mirror of
https://github.com/emsesp/EMS-ESP32.git
synced 2025-12-07 16:29:51 +03:00
added log w and more ems+ messages
This commit is contained in:
85
src/ems.cpp
85
src/ems.cpp
@@ -50,6 +50,8 @@ void _process_SetPoints(_EMS_RxTelegram * EMS_RxTelegram);
|
||||
|
||||
// EMS+ specific
|
||||
void _process_UBAOutdoorTemp(_EMS_RxTelegram * EMS_RxTelegram);
|
||||
void _process_UBAMonitorFast2(_EMS_RxTelegram * EMS_RxTelegram);
|
||||
void _process_UBAMonitorSlow2(_EMS_RxTelegram * EMS_RxTelegram);
|
||||
|
||||
// SM10
|
||||
void _process_SM10Monitor(_EMS_RxTelegram * EMS_RxTelegram);
|
||||
@@ -125,6 +127,8 @@ const _EMS_Type EMS_Types[] = {
|
||||
|
||||
// UBA/Boiler EMS+
|
||||
{EMS_TYPE_UBAOutdoorTemp, "UBAOutdoorTemp", _process_UBAOutdoorTemp},
|
||||
{EMS_TYPE_UBAMonitorFast2, "UBAMonitorFast2", _process_UBAMonitorFast2},
|
||||
{EMS_TYPE_UBAMonitorSlow2, "UBAMonitorSlow2", _process_UBAMonitorSlow2},
|
||||
|
||||
// Solar Module devices
|
||||
{EMS_TYPE_SM10Monitor, "SM10Monitor", _process_SM10Monitor},
|
||||
@@ -422,12 +426,9 @@ _EMS_SYS_LOGGING ems_getLogging() {
|
||||
return EMS_Sys_Status.emsLogging;
|
||||
}
|
||||
|
||||
void ems_setLogging(_EMS_SYS_LOGGING loglevel, bool silent) {
|
||||
if (loglevel <= EMS_SYS_LOGGING_JABBER) {
|
||||
void ems_setLogging(_EMS_SYS_LOGGING loglevel, uint16_t type_id) {
|
||||
if (loglevel <= EMS_SYS_LOGGING_WATCH) {
|
||||
EMS_Sys_Status.emsLogging = loglevel;
|
||||
if (silent) {
|
||||
return; // don't print to telnet/serial
|
||||
}
|
||||
|
||||
if (loglevel == EMS_SYS_LOGGING_NONE) {
|
||||
myDebug_P(PSTR("System Logging set to None"));
|
||||
@@ -443,6 +444,9 @@ void ems_setLogging(_EMS_SYS_LOGGING loglevel, bool silent) {
|
||||
myDebug_P(PSTR("System Logging set to Raw mode"));
|
||||
} else if (loglevel == EMS_SYS_LOGGING_JABBER) {
|
||||
myDebug_P(PSTR("System Logging set to Jabber mode"));
|
||||
} else if (loglevel == EMS_SYS_LOGGING_WATCH) {
|
||||
EMS_Sys_Status.emsLogging_typeID = type_id;
|
||||
myDebug_P(PSTR("System Logging set to Watch mode"));
|
||||
}
|
||||
}
|
||||
}
|
||||
@@ -555,14 +559,16 @@ void _debugPrintTelegram(const char * prefix, _EMS_RxTelegram * EMS_RxTelegram,
|
||||
strlcat(output_str, " ", sizeof(output_str)); // add space
|
||||
}
|
||||
|
||||
strlcat(output_str, "(CRC=", sizeof(output_str));
|
||||
strlcat(output_str, _hextoa(data[length - 1], buffer), sizeof(output_str));
|
||||
strlcat(output_str, ")", sizeof(output_str));
|
||||
if (!raw) {
|
||||
strlcat(output_str, "(CRC=", sizeof(output_str));
|
||||
strlcat(output_str, _hextoa(data[length - 1], buffer), sizeof(output_str));
|
||||
strlcat(output_str, ")", sizeof(output_str));
|
||||
|
||||
// print number of data bytes only if its a valid telegram
|
||||
if (data_len) {
|
||||
strlcat(output_str, " #data=", sizeof(output_str));
|
||||
strlcat(output_str, itoa(data_len, buffer, 10), sizeof(output_str));
|
||||
// print number of data bytes only if its a valid telegram
|
||||
if (data_len) {
|
||||
strlcat(output_str, " #data=", sizeof(output_str));
|
||||
strlcat(output_str, itoa(data_len, buffer, 10), sizeof(output_str));
|
||||
}
|
||||
}
|
||||
|
||||
strlcat(output_str, COLOR_RESET, sizeof(output_str));
|
||||
@@ -904,9 +910,12 @@ void ems_parseTelegram(uint8_t * telegram, uint8_t length) {
|
||||
}
|
||||
|
||||
// if we are in raw logging mode then just print out the telegram as it is
|
||||
// or if we're watching a specific type ID show it
|
||||
// but still continue to process it
|
||||
if ((EMS_Sys_Status.emsLogging == EMS_SYS_LOGGING_RAW)) {
|
||||
_debugPrintTelegram("", &EMS_RxTelegram, COLOR_WHITE, true);
|
||||
} else if ((EMS_Sys_Status.emsLogging == EMS_SYS_LOGGING_WATCH) && (EMS_RxTelegram.type == EMS_Sys_Status.emsLogging_typeID)) {
|
||||
_debugPrintTelegram("", &EMS_RxTelegram, COLOR_WHITE, true);
|
||||
}
|
||||
|
||||
// Assume at this point we have something that vaguely resembles a telegram in the format [src] [dest] [type] [offset] [data] [crc]
|
||||
@@ -974,7 +983,6 @@ void _printMessage(_EMS_RxTelegram * EMS_RxTelegram) {
|
||||
|
||||
strlcat(output_str, ", ", sizeof(output_str));
|
||||
|
||||
|
||||
if (EMS_Sys_Status.emsLogging == EMS_SYS_LOGGING_THERMOSTAT) {
|
||||
// only print ones to/from thermostat if logging is set to thermostat only
|
||||
if ((src == EMS_Thermostat.device_id) || (dest == EMS_Thermostat.device_id)) {
|
||||
@@ -1310,6 +1318,42 @@ void _process_UBAMonitorFast(_EMS_RxTelegram * EMS_RxTelegram) {
|
||||
_checkActive();
|
||||
}
|
||||
|
||||
/**
|
||||
* UBAMonitorFast2 - type 0xE4 - central heating monitor
|
||||
*/
|
||||
void _process_UBAMonitorFast2(_EMS_RxTelegram * EMS_RxTelegram) {
|
||||
EMS_Boiler.selFlowTemp = _toByte(6);
|
||||
//EMS_Boiler.curFlowTemp = _toShort(1);
|
||||
//EMS_Boiler.retTemp = _toShort(13);
|
||||
|
||||
EMS_Boiler.burnGas = _bitRead(11, 0);
|
||||
EMS_Boiler.wWHeat = _bitRead(11, 2);
|
||||
|
||||
EMS_Boiler.curBurnPow = _toByte(10);
|
||||
EMS_Boiler.selBurnPow = _toByte(9); // burn power max setting
|
||||
|
||||
// set boiler temp only if we actually have a real value
|
||||
if (_toShort(7) != EMS_VALUE_USHORT_NOTSET) {
|
||||
EMS_Boiler.boilTemp = _toShort(7); // 0x8000 if not available
|
||||
}
|
||||
|
||||
EMS_Boiler.flameCurr = _toShort(19);
|
||||
|
||||
// system pressure. FF means missing
|
||||
//EMS_Boiler.sysPress = _toByte(17); // this is *10
|
||||
|
||||
// read the service code / installation status as appears on the display
|
||||
EMS_Boiler.serviceCodeChar[0] = char(_toByte(4)); // ascii character 1
|
||||
EMS_Boiler.serviceCodeChar[1] = char(_toByte(5)); // ascii character 2
|
||||
EMS_Boiler.serviceCodeChar[2] = '\0'; // null terminate string
|
||||
|
||||
// read error code
|
||||
//EMS_Boiler.serviceCode = _toShort(20);
|
||||
|
||||
// at this point do a quick check to see if the hot water or heating is active
|
||||
_checkActive();
|
||||
}
|
||||
|
||||
/**
|
||||
* UBAMonitorSlow - type 0x19 - central heating monitor part 2 (27 bytes long)
|
||||
* received every 60 seconds
|
||||
@@ -1332,6 +1376,21 @@ void _process_UBAMonitorSlow(_EMS_RxTelegram * EMS_RxTelegram) {
|
||||
EMS_Boiler.switchTemp = _toShort(25);
|
||||
}
|
||||
|
||||
/**
|
||||
* UBAMonitorSlow2 - type 0xE5 - central heating monitor
|
||||
*/
|
||||
void _process_UBAMonitorSlow2(_EMS_RxTelegram * EMS_RxTelegram) {
|
||||
EMS_Boiler.fanWork = _bitRead(2, 2);
|
||||
EMS_Boiler.ignWork = _bitRead(2, 3);
|
||||
EMS_Boiler.heatPmp = _bitRead(2, 5);
|
||||
EMS_Boiler.wWCirc = _bitRead(2, 7);
|
||||
|
||||
EMS_Boiler.burnStarts = _toLong(10);
|
||||
EMS_Boiler.burnWorkMin = _toLong(13);
|
||||
EMS_Boiler.heatWorkMin = _toLong(19);
|
||||
EMS_Boiler.pumpMod = _toByte(25); // or is it switchTemp ?
|
||||
}
|
||||
|
||||
/**
|
||||
* UBAOutdoorTemp - type 0xD1 - external temperature
|
||||
*/
|
||||
|
||||
Reference in New Issue