mirror of
https://github.com/emsesp/EMS-ESP32.git
synced 2025-12-07 00:09:51 +03:00
added log w and more ems+ messages
This commit is contained in:
@@ -103,7 +103,7 @@ static const command_t project_cmds[] PROGMEM = {
|
||||
{true, "tx_mode <n>", "changes Tx logic. 1=EMS generic, 2=EMS+, 3=HT3"},
|
||||
|
||||
{false, "info", "show current values deciphered from the EMS messages"},
|
||||
{false, "log <n | b | t | s | r | j | v | number>", "set logging to none, basic, thermostat, solar module, raw, jabber, verbose or specific type"},
|
||||
{false, "log <n | b | t | s | r | j | v | w [type ID]", "set logging to none, basic, thermostat, solar module, raw, jabber, verbose or watch a specific type"},
|
||||
|
||||
#ifdef TESTS
|
||||
{false, "test <n>", "insert a test telegram on to the EMS bus"},
|
||||
@@ -113,7 +113,7 @@ static const command_t project_cmds[] PROGMEM = {
|
||||
{false, "refresh", "fetch values from the EMS devices"},
|
||||
{false, "devices", "list detected EMS devices"},
|
||||
{false, "queue", "show current Tx queue"},
|
||||
{false, "autodetect [quick]", "detect EMS devices and attempt to automatically set boiler and thermostat types"},
|
||||
{false, "autodetect [scan]", "detect EMS devices and attempt to automatically set boiler and thermostat types"},
|
||||
{false, "send XX ...", "send raw telegram data to EMS bus (XX are hex values)"},
|
||||
{false, "thermostat read <type ID>", "send read request to the thermostat for heating circuit hc 1-4"},
|
||||
{false, "thermostat temp [hc] <degrees>", "set current thermostat temperature"},
|
||||
@@ -230,6 +230,8 @@ void showInfo() {
|
||||
myDebug_P(PSTR(" System logging set to Solar Module only"));
|
||||
} else if (sysLog == EMS_SYS_LOGGING_JABBER) {
|
||||
myDebug_P(PSTR(" System logging set to Jabber"));
|
||||
} else if (sysLog == EMS_SYS_LOGGING_WATCH) {
|
||||
myDebug_P(PSTR(" System logging set to Watch"));
|
||||
} else {
|
||||
myDebug_P(PSTR(" System logging set to None"));
|
||||
}
|
||||
@@ -1228,9 +1230,9 @@ void _showCommands(uint8_t event) {
|
||||
// we set the logging here
|
||||
void TelnetCallback(uint8_t event) {
|
||||
if (event == TELNET_EVENT_CONNECT) {
|
||||
ems_setLogging(EMS_SYS_LOGGING_DEFAULT, true);
|
||||
ems_setLogging(EMS_SYS_LOGGING_DEFAULT);
|
||||
} else if (event == TELNET_EVENT_DISCONNECT) {
|
||||
ems_setLogging(EMS_SYS_LOGGING_NONE, true);
|
||||
ems_setLogging(EMS_SYS_LOGGING_NONE);
|
||||
} else if ((event == TELNET_EVENT_SHOWCMD) || (event == TELNET_EVENT_SHOWSET)) {
|
||||
_showCommands(event);
|
||||
}
|
||||
@@ -1273,19 +1275,19 @@ void TelnetCommandCallback(uint8_t wc, const char * commandLine) {
|
||||
if (strcmp(first_cmd, "autodetect") == 0) {
|
||||
if (wc == 2) {
|
||||
char * second_cmd = _readWord();
|
||||
if (strcmp(second_cmd, "quick") == 0) {
|
||||
ems_clearDeviceList();
|
||||
ems_doReadCommand(EMS_TYPE_UBADevices, EMS_Boiler.device_id);
|
||||
if (strcmp(second_cmd, "scan") == 0) {
|
||||
ems_scanDevices(); // known device scan
|
||||
ok = true;
|
||||
}
|
||||
} else {
|
||||
ems_scanDevices(); // normal known device scan
|
||||
ems_clearDeviceList();
|
||||
ems_doReadCommand(EMS_TYPE_UBADevices, EMS_Boiler.device_id);
|
||||
ok = true;
|
||||
}
|
||||
}
|
||||
|
||||
// logging
|
||||
if ((strcmp(first_cmd, "log") == 0) && (wc == 2)) {
|
||||
if ((strcmp(first_cmd, "log") == 0) && (wc >= 2)) {
|
||||
char * second_cmd = _readWord();
|
||||
if (strcmp(second_cmd, "v") == 0) {
|
||||
ems_setLogging(EMS_SYS_LOGGING_VERBOSE);
|
||||
@@ -1308,6 +1310,9 @@ void TelnetCommandCallback(uint8_t wc, const char * commandLine) {
|
||||
} else if (strcmp(second_cmd, "j") == 0) {
|
||||
ems_setLogging(EMS_SYS_LOGGING_JABBER);
|
||||
ok = true;
|
||||
} else if (strcmp(second_cmd, "w") == 0) {
|
||||
ems_setLogging(EMS_SYS_LOGGING_WATCH, _readHexNumber()); // get type_id
|
||||
ok = true;
|
||||
}
|
||||
}
|
||||
|
||||
|
||||
Reference in New Issue