_hpin1opt +Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,hpin2,input 2 state,boolean, ,false,binary_sensor.boiler_input_2_state,binary_sensor.boiler_hpin2 Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,hpin2opt,input 2 options,string, ,true,sensor.boiler_input_2_options,sensor.boiler_hpin2opt +Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,hpin3,input 3 state,boolean, ,false,binary_sensor.boiler_input_3_state,binary_sensor.boiler_hpin3 Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,hpin3opt,input 3 options,string, ,true,sensor.boiler_input_3_options,sensor.boiler_hpin3opt +Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,hpin4,input 4 state,boolean, ,false,binary_sensor.boiler_input_4_state,binary_sensor.boiler_hpin4 Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,hpin4opt,input 4 options,string, ,true,sensor.boiler_input_4_options,sensor.boiler_hpin4opt Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,maxheatcomp,heat limit compressor,enum [0 kW\|2 kW\|3 kW\|4 kW\|6 kW\|9 kW], ,true,select.boiler_heat_limit_compressor,select.boiler_maxheatcomp Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,maxheatheat,heat limit heating,enum [0 kW\|2 kW\|3 kW\|4 kW\|6 kW\|9 kW], ,true,select.boiler_heat_limit_heating,select.boiler_maxheatheat -Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,maxheatdhw,heat limit,enum [0 kW\|2 kW\|3 kW\|4 kW\|6 kW\|9 kW], ,true,select.boiler_dhw_heat_limit,select.boiler_dhw_maxheatdhw +Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,maxheat,heat limit,enum [0 kW\|2 kW\|3 kW\|4 kW\|6 kW\|9 kW], ,true,select.boiler_dhw_heat_limit,select.boiler_dhw_maxheat Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,mandefrost,manual defrost,boolean, ,true,switch.boiler_manual_defrost,switch.boiler_mandefrost Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,pvcooling,cooling only with PV,boolean, ,true,switch.boiler_cooling_only_with_PV,switch.boiler_pvcooling Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,auxheateronly,aux heater only,boolean, ,true,switch.boiler_aux_heater_only,switch.boiler_auxheateronly @@ -2218,10 +2245,10 @@ Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,bo Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,hpea0,condensate reservoir heating (EA0),boolean, ,false,binary_sensor.boiler_condensate_reservoir_heating_(EA0),binary_sensor.boiler_hpea0 Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,hppumpmode,primary heatpump mode,enum [auto\|continuous], ,true,select.boiler_primary_heatpump_mode,select.boiler_hppumpmode Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,fan,fan,uint8 (>=20<=100),%,true,number.boiler_fan,number.boiler_fan -Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,shutdown,shutdown,boolean, ,true,switch.boiler_shutdown,switch.boiler_shutdown +Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,shutdown,shutdown,cmd [off\|on], ,true,sensor.boiler_shutdown,sensor.boiler_shutdown Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,alternatingop,alternating operation,boolean, ,true,switch.boiler_dhw_alternating_operation,switch.boiler_dhw_alternatingop Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,altopprioheat,prioritise heating during dhw,uint8 (>=20<=120),minutes,true,number.boiler_dhw_prioritise_heating_during_dhw,number.boiler_dhw_altopprioheat -Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,altoppriodhw,prioritise dhw during heating,uint8 (>=30<=120),minutes,true,number.boiler_dhw_prioritise_dhw_during_heating,number.boiler_dhw_altoppriodhw +Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,altopprio,prioritise dhw during heating,uint8 (>=30<=120),minutes,true,number.boiler_dhw_prioritise_dhw_during_heating,number.boiler_dhw_altopprio Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,comfoff,comfort switch off,uint8 (>=15<=65),C,true,number.boiler_dhw_comfort_switch_off,number.boiler_dhw_comfoff Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,ecooff,eco switch off,uint8 (>=15<=65),C,true,number.boiler_dhw_eco_switch_off,number.boiler_dhw_ecooff Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,ecoplusoff,eco+ switch off,uint8 (>=48<=63),C,true,number.boiler_dhw_eco+_switch_off,number.boiler_dhw_ecoplusoff @@ -2231,7 +2258,7 @@ Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,bo Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,comfstop,comfort stop temp,uint8 (>=0<=254),C,true,number.boiler_dhw_comfort_stop_temp,number.boiler_dhw_comfstop Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,ecostop,eco stop temp,uint8 (>=0<=254),C,true,number.boiler_dhw_eco_stop_temp,number.boiler_dhw_ecostop Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,ecoplusstop,eco+ stop temp,uint8 (>=0<=254),C,true,number.boiler_dhw_eco+_stop_temp,number.boiler_dhw_ecoplusstop -Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,hpcircpumpdhw,circulation pump available during dhw,boolean, ,true,switch.boiler_dhw_circulation_pump_available_during_dhw,switch.boiler_dhw_hpcircpumpdhw +Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,hpcircpump,circulation pump available during dhw,boolean, ,true,switch.boiler_dhw_circulation_pump_available_during_dhw,switch.boiler_dhw_hpcircpump Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,tapactivated,turn on/off,boolean, ,true,switch.boiler_dhw_turn_on/off,switch.boiler_dhw_tapactivated Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,settemp,set temperature,uint8 (>=0<=254),C,false,sensor.boiler_dhw_set_temperature,sensor.boiler_dhw_settemp Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i,boiler,172,seltemp,selected temperature,uint8 (>=0<=254),C,true,number.boiler_dhw_selected_temperature,number.boiler_dhw_seltemp @@ -2291,6 +2318,7 @@ Geo 5xx,boiler,173,heatingpump,heating pump,boolean, ,false,binary_sensor.boiler Geo 5xx,boiler,173,pumpmodmax,boiler pump max power,uint8 (>=0<=100),%,true,number.boiler_boiler_pump_max_power,number.boiler_pumpmodmax Geo 5xx,boiler,173,pumpmodmin,boiler pump min power,uint8 (>=0<=100),%,true,number.boiler_boiler_pump_min_power,number.boiler_pumpmodmin Geo 5xx,boiler,173,pumpmode,boiler pump mode,enum [proportional\|deltaP-1\|deltaP-2\|deltaP-3\|deltaP-4], ,true,select.boiler_boiler_pump_mode,select.boiler_pumpmode +Geo 5xx,boiler,173,pumpcharacter,boiler pump characteristic,enum [proportional\|150mbar\|200mbar\|250mbar\|300mbar\|350mbar\|400mbar], ,true,select.boiler_boiler_pump_characteristic,select.boiler_pumpcharacter Geo 5xx,boiler,173,pumpdelay,pump delay,uint8 (>=0<=60),minutes,true,number.boiler_pump_delay,number.boiler_pumpdelay Geo 5xx,boiler,173,setflowtemp,set flow temperature,uint8 (>=0<=254),C,false,sensor.boiler_set_flow_temperature,sensor.boiler_setflowtemp Geo 5xx,boiler,173,setburnpow,burner set power,uint8 (>=0<=100),%,false,sensor.boiler_burner_set_power,sensor.boiler_setburnpow @@ -2312,18 +2340,18 @@ Geo 5xx,boiler,173,maintenancedate,next maintenance date,string, ,true,sensor.bo Geo 5xx,boiler,173,emergencyops,emergency operation,boolean, ,true,switch.boiler_emergency_operation,switch.boiler_emergencyops Geo 5xx,boiler,173,emergencytemp,emergency temperature,uint8 (>=15<=70),C,true,number.boiler_emergency_temperature,number.boiler_emergencytemp Geo 5xx,boiler,173,nrgtotal,total energy,uint24 (>=0<=167772),kWh,false,sensor.boiler_total_energy,sensor.boiler_nrgtotal -Geo 5xx,boiler,173,nrgdhw,energy,uint24 (>=0<=167772),kWh,false,sensor.boiler_dhw_energy,sensor.boiler_dhw_nrgdhw +Geo 5xx,boiler,173,nrg,energy,uint24 (>=0<=167772),kWh,false,sensor.boiler_dhw_energy,sensor.boiler_dhw_nrg Geo 5xx,boiler,173,nrgheat,energy heating,uint24 (>=0<=167772),kWh,false,sensor.boiler_energy_heating,sensor.boiler_nrgheat Geo 5xx,boiler,173,metertotal,meter total,uint24 (>=0<=167772),kWh,false,sensor.boiler_meter_total,sensor.boiler_metertotal Geo 5xx,boiler,173,metercomp,meter compressor,uint24 (>=0<=167772),kWh,false,sensor.boiler_meter_compressor,sensor.boiler_metercomp Geo 5xx,boiler,173,metereheat,meter e-heater,uint24 (>=0<=167772),kWh,false,sensor.boiler_meter_e-heater,sensor.boiler_metereheat Geo 5xx,boiler,173,meterheat,meter heating,uint24 (>=0<=167772),kWh,false,sensor.boiler_meter_heating,sensor.boiler_meterheat -Geo 5xx,boiler,173,meterdhw,meter,uint24 (>=0<=167772),kWh,false,sensor.boiler_dhw_meter,sensor.boiler_dhw_meterdhw +Geo 5xx,boiler,173,meter,meter,uint24 (>=0<=167772),kWh,false,sensor.boiler_dhw_meter,sensor.boiler_dhw_meter Geo 5xx,boiler,173,uptimetotal,heatpump total uptime,time (>=0<=279620),minutes,false,sensor.boiler_heatpump_total_uptime,sensor.boiler_uptimetotal Geo 5xx,boiler,173,uptimecontrol,total operating time heat,time (>=0<=279620),minutes,false,sensor.boiler_total_operating_time_heat,sensor.boiler_uptimecontrol Geo 5xx,boiler,173,uptimecompheating,operating time compressor heating,time (>=0<=279620),minutes,false,sensor.boiler_operating_time_compressor_heating,sensor.boiler_uptimecompheating Geo 5xx,boiler,173,uptimecompcooling,operating time compressor cooling,time (>=0<=279620),minutes,false,sensor.boiler_operating_time_compressor_cooling,sensor.boiler_uptimecompcooling -Geo 5xx,boiler,173,uptimecompdhw,operating time compressor,time (>=0<=279620),minutes,false,sensor.boiler_dhw_operating_time_compressor,sensor.boiler_dhw_uptimecompdhw +Geo 5xx,boiler,173,uptimecomp,operating time compressor,time (>=0<=279620),minutes,false,sensor.boiler_dhw_operating_time_compressor,sensor.boiler_dhw_uptimecomp Geo 5xx,boiler,173,uptimecomppool,operating time compressor pool,time (>=0<=279620),minutes,false,sensor.boiler_operating_time_compressor_pool,sensor.boiler_uptimecomppool Geo 5xx,boiler,173,totalcompstarts,total compressor control starts,uint24 (>=0<=16777213), ,false,sensor.boiler_total_compressor_control_starts,sensor.boiler_totalcompstarts Geo 5xx,boiler,173,heatingstarts,heating control starts,uint24 (>=0<=16777213), ,false,sensor.boiler_heating_control_starts,sensor.boiler_heatingstarts @@ -2333,16 +2361,16 @@ Geo 5xx,boiler,173,poolstarts,pool control starts,uint24 (>=0<=16777213), ,false Geo 5xx,boiler,173,nrgconstotal,total energy consumption,uint24 (>=0<=16777213),kWh,false,sensor.boiler_total_energy_consumption,sensor.boiler_nrgconstotal Geo 5xx,boiler,173,nrgconscomptotal,total energy consumption compressor,uint24 (>=0<=16777213),kWh,false,sensor.boiler_total_energy_consumption_compressor,sensor.boiler_nrgconscomptotal Geo 5xx,boiler,173,nrgconscompheating,energy consumption compressor heating,uint24 (>=0<=16777213),kWh,false,sensor.boiler_energy_consumption_compressor_heating,sensor.boiler_nrgconscompheating -Geo 5xx,boiler,173,nrgconscompdhw,energy consumption compressor,uint24 (>=0<=16777213),kWh,false,sensor.boiler_dhw_energy_consumption_compressor,sensor.boiler_dhw_nrgconscompdhw +Geo 5xx,boiler,173,nrgconscomp,energy consumption compressor,uint24 (>=0<=16777213),kWh,false,sensor.boiler_dhw_energy_consumption_compressor,sensor.boiler_dhw_nrgconscomp Geo 5xx,boiler,173,nrgconscompcooling,energy consumption compressor cooling,uint24 (>=0<=16777213),kWh,false,sensor.boiler_energy_consumption_compressor_cooling,sensor.boiler_nrgconscompcooling Geo 5xx,boiler,173,nrgconscomppool,energy consumption compressor pool,uint24 (>=0<=16777213),kWh,false,sensor.boiler_energy_consumption_compressor_pool,sensor.boiler_nrgconscomppool Geo 5xx,boiler,173,auxelecheatnrgconstotal,total aux elec. heater energy consumption,uint24 (>=0<=16777213),kWh,false,sensor.boiler_total_aux_elec._heater_energy_consumption,sensor.boiler_auxelecheatnrgconstotal Geo 5xx,boiler,173,auxelecheatnrgconsheating,aux elec. heater energy consumption heating,uint24 (>=0<=16777213),kWh,false,sensor.boiler_aux_elec._heater_energy_consumption_heating,sensor.boiler_auxelecheatnrgconsheating -Geo 5xx,boiler,173,auxelecheatnrgconsdhw,aux elec. heater energy consumption,uint24 (>=0<=16777213),kWh,false,sensor.boiler_dhw_aux_elec._heater_energy_consumption,sensor.boiler_dhw_auxelecheatnrgconsdhw +Geo 5xx,boiler,173,auxelecheatnrgcons,aux elec. heater energy consumption,uint24 (>=0<=16777213),kWh,false,sensor.boiler_dhw_aux_elec._heater_energy_consumption,sensor.boiler_dhw_auxelecheatnrgcons Geo 5xx,boiler,173,auxelecheatnrgconspool,aux elec. heater energy consumption pool,uint24 (>=0<=16777213),kWh,false,sensor.boiler_aux_elec._heater_energy_consumption_pool,sensor.boiler_auxelecheatnrgconspool Geo 5xx,boiler,173,nrgsupptotal,total energy supplied,uint24 (>=0<=16777213),kWh,false,sensor.boiler_total_energy_supplied,sensor.boiler_nrgsupptotal Geo 5xx,boiler,173,nrgsuppheating,total energy supplied heating,uint24 (>=0<=16777213),kWh,false,sensor.boiler_total_energy_supplied_heating,sensor.boiler_nrgsuppheating -Geo 5xx,boiler,173,nrgsuppdhw,total energy warm supplied,uint24 (>=0<=16777213),kWh,false,sensor.boiler_dhw_total_energy_warm_supplied,sensor.boiler_dhw_nrgsuppdhw +Geo 5xx,boiler,173,nrgsupp,total energy warm supplied,uint24 (>=0<=16777213),kWh,false,sensor.boiler_dhw_total_energy_warm_supplied,sensor.boiler_dhw_nrgsupp Geo 5xx,boiler,173,nrgsuppcooling,total energy supplied cooling,uint24 (>=0<=16777213),kWh,false,sensor.boiler_total_energy_supplied_cooling,sensor.boiler_nrgsuppcooling Geo 5xx,boiler,173,nrgsupppool,total energy supplied pool,uint24 (>=0<=16777213),kWh,false,sensor.boiler_total_energy_supplied_pool,sensor.boiler_nrgsupppool Geo 5xx,boiler,173,hppower,compressor power output,uint8 (>=0<=25),kW,false,sensor.boiler_compressor_power_output,sensor.boiler_hppower @@ -2372,13 +2400,17 @@ Geo 5xx,boiler,173,hpta4,drain pan temp (TA4),int16 (>=-3199<=3199),C,false,sens Geo 5xx,boiler,173,hptw1,reservoir temp (TW1),int16 (>=-3199<=3199),C,false,sensor.boiler_reservoir_temp_(TW1),sensor.boiler_hptw1 Geo 5xx,boiler,173,poolsettemp,pool set temperature,uint8 (>=0<=127),C,true,number.boiler_pool_set_temperature,number.boiler_poolsettemp Geo 5xx,boiler,173,hp4way,4-way valve (VR4),enum [cooling & defrost\|heating & dhw], ,false,sensor.boiler_4-way_valve_(VR4),sensor.boiler_hp4way +Geo 5xx,boiler,173,hpin1,input 1 state,boolean, ,false,binary_sensor.boiler_input_1_state,binary_sensor.boiler_hpin1 Geo 5xx,boiler,173,hpin1opt,input 1 options,string, ,true,sensor.boiler_input_1_options,sensor.boiler_hpin1opt +Geo 5xx,boiler,173,hpin2,input 2 state,boolean, ,false,binary_sensor.boiler_input_2_state,binary_sensor.boiler_hpin2 Geo 5xx,boiler,173,hpin2opt,input 2 options,string, ,true,sensor.boiler_input_2_options,sensor.boiler_hpin2opt +Geo 5xx,boiler,173,hpin3,input 3 state,boolean, ,false,binary_sensor.boiler_input_3_state,binary_sensor.boiler_hpin3 Geo 5xx,boiler,173,hpin3opt,input 3 options,string, ,true,sensor.boiler_input_3_options,sensor.boiler_hpin3opt +Geo 5xx,boiler,173,hpin4,input 4 state,boolean, ,false,binary_sensor.boiler_input_4_state,binary_sensor.boiler_hpin4 Geo 5xx,boiler,173,hpin4opt,input 4 options,string, ,true,sensor.boiler_input_4_options,sensor.boiler_hpin4opt Geo 5xx,boiler,173,maxheatcomp,heat limit compressor,enum [0 kW\|2 kW\|3 kW\|4 kW\|6 kW\|9 kW], ,true,select.boiler_heat_limit_compressor,select.boiler_maxheatcomp Geo 5xx,boiler,173,maxheatheat,heat limit heating,enum [0 kW\|2 kW\|3 kW\|4 kW\|6 kW\|9 kW], ,true,select.boiler_heat_limit_heating,select.boiler_maxheatheat -Geo 5xx,boiler,173,maxheatdhw,heat limit,enum [0 kW\|2 kW\|3 kW\|4 kW\|6 kW\|9 kW], ,true,select.boiler_dhw_heat_limit,select.boiler_dhw_maxheatdhw +Geo 5xx,boiler,173,maxheat,heat limit,enum [0 kW\|2 kW\|3 kW\|4 kW\|6 kW\|9 kW], ,true,select.boiler_dhw_heat_limit,select.boiler_dhw_maxheat Geo 5xx,boiler,173,mandefrost,manual defrost,boolean, ,true,switch.boiler_manual_defrost,switch.boiler_mandefrost Geo 5xx,boiler,173,pvcooling,cooling only with PV,boolean, ,true,switch.boiler_cooling_only_with_PV,switch.boiler_pvcooling Geo 5xx,boiler,173,auxheateronly,aux heater only,boolean, ,true,switch.boiler_aux_heater_only,switch.boiler_auxheateronly @@ -2411,10 +2443,10 @@ Geo 5xx,boiler,173,elheatstep3,el. heater step 3,boolean, ,true,switch.boiler_el Geo 5xx,boiler,173,hpea0,condensate reservoir heating (EA0),boolean, ,false,binary_sensor.boiler_condensate_reservoir_heating_(EA0),binary_sensor.boiler_hpea0 Geo 5xx,boiler,173,hppumpmode,primary heatpump mode,enum [auto\|continuous], ,true,select.boiler_primary_heatpump_mode,select.boiler_hppumpmode Geo 5xx,boiler,173,fan,fan,uint8 (>=20<=100),%,true,number.boiler_fan,number.boiler_fan -Geo 5xx,boiler,173,shutdown,shutdown,boolean, ,true,switch.boiler_shutdown,switch.boiler_shutdown +Geo 5xx,boiler,173,shutdown,shutdown,cmd [off\|on], ,true,sensor.boiler_shutdown,sensor.boiler_shutdown Geo 5xx,boiler,173,alternatingop,alternating operation,boolean, ,true,switch.boiler_dhw_alternating_operation,switch.boiler_dhw_alternatingop Geo 5xx,boiler,173,altopprioheat,prioritise heating during dhw,uint8 (>=20<=120),minutes,true,number.boiler_dhw_prioritise_heating_during_dhw,number.boiler_dhw_altopprioheat -Geo 5xx,boiler,173,altoppriodhw,prioritise dhw during heating,uint8 (>=30<=120),minutes,true,number.boiler_dhw_prioritise_dhw_during_heating,number.boiler_dhw_altoppriodhw +Geo 5xx,boiler,173,altopprio,prioritise dhw during heating,uint8 (>=30<=120),minutes,true,number.boiler_dhw_prioritise_dhw_during_heating,number.boiler_dhw_altopprio Geo 5xx,boiler,173,comfoff,comfort switch off,uint8 (>=15<=65),C,true,number.boiler_dhw_comfort_switch_off,number.boiler_dhw_comfoff Geo 5xx,boiler,173,ecooff,eco switch off,uint8 (>=15<=65),C,true,number.boiler_dhw_eco_switch_off,number.boiler_dhw_ecooff Geo 5xx,boiler,173,ecoplusoff,eco+ switch off,uint8 (>=48<=63),C,true,number.boiler_dhw_eco+_switch_off,number.boiler_dhw_ecoplusoff @@ -2424,7 +2456,7 @@ Geo 5xx,boiler,173,ecoplusdiff,eco+ diff,uint8 (>=6<=12),K,true,number.boiler_dh Geo 5xx,boiler,173,comfstop,comfort stop temp,uint8 (>=0<=254),C,true,number.boiler_dhw_comfort_stop_temp,number.boiler_dhw_comfstop Geo 5xx,boiler,173,ecostop,eco stop temp,uint8 (>=0<=254),C,true,number.boiler_dhw_eco_stop_temp,number.boiler_dhw_ecostop Geo 5xx,boiler,173,ecoplusstop,eco+ stop temp,uint8 (>=0<=254),C,true,number.boiler_dhw_eco+_stop_temp,number.boiler_dhw_ecoplusstop -Geo 5xx,boiler,173,hpcircpumpdhw,circulation pump available during dhw,boolean, ,true,switch.boiler_dhw_circulation_pump_available_during_dhw,switch.boiler_dhw_hpcircpumpdhw +Geo 5xx,boiler,173,hpcircpump,circulation pump available during dhw,boolean, ,true,switch.boiler_dhw_circulation_pump_available_during_dhw,switch.boiler_dhw_hpcircpump Geo 5xx,boiler,173,tapactivated,turn on/off,boolean, ,true,switch.boiler_dhw_turn_on/off,switch.boiler_dhw_tapactivated Geo 5xx,boiler,173,settemp,set temperature,uint8 (>=0<=254),C,false,sensor.boiler_dhw_set_temperature,sensor.boiler_dhw_settemp Geo 5xx,boiler,173,seltemp,selected temperature,uint8 (>=0<=254),C,true,number.boiler_dhw_selected_temperature,number.boiler_dhw_seltemp @@ -2497,7 +2529,7 @@ Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,boil2hystoff,hysteresi Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,curveon,heatingcurve on,boolean, ,true,switch.boiler_heatingcurve_on,switch.boiler_curveon Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,curvebase,heatingcurve base,uint8 (>=20<=90),C,true,number.boiler_heatingcurve_base,number.boiler_curvebase Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,curveend,heatingcurve end,uint8 (>=20<=90),C,true,number.boiler_heatingcurve_end,number.boiler_curveend -Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,summertemp,summer temperature,uint8 (>=0<=30),C,true,number.boiler_summer_temperature,number.boiler_summertemp +Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,summertemp,summer temperature,uint8 (>=0<=45),C,true,number.boiler_summer_temperature,number.boiler_summertemp Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,nofrostmode,nofrost mode,boolean, ,true,switch.boiler_nofrost_mode,switch.boiler_nofrostmode Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,nofrosttemp,nofrost temperature,uint8 (>=0<=10),C,true,number.boiler_nofrost_temperature,number.boiler_nofrosttemp Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,heatingactivated,heating activated,boolean, ,true,switch.boiler_heating_activated,switch.boiler_heatingactivated @@ -2506,6 +2538,7 @@ Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,heatingpump,heating pu Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,pumpmodmax,boiler pump max power,uint8 (>=0<=100),%,true,number.boiler_boiler_pump_max_power,number.boiler_pumpmodmax Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,pumpmodmin,boiler pump min power,uint8 (>=0<=100),%,true,number.boiler_boiler_pump_min_power,number.boiler_pumpmodmin Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,pumpmode,boiler pump mode,enum [proportional\|deltaP-1\|deltaP-2\|deltaP-3\|deltaP-4], ,true,select.boiler_boiler_pump_mode,select.boiler_pumpmode +Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,pumpcharacter,boiler pump characteristic,enum [proportional\|150mbar\|200mbar\|250mbar\|300mbar\|350mbar\|400mbar], ,true,select.boiler_boiler_pump_characteristic,select.boiler_pumpcharacter Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,pumpdelay,pump delay,uint8 (>=0<=60),minutes,true,number.boiler_pump_delay,number.boiler_pumpdelay Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,setflowtemp,set flow temperature,uint8 (>=0<=254),C,false,sensor.boiler_set_flow_temperature,sensor.boiler_setflowtemp Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,setburnpow,burner set power,uint8 (>=0<=100),%,false,sensor.boiler_burner_set_power,sensor.boiler_setburnpow @@ -2527,11 +2560,11 @@ Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,maintenancedate,next m Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,emergencyops,emergency operation,boolean, ,true,switch.boiler_emergency_operation,switch.boiler_emergencyops Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,emergencytemp,emergency temperature,uint8 (>=15<=70),C,true,number.boiler_emergency_temperature,number.boiler_emergencytemp Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,meterheat,meter heating,uint24 (>=0<=1677721),kWh,false,sensor.boiler_meter_heating,sensor.boiler_meterheat -Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,meterdhw,meter,uint24 (>=0<=1677721),kWh,false,sensor.boiler_dhw_meter,sensor.boiler_dhw_meterdhw +Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,meter,meter,uint24 (>=0<=1677721),kWh,false,sensor.boiler_dhw_meter,sensor.boiler_dhw_meter Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,gasmeterheat,gas meter heating,uint24 (>=0<=1677721),kWh,false,sensor.boiler_gas_meter_heating,sensor.boiler_gasmeterheat -Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,gasmeterdhw,gas meter,uint24 (>=0<=1677721),kWh,false,sensor.boiler_dhw_gas_meter,sensor.boiler_dhw_gasmeterdhw +Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,gasmeter,gas meter,uint24 (>=0<=1677721),kWh,false,sensor.boiler_dhw_gas_meter,sensor.boiler_dhw_gasmeter Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,nrgheat2,energy heating 2,uint24 (>=0<=1677721),kWh,false,sensor.boiler_energy_heating_2,sensor.boiler_nrgheat2 -Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,nrgdhw2,energy 2,uint24 (>=0<=1677721),kWh,false,sensor.boiler_dhw_energy_2,sensor.boiler_dhw_nrgdhw2 +Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,nrg2,energy 2,uint24 (>=0<=1677721),kWh,false,sensor.boiler_dhw_energy_2,sensor.boiler_dhw_nrg2 Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,tapactivated,turn on/off,boolean, ,true,switch.boiler_dhw_turn_on/off,switch.boiler_dhw_tapactivated Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,settemp,set temperature,uint8 (>=0<=254),C,false,sensor.boiler_dhw_set_temperature,sensor.boiler_dhw_settemp Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,seltemp,selected temperature,uint8 (>=0<=254),C,true,number.boiler_dhw_selected_temperature,number.boiler_dhw_seltemp @@ -2575,7 +2608,7 @@ Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,workm,active time,time Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,nompower,nominal Power,uint8 (>=0<=254),kW,true,number.boiler_nominal_Power,number.boiler_nompower Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,nrgtotal,total energy,uint24 (>=0<=167772),kWh,false,sensor.boiler_total_energy,sensor.boiler_nrgtotal Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,nrgheat,energy heating,uint24 (>=0<=10000000),kWh,true,number.boiler_energy_heating,number.boiler_nrgheat -Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,nrgdhw,energy,uint24 (>=0<=10000000),kWh,true,number.boiler_dhw_energy,number.boiler_dhw_nrgdhw +Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2,boiler,195,nrg,energy,uint24 (>=0<=10000000),kWh,true,number.boiler_dhw_energy,number.boiler_dhw_nrg Logamax U122/Cerapur,boiler,203,reset,reset,cmd [-\|maintenance\|error\|history\|message], ,true,sensor.boiler_reset,sensor.boiler_reset Logamax U122/Cerapur,boiler,203,heatingoff,force heating off,boolean, ,true,switch.boiler_force_heating_off,switch.boiler_heatingoff Logamax U122/Cerapur,boiler,203,heatingactive,heating active,boolean, ,false,binary_sensor.boiler_heating_active,binary_sensor.boiler_heatingactive @@ -2608,7 +2641,7 @@ Logamax U122/Cerapur,boiler,203,boil2hystoff,hysteresis stage 2 off temperature, Logamax U122/Cerapur,boiler,203,curveon,heatingcurve on,boolean, ,true,switch.boiler_heatingcurve_on,switch.boiler_curveon Logamax U122/Cerapur,boiler,203,curvebase,heatingcurve base,uint8 (>=20<=90),C,true,number.boiler_heatingcurve_base,number.boiler_curvebase Logamax U122/Cerapur,boiler,203,curveend,heatingcurve end,uint8 (>=20<=90),C,true,number.boiler_heatingcurve_end,number.boiler_curveend -Logamax U122/Cerapur,boiler,203,summertemp,summer temperature,uint8 (>=0<=30),C,true,number.boiler_summer_temperature,number.boiler_summertemp +Logamax U122/Cerapur,boiler,203,summertemp,summer temperature,uint8 (>=0<=45),C,true,number.boiler_summer_temperature,number.boiler_summertemp Logamax U122/Cerapur,boiler,203,nofrostmode,nofrost mode,boolean, ,true,switch.boiler_nofrost_mode,switch.boiler_nofrostmode Logamax U122/Cerapur,boiler,203,nofrosttemp,nofrost temperature,uint8 (>=0<=10),C,true,number.boiler_nofrost_temperature,number.boiler_nofrosttemp Logamax U122/Cerapur,boiler,203,heatingactivated,heating activated,boolean, ,true,switch.boiler_heating_activated,switch.boiler_heatingactivated @@ -2617,6 +2650,7 @@ Logamax U122/Cerapur,boiler,203,heatingpump,heating pump,boolean, ,false,binary_ Logamax U122/Cerapur,boiler,203,pumpmodmax,boiler pump max power,uint8 (>=0<=100),%,true,number.boiler_boiler_pump_max_power,number.boiler_pumpmodmax Logamax U122/Cerapur,boiler,203,pumpmodmin,boiler pump min power,uint8 (>=0<=100),%,true,number.boiler_boiler_pump_min_power,number.boiler_pumpmodmin Logamax U122/Cerapur,boiler,203,pumpmode,boiler pump mode,enum [proportional\|deltaP-1\|deltaP-2\|deltaP-3\|deltaP-4], ,true,select.boiler_boiler_pump_mode,select.boiler_pumpmode +Logamax U122/Cerapur,boiler,203,pumpcharacter,boiler pump characteristic,enum [proportional\|150mbar\|200mbar\|250mbar\|300mbar\|350mbar\|400mbar], ,true,select.boiler_boiler_pump_characteristic,select.boiler_pumpcharacter Logamax U122/Cerapur,boiler,203,pumpdelay,pump delay,uint8 (>=0<=60),minutes,true,number.boiler_pump_delay,number.boiler_pumpdelay Logamax U122/Cerapur,boiler,203,setflowtemp,set flow temperature,uint8 (>=0<=254),C,false,sensor.boiler_set_flow_temperature,sensor.boiler_setflowtemp Logamax U122/Cerapur,boiler,203,setburnpow,burner set power,uint8 (>=0<=100),%,false,sensor.boiler_burner_set_power,sensor.boiler_setburnpow @@ -2638,11 +2672,11 @@ Logamax U122/Cerapur,boiler,203,maintenancedate,next maintenance date,string, ,t Logamax U122/Cerapur,boiler,203,emergencyops,emergency operation,boolean, ,true,switch.boiler_emergency_operation,switch.boiler_emergencyops Logamax U122/Cerapur,boiler,203,emergencytemp,emergency temperature,uint8 (>=15<=70),C,true,number.boiler_emergency_temperature,number.boiler_emergencytemp Logamax U122/Cerapur,boiler,203,meterheat,meter heating,uint24 (>=0<=1677721),kWh,false,sensor.boiler_meter_heating,sensor.boiler_meterheat -Logamax U122/Cerapur,boiler,203,meterdhw,meter,uint24 (>=0<=1677721),kWh,false,sensor.boiler_dhw_meter,sensor.boiler_dhw_meterdhw +Logamax U122/Cerapur,boiler,203,meter,meter,uint24 (>=0<=1677721),kWh,false,sensor.boiler_dhw_meter,sensor.boiler_dhw_meter Logamax U122/Cerapur,boiler,203,gasmeterheat,gas meter heating,uint24 (>=0<=1677721),kWh,false,sensor.boiler_gas_meter_heating,sensor.boiler_gasmeterheat -Logamax U122/Cerapur,boiler,203,gasmeterdhw,gas meter,uint24 (>=0<=1677721),kWh,false,sensor.boiler_dhw_gas_meter,sensor.boiler_dhw_gasmeterdhw +Logamax U122/Cerapur,boiler,203,gasmeter,gas meter,uint24 (>=0<=1677721),kWh,false,sensor.boiler_dhw_gas_meter,sensor.boiler_dhw_gasmeter Logamax U122/Cerapur,boiler,203,nrgheat2,energy heating 2,uint24 (>=0<=1677721),kWh,false,sensor.boiler_energy_heating_2,sensor.boiler_nrgheat2 -Logamax U122/Cerapur,boiler,203,nrgdhw2,energy 2,uint24 (>=0<=1677721),kWh,false,sensor.boiler_dhw_energy_2,sensor.boiler_dhw_nrgdhw2 +Logamax U122/Cerapur,boiler,203,nrg2,energy 2,uint24 (>=0<=1677721),kWh,false,sensor.boiler_dhw_energy_2,sensor.boiler_dhw_nrg2 Logamax U122/Cerapur,boiler,203,tapactivated,turn on/off,boolean, ,true,switch.boiler_dhw_turn_on/off,switch.boiler_dhw_tapactivated Logamax U122/Cerapur,boiler,203,settemp,set temperature,uint8 (>=0<=254),C,false,sensor.boiler_dhw_set_temperature,sensor.boiler_dhw_settemp Logamax U122/Cerapur,boiler,203,seltemp,selected temperature,uint8 (>=0<=254),C,true,number.boiler_dhw_selected_temperature,number.boiler_dhw_seltemp @@ -2686,7 +2720,7 @@ Logamax U122/Cerapur,boiler,203,workm,active time,time (>=0<=16777213),minutes,f Logamax U122/Cerapur,boiler,203,nompower,nominal Power,uint8 (>=0<=254),kW,true,number.boiler_nominal_Power,number.boiler_nompower Logamax U122/Cerapur,boiler,203,nrgtotal,total energy,uint24 (>=0<=167772),kWh,false,sensor.boiler_total_energy,sensor.boiler_nrgtotal Logamax U122/Cerapur,boiler,203,nrgheat,energy heating,uint24 (>=0<=10000000),kWh,true,number.boiler_energy_heating,number.boiler_nrgheat -Logamax U122/Cerapur,boiler,203,nrgdhw,energy,uint24 (>=0<=10000000),kWh,true,number.boiler_dhw_energy,number.boiler_dhw_nrgdhw +Logamax U122/Cerapur,boiler,203,nrg,energy,uint24 (>=0<=10000000),kWh,true,number.boiler_dhw_energy,number.boiler_dhw_nrg Ecomline Excellent,boiler,206,reset,reset,cmd [-\|maintenance\|error\|history\|message], ,true,sensor.boiler_reset,sensor.boiler_reset Ecomline Excellent,boiler,206,heatingoff,force heating off,boolean, ,true,switch.boiler_force_heating_off,switch.boiler_heatingoff Ecomline Excellent,boiler,206,heatingactive,heating active,boolean, ,false,binary_sensor.boiler_heating_active,binary_sensor.boiler_heatingactive @@ -2719,7 +2753,7 @@ Ecomline Excellent,boiler,206,boil2hystoff,hysteresis stage 2 off temperature,in Ecomline Excellent,boiler,206,curveon,heatingcurve on,boolean, ,true,switch.boiler_heatingcurve_on,switch.boiler_curveon Ecomline Excellent,boiler,206,curvebase,heatingcurve base,uint8 (>=20<=90),C,true,number.boiler_heatingcurve_base,number.boiler_curvebase Ecomline Excellent,boiler,206,curveend,heatingcurve end,uint8 (>=20<=90),C,true,number.boiler_heatingcurve_end,number.boiler_curveend -Ecomline Excellent,boiler,206,summertemp,summer temperature,uint8 (>=0<=30),C,true,number.boiler_summer_temperature,number.boiler_summertemp +Ecomline Excellent,boiler,206,summertemp,summer temperature,uint8 (>=0<=45),C,true,number.boiler_summer_temperature,number.boiler_summertemp Ecomline Excellent,boiler,206,nofrostmode,nofrost mode,boolean, ,true,switch.boiler_nofrost_mode,switch.boiler_nofrostmode Ecomline Excellent,boiler,206,nofrosttemp,nofrost temperature,uint8 (>=0<=10),C,true,number.boiler_nofrost_temperature,number.boiler_nofrosttemp Ecomline Excellent,boiler,206,heatingactivated,heating activated,boolean, ,true,switch.boiler_heating_activated,switch.boiler_heatingactivated @@ -2728,6 +2762,7 @@ Ecomline Excellent,boiler,206,heatingpump,heating pump,boolean, ,false,binary_se Ecomline Excellent,boiler,206,pumpmodmax,boiler pump max power,uint8 (>=0<=100),%,true,number.boiler_boiler_pump_max_power,number.boiler_pumpmodmax Ecomline Excellent,boiler,206,pumpmodmin,boiler pump min power,uint8 (>=0<=100),%,true,number.boiler_boiler_pump_min_power,number.boiler_pumpmodmin Ecomline Excellent,boiler,206,pumpmode,boiler pump mode,enum [proportional\|deltaP-1\|deltaP-2\|deltaP-3\|deltaP-4], ,true,select.boiler_boiler_pump_mode,select.boiler_pumpmode +Ecomline Excellent,boiler,206,pumpcharacter,boiler pump characteristic,enum [proportional\|150mbar\|200mbar\|250mbar\|300mbar\|350mbar\|400mbar], ,true,select.boiler_boiler_pump_characteristic,select.boiler_pumpcharacter Ecomline Excellent,boiler,206,pumpdelay,pump delay,uint8 (>=0<=60),minutes,true,number.boiler_pump_delay,number.boiler_pumpdelay Ecomline Excellent,boiler,206,setflowtemp,set flow temperature,uint8 (>=0<=254),C,false,sensor.boiler_set_flow_temperature,sensor.boiler_setflowtemp Ecomline Excellent,boiler,206,setburnpow,burner set power,uint8 (>=0<=100),%,false,sensor.boiler_burner_set_power,sensor.boiler_setburnpow @@ -2749,11 +2784,11 @@ Ecomline Excellent,boiler,206,maintenancedate,next maintenance date,string, ,tru Ecomline Excellent,boiler,206,emergencyops,emergency operation,boolean, ,true,switch.boiler_emergency_operation,switch.boiler_emergencyops Ecomline Excellent,boiler,206,emergencytemp,emergency temperature,uint8 (>=15<=70),C,true,number.boiler_emergency_temperature,number.boiler_emergencytemp Ecomline Excellent,boiler,206,meterheat,meter heating,uint24 (>=0<=1677721),kWh,false,sensor.boiler_meter_heating,sensor.boiler_meterheat -Ecomline Excellent,boiler,206,meterdhw,meter,uint24 (>=0<=1677721),kWh,false,sensor.boiler_dhw_meter,sensor.boiler_dhw_meterdhw +Ecomline Excellent,boiler,206,meter,meter,uint24 (>=0<=1677721),kWh,false,sensor.boiler_dhw_meter,sensor.boiler_dhw_meter Ecomline Excellent,boiler,206,gasmeterheat,gas meter heating,uint24 (>=0<=1677721),kWh,false,sensor.boiler_gas_meter_heating,sensor.boiler_gasmeterheat -Ecomline Excellent,boiler,206,gasmeterdhw,gas meter,uint24 (>=0<=1677721),kWh,false,sensor.boiler_dhw_gas_meter,sensor.boiler_dhw_gasmeterdhw +Ecomline Excellent,boiler,206,gasmeter,gas meter,uint24 (>=0<=1677721),kWh,false,sensor.boiler_dhw_gas_meter,sensor.boiler_dhw_gasmeter Ecomline Excellent,boiler,206,nrgheat2,energy heating 2,uint24 (>=0<=1677721),kWh,false,sensor.boiler_energy_heating_2,sensor.boiler_nrgheat2 -Ecomline Excellent,boiler,206,nrgdhw2,energy 2,uint24 (>=0<=1677721),kWh,false,sensor.boiler_dhw_energy_2,sensor.boiler_dhw_nrgdhw2 +Ecomline Excellent,boiler,206,nrg2,energy 2,uint24 (>=0<=1677721),kWh,false,sensor.boiler_dhw_energy_2,sensor.boiler_dhw_nrg2 Ecomline Excellent,boiler,206,tapactivated,turn on/off,boolean, ,true,switch.boiler_dhw_turn_on/off,switch.boiler_dhw_tapactivated Ecomline Excellent,boiler,206,settemp,set temperature,uint8 (>=0<=254),C,false,sensor.boiler_dhw_set_temperature,sensor.boiler_dhw_settemp Ecomline Excellent,boiler,206,seltemp,selected temperature,uint8 (>=0<=254),C,true,number.boiler_dhw_selected_temperature,number.boiler_dhw_seltemp @@ -2797,7 +2832,7 @@ Ecomline Excellent,boiler,206,workm,active time,time (>=0<=16777213),minutes,fal Ecomline Excellent,boiler,206,nompower,nominal Power,uint8 (>=0<=254),kW,true,number.boiler_nominal_Power,number.boiler_nompower Ecomline Excellent,boiler,206,nrgtotal,total energy,uint24 (>=0<=167772),kWh,false,sensor.boiler_total_energy,sensor.boiler_nrgtotal Ecomline Excellent,boiler,206,nrgheat,energy heating,uint24 (>=0<=10000000),kWh,true,number.boiler_energy_heating,number.boiler_nrgheat -Ecomline Excellent,boiler,206,nrgdhw,energy,uint24 (>=0<=10000000),kWh,true,number.boiler_dhw_energy,number.boiler_dhw_nrgdhw +Ecomline Excellent,boiler,206,nrg,energy,uint24 (>=0<=10000000),kWh,true,number.boiler_dhw_energy,number.boiler_dhw_nrg Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,reset,reset,cmd [-\|maintenance\|error\|history\|message], ,true,sensor.boiler_reset,sensor.boiler_reset Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,heatingoff,force heating off,boolean, ,true,switch.boiler_force_heating_off,switch.boiler_heatingoff Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,heatingactive,heating active,boolean, ,false,binary_sensor.boiler_heating_active,binary_sensor.boiler_heatingactive @@ -2830,7 +2865,7 @@ Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,boil2hystoff,hysteres Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,curveon,heatingcurve on,boolean, ,true,switch.boiler_heatingcurve_on,switch.boiler_curveon Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,curvebase,heatingcurve base,uint8 (>=20<=90),C,true,number.boiler_heatingcurve_base,number.boiler_curvebase Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,curveend,heatingcurve end,uint8 (>=20<=90),C,true,number.boiler_heatingcurve_end,number.boiler_curveend -Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,summertemp,summer temperature,uint8 (>=0<=30),C,true,number.boiler_summer_temperature,number.boiler_summertemp +Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,summertemp,summer temperature,uint8 (>=0<=45),C,true,number.boiler_summer_temperature,number.boiler_summertemp Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,nofrostmode,nofrost mode,boolean, ,true,switch.boiler_nofrost_mode,switch.boiler_nofrostmode Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,nofrosttemp,nofrost temperature,uint8 (>=0<=10),C,true,number.boiler_nofrost_temperature,number.boiler_nofrosttemp Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,heatingactivated,heating activated,boolean, ,true,switch.boiler_heating_activated,switch.boiler_heatingactivated @@ -2839,6 +2874,7 @@ Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,heatingpump,heating p Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,pumpmodmax,boiler pump max power,uint8 (>=0<=100),%,true,number.boiler_boiler_pump_max_power,number.boiler_pumpmodmax Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,pumpmodmin,boiler pump min power,uint8 (>=0<=100),%,true,number.boiler_boiler_pump_min_power,number.boiler_pumpmodmin Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,pumpmode,boiler pump mode,enum [proportional\|deltaP-1\|deltaP-2\|deltaP-3\|deltaP-4], ,true,select.boiler_boiler_pump_mode,select.boiler_pumpmode +Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,pumpcharacter,boiler pump characteristic,enum [proportional\|150mbar\|200mbar\|250mbar\|300mbar\|350mbar\|400mbar], ,true,select.boiler_boiler_pump_characteristic,select.boiler_pumpcharacter Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,pumpdelay,pump delay,uint8 (>=0<=60),minutes,true,number.boiler_pump_delay,number.boiler_pumpdelay Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,setflowtemp,set flow temperature,uint8 (>=0<=254),C,false,sensor.boiler_set_flow_temperature,sensor.boiler_setflowtemp Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,setburnpow,burner set power,uint8 (>=0<=100),%,false,sensor.boiler_burner_set_power,sensor.boiler_setburnpow @@ -2860,11 +2896,11 @@ Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,maintenancedate,next Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,emergencyops,emergency operation,boolean, ,true,switch.boiler_emergency_operation,switch.boiler_emergencyops Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,emergencytemp,emergency temperature,uint8 (>=15<=70),C,true,number.boiler_emergency_temperature,number.boiler_emergencytemp Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,meterheat,meter heating,uint24 (>=0<=1677721),kWh,false,sensor.boiler_meter_heating,sensor.boiler_meterheat -Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,meterdhw,meter,uint24 (>=0<=1677721),kWh,false,sensor.boiler_dhw_meter,sensor.boiler_dhw_meterdhw +Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,meter,meter,uint24 (>=0<=1677721),kWh,false,sensor.boiler_dhw_meter,sensor.boiler_dhw_meter Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,gasmeterheat,gas meter heating,uint24 (>=0<=1677721),kWh,false,sensor.boiler_gas_meter_heating,sensor.boiler_gasmeterheat -Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,gasmeterdhw,gas meter,uint24 (>=0<=1677721),kWh,false,sensor.boiler_dhw_gas_meter,sensor.boiler_dhw_gasmeterdhw +Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,gasmeter,gas meter,uint24 (>=0<=1677721),kWh,false,sensor.boiler_dhw_gas_meter,sensor.boiler_dhw_gasmeter Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,nrgheat2,energy heating 2,uint24 (>=0<=1677721),kWh,false,sensor.boiler_energy_heating_2,sensor.boiler_nrgheat2 -Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,nrgdhw2,energy 2,uint24 (>=0<=1677721),kWh,false,sensor.boiler_dhw_energy_2,sensor.boiler_dhw_nrgdhw2 +Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,nrg2,energy 2,uint24 (>=0<=1677721),kWh,false,sensor.boiler_dhw_energy_2,sensor.boiler_dhw_nrg2 Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,tapactivated,turn on/off,boolean, ,true,switch.boiler_dhw_turn_on/off,switch.boiler_dhw_tapactivated Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,settemp,set temperature,uint8 (>=0<=254),C,false,sensor.boiler_dhw_set_temperature,sensor.boiler_dhw_settemp Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,seltemp,selected temperature,uint8 (>=0<=254),C,true,number.boiler_dhw_selected_temperature,number.boiler_dhw_seltemp @@ -2908,7 +2944,7 @@ Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,workm,active time,tim Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,nompower,nominal Power,uint8 (>=0<=254),kW,true,number.boiler_nominal_Power,number.boiler_nompower Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,nrgtotal,total energy,uint24 (>=0<=167772),kWh,false,sensor.boiler_total_energy,sensor.boiler_nrgtotal Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,nrgheat,energy heating,uint24 (>=0<=10000000),kWh,true,number.boiler_energy_heating,number.boiler_nrgheat -Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,nrgdhw,energy,uint24 (>=0<=10000000),kWh,true,number.boiler_dhw_energy,number.boiler_dhw_nrgdhw +Logamax Plus/GB192/Condens GC9000/Greenstar ErP,boiler,208,nrg,energy,uint24 (>=0<=10000000),kWh,true,number.boiler_dhw_energy,number.boiler_dhw_nrg Cascade MC400,boiler,210,reset,reset,cmd [-\|maintenance\|error\|history\|message], ,true,sensor.boiler_reset,sensor.boiler_reset Cascade MC400,boiler,210,heatingoff,force heating off,boolean, ,true,switch.boiler_force_heating_off,switch.boiler_heatingoff Cascade MC400,boiler,210,heatingactive,heating active,boolean, ,false,binary_sensor.boiler_heating_active,binary_sensor.boiler_heatingactive @@ -2941,7 +2977,7 @@ Cascade MC400,boiler,210,boil2hystoff,hysteresis stage 2 off temperature,int8 (> Cascade MC400,boiler,210,curveon,heatingcurve on,boolean, ,true,switch.boiler_heatingcurve_on,switch.boiler_curveon Cascade MC400,boiler,210,curvebase,heatingcurve base,uint8 (>=20<=90),C,true,number.boiler_heatingcurve_base,number.boiler_curvebase Cascade MC400,boiler,210,curveend,heatingcurve end,uint8 (>=20<=90),C,true,number.boiler_heatingcurve_end,number.boiler_curveend -Cascade MC400,boiler,210,summertemp,summer temperature,uint8 (>=0<=30),C,true,number.boiler_summer_temperature,number.boiler_summertemp +Cascade MC400,boiler,210,summertemp,summer temperature,uint8 (>=0<=45),C,true,number.boiler_summer_temperature,number.boiler_summertemp Cascade MC400,boiler,210,nofrostmode,nofrost mode,boolean, ,true,switch.boiler_nofrost_mode,switch.boiler_nofrostmode Cascade MC400,boiler,210,nofrosttemp,nofrost temperature,uint8 (>=0<=10),C,true,number.boiler_nofrost_temperature,number.boiler_nofrosttemp Cascade MC400,boiler,210,heatingactivated,heating activated,boolean, ,true,switch.boiler_heating_activated,switch.boiler_heatingactivated @@ -2950,6 +2986,7 @@ Cascade MC400,boiler,210,heatingpump,heating pump,boolean, ,false,binary_sensor. Cascade MC400,boiler,210,pumpmodmax,boiler pump max power,uint8 (>=0<=100),%,true,number.boiler_boiler_pump_max_power,number.boiler_pumpmodmax Cascade MC400,boiler,210,pumpmodmin,boiler pump min power,uint8 (>=0<=100),%,true,number.boiler_boiler_pump_min_power,number.boiler_pumpmodmin Cascade MC400,boiler,210,pumpmode,boiler pump mode,enum [proportional\|deltaP-1\|deltaP-2\|deltaP-3\|deltaP-4], ,true,select.boiler_boiler_pump_mode,select.boiler_pumpmode +Cascade MC400,boiler,210,pumpcharacter,boiler pump characteristic,enum [proportional\|150mbar\|200mbar\|250mbar\|300mbar\|350mbar\|400mbar], ,true,select.boiler_boiler_pump_characteristic,select.boiler_pumpcharacter Cascade MC400,boiler,210,pumpdelay,pump delay,uint8 (>=0<=60),minutes,true,number.boiler_pump_delay,number.boiler_pumpdelay Cascade MC400,boiler,210,setflowtemp,set flow temperature,uint8 (>=0<=254),C,false,sensor.boiler_set_flow_temperature,sensor.boiler_setflowtemp Cascade MC400,boiler,210,setburnpow,burner set power,uint8 (>=0<=100),%,false,sensor.boiler_burner_set_power,sensor.boiler_setburnpow @@ -2971,11 +3008,11 @@ Cascade MC400,boiler,210,maintenancedate,next maintenance date,string, ,true,sen Cascade MC400,boiler,210,emergencyops,emergency operation,boolean, ,true,switch.boiler_emergency_operation,switch.boiler_emergencyops Cascade MC400,boiler,210,emergencytemp,emergency temperature,uint8 (>=15<=70),C,true,number.boiler_emergency_temperature,number.boiler_emergencytemp Cascade MC400,boiler,210,meterheat,meter heating,uint24 (>=0<=1677721),kWh,false,sensor.boiler_meter_heating,sensor.boiler_meterheat -Cascade MC400,boiler,210,meterdhw,meter,uint24 (>=0<=1677721),kWh,false,sensor.boiler_dhw_meter,sensor.boiler_dhw_meterdhw +Cascade MC400,boiler,210,meter,meter,uint24 (>=0<=1677721),kWh,false,sensor.boiler_dhw_meter,sensor.boiler_dhw_meter Cascade MC400,boiler,210,gasmeterheat,gas meter heating,uint24 (>=0<=1677721),kWh,false,sensor.boiler_gas_meter_heating,sensor.boiler_gasmeterheat -Cascade MC400,boiler,210,gasmeterdhw,gas meter,uint24 (>=0<=1677721),kWh,false,sensor.boiler_dhw_gas_meter,sensor.boiler_dhw_gasmeterdhw +Cascade MC400,boiler,210,gasmeter,gas meter,uint24 (>=0<=1677721),kWh,false,sensor.boiler_dhw_gas_meter,sensor.boiler_dhw_gasmeter Cascade MC400,boiler,210,nrgheat2,energy heating 2,uint24 (>=0<=1677721),kWh,false,sensor.boiler_energy_heating_2,sensor.boiler_nrgheat2 -Cascade MC400,boiler,210,nrgdhw2,energy 2,uint24 (>=0<=1677721),kWh,false,sensor.boiler_dhw_energy_2,sensor.boiler_dhw_nrgdhw2 +Cascade MC400,boiler,210,nrg2,energy 2,uint24 (>=0<=1677721),kWh,false,sensor.boiler_dhw_energy_2,sensor.boiler_dhw_nrg2 Cascade MC400,boiler,210,tapactivated,turn on/off,boolean, ,true,switch.boiler_dhw_turn_on/off,switch.boiler_dhw_tapactivated Cascade MC400,boiler,210,settemp,set temperature,uint8 (>=0<=254),C,false,sensor.boiler_dhw_set_temperature,sensor.boiler_dhw_settemp Cascade MC400,boiler,210,seltemp,selected temperature,uint8 (>=0<=254),C,true,number.boiler_dhw_selected_temperature,number.boiler_dhw_seltemp @@ -3019,7 +3056,7 @@ Cascade MC400,boiler,210,workm,active time,time (>=0<=16777213),minutes,false,se Cascade MC400,boiler,210,nompower,nominal Power,uint8 (>=0<=254),kW,true,number.boiler_nominal_Power,number.boiler_nompower Cascade MC400,boiler,210,nrgtotal,total energy,uint24 (>=0<=167772),kWh,false,sensor.boiler_total_energy,sensor.boiler_nrgtotal Cascade MC400,boiler,210,nrgheat,energy heating,uint24 (>=0<=10000000),kWh,true,number.boiler_energy_heating,number.boiler_nrgheat -Cascade MC400,boiler,210,nrgdhw,energy,uint24 (>=0<=10000000),kWh,true,number.boiler_dhw_energy,number.boiler_dhw_nrgdhw +Cascade MC400,boiler,210,nrg,energy,uint24 (>=0<=10000000),kWh,true,number.boiler_dhw_energy,number.boiler_dhw_nrg EasyControl Adapter,boiler,211,reset,reset,cmd [-\|maintenance\|error\|history\|message], ,true,sensor.boiler_reset,sensor.boiler_reset EasyControl Adapter,boiler,211,heatingoff,force heating off,boolean, ,true,switch.boiler_force_heating_off,switch.boiler_heatingoff EasyControl Adapter,boiler,211,heatingactive,heating active,boolean, ,false,binary_sensor.boiler_heating_active,binary_sensor.boiler_heatingactive @@ -3052,7 +3089,7 @@ EasyControl Adapter,boiler,211,boil2hystoff,hysteresis stage 2 off temperature,i EasyControl Adapter,boiler,211,curveon,heatingcurve on,boolean, ,true,switch.boiler_heatingcurve_on,switch.boiler_curveon EasyControl Adapter,boiler,211,curvebase,heatingcurve base,uint8 (>=20<=90),C,true,number.boiler_heatingcurve_base,number.boiler_curvebase EasyControl Adapter,boiler,211,curveend,heatingcurve end,uint8 (>=20<=90),C,true,number.boiler_heatingcurve_end,number.boiler_curveend -EasyControl Adapter,boiler,211,summertemp,summer temperature,uint8 (>=0<=30),C,true,number.boiler_summer_temperature,number.boiler_summertemp +EasyControl Adapter,boiler,211,summertemp,summer temperature,uint8 (>=0<=45),C,true,number.boiler_summer_temperature,number.boiler_summertemp EasyControl Adapter,boiler,211,nofrostmode,nofrost mode,boolean, ,true,switch.boiler_nofrost_mode,switch.boiler_nofrostmode EasyControl Adapter,boiler,211,nofrosttemp,nofrost temperature,uint8 (>=0<=10),C,true,number.boiler_nofrost_temperature,number.boiler_nofrosttemp EasyControl Adapter,boiler,211,heatingactivated,heating activated,boolean, ,true,switch.boiler_heating_activated,switch.boiler_heatingactivated @@ -3061,6 +3098,7 @@ EasyControl Adapter,boiler,211,heatingpump,heating pump,boolean, ,false,binary_s EasyControl Adapter,boiler,211,pumpmodmax,boiler pump max power,uint8 (>=0<=100),%,true,number.boiler_boiler_pump_max_power,number.boiler_pumpmodmax EasyControl Adapter,boiler,211,pumpmodmin,boiler pump min power,uint8 (>=0<=100),%,true,number.boiler_boiler_pump_min_power,number.boiler_pumpmodmin EasyControl Adapter,boiler,211,pumpmode,boiler pump mode,enum [proportional\|deltaP-1\|deltaP-2\|deltaP-3\|deltaP-4], ,true,select.boiler_boiler_pump_mode,select.boiler_pumpmode +EasyControl Adapter,boiler,211,pumpcharacter,boiler pump characteristic,enum [proportional\|150mbar\|200mbar\|250mbar\|300mbar\|350mbar\|400mbar], ,true,select.boiler_boiler_pump_characteristic,select.boiler_pumpcharacter EasyControl Adapter,boiler,211,pumpdelay,pump delay,uint8 (>=0<=60),minutes,true,number.boiler_pump_delay,number.boiler_pumpdelay EasyControl Adapter,boiler,211,setflowtemp,set flow temperature,uint8 (>=0<=254),C,false,sensor.boiler_set_flow_temperature,sensor.boiler_setflowtemp EasyControl Adapter,boiler,211,setburnpow,burner set power,uint8 (>=0<=100),%,false,sensor.boiler_burner_set_power,sensor.boiler_setburnpow @@ -3082,11 +3120,11 @@ EasyControl Adapter,boiler,211,maintenancedate,next maintenance date,string, ,tr EasyControl Adapter,boiler,211,emergencyops,emergency operation,boolean, ,true,switch.boiler_emergency_operation,switch.boiler_emergencyops EasyControl Adapter,boiler,211,emergencytemp,emergency temperature,uint8 (>=15<=70),C,true,number.boiler_emergency_temperature,number.boiler_emergencytemp EasyControl Adapter,boiler,211,meterheat,meter heating,uint24 (>=0<=1677721),kWh,false,sensor.boiler_meter_heating,sensor.boiler_meterheat -EasyControl Adapter,boiler,211,meterdhw,meter,uint24 (>=0<=1677721),kWh,false,sensor.boiler_dhw_meter,sensor.boiler_dhw_meterdhw +EasyControl Adapter,boiler,211,meter,meter,uint24 (>=0<=1677721),kWh,false,sensor.boiler_dhw_meter,sensor.boiler_dhw_meter EasyControl Adapter,boiler,211,gasmeterheat,gas meter heating,uint24 (>=0<=1677721),kWh,false,sensor.boiler_gas_meter_heating,sensor.boiler_gasmeterheat -EasyControl Adapter,boiler,211,gasmeterdhw,gas meter,uint24 (>=0<=1677721),kWh,false,sensor.boiler_dhw_gas_meter,sensor.boiler_dhw_gasmeterdhw +EasyControl Adapter,boiler,211,gasmeter,gas meter,uint24 (>=0<=1677721),kWh,false,sensor.boiler_dhw_gas_meter,sensor.boiler_dhw_gasmeter EasyControl Adapter,boiler,211,nrgheat2,energy heating 2,uint24 (>=0<=1677721),kWh,false,sensor.boiler_energy_heating_2,sensor.boiler_nrgheat2 -EasyControl Adapter,boiler,211,nrgdhw2,energy 2,uint24 (>=0<=1677721),kWh,false,sensor.boiler_dhw_energy_2,sensor.boiler_dhw_nrgdhw2 +EasyControl Adapter,boiler,211,nrg2,energy 2,uint24 (>=0<=1677721),kWh,false,sensor.boiler_dhw_energy_2,sensor.boiler_dhw_nrg2 EasyControl Adapter,boiler,211,tapactivated,turn on/off,boolean, ,true,switch.boiler_dhw_turn_on/off,switch.boiler_dhw_tapactivated EasyControl Adapter,boiler,211,settemp,set temperature,uint8 (>=0<=254),C,false,sensor.boiler_dhw_set_temperature,sensor.boiler_dhw_settemp EasyControl Adapter,boiler,211,seltemp,selected temperature,uint8 (>=0<=254),C,true,number.boiler_dhw_selected_temperature,number.boiler_dhw_seltemp @@ -3130,7 +3168,7 @@ EasyControl Adapter,boiler,211,workm,active time,time (>=0<=16777213),minutes,fa EasyControl Adapter,boiler,211,nompower,nominal Power,uint8 (>=0<=254),kW,true,number.boiler_nominal_Power,number.boiler_nompower EasyControl Adapter,boiler,211,nrgtotal,total energy,uint24 (>=0<=167772),kWh,false,sensor.boiler_total_energy,sensor.boiler_nrgtotal EasyControl Adapter,boiler,211,nrgheat,energy heating,uint24 (>=0<=10000000),kWh,true,number.boiler_energy_heating,number.boiler_nrgheat -EasyControl Adapter,boiler,211,nrgdhw,energy,uint24 (>=0<=10000000),kWh,true,number.boiler_dhw_energy,number.boiler_dhw_nrgdhw +EasyControl Adapter,boiler,211,nrg,energy,uint24 (>=0<=10000000),kWh,true,number.boiler_dhw_energy,number.boiler_dhw_nrg Greenstar HIU/Logamax kompakt WS170,boiler,219,netflowtemp,heat network flow temp,uint16 (>=0<=3199),C,false,sensor.boiler_heat_network_flow_temp,sensor.boiler_netflowtemp Greenstar HIU/Logamax kompakt WS170,boiler,219,heatvalve,heating valve,uint8 (>=0<=100),%,false,sensor.boiler_heating_valve,sensor.boiler_heatvalve Greenstar HIU/Logamax kompakt WS170,boiler,219,dhwvalve,valve,uint8 (>=0<=100),%,false,sensor.boiler_dhw_valve,sensor.boiler_dhw_dhwvalve @@ -3157,6 +3195,7 @@ Greenstar HIU/Logamax kompakt WS170,boiler,219,heatingpump,heating pump,boolean, Greenstar HIU/Logamax kompakt WS170,boiler,219,pumpmodmax,boiler pump max power,uint8 (>=0<=100),%,true,number.boiler_boiler_pump_max_power,number.boiler_pumpmodmax Greenstar HIU/Logamax kompakt WS170,boiler,219,pumpmodmin,boiler pump min power,uint8 (>=0<=100),%,true,number.boiler_boiler_pump_min_power,number.boiler_pumpmodmin Greenstar HIU/Logamax kompakt WS170,boiler,219,pumpmode,boiler pump mode,enum [proportional\|deltaP-1\|deltaP-2\|deltaP-3\|deltaP-4], ,true,select.boiler_boiler_pump_mode,select.boiler_pumpmode +Greenstar HIU/Logamax kompakt WS170,boiler,219,pumpcharacter,boiler pump characteristic,enum [proportional\|150mbar\|200mbar\|250mbar\|300mbar\|350mbar\|400mbar], ,true,select.boiler_boiler_pump_characteristic,select.boiler_pumpcharacter Greenstar HIU/Logamax kompakt WS170,boiler,219,pumpdelay,pump delay,uint8 (>=0<=60),minutes,true,number.boiler_pump_delay,number.boiler_pumpdelay Greenstar HIU/Logamax kompakt WS170,boiler,219,setflowtemp,set flow temperature,uint8 (>=0<=254),C,false,sensor.boiler_set_flow_temperature,sensor.boiler_setflowtemp Greenstar HIU/Logamax kompakt WS170,boiler,219,setburnpow,burner set power,uint8 (>=0<=100),%,false,sensor.boiler_burner_set_power,sensor.boiler_setburnpow @@ -3178,11 +3217,11 @@ Greenstar HIU/Logamax kompakt WS170,boiler,219,maintenancedate,next maintenance Greenstar HIU/Logamax kompakt WS170,boiler,219,emergencyops,emergency operation,boolean, ,true,switch.boiler_emergency_operation,switch.boiler_emergencyops Greenstar HIU/Logamax kompakt WS170,boiler,219,emergencytemp,emergency temperature,uint8 (>=15<=70),C,true,number.boiler_emergency_temperature,number.boiler_emergencytemp Greenstar HIU/Logamax kompakt WS170,boiler,219,meterheat,meter heating,uint24 (>=0<=1677721),kWh,false,sensor.boiler_meter_heating,sensor.boiler_meterheat -Greenstar HIU/Logamax kompakt WS170,boiler,219,meterdhw,meter,uint24 (>=0<=1677721),kWh,false,sensor.boiler_dhw_meter,sensor.boiler_dhw_meterdhw +Greenstar HIU/Logamax kompakt WS170,boiler,219,meter,meter,uint24 (>=0<=1677721),kWh,false,sensor.boiler_dhw_meter,sensor.boiler_dhw_meter Greenstar HIU/Logamax kompakt WS170,boiler,219,gasmeterheat,gas meter heating,uint24 (>=0<=1677721),kWh,false,sensor.boiler_gas_meter_heating,sensor.boiler_gasmeterheat -Greenstar HIU/Logamax kompakt WS170,boiler,219,gasmeterdhw,gas meter,uint24 (>=0<=1677721),kWh,false,sensor.boiler_dhw_gas_meter,sensor.boiler_dhw_gasmeterdhw +Greenstar HIU/Logamax kompakt WS170,boiler,219,gasmeter,gas meter,uint24 (>=0<=1677721),kWh,false,sensor.boiler_dhw_gas_meter,sensor.boiler_dhw_gasmeter Greenstar HIU/Logamax kompakt WS170,boiler,219,nrgheat2,energy heating 2,uint24 (>=0<=1677721),kWh,false,sensor.boiler_energy_heating_2,sensor.boiler_nrgheat2 -Greenstar HIU/Logamax kompakt WS170,boiler,219,nrgdhw2,energy 2,uint24 (>=0<=1677721),kWh,false,sensor.boiler_dhw_energy_2,sensor.boiler_dhw_nrgdhw2 +Greenstar HIU/Logamax kompakt WS170,boiler,219,nrg2,energy 2,uint24 (>=0<=1677721),kWh,false,sensor.boiler_dhw_energy_2,sensor.boiler_dhw_nrg2 Greenstar HIU/Logamax kompakt WS170,boiler,219,tapactivated,turn on/off,boolean, ,true,switch.boiler_dhw_turn_on/off,switch.boiler_dhw_tapactivated Greenstar HIU/Logamax kompakt WS170,boiler,219,settemp,set temperature,uint8 (>=0<=254),C,false,sensor.boiler_dhw_set_temperature,sensor.boiler_dhw_settemp Greenstar HIU/Logamax kompakt WS170,boiler,219,seltemp,selected temperature,uint8 (>=0<=254),C,true,number.boiler_dhw_selected_temperature,number.boiler_dhw_seltemp @@ -3255,7 +3294,7 @@ Logamax Plus GB122/Condense 2300,boiler,234,boil2hystoff,hysteresis stage 2 off Logamax Plus GB122/Condense 2300,boiler,234,curveon,heatingcurve on,boolean, ,true,switch.boiler_heatingcurve_on,switch.boiler_curveon Logamax Plus GB122/Condense 2300,boiler,234,curvebase,heatingcurve base,uint8 (>=20<=90),C,true,number.boiler_heatingcurve_base,number.boiler_curvebase Logamax Plus GB122/Condense 2300,boiler,234,curveend,heatingcurve end,uint8 (>=20<=90),C,true,number.boiler_heatingcurve_end,number.boiler_curveend -Logamax Plus GB122/Condense 2300,boiler,234,summertemp,summer temperature,uint8 (>=0<=30),C,true,number.boiler_summer_temperature,number.boiler_summertemp +Logamax Plus GB122/Condense 2300,boiler,234,summertemp,summer temperature,uint8 (>=0<=45),C,true,number.boiler_summer_temperature,number.boiler_summertemp Logamax Plus GB122/Condense 2300,boiler,234,nofrostmode,nofrost mode,boolean, ,true,switch.boiler_nofrost_mode,switch.boiler_nofrostmode Logamax Plus GB122/Condense 2300,boiler,234,nofrosttemp,nofrost temperature,uint8 (>=0<=10),C,true,number.boiler_nofrost_temperature,number.boiler_nofrosttemp Logamax Plus GB122/Condense 2300,boiler,234,heatingactivated,heating activated,boolean, ,true,switch.boiler_heating_activated,switch.boiler_heatingactivated @@ -3264,6 +3303,7 @@ Logamax Plus GB122/Condense 2300,boiler,234,heatingpump,heating pump,boolean, ,f Logamax Plus GB122/Condense 2300,boiler,234,pumpmodmax,boiler pump max power,uint8 (>=0<=100),%,true,number.boiler_boiler_pump_max_power,number.boiler_pumpmodmax Logamax Plus GB122/Condense 2300,boiler,234,pumpmodmin,boiler pump min power,uint8 (>=0<=100),%,true,number.boiler_boiler_pump_min_power,number.boiler_pumpmodmin Logamax Plus GB122/Condense 2300,boiler,234,pumpmode,boiler pump mode,enum [proportional\|deltaP-1\|deltaP-2\|deltaP-3\|deltaP-4], ,true,select.boiler_boiler_pump_mode,select.boiler_pumpmode +Logamax Plus GB122/Condense 2300,boiler,234,pumpcharacter,boiler pump characteristic,enum [proportional\|150mbar\|200mbar\|250mbar\|300mbar\|350mbar\|400mbar], ,true,select.boiler_boiler_pump_characteristic,select.boiler_pumpcharacter Logamax Plus GB122/Condense 2300,boiler,234,pumpdelay,pump delay,uint8 (>=0<=60),minutes,true,number.boiler_pump_delay,number.boiler_pumpdelay Logamax Plus GB122/Condense 2300,boiler,234,setflowtemp,set flow temperature,uint8 (>=0<=254),C,false,sensor.boiler_set_flow_temperature,sensor.boiler_setflowtemp Logamax Plus GB122/Condense 2300,boiler,234,setburnpow,burner set power,uint8 (>=0<=100),%,false,sensor.boiler_burner_set_power,sensor.boiler_setburnpow @@ -3285,11 +3325,11 @@ Logamax Plus GB122/Condense 2300,boiler,234,maintenancedate,next maintenance dat Logamax Plus GB122/Condense 2300,boiler,234,emergencyops,emergency operation,boolean, ,true,switch.boiler_emergency_operation,switch.boiler_emergencyops Logamax Plus GB122/Condense 2300,boiler,234,emergencytemp,emergency temperature,uint8 (>=15<=70),C,true,number.boiler_emergency_temperature,number.boiler_emergencytemp Logamax Plus GB122/Condense 2300,boiler,234,meterheat,meter heating,uint24 (>=0<=1677721),kWh,false,sensor.boiler_meter_heating,sensor.boiler_meterheat -Logamax Plus GB122/Condense 2300,boiler,234,meterdhw,meter,uint24 (>=0<=1677721),kWh,false,sensor.boiler_dhw_meter,sensor.boiler_dhw_meterdhw +Logamax Plus GB122/Condense 2300,boiler,234,meter,meter,uint24 (>=0<=1677721),kWh,false,sensor.boiler_dhw_meter,sensor.boiler_dhw_meter Logamax Plus GB122/Condense 2300,boiler,234,gasmeterheat,gas meter heating,uint24 (>=0<=1677721),kWh,false,sensor.boiler_gas_meter_heating,sensor.boiler_gasmeterheat -Logamax Plus GB122/Condense 2300,boiler,234,gasmeterdhw,gas meter,uint24 (>=0<=1677721),kWh,false,sensor.boiler_dhw_gas_meter,sensor.boiler_dhw_gasmeterdhw +Logamax Plus GB122/Condense 2300,boiler,234,gasmeter,gas meter,uint24 (>=0<=1677721),kWh,false,sensor.boiler_dhw_gas_meter,sensor.boiler_dhw_gasmeter Logamax Plus GB122/Condense 2300,boiler,234,nrgheat2,energy heating 2,uint24 (>=0<=1677721),kWh,false,sensor.boiler_energy_heating_2,sensor.boiler_nrgheat2 -Logamax Plus GB122/Condense 2300,boiler,234,nrgdhw2,energy 2,uint24 (>=0<=1677721),kWh,false,sensor.boiler_dhw_energy_2,sensor.boiler_dhw_nrgdhw2 +Logamax Plus GB122/Condense 2300,boiler,234,nrg2,energy 2,uint24 (>=0<=1677721),kWh,false,sensor.boiler_dhw_energy_2,sensor.boiler_dhw_nrg2 Logamax Plus GB122/Condense 2300,boiler,234,tapactivated,turn on/off,boolean, ,true,switch.boiler_dhw_turn_on/off,switch.boiler_dhw_tapactivated Logamax Plus GB122/Condense 2300,boiler,234,settemp,set temperature,uint8 (>=0<=254),C,false,sensor.boiler_dhw_set_temperature,sensor.boiler_dhw_settemp Logamax Plus GB122/Condense 2300,boiler,234,seltemp,selected temperature,uint8 (>=0<=254),C,true,number.boiler_dhw_selected_temperature,number.boiler_dhw_seltemp @@ -3333,7 +3373,7 @@ Logamax Plus GB122/Condense 2300,boiler,234,workm,active time,time (>=0<=1677721 Logamax Plus GB122/Condense 2300,boiler,234,nompower,nominal Power,uint8 (>=0<=254),kW,true,number.boiler_nominal_Power,number.boiler_nompower Logamax Plus GB122/Condense 2300,boiler,234,nrgtotal,total energy,uint24 (>=0<=167772),kWh,false,sensor.boiler_total_energy,sensor.boiler_nrgtotal Logamax Plus GB122/Condense 2300,boiler,234,nrgheat,energy heating,uint24 (>=0<=10000000),kWh,true,number.boiler_energy_heating,number.boiler_nrgheat -Logamax Plus GB122/Condense 2300,boiler,234,nrgdhw,energy,uint24 (>=0<=10000000),kWh,true,number.boiler_dhw_energy,number.boiler_dhw_nrgdhw +Logamax Plus GB122/Condense 2300,boiler,234,nrg,energy,uint24 (>=0<=10000000),kWh,true,number.boiler_dhw_energy,number.boiler_dhw_nrg Logamatic TC100/Moduline Easy,thermostat,202,errorcode,error code,string, ,false,sensor.thermostat_error_code,sensor.thermostat_errorcode Logamatic TC100/Moduline Easy,thermostat,202,lastcode,last error code,string, ,false,sensor.thermostat_last_error_code,sensor.thermostat_lastcode Logamatic TC100/Moduline Easy,thermostat,202,datetime,date/time,string, ,false,sensor.thermostat_date/time,sensor.thermostat_datetime @@ -3541,11 +3581,16 @@ Moduline 400,thermostat,78,seltemp,selected room temperature,int16 (>=0<=30),C,t Moduline 400,thermostat,78,currtemp,current room temperature,int16 (>=-3199<=3199),C,false,sensor.thermostat_hc1_current_room_temperature,sensor.thermostat_hc1_currtemp Moduline 400,thermostat,78,haclimate,mqtt discovery current room temperature,enum [selTemp\|roomTemp] (>=5<=30), ,false,sensor.thermostat_hc1_mqtt_discovery_current_room_temperature,sensor.thermostat_hc1_haclimate Moduline 400,thermostat,78,mode,mode,enum [off\|manual\|auto], ,true,select.thermostat_hc1_mode,select.thermostat_hc1_mode -Moduline 400,thermostat,78,holidays,holiday dates,string, ,true,sensor.thermostat_hc1_holiday_dates,sensor.thermostat_hc1_holidays -Moduline 400,thermostat,78,vacations,vacation dates,string, ,true,sensor.thermostat_hc1_vacation_dates,sensor.thermostat_hc1_vacations -Moduline 400,thermostat,78,program,program,enum [own 1\|family\|morning\|evening\|am\|pm\|midday\|singles\|seniors\|new\|own 2], ,true,select.thermostat_hc1_program,select.thermostat_hc1_program Moduline 400,thermostat,78,pause,pause time,uint8 (>=0<=254),hours,true,number.thermostat_hc1_pause_time,number.thermostat_hc1_pause Moduline 400,thermostat,78,party,party time,uint8 (>=0<=254),hours,true,number.thermostat_hc1_party_time,number.thermostat_hc1_party +Moduline 400,thermostat,78,vacations1,vacation dates 1,string, ,true,sensor.thermostat_hc1_vacation_dates_1,sensor.thermostat_hc1_vacations1 +Moduline 400,thermostat,78,vacations2,vacation dates 2,string, ,true,sensor.thermostat_hc1_vacation_dates_2,sensor.thermostat_hc1_vacations2 +Moduline 400,thermostat,78,vacations3,vacation dates 3,string, ,true,sensor.thermostat_hc1_vacation_dates_3,sensor.thermostat_hc1_vacations3 +Moduline 400,thermostat,78,vacations4,vacation dates 4,string, ,true,sensor.thermostat_hc1_vacation_dates_4,sensor.thermostat_hc1_vacations4 +Moduline 400,thermostat,78,vacations5,vacation dates 5,string, ,true,sensor.thermostat_hc1_vacation_dates_5,sensor.thermostat_hc1_vacations5 +Moduline 400,thermostat,78,vacations6,vacation dates 6,string, ,true,sensor.thermostat_hc1_vacation_dates_6,sensor.thermostat_hc1_vacations6 +Moduline 400,thermostat,78,vacations7,vacation dates 7,string, ,true,sensor.thermostat_hc1_vacation_dates_7,sensor.thermostat_hc1_vacations7 +Moduline 400,thermostat,78,program,program,enum [own 1\|family\|morning\|evening\|am\|pm\|midday\|singles\|seniors\|new\|own 2], ,true,select.thermostat_hc1_program,select.thermostat_hc1_program Moduline 400,thermostat,78,switchtime1,own1 program switchtime,string, ,true,sensor.thermostat_hc1_own1_program_switchtime,sensor.thermostat_hc1_switchtime1 Moduline 400,thermostat,78,heatingtype,heating type,enum [off\|radiator\|convector\|floor], ,true,select.thermostat_hc1_heating_type,select.thermostat_hc1_heatingtype Moduline 400,thermostat,78,controlmode,control mode,enum [outdoor\|room], ,true,select.thermostat_hc1_control_mode,select.thermostat_hc1_controlmode @@ -3561,8 +3606,6 @@ Moduline 400,thermostat,78,whenmodeoff,when thermostat mode off,boolean, ,true,s Moduline 400,thermostat,78,disinfecting,disinfecting,boolean, ,true,switch.thermostat_dhw_disinfecting,switch.thermostat_dhw_disinfecting Moduline 400,thermostat,78,disinfectday,disinfection day,enum [mo\|tu\|we\|th\|fr\|sa\|su\|all], ,true,select.thermostat_dhw_disinfection_day,select.thermostat_dhw_disinfectday Moduline 400,thermostat,78,disinfecthour,disinfection hour,uint8 (>=0<=23), ,true,number.thermostat_dhw_disinfection_hour,number.thermostat_dhw_disinfecthour -Moduline 400,thermostat,78,holidays,holiday dates,string, ,true,sensor.thermostat_dhw_holiday_dates,sensor.thermostat_dhw_holidays -Moduline 400,thermostat,78,vacations,vacation dates,string, ,true,sensor.thermostat_dhw_vacation_dates,sensor.thermostat_dhw_vacations RC10/Moduline 100,thermostat,79,errorcode,error code,string, ,false,sensor.thermostat_error_code,sensor.thermostat_errorcode RC10/Moduline 100,thermostat,79,lastcode,last error code,string, ,false,sensor.thermostat_last_error_code,sensor.thermostat_lastcode RC10/Moduline 100,thermostat,79,intoffset,internal temperature offset,int8 (>=-12<=12),C,true,number.thermostat_internal_temperature_offset,number.thermostat_intoffset @@ -3710,86 +3753,86 @@ RC25,thermostat,151,tempautotemp,temporary set temperature automode,uint8 (>=0<= RC25,thermostat,151,heatingtype,heating type,enum [off\|radiator\|convector\|floor], ,true,select.thermostat_hc1_heating_type,select.thermostat_hc1_heatingtype RC25,thermostat,151,summertemp,summer temperature,uint8 (>=9<=25),C,true,number.thermostat_hc1_summer_temperature,number.thermostat_hc1_summertemp RC25,thermostat,151,summermode,summer mode,enum [winter\|summer], ,false,sensor.thermostat_hc1_summer_mode,sensor.thermostat_hc1_summermode -RC200/CW100,thermostat,157,errorcode,error code,string, ,false,sensor.thermostat_error_code,sensor.thermostat_errorcode -RC200/CW100,thermostat,157,lastcode,last error code,string, ,false,sensor.thermostat_last_error_code,sensor.thermostat_lastcode -RC200/CW100,thermostat,157,datetime,date/time,string, ,true,sensor.thermostat_date/time,sensor.thermostat_datetime -RC200/CW100,thermostat,157,intoffset,internal temperature offset,int8 (>=-12<=12),C,true,number.thermostat_internal_temperature_offset,number.thermostat_intoffset -RC200/CW100,thermostat,157,floordry,floor drying,enum [off\|start\|heat\|hold\|cool\|end], ,false,sensor.thermostat_floor_drying,sensor.thermostat_floordry -RC200/CW100,thermostat,157,dampedoutdoortemp,damped outdoor temperature,int16 (>=-3199<=3199),C,false,sensor.thermostat_damped_outdoor_temperature,sensor.thermostat_dampedoutdoortemp -RC200/CW100,thermostat,157,floordrytemp,floor drying temperature,uint8 (>=0<=254),C,false,sensor.thermostat_floor_drying_temperature,sensor.thermostat_floordrytemp -RC200/CW100,thermostat,157,building,building type,enum [light\|medium\|heavy], ,true,select.thermostat_building_type,select.thermostat_building -RC200/CW100,thermostat,157,minexttemp,minimal external temperature,int8 (>=-126<=126),C,true,number.thermostat_minimal_external_temperature,number.thermostat_minexttemp -RC200/CW100,thermostat,157,damping,damping outdoor temperature,boolean, ,true,switch.thermostat_damping_outdoor_temperature,switch.thermostat_damping -RC200/CW100,thermostat,157,hybridstrategy,hybrid control strategy,enum [co2 optimized\|cost optimized\|outside temp switched\|co2 cost mix], ,true,select.thermostat_hybrid_control_strategy,select.thermostat_hybridstrategy -RC200/CW100,thermostat,157,switchovertemp,outside switchover temperature,int8 (>=-20<=20),C,true,number.thermostat_outside_switchover_temperature,number.thermostat_switchovertemp -RC200/CW100,thermostat,157,energycostratio,energy cost ratio,uint8 (>=0<=20), ,true,number.thermostat_energy_cost_ratio,number.thermostat_energycostratio -RC200/CW100,thermostat,157,fossilefactor,fossile energy factor,uint8 (>=0<=5), ,true,number.thermostat_fossile_energy_factor,number.thermostat_fossilefactor -RC200/CW100,thermostat,157,electricfactor,electric energy factor,uint8 (>=0<=5), ,true,number.thermostat_electric_energy_factor,number.thermostat_electricfactor -RC200/CW100,thermostat,157,delayboiler,delay boiler support,uint8 (>=5<=120),minutes,true,number.thermostat_delay_boiler_support,number.thermostat_delayboiler -RC200/CW100,thermostat,157,tempdiffboiler,temp diff boiler support,uint8 (>=1<=99),C,true,number.thermostat_temp_diff_boiler_support,number.thermostat_tempdiffboiler -RC200/CW100,thermostat,157,pvenabledhw,enable raise dhw,boolean, ,true,switch.thermostat_enable_raise_dhw,switch.thermostat_pvenabledhw -RC200/CW100,thermostat,157,pvraiseheat,raise heating with PV,int8 (>=0<=5),K,true,number.thermostat_raise_heating_with_PV,number.thermostat_pvraiseheat -RC200/CW100,thermostat,157,pvlowercool,lower cooling with PV,int8 (>=-5<=0),K,true,number.thermostat_lower_cooling_with_PV,number.thermostat_pvlowercool -RC200/CW100,thermostat,157,seltemp,selected room temperature,int16 (>=0<=30),C,true,number.thermostat_hc1_selected_room_temperature,number.thermostat_hc1_seltemp -RC200/CW100,thermostat,157,currtemp,current room temperature,int16 (>=-3199<=3199),C,false,sensor.thermostat_hc1_current_room_temperature,sensor.thermostat_hc1_currtemp -RC200/CW100,thermostat,157,haclimate,mqtt discovery current room temperature,enum [selTemp\|roomTemp] (>=5<=30), ,false,sensor.thermostat_hc1_mqtt_discovery_current_room_temperature,sensor.thermostat_hc1_haclimate -RC200/CW100,thermostat,157,mode,mode,enum [manual\|auto], ,true,select.thermostat_hc1_mode,select.thermostat_hc1_mode -RC200/CW100,thermostat,157,modetype,mode type,enum [eco\|comfort], ,false,sensor.thermostat_hc1_mode_type,sensor.thermostat_hc1_modetype -RC200/CW100,thermostat,157,ecotemp,eco temperature,uint8 (>=0<=127),C,true,number.thermostat_hc1_eco_temperature,number.thermostat_hc1_ecotemp -RC200/CW100,thermostat,157,manualtemp,manual temperature,uint8 (>=0<=127),C,true,number.thermostat_hc1_manual_temperature,number.thermostat_hc1_manualtemp -RC200/CW100,thermostat,157,comforttemp,comfort temperature,uint8 (>=0<=127),C,true,number.thermostat_hc1_comfort_temperature,number.thermostat_hc1_comforttemp -RC200/CW100,thermostat,157,summertemp,summer temperature,uint8 (>=10<=30),C,true,number.thermostat_hc1_summer_temperature,number.thermostat_hc1_summertemp -RC200/CW100,thermostat,157,designtemp,design temperature,uint8 (>=0<=254),C,true,number.thermostat_hc1_design_temperature,number.thermostat_hc1_designtemp -RC200/CW100,thermostat,157,offsettemp,offset temperature,int8 (>=-126<=126),C,true,number.thermostat_hc1_offset_temperature,number.thermostat_hc1_offsettemp -RC200/CW100,thermostat,157,minflowtemp,min flow temperature,uint8 (>=0<=254),C,true,number.thermostat_hc1_min_flow_temperature,number.thermostat_hc1_minflowtemp -RC200/CW100,thermostat,157,maxflowtemp,max flow temperature,uint8 (>=0<=254),C,true,number.thermostat_hc1_max_flow_temperature,number.thermostat_hc1_maxflowtemp -RC200/CW100,thermostat,157,roominfluence,room influence,uint8 (>=0<=254),C,true,number.thermostat_hc1_room_influence,number.thermostat_hc1_roominfluence -RC200/CW100,thermostat,157,roominflfactor,room influence factor,uint8 (>=0<=25), ,true,number.thermostat_hc1_room_influence_factor,number.thermostat_hc1_roominflfactor -RC200/CW100,thermostat,157,curroominfl,current room influence,int16 (>=-3199<=3199),C,false,sensor.thermostat_hc1_current_room_influence,sensor.thermostat_hc1_curroominfl -RC200/CW100,thermostat,157,nofrostmode,nofrost mode,enum [room\|outdoor\|room outdoor], ,true,select.thermostat_hc1_nofrost_mode,select.thermostat_hc1_nofrostmode -RC200/CW100,thermostat,157,nofrosttemp,nofrost temperature,int8 (>=-126<=126),C,true,number.thermostat_hc1_nofrost_temperature,number.thermostat_hc1_nofrosttemp -RC200/CW100,thermostat,157,targetflowtemp,target flow temperature,uint8 (>=0<=254),C,false,sensor.thermostat_hc1_target_flow_temperature,sensor.thermostat_hc1_targetflowtemp -RC200/CW100,thermostat,157,heatingtype,heating type,enum [off\|radiator\|convector\|floor], ,true,select.thermostat_hc1_heating_type,select.thermostat_hc1_heatingtype -RC200/CW100,thermostat,157,summersetmode,set summer mode,enum [summer\|auto\|winter], ,true,select.thermostat_hc1_set_summer_mode,select.thermostat_hc1_summersetmode -RC200/CW100,thermostat,157,hpoperatingmode,heatpump operating mode,enum [off\|auto\|heating\|cooling], ,true,select.thermostat_hc1_heatpump_operating_mode,select.thermostat_hc1_hpoperatingmode -RC200/CW100,thermostat,157,summermode,summer mode,enum [winter\|summer], ,false,sensor.thermostat_hc1_summer_mode,sensor.thermostat_hc1_summermode -RC200/CW100,thermostat,157,hpoperatingstate,heatpump operating state,enum [heating\|off\|cooling], ,false,sensor.thermostat_hc1_heatpump_operating_state,sensor.thermostat_hc1_hpoperatingstate -RC200/CW100,thermostat,157,controlmode,control mode,enum [optimized\|simple\|n/a\|room\|power], ,true,select.thermostat_hc1_control_mode,select.thermostat_hc1_controlmode -RC200/CW100,thermostat,157,program,program,enum [prog 1\|prog 2], ,true,select.thermostat_hc1_program,select.thermostat_hc1_program -RC200/CW100,thermostat,157,tempautotemp,temporary set temperature automode,int8 (>=-1<=30),C,true,number.thermostat_hc1_temporary_set_temperature_automode,number.thermostat_hc1_tempautotemp -RC200/CW100,thermostat,157,remoteseltemp,temporary set temperature from remote,int8 (>=-63<=63),C,false,sensor.thermostat_hc1_temporary_set_temperature_from_remote,sensor.thermostat_hc1_remoteseltemp -RC200/CW100,thermostat,157,fastheatup,fast heatup,uint8 (>=0<=100),%,true,number.thermostat_hc1_fast_heatup,number.thermostat_hc1_fastheatup -RC200/CW100,thermostat,157,switchonoptimization,switch-on optimization,boolean, ,true,switch.thermostat_hc1_switch-on_optimization,switch.thermostat_hc1_switchonoptimization -RC200/CW100,thermostat,157,reducemode,reduce mode,enum [outdoor\|room\|reduce], ,true,select.thermostat_hc1_reduce_mode,select.thermostat_hc1_reducemode -RC200/CW100,thermostat,157,noreducetemp,no reduce below temperature,int8 (>=-126<=126),C,true,number.thermostat_hc1_no_reduce_below_temperature,number.thermostat_hc1_noreducetemp -RC200/CW100,thermostat,157,reducetemp,off/reduce switch temperature,int8 (>=-126<=126),C,true,number.thermostat_hc1_off/reduce_switch_temperature,number.thermostat_hc1_reducetemp -RC200/CW100,thermostat,157,dhwprio,dhw priority,boolean, ,true,switch.thermostat_hc1_dhw_priority,switch.thermostat_hc1_dhwprio -RC200/CW100,thermostat,157,cooling,cooling,boolean, ,true,switch.thermostat_hc1_cooling,switch.thermostat_hc1_cooling -RC200/CW100,thermostat,157,coolingon,cooling,boolean, ,false,binary_sensor.thermostat_hc1_cooling,binary_sensor.thermostat_hc1_coolingon -RC200/CW100,thermostat,157,hpmode,HP Mode,enum [heating\|cooling\|heating&cooling], ,true,select.thermostat_hc1_HP_Mode,select.thermostat_hc1_hpmode -RC200/CW100,thermostat,157,dewoffset,dew point offset,uint8 (>=2<=10),K,true,number.thermostat_hc1_dew_point_offset,number.thermostat_hc1_dewoffset -RC200/CW100,thermostat,157,roomtempdiff,room temp difference,uint8 (>=0<=254),K,true,number.thermostat_hc1_room_temp_difference,number.thermostat_hc1_roomtempdiff -RC200/CW100,thermostat,157,hpminflowtemp,HP min. flow temp.,uint8 (>=0<=254),C,true,number.thermostat_hc1_HP_min._flow_temp.,number.thermostat_hc1_hpminflowtemp -RC200/CW100,thermostat,157,control,control device,enum [RC310\|RC200\|RC100\|RC100H\|TC100], ,true,select.thermostat_hc1_control_device,select.thermostat_hc1_control -RC200/CW100,thermostat,157,remotetemp,room temperature from remote,int16 (>=-1<=101),C,true,number.thermostat_hc1_room_temperature_from_remote,number.thermostat_hc1_remotetemp -RC200/CW100,thermostat,157,remotehum,room humidity from remote,uint8 (>=-1<=101),%,true,number.thermostat_hc1_room_humidity_from_remote,number.thermostat_hc1_remotehum -RC200/CW100,thermostat,157,heatondelay,heat-on delay,uint8 (>=1<=48),hours,true,number.thermostat_hc1_heat-on_delay,number.thermostat_hc1_heatondelay -RC200/CW100,thermostat,157,heatoffdelay,heat-off delay,uint8 (>=1<=48),hours,true,number.thermostat_hc1_heat-off_delay,number.thermostat_hc1_heatoffdelay -RC200/CW100,thermostat,157,instantstart,instant start,uint8 (>=1<=10),K,true,number.thermostat_hc1_instant_start,number.thermostat_hc1_instantstart -RC200/CW100,thermostat,157,boost,boost mode,boolean, ,true,switch.thermostat_hc1_boost_mode,switch.thermostat_hc1_boost -RC200/CW100,thermostat,157,boosttime,boost time,uint8 (>=0<=254),hours,true,number.thermostat_hc1_boost_time,number.thermostat_hc1_boosttime -RC200/CW100,thermostat,157,mode,mode,enum [off\|normal\|comfort\|auto\|own prog], ,true,select.thermostat_dhw_mode,select.thermostat_dhw_mode -RC200/CW100,thermostat,157,settemp,set temperature,uint8 (>=0<=254),C,true,number.thermostat_dhw_set_temperature,number.thermostat_dhw_settemp -RC200/CW100,thermostat,157,settemplow,set low temperature,uint8 (>=0<=254),C,true,number.thermostat_dhw_set_low_temperature,number.thermostat_dhw_settemplow -RC200/CW100,thermostat,157,circmode,circulation pump mode,enum [off\|on\|auto\|own prog], ,true,select.thermostat_dhw_circulation_pump_mode,select.thermostat_dhw_circmode -RC200/CW100,thermostat,157,chargeduration,charge duration,uint8 (>=0<=3810),minutes,true,number.thermostat_dhw_charge_duration,number.thermostat_dhw_chargeduration -RC200/CW100,thermostat,157,charge,charge,boolean, ,true,switch.thermostat_dhw_charge,switch.thermostat_dhw_charge -RC200/CW100,thermostat,157,extra,extra,uint8 (>=0<=254),C,false,sensor.thermostat_dhw_extra,sensor.thermostat_dhw_extra -RC200/CW100,thermostat,157,disinfecting,disinfecting,boolean, ,true,switch.thermostat_dhw_disinfecting,switch.thermostat_dhw_disinfecting -RC200/CW100,thermostat,157,disinfectday,disinfection day,enum [mo\|tu\|we\|th\|fr\|sa\|su\|all], ,true,select.thermostat_dhw_disinfection_day,select.thermostat_dhw_disinfectday -RC200/CW100,thermostat,157,disinfecttime,disinfection time,uint8 (>=0<=1431),minutes,true,number.thermostat_dhw_disinfection_time,number.thermostat_dhw_disinfecttime -RC200/CW100,thermostat,157,dailyheating,daily heating,boolean, ,true,switch.thermostat_dhw_daily_heating,switch.thermostat_dhw_dailyheating -RC200/CW100,thermostat,157,dailyheattime,daily heating time,uint8 (>=0<=1431),minutes,true,number.thermostat_dhw_daily_heating_time,number.thermostat_dhw_dailyheattime +RC200/CW100/CR120,thermostat,157,errorcode,error code,string, ,false,sensor.thermostat_error_code,sensor.thermostat_errorcode +RC200/CW100/CR120,thermostat,157,lastcode,last error code,string, ,false,sensor.thermostat_last_error_code,sensor.thermostat_lastcode +RC200/CW100/CR120,thermostat,157,datetime,date/time,string, ,true,sensor.thermostat_date/time,sensor.thermostat_datetime +RC200/CW100/CR120,thermostat,157,intoffset,internal temperature offset,int8 (>=-12<=12),C,true,number.thermostat_internal_temperature_offset,number.thermostat_intoffset +RC200/CW100/CR120,thermostat,157,floordry,floor drying,enum [off\|start\|heat\|hold\|cool\|end], ,false,sensor.thermostat_floor_drying,sensor.thermostat_floordry +RC200/CW100/CR120,thermostat,157,dampedoutdoortemp,damped outdoor temperature,int16 (>=-3199<=3199),C,false,sensor.thermostat_damped_outdoor_temperature,sensor.thermostat_dampedoutdoortemp +RC200/CW100/CR120,thermostat,157,floordrytemp,floor drying temperature,uint8 (>=0<=254),C,false,sensor.thermostat_floor_drying_temperature,sensor.thermostat_floordrytemp +RC200/CW100/CR120,thermostat,157,building,building type,enum [light\|medium\|heavy], ,true,select.thermostat_building_type,select.thermostat_building +RC200/CW100/CR120,thermostat,157,minexttemp,minimal external temperature,int8 (>=-126<=126),C,true,number.thermostat_minimal_external_temperature,number.thermostat_minexttemp +RC200/CW100/CR120,thermostat,157,damping,damping outdoor temperature,boolean, ,true,switch.thermostat_damping_outdoor_temperature,switch.thermostat_damping +RC200/CW100/CR120,thermostat,157,hybridstrategy,hybrid control strategy,enum [co2 optimized\|cost optimized\|outside temp switched\|co2 cost mix], ,true,select.thermostat_hybrid_control_strategy,select.thermostat_hybridstrategy +RC200/CW100/CR120,thermostat,157,switchovertemp,outside switchover temperature,int8 (>=-20<=20),C,true,number.thermostat_outside_switchover_temperature,number.thermostat_switchovertemp +RC200/CW100/CR120,thermostat,157,energycostratio,energy cost ratio,uint8 (>=0<=20), ,true,number.thermostat_energy_cost_ratio,number.thermostat_energycostratio +RC200/CW100/CR120,thermostat,157,fossilefactor,fossile energy factor,uint8 (>=0<=5), ,true,number.thermostat_fossile_energy_factor,number.thermostat_fossilefactor +RC200/CW100/CR120,thermostat,157,electricfactor,electric energy factor,uint8 (>=0<=5), ,true,number.thermostat_electric_energy_factor,number.thermostat_electricfactor +RC200/CW100/CR120,thermostat,157,delayboiler,delay boiler support,uint8 (>=5<=120),minutes,true,number.thermostat_delay_boiler_support,number.thermostat_delayboiler +RC200/CW100/CR120,thermostat,157,tempdiffboiler,temp diff boiler support,uint8 (>=1<=99),C,true,number.thermostat_temp_diff_boiler_support,number.thermostat_tempdiffboiler +RC200/CW100/CR120,thermostat,157,pvenabledhw,enable raise dhw,boolean, ,true,switch.thermostat_enable_raise_dhw,switch.thermostat_pvenabledhw +RC200/CW100/CR120,thermostat,157,pvraiseheat,raise heating with PV,int8 (>=0<=5),K,true,number.thermostat_raise_heating_with_PV,number.thermostat_pvraiseheat +RC200/CW100/CR120,thermostat,157,pvlowercool,lower cooling with PV,int8 (>=-5<=0),K,true,number.thermostat_lower_cooling_with_PV,number.thermostat_pvlowercool +RC200/CW100/CR120,thermostat,157,seltemp,selected room temperature,int16 (>=0<=30),C,true,number.thermostat_hc1_selected_room_temperature,number.thermostat_hc1_seltemp +RC200/CW100/CR120,thermostat,157,currtemp,current room temperature,int16 (>=-3199<=3199),C,false,sensor.thermostat_hc1_current_room_temperature,sensor.thermostat_hc1_currtemp +RC200/CW100/CR120,thermostat,157,haclimate,mqtt discovery current room temperature,enum [selTemp\|roomTemp] (>=5<=30), ,false,sensor.thermostat_hc1_mqtt_discovery_current_room_temperature,sensor.thermostat_hc1_haclimate +RC200/CW100/CR120,thermostat,157,mode,mode,enum [manual\|auto], ,true,select.thermostat_hc1_mode,select.thermostat_hc1_mode +RC200/CW100/CR120,thermostat,157,modetype,mode type,enum [eco\|comfort], ,false,sensor.thermostat_hc1_mode_type,sensor.thermostat_hc1_modetype +RC200/CW100/CR120,thermostat,157,ecotemp,eco temperature,uint8 (>=0<=127),C,true,number.thermostat_hc1_eco_temperature,number.thermostat_hc1_ecotemp +RC200/CW100/CR120,thermostat,157,manualtemp,manual temperature,uint8 (>=0<=127),C,true,number.thermostat_hc1_manual_temperature,number.thermostat_hc1_manualtemp +RC200/CW100/CR120,thermostat,157,comforttemp,comfort temperature,uint8 (>=0<=127),C,true,number.thermostat_hc1_comfort_temperature,number.thermostat_hc1_comforttemp +RC200/CW100/CR120,thermostat,157,summertemp,summer temperature,uint8 (>=10<=30),C,true,number.thermostat_hc1_summer_temperature,number.thermostat_hc1_summertemp +RC200/CW100/CR120,thermostat,157,designtemp,design temperature,uint8 (>=0<=254),C,true,number.thermostat_hc1_design_temperature,number.thermostat_hc1_designtemp +RC200/CW100/CR120,thermostat,157,offsettemp,offset temperature,int8 (>=-126<=126),C,true,number.thermostat_hc1_offset_temperature,number.thermostat_hc1_offsettemp +RC200/CW100/CR120,thermostat,157,minflowtemp,min flow temperature,uint8 (>=0<=254),C,true,number.thermostat_hc1_min_flow_temperature,number.thermostat_hc1_minflowtemp +RC200/CW100/CR120,thermostat,157,maxflowtemp,max flow temperature,uint8 (>=0<=254),C,true,number.thermostat_hc1_max_flow_temperature,number.thermostat_hc1_maxflowtemp +RC200/CW100/CR120,thermostat,157,roominfluence,room influence,uint8 (>=0<=254),C,true,number.thermostat_hc1_room_influence,number.thermostat_hc1_roominfluence +RC200/CW100/CR120,thermostat,157,roominflfactor,room influence factor,uint8 (>=0<=25), ,true,number.thermostat_hc1_room_influence_factor,number.thermostat_hc1_roominflfactor +RC200/CW100/CR120,thermostat,157,curroominfl,current room influence,int16 (>=-3199<=3199),C,false,sensor.thermostat_hc1_current_room_influence,sensor.thermostat_hc1_curroominfl +RC200/CW100/CR120,thermostat,157,nofrostmode,nofrost mode,enum [room\|outdoor\|room outdoor], ,true,select.thermostat_hc1_nofrost_mode,select.thermostat_hc1_nofrostmode +RC200/CW100/CR120,thermostat,157,nofrosttemp,nofrost temperature,int8 (>=-126<=126),C,true,number.thermostat_hc1_nofrost_temperature,number.thermostat_hc1_nofrosttemp +RC200/CW100/CR120,thermostat,157,targetflowtemp,target flow temperature,uint8 (>=0<=254),C,false,sensor.thermostat_hc1_target_flow_temperature,sensor.thermostat_hc1_targetflowtemp +RC200/CW100/CR120,thermostat,157,heatingtype,heating type,enum [off\|radiator\|convector\|floor], ,true,select.thermostat_hc1_heating_type,select.thermostat_hc1_heatingtype +RC200/CW100/CR120,thermostat,157,summersetmode,set summer mode,enum [summer\|auto\|winter], ,true,select.thermostat_hc1_set_summer_mode,select.thermostat_hc1_summersetmode +RC200/CW100/CR120,thermostat,157,hpoperatingmode,heatpump operating mode,enum [off\|auto\|heating\|cooling], ,true,select.thermostat_hc1_heatpump_operating_mode,select.thermostat_hc1_hpoperatingmode +RC200/CW100/CR120,thermostat,157,summermode,summer mode,enum [winter\|summer], ,false,sensor.thermostat_hc1_summer_mode,sensor.thermostat_hc1_summermode +RC200/CW100/CR120,thermostat,157,hpoperatingstate,heatpump operating state,enum [heating\|off\|cooling], ,false,sensor.thermostat_hc1_heatpump_operating_state,sensor.thermostat_hc1_hpoperatingstate +RC200/CW100/CR120,thermostat,157,controlmode,control mode,enum [optimized\|simple\|n/a\|room\|power], ,true,select.thermostat_hc1_control_mode,select.thermostat_hc1_controlmode +RC200/CW100/CR120,thermostat,157,program,program,enum [prog 1\|prog 2], ,true,select.thermostat_hc1_program,select.thermostat_hc1_program +RC200/CW100/CR120,thermostat,157,tempautotemp,temporary set temperature automode,int8 (>=-1<=30),C,true,number.thermostat_hc1_temporary_set_temperature_automode,number.thermostat_hc1_tempautotemp +RC200/CW100/CR120,thermostat,157,remoteseltemp,temporary set temperature from remote,int8 (>=-63<=63),C,false,sensor.thermostat_hc1_temporary_set_temperature_from_remote,sensor.thermostat_hc1_remoteseltemp +RC200/CW100/CR120,thermostat,157,fastheatup,fast heatup,uint8 (>=0<=100),%,true,number.thermostat_hc1_fast_heatup,number.thermostat_hc1_fastheatup +RC200/CW100/CR120,thermostat,157,switchonoptimization,switch-on optimization,boolean, ,true,switch.thermostat_hc1_switch-on_optimization,switch.thermostat_hc1_switchonoptimization +RC200/CW100/CR120,thermostat,157,reducemode,reduce mode,enum [outdoor\|room\|reduce], ,true,select.thermostat_hc1_reduce_mode,select.thermostat_hc1_reducemode +RC200/CW100/CR120,thermostat,157,noreducetemp,no reduce below temperature,int8 (>=-126<=126),C,true,number.thermostat_hc1_no_reduce_below_temperature,number.thermostat_hc1_noreducetemp +RC200/CW100/CR120,thermostat,157,reducetemp,off/reduce switch temperature,int8 (>=-126<=126),C,true,number.thermostat_hc1_off/reduce_switch_temperature,number.thermostat_hc1_reducetemp +RC200/CW100/CR120,thermostat,157,dhwprio,dhw priority,boolean, ,true,switch.thermostat_hc1_dhw_priority,switch.thermostat_hc1_dhwprio +RC200/CW100/CR120,thermostat,157,cooling,cooling,boolean, ,true,switch.thermostat_hc1_cooling,switch.thermostat_hc1_cooling +RC200/CW100/CR120,thermostat,157,coolingon,cooling,boolean, ,false,binary_sensor.thermostat_hc1_cooling,binary_sensor.thermostat_hc1_coolingon +RC200/CW100/CR120,thermostat,157,hpmode,HP Mode,enum [heating\|cooling\|heating&cooling], ,true,select.thermostat_hc1_HP_Mode,select.thermostat_hc1_hpmode +RC200/CW100/CR120,thermostat,157,dewoffset,dew point offset,uint8 (>=2<=10),K,true,number.thermostat_hc1_dew_point_offset,number.thermostat_hc1_dewoffset +RC200/CW100/CR120,thermostat,157,roomtempdiff,room temp difference,uint8 (>=0<=254),K,true,number.thermostat_hc1_room_temp_difference,number.thermostat_hc1_roomtempdiff +RC200/CW100/CR120,thermostat,157,hpminflowtemp,HP min. flow temp.,uint8 (>=0<=254),C,true,number.thermostat_hc1_HP_min._flow_temp.,number.thermostat_hc1_hpminflowtemp +RC200/CW100/CR120,thermostat,157,control,control device,enum [RC310\|RC200\|RC100\|RC100H\|TC100], ,true,select.thermostat_hc1_control_device,select.thermostat_hc1_control +RC200/CW100/CR120,thermostat,157,remotetemp,room temperature from remote,int16 (>=-1<=101),C,true,number.thermostat_hc1_room_temperature_from_remote,number.thermostat_hc1_remotetemp +RC200/CW100/CR120,thermostat,157,remotehum,room humidity from remote,uint8 (>=-1<=101),%,true,number.thermostat_hc1_room_humidity_from_remote,number.thermostat_hc1_remotehum +RC200/CW100/CR120,thermostat,157,heatondelay,heat-on delay,uint8 (>=1<=48),hours,true,number.thermostat_hc1_heat-on_delay,number.thermostat_hc1_heatondelay +RC200/CW100/CR120,thermostat,157,heatoffdelay,heat-off delay,uint8 (>=1<=48),hours,true,number.thermostat_hc1_heat-off_delay,number.thermostat_hc1_heatoffdelay +RC200/CW100/CR120,thermostat,157,instantstart,instant start,uint8 (>=1<=10),K,true,number.thermostat_hc1_instant_start,number.thermostat_hc1_instantstart +RC200/CW100/CR120,thermostat,157,boost,boost mode,boolean, ,true,switch.thermostat_hc1_boost_mode,switch.thermostat_hc1_boost +RC200/CW100/CR120,thermostat,157,boosttime,boost time,uint8 (>=0<=254),hours,true,number.thermostat_hc1_boost_time,number.thermostat_hc1_boosttime +RC200/CW100/CR120,thermostat,157,mode,mode,enum [off\|normal\|comfort\|auto\|own prog], ,true,select.thermostat_dhw_mode,select.thermostat_dhw_mode +RC200/CW100/CR120,thermostat,157,settemp,set temperature,uint8 (>=0<=254),C,true,number.thermostat_dhw_set_temperature,number.thermostat_dhw_settemp +RC200/CW100/CR120,thermostat,157,settemplow,set low temperature,uint8 (>=0<=254),C,true,number.thermostat_dhw_set_low_temperature,number.thermostat_dhw_settemplow +RC200/CW100/CR120,thermostat,157,circmode,circulation pump mode,enum [off\|on\|auto\|own prog], ,true,select.thermostat_dhw_circulation_pump_mode,select.thermostat_dhw_circmode +RC200/CW100/CR120,thermostat,157,chargeduration,charge duration,uint8 (>=0<=3810),minutes,true,number.thermostat_dhw_charge_duration,number.thermostat_dhw_chargeduration +RC200/CW100/CR120,thermostat,157,charge,charge,boolean, ,true,switch.thermostat_dhw_charge,switch.thermostat_dhw_charge +RC200/CW100/CR120,thermostat,157,extra,extra,uint8 (>=0<=254),C,false,sensor.thermostat_dhw_extra,sensor.thermostat_dhw_extra +RC200/CW100/CR120,thermostat,157,disinfecting,disinfecting,boolean, ,true,switch.thermostat_dhw_disinfecting,switch.thermostat_dhw_disinfecting +RC200/CW100/CR120,thermostat,157,disinfectday,disinfection day,enum [mo\|tu\|we\|th\|fr\|sa\|su\|all], ,true,select.thermostat_dhw_disinfection_day,select.thermostat_dhw_disinfectday +RC200/CW100/CR120,thermostat,157,disinfecttime,disinfection time,uint8 (>=0<=1431),minutes,true,number.thermostat_dhw_disinfection_time,number.thermostat_dhw_disinfecttime +RC200/CW100/CR120,thermostat,157,dailyheating,daily heating,boolean, ,true,switch.thermostat_dhw_daily_heating,switch.thermostat_dhw_dailyheating +RC200/CW100/CR120,thermostat,157,dailyheattime,daily heating time,uint8 (>=0<=1431),minutes,true,number.thermostat_dhw_daily_heating_time,number.thermostat_dhw_dailyheattime RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410,thermostat,158,errorcode,error code,string, ,false,sensor.thermostat_error_code,sensor.thermostat_errorcode RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410,thermostat,158,lastcode,last error code,string, ,false,sensor.thermostat_last_error_code,sensor.thermostat_lastcode RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410,thermostat,158,datetime,date/time,string, ,true,sensor.thermostat_date/time,sensor.thermostat_datetime @@ -3960,6 +4003,7 @@ Rego 2000/3000,thermostat,172,floordrytemp,floor drying temperature,uint8 (>=0<= Rego 2000/3000,thermostat,172,building,building type,enum [light\|medium\|heavy], ,true,select.thermostat_building_type,select.thermostat_building Rego 2000/3000,thermostat,172,minexttemp,minimal external temperature,int8 (>=-126<=126),C,true,number.thermostat_minimal_external_temperature,number.thermostat_minexttemp Rego 2000/3000,thermostat,172,damping,damping outdoor temperature,boolean, ,true,switch.thermostat_damping_outdoor_temperature,switch.thermostat_damping +Rego 2000/3000,thermostat,172,vacations,vacation dates,string, ,true,sensor.thermostat_vacation_dates,sensor.thermostat_vacations Rego 2000/3000,thermostat,172,hybridstrategy,hybrid control strategy,enum [co2 optimized\|cost optimized\|outside temp switched\|co2 cost mix], ,true,select.thermostat_hybrid_control_strategy,select.thermostat_hybridstrategy Rego 2000/3000,thermostat,172,switchovertemp,outside switchover temperature,int8 (>=-20<=20),C,true,number.thermostat_outside_switchover_temperature,number.thermostat_switchovertemp Rego 2000/3000,thermostat,172,energycostratio,energy cost ratio,uint8 (>=0<=20), ,true,number.thermostat_energy_cost_ratio,number.thermostat_energycostratio @@ -4710,7 +4754,7 @@ MM10,mixer,69,valvestatus,mixing valve actuator (VC1),int8 (>=-100<=100),%,false MM10,mixer,69,flowsettemp,setpoint flow temperature,uint8 (>=0<=254),C,true,number.mixer_hc1_setpoint_flow_temperature,number.mixer_hc1_flowsettemp MM10,mixer,69,pumpstatus,pump status (PC1),boolean, ,true,switch.mixer_hc1_pump_status_(PC1),switch.mixer_hc1_pumpstatus MM10,mixer,69,activated,activated,boolean, ,true,switch.mixer_hc1_activated,switch.mixer_hc1_activated -MM10,mixer,69,valvesettime,time to set valve,uint8 (>=10<=120),seconds,true,number.mixer_hc1_time_to_set_valve,number.mixer_hc1_valvesettime +MM10,mixer,69,valvesettime,time to set valve,uint8 (>=10<=600),seconds,true,number.mixer_hc1_time_to_set_valve,number.mixer_hc1_valvesettime IPM,mixer,100,flowtemphc,flow temperature (TC1),uint16 (>=0<=3199),C,false,sensor.mixer_hc1_flow_temperature_(TC1),sensor.mixer_hc1_flowtemphc IPM,mixer,100,valvestatus,mixing valve actuator (VC1),uint8 (>=0<=100),%,false,sensor.mixer_hc1_mixing_valve_actuator_(VC1),sensor.mixer_hc1_valvestatus IPM,mixer,100,flowsettemp,setpoint flow temperature,uint8 (>=0<=254),C,true,number.mixer_hc1_setpoint_flow_temperature,number.mixer_hc1_flowsettemp @@ -4981,13 +5025,13 @@ HP Module,heatpump,252,compstartmod,compressor start modulation,uint8 (>=0<=100) HP Module,heatpump,252,heatdrainpan,heat drain pan,boolean, ,true,switch.heatpump_heat_drain_pan,switch.heatpump_heatdrainpan HP Module,heatpump,252,heatcable,heating cable,boolean, ,true,switch.heatpump_heating_cable,switch.heatpump_heatcable HP Module,heatpump,252,nrgtotal,total energy,uint24 (>=0<=167772),kWh,false,sensor.heatpump_total_energy,sensor.heatpump_nrgtotal -HP Module,heatpump,252,nrgdhw,energy,uint24 (>=0<=167772),kWh,false,sensor.heatpump_dhw_energy,sensor.heatpump_dhw_nrgdhw +HP Module,heatpump,252,nrg,energy,uint24 (>=0<=167772),kWh,false,sensor.heatpump_dhw_energy,sensor.heatpump_dhw_nrg HP Module,heatpump,252,nrgheat,energy heating,uint24 (>=0<=167772),kWh,false,sensor.heatpump_energy_heating,sensor.heatpump_nrgheat HP Module,heatpump,252,metertotal,meter total,uint24 (>=0<=167772),kWh,false,sensor.heatpump_meter_total,sensor.heatpump_metertotal HP Module,heatpump,252,metercomp,meter compressor,uint24 (>=0<=167772),kWh,false,sensor.heatpump_meter_compressor,sensor.heatpump_metercomp HP Module,heatpump,252,metereheat,meter e-heater,uint24 (>=0<=167772),kWh,false,sensor.heatpump_meter_e-heater,sensor.heatpump_metereheat HP Module,heatpump,252,meterheat,meter heating,uint24 (>=0<=167772),kWh,false,sensor.heatpump_meter_heating,sensor.heatpump_meterheat -HP Module,heatpump,252,meterdhw,meter,uint24 (>=0<=167772),kWh,false,sensor.heatpump_dhw_meter,sensor.heatpump_dhw_meterdhw +HP Module,heatpump,252,meter,meter,uint24 (>=0<=167772),kWh,false,sensor.heatpump_dhw_meter,sensor.heatpump_dhw_meter Hybrid Manager HM200,heatpump,248,airhumidity,relative air humidity,uint8 (>=0<=100),%,false,sensor.heatpump_relative_air_humidity,sensor.heatpump_airhumidity Hybrid Manager HM200,heatpump,248,dewtemperature,dew point temperature,uint8 (>=0<=254),C,false,sensor.heatpump_dew_point_temperature,sensor.heatpump_dewtemperature Hybrid Manager HM200,heatpump,248,curflowtemp,current flow temperature,int16 (>=-3199<=3199),C,false,sensor.heatpump_current_flow_temperature,sensor.heatpump_curflowtemp @@ -5020,13 +5064,13 @@ Hybrid Manager HM200,heatpump,248,compstartmod,compressor start modulation,uint8 Hybrid Manager HM200,heatpump,248,heatdrainpan,heat drain pan,boolean, ,true,switch.heatpump_heat_drain_pan,switch.heatpump_heatdrainpan Hybrid Manager HM200,heatpump,248,heatcable,heating cable,boolean, ,true,switch.heatpump_heating_cable,switch.heatpump_heatcable Hybrid Manager HM200,heatpump,248,nrgtotal,total energy,uint24 (>=0<=167772),kWh,false,sensor.heatpump_total_energy,sensor.heatpump_nrgtotal -Hybrid Manager HM200,heatpump,248,nrgdhw,energy,uint24 (>=0<=167772),kWh,false,sensor.heatpump_dhw_energy,sensor.heatpump_dhw_nrgdhw +Hybrid Manager HM200,heatpump,248,nrg,energy,uint24 (>=0<=167772),kWh,false,sensor.heatpump_dhw_energy,sensor.heatpump_dhw_nrg Hybrid Manager HM200,heatpump,248,nrgheat,energy heating,uint24 (>=0<=167772),kWh,false,sensor.heatpump_energy_heating,sensor.heatpump_nrgheat Hybrid Manager HM200,heatpump,248,metertotal,meter total,uint24 (>=0<=167772),kWh,false,sensor.heatpump_meter_total,sensor.heatpump_metertotal Hybrid Manager HM200,heatpump,248,metercomp,meter compressor,uint24 (>=0<=167772),kWh,false,sensor.heatpump_meter_compressor,sensor.heatpump_metercomp Hybrid Manager HM200,heatpump,248,metereheat,meter e-heater,uint24 (>=0<=167772),kWh,false,sensor.heatpump_meter_e-heater,sensor.heatpump_metereheat Hybrid Manager HM200,heatpump,248,meterheat,meter heating,uint24 (>=0<=167772),kWh,false,sensor.heatpump_meter_heating,sensor.heatpump_meterheat -Hybrid Manager HM200,heatpump,248,meterdhw,meter,uint24 (>=0<=167772),kWh,false,sensor.heatpump_dhw_meter,sensor.heatpump_dhw_meterdhw +Hybrid Manager HM200,heatpump,248,meter,meter,uint24 (>=0<=167772),kWh,false,sensor.heatpump_dhw_meter,sensor.heatpump_dhw_meter WM10,switch,71,activated,activated,boolean, ,false,binary_sensor.switch_activated,binary_sensor.switch_activated WM10,switch,71,flowtemphc,flow temperature (TC1),uint16 (>=0<=3199),C,false,sensor.switch_flow_temperature_(TC1),sensor.switch_flowtemphc WM10,switch,71,status,status,int8 (>=-126<=126), ,false,sensor.switch_status,sensor.switch_status diff --git a/interface/package.json b/interface/package.json index 34ea919cc..62c205e82 100644 --- a/interface/package.json +++ b/interface/package.json @@ -26,8 +26,8 @@ "@alova/scene-react": "^1.6.1", "@emotion/react": "^11.11.4", "@emotion/styled": "^11.11.5", - "@mui/icons-material": "^5.15.20", - "@mui/material": "^5.15.20", + "@mui/icons-material": "^5.15.21", + "@mui/material": "^5.15.21", "@table-library/react-table-library": "4.1.7", "@types/lodash-es": "^4.17.12", "@types/node": "^20.14.9", @@ -51,13 +51,13 @@ }, "devDependencies": { "@babel/core": "^7.24.7", - "@eslint/js": "^9.5.0", + "@eslint/js": "^9.6.0", "@preact/compat": "^17.1.2", "@preact/preset-vite": "^2.8.3", "@trivago/prettier-plugin-sort-imports": "^4.3.0", "@types/babel__core": "^7", "concurrently": "^8.2.2", - "eslint": "^9.5.0", + "eslint": "^9.6.0", "eslint-config-prettier": "^9.1.0", "preact": "^10.22.0", "prettier": "^3.3.2", diff --git a/interface/yarn.lock b/interface/yarn.lock index fbe4ba642..f07968f2b 100644 --- a/interface/yarn.lock +++ b/interface/yarn.lock @@ -917,14 +917,14 @@ __metadata: languageName: node linkType: hard -"@eslint/config-array@npm:^0.16.0": - version: 0.16.0 - resolution: "@eslint/config-array@npm:0.16.0" +"@eslint/config-array@npm:^0.17.0": + version: 0.17.0 + resolution: "@eslint/config-array@npm:0.17.0" dependencies: "@eslint/object-schema": "npm:^2.1.4" debug: "npm:^4.3.1" - minimatch: "npm:^3.0.5" - checksum: 10c0/b9d04409151dc95ec6b5e04e1e185a808d58e18cfc7340adc1e9420a5ff15843a0a308fb2cd9a2b354652885c2bebbcd5515814e93e9c9133f423891b6e53c70 + minimatch: "npm:^3.1.2" + checksum: 10c0/97eb23ef0948dbc5f24884a3b75c537ca37ee2b1f27a864cd0d9189c089bc1a724dc6e1a4d9b7dd304d9f732ca02aa7916243a7715d6f1f17159d8a8c83f0c9e languageName: node linkType: hard @@ -945,10 +945,10 @@ __metadata: languageName: node linkType: hard -"@eslint/js@npm:9.5.0, @eslint/js@npm:^9.5.0": - version: 9.5.0 - resolution: "@eslint/js@npm:9.5.0" - checksum: 10c0/dacf51ec2d5b4c8d1315d21a0ff761235d9e39b2391cb945138c58dc512a6c18949c40b644235f5c4fdf5b637ef8f881214acc496dddf46b718529bf22af42ac +"@eslint/js@npm:9.6.0, @eslint/js@npm:^9.6.0": + version: 9.6.0 + resolution: "@eslint/js@npm:9.6.0" + checksum: 10c0/83967a7e59f2e958c9bbb3acd0929cad00d59d927ad786ed8e0d30b07f983c6bea3af6f4ad32da32145db40b7a741a816ba339bdd8960fc7fc8231716d943b7f languageName: node linkType: hard @@ -1099,16 +1099,16 @@ __metadata: languageName: node linkType: hard -"@mui/core-downloads-tracker@npm:^5.15.20": - version: 5.15.20 - resolution: "@mui/core-downloads-tracker@npm:5.15.20" - checksum: 10c0/0e1f9aa9c85d5f60fa5937edc22dfbebd512671379e3adb7c99a8ef0928bf42daed98cede41a407e810a225554943675e9d976bc0ae17acdc20445c8d2f121b3 +"@mui/core-downloads-tracker@npm:^5.15.21": + version: 5.15.21 + resolution: "@mui/core-downloads-tracker@npm:5.15.21" + checksum: 10c0/986d03f08253c839f142f15d2ec8f0b889eb802cdd0306e6fbc678b50689d42334bb8e1d85ca46fa7ff5c69a76657a91830e672059341dc7c1fd74b1cd134481 languageName: node linkType: hard -"@mui/icons-material@npm:^5.15.20": - version: 5.15.20 - resolution: "@mui/icons-material@npm:5.15.20" +"@mui/icons-material@npm:^5.15.21": + version: 5.15.21 + resolution: "@mui/icons-material@npm:5.15.21" dependencies: "@babel/runtime": "npm:^7.23.9" peerDependencies: @@ -1118,17 +1118,17 @@ __metadata: peerDependenciesMeta: "@types/react": optional: true - checksum: 10c0/3765340625ad0c5181cffbec1a9a52185e9add4d2eda1f8c3e262b11bf9ca1e8cdf87f67f550b300d8c3c31277b7c8bb38261c964f6180d31b3e928a1dc03315 + checksum: 10c0/28685825504a24aa497715ec519014e780e570d00e8edc8f3423da2cb55b2aa2c44e829429efc9059d82542035e6f121d79a9f503cb6ae19439aca9e5321e959 languageName: node linkType: hard -"@mui/material@npm:^5.15.20": - version: 5.15.20 - resolution: "@mui/material@npm:5.15.20" +"@mui/material@npm:^5.15.21": + version: 5.15.21 + resolution: "@mui/material@npm:5.15.21" dependencies: "@babel/runtime": "npm:^7.23.9" "@mui/base": "npm:5.0.0-beta.40" - "@mui/core-downloads-tracker": "npm:^5.15.20" + "@mui/core-downloads-tracker": "npm:^5.15.21" "@mui/system": "npm:^5.15.20" "@mui/types": "npm:^7.2.14" "@mui/utils": "npm:^5.15.20" @@ -1151,7 +1151,7 @@ __metadata: optional: true "@types/react": optional: true - checksum: 10c0/0882661f83f5b73c06d6402ddd9c0f8e471198b838c4a456db03a5256d8febc688abc41645156d155536106a44bd28798efcfdaec00b665ab91dbd5c9dee83eb + checksum: 10c0/005f8ec036f0742e35c7cf6e3bd6280cd996b416bfdc6ee05ba625d1a62a41bbc077a5244b71eba01016fa0df2b1ba115ef7028c962eed1bdd98108fab024a6e languageName: node linkType: hard @@ -1988,9 +1988,9 @@ __metadata: "@babel/core": "npm:^7.24.7" "@emotion/react": "npm:^11.11.4" "@emotion/styled": "npm:^11.11.5" - "@eslint/js": "npm:^9.5.0" - "@mui/icons-material": "npm:^5.15.20" - "@mui/material": "npm:^5.15.20" + "@eslint/js": "npm:^9.6.0" + "@mui/icons-material": "npm:^5.15.21" + "@mui/material": "npm:^5.15.21" "@preact/compat": "npm:^17.1.2" "@preact/preset-vite": "npm:^2.8.3" "@table-library/react-table-library": "npm:4.1.7" @@ -2004,7 +2004,7 @@ __metadata: alova: "npm:^2.21.3" async-validator: "npm:^4.2.5" concurrently: "npm:^8.2.2" - eslint: "npm:^9.5.0" + eslint: "npm:^9.6.0" eslint-config-prettier: "npm:^9.1.0" history: "npm:^5.3.0" jwt-decode: "npm:^4.0.0" @@ -2054,6 +2054,15 @@ __metadata: languageName: node linkType: hard +"acorn@npm:^8.12.0": + version: 8.12.0 + resolution: "acorn@npm:8.12.0" + bin: + acorn: bin/acorn + checksum: 10c0/a19f9dead009d3b430fa3c253710b47778cdaace15b316de6de93a68c355507bc1072a9956372b6c990cbeeb167d4a929249d0faeb8ae4bb6911d68d53299549 + languageName: node + linkType: hard + "agent-base@npm:^7.0.2, agent-base@npm:^7.1.0, agent-base@npm:^7.1.1": version: 7.1.1 resolution: "agent-base@npm:7.1.1" @@ -3491,15 +3500,15 @@ __metadata: languageName: node linkType: hard -"eslint@npm:^9.5.0": - version: 9.5.0 - resolution: "eslint@npm:9.5.0" +"eslint@npm:^9.6.0": + version: 9.6.0 + resolution: "eslint@npm:9.6.0" dependencies: "@eslint-community/eslint-utils": "npm:^4.2.0" "@eslint-community/regexpp": "npm:^4.6.1" - "@eslint/config-array": "npm:^0.16.0" + "@eslint/config-array": "npm:^0.17.0" "@eslint/eslintrc": "npm:^3.1.0" - "@eslint/js": "npm:9.5.0" + "@eslint/js": "npm:9.6.0" "@humanwhocodes/module-importer": "npm:^1.0.1" "@humanwhocodes/retry": "npm:^0.3.0" "@nodelib/fs.walk": "npm:^1.2.8" @@ -3510,7 +3519,7 @@ __metadata: escape-string-regexp: "npm:^4.0.0" eslint-scope: "npm:^8.0.1" eslint-visitor-keys: "npm:^4.0.0" - espree: "npm:^10.0.1" + espree: "npm:^10.1.0" esquery: "npm:^1.5.0" esutils: "npm:^2.0.2" fast-deep-equal: "npm:^3.1.3" @@ -3531,7 +3540,7 @@ __metadata: text-table: "npm:^0.2.0" bin: eslint: bin/eslint.js - checksum: 10c0/1c83d94ccfd6d97474aaaf463714eba7afa040639ad9191db430d34e9e2851ba14510651de69b52f26ee30611caf0fa4c66b3fb73bb71df6ab10cef5bb44bb32 + checksum: 10c0/82ea5ad3f28aaef89e2a98f4e6df0eae9d4e16ccd6d667c69977042e0b103fa5df98bf16d3df72d1ae77edd8c1dccfdf4afa2a55309aa8081a1bc54af6229826 languageName: node linkType: hard @@ -3546,6 +3555,17 @@ __metadata: languageName: node linkType: hard +"espree@npm:^10.1.0": + version: 10.1.0 + resolution: "espree@npm:10.1.0" + dependencies: + acorn: "npm:^8.12.0" + acorn-jsx: "npm:^5.3.2" + eslint-visitor-keys: "npm:^4.0.0" + checksum: 10c0/52e6feaa77a31a6038f0c0e3fce93010a4625701925b0715cd54a2ae190b3275053a0717db698697b32653788ac04845e489d6773b508d6c2e8752f3c57470a0 + languageName: node + linkType: hard + "esquery@npm:^1.5.0": version: 1.5.0 resolution: "esquery@npm:1.5.0" @@ -5267,7 +5287,7 @@ __metadata: languageName: node linkType: hard -"minimatch@npm:^3.0.5, minimatch@npm:^3.1.1, minimatch@npm:^3.1.2": +"minimatch@npm:^3.1.1, minimatch@npm:^3.1.2": version: 3.1.2 resolution: "minimatch@npm:3.1.2" dependencies: