@@ -270,97 +270,101 @@ void showInfo() {
}
myDebug_P(PSTR(""));
myDebug_P(PSTR("%sBoiler stats:%s"), COLOR_BOLD_ON, COLOR_BOLD_OFF);
// version details
myDebug_P(PSTR(" Boiler: %s"), ems_getDeviceDescription(EMS_DEVICE_TYPE_BOILER, buffer_type));
// show boiler stats if connected
if (ems_getBoilerEnabled()) {
myDebug_P(PSTR("%sBoiler stats:%s"), COLOR_BOLD_ON, COLOR_BOLD_OFF);
// active stats
if (ems_getBusConnected()) {
if (EMS_Boiler.tapwaterActive != EMS_VALUE_INT_NOTSET) {
myDebug_P(PSTR(" Hot tap water: %s"), EMS_Boiler.tapwaterActive ? "running" : "off");
// version details
myDebug_P(PSTR(" Boiler: %s"), ems_getDeviceDescription(EMS_DEVICE_TYPE_BOILER, buffer_type));
// active stats
if (ems_getBusConnected()) {
if (EMS_Boiler.tapwaterActive != EMS_VALUE_INT_NOTSET) {
myDebug_P(PSTR(" Hot tap water: %s"), EMS_Boiler.tapwaterActive ? "running" : "off");
}
if (EMS_Boiler.heatingActive != EMS_VALUE_INT_NOTSET) {
myDebug_P(PSTR(" Central heating: %s"), EMS_Boiler.heatingActive ? "active" : "off");
}
}
if (EMS_Boiler.heatingActive != EMS_VALUE_INT_NOTSET) {
myDebug_P(PSTR(" Central heating: %s"), EMS_Boiler.heatingActive ? "active" : "off");
// UBAParameterWW
_renderBoolValue("Warm Water activated", EMS_Boiler.wWActivated);
_renderBoolValue("Warm Water circulation pump available", EMS_Boiler.wWCircPump);
if (EMS_Boiler.wWComfort == EMS_VALUE_UBAParameterWW_wwComfort_Hot) {
myDebug_P(PSTR(" Warm Water comfort setting: Hot"));
} else if (EMS_Boiler.wWComfort == EMS_VALUE_UBAParameterWW_wwComfort_Eco) {
myDebug_P(PSTR(" Warm Water comfort setting: Eco"));
} else if (EMS_Boiler.wWComfort == EMS_VALUE_UBAParameterWW_wwComfort_Intelligent) {
myDebug_P(PSTR(" Warm Water comfort setting: Intelligent"));
}
}
// UBAParameterWW
_renderBoolValue("Warm Water activated", EMS_Boiler.wWActivated);
_renderBoolValue("Warm Water circulation pump available", EMS_Boiler.wWCircPump);
if (EMS_Boiler.wWComfort == EMS_VALUE_UBAParameterWW_wwComfort_Hot) {
myDebug_P(PSTR(" Warm Water comfort setting: Hot"));
} else if (EMS_Boiler.wWComfort == EMS_VALUE_UBAParameterWW_wwComfort_Eco) {
myDebug_P(PSTR(" Warm Water comfort setting: Eco"));
} else if (EMS_Boiler.wWComfort == EMS_VALUE_UBAParameterWW_wwComfort_Intelligent) {
myDebug_P(PSTR(" Warm Water comfort setting: Intelligent"));
}
_renderIntValue("Warm Water selected temperature", "C", EMS_Boiler.wWSelTemp);
_renderIntValue("Warm Water desinfection temperature", "C", EMS_Boiler.wWDesinfectTemp);
_renderIntValue("Warm Water selected temperature", "C", EMS_Boiler.wWSelTemp);
_renderIntValue("Warm Water desinfection temperature", "C", EMS_Boiler.wWDesinfectTemp);
// UBAMonitorWWMessage
_renderUShortValue("Warm Water current temperature", "C", EMS_Boiler.wWCurTmp);
_renderIntValue("Warm Water current tap water flow", "l/min", EMS_Boiler.wWCurFlow, 10);
_renderLongValue("Warm Water # starts", "times", EMS_Boiler.wWStarts);
if (EMS_Boiler.wWWorkM != EMS_VALUE_LONG_NOTSET) {
myDebug_P(PSTR(" Warm Water active time: %d days %d hours %d minutes"),
EMS_Boiler.wWWorkM / 1440,
(EMS_Boiler.wWWorkM % 1440) / 60,
EMS_Boiler.wWWorkM % 60);
}
_renderBoolValue("Warm Water 3-way valve", EMS_Boiler.wWHeat);
// UBAMonitorWWMessage
_renderUShortValue("Warm Water current temperature", "C", EMS_Boiler.wWCurTmp);
_renderIntValue("Warm Water current tap water flow", "l/min", EMS_Boiler.wWCurFlow, 10);
_renderLongValue("Warm Water # starts", "times", EMS_Boiler.wWStarts);
if (EMS_Boiler.wWWorkM != EMS_VALUE_LONG_NOTSET) {
myDebug_P(PSTR(" Warm Water active time: %d days %d hours %d minutes"),
EMS_Boiler.wWWorkM / 1440,
(EMS_Boiler.wWWorkM % 1440) / 60,
EMS_Boiler.wWWorkM % 60);
}
_renderBoolValue("Warm Water 3-way valve", EMS_Boiler.wWHeat);
// UBAMonitorFast
_renderIntValue("Selected flow temperature", "C", EMS_Boiler.selFlowTemp);
_renderUShortValue("Current flow temperature", "C", EMS_Boiler.curFlowTemp);
_renderUShortValue("Return temperature", "C", EMS_Boiler.retTemp);
_renderBoolValue("Gas", EMS_Boiler.burnGas);
_renderBoolValue("Boiler pump", EMS_Boiler.heatPmp);
_renderBoolValue("Fan", EMS_Boiler.fanWork);
_renderBoolValue("Ignition", EMS_Boiler.ignWork);
_renderBoolValue("Circulation pump", EMS_Boiler.wWCirc);
_renderIntValue("Burner selected max power", "%", EMS_Boiler.selBurnPow);
_renderIntValue("Burner current power", "%", EMS_Boiler.curBurnPow);
_renderShortValue("Flame current", "uA", EMS_Boiler.flameCurr);
_renderIntValue("System pressure", "bar", EMS_Boiler.sysPress, 10);
if (EMS_Boiler.serviceCode == EMS_VALUE_USHORT_NOTSET) {
myDebug_P(PSTR(" System service code: %s"), EMS_Boiler.serviceCodeChar);
} else {
myDebug_P(PSTR(" System service code: %s (%d)"), EMS_Boiler.serviceCodeChar, EMS_Boiler.serviceCode);
}
// UBAMonitorFast
_renderIntValue("Selected flow temperature", "C", EMS_Boiler.selFlowTemp);
_renderUShortValue("Current flow temperature", "C", EMS_Boiler.curFlowTemp);
_renderUShortValue("Return temperature", "C", EMS_Boiler.retTemp);
_renderBoolValue("Gas", EMS_Boiler.burnGas);
_renderBoolValue("Boiler pump", EMS_Boiler.heatPmp);
_renderBoolValue("Fan", EMS_Boiler.fanWork);
_renderBoolValue("Ignition", EMS_Boiler.ignWork);
_renderBoolValue("Circulation pump", EMS_Boiler.wWCirc);
_renderIntValue("Burner selected max power", "%", EMS_Boiler.selBurnPow);
_renderIntValue("Burner current power", "%", EMS_Boiler.curBurnPow);
_renderShortValue("Flame current", "uA", EMS_Boiler.flameCurr);
_renderIntValue("System pressure", "bar", EMS_Boiler.sysPress, 10);
if (EMS_Boiler.serviceCode == EMS_VALUE_USHORT_NOTSET) {
myDebug_P(PSTR(" System service code: %s"), EMS_Boiler.serviceCodeChar);
} else {
myDebug_P(PSTR(" System service code: %s (%d)"), EMS_Boiler.serviceCodeChar, EMS_Boiler.serviceCode);
}
// UBAParametersMessage
_renderIntValue("Heating temperature setting on the boiler", "C", EMS_Boiler.heating_temp);
_renderIntValue("Boiler circuit pump modulation max power", "%", EMS_Boiler.pump_mod_max);
_renderIntValue("Boiler circuit pump modulation min power", "%", EMS_Boiler.pump_mod_min);
// UBAParametersMessage
_renderIntValue("Heating temperature setting on the boiler", "C", EMS_Boiler.heating_temp);
_renderIntValue("Boiler circuit pump modulation max power", "%", EMS_Boiler.pump_mod_max);
_renderIntValue("Boiler circuit pump modulation min power", "%", EMS_Boiler.pump_mod_min);
// UBAMonitorSlow
if (EMS_Boiler.extTemp != EMS_VALUE_SHORT_NOTSET) {
_renderShortValue("Outside temperature", "C", EMS_Boiler.extTemp);
}
_renderUShortValue("Boiler temperature", "C", EMS_Boiler.boilTemp);
_renderUShortValue("Exhaust temperature", "C", EMS_Boiler.exhaustTemp);
_renderIntValue("Pump modulation", "%", EMS_Boiler.pumpMod);
_renderLongValue("Burner # starts", "times", EMS_Boiler.burnStarts);
if (EMS_Boiler.burnWorkMin != EMS_VALUE_LONG_NOTSET) {
myDebug_P(PSTR(" Total burner operating time: %d days %d hours %d minutes"),
EMS_Boiler.burnWorkMin / 1440,
(EMS_Boiler.burnWorkMin % 1440) / 60,
EMS_Boiler.burnWorkMin % 60);
}
if (EMS_Boiler.heatWorkMin != EMS_VALUE_LONG_NOTSET) {
myDebug_P(PSTR(" Total heat operating time: %d days %d hours %d minutes"),
EMS_Boiler.heatWorkMin / 1440,
(EMS_Boiler.heatWorkMin % 1440) / 60,
EMS_Boiler.heatWorkMin % 60);
}
if (EMS_Boiler.UBAuptime != EMS_VALUE_LONG_NOTSET) {
myDebug_P(PSTR(" Total UBA working time: %d days %d hours %d minutes"),
EMS_Boiler.UBAuptime / 1440,
(EMS_Boiler.UBAuptime % 1440) / 60,
EMS_Boiler.UBAuptime % 60);
// UBAMonitorSlow
if (EMS_Boiler.extTemp != EMS_VALUE_SHORT_NOTSET) {
_renderShortValue("Outside temperature", "C", EMS_Boiler.extTemp);
}
_renderUShortValue("Boiler temperature", "C", EMS_Boiler.boilTemp);
_renderUShortValue("Exhaust temperature", "C", EMS_Boiler.exhaustTemp);
_renderIntValue("Pump modulation", "%", EMS_Boiler.pumpMod);
_renderLongValue("Burner # starts", "times", EMS_Boiler.burnStarts);
if (EMS_Boiler.burnWorkMin != EMS_VALUE_LONG_NOTSET) {
myDebug_P(PSTR(" Total burner operating time: %d days %d hours %d minutes"),
EMS_Boiler.burnWorkMin / 1440,
(EMS_Boiler.burnWorkMin % 1440) / 60,
EMS_Boiler.burnWorkMin % 60);
}
if (EMS_Boiler.heatWorkMin != EMS_VALUE_LONG_NOTSET) {
myDebug_P(PSTR(" Total heat operating time: %d days %d hours %d minutes"),
EMS_Boiler.heatWorkMin / 1440,
(EMS_Boiler.heatWorkMin % 1440) / 60,
EMS_Boiler.heatWorkMin % 60);
}
if (EMS_Boiler.UBAuptime != EMS_VALUE_LONG_NOTSET) {
myDebug_P(PSTR(" Total UBA working time: %d days %d hours %d minutes"),
EMS_Boiler.UBAuptime / 1440,
(EMS_Boiler.UBAuptime % 1440) / 60,
EMS_Boiler.UBAuptime % 60);
}
}
// For SM10/SM100/SM200 Solar Module