mirror of
https://github.com/emsesp/EMS-ESP32.git
synced 2025-12-07 16:29:51 +03:00
move heating & tap water active back to EMS-ESP booleans - #515
This commit is contained in:
@@ -96,32 +96,17 @@ void Boiler::register_mqtt_ha_config() {
|
||||
Mqtt::register_mqtt_ha_sensor(F("Warm Water current temperature (extern)"), this->device_type(), "wWCurTmp2", "°C", "mdi:coolant-temperature");
|
||||
Mqtt::register_mqtt_ha_sensor(F("Pump modulation"), this->device_type(), "pumpMod", "%", "mdi:sine-wave");
|
||||
Mqtt::register_mqtt_ha_sensor(F("Heat Pump modulation"), this->device_type(), "pumpMod2", "%", "mdi:sine-wave");
|
||||
Mqtt::register_mqtt_ha_sensor(F("System Pressure"), this->device_type(), "sysPress", "bar", "");
|
||||
}
|
||||
|
||||
// send stuff to the Web UI
|
||||
void Boiler::device_info_web(JsonArray & root) {
|
||||
JsonObject dataElement;
|
||||
|
||||
if (serviceCodeChar_[0] && Helpers::hasValue(serviceCode_)) {
|
||||
dataElement = root.createNestedObject();
|
||||
dataElement["name"] = F("Service Code");
|
||||
char s[12];
|
||||
snprintf_P(s, 12, PSTR("%s (%d)"), serviceCodeChar_, serviceCode_);
|
||||
dataElement["value"] = s;
|
||||
}
|
||||
|
||||
if (Helpers::hasValue(tap_water_active_, EMS_VALUE_BOOL)) {
|
||||
dataElement = root.createNestedObject();
|
||||
dataElement["name"] = F("Hot tap water");
|
||||
dataElement["value"] = tap_water_active_ ? F("running") : F("off");
|
||||
}
|
||||
|
||||
if (Helpers::hasValue(heating_active_, EMS_VALUE_BOOL)) {
|
||||
dataElement = root.createNestedObject();
|
||||
dataElement["name"] = F("Central heating");
|
||||
dataElement["value"] = heating_active_ ? F("active") : F("off");
|
||||
}
|
||||
|
||||
render_value_json(root, "", F("Service code"), serviceCodeChar_, nullptr);
|
||||
render_value_json(root, "", F("Service code number"), serviceCode_, nullptr);
|
||||
render_value_json(root, "", F("Hot tap water"), tap_water_active_, nullptr, EMS_VALUE_BOOL);
|
||||
render_value_json(root, "", F("Central Heating"), heating_active_, nullptr, EMS_VALUE_BOOL);
|
||||
render_value_json(root, "", F("Selected flow temperature"), selFlowTemp_, F_(degrees));
|
||||
render_value_json(root, "", F("Current flow temperature"), curFlowTemp_, F_(degrees), 10);
|
||||
render_value_json(root, "", F("Warm Water selected temperature"), wWSelTemp_, F_(degrees));
|
||||
@@ -130,6 +115,7 @@ void Boiler::device_info_web(JsonArray & root) {
|
||||
render_value_json(root, "", F("Warm Water current temperature (extern)"), wWCurTmp2_, F_(degrees), 10);
|
||||
render_value_json(root, "", F("Pump modulation"), pumpMod_, F_(percent));
|
||||
render_value_json(root, "", F("Heat Pump modulation"), pumpMod2_, F_(percent));
|
||||
render_value_json(root, "", F("System pressure"), sysPress_, F_(bar), 10);
|
||||
}
|
||||
|
||||
bool Boiler::command_info(const char * value, const int8_t id, JsonObject & output) {
|
||||
@@ -141,6 +127,14 @@ bool Boiler::command_info(const char * value, const int8_t id, JsonObject & outp
|
||||
bool Boiler::export_values(JsonObject & output) {
|
||||
char s[10]; // for formatting strings
|
||||
|
||||
if (Helpers::hasValue(heating_active_, EMS_VALUE_BOOL)) {
|
||||
output["heating_active"] = Helpers::render_value(s, heating_active_, EMS_VALUE_BOOL);
|
||||
}
|
||||
|
||||
if (Helpers::hasValue(tap_water_active_, EMS_VALUE_BOOL)) {
|
||||
output["tap_water_active"] = Helpers::render_value(s, tap_water_active_, EMS_VALUE_BOOL);
|
||||
}
|
||||
|
||||
if (Helpers::hasValue(wWComfort_)) {
|
||||
if (wWComfort_ == 0x00) {
|
||||
output["wWComfort"] = "Hot";
|
||||
@@ -360,13 +354,8 @@ bool Boiler::updated_values() {
|
||||
void Boiler::show_values(uuid::console::Shell & shell) {
|
||||
EMSdevice::show_values(shell); // for showing the header
|
||||
|
||||
if (Helpers::hasValue(tap_water_active_, EMS_VALUE_BOOL)) {
|
||||
print_value(shell, 2, F("Hot tap water"), tap_water_active_ ? F("running") : F("off"));
|
||||
}
|
||||
|
||||
if (Helpers::hasValue(heating_active_, EMS_VALUE_BOOL)) {
|
||||
print_value(shell, 2, F("Central heating"), heating_active_ ? F("active") : F("off"));
|
||||
}
|
||||
print_value(shell, 2, F("Hot tap water"), tap_water_active_, nullptr, EMS_VALUE_BOOL);
|
||||
print_value(shell, 2, F("Central heating"), heating_active_, nullptr, EMS_VALUE_BOOL);
|
||||
|
||||
print_value(shell, 2, F("Warm Water activated"), wWActivated_, nullptr, EMS_VALUE_BOOL);
|
||||
if (wWType_ == 0) {
|
||||
@@ -380,11 +369,13 @@ void Boiler::show_values(uuid::console::Shell & shell) {
|
||||
} else if (wWType_ == 4) {
|
||||
print_value(shell, 2, F("Warm Water type"), F("layered buffer"));
|
||||
}
|
||||
|
||||
if (Helpers::hasValue(wWChargeType_, EMS_VALUE_BOOL)) {
|
||||
print_value(shell, 2, F("Warm Water charging type"), wWChargeType_ ? F("3-way valve") : F("charge pump"));
|
||||
}
|
||||
|
||||
print_value(shell, 2, F("Warm Water circulation pump available"), wWCircPump_, nullptr, EMS_VALUE_BOOL);
|
||||
|
||||
if (Helpers::hasValue(wWCircPumpMode_)) {
|
||||
if (wWCircPumpMode_ == 7) {
|
||||
print_value(shell, 2, F("Warm Water circulation pump freq"), F("continuous"));
|
||||
@@ -436,8 +427,8 @@ void Boiler::show_values(uuid::console::Shell & shell) {
|
||||
|
||||
print_value(shell, 2, F("Burner selected max power"), selBurnPow_, F_(percent));
|
||||
print_value(shell, 2, F("Burner current power"), curBurnPow_, F_(percent));
|
||||
print_value(shell, 2, F("Flame current"), flameCurr_, F("uA"), 10);
|
||||
print_value(shell, 2, F("System pressure"), sysPress_, F("bar"), 10);
|
||||
print_value(shell, 2, F("Flame current"), flameCurr_, F_(uA), 10);
|
||||
print_value(shell, 2, F("System pressure"), sysPress_, F_(bar), 10);
|
||||
if (Helpers::hasValue(serviceCode_)) {
|
||||
shell.printfln(F(" System service code: %s (%d)"), serviceCodeChar_, serviceCode_);
|
||||
} else if (serviceCodeChar_[0] != '\0') {
|
||||
@@ -449,10 +440,10 @@ void Boiler::show_values(uuid::console::Shell & shell) {
|
||||
print_value(shell, 2, F("Heating temperature setting on the boiler"), heating_temp_, F_(degrees));
|
||||
print_value(shell, 2, F("Boiler circuit pump modulation max power"), pump_mod_max_, F_(percent));
|
||||
print_value(shell, 2, F("Boiler circuit pump modulation min power"), pump_mod_min_, F_(percent));
|
||||
print_value(shell, 2, F("Boiler circuit pump delay time"), pumpDelay_, F("min"));
|
||||
print_value(shell, 2, F("Boiler circuit pump delay time"), pumpDelay_, F_(min));
|
||||
print_value(shell, 2, F("Boiler temp hysteresis on"), boilTemp_on_, F_(degrees));
|
||||
print_value(shell, 2, F("Boiler temp hysteresis off"), boilTemp_off_, F_(degrees));
|
||||
print_value(shell, 2, F("Boiler burner min period"), burnPeriod_, F("min"));
|
||||
print_value(shell, 2, F("Boiler burner min period"), burnPeriod_, F_(min));
|
||||
print_value(shell, 2, F("Boiler burner min power"), burnPowermin_, F_(percent));
|
||||
print_value(shell, 2, F("Boiler burner max power"), burnPowermax_, F_(percent));
|
||||
|
||||
@@ -490,13 +481,19 @@ void Boiler::show_values(uuid::console::Shell & shell) {
|
||||
void Boiler::check_active() {
|
||||
if ((boilerState_ & 0x09) != (last_boilerState & 0x09)) {
|
||||
char s[5];
|
||||
Mqtt::publish(F("heating_active"), Helpers::render_boolean(s, ((boilerState_ & 0x09) == 0x09)));
|
||||
bool b = ((boilerState_ & 0x09) == 0x09);
|
||||
Mqtt::publish(F("heating_active"), Helpers::render_boolean(s, b));
|
||||
heating_active_ = b ? EMS_VALUE_BOOL_ON : EMS_VALUE_BOOL_OFF;
|
||||
}
|
||||
|
||||
if ((boilerState_ & 0x0A) != (last_boilerState & 0x0A)) {
|
||||
char s[5];
|
||||
Mqtt::publish(F("tapwater_active"), Helpers::render_boolean(s, ((boilerState_ & 0x0A) == 0x0A)));
|
||||
EMSESP::tap_water_active((boilerState_ & 0x0A) == 0x0A);
|
||||
bool b = ((boilerState_ & 0x0A) == 0x0A);
|
||||
Mqtt::publish(F("tapwater_active"), Helpers::render_boolean(s, b));
|
||||
tap_water_active_ = b ? EMS_VALUE_BOOL_ON : EMS_VALUE_BOOL_OFF;
|
||||
EMSESP::tap_water_active(b); // let EMS-ESP know, used in the Shower class
|
||||
}
|
||||
|
||||
last_boilerState = boilerState_;
|
||||
|
||||
/*
|
||||
|
||||
@@ -143,8 +143,8 @@ class Boiler : public EMSdevice {
|
||||
uint8_t setWWPumpPow_ = EMS_VALUE_UINT_NOTSET; // ww pump speed/power?
|
||||
|
||||
// other internal calculated params
|
||||
bool tap_water_active_ = false; // Hot tap water is on/off
|
||||
bool heating_active_ = false; // Central heating is on/off
|
||||
uint8_t tap_water_active_ = EMS_VALUE_BOOL_NOTSET; // Hot tap water is on/off
|
||||
uint8_t heating_active_ = EMS_VALUE_BOOL_NOTSET; // Central heating is on/off
|
||||
uint8_t pumpMod2_ = EMS_VALUE_UINT_NOTSET; // heatpump modulation from 0xE3 (heatpumps)
|
||||
|
||||
bool command_info(const char * value, const int8_t id, JsonObject & output);
|
||||
|
||||
Reference in New Issue