boiler (HP) power reduction #2147

This commit is contained in:
MichaelDvP
2024-10-28 07:31:47 +01:00
parent b6053e9a7c
commit 48ab1abf39
3 changed files with 26 additions and 5 deletions

View File

@@ -555,6 +555,15 @@ Boiler::Boiler(uint8_t device_type, int8_t device_id, uint8_t product_id, const
FL_(pvMaxComp),
DeviceValueUOM::KW,
MAKE_CF_CB(set_pvMaxComp));
register_device_value(DeviceValueTAG::TAG_DEVICE_DATA,
&powerReduction_,
DeviceValueType::UINT8,
DeviceValueNumOp::DV_NUMOP_MUL10,
FL_(powerReduction),
DeviceValueUOM::PERCENT,
MAKE_CF_CB(set_powerReduction),
30,
60);
register_device_value(DeviceValueTAG::TAG_DEVICE_DATA,
&hpSetDiffPress_,
DeviceValueType::UINT8,
@@ -1941,6 +1950,7 @@ void Boiler::process_HpSilentMode(std::shared_ptr<const Telegram> telegram) {
has_update(telegram, silentTo_, 53); // in steps of 15 min
has_update(telegram, pvMaxComp_, 54); // #2062
has_update(telegram, hpshutdown_, 58); // 1 powers off
has_update(telegram, powerReduction_, 64); // 3..6 -> is *10
}
// Boiler(0x08) -B-> All(0x00), ?(0x0488), data: 8E 00 00 00 00 00 01 03
@@ -3154,6 +3164,15 @@ bool Boiler::set_hpPowerLimit(const char * value, const int8_t id) {
return false;
}
bool Boiler::set_powerReduction(const char * value, const int8_t id) {
int v;
if (Helpers::value2number(value, v)) {
write_command(0x484, 64, v / 10, 0x484);
return true;
}
return false;
}
bool Boiler::set_vp_cooling(const char * value, const int8_t id) {
bool v;
if (Helpers::value2bool(value, v)) {

View File

@@ -256,6 +256,7 @@ class Boiler : public EMSdevice {
uint8_t maxHeatDhw_;
uint8_t hpMaxPower_;
uint8_t pvMaxComp_;
uint8_t powerReduction_;
uint8_t pvCooling_;
uint8_t manDefrost_;
@@ -332,7 +333,6 @@ class Boiler : public EMSdevice {
uint8_t delayBoiler_; // minutes
uint8_t tempDiffBoiler_; // relative temperature degrees
*/
void process_UBAFactory(std::shared_ptr<const Telegram> telegram);
void process_UBAParameterWW(std::shared_ptr<const Telegram> telegram);
void process_UBAMonitorFast(std::shared_ptr<const Telegram> telegram);
@@ -482,6 +482,7 @@ class Boiler : public EMSdevice {
bool set_pvMaxComp(const char * value, const int8_t id);
bool set_hpDiffPress(const char * value, const int8_t id);
bool set_hpPowerLimit(const char * value, const int8_t id);
bool set_powerReduction(const char * value, const int8_t id);
bool set_auxLimit(const char * value, const int8_t id);
inline bool set_auxMaxLimit(const char * value, const int8_t id) {

View File

@@ -576,6 +576,7 @@ MAKE_TRANSLATION(gasMeterHeat, "gasmeterheat", "gas meter heating", "Gaszähler
MAKE_TRANSLATION(gasMeterWw, "gasmeter", "gas meter", "Gaszähler", "", "", "licznik gazu", "", "", "", "", "počítadlo plynu", "počítadlo plynu") // TODO translate
MAKE_TRANSLATION(hpCurrPower, "hpcurrpower", "compressor current power", "akt. Kompressorleistung", "", "", "", "", "", "", "", "", "aktuální výkon kompresoru") // TODO translate
MAKE_TRANSLATION(hpPowerLimit, "hppowerlimit", "power limit", "Leistungsgrenze", "", "", "", "", "", "", "", "", "omezení výkonu") // TODO translate
MAKE_TRANSLATION(powerReduction, "powerreduction", "power reduction", "Leistungsverringerung", "", "", "", "", "", "", "", "", "omezení výkonu") // TODO translate
// HIU
MAKE_TRANSLATION(netFlowTemp, "netflowtemp", "heat network flow temp", "Systemvorlauftemperatur", "Netto aanvoertemperatuur", "", "temp. zasilania sieci cieplnej", "", "", "ısıtma şebekesi akış derecesi", "temperatura di mandata della rete di riscaldamento", "teplota prívodu tepelnej siete", "teplota přívodu tepelné sítě") // TODO translate