diff --git a/docs/Modbus-Entity-Registers.md b/docs/Modbus-Entity-Registers.md index b130611ab..16c84a41c 100644 --- a/docs/Modbus-Entity-Registers.md +++ b/docs/Modbus-Entity-Registers.md @@ -62,152 +62,153 @@ uint16 | emergencyops | emergency operation | boolean | | true | DEVICE_DATA | 78 | 1 | 1 | uint8 | emergencytemp | emergency temperature | uint8 (>=15<=70) | C | true | DEVICE_DATA | 79 | 1 | 1 | -| pc0flow | Flow PC0 | int16 | l/h | false | DEVICE_DATA | 80 | 1 | 1 | -| pc1flow | Flow PC1 | int16 | l/h | false | DEVICE_DATA | 81 | 1 | 1 | -| pc1on | PC1 | boolean | | false | DEVICE_DATA | 82 | 1 | 1 | -| pc1rate | PC1 rate | uint8 | % | false | DEVICE_DATA | 83 | 1 | 1 | +| pc0lpm | Flow PC0 | uint16 | l/min | false | DEVICE_DATA | 80 | 1 | 1/10 | +| pc0flow | Flow PC0 | uint16 | l/h | false | DEVICE_DATA | 81 | 1 | 1 | +| pc1flow | Flow PC1 | uint16 | l/h | false | DEVICE_DATA | 82 | 1 | 1 | +| pc1on | PC1 | boolean | | false | DEVICE_DATA | 83 | 1 | 1 | +| pc1rate | PC1 rate | uint8 | % | false | DEVICE_DATA | 84 | 1 | 1 | uint8 -| pumpkickhour | pump kick hour | uint8 (>=0<=23) | hours | true | DEVICE_DATA | 84 | 1 | 1 | -| pumpkickday | pump kick day | enum | | true | DEVICE_DATA | 85 | 1 | 1 | +| pumpkickhour | pump kick hour | uint8 (>=0<=23) | hours | true | DEVICE_DATA | 85 | 1 | 1 | +| pumpkickday | pump kick day | enum | | true | DEVICE_DATA | 86 | 1 | 1 | uint16 -| pumpkickdelay | pump kick delay | uint16 (>=0<=32767) | minutes | true | DEVICE_DATA | 86 | 1 | 1 | -| mandefrost | manual defrost | cmd | | true | DEVICE_DATA | 87 | 1 | 1 | -| nrgtotal | total energy | uint24 | kWh | false | DEVICE_DATA | 88 | 2 | 1/100 | +| pumpkickdelay | pump kick delay | uint16 (>=0<=32767) | minutes | true | DEVICE_DATA | 87 | 1 | 1 | +| mandefrost | manual defrost | cmd | | true | DEVICE_DATA | 88 | 1 | 1 | +| nrgtotal | total energy | uint24 | kWh | false | DEVICE_DATA | 89 | 2 | 1/100 | | dhw.nrg | energy | uint24 | kWh | false | DHW | 0 | 2 | 1/100 | -| nrgheat | energy heating | uint24 | kWh | false | DEVICE_DATA | 90 | 2 | 1/100 | -| nrgcool | energy cooling | uint24 | kWh | false | DEVICE_DATA | 92 | 2 | 1/100 | -| metertotal | meter total | uint24 | kWh | false | DEVICE_DATA | 94 | 2 | 1/100 | -| metercomp | meter compressor | uint24 | kWh | false | DEVICE_DATA | 96 | 2 | 1/100 | -| metereheat | meter e-heater | uint24 | kWh | false | DEVICE_DATA | 98 | 2 | 1/100 | -| meterheat | meter heating | uint24 | kWh | false | DEVICE_DATA | 100 | 2 | 1/100 | -| metercool | meter cooling | uint24 | kWh | false | DEVICE_DATA | 102 | 2 | 1/100 | +| nrgheat | energy heating | uint24 | kWh | false | DEVICE_DATA | 91 | 2 | 1/100 | +| nrgcool | energy cooling | uint24 | kWh | false | DEVICE_DATA | 93 | 2 | 1/100 | +| metertotal | meter total | uint24 | kWh | false | DEVICE_DATA | 95 | 2 | 1/100 | +| metercomp | meter compressor | uint24 | kWh | false | DEVICE_DATA | 97 | 2 | 1/100 | +| metereheat | meter e-heater | uint24 | kWh | false | DEVICE_DATA | 99 | 2 | 1/100 | +| meterheat | meter heating | uint24 | kWh | false | DEVICE_DATA | 101 | 2 | 1/100 | +| metercool | meter cooling | uint24 | kWh | false | DEVICE_DATA | 103 | 2 | 1/100 | | dhw.meter | meter | uint24 | kWh | false | DHW | 2 | 2 | 1/100 | -| uptimetotal | heatpump total uptime | time | minutes | false | DEVICE_DATA | 104 | 2 | 1/60 | -| uptimecontrol | total operating time heat | time | minutes | false | DEVICE_DATA | 106 | 2 | 1/60 | -| uptimecompheating | operating time compressor heating | time | minutes | false | DEVICE_DATA | 108 | 2 | 1/60 | -| uptimecompcooling | operating time compressor cooling | time | minutes | false | DEVICE_DATA | 110 | 2 | 1/60 | +| uptimetotal | heatpump total uptime | time | minutes | false | DEVICE_DATA | 105 | 2 | 1/60 | +| uptimecontrol | total operating time heat | time | minutes | false | DEVICE_DATA | 107 | 2 | 1/60 | +| uptimecompheating | operating time compressor heating | time | minutes | false | DEVICE_DATA | 109 | 2 | 1/60 | +| uptimecompcooling | operating time compressor cooling | time | minutes | false | DEVICE_DATA | 111 | 2 | 1/60 | | dhw.uptimecomp | operating time compressor | time | minutes | false | DHW | 4 | 2 | 1/60 | -| uptimecomppool | operating time compressor pool | time | minutes | false | DEVICE_DATA | 112 | 2 | 1/60 | -| totalcompstarts | total compressor control starts | uint24 | | false | DEVICE_DATA | 114 | 2 | 1 | -| heatingstarts | heating control starts | uint24 | | false | DEVICE_DATA | 116 | 2 | 1 | -| coolingstarts | cooling control starts | uint24 | | false | DEVICE_DATA | 118 | 2 | 1 | +| uptimecomppool | operating time compressor pool | time | minutes | false | DEVICE_DATA | 113 | 2 | 1/60 | +| totalcompstarts | total compressor control starts | uint24 | | false | DEVICE_DATA | 115 | 2 | 1 | +| heatingstarts | heating control starts | uint24 | | false | DEVICE_DATA | 117 | 2 | 1 | +| coolingstarts | cooling control starts | uint24 | | false | DEVICE_DATA | 119 | 2 | 1 | | dhw.startshp | starts hp | uint24 | | false | DHW | 6 | 2 | 1 | -| poolstarts | pool control starts | uint24 | | false | DEVICE_DATA | 120 | 2 | 1 | -| nrgconstotal | total energy consumption | uint24 | kWh | false | DEVICE_DATA | 122 | 2 | 1 | -| nrgconscomptotal | total energy consumption compressor | uint24 | kWh | false | DEVICE_DATA | 124 | 2 | 1 | -| nrgconscompheating | energy consumption compressor heating | uint24 | kWh | false | DEVICE_DATA | 126 | 2 | 1 | +| poolstarts | pool control starts | uint24 | | false | DEVICE_DATA | 121 | 2 | 1 | +| nrgconstotal | total energy consumption | uint24 | kWh | false | DEVICE_DATA | 123 | 2 | 1 | +| nrgconscomptotal | total energy consumption compressor | uint24 | kWh | false | DEVICE_DATA | 125 | 2 | 1 | +| nrgconscompheating | energy consumption compressor heating | uint24 | kWh | false | DEVICE_DATA | 127 | 2 | 1 | | dhw.nrgconscomp | energy consumption compressor | uint24 | kWh | false | DHW | 8 | 2 | 1 | -| nrgconscompcooling | energy consumption compressor cooling | uint24 | kWh | false | DEVICE_DATA | 128 | 2 | 1 | -| nrgconscomppool | energy consumption compressor pool | uint24 | kWh | false | DEVICE_DATA | 130 | 2 | 1 | -| auxelecheatnrgconstotal | total aux elec. heater energy consumption | uint24 | kWh | false | DEVICE_DATA | 132 | 2 | 1 | -| auxelecheatnrgconsheating | aux elec. heater energy consumption heating | uint24 | kWh | false | DEVICE_DATA | 134 | 2 | 1 | +| nrgconscompcooling | energy consumption compressor cooling | uint24 | kWh | false | DEVICE_DATA | 129 | 2 | 1 | +| nrgconscomppool | energy consumption compressor pool | uint24 | kWh | false | DEVICE_DATA | 131 | 2 | 1 | +| auxelecheatnrgconstotal | total aux elec. heater energy consumption | uint24 | kWh | false | DEVICE_DATA | 133 | 2 | 1 | +| auxelecheatnrgconsheating | aux elec. heater energy consumption heating | uint24 | kWh | false | DEVICE_DATA | 135 | 2 | 1 | | dhw.auxelecheatnrgcons | aux elec. heater energy consumption | uint24 | kWh | false | DHW | 10 | 2 | 1 | -| auxelecheatnrgconspool | aux elec. heater energy consumption pool | uint24 | kWh | false | DEVICE_DATA | 136 | 2 | 1 | -| nrgsupptotal | total energy supplied | uint24 | kWh | false | DEVICE_DATA | 138 | 2 | 1 | -| nrgsuppheating | total energy supplied heating | uint24 | kWh | false | DEVICE_DATA | 140 | 2 | 1 | +| auxelecheatnrgconspool | aux elec. heater energy consumption pool | uint24 | kWh | false | DEVICE_DATA | 137 | 2 | 1 | +| nrgsupptotal | total energy supplied | uint24 | kWh | false | DEVICE_DATA | 139 | 2 | 1 | +| nrgsuppheating | total energy supplied heating | uint24 | kWh | false | DEVICE_DATA | 141 | 2 | 1 | | dhw.nrgsupp | total energy warm supplied | uint24 | kWh | false | DHW | 12 | 2 | 1 | -| nrgsuppcooling | total energy supplied cooling | uint24 | kWh | false | DEVICE_DATA | 142 | 2 | 1 | -| nrgsupppool | total energy supplied pool | uint24 | kWh | false | DEVICE_DATA | 144 | 2 | 1 | -| hppower | compressor power output | uint16 | kW | false | DEVICE_DATA | 146 | 1 | 1/10 | +| nrgsuppcooling | total energy supplied cooling | uint24 | kWh | false | DEVICE_DATA | 143 | 2 | 1 | +| nrgsupppool | total energy supplied pool | uint24 | kWh | false | DEVICE_DATA | 145 | 2 | 1 | +| hppower | compressor power output | uint16 | kW | false | DEVICE_DATA | 147 | 1 | 1/10 | uint8 -| hpmaxpower | compressor max power | uint8 (>=0<=0) | % | true | DEVICE_DATA | 147 | 1 | 1 | +| hpmaxpower | compressor max power | uint8 (>=0<=0) | % | true | DEVICE_DATA | 148 | 1 | 1 | uint8 -| pvmaxcomp | pv compressor max power | uint8 (>=0<=0) | kW | true | DEVICE_DATA | 148 | 1 | 1/10 | +| pvmaxcomp | pv compressor max power | uint8 (>=0<=0) | kW | true | DEVICE_DATA | 149 | 1 | 1/10 | uint8 -| powerreduction | power reduction | uint8 (>=30<=60) | % | true | DEVICE_DATA | 149 | 1 | 10 | +| powerreduction | power reduction | uint8 (>=30<=60) | % | true | DEVICE_DATA | 150 | 1 | 10 | uint8 -| hpsetdiffpress | set differential pressure | uint8 (>=150<=750) | mbar | true | DEVICE_DATA | 150 | 1 | 50 | -| hpcompon | hp compressor | boolean | | false | DEVICE_DATA | 151 | 1 | 1 | -| hpactivity | compressor activity | enum | | false | DEVICE_DATA | 152 | 1 | 1 | -| hpbrinepumpspd | brine pump speed | uint8 | % | false | DEVICE_DATA | 153 | 1 | 1 | -| hpswitchvalve | switch valve | boolean | | false | DEVICE_DATA | 154 | 1 | 1 | -| hpcompspd | compressor speed | uint8 | % | false | DEVICE_DATA | 155 | 1 | 1 | -| hptargetspd | compressor target speed | uint8 | % | false | DEVICE_DATA | 156 | 1 | 1 | -| hpcircspd | circulation pump speed | uint8 | % | false | DEVICE_DATA | 157 | 1 | 1 | -| recvalve | receiver valve VR0 | uint8 | % | false | DEVICE_DATA | 158 | 1 | 1 | -| expvalve | expansion valve VR1 | uint8 | % | false | DEVICE_DATA | 159 | 1 | 1 | -| hpbrinein | brine in/evaporator | int16 | C | false | DEVICE_DATA | 160 | 1 | 1/10 | -| hpbrineout | brine out/condenser | int16 | C | false | DEVICE_DATA | 161 | 1 | 1/10 | -| hptc0 | heat carrier return (TC0) | int16 | C | false | DEVICE_DATA | 162 | 1 | 1/10 | -| hptc1 | heat carrier forward (TC1) | int16 | C | false | DEVICE_DATA | 163 | 1 | 1/10 | -| hptc3 | condenser temperature (TC3) | int16 | C | false | DEVICE_DATA | 164 | 1 | 1/10 | -| hptr1 | compressor temperature (TR1) | int16 | C | false | DEVICE_DATA | 165 | 1 | 1/10 | -| hptr3 | refrigerant temperature liquid side (condenser output) (TR3) | int16 | C | false | DEVICE_DATA | 166 | 1 | 1/10 | -| hptr4 | evaporator inlet temperature (TR4) | int16 | C | false | DEVICE_DATA | 167 | 1 | 1/10 | -| hptr5 | compressor inlet temperature (TR5) | int16 | C | false | DEVICE_DATA | 168 | 1 | 1/10 | -| hptr6 | compressor outlet temperature (TR6) | int16 | C | false | DEVICE_DATA | 169 | 1 | 1/10 | -| hptr7 | refrigerant temperature gas side (condenser input) (TR7) | int16 | C | false | DEVICE_DATA | 170 | 1 | 1/10 | -| hptl2 | air inlet temperature (TL2) | int16 | C | false | DEVICE_DATA | 171 | 1 | 1/10 | -| hppl1 | low pressure side temperature (PL1) | int16 | C | false | DEVICE_DATA | 172 | 1 | 1/10 | -| hpph1 | high pressure side temperature (PH1) | int16 | C | false | DEVICE_DATA | 173 | 1 | 1/10 | -| hpta4 | drain pan temp (TA4) | int16 | C | false | DEVICE_DATA | 174 | 1 | 1/10 | -| hptw1 | reservoir temp (TW1) | int16 | C | false | DEVICE_DATA | 175 | 1 | 1/10 | +| hpsetdiffpress | set differential pressure | uint8 (>=150<=750) | mbar | true | DEVICE_DATA | 151 | 1 | 50 | +| hpcompon | hp compressor | boolean | | false | DEVICE_DATA | 152 | 1 | 1 | +| hpactivity | compressor activity | enum | | false | DEVICE_DATA | 153 | 1 | 1 | +| hpbrinepumpspd | brine pump speed | uint8 | % | false | DEVICE_DATA | 154 | 1 | 1 | +| hpswitchvalve | switch valve | boolean | | false | DEVICE_DATA | 155 | 1 | 1 | +| hpcompspd | compressor speed | uint8 | % | false | DEVICE_DATA | 156 | 1 | 1 | +| hptargetspd | compressor target speed | uint8 | % | false | DEVICE_DATA | 157 | 1 | 1 | +| hpcircspd | circulation pump speed | uint8 | % | false | DEVICE_DATA | 158 | 1 | 1 | +| recvalve | receiver valve VR0 | uint8 | % | false | DEVICE_DATA | 159 | 1 | 1 | +| expvalve | expansion valve VR1 | uint8 | % | false | DEVICE_DATA | 160 | 1 | 1 | +| hpbrinein | brine in/evaporator | int16 | C | false | DEVICE_DATA | 161 | 1 | 1/10 | +| hpbrineout | brine out/condenser | int16 | C | false | DEVICE_DATA | 162 | 1 | 1/10 | +| hptc0 | heat carrier return (TC0) | int16 | C | false | DEVICE_DATA | 163 | 1 | 1/10 | +| hptc1 | heat carrier forward (TC1) | int16 | C | false | DEVICE_DATA | 164 | 1 | 1/10 | +| hptc3 | condenser temperature (TC3) | int16 | C | false | DEVICE_DATA | 165 | 1 | 1/10 | +| hptr1 | compressor temperature (TR1) | int16 | C | false | DEVICE_DATA | 166 | 1 | 1/10 | +| hptr3 | refrigerant temperature liquid side (condenser output) (TR3) | int16 | C | false | DEVICE_DATA | 167 | 1 | 1/10 | +| hptr4 | evaporator inlet temperature (TR4) | int16 | C | false | DEVICE_DATA | 168 | 1 | 1/10 | +| hptr5 | compressor inlet temperature (TR5) | int16 | C | false | DEVICE_DATA | 169 | 1 | 1/10 | +| hptr6 | compressor outlet temperature (TR6) | int16 | C | false | DEVICE_DATA | 170 | 1 | 1/10 | +| hptr7 | refrigerant temperature gas side (condenser input) (TR7) | int16 | C | false | DEVICE_DATA | 171 | 1 | 1/10 | +| hptl2 | air inlet temperature (TL2) | int16 | C | false | DEVICE_DATA | 172 | 1 | 1/10 | +| hppl1 | low pressure side temperature (PL1) | int16 | C | false | DEVICE_DATA | 173 | 1 | 1/10 | +| hpph1 | high pressure side temperature (PH1) | int16 | C | false | DEVICE_DATA | 174 | 1 | 1/10 | +| hpta4 | drain pan temp (TA4) | int16 | C | false | DEVICE_DATA | 175 | 1 | 1/10 | +| hptw1 | reservoir temp (TW1) | int16 | C | false | DEVICE_DATA | 176 | 1 | 1/10 | uint8 -| poolsettemp | pool set temperature | uint8 (>=0<=0) | C | true | DEVICE_DATA | 176 | 1 | 1/2 | -| hp4way | 4-way valve (VR4) | boolean | | false | DEVICE_DATA | 177 | 1 | 1 | -| hpin1 | input 1 state | boolean | | false | DEVICE_DATA | 178 | 1 | 1 | -| hpin1opt | input 1 options | string | | true | DEVICE_DATA | 179 | 8 | 1 | -| hpin2 | input 2 state | boolean | | false | DEVICE_DATA | 187 | 1 | 1 | -| hpin2opt | input 2 options | string | | true | DEVICE_DATA | 188 | 8 | 1 | -| hpin3 | input 3 state | boolean | | false | DEVICE_DATA | 196 | 1 | 1 | -| hpin3opt | input 3 options | string | | true | DEVICE_DATA | 197 | 8 | 1 | -| hpin4 | input 4 state | boolean | | false | DEVICE_DATA | 205 | 1 | 1 | -| hpin4opt | input 4 options | string | | true | DEVICE_DATA | 206 | 8 | 1 | -| maxheatcomp | heat limit compressor | enum | | true | DEVICE_DATA | 214 | 1 | 1 | -| maxheatheat | heat limit heating | enum | | true | DEVICE_DATA | 215 | 1 | 1 | +| poolsettemp | pool set temperature | uint8 (>=0<=0) | C | true | DEVICE_DATA | 177 | 1 | 1/2 | +| hp4way | 4-way valve (VR4) | boolean | | false | DEVICE_DATA | 178 | 1 | 1 | +| hpin1 | input 1 state | boolean | | false | DEVICE_DATA | 179 | 1 | 1 | +| hpin1opt | input 1 options | string | | true | DEVICE_DATA | 180 | 8 | 1 | +| hpin2 | input 2 state | boolean | | false | DEVICE_DATA | 188 | 1 | 1 | +| hpin2opt | input 2 options | string | | true | DEVICE_DATA | 189 | 8 | 1 | +| hpin3 | input 3 state | boolean | | false | DEVICE_DATA | 197 | 1 | 1 | +| hpin3opt | input 3 options | string | | true | DEVICE_DATA | 198 | 8 | 1 | +| hpin4 | input 4 state | boolean | | false | DEVICE_DATA | 206 | 1 | 1 | +| hpin4opt | input 4 options | string | | true | DEVICE_DATA | 207 | 8 | 1 | +| maxheatcomp | heat limit compressor | enum | | true | DEVICE_DATA | 215 | 1 | 1 | +| maxheatheat | heat limit heating | enum | | true | DEVICE_DATA | 216 | 1 | 1 | | dhw.maxheat | heat limit | enum | | true | DHW | 14 | 1 | 1 | -| auxheatersource | aux heater source | enum | | true | DEVICE_DATA | 216 | 1 | 1 | -| pvcooling | cooling only with PV | boolean | | true | DEVICE_DATA | 217 | 1 | 1 | -| auxheateronly | aux heater only | boolean | | true | DEVICE_DATA | 218 | 1 | 1 | -| auxheateroff | disable aux heater | boolean | | true | DEVICE_DATA | 219 | 1 | 1 | -| auxheaterstatus | aux heater status | enum | | false | DEVICE_DATA | 220 | 1 | 1 | -| auxheaterlevel | aux heater level | uint8 | % | false | DEVICE_DATA | 221 | 1 | 1 | +| auxheatersource | aux heater source | enum | | true | DEVICE_DATA | 217 | 1 | 1 | +| pvcooling | cooling only with PV | boolean | | true | DEVICE_DATA | 218 | 1 | 1 | +| auxheateronly | aux heater only | boolean | | true | DEVICE_DATA | 219 | 1 | 1 | +| auxheateroff | disable aux heater | boolean | | true | DEVICE_DATA | 220 | 1 | 1 | +| auxheaterstatus | aux heater status | enum | | false | DEVICE_DATA | 221 | 1 | 1 | +| auxheaterlevel | aux heater level | uint8 | % | false | DEVICE_DATA | 222 | 1 | 1 | uint16 -| auxheaterdelay | aux heater on delay | uint16 (>=10<=1000) | K*min | true | DEVICE_DATA | 222 | 1 | 10 | +| auxheaterdelay | aux heater on delay | uint16 (>=10<=1000) | K*min | true | DEVICE_DATA | 223 | 1 | 10 | uint8 -| auxmaxlimit | aux heater max limit | uint8 (>=0<=10) | K | true | DEVICE_DATA | 223 | 1 | 1/10 | +| auxmaxlimit | aux heater max limit | uint8 (>=0<=10) | K | true | DEVICE_DATA | 224 | 1 | 1/10 | uint8 -| auxlimitstart | aux heater limit start | uint8 (>=0<=10) | K | true | DEVICE_DATA | 224 | 1 | 1/10 | -| auxheatrmode | aux heater mode | enum | | true | DEVICE_DATA | 225 | 1 | 1 | +| auxlimitstart | aux heater limit start | uint8 (>=0<=10) | K | true | DEVICE_DATA | 225 | 1 | 1/10 | +| auxheatrmode | aux heater mode | enum | | true | DEVICE_DATA | 226 | 1 | 1 | uint16 -| hphystheat | on/off hyst heat | uint16 (>=50<=1500) | K*min | true | DEVICE_DATA | 226 | 1 | 5 | +| hphystheat | on/off hyst heat | uint16 (>=50<=1500) | K*min | true | DEVICE_DATA | 227 | 1 | 5 | uint16 -| hphystcool | on/off hyst cool | uint16 (>=50<=1500) | K*min | true | DEVICE_DATA | 227 | 1 | 5 | +| hphystcool | on/off hyst cool | uint16 (>=50<=1500) | K*min | true | DEVICE_DATA | 228 | 1 | 5 | uint16 -| hphystpool | on/off hyst pool | uint16 (>=50<=1500) | K*min | true | DEVICE_DATA | 228 | 1 | 5 | -| silentmode | silent mode | enum | | true | DEVICE_DATA | 229 | 1 | 1 | +| hphystpool | on/off hyst pool | uint16 (>=50<=1500) | K*min | true | DEVICE_DATA | 229 | 1 | 5 | +| silentmode | silent mode | enum | | true | DEVICE_DATA | 230 | 1 | 1 | uint8 -| silentfrom | silent mode from | uint8 (>=0<=0) | minutes | true | DEVICE_DATA | 230 | 1 | 15 | +| silentfrom | silent mode from | uint8 (>=0<=0) | minutes | true | DEVICE_DATA | 231 | 1 | 15 | uint8 -| silentto | silent mode to | uint8 (>=0<=0) | minutes | true | DEVICE_DATA | 231 | 1 | 15 | +| silentto | silent mode to | uint8 (>=0<=0) | minutes | true | DEVICE_DATA | 232 | 1 | 15 | int8 -| mintempsilent | min outside temp for silent mode | int8 (>=0<=0) | C | true | DEVICE_DATA | 232 | 1 | 1 | +| mintempsilent | min outside temp for silent mode | int8 (>=0<=0) | C | true | DEVICE_DATA | 233 | 1 | 1 | int8 -| tempparmode | outside temp parallel mode | int8 (>=0<=0) | C | true | DEVICE_DATA | 233 | 1 | 1 | -| auxheatmix | aux heater mixing valve | int8 | % | false | DEVICE_DATA | 234 | 1 | 1 | +| tempparmode | outside temp parallel mode | int8 (>=0<=0) | C | true | DEVICE_DATA | 234 | 1 | 1 | +| auxheatmix | aux heater mixing valve | int8 | % | false | DEVICE_DATA | 235 | 1 | 1 | uint8 -| tempdiffheat | temp diff TC3/TC0 heat | uint8 (>=2<=10) | K | true | DEVICE_DATA | 235 | 1 | 1/10 | +| tempdiffheat | temp diff TC3/TC0 heat | uint8 (>=2<=10) | K | true | DEVICE_DATA | 236 | 1 | 1/10 | uint8 -| tempdiffcool | temp diff TC3/TC0 cool | uint8 (>=2<=10) | K | true | DEVICE_DATA | 236 | 1 | 1/10 | -| vpcooling | valve/pump cooling | boolean | | true | DEVICE_DATA | 237 | 1 | 1 | -| heatcable | heating cable | boolean | | true | DEVICE_DATA | 238 | 1 | 1 | -| vc0valve | VC0 valve | boolean | | true | DEVICE_DATA | 239 | 1 | 1 | -| primepump | primary heatpump | boolean | | true | DEVICE_DATA | 240 | 1 | 1 | +| tempdiffcool | temp diff TC3/TC0 cool | uint8 (>=2<=10) | K | true | DEVICE_DATA | 237 | 1 | 1/10 | +| vpcooling | valve/pump cooling | boolean | | true | DEVICE_DATA | 238 | 1 | 1 | +| heatcable | heating cable | boolean | | true | DEVICE_DATA | 239 | 1 | 1 | +| vc0valve | VC0 valve | boolean | | true | DEVICE_DATA | 240 | 1 | 1 | +| primepump | primary heatpump | boolean | | true | DEVICE_DATA | 241 | 1 | 1 | uint8 -| primepumpmod | primary heatpump modulation | uint8 (>=0<=0) | % | true | DEVICE_DATA | 241 | 1 | 1 | -| hp3way | 3-way valve | boolean | | true | DEVICE_DATA | 242 | 1 | 1 | -| elheatstep1 | el. heater step 1 | boolean | | true | DEVICE_DATA | 243 | 1 | 1 | -| elheatstep2 | el. heater step 2 | boolean | | true | DEVICE_DATA | 244 | 1 | 1 | -| elheatstep3 | el. heater step 3 | boolean | | true | DEVICE_DATA | 245 | 1 | 1 | -| hpea0 | condensate reservoir heating (EA0) | boolean | | false | DEVICE_DATA | 246 | 1 | 1 | -| hppumpmode | primary heatpump mode | enum | | true | DEVICE_DATA | 247 | 1 | 1 | +| primepumpmod | primary heatpump modulation | uint8 (>=0<=0) | % | true | DEVICE_DATA | 242 | 1 | 1 | +| hp3way | 3-way valve | boolean | | true | DEVICE_DATA | 243 | 1 | 1 | +| elheatstep1 | el. heater step 1 | boolean | | true | DEVICE_DATA | 244 | 1 | 1 | +| elheatstep2 | el. heater step 2 | boolean | | true | DEVICE_DATA | 245 | 1 | 1 | +| elheatstep3 | el. heater step 3 | boolean | | true | DEVICE_DATA | 246 | 1 | 1 | +| hpea0 | condensate reservoir heating (EA0) | boolean | | false | DEVICE_DATA | 247 | 1 | 1 | +| hppumpmode | primary heatpump mode | enum | | true | DEVICE_DATA | 248 | 1 | 1 | uint8 -| fan | fan | uint8 (>=20<=100) | % | true | DEVICE_DATA | 248 | 1 | 1 | -| fanspd | fan speed | uint8 | % | false | DEVICE_DATA | 249 | 1 | 1 | -| shutdown | shutdown | cmd | | true | DEVICE_DATA | 250 | 1 | 1 | -| hpcurrpower | compressor current power | uint16 | W | false | DEVICE_DATA | 251 | 1 | 1 | +| fan | fan | uint8 (>=20<=100) | % | true | DEVICE_DATA | 249 | 1 | 1 | +| fanspd | fan speed | uint8 | % | false | DEVICE_DATA | 250 | 1 | 1 | +| shutdown | shutdown | cmd | | true | DEVICE_DATA | 251 | 1 | 1 | +| hpcurrpower | compressor current power | uint16 | W | false | DEVICE_DATA | 252 | 1 | 1 | uint16 -| hppowerlimit | power limit | uint16 (>=0<=0) | W | true | DEVICE_DATA | 252 | 1 | 1 | +| hppowerlimit | power limit | uint16 (>=0<=0) | W | true | DEVICE_DATA | 253 | 1 | 1 | | dhw.alternatingop | alternating operation | boolean | | true | DHW | 15 | 1 | 1 | uint8 | dhw.altopprioheat | prioritise heating during dhw | uint8 (>=20<=120) | minutes | true | DHW | 16 | 1 | 1 | @@ -303,39 +304,39 @@ uint8 | syspress | system pressure | uint8 | bar | false | DEVICE_DATA | 11 | 1 | 1/10 | | boiltemp | actual boiler temperature | uint16 | C | false | DEVICE_DATA | 12 | 1 | 1/10 | | headertemp | low loss header | uint16 | C | false | DEVICE_DATA | 13 | 1 | 1/10 | -| exhausttemp | exhaust temperature | uint16 | C | false | DEVICE_DATA | 253 | 1 | 1/10 | -| burngas | gas | boolean | | false | DEVICE_DATA | 254 | 1 | 1 | -| burngas2 | gas stage 2 | boolean | | false | DEVICE_DATA | 255 | 1 | 1 | -| flamecurr | flame current | uint16 | µA | false | DEVICE_DATA | 256 | 1 | 1/10 | -| fanwork | fan | boolean | | false | DEVICE_DATA | 257 | 1 | 1 | -| ignwork | ignition | boolean | | false | DEVICE_DATA | 258 | 1 | 1 | -| oilpreheat | oil preheating | boolean | | false | DEVICE_DATA | 259 | 1 | 1 | +| exhausttemp | exhaust temperature | uint16 | C | false | DEVICE_DATA | 254 | 1 | 1/10 | +| burngas | gas | boolean | | false | DEVICE_DATA | 255 | 1 | 1 | +| burngas2 | gas stage 2 | boolean | | false | DEVICE_DATA | 256 | 1 | 1 | +| flamecurr | flame current | uint16 | µA | false | DEVICE_DATA | 257 | 1 | 1/10 | +| fanwork | fan | boolean | | false | DEVICE_DATA | 258 | 1 | 1 | +| ignwork | ignition | boolean | | false | DEVICE_DATA | 259 | 1 | 1 | +| oilpreheat | oil preheating | boolean | | false | DEVICE_DATA | 260 | 1 | 1 | uint8 -| burnminpower | burner min power | uint8 (>=0<=0) | % | true | DEVICE_DATA | 260 | 1 | 1 | +| burnminpower | burner min power | uint8 (>=0<=0) | % | true | DEVICE_DATA | 261 | 1 | 1 | uint8 -| burnmaxpower | burner max power | uint8 (>=0<=254) | % | true | DEVICE_DATA | 261 | 1 | 1 | +| burnmaxpower | burner max power | uint8 (>=0<=254) | % | true | DEVICE_DATA | 262 | 1 | 1 | uint8 -| burnminperiod | burner min period | uint8 (>=0<=120) | minutes | true | DEVICE_DATA | 262 | 1 | 1 | -| absburnpow | burner current power (absolute) | uint8 | % | false | DEVICE_DATA | 263 | 1 | 1 | -| heatblock | Heatblock temperature | uint16 | C | false | DEVICE_DATA | 264 | 1 | 1/10 | +| burnminperiod | burner min period | uint8 (>=0<=120) | minutes | true | DEVICE_DATA | 263 | 1 | 1 | +| absburnpow | burner current power (absolute) | uint8 | % | false | DEVICE_DATA | 264 | 1 | 1 | +| heatblock | Heatblock temperature | uint16 | C | false | DEVICE_DATA | 265 | 1 | 1/10 | int8 -| boilhyston | hysteresis on temperature | int8 (>=-20<=0) | C | true | DEVICE_DATA | 265 | 1 | 1 | +| boilhyston | hysteresis on temperature | int8 (>=-20<=0) | C | true | DEVICE_DATA | 266 | 1 | 1 | int8 -| boilhystoff | hysteresis off temperature | int8 (>=0<=20) | C | true | DEVICE_DATA | 266 | 1 | 1 | +| boilhystoff | hysteresis off temperature | int8 (>=0<=20) | C | true | DEVICE_DATA | 267 | 1 | 1 | int8 -| boil2hyston | hysteresis stage 2 on temperature | int8 (>=-20<=0) | C | true | DEVICE_DATA | 267 | 1 | 1 | +| boil2hyston | hysteresis stage 2 on temperature | int8 (>=-20<=0) | C | true | DEVICE_DATA | 268 | 1 | 1 | int8 -| boil2hystoff | hysteresis stage 2 off temperature | int8 (>=0<=20) | C | true | DEVICE_DATA | 268 | 1 | 1 | -| curveon | heatingcurve on | boolean | | true | DEVICE_DATA | 269 | 1 | 1 | +| boil2hystoff | hysteresis stage 2 off temperature | int8 (>=0<=20) | C | true | DEVICE_DATA | 269 | 1 | 1 | +| curveon | heatingcurve on | boolean | | true | DEVICE_DATA | 270 | 1 | 1 | uint8 -| curvebase | heatingcurve base | uint8 (>=20<=90) | C | true | DEVICE_DATA | 270 | 1 | 1 | +| curvebase | heatingcurve base | uint8 (>=20<=90) | C | true | DEVICE_DATA | 271 | 1 | 1 | uint8 -| curveend | heatingcurve end | uint8 (>=20<=90) | C | true | DEVICE_DATA | 271 | 1 | 1 | +| curveend | heatingcurve end | uint8 (>=20<=90) | C | true | DEVICE_DATA | 272 | 1 | 1 | uint8 -| summertemp | summer temperature | uint8 (>=0<=45) | C | true | DEVICE_DATA | 272 | 1 | 1 | -| nofrostmode | nofrost mode | boolean | | true | DEVICE_DATA | 273 | 1 | 1 | +| summertemp | summer temperature | uint8 (>=0<=45) | C | true | DEVICE_DATA | 273 | 1 | 1 | +| nofrostmode | nofrost mode | boolean | | true | DEVICE_DATA | 274 | 1 | 1 | uint8 -| nofrosttemp | nofrost temperature | uint8 (>=0<=10) | C | true | DEVICE_DATA | 274 | 1 | 1 | +| nofrosttemp | nofrost temperature | uint8 (>=0<=10) | C | true | DEVICE_DATA | 275 | 1 | 1 | | heatingactivated | heating activated | boolean | | true | DEVICE_DATA | 14 | 1 | 1 | uint8 | heatingtemp | heating temperature | uint8 (>=0<=90) | C | true | DEVICE_DATA | 15 | 1 | 1 | @@ -370,20 +371,21 @@ uint16 | emergencyops | emergency operation | boolean | | true | DEVICE_DATA | 78 | 1 | 1 | uint8 | emergencytemp | emergency temperature | uint8 (>=15<=70) | C | true | DEVICE_DATA | 79 | 1 | 1 | -| pc0flow | Flow PC0 | int16 | l/h | false | DEVICE_DATA | 80 | 1 | 1 | -| pc1flow | Flow PC1 | int16 | l/h | false | DEVICE_DATA | 81 | 1 | 1 | -| pc1on | PC1 | boolean | | false | DEVICE_DATA | 82 | 1 | 1 | -| pc1rate | PC1 rate | uint8 | % | false | DEVICE_DATA | 83 | 1 | 1 | +| pc0lpm | Flow PC0 | uint16 | l/min | false | DEVICE_DATA | 80 | 1 | 1/10 | +| pc0flow | Flow PC0 | uint16 | l/h | false | DEVICE_DATA | 81 | 1 | 1 | +| pc1flow | Flow PC1 | uint16 | l/h | false | DEVICE_DATA | 82 | 1 | 1 | +| pc1on | PC1 | boolean | | false | DEVICE_DATA | 83 | 1 | 1 | +| pc1rate | PC1 rate | uint8 | % | false | DEVICE_DATA | 84 | 1 | 1 | uint8 -| pumpkickhour | pump kick hour | uint8 (>=0<=23) | hours | true | DEVICE_DATA | 84 | 1 | 1 | -| pumpkickday | pump kick day | enum | | true | DEVICE_DATA | 85 | 1 | 1 | +| pumpkickhour | pump kick hour | uint8 (>=0<=23) | hours | true | DEVICE_DATA | 85 | 1 | 1 | +| pumpkickday | pump kick day | enum | | true | DEVICE_DATA | 86 | 1 | 1 | uint16 -| pumpkickdelay | pump kick delay | uint16 (>=0<=32767) | minutes | true | DEVICE_DATA | 86 | 1 | 1 | -| meterheat | meter heating | uint24 | kWh | false | DEVICE_DATA | 100 | 2 | 1/10 | +| pumpkickdelay | pump kick delay | uint16 (>=0<=32767) | minutes | true | DEVICE_DATA | 87 | 1 | 1 | +| meterheat | meter heating | uint24 | kWh | false | DEVICE_DATA | 101 | 2 | 1/10 | | dhw.meter | meter | uint24 | kWh | false | DHW | 2 | 2 | 1/10 | -| gasmeterheat | gas meter heating | uint24 | kWh | false | DEVICE_DATA | 275 | 2 | 1/10 | +| gasmeterheat | gas meter heating | uint24 | kWh | false | DEVICE_DATA | 276 | 2 | 1/10 | | dhw.gasmeter | gas meter | uint24 | kWh | false | DHW | 71 | 2 | 1/10 | -| nrgheat2 | energy heating 2 | uint24 | kWh | false | DEVICE_DATA | 277 | 2 | 1/10 | +| nrgheat2 | energy heating 2 | uint24 | kWh | false | DEVICE_DATA | 278 | 2 | 1/10 | | dhw.nrg2 | energy 2 | uint24 | kWh | false | DHW | 73 | 2 | 1/10 | | dhw.tapactivated | turn on/off | boolean | | true | DHW | 28 | 1 | 1 | | dhw.settemp | set temperature | uint8 | C | false | DHW | 29 | 1 | 1 | @@ -437,10 +439,10 @@ uint8 | dhw.starts | starts | uint24 | | false | DHW | 67 | 2 | 1 | | dhw.workm | active time | time | minutes | false | DHW | 69 | 2 | 1 | uint8 -| nompower | nominal Power | uint8 (>=0<=0) | kW | true | DEVICE_DATA | 279 | 1 | 1 | -| nrgtotal | total energy | uint24 | kWh | false | DEVICE_DATA | 88 | 2 | 1/100 | +| nompower | nominal Power | uint8 (>=0<=0) | kW | true | DEVICE_DATA | 280 | 1 | 1 | +| nrgtotal | total energy | uint24 | kWh | false | DEVICE_DATA | 89 | 2 | 1/100 | uint24 -| nrgheat | energy heating | uint24 (>=0<=10000000) | kWh | true | DEVICE_DATA | 90 | 2 | 1/100 | +| nrgheat | energy heating | uint24 (>=0<=10000000) | kWh | true | DEVICE_DATA | 91 | 2 | 1/100 | uint24 | dhw.nrg | energy | uint24 (>=0<=10000000) | kWh | true | DHW | 0 | 2 | 1/100 | @@ -463,39 +465,39 @@ uint8 | syspress | system pressure | uint8 | bar | false | DEVICE_DATA | 11 | 1 | 1/10 | | boiltemp | actual boiler temperature | uint16 | C | false | DEVICE_DATA | 12 | 1 | 1/10 | | headertemp | low loss header | uint16 | C | false | DEVICE_DATA | 13 | 1 | 1/10 | -| exhausttemp | exhaust temperature | uint16 | C | false | DEVICE_DATA | 253 | 1 | 1/10 | -| burngas | gas | boolean | | false | DEVICE_DATA | 254 | 1 | 1 | -| burngas2 | gas stage 2 | boolean | | false | DEVICE_DATA | 255 | 1 | 1 | -| flamecurr | flame current | uint16 | µA | false | DEVICE_DATA | 256 | 1 | 1/10 | -| fanwork | fan | boolean | | false | DEVICE_DATA | 257 | 1 | 1 | -| ignwork | ignition | boolean | | false | DEVICE_DATA | 258 | 1 | 1 | -| oilpreheat | oil preheating | boolean | | false | DEVICE_DATA | 259 | 1 | 1 | +| exhausttemp | exhaust temperature | uint16 | C | false | DEVICE_DATA | 254 | 1 | 1/10 | +| burngas | gas | boolean | | false | DEVICE_DATA | 255 | 1 | 1 | +| burngas2 | gas stage 2 | boolean | | false | DEVICE_DATA | 256 | 1 | 1 | +| flamecurr | flame current | uint16 | µA | false | DEVICE_DATA | 257 | 1 | 1/10 | +| fanwork | fan | boolean | | false | DEVICE_DATA | 258 | 1 | 1 | +| ignwork | ignition | boolean | | false | DEVICE_DATA | 259 | 1 | 1 | +| oilpreheat | oil preheating | boolean | | false | DEVICE_DATA | 260 | 1 | 1 | uint8 -| burnminpower | burner min power | uint8 (>=0<=0) | % | true | DEVICE_DATA | 260 | 1 | 1 | +| burnminpower | burner min power | uint8 (>=0<=0) | % | true | DEVICE_DATA | 261 | 1 | 1 | uint8 -| burnmaxpower | burner max power | uint8 (>=0<=254) | % | true | DEVICE_DATA | 261 | 1 | 1 | +| burnmaxpower | burner max power | uint8 (>=0<=254) | % | true | DEVICE_DATA | 262 | 1 | 1 | uint8 -| burnminperiod | burner min period | uint8 (>=0<=120) | minutes | true | DEVICE_DATA | 262 | 1 | 1 | -| absburnpow | burner current power (absolute) | uint8 | % | false | DEVICE_DATA | 263 | 1 | 1 | -| heatblock | Heatblock temperature | uint16 | C | false | DEVICE_DATA | 264 | 1 | 1/10 | +| burnminperiod | burner min period | uint8 (>=0<=120) | minutes | true | DEVICE_DATA | 263 | 1 | 1 | +| absburnpow | burner current power (absolute) | uint8 | % | false | DEVICE_DATA | 264 | 1 | 1 | +| heatblock | Heatblock temperature | uint16 | C | false | DEVICE_DATA | 265 | 1 | 1/10 | int8 -| boilhyston | hysteresis on temperature | int8 (>=-20<=0) | C | true | DEVICE_DATA | 265 | 1 | 1 | +| boilhyston | hysteresis on temperature | int8 (>=-20<=0) | C | true | DEVICE_DATA | 266 | 1 | 1 | int8 -| boilhystoff | hysteresis off temperature | int8 (>=0<=20) | C | true | DEVICE_DATA | 266 | 1 | 1 | +| boilhystoff | hysteresis off temperature | int8 (>=0<=20) | C | true | DEVICE_DATA | 267 | 1 | 1 | int8 -| boil2hyston | hysteresis stage 2 on temperature | int8 (>=-20<=0) | C | true | DEVICE_DATA | 267 | 1 | 1 | +| boil2hyston | hysteresis stage 2 on temperature | int8 (>=-20<=0) | C | true | DEVICE_DATA | 268 | 1 | 1 | int8 -| boil2hystoff | hysteresis stage 2 off temperature | int8 (>=0<=20) | C | true | DEVICE_DATA | 268 | 1 | 1 | -| curveon | heatingcurve on | boolean | | true | DEVICE_DATA | 269 | 1 | 1 | +| boil2hystoff | hysteresis stage 2 off temperature | int8 (>=0<=20) | C | true | DEVICE_DATA | 269 | 1 | 1 | +| curveon | heatingcurve on | boolean | | true | DEVICE_DATA | 270 | 1 | 1 | uint8 -| curvebase | heatingcurve base | uint8 (>=20<=90) | C | true | DEVICE_DATA | 270 | 1 | 1 | +| curvebase | heatingcurve base | uint8 (>=20<=90) | C | true | DEVICE_DATA | 271 | 1 | 1 | uint8 -| curveend | heatingcurve end | uint8 (>=20<=90) | C | true | DEVICE_DATA | 271 | 1 | 1 | +| curveend | heatingcurve end | uint8 (>=20<=90) | C | true | DEVICE_DATA | 272 | 1 | 1 | uint8 -| summertemp | summer temperature | uint8 (>=0<=45) | C | true | DEVICE_DATA | 272 | 1 | 1 | -| nofrostmode | nofrost mode | boolean | | true | DEVICE_DATA | 273 | 1 | 1 | +| summertemp | summer temperature | uint8 (>=0<=45) | C | true | DEVICE_DATA | 273 | 1 | 1 | +| nofrostmode | nofrost mode | boolean | | true | DEVICE_DATA | 274 | 1 | 1 | uint8 -| nofrosttemp | nofrost temperature | uint8 (>=0<=10) | C | true | DEVICE_DATA | 274 | 1 | 1 | +| nofrosttemp | nofrost temperature | uint8 (>=0<=10) | C | true | DEVICE_DATA | 275 | 1 | 1 | | heatingactivated | heating activated | boolean | | true | DEVICE_DATA | 14 | 1 | 1 | uint8 | heatingtemp | heating temperature | uint8 (>=0<=90) | C | true | DEVICE_DATA | 15 | 1 | 1 | @@ -530,20 +532,21 @@ uint16 | emergencyops | emergency operation | boolean | | true | DEVICE_DATA | 78 | 1 | 1 | uint8 | emergencytemp | emergency temperature | uint8 (>=15<=70) | C | true | DEVICE_DATA | 79 | 1 | 1 | -| pc0flow | Flow PC0 | int16 | l/h | false | DEVICE_DATA | 80 | 1 | 1 | -| pc1flow | Flow PC1 | int16 | l/h | false | DEVICE_DATA | 81 | 1 | 1 | -| pc1on | PC1 | boolean | | false | DEVICE_DATA | 82 | 1 | 1 | -| pc1rate | PC1 rate | uint8 | % | false | DEVICE_DATA | 83 | 1 | 1 | +| pc0lpm | Flow PC0 | uint16 | l/min | false | DEVICE_DATA | 80 | 1 | 1/10 | +| pc0flow | Flow PC0 | uint16 | l/h | false | DEVICE_DATA | 81 | 1 | 1 | +| pc1flow | Flow PC1 | uint16 | l/h | false | DEVICE_DATA | 82 | 1 | 1 | +| pc1on | PC1 | boolean | | false | DEVICE_DATA | 83 | 1 | 1 | +| pc1rate | PC1 rate | uint8 | % | false | DEVICE_DATA | 84 | 1 | 1 | uint8 -| pumpkickhour | pump kick hour | uint8 (>=0<=23) | hours | true | DEVICE_DATA | 84 | 1 | 1 | -| pumpkickday | pump kick day | enum | | true | DEVICE_DATA | 85 | 1 | 1 | +| pumpkickhour | pump kick hour | uint8 (>=0<=23) | hours | true | DEVICE_DATA | 85 | 1 | 1 | +| pumpkickday | pump kick day | enum | | true | DEVICE_DATA | 86 | 1 | 1 | uint16 -| pumpkickdelay | pump kick delay | uint16 (>=0<=32767) | minutes | true | DEVICE_DATA | 86 | 1 | 1 | -| meterheat | meter heating | uint24 | kWh | false | DEVICE_DATA | 100 | 2 | 1/10 | +| pumpkickdelay | pump kick delay | uint16 (>=0<=32767) | minutes | true | DEVICE_DATA | 87 | 1 | 1 | +| meterheat | meter heating | uint24 | kWh | false | DEVICE_DATA | 101 | 2 | 1/10 | | dhw.meter | meter | uint24 | kWh | false | DHW | 2 | 2 | 1/10 | -| gasmeterheat | gas meter heating | uint24 | kWh | false | DEVICE_DATA | 275 | 2 | 1/10 | +| gasmeterheat | gas meter heating | uint24 | kWh | false | DEVICE_DATA | 276 | 2 | 1/10 | | dhw.gasmeter | gas meter | uint24 | kWh | false | DHW | 71 | 2 | 1/10 | -| nrgheat2 | energy heating 2 | uint24 | kWh | false | DEVICE_DATA | 277 | 2 | 1/10 | +| nrgheat2 | energy heating 2 | uint24 | kWh | false | DEVICE_DATA | 278 | 2 | 1/10 | | dhw.nrg2 | energy 2 | uint24 | kWh | false | DHW | 73 | 2 | 1/10 | | dhw.tapactivated | turn on/off | boolean | | true | DHW | 28 | 1 | 1 | | dhw.settemp | set temperature | uint8 | C | false | DHW | 29 | 1 | 1 | @@ -597,10 +600,10 @@ uint8 | dhw.starts | starts | uint24 | | false | DHW | 67 | 2 | 1 | | dhw.workm | active time | time | minutes | false | DHW | 69 | 2 | 1 | uint8 -| nompower | nominal Power | uint8 (>=0<=0) | kW | true | DEVICE_DATA | 279 | 1 | 1 | -| nrgtotal | total energy | uint24 | kWh | false | DEVICE_DATA | 88 | 2 | 1/100 | +| nompower | nominal Power | uint8 (>=0<=0) | kW | true | DEVICE_DATA | 280 | 1 | 1 | +| nrgtotal | total energy | uint24 | kWh | false | DEVICE_DATA | 89 | 2 | 1/100 | uint24 -| nrgheat | energy heating | uint24 (>=0<=10000000) | kWh | true | DEVICE_DATA | 90 | 2 | 1/100 | +| nrgheat | energy heating | uint24 (>=0<=10000000) | kWh | true | DEVICE_DATA | 91 | 2 | 1/100 | uint24 | dhw.nrg | energy | uint24 (>=0<=10000000) | kWh | true | DHW | 0 | 2 | 1/100 | @@ -623,39 +626,39 @@ uint8 | syspress | system pressure | uint8 | bar | false | DEVICE_DATA | 11 | 1 | 1/10 | | boiltemp | actual boiler temperature | uint16 | C | false | DEVICE_DATA | 12 | 1 | 1/10 | | headertemp | low loss header | uint16 | C | false | DEVICE_DATA | 13 | 1 | 1/10 | -| exhausttemp | exhaust temperature | uint16 | C | false | DEVICE_DATA | 253 | 1 | 1/10 | -| burngas | gas | boolean | | false | DEVICE_DATA | 254 | 1 | 1 | -| burngas2 | gas stage 2 | boolean | | false | DEVICE_DATA | 255 | 1 | 1 | -| flamecurr | flame current | uint16 | µA | false | DEVICE_DATA | 256 | 1 | 1/10 | -| fanwork | fan | boolean | | false | DEVICE_DATA | 257 | 1 | 1 | -| ignwork | ignition | boolean | | false | DEVICE_DATA | 258 | 1 | 1 | -| oilpreheat | oil preheating | boolean | | false | DEVICE_DATA | 259 | 1 | 1 | +| exhausttemp | exhaust temperature | uint16 | C | false | DEVICE_DATA | 254 | 1 | 1/10 | +| burngas | gas | boolean | | false | DEVICE_DATA | 255 | 1 | 1 | +| burngas2 | gas stage 2 | boolean | | false | DEVICE_DATA | 256 | 1 | 1 | +| flamecurr | flame current | uint16 | µA | false | DEVICE_DATA | 257 | 1 | 1/10 | +| fanwork | fan | boolean | | false | DEVICE_DATA | 258 | 1 | 1 | +| ignwork | ignition | boolean | | false | DEVICE_DATA | 259 | 1 | 1 | +| oilpreheat | oil preheating | boolean | | false | DEVICE_DATA | 260 | 1 | 1 | uint8 -| burnminpower | burner min power | uint8 (>=0<=0) | % | true | DEVICE_DATA | 260 | 1 | 1 | +| burnminpower | burner min power | uint8 (>=0<=0) | % | true | DEVICE_DATA | 261 | 1 | 1 | uint8 -| burnmaxpower | burner max power | uint8 (>=0<=254) | % | true | DEVICE_DATA | 261 | 1 | 1 | +| burnmaxpower | burner max power | uint8 (>=0<=254) | % | true | DEVICE_DATA | 262 | 1 | 1 | uint8 -| burnminperiod | burner min period | uint8 (>=0<=120) | minutes | true | DEVICE_DATA | 262 | 1 | 1 | -| absburnpow | burner current power (absolute) | uint8 | % | false | DEVICE_DATA | 263 | 1 | 1 | -| heatblock | Heatblock temperature | uint16 | C | false | DEVICE_DATA | 264 | 1 | 1/10 | +| burnminperiod | burner min period | uint8 (>=0<=120) | minutes | true | DEVICE_DATA | 263 | 1 | 1 | +| absburnpow | burner current power (absolute) | uint8 | % | false | DEVICE_DATA | 264 | 1 | 1 | +| heatblock | Heatblock temperature | uint16 | C | false | DEVICE_DATA | 265 | 1 | 1/10 | int8 -| boilhyston | hysteresis on temperature | int8 (>=-20<=0) | C | true | DEVICE_DATA | 265 | 1 | 1 | +| boilhyston | hysteresis on temperature | int8 (>=-20<=0) | C | true | DEVICE_DATA | 266 | 1 | 1 | int8 -| boilhystoff | hysteresis off temperature | int8 (>=0<=20) | C | true | DEVICE_DATA | 266 | 1 | 1 | +| boilhystoff | hysteresis off temperature | int8 (>=0<=20) | C | true | DEVICE_DATA | 267 | 1 | 1 | int8 -| boil2hyston | hysteresis stage 2 on temperature | int8 (>=-20<=0) | C | true | DEVICE_DATA | 267 | 1 | 1 | +| boil2hyston | hysteresis stage 2 on temperature | int8 (>=-20<=0) | C | true | DEVICE_DATA | 268 | 1 | 1 | int8 -| boil2hystoff | hysteresis stage 2 off temperature | int8 (>=0<=20) | C | true | DEVICE_DATA | 268 | 1 | 1 | -| curveon | heatingcurve on | boolean | | true | DEVICE_DATA | 269 | 1 | 1 | +| boil2hystoff | hysteresis stage 2 off temperature | int8 (>=0<=20) | C | true | DEVICE_DATA | 269 | 1 | 1 | +| curveon | heatingcurve on | boolean | | true | DEVICE_DATA | 270 | 1 | 1 | uint8 -| curvebase | heatingcurve base | uint8 (>=20<=90) | C | true | DEVICE_DATA | 270 | 1 | 1 | +| curvebase | heatingcurve base | uint8 (>=20<=90) | C | true | DEVICE_DATA | 271 | 1 | 1 | uint8 -| curveend | heatingcurve end | uint8 (>=20<=90) | C | true | DEVICE_DATA | 271 | 1 | 1 | +| curveend | heatingcurve end | uint8 (>=20<=90) | C | true | DEVICE_DATA | 272 | 1 | 1 | uint8 -| summertemp | summer temperature | uint8 (>=0<=45) | C | true | DEVICE_DATA | 272 | 1 | 1 | -| nofrostmode | nofrost mode | boolean | | true | DEVICE_DATA | 273 | 1 | 1 | +| summertemp | summer temperature | uint8 (>=0<=45) | C | true | DEVICE_DATA | 273 | 1 | 1 | +| nofrostmode | nofrost mode | boolean | | true | DEVICE_DATA | 274 | 1 | 1 | uint8 -| nofrosttemp | nofrost temperature | uint8 (>=0<=10) | C | true | DEVICE_DATA | 274 | 1 | 1 | +| nofrosttemp | nofrost temperature | uint8 (>=0<=10) | C | true | DEVICE_DATA | 275 | 1 | 1 | | heatingactivated | heating activated | boolean | | true | DEVICE_DATA | 14 | 1 | 1 | uint8 | heatingtemp | heating temperature | uint8 (>=0<=90) | C | true | DEVICE_DATA | 15 | 1 | 1 | @@ -690,20 +693,21 @@ uint16 | emergencyops | emergency operation | boolean | | true | DEVICE_DATA | 78 | 1 | 1 | uint8 | emergencytemp | emergency temperature | uint8 (>=15<=70) | C | true | DEVICE_DATA | 79 | 1 | 1 | -| pc0flow | Flow PC0 | int16 | l/h | false | DEVICE_DATA | 80 | 1 | 1 | -| pc1flow | Flow PC1 | int16 | l/h | false | DEVICE_DATA | 81 | 1 | 1 | -| pc1on | PC1 | boolean | | false | DEVICE_DATA | 82 | 1 | 1 | -| pc1rate | PC1 rate | uint8 | % | false | DEVICE_DATA | 83 | 1 | 1 | +| pc0lpm | Flow PC0 | uint16 | l/min | false | DEVICE_DATA | 80 | 1 | 1/10 | +| pc0flow | Flow PC0 | uint16 | l/h | false | DEVICE_DATA | 81 | 1 | 1 | +| pc1flow | Flow PC1 | uint16 | l/h | false | DEVICE_DATA | 82 | 1 | 1 | +| pc1on | PC1 | boolean | | false | DEVICE_DATA | 83 | 1 | 1 | +| pc1rate | PC1 rate | uint8 | % | false | DEVICE_DATA | 84 | 1 | 1 | uint8 -| pumpkickhour | pump kick hour | uint8 (>=0<=23) | hours | true | DEVICE_DATA | 84 | 1 | 1 | -| pumpkickday | pump kick day | enum | | true | DEVICE_DATA | 85 | 1 | 1 | +| pumpkickhour | pump kick hour | uint8 (>=0<=23) | hours | true | DEVICE_DATA | 85 | 1 | 1 | +| pumpkickday | pump kick day | enum | | true | DEVICE_DATA | 86 | 1 | 1 | uint16 -| pumpkickdelay | pump kick delay | uint16 (>=0<=32767) | minutes | true | DEVICE_DATA | 86 | 1 | 1 | -| meterheat | meter heating | uint24 | kWh | false | DEVICE_DATA | 100 | 2 | 1/10 | +| pumpkickdelay | pump kick delay | uint16 (>=0<=32767) | minutes | true | DEVICE_DATA | 87 | 1 | 1 | +| meterheat | meter heating | uint24 | kWh | false | DEVICE_DATA | 101 | 2 | 1/10 | | dhw.meter | meter | uint24 | kWh | false | DHW | 2 | 2 | 1/10 | -| gasmeterheat | gas meter heating | uint24 | kWh | false | DEVICE_DATA | 275 | 2 | 1/10 | +| gasmeterheat | gas meter heating | uint24 | kWh | false | DEVICE_DATA | 276 | 2 | 1/10 | | dhw.gasmeter | gas meter | uint24 | kWh | false | DHW | 71 | 2 | 1/10 | -| nrgheat2 | energy heating 2 | uint24 | kWh | false | DEVICE_DATA | 277 | 2 | 1/10 | +| nrgheat2 | energy heating 2 | uint24 | kWh | false | DEVICE_DATA | 278 | 2 | 1/10 | | dhw.nrg2 | energy 2 | uint24 | kWh | false | DHW | 73 | 2 | 1/10 | | dhw.tapactivated | turn on/off | boolean | | true | DHW | 28 | 1 | 1 | | dhw.settemp | set temperature | uint8 | C | false | DHW | 29 | 1 | 1 | @@ -757,10 +761,10 @@ uint8 | dhw.starts | starts | uint24 | | false | DHW | 67 | 2 | 1 | | dhw.workm | active time | time | minutes | false | DHW | 69 | 2 | 1 | uint8 -| nompower | nominal Power | uint8 (>=0<=0) | kW | true | DEVICE_DATA | 279 | 1 | 1 | -| nrgtotal | total energy | uint24 | kWh | false | DEVICE_DATA | 88 | 2 | 1/100 | +| nompower | nominal Power | uint8 (>=0<=0) | kW | true | DEVICE_DATA | 280 | 1 | 1 | +| nrgtotal | total energy | uint24 | kWh | false | DEVICE_DATA | 89 | 2 | 1/100 | uint24 -| nrgheat | energy heating | uint24 (>=0<=10000000) | kWh | true | DEVICE_DATA | 90 | 2 | 1/100 | +| nrgheat | energy heating | uint24 (>=0<=10000000) | kWh | true | DEVICE_DATA | 91 | 2 | 1/100 | uint24 | dhw.nrg | energy | uint24 (>=0<=10000000) | kWh | true | DHW | 0 | 2 | 1/100 | @@ -783,39 +787,39 @@ uint8 | syspress | system pressure | uint8 | bar | false | DEVICE_DATA | 11 | 1 | 1/10 | | boiltemp | actual boiler temperature | uint16 | C | false | DEVICE_DATA | 12 | 1 | 1/10 | | headertemp | low loss header | uint16 | C | false | DEVICE_DATA | 13 | 1 | 1/10 | -| exhausttemp | exhaust temperature | uint16 | C | false | DEVICE_DATA | 253 | 1 | 1/10 | -| burngas | gas | boolean | | false | DEVICE_DATA | 254 | 1 | 1 | -| burngas2 | gas stage 2 | boolean | | false | DEVICE_DATA | 255 | 1 | 1 | -| flamecurr | flame current | uint16 | µA | false | DEVICE_DATA | 256 | 1 | 1/10 | -| fanwork | fan | boolean | | false | DEVICE_DATA | 257 | 1 | 1 | -| ignwork | ignition | boolean | | false | DEVICE_DATA | 258 | 1 | 1 | -| oilpreheat | oil preheating | boolean | | false | DEVICE_DATA | 259 | 1 | 1 | +| exhausttemp | exhaust temperature | uint16 | C | false | DEVICE_DATA | 254 | 1 | 1/10 | +| burngas | gas | boolean | | false | DEVICE_DATA | 255 | 1 | 1 | +| burngas2 | gas stage 2 | boolean | | false | DEVICE_DATA | 256 | 1 | 1 | +| flamecurr | flame current | uint16 | µA | false | DEVICE_DATA | 257 | 1 | 1/10 | +| fanwork | fan | boolean | | false | DEVICE_DATA | 258 | 1 | 1 | +| ignwork | ignition | boolean | | false | DEVICE_DATA | 259 | 1 | 1 | +| oilpreheat | oil preheating | boolean | | false | DEVICE_DATA | 260 | 1 | 1 | uint8 -| burnminpower | burner min power | uint8 (>=0<=0) | % | true | DEVICE_DATA | 260 | 1 | 1 | +| burnminpower | burner min power | uint8 (>=0<=0) | % | true | DEVICE_DATA | 261 | 1 | 1 | uint8 -| burnmaxpower | burner max power | uint8 (>=0<=254) | % | true | DEVICE_DATA | 261 | 1 | 1 | +| burnmaxpower | burner max power | uint8 (>=0<=254) | % | true | DEVICE_DATA | 262 | 1 | 1 | uint8 -| burnminperiod | burner min period | uint8 (>=0<=120) | minutes | true | DEVICE_DATA | 262 | 1 | 1 | -| absburnpow | burner current power (absolute) | uint8 | % | false | DEVICE_DATA | 263 | 1 | 1 | -| heatblock | Heatblock temperature | uint16 | C | false | DEVICE_DATA | 264 | 1 | 1/10 | +| burnminperiod | burner min period | uint8 (>=0<=120) | minutes | true | DEVICE_DATA | 263 | 1 | 1 | +| absburnpow | burner current power (absolute) | uint8 | % | false | DEVICE_DATA | 264 | 1 | 1 | +| heatblock | Heatblock temperature | uint16 | C | false | DEVICE_DATA | 265 | 1 | 1/10 | int8 -| boilhyston | hysteresis on temperature | int8 (>=-20<=0) | C | true | DEVICE_DATA | 265 | 1 | 1 | +| boilhyston | hysteresis on temperature | int8 (>=-20<=0) | C | true | DEVICE_DATA | 266 | 1 | 1 | int8 -| boilhystoff | hysteresis off temperature | int8 (>=0<=20) | C | true | DEVICE_DATA | 266 | 1 | 1 | +| boilhystoff | hysteresis off temperature | int8 (>=0<=20) | C | true | DEVICE_DATA | 267 | 1 | 1 | int8 -| boil2hyston | hysteresis stage 2 on temperature | int8 (>=-20<=0) | C | true | DEVICE_DATA | 267 | 1 | 1 | +| boil2hyston | hysteresis stage 2 on temperature | int8 (>=-20<=0) | C | true | DEVICE_DATA | 268 | 1 | 1 | int8 -| boil2hystoff | hysteresis stage 2 off temperature | int8 (>=0<=20) | C | true | DEVICE_DATA | 268 | 1 | 1 | -| curveon | heatingcurve on | boolean | | true | DEVICE_DATA | 269 | 1 | 1 | +| boil2hystoff | hysteresis stage 2 off temperature | int8 (>=0<=20) | C | true | DEVICE_DATA | 269 | 1 | 1 | +| curveon | heatingcurve on | boolean | | true | DEVICE_DATA | 270 | 1 | 1 | uint8 -| curvebase | heatingcurve base | uint8 (>=20<=90) | C | true | DEVICE_DATA | 270 | 1 | 1 | +| curvebase | heatingcurve base | uint8 (>=20<=90) | C | true | DEVICE_DATA | 271 | 1 | 1 | uint8 -| curveend | heatingcurve end | uint8 (>=20<=90) | C | true | DEVICE_DATA | 271 | 1 | 1 | +| curveend | heatingcurve end | uint8 (>=20<=90) | C | true | DEVICE_DATA | 272 | 1 | 1 | uint8 -| summertemp | summer temperature | uint8 (>=0<=45) | C | true | DEVICE_DATA | 272 | 1 | 1 | -| nofrostmode | nofrost mode | boolean | | true | DEVICE_DATA | 273 | 1 | 1 | +| summertemp | summer temperature | uint8 (>=0<=45) | C | true | DEVICE_DATA | 273 | 1 | 1 | +| nofrostmode | nofrost mode | boolean | | true | DEVICE_DATA | 274 | 1 | 1 | uint8 -| nofrosttemp | nofrost temperature | uint8 (>=0<=10) | C | true | DEVICE_DATA | 274 | 1 | 1 | +| nofrosttemp | nofrost temperature | uint8 (>=0<=10) | C | true | DEVICE_DATA | 275 | 1 | 1 | | heatingactivated | heating activated | boolean | | true | DEVICE_DATA | 14 | 1 | 1 | uint8 | heatingtemp | heating temperature | uint8 (>=0<=90) | C | true | DEVICE_DATA | 15 | 1 | 1 | @@ -850,20 +854,21 @@ uint16 | emergencyops | emergency operation | boolean | | true | DEVICE_DATA | 78 | 1 | 1 | uint8 | emergencytemp | emergency temperature | uint8 (>=15<=70) | C | true | DEVICE_DATA | 79 | 1 | 1 | -| pc0flow | Flow PC0 | int16 | l/h | false | DEVICE_DATA | 80 | 1 | 1 | -| pc1flow | Flow PC1 | int16 | l/h | false | DEVICE_DATA | 81 | 1 | 1 | -| pc1on | PC1 | boolean | | false | DEVICE_DATA | 82 | 1 | 1 | -| pc1rate | PC1 rate | uint8 | % | false | DEVICE_DATA | 83 | 1 | 1 | +| pc0lpm | Flow PC0 | uint16 | l/min | false | DEVICE_DATA | 80 | 1 | 1/10 | +| pc0flow | Flow PC0 | uint16 | l/h | false | DEVICE_DATA | 81 | 1 | 1 | +| pc1flow | Flow PC1 | uint16 | l/h | false | DEVICE_DATA | 82 | 1 | 1 | +| pc1on | PC1 | boolean | | false | DEVICE_DATA | 83 | 1 | 1 | +| pc1rate | PC1 rate | uint8 | % | false | DEVICE_DATA | 84 | 1 | 1 | uint8 -| pumpkickhour | pump kick hour | uint8 (>=0<=23) | hours | true | DEVICE_DATA | 84 | 1 | 1 | -| pumpkickday | pump kick day | enum | | true | DEVICE_DATA | 85 | 1 | 1 | +| pumpkickhour | pump kick hour | uint8 (>=0<=23) | hours | true | DEVICE_DATA | 85 | 1 | 1 | +| pumpkickday | pump kick day | enum | | true | DEVICE_DATA | 86 | 1 | 1 | uint16 -| pumpkickdelay | pump kick delay | uint16 (>=0<=32767) | minutes | true | DEVICE_DATA | 86 | 1 | 1 | -| meterheat | meter heating | uint24 | kWh | false | DEVICE_DATA | 100 | 2 | 1/10 | +| pumpkickdelay | pump kick delay | uint16 (>=0<=32767) | minutes | true | DEVICE_DATA | 87 | 1 | 1 | +| meterheat | meter heating | uint24 | kWh | false | DEVICE_DATA | 101 | 2 | 1/10 | | dhw.meter | meter | uint24 | kWh | false | DHW | 2 | 2 | 1/10 | -| gasmeterheat | gas meter heating | uint24 | kWh | false | DEVICE_DATA | 275 | 2 | 1/10 | +| gasmeterheat | gas meter heating | uint24 | kWh | false | DEVICE_DATA | 276 | 2 | 1/10 | | dhw.gasmeter | gas meter | uint24 | kWh | false | DHW | 71 | 2 | 1/10 | -| nrgheat2 | energy heating 2 | uint24 | kWh | false | DEVICE_DATA | 277 | 2 | 1/10 | +| nrgheat2 | energy heating 2 | uint24 | kWh | false | DEVICE_DATA | 278 | 2 | 1/10 | | dhw.nrg2 | energy 2 | uint24 | kWh | false | DHW | 73 | 2 | 1/10 | | dhw.tapactivated | turn on/off | boolean | | true | DHW | 28 | 1 | 1 | | dhw.settemp | set temperature | uint8 | C | false | DHW | 29 | 1 | 1 | @@ -917,10 +922,10 @@ uint8 | dhw.starts | starts | uint24 | | false | DHW | 67 | 2 | 1 | | dhw.workm | active time | time | minutes | false | DHW | 69 | 2 | 1 | uint8 -| nompower | nominal Power | uint8 (>=0<=0) | kW | true | DEVICE_DATA | 279 | 1 | 1 | -| nrgtotal | total energy | uint24 | kWh | false | DEVICE_DATA | 88 | 2 | 1/100 | +| nompower | nominal Power | uint8 (>=0<=0) | kW | true | DEVICE_DATA | 280 | 1 | 1 | +| nrgtotal | total energy | uint24 | kWh | false | DEVICE_DATA | 89 | 2 | 1/100 | uint24 -| nrgheat | energy heating | uint24 (>=0<=10000000) | kWh | true | DEVICE_DATA | 90 | 2 | 1/100 | +| nrgheat | energy heating | uint24 (>=0<=10000000) | kWh | true | DEVICE_DATA | 91 | 2 | 1/100 | uint24 | dhw.nrg | energy | uint24 (>=0<=10000000) | kWh | true | DHW | 0 | 2 | 1/100 | @@ -943,39 +948,39 @@ uint8 | syspress | system pressure | uint8 | bar | false | DEVICE_DATA | 11 | 1 | 1/10 | | boiltemp | actual boiler temperature | uint16 | C | false | DEVICE_DATA | 12 | 1 | 1/10 | | headertemp | low loss header | uint16 | C | false | DEVICE_DATA | 13 | 1 | 1/10 | -| exhausttemp | exhaust temperature | uint16 | C | false | DEVICE_DATA | 253 | 1 | 1/10 | -| burngas | gas | boolean | | false | DEVICE_DATA | 254 | 1 | 1 | -| burngas2 | gas stage 2 | boolean | | false | DEVICE_DATA | 255 | 1 | 1 | -| flamecurr | flame current | uint16 | µA | false | DEVICE_DATA | 256 | 1 | 1/10 | -| fanwork | fan | boolean | | false | DEVICE_DATA | 257 | 1 | 1 | -| ignwork | ignition | boolean | | false | DEVICE_DATA | 258 | 1 | 1 | -| oilpreheat | oil preheating | boolean | | false | DEVICE_DATA | 259 | 1 | 1 | +| exhausttemp | exhaust temperature | uint16 | C | false | DEVICE_DATA | 254 | 1 | 1/10 | +| burngas | gas | boolean | | false | DEVICE_DATA | 255 | 1 | 1 | +| burngas2 | gas stage 2 | boolean | | false | DEVICE_DATA | 256 | 1 | 1 | +| flamecurr | flame current | uint16 | µA | false | DEVICE_DATA | 257 | 1 | 1/10 | +| fanwork | fan | boolean | | false | DEVICE_DATA | 258 | 1 | 1 | +| ignwork | ignition | boolean | | false | DEVICE_DATA | 259 | 1 | 1 | +| oilpreheat | oil preheating | boolean | | false | DEVICE_DATA | 260 | 1 | 1 | uint8 -| burnminpower | burner min power | uint8 (>=0<=0) | % | true | DEVICE_DATA | 260 | 1 | 1 | +| burnminpower | burner min power | uint8 (>=0<=0) | % | true | DEVICE_DATA | 261 | 1 | 1 | uint8 -| burnmaxpower | burner max power | uint8 (>=0<=254) | % | true | DEVICE_DATA | 261 | 1 | 1 | +| burnmaxpower | burner max power | uint8 (>=0<=254) | % | true | DEVICE_DATA | 262 | 1 | 1 | uint8 -| burnminperiod | burner min period | uint8 (>=0<=120) | minutes | true | DEVICE_DATA | 262 | 1 | 1 | -| absburnpow | burner current power (absolute) | uint8 | % | false | DEVICE_DATA | 263 | 1 | 1 | -| heatblock | Heatblock temperature | uint16 | C | false | DEVICE_DATA | 264 | 1 | 1/10 | +| burnminperiod | burner min period | uint8 (>=0<=120) | minutes | true | DEVICE_DATA | 263 | 1 | 1 | +| absburnpow | burner current power (absolute) | uint8 | % | false | DEVICE_DATA | 264 | 1 | 1 | +| heatblock | Heatblock temperature | uint16 | C | false | DEVICE_DATA | 265 | 1 | 1/10 | int8 -| boilhyston | hysteresis on temperature | int8 (>=-20<=0) | C | true | DEVICE_DATA | 265 | 1 | 1 | +| boilhyston | hysteresis on temperature | int8 (>=-20<=0) | C | true | DEVICE_DATA | 266 | 1 | 1 | int8 -| boilhystoff | hysteresis off temperature | int8 (>=0<=20) | C | true | DEVICE_DATA | 266 | 1 | 1 | +| boilhystoff | hysteresis off temperature | int8 (>=0<=20) | C | true | DEVICE_DATA | 267 | 1 | 1 | int8 -| boil2hyston | hysteresis stage 2 on temperature | int8 (>=-20<=0) | C | true | DEVICE_DATA | 267 | 1 | 1 | +| boil2hyston | hysteresis stage 2 on temperature | int8 (>=-20<=0) | C | true | DEVICE_DATA | 268 | 1 | 1 | int8 -| boil2hystoff | hysteresis stage 2 off temperature | int8 (>=0<=20) | C | true | DEVICE_DATA | 268 | 1 | 1 | -| curveon | heatingcurve on | boolean | | true | DEVICE_DATA | 269 | 1 | 1 | +| boil2hystoff | hysteresis stage 2 off temperature | int8 (>=0<=20) | C | true | DEVICE_DATA | 269 | 1 | 1 | +| curveon | heatingcurve on | boolean | | true | DEVICE_DATA | 270 | 1 | 1 | uint8 -| curvebase | heatingcurve base | uint8 (>=20<=90) | C | true | DEVICE_DATA | 270 | 1 | 1 | +| curvebase | heatingcurve base | uint8 (>=20<=90) | C | true | DEVICE_DATA | 271 | 1 | 1 | uint8 -| curveend | heatingcurve end | uint8 (>=20<=90) | C | true | DEVICE_DATA | 271 | 1 | 1 | +| curveend | heatingcurve end | uint8 (>=20<=90) | C | true | DEVICE_DATA | 272 | 1 | 1 | uint8 -| summertemp | summer temperature | uint8 (>=0<=45) | C | true | DEVICE_DATA | 272 | 1 | 1 | -| nofrostmode | nofrost mode | boolean | | true | DEVICE_DATA | 273 | 1 | 1 | +| summertemp | summer temperature | uint8 (>=0<=45) | C | true | DEVICE_DATA | 273 | 1 | 1 | +| nofrostmode | nofrost mode | boolean | | true | DEVICE_DATA | 274 | 1 | 1 | uint8 -| nofrosttemp | nofrost temperature | uint8 (>=0<=10) | C | true | DEVICE_DATA | 274 | 1 | 1 | +| nofrosttemp | nofrost temperature | uint8 (>=0<=10) | C | true | DEVICE_DATA | 275 | 1 | 1 | | heatingactivated | heating activated | boolean | | true | DEVICE_DATA | 14 | 1 | 1 | uint8 | heatingtemp | heating temperature | uint8 (>=0<=90) | C | true | DEVICE_DATA | 15 | 1 | 1 | @@ -1010,20 +1015,21 @@ uint16 | emergencyops | emergency operation | boolean | | true | DEVICE_DATA | 78 | 1 | 1 | uint8 | emergencytemp | emergency temperature | uint8 (>=15<=70) | C | true | DEVICE_DATA | 79 | 1 | 1 | -| pc0flow | Flow PC0 | int16 | l/h | false | DEVICE_DATA | 80 | 1 | 1 | -| pc1flow | Flow PC1 | int16 | l/h | false | DEVICE_DATA | 81 | 1 | 1 | -| pc1on | PC1 | boolean | | false | DEVICE_DATA | 82 | 1 | 1 | -| pc1rate | PC1 rate | uint8 | % | false | DEVICE_DATA | 83 | 1 | 1 | +| pc0lpm | Flow PC0 | uint16 | l/min | false | DEVICE_DATA | 80 | 1 | 1/10 | +| pc0flow | Flow PC0 | uint16 | l/h | false | DEVICE_DATA | 81 | 1 | 1 | +| pc1flow | Flow PC1 | uint16 | l/h | false | DEVICE_DATA | 82 | 1 | 1 | +| pc1on | PC1 | boolean | | false | DEVICE_DATA | 83 | 1 | 1 | +| pc1rate | PC1 rate | uint8 | % | false | DEVICE_DATA | 84 | 1 | 1 | uint8 -| pumpkickhour | pump kick hour | uint8 (>=0<=23) | hours | true | DEVICE_DATA | 84 | 1 | 1 | -| pumpkickday | pump kick day | enum | | true | DEVICE_DATA | 85 | 1 | 1 | +| pumpkickhour | pump kick hour | uint8 (>=0<=23) | hours | true | DEVICE_DATA | 85 | 1 | 1 | +| pumpkickday | pump kick day | enum | | true | DEVICE_DATA | 86 | 1 | 1 | uint16 -| pumpkickdelay | pump kick delay | uint16 (>=0<=32767) | minutes | true | DEVICE_DATA | 86 | 1 | 1 | -| meterheat | meter heating | uint24 | kWh | false | DEVICE_DATA | 100 | 2 | 1/10 | +| pumpkickdelay | pump kick delay | uint16 (>=0<=32767) | minutes | true | DEVICE_DATA | 87 | 1 | 1 | +| meterheat | meter heating | uint24 | kWh | false | DEVICE_DATA | 101 | 2 | 1/10 | | dhw.meter | meter | uint24 | kWh | false | DHW | 2 | 2 | 1/10 | -| gasmeterheat | gas meter heating | uint24 | kWh | false | DEVICE_DATA | 275 | 2 | 1/10 | +| gasmeterheat | gas meter heating | uint24 | kWh | false | DEVICE_DATA | 276 | 2 | 1/10 | | dhw.gasmeter | gas meter | uint24 | kWh | false | DHW | 71 | 2 | 1/10 | -| nrgheat2 | energy heating 2 | uint24 | kWh | false | DEVICE_DATA | 277 | 2 | 1/10 | +| nrgheat2 | energy heating 2 | uint24 | kWh | false | DEVICE_DATA | 278 | 2 | 1/10 | | dhw.nrg2 | energy 2 | uint24 | kWh | false | DHW | 73 | 2 | 1/10 | | dhw.tapactivated | turn on/off | boolean | | true | DHW | 28 | 1 | 1 | | dhw.settemp | set temperature | uint8 | C | false | DHW | 29 | 1 | 1 | @@ -1077,10 +1083,10 @@ uint8 | dhw.starts | starts | uint24 | | false | DHW | 67 | 2 | 1 | | dhw.workm | active time | time | minutes | false | DHW | 69 | 2 | 1 | uint8 -| nompower | nominal Power | uint8 (>=0<=0) | kW | true | DEVICE_DATA | 279 | 1 | 1 | -| nrgtotal | total energy | uint24 | kWh | false | DEVICE_DATA | 88 | 2 | 1/100 | +| nompower | nominal Power | uint8 (>=0<=0) | kW | true | DEVICE_DATA | 280 | 1 | 1 | +| nrgtotal | total energy | uint24 | kWh | false | DEVICE_DATA | 89 | 2 | 1/100 | uint24 -| nrgheat | energy heating | uint24 (>=0<=10000000) | kWh | true | DEVICE_DATA | 90 | 2 | 1/100 | +| nrgheat | energy heating | uint24 (>=0<=10000000) | kWh | true | DEVICE_DATA | 91 | 2 | 1/100 | uint24 | dhw.nrg | energy | uint24 (>=0<=10000000) | kWh | true | DHW | 0 | 2 | 1/100 | @@ -1103,39 +1109,39 @@ uint8 | syspress | system pressure | uint8 | bar | false | DEVICE_DATA | 11 | 1 | 1/10 | | boiltemp | actual boiler temperature | uint16 | C | false | DEVICE_DATA | 12 | 1 | 1/10 | | headertemp | low loss header | uint16 | C | false | DEVICE_DATA | 13 | 1 | 1/10 | -| exhausttemp | exhaust temperature | uint16 | C | false | DEVICE_DATA | 253 | 1 | 1/10 | -| burngas | gas | boolean | | false | DEVICE_DATA | 254 | 1 | 1 | -| burngas2 | gas stage 2 | boolean | | false | DEVICE_DATA | 255 | 1 | 1 | -| flamecurr | flame current | uint16 | µA | false | DEVICE_DATA | 256 | 1 | 1/10 | -| fanwork | fan | boolean | | false | DEVICE_DATA | 257 | 1 | 1 | -| ignwork | ignition | boolean | | false | DEVICE_DATA | 258 | 1 | 1 | -| oilpreheat | oil preheating | boolean | | false | DEVICE_DATA | 259 | 1 | 1 | +| exhausttemp | exhaust temperature | uint16 | C | false | DEVICE_DATA | 254 | 1 | 1/10 | +| burngas | gas | boolean | | false | DEVICE_DATA | 255 | 1 | 1 | +| burngas2 | gas stage 2 | boolean | | false | DEVICE_DATA | 256 | 1 | 1 | +| flamecurr | flame current | uint16 | µA | false | DEVICE_DATA | 257 | 1 | 1/10 | +| fanwork | fan | boolean | | false | DEVICE_DATA | 258 | 1 | 1 | +| ignwork | ignition | boolean | | false | DEVICE_DATA | 259 | 1 | 1 | +| oilpreheat | oil preheating | boolean | | false | DEVICE_DATA | 260 | 1 | 1 | uint8 -| burnminpower | burner min power | uint8 (>=0<=0) | % | true | DEVICE_DATA | 260 | 1 | 1 | +| burnminpower | burner min power | uint8 (>=0<=0) | % | true | DEVICE_DATA | 261 | 1 | 1 | uint8 -| burnmaxpower | burner max power | uint8 (>=0<=254) | % | true | DEVICE_DATA | 261 | 1 | 1 | +| burnmaxpower | burner max power | uint8 (>=0<=254) | % | true | DEVICE_DATA | 262 | 1 | 1 | uint8 -| burnminperiod | burner min period | uint8 (>=0<=120) | minutes | true | DEVICE_DATA | 262 | 1 | 1 | -| absburnpow | burner current power (absolute) | uint8 | % | false | DEVICE_DATA | 263 | 1 | 1 | -| heatblock | Heatblock temperature | uint16 | C | false | DEVICE_DATA | 264 | 1 | 1/10 | +| burnminperiod | burner min period | uint8 (>=0<=120) | minutes | true | DEVICE_DATA | 263 | 1 | 1 | +| absburnpow | burner current power (absolute) | uint8 | % | false | DEVICE_DATA | 264 | 1 | 1 | +| heatblock | Heatblock temperature | uint16 | C | false | DEVICE_DATA | 265 | 1 | 1/10 | int8 -| boilhyston | hysteresis on temperature | int8 (>=-20<=0) | C | true | DEVICE_DATA | 265 | 1 | 1 | +| boilhyston | hysteresis on temperature | int8 (>=-20<=0) | C | true | DEVICE_DATA | 266 | 1 | 1 | int8 -| boilhystoff | hysteresis off temperature | int8 (>=0<=20) | C | true | DEVICE_DATA | 266 | 1 | 1 | +| boilhystoff | hysteresis off temperature | int8 (>=0<=20) | C | true | DEVICE_DATA | 267 | 1 | 1 | int8 -| boil2hyston | hysteresis stage 2 on temperature | int8 (>=-20<=0) | C | true | DEVICE_DATA | 267 | 1 | 1 | +| boil2hyston | hysteresis stage 2 on temperature | int8 (>=-20<=0) | C | true | DEVICE_DATA | 268 | 1 | 1 | int8 -| boil2hystoff | hysteresis stage 2 off temperature | int8 (>=0<=20) | C | true | DEVICE_DATA | 268 | 1 | 1 | -| curveon | heatingcurve on | boolean | | true | DEVICE_DATA | 269 | 1 | 1 | +| boil2hystoff | hysteresis stage 2 off temperature | int8 (>=0<=20) | C | true | DEVICE_DATA | 269 | 1 | 1 | +| curveon | heatingcurve on | boolean | | true | DEVICE_DATA | 270 | 1 | 1 | uint8 -| curvebase | heatingcurve base | uint8 (>=20<=90) | C | true | DEVICE_DATA | 270 | 1 | 1 | +| curvebase | heatingcurve base | uint8 (>=20<=90) | C | true | DEVICE_DATA | 271 | 1 | 1 | uint8 -| curveend | heatingcurve end | uint8 (>=20<=90) | C | true | DEVICE_DATA | 271 | 1 | 1 | +| curveend | heatingcurve end | uint8 (>=20<=90) | C | true | DEVICE_DATA | 272 | 1 | 1 | uint8 -| summertemp | summer temperature | uint8 (>=0<=45) | C | true | DEVICE_DATA | 272 | 1 | 1 | -| nofrostmode | nofrost mode | boolean | | true | DEVICE_DATA | 273 | 1 | 1 | +| summertemp | summer temperature | uint8 (>=0<=45) | C | true | DEVICE_DATA | 273 | 1 | 1 | +| nofrostmode | nofrost mode | boolean | | true | DEVICE_DATA | 274 | 1 | 1 | uint8 -| nofrosttemp | nofrost temperature | uint8 (>=0<=10) | C | true | DEVICE_DATA | 274 | 1 | 1 | +| nofrosttemp | nofrost temperature | uint8 (>=0<=10) | C | true | DEVICE_DATA | 275 | 1 | 1 | | heatingactivated | heating activated | boolean | | true | DEVICE_DATA | 14 | 1 | 1 | uint8 | heatingtemp | heating temperature | uint8 (>=0<=90) | C | true | DEVICE_DATA | 15 | 1 | 1 | @@ -1170,20 +1176,21 @@ uint16 | emergencyops | emergency operation | boolean | | true | DEVICE_DATA | 78 | 1 | 1 | uint8 | emergencytemp | emergency temperature | uint8 (>=15<=70) | C | true | DEVICE_DATA | 79 | 1 | 1 | -| pc0flow | Flow PC0 | int16 | l/h | false | DEVICE_DATA | 80 | 1 | 1 | -| pc1flow | Flow PC1 | int16 | l/h | false | DEVICE_DATA | 81 | 1 | 1 | -| pc1on | PC1 | boolean | | false | DEVICE_DATA | 82 | 1 | 1 | -| pc1rate | PC1 rate | uint8 | % | false | DEVICE_DATA | 83 | 1 | 1 | +| pc0lpm | Flow PC0 | uint16 | l/min | false | DEVICE_DATA | 80 | 1 | 1/10 | +| pc0flow | Flow PC0 | uint16 | l/h | false | DEVICE_DATA | 81 | 1 | 1 | +| pc1flow | Flow PC1 | uint16 | l/h | false | DEVICE_DATA | 82 | 1 | 1 | +| pc1on | PC1 | boolean | | false | DEVICE_DATA | 83 | 1 | 1 | +| pc1rate | PC1 rate | uint8 | % | false | DEVICE_DATA | 84 | 1 | 1 | uint8 -| pumpkickhour | pump kick hour | uint8 (>=0<=23) | hours | true | DEVICE_DATA | 84 | 1 | 1 | -| pumpkickday | pump kick day | enum | | true | DEVICE_DATA | 85 | 1 | 1 | +| pumpkickhour | pump kick hour | uint8 (>=0<=23) | hours | true | DEVICE_DATA | 85 | 1 | 1 | +| pumpkickday | pump kick day | enum | | true | DEVICE_DATA | 86 | 1 | 1 | uint16 -| pumpkickdelay | pump kick delay | uint16 (>=0<=32767) | minutes | true | DEVICE_DATA | 86 | 1 | 1 | -| meterheat | meter heating | uint24 | kWh | false | DEVICE_DATA | 100 | 2 | 1/10 | +| pumpkickdelay | pump kick delay | uint16 (>=0<=32767) | minutes | true | DEVICE_DATA | 87 | 1 | 1 | +| meterheat | meter heating | uint24 | kWh | false | DEVICE_DATA | 101 | 2 | 1/10 | | dhw.meter | meter | uint24 | kWh | false | DHW | 2 | 2 | 1/10 | -| gasmeterheat | gas meter heating | uint24 | kWh | false | DEVICE_DATA | 275 | 2 | 1/10 | +| gasmeterheat | gas meter heating | uint24 | kWh | false | DEVICE_DATA | 276 | 2 | 1/10 | | dhw.gasmeter | gas meter | uint24 | kWh | false | DHW | 71 | 2 | 1/10 | -| nrgheat2 | energy heating 2 | uint24 | kWh | false | DEVICE_DATA | 277 | 2 | 1/10 | +| nrgheat2 | energy heating 2 | uint24 | kWh | false | DEVICE_DATA | 278 | 2 | 1/10 | | dhw.nrg2 | energy 2 | uint24 | kWh | false | DHW | 73 | 2 | 1/10 | | dhw.tapactivated | turn on/off | boolean | | true | DHW | 28 | 1 | 1 | | dhw.settemp | set temperature | uint8 | C | false | DHW | 29 | 1 | 1 | @@ -1237,10 +1244,10 @@ uint8 | dhw.starts | starts | uint24 | | false | DHW | 67 | 2 | 1 | | dhw.workm | active time | time | minutes | false | DHW | 69 | 2 | 1 | uint8 -| nompower | nominal Power | uint8 (>=0<=0) | kW | true | DEVICE_DATA | 279 | 1 | 1 | -| nrgtotal | total energy | uint24 | kWh | false | DEVICE_DATA | 88 | 2 | 1/100 | +| nompower | nominal Power | uint8 (>=0<=0) | kW | true | DEVICE_DATA | 280 | 1 | 1 | +| nrgtotal | total energy | uint24 | kWh | false | DEVICE_DATA | 89 | 2 | 1/100 | uint24 -| nrgheat | energy heating | uint24 (>=0<=10000000) | kWh | true | DEVICE_DATA | 90 | 2 | 1/100 | +| nrgheat | energy heating | uint24 (>=0<=10000000) | kWh | true | DEVICE_DATA | 91 | 2 | 1/100 | uint24 | dhw.nrg | energy | uint24 (>=0<=10000000) | kWh | true | DHW | 0 | 2 | 1/100 | @@ -1263,39 +1270,39 @@ uint8 | syspress | system pressure | uint8 | bar | false | DEVICE_DATA | 11 | 1 | 1/10 | | boiltemp | actual boiler temperature | uint16 | C | false | DEVICE_DATA | 12 | 1 | 1/10 | | headertemp | low loss header | uint16 | C | false | DEVICE_DATA | 13 | 1 | 1/10 | -| exhausttemp | exhaust temperature | uint16 | C | false | DEVICE_DATA | 253 | 1 | 1/10 | -| burngas | gas | boolean | | false | DEVICE_DATA | 254 | 1 | 1 | -| burngas2 | gas stage 2 | boolean | | false | DEVICE_DATA | 255 | 1 | 1 | -| flamecurr | flame current | uint16 | µA | false | DEVICE_DATA | 256 | 1 | 1/10 | -| fanwork | fan | boolean | | false | DEVICE_DATA | 257 | 1 | 1 | -| ignwork | ignition | boolean | | false | DEVICE_DATA | 258 | 1 | 1 | -| oilpreheat | oil preheating | boolean | | false | DEVICE_DATA | 259 | 1 | 1 | +| exhausttemp | exhaust temperature | uint16 | C | false | DEVICE_DATA | 254 | 1 | 1/10 | +| burngas | gas | boolean | | false | DEVICE_DATA | 255 | 1 | 1 | +| burngas2 | gas stage 2 | boolean | | false | DEVICE_DATA | 256 | 1 | 1 | +| flamecurr | flame current | uint16 | µA | false | DEVICE_DATA | 257 | 1 | 1/10 | +| fanwork | fan | boolean | | false | DEVICE_DATA | 258 | 1 | 1 | +| ignwork | ignition | boolean | | false | DEVICE_DATA | 259 | 1 | 1 | +| oilpreheat | oil preheating | boolean | | false | DEVICE_DATA | 260 | 1 | 1 | uint8 -| burnminpower | burner min power | uint8 (>=0<=0) | % | true | DEVICE_DATA | 260 | 1 | 1 | +| burnminpower | burner min power | uint8 (>=0<=0) | % | true | DEVICE_DATA | 261 | 1 | 1 | uint8 -| burnmaxpower | burner max power | uint8 (>=0<=254) | % | true | DEVICE_DATA | 261 | 1 | 1 | +| burnmaxpower | burner max power | uint8 (>=0<=254) | % | true | DEVICE_DATA | 262 | 1 | 1 | uint8 -| burnminperiod | burner min period | uint8 (>=0<=120) | minutes | true | DEVICE_DATA | 262 | 1 | 1 | -| absburnpow | burner current power (absolute) | uint8 | % | false | DEVICE_DATA | 263 | 1 | 1 | -| heatblock | Heatblock temperature | uint16 | C | false | DEVICE_DATA | 264 | 1 | 1/10 | +| burnminperiod | burner min period | uint8 (>=0<=120) | minutes | true | DEVICE_DATA | 263 | 1 | 1 | +| absburnpow | burner current power (absolute) | uint8 | % | false | DEVICE_DATA | 264 | 1 | 1 | +| heatblock | Heatblock temperature | uint16 | C | false | DEVICE_DATA | 265 | 1 | 1/10 | int8 -| boilhyston | hysteresis on temperature | int8 (>=-20<=0) | C | true | DEVICE_DATA | 265 | 1 | 1 | +| boilhyston | hysteresis on temperature | int8 (>=-20<=0) | C | true | DEVICE_DATA | 266 | 1 | 1 | int8 -| boilhystoff | hysteresis off temperature | int8 (>=0<=20) | C | true | DEVICE_DATA | 266 | 1 | 1 | +| boilhystoff | hysteresis off temperature | int8 (>=0<=20) | C | true | DEVICE_DATA | 267 | 1 | 1 | int8 -| boil2hyston | hysteresis stage 2 on temperature | int8 (>=-20<=0) | C | true | DEVICE_DATA | 267 | 1 | 1 | +| boil2hyston | hysteresis stage 2 on temperature | int8 (>=-20<=0) | C | true | DEVICE_DATA | 268 | 1 | 1 | int8 -| boil2hystoff | hysteresis stage 2 off temperature | int8 (>=0<=20) | C | true | DEVICE_DATA | 268 | 1 | 1 | -| curveon | heatingcurve on | boolean | | true | DEVICE_DATA | 269 | 1 | 1 | +| boil2hystoff | hysteresis stage 2 off temperature | int8 (>=0<=20) | C | true | DEVICE_DATA | 269 | 1 | 1 | +| curveon | heatingcurve on | boolean | | true | DEVICE_DATA | 270 | 1 | 1 | uint8 -| curvebase | heatingcurve base | uint8 (>=20<=90) | C | true | DEVICE_DATA | 270 | 1 | 1 | +| curvebase | heatingcurve base | uint8 (>=20<=90) | C | true | DEVICE_DATA | 271 | 1 | 1 | uint8 -| curveend | heatingcurve end | uint8 (>=20<=90) | C | true | DEVICE_DATA | 271 | 1 | 1 | +| curveend | heatingcurve end | uint8 (>=20<=90) | C | true | DEVICE_DATA | 272 | 1 | 1 | uint8 -| summertemp | summer temperature | uint8 (>=0<=45) | C | true | DEVICE_DATA | 272 | 1 | 1 | -| nofrostmode | nofrost mode | boolean | | true | DEVICE_DATA | 273 | 1 | 1 | +| summertemp | summer temperature | uint8 (>=0<=45) | C | true | DEVICE_DATA | 273 | 1 | 1 | +| nofrostmode | nofrost mode | boolean | | true | DEVICE_DATA | 274 | 1 | 1 | uint8 -| nofrosttemp | nofrost temperature | uint8 (>=0<=10) | C | true | DEVICE_DATA | 274 | 1 | 1 | +| nofrosttemp | nofrost temperature | uint8 (>=0<=10) | C | true | DEVICE_DATA | 275 | 1 | 1 | | heatingactivated | heating activated | boolean | | true | DEVICE_DATA | 14 | 1 | 1 | uint8 | heatingtemp | heating temperature | uint8 (>=0<=90) | C | true | DEVICE_DATA | 15 | 1 | 1 | @@ -1330,20 +1337,21 @@ uint16 | emergencyops | emergency operation | boolean | | true | DEVICE_DATA | 78 | 1 | 1 | uint8 | emergencytemp | emergency temperature | uint8 (>=15<=70) | C | true | DEVICE_DATA | 79 | 1 | 1 | -| pc0flow | Flow PC0 | int16 | l/h | false | DEVICE_DATA | 80 | 1 | 1 | -| pc1flow | Flow PC1 | int16 | l/h | false | DEVICE_DATA | 81 | 1 | 1 | -| pc1on | PC1 | boolean | | false | DEVICE_DATA | 82 | 1 | 1 | -| pc1rate | PC1 rate | uint8 | % | false | DEVICE_DATA | 83 | 1 | 1 | +| pc0lpm | Flow PC0 | uint16 | l/min | false | DEVICE_DATA | 80 | 1 | 1/10 | +| pc0flow | Flow PC0 | uint16 | l/h | false | DEVICE_DATA | 81 | 1 | 1 | +| pc1flow | Flow PC1 | uint16 | l/h | false | DEVICE_DATA | 82 | 1 | 1 | +| pc1on | PC1 | boolean | | false | DEVICE_DATA | 83 | 1 | 1 | +| pc1rate | PC1 rate | uint8 | % | false | DEVICE_DATA | 84 | 1 | 1 | uint8 -| pumpkickhour | pump kick hour | uint8 (>=0<=23) | hours | true | DEVICE_DATA | 84 | 1 | 1 | -| pumpkickday | pump kick day | enum | | true | DEVICE_DATA | 85 | 1 | 1 | +| pumpkickhour | pump kick hour | uint8 (>=0<=23) | hours | true | DEVICE_DATA | 85 | 1 | 1 | +| pumpkickday | pump kick day | enum | | true | DEVICE_DATA | 86 | 1 | 1 | uint16 -| pumpkickdelay | pump kick delay | uint16 (>=0<=32767) | minutes | true | DEVICE_DATA | 86 | 1 | 1 | -| meterheat | meter heating | uint24 | kWh | false | DEVICE_DATA | 100 | 2 | 1/10 | +| pumpkickdelay | pump kick delay | uint16 (>=0<=32767) | minutes | true | DEVICE_DATA | 87 | 1 | 1 | +| meterheat | meter heating | uint24 | kWh | false | DEVICE_DATA | 101 | 2 | 1/10 | | dhw.meter | meter | uint24 | kWh | false | DHW | 2 | 2 | 1/10 | -| gasmeterheat | gas meter heating | uint24 | kWh | false | DEVICE_DATA | 275 | 2 | 1/10 | +| gasmeterheat | gas meter heating | uint24 | kWh | false | DEVICE_DATA | 276 | 2 | 1/10 | | dhw.gasmeter | gas meter | uint24 | kWh | false | DHW | 71 | 2 | 1/10 | -| nrgheat2 | energy heating 2 | uint24 | kWh | false | DEVICE_DATA | 277 | 2 | 1/10 | +| nrgheat2 | energy heating 2 | uint24 | kWh | false | DEVICE_DATA | 278 | 2 | 1/10 | | dhw.nrg2 | energy 2 | uint24 | kWh | false | DHW | 73 | 2 | 1/10 | | dhw.tapactivated | turn on/off | boolean | | true | DHW | 28 | 1 | 1 | | dhw.settemp | set temperature | uint8 | C | false | DHW | 29 | 1 | 1 | @@ -1397,10 +1405,10 @@ uint8 | dhw.starts | starts | uint24 | | false | DHW | 67 | 2 | 1 | | dhw.workm | active time | time | minutes | false | DHW | 69 | 2 | 1 | uint8 -| nompower | nominal Power | uint8 (>=0<=0) | kW | true | DEVICE_DATA | 279 | 1 | 1 | -| nrgtotal | total energy | uint24 | kWh | false | DEVICE_DATA | 88 | 2 | 1/100 | +| nompower | nominal Power | uint8 (>=0<=0) | kW | true | DEVICE_DATA | 280 | 1 | 1 | +| nrgtotal | total energy | uint24 | kWh | false | DEVICE_DATA | 89 | 2 | 1/100 | uint24 -| nrgheat | energy heating | uint24 (>=0<=10000000) | kWh | true | DEVICE_DATA | 90 | 2 | 1/100 | +| nrgheat | energy heating | uint24 (>=0<=10000000) | kWh | true | DEVICE_DATA | 91 | 2 | 1/100 | uint24 | dhw.nrg | energy | uint24 (>=0<=10000000) | kWh | true | DHW | 0 | 2 | 1/100 | @@ -1423,39 +1431,39 @@ uint8 | syspress | system pressure | uint8 | bar | false | DEVICE_DATA | 11 | 1 | 1/10 | | boiltemp | actual boiler temperature | uint16 | C | false | DEVICE_DATA | 12 | 1 | 1/10 | | headertemp | low loss header | uint16 | C | false | DEVICE_DATA | 13 | 1 | 1/10 | -| exhausttemp | exhaust temperature | uint16 | C | false | DEVICE_DATA | 253 | 1 | 1/10 | -| burngas | gas | boolean | | false | DEVICE_DATA | 254 | 1 | 1 | -| burngas2 | gas stage 2 | boolean | | false | DEVICE_DATA | 255 | 1 | 1 | -| flamecurr | flame current | uint16 | µA | false | DEVICE_DATA | 256 | 1 | 1/10 | -| fanwork | fan | boolean | | false | DEVICE_DATA | 257 | 1 | 1 | -| ignwork | ignition | boolean | | false | DEVICE_DATA | 258 | 1 | 1 | -| oilpreheat | oil preheating | boolean | | false | DEVICE_DATA | 259 | 1 | 1 | +| exhausttemp | exhaust temperature | uint16 | C | false | DEVICE_DATA | 254 | 1 | 1/10 | +| burngas | gas | boolean | | false | DEVICE_DATA | 255 | 1 | 1 | +| burngas2 | gas stage 2 | boolean | | false | DEVICE_DATA | 256 | 1 | 1 | +| flamecurr | flame current | uint16 | µA | false | DEVICE_DATA | 257 | 1 | 1/10 | +| fanwork | fan | boolean | | false | DEVICE_DATA | 258 | 1 | 1 | +| ignwork | ignition | boolean | | false | DEVICE_DATA | 259 | 1 | 1 | +| oilpreheat | oil preheating | boolean | | false | DEVICE_DATA | 260 | 1 | 1 | uint8 -| burnminpower | burner min power | uint8 (>=0<=0) | % | true | DEVICE_DATA | 260 | 1 | 1 | +| burnminpower | burner min power | uint8 (>=0<=0) | % | true | DEVICE_DATA | 261 | 1 | 1 | uint8 -| burnmaxpower | burner max power | uint8 (>=0<=254) | % | true | DEVICE_DATA | 261 | 1 | 1 | +| burnmaxpower | burner max power | uint8 (>=0<=254) | % | true | DEVICE_DATA | 262 | 1 | 1 | uint8 -| burnminperiod | burner min period | uint8 (>=0<=120) | minutes | true | DEVICE_DATA | 262 | 1 | 1 | -| absburnpow | burner current power (absolute) | uint8 | % | false | DEVICE_DATA | 263 | 1 | 1 | -| heatblock | Heatblock temperature | uint16 | C | false | DEVICE_DATA | 264 | 1 | 1/10 | +| burnminperiod | burner min period | uint8 (>=0<=120) | minutes | true | DEVICE_DATA | 263 | 1 | 1 | +| absburnpow | burner current power (absolute) | uint8 | % | false | DEVICE_DATA | 264 | 1 | 1 | +| heatblock | Heatblock temperature | uint16 | C | false | DEVICE_DATA | 265 | 1 | 1/10 | int8 -| boilhyston | hysteresis on temperature | int8 (>=-20<=0) | C | true | DEVICE_DATA | 265 | 1 | 1 | +| boilhyston | hysteresis on temperature | int8 (>=-20<=0) | C | true | DEVICE_DATA | 266 | 1 | 1 | int8 -| boilhystoff | hysteresis off temperature | int8 (>=0<=20) | C | true | DEVICE_DATA | 266 | 1 | 1 | +| boilhystoff | hysteresis off temperature | int8 (>=0<=20) | C | true | DEVICE_DATA | 267 | 1 | 1 | int8 -| boil2hyston | hysteresis stage 2 on temperature | int8 (>=-20<=0) | C | true | DEVICE_DATA | 267 | 1 | 1 | +| boil2hyston | hysteresis stage 2 on temperature | int8 (>=-20<=0) | C | true | DEVICE_DATA | 268 | 1 | 1 | int8 -| boil2hystoff | hysteresis stage 2 off temperature | int8 (>=0<=20) | C | true | DEVICE_DATA | 268 | 1 | 1 | -| curveon | heatingcurve on | boolean | | true | DEVICE_DATA | 269 | 1 | 1 | +| boil2hystoff | hysteresis stage 2 off temperature | int8 (>=0<=20) | C | true | DEVICE_DATA | 269 | 1 | 1 | +| curveon | heatingcurve on | boolean | | true | DEVICE_DATA | 270 | 1 | 1 | uint8 -| curvebase | heatingcurve base | uint8 (>=20<=90) | C | true | DEVICE_DATA | 270 | 1 | 1 | +| curvebase | heatingcurve base | uint8 (>=20<=90) | C | true | DEVICE_DATA | 271 | 1 | 1 | uint8 -| curveend | heatingcurve end | uint8 (>=20<=90) | C | true | DEVICE_DATA | 271 | 1 | 1 | +| curveend | heatingcurve end | uint8 (>=20<=90) | C | true | DEVICE_DATA | 272 | 1 | 1 | uint8 -| summertemp | summer temperature | uint8 (>=0<=45) | C | true | DEVICE_DATA | 272 | 1 | 1 | -| nofrostmode | nofrost mode | boolean | | true | DEVICE_DATA | 273 | 1 | 1 | +| summertemp | summer temperature | uint8 (>=0<=45) | C | true | DEVICE_DATA | 273 | 1 | 1 | +| nofrostmode | nofrost mode | boolean | | true | DEVICE_DATA | 274 | 1 | 1 | uint8 -| nofrosttemp | nofrost temperature | uint8 (>=0<=10) | C | true | DEVICE_DATA | 274 | 1 | 1 | +| nofrosttemp | nofrost temperature | uint8 (>=0<=10) | C | true | DEVICE_DATA | 275 | 1 | 1 | | heatingactivated | heating activated | boolean | | true | DEVICE_DATA | 14 | 1 | 1 | uint8 | heatingtemp | heating temperature | uint8 (>=0<=90) | C | true | DEVICE_DATA | 15 | 1 | 1 | @@ -1490,20 +1498,21 @@ uint16 | emergencyops | emergency operation | boolean | | true | DEVICE_DATA | 78 | 1 | 1 | uint8 | emergencytemp | emergency temperature | uint8 (>=15<=70) | C | true | DEVICE_DATA | 79 | 1 | 1 | -| pc0flow | Flow PC0 | int16 | l/h | false | DEVICE_DATA | 80 | 1 | 1 | -| pc1flow | Flow PC1 | int16 | l/h | false | DEVICE_DATA | 81 | 1 | 1 | -| pc1on | PC1 | boolean | | false | DEVICE_DATA | 82 | 1 | 1 | -| pc1rate | PC1 rate | uint8 | % | false | DEVICE_DATA | 83 | 1 | 1 | +| pc0lpm | Flow PC0 | uint16 | l/min | false | DEVICE_DATA | 80 | 1 | 1/10 | +| pc0flow | Flow PC0 | uint16 | l/h | false | DEVICE_DATA | 81 | 1 | 1 | +| pc1flow | Flow PC1 | uint16 | l/h | false | DEVICE_DATA | 82 | 1 | 1 | +| pc1on | PC1 | boolean | | false | DEVICE_DATA | 83 | 1 | 1 | +| pc1rate | PC1 rate | uint8 | % | false | DEVICE_DATA | 84 | 1 | 1 | uint8 -| pumpkickhour | pump kick hour | uint8 (>=0<=23) | hours | true | DEVICE_DATA | 84 | 1 | 1 | -| pumpkickday | pump kick day | enum | | true | DEVICE_DATA | 85 | 1 | 1 | +| pumpkickhour | pump kick hour | uint8 (>=0<=23) | hours | true | DEVICE_DATA | 85 | 1 | 1 | +| pumpkickday | pump kick day | enum | | true | DEVICE_DATA | 86 | 1 | 1 | uint16 -| pumpkickdelay | pump kick delay | uint16 (>=0<=32767) | minutes | true | DEVICE_DATA | 86 | 1 | 1 | -| meterheat | meter heating | uint24 | kWh | false | DEVICE_DATA | 100 | 2 | 1/10 | +| pumpkickdelay | pump kick delay | uint16 (>=0<=32767) | minutes | true | DEVICE_DATA | 87 | 1 | 1 | +| meterheat | meter heating | uint24 | kWh | false | DEVICE_DATA | 101 | 2 | 1/10 | | dhw.meter | meter | uint24 | kWh | false | DHW | 2 | 2 | 1/10 | -| gasmeterheat | gas meter heating | uint24 | kWh | false | DEVICE_DATA | 275 | 2 | 1/10 | +| gasmeterheat | gas meter heating | uint24 | kWh | false | DEVICE_DATA | 276 | 2 | 1/10 | | dhw.gasmeter | gas meter | uint24 | kWh | false | DHW | 71 | 2 | 1/10 | -| nrgheat2 | energy heating 2 | uint24 | kWh | false | DEVICE_DATA | 277 | 2 | 1/10 | +| nrgheat2 | energy heating 2 | uint24 | kWh | false | DEVICE_DATA | 278 | 2 | 1/10 | | dhw.nrg2 | energy 2 | uint24 | kWh | false | DHW | 73 | 2 | 1/10 | | dhw.tapactivated | turn on/off | boolean | | true | DHW | 28 | 1 | 1 | | dhw.settemp | set temperature | uint8 | C | false | DHW | 29 | 1 | 1 | @@ -1557,10 +1566,10 @@ uint8 | dhw.starts | starts | uint24 | | false | DHW | 67 | 2 | 1 | | dhw.workm | active time | time | minutes | false | DHW | 69 | 2 | 1 | uint8 -| nompower | nominal Power | uint8 (>=0<=0) | kW | true | DEVICE_DATA | 279 | 1 | 1 | -| nrgtotal | total energy | uint24 | kWh | false | DEVICE_DATA | 88 | 2 | 1/100 | +| nompower | nominal Power | uint8 (>=0<=0) | kW | true | DEVICE_DATA | 280 | 1 | 1 | +| nrgtotal | total energy | uint24 | kWh | false | DEVICE_DATA | 89 | 2 | 1/100 | uint24 -| nrgheat | energy heating | uint24 (>=0<=10000000) | kWh | true | DEVICE_DATA | 90 | 2 | 1/100 | +| nrgheat | energy heating | uint24 (>=0<=10000000) | kWh | true | DEVICE_DATA | 91 | 2 | 1/100 | uint24 | dhw.nrg | energy | uint24 (>=0<=10000000) | kWh | true | DHW | 0 | 2 | 1/100 | @@ -1583,39 +1592,39 @@ uint8 | syspress | system pressure | uint8 | bar | false | DEVICE_DATA | 11 | 1 | 1/10 | | boiltemp | actual boiler temperature | uint16 | C | false | DEVICE_DATA | 12 | 1 | 1/10 | | headertemp | low loss header | uint16 | C | false | DEVICE_DATA | 13 | 1 | 1/10 | -| exhausttemp | exhaust temperature | uint16 | C | false | DEVICE_DATA | 253 | 1 | 1/10 | -| burngas | gas | boolean | | false | DEVICE_DATA | 254 | 1 | 1 | -| burngas2 | gas stage 2 | boolean | | false | DEVICE_DATA | 255 | 1 | 1 | -| flamecurr | flame current | uint16 | µA | false | DEVICE_DATA | 256 | 1 | 1/10 | -| fanwork | fan | boolean | | false | DEVICE_DATA | 257 | 1 | 1 | -| ignwork | ignition | boolean | | false | DEVICE_DATA | 258 | 1 | 1 | -| oilpreheat | oil preheating | boolean | | false | DEVICE_DATA | 259 | 1 | 1 | +| exhausttemp | exhaust temperature | uint16 | C | false | DEVICE_DATA | 254 | 1 | 1/10 | +| burngas | gas | boolean | | false | DEVICE_DATA | 255 | 1 | 1 | +| burngas2 | gas stage 2 | boolean | | false | DEVICE_DATA | 256 | 1 | 1 | +| flamecurr | flame current | uint16 | µA | false | DEVICE_DATA | 257 | 1 | 1/10 | +| fanwork | fan | boolean | | false | DEVICE_DATA | 258 | 1 | 1 | +| ignwork | ignition | boolean | | false | DEVICE_DATA | 259 | 1 | 1 | +| oilpreheat | oil preheating | boolean | | false | DEVICE_DATA | 260 | 1 | 1 | uint8 -| burnminpower | burner min power | uint8 (>=0<=0) | % | true | DEVICE_DATA | 260 | 1 | 1 | +| burnminpower | burner min power | uint8 (>=0<=0) | % | true | DEVICE_DATA | 261 | 1 | 1 | uint8 -| burnmaxpower | burner max power | uint8 (>=0<=254) | % | true | DEVICE_DATA | 261 | 1 | 1 | +| burnmaxpower | burner max power | uint8 (>=0<=254) | % | true | DEVICE_DATA | 262 | 1 | 1 | uint8 -| burnminperiod | burner min period | uint8 (>=0<=120) | minutes | true | DEVICE_DATA | 262 | 1 | 1 | -| absburnpow | burner current power (absolute) | uint8 | % | false | DEVICE_DATA | 263 | 1 | 1 | -| heatblock | Heatblock temperature | uint16 | C | false | DEVICE_DATA | 264 | 1 | 1/10 | +| burnminperiod | burner min period | uint8 (>=0<=120) | minutes | true | DEVICE_DATA | 263 | 1 | 1 | +| absburnpow | burner current power (absolute) | uint8 | % | false | DEVICE_DATA | 264 | 1 | 1 | +| heatblock | Heatblock temperature | uint16 | C | false | DEVICE_DATA | 265 | 1 | 1/10 | int8 -| boilhyston | hysteresis on temperature | int8 (>=-20<=0) | C | true | DEVICE_DATA | 265 | 1 | 1 | +| boilhyston | hysteresis on temperature | int8 (>=-20<=0) | C | true | DEVICE_DATA | 266 | 1 | 1 | int8 -| boilhystoff | hysteresis off temperature | int8 (>=0<=20) | C | true | DEVICE_DATA | 266 | 1 | 1 | +| boilhystoff | hysteresis off temperature | int8 (>=0<=20) | C | true | DEVICE_DATA | 267 | 1 | 1 | int8 -| boil2hyston | hysteresis stage 2 on temperature | int8 (>=-20<=0) | C | true | DEVICE_DATA | 267 | 1 | 1 | +| boil2hyston | hysteresis stage 2 on temperature | int8 (>=-20<=0) | C | true | DEVICE_DATA | 268 | 1 | 1 | int8 -| boil2hystoff | hysteresis stage 2 off temperature | int8 (>=0<=20) | C | true | DEVICE_DATA | 268 | 1 | 1 | -| curveon | heatingcurve on | boolean | | true | DEVICE_DATA | 269 | 1 | 1 | +| boil2hystoff | hysteresis stage 2 off temperature | int8 (>=0<=20) | C | true | DEVICE_DATA | 269 | 1 | 1 | +| curveon | heatingcurve on | boolean | | true | DEVICE_DATA | 270 | 1 | 1 | uint8 -| curvebase | heatingcurve base | uint8 (>=20<=90) | C | true | DEVICE_DATA | 270 | 1 | 1 | +| curvebase | heatingcurve base | uint8 (>=20<=90) | C | true | DEVICE_DATA | 271 | 1 | 1 | uint8 -| curveend | heatingcurve end | uint8 (>=20<=90) | C | true | DEVICE_DATA | 271 | 1 | 1 | +| curveend | heatingcurve end | uint8 (>=20<=90) | C | true | DEVICE_DATA | 272 | 1 | 1 | uint8 -| summertemp | summer temperature | uint8 (>=0<=45) | C | true | DEVICE_DATA | 272 | 1 | 1 | -| nofrostmode | nofrost mode | boolean | | true | DEVICE_DATA | 273 | 1 | 1 | +| summertemp | summer temperature | uint8 (>=0<=45) | C | true | DEVICE_DATA | 273 | 1 | 1 | +| nofrostmode | nofrost mode | boolean | | true | DEVICE_DATA | 274 | 1 | 1 | uint8 -| nofrosttemp | nofrost temperature | uint8 (>=0<=10) | C | true | DEVICE_DATA | 274 | 1 | 1 | +| nofrosttemp | nofrost temperature | uint8 (>=0<=10) | C | true | DEVICE_DATA | 275 | 1 | 1 | | heatingactivated | heating activated | boolean | | true | DEVICE_DATA | 14 | 1 | 1 | uint8 | heatingtemp | heating temperature | uint8 (>=0<=90) | C | true | DEVICE_DATA | 15 | 1 | 1 | @@ -1650,20 +1659,21 @@ uint16 | emergencyops | emergency operation | boolean | | true | DEVICE_DATA | 78 | 1 | 1 | uint8 | emergencytemp | emergency temperature | uint8 (>=15<=70) | C | true | DEVICE_DATA | 79 | 1 | 1 | -| pc0flow | Flow PC0 | int16 | l/h | false | DEVICE_DATA | 80 | 1 | 1 | -| pc1flow | Flow PC1 | int16 | l/h | false | DEVICE_DATA | 81 | 1 | 1 | -| pc1on | PC1 | boolean | | false | DEVICE_DATA | 82 | 1 | 1 | -| pc1rate | PC1 rate | uint8 | % | false | DEVICE_DATA | 83 | 1 | 1 | +| pc0lpm | Flow PC0 | uint16 | l/min | false | DEVICE_DATA | 80 | 1 | 1/10 | +| pc0flow | Flow PC0 | uint16 | l/h | false | DEVICE_DATA | 81 | 1 | 1 | +| pc1flow | Flow PC1 | uint16 | l/h | false | DEVICE_DATA | 82 | 1 | 1 | +| pc1on | PC1 | boolean | | false | DEVICE_DATA | 83 | 1 | 1 | +| pc1rate | PC1 rate | uint8 | % | false | DEVICE_DATA | 84 | 1 | 1 | uint8 -| pumpkickhour | pump kick hour | uint8 (>=0<=23) | hours | true | DEVICE_DATA | 84 | 1 | 1 | -| pumpkickday | pump kick day | enum | | true | DEVICE_DATA | 85 | 1 | 1 | +| pumpkickhour | pump kick hour | uint8 (>=0<=23) | hours | true | DEVICE_DATA | 85 | 1 | 1 | +| pumpkickday | pump kick day | enum | | true | DEVICE_DATA | 86 | 1 | 1 | uint16 -| pumpkickdelay | pump kick delay | uint16 (>=0<=32767) | minutes | true | DEVICE_DATA | 86 | 1 | 1 | -| meterheat | meter heating | uint24 | kWh | false | DEVICE_DATA | 100 | 2 | 1/10 | +| pumpkickdelay | pump kick delay | uint16 (>=0<=32767) | minutes | true | DEVICE_DATA | 87 | 1 | 1 | +| meterheat | meter heating | uint24 | kWh | false | DEVICE_DATA | 101 | 2 | 1/10 | | dhw.meter | meter | uint24 | kWh | false | DHW | 2 | 2 | 1/10 | -| gasmeterheat | gas meter heating | uint24 | kWh | false | DEVICE_DATA | 275 | 2 | 1/10 | +| gasmeterheat | gas meter heating | uint24 | kWh | false | DEVICE_DATA | 276 | 2 | 1/10 | | dhw.gasmeter | gas meter | uint24 | kWh | false | DHW | 71 | 2 | 1/10 | -| nrgheat2 | energy heating 2 | uint24 | kWh | false | DEVICE_DATA | 277 | 2 | 1/10 | +| nrgheat2 | energy heating 2 | uint24 | kWh | false | DEVICE_DATA | 278 | 2 | 1/10 | | dhw.nrg2 | energy 2 | uint24 | kWh | false | DHW | 73 | 2 | 1/10 | | dhw.tapactivated | turn on/off | boolean | | true | DHW | 28 | 1 | 1 | | dhw.settemp | set temperature | uint8 | C | false | DHW | 29 | 1 | 1 | @@ -1717,10 +1727,10 @@ uint8 | dhw.starts | starts | uint24 | | false | DHW | 67 | 2 | 1 | | dhw.workm | active time | time | minutes | false | DHW | 69 | 2 | 1 | uint8 -| nompower | nominal Power | uint8 (>=0<=0) | kW | true | DEVICE_DATA | 279 | 1 | 1 | -| nrgtotal | total energy | uint24 | kWh | false | DEVICE_DATA | 88 | 2 | 1/100 | +| nompower | nominal Power | uint8 (>=0<=0) | kW | true | DEVICE_DATA | 280 | 1 | 1 | +| nrgtotal | total energy | uint24 | kWh | false | DEVICE_DATA | 89 | 2 | 1/100 | uint24 -| nrgheat | energy heating | uint24 (>=0<=10000000) | kWh | true | DEVICE_DATA | 90 | 2 | 1/100 | +| nrgheat | energy heating | uint24 (>=0<=10000000) | kWh | true | DEVICE_DATA | 91 | 2 | 1/100 | uint24 | dhw.nrg | energy | uint24 (>=0<=10000000) | kWh | true | DHW | 0 | 2 | 1/100 | @@ -1743,39 +1753,39 @@ uint8 | syspress | system pressure | uint8 | bar | false | DEVICE_DATA | 11 | 1 | 1/10 | | boiltemp | actual boiler temperature | uint16 | C | false | DEVICE_DATA | 12 | 1 | 1/10 | | headertemp | low loss header | uint16 | C | false | DEVICE_DATA | 13 | 1 | 1/10 | -| exhausttemp | exhaust temperature | uint16 | C | false | DEVICE_DATA | 253 | 1 | 1/10 | -| burngas | gas | boolean | | false | DEVICE_DATA | 254 | 1 | 1 | -| burngas2 | gas stage 2 | boolean | | false | DEVICE_DATA | 255 | 1 | 1 | -| flamecurr | flame current | uint16 | µA | false | DEVICE_DATA | 256 | 1 | 1/10 | -| fanwork | fan | boolean | | false | DEVICE_DATA | 257 | 1 | 1 | -| ignwork | ignition | boolean | | false | DEVICE_DATA | 258 | 1 | 1 | -| oilpreheat | oil preheating | boolean | | false | DEVICE_DATA | 259 | 1 | 1 | +| exhausttemp | exhaust temperature | uint16 | C | false | DEVICE_DATA | 254 | 1 | 1/10 | +| burngas | gas | boolean | | false | DEVICE_DATA | 255 | 1 | 1 | +| burngas2 | gas stage 2 | boolean | | false | DEVICE_DATA | 256 | 1 | 1 | +| flamecurr | flame current | uint16 | µA | false | DEVICE_DATA | 257 | 1 | 1/10 | +| fanwork | fan | boolean | | false | DEVICE_DATA | 258 | 1 | 1 | +| ignwork | ignition | boolean | | false | DEVICE_DATA | 259 | 1 | 1 | +| oilpreheat | oil preheating | boolean | | false | DEVICE_DATA | 260 | 1 | 1 | uint8 -| burnminpower | burner min power | uint8 (>=0<=0) | % | true | DEVICE_DATA | 260 | 1 | 1 | +| burnminpower | burner min power | uint8 (>=0<=0) | % | true | DEVICE_DATA | 261 | 1 | 1 | uint8 -| burnmaxpower | burner max power | uint8 (>=0<=254) | % | true | DEVICE_DATA | 261 | 1 | 1 | +| burnmaxpower | burner max power | uint8 (>=0<=254) | % | true | DEVICE_DATA | 262 | 1 | 1 | uint8 -| burnminperiod | burner min period | uint8 (>=0<=120) | minutes | true | DEVICE_DATA | 262 | 1 | 1 | -| absburnpow | burner current power (absolute) | uint8 | % | false | DEVICE_DATA | 263 | 1 | 1 | -| heatblock | Heatblock temperature | uint16 | C | false | DEVICE_DATA | 264 | 1 | 1/10 | +| burnminperiod | burner min period | uint8 (>=0<=120) | minutes | true | DEVICE_DATA | 263 | 1 | 1 | +| absburnpow | burner current power (absolute) | uint8 | % | false | DEVICE_DATA | 264 | 1 | 1 | +| heatblock | Heatblock temperature | uint16 | C | false | DEVICE_DATA | 265 | 1 | 1/10 | int8 -| boilhyston | hysteresis on temperature | int8 (>=-20<=0) | C | true | DEVICE_DATA | 265 | 1 | 1 | +| boilhyston | hysteresis on temperature | int8 (>=-20<=0) | C | true | DEVICE_DATA | 266 | 1 | 1 | int8 -| boilhystoff | hysteresis off temperature | int8 (>=0<=20) | C | true | DEVICE_DATA | 266 | 1 | 1 | +| boilhystoff | hysteresis off temperature | int8 (>=0<=20) | C | true | DEVICE_DATA | 267 | 1 | 1 | int8 -| boil2hyston | hysteresis stage 2 on temperature | int8 (>=-20<=0) | C | true | DEVICE_DATA | 267 | 1 | 1 | +| boil2hyston | hysteresis stage 2 on temperature | int8 (>=-20<=0) | C | true | DEVICE_DATA | 268 | 1 | 1 | int8 -| boil2hystoff | hysteresis stage 2 off temperature | int8 (>=0<=20) | C | true | DEVICE_DATA | 268 | 1 | 1 | -| curveon | heatingcurve on | boolean | | true | DEVICE_DATA | 269 | 1 | 1 | +| boil2hystoff | hysteresis stage 2 off temperature | int8 (>=0<=20) | C | true | DEVICE_DATA | 269 | 1 | 1 | +| curveon | heatingcurve on | boolean | | true | DEVICE_DATA | 270 | 1 | 1 | uint8 -| curvebase | heatingcurve base | uint8 (>=20<=90) | C | true | DEVICE_DATA | 270 | 1 | 1 | +| curvebase | heatingcurve base | uint8 (>=20<=90) | C | true | DEVICE_DATA | 271 | 1 | 1 | uint8 -| curveend | heatingcurve end | uint8 (>=20<=90) | C | true | DEVICE_DATA | 271 | 1 | 1 | +| curveend | heatingcurve end | uint8 (>=20<=90) | C | true | DEVICE_DATA | 272 | 1 | 1 | uint8 -| summertemp | summer temperature | uint8 (>=0<=45) | C | true | DEVICE_DATA | 272 | 1 | 1 | -| nofrostmode | nofrost mode | boolean | | true | DEVICE_DATA | 273 | 1 | 1 | +| summertemp | summer temperature | uint8 (>=0<=45) | C | true | DEVICE_DATA | 273 | 1 | 1 | +| nofrostmode | nofrost mode | boolean | | true | DEVICE_DATA | 274 | 1 | 1 | uint8 -| nofrosttemp | nofrost temperature | uint8 (>=0<=10) | C | true | DEVICE_DATA | 274 | 1 | 1 | +| nofrosttemp | nofrost temperature | uint8 (>=0<=10) | C | true | DEVICE_DATA | 275 | 1 | 1 | | heatingactivated | heating activated | boolean | | true | DEVICE_DATA | 14 | 1 | 1 | uint8 | heatingtemp | heating temperature | uint8 (>=0<=90) | C | true | DEVICE_DATA | 15 | 1 | 1 | @@ -1810,20 +1820,21 @@ uint16 | emergencyops | emergency operation | boolean | | true | DEVICE_DATA | 78 | 1 | 1 | uint8 | emergencytemp | emergency temperature | uint8 (>=15<=70) | C | true | DEVICE_DATA | 79 | 1 | 1 | -| pc0flow | Flow PC0 | int16 | l/h | false | DEVICE_DATA | 80 | 1 | 1 | -| pc1flow | Flow PC1 | int16 | l/h | false | DEVICE_DATA | 81 | 1 | 1 | -| pc1on | PC1 | boolean | | false | DEVICE_DATA | 82 | 1 | 1 | -| pc1rate | PC1 rate | uint8 | % | false | DEVICE_DATA | 83 | 1 | 1 | +| pc0lpm | Flow PC0 | uint16 | l/min | false | DEVICE_DATA | 80 | 1 | 1/10 | +| pc0flow | Flow PC0 | uint16 | l/h | false | DEVICE_DATA | 81 | 1 | 1 | +| pc1flow | Flow PC1 | uint16 | l/h | false | DEVICE_DATA | 82 | 1 | 1 | +| pc1on | PC1 | boolean | | false | DEVICE_DATA | 83 | 1 | 1 | +| pc1rate | PC1 rate | uint8 | % | false | DEVICE_DATA | 84 | 1 | 1 | uint8 -| pumpkickhour | pump kick hour | uint8 (>=0<=23) | hours | true | DEVICE_DATA | 84 | 1 | 1 | -| pumpkickday | pump kick day | enum | | true | DEVICE_DATA | 85 | 1 | 1 | +| pumpkickhour | pump kick hour | uint8 (>=0<=23) | hours | true | DEVICE_DATA | 85 | 1 | 1 | +| pumpkickday | pump kick day | enum | | true | DEVICE_DATA | 86 | 1 | 1 | uint16 -| pumpkickdelay | pump kick delay | uint16 (>=0<=32767) | minutes | true | DEVICE_DATA | 86 | 1 | 1 | -| meterheat | meter heating | uint24 | kWh | false | DEVICE_DATA | 100 | 2 | 1/10 | +| pumpkickdelay | pump kick delay | uint16 (>=0<=32767) | minutes | true | DEVICE_DATA | 87 | 1 | 1 | +| meterheat | meter heating | uint24 | kWh | false | DEVICE_DATA | 101 | 2 | 1/10 | | dhw.meter | meter | uint24 | kWh | false | DHW | 2 | 2 | 1/10 | -| gasmeterheat | gas meter heating | uint24 | kWh | false | DEVICE_DATA | 275 | 2 | 1/10 | +| gasmeterheat | gas meter heating | uint24 | kWh | false | DEVICE_DATA | 276 | 2 | 1/10 | | dhw.gasmeter | gas meter | uint24 | kWh | false | DHW | 71 | 2 | 1/10 | -| nrgheat2 | energy heating 2 | uint24 | kWh | false | DEVICE_DATA | 277 | 2 | 1/10 | +| nrgheat2 | energy heating 2 | uint24 | kWh | false | DEVICE_DATA | 278 | 2 | 1/10 | | dhw.nrg2 | energy 2 | uint24 | kWh | false | DHW | 73 | 2 | 1/10 | | dhw.tapactivated | turn on/off | boolean | | true | DHW | 28 | 1 | 1 | | dhw.settemp | set temperature | uint8 | C | false | DHW | 29 | 1 | 1 | @@ -1877,10 +1888,10 @@ uint8 | dhw.starts | starts | uint24 | | false | DHW | 67 | 2 | 1 | | dhw.workm | active time | time | minutes | false | DHW | 69 | 2 | 1 | uint8 -| nompower | nominal Power | uint8 (>=0<=0) | kW | true | DEVICE_DATA | 279 | 1 | 1 | -| nrgtotal | total energy | uint24 | kWh | false | DEVICE_DATA | 88 | 2 | 1/100 | +| nompower | nominal Power | uint8 (>=0<=0) | kW | true | DEVICE_DATA | 280 | 1 | 1 | +| nrgtotal | total energy | uint24 | kWh | false | DEVICE_DATA | 89 | 2 | 1/100 | uint24 -| nrgheat | energy heating | uint24 (>=0<=10000000) | kWh | true | DEVICE_DATA | 90 | 2 | 1/100 | +| nrgheat | energy heating | uint24 (>=0<=10000000) | kWh | true | DEVICE_DATA | 91 | 2 | 1/100 | uint24 | dhw.nrg | energy | uint24 (>=0<=10000000) | kWh | true | DHW | 0 | 2 | 1/100 | @@ -1903,39 +1914,39 @@ uint8 | syspress | system pressure | uint8 | bar | false | DEVICE_DATA | 11 | 1 | 1/10 | | boiltemp | actual boiler temperature | uint16 | C | false | DEVICE_DATA | 12 | 1 | 1/10 | | headertemp | low loss header | uint16 | C | false | DEVICE_DATA | 13 | 1 | 1/10 | -| exhausttemp | exhaust temperature | uint16 | C | false | DEVICE_DATA | 253 | 1 | 1/10 | -| burngas | gas | boolean | | false | DEVICE_DATA | 254 | 1 | 1 | -| burngas2 | gas stage 2 | boolean | | false | DEVICE_DATA | 255 | 1 | 1 | -| flamecurr | flame current | uint16 | µA | false | DEVICE_DATA | 256 | 1 | 1/10 | -| fanwork | fan | boolean | | false | DEVICE_DATA | 257 | 1 | 1 | -| ignwork | ignition | boolean | | false | DEVICE_DATA | 258 | 1 | 1 | -| oilpreheat | oil preheating | boolean | | false | DEVICE_DATA | 259 | 1 | 1 | +| exhausttemp | exhaust temperature | uint16 | C | false | DEVICE_DATA | 254 | 1 | 1/10 | +| burngas | gas | boolean | | false | DEVICE_DATA | 255 | 1 | 1 | +| burngas2 | gas stage 2 | boolean | | false | DEVICE_DATA | 256 | 1 | 1 | +| flamecurr | flame current | uint16 | µA | false | DEVICE_DATA | 257 | 1 | 1/10 | +| fanwork | fan | boolean | | false | DEVICE_DATA | 258 | 1 | 1 | +| ignwork | ignition | boolean | | false | DEVICE_DATA | 259 | 1 | 1 | +| oilpreheat | oil preheating | boolean | | false | DEVICE_DATA | 260 | 1 | 1 | uint8 -| burnminpower | burner min power | uint8 (>=0<=0) | % | true | DEVICE_DATA | 260 | 1 | 1 | +| burnminpower | burner min power | uint8 (>=0<=0) | % | true | DEVICE_DATA | 261 | 1 | 1 | uint8 -| burnmaxpower | burner max power | uint8 (>=0<=254) | % | true | DEVICE_DATA | 261 | 1 | 1 | +| burnmaxpower | burner max power | uint8 (>=0<=254) | % | true | DEVICE_DATA | 262 | 1 | 1 | uint8 -| burnminperiod | burner min period | uint8 (>=0<=120) | minutes | true | DEVICE_DATA | 262 | 1 | 1 | -| absburnpow | burner current power (absolute) | uint8 | % | false | DEVICE_DATA | 263 | 1 | 1 | -| heatblock | Heatblock temperature | uint16 | C | false | DEVICE_DATA | 264 | 1 | 1/10 | +| burnminperiod | burner min period | uint8 (>=0<=120) | minutes | true | DEVICE_DATA | 263 | 1 | 1 | +| absburnpow | burner current power (absolute) | uint8 | % | false | DEVICE_DATA | 264 | 1 | 1 | +| heatblock | Heatblock temperature | uint16 | C | false | DEVICE_DATA | 265 | 1 | 1/10 | int8 -| boilhyston | hysteresis on temperature | int8 (>=-20<=0) | C | true | DEVICE_DATA | 265 | 1 | 1 | +| boilhyston | hysteresis on temperature | int8 (>=-20<=0) | C | true | DEVICE_DATA | 266 | 1 | 1 | int8 -| boilhystoff | hysteresis off temperature | int8 (>=0<=20) | C | true | DEVICE_DATA | 266 | 1 | 1 | +| boilhystoff | hysteresis off temperature | int8 (>=0<=20) | C | true | DEVICE_DATA | 267 | 1 | 1 | int8 -| boil2hyston | hysteresis stage 2 on temperature | int8 (>=-20<=0) | C | true | DEVICE_DATA | 267 | 1 | 1 | +| boil2hyston | hysteresis stage 2 on temperature | int8 (>=-20<=0) | C | true | DEVICE_DATA | 268 | 1 | 1 | int8 -| boil2hystoff | hysteresis stage 2 off temperature | int8 (>=0<=20) | C | true | DEVICE_DATA | 268 | 1 | 1 | -| curveon | heatingcurve on | boolean | | true | DEVICE_DATA | 269 | 1 | 1 | +| boil2hystoff | hysteresis stage 2 off temperature | int8 (>=0<=20) | C | true | DEVICE_DATA | 269 | 1 | 1 | +| curveon | heatingcurve on | boolean | | true | DEVICE_DATA | 270 | 1 | 1 | uint8 -| curvebase | heatingcurve base | uint8 (>=20<=90) | C | true | DEVICE_DATA | 270 | 1 | 1 | +| curvebase | heatingcurve base | uint8 (>=20<=90) | C | true | DEVICE_DATA | 271 | 1 | 1 | uint8 -| curveend | heatingcurve end | uint8 (>=20<=90) | C | true | DEVICE_DATA | 271 | 1 | 1 | +| curveend | heatingcurve end | uint8 (>=20<=90) | C | true | DEVICE_DATA | 272 | 1 | 1 | uint8 -| summertemp | summer temperature | uint8 (>=0<=45) | C | true | DEVICE_DATA | 272 | 1 | 1 | -| nofrostmode | nofrost mode | boolean | | true | DEVICE_DATA | 273 | 1 | 1 | +| summertemp | summer temperature | uint8 (>=0<=45) | C | true | DEVICE_DATA | 273 | 1 | 1 | +| nofrostmode | nofrost mode | boolean | | true | DEVICE_DATA | 274 | 1 | 1 | uint8 -| nofrosttemp | nofrost temperature | uint8 (>=0<=10) | C | true | DEVICE_DATA | 274 | 1 | 1 | +| nofrosttemp | nofrost temperature | uint8 (>=0<=10) | C | true | DEVICE_DATA | 275 | 1 | 1 | | heatingactivated | heating activated | boolean | | true | DEVICE_DATA | 14 | 1 | 1 | uint8 | heatingtemp | heating temperature | uint8 (>=0<=90) | C | true | DEVICE_DATA | 15 | 1 | 1 | @@ -1970,20 +1981,21 @@ uint16 | emergencyops | emergency operation | boolean | | true | DEVICE_DATA | 78 | 1 | 1 | uint8 | emergencytemp | emergency temperature | uint8 (>=15<=70) | C | true | DEVICE_DATA | 79 | 1 | 1 | -| pc0flow | Flow PC0 | int16 | l/h | false | DEVICE_DATA | 80 | 1 | 1 | -| pc1flow | Flow PC1 | int16 | l/h | false | DEVICE_DATA | 81 | 1 | 1 | -| pc1on | PC1 | boolean | | false | DEVICE_DATA | 82 | 1 | 1 | -| pc1rate | PC1 rate | uint8 | % | false | DEVICE_DATA | 83 | 1 | 1 | +| pc0lpm | Flow PC0 | uint16 | l/min | false | DEVICE_DATA | 80 | 1 | 1/10 | +| pc0flow | Flow PC0 | uint16 | l/h | false | DEVICE_DATA | 81 | 1 | 1 | +| pc1flow | Flow PC1 | uint16 | l/h | false | DEVICE_DATA | 82 | 1 | 1 | +| pc1on | PC1 | boolean | | false | DEVICE_DATA | 83 | 1 | 1 | +| pc1rate | PC1 rate | uint8 | % | false | DEVICE_DATA | 84 | 1 | 1 | uint8 -| pumpkickhour | pump kick hour | uint8 (>=0<=23) | hours | true | DEVICE_DATA | 84 | 1 | 1 | -| pumpkickday | pump kick day | enum | | true | DEVICE_DATA | 85 | 1 | 1 | +| pumpkickhour | pump kick hour | uint8 (>=0<=23) | hours | true | DEVICE_DATA | 85 | 1 | 1 | +| pumpkickday | pump kick day | enum | | true | DEVICE_DATA | 86 | 1 | 1 | uint16 -| pumpkickdelay | pump kick delay | uint16 (>=0<=32767) | minutes | true | DEVICE_DATA | 86 | 1 | 1 | -| meterheat | meter heating | uint24 | kWh | false | DEVICE_DATA | 100 | 2 | 1/10 | +| pumpkickdelay | pump kick delay | uint16 (>=0<=32767) | minutes | true | DEVICE_DATA | 87 | 1 | 1 | +| meterheat | meter heating | uint24 | kWh | false | DEVICE_DATA | 101 | 2 | 1/10 | | dhw.meter | meter | uint24 | kWh | false | DHW | 2 | 2 | 1/10 | -| gasmeterheat | gas meter heating | uint24 | kWh | false | DEVICE_DATA | 275 | 2 | 1/10 | +| gasmeterheat | gas meter heating | uint24 | kWh | false | DEVICE_DATA | 276 | 2 | 1/10 | | dhw.gasmeter | gas meter | uint24 | kWh | false | DHW | 71 | 2 | 1/10 | -| nrgheat2 | energy heating 2 | uint24 | kWh | false | DEVICE_DATA | 277 | 2 | 1/10 | +| nrgheat2 | energy heating 2 | uint24 | kWh | false | DEVICE_DATA | 278 | 2 | 1/10 | | dhw.nrg2 | energy 2 | uint24 | kWh | false | DHW | 73 | 2 | 1/10 | | dhw.tapactivated | turn on/off | boolean | | true | DHW | 28 | 1 | 1 | | dhw.settemp | set temperature | uint8 | C | false | DHW | 29 | 1 | 1 | @@ -2037,10 +2049,10 @@ uint8 | dhw.starts | starts | uint24 | | false | DHW | 67 | 2 | 1 | | dhw.workm | active time | time | minutes | false | DHW | 69 | 2 | 1 | uint8 -| nompower | nominal Power | uint8 (>=0<=0) | kW | true | DEVICE_DATA | 279 | 1 | 1 | -| nrgtotal | total energy | uint24 | kWh | false | DEVICE_DATA | 88 | 2 | 1/100 | +| nompower | nominal Power | uint8 (>=0<=0) | kW | true | DEVICE_DATA | 280 | 1 | 1 | +| nrgtotal | total energy | uint24 | kWh | false | DEVICE_DATA | 89 | 2 | 1/100 | uint24 -| nrgheat | energy heating | uint24 (>=0<=10000000) | kWh | true | DEVICE_DATA | 90 | 2 | 1/100 | +| nrgheat | energy heating | uint24 (>=0<=10000000) | kWh | true | DEVICE_DATA | 91 | 2 | 1/100 | uint24 | dhw.nrg | energy | uint24 (>=0<=10000000) | kWh | true | DHW | 0 | 2 | 1/100 | @@ -2063,39 +2075,39 @@ uint8 | syspress | system pressure | uint8 | bar | false | DEVICE_DATA | 11 | 1 | 1/10 | | boiltemp | actual boiler temperature | uint16 | C | false | DEVICE_DATA | 12 | 1 | 1/10 | | headertemp | low loss header | uint16 | C | false | DEVICE_DATA | 13 | 1 | 1/10 | -| exhausttemp | exhaust temperature | uint16 | C | false | DEVICE_DATA | 253 | 1 | 1/10 | -| burngas | gas | boolean | | false | DEVICE_DATA | 254 | 1 | 1 | -| burngas2 | gas stage 2 | boolean | | false | DEVICE_DATA | 255 | 1 | 1 | -| flamecurr | flame current | uint16 | µA | false | DEVICE_DATA | 256 | 1 | 1/10 | -| fanwork | fan | boolean | | false | DEVICE_DATA | 257 | 1 | 1 | -| ignwork | ignition | boolean | | false | DEVICE_DATA | 258 | 1 | 1 | -| oilpreheat | oil preheating | boolean | | false | DEVICE_DATA | 259 | 1 | 1 | +| exhausttemp | exhaust temperature | uint16 | C | false | DEVICE_DATA | 254 | 1 | 1/10 | +| burngas | gas | boolean | | false | DEVICE_DATA | 255 | 1 | 1 | +| burngas2 | gas stage 2 | boolean | | false | DEVICE_DATA | 256 | 1 | 1 | +| flamecurr | flame current | uint16 | µA | false | DEVICE_DATA | 257 | 1 | 1/10 | +| fanwork | fan | boolean | | false | DEVICE_DATA | 258 | 1 | 1 | +| ignwork | ignition | boolean | | false | DEVICE_DATA | 259 | 1 | 1 | +| oilpreheat | oil preheating | boolean | | false | DEVICE_DATA | 260 | 1 | 1 | uint8 -| burnminpower | burner min power | uint8 (>=0<=0) | % | true | DEVICE_DATA | 260 | 1 | 1 | +| burnminpower | burner min power | uint8 (>=0<=0) | % | true | DEVICE_DATA | 261 | 1 | 1 | uint8 -| burnmaxpower | burner max power | uint8 (>=0<=254) | % | true | DEVICE_DATA | 261 | 1 | 1 | +| burnmaxpower | burner max power | uint8 (>=0<=254) | % | true | DEVICE_DATA | 262 | 1 | 1 | uint8 -| burnminperiod | burner min period | uint8 (>=0<=120) | minutes | true | DEVICE_DATA | 262 | 1 | 1 | -| absburnpow | burner current power (absolute) | uint8 | % | false | DEVICE_DATA | 263 | 1 | 1 | -| heatblock | Heatblock temperature | uint16 | C | false | DEVICE_DATA | 264 | 1 | 1/10 | +| burnminperiod | burner min period | uint8 (>=0<=120) | minutes | true | DEVICE_DATA | 263 | 1 | 1 | +| absburnpow | burner current power (absolute) | uint8 | % | false | DEVICE_DATA | 264 | 1 | 1 | +| heatblock | Heatblock temperature | uint16 | C | false | DEVICE_DATA | 265 | 1 | 1/10 | int8 -| boilhyston | hysteresis on temperature | int8 (>=-20<=0) | C | true | DEVICE_DATA | 265 | 1 | 1 | +| boilhyston | hysteresis on temperature | int8 (>=-20<=0) | C | true | DEVICE_DATA | 266 | 1 | 1 | int8 -| boilhystoff | hysteresis off temperature | int8 (>=0<=20) | C | true | DEVICE_DATA | 266 | 1 | 1 | +| boilhystoff | hysteresis off temperature | int8 (>=0<=20) | C | true | DEVICE_DATA | 267 | 1 | 1 | int8 -| boil2hyston | hysteresis stage 2 on temperature | int8 (>=-20<=0) | C | true | DEVICE_DATA | 267 | 1 | 1 | +| boil2hyston | hysteresis stage 2 on temperature | int8 (>=-20<=0) | C | true | DEVICE_DATA | 268 | 1 | 1 | int8 -| boil2hystoff | hysteresis stage 2 off temperature | int8 (>=0<=20) | C | true | DEVICE_DATA | 268 | 1 | 1 | -| curveon | heatingcurve on | boolean | | true | DEVICE_DATA | 269 | 1 | 1 | +| boil2hystoff | hysteresis stage 2 off temperature | int8 (>=0<=20) | C | true | DEVICE_DATA | 269 | 1 | 1 | +| curveon | heatingcurve on | boolean | | true | DEVICE_DATA | 270 | 1 | 1 | uint8 -| curvebase | heatingcurve base | uint8 (>=20<=90) | C | true | DEVICE_DATA | 270 | 1 | 1 | +| curvebase | heatingcurve base | uint8 (>=20<=90) | C | true | DEVICE_DATA | 271 | 1 | 1 | uint8 -| curveend | heatingcurve end | uint8 (>=20<=90) | C | true | DEVICE_DATA | 271 | 1 | 1 | +| curveend | heatingcurve end | uint8 (>=20<=90) | C | true | DEVICE_DATA | 272 | 1 | 1 | uint8 -| summertemp | summer temperature | uint8 (>=0<=45) | C | true | DEVICE_DATA | 272 | 1 | 1 | -| nofrostmode | nofrost mode | boolean | | true | DEVICE_DATA | 273 | 1 | 1 | +| summertemp | summer temperature | uint8 (>=0<=45) | C | true | DEVICE_DATA | 273 | 1 | 1 | +| nofrostmode | nofrost mode | boolean | | true | DEVICE_DATA | 274 | 1 | 1 | uint8 -| nofrosttemp | nofrost temperature | uint8 (>=0<=10) | C | true | DEVICE_DATA | 274 | 1 | 1 | +| nofrosttemp | nofrost temperature | uint8 (>=0<=10) | C | true | DEVICE_DATA | 275 | 1 | 1 | | heatingactivated | heating activated | boolean | | true | DEVICE_DATA | 14 | 1 | 1 | uint8 | heatingtemp | heating temperature | uint8 (>=0<=90) | C | true | DEVICE_DATA | 15 | 1 | 1 | @@ -2130,20 +2142,21 @@ uint16 | emergencyops | emergency operation | boolean | | true | DEVICE_DATA | 78 | 1 | 1 | uint8 | emergencytemp | emergency temperature | uint8 (>=15<=70) | C | true | DEVICE_DATA | 79 | 1 | 1 | -| pc0flow | Flow PC0 | int16 | l/h | false | DEVICE_DATA | 80 | 1 | 1 | -| pc1flow | Flow PC1 | int16 | l/h | false | DEVICE_DATA | 81 | 1 | 1 | -| pc1on | PC1 | boolean | | false | DEVICE_DATA | 82 | 1 | 1 | -| pc1rate | PC1 rate | uint8 | % | false | DEVICE_DATA | 83 | 1 | 1 | +| pc0lpm | Flow PC0 | uint16 | l/min | false | DEVICE_DATA | 80 | 1 | 1/10 | +| pc0flow | Flow PC0 | uint16 | l/h | false | DEVICE_DATA | 81 | 1 | 1 | +| pc1flow | Flow PC1 | uint16 | l/h | false | DEVICE_DATA | 82 | 1 | 1 | +| pc1on | PC1 | boolean | | false | DEVICE_DATA | 83 | 1 | 1 | +| pc1rate | PC1 rate | uint8 | % | false | DEVICE_DATA | 84 | 1 | 1 | uint8 -| pumpkickhour | pump kick hour | uint8 (>=0<=23) | hours | true | DEVICE_DATA | 84 | 1 | 1 | -| pumpkickday | pump kick day | enum | | true | DEVICE_DATA | 85 | 1 | 1 | +| pumpkickhour | pump kick hour | uint8 (>=0<=23) | hours | true | DEVICE_DATA | 85 | 1 | 1 | +| pumpkickday | pump kick day | enum | | true | DEVICE_DATA | 86 | 1 | 1 | uint16 -| pumpkickdelay | pump kick delay | uint16 (>=0<=32767) | minutes | true | DEVICE_DATA | 86 | 1 | 1 | -| meterheat | meter heating | uint24 | kWh | false | DEVICE_DATA | 100 | 2 | 1/10 | +| pumpkickdelay | pump kick delay | uint16 (>=0<=32767) | minutes | true | DEVICE_DATA | 87 | 1 | 1 | +| meterheat | meter heating | uint24 | kWh | false | DEVICE_DATA | 101 | 2 | 1/10 | | dhw.meter | meter | uint24 | kWh | false | DHW | 2 | 2 | 1/10 | -| gasmeterheat | gas meter heating | uint24 | kWh | false | DEVICE_DATA | 275 | 2 | 1/10 | +| gasmeterheat | gas meter heating | uint24 | kWh | false | DEVICE_DATA | 276 | 2 | 1/10 | | dhw.gasmeter | gas meter | uint24 | kWh | false | DHW | 71 | 2 | 1/10 | -| nrgheat2 | energy heating 2 | uint24 | kWh | false | DEVICE_DATA | 277 | 2 | 1/10 | +| nrgheat2 | energy heating 2 | uint24 | kWh | false | DEVICE_DATA | 278 | 2 | 1/10 | | dhw.nrg2 | energy 2 | uint24 | kWh | false | DHW | 73 | 2 | 1/10 | | dhw.tapactivated | turn on/off | boolean | | true | DHW | 28 | 1 | 1 | | dhw.settemp | set temperature | uint8 | C | false | DHW | 29 | 1 | 1 | @@ -2197,10 +2210,10 @@ uint8 | dhw.starts | starts | uint24 | | false | DHW | 67 | 2 | 1 | | dhw.workm | active time | time | minutes | false | DHW | 69 | 2 | 1 | uint8 -| nompower | nominal Power | uint8 (>=0<=0) | kW | true | DEVICE_DATA | 279 | 1 | 1 | -| nrgtotal | total energy | uint24 | kWh | false | DEVICE_DATA | 88 | 2 | 1/100 | +| nompower | nominal Power | uint8 (>=0<=0) | kW | true | DEVICE_DATA | 280 | 1 | 1 | +| nrgtotal | total energy | uint24 | kWh | false | DEVICE_DATA | 89 | 2 | 1/100 | uint24 -| nrgheat | energy heating | uint24 (>=0<=10000000) | kWh | true | DEVICE_DATA | 90 | 2 | 1/100 | +| nrgheat | energy heating | uint24 (>=0<=10000000) | kWh | true | DEVICE_DATA | 91 | 2 | 1/100 | uint24 | dhw.nrg | energy | uint24 (>=0<=10000000) | kWh | true | DHW | 0 | 2 | 1/100 | @@ -2223,39 +2236,39 @@ uint8 | syspress | system pressure | uint8 | bar | false | DEVICE_DATA | 11 | 1 | 1/10 | | boiltemp | actual boiler temperature | uint16 | C | false | DEVICE_DATA | 12 | 1 | 1/10 | | headertemp | low loss header | uint16 | C | false | DEVICE_DATA | 13 | 1 | 1/10 | -| exhausttemp | exhaust temperature | uint16 | C | false | DEVICE_DATA | 253 | 1 | 1/10 | -| burngas | gas | boolean | | false | DEVICE_DATA | 254 | 1 | 1 | -| burngas2 | gas stage 2 | boolean | | false | DEVICE_DATA | 255 | 1 | 1 | -| flamecurr | flame current | uint16 | µA | false | DEVICE_DATA | 256 | 1 | 1/10 | -| fanwork | fan | boolean | | false | DEVICE_DATA | 257 | 1 | 1 | -| ignwork | ignition | boolean | | false | DEVICE_DATA | 258 | 1 | 1 | -| oilpreheat | oil preheating | boolean | | false | DEVICE_DATA | 259 | 1 | 1 | +| exhausttemp | exhaust temperature | uint16 | C | false | DEVICE_DATA | 254 | 1 | 1/10 | +| burngas | gas | boolean | | false | DEVICE_DATA | 255 | 1 | 1 | +| burngas2 | gas stage 2 | boolean | | false | DEVICE_DATA | 256 | 1 | 1 | +| flamecurr | flame current | uint16 | µA | false | DEVICE_DATA | 257 | 1 | 1/10 | +| fanwork | fan | boolean | | false | DEVICE_DATA | 258 | 1 | 1 | +| ignwork | ignition | boolean | | false | DEVICE_DATA | 259 | 1 | 1 | +| oilpreheat | oil preheating | boolean | | false | DEVICE_DATA | 260 | 1 | 1 | uint8 -| burnminpower | burner min power | uint8 (>=0<=0) | % | true | DEVICE_DATA | 260 | 1 | 1 | +| burnminpower | burner min power | uint8 (>=0<=0) | % | true | DEVICE_DATA | 261 | 1 | 1 | uint8 -| burnmaxpower | burner max power | uint8 (>=0<=254) | % | true | DEVICE_DATA | 261 | 1 | 1 | +| burnmaxpower | burner max power | uint8 (>=0<=254) | % | true | DEVICE_DATA | 262 | 1 | 1 | uint8 -| burnminperiod | burner min period | uint8 (>=0<=120) | minutes | true | DEVICE_DATA | 262 | 1 | 1 | -| absburnpow | burner current power (absolute) | uint8 | % | false | DEVICE_DATA | 263 | 1 | 1 | -| heatblock | Heatblock temperature | uint16 | C | false | DEVICE_DATA | 264 | 1 | 1/10 | +| burnminperiod | burner min period | uint8 (>=0<=120) | minutes | true | DEVICE_DATA | 263 | 1 | 1 | +| absburnpow | burner current power (absolute) | uint8 | % | false | DEVICE_DATA | 264 | 1 | 1 | +| heatblock | Heatblock temperature | uint16 | C | false | DEVICE_DATA | 265 | 1 | 1/10 | int8 -| boilhyston | hysteresis on temperature | int8 (>=-20<=0) | C | true | DEVICE_DATA | 265 | 1 | 1 | +| boilhyston | hysteresis on temperature | int8 (>=-20<=0) | C | true | DEVICE_DATA | 266 | 1 | 1 | int8 -| boilhystoff | hysteresis off temperature | int8 (>=0<=20) | C | true | DEVICE_DATA | 266 | 1 | 1 | +| boilhystoff | hysteresis off temperature | int8 (>=0<=20) | C | true | DEVICE_DATA | 267 | 1 | 1 | int8 -| boil2hyston | hysteresis stage 2 on temperature | int8 (>=-20<=0) | C | true | DEVICE_DATA | 267 | 1 | 1 | +| boil2hyston | hysteresis stage 2 on temperature | int8 (>=-20<=0) | C | true | DEVICE_DATA | 268 | 1 | 1 | int8 -| boil2hystoff | hysteresis stage 2 off temperature | int8 (>=0<=20) | C | true | DEVICE_DATA | 268 | 1 | 1 | -| curveon | heatingcurve on | boolean | | true | DEVICE_DATA | 269 | 1 | 1 | +| boil2hystoff | hysteresis stage 2 off temperature | int8 (>=0<=20) | C | true | DEVICE_DATA | 269 | 1 | 1 | +| curveon | heatingcurve on | boolean | | true | DEVICE_DATA | 270 | 1 | 1 | uint8 -| curvebase | heatingcurve base | uint8 (>=20<=90) | C | true | DEVICE_DATA | 270 | 1 | 1 | +| curvebase | heatingcurve base | uint8 (>=20<=90) | C | true | DEVICE_DATA | 271 | 1 | 1 | uint8 -| curveend | heatingcurve end | uint8 (>=20<=90) | C | true | DEVICE_DATA | 271 | 1 | 1 | +| curveend | heatingcurve end | uint8 (>=20<=90) | C | true | DEVICE_DATA | 272 | 1 | 1 | uint8 -| summertemp | summer temperature | uint8 (>=0<=45) | C | true | DEVICE_DATA | 272 | 1 | 1 | -| nofrostmode | nofrost mode | boolean | | true | DEVICE_DATA | 273 | 1 | 1 | +| summertemp | summer temperature | uint8 (>=0<=45) | C | true | DEVICE_DATA | 273 | 1 | 1 | +| nofrostmode | nofrost mode | boolean | | true | DEVICE_DATA | 274 | 1 | 1 | uint8 -| nofrosttemp | nofrost temperature | uint8 (>=0<=10) | C | true | DEVICE_DATA | 274 | 1 | 1 | +| nofrosttemp | nofrost temperature | uint8 (>=0<=10) | C | true | DEVICE_DATA | 275 | 1 | 1 | | heatingactivated | heating activated | boolean | | true | DEVICE_DATA | 14 | 1 | 1 | uint8 | heatingtemp | heating temperature | uint8 (>=0<=90) | C | true | DEVICE_DATA | 15 | 1 | 1 | @@ -2290,20 +2303,21 @@ uint16 | emergencyops | emergency operation | boolean | | true | DEVICE_DATA | 78 | 1 | 1 | uint8 | emergencytemp | emergency temperature | uint8 (>=15<=70) | C | true | DEVICE_DATA | 79 | 1 | 1 | -| pc0flow | Flow PC0 | int16 | l/h | false | DEVICE_DATA | 80 | 1 | 1 | -| pc1flow | Flow PC1 | int16 | l/h | false | DEVICE_DATA | 81 | 1 | 1 | -| pc1on | PC1 | boolean | | false | DEVICE_DATA | 82 | 1 | 1 | -| pc1rate | PC1 rate | uint8 | % | false | DEVICE_DATA | 83 | 1 | 1 | +| pc0lpm | Flow PC0 | uint16 | l/min | false | DEVICE_DATA | 80 | 1 | 1/10 | +| pc0flow | Flow PC0 | uint16 | l/h | false | DEVICE_DATA | 81 | 1 | 1 | +| pc1flow | Flow PC1 | uint16 | l/h | false | DEVICE_DATA | 82 | 1 | 1 | +| pc1on | PC1 | boolean | | false | DEVICE_DATA | 83 | 1 | 1 | +| pc1rate | PC1 rate | uint8 | % | false | DEVICE_DATA | 84 | 1 | 1 | uint8 -| pumpkickhour | pump kick hour | uint8 (>=0<=23) | hours | true | DEVICE_DATA | 84 | 1 | 1 | -| pumpkickday | pump kick day | enum | | true | DEVICE_DATA | 85 | 1 | 1 | +| pumpkickhour | pump kick hour | uint8 (>=0<=23) | hours | true | DEVICE_DATA | 85 | 1 | 1 | +| pumpkickday | pump kick day | enum | | true | DEVICE_DATA | 86 | 1 | 1 | uint16 -| pumpkickdelay | pump kick delay | uint16 (>=0<=32767) | minutes | true | DEVICE_DATA | 86 | 1 | 1 | -| meterheat | meter heating | uint24 | kWh | false | DEVICE_DATA | 100 | 2 | 1/10 | +| pumpkickdelay | pump kick delay | uint16 (>=0<=32767) | minutes | true | DEVICE_DATA | 87 | 1 | 1 | +| meterheat | meter heating | uint24 | kWh | false | DEVICE_DATA | 101 | 2 | 1/10 | | dhw.meter | meter | uint24 | kWh | false | DHW | 2 | 2 | 1/10 | -| gasmeterheat | gas meter heating | uint24 | kWh | false | DEVICE_DATA | 275 | 2 | 1/10 | +| gasmeterheat | gas meter heating | uint24 | kWh | false | DEVICE_DATA | 276 | 2 | 1/10 | | dhw.gasmeter | gas meter | uint24 | kWh | false | DHW | 71 | 2 | 1/10 | -| nrgheat2 | energy heating 2 | uint24 | kWh | false | DEVICE_DATA | 277 | 2 | 1/10 | +| nrgheat2 | energy heating 2 | uint24 | kWh | false | DEVICE_DATA | 278 | 2 | 1/10 | | dhw.nrg2 | energy 2 | uint24 | kWh | false | DHW | 73 | 2 | 1/10 | | dhw.tapactivated | turn on/off | boolean | | true | DHW | 28 | 1 | 1 | | dhw.settemp | set temperature | uint8 | C | false | DHW | 29 | 1 | 1 | @@ -2357,10 +2371,10 @@ uint8 | dhw.starts | starts | uint24 | | false | DHW | 67 | 2 | 1 | | dhw.workm | active time | time | minutes | false | DHW | 69 | 2 | 1 | uint8 -| nompower | nominal Power | uint8 (>=0<=0) | kW | true | DEVICE_DATA | 279 | 1 | 1 | -| nrgtotal | total energy | uint24 | kWh | false | DEVICE_DATA | 88 | 2 | 1/100 | +| nompower | nominal Power | uint8 (>=0<=0) | kW | true | DEVICE_DATA | 280 | 1 | 1 | +| nrgtotal | total energy | uint24 | kWh | false | DEVICE_DATA | 89 | 2 | 1/100 | uint24 -| nrgheat | energy heating | uint24 (>=0<=10000000) | kWh | true | DEVICE_DATA | 90 | 2 | 1/100 | +| nrgheat | energy heating | uint24 (>=0<=10000000) | kWh | true | DEVICE_DATA | 91 | 2 | 1/100 | uint24 | dhw.nrg | energy | uint24 (>=0<=10000000) | kWh | true | DHW | 0 | 2 | 1/100 | @@ -2383,39 +2397,39 @@ uint8 | syspress | system pressure | uint8 | bar | false | DEVICE_DATA | 11 | 1 | 1/10 | | boiltemp | actual boiler temperature | uint16 | C | false | DEVICE_DATA | 12 | 1 | 1/10 | | headertemp | low loss header | uint16 | C | false | DEVICE_DATA | 13 | 1 | 1/10 | -| exhausttemp | exhaust temperature | uint16 | C | false | DEVICE_DATA | 253 | 1 | 1/10 | -| burngas | gas | boolean | | false | DEVICE_DATA | 254 | 1 | 1 | -| burngas2 | gas stage 2 | boolean | | false | DEVICE_DATA | 255 | 1 | 1 | -| flamecurr | flame current | uint16 | µA | false | DEVICE_DATA | 256 | 1 | 1/10 | -| fanwork | fan | boolean | | false | DEVICE_DATA | 257 | 1 | 1 | -| ignwork | ignition | boolean | | false | DEVICE_DATA | 258 | 1 | 1 | -| oilpreheat | oil preheating | boolean | | false | DEVICE_DATA | 259 | 1 | 1 | +| exhausttemp | exhaust temperature | uint16 | C | false | DEVICE_DATA | 254 | 1 | 1/10 | +| burngas | gas | boolean | | false | DEVICE_DATA | 255 | 1 | 1 | +| burngas2 | gas stage 2 | boolean | | false | DEVICE_DATA | 256 | 1 | 1 | +| flamecurr | flame current | uint16 | µA | false | DEVICE_DATA | 257 | 1 | 1/10 | +| fanwork | fan | boolean | | false | DEVICE_DATA | 258 | 1 | 1 | +| ignwork | ignition | boolean | | false | DEVICE_DATA | 259 | 1 | 1 | +| oilpreheat | oil preheating | boolean | | false | DEVICE_DATA | 260 | 1 | 1 | uint8 -| burnminpower | burner min power | uint8 (>=0<=0) | % | true | DEVICE_DATA | 260 | 1 | 1 | +| burnminpower | burner min power | uint8 (>=0<=0) | % | true | DEVICE_DATA | 261 | 1 | 1 | uint8 -| burnmaxpower | burner max power | uint8 (>=0<=254) | % | true | DEVICE_DATA | 261 | 1 | 1 | +| burnmaxpower | burner max power | uint8 (>=0<=254) | % | true | DEVICE_DATA | 262 | 1 | 1 | uint8 -| burnminperiod | burner min period | uint8 (>=0<=120) | minutes | true | DEVICE_DATA | 262 | 1 | 1 | -| absburnpow | burner current power (absolute) | uint8 | % | false | DEVICE_DATA | 263 | 1 | 1 | -| heatblock | Heatblock temperature | uint16 | C | false | DEVICE_DATA | 264 | 1 | 1/10 | +| burnminperiod | burner min period | uint8 (>=0<=120) | minutes | true | DEVICE_DATA | 263 | 1 | 1 | +| absburnpow | burner current power (absolute) | uint8 | % | false | DEVICE_DATA | 264 | 1 | 1 | +| heatblock | Heatblock temperature | uint16 | C | false | DEVICE_DATA | 265 | 1 | 1/10 | int8 -| boilhyston | hysteresis on temperature | int8 (>=-20<=0) | C | true | DEVICE_DATA | 265 | 1 | 1 | +| boilhyston | hysteresis on temperature | int8 (>=-20<=0) | C | true | DEVICE_DATA | 266 | 1 | 1 | int8 -| boilhystoff | hysteresis off temperature | int8 (>=0<=20) | C | true | DEVICE_DATA | 266 | 1 | 1 | +| boilhystoff | hysteresis off temperature | int8 (>=0<=20) | C | true | DEVICE_DATA | 267 | 1 | 1 | int8 -| boil2hyston | hysteresis stage 2 on temperature | int8 (>=-20<=0) | C | true | DEVICE_DATA | 267 | 1 | 1 | +| boil2hyston | hysteresis stage 2 on temperature | int8 (>=-20<=0) | C | true | DEVICE_DATA | 268 | 1 | 1 | int8 -| boil2hystoff | hysteresis stage 2 off temperature | int8 (>=0<=20) | C | true | DEVICE_DATA | 268 | 1 | 1 | -| curveon | heatingcurve on | boolean | | true | DEVICE_DATA | 269 | 1 | 1 | +| boil2hystoff | hysteresis stage 2 off temperature | int8 (>=0<=20) | C | true | DEVICE_DATA | 269 | 1 | 1 | +| curveon | heatingcurve on | boolean | | true | DEVICE_DATA | 270 | 1 | 1 | uint8 -| curvebase | heatingcurve base | uint8 (>=20<=90) | C | true | DEVICE_DATA | 270 | 1 | 1 | +| curvebase | heatingcurve base | uint8 (>=20<=90) | C | true | DEVICE_DATA | 271 | 1 | 1 | uint8 -| curveend | heatingcurve end | uint8 (>=20<=90) | C | true | DEVICE_DATA | 271 | 1 | 1 | +| curveend | heatingcurve end | uint8 (>=20<=90) | C | true | DEVICE_DATA | 272 | 1 | 1 | uint8 -| summertemp | summer temperature | uint8 (>=0<=45) | C | true | DEVICE_DATA | 272 | 1 | 1 | -| nofrostmode | nofrost mode | boolean | | true | DEVICE_DATA | 273 | 1 | 1 | +| summertemp | summer temperature | uint8 (>=0<=45) | C | true | DEVICE_DATA | 273 | 1 | 1 | +| nofrostmode | nofrost mode | boolean | | true | DEVICE_DATA | 274 | 1 | 1 | uint8 -| nofrosttemp | nofrost temperature | uint8 (>=0<=10) | C | true | DEVICE_DATA | 274 | 1 | 1 | +| nofrosttemp | nofrost temperature | uint8 (>=0<=10) | C | true | DEVICE_DATA | 275 | 1 | 1 | | heatingactivated | heating activated | boolean | | true | DEVICE_DATA | 14 | 1 | 1 | uint8 | heatingtemp | heating temperature | uint8 (>=0<=90) | C | true | DEVICE_DATA | 15 | 1 | 1 | @@ -2450,20 +2464,21 @@ uint16 | emergencyops | emergency operation | boolean | | true | DEVICE_DATA | 78 | 1 | 1 | uint8 | emergencytemp | emergency temperature | uint8 (>=15<=70) | C | true | DEVICE_DATA | 79 | 1 | 1 | -| pc0flow | Flow PC0 | int16 | l/h | false | DEVICE_DATA | 80 | 1 | 1 | -| pc1flow | Flow PC1 | int16 | l/h | false | DEVICE_DATA | 81 | 1 | 1 | -| pc1on | PC1 | boolean | | false | DEVICE_DATA | 82 | 1 | 1 | -| pc1rate | PC1 rate | uint8 | % | false | DEVICE_DATA | 83 | 1 | 1 | +| pc0lpm | Flow PC0 | uint16 | l/min | false | DEVICE_DATA | 80 | 1 | 1/10 | +| pc0flow | Flow PC0 | uint16 | l/h | false | DEVICE_DATA | 81 | 1 | 1 | +| pc1flow | Flow PC1 | uint16 | l/h | false | DEVICE_DATA | 82 | 1 | 1 | +| pc1on | PC1 | boolean | | false | DEVICE_DATA | 83 | 1 | 1 | +| pc1rate | PC1 rate | uint8 | % | false | DEVICE_DATA | 84 | 1 | 1 | uint8 -| pumpkickhour | pump kick hour | uint8 (>=0<=23) | hours | true | DEVICE_DATA | 84 | 1 | 1 | -| pumpkickday | pump kick day | enum | | true | DEVICE_DATA | 85 | 1 | 1 | +| pumpkickhour | pump kick hour | uint8 (>=0<=23) | hours | true | DEVICE_DATA | 85 | 1 | 1 | +| pumpkickday | pump kick day | enum | | true | DEVICE_DATA | 86 | 1 | 1 | uint16 -| pumpkickdelay | pump kick delay | uint16 (>=0<=32767) | minutes | true | DEVICE_DATA | 86 | 1 | 1 | -| meterheat | meter heating | uint24 | kWh | false | DEVICE_DATA | 100 | 2 | 1/10 | +| pumpkickdelay | pump kick delay | uint16 (>=0<=32767) | minutes | true | DEVICE_DATA | 87 | 1 | 1 | +| meterheat | meter heating | uint24 | kWh | false | DEVICE_DATA | 101 | 2 | 1/10 | | dhw.meter | meter | uint24 | kWh | false | DHW | 2 | 2 | 1/10 | -| gasmeterheat | gas meter heating | uint24 | kWh | false | DEVICE_DATA | 275 | 2 | 1/10 | +| gasmeterheat | gas meter heating | uint24 | kWh | false | DEVICE_DATA | 276 | 2 | 1/10 | | dhw.gasmeter | gas meter | uint24 | kWh | false | DHW | 71 | 2 | 1/10 | -| nrgheat2 | energy heating 2 | uint24 | kWh | false | DEVICE_DATA | 277 | 2 | 1/10 | +| nrgheat2 | energy heating 2 | uint24 | kWh | false | DEVICE_DATA | 278 | 2 | 1/10 | | dhw.nrg2 | energy 2 | uint24 | kWh | false | DHW | 73 | 2 | 1/10 | | dhw.tapactivated | turn on/off | boolean | | true | DHW | 28 | 1 | 1 | | dhw.settemp | set temperature | uint8 | C | false | DHW | 29 | 1 | 1 | @@ -2517,10 +2532,10 @@ uint8 | dhw.starts | starts | uint24 | | false | DHW | 67 | 2 | 1 | | dhw.workm | active time | time | minutes | false | DHW | 69 | 2 | 1 | uint8 -| nompower | nominal Power | uint8 (>=0<=0) | kW | true | DEVICE_DATA | 279 | 1 | 1 | -| nrgtotal | total energy | uint24 | kWh | false | DEVICE_DATA | 88 | 2 | 1/100 | +| nompower | nominal Power | uint8 (>=0<=0) | kW | true | DEVICE_DATA | 280 | 1 | 1 | +| nrgtotal | total energy | uint24 | kWh | false | DEVICE_DATA | 89 | 2 | 1/100 | uint24 -| nrgheat | energy heating | uint24 (>=0<=10000000) | kWh | true | DEVICE_DATA | 90 | 2 | 1/100 | +| nrgheat | energy heating | uint24 (>=0<=10000000) | kWh | true | DEVICE_DATA | 91 | 2 | 1/100 | uint24 | dhw.nrg | energy | uint24 (>=0<=10000000) | kWh | true | DHW | 0 | 2 | 1/100 | @@ -2543,39 +2558,39 @@ uint8 | syspress | system pressure | uint8 | bar | false | DEVICE_DATA | 11 | 1 | 1/10 | | boiltemp | actual boiler temperature | uint16 | C | false | DEVICE_DATA | 12 | 1 | 1/10 | | headertemp | low loss header | uint16 | C | false | DEVICE_DATA | 13 | 1 | 1/10 | -| exhausttemp | exhaust temperature | uint16 | C | false | DEVICE_DATA | 253 | 1 | 1/10 | -| burngas | gas | boolean | | false | DEVICE_DATA | 254 | 1 | 1 | -| burngas2 | gas stage 2 | boolean | | false | DEVICE_DATA | 255 | 1 | 1 | -| flamecurr | flame current | uint16 | µA | false | DEVICE_DATA | 256 | 1 | 1/10 | -| fanwork | fan | boolean | | false | DEVICE_DATA | 257 | 1 | 1 | -| ignwork | ignition | boolean | | false | DEVICE_DATA | 258 | 1 | 1 | -| oilpreheat | oil preheating | boolean | | false | DEVICE_DATA | 259 | 1 | 1 | +| exhausttemp | exhaust temperature | uint16 | C | false | DEVICE_DATA | 254 | 1 | 1/10 | +| burngas | gas | boolean | | false | DEVICE_DATA | 255 | 1 | 1 | +| burngas2 | gas stage 2 | boolean | | false | DEVICE_DATA | 256 | 1 | 1 | +| flamecurr | flame current | uint16 | µA | false | DEVICE_DATA | 257 | 1 | 1/10 | +| fanwork | fan | boolean | | false | DEVICE_DATA | 258 | 1 | 1 | +| ignwork | ignition | boolean | | false | DEVICE_DATA | 259 | 1 | 1 | +| oilpreheat | oil preheating | boolean | | false | DEVICE_DATA | 260 | 1 | 1 | uint8 -| burnminpower | burner min power | uint8 (>=0<=0) | % | true | DEVICE_DATA | 260 | 1 | 1 | +| burnminpower | burner min power | uint8 (>=0<=0) | % | true | DEVICE_DATA | 261 | 1 | 1 | uint8 -| burnmaxpower | burner max power | uint8 (>=0<=254) | % | true | DEVICE_DATA | 261 | 1 | 1 | +| burnmaxpower | burner max power | uint8 (>=0<=254) | % | true | DEVICE_DATA | 262 | 1 | 1 | uint8 -| burnminperiod | burner min period | uint8 (>=0<=120) | minutes | true | DEVICE_DATA | 262 | 1 | 1 | -| absburnpow | burner current power (absolute) | uint8 | % | false | DEVICE_DATA | 263 | 1 | 1 | -| heatblock | Heatblock temperature | uint16 | C | false | DEVICE_DATA | 264 | 1 | 1/10 | +| burnminperiod | burner min period | uint8 (>=0<=120) | minutes | true | DEVICE_DATA | 263 | 1 | 1 | +| absburnpow | burner current power (absolute) | uint8 | % | false | DEVICE_DATA | 264 | 1 | 1 | +| heatblock | Heatblock temperature | uint16 | C | false | DEVICE_DATA | 265 | 1 | 1/10 | int8 -| boilhyston | hysteresis on temperature | int8 (>=-20<=0) | C | true | DEVICE_DATA | 265 | 1 | 1 | +| boilhyston | hysteresis on temperature | int8 (>=-20<=0) | C | true | DEVICE_DATA | 266 | 1 | 1 | int8 -| boilhystoff | hysteresis off temperature | int8 (>=0<=20) | C | true | DEVICE_DATA | 266 | 1 | 1 | +| boilhystoff | hysteresis off temperature | int8 (>=0<=20) | C | true | DEVICE_DATA | 267 | 1 | 1 | int8 -| boil2hyston | hysteresis stage 2 on temperature | int8 (>=-20<=0) | C | true | DEVICE_DATA | 267 | 1 | 1 | +| boil2hyston | hysteresis stage 2 on temperature | int8 (>=-20<=0) | C | true | DEVICE_DATA | 268 | 1 | 1 | int8 -| boil2hystoff | hysteresis stage 2 off temperature | int8 (>=0<=20) | C | true | DEVICE_DATA | 268 | 1 | 1 | -| curveon | heatingcurve on | boolean | | true | DEVICE_DATA | 269 | 1 | 1 | +| boil2hystoff | hysteresis stage 2 off temperature | int8 (>=0<=20) | C | true | DEVICE_DATA | 269 | 1 | 1 | +| curveon | heatingcurve on | boolean | | true | DEVICE_DATA | 270 | 1 | 1 | uint8 -| curvebase | heatingcurve base | uint8 (>=20<=90) | C | true | DEVICE_DATA | 270 | 1 | 1 | +| curvebase | heatingcurve base | uint8 (>=20<=90) | C | true | DEVICE_DATA | 271 | 1 | 1 | uint8 -| curveend | heatingcurve end | uint8 (>=20<=90) | C | true | DEVICE_DATA | 271 | 1 | 1 | +| curveend | heatingcurve end | uint8 (>=20<=90) | C | true | DEVICE_DATA | 272 | 1 | 1 | uint8 -| summertemp | summer temperature | uint8 (>=0<=45) | C | true | DEVICE_DATA | 272 | 1 | 1 | -| nofrostmode | nofrost mode | boolean | | true | DEVICE_DATA | 273 | 1 | 1 | +| summertemp | summer temperature | uint8 (>=0<=45) | C | true | DEVICE_DATA | 273 | 1 | 1 | +| nofrostmode | nofrost mode | boolean | | true | DEVICE_DATA | 274 | 1 | 1 | uint8 -| nofrosttemp | nofrost temperature | uint8 (>=0<=10) | C | true | DEVICE_DATA | 274 | 1 | 1 | +| nofrosttemp | nofrost temperature | uint8 (>=0<=10) | C | true | DEVICE_DATA | 275 | 1 | 1 | | heatingactivated | heating activated | boolean | | true | DEVICE_DATA | 14 | 1 | 1 | uint8 | heatingtemp | heating temperature | uint8 (>=0<=90) | C | true | DEVICE_DATA | 15 | 1 | 1 | @@ -2610,20 +2625,21 @@ uint16 | emergencyops | emergency operation | boolean | | true | DEVICE_DATA | 78 | 1 | 1 | uint8 | emergencytemp | emergency temperature | uint8 (>=15<=70) | C | true | DEVICE_DATA | 79 | 1 | 1 | -| pc0flow | Flow PC0 | int16 | l/h | false | DEVICE_DATA | 80 | 1 | 1 | -| pc1flow | Flow PC1 | int16 | l/h | false | DEVICE_DATA | 81 | 1 | 1 | -| pc1on | PC1 | boolean | | false | DEVICE_DATA | 82 | 1 | 1 | -| pc1rate | PC1 rate | uint8 | % | false | DEVICE_DATA | 83 | 1 | 1 | +| pc0lpm | Flow PC0 | uint16 | l/min | false | DEVICE_DATA | 80 | 1 | 1/10 | +| pc0flow | Flow PC0 | uint16 | l/h | false | DEVICE_DATA | 81 | 1 | 1 | +| pc1flow | Flow PC1 | uint16 | l/h | false | DEVICE_DATA | 82 | 1 | 1 | +| pc1on | PC1 | boolean | | false | DEVICE_DATA | 83 | 1 | 1 | +| pc1rate | PC1 rate | uint8 | % | false | DEVICE_DATA | 84 | 1 | 1 | uint8 -| pumpkickhour | pump kick hour | uint8 (>=0<=23) | hours | true | DEVICE_DATA | 84 | 1 | 1 | -| pumpkickday | pump kick day | enum | | true | DEVICE_DATA | 85 | 1 | 1 | +| pumpkickhour | pump kick hour | uint8 (>=0<=23) | hours | true | DEVICE_DATA | 85 | 1 | 1 | +| pumpkickday | pump kick day | enum | | true | DEVICE_DATA | 86 | 1 | 1 | uint16 -| pumpkickdelay | pump kick delay | uint16 (>=0<=32767) | minutes | true | DEVICE_DATA | 86 | 1 | 1 | -| meterheat | meter heating | uint24 | kWh | false | DEVICE_DATA | 100 | 2 | 1/10 | +| pumpkickdelay | pump kick delay | uint16 (>=0<=32767) | minutes | true | DEVICE_DATA | 87 | 1 | 1 | +| meterheat | meter heating | uint24 | kWh | false | DEVICE_DATA | 101 | 2 | 1/10 | | dhw.meter | meter | uint24 | kWh | false | DHW | 2 | 2 | 1/10 | -| gasmeterheat | gas meter heating | uint24 | kWh | false | DEVICE_DATA | 275 | 2 | 1/10 | +| gasmeterheat | gas meter heating | uint24 | kWh | false | DEVICE_DATA | 276 | 2 | 1/10 | | dhw.gasmeter | gas meter | uint24 | kWh | false | DHW | 71 | 2 | 1/10 | -| nrgheat2 | energy heating 2 | uint24 | kWh | false | DEVICE_DATA | 277 | 2 | 1/10 | +| nrgheat2 | energy heating 2 | uint24 | kWh | false | DEVICE_DATA | 278 | 2 | 1/10 | | dhw.nrg2 | energy 2 | uint24 | kWh | false | DHW | 73 | 2 | 1/10 | | dhw.tapactivated | turn on/off | boolean | | true | DHW | 28 | 1 | 1 | | dhw.settemp | set temperature | uint8 | C | false | DHW | 29 | 1 | 1 | @@ -2677,10 +2693,10 @@ uint8 | dhw.starts | starts | uint24 | | false | DHW | 67 | 2 | 1 | | dhw.workm | active time | time | minutes | false | DHW | 69 | 2 | 1 | uint8 -| nompower | nominal Power | uint8 (>=0<=0) | kW | true | DEVICE_DATA | 279 | 1 | 1 | -| nrgtotal | total energy | uint24 | kWh | false | DEVICE_DATA | 88 | 2 | 1/100 | +| nompower | nominal Power | uint8 (>=0<=0) | kW | true | DEVICE_DATA | 280 | 1 | 1 | +| nrgtotal | total energy | uint24 | kWh | false | DEVICE_DATA | 89 | 2 | 1/100 | uint24 -| nrgheat | energy heating | uint24 (>=0<=10000000) | kWh | true | DEVICE_DATA | 90 | 2 | 1/100 | +| nrgheat | energy heating | uint24 (>=0<=10000000) | kWh | true | DEVICE_DATA | 91 | 2 | 1/100 | uint24 | dhw.nrg | energy | uint24 (>=0<=10000000) | kWh | true | DHW | 0 | 2 | 1/100 | @@ -2703,39 +2719,39 @@ uint8 | syspress | system pressure | uint8 | bar | false | DEVICE_DATA | 11 | 1 | 1/10 | | boiltemp | actual boiler temperature | uint16 | C | false | DEVICE_DATA | 12 | 1 | 1/10 | | headertemp | low loss header | uint16 | C | false | DEVICE_DATA | 13 | 1 | 1/10 | -| exhausttemp | exhaust temperature | uint16 | C | false | DEVICE_DATA | 253 | 1 | 1/10 | -| burngas | gas | boolean | | false | DEVICE_DATA | 254 | 1 | 1 | -| burngas2 | gas stage 2 | boolean | | false | DEVICE_DATA | 255 | 1 | 1 | -| flamecurr | flame current | uint16 | µA | false | DEVICE_DATA | 256 | 1 | 1/10 | -| fanwork | fan | boolean | | false | DEVICE_DATA | 257 | 1 | 1 | -| ignwork | ignition | boolean | | false | DEVICE_DATA | 258 | 1 | 1 | -| oilpreheat | oil preheating | boolean | | false | DEVICE_DATA | 259 | 1 | 1 | +| exhausttemp | exhaust temperature | uint16 | C | false | DEVICE_DATA | 254 | 1 | 1/10 | +| burngas | gas | boolean | | false | DEVICE_DATA | 255 | 1 | 1 | +| burngas2 | gas stage 2 | boolean | | false | DEVICE_DATA | 256 | 1 | 1 | +| flamecurr | flame current | uint16 | µA | false | DEVICE_DATA | 257 | 1 | 1/10 | +| fanwork | fan | boolean | | false | DEVICE_DATA | 258 | 1 | 1 | +| ignwork | ignition | boolean | | false | DEVICE_DATA | 259 | 1 | 1 | +| oilpreheat | oil preheating | boolean | | false | DEVICE_DATA | 260 | 1 | 1 | uint8 -| burnminpower | burner min power | uint8 (>=0<=0) | % | true | DEVICE_DATA | 260 | 1 | 1 | +| burnminpower | burner min power | uint8 (>=0<=0) | % | true | DEVICE_DATA | 261 | 1 | 1 | uint8 -| burnmaxpower | burner max power | uint8 (>=0<=254) | % | true | DEVICE_DATA | 261 | 1 | 1 | +| burnmaxpower | burner max power | uint8 (>=0<=254) | % | true | DEVICE_DATA | 262 | 1 | 1 | uint8 -| burnminperiod | burner min period | uint8 (>=0<=120) | minutes | true | DEVICE_DATA | 262 | 1 | 1 | -| absburnpow | burner current power (absolute) | uint8 | % | false | DEVICE_DATA | 263 | 1 | 1 | -| heatblock | Heatblock temperature | uint16 | C | false | DEVICE_DATA | 264 | 1 | 1/10 | +| burnminperiod | burner min period | uint8 (>=0<=120) | minutes | true | DEVICE_DATA | 263 | 1 | 1 | +| absburnpow | burner current power (absolute) | uint8 | % | false | DEVICE_DATA | 264 | 1 | 1 | +| heatblock | Heatblock temperature | uint16 | C | false | DEVICE_DATA | 265 | 1 | 1/10 | int8 -| boilhyston | hysteresis on temperature | int8 (>=-20<=0) | C | true | DEVICE_DATA | 265 | 1 | 1 | +| boilhyston | hysteresis on temperature | int8 (>=-20<=0) | C | true | DEVICE_DATA | 266 | 1 | 1 | int8 -| boilhystoff | hysteresis off temperature | int8 (>=0<=20) | C | true | DEVICE_DATA | 266 | 1 | 1 | +| boilhystoff | hysteresis off temperature | int8 (>=0<=20) | C | true | DEVICE_DATA | 267 | 1 | 1 | int8 -| boil2hyston | hysteresis stage 2 on temperature | int8 (>=-20<=0) | C | true | DEVICE_DATA | 267 | 1 | 1 | +| boil2hyston | hysteresis stage 2 on temperature | int8 (>=-20<=0) | C | true | DEVICE_DATA | 268 | 1 | 1 | int8 -| boil2hystoff | hysteresis stage 2 off temperature | int8 (>=0<=20) | C | true | DEVICE_DATA | 268 | 1 | 1 | -| curveon | heatingcurve on | boolean | | true | DEVICE_DATA | 269 | 1 | 1 | +| boil2hystoff | hysteresis stage 2 off temperature | int8 (>=0<=20) | C | true | DEVICE_DATA | 269 | 1 | 1 | +| curveon | heatingcurve on | boolean | | true | DEVICE_DATA | 270 | 1 | 1 | uint8 -| curvebase | heatingcurve base | uint8 (>=20<=90) | C | true | DEVICE_DATA | 270 | 1 | 1 | +| curvebase | heatingcurve base | uint8 (>=20<=90) | C | true | DEVICE_DATA | 271 | 1 | 1 | uint8 -| curveend | heatingcurve end | uint8 (>=20<=90) | C | true | DEVICE_DATA | 271 | 1 | 1 | +| curveend | heatingcurve end | uint8 (>=20<=90) | C | true | DEVICE_DATA | 272 | 1 | 1 | uint8 -| summertemp | summer temperature | uint8 (>=0<=45) | C | true | DEVICE_DATA | 272 | 1 | 1 | -| nofrostmode | nofrost mode | boolean | | true | DEVICE_DATA | 273 | 1 | 1 | +| summertemp | summer temperature | uint8 (>=0<=45) | C | true | DEVICE_DATA | 273 | 1 | 1 | +| nofrostmode | nofrost mode | boolean | | true | DEVICE_DATA | 274 | 1 | 1 | uint8 -| nofrosttemp | nofrost temperature | uint8 (>=0<=10) | C | true | DEVICE_DATA | 274 | 1 | 1 | +| nofrosttemp | nofrost temperature | uint8 (>=0<=10) | C | true | DEVICE_DATA | 275 | 1 | 1 | | heatingactivated | heating activated | boolean | | true | DEVICE_DATA | 14 | 1 | 1 | uint8 | heatingtemp | heating temperature | uint8 (>=0<=90) | C | true | DEVICE_DATA | 15 | 1 | 1 | @@ -2770,20 +2786,21 @@ uint16 | emergencyops | emergency operation | boolean | | true | DEVICE_DATA | 78 | 1 | 1 | uint8 | emergencytemp | emergency temperature | uint8 (>=15<=70) | C | true | DEVICE_DATA | 79 | 1 | 1 | -| pc0flow | Flow PC0 | int16 | l/h | false | DEVICE_DATA | 80 | 1 | 1 | -| pc1flow | Flow PC1 | int16 | l/h | false | DEVICE_DATA | 81 | 1 | 1 | -| pc1on | PC1 | boolean | | false | DEVICE_DATA | 82 | 1 | 1 | -| pc1rate | PC1 rate | uint8 | % | false | DEVICE_DATA | 83 | 1 | 1 | +| pc0lpm | Flow PC0 | uint16 | l/min | false | DEVICE_DATA | 80 | 1 | 1/10 | +| pc0flow | Flow PC0 | uint16 | l/h | false | DEVICE_DATA | 81 | 1 | 1 | +| pc1flow | Flow PC1 | uint16 | l/h | false | DEVICE_DATA | 82 | 1 | 1 | +| pc1on | PC1 | boolean | | false | DEVICE_DATA | 83 | 1 | 1 | +| pc1rate | PC1 rate | uint8 | % | false | DEVICE_DATA | 84 | 1 | 1 | uint8 -| pumpkickhour | pump kick hour | uint8 (>=0<=23) | hours | true | DEVICE_DATA | 84 | 1 | 1 | -| pumpkickday | pump kick day | enum | | true | DEVICE_DATA | 85 | 1 | 1 | +| pumpkickhour | pump kick hour | uint8 (>=0<=23) | hours | true | DEVICE_DATA | 85 | 1 | 1 | +| pumpkickday | pump kick day | enum | | true | DEVICE_DATA | 86 | 1 | 1 | uint16 -| pumpkickdelay | pump kick delay | uint16 (>=0<=32767) | minutes | true | DEVICE_DATA | 86 | 1 | 1 | -| meterheat | meter heating | uint24 | kWh | false | DEVICE_DATA | 100 | 2 | 1/10 | +| pumpkickdelay | pump kick delay | uint16 (>=0<=32767) | minutes | true | DEVICE_DATA | 87 | 1 | 1 | +| meterheat | meter heating | uint24 | kWh | false | DEVICE_DATA | 101 | 2 | 1/10 | | dhw.meter | meter | uint24 | kWh | false | DHW | 2 | 2 | 1/10 | -| gasmeterheat | gas meter heating | uint24 | kWh | false | DEVICE_DATA | 275 | 2 | 1/10 | +| gasmeterheat | gas meter heating | uint24 | kWh | false | DEVICE_DATA | 276 | 2 | 1/10 | | dhw.gasmeter | gas meter | uint24 | kWh | false | DHW | 71 | 2 | 1/10 | -| nrgheat2 | energy heating 2 | uint24 | kWh | false | DEVICE_DATA | 277 | 2 | 1/10 | +| nrgheat2 | energy heating 2 | uint24 | kWh | false | DEVICE_DATA | 278 | 2 | 1/10 | | dhw.nrg2 | energy 2 | uint24 | kWh | false | DHW | 73 | 2 | 1/10 | | dhw.tapactivated | turn on/off | boolean | | true | DHW | 28 | 1 | 1 | | dhw.settemp | set temperature | uint8 | C | false | DHW | 29 | 1 | 1 | @@ -2837,10 +2854,10 @@ uint8 | dhw.starts | starts | uint24 | | false | DHW | 67 | 2 | 1 | | dhw.workm | active time | time | minutes | false | DHW | 69 | 2 | 1 | uint8 -| nompower | nominal Power | uint8 (>=0<=0) | kW | true | DEVICE_DATA | 279 | 1 | 1 | -| nrgtotal | total energy | uint24 | kWh | false | DEVICE_DATA | 88 | 2 | 1/100 | +| nompower | nominal Power | uint8 (>=0<=0) | kW | true | DEVICE_DATA | 280 | 1 | 1 | +| nrgtotal | total energy | uint24 | kWh | false | DEVICE_DATA | 89 | 2 | 1/100 | uint24 -| nrgheat | energy heating | uint24 (>=0<=10000000) | kWh | true | DEVICE_DATA | 90 | 2 | 1/100 | +| nrgheat | energy heating | uint24 (>=0<=10000000) | kWh | true | DEVICE_DATA | 91 | 2 | 1/100 | uint24 | dhw.nrg | energy | uint24 (>=0<=10000000) | kWh | true | DHW | 0 | 2 | 1/100 | @@ -2863,39 +2880,39 @@ uint8 | syspress | system pressure | uint8 | bar | false | DEVICE_DATA | 11 | 1 | 1/10 | | boiltemp | actual boiler temperature | uint16 | C | false | DEVICE_DATA | 12 | 1 | 1/10 | | headertemp | low loss header | uint16 | C | false | DEVICE_DATA | 13 | 1 | 1/10 | -| exhausttemp | exhaust temperature | uint16 | C | false | DEVICE_DATA | 253 | 1 | 1/10 | -| burngas | gas | boolean | | false | DEVICE_DATA | 254 | 1 | 1 | -| burngas2 | gas stage 2 | boolean | | false | DEVICE_DATA | 255 | 1 | 1 | -| flamecurr | flame current | uint16 | µA | false | DEVICE_DATA | 256 | 1 | 1/10 | -| fanwork | fan | boolean | | false | DEVICE_DATA | 257 | 1 | 1 | -| ignwork | ignition | boolean | | false | DEVICE_DATA | 258 | 1 | 1 | -| oilpreheat | oil preheating | boolean | | false | DEVICE_DATA | 259 | 1 | 1 | +| exhausttemp | exhaust temperature | uint16 | C | false | DEVICE_DATA | 254 | 1 | 1/10 | +| burngas | gas | boolean | | false | DEVICE_DATA | 255 | 1 | 1 | +| burngas2 | gas stage 2 | boolean | | false | DEVICE_DATA | 256 | 1 | 1 | +| flamecurr | flame current | uint16 | µA | false | DEVICE_DATA | 257 | 1 | 1/10 | +| fanwork | fan | boolean | | false | DEVICE_DATA | 258 | 1 | 1 | +| ignwork | ignition | boolean | | false | DEVICE_DATA | 259 | 1 | 1 | +| oilpreheat | oil preheating | boolean | | false | DEVICE_DATA | 260 | 1 | 1 | uint8 -| burnminpower | burner min power | uint8 (>=0<=0) | % | true | DEVICE_DATA | 260 | 1 | 1 | +| burnminpower | burner min power | uint8 (>=0<=0) | % | true | DEVICE_DATA | 261 | 1 | 1 | uint8 -| burnmaxpower | burner max power | uint8 (>=0<=254) | % | true | DEVICE_DATA | 261 | 1 | 1 | +| burnmaxpower | burner max power | uint8 (>=0<=254) | % | true | DEVICE_DATA | 262 | 1 | 1 | uint8 -| burnminperiod | burner min period | uint8 (>=0<=120) | minutes | true | DEVICE_DATA | 262 | 1 | 1 | -| absburnpow | burner current power (absolute) | uint8 | % | false | DEVICE_DATA | 263 | 1 | 1 | -| heatblock | Heatblock temperature | uint16 | C | false | DEVICE_DATA | 264 | 1 | 1/10 | +| burnminperiod | burner min period | uint8 (>=0<=120) | minutes | true | DEVICE_DATA | 263 | 1 | 1 | +| absburnpow | burner current power (absolute) | uint8 | % | false | DEVICE_DATA | 264 | 1 | 1 | +| heatblock | Heatblock temperature | uint16 | C | false | DEVICE_DATA | 265 | 1 | 1/10 | int8 -| boilhyston | hysteresis on temperature | int8 (>=-20<=0) | C | true | DEVICE_DATA | 265 | 1 | 1 | +| boilhyston | hysteresis on temperature | int8 (>=-20<=0) | C | true | DEVICE_DATA | 266 | 1 | 1 | int8 -| boilhystoff | hysteresis off temperature | int8 (>=0<=20) | C | true | DEVICE_DATA | 266 | 1 | 1 | +| boilhystoff | hysteresis off temperature | int8 (>=0<=20) | C | true | DEVICE_DATA | 267 | 1 | 1 | int8 -| boil2hyston | hysteresis stage 2 on temperature | int8 (>=-20<=0) | C | true | DEVICE_DATA | 267 | 1 | 1 | +| boil2hyston | hysteresis stage 2 on temperature | int8 (>=-20<=0) | C | true | DEVICE_DATA | 268 | 1 | 1 | int8 -| boil2hystoff | hysteresis stage 2 off temperature | int8 (>=0<=20) | C | true | DEVICE_DATA | 268 | 1 | 1 | -| curveon | heatingcurve on | boolean | | true | DEVICE_DATA | 269 | 1 | 1 | +| boil2hystoff | hysteresis stage 2 off temperature | int8 (>=0<=20) | C | true | DEVICE_DATA | 269 | 1 | 1 | +| curveon | heatingcurve on | boolean | | true | DEVICE_DATA | 270 | 1 | 1 | uint8 -| curvebase | heatingcurve base | uint8 (>=20<=90) | C | true | DEVICE_DATA | 270 | 1 | 1 | +| curvebase | heatingcurve base | uint8 (>=20<=90) | C | true | DEVICE_DATA | 271 | 1 | 1 | uint8 -| curveend | heatingcurve end | uint8 (>=20<=90) | C | true | DEVICE_DATA | 271 | 1 | 1 | +| curveend | heatingcurve end | uint8 (>=20<=90) | C | true | DEVICE_DATA | 272 | 1 | 1 | uint8 -| summertemp | summer temperature | uint8 (>=0<=45) | C | true | DEVICE_DATA | 272 | 1 | 1 | -| nofrostmode | nofrost mode | boolean | | true | DEVICE_DATA | 273 | 1 | 1 | +| summertemp | summer temperature | uint8 (>=0<=45) | C | true | DEVICE_DATA | 273 | 1 | 1 | +| nofrostmode | nofrost mode | boolean | | true | DEVICE_DATA | 274 | 1 | 1 | uint8 -| nofrosttemp | nofrost temperature | uint8 (>=0<=10) | C | true | DEVICE_DATA | 274 | 1 | 1 | +| nofrosttemp | nofrost temperature | uint8 (>=0<=10) | C | true | DEVICE_DATA | 275 | 1 | 1 | | heatingactivated | heating activated | boolean | | true | DEVICE_DATA | 14 | 1 | 1 | uint8 | heatingtemp | heating temperature | uint8 (>=0<=90) | C | true | DEVICE_DATA | 15 | 1 | 1 | @@ -2930,20 +2947,21 @@ uint16 | emergencyops | emergency operation | boolean | | true | DEVICE_DATA | 78 | 1 | 1 | uint8 | emergencytemp | emergency temperature | uint8 (>=15<=70) | C | true | DEVICE_DATA | 79 | 1 | 1 | -| pc0flow | Flow PC0 | int16 | l/h | false | DEVICE_DATA | 80 | 1 | 1 | -| pc1flow | Flow PC1 | int16 | l/h | false | DEVICE_DATA | 81 | 1 | 1 | -| pc1on | PC1 | boolean | | false | DEVICE_DATA | 82 | 1 | 1 | -| pc1rate | PC1 rate | uint8 | % | false | DEVICE_DATA | 83 | 1 | 1 | +| pc0lpm | Flow PC0 | uint16 | l/min | false | DEVICE_DATA | 80 | 1 | 1/10 | +| pc0flow | Flow PC0 | uint16 | l/h | false | DEVICE_DATA | 81 | 1 | 1 | +| pc1flow | Flow PC1 | uint16 | l/h | false | DEVICE_DATA | 82 | 1 | 1 | +| pc1on | PC1 | boolean | | false | DEVICE_DATA | 83 | 1 | 1 | +| pc1rate | PC1 rate | uint8 | % | false | DEVICE_DATA | 84 | 1 | 1 | uint8 -| pumpkickhour | pump kick hour | uint8 (>=0<=23) | hours | true | DEVICE_DATA | 84 | 1 | 1 | -| pumpkickday | pump kick day | enum | | true | DEVICE_DATA | 85 | 1 | 1 | +| pumpkickhour | pump kick hour | uint8 (>=0<=23) | hours | true | DEVICE_DATA | 85 | 1 | 1 | +| pumpkickday | pump kick day | enum | | true | DEVICE_DATA | 86 | 1 | 1 | uint16 -| pumpkickdelay | pump kick delay | uint16 (>=0<=32767) | minutes | true | DEVICE_DATA | 86 | 1 | 1 | -| meterheat | meter heating | uint24 | kWh | false | DEVICE_DATA | 100 | 2 | 1/10 | +| pumpkickdelay | pump kick delay | uint16 (>=0<=32767) | minutes | true | DEVICE_DATA | 87 | 1 | 1 | +| meterheat | meter heating | uint24 | kWh | false | DEVICE_DATA | 101 | 2 | 1/10 | | dhw.meter | meter | uint24 | kWh | false | DHW | 2 | 2 | 1/10 | -| gasmeterheat | gas meter heating | uint24 | kWh | false | DEVICE_DATA | 275 | 2 | 1/10 | +| gasmeterheat | gas meter heating | uint24 | kWh | false | DEVICE_DATA | 276 | 2 | 1/10 | | dhw.gasmeter | gas meter | uint24 | kWh | false | DHW | 71 | 2 | 1/10 | -| nrgheat2 | energy heating 2 | uint24 | kWh | false | DEVICE_DATA | 277 | 2 | 1/10 | +| nrgheat2 | energy heating 2 | uint24 | kWh | false | DEVICE_DATA | 278 | 2 | 1/10 | | dhw.nrg2 | energy 2 | uint24 | kWh | false | DHW | 73 | 2 | 1/10 | | dhw.tapactivated | turn on/off | boolean | | true | DHW | 28 | 1 | 1 | | dhw.settemp | set temperature | uint8 | C | false | DHW | 29 | 1 | 1 | @@ -2997,10 +3015,10 @@ uint8 | dhw.starts | starts | uint24 | | false | DHW | 67 | 2 | 1 | | dhw.workm | active time | time | minutes | false | DHW | 69 | 2 | 1 | uint8 -| nompower | nominal Power | uint8 (>=0<=0) | kW | true | DEVICE_DATA | 279 | 1 | 1 | -| nrgtotal | total energy | uint24 | kWh | false | DEVICE_DATA | 88 | 2 | 1/100 | +| nompower | nominal Power | uint8 (>=0<=0) | kW | true | DEVICE_DATA | 280 | 1 | 1 | +| nrgtotal | total energy | uint24 | kWh | false | DEVICE_DATA | 89 | 2 | 1/100 | uint24 -| nrgheat | energy heating | uint24 (>=0<=10000000) | kWh | true | DEVICE_DATA | 90 | 2 | 1/100 | +| nrgheat | energy heating | uint24 (>=0<=10000000) | kWh | true | DEVICE_DATA | 91 | 2 | 1/100 | uint24 | dhw.nrg | energy | uint24 (>=0<=10000000) | kWh | true | DHW | 0 | 2 | 1/100 | @@ -3023,39 +3041,39 @@ uint8 | syspress | system pressure | uint8 | bar | false | DEVICE_DATA | 11 | 1 | 1/10 | | boiltemp | actual boiler temperature | uint16 | C | false | DEVICE_DATA | 12 | 1 | 1/10 | | headertemp | low loss header | uint16 | C | false | DEVICE_DATA | 13 | 1 | 1/10 | -| exhausttemp | exhaust temperature | uint16 | C | false | DEVICE_DATA | 253 | 1 | 1/10 | -| burngas | gas | boolean | | false | DEVICE_DATA | 254 | 1 | 1 | -| burngas2 | gas stage 2 | boolean | | false | DEVICE_DATA | 255 | 1 | 1 | -| flamecurr | flame current | uint16 | µA | false | DEVICE_DATA | 256 | 1 | 1/10 | -| fanwork | fan | boolean | | false | DEVICE_DATA | 257 | 1 | 1 | -| ignwork | ignition | boolean | | false | DEVICE_DATA | 258 | 1 | 1 | -| oilpreheat | oil preheating | boolean | | false | DEVICE_DATA | 259 | 1 | 1 | +| exhausttemp | exhaust temperature | uint16 | C | false | DEVICE_DATA | 254 | 1 | 1/10 | +| burngas | gas | boolean | | false | DEVICE_DATA | 255 | 1 | 1 | +| burngas2 | gas stage 2 | boolean | | false | DEVICE_DATA | 256 | 1 | 1 | +| flamecurr | flame current | uint16 | µA | false | DEVICE_DATA | 257 | 1 | 1/10 | +| fanwork | fan | boolean | | false | DEVICE_DATA | 258 | 1 | 1 | +| ignwork | ignition | boolean | | false | DEVICE_DATA | 259 | 1 | 1 | +| oilpreheat | oil preheating | boolean | | false | DEVICE_DATA | 260 | 1 | 1 | uint8 -| burnminpower | burner min power | uint8 (>=0<=0) | % | true | DEVICE_DATA | 260 | 1 | 1 | +| burnminpower | burner min power | uint8 (>=0<=0) | % | true | DEVICE_DATA | 261 | 1 | 1 | uint8 -| burnmaxpower | burner max power | uint8 (>=0<=254) | % | true | DEVICE_DATA | 261 | 1 | 1 | +| burnmaxpower | burner max power | uint8 (>=0<=254) | % | true | DEVICE_DATA | 262 | 1 | 1 | uint8 -| burnminperiod | burner min period | uint8 (>=0<=120) | minutes | true | DEVICE_DATA | 262 | 1 | 1 | -| absburnpow | burner current power (absolute) | uint8 | % | false | DEVICE_DATA | 263 | 1 | 1 | -| heatblock | Heatblock temperature | uint16 | C | false | DEVICE_DATA | 264 | 1 | 1/10 | +| burnminperiod | burner min period | uint8 (>=0<=120) | minutes | true | DEVICE_DATA | 263 | 1 | 1 | +| absburnpow | burner current power (absolute) | uint8 | % | false | DEVICE_DATA | 264 | 1 | 1 | +| heatblock | Heatblock temperature | uint16 | C | false | DEVICE_DATA | 265 | 1 | 1/10 | int8 -| boilhyston | hysteresis on temperature | int8 (>=-20<=0) | C | true | DEVICE_DATA | 265 | 1 | 1 | +| boilhyston | hysteresis on temperature | int8 (>=-20<=0) | C | true | DEVICE_DATA | 266 | 1 | 1 | int8 -| boilhystoff | hysteresis off temperature | int8 (>=0<=20) | C | true | DEVICE_DATA | 266 | 1 | 1 | +| boilhystoff | hysteresis off temperature | int8 (>=0<=20) | C | true | DEVICE_DATA | 267 | 1 | 1 | int8 -| boil2hyston | hysteresis stage 2 on temperature | int8 (>=-20<=0) | C | true | DEVICE_DATA | 267 | 1 | 1 | +| boil2hyston | hysteresis stage 2 on temperature | int8 (>=-20<=0) | C | true | DEVICE_DATA | 268 | 1 | 1 | int8 -| boil2hystoff | hysteresis stage 2 off temperature | int8 (>=0<=20) | C | true | DEVICE_DATA | 268 | 1 | 1 | -| curveon | heatingcurve on | boolean | | true | DEVICE_DATA | 269 | 1 | 1 | +| boil2hystoff | hysteresis stage 2 off temperature | int8 (>=0<=20) | C | true | DEVICE_DATA | 269 | 1 | 1 | +| curveon | heatingcurve on | boolean | | true | DEVICE_DATA | 270 | 1 | 1 | uint8 -| curvebase | heatingcurve base | uint8 (>=20<=90) | C | true | DEVICE_DATA | 270 | 1 | 1 | +| curvebase | heatingcurve base | uint8 (>=20<=90) | C | true | DEVICE_DATA | 271 | 1 | 1 | uint8 -| curveend | heatingcurve end | uint8 (>=20<=90) | C | true | DEVICE_DATA | 271 | 1 | 1 | +| curveend | heatingcurve end | uint8 (>=20<=90) | C | true | DEVICE_DATA | 272 | 1 | 1 | uint8 -| summertemp | summer temperature | uint8 (>=0<=45) | C | true | DEVICE_DATA | 272 | 1 | 1 | -| nofrostmode | nofrost mode | boolean | | true | DEVICE_DATA | 273 | 1 | 1 | +| summertemp | summer temperature | uint8 (>=0<=45) | C | true | DEVICE_DATA | 273 | 1 | 1 | +| nofrostmode | nofrost mode | boolean | | true | DEVICE_DATA | 274 | 1 | 1 | uint8 -| nofrosttemp | nofrost temperature | uint8 (>=0<=10) | C | true | DEVICE_DATA | 274 | 1 | 1 | +| nofrosttemp | nofrost temperature | uint8 (>=0<=10) | C | true | DEVICE_DATA | 275 | 1 | 1 | | heatingactivated | heating activated | boolean | | true | DEVICE_DATA | 14 | 1 | 1 | uint8 | heatingtemp | heating temperature | uint8 (>=0<=90) | C | true | DEVICE_DATA | 15 | 1 | 1 | @@ -3090,20 +3108,21 @@ uint16 | emergencyops | emergency operation | boolean | | true | DEVICE_DATA | 78 | 1 | 1 | uint8 | emergencytemp | emergency temperature | uint8 (>=15<=70) | C | true | DEVICE_DATA | 79 | 1 | 1 | -| pc0flow | Flow PC0 | int16 | l/h | false | DEVICE_DATA | 80 | 1 | 1 | -| pc1flow | Flow PC1 | int16 | l/h | false | DEVICE_DATA | 81 | 1 | 1 | -| pc1on | PC1 | boolean | | false | DEVICE_DATA | 82 | 1 | 1 | -| pc1rate | PC1 rate | uint8 | % | false | DEVICE_DATA | 83 | 1 | 1 | +| pc0lpm | Flow PC0 | uint16 | l/min | false | DEVICE_DATA | 80 | 1 | 1/10 | +| pc0flow | Flow PC0 | uint16 | l/h | false | DEVICE_DATA | 81 | 1 | 1 | +| pc1flow | Flow PC1 | uint16 | l/h | false | DEVICE_DATA | 82 | 1 | 1 | +| pc1on | PC1 | boolean | | false | DEVICE_DATA | 83 | 1 | 1 | +| pc1rate | PC1 rate | uint8 | % | false | DEVICE_DATA | 84 | 1 | 1 | uint8 -| pumpkickhour | pump kick hour | uint8 (>=0<=23) | hours | true | DEVICE_DATA | 84 | 1 | 1 | -| pumpkickday | pump kick day | enum | | true | DEVICE_DATA | 85 | 1 | 1 | +| pumpkickhour | pump kick hour | uint8 (>=0<=23) | hours | true | DEVICE_DATA | 85 | 1 | 1 | +| pumpkickday | pump kick day | enum | | true | DEVICE_DATA | 86 | 1 | 1 | uint16 -| pumpkickdelay | pump kick delay | uint16 (>=0<=32767) | minutes | true | DEVICE_DATA | 86 | 1 | 1 | -| meterheat | meter heating | uint24 | kWh | false | DEVICE_DATA | 100 | 2 | 1/10 | +| pumpkickdelay | pump kick delay | uint16 (>=0<=32767) | minutes | true | DEVICE_DATA | 87 | 1 | 1 | +| meterheat | meter heating | uint24 | kWh | false | DEVICE_DATA | 101 | 2 | 1/10 | | dhw.meter | meter | uint24 | kWh | false | DHW | 2 | 2 | 1/10 | -| gasmeterheat | gas meter heating | uint24 | kWh | false | DEVICE_DATA | 275 | 2 | 1/10 | +| gasmeterheat | gas meter heating | uint24 | kWh | false | DEVICE_DATA | 276 | 2 | 1/10 | | dhw.gasmeter | gas meter | uint24 | kWh | false | DHW | 71 | 2 | 1/10 | -| nrgheat2 | energy heating 2 | uint24 | kWh | false | DEVICE_DATA | 277 | 2 | 1/10 | +| nrgheat2 | energy heating 2 | uint24 | kWh | false | DEVICE_DATA | 278 | 2 | 1/10 | | dhw.nrg2 | energy 2 | uint24 | kWh | false | DHW | 73 | 2 | 1/10 | | dhw.tapactivated | turn on/off | boolean | | true | DHW | 28 | 1 | 1 | | dhw.settemp | set temperature | uint8 | C | false | DHW | 29 | 1 | 1 | @@ -3157,10 +3176,10 @@ uint8 | dhw.starts | starts | uint24 | | false | DHW | 67 | 2 | 1 | | dhw.workm | active time | time | minutes | false | DHW | 69 | 2 | 1 | uint8 -| nompower | nominal Power | uint8 (>=0<=0) | kW | true | DEVICE_DATA | 279 | 1 | 1 | -| nrgtotal | total energy | uint24 | kWh | false | DEVICE_DATA | 88 | 2 | 1/100 | +| nompower | nominal Power | uint8 (>=0<=0) | kW | true | DEVICE_DATA | 280 | 1 | 1 | +| nrgtotal | total energy | uint24 | kWh | false | DEVICE_DATA | 89 | 2 | 1/100 | uint24 -| nrgheat | energy heating | uint24 (>=0<=10000000) | kWh | true | DEVICE_DATA | 90 | 2 | 1/100 | +| nrgheat | energy heating | uint24 (>=0<=10000000) | kWh | true | DEVICE_DATA | 91 | 2 | 1/100 | uint24 | dhw.nrg | energy | uint24 (>=0<=10000000) | kWh | true | DHW | 0 | 2 | 1/100 | @@ -3183,39 +3202,39 @@ uint8 | syspress | system pressure | uint8 | bar | false | DEVICE_DATA | 11 | 1 | 1/10 | | boiltemp | actual boiler temperature | uint16 | C | false | DEVICE_DATA | 12 | 1 | 1/10 | | headertemp | low loss header | uint16 | C | false | DEVICE_DATA | 13 | 1 | 1/10 | -| exhausttemp | exhaust temperature | uint16 | C | false | DEVICE_DATA | 253 | 1 | 1/10 | -| burngas | gas | boolean | | false | DEVICE_DATA | 254 | 1 | 1 | -| burngas2 | gas stage 2 | boolean | | false | DEVICE_DATA | 255 | 1 | 1 | -| flamecurr | flame current | uint16 | µA | false | DEVICE_DATA | 256 | 1 | 1/10 | -| fanwork | fan | boolean | | false | DEVICE_DATA | 257 | 1 | 1 | -| ignwork | ignition | boolean | | false | DEVICE_DATA | 258 | 1 | 1 | -| oilpreheat | oil preheating | boolean | | false | DEVICE_DATA | 259 | 1 | 1 | +| exhausttemp | exhaust temperature | uint16 | C | false | DEVICE_DATA | 254 | 1 | 1/10 | +| burngas | gas | boolean | | false | DEVICE_DATA | 255 | 1 | 1 | +| burngas2 | gas stage 2 | boolean | | false | DEVICE_DATA | 256 | 1 | 1 | +| flamecurr | flame current | uint16 | µA | false | DEVICE_DATA | 257 | 1 | 1/10 | +| fanwork | fan | boolean | | false | DEVICE_DATA | 258 | 1 | 1 | +| ignwork | ignition | boolean | | false | DEVICE_DATA | 259 | 1 | 1 | +| oilpreheat | oil preheating | boolean | | false | DEVICE_DATA | 260 | 1 | 1 | uint8 -| burnminpower | burner min power | uint8 (>=0<=0) | % | true | DEVICE_DATA | 260 | 1 | 1 | +| burnminpower | burner min power | uint8 (>=0<=0) | % | true | DEVICE_DATA | 261 | 1 | 1 | uint8 -| burnmaxpower | burner max power | uint8 (>=0<=254) | % | true | DEVICE_DATA | 261 | 1 | 1 | +| burnmaxpower | burner max power | uint8 (>=0<=254) | % | true | DEVICE_DATA | 262 | 1 | 1 | uint8 -| burnminperiod | burner min period | uint8 (>=0<=120) | minutes | true | DEVICE_DATA | 262 | 1 | 1 | -| absburnpow | burner current power (absolute) | uint8 | % | false | DEVICE_DATA | 263 | 1 | 1 | -| heatblock | Heatblock temperature | uint16 | C | false | DEVICE_DATA | 264 | 1 | 1/10 | +| burnminperiod | burner min period | uint8 (>=0<=120) | minutes | true | DEVICE_DATA | 263 | 1 | 1 | +| absburnpow | burner current power (absolute) | uint8 | % | false | DEVICE_DATA | 264 | 1 | 1 | +| heatblock | Heatblock temperature | uint16 | C | false | DEVICE_DATA | 265 | 1 | 1/10 | int8 -| boilhyston | hysteresis on temperature | int8 (>=-20<=0) | C | true | DEVICE_DATA | 265 | 1 | 1 | +| boilhyston | hysteresis on temperature | int8 (>=-20<=0) | C | true | DEVICE_DATA | 266 | 1 | 1 | int8 -| boilhystoff | hysteresis off temperature | int8 (>=0<=20) | C | true | DEVICE_DATA | 266 | 1 | 1 | +| boilhystoff | hysteresis off temperature | int8 (>=0<=20) | C | true | DEVICE_DATA | 267 | 1 | 1 | int8 -| boil2hyston | hysteresis stage 2 on temperature | int8 (>=-20<=0) | C | true | DEVICE_DATA | 267 | 1 | 1 | +| boil2hyston | hysteresis stage 2 on temperature | int8 (>=-20<=0) | C | true | DEVICE_DATA | 268 | 1 | 1 | int8 -| boil2hystoff | hysteresis stage 2 off temperature | int8 (>=0<=20) | C | true | DEVICE_DATA | 268 | 1 | 1 | -| curveon | heatingcurve on | boolean | | true | DEVICE_DATA | 269 | 1 | 1 | +| boil2hystoff | hysteresis stage 2 off temperature | int8 (>=0<=20) | C | true | DEVICE_DATA | 269 | 1 | 1 | +| curveon | heatingcurve on | boolean | | true | DEVICE_DATA | 270 | 1 | 1 | uint8 -| curvebase | heatingcurve base | uint8 (>=20<=90) | C | true | DEVICE_DATA | 270 | 1 | 1 | +| curvebase | heatingcurve base | uint8 (>=20<=90) | C | true | DEVICE_DATA | 271 | 1 | 1 | uint8 -| curveend | heatingcurve end | uint8 (>=20<=90) | C | true | DEVICE_DATA | 271 | 1 | 1 | +| curveend | heatingcurve end | uint8 (>=20<=90) | C | true | DEVICE_DATA | 272 | 1 | 1 | uint8 -| summertemp | summer temperature | uint8 (>=0<=45) | C | true | DEVICE_DATA | 272 | 1 | 1 | -| nofrostmode | nofrost mode | boolean | | true | DEVICE_DATA | 273 | 1 | 1 | +| summertemp | summer temperature | uint8 (>=0<=45) | C | true | DEVICE_DATA | 273 | 1 | 1 | +| nofrostmode | nofrost mode | boolean | | true | DEVICE_DATA | 274 | 1 | 1 | uint8 -| nofrosttemp | nofrost temperature | uint8 (>=0<=10) | C | true | DEVICE_DATA | 274 | 1 | 1 | +| nofrosttemp | nofrost temperature | uint8 (>=0<=10) | C | true | DEVICE_DATA | 275 | 1 | 1 | | heatingactivated | heating activated | boolean | | true | DEVICE_DATA | 14 | 1 | 1 | uint8 | heatingtemp | heating temperature | uint8 (>=0<=90) | C | true | DEVICE_DATA | 15 | 1 | 1 | @@ -3250,20 +3269,21 @@ uint16 | emergencyops | emergency operation | boolean | | true | DEVICE_DATA | 78 | 1 | 1 | uint8 | emergencytemp | emergency temperature | uint8 (>=15<=70) | C | true | DEVICE_DATA | 79 | 1 | 1 | -| pc0flow | Flow PC0 | int16 | l/h | false | DEVICE_DATA | 80 | 1 | 1 | -| pc1flow | Flow PC1 | int16 | l/h | false | DEVICE_DATA | 81 | 1 | 1 | -| pc1on | PC1 | boolean | | false | DEVICE_DATA | 82 | 1 | 1 | -| pc1rate | PC1 rate | uint8 | % | false | DEVICE_DATA | 83 | 1 | 1 | +| pc0lpm | Flow PC0 | uint16 | l/min | false | DEVICE_DATA | 80 | 1 | 1/10 | +| pc0flow | Flow PC0 | uint16 | l/h | false | DEVICE_DATA | 81 | 1 | 1 | +| pc1flow | Flow PC1 | uint16 | l/h | false | DEVICE_DATA | 82 | 1 | 1 | +| pc1on | PC1 | boolean | | false | DEVICE_DATA | 83 | 1 | 1 | +| pc1rate | PC1 rate | uint8 | % | false | DEVICE_DATA | 84 | 1 | 1 | uint8 -| pumpkickhour | pump kick hour | uint8 (>=0<=23) | hours | true | DEVICE_DATA | 84 | 1 | 1 | -| pumpkickday | pump kick day | enum | | true | DEVICE_DATA | 85 | 1 | 1 | +| pumpkickhour | pump kick hour | uint8 (>=0<=23) | hours | true | DEVICE_DATA | 85 | 1 | 1 | +| pumpkickday | pump kick day | enum | | true | DEVICE_DATA | 86 | 1 | 1 | uint16 -| pumpkickdelay | pump kick delay | uint16 (>=0<=32767) | minutes | true | DEVICE_DATA | 86 | 1 | 1 | -| meterheat | meter heating | uint24 | kWh | false | DEVICE_DATA | 100 | 2 | 1/10 | +| pumpkickdelay | pump kick delay | uint16 (>=0<=32767) | minutes | true | DEVICE_DATA | 87 | 1 | 1 | +| meterheat | meter heating | uint24 | kWh | false | DEVICE_DATA | 101 | 2 | 1/10 | | dhw.meter | meter | uint24 | kWh | false | DHW | 2 | 2 | 1/10 | -| gasmeterheat | gas meter heating | uint24 | kWh | false | DEVICE_DATA | 275 | 2 | 1/10 | +| gasmeterheat | gas meter heating | uint24 | kWh | false | DEVICE_DATA | 276 | 2 | 1/10 | | dhw.gasmeter | gas meter | uint24 | kWh | false | DHW | 71 | 2 | 1/10 | -| nrgheat2 | energy heating 2 | uint24 | kWh | false | DEVICE_DATA | 277 | 2 | 1/10 | +| nrgheat2 | energy heating 2 | uint24 | kWh | false | DEVICE_DATA | 278 | 2 | 1/10 | | dhw.nrg2 | energy 2 | uint24 | kWh | false | DHW | 73 | 2 | 1/10 | | dhw.tapactivated | turn on/off | boolean | | true | DHW | 28 | 1 | 1 | | dhw.settemp | set temperature | uint8 | C | false | DHW | 29 | 1 | 1 | @@ -3317,10 +3337,10 @@ uint8 | dhw.starts | starts | uint24 | | false | DHW | 67 | 2 | 1 | | dhw.workm | active time | time | minutes | false | DHW | 69 | 2 | 1 | uint8 -| nompower | nominal Power | uint8 (>=0<=0) | kW | true | DEVICE_DATA | 279 | 1 | 1 | -| nrgtotal | total energy | uint24 | kWh | false | DEVICE_DATA | 88 | 2 | 1/100 | +| nompower | nominal Power | uint8 (>=0<=0) | kW | true | DEVICE_DATA | 280 | 1 | 1 | +| nrgtotal | total energy | uint24 | kWh | false | DEVICE_DATA | 89 | 2 | 1/100 | uint24 -| nrgheat | energy heating | uint24 (>=0<=10000000) | kWh | true | DEVICE_DATA | 90 | 2 | 1/100 | +| nrgheat | energy heating | uint24 (>=0<=10000000) | kWh | true | DEVICE_DATA | 91 | 2 | 1/100 | uint24 | dhw.nrg | energy | uint24 (>=0<=10000000) | kWh | true | DHW | 0 | 2 | 1/100 | @@ -3343,39 +3363,39 @@ uint8 | syspress | system pressure | uint8 | bar | false | DEVICE_DATA | 11 | 1 | 1/10 | | boiltemp | actual boiler temperature | uint16 | C | false | DEVICE_DATA | 12 | 1 | 1/10 | | headertemp | low loss header | uint16 | C | false | DEVICE_DATA | 13 | 1 | 1/10 | -| exhausttemp | exhaust temperature | uint16 | C | false | DEVICE_DATA | 253 | 1 | 1/10 | -| burngas | gas | boolean | | false | DEVICE_DATA | 254 | 1 | 1 | -| burngas2 | gas stage 2 | boolean | | false | DEVICE_DATA | 255 | 1 | 1 | -| flamecurr | flame current | uint16 | µA | false | DEVICE_DATA | 256 | 1 | 1/10 | -| fanwork | fan | boolean | | false | DEVICE_DATA | 257 | 1 | 1 | -| ignwork | ignition | boolean | | false | DEVICE_DATA | 258 | 1 | 1 | -| oilpreheat | oil preheating | boolean | | false | DEVICE_DATA | 259 | 1 | 1 | +| exhausttemp | exhaust temperature | uint16 | C | false | DEVICE_DATA | 254 | 1 | 1/10 | +| burngas | gas | boolean | | false | DEVICE_DATA | 255 | 1 | 1 | +| burngas2 | gas stage 2 | boolean | | false | DEVICE_DATA | 256 | 1 | 1 | +| flamecurr | flame current | uint16 | µA | false | DEVICE_DATA | 257 | 1 | 1/10 | +| fanwork | fan | boolean | | false | DEVICE_DATA | 258 | 1 | 1 | +| ignwork | ignition | boolean | | false | DEVICE_DATA | 259 | 1 | 1 | +| oilpreheat | oil preheating | boolean | | false | DEVICE_DATA | 260 | 1 | 1 | uint8 -| burnminpower | burner min power | uint8 (>=0<=0) | % | true | DEVICE_DATA | 260 | 1 | 1 | +| burnminpower | burner min power | uint8 (>=0<=0) | % | true | DEVICE_DATA | 261 | 1 | 1 | uint8 -| burnmaxpower | burner max power | uint8 (>=0<=254) | % | true | DEVICE_DATA | 261 | 1 | 1 | +| burnmaxpower | burner max power | uint8 (>=0<=254) | % | true | DEVICE_DATA | 262 | 1 | 1 | uint8 -| burnminperiod | burner min period | uint8 (>=0<=120) | minutes | true | DEVICE_DATA | 262 | 1 | 1 | -| absburnpow | burner current power (absolute) | uint8 | % | false | DEVICE_DATA | 263 | 1 | 1 | -| heatblock | Heatblock temperature | uint16 | C | false | DEVICE_DATA | 264 | 1 | 1/10 | +| burnminperiod | burner min period | uint8 (>=0<=120) | minutes | true | DEVICE_DATA | 263 | 1 | 1 | +| absburnpow | burner current power (absolute) | uint8 | % | false | DEVICE_DATA | 264 | 1 | 1 | +| heatblock | Heatblock temperature | uint16 | C | false | DEVICE_DATA | 265 | 1 | 1/10 | int8 -| boilhyston | hysteresis on temperature | int8 (>=-20<=0) | C | true | DEVICE_DATA | 265 | 1 | 1 | +| boilhyston | hysteresis on temperature | int8 (>=-20<=0) | C | true | DEVICE_DATA | 266 | 1 | 1 | int8 -| boilhystoff | hysteresis off temperature | int8 (>=0<=20) | C | true | DEVICE_DATA | 266 | 1 | 1 | +| boilhystoff | hysteresis off temperature | int8 (>=0<=20) | C | true | DEVICE_DATA | 267 | 1 | 1 | int8 -| boil2hyston | hysteresis stage 2 on temperature | int8 (>=-20<=0) | C | true | DEVICE_DATA | 267 | 1 | 1 | +| boil2hyston | hysteresis stage 2 on temperature | int8 (>=-20<=0) | C | true | DEVICE_DATA | 268 | 1 | 1 | int8 -| boil2hystoff | hysteresis stage 2 off temperature | int8 (>=0<=20) | C | true | DEVICE_DATA | 268 | 1 | 1 | -| curveon | heatingcurve on | boolean | | true | DEVICE_DATA | 269 | 1 | 1 | +| boil2hystoff | hysteresis stage 2 off temperature | int8 (>=0<=20) | C | true | DEVICE_DATA | 269 | 1 | 1 | +| curveon | heatingcurve on | boolean | | true | DEVICE_DATA | 270 | 1 | 1 | uint8 -| curvebase | heatingcurve base | uint8 (>=20<=90) | C | true | DEVICE_DATA | 270 | 1 | 1 | +| curvebase | heatingcurve base | uint8 (>=20<=90) | C | true | DEVICE_DATA | 271 | 1 | 1 | uint8 -| curveend | heatingcurve end | uint8 (>=20<=90) | C | true | DEVICE_DATA | 271 | 1 | 1 | +| curveend | heatingcurve end | uint8 (>=20<=90) | C | true | DEVICE_DATA | 272 | 1 | 1 | uint8 -| summertemp | summer temperature | uint8 (>=0<=45) | C | true | DEVICE_DATA | 272 | 1 | 1 | -| nofrostmode | nofrost mode | boolean | | true | DEVICE_DATA | 273 | 1 | 1 | +| summertemp | summer temperature | uint8 (>=0<=45) | C | true | DEVICE_DATA | 273 | 1 | 1 | +| nofrostmode | nofrost mode | boolean | | true | DEVICE_DATA | 274 | 1 | 1 | uint8 -| nofrosttemp | nofrost temperature | uint8 (>=0<=10) | C | true | DEVICE_DATA | 274 | 1 | 1 | +| nofrosttemp | nofrost temperature | uint8 (>=0<=10) | C | true | DEVICE_DATA | 275 | 1 | 1 | | heatingactivated | heating activated | boolean | | true | DEVICE_DATA | 14 | 1 | 1 | uint8 | heatingtemp | heating temperature | uint8 (>=0<=90) | C | true | DEVICE_DATA | 15 | 1 | 1 | @@ -3410,20 +3430,21 @@ uint16 | emergencyops | emergency operation | boolean | | true | DEVICE_DATA | 78 | 1 | 1 | uint8 | emergencytemp | emergency temperature | uint8 (>=15<=70) | C | true | DEVICE_DATA | 79 | 1 | 1 | -| pc0flow | Flow PC0 | int16 | l/h | false | DEVICE_DATA | 80 | 1 | 1 | -| pc1flow | Flow PC1 | int16 | l/h | false | DEVICE_DATA | 81 | 1 | 1 | -| pc1on | PC1 | boolean | | false | DEVICE_DATA | 82 | 1 | 1 | -| pc1rate | PC1 rate | uint8 | % | false | DEVICE_DATA | 83 | 1 | 1 | +| pc0lpm | Flow PC0 | uint16 | l/min | false | DEVICE_DATA | 80 | 1 | 1/10 | +| pc0flow | Flow PC0 | uint16 | l/h | false | DEVICE_DATA | 81 | 1 | 1 | +| pc1flow | Flow PC1 | uint16 | l/h | false | DEVICE_DATA | 82 | 1 | 1 | +| pc1on | PC1 | boolean | | false | DEVICE_DATA | 83 | 1 | 1 | +| pc1rate | PC1 rate | uint8 | % | false | DEVICE_DATA | 84 | 1 | 1 | uint8 -| pumpkickhour | pump kick hour | uint8 (>=0<=23) | hours | true | DEVICE_DATA | 84 | 1 | 1 | -| pumpkickday | pump kick day | enum | | true | DEVICE_DATA | 85 | 1 | 1 | +| pumpkickhour | pump kick hour | uint8 (>=0<=23) | hours | true | DEVICE_DATA | 85 | 1 | 1 | +| pumpkickday | pump kick day | enum | | true | DEVICE_DATA | 86 | 1 | 1 | uint16 -| pumpkickdelay | pump kick delay | uint16 (>=0<=32767) | minutes | true | DEVICE_DATA | 86 | 1 | 1 | -| meterheat | meter heating | uint24 | kWh | false | DEVICE_DATA | 100 | 2 | 1/10 | +| pumpkickdelay | pump kick delay | uint16 (>=0<=32767) | minutes | true | DEVICE_DATA | 87 | 1 | 1 | +| meterheat | meter heating | uint24 | kWh | false | DEVICE_DATA | 101 | 2 | 1/10 | | dhw.meter | meter | uint24 | kWh | false | DHW | 2 | 2 | 1/10 | -| gasmeterheat | gas meter heating | uint24 | kWh | false | DEVICE_DATA | 275 | 2 | 1/10 | +| gasmeterheat | gas meter heating | uint24 | kWh | false | DEVICE_DATA | 276 | 2 | 1/10 | | dhw.gasmeter | gas meter | uint24 | kWh | false | DHW | 71 | 2 | 1/10 | -| nrgheat2 | energy heating 2 | uint24 | kWh | false | DEVICE_DATA | 277 | 2 | 1/10 | +| nrgheat2 | energy heating 2 | uint24 | kWh | false | DEVICE_DATA | 278 | 2 | 1/10 | | dhw.nrg2 | energy 2 | uint24 | kWh | false | DHW | 73 | 2 | 1/10 | | dhw.tapactivated | turn on/off | boolean | | true | DHW | 28 | 1 | 1 | | dhw.settemp | set temperature | uint8 | C | false | DHW | 29 | 1 | 1 | @@ -3477,10 +3498,10 @@ uint8 | dhw.starts | starts | uint24 | | false | DHW | 67 | 2 | 1 | | dhw.workm | active time | time | minutes | false | DHW | 69 | 2 | 1 | uint8 -| nompower | nominal Power | uint8 (>=0<=0) | kW | true | DEVICE_DATA | 279 | 1 | 1 | -| nrgtotal | total energy | uint24 | kWh | false | DEVICE_DATA | 88 | 2 | 1/100 | +| nompower | nominal Power | uint8 (>=0<=0) | kW | true | DEVICE_DATA | 280 | 1 | 1 | +| nrgtotal | total energy | uint24 | kWh | false | DEVICE_DATA | 89 | 2 | 1/100 | uint24 -| nrgheat | energy heating | uint24 (>=0<=10000000) | kWh | true | DEVICE_DATA | 90 | 2 | 1/100 | +| nrgheat | energy heating | uint24 (>=0<=10000000) | kWh | true | DEVICE_DATA | 91 | 2 | 1/100 | uint24 | dhw.nrg | energy | uint24 (>=0<=10000000) | kWh | true | DHW | 0 | 2 | 1/100 | @@ -3537,152 +3558,153 @@ uint16 | emergencyops | emergency operation | boolean | | true | DEVICE_DATA | 78 | 1 | 1 | uint8 | emergencytemp | emergency temperature | uint8 (>=15<=70) | C | true | DEVICE_DATA | 79 | 1 | 1 | -| pc0flow | Flow PC0 | int16 | l/h | false | DEVICE_DATA | 80 | 1 | 1 | -| pc1flow | Flow PC1 | int16 | l/h | false | DEVICE_DATA | 81 | 1 | 1 | -| pc1on | PC1 | boolean | | false | DEVICE_DATA | 82 | 1 | 1 | -| pc1rate | PC1 rate | uint8 | % | false | DEVICE_DATA | 83 | 1 | 1 | +| pc0lpm | Flow PC0 | uint16 | l/min | false | DEVICE_DATA | 80 | 1 | 1/10 | +| pc0flow | Flow PC0 | uint16 | l/h | false | DEVICE_DATA | 81 | 1 | 1 | +| pc1flow | Flow PC1 | uint16 | l/h | false | DEVICE_DATA | 82 | 1 | 1 | +| pc1on | PC1 | boolean | | false | DEVICE_DATA | 83 | 1 | 1 | +| pc1rate | PC1 rate | uint8 | % | false | DEVICE_DATA | 84 | 1 | 1 | uint8 -| pumpkickhour | pump kick hour | uint8 (>=0<=23) | hours | true | DEVICE_DATA | 84 | 1 | 1 | -| pumpkickday | pump kick day | enum | | true | DEVICE_DATA | 85 | 1 | 1 | +| pumpkickhour | pump kick hour | uint8 (>=0<=23) | hours | true | DEVICE_DATA | 85 | 1 | 1 | +| pumpkickday | pump kick day | enum | | true | DEVICE_DATA | 86 | 1 | 1 | uint16 -| pumpkickdelay | pump kick delay | uint16 (>=0<=32767) | minutes | true | DEVICE_DATA | 86 | 1 | 1 | -| mandefrost | manual defrost | cmd | | true | DEVICE_DATA | 87 | 1 | 1 | -| nrgtotal | total energy | uint24 | kWh | false | DEVICE_DATA | 88 | 2 | 1/100 | +| pumpkickdelay | pump kick delay | uint16 (>=0<=32767) | minutes | true | DEVICE_DATA | 87 | 1 | 1 | +| mandefrost | manual defrost | cmd | | true | DEVICE_DATA | 88 | 1 | 1 | +| nrgtotal | total energy | uint24 | kWh | false | DEVICE_DATA | 89 | 2 | 1/100 | | dhw.nrg | energy | uint24 | kWh | false | DHW | 0 | 2 | 1/100 | -| nrgheat | energy heating | uint24 | kWh | false | DEVICE_DATA | 90 | 2 | 1/100 | -| nrgcool | energy cooling | uint24 | kWh | false | DEVICE_DATA | 92 | 2 | 1/100 | -| metertotal | meter total | uint24 | kWh | false | DEVICE_DATA | 94 | 2 | 1/100 | -| metercomp | meter compressor | uint24 | kWh | false | DEVICE_DATA | 96 | 2 | 1/100 | -| metereheat | meter e-heater | uint24 | kWh | false | DEVICE_DATA | 98 | 2 | 1/100 | -| meterheat | meter heating | uint24 | kWh | false | DEVICE_DATA | 100 | 2 | 1/100 | -| metercool | meter cooling | uint24 | kWh | false | DEVICE_DATA | 102 | 2 | 1/100 | +| nrgheat | energy heating | uint24 | kWh | false | DEVICE_DATA | 91 | 2 | 1/100 | +| nrgcool | energy cooling | uint24 | kWh | false | DEVICE_DATA | 93 | 2 | 1/100 | +| metertotal | meter total | uint24 | kWh | false | DEVICE_DATA | 95 | 2 | 1/100 | +| metercomp | meter compressor | uint24 | kWh | false | DEVICE_DATA | 97 | 2 | 1/100 | +| metereheat | meter e-heater | uint24 | kWh | false | DEVICE_DATA | 99 | 2 | 1/100 | +| meterheat | meter heating | uint24 | kWh | false | DEVICE_DATA | 101 | 2 | 1/100 | +| metercool | meter cooling | uint24 | kWh | false | DEVICE_DATA | 103 | 2 | 1/100 | | dhw.meter | meter | uint24 | kWh | false | DHW | 2 | 2 | 1/100 | -| uptimetotal | heatpump total uptime | time | minutes | false | DEVICE_DATA | 104 | 2 | 1/60 | -| uptimecontrol | total operating time heat | time | minutes | false | DEVICE_DATA | 106 | 2 | 1/60 | -| uptimecompheating | operating time compressor heating | time | minutes | false | DEVICE_DATA | 108 | 2 | 1/60 | -| uptimecompcooling | operating time compressor cooling | time | minutes | false | DEVICE_DATA | 110 | 2 | 1/60 | +| uptimetotal | heatpump total uptime | time | minutes | false | DEVICE_DATA | 105 | 2 | 1/60 | +| uptimecontrol | total operating time heat | time | minutes | false | DEVICE_DATA | 107 | 2 | 1/60 | +| uptimecompheating | operating time compressor heating | time | minutes | false | DEVICE_DATA | 109 | 2 | 1/60 | +| uptimecompcooling | operating time compressor cooling | time | minutes | false | DEVICE_DATA | 111 | 2 | 1/60 | | dhw.uptimecomp | operating time compressor | time | minutes | false | DHW | 4 | 2 | 1/60 | -| uptimecomppool | operating time compressor pool | time | minutes | false | DEVICE_DATA | 112 | 2 | 1/60 | -| totalcompstarts | total compressor control starts | uint24 | | false | DEVICE_DATA | 114 | 2 | 1 | -| heatingstarts | heating control starts | uint24 | | false | DEVICE_DATA | 116 | 2 | 1 | -| coolingstarts | cooling control starts | uint24 | | false | DEVICE_DATA | 118 | 2 | 1 | +| uptimecomppool | operating time compressor pool | time | minutes | false | DEVICE_DATA | 113 | 2 | 1/60 | +| totalcompstarts | total compressor control starts | uint24 | | false | DEVICE_DATA | 115 | 2 | 1 | +| heatingstarts | heating control starts | uint24 | | false | DEVICE_DATA | 117 | 2 | 1 | +| coolingstarts | cooling control starts | uint24 | | false | DEVICE_DATA | 119 | 2 | 1 | | dhw.startshp | starts hp | uint24 | | false | DHW | 6 | 2 | 1 | -| poolstarts | pool control starts | uint24 | | false | DEVICE_DATA | 120 | 2 | 1 | -| nrgconstotal | total energy consumption | uint24 | kWh | false | DEVICE_DATA | 122 | 2 | 1 | -| nrgconscomptotal | total energy consumption compressor | uint24 | kWh | false | DEVICE_DATA | 124 | 2 | 1 | -| nrgconscompheating | energy consumption compressor heating | uint24 | kWh | false | DEVICE_DATA | 126 | 2 | 1 | +| poolstarts | pool control starts | uint24 | | false | DEVICE_DATA | 121 | 2 | 1 | +| nrgconstotal | total energy consumption | uint24 | kWh | false | DEVICE_DATA | 123 | 2 | 1 | +| nrgconscomptotal | total energy consumption compressor | uint24 | kWh | false | DEVICE_DATA | 125 | 2 | 1 | +| nrgconscompheating | energy consumption compressor heating | uint24 | kWh | false | DEVICE_DATA | 127 | 2 | 1 | | dhw.nrgconscomp | energy consumption compressor | uint24 | kWh | false | DHW | 8 | 2 | 1 | -| nrgconscompcooling | energy consumption compressor cooling | uint24 | kWh | false | DEVICE_DATA | 128 | 2 | 1 | -| nrgconscomppool | energy consumption compressor pool | uint24 | kWh | false | DEVICE_DATA | 130 | 2 | 1 | -| auxelecheatnrgconstotal | total aux elec. heater energy consumption | uint24 | kWh | false | DEVICE_DATA | 132 | 2 | 1 | -| auxelecheatnrgconsheating | aux elec. heater energy consumption heating | uint24 | kWh | false | DEVICE_DATA | 134 | 2 | 1 | +| nrgconscompcooling | energy consumption compressor cooling | uint24 | kWh | false | DEVICE_DATA | 129 | 2 | 1 | +| nrgconscomppool | energy consumption compressor pool | uint24 | kWh | false | DEVICE_DATA | 131 | 2 | 1 | +| auxelecheatnrgconstotal | total aux elec. heater energy consumption | uint24 | kWh | false | DEVICE_DATA | 133 | 2 | 1 | +| auxelecheatnrgconsheating | aux elec. heater energy consumption heating | uint24 | kWh | false | DEVICE_DATA | 135 | 2 | 1 | | dhw.auxelecheatnrgcons | aux elec. heater energy consumption | uint24 | kWh | false | DHW | 10 | 2 | 1 | -| auxelecheatnrgconspool | aux elec. heater energy consumption pool | uint24 | kWh | false | DEVICE_DATA | 136 | 2 | 1 | -| nrgsupptotal | total energy supplied | uint24 | kWh | false | DEVICE_DATA | 138 | 2 | 1 | -| nrgsuppheating | total energy supplied heating | uint24 | kWh | false | DEVICE_DATA | 140 | 2 | 1 | +| auxelecheatnrgconspool | aux elec. heater energy consumption pool | uint24 | kWh | false | DEVICE_DATA | 137 | 2 | 1 | +| nrgsupptotal | total energy supplied | uint24 | kWh | false | DEVICE_DATA | 139 | 2 | 1 | +| nrgsuppheating | total energy supplied heating | uint24 | kWh | false | DEVICE_DATA | 141 | 2 | 1 | | dhw.nrgsupp | total energy warm supplied | uint24 | kWh | false | DHW | 12 | 2 | 1 | -| nrgsuppcooling | total energy supplied cooling | uint24 | kWh | false | DEVICE_DATA | 142 | 2 | 1 | -| nrgsupppool | total energy supplied pool | uint24 | kWh | false | DEVICE_DATA | 144 | 2 | 1 | -| hppower | compressor power output | uint16 | kW | false | DEVICE_DATA | 146 | 1 | 1/10 | +| nrgsuppcooling | total energy supplied cooling | uint24 | kWh | false | DEVICE_DATA | 143 | 2 | 1 | +| nrgsupppool | total energy supplied pool | uint24 | kWh | false | DEVICE_DATA | 145 | 2 | 1 | +| hppower | compressor power output | uint16 | kW | false | DEVICE_DATA | 147 | 1 | 1/10 | uint8 -| hpmaxpower | compressor max power | uint8 (>=0<=0) | % | true | DEVICE_DATA | 147 | 1 | 1 | +| hpmaxpower | compressor max power | uint8 (>=0<=0) | % | true | DEVICE_DATA | 148 | 1 | 1 | uint8 -| pvmaxcomp | pv compressor max power | uint8 (>=0<=0) | kW | true | DEVICE_DATA | 148 | 1 | 1/10 | +| pvmaxcomp | pv compressor max power | uint8 (>=0<=0) | kW | true | DEVICE_DATA | 149 | 1 | 1/10 | uint8 -| powerreduction | power reduction | uint8 (>=30<=60) | % | true | DEVICE_DATA | 149 | 1 | 10 | +| powerreduction | power reduction | uint8 (>=30<=60) | % | true | DEVICE_DATA | 150 | 1 | 10 | uint8 -| hpsetdiffpress | set differential pressure | uint8 (>=150<=750) | mbar | true | DEVICE_DATA | 150 | 1 | 50 | -| hpcompon | hp compressor | boolean | | false | DEVICE_DATA | 151 | 1 | 1 | -| hpactivity | compressor activity | enum | | false | DEVICE_DATA | 152 | 1 | 1 | -| hpbrinepumpspd | brine pump speed | uint8 | % | false | DEVICE_DATA | 153 | 1 | 1 | -| hpswitchvalve | switch valve | boolean | | false | DEVICE_DATA | 154 | 1 | 1 | -| hpcompspd | compressor speed | uint8 | % | false | DEVICE_DATA | 155 | 1 | 1 | -| hptargetspd | compressor target speed | uint8 | % | false | DEVICE_DATA | 156 | 1 | 1 | -| hpcircspd | circulation pump speed | uint8 | % | false | DEVICE_DATA | 157 | 1 | 1 | -| recvalve | receiver valve VR0 | uint8 | % | false | DEVICE_DATA | 158 | 1 | 1 | -| expvalve | expansion valve VR1 | uint8 | % | false | DEVICE_DATA | 159 | 1 | 1 | -| hpbrinein | brine in/evaporator | int16 | C | false | DEVICE_DATA | 160 | 1 | 1/10 | -| hpbrineout | brine out/condenser | int16 | C | false | DEVICE_DATA | 161 | 1 | 1/10 | -| hptc0 | heat carrier return (TC0) | int16 | C | false | DEVICE_DATA | 162 | 1 | 1/10 | -| hptc1 | heat carrier forward (TC1) | int16 | C | false | DEVICE_DATA | 163 | 1 | 1/10 | -| hptc3 | condenser temperature (TC3) | int16 | C | false | DEVICE_DATA | 164 | 1 | 1/10 | -| hptr1 | compressor temperature (TR1) | int16 | C | false | DEVICE_DATA | 165 | 1 | 1/10 | -| hptr3 | refrigerant temperature liquid side (condenser output) (TR3) | int16 | C | false | DEVICE_DATA | 166 | 1 | 1/10 | -| hptr4 | evaporator inlet temperature (TR4) | int16 | C | false | DEVICE_DATA | 167 | 1 | 1/10 | -| hptr5 | compressor inlet temperature (TR5) | int16 | C | false | DEVICE_DATA | 168 | 1 | 1/10 | -| hptr6 | compressor outlet temperature (TR6) | int16 | C | false | DEVICE_DATA | 169 | 1 | 1/10 | -| hptr7 | refrigerant temperature gas side (condenser input) (TR7) | int16 | C | false | DEVICE_DATA | 170 | 1 | 1/10 | -| hptl2 | air inlet temperature (TL2) | int16 | C | false | DEVICE_DATA | 171 | 1 | 1/10 | -| hppl1 | low pressure side temperature (PL1) | int16 | C | false | DEVICE_DATA | 172 | 1 | 1/10 | -| hpph1 | high pressure side temperature (PH1) | int16 | C | false | DEVICE_DATA | 173 | 1 | 1/10 | -| hpta4 | drain pan temp (TA4) | int16 | C | false | DEVICE_DATA | 174 | 1 | 1/10 | -| hptw1 | reservoir temp (TW1) | int16 | C | false | DEVICE_DATA | 175 | 1 | 1/10 | +| hpsetdiffpress | set differential pressure | uint8 (>=150<=750) | mbar | true | DEVICE_DATA | 151 | 1 | 50 | +| hpcompon | hp compressor | boolean | | false | DEVICE_DATA | 152 | 1 | 1 | +| hpactivity | compressor activity | enum | | false | DEVICE_DATA | 153 | 1 | 1 | +| hpbrinepumpspd | brine pump speed | uint8 | % | false | DEVICE_DATA | 154 | 1 | 1 | +| hpswitchvalve | switch valve | boolean | | false | DEVICE_DATA | 155 | 1 | 1 | +| hpcompspd | compressor speed | uint8 | % | false | DEVICE_DATA | 156 | 1 | 1 | +| hptargetspd | compressor target speed | uint8 | % | false | DEVICE_DATA | 157 | 1 | 1 | +| hpcircspd | circulation pump speed | uint8 | % | false | DEVICE_DATA | 158 | 1 | 1 | +| recvalve | receiver valve VR0 | uint8 | % | false | DEVICE_DATA | 159 | 1 | 1 | +| expvalve | expansion valve VR1 | uint8 | % | false | DEVICE_DATA | 160 | 1 | 1 | +| hpbrinein | brine in/evaporator | int16 | C | false | DEVICE_DATA | 161 | 1 | 1/10 | +| hpbrineout | brine out/condenser | int16 | C | false | DEVICE_DATA | 162 | 1 | 1/10 | +| hptc0 | heat carrier return (TC0) | int16 | C | false | DEVICE_DATA | 163 | 1 | 1/10 | +| hptc1 | heat carrier forward (TC1) | int16 | C | false | DEVICE_DATA | 164 | 1 | 1/10 | +| hptc3 | condenser temperature (TC3) | int16 | C | false | DEVICE_DATA | 165 | 1 | 1/10 | +| hptr1 | compressor temperature (TR1) | int16 | C | false | DEVICE_DATA | 166 | 1 | 1/10 | +| hptr3 | refrigerant temperature liquid side (condenser output) (TR3) | int16 | C | false | DEVICE_DATA | 167 | 1 | 1/10 | +| hptr4 | evaporator inlet temperature (TR4) | int16 | C | false | DEVICE_DATA | 168 | 1 | 1/10 | +| hptr5 | compressor inlet temperature (TR5) | int16 | C | false | DEVICE_DATA | 169 | 1 | 1/10 | +| hptr6 | compressor outlet temperature (TR6) | int16 | C | false | DEVICE_DATA | 170 | 1 | 1/10 | +| hptr7 | refrigerant temperature gas side (condenser input) (TR7) | int16 | C | false | DEVICE_DATA | 171 | 1 | 1/10 | +| hptl2 | air inlet temperature (TL2) | int16 | C | false | DEVICE_DATA | 172 | 1 | 1/10 | +| hppl1 | low pressure side temperature (PL1) | int16 | C | false | DEVICE_DATA | 173 | 1 | 1/10 | +| hpph1 | high pressure side temperature (PH1) | int16 | C | false | DEVICE_DATA | 174 | 1 | 1/10 | +| hpta4 | drain pan temp (TA4) | int16 | C | false | DEVICE_DATA | 175 | 1 | 1/10 | +| hptw1 | reservoir temp (TW1) | int16 | C | false | DEVICE_DATA | 176 | 1 | 1/10 | uint8 -| poolsettemp | pool set temperature | uint8 (>=0<=0) | C | true | DEVICE_DATA | 176 | 1 | 1/2 | -| hp4way | 4-way valve (VR4) | boolean | | false | DEVICE_DATA | 177 | 1 | 1 | -| hpin1 | input 1 state | boolean | | false | DEVICE_DATA | 178 | 1 | 1 | -| hpin1opt | input 1 options | string | | true | DEVICE_DATA | 179 | 8 | 1 | -| hpin2 | input 2 state | boolean | | false | DEVICE_DATA | 187 | 1 | 1 | -| hpin2opt | input 2 options | string | | true | DEVICE_DATA | 188 | 8 | 1 | -| hpin3 | input 3 state | boolean | | false | DEVICE_DATA | 196 | 1 | 1 | -| hpin3opt | input 3 options | string | | true | DEVICE_DATA | 197 | 8 | 1 | -| hpin4 | input 4 state | boolean | | false | DEVICE_DATA | 205 | 1 | 1 | -| hpin4opt | input 4 options | string | | true | DEVICE_DATA | 206 | 8 | 1 | -| maxheatcomp | heat limit compressor | enum | | true | DEVICE_DATA | 214 | 1 | 1 | -| maxheatheat | heat limit heating | enum | | true | DEVICE_DATA | 215 | 1 | 1 | +| poolsettemp | pool set temperature | uint8 (>=0<=0) | C | true | DEVICE_DATA | 177 | 1 | 1/2 | +| hp4way | 4-way valve (VR4) | boolean | | false | DEVICE_DATA | 178 | 1 | 1 | +| hpin1 | input 1 state | boolean | | false | DEVICE_DATA | 179 | 1 | 1 | +| hpin1opt | input 1 options | string | | true | DEVICE_DATA | 180 | 8 | 1 | +| hpin2 | input 2 state | boolean | | false | DEVICE_DATA | 188 | 1 | 1 | +| hpin2opt | input 2 options | string | | true | DEVICE_DATA | 189 | 8 | 1 | +| hpin3 | input 3 state | boolean | | false | DEVICE_DATA | 197 | 1 | 1 | +| hpin3opt | input 3 options | string | | true | DEVICE_DATA | 198 | 8 | 1 | +| hpin4 | input 4 state | boolean | | false | DEVICE_DATA | 206 | 1 | 1 | +| hpin4opt | input 4 options | string | | true | DEVICE_DATA | 207 | 8 | 1 | +| maxheatcomp | heat limit compressor | enum | | true | DEVICE_DATA | 215 | 1 | 1 | +| maxheatheat | heat limit heating | enum | | true | DEVICE_DATA | 216 | 1 | 1 | | dhw.maxheat | heat limit | enum | | true | DHW | 14 | 1 | 1 | -| auxheatersource | aux heater source | enum | | true | DEVICE_DATA | 216 | 1 | 1 | -| pvcooling | cooling only with PV | boolean | | true | DEVICE_DATA | 217 | 1 | 1 | -| auxheateronly | aux heater only | boolean | | true | DEVICE_DATA | 218 | 1 | 1 | -| auxheateroff | disable aux heater | boolean | | true | DEVICE_DATA | 219 | 1 | 1 | -| auxheaterstatus | aux heater status | enum | | false | DEVICE_DATA | 220 | 1 | 1 | -| auxheaterlevel | aux heater level | uint8 | % | false | DEVICE_DATA | 221 | 1 | 1 | +| auxheatersource | aux heater source | enum | | true | DEVICE_DATA | 217 | 1 | 1 | +| pvcooling | cooling only with PV | boolean | | true | DEVICE_DATA | 218 | 1 | 1 | +| auxheateronly | aux heater only | boolean | | true | DEVICE_DATA | 219 | 1 | 1 | +| auxheateroff | disable aux heater | boolean | | true | DEVICE_DATA | 220 | 1 | 1 | +| auxheaterstatus | aux heater status | enum | | false | DEVICE_DATA | 221 | 1 | 1 | +| auxheaterlevel | aux heater level | uint8 | % | false | DEVICE_DATA | 222 | 1 | 1 | uint16 -| auxheaterdelay | aux heater on delay | uint16 (>=10<=1000) | K*min | true | DEVICE_DATA | 222 | 1 | 10 | +| auxheaterdelay | aux heater on delay | uint16 (>=10<=1000) | K*min | true | DEVICE_DATA | 223 | 1 | 10 | uint8 -| auxmaxlimit | aux heater max limit | uint8 (>=0<=10) | K | true | DEVICE_DATA | 223 | 1 | 1/10 | +| auxmaxlimit | aux heater max limit | uint8 (>=0<=10) | K | true | DEVICE_DATA | 224 | 1 | 1/10 | uint8 -| auxlimitstart | aux heater limit start | uint8 (>=0<=10) | K | true | DEVICE_DATA | 224 | 1 | 1/10 | -| auxheatrmode | aux heater mode | enum | | true | DEVICE_DATA | 225 | 1 | 1 | +| auxlimitstart | aux heater limit start | uint8 (>=0<=10) | K | true | DEVICE_DATA | 225 | 1 | 1/10 | +| auxheatrmode | aux heater mode | enum | | true | DEVICE_DATA | 226 | 1 | 1 | uint16 -| hphystheat | on/off hyst heat | uint16 (>=50<=1500) | K*min | true | DEVICE_DATA | 226 | 1 | 5 | +| hphystheat | on/off hyst heat | uint16 (>=50<=1500) | K*min | true | DEVICE_DATA | 227 | 1 | 5 | uint16 -| hphystcool | on/off hyst cool | uint16 (>=50<=1500) | K*min | true | DEVICE_DATA | 227 | 1 | 5 | +| hphystcool | on/off hyst cool | uint16 (>=50<=1500) | K*min | true | DEVICE_DATA | 228 | 1 | 5 | uint16 -| hphystpool | on/off hyst pool | uint16 (>=50<=1500) | K*min | true | DEVICE_DATA | 228 | 1 | 5 | -| silentmode | silent mode | enum | | true | DEVICE_DATA | 229 | 1 | 1 | +| hphystpool | on/off hyst pool | uint16 (>=50<=1500) | K*min | true | DEVICE_DATA | 229 | 1 | 5 | +| silentmode | silent mode | enum | | true | DEVICE_DATA | 230 | 1 | 1 | uint8 -| silentfrom | silent mode from | uint8 (>=0<=0) | minutes | true | DEVICE_DATA | 230 | 1 | 15 | +| silentfrom | silent mode from | uint8 (>=0<=0) | minutes | true | DEVICE_DATA | 231 | 1 | 15 | uint8 -| silentto | silent mode to | uint8 (>=0<=0) | minutes | true | DEVICE_DATA | 231 | 1 | 15 | +| silentto | silent mode to | uint8 (>=0<=0) | minutes | true | DEVICE_DATA | 232 | 1 | 15 | int8 -| mintempsilent | min outside temp for silent mode | int8 (>=0<=0) | C | true | DEVICE_DATA | 232 | 1 | 1 | +| mintempsilent | min outside temp for silent mode | int8 (>=0<=0) | C | true | DEVICE_DATA | 233 | 1 | 1 | int8 -| tempparmode | outside temp parallel mode | int8 (>=0<=0) | C | true | DEVICE_DATA | 233 | 1 | 1 | -| auxheatmix | aux heater mixing valve | int8 | % | false | DEVICE_DATA | 234 | 1 | 1 | +| tempparmode | outside temp parallel mode | int8 (>=0<=0) | C | true | DEVICE_DATA | 234 | 1 | 1 | +| auxheatmix | aux heater mixing valve | int8 | % | false | DEVICE_DATA | 235 | 1 | 1 | uint8 -| tempdiffheat | temp diff TC3/TC0 heat | uint8 (>=2<=10) | K | true | DEVICE_DATA | 235 | 1 | 1/10 | +| tempdiffheat | temp diff TC3/TC0 heat | uint8 (>=2<=10) | K | true | DEVICE_DATA | 236 | 1 | 1/10 | uint8 -| tempdiffcool | temp diff TC3/TC0 cool | uint8 (>=2<=10) | K | true | DEVICE_DATA | 236 | 1 | 1/10 | -| vpcooling | valve/pump cooling | boolean | | true | DEVICE_DATA | 237 | 1 | 1 | -| heatcable | heating cable | boolean | | true | DEVICE_DATA | 238 | 1 | 1 | -| vc0valve | VC0 valve | boolean | | true | DEVICE_DATA | 239 | 1 | 1 | -| primepump | primary heatpump | boolean | | true | DEVICE_DATA | 240 | 1 | 1 | +| tempdiffcool | temp diff TC3/TC0 cool | uint8 (>=2<=10) | K | true | DEVICE_DATA | 237 | 1 | 1/10 | +| vpcooling | valve/pump cooling | boolean | | true | DEVICE_DATA | 238 | 1 | 1 | +| heatcable | heating cable | boolean | | true | DEVICE_DATA | 239 | 1 | 1 | +| vc0valve | VC0 valve | boolean | | true | DEVICE_DATA | 240 | 1 | 1 | +| primepump | primary heatpump | boolean | | true | DEVICE_DATA | 241 | 1 | 1 | uint8 -| primepumpmod | primary heatpump modulation | uint8 (>=0<=0) | % | true | DEVICE_DATA | 241 | 1 | 1 | -| hp3way | 3-way valve | boolean | | true | DEVICE_DATA | 242 | 1 | 1 | -| elheatstep1 | el. heater step 1 | boolean | | true | DEVICE_DATA | 243 | 1 | 1 | -| elheatstep2 | el. heater step 2 | boolean | | true | DEVICE_DATA | 244 | 1 | 1 | -| elheatstep3 | el. heater step 3 | boolean | | true | DEVICE_DATA | 245 | 1 | 1 | -| hpea0 | condensate reservoir heating (EA0) | boolean | | false | DEVICE_DATA | 246 | 1 | 1 | -| hppumpmode | primary heatpump mode | enum | | true | DEVICE_DATA | 247 | 1 | 1 | +| primepumpmod | primary heatpump modulation | uint8 (>=0<=0) | % | true | DEVICE_DATA | 242 | 1 | 1 | +| hp3way | 3-way valve | boolean | | true | DEVICE_DATA | 243 | 1 | 1 | +| elheatstep1 | el. heater step 1 | boolean | | true | DEVICE_DATA | 244 | 1 | 1 | +| elheatstep2 | el. heater step 2 | boolean | | true | DEVICE_DATA | 245 | 1 | 1 | +| elheatstep3 | el. heater step 3 | boolean | | true | DEVICE_DATA | 246 | 1 | 1 | +| hpea0 | condensate reservoir heating (EA0) | boolean | | false | DEVICE_DATA | 247 | 1 | 1 | +| hppumpmode | primary heatpump mode | enum | | true | DEVICE_DATA | 248 | 1 | 1 | uint8 -| fan | fan | uint8 (>=20<=100) | % | true | DEVICE_DATA | 248 | 1 | 1 | -| fanspd | fan speed | uint8 | % | false | DEVICE_DATA | 249 | 1 | 1 | -| shutdown | shutdown | cmd | | true | DEVICE_DATA | 250 | 1 | 1 | -| hpcurrpower | compressor current power | uint16 | W | false | DEVICE_DATA | 251 | 1 | 1 | +| fan | fan | uint8 (>=20<=100) | % | true | DEVICE_DATA | 249 | 1 | 1 | +| fanspd | fan speed | uint8 | % | false | DEVICE_DATA | 250 | 1 | 1 | +| shutdown | shutdown | cmd | | true | DEVICE_DATA | 251 | 1 | 1 | +| hpcurrpower | compressor current power | uint16 | W | false | DEVICE_DATA | 252 | 1 | 1 | uint16 -| hppowerlimit | power limit | uint16 (>=0<=0) | W | true | DEVICE_DATA | 252 | 1 | 1 | +| hppowerlimit | power limit | uint16 (>=0<=0) | W | true | DEVICE_DATA | 253 | 1 | 1 | | dhw.alternatingop | alternating operation | boolean | | true | DHW | 15 | 1 | 1 | uint8 | dhw.altopprioheat | prioritise heating during dhw | uint8 (>=20<=120) | minutes | true | DHW | 16 | 1 | 1 | @@ -3812,152 +3834,153 @@ uint16 | emergencyops | emergency operation | boolean | | true | DEVICE_DATA | 78 | 1 | 1 | uint8 | emergencytemp | emergency temperature | uint8 (>=15<=70) | C | true | DEVICE_DATA | 79 | 1 | 1 | -| pc0flow | Flow PC0 | int16 | l/h | false | DEVICE_DATA | 80 | 1 | 1 | -| pc1flow | Flow PC1 | int16 | l/h | false | DEVICE_DATA | 81 | 1 | 1 | -| pc1on | PC1 | boolean | | false | DEVICE_DATA | 82 | 1 | 1 | -| pc1rate | PC1 rate | uint8 | % | false | DEVICE_DATA | 83 | 1 | 1 | +| pc0lpm | Flow PC0 | uint16 | l/min | false | DEVICE_DATA | 80 | 1 | 1/10 | +| pc0flow | Flow PC0 | uint16 | l/h | false | DEVICE_DATA | 81 | 1 | 1 | +| pc1flow | Flow PC1 | uint16 | l/h | false | DEVICE_DATA | 82 | 1 | 1 | +| pc1on | PC1 | boolean | | false | DEVICE_DATA | 83 | 1 | 1 | +| pc1rate | PC1 rate | uint8 | % | false | DEVICE_DATA | 84 | 1 | 1 | uint8 -| pumpkickhour | pump kick hour | uint8 (>=0<=23) | hours | true | DEVICE_DATA | 84 | 1 | 1 | -| pumpkickday | pump kick day | enum | | true | DEVICE_DATA | 85 | 1 | 1 | +| pumpkickhour | pump kick hour | uint8 (>=0<=23) | hours | true | DEVICE_DATA | 85 | 1 | 1 | +| pumpkickday | pump kick day | enum | | true | DEVICE_DATA | 86 | 1 | 1 | uint16 -| pumpkickdelay | pump kick delay | uint16 (>=0<=32767) | minutes | true | DEVICE_DATA | 86 | 1 | 1 | -| mandefrost | manual defrost | cmd | | true | DEVICE_DATA | 87 | 1 | 1 | -| nrgtotal | total energy | uint24 | kWh | false | DEVICE_DATA | 88 | 2 | 1/100 | +| pumpkickdelay | pump kick delay | uint16 (>=0<=32767) | minutes | true | DEVICE_DATA | 87 | 1 | 1 | +| mandefrost | manual defrost | cmd | | true | DEVICE_DATA | 88 | 1 | 1 | +| nrgtotal | total energy | uint24 | kWh | false | DEVICE_DATA | 89 | 2 | 1/100 | | dhw.nrg | energy | uint24 | kWh | false | DHW | 0 | 2 | 1/100 | -| nrgheat | energy heating | uint24 | kWh | false | DEVICE_DATA | 90 | 2 | 1/100 | -| nrgcool | energy cooling | uint24 | kWh | false | DEVICE_DATA | 92 | 2 | 1/100 | -| metertotal | meter total | uint24 | kWh | false | DEVICE_DATA | 94 | 2 | 1/100 | -| metercomp | meter compressor | uint24 | kWh | false | DEVICE_DATA | 96 | 2 | 1/100 | -| metereheat | meter e-heater | uint24 | kWh | false | DEVICE_DATA | 98 | 2 | 1/100 | -| meterheat | meter heating | uint24 | kWh | false | DEVICE_DATA | 100 | 2 | 1/100 | -| metercool | meter cooling | uint24 | kWh | false | DEVICE_DATA | 102 | 2 | 1/100 | +| nrgheat | energy heating | uint24 | kWh | false | DEVICE_DATA | 91 | 2 | 1/100 | +| nrgcool | energy cooling | uint24 | kWh | false | DEVICE_DATA | 93 | 2 | 1/100 | +| metertotal | meter total | uint24 | kWh | false | DEVICE_DATA | 95 | 2 | 1/100 | +| metercomp | meter compressor | uint24 | kWh | false | DEVICE_DATA | 97 | 2 | 1/100 | +| metereheat | meter e-heater | uint24 | kWh | false | DEVICE_DATA | 99 | 2 | 1/100 | +| meterheat | meter heating | uint24 | kWh | false | DEVICE_DATA | 101 | 2 | 1/100 | +| metercool | meter cooling | uint24 | kWh | false | DEVICE_DATA | 103 | 2 | 1/100 | | dhw.meter | meter | uint24 | kWh | false | DHW | 2 | 2 | 1/100 | -| uptimetotal | heatpump total uptime | time | minutes | false | DEVICE_DATA | 104 | 2 | 1/60 | -| uptimecontrol | total operating time heat | time | minutes | false | DEVICE_DATA | 106 | 2 | 1/60 | -| uptimecompheating | operating time compressor heating | time | minutes | false | DEVICE_DATA | 108 | 2 | 1/60 | -| uptimecompcooling | operating time compressor cooling | time | minutes | false | DEVICE_DATA | 110 | 2 | 1/60 | +| uptimetotal | heatpump total uptime | time | minutes | false | DEVICE_DATA | 105 | 2 | 1/60 | +| uptimecontrol | total operating time heat | time | minutes | false | DEVICE_DATA | 107 | 2 | 1/60 | +| uptimecompheating | operating time compressor heating | time | minutes | false | DEVICE_DATA | 109 | 2 | 1/60 | +| uptimecompcooling | operating time compressor cooling | time | minutes | false | DEVICE_DATA | 111 | 2 | 1/60 | | dhw.uptimecomp | operating time compressor | time | minutes | false | DHW | 4 | 2 | 1/60 | -| uptimecomppool | operating time compressor pool | time | minutes | false | DEVICE_DATA | 112 | 2 | 1/60 | -| totalcompstarts | total compressor control starts | uint24 | | false | DEVICE_DATA | 114 | 2 | 1 | -| heatingstarts | heating control starts | uint24 | | false | DEVICE_DATA | 116 | 2 | 1 | -| coolingstarts | cooling control starts | uint24 | | false | DEVICE_DATA | 118 | 2 | 1 | +| uptimecomppool | operating time compressor pool | time | minutes | false | DEVICE_DATA | 113 | 2 | 1/60 | +| totalcompstarts | total compressor control starts | uint24 | | false | DEVICE_DATA | 115 | 2 | 1 | +| heatingstarts | heating control starts | uint24 | | false | DEVICE_DATA | 117 | 2 | 1 | +| coolingstarts | cooling control starts | uint24 | | false | DEVICE_DATA | 119 | 2 | 1 | | dhw.startshp | starts hp | uint24 | | false | DHW | 6 | 2 | 1 | -| poolstarts | pool control starts | uint24 | | false | DEVICE_DATA | 120 | 2 | 1 | -| nrgconstotal | total energy consumption | uint24 | kWh | false | DEVICE_DATA | 122 | 2 | 1 | -| nrgconscomptotal | total energy consumption compressor | uint24 | kWh | false | DEVICE_DATA | 124 | 2 | 1 | -| nrgconscompheating | energy consumption compressor heating | uint24 | kWh | false | DEVICE_DATA | 126 | 2 | 1 | +| poolstarts | pool control starts | uint24 | | false | DEVICE_DATA | 121 | 2 | 1 | +| nrgconstotal | total energy consumption | uint24 | kWh | false | DEVICE_DATA | 123 | 2 | 1 | +| nrgconscomptotal | total energy consumption compressor | uint24 | kWh | false | DEVICE_DATA | 125 | 2 | 1 | +| nrgconscompheating | energy consumption compressor heating | uint24 | kWh | false | DEVICE_DATA | 127 | 2 | 1 | | dhw.nrgconscomp | energy consumption compressor | uint24 | kWh | false | DHW | 8 | 2 | 1 | -| nrgconscompcooling | energy consumption compressor cooling | uint24 | kWh | false | DEVICE_DATA | 128 | 2 | 1 | -| nrgconscomppool | energy consumption compressor pool | uint24 | kWh | false | DEVICE_DATA | 130 | 2 | 1 | -| auxelecheatnrgconstotal | total aux elec. heater energy consumption | uint24 | kWh | false | DEVICE_DATA | 132 | 2 | 1 | -| auxelecheatnrgconsheating | aux elec. heater energy consumption heating | uint24 | kWh | false | DEVICE_DATA | 134 | 2 | 1 | +| nrgconscompcooling | energy consumption compressor cooling | uint24 | kWh | false | DEVICE_DATA | 129 | 2 | 1 | +| nrgconscomppool | energy consumption compressor pool | uint24 | kWh | false | DEVICE_DATA | 131 | 2 | 1 | +| auxelecheatnrgconstotal | total aux elec. heater energy consumption | uint24 | kWh | false | DEVICE_DATA | 133 | 2 | 1 | +| auxelecheatnrgconsheating | aux elec. heater energy consumption heating | uint24 | kWh | false | DEVICE_DATA | 135 | 2 | 1 | | dhw.auxelecheatnrgcons | aux elec. heater energy consumption | uint24 | kWh | false | DHW | 10 | 2 | 1 | -| auxelecheatnrgconspool | aux elec. heater energy consumption pool | uint24 | kWh | false | DEVICE_DATA | 136 | 2 | 1 | -| nrgsupptotal | total energy supplied | uint24 | kWh | false | DEVICE_DATA | 138 | 2 | 1 | -| nrgsuppheating | total energy supplied heating | uint24 | kWh | false | DEVICE_DATA | 140 | 2 | 1 | +| auxelecheatnrgconspool | aux elec. heater energy consumption pool | uint24 | kWh | false | DEVICE_DATA | 137 | 2 | 1 | +| nrgsupptotal | total energy supplied | uint24 | kWh | false | DEVICE_DATA | 139 | 2 | 1 | +| nrgsuppheating | total energy supplied heating | uint24 | kWh | false | DEVICE_DATA | 141 | 2 | 1 | | dhw.nrgsupp | total energy warm supplied | uint24 | kWh | false | DHW | 12 | 2 | 1 | -| nrgsuppcooling | total energy supplied cooling | uint24 | kWh | false | DEVICE_DATA | 142 | 2 | 1 | -| nrgsupppool | total energy supplied pool | uint24 | kWh | false | DEVICE_DATA | 144 | 2 | 1 | -| hppower | compressor power output | uint16 | kW | false | DEVICE_DATA | 146 | 1 | 1/10 | +| nrgsuppcooling | total energy supplied cooling | uint24 | kWh | false | DEVICE_DATA | 143 | 2 | 1 | +| nrgsupppool | total energy supplied pool | uint24 | kWh | false | DEVICE_DATA | 145 | 2 | 1 | +| hppower | compressor power output | uint16 | kW | false | DEVICE_DATA | 147 | 1 | 1/10 | uint8 -| hpmaxpower | compressor max power | uint8 (>=0<=0) | % | true | DEVICE_DATA | 147 | 1 | 1 | +| hpmaxpower | compressor max power | uint8 (>=0<=0) | % | true | DEVICE_DATA | 148 | 1 | 1 | uint8 -| pvmaxcomp | pv compressor max power | uint8 (>=0<=0) | kW | true | DEVICE_DATA | 148 | 1 | 1/10 | +| pvmaxcomp | pv compressor max power | uint8 (>=0<=0) | kW | true | DEVICE_DATA | 149 | 1 | 1/10 | uint8 -| powerreduction | power reduction | uint8 (>=30<=60) | % | true | DEVICE_DATA | 149 | 1 | 10 | +| powerreduction | power reduction | uint8 (>=30<=60) | % | true | DEVICE_DATA | 150 | 1 | 10 | uint8 -| hpsetdiffpress | set differential pressure | uint8 (>=150<=750) | mbar | true | DEVICE_DATA | 150 | 1 | 50 | -| hpcompon | hp compressor | boolean | | false | DEVICE_DATA | 151 | 1 | 1 | -| hpactivity | compressor activity | enum | | false | DEVICE_DATA | 152 | 1 | 1 | -| hpbrinepumpspd | brine pump speed | uint8 | % | false | DEVICE_DATA | 153 | 1 | 1 | -| hpswitchvalve | switch valve | boolean | | false | DEVICE_DATA | 154 | 1 | 1 | -| hpcompspd | compressor speed | uint8 | % | false | DEVICE_DATA | 155 | 1 | 1 | -| hptargetspd | compressor target speed | uint8 | % | false | DEVICE_DATA | 156 | 1 | 1 | -| hpcircspd | circulation pump speed | uint8 | % | false | DEVICE_DATA | 157 | 1 | 1 | -| recvalve | receiver valve VR0 | uint8 | % | false | DEVICE_DATA | 158 | 1 | 1 | -| expvalve | expansion valve VR1 | uint8 | % | false | DEVICE_DATA | 159 | 1 | 1 | -| hpbrinein | brine in/evaporator | int16 | C | false | DEVICE_DATA | 160 | 1 | 1/10 | -| hpbrineout | brine out/condenser | int16 | C | false | DEVICE_DATA | 161 | 1 | 1/10 | -| hptc0 | heat carrier return (TC0) | int16 | C | false | DEVICE_DATA | 162 | 1 | 1/10 | -| hptc1 | heat carrier forward (TC1) | int16 | C | false | DEVICE_DATA | 163 | 1 | 1/10 | -| hptc3 | condenser temperature (TC3) | int16 | C | false | DEVICE_DATA | 164 | 1 | 1/10 | -| hptr1 | compressor temperature (TR1) | int16 | C | false | DEVICE_DATA | 165 | 1 | 1/10 | -| hptr3 | refrigerant temperature liquid side (condenser output) (TR3) | int16 | C | false | DEVICE_DATA | 166 | 1 | 1/10 | -| hptr4 | evaporator inlet temperature (TR4) | int16 | C | false | DEVICE_DATA | 167 | 1 | 1/10 | -| hptr5 | compressor inlet temperature (TR5) | int16 | C | false | DEVICE_DATA | 168 | 1 | 1/10 | -| hptr6 | compressor outlet temperature (TR6) | int16 | C | false | DEVICE_DATA | 169 | 1 | 1/10 | -| hptr7 | refrigerant temperature gas side (condenser input) (TR7) | int16 | C | false | DEVICE_DATA | 170 | 1 | 1/10 | -| hptl2 | air inlet temperature (TL2) | int16 | C | false | DEVICE_DATA | 171 | 1 | 1/10 | -| hppl1 | low pressure side temperature (PL1) | int16 | C | false | DEVICE_DATA | 172 | 1 | 1/10 | -| hpph1 | high pressure side temperature (PH1) | int16 | C | false | DEVICE_DATA | 173 | 1 | 1/10 | -| hpta4 | drain pan temp (TA4) | int16 | C | false | DEVICE_DATA | 174 | 1 | 1/10 | -| hptw1 | reservoir temp (TW1) | int16 | C | false | DEVICE_DATA | 175 | 1 | 1/10 | +| hpsetdiffpress | set differential pressure | uint8 (>=150<=750) | mbar | true | DEVICE_DATA | 151 | 1 | 50 | +| hpcompon | hp compressor | boolean | | false | DEVICE_DATA | 152 | 1 | 1 | +| hpactivity | compressor activity | enum | | false | DEVICE_DATA | 153 | 1 | 1 | +| hpbrinepumpspd | brine pump speed | uint8 | % | false | DEVICE_DATA | 154 | 1 | 1 | +| hpswitchvalve | switch valve | boolean | | false | DEVICE_DATA | 155 | 1 | 1 | +| hpcompspd | compressor speed | uint8 | % | false | DEVICE_DATA | 156 | 1 | 1 | +| hptargetspd | compressor target speed | uint8 | % | false | DEVICE_DATA | 157 | 1 | 1 | +| hpcircspd | circulation pump speed | uint8 | % | false | DEVICE_DATA | 158 | 1 | 1 | +| recvalve | receiver valve VR0 | uint8 | % | false | DEVICE_DATA | 159 | 1 | 1 | +| expvalve | expansion valve VR1 | uint8 | % | false | DEVICE_DATA | 160 | 1 | 1 | +| hpbrinein | brine in/evaporator | int16 | C | false | DEVICE_DATA | 161 | 1 | 1/10 | +| hpbrineout | brine out/condenser | int16 | C | false | DEVICE_DATA | 162 | 1 | 1/10 | +| hptc0 | heat carrier return (TC0) | int16 | C | false | DEVICE_DATA | 163 | 1 | 1/10 | +| hptc1 | heat carrier forward (TC1) | int16 | C | false | DEVICE_DATA | 164 | 1 | 1/10 | +| hptc3 | condenser temperature (TC3) | int16 | C | false | DEVICE_DATA | 165 | 1 | 1/10 | +| hptr1 | compressor temperature (TR1) | int16 | C | false | DEVICE_DATA | 166 | 1 | 1/10 | +| hptr3 | refrigerant temperature liquid side (condenser output) (TR3) | int16 | C | false | DEVICE_DATA | 167 | 1 | 1/10 | +| hptr4 | evaporator inlet temperature (TR4) | int16 | C | false | DEVICE_DATA | 168 | 1 | 1/10 | +| hptr5 | compressor inlet temperature (TR5) | int16 | C | false | DEVICE_DATA | 169 | 1 | 1/10 | +| hptr6 | compressor outlet temperature (TR6) | int16 | C | false | DEVICE_DATA | 170 | 1 | 1/10 | +| hptr7 | refrigerant temperature gas side (condenser input) (TR7) | int16 | C | false | DEVICE_DATA | 171 | 1 | 1/10 | +| hptl2 | air inlet temperature (TL2) | int16 | C | false | DEVICE_DATA | 172 | 1 | 1/10 | +| hppl1 | low pressure side temperature (PL1) | int16 | C | false | DEVICE_DATA | 173 | 1 | 1/10 | +| hpph1 | high pressure side temperature (PH1) | int16 | C | false | DEVICE_DATA | 174 | 1 | 1/10 | +| hpta4 | drain pan temp (TA4) | int16 | C | false | DEVICE_DATA | 175 | 1 | 1/10 | +| hptw1 | reservoir temp (TW1) | int16 | C | false | DEVICE_DATA | 176 | 1 | 1/10 | uint8 -| poolsettemp | pool set temperature | uint8 (>=0<=0) | C | true | DEVICE_DATA | 176 | 1 | 1/2 | -| hp4way | 4-way valve (VR4) | boolean | | false | DEVICE_DATA | 177 | 1 | 1 | -| hpin1 | input 1 state | boolean | | false | DEVICE_DATA | 178 | 1 | 1 | -| hpin1opt | input 1 options | string | | true | DEVICE_DATA | 179 | 8 | 1 | -| hpin2 | input 2 state | boolean | | false | DEVICE_DATA | 187 | 1 | 1 | -| hpin2opt | input 2 options | string | | true | DEVICE_DATA | 188 | 8 | 1 | -| hpin3 | input 3 state | boolean | | false | DEVICE_DATA | 196 | 1 | 1 | -| hpin3opt | input 3 options | string | | true | DEVICE_DATA | 197 | 8 | 1 | -| hpin4 | input 4 state | boolean | | false | DEVICE_DATA | 205 | 1 | 1 | -| hpin4opt | input 4 options | string | | true | DEVICE_DATA | 206 | 8 | 1 | -| maxheatcomp | heat limit compressor | enum | | true | DEVICE_DATA | 214 | 1 | 1 | -| maxheatheat | heat limit heating | enum | | true | DEVICE_DATA | 215 | 1 | 1 | +| poolsettemp | pool set temperature | uint8 (>=0<=0) | C | true | DEVICE_DATA | 177 | 1 | 1/2 | +| hp4way | 4-way valve (VR4) | boolean | | false | DEVICE_DATA | 178 | 1 | 1 | +| hpin1 | input 1 state | boolean | | false | DEVICE_DATA | 179 | 1 | 1 | +| hpin1opt | input 1 options | string | | true | DEVICE_DATA | 180 | 8 | 1 | +| hpin2 | input 2 state | boolean | | false | DEVICE_DATA | 188 | 1 | 1 | +| hpin2opt | input 2 options | string | | true | DEVICE_DATA | 189 | 8 | 1 | +| hpin3 | input 3 state | boolean | | false | DEVICE_DATA | 197 | 1 | 1 | +| hpin3opt | input 3 options | string | | true | DEVICE_DATA | 198 | 8 | 1 | +| hpin4 | input 4 state | boolean | | false | DEVICE_DATA | 206 | 1 | 1 | +| hpin4opt | input 4 options | string | | true | DEVICE_DATA | 207 | 8 | 1 | +| maxheatcomp | heat limit compressor | enum | | true | DEVICE_DATA | 215 | 1 | 1 | +| maxheatheat | heat limit heating | enum | | true | DEVICE_DATA | 216 | 1 | 1 | | dhw.maxheat | heat limit | enum | | true | DHW | 14 | 1 | 1 | -| auxheatersource | aux heater source | enum | | true | DEVICE_DATA | 216 | 1 | 1 | -| pvcooling | cooling only with PV | boolean | | true | DEVICE_DATA | 217 | 1 | 1 | -| auxheateronly | aux heater only | boolean | | true | DEVICE_DATA | 218 | 1 | 1 | -| auxheateroff | disable aux heater | boolean | | true | DEVICE_DATA | 219 | 1 | 1 | -| auxheaterstatus | aux heater status | enum | | false | DEVICE_DATA | 220 | 1 | 1 | -| auxheaterlevel | aux heater level | uint8 | % | false | DEVICE_DATA | 221 | 1 | 1 | +| auxheatersource | aux heater source | enum | | true | DEVICE_DATA | 217 | 1 | 1 | +| pvcooling | cooling only with PV | boolean | | true | DEVICE_DATA | 218 | 1 | 1 | +| auxheateronly | aux heater only | boolean | | true | DEVICE_DATA | 219 | 1 | 1 | +| auxheateroff | disable aux heater | boolean | | true | DEVICE_DATA | 220 | 1 | 1 | +| auxheaterstatus | aux heater status | enum | | false | DEVICE_DATA | 221 | 1 | 1 | +| auxheaterlevel | aux heater level | uint8 | % | false | DEVICE_DATA | 222 | 1 | 1 | uint16 -| auxheaterdelay | aux heater on delay | uint16 (>=10<=1000) | K*min | true | DEVICE_DATA | 222 | 1 | 10 | +| auxheaterdelay | aux heater on delay | uint16 (>=10<=1000) | K*min | true | DEVICE_DATA | 223 | 1 | 10 | uint8 -| auxmaxlimit | aux heater max limit | uint8 (>=0<=10) | K | true | DEVICE_DATA | 223 | 1 | 1/10 | +| auxmaxlimit | aux heater max limit | uint8 (>=0<=10) | K | true | DEVICE_DATA | 224 | 1 | 1/10 | uint8 -| auxlimitstart | aux heater limit start | uint8 (>=0<=10) | K | true | DEVICE_DATA | 224 | 1 | 1/10 | -| auxheatrmode | aux heater mode | enum | | true | DEVICE_DATA | 225 | 1 | 1 | +| auxlimitstart | aux heater limit start | uint8 (>=0<=10) | K | true | DEVICE_DATA | 225 | 1 | 1/10 | +| auxheatrmode | aux heater mode | enum | | true | DEVICE_DATA | 226 | 1 | 1 | uint16 -| hphystheat | on/off hyst heat | uint16 (>=50<=1500) | K*min | true | DEVICE_DATA | 226 | 1 | 5 | +| hphystheat | on/off hyst heat | uint16 (>=50<=1500) | K*min | true | DEVICE_DATA | 227 | 1 | 5 | uint16 -| hphystcool | on/off hyst cool | uint16 (>=50<=1500) | K*min | true | DEVICE_DATA | 227 | 1 | 5 | +| hphystcool | on/off hyst cool | uint16 (>=50<=1500) | K*min | true | DEVICE_DATA | 228 | 1 | 5 | uint16 -| hphystpool | on/off hyst pool | uint16 (>=50<=1500) | K*min | true | DEVICE_DATA | 228 | 1 | 5 | -| silentmode | silent mode | enum | | true | DEVICE_DATA | 229 | 1 | 1 | +| hphystpool | on/off hyst pool | uint16 (>=50<=1500) | K*min | true | DEVICE_DATA | 229 | 1 | 5 | +| silentmode | silent mode | enum | | true | DEVICE_DATA | 230 | 1 | 1 | uint8 -| silentfrom | silent mode from | uint8 (>=0<=0) | minutes | true | DEVICE_DATA | 230 | 1 | 15 | +| silentfrom | silent mode from | uint8 (>=0<=0) | minutes | true | DEVICE_DATA | 231 | 1 | 15 | uint8 -| silentto | silent mode to | uint8 (>=0<=0) | minutes | true | DEVICE_DATA | 231 | 1 | 15 | +| silentto | silent mode to | uint8 (>=0<=0) | minutes | true | DEVICE_DATA | 232 | 1 | 15 | int8 -| mintempsilent | min outside temp for silent mode | int8 (>=0<=0) | C | true | DEVICE_DATA | 232 | 1 | 1 | +| mintempsilent | min outside temp for silent mode | int8 (>=0<=0) | C | true | DEVICE_DATA | 233 | 1 | 1 | int8 -| tempparmode | outside temp parallel mode | int8 (>=0<=0) | C | true | DEVICE_DATA | 233 | 1 | 1 | -| auxheatmix | aux heater mixing valve | int8 | % | false | DEVICE_DATA | 234 | 1 | 1 | +| tempparmode | outside temp parallel mode | int8 (>=0<=0) | C | true | DEVICE_DATA | 234 | 1 | 1 | +| auxheatmix | aux heater mixing valve | int8 | % | false | DEVICE_DATA | 235 | 1 | 1 | uint8 -| tempdiffheat | temp diff TC3/TC0 heat | uint8 (>=2<=10) | K | true | DEVICE_DATA | 235 | 1 | 1/10 | +| tempdiffheat | temp diff TC3/TC0 heat | uint8 (>=2<=10) | K | true | DEVICE_DATA | 236 | 1 | 1/10 | uint8 -| tempdiffcool | temp diff TC3/TC0 cool | uint8 (>=2<=10) | K | true | DEVICE_DATA | 236 | 1 | 1/10 | -| vpcooling | valve/pump cooling | boolean | | true | DEVICE_DATA | 237 | 1 | 1 | -| heatcable | heating cable | boolean | | true | DEVICE_DATA | 238 | 1 | 1 | -| vc0valve | VC0 valve | boolean | | true | DEVICE_DATA | 239 | 1 | 1 | -| primepump | primary heatpump | boolean | | true | DEVICE_DATA | 240 | 1 | 1 | +| tempdiffcool | temp diff TC3/TC0 cool | uint8 (>=2<=10) | K | true | DEVICE_DATA | 237 | 1 | 1/10 | +| vpcooling | valve/pump cooling | boolean | | true | DEVICE_DATA | 238 | 1 | 1 | +| heatcable | heating cable | boolean | | true | DEVICE_DATA | 239 | 1 | 1 | +| vc0valve | VC0 valve | boolean | | true | DEVICE_DATA | 240 | 1 | 1 | +| primepump | primary heatpump | boolean | | true | DEVICE_DATA | 241 | 1 | 1 | uint8 -| primepumpmod | primary heatpump modulation | uint8 (>=0<=0) | % | true | DEVICE_DATA | 241 | 1 | 1 | -| hp3way | 3-way valve | boolean | | true | DEVICE_DATA | 242 | 1 | 1 | -| elheatstep1 | el. heater step 1 | boolean | | true | DEVICE_DATA | 243 | 1 | 1 | -| elheatstep2 | el. heater step 2 | boolean | | true | DEVICE_DATA | 244 | 1 | 1 | -| elheatstep3 | el. heater step 3 | boolean | | true | DEVICE_DATA | 245 | 1 | 1 | -| hpea0 | condensate reservoir heating (EA0) | boolean | | false | DEVICE_DATA | 246 | 1 | 1 | -| hppumpmode | primary heatpump mode | enum | | true | DEVICE_DATA | 247 | 1 | 1 | +| primepumpmod | primary heatpump modulation | uint8 (>=0<=0) | % | true | DEVICE_DATA | 242 | 1 | 1 | +| hp3way | 3-way valve | boolean | | true | DEVICE_DATA | 243 | 1 | 1 | +| elheatstep1 | el. heater step 1 | boolean | | true | DEVICE_DATA | 244 | 1 | 1 | +| elheatstep2 | el. heater step 2 | boolean | | true | DEVICE_DATA | 245 | 1 | 1 | +| elheatstep3 | el. heater step 3 | boolean | | true | DEVICE_DATA | 246 | 1 | 1 | +| hpea0 | condensate reservoir heating (EA0) | boolean | | false | DEVICE_DATA | 247 | 1 | 1 | +| hppumpmode | primary heatpump mode | enum | | true | DEVICE_DATA | 248 | 1 | 1 | uint8 -| fan | fan | uint8 (>=20<=100) | % | true | DEVICE_DATA | 248 | 1 | 1 | -| fanspd | fan speed | uint8 | % | false | DEVICE_DATA | 249 | 1 | 1 | -| shutdown | shutdown | cmd | | true | DEVICE_DATA | 250 | 1 | 1 | -| hpcurrpower | compressor current power | uint16 | W | false | DEVICE_DATA | 251 | 1 | 1 | +| fan | fan | uint8 (>=20<=100) | % | true | DEVICE_DATA | 249 | 1 | 1 | +| fanspd | fan speed | uint8 | % | false | DEVICE_DATA | 250 | 1 | 1 | +| shutdown | shutdown | cmd | | true | DEVICE_DATA | 251 | 1 | 1 | +| hpcurrpower | compressor current power | uint16 | W | false | DEVICE_DATA | 252 | 1 | 1 | uint16 -| hppowerlimit | power limit | uint16 (>=0<=0) | W | true | DEVICE_DATA | 252 | 1 | 1 | +| hppowerlimit | power limit | uint16 (>=0<=0) | W | true | DEVICE_DATA | 253 | 1 | 1 | | dhw.alternatingop | alternating operation | boolean | | true | DHW | 15 | 1 | 1 | uint8 | dhw.altopprioheat | prioritise heating during dhw | uint8 (>=20<=120) | minutes | true | DHW | 16 | 1 | 1 | @@ -4053,39 +4076,39 @@ uint8 | syspress | system pressure | uint8 | bar | false | DEVICE_DATA | 11 | 1 | 1/10 | | boiltemp | actual boiler temperature | uint16 | C | false | DEVICE_DATA | 12 | 1 | 1/10 | | headertemp | low loss header | uint16 | C | false | DEVICE_DATA | 13 | 1 | 1/10 | -| exhausttemp | exhaust temperature | uint16 | C | false | DEVICE_DATA | 253 | 1 | 1/10 | -| burngas | gas | boolean | | false | DEVICE_DATA | 254 | 1 | 1 | -| burngas2 | gas stage 2 | boolean | | false | DEVICE_DATA | 255 | 1 | 1 | -| flamecurr | flame current | uint16 | µA | false | DEVICE_DATA | 256 | 1 | 1/10 | -| fanwork | fan | boolean | | false | DEVICE_DATA | 257 | 1 | 1 | -| ignwork | ignition | boolean | | false | DEVICE_DATA | 258 | 1 | 1 | -| oilpreheat | oil preheating | boolean | | false | DEVICE_DATA | 259 | 1 | 1 | +| exhausttemp | exhaust temperature | uint16 | C | false | DEVICE_DATA | 254 | 1 | 1/10 | +| burngas | gas | boolean | | false | DEVICE_DATA | 255 | 1 | 1 | +| burngas2 | gas stage 2 | boolean | | false | DEVICE_DATA | 256 | 1 | 1 | +| flamecurr | flame current | uint16 | µA | false | DEVICE_DATA | 257 | 1 | 1/10 | +| fanwork | fan | boolean | | false | DEVICE_DATA | 258 | 1 | 1 | +| ignwork | ignition | boolean | | false | DEVICE_DATA | 259 | 1 | 1 | +| oilpreheat | oil preheating | boolean | | false | DEVICE_DATA | 260 | 1 | 1 | uint8 -| burnminpower | burner min power | uint8 (>=0<=0) | % | true | DEVICE_DATA | 260 | 1 | 1 | +| burnminpower | burner min power | uint8 (>=0<=0) | % | true | DEVICE_DATA | 261 | 1 | 1 | uint8 -| burnmaxpower | burner max power | uint8 (>=0<=254) | % | true | DEVICE_DATA | 261 | 1 | 1 | +| burnmaxpower | burner max power | uint8 (>=0<=254) | % | true | DEVICE_DATA | 262 | 1 | 1 | uint8 -| burnminperiod | burner min period | uint8 (>=0<=120) | minutes | true | DEVICE_DATA | 262 | 1 | 1 | -| absburnpow | burner current power (absolute) | uint8 | % | false | DEVICE_DATA | 263 | 1 | 1 | -| heatblock | Heatblock temperature | uint16 | C | false | DEVICE_DATA | 264 | 1 | 1/10 | +| burnminperiod | burner min period | uint8 (>=0<=120) | minutes | true | DEVICE_DATA | 263 | 1 | 1 | +| absburnpow | burner current power (absolute) | uint8 | % | false | DEVICE_DATA | 264 | 1 | 1 | +| heatblock | Heatblock temperature | uint16 | C | false | DEVICE_DATA | 265 | 1 | 1/10 | int8 -| boilhyston | hysteresis on temperature | int8 (>=-20<=0) | C | true | DEVICE_DATA | 265 | 1 | 1 | +| boilhyston | hysteresis on temperature | int8 (>=-20<=0) | C | true | DEVICE_DATA | 266 | 1 | 1 | int8 -| boilhystoff | hysteresis off temperature | int8 (>=0<=20) | C | true | DEVICE_DATA | 266 | 1 | 1 | +| boilhystoff | hysteresis off temperature | int8 (>=0<=20) | C | true | DEVICE_DATA | 267 | 1 | 1 | int8 -| boil2hyston | hysteresis stage 2 on temperature | int8 (>=-20<=0) | C | true | DEVICE_DATA | 267 | 1 | 1 | +| boil2hyston | hysteresis stage 2 on temperature | int8 (>=-20<=0) | C | true | DEVICE_DATA | 268 | 1 | 1 | int8 -| boil2hystoff | hysteresis stage 2 off temperature | int8 (>=0<=20) | C | true | DEVICE_DATA | 268 | 1 | 1 | -| curveon | heatingcurve on | boolean | | true | DEVICE_DATA | 269 | 1 | 1 | +| boil2hystoff | hysteresis stage 2 off temperature | int8 (>=0<=20) | C | true | DEVICE_DATA | 269 | 1 | 1 | +| curveon | heatingcurve on | boolean | | true | DEVICE_DATA | 270 | 1 | 1 | uint8 -| curvebase | heatingcurve base | uint8 (>=20<=90) | C | true | DEVICE_DATA | 270 | 1 | 1 | +| curvebase | heatingcurve base | uint8 (>=20<=90) | C | true | DEVICE_DATA | 271 | 1 | 1 | uint8 -| curveend | heatingcurve end | uint8 (>=20<=90) | C | true | DEVICE_DATA | 271 | 1 | 1 | +| curveend | heatingcurve end | uint8 (>=20<=90) | C | true | DEVICE_DATA | 272 | 1 | 1 | uint8 -| summertemp | summer temperature | uint8 (>=0<=45) | C | true | DEVICE_DATA | 272 | 1 | 1 | -| nofrostmode | nofrost mode | boolean | | true | DEVICE_DATA | 273 | 1 | 1 | +| summertemp | summer temperature | uint8 (>=0<=45) | C | true | DEVICE_DATA | 273 | 1 | 1 | +| nofrostmode | nofrost mode | boolean | | true | DEVICE_DATA | 274 | 1 | 1 | uint8 -| nofrosttemp | nofrost temperature | uint8 (>=0<=10) | C | true | DEVICE_DATA | 274 | 1 | 1 | +| nofrosttemp | nofrost temperature | uint8 (>=0<=10) | C | true | DEVICE_DATA | 275 | 1 | 1 | | heatingactivated | heating activated | boolean | | true | DEVICE_DATA | 14 | 1 | 1 | uint8 | heatingtemp | heating temperature | uint8 (>=0<=90) | C | true | DEVICE_DATA | 15 | 1 | 1 | @@ -4120,20 +4143,21 @@ uint16 | emergencyops | emergency operation | boolean | | true | DEVICE_DATA | 78 | 1 | 1 | uint8 | emergencytemp | emergency temperature | uint8 (>=15<=70) | C | true | DEVICE_DATA | 79 | 1 | 1 | -| pc0flow | Flow PC0 | int16 | l/h | false | DEVICE_DATA | 80 | 1 | 1 | -| pc1flow | Flow PC1 | int16 | l/h | false | DEVICE_DATA | 81 | 1 | 1 | -| pc1on | PC1 | boolean | | false | DEVICE_DATA | 82 | 1 | 1 | -| pc1rate | PC1 rate | uint8 | % | false | DEVICE_DATA | 83 | 1 | 1 | +| pc0lpm | Flow PC0 | uint16 | l/min | false | DEVICE_DATA | 80 | 1 | 1/10 | +| pc0flow | Flow PC0 | uint16 | l/h | false | DEVICE_DATA | 81 | 1 | 1 | +| pc1flow | Flow PC1 | uint16 | l/h | false | DEVICE_DATA | 82 | 1 | 1 | +| pc1on | PC1 | boolean | | false | DEVICE_DATA | 83 | 1 | 1 | +| pc1rate | PC1 rate | uint8 | % | false | DEVICE_DATA | 84 | 1 | 1 | uint8 -| pumpkickhour | pump kick hour | uint8 (>=0<=23) | hours | true | DEVICE_DATA | 84 | 1 | 1 | -| pumpkickday | pump kick day | enum | | true | DEVICE_DATA | 85 | 1 | 1 | +| pumpkickhour | pump kick hour | uint8 (>=0<=23) | hours | true | DEVICE_DATA | 85 | 1 | 1 | +| pumpkickday | pump kick day | enum | | true | DEVICE_DATA | 86 | 1 | 1 | uint16 -| pumpkickdelay | pump kick delay | uint16 (>=0<=32767) | minutes | true | DEVICE_DATA | 86 | 1 | 1 | -| meterheat | meter heating | uint24 | kWh | false | DEVICE_DATA | 100 | 2 | 1/10 | +| pumpkickdelay | pump kick delay | uint16 (>=0<=32767) | minutes | true | DEVICE_DATA | 87 | 1 | 1 | +| meterheat | meter heating | uint24 | kWh | false | DEVICE_DATA | 101 | 2 | 1/10 | | dhw.meter | meter | uint24 | kWh | false | DHW | 2 | 2 | 1/10 | -| gasmeterheat | gas meter heating | uint24 | kWh | false | DEVICE_DATA | 275 | 2 | 1/10 | +| gasmeterheat | gas meter heating | uint24 | kWh | false | DEVICE_DATA | 276 | 2 | 1/10 | | dhw.gasmeter | gas meter | uint24 | kWh | false | DHW | 71 | 2 | 1/10 | -| nrgheat2 | energy heating 2 | uint24 | kWh | false | DEVICE_DATA | 277 | 2 | 1/10 | +| nrgheat2 | energy heating 2 | uint24 | kWh | false | DEVICE_DATA | 278 | 2 | 1/10 | | dhw.nrg2 | energy 2 | uint24 | kWh | false | DHW | 73 | 2 | 1/10 | | dhw.tapactivated | turn on/off | boolean | | true | DHW | 28 | 1 | 1 | | dhw.settemp | set temperature | uint8 | C | false | DHW | 29 | 1 | 1 | @@ -4187,10 +4211,10 @@ uint8 | dhw.starts | starts | uint24 | | false | DHW | 67 | 2 | 1 | | dhw.workm | active time | time | minutes | false | DHW | 69 | 2 | 1 | uint8 -| nompower | nominal Power | uint8 (>=0<=0) | kW | true | DEVICE_DATA | 279 | 1 | 1 | -| nrgtotal | total energy | uint24 | kWh | false | DEVICE_DATA | 88 | 2 | 1/100 | +| nompower | nominal Power | uint8 (>=0<=0) | kW | true | DEVICE_DATA | 280 | 1 | 1 | +| nrgtotal | total energy | uint24 | kWh | false | DEVICE_DATA | 89 | 2 | 1/100 | uint24 -| nrgheat | energy heating | uint24 (>=0<=10000000) | kWh | true | DEVICE_DATA | 90 | 2 | 1/100 | +| nrgheat | energy heating | uint24 (>=0<=10000000) | kWh | true | DEVICE_DATA | 91 | 2 | 1/100 | uint24 | dhw.nrg | energy | uint24 (>=0<=10000000) | kWh | true | DHW | 0 | 2 | 1/100 | @@ -4213,39 +4237,39 @@ uint8 | syspress | system pressure | uint8 | bar | false | DEVICE_DATA | 11 | 1 | 1/10 | | boiltemp | actual boiler temperature | uint16 | C | false | DEVICE_DATA | 12 | 1 | 1/10 | | headertemp | low loss header | uint16 | C | false | DEVICE_DATA | 13 | 1 | 1/10 | -| exhausttemp | exhaust temperature | uint16 | C | false | DEVICE_DATA | 253 | 1 | 1/10 | -| burngas | gas | boolean | | false | DEVICE_DATA | 254 | 1 | 1 | -| burngas2 | gas stage 2 | boolean | | false | DEVICE_DATA | 255 | 1 | 1 | -| flamecurr | flame current | uint16 | µA | false | DEVICE_DATA | 256 | 1 | 1/10 | -| fanwork | fan | boolean | | false | DEVICE_DATA | 257 | 1 | 1 | -| ignwork | ignition | boolean | | false | DEVICE_DATA | 258 | 1 | 1 | -| oilpreheat | oil preheating | boolean | | false | DEVICE_DATA | 259 | 1 | 1 | +| exhausttemp | exhaust temperature | uint16 | C | false | DEVICE_DATA | 254 | 1 | 1/10 | +| burngas | gas | boolean | | false | DEVICE_DATA | 255 | 1 | 1 | +| burngas2 | gas stage 2 | boolean | | false | DEVICE_DATA | 256 | 1 | 1 | +| flamecurr | flame current | uint16 | µA | false | DEVICE_DATA | 257 | 1 | 1/10 | +| fanwork | fan | boolean | | false | DEVICE_DATA | 258 | 1 | 1 | +| ignwork | ignition | boolean | | false | DEVICE_DATA | 259 | 1 | 1 | +| oilpreheat | oil preheating | boolean | | false | DEVICE_DATA | 260 | 1 | 1 | uint8 -| burnminpower | burner min power | uint8 (>=0<=0) | % | true | DEVICE_DATA | 260 | 1 | 1 | +| burnminpower | burner min power | uint8 (>=0<=0) | % | true | DEVICE_DATA | 261 | 1 | 1 | uint8 -| burnmaxpower | burner max power | uint8 (>=0<=254) | % | true | DEVICE_DATA | 261 | 1 | 1 | +| burnmaxpower | burner max power | uint8 (>=0<=254) | % | true | DEVICE_DATA | 262 | 1 | 1 | uint8 -| burnminperiod | burner min period | uint8 (>=0<=120) | minutes | true | DEVICE_DATA | 262 | 1 | 1 | -| absburnpow | burner current power (absolute) | uint8 | % | false | DEVICE_DATA | 263 | 1 | 1 | -| heatblock | Heatblock temperature | uint16 | C | false | DEVICE_DATA | 264 | 1 | 1/10 | +| burnminperiod | burner min period | uint8 (>=0<=120) | minutes | true | DEVICE_DATA | 263 | 1 | 1 | +| absburnpow | burner current power (absolute) | uint8 | % | false | DEVICE_DATA | 264 | 1 | 1 | +| heatblock | Heatblock temperature | uint16 | C | false | DEVICE_DATA | 265 | 1 | 1/10 | int8 -| boilhyston | hysteresis on temperature | int8 (>=-20<=0) | C | true | DEVICE_DATA | 265 | 1 | 1 | +| boilhyston | hysteresis on temperature | int8 (>=-20<=0) | C | true | DEVICE_DATA | 266 | 1 | 1 | int8 -| boilhystoff | hysteresis off temperature | int8 (>=0<=20) | C | true | DEVICE_DATA | 266 | 1 | 1 | +| boilhystoff | hysteresis off temperature | int8 (>=0<=20) | C | true | DEVICE_DATA | 267 | 1 | 1 | int8 -| boil2hyston | hysteresis stage 2 on temperature | int8 (>=-20<=0) | C | true | DEVICE_DATA | 267 | 1 | 1 | +| boil2hyston | hysteresis stage 2 on temperature | int8 (>=-20<=0) | C | true | DEVICE_DATA | 268 | 1 | 1 | int8 -| boil2hystoff | hysteresis stage 2 off temperature | int8 (>=0<=20) | C | true | DEVICE_DATA | 268 | 1 | 1 | -| curveon | heatingcurve on | boolean | | true | DEVICE_DATA | 269 | 1 | 1 | +| boil2hystoff | hysteresis stage 2 off temperature | int8 (>=0<=20) | C | true | DEVICE_DATA | 269 | 1 | 1 | +| curveon | heatingcurve on | boolean | | true | DEVICE_DATA | 270 | 1 | 1 | uint8 -| curvebase | heatingcurve base | uint8 (>=20<=90) | C | true | DEVICE_DATA | 270 | 1 | 1 | +| curvebase | heatingcurve base | uint8 (>=20<=90) | C | true | DEVICE_DATA | 271 | 1 | 1 | uint8 -| curveend | heatingcurve end | uint8 (>=20<=90) | C | true | DEVICE_DATA | 271 | 1 | 1 | +| curveend | heatingcurve end | uint8 (>=20<=90) | C | true | DEVICE_DATA | 272 | 1 | 1 | uint8 -| summertemp | summer temperature | uint8 (>=0<=45) | C | true | DEVICE_DATA | 272 | 1 | 1 | -| nofrostmode | nofrost mode | boolean | | true | DEVICE_DATA | 273 | 1 | 1 | +| summertemp | summer temperature | uint8 (>=0<=45) | C | true | DEVICE_DATA | 273 | 1 | 1 | +| nofrostmode | nofrost mode | boolean | | true | DEVICE_DATA | 274 | 1 | 1 | uint8 -| nofrosttemp | nofrost temperature | uint8 (>=0<=10) | C | true | DEVICE_DATA | 274 | 1 | 1 | +| nofrosttemp | nofrost temperature | uint8 (>=0<=10) | C | true | DEVICE_DATA | 275 | 1 | 1 | | heatingactivated | heating activated | boolean | | true | DEVICE_DATA | 14 | 1 | 1 | uint8 | heatingtemp | heating temperature | uint8 (>=0<=90) | C | true | DEVICE_DATA | 15 | 1 | 1 | @@ -4280,20 +4304,21 @@ uint16 | emergencyops | emergency operation | boolean | | true | DEVICE_DATA | 78 | 1 | 1 | uint8 | emergencytemp | emergency temperature | uint8 (>=15<=70) | C | true | DEVICE_DATA | 79 | 1 | 1 | -| pc0flow | Flow PC0 | int16 | l/h | false | DEVICE_DATA | 80 | 1 | 1 | -| pc1flow | Flow PC1 | int16 | l/h | false | DEVICE_DATA | 81 | 1 | 1 | -| pc1on | PC1 | boolean | | false | DEVICE_DATA | 82 | 1 | 1 | -| pc1rate | PC1 rate | uint8 | % | false | DEVICE_DATA | 83 | 1 | 1 | +| pc0lpm | Flow PC0 | uint16 | l/min | false | DEVICE_DATA | 80 | 1 | 1/10 | +| pc0flow | Flow PC0 | uint16 | l/h | false | DEVICE_DATA | 81 | 1 | 1 | +| pc1flow | Flow PC1 | uint16 | l/h | false | DEVICE_DATA | 82 | 1 | 1 | +| pc1on | PC1 | boolean | | false | DEVICE_DATA | 83 | 1 | 1 | +| pc1rate | PC1 rate | uint8 | % | false | DEVICE_DATA | 84 | 1 | 1 | uint8 -| pumpkickhour | pump kick hour | uint8 (>=0<=23) | hours | true | DEVICE_DATA | 84 | 1 | 1 | -| pumpkickday | pump kick day | enum | | true | DEVICE_DATA | 85 | 1 | 1 | +| pumpkickhour | pump kick hour | uint8 (>=0<=23) | hours | true | DEVICE_DATA | 85 | 1 | 1 | +| pumpkickday | pump kick day | enum | | true | DEVICE_DATA | 86 | 1 | 1 | uint16 -| pumpkickdelay | pump kick delay | uint16 (>=0<=32767) | minutes | true | DEVICE_DATA | 86 | 1 | 1 | -| meterheat | meter heating | uint24 | kWh | false | DEVICE_DATA | 100 | 2 | 1/10 | +| pumpkickdelay | pump kick delay | uint16 (>=0<=32767) | minutes | true | DEVICE_DATA | 87 | 1 | 1 | +| meterheat | meter heating | uint24 | kWh | false | DEVICE_DATA | 101 | 2 | 1/10 | | dhw.meter | meter | uint24 | kWh | false | DHW | 2 | 2 | 1/10 | -| gasmeterheat | gas meter heating | uint24 | kWh | false | DEVICE_DATA | 275 | 2 | 1/10 | +| gasmeterheat | gas meter heating | uint24 | kWh | false | DEVICE_DATA | 276 | 2 | 1/10 | | dhw.gasmeter | gas meter | uint24 | kWh | false | DHW | 71 | 2 | 1/10 | -| nrgheat2 | energy heating 2 | uint24 | kWh | false | DEVICE_DATA | 277 | 2 | 1/10 | +| nrgheat2 | energy heating 2 | uint24 | kWh | false | DEVICE_DATA | 278 | 2 | 1/10 | | dhw.nrg2 | energy 2 | uint24 | kWh | false | DHW | 73 | 2 | 1/10 | | dhw.tapactivated | turn on/off | boolean | | true | DHW | 28 | 1 | 1 | | dhw.settemp | set temperature | uint8 | C | false | DHW | 29 | 1 | 1 | @@ -4347,10 +4372,10 @@ uint8 | dhw.starts | starts | uint24 | | false | DHW | 67 | 2 | 1 | | dhw.workm | active time | time | minutes | false | DHW | 69 | 2 | 1 | uint8 -| nompower | nominal Power | uint8 (>=0<=0) | kW | true | DEVICE_DATA | 279 | 1 | 1 | -| nrgtotal | total energy | uint24 | kWh | false | DEVICE_DATA | 88 | 2 | 1/100 | +| nompower | nominal Power | uint8 (>=0<=0) | kW | true | DEVICE_DATA | 280 | 1 | 1 | +| nrgtotal | total energy | uint24 | kWh | false | DEVICE_DATA | 89 | 2 | 1/100 | uint24 -| nrgheat | energy heating | uint24 (>=0<=10000000) | kWh | true | DEVICE_DATA | 90 | 2 | 1/100 | +| nrgheat | energy heating | uint24 (>=0<=10000000) | kWh | true | DEVICE_DATA | 91 | 2 | 1/100 | uint24 | dhw.nrg | energy | uint24 (>=0<=10000000) | kWh | true | DHW | 0 | 2 | 1/100 | @@ -4373,39 +4398,39 @@ uint8 | syspress | system pressure | uint8 | bar | false | DEVICE_DATA | 11 | 1 | 1/10 | | boiltemp | actual boiler temperature | uint16 | C | false | DEVICE_DATA | 12 | 1 | 1/10 | | headertemp | low loss header | uint16 | C | false | DEVICE_DATA | 13 | 1 | 1/10 | -| exhausttemp | exhaust temperature | uint16 | C | false | DEVICE_DATA | 253 | 1 | 1/10 | -| burngas | gas | boolean | | false | DEVICE_DATA | 254 | 1 | 1 | -| burngas2 | gas stage 2 | boolean | | false | DEVICE_DATA | 255 | 1 | 1 | -| flamecurr | flame current | uint16 | µA | false | DEVICE_DATA | 256 | 1 | 1/10 | -| fanwork | fan | boolean | | false | DEVICE_DATA | 257 | 1 | 1 | -| ignwork | ignition | boolean | | false | DEVICE_DATA | 258 | 1 | 1 | -| oilpreheat | oil preheating | boolean | | false | DEVICE_DATA | 259 | 1 | 1 | +| exhausttemp | exhaust temperature | uint16 | C | false | DEVICE_DATA | 254 | 1 | 1/10 | +| burngas | gas | boolean | | false | DEVICE_DATA | 255 | 1 | 1 | +| burngas2 | gas stage 2 | boolean | | false | DEVICE_DATA | 256 | 1 | 1 | +| flamecurr | flame current | uint16 | µA | false | DEVICE_DATA | 257 | 1 | 1/10 | +| fanwork | fan | boolean | | false | DEVICE_DATA | 258 | 1 | 1 | +| ignwork | ignition | boolean | | false | DEVICE_DATA | 259 | 1 | 1 | +| oilpreheat | oil preheating | boolean | | false | DEVICE_DATA | 260 | 1 | 1 | uint8 -| burnminpower | burner min power | uint8 (>=0<=0) | % | true | DEVICE_DATA | 260 | 1 | 1 | +| burnminpower | burner min power | uint8 (>=0<=0) | % | true | DEVICE_DATA | 261 | 1 | 1 | uint8 -| burnmaxpower | burner max power | uint8 (>=0<=254) | % | true | DEVICE_DATA | 261 | 1 | 1 | +| burnmaxpower | burner max power | uint8 (>=0<=254) | % | true | DEVICE_DATA | 262 | 1 | 1 | uint8 -| burnminperiod | burner min period | uint8 (>=0<=120) | minutes | true | DEVICE_DATA | 262 | 1 | 1 | -| absburnpow | burner current power (absolute) | uint8 | % | false | DEVICE_DATA | 263 | 1 | 1 | -| heatblock | Heatblock temperature | uint16 | C | false | DEVICE_DATA | 264 | 1 | 1/10 | +| burnminperiod | burner min period | uint8 (>=0<=120) | minutes | true | DEVICE_DATA | 263 | 1 | 1 | +| absburnpow | burner current power (absolute) | uint8 | % | false | DEVICE_DATA | 264 | 1 | 1 | +| heatblock | Heatblock temperature | uint16 | C | false | DEVICE_DATA | 265 | 1 | 1/10 | int8 -| boilhyston | hysteresis on temperature | int8 (>=-20<=0) | C | true | DEVICE_DATA | 265 | 1 | 1 | +| boilhyston | hysteresis on temperature | int8 (>=-20<=0) | C | true | DEVICE_DATA | 266 | 1 | 1 | int8 -| boilhystoff | hysteresis off temperature | int8 (>=0<=20) | C | true | DEVICE_DATA | 266 | 1 | 1 | +| boilhystoff | hysteresis off temperature | int8 (>=0<=20) | C | true | DEVICE_DATA | 267 | 1 | 1 | int8 -| boil2hyston | hysteresis stage 2 on temperature | int8 (>=-20<=0) | C | true | DEVICE_DATA | 267 | 1 | 1 | +| boil2hyston | hysteresis stage 2 on temperature | int8 (>=-20<=0) | C | true | DEVICE_DATA | 268 | 1 | 1 | int8 -| boil2hystoff | hysteresis stage 2 off temperature | int8 (>=0<=20) | C | true | DEVICE_DATA | 268 | 1 | 1 | -| curveon | heatingcurve on | boolean | | true | DEVICE_DATA | 269 | 1 | 1 | +| boil2hystoff | hysteresis stage 2 off temperature | int8 (>=0<=20) | C | true | DEVICE_DATA | 269 | 1 | 1 | +| curveon | heatingcurve on | boolean | | true | DEVICE_DATA | 270 | 1 | 1 | uint8 -| curvebase | heatingcurve base | uint8 (>=20<=90) | C | true | DEVICE_DATA | 270 | 1 | 1 | +| curvebase | heatingcurve base | uint8 (>=20<=90) | C | true | DEVICE_DATA | 271 | 1 | 1 | uint8 -| curveend | heatingcurve end | uint8 (>=20<=90) | C | true | DEVICE_DATA | 271 | 1 | 1 | +| curveend | heatingcurve end | uint8 (>=20<=90) | C | true | DEVICE_DATA | 272 | 1 | 1 | uint8 -| summertemp | summer temperature | uint8 (>=0<=45) | C | true | DEVICE_DATA | 272 | 1 | 1 | -| nofrostmode | nofrost mode | boolean | | true | DEVICE_DATA | 273 | 1 | 1 | +| summertemp | summer temperature | uint8 (>=0<=45) | C | true | DEVICE_DATA | 273 | 1 | 1 | +| nofrostmode | nofrost mode | boolean | | true | DEVICE_DATA | 274 | 1 | 1 | uint8 -| nofrosttemp | nofrost temperature | uint8 (>=0<=10) | C | true | DEVICE_DATA | 274 | 1 | 1 | +| nofrosttemp | nofrost temperature | uint8 (>=0<=10) | C | true | DEVICE_DATA | 275 | 1 | 1 | | heatingactivated | heating activated | boolean | | true | DEVICE_DATA | 14 | 1 | 1 | uint8 | heatingtemp | heating temperature | uint8 (>=0<=90) | C | true | DEVICE_DATA | 15 | 1 | 1 | @@ -4440,20 +4465,21 @@ uint16 | emergencyops | emergency operation | boolean | | true | DEVICE_DATA | 78 | 1 | 1 | uint8 | emergencytemp | emergency temperature | uint8 (>=15<=70) | C | true | DEVICE_DATA | 79 | 1 | 1 | -| pc0flow | Flow PC0 | int16 | l/h | false | DEVICE_DATA | 80 | 1 | 1 | -| pc1flow | Flow PC1 | int16 | l/h | false | DEVICE_DATA | 81 | 1 | 1 | -| pc1on | PC1 | boolean | | false | DEVICE_DATA | 82 | 1 | 1 | -| pc1rate | PC1 rate | uint8 | % | false | DEVICE_DATA | 83 | 1 | 1 | +| pc0lpm | Flow PC0 | uint16 | l/min | false | DEVICE_DATA | 80 | 1 | 1/10 | +| pc0flow | Flow PC0 | uint16 | l/h | false | DEVICE_DATA | 81 | 1 | 1 | +| pc1flow | Flow PC1 | uint16 | l/h | false | DEVICE_DATA | 82 | 1 | 1 | +| pc1on | PC1 | boolean | | false | DEVICE_DATA | 83 | 1 | 1 | +| pc1rate | PC1 rate | uint8 | % | false | DEVICE_DATA | 84 | 1 | 1 | uint8 -| pumpkickhour | pump kick hour | uint8 (>=0<=23) | hours | true | DEVICE_DATA | 84 | 1 | 1 | -| pumpkickday | pump kick day | enum | | true | DEVICE_DATA | 85 | 1 | 1 | +| pumpkickhour | pump kick hour | uint8 (>=0<=23) | hours | true | DEVICE_DATA | 85 | 1 | 1 | +| pumpkickday | pump kick day | enum | | true | DEVICE_DATA | 86 | 1 | 1 | uint16 -| pumpkickdelay | pump kick delay | uint16 (>=0<=32767) | minutes | true | DEVICE_DATA | 86 | 1 | 1 | -| meterheat | meter heating | uint24 | kWh | false | DEVICE_DATA | 100 | 2 | 1/10 | +| pumpkickdelay | pump kick delay | uint16 (>=0<=32767) | minutes | true | DEVICE_DATA | 87 | 1 | 1 | +| meterheat | meter heating | uint24 | kWh | false | DEVICE_DATA | 101 | 2 | 1/10 | | dhw.meter | meter | uint24 | kWh | false | DHW | 2 | 2 | 1/10 | -| gasmeterheat | gas meter heating | uint24 | kWh | false | DEVICE_DATA | 275 | 2 | 1/10 | +| gasmeterheat | gas meter heating | uint24 | kWh | false | DEVICE_DATA | 276 | 2 | 1/10 | | dhw.gasmeter | gas meter | uint24 | kWh | false | DHW | 71 | 2 | 1/10 | -| nrgheat2 | energy heating 2 | uint24 | kWh | false | DEVICE_DATA | 277 | 2 | 1/10 | +| nrgheat2 | energy heating 2 | uint24 | kWh | false | DEVICE_DATA | 278 | 2 | 1/10 | | dhw.nrg2 | energy 2 | uint24 | kWh | false | DHW | 73 | 2 | 1/10 | | dhw.tapactivated | turn on/off | boolean | | true | DHW | 28 | 1 | 1 | | dhw.settemp | set temperature | uint8 | C | false | DHW | 29 | 1 | 1 | @@ -4507,10 +4533,10 @@ uint8 | dhw.starts | starts | uint24 | | false | DHW | 67 | 2 | 1 | | dhw.workm | active time | time | minutes | false | DHW | 69 | 2 | 1 | uint8 -| nompower | nominal Power | uint8 (>=0<=0) | kW | true | DEVICE_DATA | 279 | 1 | 1 | -| nrgtotal | total energy | uint24 | kWh | false | DEVICE_DATA | 88 | 2 | 1/100 | +| nompower | nominal Power | uint8 (>=0<=0) | kW | true | DEVICE_DATA | 280 | 1 | 1 | +| nrgtotal | total energy | uint24 | kWh | false | DEVICE_DATA | 89 | 2 | 1/100 | uint24 -| nrgheat | energy heating | uint24 (>=0<=10000000) | kWh | true | DEVICE_DATA | 90 | 2 | 1/100 | +| nrgheat | energy heating | uint24 (>=0<=10000000) | kWh | true | DEVICE_DATA | 91 | 2 | 1/100 | uint24 | dhw.nrg | energy | uint24 (>=0<=10000000) | kWh | true | DHW | 0 | 2 | 1/100 | @@ -4533,39 +4559,39 @@ uint8 | syspress | system pressure | uint8 | bar | false | DEVICE_DATA | 11 | 1 | 1/10 | | boiltemp | actual boiler temperature | uint16 | C | false | DEVICE_DATA | 12 | 1 | 1/10 | | headertemp | low loss header | uint16 | C | false | DEVICE_DATA | 13 | 1 | 1/10 | -| exhausttemp | exhaust temperature | uint16 | C | false | DEVICE_DATA | 253 | 1 | 1/10 | -| burngas | gas | boolean | | false | DEVICE_DATA | 254 | 1 | 1 | -| burngas2 | gas stage 2 | boolean | | false | DEVICE_DATA | 255 | 1 | 1 | -| flamecurr | flame current | uint16 | µA | false | DEVICE_DATA | 256 | 1 | 1/10 | -| fanwork | fan | boolean | | false | DEVICE_DATA | 257 | 1 | 1 | -| ignwork | ignition | boolean | | false | DEVICE_DATA | 258 | 1 | 1 | -| oilpreheat | oil preheating | boolean | | false | DEVICE_DATA | 259 | 1 | 1 | +| exhausttemp | exhaust temperature | uint16 | C | false | DEVICE_DATA | 254 | 1 | 1/10 | +| burngas | gas | boolean | | false | DEVICE_DATA | 255 | 1 | 1 | +| burngas2 | gas stage 2 | boolean | | false | DEVICE_DATA | 256 | 1 | 1 | +| flamecurr | flame current | uint16 | µA | false | DEVICE_DATA | 257 | 1 | 1/10 | +| fanwork | fan | boolean | | false | DEVICE_DATA | 258 | 1 | 1 | +| ignwork | ignition | boolean | | false | DEVICE_DATA | 259 | 1 | 1 | +| oilpreheat | oil preheating | boolean | | false | DEVICE_DATA | 260 | 1 | 1 | uint8 -| burnminpower | burner min power | uint8 (>=0<=0) | % | true | DEVICE_DATA | 260 | 1 | 1 | +| burnminpower | burner min power | uint8 (>=0<=0) | % | true | DEVICE_DATA | 261 | 1 | 1 | uint8 -| burnmaxpower | burner max power | uint8 (>=0<=254) | % | true | DEVICE_DATA | 261 | 1 | 1 | +| burnmaxpower | burner max power | uint8 (>=0<=254) | % | true | DEVICE_DATA | 262 | 1 | 1 | uint8 -| burnminperiod | burner min period | uint8 (>=0<=120) | minutes | true | DEVICE_DATA | 262 | 1 | 1 | -| absburnpow | burner current power (absolute) | uint8 | % | false | DEVICE_DATA | 263 | 1 | 1 | -| heatblock | Heatblock temperature | uint16 | C | false | DEVICE_DATA | 264 | 1 | 1/10 | +| burnminperiod | burner min period | uint8 (>=0<=120) | minutes | true | DEVICE_DATA | 263 | 1 | 1 | +| absburnpow | burner current power (absolute) | uint8 | % | false | DEVICE_DATA | 264 | 1 | 1 | +| heatblock | Heatblock temperature | uint16 | C | false | DEVICE_DATA | 265 | 1 | 1/10 | int8 -| boilhyston | hysteresis on temperature | int8 (>=-20<=0) | C | true | DEVICE_DATA | 265 | 1 | 1 | +| boilhyston | hysteresis on temperature | int8 (>=-20<=0) | C | true | DEVICE_DATA | 266 | 1 | 1 | int8 -| boilhystoff | hysteresis off temperature | int8 (>=0<=20) | C | true | DEVICE_DATA | 266 | 1 | 1 | +| boilhystoff | hysteresis off temperature | int8 (>=0<=20) | C | true | DEVICE_DATA | 267 | 1 | 1 | int8 -| boil2hyston | hysteresis stage 2 on temperature | int8 (>=-20<=0) | C | true | DEVICE_DATA | 267 | 1 | 1 | +| boil2hyston | hysteresis stage 2 on temperature | int8 (>=-20<=0) | C | true | DEVICE_DATA | 268 | 1 | 1 | int8 -| boil2hystoff | hysteresis stage 2 off temperature | int8 (>=0<=20) | C | true | DEVICE_DATA | 268 | 1 | 1 | -| curveon | heatingcurve on | boolean | | true | DEVICE_DATA | 269 | 1 | 1 | +| boil2hystoff | hysteresis stage 2 off temperature | int8 (>=0<=20) | C | true | DEVICE_DATA | 269 | 1 | 1 | +| curveon | heatingcurve on | boolean | | true | DEVICE_DATA | 270 | 1 | 1 | uint8 -| curvebase | heatingcurve base | uint8 (>=20<=90) | C | true | DEVICE_DATA | 270 | 1 | 1 | +| curvebase | heatingcurve base | uint8 (>=20<=90) | C | true | DEVICE_DATA | 271 | 1 | 1 | uint8 -| curveend | heatingcurve end | uint8 (>=20<=90) | C | true | DEVICE_DATA | 271 | 1 | 1 | +| curveend | heatingcurve end | uint8 (>=20<=90) | C | true | DEVICE_DATA | 272 | 1 | 1 | uint8 -| summertemp | summer temperature | uint8 (>=0<=45) | C | true | DEVICE_DATA | 272 | 1 | 1 | -| nofrostmode | nofrost mode | boolean | | true | DEVICE_DATA | 273 | 1 | 1 | +| summertemp | summer temperature | uint8 (>=0<=45) | C | true | DEVICE_DATA | 273 | 1 | 1 | +| nofrostmode | nofrost mode | boolean | | true | DEVICE_DATA | 274 | 1 | 1 | uint8 -| nofrosttemp | nofrost temperature | uint8 (>=0<=10) | C | true | DEVICE_DATA | 274 | 1 | 1 | +| nofrosttemp | nofrost temperature | uint8 (>=0<=10) | C | true | DEVICE_DATA | 275 | 1 | 1 | | heatingactivated | heating activated | boolean | | true | DEVICE_DATA | 14 | 1 | 1 | uint8 | heatingtemp | heating temperature | uint8 (>=0<=90) | C | true | DEVICE_DATA | 15 | 1 | 1 | @@ -4600,20 +4626,21 @@ uint16 | emergencyops | emergency operation | boolean | | true | DEVICE_DATA | 78 | 1 | 1 | uint8 | emergencytemp | emergency temperature | uint8 (>=15<=70) | C | true | DEVICE_DATA | 79 | 1 | 1 | -| pc0flow | Flow PC0 | int16 | l/h | false | DEVICE_DATA | 80 | 1 | 1 | -| pc1flow | Flow PC1 | int16 | l/h | false | DEVICE_DATA | 81 | 1 | 1 | -| pc1on | PC1 | boolean | | false | DEVICE_DATA | 82 | 1 | 1 | -| pc1rate | PC1 rate | uint8 | % | false | DEVICE_DATA | 83 | 1 | 1 | +| pc0lpm | Flow PC0 | uint16 | l/min | false | DEVICE_DATA | 80 | 1 | 1/10 | +| pc0flow | Flow PC0 | uint16 | l/h | false | DEVICE_DATA | 81 | 1 | 1 | +| pc1flow | Flow PC1 | uint16 | l/h | false | DEVICE_DATA | 82 | 1 | 1 | +| pc1on | PC1 | boolean | | false | DEVICE_DATA | 83 | 1 | 1 | +| pc1rate | PC1 rate | uint8 | % | false | DEVICE_DATA | 84 | 1 | 1 | uint8 -| pumpkickhour | pump kick hour | uint8 (>=0<=23) | hours | true | DEVICE_DATA | 84 | 1 | 1 | -| pumpkickday | pump kick day | enum | | true | DEVICE_DATA | 85 | 1 | 1 | +| pumpkickhour | pump kick hour | uint8 (>=0<=23) | hours | true | DEVICE_DATA | 85 | 1 | 1 | +| pumpkickday | pump kick day | enum | | true | DEVICE_DATA | 86 | 1 | 1 | uint16 -| pumpkickdelay | pump kick delay | uint16 (>=0<=32767) | minutes | true | DEVICE_DATA | 86 | 1 | 1 | -| meterheat | meter heating | uint24 | kWh | false | DEVICE_DATA | 100 | 2 | 1/10 | +| pumpkickdelay | pump kick delay | uint16 (>=0<=32767) | minutes | true | DEVICE_DATA | 87 | 1 | 1 | +| meterheat | meter heating | uint24 | kWh | false | DEVICE_DATA | 101 | 2 | 1/10 | | dhw.meter | meter | uint24 | kWh | false | DHW | 2 | 2 | 1/10 | -| gasmeterheat | gas meter heating | uint24 | kWh | false | DEVICE_DATA | 275 | 2 | 1/10 | +| gasmeterheat | gas meter heating | uint24 | kWh | false | DEVICE_DATA | 276 | 2 | 1/10 | | dhw.gasmeter | gas meter | uint24 | kWh | false | DHW | 71 | 2 | 1/10 | -| nrgheat2 | energy heating 2 | uint24 | kWh | false | DEVICE_DATA | 277 | 2 | 1/10 | +| nrgheat2 | energy heating 2 | uint24 | kWh | false | DEVICE_DATA | 278 | 2 | 1/10 | | dhw.nrg2 | energy 2 | uint24 | kWh | false | DHW | 73 | 2 | 1/10 | | dhw.tapactivated | turn on/off | boolean | | true | DHW | 28 | 1 | 1 | | dhw.settemp | set temperature | uint8 | C | false | DHW | 29 | 1 | 1 | @@ -4667,10 +4694,10 @@ uint8 | dhw.starts | starts | uint24 | | false | DHW | 67 | 2 | 1 | | dhw.workm | active time | time | minutes | false | DHW | 69 | 2 | 1 | uint8 -| nompower | nominal Power | uint8 (>=0<=0) | kW | true | DEVICE_DATA | 279 | 1 | 1 | -| nrgtotal | total energy | uint24 | kWh | false | DEVICE_DATA | 88 | 2 | 1/100 | +| nompower | nominal Power | uint8 (>=0<=0) | kW | true | DEVICE_DATA | 280 | 1 | 1 | +| nrgtotal | total energy | uint24 | kWh | false | DEVICE_DATA | 89 | 2 | 1/100 | uint24 -| nrgheat | energy heating | uint24 (>=0<=10000000) | kWh | true | DEVICE_DATA | 90 | 2 | 1/100 | +| nrgheat | energy heating | uint24 (>=0<=10000000) | kWh | true | DEVICE_DATA | 91 | 2 | 1/100 | uint24 | dhw.nrg | energy | uint24 (>=0<=10000000) | kWh | true | DHW | 0 | 2 | 1/100 | @@ -4693,39 +4720,39 @@ uint8 | syspress | system pressure | uint8 | bar | false | DEVICE_DATA | 11 | 1 | 1/10 | | boiltemp | actual boiler temperature | uint16 | C | false | DEVICE_DATA | 12 | 1 | 1/10 | | headertemp | low loss header | uint16 | C | false | DEVICE_DATA | 13 | 1 | 1/10 | -| exhausttemp | exhaust temperature | uint16 | C | false | DEVICE_DATA | 253 | 1 | 1/10 | -| burngas | gas | boolean | | false | DEVICE_DATA | 254 | 1 | 1 | -| burngas2 | gas stage 2 | boolean | | false | DEVICE_DATA | 255 | 1 | 1 | -| flamecurr | flame current | uint16 | µA | false | DEVICE_DATA | 256 | 1 | 1/10 | -| fanwork | fan | boolean | | false | DEVICE_DATA | 257 | 1 | 1 | -| ignwork | ignition | boolean | | false | DEVICE_DATA | 258 | 1 | 1 | -| oilpreheat | oil preheating | boolean | | false | DEVICE_DATA | 259 | 1 | 1 | +| exhausttemp | exhaust temperature | uint16 | C | false | DEVICE_DATA | 254 | 1 | 1/10 | +| burngas | gas | boolean | | false | DEVICE_DATA | 255 | 1 | 1 | +| burngas2 | gas stage 2 | boolean | | false | DEVICE_DATA | 256 | 1 | 1 | +| flamecurr | flame current | uint16 | µA | false | DEVICE_DATA | 257 | 1 | 1/10 | +| fanwork | fan | boolean | | false | DEVICE_DATA | 258 | 1 | 1 | +| ignwork | ignition | boolean | | false | DEVICE_DATA | 259 | 1 | 1 | +| oilpreheat | oil preheating | boolean | | false | DEVICE_DATA | 260 | 1 | 1 | uint8 -| burnminpower | burner min power | uint8 (>=0<=0) | % | true | DEVICE_DATA | 260 | 1 | 1 | +| burnminpower | burner min power | uint8 (>=0<=0) | % | true | DEVICE_DATA | 261 | 1 | 1 | uint8 -| burnmaxpower | burner max power | uint8 (>=0<=254) | % | true | DEVICE_DATA | 261 | 1 | 1 | +| burnmaxpower | burner max power | uint8 (>=0<=254) | % | true | DEVICE_DATA | 262 | 1 | 1 | uint8 -| burnminperiod | burner min period | uint8 (>=0<=120) | minutes | true | DEVICE_DATA | 262 | 1 | 1 | -| absburnpow | burner current power (absolute) | uint8 | % | false | DEVICE_DATA | 263 | 1 | 1 | -| heatblock | Heatblock temperature | uint16 | C | false | DEVICE_DATA | 264 | 1 | 1/10 | +| burnminperiod | burner min period | uint8 (>=0<=120) | minutes | true | DEVICE_DATA | 263 | 1 | 1 | +| absburnpow | burner current power (absolute) | uint8 | % | false | DEVICE_DATA | 264 | 1 | 1 | +| heatblock | Heatblock temperature | uint16 | C | false | DEVICE_DATA | 265 | 1 | 1/10 | int8 -| boilhyston | hysteresis on temperature | int8 (>=-20<=0) | C | true | DEVICE_DATA | 265 | 1 | 1 | +| boilhyston | hysteresis on temperature | int8 (>=-20<=0) | C | true | DEVICE_DATA | 266 | 1 | 1 | int8 -| boilhystoff | hysteresis off temperature | int8 (>=0<=20) | C | true | DEVICE_DATA | 266 | 1 | 1 | +| boilhystoff | hysteresis off temperature | int8 (>=0<=20) | C | true | DEVICE_DATA | 267 | 1 | 1 | int8 -| boil2hyston | hysteresis stage 2 on temperature | int8 (>=-20<=0) | C | true | DEVICE_DATA | 267 | 1 | 1 | +| boil2hyston | hysteresis stage 2 on temperature | int8 (>=-20<=0) | C | true | DEVICE_DATA | 268 | 1 | 1 | int8 -| boil2hystoff | hysteresis stage 2 off temperature | int8 (>=0<=20) | C | true | DEVICE_DATA | 268 | 1 | 1 | -| curveon | heatingcurve on | boolean | | true | DEVICE_DATA | 269 | 1 | 1 | +| boil2hystoff | hysteresis stage 2 off temperature | int8 (>=0<=20) | C | true | DEVICE_DATA | 269 | 1 | 1 | +| curveon | heatingcurve on | boolean | | true | DEVICE_DATA | 270 | 1 | 1 | uint8 -| curvebase | heatingcurve base | uint8 (>=20<=90) | C | true | DEVICE_DATA | 270 | 1 | 1 | +| curvebase | heatingcurve base | uint8 (>=20<=90) | C | true | DEVICE_DATA | 271 | 1 | 1 | uint8 -| curveend | heatingcurve end | uint8 (>=20<=90) | C | true | DEVICE_DATA | 271 | 1 | 1 | +| curveend | heatingcurve end | uint8 (>=20<=90) | C | true | DEVICE_DATA | 272 | 1 | 1 | uint8 -| summertemp | summer temperature | uint8 (>=0<=45) | C | true | DEVICE_DATA | 272 | 1 | 1 | -| nofrostmode | nofrost mode | boolean | | true | DEVICE_DATA | 273 | 1 | 1 | +| summertemp | summer temperature | uint8 (>=0<=45) | C | true | DEVICE_DATA | 273 | 1 | 1 | +| nofrostmode | nofrost mode | boolean | | true | DEVICE_DATA | 274 | 1 | 1 | uint8 -| nofrosttemp | nofrost temperature | uint8 (>=0<=10) | C | true | DEVICE_DATA | 274 | 1 | 1 | +| nofrosttemp | nofrost temperature | uint8 (>=0<=10) | C | true | DEVICE_DATA | 275 | 1 | 1 | | heatingactivated | heating activated | boolean | | true | DEVICE_DATA | 14 | 1 | 1 | uint8 | heatingtemp | heating temperature | uint8 (>=0<=90) | C | true | DEVICE_DATA | 15 | 1 | 1 | @@ -4760,20 +4787,21 @@ uint16 | emergencyops | emergency operation | boolean | | true | DEVICE_DATA | 78 | 1 | 1 | uint8 | emergencytemp | emergency temperature | uint8 (>=15<=70) | C | true | DEVICE_DATA | 79 | 1 | 1 | -| pc0flow | Flow PC0 | int16 | l/h | false | DEVICE_DATA | 80 | 1 | 1 | -| pc1flow | Flow PC1 | int16 | l/h | false | DEVICE_DATA | 81 | 1 | 1 | -| pc1on | PC1 | boolean | | false | DEVICE_DATA | 82 | 1 | 1 | -| pc1rate | PC1 rate | uint8 | % | false | DEVICE_DATA | 83 | 1 | 1 | +| pc0lpm | Flow PC0 | uint16 | l/min | false | DEVICE_DATA | 80 | 1 | 1/10 | +| pc0flow | Flow PC0 | uint16 | l/h | false | DEVICE_DATA | 81 | 1 | 1 | +| pc1flow | Flow PC1 | uint16 | l/h | false | DEVICE_DATA | 82 | 1 | 1 | +| pc1on | PC1 | boolean | | false | DEVICE_DATA | 83 | 1 | 1 | +| pc1rate | PC1 rate | uint8 | % | false | DEVICE_DATA | 84 | 1 | 1 | uint8 -| pumpkickhour | pump kick hour | uint8 (>=0<=23) | hours | true | DEVICE_DATA | 84 | 1 | 1 | -| pumpkickday | pump kick day | enum | | true | DEVICE_DATA | 85 | 1 | 1 | +| pumpkickhour | pump kick hour | uint8 (>=0<=23) | hours | true | DEVICE_DATA | 85 | 1 | 1 | +| pumpkickday | pump kick day | enum | | true | DEVICE_DATA | 86 | 1 | 1 | uint16 -| pumpkickdelay | pump kick delay | uint16 (>=0<=32767) | minutes | true | DEVICE_DATA | 86 | 1 | 1 | -| meterheat | meter heating | uint24 | kWh | false | DEVICE_DATA | 100 | 2 | 1/10 | +| pumpkickdelay | pump kick delay | uint16 (>=0<=32767) | minutes | true | DEVICE_DATA | 87 | 1 | 1 | +| meterheat | meter heating | uint24 | kWh | false | DEVICE_DATA | 101 | 2 | 1/10 | | dhw.meter | meter | uint24 | kWh | false | DHW | 2 | 2 | 1/10 | -| gasmeterheat | gas meter heating | uint24 | kWh | false | DEVICE_DATA | 275 | 2 | 1/10 | +| gasmeterheat | gas meter heating | uint24 | kWh | false | DEVICE_DATA | 276 | 2 | 1/10 | | dhw.gasmeter | gas meter | uint24 | kWh | false | DHW | 71 | 2 | 1/10 | -| nrgheat2 | energy heating 2 | uint24 | kWh | false | DEVICE_DATA | 277 | 2 | 1/10 | +| nrgheat2 | energy heating 2 | uint24 | kWh | false | DEVICE_DATA | 278 | 2 | 1/10 | | dhw.nrg2 | energy 2 | uint24 | kWh | false | DHW | 73 | 2 | 1/10 | | dhw.tapactivated | turn on/off | boolean | | true | DHW | 28 | 1 | 1 | | dhw.settemp | set temperature | uint8 | C | false | DHW | 29 | 1 | 1 | @@ -4827,10 +4855,10 @@ uint8 | dhw.starts | starts | uint24 | | false | DHW | 67 | 2 | 1 | | dhw.workm | active time | time | minutes | false | DHW | 69 | 2 | 1 | uint8 -| nompower | nominal Power | uint8 (>=0<=0) | kW | true | DEVICE_DATA | 279 | 1 | 1 | -| nrgtotal | total energy | uint24 | kWh | false | DEVICE_DATA | 88 | 2 | 1/100 | +| nompower | nominal Power | uint8 (>=0<=0) | kW | true | DEVICE_DATA | 280 | 1 | 1 | +| nrgtotal | total energy | uint24 | kWh | false | DEVICE_DATA | 89 | 2 | 1/100 | uint24 -| nrgheat | energy heating | uint24 (>=0<=10000000) | kWh | true | DEVICE_DATA | 90 | 2 | 1/100 | +| nrgheat | energy heating | uint24 (>=0<=10000000) | kWh | true | DEVICE_DATA | 91 | 2 | 1/100 | uint24 | dhw.nrg | energy | uint24 (>=0<=10000000) | kWh | true | DHW | 0 | 2 | 1/100 | @@ -4853,39 +4881,39 @@ uint8 | syspress | system pressure | uint8 | bar | false | DEVICE_DATA | 11 | 1 | 1/10 | | boiltemp | actual boiler temperature | uint16 | C | false | DEVICE_DATA | 12 | 1 | 1/10 | | headertemp | low loss header | uint16 | C | false | DEVICE_DATA | 13 | 1 | 1/10 | -| exhausttemp | exhaust temperature | uint16 | C | false | DEVICE_DATA | 253 | 1 | 1/10 | -| burngas | gas | boolean | | false | DEVICE_DATA | 254 | 1 | 1 | -| burngas2 | gas stage 2 | boolean | | false | DEVICE_DATA | 255 | 1 | 1 | -| flamecurr | flame current | uint16 | µA | false | DEVICE_DATA | 256 | 1 | 1/10 | -| fanwork | fan | boolean | | false | DEVICE_DATA | 257 | 1 | 1 | -| ignwork | ignition | boolean | | false | DEVICE_DATA | 258 | 1 | 1 | -| oilpreheat | oil preheating | boolean | | false | DEVICE_DATA | 259 | 1 | 1 | +| exhausttemp | exhaust temperature | uint16 | C | false | DEVICE_DATA | 254 | 1 | 1/10 | +| burngas | gas | boolean | | false | DEVICE_DATA | 255 | 1 | 1 | +| burngas2 | gas stage 2 | boolean | | false | DEVICE_DATA | 256 | 1 | 1 | +| flamecurr | flame current | uint16 | µA | false | DEVICE_DATA | 257 | 1 | 1/10 | +| fanwork | fan | boolean | | false | DEVICE_DATA | 258 | 1 | 1 | +| ignwork | ignition | boolean | | false | DEVICE_DATA | 259 | 1 | 1 | +| oilpreheat | oil preheating | boolean | | false | DEVICE_DATA | 260 | 1 | 1 | uint8 -| burnminpower | burner min power | uint8 (>=0<=0) | % | true | DEVICE_DATA | 260 | 1 | 1 | +| burnminpower | burner min power | uint8 (>=0<=0) | % | true | DEVICE_DATA | 261 | 1 | 1 | uint8 -| burnmaxpower | burner max power | uint8 (>=0<=254) | % | true | DEVICE_DATA | 261 | 1 | 1 | +| burnmaxpower | burner max power | uint8 (>=0<=254) | % | true | DEVICE_DATA | 262 | 1 | 1 | uint8 -| burnminperiod | burner min period | uint8 (>=0<=120) | minutes | true | DEVICE_DATA | 262 | 1 | 1 | -| absburnpow | burner current power (absolute) | uint8 | % | false | DEVICE_DATA | 263 | 1 | 1 | -| heatblock | Heatblock temperature | uint16 | C | false | DEVICE_DATA | 264 | 1 | 1/10 | +| burnminperiod | burner min period | uint8 (>=0<=120) | minutes | true | DEVICE_DATA | 263 | 1 | 1 | +| absburnpow | burner current power (absolute) | uint8 | % | false | DEVICE_DATA | 264 | 1 | 1 | +| heatblock | Heatblock temperature | uint16 | C | false | DEVICE_DATA | 265 | 1 | 1/10 | int8 -| boilhyston | hysteresis on temperature | int8 (>=-20<=0) | C | true | DEVICE_DATA | 265 | 1 | 1 | +| boilhyston | hysteresis on temperature | int8 (>=-20<=0) | C | true | DEVICE_DATA | 266 | 1 | 1 | int8 -| boilhystoff | hysteresis off temperature | int8 (>=0<=20) | C | true | DEVICE_DATA | 266 | 1 | 1 | +| boilhystoff | hysteresis off temperature | int8 (>=0<=20) | C | true | DEVICE_DATA | 267 | 1 | 1 | int8 -| boil2hyston | hysteresis stage 2 on temperature | int8 (>=-20<=0) | C | true | DEVICE_DATA | 267 | 1 | 1 | +| boil2hyston | hysteresis stage 2 on temperature | int8 (>=-20<=0) | C | true | DEVICE_DATA | 268 | 1 | 1 | int8 -| boil2hystoff | hysteresis stage 2 off temperature | int8 (>=0<=20) | C | true | DEVICE_DATA | 268 | 1 | 1 | -| curveon | heatingcurve on | boolean | | true | DEVICE_DATA | 269 | 1 | 1 | +| boil2hystoff | hysteresis stage 2 off temperature | int8 (>=0<=20) | C | true | DEVICE_DATA | 269 | 1 | 1 | +| curveon | heatingcurve on | boolean | | true | DEVICE_DATA | 270 | 1 | 1 | uint8 -| curvebase | heatingcurve base | uint8 (>=20<=90) | C | true | DEVICE_DATA | 270 | 1 | 1 | +| curvebase | heatingcurve base | uint8 (>=20<=90) | C | true | DEVICE_DATA | 271 | 1 | 1 | uint8 -| curveend | heatingcurve end | uint8 (>=20<=90) | C | true | DEVICE_DATA | 271 | 1 | 1 | +| curveend | heatingcurve end | uint8 (>=20<=90) | C | true | DEVICE_DATA | 272 | 1 | 1 | uint8 -| summertemp | summer temperature | uint8 (>=0<=45) | C | true | DEVICE_DATA | 272 | 1 | 1 | -| nofrostmode | nofrost mode | boolean | | true | DEVICE_DATA | 273 | 1 | 1 | +| summertemp | summer temperature | uint8 (>=0<=45) | C | true | DEVICE_DATA | 273 | 1 | 1 | +| nofrostmode | nofrost mode | boolean | | true | DEVICE_DATA | 274 | 1 | 1 | uint8 -| nofrosttemp | nofrost temperature | uint8 (>=0<=10) | C | true | DEVICE_DATA | 274 | 1 | 1 | +| nofrosttemp | nofrost temperature | uint8 (>=0<=10) | C | true | DEVICE_DATA | 275 | 1 | 1 | | heatingactivated | heating activated | boolean | | true | DEVICE_DATA | 14 | 1 | 1 | uint8 | heatingtemp | heating temperature | uint8 (>=0<=90) | C | true | DEVICE_DATA | 15 | 1 | 1 | @@ -4920,20 +4948,21 @@ uint16 | emergencyops | emergency operation | boolean | | true | DEVICE_DATA | 78 | 1 | 1 | uint8 | emergencytemp | emergency temperature | uint8 (>=15<=70) | C | true | DEVICE_DATA | 79 | 1 | 1 | -| pc0flow | Flow PC0 | int16 | l/h | false | DEVICE_DATA | 80 | 1 | 1 | -| pc1flow | Flow PC1 | int16 | l/h | false | DEVICE_DATA | 81 | 1 | 1 | -| pc1on | PC1 | boolean | | false | DEVICE_DATA | 82 | 1 | 1 | -| pc1rate | PC1 rate | uint8 | % | false | DEVICE_DATA | 83 | 1 | 1 | +| pc0lpm | Flow PC0 | uint16 | l/min | false | DEVICE_DATA | 80 | 1 | 1/10 | +| pc0flow | Flow PC0 | uint16 | l/h | false | DEVICE_DATA | 81 | 1 | 1 | +| pc1flow | Flow PC1 | uint16 | l/h | false | DEVICE_DATA | 82 | 1 | 1 | +| pc1on | PC1 | boolean | | false | DEVICE_DATA | 83 | 1 | 1 | +| pc1rate | PC1 rate | uint8 | % | false | DEVICE_DATA | 84 | 1 | 1 | uint8 -| pumpkickhour | pump kick hour | uint8 (>=0<=23) | hours | true | DEVICE_DATA | 84 | 1 | 1 | -| pumpkickday | pump kick day | enum | | true | DEVICE_DATA | 85 | 1 | 1 | +| pumpkickhour | pump kick hour | uint8 (>=0<=23) | hours | true | DEVICE_DATA | 85 | 1 | 1 | +| pumpkickday | pump kick day | enum | | true | DEVICE_DATA | 86 | 1 | 1 | uint16 -| pumpkickdelay | pump kick delay | uint16 (>=0<=32767) | minutes | true | DEVICE_DATA | 86 | 1 | 1 | -| meterheat | meter heating | uint24 | kWh | false | DEVICE_DATA | 100 | 2 | 1/10 | +| pumpkickdelay | pump kick delay | uint16 (>=0<=32767) | minutes | true | DEVICE_DATA | 87 | 1 | 1 | +| meterheat | meter heating | uint24 | kWh | false | DEVICE_DATA | 101 | 2 | 1/10 | | dhw.meter | meter | uint24 | kWh | false | DHW | 2 | 2 | 1/10 | -| gasmeterheat | gas meter heating | uint24 | kWh | false | DEVICE_DATA | 275 | 2 | 1/10 | +| gasmeterheat | gas meter heating | uint24 | kWh | false | DEVICE_DATA | 276 | 2 | 1/10 | | dhw.gasmeter | gas meter | uint24 | kWh | false | DHW | 71 | 2 | 1/10 | -| nrgheat2 | energy heating 2 | uint24 | kWh | false | DEVICE_DATA | 277 | 2 | 1/10 | +| nrgheat2 | energy heating 2 | uint24 | kWh | false | DEVICE_DATA | 278 | 2 | 1/10 | | dhw.nrg2 | energy 2 | uint24 | kWh | false | DHW | 73 | 2 | 1/10 | | dhw.tapactivated | turn on/off | boolean | | true | DHW | 28 | 1 | 1 | | dhw.settemp | set temperature | uint8 | C | false | DHW | 29 | 1 | 1 | @@ -4987,10 +5016,10 @@ uint8 | dhw.starts | starts | uint24 | | false | DHW | 67 | 2 | 1 | | dhw.workm | active time | time | minutes | false | DHW | 69 | 2 | 1 | uint8 -| nompower | nominal Power | uint8 (>=0<=0) | kW | true | DEVICE_DATA | 279 | 1 | 1 | -| nrgtotal | total energy | uint24 | kWh | false | DEVICE_DATA | 88 | 2 | 1/100 | +| nompower | nominal Power | uint8 (>=0<=0) | kW | true | DEVICE_DATA | 280 | 1 | 1 | +| nrgtotal | total energy | uint24 | kWh | false | DEVICE_DATA | 89 | 2 | 1/100 | uint24 -| nrgheat | energy heating | uint24 (>=0<=10000000) | kWh | true | DEVICE_DATA | 90 | 2 | 1/100 | +| nrgheat | energy heating | uint24 (>=0<=10000000) | kWh | true | DEVICE_DATA | 91 | 2 | 1/100 | uint24 | dhw.nrg | energy | uint24 (>=0<=10000000) | kWh | true | DHW | 0 | 2 | 1/100 | @@ -4998,14 +5027,14 @@ uint24 | shortname | fullname | type | uom | writeable | tag type | register offset | register count | scale factor | |-|-|-|-|-|-|-|-|-| -| netflowtemp | heat network flow temp | uint16 | C | false | DEVICE_DATA | 280 | 1 | 1/10 | -| heatvalve | heating valve | uint8 | % | false | DEVICE_DATA | 281 | 1 | 1 | +| netflowtemp | heat network flow temp | uint16 | C | false | DEVICE_DATA | 281 | 1 | 1/10 | +| heatvalve | heating valve | uint8 | % | false | DEVICE_DATA | 282 | 1 | 1 | | dhw.dhwvalve | valve | uint8 | % | false | DHW | 75 | 1 | 1 | uint8 -| keepwarmtemp | keep warm temperature | uint8 (>=0<=0) | C | true | DEVICE_DATA | 282 | 1 | 1 | +| keepwarmtemp | keep warm temperature | uint8 (>=0<=0) | C | true | DEVICE_DATA | 283 | 1 | 1 | uint8 -| setreturntemp | set temp return | uint8 (>=0<=0) | C | true | DEVICE_DATA | 283 | 1 | 1 | -| heating | heating | boolean | | false | DEVICE_DATA | 284 | 1 | 1 | +| setreturntemp | set temp return | uint8 (>=0<=0) | C | true | DEVICE_DATA | 284 | 1 | 1 | +| heating | heating | boolean | | false | DEVICE_DATA | 285 | 1 | 1 | | reset | reset | cmd | | true | DEVICE_DATA | 0 | 1 | 1 | | chimneysweeper | chimney sweeper | cmd | | true | DEVICE_DATA | 1 | 1 | 1 | | heatingoff | force heating off | boolean | | true | DEVICE_DATA | 2 | 1 | 1 | @@ -5055,20 +5084,21 @@ uint16 | emergencyops | emergency operation | boolean | | true | DEVICE_DATA | 78 | 1 | 1 | uint8 | emergencytemp | emergency temperature | uint8 (>=15<=70) | C | true | DEVICE_DATA | 79 | 1 | 1 | -| pc0flow | Flow PC0 | int16 | l/h | false | DEVICE_DATA | 80 | 1 | 1 | -| pc1flow | Flow PC1 | int16 | l/h | false | DEVICE_DATA | 81 | 1 | 1 | -| pc1on | PC1 | boolean | | false | DEVICE_DATA | 82 | 1 | 1 | -| pc1rate | PC1 rate | uint8 | % | false | DEVICE_DATA | 83 | 1 | 1 | +| pc0lpm | Flow PC0 | uint16 | l/min | false | DEVICE_DATA | 80 | 1 | 1/10 | +| pc0flow | Flow PC0 | uint16 | l/h | false | DEVICE_DATA | 81 | 1 | 1 | +| pc1flow | Flow PC1 | uint16 | l/h | false | DEVICE_DATA | 82 | 1 | 1 | +| pc1on | PC1 | boolean | | false | DEVICE_DATA | 83 | 1 | 1 | +| pc1rate | PC1 rate | uint8 | % | false | DEVICE_DATA | 84 | 1 | 1 | uint8 -| pumpkickhour | pump kick hour | uint8 (>=0<=23) | hours | true | DEVICE_DATA | 84 | 1 | 1 | -| pumpkickday | pump kick day | enum | | true | DEVICE_DATA | 85 | 1 | 1 | +| pumpkickhour | pump kick hour | uint8 (>=0<=23) | hours | true | DEVICE_DATA | 85 | 1 | 1 | +| pumpkickday | pump kick day | enum | | true | DEVICE_DATA | 86 | 1 | 1 | uint16 -| pumpkickdelay | pump kick delay | uint16 (>=0<=32767) | minutes | true | DEVICE_DATA | 86 | 1 | 1 | -| meterheat | meter heating | uint24 | kWh | false | DEVICE_DATA | 100 | 2 | 1/10 | +| pumpkickdelay | pump kick delay | uint16 (>=0<=32767) | minutes | true | DEVICE_DATA | 87 | 1 | 1 | +| meterheat | meter heating | uint24 | kWh | false | DEVICE_DATA | 101 | 2 | 1/10 | | dhw.meter | meter | uint24 | kWh | false | DHW | 2 | 2 | 1/10 | -| gasmeterheat | gas meter heating | uint24 | kWh | false | DEVICE_DATA | 275 | 2 | 1/10 | +| gasmeterheat | gas meter heating | uint24 | kWh | false | DEVICE_DATA | 276 | 2 | 1/10 | | dhw.gasmeter | gas meter | uint24 | kWh | false | DHW | 71 | 2 | 1/10 | -| nrgheat2 | energy heating 2 | uint24 | kWh | false | DEVICE_DATA | 277 | 2 | 1/10 | +| nrgheat2 | energy heating 2 | uint24 | kWh | false | DEVICE_DATA | 278 | 2 | 1/10 | | dhw.nrg2 | energy 2 | uint24 | kWh | false | DHW | 73 | 2 | 1/10 | | dhw.tapactivated | turn on/off | boolean | | true | DHW | 28 | 1 | 1 | | dhw.settemp | set temperature | uint8 | C | false | DHW | 29 | 1 | 1 | @@ -5141,39 +5171,39 @@ uint8 | syspress | system pressure | uint8 | bar | false | DEVICE_DATA | 11 | 1 | 1/10 | | boiltemp | actual boiler temperature | uint16 | C | false | DEVICE_DATA | 12 | 1 | 1/10 | | headertemp | low loss header | uint16 | C | false | DEVICE_DATA | 13 | 1 | 1/10 | -| exhausttemp | exhaust temperature | uint16 | C | false | DEVICE_DATA | 253 | 1 | 1/10 | -| burngas | gas | boolean | | false | DEVICE_DATA | 254 | 1 | 1 | -| burngas2 | gas stage 2 | boolean | | false | DEVICE_DATA | 255 | 1 | 1 | -| flamecurr | flame current | uint16 | µA | false | DEVICE_DATA | 256 | 1 | 1/10 | -| fanwork | fan | boolean | | false | DEVICE_DATA | 257 | 1 | 1 | -| ignwork | ignition | boolean | | false | DEVICE_DATA | 258 | 1 | 1 | -| oilpreheat | oil preheating | boolean | | false | DEVICE_DATA | 259 | 1 | 1 | +| exhausttemp | exhaust temperature | uint16 | C | false | DEVICE_DATA | 254 | 1 | 1/10 | +| burngas | gas | boolean | | false | DEVICE_DATA | 255 | 1 | 1 | +| burngas2 | gas stage 2 | boolean | | false | DEVICE_DATA | 256 | 1 | 1 | +| flamecurr | flame current | uint16 | µA | false | DEVICE_DATA | 257 | 1 | 1/10 | +| fanwork | fan | boolean | | false | DEVICE_DATA | 258 | 1 | 1 | +| ignwork | ignition | boolean | | false | DEVICE_DATA | 259 | 1 | 1 | +| oilpreheat | oil preheating | boolean | | false | DEVICE_DATA | 260 | 1 | 1 | uint8 -| burnminpower | burner min power | uint8 (>=0<=0) | % | true | DEVICE_DATA | 260 | 1 | 1 | +| burnminpower | burner min power | uint8 (>=0<=0) | % | true | DEVICE_DATA | 261 | 1 | 1 | uint8 -| burnmaxpower | burner max power | uint8 (>=0<=254) | % | true | DEVICE_DATA | 261 | 1 | 1 | +| burnmaxpower | burner max power | uint8 (>=0<=254) | % | true | DEVICE_DATA | 262 | 1 | 1 | uint8 -| burnminperiod | burner min period | uint8 (>=0<=120) | minutes | true | DEVICE_DATA | 262 | 1 | 1 | -| absburnpow | burner current power (absolute) | uint8 | % | false | DEVICE_DATA | 263 | 1 | 1 | -| heatblock | Heatblock temperature | uint16 | C | false | DEVICE_DATA | 264 | 1 | 1/10 | +| burnminperiod | burner min period | uint8 (>=0<=120) | minutes | true | DEVICE_DATA | 263 | 1 | 1 | +| absburnpow | burner current power (absolute) | uint8 | % | false | DEVICE_DATA | 264 | 1 | 1 | +| heatblock | Heatblock temperature | uint16 | C | false | DEVICE_DATA | 265 | 1 | 1/10 | int8 -| boilhyston | hysteresis on temperature | int8 (>=-20<=0) | C | true | DEVICE_DATA | 265 | 1 | 1 | +| boilhyston | hysteresis on temperature | int8 (>=-20<=0) | C | true | DEVICE_DATA | 266 | 1 | 1 | int8 -| boilhystoff | hysteresis off temperature | int8 (>=0<=20) | C | true | DEVICE_DATA | 266 | 1 | 1 | +| boilhystoff | hysteresis off temperature | int8 (>=0<=20) | C | true | DEVICE_DATA | 267 | 1 | 1 | int8 -| boil2hyston | hysteresis stage 2 on temperature | int8 (>=-20<=0) | C | true | DEVICE_DATA | 267 | 1 | 1 | +| boil2hyston | hysteresis stage 2 on temperature | int8 (>=-20<=0) | C | true | DEVICE_DATA | 268 | 1 | 1 | int8 -| boil2hystoff | hysteresis stage 2 off temperature | int8 (>=0<=20) | C | true | DEVICE_DATA | 268 | 1 | 1 | -| curveon | heatingcurve on | boolean | | true | DEVICE_DATA | 269 | 1 | 1 | +| boil2hystoff | hysteresis stage 2 off temperature | int8 (>=0<=20) | C | true | DEVICE_DATA | 269 | 1 | 1 | +| curveon | heatingcurve on | boolean | | true | DEVICE_DATA | 270 | 1 | 1 | uint8 -| curvebase | heatingcurve base | uint8 (>=20<=90) | C | true | DEVICE_DATA | 270 | 1 | 1 | +| curvebase | heatingcurve base | uint8 (>=20<=90) | C | true | DEVICE_DATA | 271 | 1 | 1 | uint8 -| curveend | heatingcurve end | uint8 (>=20<=90) | C | true | DEVICE_DATA | 271 | 1 | 1 | +| curveend | heatingcurve end | uint8 (>=20<=90) | C | true | DEVICE_DATA | 272 | 1 | 1 | uint8 -| summertemp | summer temperature | uint8 (>=0<=45) | C | true | DEVICE_DATA | 272 | 1 | 1 | -| nofrostmode | nofrost mode | boolean | | true | DEVICE_DATA | 273 | 1 | 1 | +| summertemp | summer temperature | uint8 (>=0<=45) | C | true | DEVICE_DATA | 273 | 1 | 1 | +| nofrostmode | nofrost mode | boolean | | true | DEVICE_DATA | 274 | 1 | 1 | uint8 -| nofrosttemp | nofrost temperature | uint8 (>=0<=10) | C | true | DEVICE_DATA | 274 | 1 | 1 | +| nofrosttemp | nofrost temperature | uint8 (>=0<=10) | C | true | DEVICE_DATA | 275 | 1 | 1 | | heatingactivated | heating activated | boolean | | true | DEVICE_DATA | 14 | 1 | 1 | uint8 | heatingtemp | heating temperature | uint8 (>=0<=90) | C | true | DEVICE_DATA | 15 | 1 | 1 | @@ -5208,20 +5238,21 @@ uint16 | emergencyops | emergency operation | boolean | | true | DEVICE_DATA | 78 | 1 | 1 | uint8 | emergencytemp | emergency temperature | uint8 (>=15<=70) | C | true | DEVICE_DATA | 79 | 1 | 1 | -| pc0flow | Flow PC0 | int16 | l/h | false | DEVICE_DATA | 80 | 1 | 1 | -| pc1flow | Flow PC1 | int16 | l/h | false | DEVICE_DATA | 81 | 1 | 1 | -| pc1on | PC1 | boolean | | false | DEVICE_DATA | 82 | 1 | 1 | -| pc1rate | PC1 rate | uint8 | % | false | DEVICE_DATA | 83 | 1 | 1 | +| pc0lpm | Flow PC0 | uint16 | l/min | false | DEVICE_DATA | 80 | 1 | 1/10 | +| pc0flow | Flow PC0 | uint16 | l/h | false | DEVICE_DATA | 81 | 1 | 1 | +| pc1flow | Flow PC1 | uint16 | l/h | false | DEVICE_DATA | 82 | 1 | 1 | +| pc1on | PC1 | boolean | | false | DEVICE_DATA | 83 | 1 | 1 | +| pc1rate | PC1 rate | uint8 | % | false | DEVICE_DATA | 84 | 1 | 1 | uint8 -| pumpkickhour | pump kick hour | uint8 (>=0<=23) | hours | true | DEVICE_DATA | 84 | 1 | 1 | -| pumpkickday | pump kick day | enum | | true | DEVICE_DATA | 85 | 1 | 1 | +| pumpkickhour | pump kick hour | uint8 (>=0<=23) | hours | true | DEVICE_DATA | 85 | 1 | 1 | +| pumpkickday | pump kick day | enum | | true | DEVICE_DATA | 86 | 1 | 1 | uint16 -| pumpkickdelay | pump kick delay | uint16 (>=0<=32767) | minutes | true | DEVICE_DATA | 86 | 1 | 1 | -| meterheat | meter heating | uint24 | kWh | false | DEVICE_DATA | 100 | 2 | 1/10 | +| pumpkickdelay | pump kick delay | uint16 (>=0<=32767) | minutes | true | DEVICE_DATA | 87 | 1 | 1 | +| meterheat | meter heating | uint24 | kWh | false | DEVICE_DATA | 101 | 2 | 1/10 | | dhw.meter | meter | uint24 | kWh | false | DHW | 2 | 2 | 1/10 | -| gasmeterheat | gas meter heating | uint24 | kWh | false | DEVICE_DATA | 275 | 2 | 1/10 | +| gasmeterheat | gas meter heating | uint24 | kWh | false | DEVICE_DATA | 276 | 2 | 1/10 | | dhw.gasmeter | gas meter | uint24 | kWh | false | DHW | 71 | 2 | 1/10 | -| nrgheat2 | energy heating 2 | uint24 | kWh | false | DEVICE_DATA | 277 | 2 | 1/10 | +| nrgheat2 | energy heating 2 | uint24 | kWh | false | DEVICE_DATA | 278 | 2 | 1/10 | | dhw.nrg2 | energy 2 | uint24 | kWh | false | DHW | 73 | 2 | 1/10 | | dhw.tapactivated | turn on/off | boolean | | true | DHW | 28 | 1 | 1 | | dhw.settemp | set temperature | uint8 | C | false | DHW | 29 | 1 | 1 | @@ -5275,10 +5306,10 @@ uint8 | dhw.starts | starts | uint24 | | false | DHW | 67 | 2 | 1 | | dhw.workm | active time | time | minutes | false | DHW | 69 | 2 | 1 | uint8 -| nompower | nominal Power | uint8 (>=0<=0) | kW | true | DEVICE_DATA | 279 | 1 | 1 | -| nrgtotal | total energy | uint24 | kWh | false | DEVICE_DATA | 88 | 2 | 1/100 | +| nompower | nominal Power | uint8 (>=0<=0) | kW | true | DEVICE_DATA | 280 | 1 | 1 | +| nrgtotal | total energy | uint24 | kWh | false | DEVICE_DATA | 89 | 2 | 1/100 | uint24 -| nrgheat | energy heating | uint24 (>=0<=10000000) | kWh | true | DEVICE_DATA | 90 | 2 | 1/100 | +| nrgheat | energy heating | uint24 (>=0<=10000000) | kWh | true | DEVICE_DATA | 91 | 2 | 1/100 | uint24 | dhw.nrg | energy | uint24 (>=0<=10000000) | kWh | true | DHW | 0 | 2 | 1/100 | diff --git a/docs/dump_entities.csv b/docs/dump_entities.csv index 660b7c49b..582082fd4 100644 --- a/docs/dump_entities.csv +++ b/docs/dump_entities.csv @@ -39,130 +39,131 @@ device name,device type,product id,shortname,fullname,type [options...] \| (min/ "CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,maintenancedate,next maintenance date,string (>=0<=0), ,true,sensor.boiler_next_maintenance_date,sensor.boiler_maintenancedate,6,0,1,72,6 "CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,emergencyops,emergency operation,boolean (>=0<=0), ,true,switch.boiler_emergency_operation,switch.boiler_emergencyops,6,0,1,78,1 "CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,emergencytemp,emergency temperature,uint8 (>=15<=70),C,true,number.boiler_emergency_temperature,number.boiler_emergencytemp,6,0,1,79,1 -"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,pc0flow,Flow PC0,int16,l/h,false,sensor.boiler_Flow_PC0,sensor.boiler_pc0flow,6,0,1,80,1 -"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,pc1flow,Flow PC1,int16,l/h,false,sensor.boiler_Flow_PC1,sensor.boiler_pc1flow,6,0,1,81,1 -"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,pc1on,PC1,boolean, ,false,binary_sensor.boiler_PC1,binary_sensor.boiler_pc1on,6,0,1,82,1 -"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,pc1rate,PC1 rate,uint8,%,false,sensor.boiler_PC1_rate,sensor.boiler_pc1rate,6,0,1,83,1 -"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,pumpkickhour,pump kick hour,uint8 (>=0<=23),hours,true,number.boiler_pump_kick_hour,number.boiler_pumpkickhour,6,0,1,84,1 -"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,pumpkickday,pump kick day,enum [mo\|tu\|we\|th\|fr\|sa\|su\|all] (>=0<=0), ,true,select.boiler_pump_kick_day,select.boiler_pumpkickday,6,0,1,85,1 -"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,pumpkickdelay,pump kick delay,uint16 (>=0<=32767),minutes,true,number.boiler_pump_kick_delay,number.boiler_pumpkickdelay,6,0,1,86,1 -"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,mandefrost,manual defrost,cmd [off\|on] (>=0<=0), ,true,sensor.boiler_manual_defrost,sensor.boiler_mandefrost,6,0,1,87,1 -"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,nrgtotal,total energy,uint24,kWh,false,sensor.boiler_total_energy,sensor.boiler_nrgtotal,6,0,1/100,88,2 +"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,pc0lpm,Flow PC0,uint16,l/min,false,sensor.boiler_Flow_PC0,sensor.boiler_pc0lpm,6,0,1/10,80,1 +"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,pc0flow,Flow PC0,uint16,l/h,false,sensor.boiler_Flow_PC0,sensor.boiler_pc0flow,6,0,1,81,1 +"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,pc1flow,Flow PC1,uint16,l/h,false,sensor.boiler_Flow_PC1,sensor.boiler_pc1flow,6,0,1,82,1 +"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,pc1on,PC1,boolean, ,false,binary_sensor.boiler_PC1,binary_sensor.boiler_pc1on,6,0,1,83,1 +"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,pc1rate,PC1 rate,uint8,%,false,sensor.boiler_PC1_rate,sensor.boiler_pc1rate,6,0,1,84,1 +"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,pumpkickhour,pump kick hour,uint8 (>=0<=23),hours,true,number.boiler_pump_kick_hour,number.boiler_pumpkickhour,6,0,1,85,1 +"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,pumpkickday,pump kick day,enum [mo\|tu\|we\|th\|fr\|sa\|su\|all] (>=0<=0), ,true,select.boiler_pump_kick_day,select.boiler_pumpkickday,6,0,1,86,1 +"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,pumpkickdelay,pump kick delay,uint16 (>=0<=32767),minutes,true,number.boiler_pump_kick_delay,number.boiler_pumpkickdelay,6,0,1,87,1 +"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,mandefrost,manual defrost,cmd [off\|on] (>=0<=0), ,true,sensor.boiler_manual_defrost,sensor.boiler_mandefrost,6,0,1,88,1 +"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,nrgtotal,total energy,uint24,kWh,false,sensor.boiler_total_energy,sensor.boiler_nrgtotal,6,0,1/100,89,2 "CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,dhw.nrg,energy,uint24,kWh,false,sensor.boiler_dhw_energy,sensor.boiler_dhw_nrg,6,9,1/100,0,2 -"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,nrgheat,energy heating,uint24,kWh,false,sensor.boiler_energy_heating,sensor.boiler_nrgheat,6,0,1/100,90,2 -"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,nrgcool,energy cooling,uint24,kWh,false,sensor.boiler_energy_cooling,sensor.boiler_nrgcool,6,0,1/100,92,2 -"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,metertotal,meter total,uint24,kWh,false,sensor.boiler_meter_total,sensor.boiler_metertotal,6,0,1/100,94,2 -"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,metercomp,meter compressor,uint24,kWh,false,sensor.boiler_meter_compressor,sensor.boiler_metercomp,6,0,1/100,96,2 -"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,metereheat,meter e-heater,uint24,kWh,false,sensor.boiler_meter_e-heater,sensor.boiler_metereheat,6,0,1/100,98,2 -"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,meterheat,meter heating,uint24,kWh,false,sensor.boiler_meter_heating,sensor.boiler_meterheat,6,0,1/100,100,2 -"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,metercool,meter cooling,uint24,kWh,false,sensor.boiler_meter_cooling,sensor.boiler_metercool,6,0,1/100,102,2 +"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,nrgheat,energy heating,uint24,kWh,false,sensor.boiler_energy_heating,sensor.boiler_nrgheat,6,0,1/100,91,2 +"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,nrgcool,energy cooling,uint24,kWh,false,sensor.boiler_energy_cooling,sensor.boiler_nrgcool,6,0,1/100,93,2 +"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,metertotal,meter total,uint24,kWh,false,sensor.boiler_meter_total,sensor.boiler_metertotal,6,0,1/100,95,2 +"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,metercomp,meter compressor,uint24,kWh,false,sensor.boiler_meter_compressor,sensor.boiler_metercomp,6,0,1/100,97,2 +"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,metereheat,meter e-heater,uint24,kWh,false,sensor.boiler_meter_e-heater,sensor.boiler_metereheat,6,0,1/100,99,2 +"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,meterheat,meter heating,uint24,kWh,false,sensor.boiler_meter_heating,sensor.boiler_meterheat,6,0,1/100,101,2 +"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,metercool,meter cooling,uint24,kWh,false,sensor.boiler_meter_cooling,sensor.boiler_metercool,6,0,1/100,103,2 "CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,dhw.meter,meter,uint24,kWh,false,sensor.boiler_dhw_meter,sensor.boiler_dhw_meter,6,9,1/100,2,2 -"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,uptimetotal,heatpump total uptime,time,minutes,false,sensor.boiler_heatpump_total_uptime,sensor.boiler_uptimetotal,6,0,1/60,104,2 -"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,uptimecontrol,total operating time heat,time,minutes,false,sensor.boiler_total_operating_time_heat,sensor.boiler_uptimecontrol,6,0,1/60,106,2 -"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,uptimecompheating,operating time compressor heating,time,minutes,false,sensor.boiler_operating_time_compressor_heating,sensor.boiler_uptimecompheating,6,0,1/60,108,2 -"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,uptimecompcooling,operating time compressor cooling,time,minutes,false,sensor.boiler_operating_time_compressor_cooling,sensor.boiler_uptimecompcooling,6,0,1/60,110,2 +"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,uptimetotal,heatpump total uptime,time,minutes,false,sensor.boiler_heatpump_total_uptime,sensor.boiler_uptimetotal,6,0,1/60,105,2 +"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,uptimecontrol,total operating time heat,time,minutes,false,sensor.boiler_total_operating_time_heat,sensor.boiler_uptimecontrol,6,0,1/60,107,2 +"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,uptimecompheating,operating time compressor heating,time,minutes,false,sensor.boiler_operating_time_compressor_heating,sensor.boiler_uptimecompheating,6,0,1/60,109,2 +"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,uptimecompcooling,operating time compressor cooling,time,minutes,false,sensor.boiler_operating_time_compressor_cooling,sensor.boiler_uptimecompcooling,6,0,1/60,111,2 "CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,dhw.uptimecomp,operating time compressor,time,minutes,false,sensor.boiler_dhw_operating_time_compressor,sensor.boiler_dhw_uptimecomp,6,9,1/60,4,2 -"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,uptimecomppool,operating time compressor pool,time,minutes,false,sensor.boiler_operating_time_compressor_pool,sensor.boiler_uptimecomppool,6,0,1/60,112,2 -"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,totalcompstarts,total compressor control starts,uint24, ,false,sensor.boiler_total_compressor_control_starts,sensor.boiler_totalcompstarts,6,0,1,114,2 -"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,heatingstarts,heating control starts,uint24, ,false,sensor.boiler_heating_control_starts,sensor.boiler_heatingstarts,6,0,1,116,2 -"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,coolingstarts,cooling control starts,uint24, ,false,sensor.boiler_cooling_control_starts,sensor.boiler_coolingstarts,6,0,1,118,2 +"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,uptimecomppool,operating time compressor pool,time,minutes,false,sensor.boiler_operating_time_compressor_pool,sensor.boiler_uptimecomppool,6,0,1/60,113,2 +"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,totalcompstarts,total compressor control starts,uint24, ,false,sensor.boiler_total_compressor_control_starts,sensor.boiler_totalcompstarts,6,0,1,115,2 +"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,heatingstarts,heating control starts,uint24, ,false,sensor.boiler_heating_control_starts,sensor.boiler_heatingstarts,6,0,1,117,2 +"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,coolingstarts,cooling control starts,uint24, ,false,sensor.boiler_cooling_control_starts,sensor.boiler_coolingstarts,6,0,1,119,2 "CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,dhw.startshp,starts hp,uint24, ,false,sensor.boiler_dhw_starts_hp,sensor.boiler_dhw_startshp,6,9,1,6,2 -"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,poolstarts,pool control starts,uint24, ,false,sensor.boiler_pool_control_starts,sensor.boiler_poolstarts,6,0,1,120,2 -"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,nrgconstotal,total energy consumption,uint24,kWh,false,sensor.boiler_total_energy_consumption,sensor.boiler_nrgconstotal,6,0,1,122,2 -"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,nrgconscomptotal,total energy consumption compressor,uint24,kWh,false,sensor.boiler_total_energy_consumption_compressor,sensor.boiler_nrgconscomptotal,6,0,1,124,2 -"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,nrgconscompheating,energy consumption compressor heating,uint24,kWh,false,sensor.boiler_energy_consumption_compressor_heating,sensor.boiler_nrgconscompheating,6,0,1,126,2 +"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,poolstarts,pool control starts,uint24, ,false,sensor.boiler_pool_control_starts,sensor.boiler_poolstarts,6,0,1,121,2 +"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,nrgconstotal,total energy consumption,uint24,kWh,false,sensor.boiler_total_energy_consumption,sensor.boiler_nrgconstotal,6,0,1,123,2 +"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,nrgconscomptotal,total energy consumption compressor,uint24,kWh,false,sensor.boiler_total_energy_consumption_compressor,sensor.boiler_nrgconscomptotal,6,0,1,125,2 +"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,nrgconscompheating,energy consumption compressor heating,uint24,kWh,false,sensor.boiler_energy_consumption_compressor_heating,sensor.boiler_nrgconscompheating,6,0,1,127,2 "CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,dhw.nrgconscomp,energy consumption compressor,uint24,kWh,false,sensor.boiler_dhw_energy_consumption_compressor,sensor.boiler_dhw_nrgconscomp,6,9,1,8,2 -"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,nrgconscompcooling,energy consumption compressor cooling,uint24,kWh,false,sensor.boiler_energy_consumption_compressor_cooling,sensor.boiler_nrgconscompcooling,6,0,1,128,2 -"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,nrgconscomppool,energy consumption compressor pool,uint24,kWh,false,sensor.boiler_energy_consumption_compressor_pool,sensor.boiler_nrgconscomppool,6,0,1,130,2 -"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,auxelecheatnrgconstotal,total aux elec. heater energy consumption,uint24,kWh,false,sensor.boiler_total_aux_elec._heater_energy_consumption,sensor.boiler_auxelecheatnrgconstotal,6,0,1,132,2 -"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,auxelecheatnrgconsheating,aux elec. heater energy consumption heating,uint24,kWh,false,sensor.boiler_aux_elec._heater_energy_consumption_heating,sensor.boiler_auxelecheatnrgconsheating,6,0,1,134,2 +"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,nrgconscompcooling,energy consumption compressor cooling,uint24,kWh,false,sensor.boiler_energy_consumption_compressor_cooling,sensor.boiler_nrgconscompcooling,6,0,1,129,2 +"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,nrgconscomppool,energy consumption compressor pool,uint24,kWh,false,sensor.boiler_energy_consumption_compressor_pool,sensor.boiler_nrgconscomppool,6,0,1,131,2 +"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,auxelecheatnrgconstotal,total aux elec. heater energy consumption,uint24,kWh,false,sensor.boiler_total_aux_elec._heater_energy_consumption,sensor.boiler_auxelecheatnrgconstotal,6,0,1,133,2 +"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,auxelecheatnrgconsheating,aux elec. heater energy consumption heating,uint24,kWh,false,sensor.boiler_aux_elec._heater_energy_consumption_heating,sensor.boiler_auxelecheatnrgconsheating,6,0,1,135,2 "CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,dhw.auxelecheatnrgcons,aux elec. heater energy consumption,uint24,kWh,false,sensor.boiler_dhw_aux_elec._heater_energy_consumption,sensor.boiler_dhw_auxelecheatnrgcons,6,9,1,10,2 -"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,auxelecheatnrgconspool,aux elec. heater energy consumption pool,uint24,kWh,false,sensor.boiler_aux_elec._heater_energy_consumption_pool,sensor.boiler_auxelecheatnrgconspool,6,0,1,136,2 -"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,nrgsupptotal,total energy supplied,uint24,kWh,false,sensor.boiler_total_energy_supplied,sensor.boiler_nrgsupptotal,6,0,1,138,2 -"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,nrgsuppheating,total energy supplied heating,uint24,kWh,false,sensor.boiler_total_energy_supplied_heating,sensor.boiler_nrgsuppheating,6,0,1,140,2 +"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,auxelecheatnrgconspool,aux elec. heater energy consumption pool,uint24,kWh,false,sensor.boiler_aux_elec._heater_energy_consumption_pool,sensor.boiler_auxelecheatnrgconspool,6,0,1,137,2 +"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,nrgsupptotal,total energy supplied,uint24,kWh,false,sensor.boiler_total_energy_supplied,sensor.boiler_nrgsupptotal,6,0,1,139,2 +"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,nrgsuppheating,total energy supplied heating,uint24,kWh,false,sensor.boiler_total_energy_supplied_heating,sensor.boiler_nrgsuppheating,6,0,1,141,2 "CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,dhw.nrgsupp,total energy warm supplied,uint24,kWh,false,sensor.boiler_dhw_total_energy_warm_supplied,sensor.boiler_dhw_nrgsupp,6,9,1,12,2 -"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,nrgsuppcooling,total energy supplied cooling,uint24,kWh,false,sensor.boiler_total_energy_supplied_cooling,sensor.boiler_nrgsuppcooling,6,0,1,142,2 -"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,nrgsupppool,total energy supplied pool,uint24,kWh,false,sensor.boiler_total_energy_supplied_pool,sensor.boiler_nrgsupppool,6,0,1,144,2 -"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,hppower,compressor power output,uint16,kW,false,sensor.boiler_compressor_power_output,sensor.boiler_hppower,6,0,1/10,146,1 -"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,hpmaxpower,compressor max power,uint8 (>=0<=0),%,true,number.boiler_compressor_max_power,number.boiler_hpmaxpower,6,0,1,147,1 -"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,pvmaxcomp,pv compressor max power,uint8 (>=0<=0),kW,true,number.boiler_pv_compressor_max_power,number.boiler_pvmaxcomp,6,0,1/10,148,1 -"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,powerreduction,power reduction,uint8 (>=30<=60),%,true,number.boiler_power_reduction,number.boiler_powerreduction,6,0,10,149,1 -"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,hpsetdiffpress,set differential pressure,uint8 (>=150<=750),mbar,true,number.boiler_set_differential_pressure,number.boiler_hpsetdiffpress,6,0,50,150,1 -"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,hpcompon,hp compressor,boolean, ,false,binary_sensor.boiler_hp_compressor,binary_sensor.boiler_hpcompon,6,0,1,151,1 -"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,hpactivity,compressor activity,enum [off\|heating\|cooling\|hot water\|pool\|pool heating\|defrost\|compressor alarm], ,false,sensor.boiler_compressor_activity,sensor.boiler_hpactivity,6,0,1,152,1 -"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,hpbrinepumpspd,brine pump speed,uint8,%,false,sensor.boiler_brine_pump_speed,sensor.boiler_hpbrinepumpspd,6,0,1,153,1 -"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,hpswitchvalve,switch valve,boolean, ,false,binary_sensor.boiler_switch_valve,binary_sensor.boiler_hpswitchvalve,6,0,1,154,1 -"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,hpcompspd,compressor speed,uint8,%,false,sensor.boiler_compressor_speed,sensor.boiler_hpcompspd,6,0,1,155,1 -"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,hptargetspd,compressor target speed,uint8,%,false,sensor.boiler_compressor_target_speed,sensor.boiler_hptargetspd,6,0,1,156,1 -"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,hpcircspd,circulation pump speed,uint8,%,false,sensor.boiler_circulation_pump_speed,sensor.boiler_hpcircspd,6,0,1,157,1 -"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,recvalve,receiver valve VR0,uint8,%,false,sensor.boiler_receiver_valve_VR0,sensor.boiler_recvalve,6,0,1,158,1 -"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,expvalve,expansion valve VR1,uint8,%,false,sensor.boiler_expansion_valve_VR1,sensor.boiler_expvalve,6,0,1,159,1 -"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,hpbrinein,brine in/evaporator,int16,C,false,sensor.boiler_brine_in/evaporator,sensor.boiler_hpbrinein,6,0,1/10,160,1 -"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,hpbrineout,brine out/condenser,int16,C,false,sensor.boiler_brine_out/condenser,sensor.boiler_hpbrineout,6,0,1/10,161,1 -"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,hptc0,heat carrier return (TC0),int16,C,false,sensor.boiler_heat_carrier_return_(TC0),sensor.boiler_hptc0,6,0,1/10,162,1 -"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,hptc1,heat carrier forward (TC1),int16,C,false,sensor.boiler_heat_carrier_forward_(TC1),sensor.boiler_hptc1,6,0,1/10,163,1 -"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,hptc3,condenser temperature (TC3),int16,C,false,sensor.boiler_condenser_temperature_(TC3),sensor.boiler_hptc3,6,0,1/10,164,1 -"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,hptr1,compressor temperature (TR1),int16,C,false,sensor.boiler_compressor_temperature_(TR1),sensor.boiler_hptr1,6,0,1/10,165,1 -"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,hptr3,refrigerant temperature liquid side (condenser output) (TR3),int16,C,false,sensor.boiler_refrigerant_temperature_liquid_side_(condenser_output)_(TR3),sensor.boiler_hptr3,6,0,1/10,166,1 -"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,hptr4,evaporator inlet temperature (TR4),int16,C,false,sensor.boiler_evaporator_inlet_temperature_(TR4),sensor.boiler_hptr4,6,0,1/10,167,1 -"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,hptr5,compressor inlet temperature (TR5),int16,C,false,sensor.boiler_compressor_inlet_temperature_(TR5),sensor.boiler_hptr5,6,0,1/10,168,1 -"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,hptr6,compressor outlet temperature (TR6),int16,C,false,sensor.boiler_compressor_outlet_temperature_(TR6),sensor.boiler_hptr6,6,0,1/10,169,1 -"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,hptr7,refrigerant temperature gas side (condenser input) (TR7),int16,C,false,sensor.boiler_refrigerant_temperature_gas_side_(condenser_input)_(TR7),sensor.boiler_hptr7,6,0,1/10,170,1 -"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,hptl2,air inlet temperature (TL2),int16,C,false,sensor.boiler_air_inlet_temperature_(TL2),sensor.boiler_hptl2,6,0,1/10,171,1 -"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,hppl1,low pressure side temperature (PL1),int16,C,false,sensor.boiler_low_pressure_side_temperature_(PL1),sensor.boiler_hppl1,6,0,1/10,172,1 -"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,hpph1,high pressure side temperature (PH1),int16,C,false,sensor.boiler_high_pressure_side_temperature_(PH1),sensor.boiler_hpph1,6,0,1/10,173,1 -"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,hpta4,drain pan temp (TA4),int16,C,false,sensor.boiler_drain_pan_temp_(TA4),sensor.boiler_hpta4,6,0,1/10,174,1 -"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,hptw1,reservoir temp (TW1),int16,C,false,sensor.boiler_reservoir_temp_(TW1),sensor.boiler_hptw1,6,0,1/10,175,1 -"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,poolsettemp,pool set temperature,uint8 (>=0<=0),C,true,number.boiler_pool_set_temperature,number.boiler_poolsettemp,6,0,1/2,176,1 -"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,hp4way,4-way valve (VR4),boolean, ,false,binary_sensor.boiler_4-way_valve_(VR4),binary_sensor.boiler_hp4way,6,0,1,177,1 -"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,hpin1,input 1 state,boolean, ,false,binary_sensor.boiler_input_1_state,binary_sensor.boiler_hpin1,6,0,1,178,1 -"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,hpin1opt,input 1 options,string (>=0<=0), ,true,sensor.boiler_input_1_options,sensor.boiler_hpin1opt,6,0,1,179,8 -"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,hpin2,input 2 state,boolean, ,false,binary_sensor.boiler_input_2_state,binary_sensor.boiler_hpin2,6,0,1,187,1 -"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,hpin2opt,input 2 options,string (>=0<=0), ,true,sensor.boiler_input_2_options,sensor.boiler_hpin2opt,6,0,1,188,8 -"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,hpin3,input 3 state,boolean, ,false,binary_sensor.boiler_input_3_state,binary_sensor.boiler_hpin3,6,0,1,196,1 -"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,hpin3opt,input 3 options,string (>=0<=0), ,true,sensor.boiler_input_3_options,sensor.boiler_hpin3opt,6,0,1,197,8 -"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,hpin4,input 4 state,boolean, ,false,binary_sensor.boiler_input_4_state,binary_sensor.boiler_hpin4,6,0,1,205,1 -"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,hpin4opt,input 4 options,string (>=0<=0), ,true,sensor.boiler_input_4_options,sensor.boiler_hpin4opt,6,0,1,206,8 -"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,maxheatcomp,heat limit compressor,enum [0 kW\|3 kW\|6 kW\|9 kW] (>=0<=0), ,true,select.boiler_heat_limit_compressor,select.boiler_maxheatcomp,6,0,1,214,1 -"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,maxheatheat,heat limit heating,enum [3 kW\|6 kW\|9 kW] (>=0<=0), ,true,select.boiler_heat_limit_heating,select.boiler_maxheatheat,6,0,1,215,1 +"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,nrgsuppcooling,total energy supplied cooling,uint24,kWh,false,sensor.boiler_total_energy_supplied_cooling,sensor.boiler_nrgsuppcooling,6,0,1,143,2 +"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,nrgsupppool,total energy supplied pool,uint24,kWh,false,sensor.boiler_total_energy_supplied_pool,sensor.boiler_nrgsupppool,6,0,1,145,2 +"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,hppower,compressor power output,uint16,kW,false,sensor.boiler_compressor_power_output,sensor.boiler_hppower,6,0,1/10,147,1 +"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,hpmaxpower,compressor max power,uint8 (>=0<=0),%,true,number.boiler_compressor_max_power,number.boiler_hpmaxpower,6,0,1,148,1 +"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,pvmaxcomp,pv compressor max power,uint8 (>=0<=0),kW,true,number.boiler_pv_compressor_max_power,number.boiler_pvmaxcomp,6,0,1/10,149,1 +"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,powerreduction,power reduction,uint8 (>=30<=60),%,true,number.boiler_power_reduction,number.boiler_powerreduction,6,0,10,150,1 +"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,hpsetdiffpress,set differential pressure,uint8 (>=150<=750),mbar,true,number.boiler_set_differential_pressure,number.boiler_hpsetdiffpress,6,0,50,151,1 +"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,hpcompon,hp compressor,boolean, ,false,binary_sensor.boiler_hp_compressor,binary_sensor.boiler_hpcompon,6,0,1,152,1 +"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,hpactivity,compressor activity,enum [off\|heating\|cooling\|hot water\|pool\|pool heating\|defrost\|compressor alarm], ,false,sensor.boiler_compressor_activity,sensor.boiler_hpactivity,6,0,1,153,1 +"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,hpbrinepumpspd,brine pump speed,uint8,%,false,sensor.boiler_brine_pump_speed,sensor.boiler_hpbrinepumpspd,6,0,1,154,1 +"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,hpswitchvalve,switch valve,boolean, ,false,binary_sensor.boiler_switch_valve,binary_sensor.boiler_hpswitchvalve,6,0,1,155,1 +"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,hpcompspd,compressor speed,uint8,%,false,sensor.boiler_compressor_speed,sensor.boiler_hpcompspd,6,0,1,156,1 +"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,hptargetspd,compressor target speed,uint8,%,false,sensor.boiler_compressor_target_speed,sensor.boiler_hptargetspd,6,0,1,157,1 +"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,hpcircspd,circulation pump speed,uint8,%,false,sensor.boiler_circulation_pump_speed,sensor.boiler_hpcircspd,6,0,1,158,1 +"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,recvalve,receiver valve VR0,uint8,%,false,sensor.boiler_receiver_valve_VR0,sensor.boiler_recvalve,6,0,1,159,1 +"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,expvalve,expansion valve VR1,uint8,%,false,sensor.boiler_expansion_valve_VR1,sensor.boiler_expvalve,6,0,1,160,1 +"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,hpbrinein,brine in/evaporator,int16,C,false,sensor.boiler_brine_in/evaporator,sensor.boiler_hpbrinein,6,0,1/10,161,1 +"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,hpbrineout,brine out/condenser,int16,C,false,sensor.boiler_brine_out/condenser,sensor.boiler_hpbrineout,6,0,1/10,162,1 +"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,hptc0,heat carrier return (TC0),int16,C,false,sensor.boiler_heat_carrier_return_(TC0),sensor.boiler_hptc0,6,0,1/10,163,1 +"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,hptc1,heat carrier forward (TC1),int16,C,false,sensor.boiler_heat_carrier_forward_(TC1),sensor.boiler_hptc1,6,0,1/10,164,1 +"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,hptc3,condenser temperature (TC3),int16,C,false,sensor.boiler_condenser_temperature_(TC3),sensor.boiler_hptc3,6,0,1/10,165,1 +"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,hptr1,compressor temperature (TR1),int16,C,false,sensor.boiler_compressor_temperature_(TR1),sensor.boiler_hptr1,6,0,1/10,166,1 +"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,hptr3,refrigerant temperature liquid side (condenser output) (TR3),int16,C,false,sensor.boiler_refrigerant_temperature_liquid_side_(condenser_output)_(TR3),sensor.boiler_hptr3,6,0,1/10,167,1 +"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,hptr4,evaporator inlet temperature (TR4),int16,C,false,sensor.boiler_evaporator_inlet_temperature_(TR4),sensor.boiler_hptr4,6,0,1/10,168,1 +"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,hptr5,compressor inlet temperature (TR5),int16,C,false,sensor.boiler_compressor_inlet_temperature_(TR5),sensor.boiler_hptr5,6,0,1/10,169,1 +"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,hptr6,compressor outlet temperature (TR6),int16,C,false,sensor.boiler_compressor_outlet_temperature_(TR6),sensor.boiler_hptr6,6,0,1/10,170,1 +"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,hptr7,refrigerant temperature gas side (condenser input) (TR7),int16,C,false,sensor.boiler_refrigerant_temperature_gas_side_(condenser_input)_(TR7),sensor.boiler_hptr7,6,0,1/10,171,1 +"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,hptl2,air inlet temperature (TL2),int16,C,false,sensor.boiler_air_inlet_temperature_(TL2),sensor.boiler_hptl2,6,0,1/10,172,1 +"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,hppl1,low pressure side temperature (PL1),int16,C,false,sensor.boiler_low_pressure_side_temperature_(PL1),sensor.boiler_hppl1,6,0,1/10,173,1 +"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,hpph1,high pressure side temperature (PH1),int16,C,false,sensor.boiler_high_pressure_side_temperature_(PH1),sensor.boiler_hpph1,6,0,1/10,174,1 +"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,hpta4,drain pan temp (TA4),int16,C,false,sensor.boiler_drain_pan_temp_(TA4),sensor.boiler_hpta4,6,0,1/10,175,1 +"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,hptw1,reservoir temp (TW1),int16,C,false,sensor.boiler_reservoir_temp_(TW1),sensor.boiler_hptw1,6,0,1/10,176,1 +"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,poolsettemp,pool set temperature,uint8 (>=0<=0),C,true,number.boiler_pool_set_temperature,number.boiler_poolsettemp,6,0,1/2,177,1 +"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,hp4way,4-way valve (VR4),boolean, ,false,binary_sensor.boiler_4-way_valve_(VR4),binary_sensor.boiler_hp4way,6,0,1,178,1 +"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,hpin1,input 1 state,boolean, ,false,binary_sensor.boiler_input_1_state,binary_sensor.boiler_hpin1,6,0,1,179,1 +"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,hpin1opt,input 1 options,string (>=0<=0), ,true,sensor.boiler_input_1_options,sensor.boiler_hpin1opt,6,0,1,180,8 +"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,hpin2,input 2 state,boolean, ,false,binary_sensor.boiler_input_2_state,binary_sensor.boiler_hpin2,6,0,1,188,1 +"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,hpin2opt,input 2 options,string (>=0<=0), ,true,sensor.boiler_input_2_options,sensor.boiler_hpin2opt,6,0,1,189,8 +"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,hpin3,input 3 state,boolean, ,false,binary_sensor.boiler_input_3_state,binary_sensor.boiler_hpin3,6,0,1,197,1 +"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,hpin3opt,input 3 options,string (>=0<=0), ,true,sensor.boiler_input_3_options,sensor.boiler_hpin3opt,6,0,1,198,8 +"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,hpin4,input 4 state,boolean, ,false,binary_sensor.boiler_input_4_state,binary_sensor.boiler_hpin4,6,0,1,206,1 +"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,hpin4opt,input 4 options,string (>=0<=0), ,true,sensor.boiler_input_4_options,sensor.boiler_hpin4opt,6,0,1,207,8 +"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,maxheatcomp,heat limit compressor,enum [0 kW\|3 kW\|6 kW\|9 kW] (>=0<=0), ,true,select.boiler_heat_limit_compressor,select.boiler_maxheatcomp,6,0,1,215,1 +"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,maxheatheat,heat limit heating,enum [3 kW\|6 kW\|9 kW] (>=0<=0), ,true,select.boiler_heat_limit_heating,select.boiler_maxheatheat,6,0,1,216,1 "CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,dhw.maxheat,heat limit,enum [3 kW\|6 kW\|9 kW] (>=0<=0), ,true,select.boiler_dhw_heat_limit,select.boiler_dhw_maxheat,6,9,1,14,1 -"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,auxheatersource,aux heater source,enum [not installed\|electric heater\|exclusive\|parallel\|hybrid] (>=0<=0), ,true,select.boiler_aux_heater_source,select.boiler_auxheatersource,6,0,1,216,1 -"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,pvcooling,cooling only with PV,boolean (>=0<=0), ,true,switch.boiler_cooling_only_with_PV,switch.boiler_pvcooling,6,0,1,217,1 -"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,auxheateronly,aux heater only,boolean (>=0<=0), ,true,switch.boiler_aux_heater_only,switch.boiler_auxheateronly,6,0,1,218,1 -"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,auxheateroff,disable aux heater,boolean (>=0<=0), ,true,switch.boiler_disable_aux_heater,switch.boiler_auxheateroff,6,0,1,219,1 -"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,auxheaterstatus,aux heater status,enum [off\|heating\|cooling\|hot water\|pool\|pool heating\|defrost\|compressor alarm], ,false,sensor.boiler_aux_heater_status,sensor.boiler_auxheaterstatus,6,0,1,220,1 -"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,auxheaterlevel,aux heater level,uint8,%,false,sensor.boiler_aux_heater_level,sensor.boiler_auxheaterlevel,6,0,1,221,1 -"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,auxheaterdelay,aux heater on delay,uint16 (>=10<=1000),K*min,true,number.boiler_aux_heater_on_delay,number.boiler_auxheaterdelay,6,0,10,222,1 -"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,auxmaxlimit,aux heater max limit,uint8 (>=0<=10),K,true,number.boiler_aux_heater_max_limit,number.boiler_auxmaxlimit,6,0,1/10,223,1 -"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,auxlimitstart,aux heater limit start,uint8 (>=0<=10),K,true,number.boiler_aux_heater_limit_start,number.boiler_auxlimitstart,6,0,1/10,224,1 -"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,auxheatrmode,aux heater mode,enum [eco\|comfort] (>=0<=0), ,true,select.boiler_aux_heater_mode,select.boiler_auxheatrmode,6,0,1,225,1 -"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,hphystheat,on/off hyst heat,uint16 (>=50<=1500),K*min,true,number.boiler_on/off_hyst_heat,number.boiler_hphystheat,6,0,5,226,1 -"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,hphystcool,on/off hyst cool,uint16 (>=50<=1500),K*min,true,number.boiler_on/off_hyst_cool,number.boiler_hphystcool,6,0,5,227,1 -"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,hphystpool,on/off hyst pool,uint16 (>=50<=1500),K*min,true,number.boiler_on/off_hyst_pool,number.boiler_hphystpool,6,0,5,228,1 -"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,silentmode,silent mode,enum [off\|auto\|on] (>=0<=0), ,true,select.boiler_silent_mode,select.boiler_silentmode,6,0,1,229,1 -"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,silentfrom,silent mode from,uint8 (>=0<=0),minutes,true,number.boiler_silent_mode_from,number.boiler_silentfrom,6,0,15,230,1 -"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,silentto,silent mode to,uint8 (>=0<=0),minutes,true,number.boiler_silent_mode_to,number.boiler_silentto,6,0,15,231,1 -"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,mintempsilent,min outside temp for silent mode,int8 (>=0<=0),C,true,number.boiler_min_outside_temp_for_silent_mode,number.boiler_mintempsilent,6,0,1,232,1 -"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,tempparmode,outside temp parallel mode,int8 (>=0<=0),C,true,number.boiler_outside_temp_parallel_mode,number.boiler_tempparmode,6,0,1,233,1 -"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,auxheatmix,aux heater mixing valve,int8,%,false,sensor.boiler_aux_heater_mixing_valve,sensor.boiler_auxheatmix,6,0,1,234,1 -"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,tempdiffheat,temp diff TC3/TC0 heat,uint8 (>=2<=10),K,true,number.boiler_temp_diff_TC3/TC0_heat,number.boiler_tempdiffheat,6,0,1/10,235,1 -"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,tempdiffcool,temp diff TC3/TC0 cool,uint8 (>=2<=10),K,true,number.boiler_temp_diff_TC3/TC0_cool,number.boiler_tempdiffcool,6,0,1/10,236,1 -"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,vpcooling,valve/pump cooling,boolean (>=0<=0), ,true,switch.boiler_valve/pump_cooling,switch.boiler_vpcooling,6,0,1,237,1 -"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,heatcable,heating cable,boolean (>=0<=0), ,true,switch.boiler_heating_cable,switch.boiler_heatcable,6,0,1,238,1 -"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,vc0valve,VC0 valve,boolean (>=0<=0), ,true,switch.boiler_VC0_valve,switch.boiler_vc0valve,6,0,1,239,1 -"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,primepump,primary heatpump,boolean (>=0<=0), ,true,switch.boiler_primary_heatpump,switch.boiler_primepump,6,0,1,240,1 -"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,primepumpmod,primary heatpump modulation,uint8 (>=0<=0),%,true,number.boiler_primary_heatpump_modulation,number.boiler_primepumpmod,6,0,1,241,1 -"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,hp3way,3-way valve,boolean (>=0<=0), ,true,switch.boiler_3-way_valve,switch.boiler_hp3way,6,0,1,242,1 -"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,elheatstep1,el. heater step 1,boolean (>=0<=0), ,true,switch.boiler_el._heater_step_1,switch.boiler_elheatstep1,6,0,1,243,1 -"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,elheatstep2,el. heater step 2,boolean (>=0<=0), ,true,switch.boiler_el._heater_step_2,switch.boiler_elheatstep2,6,0,1,244,1 -"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,elheatstep3,el. heater step 3,boolean (>=0<=0), ,true,switch.boiler_el._heater_step_3,switch.boiler_elheatstep3,6,0,1,245,1 -"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,hpea0,condensate reservoir heating (EA0),boolean, ,false,binary_sensor.boiler_condensate_reservoir_heating_(EA0),binary_sensor.boiler_hpea0,6,0,1,246,1 -"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,hppumpmode,primary heatpump mode,enum [auto\|continuous] (>=0<=0), ,true,select.boiler_primary_heatpump_mode,select.boiler_hppumpmode,6,0,1,247,1 -"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,fan,fan,uint8 (>=20<=100),%,true,number.boiler_fan,number.boiler_fan,6,0,1,248,1 -"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,fanspd,fan speed,uint8,%,false,sensor.boiler_fan_speed,sensor.boiler_fanspd,6,0,1,249,1 -"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,shutdown,shutdown,cmd [off\|on] (>=0<=0), ,true,sensor.boiler_shutdown,sensor.boiler_shutdown,6,0,1,250,1 -"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,hpcurrpower,compressor current power,uint16,W,false,sensor.boiler_compressor_current_power,sensor.boiler_hpcurrpower,6,0,1,251,1 -"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,hppowerlimit,power limit,uint16 (>=0<=0),W,true,number.boiler_power_limit,number.boiler_hppowerlimit,6,0,1,252,1 +"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,auxheatersource,aux heater source,enum [not installed\|electric heater\|exclusive\|parallel\|hybrid] (>=0<=0), ,true,select.boiler_aux_heater_source,select.boiler_auxheatersource,6,0,1,217,1 +"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,pvcooling,cooling only with PV,boolean (>=0<=0), ,true,switch.boiler_cooling_only_with_PV,switch.boiler_pvcooling,6,0,1,218,1 +"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,auxheateronly,aux heater only,boolean (>=0<=0), ,true,switch.boiler_aux_heater_only,switch.boiler_auxheateronly,6,0,1,219,1 +"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,auxheateroff,disable aux heater,boolean (>=0<=0), ,true,switch.boiler_disable_aux_heater,switch.boiler_auxheateroff,6,0,1,220,1 +"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,auxheaterstatus,aux heater status,enum [off\|heating\|cooling\|hot water\|pool\|pool heating\|defrost\|compressor alarm], ,false,sensor.boiler_aux_heater_status,sensor.boiler_auxheaterstatus,6,0,1,221,1 +"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,auxheaterlevel,aux heater level,uint8,%,false,sensor.boiler_aux_heater_level,sensor.boiler_auxheaterlevel,6,0,1,222,1 +"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,auxheaterdelay,aux heater on delay,uint16 (>=10<=1000),K*min,true,number.boiler_aux_heater_on_delay,number.boiler_auxheaterdelay,6,0,10,223,1 +"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,auxmaxlimit,aux heater max limit,uint8 (>=0<=10),K,true,number.boiler_aux_heater_max_limit,number.boiler_auxmaxlimit,6,0,1/10,224,1 +"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,auxlimitstart,aux heater limit start,uint8 (>=0<=10),K,true,number.boiler_aux_heater_limit_start,number.boiler_auxlimitstart,6,0,1/10,225,1 +"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,auxheatrmode,aux heater mode,enum [eco\|comfort] (>=0<=0), ,true,select.boiler_aux_heater_mode,select.boiler_auxheatrmode,6,0,1,226,1 +"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,hphystheat,on/off hyst heat,uint16 (>=50<=1500),K*min,true,number.boiler_on/off_hyst_heat,number.boiler_hphystheat,6,0,5,227,1 +"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,hphystcool,on/off hyst cool,uint16 (>=50<=1500),K*min,true,number.boiler_on/off_hyst_cool,number.boiler_hphystcool,6,0,5,228,1 +"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,hphystpool,on/off hyst pool,uint16 (>=50<=1500),K*min,true,number.boiler_on/off_hyst_pool,number.boiler_hphystpool,6,0,5,229,1 +"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,silentmode,silent mode,enum [off\|auto\|on] (>=0<=0), ,true,select.boiler_silent_mode,select.boiler_silentmode,6,0,1,230,1 +"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,silentfrom,silent mode from,uint8 (>=0<=0),minutes,true,number.boiler_silent_mode_from,number.boiler_silentfrom,6,0,15,231,1 +"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,silentto,silent mode to,uint8 (>=0<=0),minutes,true,number.boiler_silent_mode_to,number.boiler_silentto,6,0,15,232,1 +"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,mintempsilent,min outside temp for silent mode,int8 (>=0<=0),C,true,number.boiler_min_outside_temp_for_silent_mode,number.boiler_mintempsilent,6,0,1,233,1 +"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,tempparmode,outside temp parallel mode,int8 (>=0<=0),C,true,number.boiler_outside_temp_parallel_mode,number.boiler_tempparmode,6,0,1,234,1 +"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,auxheatmix,aux heater mixing valve,int8,%,false,sensor.boiler_aux_heater_mixing_valve,sensor.boiler_auxheatmix,6,0,1,235,1 +"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,tempdiffheat,temp diff TC3/TC0 heat,uint8 (>=2<=10),K,true,number.boiler_temp_diff_TC3/TC0_heat,number.boiler_tempdiffheat,6,0,1/10,236,1 +"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,tempdiffcool,temp diff TC3/TC0 cool,uint8 (>=2<=10),K,true,number.boiler_temp_diff_TC3/TC0_cool,number.boiler_tempdiffcool,6,0,1/10,237,1 +"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,vpcooling,valve/pump cooling,boolean (>=0<=0), ,true,switch.boiler_valve/pump_cooling,switch.boiler_vpcooling,6,0,1,238,1 +"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,heatcable,heating cable,boolean (>=0<=0), ,true,switch.boiler_heating_cable,switch.boiler_heatcable,6,0,1,239,1 +"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,vc0valve,VC0 valve,boolean (>=0<=0), ,true,switch.boiler_VC0_valve,switch.boiler_vc0valve,6,0,1,240,1 +"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,primepump,primary heatpump,boolean (>=0<=0), ,true,switch.boiler_primary_heatpump,switch.boiler_primepump,6,0,1,241,1 +"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,primepumpmod,primary heatpump modulation,uint8 (>=0<=0),%,true,number.boiler_primary_heatpump_modulation,number.boiler_primepumpmod,6,0,1,242,1 +"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,hp3way,3-way valve,boolean (>=0<=0), ,true,switch.boiler_3-way_valve,switch.boiler_hp3way,6,0,1,243,1 +"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,elheatstep1,el. heater step 1,boolean (>=0<=0), ,true,switch.boiler_el._heater_step_1,switch.boiler_elheatstep1,6,0,1,244,1 +"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,elheatstep2,el. heater step 2,boolean (>=0<=0), ,true,switch.boiler_el._heater_step_2,switch.boiler_elheatstep2,6,0,1,245,1 +"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,elheatstep3,el. heater step 3,boolean (>=0<=0), ,true,switch.boiler_el._heater_step_3,switch.boiler_elheatstep3,6,0,1,246,1 +"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,hpea0,condensate reservoir heating (EA0),boolean, ,false,binary_sensor.boiler_condensate_reservoir_heating_(EA0),binary_sensor.boiler_hpea0,6,0,1,247,1 +"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,hppumpmode,primary heatpump mode,enum [auto\|continuous] (>=0<=0), ,true,select.boiler_primary_heatpump_mode,select.boiler_hppumpmode,6,0,1,248,1 +"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,fan,fan,uint8 (>=20<=100),%,true,number.boiler_fan,number.boiler_fan,6,0,1,249,1 +"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,fanspd,fan speed,uint8,%,false,sensor.boiler_fan_speed,sensor.boiler_fanspd,6,0,1,250,1 +"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,shutdown,shutdown,cmd [off\|on] (>=0<=0), ,true,sensor.boiler_shutdown,sensor.boiler_shutdown,6,0,1,251,1 +"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,hpcurrpower,compressor current power,uint16,W,false,sensor.boiler_compressor_current_power,sensor.boiler_hpcurrpower,6,0,1,252,1 +"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,hppowerlimit,power limit,uint16 (>=0<=0),W,true,number.boiler_power_limit,number.boiler_hppowerlimit,6,0,1,253,1 "CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,dhw.alternatingop,alternating operation,boolean (>=0<=0), ,true,switch.boiler_dhw_alternating_operation,switch.boiler_dhw_alternatingop,6,9,1,15,1 "CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,dhw.altopprioheat,prioritise heating during dhw,uint8 (>=20<=120),minutes,true,number.boiler_dhw_prioritise_heating_during_dhw,number.boiler_dhw_altopprioheat,6,9,1,16,1 "CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,dhw.altopprio,prioritise dhw during heating,uint8 (>=30<=120),minutes,true,number.boiler_dhw_prioritise_dhw_during_heating,number.boiler_dhw_altopprio,6,9,1,17,1 @@ -231,28 +232,28 @@ device name,device type,product id,shortname,fullname,type [options...] \| (min/ "Greenstar 2000",boiler,11,syspress,system pressure,uint8,bar,false,sensor.boiler_system_pressure,sensor.boiler_syspress,6,0,1/10,11,1 "Greenstar 2000",boiler,11,boiltemp,actual boiler temperature,uint16,C,false,sensor.boiler_actual_boiler_temperature,sensor.boiler_boiltemp,6,0,1/10,12,1 "Greenstar 2000",boiler,11,headertemp,low loss header,uint16,C,false,sensor.boiler_low_loss_header,sensor.boiler_headertemp,6,0,1/10,13,1 -"Greenstar 2000",boiler,11,exhausttemp,exhaust temperature,uint16,C,false,sensor.boiler_exhaust_temperature,sensor.boiler_exhausttemp,6,0,1/10,253,1 -"Greenstar 2000",boiler,11,burngas,gas,boolean, ,false,binary_sensor.boiler_gas,binary_sensor.boiler_burngas,6,0,1,254,1 -"Greenstar 2000",boiler,11,burngas2,gas stage 2,boolean, ,false,binary_sensor.boiler_gas_stage_2,binary_sensor.boiler_burngas2,6,0,1,255,1 -"Greenstar 2000",boiler,11,flamecurr,flame current,uint16,µA,false,sensor.boiler_flame_current,sensor.boiler_flamecurr,6,0,1/10,256,1 -"Greenstar 2000",boiler,11,fanwork,fan,boolean, ,false,binary_sensor.boiler_fan,binary_sensor.boiler_fanwork,6,0,1,257,1 -"Greenstar 2000",boiler,11,ignwork,ignition,boolean, ,false,binary_sensor.boiler_ignition,binary_sensor.boiler_ignwork,6,0,1,258,1 -"Greenstar 2000",boiler,11,oilpreheat,oil preheating,boolean, ,false,binary_sensor.boiler_oil_preheating,binary_sensor.boiler_oilpreheat,6,0,1,259,1 -"Greenstar 2000",boiler,11,burnminpower,burner min power,uint8 (>=0<=0),%,true,number.boiler_burner_min_power,number.boiler_burnminpower,6,0,1,260,1 -"Greenstar 2000",boiler,11,burnmaxpower,burner max power,uint8 (>=0<=254),%,true,number.boiler_burner_max_power,number.boiler_burnmaxpower,6,0,1,261,1 -"Greenstar 2000",boiler,11,burnminperiod,burner min period,uint8 (>=0<=120),minutes,true,number.boiler_burner_min_period,number.boiler_burnminperiod,6,0,1,262,1 -"Greenstar 2000",boiler,11,absburnpow,burner current power (absolute),uint8,%,false,sensor.boiler_burner_current_power_(absolute),sensor.boiler_absburnpow,6,0,1,263,1 -"Greenstar 2000",boiler,11,heatblock,Heatblock temperature,uint16,C,false,sensor.boiler_Heatblock_temperature,sensor.boiler_heatblock,6,0,1/10,264,1 -"Greenstar 2000",boiler,11,boilhyston,hysteresis on temperature,int8 (>=-20<=0),C,true,number.boiler_hysteresis_on_temperature,number.boiler_boilhyston,6,0,1,265,1 -"Greenstar 2000",boiler,11,boilhystoff,hysteresis off temperature,int8 (>=0<=20),C,true,number.boiler_hysteresis_off_temperature,number.boiler_boilhystoff,6,0,1,266,1 -"Greenstar 2000",boiler,11,boil2hyston,hysteresis stage 2 on temperature,int8 (>=-20<=0),C,true,number.boiler_hysteresis_stage_2_on_temperature,number.boiler_boil2hyston,6,0,1,267,1 -"Greenstar 2000",boiler,11,boil2hystoff,hysteresis stage 2 off temperature,int8 (>=0<=20),C,true,number.boiler_hysteresis_stage_2_off_temperature,number.boiler_boil2hystoff,6,0,1,268,1 -"Greenstar 2000",boiler,11,curveon,heatingcurve on,boolean (>=0<=0), ,true,switch.boiler_heatingcurve_on,switch.boiler_curveon,6,0,1,269,1 -"Greenstar 2000",boiler,11,curvebase,heatingcurve base,uint8 (>=20<=90),C,true,number.boiler_heatingcurve_base,number.boiler_curvebase,6,0,1,270,1 -"Greenstar 2000",boiler,11,curveend,heatingcurve end,uint8 (>=20<=90),C,true,number.boiler_heatingcurve_end,number.boiler_curveend,6,0,1,271,1 -"Greenstar 2000",boiler,11,summertemp,summer temperature,uint8 (>=0<=45),C,true,number.boiler_summer_temperature,number.boiler_summertemp,6,0,1,272,1 -"Greenstar 2000",boiler,11,nofrostmode,nofrost mode,boolean (>=0<=0), ,true,switch.boiler_nofrost_mode,switch.boiler_nofrostmode,6,0,1,273,1 -"Greenstar 2000",boiler,11,nofrosttemp,nofrost temperature,uint8 (>=0<=10),C,true,number.boiler_nofrost_temperature,number.boiler_nofrosttemp,6,0,1,274,1 +"Greenstar 2000",boiler,11,exhausttemp,exhaust temperature,uint16,C,false,sensor.boiler_exhaust_temperature,sensor.boiler_exhausttemp,6,0,1/10,254,1 +"Greenstar 2000",boiler,11,burngas,gas,boolean, ,false,binary_sensor.boiler_gas,binary_sensor.boiler_burngas,6,0,1,255,1 +"Greenstar 2000",boiler,11,burngas2,gas stage 2,boolean, ,false,binary_sensor.boiler_gas_stage_2,binary_sensor.boiler_burngas2,6,0,1,256,1 +"Greenstar 2000",boiler,11,flamecurr,flame current,uint16,µA,false,sensor.boiler_flame_current,sensor.boiler_flamecurr,6,0,1/10,257,1 +"Greenstar 2000",boiler,11,fanwork,fan,boolean, ,false,binary_sensor.boiler_fan,binary_sensor.boiler_fanwork,6,0,1,258,1 +"Greenstar 2000",boiler,11,ignwork,ignition,boolean, ,false,binary_sensor.boiler_ignition,binary_sensor.boiler_ignwork,6,0,1,259,1 +"Greenstar 2000",boiler,11,oilpreheat,oil preheating,boolean, ,false,binary_sensor.boiler_oil_preheating,binary_sensor.boiler_oilpreheat,6,0,1,260,1 +"Greenstar 2000",boiler,11,burnminpower,burner min power,uint8 (>=0<=0),%,true,number.boiler_burner_min_power,number.boiler_burnminpower,6,0,1,261,1 +"Greenstar 2000",boiler,11,burnmaxpower,burner max power,uint8 (>=0<=254),%,true,number.boiler_burner_max_power,number.boiler_burnmaxpower,6,0,1,262,1 +"Greenstar 2000",boiler,11,burnminperiod,burner min period,uint8 (>=0<=120),minutes,true,number.boiler_burner_min_period,number.boiler_burnminperiod,6,0,1,263,1 +"Greenstar 2000",boiler,11,absburnpow,burner current power (absolute),uint8,%,false,sensor.boiler_burner_current_power_(absolute),sensor.boiler_absburnpow,6,0,1,264,1 +"Greenstar 2000",boiler,11,heatblock,Heatblock temperature,uint16,C,false,sensor.boiler_Heatblock_temperature,sensor.boiler_heatblock,6,0,1/10,265,1 +"Greenstar 2000",boiler,11,boilhyston,hysteresis on temperature,int8 (>=-20<=0),C,true,number.boiler_hysteresis_on_temperature,number.boiler_boilhyston,6,0,1,266,1 +"Greenstar 2000",boiler,11,boilhystoff,hysteresis off temperature,int8 (>=0<=20),C,true,number.boiler_hysteresis_off_temperature,number.boiler_boilhystoff,6,0,1,267,1 +"Greenstar 2000",boiler,11,boil2hyston,hysteresis stage 2 on temperature,int8 (>=-20<=0),C,true,number.boiler_hysteresis_stage_2_on_temperature,number.boiler_boil2hyston,6,0,1,268,1 +"Greenstar 2000",boiler,11,boil2hystoff,hysteresis stage 2 off temperature,int8 (>=0<=20),C,true,number.boiler_hysteresis_stage_2_off_temperature,number.boiler_boil2hystoff,6,0,1,269,1 +"Greenstar 2000",boiler,11,curveon,heatingcurve on,boolean (>=0<=0), ,true,switch.boiler_heatingcurve_on,switch.boiler_curveon,6,0,1,270,1 +"Greenstar 2000",boiler,11,curvebase,heatingcurve base,uint8 (>=20<=90),C,true,number.boiler_heatingcurve_base,number.boiler_curvebase,6,0,1,271,1 +"Greenstar 2000",boiler,11,curveend,heatingcurve end,uint8 (>=20<=90),C,true,number.boiler_heatingcurve_end,number.boiler_curveend,6,0,1,272,1 +"Greenstar 2000",boiler,11,summertemp,summer temperature,uint8 (>=0<=45),C,true,number.boiler_summer_temperature,number.boiler_summertemp,6,0,1,273,1 +"Greenstar 2000",boiler,11,nofrostmode,nofrost mode,boolean (>=0<=0), ,true,switch.boiler_nofrost_mode,switch.boiler_nofrostmode,6,0,1,274,1 +"Greenstar 2000",boiler,11,nofrosttemp,nofrost temperature,uint8 (>=0<=10),C,true,number.boiler_nofrost_temperature,number.boiler_nofrosttemp,6,0,1,275,1 "Greenstar 2000",boiler,11,heatingactivated,heating activated,boolean (>=0<=0), ,true,switch.boiler_heating_activated,switch.boiler_heatingactivated,6,0,1,14,1 "Greenstar 2000",boiler,11,heatingtemp,heating temperature,uint8 (>=0<=90),C,true,number.boiler_heating_temperature,number.boiler_heatingtemp,6,0,1,15,1 "Greenstar 2000",boiler,11,heatingpump,heating pump,boolean, ,false,binary_sensor.boiler_heating_pump,binary_sensor.boiler_heatingpump,6,0,1,16,1 @@ -279,18 +280,19 @@ device name,device type,product id,shortname,fullname,type [options...] \| (min/ "Greenstar 2000",boiler,11,maintenancedate,next maintenance date,string (>=0<=0), ,true,sensor.boiler_next_maintenance_date,sensor.boiler_maintenancedate,6,0,1,72,6 "Greenstar 2000",boiler,11,emergencyops,emergency operation,boolean (>=0<=0), ,true,switch.boiler_emergency_operation,switch.boiler_emergencyops,6,0,1,78,1 "Greenstar 2000",boiler,11,emergencytemp,emergency temperature,uint8 (>=15<=70),C,true,number.boiler_emergency_temperature,number.boiler_emergencytemp,6,0,1,79,1 -"Greenstar 2000",boiler,11,pc0flow,Flow PC0,int16,l/h,false,sensor.boiler_Flow_PC0,sensor.boiler_pc0flow,6,0,1,80,1 -"Greenstar 2000",boiler,11,pc1flow,Flow PC1,int16,l/h,false,sensor.boiler_Flow_PC1,sensor.boiler_pc1flow,6,0,1,81,1 -"Greenstar 2000",boiler,11,pc1on,PC1,boolean, ,false,binary_sensor.boiler_PC1,binary_sensor.boiler_pc1on,6,0,1,82,1 -"Greenstar 2000",boiler,11,pc1rate,PC1 rate,uint8,%,false,sensor.boiler_PC1_rate,sensor.boiler_pc1rate,6,0,1,83,1 -"Greenstar 2000",boiler,11,pumpkickhour,pump kick hour,uint8 (>=0<=23),hours,true,number.boiler_pump_kick_hour,number.boiler_pumpkickhour,6,0,1,84,1 -"Greenstar 2000",boiler,11,pumpkickday,pump kick day,enum [mo\|tu\|we\|th\|fr\|sa\|su\|all] (>=0<=0), ,true,select.boiler_pump_kick_day,select.boiler_pumpkickday,6,0,1,85,1 -"Greenstar 2000",boiler,11,pumpkickdelay,pump kick delay,uint16 (>=0<=32767),minutes,true,number.boiler_pump_kick_delay,number.boiler_pumpkickdelay,6,0,1,86,1 -"Greenstar 2000",boiler,11,meterheat,meter heating,uint24,kWh,false,sensor.boiler_meter_heating,sensor.boiler_meterheat,6,0,1/10,100,2 +"Greenstar 2000",boiler,11,pc0lpm,Flow PC0,uint16,l/min,false,sensor.boiler_Flow_PC0,sensor.boiler_pc0lpm,6,0,1/10,80,1 +"Greenstar 2000",boiler,11,pc0flow,Flow PC0,uint16,l/h,false,sensor.boiler_Flow_PC0,sensor.boiler_pc0flow,6,0,1,81,1 +"Greenstar 2000",boiler,11,pc1flow,Flow PC1,uint16,l/h,false,sensor.boiler_Flow_PC1,sensor.boiler_pc1flow,6,0,1,82,1 +"Greenstar 2000",boiler,11,pc1on,PC1,boolean, ,false,binary_sensor.boiler_PC1,binary_sensor.boiler_pc1on,6,0,1,83,1 +"Greenstar 2000",boiler,11,pc1rate,PC1 rate,uint8,%,false,sensor.boiler_PC1_rate,sensor.boiler_pc1rate,6,0,1,84,1 +"Greenstar 2000",boiler,11,pumpkickhour,pump kick hour,uint8 (>=0<=23),hours,true,number.boiler_pump_kick_hour,number.boiler_pumpkickhour,6,0,1,85,1 +"Greenstar 2000",boiler,11,pumpkickday,pump kick day,enum [mo\|tu\|we\|th\|fr\|sa\|su\|all] (>=0<=0), ,true,select.boiler_pump_kick_day,select.boiler_pumpkickday,6,0,1,86,1 +"Greenstar 2000",boiler,11,pumpkickdelay,pump kick delay,uint16 (>=0<=32767),minutes,true,number.boiler_pump_kick_delay,number.boiler_pumpkickdelay,6,0,1,87,1 +"Greenstar 2000",boiler,11,meterheat,meter heating,uint24,kWh,false,sensor.boiler_meter_heating,sensor.boiler_meterheat,6,0,1/10,101,2 "Greenstar 2000",boiler,11,dhw.meter,meter,uint24,kWh,false,sensor.boiler_dhw_meter,sensor.boiler_dhw_meter,6,9,1/10,2,2 -"Greenstar 2000",boiler,11,gasmeterheat,gas meter heating,uint24,kWh,false,sensor.boiler_gas_meter_heating,sensor.boiler_gasmeterheat,6,0,1/10,275,2 +"Greenstar 2000",boiler,11,gasmeterheat,gas meter heating,uint24,kWh,false,sensor.boiler_gas_meter_heating,sensor.boiler_gasmeterheat,6,0,1/10,276,2 "Greenstar 2000",boiler,11,dhw.gasmeter,gas meter,uint24,kWh,false,sensor.boiler_dhw_gas_meter,sensor.boiler_dhw_gasmeter,6,9,1/10,71,2 -"Greenstar 2000",boiler,11,nrgheat2,energy heating 2,uint24,kWh,false,sensor.boiler_energy_heating_2,sensor.boiler_nrgheat2,6,0,1/10,277,2 +"Greenstar 2000",boiler,11,nrgheat2,energy heating 2,uint24,kWh,false,sensor.boiler_energy_heating_2,sensor.boiler_nrgheat2,6,0,1/10,278,2 "Greenstar 2000",boiler,11,dhw.nrg2,energy 2,uint24,kWh,false,sensor.boiler_dhw_energy_2,sensor.boiler_dhw_nrg2,6,9,1/10,73,2 "Greenstar 2000",boiler,11,dhw.tapactivated,turn on/off,boolean (>=0<=0), ,true,switch.boiler_dhw_turn_on/off,switch.boiler_dhw_tapactivated,6,9,1,28,1 "Greenstar 2000",boiler,11,dhw.settemp,set temperature,uint8,C,false,sensor.boiler_dhw_set_temperature,sensor.boiler_dhw_settemp,6,9,1,29,1 @@ -333,9 +335,9 @@ device name,device type,product id,shortname,fullname,type [options...] \| (min/ "Greenstar 2000",boiler,11,dhw.dhwprio,dhw priority,boolean (>=0<=0), ,true,switch.boiler_dhw_dhw_priority,switch.boiler_dhw_dhwprio,6,9,1,66,1 "Greenstar 2000",boiler,11,dhw.starts,starts,uint24, ,false,sensor.boiler_dhw_starts,sensor.boiler_dhw_starts,6,9,1,67,2 "Greenstar 2000",boiler,11,dhw.workm,active time,time,minutes,false,sensor.boiler_dhw_active_time,sensor.boiler_dhw_workm,6,9,1,69,2 -"Greenstar 2000",boiler,11,nompower,nominal Power,uint8 (>=0<=0),kW,true,number.boiler_nominal_Power,number.boiler_nompower,6,0,1,279,1 -"Greenstar 2000",boiler,11,nrgtotal,total energy,uint24,kWh,false,sensor.boiler_total_energy,sensor.boiler_nrgtotal,6,0,1/100,88,2 -"Greenstar 2000",boiler,11,nrgheat,energy heating,uint24 (>=0<=10000000),kWh,true,number.boiler_energy_heating,number.boiler_nrgheat,6,0,1/100,90,2 +"Greenstar 2000",boiler,11,nompower,nominal Power,uint8 (>=0<=0),kW,true,number.boiler_nominal_Power,number.boiler_nompower,6,0,1,280,1 +"Greenstar 2000",boiler,11,nrgtotal,total energy,uint24,kWh,false,sensor.boiler_total_energy,sensor.boiler_nrgtotal,6,0,1/100,89,2 +"Greenstar 2000",boiler,11,nrgheat,energy heating,uint24 (>=0<=10000000),kWh,true,number.boiler_energy_heating,number.boiler_nrgheat,6,0,1/100,91,2 "Greenstar 2000",boiler,11,dhw.nrg,energy,uint24 (>=0<=10000000),kWh,true,number.boiler_dhw_energy,number.boiler_dhw_nrg,6,9,1/100,0,2 "C1200W",boiler,12,reset,reset,cmd [-\|maintenance\|error\|history\|message\|hp error\|burner starts\|factory] (>=0<=0), ,true,sensor.boiler_reset,sensor.boiler_reset,6,0,1,0,1 "C1200W",boiler,12,chimneysweeper,chimney sweeper,cmd [off\|on] (>=0<=0), ,true,sensor.boiler_chimney_sweeper,sensor.boiler_chimneysweeper,6,0,1,1,1 @@ -351,28 +353,28 @@ device name,device type,product id,shortname,fullname,type [options...] \| (min/ "C1200W",boiler,12,syspress,system pressure,uint8,bar,false,sensor.boiler_system_pressure,sensor.boiler_syspress,6,0,1/10,11,1 "C1200W",boiler,12,boiltemp,actual boiler temperature,uint16,C,false,sensor.boiler_actual_boiler_temperature,sensor.boiler_boiltemp,6,0,1/10,12,1 "C1200W",boiler,12,headertemp,low loss header,uint16,C,false,sensor.boiler_low_loss_header,sensor.boiler_headertemp,6,0,1/10,13,1 -"C1200W",boiler,12,exhausttemp,exhaust temperature,uint16,C,false,sensor.boiler_exhaust_temperature,sensor.boiler_exhausttemp,6,0,1/10,253,1 -"C1200W",boiler,12,burngas,gas,boolean, ,false,binary_sensor.boiler_gas,binary_sensor.boiler_burngas,6,0,1,254,1 -"C1200W",boiler,12,burngas2,gas stage 2,boolean, ,false,binary_sensor.boiler_gas_stage_2,binary_sensor.boiler_burngas2,6,0,1,255,1 -"C1200W",boiler,12,flamecurr,flame current,uint16,µA,false,sensor.boiler_flame_current,sensor.boiler_flamecurr,6,0,1/10,256,1 -"C1200W",boiler,12,fanwork,fan,boolean, ,false,binary_sensor.boiler_fan,binary_sensor.boiler_fanwork,6,0,1,257,1 -"C1200W",boiler,12,ignwork,ignition,boolean, ,false,binary_sensor.boiler_ignition,binary_sensor.boiler_ignwork,6,0,1,258,1 -"C1200W",boiler,12,oilpreheat,oil preheating,boolean, ,false,binary_sensor.boiler_oil_preheating,binary_sensor.boiler_oilpreheat,6,0,1,259,1 -"C1200W",boiler,12,burnminpower,burner min power,uint8 (>=0<=0),%,true,number.boiler_burner_min_power,number.boiler_burnminpower,6,0,1,260,1 -"C1200W",boiler,12,burnmaxpower,burner max power,uint8 (>=0<=254),%,true,number.boiler_burner_max_power,number.boiler_burnmaxpower,6,0,1,261,1 -"C1200W",boiler,12,burnminperiod,burner min period,uint8 (>=0<=120),minutes,true,number.boiler_burner_min_period,number.boiler_burnminperiod,6,0,1,262,1 -"C1200W",boiler,12,absburnpow,burner current power (absolute),uint8,%,false,sensor.boiler_burner_current_power_(absolute),sensor.boiler_absburnpow,6,0,1,263,1 -"C1200W",boiler,12,heatblock,Heatblock temperature,uint16,C,false,sensor.boiler_Heatblock_temperature,sensor.boiler_heatblock,6,0,1/10,264,1 -"C1200W",boiler,12,boilhyston,hysteresis on temperature,int8 (>=-20<=0),C,true,number.boiler_hysteresis_on_temperature,number.boiler_boilhyston,6,0,1,265,1 -"C1200W",boiler,12,boilhystoff,hysteresis off temperature,int8 (>=0<=20),C,true,number.boiler_hysteresis_off_temperature,number.boiler_boilhystoff,6,0,1,266,1 -"C1200W",boiler,12,boil2hyston,hysteresis stage 2 on temperature,int8 (>=-20<=0),C,true,number.boiler_hysteresis_stage_2_on_temperature,number.boiler_boil2hyston,6,0,1,267,1 -"C1200W",boiler,12,boil2hystoff,hysteresis stage 2 off temperature,int8 (>=0<=20),C,true,number.boiler_hysteresis_stage_2_off_temperature,number.boiler_boil2hystoff,6,0,1,268,1 -"C1200W",boiler,12,curveon,heatingcurve on,boolean (>=0<=0), ,true,switch.boiler_heatingcurve_on,switch.boiler_curveon,6,0,1,269,1 -"C1200W",boiler,12,curvebase,heatingcurve base,uint8 (>=20<=90),C,true,number.boiler_heatingcurve_base,number.boiler_curvebase,6,0,1,270,1 -"C1200W",boiler,12,curveend,heatingcurve end,uint8 (>=20<=90),C,true,number.boiler_heatingcurve_end,number.boiler_curveend,6,0,1,271,1 -"C1200W",boiler,12,summertemp,summer temperature,uint8 (>=0<=45),C,true,number.boiler_summer_temperature,number.boiler_summertemp,6,0,1,272,1 -"C1200W",boiler,12,nofrostmode,nofrost mode,boolean (>=0<=0), ,true,switch.boiler_nofrost_mode,switch.boiler_nofrostmode,6,0,1,273,1 -"C1200W",boiler,12,nofrosttemp,nofrost temperature,uint8 (>=0<=10),C,true,number.boiler_nofrost_temperature,number.boiler_nofrosttemp,6,0,1,274,1 +"C1200W",boiler,12,exhausttemp,exhaust temperature,uint16,C,false,sensor.boiler_exhaust_temperature,sensor.boiler_exhausttemp,6,0,1/10,254,1 +"C1200W",boiler,12,burngas,gas,boolean, ,false,binary_sensor.boiler_gas,binary_sensor.boiler_burngas,6,0,1,255,1 +"C1200W",boiler,12,burngas2,gas stage 2,boolean, ,false,binary_sensor.boiler_gas_stage_2,binary_sensor.boiler_burngas2,6,0,1,256,1 +"C1200W",boiler,12,flamecurr,flame current,uint16,µA,false,sensor.boiler_flame_current,sensor.boiler_flamecurr,6,0,1/10,257,1 +"C1200W",boiler,12,fanwork,fan,boolean, ,false,binary_sensor.boiler_fan,binary_sensor.boiler_fanwork,6,0,1,258,1 +"C1200W",boiler,12,ignwork,ignition,boolean, ,false,binary_sensor.boiler_ignition,binary_sensor.boiler_ignwork,6,0,1,259,1 +"C1200W",boiler,12,oilpreheat,oil preheating,boolean, ,false,binary_sensor.boiler_oil_preheating,binary_sensor.boiler_oilpreheat,6,0,1,260,1 +"C1200W",boiler,12,burnminpower,burner min power,uint8 (>=0<=0),%,true,number.boiler_burner_min_power,number.boiler_burnminpower,6,0,1,261,1 +"C1200W",boiler,12,burnmaxpower,burner max power,uint8 (>=0<=254),%,true,number.boiler_burner_max_power,number.boiler_burnmaxpower,6,0,1,262,1 +"C1200W",boiler,12,burnminperiod,burner min period,uint8 (>=0<=120),minutes,true,number.boiler_burner_min_period,number.boiler_burnminperiod,6,0,1,263,1 +"C1200W",boiler,12,absburnpow,burner current power (absolute),uint8,%,false,sensor.boiler_burner_current_power_(absolute),sensor.boiler_absburnpow,6,0,1,264,1 +"C1200W",boiler,12,heatblock,Heatblock temperature,uint16,C,false,sensor.boiler_Heatblock_temperature,sensor.boiler_heatblock,6,0,1/10,265,1 +"C1200W",boiler,12,boilhyston,hysteresis on temperature,int8 (>=-20<=0),C,true,number.boiler_hysteresis_on_temperature,number.boiler_boilhyston,6,0,1,266,1 +"C1200W",boiler,12,boilhystoff,hysteresis off temperature,int8 (>=0<=20),C,true,number.boiler_hysteresis_off_temperature,number.boiler_boilhystoff,6,0,1,267,1 +"C1200W",boiler,12,boil2hyston,hysteresis stage 2 on temperature,int8 (>=-20<=0),C,true,number.boiler_hysteresis_stage_2_on_temperature,number.boiler_boil2hyston,6,0,1,268,1 +"C1200W",boiler,12,boil2hystoff,hysteresis stage 2 off temperature,int8 (>=0<=20),C,true,number.boiler_hysteresis_stage_2_off_temperature,number.boiler_boil2hystoff,6,0,1,269,1 +"C1200W",boiler,12,curveon,heatingcurve on,boolean (>=0<=0), ,true,switch.boiler_heatingcurve_on,switch.boiler_curveon,6,0,1,270,1 +"C1200W",boiler,12,curvebase,heatingcurve base,uint8 (>=20<=90),C,true,number.boiler_heatingcurve_base,number.boiler_curvebase,6,0,1,271,1 +"C1200W",boiler,12,curveend,heatingcurve end,uint8 (>=20<=90),C,true,number.boiler_heatingcurve_end,number.boiler_curveend,6,0,1,272,1 +"C1200W",boiler,12,summertemp,summer temperature,uint8 (>=0<=45),C,true,number.boiler_summer_temperature,number.boiler_summertemp,6,0,1,273,1 +"C1200W",boiler,12,nofrostmode,nofrost mode,boolean (>=0<=0), ,true,switch.boiler_nofrost_mode,switch.boiler_nofrostmode,6,0,1,274,1 +"C1200W",boiler,12,nofrosttemp,nofrost temperature,uint8 (>=0<=10),C,true,number.boiler_nofrost_temperature,number.boiler_nofrosttemp,6,0,1,275,1 "C1200W",boiler,12,heatingactivated,heating activated,boolean (>=0<=0), ,true,switch.boiler_heating_activated,switch.boiler_heatingactivated,6,0,1,14,1 "C1200W",boiler,12,heatingtemp,heating temperature,uint8 (>=0<=90),C,true,number.boiler_heating_temperature,number.boiler_heatingtemp,6,0,1,15,1 "C1200W",boiler,12,heatingpump,heating pump,boolean, ,false,binary_sensor.boiler_heating_pump,binary_sensor.boiler_heatingpump,6,0,1,16,1 @@ -399,18 +401,19 @@ device name,device type,product id,shortname,fullname,type [options...] \| (min/ "C1200W",boiler,12,maintenancedate,next maintenance date,string (>=0<=0), ,true,sensor.boiler_next_maintenance_date,sensor.boiler_maintenancedate,6,0,1,72,6 "C1200W",boiler,12,emergencyops,emergency operation,boolean (>=0<=0), ,true,switch.boiler_emergency_operation,switch.boiler_emergencyops,6,0,1,78,1 "C1200W",boiler,12,emergencytemp,emergency temperature,uint8 (>=15<=70),C,true,number.boiler_emergency_temperature,number.boiler_emergencytemp,6,0,1,79,1 -"C1200W",boiler,12,pc0flow,Flow PC0,int16,l/h,false,sensor.boiler_Flow_PC0,sensor.boiler_pc0flow,6,0,1,80,1 -"C1200W",boiler,12,pc1flow,Flow PC1,int16,l/h,false,sensor.boiler_Flow_PC1,sensor.boiler_pc1flow,6,0,1,81,1 -"C1200W",boiler,12,pc1on,PC1,boolean, ,false,binary_sensor.boiler_PC1,binary_sensor.boiler_pc1on,6,0,1,82,1 -"C1200W",boiler,12,pc1rate,PC1 rate,uint8,%,false,sensor.boiler_PC1_rate,sensor.boiler_pc1rate,6,0,1,83,1 -"C1200W",boiler,12,pumpkickhour,pump kick hour,uint8 (>=0<=23),hours,true,number.boiler_pump_kick_hour,number.boiler_pumpkickhour,6,0,1,84,1 -"C1200W",boiler,12,pumpkickday,pump kick day,enum [mo\|tu\|we\|th\|fr\|sa\|su\|all] (>=0<=0), ,true,select.boiler_pump_kick_day,select.boiler_pumpkickday,6,0,1,85,1 -"C1200W",boiler,12,pumpkickdelay,pump kick delay,uint16 (>=0<=32767),minutes,true,number.boiler_pump_kick_delay,number.boiler_pumpkickdelay,6,0,1,86,1 -"C1200W",boiler,12,meterheat,meter heating,uint24,kWh,false,sensor.boiler_meter_heating,sensor.boiler_meterheat,6,0,1/10,100,2 +"C1200W",boiler,12,pc0lpm,Flow PC0,uint16,l/min,false,sensor.boiler_Flow_PC0,sensor.boiler_pc0lpm,6,0,1/10,80,1 +"C1200W",boiler,12,pc0flow,Flow PC0,uint16,l/h,false,sensor.boiler_Flow_PC0,sensor.boiler_pc0flow,6,0,1,81,1 +"C1200W",boiler,12,pc1flow,Flow PC1,uint16,l/h,false,sensor.boiler_Flow_PC1,sensor.boiler_pc1flow,6,0,1,82,1 +"C1200W",boiler,12,pc1on,PC1,boolean, ,false,binary_sensor.boiler_PC1,binary_sensor.boiler_pc1on,6,0,1,83,1 +"C1200W",boiler,12,pc1rate,PC1 rate,uint8,%,false,sensor.boiler_PC1_rate,sensor.boiler_pc1rate,6,0,1,84,1 +"C1200W",boiler,12,pumpkickhour,pump kick hour,uint8 (>=0<=23),hours,true,number.boiler_pump_kick_hour,number.boiler_pumpkickhour,6,0,1,85,1 +"C1200W",boiler,12,pumpkickday,pump kick day,enum [mo\|tu\|we\|th\|fr\|sa\|su\|all] (>=0<=0), ,true,select.boiler_pump_kick_day,select.boiler_pumpkickday,6,0,1,86,1 +"C1200W",boiler,12,pumpkickdelay,pump kick delay,uint16 (>=0<=32767),minutes,true,number.boiler_pump_kick_delay,number.boiler_pumpkickdelay,6,0,1,87,1 +"C1200W",boiler,12,meterheat,meter heating,uint24,kWh,false,sensor.boiler_meter_heating,sensor.boiler_meterheat,6,0,1/10,101,2 "C1200W",boiler,12,dhw.meter,meter,uint24,kWh,false,sensor.boiler_dhw_meter,sensor.boiler_dhw_meter,6,9,1/10,2,2 -"C1200W",boiler,12,gasmeterheat,gas meter heating,uint24,kWh,false,sensor.boiler_gas_meter_heating,sensor.boiler_gasmeterheat,6,0,1/10,275,2 +"C1200W",boiler,12,gasmeterheat,gas meter heating,uint24,kWh,false,sensor.boiler_gas_meter_heating,sensor.boiler_gasmeterheat,6,0,1/10,276,2 "C1200W",boiler,12,dhw.gasmeter,gas meter,uint24,kWh,false,sensor.boiler_dhw_gas_meter,sensor.boiler_dhw_gasmeter,6,9,1/10,71,2 -"C1200W",boiler,12,nrgheat2,energy heating 2,uint24,kWh,false,sensor.boiler_energy_heating_2,sensor.boiler_nrgheat2,6,0,1/10,277,2 +"C1200W",boiler,12,nrgheat2,energy heating 2,uint24,kWh,false,sensor.boiler_energy_heating_2,sensor.boiler_nrgheat2,6,0,1/10,278,2 "C1200W",boiler,12,dhw.nrg2,energy 2,uint24,kWh,false,sensor.boiler_dhw_energy_2,sensor.boiler_dhw_nrg2,6,9,1/10,73,2 "C1200W",boiler,12,dhw.tapactivated,turn on/off,boolean (>=0<=0), ,true,switch.boiler_dhw_turn_on/off,switch.boiler_dhw_tapactivated,6,9,1,28,1 "C1200W",boiler,12,dhw.settemp,set temperature,uint8,C,false,sensor.boiler_dhw_set_temperature,sensor.boiler_dhw_settemp,6,9,1,29,1 @@ -453,9 +456,9 @@ device name,device type,product id,shortname,fullname,type [options...] \| (min/ "C1200W",boiler,12,dhw.dhwprio,dhw priority,boolean (>=0<=0), ,true,switch.boiler_dhw_dhw_priority,switch.boiler_dhw_dhwprio,6,9,1,66,1 "C1200W",boiler,12,dhw.starts,starts,uint24, ,false,sensor.boiler_dhw_starts,sensor.boiler_dhw_starts,6,9,1,67,2 "C1200W",boiler,12,dhw.workm,active time,time,minutes,false,sensor.boiler_dhw_active_time,sensor.boiler_dhw_workm,6,9,1,69,2 -"C1200W",boiler,12,nompower,nominal Power,uint8 (>=0<=0),kW,true,number.boiler_nominal_Power,number.boiler_nompower,6,0,1,279,1 -"C1200W",boiler,12,nrgtotal,total energy,uint24,kWh,false,sensor.boiler_total_energy,sensor.boiler_nrgtotal,6,0,1/100,88,2 -"C1200W",boiler,12,nrgheat,energy heating,uint24 (>=0<=10000000),kWh,true,number.boiler_energy_heating,number.boiler_nrgheat,6,0,1/100,90,2 +"C1200W",boiler,12,nompower,nominal Power,uint8 (>=0<=0),kW,true,number.boiler_nominal_Power,number.boiler_nompower,6,0,1,280,1 +"C1200W",boiler,12,nrgtotal,total energy,uint24,kWh,false,sensor.boiler_total_energy,sensor.boiler_nrgtotal,6,0,1/100,89,2 +"C1200W",boiler,12,nrgheat,energy heating,uint24 (>=0<=10000000),kWh,true,number.boiler_energy_heating,number.boiler_nrgheat,6,0,1/100,91,2 "C1200W",boiler,12,dhw.nrg,energy,uint24 (>=0<=10000000),kWh,true,number.boiler_dhw_energy,number.boiler_dhw_nrg,6,9,1/100,0,2 "CS5800iG",boiler,16,reset,reset,cmd [-\|maintenance\|error\|history\|message\|hp error\|burner starts\|factory] (>=0<=0), ,true,sensor.boiler_reset,sensor.boiler_reset,6,0,1,0,1 "CS5800iG",boiler,16,chimneysweeper,chimney sweeper,cmd [off\|on] (>=0<=0), ,true,sensor.boiler_chimney_sweeper,sensor.boiler_chimneysweeper,6,0,1,1,1 @@ -471,28 +474,28 @@ device name,device type,product id,shortname,fullname,type [options...] \| (min/ "CS5800iG",boiler,16,syspress,system pressure,uint8,bar,false,sensor.boiler_system_pressure,sensor.boiler_syspress,6,0,1/10,11,1 "CS5800iG",boiler,16,boiltemp,actual boiler temperature,uint16,C,false,sensor.boiler_actual_boiler_temperature,sensor.boiler_boiltemp,6,0,1/10,12,1 "CS5800iG",boiler,16,headertemp,low loss header,uint16,C,false,sensor.boiler_low_loss_header,sensor.boiler_headertemp,6,0,1/10,13,1 -"CS5800iG",boiler,16,exhausttemp,exhaust temperature,uint16,C,false,sensor.boiler_exhaust_temperature,sensor.boiler_exhausttemp,6,0,1/10,253,1 -"CS5800iG",boiler,16,burngas,gas,boolean, ,false,binary_sensor.boiler_gas,binary_sensor.boiler_burngas,6,0,1,254,1 -"CS5800iG",boiler,16,burngas2,gas stage 2,boolean, ,false,binary_sensor.boiler_gas_stage_2,binary_sensor.boiler_burngas2,6,0,1,255,1 -"CS5800iG",boiler,16,flamecurr,flame current,uint16,µA,false,sensor.boiler_flame_current,sensor.boiler_flamecurr,6,0,1/10,256,1 -"CS5800iG",boiler,16,fanwork,fan,boolean, ,false,binary_sensor.boiler_fan,binary_sensor.boiler_fanwork,6,0,1,257,1 -"CS5800iG",boiler,16,ignwork,ignition,boolean, ,false,binary_sensor.boiler_ignition,binary_sensor.boiler_ignwork,6,0,1,258,1 -"CS5800iG",boiler,16,oilpreheat,oil preheating,boolean, ,false,binary_sensor.boiler_oil_preheating,binary_sensor.boiler_oilpreheat,6,0,1,259,1 -"CS5800iG",boiler,16,burnminpower,burner min power,uint8 (>=0<=0),%,true,number.boiler_burner_min_power,number.boiler_burnminpower,6,0,1,260,1 -"CS5800iG",boiler,16,burnmaxpower,burner max power,uint8 (>=0<=254),%,true,number.boiler_burner_max_power,number.boiler_burnmaxpower,6,0,1,261,1 -"CS5800iG",boiler,16,burnminperiod,burner min period,uint8 (>=0<=120),minutes,true,number.boiler_burner_min_period,number.boiler_burnminperiod,6,0,1,262,1 -"CS5800iG",boiler,16,absburnpow,burner current power (absolute),uint8,%,false,sensor.boiler_burner_current_power_(absolute),sensor.boiler_absburnpow,6,0,1,263,1 -"CS5800iG",boiler,16,heatblock,Heatblock temperature,uint16,C,false,sensor.boiler_Heatblock_temperature,sensor.boiler_heatblock,6,0,1/10,264,1 -"CS5800iG",boiler,16,boilhyston,hysteresis on temperature,int8 (>=-20<=0),C,true,number.boiler_hysteresis_on_temperature,number.boiler_boilhyston,6,0,1,265,1 -"CS5800iG",boiler,16,boilhystoff,hysteresis off temperature,int8 (>=0<=20),C,true,number.boiler_hysteresis_off_temperature,number.boiler_boilhystoff,6,0,1,266,1 -"CS5800iG",boiler,16,boil2hyston,hysteresis stage 2 on temperature,int8 (>=-20<=0),C,true,number.boiler_hysteresis_stage_2_on_temperature,number.boiler_boil2hyston,6,0,1,267,1 -"CS5800iG",boiler,16,boil2hystoff,hysteresis stage 2 off temperature,int8 (>=0<=20),C,true,number.boiler_hysteresis_stage_2_off_temperature,number.boiler_boil2hystoff,6,0,1,268,1 -"CS5800iG",boiler,16,curveon,heatingcurve on,boolean (>=0<=0), ,true,switch.boiler_heatingcurve_on,switch.boiler_curveon,6,0,1,269,1 -"CS5800iG",boiler,16,curvebase,heatingcurve base,uint8 (>=20<=90),C,true,number.boiler_heatingcurve_base,number.boiler_curvebase,6,0,1,270,1 -"CS5800iG",boiler,16,curveend,heatingcurve end,uint8 (>=20<=90),C,true,number.boiler_heatingcurve_end,number.boiler_curveend,6,0,1,271,1 -"CS5800iG",boiler,16,summertemp,summer temperature,uint8 (>=0<=45),C,true,number.boiler_summer_temperature,number.boiler_summertemp,6,0,1,272,1 -"CS5800iG",boiler,16,nofrostmode,nofrost mode,boolean (>=0<=0), ,true,switch.boiler_nofrost_mode,switch.boiler_nofrostmode,6,0,1,273,1 -"CS5800iG",boiler,16,nofrosttemp,nofrost temperature,uint8 (>=0<=10),C,true,number.boiler_nofrost_temperature,number.boiler_nofrosttemp,6,0,1,274,1 +"CS5800iG",boiler,16,exhausttemp,exhaust temperature,uint16,C,false,sensor.boiler_exhaust_temperature,sensor.boiler_exhausttemp,6,0,1/10,254,1 +"CS5800iG",boiler,16,burngas,gas,boolean, ,false,binary_sensor.boiler_gas,binary_sensor.boiler_burngas,6,0,1,255,1 +"CS5800iG",boiler,16,burngas2,gas stage 2,boolean, ,false,binary_sensor.boiler_gas_stage_2,binary_sensor.boiler_burngas2,6,0,1,256,1 +"CS5800iG",boiler,16,flamecurr,flame current,uint16,µA,false,sensor.boiler_flame_current,sensor.boiler_flamecurr,6,0,1/10,257,1 +"CS5800iG",boiler,16,fanwork,fan,boolean, ,false,binary_sensor.boiler_fan,binary_sensor.boiler_fanwork,6,0,1,258,1 +"CS5800iG",boiler,16,ignwork,ignition,boolean, ,false,binary_sensor.boiler_ignition,binary_sensor.boiler_ignwork,6,0,1,259,1 +"CS5800iG",boiler,16,oilpreheat,oil preheating,boolean, ,false,binary_sensor.boiler_oil_preheating,binary_sensor.boiler_oilpreheat,6,0,1,260,1 +"CS5800iG",boiler,16,burnminpower,burner min power,uint8 (>=0<=0),%,true,number.boiler_burner_min_power,number.boiler_burnminpower,6,0,1,261,1 +"CS5800iG",boiler,16,burnmaxpower,burner max power,uint8 (>=0<=254),%,true,number.boiler_burner_max_power,number.boiler_burnmaxpower,6,0,1,262,1 +"CS5800iG",boiler,16,burnminperiod,burner min period,uint8 (>=0<=120),minutes,true,number.boiler_burner_min_period,number.boiler_burnminperiod,6,0,1,263,1 +"CS5800iG",boiler,16,absburnpow,burner current power (absolute),uint8,%,false,sensor.boiler_burner_current_power_(absolute),sensor.boiler_absburnpow,6,0,1,264,1 +"CS5800iG",boiler,16,heatblock,Heatblock temperature,uint16,C,false,sensor.boiler_Heatblock_temperature,sensor.boiler_heatblock,6,0,1/10,265,1 +"CS5800iG",boiler,16,boilhyston,hysteresis on temperature,int8 (>=-20<=0),C,true,number.boiler_hysteresis_on_temperature,number.boiler_boilhyston,6,0,1,266,1 +"CS5800iG",boiler,16,boilhystoff,hysteresis off temperature,int8 (>=0<=20),C,true,number.boiler_hysteresis_off_temperature,number.boiler_boilhystoff,6,0,1,267,1 +"CS5800iG",boiler,16,boil2hyston,hysteresis stage 2 on temperature,int8 (>=-20<=0),C,true,number.boiler_hysteresis_stage_2_on_temperature,number.boiler_boil2hyston,6,0,1,268,1 +"CS5800iG",boiler,16,boil2hystoff,hysteresis stage 2 off temperature,int8 (>=0<=20),C,true,number.boiler_hysteresis_stage_2_off_temperature,number.boiler_boil2hystoff,6,0,1,269,1 +"CS5800iG",boiler,16,curveon,heatingcurve on,boolean (>=0<=0), ,true,switch.boiler_heatingcurve_on,switch.boiler_curveon,6,0,1,270,1 +"CS5800iG",boiler,16,curvebase,heatingcurve base,uint8 (>=20<=90),C,true,number.boiler_heatingcurve_base,number.boiler_curvebase,6,0,1,271,1 +"CS5800iG",boiler,16,curveend,heatingcurve end,uint8 (>=20<=90),C,true,number.boiler_heatingcurve_end,number.boiler_curveend,6,0,1,272,1 +"CS5800iG",boiler,16,summertemp,summer temperature,uint8 (>=0<=45),C,true,number.boiler_summer_temperature,number.boiler_summertemp,6,0,1,273,1 +"CS5800iG",boiler,16,nofrostmode,nofrost mode,boolean (>=0<=0), ,true,switch.boiler_nofrost_mode,switch.boiler_nofrostmode,6,0,1,274,1 +"CS5800iG",boiler,16,nofrosttemp,nofrost temperature,uint8 (>=0<=10),C,true,number.boiler_nofrost_temperature,number.boiler_nofrosttemp,6,0,1,275,1 "CS5800iG",boiler,16,heatingactivated,heating activated,boolean (>=0<=0), ,true,switch.boiler_heating_activated,switch.boiler_heatingactivated,6,0,1,14,1 "CS5800iG",boiler,16,heatingtemp,heating temperature,uint8 (>=0<=90),C,true,number.boiler_heating_temperature,number.boiler_heatingtemp,6,0,1,15,1 "CS5800iG",boiler,16,heatingpump,heating pump,boolean, ,false,binary_sensor.boiler_heating_pump,binary_sensor.boiler_heatingpump,6,0,1,16,1 @@ -519,18 +522,19 @@ device name,device type,product id,shortname,fullname,type [options...] \| (min/ "CS5800iG",boiler,16,maintenancedate,next maintenance date,string (>=0<=0), ,true,sensor.boiler_next_maintenance_date,sensor.boiler_maintenancedate,6,0,1,72,6 "CS5800iG",boiler,16,emergencyops,emergency operation,boolean (>=0<=0), ,true,switch.boiler_emergency_operation,switch.boiler_emergencyops,6,0,1,78,1 "CS5800iG",boiler,16,emergencytemp,emergency temperature,uint8 (>=15<=70),C,true,number.boiler_emergency_temperature,number.boiler_emergencytemp,6,0,1,79,1 -"CS5800iG",boiler,16,pc0flow,Flow PC0,int16,l/h,false,sensor.boiler_Flow_PC0,sensor.boiler_pc0flow,6,0,1,80,1 -"CS5800iG",boiler,16,pc1flow,Flow PC1,int16,l/h,false,sensor.boiler_Flow_PC1,sensor.boiler_pc1flow,6,0,1,81,1 -"CS5800iG",boiler,16,pc1on,PC1,boolean, ,false,binary_sensor.boiler_PC1,binary_sensor.boiler_pc1on,6,0,1,82,1 -"CS5800iG",boiler,16,pc1rate,PC1 rate,uint8,%,false,sensor.boiler_PC1_rate,sensor.boiler_pc1rate,6,0,1,83,1 -"CS5800iG",boiler,16,pumpkickhour,pump kick hour,uint8 (>=0<=23),hours,true,number.boiler_pump_kick_hour,number.boiler_pumpkickhour,6,0,1,84,1 -"CS5800iG",boiler,16,pumpkickday,pump kick day,enum [mo\|tu\|we\|th\|fr\|sa\|su\|all] (>=0<=0), ,true,select.boiler_pump_kick_day,select.boiler_pumpkickday,6,0,1,85,1 -"CS5800iG",boiler,16,pumpkickdelay,pump kick delay,uint16 (>=0<=32767),minutes,true,number.boiler_pump_kick_delay,number.boiler_pumpkickdelay,6,0,1,86,1 -"CS5800iG",boiler,16,meterheat,meter heating,uint24,kWh,false,sensor.boiler_meter_heating,sensor.boiler_meterheat,6,0,1/10,100,2 +"CS5800iG",boiler,16,pc0lpm,Flow PC0,uint16,l/min,false,sensor.boiler_Flow_PC0,sensor.boiler_pc0lpm,6,0,1/10,80,1 +"CS5800iG",boiler,16,pc0flow,Flow PC0,uint16,l/h,false,sensor.boiler_Flow_PC0,sensor.boiler_pc0flow,6,0,1,81,1 +"CS5800iG",boiler,16,pc1flow,Flow PC1,uint16,l/h,false,sensor.boiler_Flow_PC1,sensor.boiler_pc1flow,6,0,1,82,1 +"CS5800iG",boiler,16,pc1on,PC1,boolean, ,false,binary_sensor.boiler_PC1,binary_sensor.boiler_pc1on,6,0,1,83,1 +"CS5800iG",boiler,16,pc1rate,PC1 rate,uint8,%,false,sensor.boiler_PC1_rate,sensor.boiler_pc1rate,6,0,1,84,1 +"CS5800iG",boiler,16,pumpkickhour,pump kick hour,uint8 (>=0<=23),hours,true,number.boiler_pump_kick_hour,number.boiler_pumpkickhour,6,0,1,85,1 +"CS5800iG",boiler,16,pumpkickday,pump kick day,enum [mo\|tu\|we\|th\|fr\|sa\|su\|all] (>=0<=0), ,true,select.boiler_pump_kick_day,select.boiler_pumpkickday,6,0,1,86,1 +"CS5800iG",boiler,16,pumpkickdelay,pump kick delay,uint16 (>=0<=32767),minutes,true,number.boiler_pump_kick_delay,number.boiler_pumpkickdelay,6,0,1,87,1 +"CS5800iG",boiler,16,meterheat,meter heating,uint24,kWh,false,sensor.boiler_meter_heating,sensor.boiler_meterheat,6,0,1/10,101,2 "CS5800iG",boiler,16,dhw.meter,meter,uint24,kWh,false,sensor.boiler_dhw_meter,sensor.boiler_dhw_meter,6,9,1/10,2,2 -"CS5800iG",boiler,16,gasmeterheat,gas meter heating,uint24,kWh,false,sensor.boiler_gas_meter_heating,sensor.boiler_gasmeterheat,6,0,1/10,275,2 +"CS5800iG",boiler,16,gasmeterheat,gas meter heating,uint24,kWh,false,sensor.boiler_gas_meter_heating,sensor.boiler_gasmeterheat,6,0,1/10,276,2 "CS5800iG",boiler,16,dhw.gasmeter,gas meter,uint24,kWh,false,sensor.boiler_dhw_gas_meter,sensor.boiler_dhw_gasmeter,6,9,1/10,71,2 -"CS5800iG",boiler,16,nrgheat2,energy heating 2,uint24,kWh,false,sensor.boiler_energy_heating_2,sensor.boiler_nrgheat2,6,0,1/10,277,2 +"CS5800iG",boiler,16,nrgheat2,energy heating 2,uint24,kWh,false,sensor.boiler_energy_heating_2,sensor.boiler_nrgheat2,6,0,1/10,278,2 "CS5800iG",boiler,16,dhw.nrg2,energy 2,uint24,kWh,false,sensor.boiler_dhw_energy_2,sensor.boiler_dhw_nrg2,6,9,1/10,73,2 "CS5800iG",boiler,16,dhw.tapactivated,turn on/off,boolean (>=0<=0), ,true,switch.boiler_dhw_turn_on/off,switch.boiler_dhw_tapactivated,6,9,1,28,1 "CS5800iG",boiler,16,dhw.settemp,set temperature,uint8,C,false,sensor.boiler_dhw_set_temperature,sensor.boiler_dhw_settemp,6,9,1,29,1 @@ -573,9 +577,9 @@ device name,device type,product id,shortname,fullname,type [options...] \| (min/ "CS5800iG",boiler,16,dhw.dhwprio,dhw priority,boolean (>=0<=0), ,true,switch.boiler_dhw_dhw_priority,switch.boiler_dhw_dhwprio,6,9,1,66,1 "CS5800iG",boiler,16,dhw.starts,starts,uint24, ,false,sensor.boiler_dhw_starts,sensor.boiler_dhw_starts,6,9,1,67,2 "CS5800iG",boiler,16,dhw.workm,active time,time,minutes,false,sensor.boiler_dhw_active_time,sensor.boiler_dhw_workm,6,9,1,69,2 -"CS5800iG",boiler,16,nompower,nominal Power,uint8 (>=0<=0),kW,true,number.boiler_nominal_Power,number.boiler_nompower,6,0,1,279,1 -"CS5800iG",boiler,16,nrgtotal,total energy,uint24,kWh,false,sensor.boiler_total_energy,sensor.boiler_nrgtotal,6,0,1/100,88,2 -"CS5800iG",boiler,16,nrgheat,energy heating,uint24 (>=0<=10000000),kWh,true,number.boiler_energy_heating,number.boiler_nrgheat,6,0,1/100,90,2 +"CS5800iG",boiler,16,nompower,nominal Power,uint8 (>=0<=0),kW,true,number.boiler_nominal_Power,number.boiler_nompower,6,0,1,280,1 +"CS5800iG",boiler,16,nrgtotal,total energy,uint24,kWh,false,sensor.boiler_total_energy,sensor.boiler_nrgtotal,6,0,1/100,89,2 +"CS5800iG",boiler,16,nrgheat,energy heating,uint24 (>=0<=10000000),kWh,true,number.boiler_energy_heating,number.boiler_nrgheat,6,0,1/100,91,2 "CS5800iG",boiler,16,dhw.nrg,energy,uint24 (>=0<=10000000),kWh,true,number.boiler_dhw_energy,number.boiler_dhw_nrg,6,9,1/100,0,2 "BK13/BK15, Smartline, GB1*2",boiler,64,reset,reset,cmd [-\|maintenance\|error\|history\|message\|hp error\|burner starts\|factory] (>=0<=0), ,true,sensor.boiler_reset,sensor.boiler_reset,6,0,1,0,1 "BK13/BK15, Smartline, GB1*2",boiler,64,chimneysweeper,chimney sweeper,cmd [off\|on] (>=0<=0), ,true,sensor.boiler_chimney_sweeper,sensor.boiler_chimneysweeper,6,0,1,1,1 @@ -591,28 +595,28 @@ device name,device type,product id,shortname,fullname,type [options...] \| (min/ "BK13/BK15, Smartline, GB1*2",boiler,64,syspress,system pressure,uint8,bar,false,sensor.boiler_system_pressure,sensor.boiler_syspress,6,0,1/10,11,1 "BK13/BK15, Smartline, GB1*2",boiler,64,boiltemp,actual boiler temperature,uint16,C,false,sensor.boiler_actual_boiler_temperature,sensor.boiler_boiltemp,6,0,1/10,12,1 "BK13/BK15, Smartline, GB1*2",boiler,64,headertemp,low loss header,uint16,C,false,sensor.boiler_low_loss_header,sensor.boiler_headertemp,6,0,1/10,13,1 -"BK13/BK15, Smartline, GB1*2",boiler,64,exhausttemp,exhaust temperature,uint16,C,false,sensor.boiler_exhaust_temperature,sensor.boiler_exhausttemp,6,0,1/10,253,1 -"BK13/BK15, Smartline, GB1*2",boiler,64,burngas,gas,boolean, ,false,binary_sensor.boiler_gas,binary_sensor.boiler_burngas,6,0,1,254,1 -"BK13/BK15, Smartline, GB1*2",boiler,64,burngas2,gas stage 2,boolean, ,false,binary_sensor.boiler_gas_stage_2,binary_sensor.boiler_burngas2,6,0,1,255,1 -"BK13/BK15, Smartline, GB1*2",boiler,64,flamecurr,flame current,uint16,µA,false,sensor.boiler_flame_current,sensor.boiler_flamecurr,6,0,1/10,256,1 -"BK13/BK15, Smartline, GB1*2",boiler,64,fanwork,fan,boolean, ,false,binary_sensor.boiler_fan,binary_sensor.boiler_fanwork,6,0,1,257,1 -"BK13/BK15, Smartline, GB1*2",boiler,64,ignwork,ignition,boolean, ,false,binary_sensor.boiler_ignition,binary_sensor.boiler_ignwork,6,0,1,258,1 -"BK13/BK15, Smartline, GB1*2",boiler,64,oilpreheat,oil preheating,boolean, ,false,binary_sensor.boiler_oil_preheating,binary_sensor.boiler_oilpreheat,6,0,1,259,1 -"BK13/BK15, Smartline, GB1*2",boiler,64,burnminpower,burner min power,uint8 (>=0<=0),%,true,number.boiler_burner_min_power,number.boiler_burnminpower,6,0,1,260,1 -"BK13/BK15, Smartline, GB1*2",boiler,64,burnmaxpower,burner max power,uint8 (>=0<=254),%,true,number.boiler_burner_max_power,number.boiler_burnmaxpower,6,0,1,261,1 -"BK13/BK15, Smartline, GB1*2",boiler,64,burnminperiod,burner min period,uint8 (>=0<=120),minutes,true,number.boiler_burner_min_period,number.boiler_burnminperiod,6,0,1,262,1 -"BK13/BK15, Smartline, GB1*2",boiler,64,absburnpow,burner current power (absolute),uint8,%,false,sensor.boiler_burner_current_power_(absolute),sensor.boiler_absburnpow,6,0,1,263,1 -"BK13/BK15, Smartline, GB1*2",boiler,64,heatblock,Heatblock temperature,uint16,C,false,sensor.boiler_Heatblock_temperature,sensor.boiler_heatblock,6,0,1/10,264,1 -"BK13/BK15, Smartline, GB1*2",boiler,64,boilhyston,hysteresis on temperature,int8 (>=-20<=0),C,true,number.boiler_hysteresis_on_temperature,number.boiler_boilhyston,6,0,1,265,1 -"BK13/BK15, Smartline, GB1*2",boiler,64,boilhystoff,hysteresis off temperature,int8 (>=0<=20),C,true,number.boiler_hysteresis_off_temperature,number.boiler_boilhystoff,6,0,1,266,1 -"BK13/BK15, Smartline, GB1*2",boiler,64,boil2hyston,hysteresis stage 2 on temperature,int8 (>=-20<=0),C,true,number.boiler_hysteresis_stage_2_on_temperature,number.boiler_boil2hyston,6,0,1,267,1 -"BK13/BK15, Smartline, GB1*2",boiler,64,boil2hystoff,hysteresis stage 2 off temperature,int8 (>=0<=20),C,true,number.boiler_hysteresis_stage_2_off_temperature,number.boiler_boil2hystoff,6,0,1,268,1 -"BK13/BK15, Smartline, GB1*2",boiler,64,curveon,heatingcurve on,boolean (>=0<=0), ,true,switch.boiler_heatingcurve_on,switch.boiler_curveon,6,0,1,269,1 -"BK13/BK15, Smartline, GB1*2",boiler,64,curvebase,heatingcurve base,uint8 (>=20<=90),C,true,number.boiler_heatingcurve_base,number.boiler_curvebase,6,0,1,270,1 -"BK13/BK15, Smartline, GB1*2",boiler,64,curveend,heatingcurve end,uint8 (>=20<=90),C,true,number.boiler_heatingcurve_end,number.boiler_curveend,6,0,1,271,1 -"BK13/BK15, Smartline, GB1*2",boiler,64,summertemp,summer temperature,uint8 (>=0<=45),C,true,number.boiler_summer_temperature,number.boiler_summertemp,6,0,1,272,1 -"BK13/BK15, Smartline, GB1*2",boiler,64,nofrostmode,nofrost mode,boolean (>=0<=0), ,true,switch.boiler_nofrost_mode,switch.boiler_nofrostmode,6,0,1,273,1 -"BK13/BK15, Smartline, GB1*2",boiler,64,nofrosttemp,nofrost temperature,uint8 (>=0<=10),C,true,number.boiler_nofrost_temperature,number.boiler_nofrosttemp,6,0,1,274,1 +"BK13/BK15, Smartline, GB1*2",boiler,64,exhausttemp,exhaust temperature,uint16,C,false,sensor.boiler_exhaust_temperature,sensor.boiler_exhausttemp,6,0,1/10,254,1 +"BK13/BK15, Smartline, GB1*2",boiler,64,burngas,gas,boolean, ,false,binary_sensor.boiler_gas,binary_sensor.boiler_burngas,6,0,1,255,1 +"BK13/BK15, Smartline, GB1*2",boiler,64,burngas2,gas stage 2,boolean, ,false,binary_sensor.boiler_gas_stage_2,binary_sensor.boiler_burngas2,6,0,1,256,1 +"BK13/BK15, Smartline, GB1*2",boiler,64,flamecurr,flame current,uint16,µA,false,sensor.boiler_flame_current,sensor.boiler_flamecurr,6,0,1/10,257,1 +"BK13/BK15, Smartline, GB1*2",boiler,64,fanwork,fan,boolean, ,false,binary_sensor.boiler_fan,binary_sensor.boiler_fanwork,6,0,1,258,1 +"BK13/BK15, Smartline, GB1*2",boiler,64,ignwork,ignition,boolean, ,false,binary_sensor.boiler_ignition,binary_sensor.boiler_ignwork,6,0,1,259,1 +"BK13/BK15, Smartline, GB1*2",boiler,64,oilpreheat,oil preheating,boolean, ,false,binary_sensor.boiler_oil_preheating,binary_sensor.boiler_oilpreheat,6,0,1,260,1 +"BK13/BK15, Smartline, GB1*2",boiler,64,burnminpower,burner min power,uint8 (>=0<=0),%,true,number.boiler_burner_min_power,number.boiler_burnminpower,6,0,1,261,1 +"BK13/BK15, Smartline, GB1*2",boiler,64,burnmaxpower,burner max power,uint8 (>=0<=254),%,true,number.boiler_burner_max_power,number.boiler_burnmaxpower,6,0,1,262,1 +"BK13/BK15, Smartline, GB1*2",boiler,64,burnminperiod,burner min period,uint8 (>=0<=120),minutes,true,number.boiler_burner_min_period,number.boiler_burnminperiod,6,0,1,263,1 +"BK13/BK15, Smartline, GB1*2",boiler,64,absburnpow,burner current power (absolute),uint8,%,false,sensor.boiler_burner_current_power_(absolute),sensor.boiler_absburnpow,6,0,1,264,1 +"BK13/BK15, Smartline, GB1*2",boiler,64,heatblock,Heatblock temperature,uint16,C,false,sensor.boiler_Heatblock_temperature,sensor.boiler_heatblock,6,0,1/10,265,1 +"BK13/BK15, Smartline, GB1*2",boiler,64,boilhyston,hysteresis on temperature,int8 (>=-20<=0),C,true,number.boiler_hysteresis_on_temperature,number.boiler_boilhyston,6,0,1,266,1 +"BK13/BK15, Smartline, GB1*2",boiler,64,boilhystoff,hysteresis off temperature,int8 (>=0<=20),C,true,number.boiler_hysteresis_off_temperature,number.boiler_boilhystoff,6,0,1,267,1 +"BK13/BK15, Smartline, GB1*2",boiler,64,boil2hyston,hysteresis stage 2 on temperature,int8 (>=-20<=0),C,true,number.boiler_hysteresis_stage_2_on_temperature,number.boiler_boil2hyston,6,0,1,268,1 +"BK13/BK15, Smartline, GB1*2",boiler,64,boil2hystoff,hysteresis stage 2 off temperature,int8 (>=0<=20),C,true,number.boiler_hysteresis_stage_2_off_temperature,number.boiler_boil2hystoff,6,0,1,269,1 +"BK13/BK15, Smartline, GB1*2",boiler,64,curveon,heatingcurve on,boolean (>=0<=0), ,true,switch.boiler_heatingcurve_on,switch.boiler_curveon,6,0,1,270,1 +"BK13/BK15, Smartline, GB1*2",boiler,64,curvebase,heatingcurve base,uint8 (>=20<=90),C,true,number.boiler_heatingcurve_base,number.boiler_curvebase,6,0,1,271,1 +"BK13/BK15, Smartline, GB1*2",boiler,64,curveend,heatingcurve end,uint8 (>=20<=90),C,true,number.boiler_heatingcurve_end,number.boiler_curveend,6,0,1,272,1 +"BK13/BK15, Smartline, GB1*2",boiler,64,summertemp,summer temperature,uint8 (>=0<=45),C,true,number.boiler_summer_temperature,number.boiler_summertemp,6,0,1,273,1 +"BK13/BK15, Smartline, GB1*2",boiler,64,nofrostmode,nofrost mode,boolean (>=0<=0), ,true,switch.boiler_nofrost_mode,switch.boiler_nofrostmode,6,0,1,274,1 +"BK13/BK15, Smartline, GB1*2",boiler,64,nofrosttemp,nofrost temperature,uint8 (>=0<=10),C,true,number.boiler_nofrost_temperature,number.boiler_nofrosttemp,6,0,1,275,1 "BK13/BK15, Smartline, GB1*2",boiler,64,heatingactivated,heating activated,boolean (>=0<=0), ,true,switch.boiler_heating_activated,switch.boiler_heatingactivated,6,0,1,14,1 "BK13/BK15, Smartline, GB1*2",boiler,64,heatingtemp,heating temperature,uint8 (>=0<=90),C,true,number.boiler_heating_temperature,number.boiler_heatingtemp,6,0,1,15,1 "BK13/BK15, Smartline, GB1*2",boiler,64,heatingpump,heating pump,boolean, ,false,binary_sensor.boiler_heating_pump,binary_sensor.boiler_heatingpump,6,0,1,16,1 @@ -639,18 +643,19 @@ device name,device type,product id,shortname,fullname,type [options...] \| (min/ "BK13/BK15, Smartline, GB1*2",boiler,64,maintenancedate,next maintenance date,string (>=0<=0), ,true,sensor.boiler_next_maintenance_date,sensor.boiler_maintenancedate,6,0,1,72,6 "BK13/BK15, Smartline, GB1*2",boiler,64,emergencyops,emergency operation,boolean (>=0<=0), ,true,switch.boiler_emergency_operation,switch.boiler_emergencyops,6,0,1,78,1 "BK13/BK15, Smartline, GB1*2",boiler,64,emergencytemp,emergency temperature,uint8 (>=15<=70),C,true,number.boiler_emergency_temperature,number.boiler_emergencytemp,6,0,1,79,1 -"BK13/BK15, Smartline, GB1*2",boiler,64,pc0flow,Flow PC0,int16,l/h,false,sensor.boiler_Flow_PC0,sensor.boiler_pc0flow,6,0,1,80,1 -"BK13/BK15, Smartline, GB1*2",boiler,64,pc1flow,Flow PC1,int16,l/h,false,sensor.boiler_Flow_PC1,sensor.boiler_pc1flow,6,0,1,81,1 -"BK13/BK15, Smartline, GB1*2",boiler,64,pc1on,PC1,boolean, ,false,binary_sensor.boiler_PC1,binary_sensor.boiler_pc1on,6,0,1,82,1 -"BK13/BK15, Smartline, GB1*2",boiler,64,pc1rate,PC1 rate,uint8,%,false,sensor.boiler_PC1_rate,sensor.boiler_pc1rate,6,0,1,83,1 -"BK13/BK15, Smartline, GB1*2",boiler,64,pumpkickhour,pump kick hour,uint8 (>=0<=23),hours,true,number.boiler_pump_kick_hour,number.boiler_pumpkickhour,6,0,1,84,1 -"BK13/BK15, Smartline, GB1*2",boiler,64,pumpkickday,pump kick day,enum [mo\|tu\|we\|th\|fr\|sa\|su\|all] (>=0<=0), ,true,select.boiler_pump_kick_day,select.boiler_pumpkickday,6,0,1,85,1 -"BK13/BK15, Smartline, GB1*2",boiler,64,pumpkickdelay,pump kick delay,uint16 (>=0<=32767),minutes,true,number.boiler_pump_kick_delay,number.boiler_pumpkickdelay,6,0,1,86,1 -"BK13/BK15, Smartline, GB1*2",boiler,64,meterheat,meter heating,uint24,kWh,false,sensor.boiler_meter_heating,sensor.boiler_meterheat,6,0,1/10,100,2 +"BK13/BK15, Smartline, GB1*2",boiler,64,pc0lpm,Flow PC0,uint16,l/min,false,sensor.boiler_Flow_PC0,sensor.boiler_pc0lpm,6,0,1/10,80,1 +"BK13/BK15, Smartline, GB1*2",boiler,64,pc0flow,Flow PC0,uint16,l/h,false,sensor.boiler_Flow_PC0,sensor.boiler_pc0flow,6,0,1,81,1 +"BK13/BK15, Smartline, GB1*2",boiler,64,pc1flow,Flow PC1,uint16,l/h,false,sensor.boiler_Flow_PC1,sensor.boiler_pc1flow,6,0,1,82,1 +"BK13/BK15, Smartline, GB1*2",boiler,64,pc1on,PC1,boolean, ,false,binary_sensor.boiler_PC1,binary_sensor.boiler_pc1on,6,0,1,83,1 +"BK13/BK15, Smartline, GB1*2",boiler,64,pc1rate,PC1 rate,uint8,%,false,sensor.boiler_PC1_rate,sensor.boiler_pc1rate,6,0,1,84,1 +"BK13/BK15, Smartline, GB1*2",boiler,64,pumpkickhour,pump kick hour,uint8 (>=0<=23),hours,true,number.boiler_pump_kick_hour,number.boiler_pumpkickhour,6,0,1,85,1 +"BK13/BK15, Smartline, GB1*2",boiler,64,pumpkickday,pump kick day,enum [mo\|tu\|we\|th\|fr\|sa\|su\|all] (>=0<=0), ,true,select.boiler_pump_kick_day,select.boiler_pumpkickday,6,0,1,86,1 +"BK13/BK15, Smartline, GB1*2",boiler,64,pumpkickdelay,pump kick delay,uint16 (>=0<=32767),minutes,true,number.boiler_pump_kick_delay,number.boiler_pumpkickdelay,6,0,1,87,1 +"BK13/BK15, Smartline, GB1*2",boiler,64,meterheat,meter heating,uint24,kWh,false,sensor.boiler_meter_heating,sensor.boiler_meterheat,6,0,1/10,101,2 "BK13/BK15, Smartline, GB1*2",boiler,64,dhw.meter,meter,uint24,kWh,false,sensor.boiler_dhw_meter,sensor.boiler_dhw_meter,6,9,1/10,2,2 -"BK13/BK15, Smartline, GB1*2",boiler,64,gasmeterheat,gas meter heating,uint24,kWh,false,sensor.boiler_gas_meter_heating,sensor.boiler_gasmeterheat,6,0,1/10,275,2 +"BK13/BK15, Smartline, GB1*2",boiler,64,gasmeterheat,gas meter heating,uint24,kWh,false,sensor.boiler_gas_meter_heating,sensor.boiler_gasmeterheat,6,0,1/10,276,2 "BK13/BK15, Smartline, GB1*2",boiler,64,dhw.gasmeter,gas meter,uint24,kWh,false,sensor.boiler_dhw_gas_meter,sensor.boiler_dhw_gasmeter,6,9,1/10,71,2 -"BK13/BK15, Smartline, GB1*2",boiler,64,nrgheat2,energy heating 2,uint24,kWh,false,sensor.boiler_energy_heating_2,sensor.boiler_nrgheat2,6,0,1/10,277,2 +"BK13/BK15, Smartline, GB1*2",boiler,64,nrgheat2,energy heating 2,uint24,kWh,false,sensor.boiler_energy_heating_2,sensor.boiler_nrgheat2,6,0,1/10,278,2 "BK13/BK15, Smartline, GB1*2",boiler,64,dhw.nrg2,energy 2,uint24,kWh,false,sensor.boiler_dhw_energy_2,sensor.boiler_dhw_nrg2,6,9,1/10,73,2 "BK13/BK15, Smartline, GB1*2",boiler,64,dhw.tapactivated,turn on/off,boolean (>=0<=0), ,true,switch.boiler_dhw_turn_on/off,switch.boiler_dhw_tapactivated,6,9,1,28,1 "BK13/BK15, Smartline, GB1*2",boiler,64,dhw.settemp,set temperature,uint8,C,false,sensor.boiler_dhw_set_temperature,sensor.boiler_dhw_settemp,6,9,1,29,1 @@ -693,9 +698,9 @@ device name,device type,product id,shortname,fullname,type [options...] \| (min/ "BK13/BK15, Smartline, GB1*2",boiler,64,dhw.dhwprio,dhw priority,boolean (>=0<=0), ,true,switch.boiler_dhw_dhw_priority,switch.boiler_dhw_dhwprio,6,9,1,66,1 "BK13/BK15, Smartline, GB1*2",boiler,64,dhw.starts,starts,uint24, ,false,sensor.boiler_dhw_starts,sensor.boiler_dhw_starts,6,9,1,67,2 "BK13/BK15, Smartline, GB1*2",boiler,64,dhw.workm,active time,time,minutes,false,sensor.boiler_dhw_active_time,sensor.boiler_dhw_workm,6,9,1,69,2 -"BK13/BK15, Smartline, GB1*2",boiler,64,nompower,nominal Power,uint8 (>=0<=0),kW,true,number.boiler_nominal_Power,number.boiler_nompower,6,0,1,279,1 -"BK13/BK15, Smartline, GB1*2",boiler,64,nrgtotal,total energy,uint24,kWh,false,sensor.boiler_total_energy,sensor.boiler_nrgtotal,6,0,1/100,88,2 -"BK13/BK15, Smartline, GB1*2",boiler,64,nrgheat,energy heating,uint24 (>=0<=10000000),kWh,true,number.boiler_energy_heating,number.boiler_nrgheat,6,0,1/100,90,2 +"BK13/BK15, Smartline, GB1*2",boiler,64,nompower,nominal Power,uint8 (>=0<=0),kW,true,number.boiler_nominal_Power,number.boiler_nompower,6,0,1,280,1 +"BK13/BK15, Smartline, GB1*2",boiler,64,nrgtotal,total energy,uint24,kWh,false,sensor.boiler_total_energy,sensor.boiler_nrgtotal,6,0,1/100,89,2 +"BK13/BK15, Smartline, GB1*2",boiler,64,nrgheat,energy heating,uint24 (>=0<=10000000),kWh,true,number.boiler_energy_heating,number.boiler_nrgheat,6,0,1/100,91,2 "BK13/BK15, Smartline, GB1*2",boiler,64,dhw.nrg,energy,uint24 (>=0<=10000000),kWh,true,number.boiler_dhw_energy,number.boiler_dhw_nrg,6,9,1/100,0,2 "Logano GB1*5, Logamatic MC10",boiler,72,reset,reset,cmd [-\|maintenance\|error\|history\|message\|hp error\|burner starts\|factory] (>=0<=0), ,true,sensor.boiler_reset,sensor.boiler_reset,6,0,1,0,1 "Logano GB1*5, Logamatic MC10",boiler,72,chimneysweeper,chimney sweeper,cmd [off\|on] (>=0<=0), ,true,sensor.boiler_chimney_sweeper,sensor.boiler_chimneysweeper,6,0,1,1,1 @@ -711,28 +716,28 @@ device name,device type,product id,shortname,fullname,type [options...] \| (min/ "Logano GB1*5, Logamatic MC10",boiler,72,syspress,system pressure,uint8,bar,false,sensor.boiler_system_pressure,sensor.boiler_syspress,6,0,1/10,11,1 "Logano GB1*5, Logamatic MC10",boiler,72,boiltemp,actual boiler temperature,uint16,C,false,sensor.boiler_actual_boiler_temperature,sensor.boiler_boiltemp,6,0,1/10,12,1 "Logano GB1*5, Logamatic MC10",boiler,72,headertemp,low loss header,uint16,C,false,sensor.boiler_low_loss_header,sensor.boiler_headertemp,6,0,1/10,13,1 -"Logano GB1*5, Logamatic MC10",boiler,72,exhausttemp,exhaust temperature,uint16,C,false,sensor.boiler_exhaust_temperature,sensor.boiler_exhausttemp,6,0,1/10,253,1 -"Logano GB1*5, Logamatic MC10",boiler,72,burngas,gas,boolean, ,false,binary_sensor.boiler_gas,binary_sensor.boiler_burngas,6,0,1,254,1 -"Logano GB1*5, Logamatic MC10",boiler,72,burngas2,gas stage 2,boolean, ,false,binary_sensor.boiler_gas_stage_2,binary_sensor.boiler_burngas2,6,0,1,255,1 -"Logano GB1*5, Logamatic MC10",boiler,72,flamecurr,flame current,uint16,µA,false,sensor.boiler_flame_current,sensor.boiler_flamecurr,6,0,1/10,256,1 -"Logano GB1*5, Logamatic MC10",boiler,72,fanwork,fan,boolean, ,false,binary_sensor.boiler_fan,binary_sensor.boiler_fanwork,6,0,1,257,1 -"Logano GB1*5, Logamatic MC10",boiler,72,ignwork,ignition,boolean, ,false,binary_sensor.boiler_ignition,binary_sensor.boiler_ignwork,6,0,1,258,1 -"Logano GB1*5, Logamatic MC10",boiler,72,oilpreheat,oil preheating,boolean, ,false,binary_sensor.boiler_oil_preheating,binary_sensor.boiler_oilpreheat,6,0,1,259,1 -"Logano GB1*5, Logamatic MC10",boiler,72,burnminpower,burner min power,uint8 (>=0<=0),%,true,number.boiler_burner_min_power,number.boiler_burnminpower,6,0,1,260,1 -"Logano GB1*5, Logamatic MC10",boiler,72,burnmaxpower,burner max power,uint8 (>=0<=254),%,true,number.boiler_burner_max_power,number.boiler_burnmaxpower,6,0,1,261,1 -"Logano GB1*5, Logamatic MC10",boiler,72,burnminperiod,burner min period,uint8 (>=0<=120),minutes,true,number.boiler_burner_min_period,number.boiler_burnminperiod,6,0,1,262,1 -"Logano GB1*5, Logamatic MC10",boiler,72,absburnpow,burner current power (absolute),uint8,%,false,sensor.boiler_burner_current_power_(absolute),sensor.boiler_absburnpow,6,0,1,263,1 -"Logano GB1*5, Logamatic MC10",boiler,72,heatblock,Heatblock temperature,uint16,C,false,sensor.boiler_Heatblock_temperature,sensor.boiler_heatblock,6,0,1/10,264,1 -"Logano GB1*5, Logamatic MC10",boiler,72,boilhyston,hysteresis on temperature,int8 (>=-20<=0),C,true,number.boiler_hysteresis_on_temperature,number.boiler_boilhyston,6,0,1,265,1 -"Logano GB1*5, Logamatic MC10",boiler,72,boilhystoff,hysteresis off temperature,int8 (>=0<=20),C,true,number.boiler_hysteresis_off_temperature,number.boiler_boilhystoff,6,0,1,266,1 -"Logano GB1*5, Logamatic MC10",boiler,72,boil2hyston,hysteresis stage 2 on temperature,int8 (>=-20<=0),C,true,number.boiler_hysteresis_stage_2_on_temperature,number.boiler_boil2hyston,6,0,1,267,1 -"Logano GB1*5, Logamatic MC10",boiler,72,boil2hystoff,hysteresis stage 2 off temperature,int8 (>=0<=20),C,true,number.boiler_hysteresis_stage_2_off_temperature,number.boiler_boil2hystoff,6,0,1,268,1 -"Logano GB1*5, Logamatic MC10",boiler,72,curveon,heatingcurve on,boolean (>=0<=0), ,true,switch.boiler_heatingcurve_on,switch.boiler_curveon,6,0,1,269,1 -"Logano GB1*5, Logamatic MC10",boiler,72,curvebase,heatingcurve base,uint8 (>=20<=90),C,true,number.boiler_heatingcurve_base,number.boiler_curvebase,6,0,1,270,1 -"Logano GB1*5, Logamatic MC10",boiler,72,curveend,heatingcurve end,uint8 (>=20<=90),C,true,number.boiler_heatingcurve_end,number.boiler_curveend,6,0,1,271,1 -"Logano GB1*5, Logamatic MC10",boiler,72,summertemp,summer temperature,uint8 (>=0<=45),C,true,number.boiler_summer_temperature,number.boiler_summertemp,6,0,1,272,1 -"Logano GB1*5, Logamatic MC10",boiler,72,nofrostmode,nofrost mode,boolean (>=0<=0), ,true,switch.boiler_nofrost_mode,switch.boiler_nofrostmode,6,0,1,273,1 -"Logano GB1*5, Logamatic MC10",boiler,72,nofrosttemp,nofrost temperature,uint8 (>=0<=10),C,true,number.boiler_nofrost_temperature,number.boiler_nofrosttemp,6,0,1,274,1 +"Logano GB1*5, Logamatic MC10",boiler,72,exhausttemp,exhaust temperature,uint16,C,false,sensor.boiler_exhaust_temperature,sensor.boiler_exhausttemp,6,0,1/10,254,1 +"Logano GB1*5, Logamatic MC10",boiler,72,burngas,gas,boolean, ,false,binary_sensor.boiler_gas,binary_sensor.boiler_burngas,6,0,1,255,1 +"Logano GB1*5, Logamatic MC10",boiler,72,burngas2,gas stage 2,boolean, ,false,binary_sensor.boiler_gas_stage_2,binary_sensor.boiler_burngas2,6,0,1,256,1 +"Logano GB1*5, Logamatic MC10",boiler,72,flamecurr,flame current,uint16,µA,false,sensor.boiler_flame_current,sensor.boiler_flamecurr,6,0,1/10,257,1 +"Logano GB1*5, Logamatic MC10",boiler,72,fanwork,fan,boolean, ,false,binary_sensor.boiler_fan,binary_sensor.boiler_fanwork,6,0,1,258,1 +"Logano GB1*5, Logamatic MC10",boiler,72,ignwork,ignition,boolean, ,false,binary_sensor.boiler_ignition,binary_sensor.boiler_ignwork,6,0,1,259,1 +"Logano GB1*5, Logamatic MC10",boiler,72,oilpreheat,oil preheating,boolean, ,false,binary_sensor.boiler_oil_preheating,binary_sensor.boiler_oilpreheat,6,0,1,260,1 +"Logano GB1*5, Logamatic MC10",boiler,72,burnminpower,burner min power,uint8 (>=0<=0),%,true,number.boiler_burner_min_power,number.boiler_burnminpower,6,0,1,261,1 +"Logano GB1*5, Logamatic MC10",boiler,72,burnmaxpower,burner max power,uint8 (>=0<=254),%,true,number.boiler_burner_max_power,number.boiler_burnmaxpower,6,0,1,262,1 +"Logano GB1*5, Logamatic MC10",boiler,72,burnminperiod,burner min period,uint8 (>=0<=120),minutes,true,number.boiler_burner_min_period,number.boiler_burnminperiod,6,0,1,263,1 +"Logano GB1*5, Logamatic MC10",boiler,72,absburnpow,burner current power (absolute),uint8,%,false,sensor.boiler_burner_current_power_(absolute),sensor.boiler_absburnpow,6,0,1,264,1 +"Logano GB1*5, Logamatic MC10",boiler,72,heatblock,Heatblock temperature,uint16,C,false,sensor.boiler_Heatblock_temperature,sensor.boiler_heatblock,6,0,1/10,265,1 +"Logano GB1*5, Logamatic MC10",boiler,72,boilhyston,hysteresis on temperature,int8 (>=-20<=0),C,true,number.boiler_hysteresis_on_temperature,number.boiler_boilhyston,6,0,1,266,1 +"Logano GB1*5, Logamatic MC10",boiler,72,boilhystoff,hysteresis off temperature,int8 (>=0<=20),C,true,number.boiler_hysteresis_off_temperature,number.boiler_boilhystoff,6,0,1,267,1 +"Logano GB1*5, Logamatic MC10",boiler,72,boil2hyston,hysteresis stage 2 on temperature,int8 (>=-20<=0),C,true,number.boiler_hysteresis_stage_2_on_temperature,number.boiler_boil2hyston,6,0,1,268,1 +"Logano GB1*5, Logamatic MC10",boiler,72,boil2hystoff,hysteresis stage 2 off temperature,int8 (>=0<=20),C,true,number.boiler_hysteresis_stage_2_off_temperature,number.boiler_boil2hystoff,6,0,1,269,1 +"Logano GB1*5, Logamatic MC10",boiler,72,curveon,heatingcurve on,boolean (>=0<=0), ,true,switch.boiler_heatingcurve_on,switch.boiler_curveon,6,0,1,270,1 +"Logano GB1*5, Logamatic MC10",boiler,72,curvebase,heatingcurve base,uint8 (>=20<=90),C,true,number.boiler_heatingcurve_base,number.boiler_curvebase,6,0,1,271,1 +"Logano GB1*5, Logamatic MC10",boiler,72,curveend,heatingcurve end,uint8 (>=20<=90),C,true,number.boiler_heatingcurve_end,number.boiler_curveend,6,0,1,272,1 +"Logano GB1*5, Logamatic MC10",boiler,72,summertemp,summer temperature,uint8 (>=0<=45),C,true,number.boiler_summer_temperature,number.boiler_summertemp,6,0,1,273,1 +"Logano GB1*5, Logamatic MC10",boiler,72,nofrostmode,nofrost mode,boolean (>=0<=0), ,true,switch.boiler_nofrost_mode,switch.boiler_nofrostmode,6,0,1,274,1 +"Logano GB1*5, Logamatic MC10",boiler,72,nofrosttemp,nofrost temperature,uint8 (>=0<=10),C,true,number.boiler_nofrost_temperature,number.boiler_nofrosttemp,6,0,1,275,1 "Logano GB1*5, Logamatic MC10",boiler,72,heatingactivated,heating activated,boolean (>=0<=0), ,true,switch.boiler_heating_activated,switch.boiler_heatingactivated,6,0,1,14,1 "Logano GB1*5, Logamatic MC10",boiler,72,heatingtemp,heating temperature,uint8 (>=0<=90),C,true,number.boiler_heating_temperature,number.boiler_heatingtemp,6,0,1,15,1 "Logano GB1*5, Logamatic MC10",boiler,72,heatingpump,heating pump,boolean, ,false,binary_sensor.boiler_heating_pump,binary_sensor.boiler_heatingpump,6,0,1,16,1 @@ -759,18 +764,19 @@ device name,device type,product id,shortname,fullname,type [options...] \| (min/ "Logano GB1*5, Logamatic MC10",boiler,72,maintenancedate,next maintenance date,string (>=0<=0), ,true,sensor.boiler_next_maintenance_date,sensor.boiler_maintenancedate,6,0,1,72,6 "Logano GB1*5, Logamatic MC10",boiler,72,emergencyops,emergency operation,boolean (>=0<=0), ,true,switch.boiler_emergency_operation,switch.boiler_emergencyops,6,0,1,78,1 "Logano GB1*5, Logamatic MC10",boiler,72,emergencytemp,emergency temperature,uint8 (>=15<=70),C,true,number.boiler_emergency_temperature,number.boiler_emergencytemp,6,0,1,79,1 -"Logano GB1*5, Logamatic MC10",boiler,72,pc0flow,Flow PC0,int16,l/h,false,sensor.boiler_Flow_PC0,sensor.boiler_pc0flow,6,0,1,80,1 -"Logano GB1*5, Logamatic MC10",boiler,72,pc1flow,Flow PC1,int16,l/h,false,sensor.boiler_Flow_PC1,sensor.boiler_pc1flow,6,0,1,81,1 -"Logano GB1*5, Logamatic MC10",boiler,72,pc1on,PC1,boolean, ,false,binary_sensor.boiler_PC1,binary_sensor.boiler_pc1on,6,0,1,82,1 -"Logano GB1*5, Logamatic MC10",boiler,72,pc1rate,PC1 rate,uint8,%,false,sensor.boiler_PC1_rate,sensor.boiler_pc1rate,6,0,1,83,1 -"Logano GB1*5, Logamatic MC10",boiler,72,pumpkickhour,pump kick hour,uint8 (>=0<=23),hours,true,number.boiler_pump_kick_hour,number.boiler_pumpkickhour,6,0,1,84,1 -"Logano GB1*5, Logamatic MC10",boiler,72,pumpkickday,pump kick day,enum [mo\|tu\|we\|th\|fr\|sa\|su\|all] (>=0<=0), ,true,select.boiler_pump_kick_day,select.boiler_pumpkickday,6,0,1,85,1 -"Logano GB1*5, Logamatic MC10",boiler,72,pumpkickdelay,pump kick delay,uint16 (>=0<=32767),minutes,true,number.boiler_pump_kick_delay,number.boiler_pumpkickdelay,6,0,1,86,1 -"Logano GB1*5, Logamatic MC10",boiler,72,meterheat,meter heating,uint24,kWh,false,sensor.boiler_meter_heating,sensor.boiler_meterheat,6,0,1/10,100,2 +"Logano GB1*5, Logamatic MC10",boiler,72,pc0lpm,Flow PC0,uint16,l/min,false,sensor.boiler_Flow_PC0,sensor.boiler_pc0lpm,6,0,1/10,80,1 +"Logano GB1*5, Logamatic MC10",boiler,72,pc0flow,Flow PC0,uint16,l/h,false,sensor.boiler_Flow_PC0,sensor.boiler_pc0flow,6,0,1,81,1 +"Logano GB1*5, Logamatic MC10",boiler,72,pc1flow,Flow PC1,uint16,l/h,false,sensor.boiler_Flow_PC1,sensor.boiler_pc1flow,6,0,1,82,1 +"Logano GB1*5, Logamatic MC10",boiler,72,pc1on,PC1,boolean, ,false,binary_sensor.boiler_PC1,binary_sensor.boiler_pc1on,6,0,1,83,1 +"Logano GB1*5, Logamatic MC10",boiler,72,pc1rate,PC1 rate,uint8,%,false,sensor.boiler_PC1_rate,sensor.boiler_pc1rate,6,0,1,84,1 +"Logano GB1*5, Logamatic MC10",boiler,72,pumpkickhour,pump kick hour,uint8 (>=0<=23),hours,true,number.boiler_pump_kick_hour,number.boiler_pumpkickhour,6,0,1,85,1 +"Logano GB1*5, Logamatic MC10",boiler,72,pumpkickday,pump kick day,enum [mo\|tu\|we\|th\|fr\|sa\|su\|all] (>=0<=0), ,true,select.boiler_pump_kick_day,select.boiler_pumpkickday,6,0,1,86,1 +"Logano GB1*5, Logamatic MC10",boiler,72,pumpkickdelay,pump kick delay,uint16 (>=0<=32767),minutes,true,number.boiler_pump_kick_delay,number.boiler_pumpkickdelay,6,0,1,87,1 +"Logano GB1*5, Logamatic MC10",boiler,72,meterheat,meter heating,uint24,kWh,false,sensor.boiler_meter_heating,sensor.boiler_meterheat,6,0,1/10,101,2 "Logano GB1*5, Logamatic MC10",boiler,72,dhw.meter,meter,uint24,kWh,false,sensor.boiler_dhw_meter,sensor.boiler_dhw_meter,6,9,1/10,2,2 -"Logano GB1*5, Logamatic MC10",boiler,72,gasmeterheat,gas meter heating,uint24,kWh,false,sensor.boiler_gas_meter_heating,sensor.boiler_gasmeterheat,6,0,1/10,275,2 +"Logano GB1*5, Logamatic MC10",boiler,72,gasmeterheat,gas meter heating,uint24,kWh,false,sensor.boiler_gas_meter_heating,sensor.boiler_gasmeterheat,6,0,1/10,276,2 "Logano GB1*5, Logamatic MC10",boiler,72,dhw.gasmeter,gas meter,uint24,kWh,false,sensor.boiler_dhw_gas_meter,sensor.boiler_dhw_gasmeter,6,9,1/10,71,2 -"Logano GB1*5, Logamatic MC10",boiler,72,nrgheat2,energy heating 2,uint24,kWh,false,sensor.boiler_energy_heating_2,sensor.boiler_nrgheat2,6,0,1/10,277,2 +"Logano GB1*5, Logamatic MC10",boiler,72,nrgheat2,energy heating 2,uint24,kWh,false,sensor.boiler_energy_heating_2,sensor.boiler_nrgheat2,6,0,1/10,278,2 "Logano GB1*5, Logamatic MC10",boiler,72,dhw.nrg2,energy 2,uint24,kWh,false,sensor.boiler_dhw_energy_2,sensor.boiler_dhw_nrg2,6,9,1/10,73,2 "Logano GB1*5, Logamatic MC10",boiler,72,dhw.tapactivated,turn on/off,boolean (>=0<=0), ,true,switch.boiler_dhw_turn_on/off,switch.boiler_dhw_tapactivated,6,9,1,28,1 "Logano GB1*5, Logamatic MC10",boiler,72,dhw.settemp,set temperature,uint8,C,false,sensor.boiler_dhw_set_temperature,sensor.boiler_dhw_settemp,6,9,1,29,1 @@ -813,9 +819,9 @@ device name,device type,product id,shortname,fullname,type [options...] \| (min/ "Logano GB1*5, Logamatic MC10",boiler,72,dhw.dhwprio,dhw priority,boolean (>=0<=0), ,true,switch.boiler_dhw_dhw_priority,switch.boiler_dhw_dhwprio,6,9,1,66,1 "Logano GB1*5, Logamatic MC10",boiler,72,dhw.starts,starts,uint24, ,false,sensor.boiler_dhw_starts,sensor.boiler_dhw_starts,6,9,1,67,2 "Logano GB1*5, Logamatic MC10",boiler,72,dhw.workm,active time,time,minutes,false,sensor.boiler_dhw_active_time,sensor.boiler_dhw_workm,6,9,1,69,2 -"Logano GB1*5, Logamatic MC10",boiler,72,nompower,nominal Power,uint8 (>=0<=0),kW,true,number.boiler_nominal_Power,number.boiler_nompower,6,0,1,279,1 -"Logano GB1*5, Logamatic MC10",boiler,72,nrgtotal,total energy,uint24,kWh,false,sensor.boiler_total_energy,sensor.boiler_nrgtotal,6,0,1/100,88,2 -"Logano GB1*5, Logamatic MC10",boiler,72,nrgheat,energy heating,uint24 (>=0<=10000000),kWh,true,number.boiler_energy_heating,number.boiler_nrgheat,6,0,1/100,90,2 +"Logano GB1*5, Logamatic MC10",boiler,72,nompower,nominal Power,uint8 (>=0<=0),kW,true,number.boiler_nominal_Power,number.boiler_nompower,6,0,1,280,1 +"Logano GB1*5, Logamatic MC10",boiler,72,nrgtotal,total energy,uint24,kWh,false,sensor.boiler_total_energy,sensor.boiler_nrgtotal,6,0,1/100,89,2 +"Logano GB1*5, Logamatic MC10",boiler,72,nrgheat,energy heating,uint24 (>=0<=10000000),kWh,true,number.boiler_energy_heating,number.boiler_nrgheat,6,0,1/100,91,2 "Logano GB1*5, Logamatic MC10",boiler,72,dhw.nrg,energy,uint24 (>=0<=10000000),kWh,true,number.boiler_dhw_energy,number.boiler_dhw_nrg,6,9,1/100,0,2 "Cascade CM10",boiler,81,reset,reset,cmd [-\|maintenance\|error\|history\|message\|hp error\|burner starts\|factory] (>=0<=0), ,true,sensor.boiler_reset,sensor.boiler_reset,6,0,1,0,1 "Cascade CM10",boiler,81,chimneysweeper,chimney sweeper,cmd [off\|on] (>=0<=0), ,true,sensor.boiler_chimney_sweeper,sensor.boiler_chimneysweeper,6,0,1,1,1 @@ -831,28 +837,28 @@ device name,device type,product id,shortname,fullname,type [options...] \| (min/ "Cascade CM10",boiler,81,syspress,system pressure,uint8,bar,false,sensor.boiler_system_pressure,sensor.boiler_syspress,6,0,1/10,11,1 "Cascade CM10",boiler,81,boiltemp,actual boiler temperature,uint16,C,false,sensor.boiler_actual_boiler_temperature,sensor.boiler_boiltemp,6,0,1/10,12,1 "Cascade CM10",boiler,81,headertemp,low loss header,uint16,C,false,sensor.boiler_low_loss_header,sensor.boiler_headertemp,6,0,1/10,13,1 -"Cascade CM10",boiler,81,exhausttemp,exhaust temperature,uint16,C,false,sensor.boiler_exhaust_temperature,sensor.boiler_exhausttemp,6,0,1/10,253,1 -"Cascade CM10",boiler,81,burngas,gas,boolean, ,false,binary_sensor.boiler_gas,binary_sensor.boiler_burngas,6,0,1,254,1 -"Cascade CM10",boiler,81,burngas2,gas stage 2,boolean, ,false,binary_sensor.boiler_gas_stage_2,binary_sensor.boiler_burngas2,6,0,1,255,1 -"Cascade CM10",boiler,81,flamecurr,flame current,uint16,µA,false,sensor.boiler_flame_current,sensor.boiler_flamecurr,6,0,1/10,256,1 -"Cascade CM10",boiler,81,fanwork,fan,boolean, ,false,binary_sensor.boiler_fan,binary_sensor.boiler_fanwork,6,0,1,257,1 -"Cascade CM10",boiler,81,ignwork,ignition,boolean, ,false,binary_sensor.boiler_ignition,binary_sensor.boiler_ignwork,6,0,1,258,1 -"Cascade CM10",boiler,81,oilpreheat,oil preheating,boolean, ,false,binary_sensor.boiler_oil_preheating,binary_sensor.boiler_oilpreheat,6,0,1,259,1 -"Cascade CM10",boiler,81,burnminpower,burner min power,uint8 (>=0<=0),%,true,number.boiler_burner_min_power,number.boiler_burnminpower,6,0,1,260,1 -"Cascade CM10",boiler,81,burnmaxpower,burner max power,uint8 (>=0<=254),%,true,number.boiler_burner_max_power,number.boiler_burnmaxpower,6,0,1,261,1 -"Cascade CM10",boiler,81,burnminperiod,burner min period,uint8 (>=0<=120),minutes,true,number.boiler_burner_min_period,number.boiler_burnminperiod,6,0,1,262,1 -"Cascade CM10",boiler,81,absburnpow,burner current power (absolute),uint8,%,false,sensor.boiler_burner_current_power_(absolute),sensor.boiler_absburnpow,6,0,1,263,1 -"Cascade CM10",boiler,81,heatblock,Heatblock temperature,uint16,C,false,sensor.boiler_Heatblock_temperature,sensor.boiler_heatblock,6,0,1/10,264,1 -"Cascade CM10",boiler,81,boilhyston,hysteresis on temperature,int8 (>=-20<=0),C,true,number.boiler_hysteresis_on_temperature,number.boiler_boilhyston,6,0,1,265,1 -"Cascade CM10",boiler,81,boilhystoff,hysteresis off temperature,int8 (>=0<=20),C,true,number.boiler_hysteresis_off_temperature,number.boiler_boilhystoff,6,0,1,266,1 -"Cascade CM10",boiler,81,boil2hyston,hysteresis stage 2 on temperature,int8 (>=-20<=0),C,true,number.boiler_hysteresis_stage_2_on_temperature,number.boiler_boil2hyston,6,0,1,267,1 -"Cascade CM10",boiler,81,boil2hystoff,hysteresis stage 2 off temperature,int8 (>=0<=20),C,true,number.boiler_hysteresis_stage_2_off_temperature,number.boiler_boil2hystoff,6,0,1,268,1 -"Cascade CM10",boiler,81,curveon,heatingcurve on,boolean (>=0<=0), ,true,switch.boiler_heatingcurve_on,switch.boiler_curveon,6,0,1,269,1 -"Cascade CM10",boiler,81,curvebase,heatingcurve base,uint8 (>=20<=90),C,true,number.boiler_heatingcurve_base,number.boiler_curvebase,6,0,1,270,1 -"Cascade CM10",boiler,81,curveend,heatingcurve end,uint8 (>=20<=90),C,true,number.boiler_heatingcurve_end,number.boiler_curveend,6,0,1,271,1 -"Cascade CM10",boiler,81,summertemp,summer temperature,uint8 (>=0<=45),C,true,number.boiler_summer_temperature,number.boiler_summertemp,6,0,1,272,1 -"Cascade CM10",boiler,81,nofrostmode,nofrost mode,boolean (>=0<=0), ,true,switch.boiler_nofrost_mode,switch.boiler_nofrostmode,6,0,1,273,1 -"Cascade CM10",boiler,81,nofrosttemp,nofrost temperature,uint8 (>=0<=10),C,true,number.boiler_nofrost_temperature,number.boiler_nofrosttemp,6,0,1,274,1 +"Cascade CM10",boiler,81,exhausttemp,exhaust temperature,uint16,C,false,sensor.boiler_exhaust_temperature,sensor.boiler_exhausttemp,6,0,1/10,254,1 +"Cascade CM10",boiler,81,burngas,gas,boolean, ,false,binary_sensor.boiler_gas,binary_sensor.boiler_burngas,6,0,1,255,1 +"Cascade CM10",boiler,81,burngas2,gas stage 2,boolean, ,false,binary_sensor.boiler_gas_stage_2,binary_sensor.boiler_burngas2,6,0,1,256,1 +"Cascade CM10",boiler,81,flamecurr,flame current,uint16,µA,false,sensor.boiler_flame_current,sensor.boiler_flamecurr,6,0,1/10,257,1 +"Cascade CM10",boiler,81,fanwork,fan,boolean, ,false,binary_sensor.boiler_fan,binary_sensor.boiler_fanwork,6,0,1,258,1 +"Cascade CM10",boiler,81,ignwork,ignition,boolean, ,false,binary_sensor.boiler_ignition,binary_sensor.boiler_ignwork,6,0,1,259,1 +"Cascade CM10",boiler,81,oilpreheat,oil preheating,boolean, ,false,binary_sensor.boiler_oil_preheating,binary_sensor.boiler_oilpreheat,6,0,1,260,1 +"Cascade CM10",boiler,81,burnminpower,burner min power,uint8 (>=0<=0),%,true,number.boiler_burner_min_power,number.boiler_burnminpower,6,0,1,261,1 +"Cascade CM10",boiler,81,burnmaxpower,burner max power,uint8 (>=0<=254),%,true,number.boiler_burner_max_power,number.boiler_burnmaxpower,6,0,1,262,1 +"Cascade CM10",boiler,81,burnminperiod,burner min period,uint8 (>=0<=120),minutes,true,number.boiler_burner_min_period,number.boiler_burnminperiod,6,0,1,263,1 +"Cascade CM10",boiler,81,absburnpow,burner current power (absolute),uint8,%,false,sensor.boiler_burner_current_power_(absolute),sensor.boiler_absburnpow,6,0,1,264,1 +"Cascade CM10",boiler,81,heatblock,Heatblock temperature,uint16,C,false,sensor.boiler_Heatblock_temperature,sensor.boiler_heatblock,6,0,1/10,265,1 +"Cascade CM10",boiler,81,boilhyston,hysteresis on temperature,int8 (>=-20<=0),C,true,number.boiler_hysteresis_on_temperature,number.boiler_boilhyston,6,0,1,266,1 +"Cascade CM10",boiler,81,boilhystoff,hysteresis off temperature,int8 (>=0<=20),C,true,number.boiler_hysteresis_off_temperature,number.boiler_boilhystoff,6,0,1,267,1 +"Cascade CM10",boiler,81,boil2hyston,hysteresis stage 2 on temperature,int8 (>=-20<=0),C,true,number.boiler_hysteresis_stage_2_on_temperature,number.boiler_boil2hyston,6,0,1,268,1 +"Cascade CM10",boiler,81,boil2hystoff,hysteresis stage 2 off temperature,int8 (>=0<=20),C,true,number.boiler_hysteresis_stage_2_off_temperature,number.boiler_boil2hystoff,6,0,1,269,1 +"Cascade CM10",boiler,81,curveon,heatingcurve on,boolean (>=0<=0), ,true,switch.boiler_heatingcurve_on,switch.boiler_curveon,6,0,1,270,1 +"Cascade CM10",boiler,81,curvebase,heatingcurve base,uint8 (>=20<=90),C,true,number.boiler_heatingcurve_base,number.boiler_curvebase,6,0,1,271,1 +"Cascade CM10",boiler,81,curveend,heatingcurve end,uint8 (>=20<=90),C,true,number.boiler_heatingcurve_end,number.boiler_curveend,6,0,1,272,1 +"Cascade CM10",boiler,81,summertemp,summer temperature,uint8 (>=0<=45),C,true,number.boiler_summer_temperature,number.boiler_summertemp,6,0,1,273,1 +"Cascade CM10",boiler,81,nofrostmode,nofrost mode,boolean (>=0<=0), ,true,switch.boiler_nofrost_mode,switch.boiler_nofrostmode,6,0,1,274,1 +"Cascade CM10",boiler,81,nofrosttemp,nofrost temperature,uint8 (>=0<=10),C,true,number.boiler_nofrost_temperature,number.boiler_nofrosttemp,6,0,1,275,1 "Cascade CM10",boiler,81,heatingactivated,heating activated,boolean (>=0<=0), ,true,switch.boiler_heating_activated,switch.boiler_heatingactivated,6,0,1,14,1 "Cascade CM10",boiler,81,heatingtemp,heating temperature,uint8 (>=0<=90),C,true,number.boiler_heating_temperature,number.boiler_heatingtemp,6,0,1,15,1 "Cascade CM10",boiler,81,heatingpump,heating pump,boolean, ,false,binary_sensor.boiler_heating_pump,binary_sensor.boiler_heatingpump,6,0,1,16,1 @@ -879,18 +885,19 @@ device name,device type,product id,shortname,fullname,type [options...] \| (min/ "Cascade CM10",boiler,81,maintenancedate,next maintenance date,string (>=0<=0), ,true,sensor.boiler_next_maintenance_date,sensor.boiler_maintenancedate,6,0,1,72,6 "Cascade CM10",boiler,81,emergencyops,emergency operation,boolean (>=0<=0), ,true,switch.boiler_emergency_operation,switch.boiler_emergencyops,6,0,1,78,1 "Cascade CM10",boiler,81,emergencytemp,emergency temperature,uint8 (>=15<=70),C,true,number.boiler_emergency_temperature,number.boiler_emergencytemp,6,0,1,79,1 -"Cascade CM10",boiler,81,pc0flow,Flow PC0,int16,l/h,false,sensor.boiler_Flow_PC0,sensor.boiler_pc0flow,6,0,1,80,1 -"Cascade CM10",boiler,81,pc1flow,Flow PC1,int16,l/h,false,sensor.boiler_Flow_PC1,sensor.boiler_pc1flow,6,0,1,81,1 -"Cascade CM10",boiler,81,pc1on,PC1,boolean, ,false,binary_sensor.boiler_PC1,binary_sensor.boiler_pc1on,6,0,1,82,1 -"Cascade CM10",boiler,81,pc1rate,PC1 rate,uint8,%,false,sensor.boiler_PC1_rate,sensor.boiler_pc1rate,6,0,1,83,1 -"Cascade CM10",boiler,81,pumpkickhour,pump kick hour,uint8 (>=0<=23),hours,true,number.boiler_pump_kick_hour,number.boiler_pumpkickhour,6,0,1,84,1 -"Cascade CM10",boiler,81,pumpkickday,pump kick day,enum [mo\|tu\|we\|th\|fr\|sa\|su\|all] (>=0<=0), ,true,select.boiler_pump_kick_day,select.boiler_pumpkickday,6,0,1,85,1 -"Cascade CM10",boiler,81,pumpkickdelay,pump kick delay,uint16 (>=0<=32767),minutes,true,number.boiler_pump_kick_delay,number.boiler_pumpkickdelay,6,0,1,86,1 -"Cascade CM10",boiler,81,meterheat,meter heating,uint24,kWh,false,sensor.boiler_meter_heating,sensor.boiler_meterheat,6,0,1/10,100,2 +"Cascade CM10",boiler,81,pc0lpm,Flow PC0,uint16,l/min,false,sensor.boiler_Flow_PC0,sensor.boiler_pc0lpm,6,0,1/10,80,1 +"Cascade CM10",boiler,81,pc0flow,Flow PC0,uint16,l/h,false,sensor.boiler_Flow_PC0,sensor.boiler_pc0flow,6,0,1,81,1 +"Cascade CM10",boiler,81,pc1flow,Flow PC1,uint16,l/h,false,sensor.boiler_Flow_PC1,sensor.boiler_pc1flow,6,0,1,82,1 +"Cascade CM10",boiler,81,pc1on,PC1,boolean, ,false,binary_sensor.boiler_PC1,binary_sensor.boiler_pc1on,6,0,1,83,1 +"Cascade CM10",boiler,81,pc1rate,PC1 rate,uint8,%,false,sensor.boiler_PC1_rate,sensor.boiler_pc1rate,6,0,1,84,1 +"Cascade CM10",boiler,81,pumpkickhour,pump kick hour,uint8 (>=0<=23),hours,true,number.boiler_pump_kick_hour,number.boiler_pumpkickhour,6,0,1,85,1 +"Cascade CM10",boiler,81,pumpkickday,pump kick day,enum [mo\|tu\|we\|th\|fr\|sa\|su\|all] (>=0<=0), ,true,select.boiler_pump_kick_day,select.boiler_pumpkickday,6,0,1,86,1 +"Cascade CM10",boiler,81,pumpkickdelay,pump kick delay,uint16 (>=0<=32767),minutes,true,number.boiler_pump_kick_delay,number.boiler_pumpkickdelay,6,0,1,87,1 +"Cascade CM10",boiler,81,meterheat,meter heating,uint24,kWh,false,sensor.boiler_meter_heating,sensor.boiler_meterheat,6,0,1/10,101,2 "Cascade CM10",boiler,81,dhw.meter,meter,uint24,kWh,false,sensor.boiler_dhw_meter,sensor.boiler_dhw_meter,6,9,1/10,2,2 -"Cascade CM10",boiler,81,gasmeterheat,gas meter heating,uint24,kWh,false,sensor.boiler_gas_meter_heating,sensor.boiler_gasmeterheat,6,0,1/10,275,2 +"Cascade CM10",boiler,81,gasmeterheat,gas meter heating,uint24,kWh,false,sensor.boiler_gas_meter_heating,sensor.boiler_gasmeterheat,6,0,1/10,276,2 "Cascade CM10",boiler,81,dhw.gasmeter,gas meter,uint24,kWh,false,sensor.boiler_dhw_gas_meter,sensor.boiler_dhw_gasmeter,6,9,1/10,71,2 -"Cascade CM10",boiler,81,nrgheat2,energy heating 2,uint24,kWh,false,sensor.boiler_energy_heating_2,sensor.boiler_nrgheat2,6,0,1/10,277,2 +"Cascade CM10",boiler,81,nrgheat2,energy heating 2,uint24,kWh,false,sensor.boiler_energy_heating_2,sensor.boiler_nrgheat2,6,0,1/10,278,2 "Cascade CM10",boiler,81,dhw.nrg2,energy 2,uint24,kWh,false,sensor.boiler_dhw_energy_2,sensor.boiler_dhw_nrg2,6,9,1/10,73,2 "Cascade CM10",boiler,81,dhw.tapactivated,turn on/off,boolean (>=0<=0), ,true,switch.boiler_dhw_turn_on/off,switch.boiler_dhw_tapactivated,6,9,1,28,1 "Cascade CM10",boiler,81,dhw.settemp,set temperature,uint8,C,false,sensor.boiler_dhw_set_temperature,sensor.boiler_dhw_settemp,6,9,1,29,1 @@ -933,9 +940,9 @@ device name,device type,product id,shortname,fullname,type [options...] \| (min/ "Cascade CM10",boiler,81,dhw.dhwprio,dhw priority,boolean (>=0<=0), ,true,switch.boiler_dhw_dhw_priority,switch.boiler_dhw_dhwprio,6,9,1,66,1 "Cascade CM10",boiler,81,dhw.starts,starts,uint24, ,false,sensor.boiler_dhw_starts,sensor.boiler_dhw_starts,6,9,1,67,2 "Cascade CM10",boiler,81,dhw.workm,active time,time,minutes,false,sensor.boiler_dhw_active_time,sensor.boiler_dhw_workm,6,9,1,69,2 -"Cascade CM10",boiler,81,nompower,nominal Power,uint8 (>=0<=0),kW,true,number.boiler_nominal_Power,number.boiler_nompower,6,0,1,279,1 -"Cascade CM10",boiler,81,nrgtotal,total energy,uint24,kWh,false,sensor.boiler_total_energy,sensor.boiler_nrgtotal,6,0,1/100,88,2 -"Cascade CM10",boiler,81,nrgheat,energy heating,uint24 (>=0<=10000000),kWh,true,number.boiler_energy_heating,number.boiler_nrgheat,6,0,1/100,90,2 +"Cascade CM10",boiler,81,nompower,nominal Power,uint8 (>=0<=0),kW,true,number.boiler_nominal_Power,number.boiler_nompower,6,0,1,280,1 +"Cascade CM10",boiler,81,nrgtotal,total energy,uint24,kWh,false,sensor.boiler_total_energy,sensor.boiler_nrgtotal,6,0,1/100,89,2 +"Cascade CM10",boiler,81,nrgheat,energy heating,uint24 (>=0<=10000000),kWh,true,number.boiler_energy_heating,number.boiler_nrgheat,6,0,1/100,91,2 "Cascade CM10",boiler,81,dhw.nrg,energy,uint24 (>=0<=10000000),kWh,true,number.boiler_dhw_energy,number.boiler_dhw_nrg,6,9,1/100,0,2 "Logamax Plus GB022",boiler,84,reset,reset,cmd [-\|maintenance\|error\|history\|message\|hp error\|burner starts\|factory] (>=0<=0), ,true,sensor.boiler_reset,sensor.boiler_reset,6,0,1,0,1 "Logamax Plus GB022",boiler,84,chimneysweeper,chimney sweeper,cmd [off\|on] (>=0<=0), ,true,sensor.boiler_chimney_sweeper,sensor.boiler_chimneysweeper,6,0,1,1,1 @@ -951,28 +958,28 @@ device name,device type,product id,shortname,fullname,type [options...] \| (min/ "Logamax Plus GB022",boiler,84,syspress,system pressure,uint8,bar,false,sensor.boiler_system_pressure,sensor.boiler_syspress,6,0,1/10,11,1 "Logamax Plus GB022",boiler,84,boiltemp,actual boiler temperature,uint16,C,false,sensor.boiler_actual_boiler_temperature,sensor.boiler_boiltemp,6,0,1/10,12,1 "Logamax Plus GB022",boiler,84,headertemp,low loss header,uint16,C,false,sensor.boiler_low_loss_header,sensor.boiler_headertemp,6,0,1/10,13,1 -"Logamax Plus GB022",boiler,84,exhausttemp,exhaust temperature,uint16,C,false,sensor.boiler_exhaust_temperature,sensor.boiler_exhausttemp,6,0,1/10,253,1 -"Logamax Plus GB022",boiler,84,burngas,gas,boolean, ,false,binary_sensor.boiler_gas,binary_sensor.boiler_burngas,6,0,1,254,1 -"Logamax Plus GB022",boiler,84,burngas2,gas stage 2,boolean, ,false,binary_sensor.boiler_gas_stage_2,binary_sensor.boiler_burngas2,6,0,1,255,1 -"Logamax Plus GB022",boiler,84,flamecurr,flame current,uint16,µA,false,sensor.boiler_flame_current,sensor.boiler_flamecurr,6,0,1/10,256,1 -"Logamax Plus GB022",boiler,84,fanwork,fan,boolean, ,false,binary_sensor.boiler_fan,binary_sensor.boiler_fanwork,6,0,1,257,1 -"Logamax Plus GB022",boiler,84,ignwork,ignition,boolean, ,false,binary_sensor.boiler_ignition,binary_sensor.boiler_ignwork,6,0,1,258,1 -"Logamax Plus GB022",boiler,84,oilpreheat,oil preheating,boolean, ,false,binary_sensor.boiler_oil_preheating,binary_sensor.boiler_oilpreheat,6,0,1,259,1 -"Logamax Plus GB022",boiler,84,burnminpower,burner min power,uint8 (>=0<=0),%,true,number.boiler_burner_min_power,number.boiler_burnminpower,6,0,1,260,1 -"Logamax Plus GB022",boiler,84,burnmaxpower,burner max power,uint8 (>=0<=254),%,true,number.boiler_burner_max_power,number.boiler_burnmaxpower,6,0,1,261,1 -"Logamax Plus GB022",boiler,84,burnminperiod,burner min period,uint8 (>=0<=120),minutes,true,number.boiler_burner_min_period,number.boiler_burnminperiod,6,0,1,262,1 -"Logamax Plus GB022",boiler,84,absburnpow,burner current power (absolute),uint8,%,false,sensor.boiler_burner_current_power_(absolute),sensor.boiler_absburnpow,6,0,1,263,1 -"Logamax Plus GB022",boiler,84,heatblock,Heatblock temperature,uint16,C,false,sensor.boiler_Heatblock_temperature,sensor.boiler_heatblock,6,0,1/10,264,1 -"Logamax Plus GB022",boiler,84,boilhyston,hysteresis on temperature,int8 (>=-20<=0),C,true,number.boiler_hysteresis_on_temperature,number.boiler_boilhyston,6,0,1,265,1 -"Logamax Plus GB022",boiler,84,boilhystoff,hysteresis off temperature,int8 (>=0<=20),C,true,number.boiler_hysteresis_off_temperature,number.boiler_boilhystoff,6,0,1,266,1 -"Logamax Plus GB022",boiler,84,boil2hyston,hysteresis stage 2 on temperature,int8 (>=-20<=0),C,true,number.boiler_hysteresis_stage_2_on_temperature,number.boiler_boil2hyston,6,0,1,267,1 -"Logamax Plus GB022",boiler,84,boil2hystoff,hysteresis stage 2 off temperature,int8 (>=0<=20),C,true,number.boiler_hysteresis_stage_2_off_temperature,number.boiler_boil2hystoff,6,0,1,268,1 -"Logamax Plus GB022",boiler,84,curveon,heatingcurve on,boolean (>=0<=0), ,true,switch.boiler_heatingcurve_on,switch.boiler_curveon,6,0,1,269,1 -"Logamax Plus GB022",boiler,84,curvebase,heatingcurve base,uint8 (>=20<=90),C,true,number.boiler_heatingcurve_base,number.boiler_curvebase,6,0,1,270,1 -"Logamax Plus GB022",boiler,84,curveend,heatingcurve end,uint8 (>=20<=90),C,true,number.boiler_heatingcurve_end,number.boiler_curveend,6,0,1,271,1 -"Logamax Plus GB022",boiler,84,summertemp,summer temperature,uint8 (>=0<=45),C,true,number.boiler_summer_temperature,number.boiler_summertemp,6,0,1,272,1 -"Logamax Plus GB022",boiler,84,nofrostmode,nofrost mode,boolean (>=0<=0), ,true,switch.boiler_nofrost_mode,switch.boiler_nofrostmode,6,0,1,273,1 -"Logamax Plus GB022",boiler,84,nofrosttemp,nofrost temperature,uint8 (>=0<=10),C,true,number.boiler_nofrost_temperature,number.boiler_nofrosttemp,6,0,1,274,1 +"Logamax Plus GB022",boiler,84,exhausttemp,exhaust temperature,uint16,C,false,sensor.boiler_exhaust_temperature,sensor.boiler_exhausttemp,6,0,1/10,254,1 +"Logamax Plus GB022",boiler,84,burngas,gas,boolean, ,false,binary_sensor.boiler_gas,binary_sensor.boiler_burngas,6,0,1,255,1 +"Logamax Plus GB022",boiler,84,burngas2,gas stage 2,boolean, ,false,binary_sensor.boiler_gas_stage_2,binary_sensor.boiler_burngas2,6,0,1,256,1 +"Logamax Plus GB022",boiler,84,flamecurr,flame current,uint16,µA,false,sensor.boiler_flame_current,sensor.boiler_flamecurr,6,0,1/10,257,1 +"Logamax Plus GB022",boiler,84,fanwork,fan,boolean, ,false,binary_sensor.boiler_fan,binary_sensor.boiler_fanwork,6,0,1,258,1 +"Logamax Plus GB022",boiler,84,ignwork,ignition,boolean, ,false,binary_sensor.boiler_ignition,binary_sensor.boiler_ignwork,6,0,1,259,1 +"Logamax Plus GB022",boiler,84,oilpreheat,oil preheating,boolean, ,false,binary_sensor.boiler_oil_preheating,binary_sensor.boiler_oilpreheat,6,0,1,260,1 +"Logamax Plus GB022",boiler,84,burnminpower,burner min power,uint8 (>=0<=0),%,true,number.boiler_burner_min_power,number.boiler_burnminpower,6,0,1,261,1 +"Logamax Plus GB022",boiler,84,burnmaxpower,burner max power,uint8 (>=0<=254),%,true,number.boiler_burner_max_power,number.boiler_burnmaxpower,6,0,1,262,1 +"Logamax Plus GB022",boiler,84,burnminperiod,burner min period,uint8 (>=0<=120),minutes,true,number.boiler_burner_min_period,number.boiler_burnminperiod,6,0,1,263,1 +"Logamax Plus GB022",boiler,84,absburnpow,burner current power (absolute),uint8,%,false,sensor.boiler_burner_current_power_(absolute),sensor.boiler_absburnpow,6,0,1,264,1 +"Logamax Plus GB022",boiler,84,heatblock,Heatblock temperature,uint16,C,false,sensor.boiler_Heatblock_temperature,sensor.boiler_heatblock,6,0,1/10,265,1 +"Logamax Plus GB022",boiler,84,boilhyston,hysteresis on temperature,int8 (>=-20<=0),C,true,number.boiler_hysteresis_on_temperature,number.boiler_boilhyston,6,0,1,266,1 +"Logamax Plus GB022",boiler,84,boilhystoff,hysteresis off temperature,int8 (>=0<=20),C,true,number.boiler_hysteresis_off_temperature,number.boiler_boilhystoff,6,0,1,267,1 +"Logamax Plus GB022",boiler,84,boil2hyston,hysteresis stage 2 on temperature,int8 (>=-20<=0),C,true,number.boiler_hysteresis_stage_2_on_temperature,number.boiler_boil2hyston,6,0,1,268,1 +"Logamax Plus GB022",boiler,84,boil2hystoff,hysteresis stage 2 off temperature,int8 (>=0<=20),C,true,number.boiler_hysteresis_stage_2_off_temperature,number.boiler_boil2hystoff,6,0,1,269,1 +"Logamax Plus GB022",boiler,84,curveon,heatingcurve on,boolean (>=0<=0), ,true,switch.boiler_heatingcurve_on,switch.boiler_curveon,6,0,1,270,1 +"Logamax Plus GB022",boiler,84,curvebase,heatingcurve base,uint8 (>=20<=90),C,true,number.boiler_heatingcurve_base,number.boiler_curvebase,6,0,1,271,1 +"Logamax Plus GB022",boiler,84,curveend,heatingcurve end,uint8 (>=20<=90),C,true,number.boiler_heatingcurve_end,number.boiler_curveend,6,0,1,272,1 +"Logamax Plus GB022",boiler,84,summertemp,summer temperature,uint8 (>=0<=45),C,true,number.boiler_summer_temperature,number.boiler_summertemp,6,0,1,273,1 +"Logamax Plus GB022",boiler,84,nofrostmode,nofrost mode,boolean (>=0<=0), ,true,switch.boiler_nofrost_mode,switch.boiler_nofrostmode,6,0,1,274,1 +"Logamax Plus GB022",boiler,84,nofrosttemp,nofrost temperature,uint8 (>=0<=10),C,true,number.boiler_nofrost_temperature,number.boiler_nofrosttemp,6,0,1,275,1 "Logamax Plus GB022",boiler,84,heatingactivated,heating activated,boolean (>=0<=0), ,true,switch.boiler_heating_activated,switch.boiler_heatingactivated,6,0,1,14,1 "Logamax Plus GB022",boiler,84,heatingtemp,heating temperature,uint8 (>=0<=90),C,true,number.boiler_heating_temperature,number.boiler_heatingtemp,6,0,1,15,1 "Logamax Plus GB022",boiler,84,heatingpump,heating pump,boolean, ,false,binary_sensor.boiler_heating_pump,binary_sensor.boiler_heatingpump,6,0,1,16,1 @@ -999,18 +1006,19 @@ device name,device type,product id,shortname,fullname,type [options...] \| (min/ "Logamax Plus GB022",boiler,84,maintenancedate,next maintenance date,string (>=0<=0), ,true,sensor.boiler_next_maintenance_date,sensor.boiler_maintenancedate,6,0,1,72,6 "Logamax Plus GB022",boiler,84,emergencyops,emergency operation,boolean (>=0<=0), ,true,switch.boiler_emergency_operation,switch.boiler_emergencyops,6,0,1,78,1 "Logamax Plus GB022",boiler,84,emergencytemp,emergency temperature,uint8 (>=15<=70),C,true,number.boiler_emergency_temperature,number.boiler_emergencytemp,6,0,1,79,1 -"Logamax Plus GB022",boiler,84,pc0flow,Flow PC0,int16,l/h,false,sensor.boiler_Flow_PC0,sensor.boiler_pc0flow,6,0,1,80,1 -"Logamax Plus GB022",boiler,84,pc1flow,Flow PC1,int16,l/h,false,sensor.boiler_Flow_PC1,sensor.boiler_pc1flow,6,0,1,81,1 -"Logamax Plus GB022",boiler,84,pc1on,PC1,boolean, ,false,binary_sensor.boiler_PC1,binary_sensor.boiler_pc1on,6,0,1,82,1 -"Logamax Plus GB022",boiler,84,pc1rate,PC1 rate,uint8,%,false,sensor.boiler_PC1_rate,sensor.boiler_pc1rate,6,0,1,83,1 -"Logamax Plus GB022",boiler,84,pumpkickhour,pump kick hour,uint8 (>=0<=23),hours,true,number.boiler_pump_kick_hour,number.boiler_pumpkickhour,6,0,1,84,1 -"Logamax Plus GB022",boiler,84,pumpkickday,pump kick day,enum [mo\|tu\|we\|th\|fr\|sa\|su\|all] (>=0<=0), ,true,select.boiler_pump_kick_day,select.boiler_pumpkickday,6,0,1,85,1 -"Logamax Plus GB022",boiler,84,pumpkickdelay,pump kick delay,uint16 (>=0<=32767),minutes,true,number.boiler_pump_kick_delay,number.boiler_pumpkickdelay,6,0,1,86,1 -"Logamax Plus GB022",boiler,84,meterheat,meter heating,uint24,kWh,false,sensor.boiler_meter_heating,sensor.boiler_meterheat,6,0,1/10,100,2 +"Logamax Plus GB022",boiler,84,pc0lpm,Flow PC0,uint16,l/min,false,sensor.boiler_Flow_PC0,sensor.boiler_pc0lpm,6,0,1/10,80,1 +"Logamax Plus GB022",boiler,84,pc0flow,Flow PC0,uint16,l/h,false,sensor.boiler_Flow_PC0,sensor.boiler_pc0flow,6,0,1,81,1 +"Logamax Plus GB022",boiler,84,pc1flow,Flow PC1,uint16,l/h,false,sensor.boiler_Flow_PC1,sensor.boiler_pc1flow,6,0,1,82,1 +"Logamax Plus GB022",boiler,84,pc1on,PC1,boolean, ,false,binary_sensor.boiler_PC1,binary_sensor.boiler_pc1on,6,0,1,83,1 +"Logamax Plus GB022",boiler,84,pc1rate,PC1 rate,uint8,%,false,sensor.boiler_PC1_rate,sensor.boiler_pc1rate,6,0,1,84,1 +"Logamax Plus GB022",boiler,84,pumpkickhour,pump kick hour,uint8 (>=0<=23),hours,true,number.boiler_pump_kick_hour,number.boiler_pumpkickhour,6,0,1,85,1 +"Logamax Plus GB022",boiler,84,pumpkickday,pump kick day,enum [mo\|tu\|we\|th\|fr\|sa\|su\|all] (>=0<=0), ,true,select.boiler_pump_kick_day,select.boiler_pumpkickday,6,0,1,86,1 +"Logamax Plus GB022",boiler,84,pumpkickdelay,pump kick delay,uint16 (>=0<=32767),minutes,true,number.boiler_pump_kick_delay,number.boiler_pumpkickdelay,6,0,1,87,1 +"Logamax Plus GB022",boiler,84,meterheat,meter heating,uint24,kWh,false,sensor.boiler_meter_heating,sensor.boiler_meterheat,6,0,1/10,101,2 "Logamax Plus GB022",boiler,84,dhw.meter,meter,uint24,kWh,false,sensor.boiler_dhw_meter,sensor.boiler_dhw_meter,6,9,1/10,2,2 -"Logamax Plus GB022",boiler,84,gasmeterheat,gas meter heating,uint24,kWh,false,sensor.boiler_gas_meter_heating,sensor.boiler_gasmeterheat,6,0,1/10,275,2 +"Logamax Plus GB022",boiler,84,gasmeterheat,gas meter heating,uint24,kWh,false,sensor.boiler_gas_meter_heating,sensor.boiler_gasmeterheat,6,0,1/10,276,2 "Logamax Plus GB022",boiler,84,dhw.gasmeter,gas meter,uint24,kWh,false,sensor.boiler_dhw_gas_meter,sensor.boiler_dhw_gasmeter,6,9,1/10,71,2 -"Logamax Plus GB022",boiler,84,nrgheat2,energy heating 2,uint24,kWh,false,sensor.boiler_energy_heating_2,sensor.boiler_nrgheat2,6,0,1/10,277,2 +"Logamax Plus GB022",boiler,84,nrgheat2,energy heating 2,uint24,kWh,false,sensor.boiler_energy_heating_2,sensor.boiler_nrgheat2,6,0,1/10,278,2 "Logamax Plus GB022",boiler,84,dhw.nrg2,energy 2,uint24,kWh,false,sensor.boiler_dhw_energy_2,sensor.boiler_dhw_nrg2,6,9,1/10,73,2 "Logamax Plus GB022",boiler,84,dhw.tapactivated,turn on/off,boolean (>=0<=0), ,true,switch.boiler_dhw_turn_on/off,switch.boiler_dhw_tapactivated,6,9,1,28,1 "Logamax Plus GB022",boiler,84,dhw.settemp,set temperature,uint8,C,false,sensor.boiler_dhw_set_temperature,sensor.boiler_dhw_settemp,6,9,1,29,1 @@ -1053,9 +1061,9 @@ device name,device type,product id,shortname,fullname,type [options...] \| (min/ "Logamax Plus GB022",boiler,84,dhw.dhwprio,dhw priority,boolean (>=0<=0), ,true,switch.boiler_dhw_dhw_priority,switch.boiler_dhw_dhwprio,6,9,1,66,1 "Logamax Plus GB022",boiler,84,dhw.starts,starts,uint24, ,false,sensor.boiler_dhw_starts,sensor.boiler_dhw_starts,6,9,1,67,2 "Logamax Plus GB022",boiler,84,dhw.workm,active time,time,minutes,false,sensor.boiler_dhw_active_time,sensor.boiler_dhw_workm,6,9,1,69,2 -"Logamax Plus GB022",boiler,84,nompower,nominal Power,uint8 (>=0<=0),kW,true,number.boiler_nominal_Power,number.boiler_nompower,6,0,1,279,1 -"Logamax Plus GB022",boiler,84,nrgtotal,total energy,uint24,kWh,false,sensor.boiler_total_energy,sensor.boiler_nrgtotal,6,0,1/100,88,2 -"Logamax Plus GB022",boiler,84,nrgheat,energy heating,uint24 (>=0<=10000000),kWh,true,number.boiler_energy_heating,number.boiler_nrgheat,6,0,1/100,90,2 +"Logamax Plus GB022",boiler,84,nompower,nominal Power,uint8 (>=0<=0),kW,true,number.boiler_nominal_Power,number.boiler_nompower,6,0,1,280,1 +"Logamax Plus GB022",boiler,84,nrgtotal,total energy,uint24,kWh,false,sensor.boiler_total_energy,sensor.boiler_nrgtotal,6,0,1/100,89,2 +"Logamax Plus GB022",boiler,84,nrgheat,energy heating,uint24 (>=0<=10000000),kWh,true,number.boiler_energy_heating,number.boiler_nrgheat,6,0,1/100,91,2 "Logamax Plus GB022",boiler,84,dhw.nrg,energy,uint24 (>=0<=10000000),kWh,true,number.boiler_dhw_energy,number.boiler_dhw_nrg,6,9,1/100,0,2 "Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3",boiler,95,reset,reset,cmd [-\|maintenance\|error\|history\|message\|hp error\|burner starts\|factory] (>=0<=0), ,true,sensor.boiler_reset,sensor.boiler_reset,6,0,1,0,1 "Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3",boiler,95,chimneysweeper,chimney sweeper,cmd [off\|on] (>=0<=0), ,true,sensor.boiler_chimney_sweeper,sensor.boiler_chimneysweeper,6,0,1,1,1 @@ -1071,28 +1079,28 @@ device name,device type,product id,shortname,fullname,type [options...] \| (min/ "Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3",boiler,95,syspress,system pressure,uint8,bar,false,sensor.boiler_system_pressure,sensor.boiler_syspress,6,0,1/10,11,1 "Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3",boiler,95,boiltemp,actual boiler temperature,uint16,C,false,sensor.boiler_actual_boiler_temperature,sensor.boiler_boiltemp,6,0,1/10,12,1 "Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3",boiler,95,headertemp,low loss header,uint16,C,false,sensor.boiler_low_loss_header,sensor.boiler_headertemp,6,0,1/10,13,1 -"Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3",boiler,95,exhausttemp,exhaust temperature,uint16,C,false,sensor.boiler_exhaust_temperature,sensor.boiler_exhausttemp,6,0,1/10,253,1 -"Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3",boiler,95,burngas,gas,boolean, ,false,binary_sensor.boiler_gas,binary_sensor.boiler_burngas,6,0,1,254,1 -"Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3",boiler,95,burngas2,gas stage 2,boolean, ,false,binary_sensor.boiler_gas_stage_2,binary_sensor.boiler_burngas2,6,0,1,255,1 -"Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3",boiler,95,flamecurr,flame current,uint16,µA,false,sensor.boiler_flame_current,sensor.boiler_flamecurr,6,0,1/10,256,1 -"Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3",boiler,95,fanwork,fan,boolean, ,false,binary_sensor.boiler_fan,binary_sensor.boiler_fanwork,6,0,1,257,1 -"Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3",boiler,95,ignwork,ignition,boolean, ,false,binary_sensor.boiler_ignition,binary_sensor.boiler_ignwork,6,0,1,258,1 -"Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3",boiler,95,oilpreheat,oil preheating,boolean, ,false,binary_sensor.boiler_oil_preheating,binary_sensor.boiler_oilpreheat,6,0,1,259,1 -"Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3",boiler,95,burnminpower,burner min power,uint8 (>=0<=0),%,true,number.boiler_burner_min_power,number.boiler_burnminpower,6,0,1,260,1 -"Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3",boiler,95,burnmaxpower,burner max power,uint8 (>=0<=254),%,true,number.boiler_burner_max_power,number.boiler_burnmaxpower,6,0,1,261,1 -"Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3",boiler,95,burnminperiod,burner min period,uint8 (>=0<=120),minutes,true,number.boiler_burner_min_period,number.boiler_burnminperiod,6,0,1,262,1 -"Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3",boiler,95,absburnpow,burner current power (absolute),uint8,%,false,sensor.boiler_burner_current_power_(absolute),sensor.boiler_absburnpow,6,0,1,263,1 -"Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3",boiler,95,heatblock,Heatblock temperature,uint16,C,false,sensor.boiler_Heatblock_temperature,sensor.boiler_heatblock,6,0,1/10,264,1 -"Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3",boiler,95,boilhyston,hysteresis on temperature,int8 (>=-20<=0),C,true,number.boiler_hysteresis_on_temperature,number.boiler_boilhyston,6,0,1,265,1 -"Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3",boiler,95,boilhystoff,hysteresis off temperature,int8 (>=0<=20),C,true,number.boiler_hysteresis_off_temperature,number.boiler_boilhystoff,6,0,1,266,1 -"Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3",boiler,95,boil2hyston,hysteresis stage 2 on temperature,int8 (>=-20<=0),C,true,number.boiler_hysteresis_stage_2_on_temperature,number.boiler_boil2hyston,6,0,1,267,1 -"Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3",boiler,95,boil2hystoff,hysteresis stage 2 off temperature,int8 (>=0<=20),C,true,number.boiler_hysteresis_stage_2_off_temperature,number.boiler_boil2hystoff,6,0,1,268,1 -"Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3",boiler,95,curveon,heatingcurve on,boolean (>=0<=0), ,true,switch.boiler_heatingcurve_on,switch.boiler_curveon,6,0,1,269,1 -"Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3",boiler,95,curvebase,heatingcurve base,uint8 (>=20<=90),C,true,number.boiler_heatingcurve_base,number.boiler_curvebase,6,0,1,270,1 -"Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3",boiler,95,curveend,heatingcurve end,uint8 (>=20<=90),C,true,number.boiler_heatingcurve_end,number.boiler_curveend,6,0,1,271,1 -"Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3",boiler,95,summertemp,summer temperature,uint8 (>=0<=45),C,true,number.boiler_summer_temperature,number.boiler_summertemp,6,0,1,272,1 -"Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3",boiler,95,nofrostmode,nofrost mode,boolean (>=0<=0), ,true,switch.boiler_nofrost_mode,switch.boiler_nofrostmode,6,0,1,273,1 -"Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3",boiler,95,nofrosttemp,nofrost temperature,uint8 (>=0<=10),C,true,number.boiler_nofrost_temperature,number.boiler_nofrosttemp,6,0,1,274,1 +"Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3",boiler,95,exhausttemp,exhaust temperature,uint16,C,false,sensor.boiler_exhaust_temperature,sensor.boiler_exhausttemp,6,0,1/10,254,1 +"Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3",boiler,95,burngas,gas,boolean, ,false,binary_sensor.boiler_gas,binary_sensor.boiler_burngas,6,0,1,255,1 +"Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3",boiler,95,burngas2,gas stage 2,boolean, ,false,binary_sensor.boiler_gas_stage_2,binary_sensor.boiler_burngas2,6,0,1,256,1 +"Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3",boiler,95,flamecurr,flame current,uint16,µA,false,sensor.boiler_flame_current,sensor.boiler_flamecurr,6,0,1/10,257,1 +"Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3",boiler,95,fanwork,fan,boolean, ,false,binary_sensor.boiler_fan,binary_sensor.boiler_fanwork,6,0,1,258,1 +"Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3",boiler,95,ignwork,ignition,boolean, ,false,binary_sensor.boiler_ignition,binary_sensor.boiler_ignwork,6,0,1,259,1 +"Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3",boiler,95,oilpreheat,oil preheating,boolean, ,false,binary_sensor.boiler_oil_preheating,binary_sensor.boiler_oilpreheat,6,0,1,260,1 +"Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3",boiler,95,burnminpower,burner min power,uint8 (>=0<=0),%,true,number.boiler_burner_min_power,number.boiler_burnminpower,6,0,1,261,1 +"Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3",boiler,95,burnmaxpower,burner max power,uint8 (>=0<=254),%,true,number.boiler_burner_max_power,number.boiler_burnmaxpower,6,0,1,262,1 +"Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3",boiler,95,burnminperiod,burner min period,uint8 (>=0<=120),minutes,true,number.boiler_burner_min_period,number.boiler_burnminperiod,6,0,1,263,1 +"Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3",boiler,95,absburnpow,burner current power (absolute),uint8,%,false,sensor.boiler_burner_current_power_(absolute),sensor.boiler_absburnpow,6,0,1,264,1 +"Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3",boiler,95,heatblock,Heatblock temperature,uint16,C,false,sensor.boiler_Heatblock_temperature,sensor.boiler_heatblock,6,0,1/10,265,1 +"Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3",boiler,95,boilhyston,hysteresis on temperature,int8 (>=-20<=0),C,true,number.boiler_hysteresis_on_temperature,number.boiler_boilhyston,6,0,1,266,1 +"Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3",boiler,95,boilhystoff,hysteresis off temperature,int8 (>=0<=20),C,true,number.boiler_hysteresis_off_temperature,number.boiler_boilhystoff,6,0,1,267,1 +"Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3",boiler,95,boil2hyston,hysteresis stage 2 on temperature,int8 (>=-20<=0),C,true,number.boiler_hysteresis_stage_2_on_temperature,number.boiler_boil2hyston,6,0,1,268,1 +"Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3",boiler,95,boil2hystoff,hysteresis stage 2 off temperature,int8 (>=0<=20),C,true,number.boiler_hysteresis_stage_2_off_temperature,number.boiler_boil2hystoff,6,0,1,269,1 +"Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3",boiler,95,curveon,heatingcurve on,boolean (>=0<=0), ,true,switch.boiler_heatingcurve_on,switch.boiler_curveon,6,0,1,270,1 +"Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3",boiler,95,curvebase,heatingcurve base,uint8 (>=20<=90),C,true,number.boiler_heatingcurve_base,number.boiler_curvebase,6,0,1,271,1 +"Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3",boiler,95,curveend,heatingcurve end,uint8 (>=20<=90),C,true,number.boiler_heatingcurve_end,number.boiler_curveend,6,0,1,272,1 +"Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3",boiler,95,summertemp,summer temperature,uint8 (>=0<=45),C,true,number.boiler_summer_temperature,number.boiler_summertemp,6,0,1,273,1 +"Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3",boiler,95,nofrostmode,nofrost mode,boolean (>=0<=0), ,true,switch.boiler_nofrost_mode,switch.boiler_nofrostmode,6,0,1,274,1 +"Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3",boiler,95,nofrosttemp,nofrost temperature,uint8 (>=0<=10),C,true,number.boiler_nofrost_temperature,number.boiler_nofrosttemp,6,0,1,275,1 "Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3",boiler,95,heatingactivated,heating activated,boolean (>=0<=0), ,true,switch.boiler_heating_activated,switch.boiler_heatingactivated,6,0,1,14,1 "Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3",boiler,95,heatingtemp,heating temperature,uint8 (>=0<=90),C,true,number.boiler_heating_temperature,number.boiler_heatingtemp,6,0,1,15,1 "Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3",boiler,95,heatingpump,heating pump,boolean, ,false,binary_sensor.boiler_heating_pump,binary_sensor.boiler_heatingpump,6,0,1,16,1 @@ -1119,18 +1127,19 @@ device name,device type,product id,shortname,fullname,type [options...] \| (min/ "Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3",boiler,95,maintenancedate,next maintenance date,string (>=0<=0), ,true,sensor.boiler_next_maintenance_date,sensor.boiler_maintenancedate,6,0,1,72,6 "Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3",boiler,95,emergencyops,emergency operation,boolean (>=0<=0), ,true,switch.boiler_emergency_operation,switch.boiler_emergencyops,6,0,1,78,1 "Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3",boiler,95,emergencytemp,emergency temperature,uint8 (>=15<=70),C,true,number.boiler_emergency_temperature,number.boiler_emergencytemp,6,0,1,79,1 -"Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3",boiler,95,pc0flow,Flow PC0,int16,l/h,false,sensor.boiler_Flow_PC0,sensor.boiler_pc0flow,6,0,1,80,1 -"Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3",boiler,95,pc1flow,Flow PC1,int16,l/h,false,sensor.boiler_Flow_PC1,sensor.boiler_pc1flow,6,0,1,81,1 -"Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3",boiler,95,pc1on,PC1,boolean, ,false,binary_sensor.boiler_PC1,binary_sensor.boiler_pc1on,6,0,1,82,1 -"Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3",boiler,95,pc1rate,PC1 rate,uint8,%,false,sensor.boiler_PC1_rate,sensor.boiler_pc1rate,6,0,1,83,1 -"Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3",boiler,95,pumpkickhour,pump kick hour,uint8 (>=0<=23),hours,true,number.boiler_pump_kick_hour,number.boiler_pumpkickhour,6,0,1,84,1 -"Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3",boiler,95,pumpkickday,pump kick day,enum [mo\|tu\|we\|th\|fr\|sa\|su\|all] (>=0<=0), ,true,select.boiler_pump_kick_day,select.boiler_pumpkickday,6,0,1,85,1 -"Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3",boiler,95,pumpkickdelay,pump kick delay,uint16 (>=0<=32767),minutes,true,number.boiler_pump_kick_delay,number.boiler_pumpkickdelay,6,0,1,86,1 -"Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3",boiler,95,meterheat,meter heating,uint24,kWh,false,sensor.boiler_meter_heating,sensor.boiler_meterheat,6,0,1/10,100,2 +"Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3",boiler,95,pc0lpm,Flow PC0,uint16,l/min,false,sensor.boiler_Flow_PC0,sensor.boiler_pc0lpm,6,0,1/10,80,1 +"Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3",boiler,95,pc0flow,Flow PC0,uint16,l/h,false,sensor.boiler_Flow_PC0,sensor.boiler_pc0flow,6,0,1,81,1 +"Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3",boiler,95,pc1flow,Flow PC1,uint16,l/h,false,sensor.boiler_Flow_PC1,sensor.boiler_pc1flow,6,0,1,82,1 +"Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3",boiler,95,pc1on,PC1,boolean, ,false,binary_sensor.boiler_PC1,binary_sensor.boiler_pc1on,6,0,1,83,1 +"Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3",boiler,95,pc1rate,PC1 rate,uint8,%,false,sensor.boiler_PC1_rate,sensor.boiler_pc1rate,6,0,1,84,1 +"Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3",boiler,95,pumpkickhour,pump kick hour,uint8 (>=0<=23),hours,true,number.boiler_pump_kick_hour,number.boiler_pumpkickhour,6,0,1,85,1 +"Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3",boiler,95,pumpkickday,pump kick day,enum [mo\|tu\|we\|th\|fr\|sa\|su\|all] (>=0<=0), ,true,select.boiler_pump_kick_day,select.boiler_pumpkickday,6,0,1,86,1 +"Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3",boiler,95,pumpkickdelay,pump kick delay,uint16 (>=0<=32767),minutes,true,number.boiler_pump_kick_delay,number.boiler_pumpkickdelay,6,0,1,87,1 +"Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3",boiler,95,meterheat,meter heating,uint24,kWh,false,sensor.boiler_meter_heating,sensor.boiler_meterheat,6,0,1/10,101,2 "Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3",boiler,95,dhw.meter,meter,uint24,kWh,false,sensor.boiler_dhw_meter,sensor.boiler_dhw_meter,6,9,1/10,2,2 -"Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3",boiler,95,gasmeterheat,gas meter heating,uint24,kWh,false,sensor.boiler_gas_meter_heating,sensor.boiler_gasmeterheat,6,0,1/10,275,2 +"Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3",boiler,95,gasmeterheat,gas meter heating,uint24,kWh,false,sensor.boiler_gas_meter_heating,sensor.boiler_gasmeterheat,6,0,1/10,276,2 "Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3",boiler,95,dhw.gasmeter,gas meter,uint24,kWh,false,sensor.boiler_dhw_gas_meter,sensor.boiler_dhw_gasmeter,6,9,1/10,71,2 -"Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3",boiler,95,nrgheat2,energy heating 2,uint24,kWh,false,sensor.boiler_energy_heating_2,sensor.boiler_nrgheat2,6,0,1/10,277,2 +"Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3",boiler,95,nrgheat2,energy heating 2,uint24,kWh,false,sensor.boiler_energy_heating_2,sensor.boiler_nrgheat2,6,0,1/10,278,2 "Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3",boiler,95,dhw.nrg2,energy 2,uint24,kWh,false,sensor.boiler_dhw_energy_2,sensor.boiler_dhw_nrg2,6,9,1/10,73,2 "Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3",boiler,95,dhw.tapactivated,turn on/off,boolean (>=0<=0), ,true,switch.boiler_dhw_turn_on/off,switch.boiler_dhw_tapactivated,6,9,1,28,1 "Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3",boiler,95,dhw.settemp,set temperature,uint8,C,false,sensor.boiler_dhw_set_temperature,sensor.boiler_dhw_settemp,6,9,1,29,1 @@ -1173,9 +1182,9 @@ device name,device type,product id,shortname,fullname,type [options...] \| (min/ "Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3",boiler,95,dhw.dhwprio,dhw priority,boolean (>=0<=0), ,true,switch.boiler_dhw_dhw_priority,switch.boiler_dhw_dhwprio,6,9,1,66,1 "Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3",boiler,95,dhw.starts,starts,uint24, ,false,sensor.boiler_dhw_starts,sensor.boiler_dhw_starts,6,9,1,67,2 "Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3",boiler,95,dhw.workm,active time,time,minutes,false,sensor.boiler_dhw_active_time,sensor.boiler_dhw_workm,6,9,1,69,2 -"Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3",boiler,95,nompower,nominal Power,uint8 (>=0<=0),kW,true,number.boiler_nominal_Power,number.boiler_nompower,6,0,1,279,1 -"Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3",boiler,95,nrgtotal,total energy,uint24,kWh,false,sensor.boiler_total_energy,sensor.boiler_nrgtotal,6,0,1/100,88,2 -"Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3",boiler,95,nrgheat,energy heating,uint24 (>=0<=10000000),kWh,true,number.boiler_energy_heating,number.boiler_nrgheat,6,0,1/100,90,2 +"Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3",boiler,95,nompower,nominal Power,uint8 (>=0<=0),kW,true,number.boiler_nominal_Power,number.boiler_nompower,6,0,1,280,1 +"Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3",boiler,95,nrgtotal,total energy,uint24,kWh,false,sensor.boiler_total_energy,sensor.boiler_nrgtotal,6,0,1/100,89,2 +"Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3",boiler,95,nrgheat,energy heating,uint24 (>=0<=10000000),kWh,true,number.boiler_energy_heating,number.boiler_nrgheat,6,0,1/100,91,2 "Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3",boiler,95,dhw.nrg,energy,uint24 (>=0<=10000000),kWh,true,number.boiler_dhw_energy,number.boiler_dhw_nrg,6,9,1/100,0,2 "Topline, GB162",boiler,115,reset,reset,cmd [-\|maintenance\|error\|history\|message\|hp error\|burner starts\|factory] (>=0<=0), ,true,sensor.boiler_reset,sensor.boiler_reset,6,0,1,0,1 "Topline, GB162",boiler,115,chimneysweeper,chimney sweeper,cmd [off\|on] (>=0<=0), ,true,sensor.boiler_chimney_sweeper,sensor.boiler_chimneysweeper,6,0,1,1,1 @@ -1191,28 +1200,28 @@ device name,device type,product id,shortname,fullname,type [options...] \| (min/ "Topline, GB162",boiler,115,syspress,system pressure,uint8,bar,false,sensor.boiler_system_pressure,sensor.boiler_syspress,6,0,1/10,11,1 "Topline, GB162",boiler,115,boiltemp,actual boiler temperature,uint16,C,false,sensor.boiler_actual_boiler_temperature,sensor.boiler_boiltemp,6,0,1/10,12,1 "Topline, GB162",boiler,115,headertemp,low loss header,uint16,C,false,sensor.boiler_low_loss_header,sensor.boiler_headertemp,6,0,1/10,13,1 -"Topline, GB162",boiler,115,exhausttemp,exhaust temperature,uint16,C,false,sensor.boiler_exhaust_temperature,sensor.boiler_exhausttemp,6,0,1/10,253,1 -"Topline, GB162",boiler,115,burngas,gas,boolean, ,false,binary_sensor.boiler_gas,binary_sensor.boiler_burngas,6,0,1,254,1 -"Topline, GB162",boiler,115,burngas2,gas stage 2,boolean, ,false,binary_sensor.boiler_gas_stage_2,binary_sensor.boiler_burngas2,6,0,1,255,1 -"Topline, GB162",boiler,115,flamecurr,flame current,uint16,µA,false,sensor.boiler_flame_current,sensor.boiler_flamecurr,6,0,1/10,256,1 -"Topline, GB162",boiler,115,fanwork,fan,boolean, ,false,binary_sensor.boiler_fan,binary_sensor.boiler_fanwork,6,0,1,257,1 -"Topline, GB162",boiler,115,ignwork,ignition,boolean, ,false,binary_sensor.boiler_ignition,binary_sensor.boiler_ignwork,6,0,1,258,1 -"Topline, GB162",boiler,115,oilpreheat,oil preheating,boolean, ,false,binary_sensor.boiler_oil_preheating,binary_sensor.boiler_oilpreheat,6,0,1,259,1 -"Topline, GB162",boiler,115,burnminpower,burner min power,uint8 (>=0<=0),%,true,number.boiler_burner_min_power,number.boiler_burnminpower,6,0,1,260,1 -"Topline, GB162",boiler,115,burnmaxpower,burner max power,uint8 (>=0<=254),%,true,number.boiler_burner_max_power,number.boiler_burnmaxpower,6,0,1,261,1 -"Topline, GB162",boiler,115,burnminperiod,burner min period,uint8 (>=0<=120),minutes,true,number.boiler_burner_min_period,number.boiler_burnminperiod,6,0,1,262,1 -"Topline, GB162",boiler,115,absburnpow,burner current power (absolute),uint8,%,false,sensor.boiler_burner_current_power_(absolute),sensor.boiler_absburnpow,6,0,1,263,1 -"Topline, GB162",boiler,115,heatblock,Heatblock temperature,uint16,C,false,sensor.boiler_Heatblock_temperature,sensor.boiler_heatblock,6,0,1/10,264,1 -"Topline, GB162",boiler,115,boilhyston,hysteresis on temperature,int8 (>=-20<=0),C,true,number.boiler_hysteresis_on_temperature,number.boiler_boilhyston,6,0,1,265,1 -"Topline, GB162",boiler,115,boilhystoff,hysteresis off temperature,int8 (>=0<=20),C,true,number.boiler_hysteresis_off_temperature,number.boiler_boilhystoff,6,0,1,266,1 -"Topline, GB162",boiler,115,boil2hyston,hysteresis stage 2 on temperature,int8 (>=-20<=0),C,true,number.boiler_hysteresis_stage_2_on_temperature,number.boiler_boil2hyston,6,0,1,267,1 -"Topline, GB162",boiler,115,boil2hystoff,hysteresis stage 2 off temperature,int8 (>=0<=20),C,true,number.boiler_hysteresis_stage_2_off_temperature,number.boiler_boil2hystoff,6,0,1,268,1 -"Topline, GB162",boiler,115,curveon,heatingcurve on,boolean (>=0<=0), ,true,switch.boiler_heatingcurve_on,switch.boiler_curveon,6,0,1,269,1 -"Topline, GB162",boiler,115,curvebase,heatingcurve base,uint8 (>=20<=90),C,true,number.boiler_heatingcurve_base,number.boiler_curvebase,6,0,1,270,1 -"Topline, GB162",boiler,115,curveend,heatingcurve end,uint8 (>=20<=90),C,true,number.boiler_heatingcurve_end,number.boiler_curveend,6,0,1,271,1 -"Topline, GB162",boiler,115,summertemp,summer temperature,uint8 (>=0<=45),C,true,number.boiler_summer_temperature,number.boiler_summertemp,6,0,1,272,1 -"Topline, GB162",boiler,115,nofrostmode,nofrost mode,boolean (>=0<=0), ,true,switch.boiler_nofrost_mode,switch.boiler_nofrostmode,6,0,1,273,1 -"Topline, GB162",boiler,115,nofrosttemp,nofrost temperature,uint8 (>=0<=10),C,true,number.boiler_nofrost_temperature,number.boiler_nofrosttemp,6,0,1,274,1 +"Topline, GB162",boiler,115,exhausttemp,exhaust temperature,uint16,C,false,sensor.boiler_exhaust_temperature,sensor.boiler_exhausttemp,6,0,1/10,254,1 +"Topline, GB162",boiler,115,burngas,gas,boolean, ,false,binary_sensor.boiler_gas,binary_sensor.boiler_burngas,6,0,1,255,1 +"Topline, GB162",boiler,115,burngas2,gas stage 2,boolean, ,false,binary_sensor.boiler_gas_stage_2,binary_sensor.boiler_burngas2,6,0,1,256,1 +"Topline, GB162",boiler,115,flamecurr,flame current,uint16,µA,false,sensor.boiler_flame_current,sensor.boiler_flamecurr,6,0,1/10,257,1 +"Topline, GB162",boiler,115,fanwork,fan,boolean, ,false,binary_sensor.boiler_fan,binary_sensor.boiler_fanwork,6,0,1,258,1 +"Topline, GB162",boiler,115,ignwork,ignition,boolean, ,false,binary_sensor.boiler_ignition,binary_sensor.boiler_ignwork,6,0,1,259,1 +"Topline, GB162",boiler,115,oilpreheat,oil preheating,boolean, ,false,binary_sensor.boiler_oil_preheating,binary_sensor.boiler_oilpreheat,6,0,1,260,1 +"Topline, GB162",boiler,115,burnminpower,burner min power,uint8 (>=0<=0),%,true,number.boiler_burner_min_power,number.boiler_burnminpower,6,0,1,261,1 +"Topline, GB162",boiler,115,burnmaxpower,burner max power,uint8 (>=0<=254),%,true,number.boiler_burner_max_power,number.boiler_burnmaxpower,6,0,1,262,1 +"Topline, GB162",boiler,115,burnminperiod,burner min period,uint8 (>=0<=120),minutes,true,number.boiler_burner_min_period,number.boiler_burnminperiod,6,0,1,263,1 +"Topline, GB162",boiler,115,absburnpow,burner current power (absolute),uint8,%,false,sensor.boiler_burner_current_power_(absolute),sensor.boiler_absburnpow,6,0,1,264,1 +"Topline, GB162",boiler,115,heatblock,Heatblock temperature,uint16,C,false,sensor.boiler_Heatblock_temperature,sensor.boiler_heatblock,6,0,1/10,265,1 +"Topline, GB162",boiler,115,boilhyston,hysteresis on temperature,int8 (>=-20<=0),C,true,number.boiler_hysteresis_on_temperature,number.boiler_boilhyston,6,0,1,266,1 +"Topline, GB162",boiler,115,boilhystoff,hysteresis off temperature,int8 (>=0<=20),C,true,number.boiler_hysteresis_off_temperature,number.boiler_boilhystoff,6,0,1,267,1 +"Topline, GB162",boiler,115,boil2hyston,hysteresis stage 2 on temperature,int8 (>=-20<=0),C,true,number.boiler_hysteresis_stage_2_on_temperature,number.boiler_boil2hyston,6,0,1,268,1 +"Topline, GB162",boiler,115,boil2hystoff,hysteresis stage 2 off temperature,int8 (>=0<=20),C,true,number.boiler_hysteresis_stage_2_off_temperature,number.boiler_boil2hystoff,6,0,1,269,1 +"Topline, GB162",boiler,115,curveon,heatingcurve on,boolean (>=0<=0), ,true,switch.boiler_heatingcurve_on,switch.boiler_curveon,6,0,1,270,1 +"Topline, GB162",boiler,115,curvebase,heatingcurve base,uint8 (>=20<=90),C,true,number.boiler_heatingcurve_base,number.boiler_curvebase,6,0,1,271,1 +"Topline, GB162",boiler,115,curveend,heatingcurve end,uint8 (>=20<=90),C,true,number.boiler_heatingcurve_end,number.boiler_curveend,6,0,1,272,1 +"Topline, GB162",boiler,115,summertemp,summer temperature,uint8 (>=0<=45),C,true,number.boiler_summer_temperature,number.boiler_summertemp,6,0,1,273,1 +"Topline, GB162",boiler,115,nofrostmode,nofrost mode,boolean (>=0<=0), ,true,switch.boiler_nofrost_mode,switch.boiler_nofrostmode,6,0,1,274,1 +"Topline, GB162",boiler,115,nofrosttemp,nofrost temperature,uint8 (>=0<=10),C,true,number.boiler_nofrost_temperature,number.boiler_nofrosttemp,6,0,1,275,1 "Topline, GB162",boiler,115,heatingactivated,heating activated,boolean (>=0<=0), ,true,switch.boiler_heating_activated,switch.boiler_heatingactivated,6,0,1,14,1 "Topline, GB162",boiler,115,heatingtemp,heating temperature,uint8 (>=0<=90),C,true,number.boiler_heating_temperature,number.boiler_heatingtemp,6,0,1,15,1 "Topline, GB162",boiler,115,heatingpump,heating pump,boolean, ,false,binary_sensor.boiler_heating_pump,binary_sensor.boiler_heatingpump,6,0,1,16,1 @@ -1239,18 +1248,19 @@ device name,device type,product id,shortname,fullname,type [options...] \| (min/ "Topline, GB162",boiler,115,maintenancedate,next maintenance date,string (>=0<=0), ,true,sensor.boiler_next_maintenance_date,sensor.boiler_maintenancedate,6,0,1,72,6 "Topline, GB162",boiler,115,emergencyops,emergency operation,boolean (>=0<=0), ,true,switch.boiler_emergency_operation,switch.boiler_emergencyops,6,0,1,78,1 "Topline, GB162",boiler,115,emergencytemp,emergency temperature,uint8 (>=15<=70),C,true,number.boiler_emergency_temperature,number.boiler_emergencytemp,6,0,1,79,1 -"Topline, GB162",boiler,115,pc0flow,Flow PC0,int16,l/h,false,sensor.boiler_Flow_PC0,sensor.boiler_pc0flow,6,0,1,80,1 -"Topline, GB162",boiler,115,pc1flow,Flow PC1,int16,l/h,false,sensor.boiler_Flow_PC1,sensor.boiler_pc1flow,6,0,1,81,1 -"Topline, GB162",boiler,115,pc1on,PC1,boolean, ,false,binary_sensor.boiler_PC1,binary_sensor.boiler_pc1on,6,0,1,82,1 -"Topline, GB162",boiler,115,pc1rate,PC1 rate,uint8,%,false,sensor.boiler_PC1_rate,sensor.boiler_pc1rate,6,0,1,83,1 -"Topline, GB162",boiler,115,pumpkickhour,pump kick hour,uint8 (>=0<=23),hours,true,number.boiler_pump_kick_hour,number.boiler_pumpkickhour,6,0,1,84,1 -"Topline, GB162",boiler,115,pumpkickday,pump kick day,enum [mo\|tu\|we\|th\|fr\|sa\|su\|all] (>=0<=0), ,true,select.boiler_pump_kick_day,select.boiler_pumpkickday,6,0,1,85,1 -"Topline, GB162",boiler,115,pumpkickdelay,pump kick delay,uint16 (>=0<=32767),minutes,true,number.boiler_pump_kick_delay,number.boiler_pumpkickdelay,6,0,1,86,1 -"Topline, GB162",boiler,115,meterheat,meter heating,uint24,kWh,false,sensor.boiler_meter_heating,sensor.boiler_meterheat,6,0,1/10,100,2 +"Topline, GB162",boiler,115,pc0lpm,Flow PC0,uint16,l/min,false,sensor.boiler_Flow_PC0,sensor.boiler_pc0lpm,6,0,1/10,80,1 +"Topline, GB162",boiler,115,pc0flow,Flow PC0,uint16,l/h,false,sensor.boiler_Flow_PC0,sensor.boiler_pc0flow,6,0,1,81,1 +"Topline, GB162",boiler,115,pc1flow,Flow PC1,uint16,l/h,false,sensor.boiler_Flow_PC1,sensor.boiler_pc1flow,6,0,1,82,1 +"Topline, GB162",boiler,115,pc1on,PC1,boolean, ,false,binary_sensor.boiler_PC1,binary_sensor.boiler_pc1on,6,0,1,83,1 +"Topline, GB162",boiler,115,pc1rate,PC1 rate,uint8,%,false,sensor.boiler_PC1_rate,sensor.boiler_pc1rate,6,0,1,84,1 +"Topline, GB162",boiler,115,pumpkickhour,pump kick hour,uint8 (>=0<=23),hours,true,number.boiler_pump_kick_hour,number.boiler_pumpkickhour,6,0,1,85,1 +"Topline, GB162",boiler,115,pumpkickday,pump kick day,enum [mo\|tu\|we\|th\|fr\|sa\|su\|all] (>=0<=0), ,true,select.boiler_pump_kick_day,select.boiler_pumpkickday,6,0,1,86,1 +"Topline, GB162",boiler,115,pumpkickdelay,pump kick delay,uint16 (>=0<=32767),minutes,true,number.boiler_pump_kick_delay,number.boiler_pumpkickdelay,6,0,1,87,1 +"Topline, GB162",boiler,115,meterheat,meter heating,uint24,kWh,false,sensor.boiler_meter_heating,sensor.boiler_meterheat,6,0,1/10,101,2 "Topline, GB162",boiler,115,dhw.meter,meter,uint24,kWh,false,sensor.boiler_dhw_meter,sensor.boiler_dhw_meter,6,9,1/10,2,2 -"Topline, GB162",boiler,115,gasmeterheat,gas meter heating,uint24,kWh,false,sensor.boiler_gas_meter_heating,sensor.boiler_gasmeterheat,6,0,1/10,275,2 +"Topline, GB162",boiler,115,gasmeterheat,gas meter heating,uint24,kWh,false,sensor.boiler_gas_meter_heating,sensor.boiler_gasmeterheat,6,0,1/10,276,2 "Topline, GB162",boiler,115,dhw.gasmeter,gas meter,uint24,kWh,false,sensor.boiler_dhw_gas_meter,sensor.boiler_dhw_gasmeter,6,9,1/10,71,2 -"Topline, GB162",boiler,115,nrgheat2,energy heating 2,uint24,kWh,false,sensor.boiler_energy_heating_2,sensor.boiler_nrgheat2,6,0,1/10,277,2 +"Topline, GB162",boiler,115,nrgheat2,energy heating 2,uint24,kWh,false,sensor.boiler_energy_heating_2,sensor.boiler_nrgheat2,6,0,1/10,278,2 "Topline, GB162",boiler,115,dhw.nrg2,energy 2,uint24,kWh,false,sensor.boiler_dhw_energy_2,sensor.boiler_dhw_nrg2,6,9,1/10,73,2 "Topline, GB162",boiler,115,dhw.tapactivated,turn on/off,boolean (>=0<=0), ,true,switch.boiler_dhw_turn_on/off,switch.boiler_dhw_tapactivated,6,9,1,28,1 "Topline, GB162",boiler,115,dhw.settemp,set temperature,uint8,C,false,sensor.boiler_dhw_set_temperature,sensor.boiler_dhw_settemp,6,9,1,29,1 @@ -1293,9 +1303,9 @@ device name,device type,product id,shortname,fullname,type [options...] \| (min/ "Topline, GB162",boiler,115,dhw.dhwprio,dhw priority,boolean (>=0<=0), ,true,switch.boiler_dhw_dhw_priority,switch.boiler_dhw_dhwprio,6,9,1,66,1 "Topline, GB162",boiler,115,dhw.starts,starts,uint24, ,false,sensor.boiler_dhw_starts,sensor.boiler_dhw_starts,6,9,1,67,2 "Topline, GB162",boiler,115,dhw.workm,active time,time,minutes,false,sensor.boiler_dhw_active_time,sensor.boiler_dhw_workm,6,9,1,69,2 -"Topline, GB162",boiler,115,nompower,nominal Power,uint8 (>=0<=0),kW,true,number.boiler_nominal_Power,number.boiler_nompower,6,0,1,279,1 -"Topline, GB162",boiler,115,nrgtotal,total energy,uint24,kWh,false,sensor.boiler_total_energy,sensor.boiler_nrgtotal,6,0,1/100,88,2 -"Topline, GB162",boiler,115,nrgheat,energy heating,uint24 (>=0<=10000000),kWh,true,number.boiler_energy_heating,number.boiler_nrgheat,6,0,1/100,90,2 +"Topline, GB162",boiler,115,nompower,nominal Power,uint8 (>=0<=0),kW,true,number.boiler_nominal_Power,number.boiler_nompower,6,0,1,280,1 +"Topline, GB162",boiler,115,nrgtotal,total energy,uint24,kWh,false,sensor.boiler_total_energy,sensor.boiler_nrgtotal,6,0,1/100,89,2 +"Topline, GB162",boiler,115,nrgheat,energy heating,uint24 (>=0<=10000000),kWh,true,number.boiler_energy_heating,number.boiler_nrgheat,6,0,1/100,91,2 "Topline, GB162",boiler,115,dhw.nrg,energy,uint24 (>=0<=10000000),kWh,true,number.boiler_dhw_energy,number.boiler_dhw_nrg,6,9,1/100,0,2 "Cascade MCM10",boiler,121,reset,reset,cmd [-\|maintenance\|error\|history\|message\|hp error\|burner starts\|factory] (>=0<=0), ,true,sensor.boiler_reset,sensor.boiler_reset,6,0,1,0,1 "Cascade MCM10",boiler,121,chimneysweeper,chimney sweeper,cmd [off\|on] (>=0<=0), ,true,sensor.boiler_chimney_sweeper,sensor.boiler_chimneysweeper,6,0,1,1,1 @@ -1311,28 +1321,28 @@ device name,device type,product id,shortname,fullname,type [options...] \| (min/ "Cascade MCM10",boiler,121,syspress,system pressure,uint8,bar,false,sensor.boiler_system_pressure,sensor.boiler_syspress,6,0,1/10,11,1 "Cascade MCM10",boiler,121,boiltemp,actual boiler temperature,uint16,C,false,sensor.boiler_actual_boiler_temperature,sensor.boiler_boiltemp,6,0,1/10,12,1 "Cascade MCM10",boiler,121,headertemp,low loss header,uint16,C,false,sensor.boiler_low_loss_header,sensor.boiler_headertemp,6,0,1/10,13,1 -"Cascade MCM10",boiler,121,exhausttemp,exhaust temperature,uint16,C,false,sensor.boiler_exhaust_temperature,sensor.boiler_exhausttemp,6,0,1/10,253,1 -"Cascade MCM10",boiler,121,burngas,gas,boolean, ,false,binary_sensor.boiler_gas,binary_sensor.boiler_burngas,6,0,1,254,1 -"Cascade MCM10",boiler,121,burngas2,gas stage 2,boolean, ,false,binary_sensor.boiler_gas_stage_2,binary_sensor.boiler_burngas2,6,0,1,255,1 -"Cascade MCM10",boiler,121,flamecurr,flame current,uint16,µA,false,sensor.boiler_flame_current,sensor.boiler_flamecurr,6,0,1/10,256,1 -"Cascade MCM10",boiler,121,fanwork,fan,boolean, ,false,binary_sensor.boiler_fan,binary_sensor.boiler_fanwork,6,0,1,257,1 -"Cascade MCM10",boiler,121,ignwork,ignition,boolean, ,false,binary_sensor.boiler_ignition,binary_sensor.boiler_ignwork,6,0,1,258,1 -"Cascade MCM10",boiler,121,oilpreheat,oil preheating,boolean, ,false,binary_sensor.boiler_oil_preheating,binary_sensor.boiler_oilpreheat,6,0,1,259,1 -"Cascade MCM10",boiler,121,burnminpower,burner min power,uint8 (>=0<=0),%,true,number.boiler_burner_min_power,number.boiler_burnminpower,6,0,1,260,1 -"Cascade MCM10",boiler,121,burnmaxpower,burner max power,uint8 (>=0<=254),%,true,number.boiler_burner_max_power,number.boiler_burnmaxpower,6,0,1,261,1 -"Cascade MCM10",boiler,121,burnminperiod,burner min period,uint8 (>=0<=120),minutes,true,number.boiler_burner_min_period,number.boiler_burnminperiod,6,0,1,262,1 -"Cascade MCM10",boiler,121,absburnpow,burner current power (absolute),uint8,%,false,sensor.boiler_burner_current_power_(absolute),sensor.boiler_absburnpow,6,0,1,263,1 -"Cascade MCM10",boiler,121,heatblock,Heatblock temperature,uint16,C,false,sensor.boiler_Heatblock_temperature,sensor.boiler_heatblock,6,0,1/10,264,1 -"Cascade MCM10",boiler,121,boilhyston,hysteresis on temperature,int8 (>=-20<=0),C,true,number.boiler_hysteresis_on_temperature,number.boiler_boilhyston,6,0,1,265,1 -"Cascade MCM10",boiler,121,boilhystoff,hysteresis off temperature,int8 (>=0<=20),C,true,number.boiler_hysteresis_off_temperature,number.boiler_boilhystoff,6,0,1,266,1 -"Cascade MCM10",boiler,121,boil2hyston,hysteresis stage 2 on temperature,int8 (>=-20<=0),C,true,number.boiler_hysteresis_stage_2_on_temperature,number.boiler_boil2hyston,6,0,1,267,1 -"Cascade MCM10",boiler,121,boil2hystoff,hysteresis stage 2 off temperature,int8 (>=0<=20),C,true,number.boiler_hysteresis_stage_2_off_temperature,number.boiler_boil2hystoff,6,0,1,268,1 -"Cascade MCM10",boiler,121,curveon,heatingcurve on,boolean (>=0<=0), ,true,switch.boiler_heatingcurve_on,switch.boiler_curveon,6,0,1,269,1 -"Cascade MCM10",boiler,121,curvebase,heatingcurve base,uint8 (>=20<=90),C,true,number.boiler_heatingcurve_base,number.boiler_curvebase,6,0,1,270,1 -"Cascade MCM10",boiler,121,curveend,heatingcurve end,uint8 (>=20<=90),C,true,number.boiler_heatingcurve_end,number.boiler_curveend,6,0,1,271,1 -"Cascade MCM10",boiler,121,summertemp,summer temperature,uint8 (>=0<=45),C,true,number.boiler_summer_temperature,number.boiler_summertemp,6,0,1,272,1 -"Cascade MCM10",boiler,121,nofrostmode,nofrost mode,boolean (>=0<=0), ,true,switch.boiler_nofrost_mode,switch.boiler_nofrostmode,6,0,1,273,1 -"Cascade MCM10",boiler,121,nofrosttemp,nofrost temperature,uint8 (>=0<=10),C,true,number.boiler_nofrost_temperature,number.boiler_nofrosttemp,6,0,1,274,1 +"Cascade MCM10",boiler,121,exhausttemp,exhaust temperature,uint16,C,false,sensor.boiler_exhaust_temperature,sensor.boiler_exhausttemp,6,0,1/10,254,1 +"Cascade MCM10",boiler,121,burngas,gas,boolean, ,false,binary_sensor.boiler_gas,binary_sensor.boiler_burngas,6,0,1,255,1 +"Cascade MCM10",boiler,121,burngas2,gas stage 2,boolean, ,false,binary_sensor.boiler_gas_stage_2,binary_sensor.boiler_burngas2,6,0,1,256,1 +"Cascade MCM10",boiler,121,flamecurr,flame current,uint16,µA,false,sensor.boiler_flame_current,sensor.boiler_flamecurr,6,0,1/10,257,1 +"Cascade MCM10",boiler,121,fanwork,fan,boolean, ,false,binary_sensor.boiler_fan,binary_sensor.boiler_fanwork,6,0,1,258,1 +"Cascade MCM10",boiler,121,ignwork,ignition,boolean, ,false,binary_sensor.boiler_ignition,binary_sensor.boiler_ignwork,6,0,1,259,1 +"Cascade MCM10",boiler,121,oilpreheat,oil preheating,boolean, ,false,binary_sensor.boiler_oil_preheating,binary_sensor.boiler_oilpreheat,6,0,1,260,1 +"Cascade MCM10",boiler,121,burnminpower,burner min power,uint8 (>=0<=0),%,true,number.boiler_burner_min_power,number.boiler_burnminpower,6,0,1,261,1 +"Cascade MCM10",boiler,121,burnmaxpower,burner max power,uint8 (>=0<=254),%,true,number.boiler_burner_max_power,number.boiler_burnmaxpower,6,0,1,262,1 +"Cascade MCM10",boiler,121,burnminperiod,burner min period,uint8 (>=0<=120),minutes,true,number.boiler_burner_min_period,number.boiler_burnminperiod,6,0,1,263,1 +"Cascade MCM10",boiler,121,absburnpow,burner current power (absolute),uint8,%,false,sensor.boiler_burner_current_power_(absolute),sensor.boiler_absburnpow,6,0,1,264,1 +"Cascade MCM10",boiler,121,heatblock,Heatblock temperature,uint16,C,false,sensor.boiler_Heatblock_temperature,sensor.boiler_heatblock,6,0,1/10,265,1 +"Cascade MCM10",boiler,121,boilhyston,hysteresis on temperature,int8 (>=-20<=0),C,true,number.boiler_hysteresis_on_temperature,number.boiler_boilhyston,6,0,1,266,1 +"Cascade MCM10",boiler,121,boilhystoff,hysteresis off temperature,int8 (>=0<=20),C,true,number.boiler_hysteresis_off_temperature,number.boiler_boilhystoff,6,0,1,267,1 +"Cascade MCM10",boiler,121,boil2hyston,hysteresis stage 2 on temperature,int8 (>=-20<=0),C,true,number.boiler_hysteresis_stage_2_on_temperature,number.boiler_boil2hyston,6,0,1,268,1 +"Cascade MCM10",boiler,121,boil2hystoff,hysteresis stage 2 off temperature,int8 (>=0<=20),C,true,number.boiler_hysteresis_stage_2_off_temperature,number.boiler_boil2hystoff,6,0,1,269,1 +"Cascade MCM10",boiler,121,curveon,heatingcurve on,boolean (>=0<=0), ,true,switch.boiler_heatingcurve_on,switch.boiler_curveon,6,0,1,270,1 +"Cascade MCM10",boiler,121,curvebase,heatingcurve base,uint8 (>=20<=90),C,true,number.boiler_heatingcurve_base,number.boiler_curvebase,6,0,1,271,1 +"Cascade MCM10",boiler,121,curveend,heatingcurve end,uint8 (>=20<=90),C,true,number.boiler_heatingcurve_end,number.boiler_curveend,6,0,1,272,1 +"Cascade MCM10",boiler,121,summertemp,summer temperature,uint8 (>=0<=45),C,true,number.boiler_summer_temperature,number.boiler_summertemp,6,0,1,273,1 +"Cascade MCM10",boiler,121,nofrostmode,nofrost mode,boolean (>=0<=0), ,true,switch.boiler_nofrost_mode,switch.boiler_nofrostmode,6,0,1,274,1 +"Cascade MCM10",boiler,121,nofrosttemp,nofrost temperature,uint8 (>=0<=10),C,true,number.boiler_nofrost_temperature,number.boiler_nofrosttemp,6,0,1,275,1 "Cascade MCM10",boiler,121,heatingactivated,heating activated,boolean (>=0<=0), ,true,switch.boiler_heating_activated,switch.boiler_heatingactivated,6,0,1,14,1 "Cascade MCM10",boiler,121,heatingtemp,heating temperature,uint8 (>=0<=90),C,true,number.boiler_heating_temperature,number.boiler_heatingtemp,6,0,1,15,1 "Cascade MCM10",boiler,121,heatingpump,heating pump,boolean, ,false,binary_sensor.boiler_heating_pump,binary_sensor.boiler_heatingpump,6,0,1,16,1 @@ -1359,18 +1369,19 @@ device name,device type,product id,shortname,fullname,type [options...] \| (min/ "Cascade MCM10",boiler,121,maintenancedate,next maintenance date,string (>=0<=0), ,true,sensor.boiler_next_maintenance_date,sensor.boiler_maintenancedate,6,0,1,72,6 "Cascade MCM10",boiler,121,emergencyops,emergency operation,boolean (>=0<=0), ,true,switch.boiler_emergency_operation,switch.boiler_emergencyops,6,0,1,78,1 "Cascade MCM10",boiler,121,emergencytemp,emergency temperature,uint8 (>=15<=70),C,true,number.boiler_emergency_temperature,number.boiler_emergencytemp,6,0,1,79,1 -"Cascade MCM10",boiler,121,pc0flow,Flow PC0,int16,l/h,false,sensor.boiler_Flow_PC0,sensor.boiler_pc0flow,6,0,1,80,1 -"Cascade MCM10",boiler,121,pc1flow,Flow PC1,int16,l/h,false,sensor.boiler_Flow_PC1,sensor.boiler_pc1flow,6,0,1,81,1 -"Cascade MCM10",boiler,121,pc1on,PC1,boolean, ,false,binary_sensor.boiler_PC1,binary_sensor.boiler_pc1on,6,0,1,82,1 -"Cascade MCM10",boiler,121,pc1rate,PC1 rate,uint8,%,false,sensor.boiler_PC1_rate,sensor.boiler_pc1rate,6,0,1,83,1 -"Cascade MCM10",boiler,121,pumpkickhour,pump kick hour,uint8 (>=0<=23),hours,true,number.boiler_pump_kick_hour,number.boiler_pumpkickhour,6,0,1,84,1 -"Cascade MCM10",boiler,121,pumpkickday,pump kick day,enum [mo\|tu\|we\|th\|fr\|sa\|su\|all] (>=0<=0), ,true,select.boiler_pump_kick_day,select.boiler_pumpkickday,6,0,1,85,1 -"Cascade MCM10",boiler,121,pumpkickdelay,pump kick delay,uint16 (>=0<=32767),minutes,true,number.boiler_pump_kick_delay,number.boiler_pumpkickdelay,6,0,1,86,1 -"Cascade MCM10",boiler,121,meterheat,meter heating,uint24,kWh,false,sensor.boiler_meter_heating,sensor.boiler_meterheat,6,0,1/10,100,2 +"Cascade MCM10",boiler,121,pc0lpm,Flow PC0,uint16,l/min,false,sensor.boiler_Flow_PC0,sensor.boiler_pc0lpm,6,0,1/10,80,1 +"Cascade MCM10",boiler,121,pc0flow,Flow PC0,uint16,l/h,false,sensor.boiler_Flow_PC0,sensor.boiler_pc0flow,6,0,1,81,1 +"Cascade MCM10",boiler,121,pc1flow,Flow PC1,uint16,l/h,false,sensor.boiler_Flow_PC1,sensor.boiler_pc1flow,6,0,1,82,1 +"Cascade MCM10",boiler,121,pc1on,PC1,boolean, ,false,binary_sensor.boiler_PC1,binary_sensor.boiler_pc1on,6,0,1,83,1 +"Cascade MCM10",boiler,121,pc1rate,PC1 rate,uint8,%,false,sensor.boiler_PC1_rate,sensor.boiler_pc1rate,6,0,1,84,1 +"Cascade MCM10",boiler,121,pumpkickhour,pump kick hour,uint8 (>=0<=23),hours,true,number.boiler_pump_kick_hour,number.boiler_pumpkickhour,6,0,1,85,1 +"Cascade MCM10",boiler,121,pumpkickday,pump kick day,enum [mo\|tu\|we\|th\|fr\|sa\|su\|all] (>=0<=0), ,true,select.boiler_pump_kick_day,select.boiler_pumpkickday,6,0,1,86,1 +"Cascade MCM10",boiler,121,pumpkickdelay,pump kick delay,uint16 (>=0<=32767),minutes,true,number.boiler_pump_kick_delay,number.boiler_pumpkickdelay,6,0,1,87,1 +"Cascade MCM10",boiler,121,meterheat,meter heating,uint24,kWh,false,sensor.boiler_meter_heating,sensor.boiler_meterheat,6,0,1/10,101,2 "Cascade MCM10",boiler,121,dhw.meter,meter,uint24,kWh,false,sensor.boiler_dhw_meter,sensor.boiler_dhw_meter,6,9,1/10,2,2 -"Cascade MCM10",boiler,121,gasmeterheat,gas meter heating,uint24,kWh,false,sensor.boiler_gas_meter_heating,sensor.boiler_gasmeterheat,6,0,1/10,275,2 +"Cascade MCM10",boiler,121,gasmeterheat,gas meter heating,uint24,kWh,false,sensor.boiler_gas_meter_heating,sensor.boiler_gasmeterheat,6,0,1/10,276,2 "Cascade MCM10",boiler,121,dhw.gasmeter,gas meter,uint24,kWh,false,sensor.boiler_dhw_gas_meter,sensor.boiler_dhw_gasmeter,6,9,1/10,71,2 -"Cascade MCM10",boiler,121,nrgheat2,energy heating 2,uint24,kWh,false,sensor.boiler_energy_heating_2,sensor.boiler_nrgheat2,6,0,1/10,277,2 +"Cascade MCM10",boiler,121,nrgheat2,energy heating 2,uint24,kWh,false,sensor.boiler_energy_heating_2,sensor.boiler_nrgheat2,6,0,1/10,278,2 "Cascade MCM10",boiler,121,dhw.nrg2,energy 2,uint24,kWh,false,sensor.boiler_dhw_energy_2,sensor.boiler_dhw_nrg2,6,9,1/10,73,2 "Cascade MCM10",boiler,121,dhw.tapactivated,turn on/off,boolean (>=0<=0), ,true,switch.boiler_dhw_turn_on/off,switch.boiler_dhw_tapactivated,6,9,1,28,1 "Cascade MCM10",boiler,121,dhw.settemp,set temperature,uint8,C,false,sensor.boiler_dhw_set_temperature,sensor.boiler_dhw_settemp,6,9,1,29,1 @@ -1413,9 +1424,9 @@ device name,device type,product id,shortname,fullname,type [options...] \| (min/ "Cascade MCM10",boiler,121,dhw.dhwprio,dhw priority,boolean (>=0<=0), ,true,switch.boiler_dhw_dhw_priority,switch.boiler_dhw_dhwprio,6,9,1,66,1 "Cascade MCM10",boiler,121,dhw.starts,starts,uint24, ,false,sensor.boiler_dhw_starts,sensor.boiler_dhw_starts,6,9,1,67,2 "Cascade MCM10",boiler,121,dhw.workm,active time,time,minutes,false,sensor.boiler_dhw_active_time,sensor.boiler_dhw_workm,6,9,1,69,2 -"Cascade MCM10",boiler,121,nompower,nominal Power,uint8 (>=0<=0),kW,true,number.boiler_nominal_Power,number.boiler_nompower,6,0,1,279,1 -"Cascade MCM10",boiler,121,nrgtotal,total energy,uint24,kWh,false,sensor.boiler_total_energy,sensor.boiler_nrgtotal,6,0,1/100,88,2 -"Cascade MCM10",boiler,121,nrgheat,energy heating,uint24 (>=0<=10000000),kWh,true,number.boiler_energy_heating,number.boiler_nrgheat,6,0,1/100,90,2 +"Cascade MCM10",boiler,121,nompower,nominal Power,uint8 (>=0<=0),kW,true,number.boiler_nominal_Power,number.boiler_nompower,6,0,1,280,1 +"Cascade MCM10",boiler,121,nrgtotal,total energy,uint24,kWh,false,sensor.boiler_total_energy,sensor.boiler_nrgtotal,6,0,1/100,89,2 +"Cascade MCM10",boiler,121,nrgheat,energy heating,uint24 (>=0<=10000000),kWh,true,number.boiler_energy_heating,number.boiler_nrgheat,6,0,1/100,91,2 "Cascade MCM10",boiler,121,dhw.nrg,energy,uint24 (>=0<=10000000),kWh,true,number.boiler_dhw_energy,number.boiler_dhw_nrg,6,9,1/100,0,2 "Proline",boiler,122,reset,reset,cmd [-\|maintenance\|error\|history\|message\|hp error\|burner starts\|factory] (>=0<=0), ,true,sensor.boiler_reset,sensor.boiler_reset,6,0,1,0,1 "Proline",boiler,122,chimneysweeper,chimney sweeper,cmd [off\|on] (>=0<=0), ,true,sensor.boiler_chimney_sweeper,sensor.boiler_chimneysweeper,6,0,1,1,1 @@ -1431,28 +1442,28 @@ device name,device type,product id,shortname,fullname,type [options...] \| (min/ "Proline",boiler,122,syspress,system pressure,uint8,bar,false,sensor.boiler_system_pressure,sensor.boiler_syspress,6,0,1/10,11,1 "Proline",boiler,122,boiltemp,actual boiler temperature,uint16,C,false,sensor.boiler_actual_boiler_temperature,sensor.boiler_boiltemp,6,0,1/10,12,1 "Proline",boiler,122,headertemp,low loss header,uint16,C,false,sensor.boiler_low_loss_header,sensor.boiler_headertemp,6,0,1/10,13,1 -"Proline",boiler,122,exhausttemp,exhaust temperature,uint16,C,false,sensor.boiler_exhaust_temperature,sensor.boiler_exhausttemp,6,0,1/10,253,1 -"Proline",boiler,122,burngas,gas,boolean, ,false,binary_sensor.boiler_gas,binary_sensor.boiler_burngas,6,0,1,254,1 -"Proline",boiler,122,burngas2,gas stage 2,boolean, ,false,binary_sensor.boiler_gas_stage_2,binary_sensor.boiler_burngas2,6,0,1,255,1 -"Proline",boiler,122,flamecurr,flame current,uint16,µA,false,sensor.boiler_flame_current,sensor.boiler_flamecurr,6,0,1/10,256,1 -"Proline",boiler,122,fanwork,fan,boolean, ,false,binary_sensor.boiler_fan,binary_sensor.boiler_fanwork,6,0,1,257,1 -"Proline",boiler,122,ignwork,ignition,boolean, ,false,binary_sensor.boiler_ignition,binary_sensor.boiler_ignwork,6,0,1,258,1 -"Proline",boiler,122,oilpreheat,oil preheating,boolean, ,false,binary_sensor.boiler_oil_preheating,binary_sensor.boiler_oilpreheat,6,0,1,259,1 -"Proline",boiler,122,burnminpower,burner min power,uint8 (>=0<=0),%,true,number.boiler_burner_min_power,number.boiler_burnminpower,6,0,1,260,1 -"Proline",boiler,122,burnmaxpower,burner max power,uint8 (>=0<=254),%,true,number.boiler_burner_max_power,number.boiler_burnmaxpower,6,0,1,261,1 -"Proline",boiler,122,burnminperiod,burner min period,uint8 (>=0<=120),minutes,true,number.boiler_burner_min_period,number.boiler_burnminperiod,6,0,1,262,1 -"Proline",boiler,122,absburnpow,burner current power (absolute),uint8,%,false,sensor.boiler_burner_current_power_(absolute),sensor.boiler_absburnpow,6,0,1,263,1 -"Proline",boiler,122,heatblock,Heatblock temperature,uint16,C,false,sensor.boiler_Heatblock_temperature,sensor.boiler_heatblock,6,0,1/10,264,1 -"Proline",boiler,122,boilhyston,hysteresis on temperature,int8 (>=-20<=0),C,true,number.boiler_hysteresis_on_temperature,number.boiler_boilhyston,6,0,1,265,1 -"Proline",boiler,122,boilhystoff,hysteresis off temperature,int8 (>=0<=20),C,true,number.boiler_hysteresis_off_temperature,number.boiler_boilhystoff,6,0,1,266,1 -"Proline",boiler,122,boil2hyston,hysteresis stage 2 on temperature,int8 (>=-20<=0),C,true,number.boiler_hysteresis_stage_2_on_temperature,number.boiler_boil2hyston,6,0,1,267,1 -"Proline",boiler,122,boil2hystoff,hysteresis stage 2 off temperature,int8 (>=0<=20),C,true,number.boiler_hysteresis_stage_2_off_temperature,number.boiler_boil2hystoff,6,0,1,268,1 -"Proline",boiler,122,curveon,heatingcurve on,boolean (>=0<=0), ,true,switch.boiler_heatingcurve_on,switch.boiler_curveon,6,0,1,269,1 -"Proline",boiler,122,curvebase,heatingcurve base,uint8 (>=20<=90),C,true,number.boiler_heatingcurve_base,number.boiler_curvebase,6,0,1,270,1 -"Proline",boiler,122,curveend,heatingcurve end,uint8 (>=20<=90),C,true,number.boiler_heatingcurve_end,number.boiler_curveend,6,0,1,271,1 -"Proline",boiler,122,summertemp,summer temperature,uint8 (>=0<=45),C,true,number.boiler_summer_temperature,number.boiler_summertemp,6,0,1,272,1 -"Proline",boiler,122,nofrostmode,nofrost mode,boolean (>=0<=0), ,true,switch.boiler_nofrost_mode,switch.boiler_nofrostmode,6,0,1,273,1 -"Proline",boiler,122,nofrosttemp,nofrost temperature,uint8 (>=0<=10),C,true,number.boiler_nofrost_temperature,number.boiler_nofrosttemp,6,0,1,274,1 +"Proline",boiler,122,exhausttemp,exhaust temperature,uint16,C,false,sensor.boiler_exhaust_temperature,sensor.boiler_exhausttemp,6,0,1/10,254,1 +"Proline",boiler,122,burngas,gas,boolean, ,false,binary_sensor.boiler_gas,binary_sensor.boiler_burngas,6,0,1,255,1 +"Proline",boiler,122,burngas2,gas stage 2,boolean, ,false,binary_sensor.boiler_gas_stage_2,binary_sensor.boiler_burngas2,6,0,1,256,1 +"Proline",boiler,122,flamecurr,flame current,uint16,µA,false,sensor.boiler_flame_current,sensor.boiler_flamecurr,6,0,1/10,257,1 +"Proline",boiler,122,fanwork,fan,boolean, ,false,binary_sensor.boiler_fan,binary_sensor.boiler_fanwork,6,0,1,258,1 +"Proline",boiler,122,ignwork,ignition,boolean, ,false,binary_sensor.boiler_ignition,binary_sensor.boiler_ignwork,6,0,1,259,1 +"Proline",boiler,122,oilpreheat,oil preheating,boolean, ,false,binary_sensor.boiler_oil_preheating,binary_sensor.boiler_oilpreheat,6,0,1,260,1 +"Proline",boiler,122,burnminpower,burner min power,uint8 (>=0<=0),%,true,number.boiler_burner_min_power,number.boiler_burnminpower,6,0,1,261,1 +"Proline",boiler,122,burnmaxpower,burner max power,uint8 (>=0<=254),%,true,number.boiler_burner_max_power,number.boiler_burnmaxpower,6,0,1,262,1 +"Proline",boiler,122,burnminperiod,burner min period,uint8 (>=0<=120),minutes,true,number.boiler_burner_min_period,number.boiler_burnminperiod,6,0,1,263,1 +"Proline",boiler,122,absburnpow,burner current power (absolute),uint8,%,false,sensor.boiler_burner_current_power_(absolute),sensor.boiler_absburnpow,6,0,1,264,1 +"Proline",boiler,122,heatblock,Heatblock temperature,uint16,C,false,sensor.boiler_Heatblock_temperature,sensor.boiler_heatblock,6,0,1/10,265,1 +"Proline",boiler,122,boilhyston,hysteresis on temperature,int8 (>=-20<=0),C,true,number.boiler_hysteresis_on_temperature,number.boiler_boilhyston,6,0,1,266,1 +"Proline",boiler,122,boilhystoff,hysteresis off temperature,int8 (>=0<=20),C,true,number.boiler_hysteresis_off_temperature,number.boiler_boilhystoff,6,0,1,267,1 +"Proline",boiler,122,boil2hyston,hysteresis stage 2 on temperature,int8 (>=-20<=0),C,true,number.boiler_hysteresis_stage_2_on_temperature,number.boiler_boil2hyston,6,0,1,268,1 +"Proline",boiler,122,boil2hystoff,hysteresis stage 2 off temperature,int8 (>=0<=20),C,true,number.boiler_hysteresis_stage_2_off_temperature,number.boiler_boil2hystoff,6,0,1,269,1 +"Proline",boiler,122,curveon,heatingcurve on,boolean (>=0<=0), ,true,switch.boiler_heatingcurve_on,switch.boiler_curveon,6,0,1,270,1 +"Proline",boiler,122,curvebase,heatingcurve base,uint8 (>=20<=90),C,true,number.boiler_heatingcurve_base,number.boiler_curvebase,6,0,1,271,1 +"Proline",boiler,122,curveend,heatingcurve end,uint8 (>=20<=90),C,true,number.boiler_heatingcurve_end,number.boiler_curveend,6,0,1,272,1 +"Proline",boiler,122,summertemp,summer temperature,uint8 (>=0<=45),C,true,number.boiler_summer_temperature,number.boiler_summertemp,6,0,1,273,1 +"Proline",boiler,122,nofrostmode,nofrost mode,boolean (>=0<=0), ,true,switch.boiler_nofrost_mode,switch.boiler_nofrostmode,6,0,1,274,1 +"Proline",boiler,122,nofrosttemp,nofrost temperature,uint8 (>=0<=10),C,true,number.boiler_nofrost_temperature,number.boiler_nofrosttemp,6,0,1,275,1 "Proline",boiler,122,heatingactivated,heating activated,boolean (>=0<=0), ,true,switch.boiler_heating_activated,switch.boiler_heatingactivated,6,0,1,14,1 "Proline",boiler,122,heatingtemp,heating temperature,uint8 (>=0<=90),C,true,number.boiler_heating_temperature,number.boiler_heatingtemp,6,0,1,15,1 "Proline",boiler,122,heatingpump,heating pump,boolean, ,false,binary_sensor.boiler_heating_pump,binary_sensor.boiler_heatingpump,6,0,1,16,1 @@ -1479,18 +1490,19 @@ device name,device type,product id,shortname,fullname,type [options...] \| (min/ "Proline",boiler,122,maintenancedate,next maintenance date,string (>=0<=0), ,true,sensor.boiler_next_maintenance_date,sensor.boiler_maintenancedate,6,0,1,72,6 "Proline",boiler,122,emergencyops,emergency operation,boolean (>=0<=0), ,true,switch.boiler_emergency_operation,switch.boiler_emergencyops,6,0,1,78,1 "Proline",boiler,122,emergencytemp,emergency temperature,uint8 (>=15<=70),C,true,number.boiler_emergency_temperature,number.boiler_emergencytemp,6,0,1,79,1 -"Proline",boiler,122,pc0flow,Flow PC0,int16,l/h,false,sensor.boiler_Flow_PC0,sensor.boiler_pc0flow,6,0,1,80,1 -"Proline",boiler,122,pc1flow,Flow PC1,int16,l/h,false,sensor.boiler_Flow_PC1,sensor.boiler_pc1flow,6,0,1,81,1 -"Proline",boiler,122,pc1on,PC1,boolean, ,false,binary_sensor.boiler_PC1,binary_sensor.boiler_pc1on,6,0,1,82,1 -"Proline",boiler,122,pc1rate,PC1 rate,uint8,%,false,sensor.boiler_PC1_rate,sensor.boiler_pc1rate,6,0,1,83,1 -"Proline",boiler,122,pumpkickhour,pump kick hour,uint8 (>=0<=23),hours,true,number.boiler_pump_kick_hour,number.boiler_pumpkickhour,6,0,1,84,1 -"Proline",boiler,122,pumpkickday,pump kick day,enum [mo\|tu\|we\|th\|fr\|sa\|su\|all] (>=0<=0), ,true,select.boiler_pump_kick_day,select.boiler_pumpkickday,6,0,1,85,1 -"Proline",boiler,122,pumpkickdelay,pump kick delay,uint16 (>=0<=32767),minutes,true,number.boiler_pump_kick_delay,number.boiler_pumpkickdelay,6,0,1,86,1 -"Proline",boiler,122,meterheat,meter heating,uint24,kWh,false,sensor.boiler_meter_heating,sensor.boiler_meterheat,6,0,1/10,100,2 +"Proline",boiler,122,pc0lpm,Flow PC0,uint16,l/min,false,sensor.boiler_Flow_PC0,sensor.boiler_pc0lpm,6,0,1/10,80,1 +"Proline",boiler,122,pc0flow,Flow PC0,uint16,l/h,false,sensor.boiler_Flow_PC0,sensor.boiler_pc0flow,6,0,1,81,1 +"Proline",boiler,122,pc1flow,Flow PC1,uint16,l/h,false,sensor.boiler_Flow_PC1,sensor.boiler_pc1flow,6,0,1,82,1 +"Proline",boiler,122,pc1on,PC1,boolean, ,false,binary_sensor.boiler_PC1,binary_sensor.boiler_pc1on,6,0,1,83,1 +"Proline",boiler,122,pc1rate,PC1 rate,uint8,%,false,sensor.boiler_PC1_rate,sensor.boiler_pc1rate,6,0,1,84,1 +"Proline",boiler,122,pumpkickhour,pump kick hour,uint8 (>=0<=23),hours,true,number.boiler_pump_kick_hour,number.boiler_pumpkickhour,6,0,1,85,1 +"Proline",boiler,122,pumpkickday,pump kick day,enum [mo\|tu\|we\|th\|fr\|sa\|su\|all] (>=0<=0), ,true,select.boiler_pump_kick_day,select.boiler_pumpkickday,6,0,1,86,1 +"Proline",boiler,122,pumpkickdelay,pump kick delay,uint16 (>=0<=32767),minutes,true,number.boiler_pump_kick_delay,number.boiler_pumpkickdelay,6,0,1,87,1 +"Proline",boiler,122,meterheat,meter heating,uint24,kWh,false,sensor.boiler_meter_heating,sensor.boiler_meterheat,6,0,1/10,101,2 "Proline",boiler,122,dhw.meter,meter,uint24,kWh,false,sensor.boiler_dhw_meter,sensor.boiler_dhw_meter,6,9,1/10,2,2 -"Proline",boiler,122,gasmeterheat,gas meter heating,uint24,kWh,false,sensor.boiler_gas_meter_heating,sensor.boiler_gasmeterheat,6,0,1/10,275,2 +"Proline",boiler,122,gasmeterheat,gas meter heating,uint24,kWh,false,sensor.boiler_gas_meter_heating,sensor.boiler_gasmeterheat,6,0,1/10,276,2 "Proline",boiler,122,dhw.gasmeter,gas meter,uint24,kWh,false,sensor.boiler_dhw_gas_meter,sensor.boiler_dhw_gasmeter,6,9,1/10,71,2 -"Proline",boiler,122,nrgheat2,energy heating 2,uint24,kWh,false,sensor.boiler_energy_heating_2,sensor.boiler_nrgheat2,6,0,1/10,277,2 +"Proline",boiler,122,nrgheat2,energy heating 2,uint24,kWh,false,sensor.boiler_energy_heating_2,sensor.boiler_nrgheat2,6,0,1/10,278,2 "Proline",boiler,122,dhw.nrg2,energy 2,uint24,kWh,false,sensor.boiler_dhw_energy_2,sensor.boiler_dhw_nrg2,6,9,1/10,73,2 "Proline",boiler,122,dhw.tapactivated,turn on/off,boolean (>=0<=0), ,true,switch.boiler_dhw_turn_on/off,switch.boiler_dhw_tapactivated,6,9,1,28,1 "Proline",boiler,122,dhw.settemp,set temperature,uint8,C,false,sensor.boiler_dhw_set_temperature,sensor.boiler_dhw_settemp,6,9,1,29,1 @@ -1533,9 +1545,9 @@ device name,device type,product id,shortname,fullname,type [options...] \| (min/ "Proline",boiler,122,dhw.dhwprio,dhw priority,boolean (>=0<=0), ,true,switch.boiler_dhw_dhw_priority,switch.boiler_dhw_dhwprio,6,9,1,66,1 "Proline",boiler,122,dhw.starts,starts,uint24, ,false,sensor.boiler_dhw_starts,sensor.boiler_dhw_starts,6,9,1,67,2 "Proline",boiler,122,dhw.workm,active time,time,minutes,false,sensor.boiler_dhw_active_time,sensor.boiler_dhw_workm,6,9,1,69,2 -"Proline",boiler,122,nompower,nominal Power,uint8 (>=0<=0),kW,true,number.boiler_nominal_Power,number.boiler_nompower,6,0,1,279,1 -"Proline",boiler,122,nrgtotal,total energy,uint24,kWh,false,sensor.boiler_total_energy,sensor.boiler_nrgtotal,6,0,1/100,88,2 -"Proline",boiler,122,nrgheat,energy heating,uint24 (>=0<=10000000),kWh,true,number.boiler_energy_heating,number.boiler_nrgheat,6,0,1/100,90,2 +"Proline",boiler,122,nompower,nominal Power,uint8 (>=0<=0),kW,true,number.boiler_nominal_Power,number.boiler_nompower,6,0,1,280,1 +"Proline",boiler,122,nrgtotal,total energy,uint24,kWh,false,sensor.boiler_total_energy,sensor.boiler_nrgtotal,6,0,1/100,89,2 +"Proline",boiler,122,nrgheat,energy heating,uint24 (>=0<=10000000),kWh,true,number.boiler_energy_heating,number.boiler_nrgheat,6,0,1/100,91,2 "Proline",boiler,122,dhw.nrg,energy,uint24 (>=0<=10000000),kWh,true,number.boiler_dhw_energy,number.boiler_dhw_nrg,6,9,1/100,0,2 "GB*72, Trendline, Cerapur, Greenstar Si",boiler,123,reset,reset,cmd [-\|maintenance\|error\|history\|message\|hp error\|burner starts\|factory] (>=0<=0), ,true,sensor.boiler_reset,sensor.boiler_reset,6,0,1,0,1 "GB*72, Trendline, Cerapur, Greenstar Si",boiler,123,chimneysweeper,chimney sweeper,cmd [off\|on] (>=0<=0), ,true,sensor.boiler_chimney_sweeper,sensor.boiler_chimneysweeper,6,0,1,1,1 @@ -1551,28 +1563,28 @@ device name,device type,product id,shortname,fullname,type [options...] \| (min/ "GB*72, Trendline, Cerapur, Greenstar Si",boiler,123,syspress,system pressure,uint8,bar,false,sensor.boiler_system_pressure,sensor.boiler_syspress,6,0,1/10,11,1 "GB*72, Trendline, Cerapur, Greenstar Si",boiler,123,boiltemp,actual boiler temperature,uint16,C,false,sensor.boiler_actual_boiler_temperature,sensor.boiler_boiltemp,6,0,1/10,12,1 "GB*72, Trendline, Cerapur, Greenstar Si",boiler,123,headertemp,low loss header,uint16,C,false,sensor.boiler_low_loss_header,sensor.boiler_headertemp,6,0,1/10,13,1 -"GB*72, Trendline, Cerapur, Greenstar Si",boiler,123,exhausttemp,exhaust temperature,uint16,C,false,sensor.boiler_exhaust_temperature,sensor.boiler_exhausttemp,6,0,1/10,253,1 -"GB*72, Trendline, Cerapur, Greenstar Si",boiler,123,burngas,gas,boolean, ,false,binary_sensor.boiler_gas,binary_sensor.boiler_burngas,6,0,1,254,1 -"GB*72, Trendline, Cerapur, Greenstar Si",boiler,123,burngas2,gas stage 2,boolean, ,false,binary_sensor.boiler_gas_stage_2,binary_sensor.boiler_burngas2,6,0,1,255,1 -"GB*72, Trendline, Cerapur, Greenstar Si",boiler,123,flamecurr,flame current,uint16,µA,false,sensor.boiler_flame_current,sensor.boiler_flamecurr,6,0,1/10,256,1 -"GB*72, Trendline, Cerapur, Greenstar Si",boiler,123,fanwork,fan,boolean, ,false,binary_sensor.boiler_fan,binary_sensor.boiler_fanwork,6,0,1,257,1 -"GB*72, Trendline, Cerapur, Greenstar Si",boiler,123,ignwork,ignition,boolean, ,false,binary_sensor.boiler_ignition,binary_sensor.boiler_ignwork,6,0,1,258,1 -"GB*72, Trendline, Cerapur, Greenstar Si",boiler,123,oilpreheat,oil preheating,boolean, ,false,binary_sensor.boiler_oil_preheating,binary_sensor.boiler_oilpreheat,6,0,1,259,1 -"GB*72, Trendline, Cerapur, Greenstar Si",boiler,123,burnminpower,burner min power,uint8 (>=0<=0),%,true,number.boiler_burner_min_power,number.boiler_burnminpower,6,0,1,260,1 -"GB*72, Trendline, Cerapur, Greenstar Si",boiler,123,burnmaxpower,burner max power,uint8 (>=0<=254),%,true,number.boiler_burner_max_power,number.boiler_burnmaxpower,6,0,1,261,1 -"GB*72, Trendline, Cerapur, Greenstar Si",boiler,123,burnminperiod,burner min period,uint8 (>=0<=120),minutes,true,number.boiler_burner_min_period,number.boiler_burnminperiod,6,0,1,262,1 -"GB*72, Trendline, Cerapur, Greenstar Si",boiler,123,absburnpow,burner current power (absolute),uint8,%,false,sensor.boiler_burner_current_power_(absolute),sensor.boiler_absburnpow,6,0,1,263,1 -"GB*72, Trendline, Cerapur, Greenstar Si",boiler,123,heatblock,Heatblock temperature,uint16,C,false,sensor.boiler_Heatblock_temperature,sensor.boiler_heatblock,6,0,1/10,264,1 -"GB*72, Trendline, Cerapur, Greenstar Si",boiler,123,boilhyston,hysteresis on temperature,int8 (>=-20<=0),C,true,number.boiler_hysteresis_on_temperature,number.boiler_boilhyston,6,0,1,265,1 -"GB*72, Trendline, Cerapur, Greenstar Si",boiler,123,boilhystoff,hysteresis off temperature,int8 (>=0<=20),C,true,number.boiler_hysteresis_off_temperature,number.boiler_boilhystoff,6,0,1,266,1 -"GB*72, Trendline, Cerapur, Greenstar Si",boiler,123,boil2hyston,hysteresis stage 2 on temperature,int8 (>=-20<=0),C,true,number.boiler_hysteresis_stage_2_on_temperature,number.boiler_boil2hyston,6,0,1,267,1 -"GB*72, Trendline, Cerapur, Greenstar Si",boiler,123,boil2hystoff,hysteresis stage 2 off temperature,int8 (>=0<=20),C,true,number.boiler_hysteresis_stage_2_off_temperature,number.boiler_boil2hystoff,6,0,1,268,1 -"GB*72, Trendline, Cerapur, Greenstar Si",boiler,123,curveon,heatingcurve on,boolean (>=0<=0), ,true,switch.boiler_heatingcurve_on,switch.boiler_curveon,6,0,1,269,1 -"GB*72, Trendline, Cerapur, Greenstar Si",boiler,123,curvebase,heatingcurve base,uint8 (>=20<=90),C,true,number.boiler_heatingcurve_base,number.boiler_curvebase,6,0,1,270,1 -"GB*72, Trendline, Cerapur, Greenstar Si",boiler,123,curveend,heatingcurve end,uint8 (>=20<=90),C,true,number.boiler_heatingcurve_end,number.boiler_curveend,6,0,1,271,1 -"GB*72, Trendline, Cerapur, Greenstar Si",boiler,123,summertemp,summer temperature,uint8 (>=0<=45),C,true,number.boiler_summer_temperature,number.boiler_summertemp,6,0,1,272,1 -"GB*72, Trendline, Cerapur, Greenstar Si",boiler,123,nofrostmode,nofrost mode,boolean (>=0<=0), ,true,switch.boiler_nofrost_mode,switch.boiler_nofrostmode,6,0,1,273,1 -"GB*72, Trendline, Cerapur, Greenstar Si",boiler,123,nofrosttemp,nofrost temperature,uint8 (>=0<=10),C,true,number.boiler_nofrost_temperature,number.boiler_nofrosttemp,6,0,1,274,1 +"GB*72, Trendline, Cerapur, Greenstar Si",boiler,123,exhausttemp,exhaust temperature,uint16,C,false,sensor.boiler_exhaust_temperature,sensor.boiler_exhausttemp,6,0,1/10,254,1 +"GB*72, Trendline, Cerapur, Greenstar Si",boiler,123,burngas,gas,boolean, ,false,binary_sensor.boiler_gas,binary_sensor.boiler_burngas,6,0,1,255,1 +"GB*72, Trendline, Cerapur, Greenstar Si",boiler,123,burngas2,gas stage 2,boolean, ,false,binary_sensor.boiler_gas_stage_2,binary_sensor.boiler_burngas2,6,0,1,256,1 +"GB*72, Trendline, Cerapur, Greenstar Si",boiler,123,flamecurr,flame current,uint16,µA,false,sensor.boiler_flame_current,sensor.boiler_flamecurr,6,0,1/10,257,1 +"GB*72, Trendline, Cerapur, Greenstar Si",boiler,123,fanwork,fan,boolean, ,false,binary_sensor.boiler_fan,binary_sensor.boiler_fanwork,6,0,1,258,1 +"GB*72, Trendline, Cerapur, Greenstar Si",boiler,123,ignwork,ignition,boolean, ,false,binary_sensor.boiler_ignition,binary_sensor.boiler_ignwork,6,0,1,259,1 +"GB*72, Trendline, Cerapur, Greenstar Si",boiler,123,oilpreheat,oil preheating,boolean, ,false,binary_sensor.boiler_oil_preheating,binary_sensor.boiler_oilpreheat,6,0,1,260,1 +"GB*72, Trendline, Cerapur, Greenstar Si",boiler,123,burnminpower,burner min power,uint8 (>=0<=0),%,true,number.boiler_burner_min_power,number.boiler_burnminpower,6,0,1,261,1 +"GB*72, Trendline, Cerapur, Greenstar Si",boiler,123,burnmaxpower,burner max power,uint8 (>=0<=254),%,true,number.boiler_burner_max_power,number.boiler_burnmaxpower,6,0,1,262,1 +"GB*72, Trendline, Cerapur, Greenstar Si",boiler,123,burnminperiod,burner min period,uint8 (>=0<=120),minutes,true,number.boiler_burner_min_period,number.boiler_burnminperiod,6,0,1,263,1 +"GB*72, Trendline, Cerapur, Greenstar Si",boiler,123,absburnpow,burner current power (absolute),uint8,%,false,sensor.boiler_burner_current_power_(absolute),sensor.boiler_absburnpow,6,0,1,264,1 +"GB*72, Trendline, Cerapur, Greenstar Si",boiler,123,heatblock,Heatblock temperature,uint16,C,false,sensor.boiler_Heatblock_temperature,sensor.boiler_heatblock,6,0,1/10,265,1 +"GB*72, Trendline, Cerapur, Greenstar Si",boiler,123,boilhyston,hysteresis on temperature,int8 (>=-20<=0),C,true,number.boiler_hysteresis_on_temperature,number.boiler_boilhyston,6,0,1,266,1 +"GB*72, Trendline, Cerapur, Greenstar Si",boiler,123,boilhystoff,hysteresis off temperature,int8 (>=0<=20),C,true,number.boiler_hysteresis_off_temperature,number.boiler_boilhystoff,6,0,1,267,1 +"GB*72, Trendline, Cerapur, Greenstar Si",boiler,123,boil2hyston,hysteresis stage 2 on temperature,int8 (>=-20<=0),C,true,number.boiler_hysteresis_stage_2_on_temperature,number.boiler_boil2hyston,6,0,1,268,1 +"GB*72, Trendline, Cerapur, Greenstar Si",boiler,123,boil2hystoff,hysteresis stage 2 off temperature,int8 (>=0<=20),C,true,number.boiler_hysteresis_stage_2_off_temperature,number.boiler_boil2hystoff,6,0,1,269,1 +"GB*72, Trendline, Cerapur, Greenstar Si",boiler,123,curveon,heatingcurve on,boolean (>=0<=0), ,true,switch.boiler_heatingcurve_on,switch.boiler_curveon,6,0,1,270,1 +"GB*72, Trendline, Cerapur, Greenstar Si",boiler,123,curvebase,heatingcurve base,uint8 (>=20<=90),C,true,number.boiler_heatingcurve_base,number.boiler_curvebase,6,0,1,271,1 +"GB*72, Trendline, Cerapur, Greenstar Si",boiler,123,curveend,heatingcurve end,uint8 (>=20<=90),C,true,number.boiler_heatingcurve_end,number.boiler_curveend,6,0,1,272,1 +"GB*72, Trendline, Cerapur, Greenstar Si",boiler,123,summertemp,summer temperature,uint8 (>=0<=45),C,true,number.boiler_summer_temperature,number.boiler_summertemp,6,0,1,273,1 +"GB*72, Trendline, Cerapur, Greenstar Si",boiler,123,nofrostmode,nofrost mode,boolean (>=0<=0), ,true,switch.boiler_nofrost_mode,switch.boiler_nofrostmode,6,0,1,274,1 +"GB*72, Trendline, Cerapur, Greenstar Si",boiler,123,nofrosttemp,nofrost temperature,uint8 (>=0<=10),C,true,number.boiler_nofrost_temperature,number.boiler_nofrosttemp,6,0,1,275,1 "GB*72, Trendline, Cerapur, Greenstar Si",boiler,123,heatingactivated,heating activated,boolean (>=0<=0), ,true,switch.boiler_heating_activated,switch.boiler_heatingactivated,6,0,1,14,1 "GB*72, Trendline, Cerapur, Greenstar Si",boiler,123,heatingtemp,heating temperature,uint8 (>=0<=90),C,true,number.boiler_heating_temperature,number.boiler_heatingtemp,6,0,1,15,1 "GB*72, Trendline, Cerapur, Greenstar Si",boiler,123,heatingpump,heating pump,boolean, ,false,binary_sensor.boiler_heating_pump,binary_sensor.boiler_heatingpump,6,0,1,16,1 @@ -1599,18 +1611,19 @@ device name,device type,product id,shortname,fullname,type [options...] \| (min/ "GB*72, Trendline, Cerapur, Greenstar Si",boiler,123,maintenancedate,next maintenance date,string (>=0<=0), ,true,sensor.boiler_next_maintenance_date,sensor.boiler_maintenancedate,6,0,1,72,6 "GB*72, Trendline, Cerapur, Greenstar Si",boiler,123,emergencyops,emergency operation,boolean (>=0<=0), ,true,switch.boiler_emergency_operation,switch.boiler_emergencyops,6,0,1,78,1 "GB*72, Trendline, Cerapur, Greenstar Si",boiler,123,emergencytemp,emergency temperature,uint8 (>=15<=70),C,true,number.boiler_emergency_temperature,number.boiler_emergencytemp,6,0,1,79,1 -"GB*72, Trendline, Cerapur, Greenstar Si",boiler,123,pc0flow,Flow PC0,int16,l/h,false,sensor.boiler_Flow_PC0,sensor.boiler_pc0flow,6,0,1,80,1 -"GB*72, Trendline, Cerapur, Greenstar Si",boiler,123,pc1flow,Flow PC1,int16,l/h,false,sensor.boiler_Flow_PC1,sensor.boiler_pc1flow,6,0,1,81,1 -"GB*72, Trendline, Cerapur, Greenstar Si",boiler,123,pc1on,PC1,boolean, ,false,binary_sensor.boiler_PC1,binary_sensor.boiler_pc1on,6,0,1,82,1 -"GB*72, Trendline, Cerapur, Greenstar Si",boiler,123,pc1rate,PC1 rate,uint8,%,false,sensor.boiler_PC1_rate,sensor.boiler_pc1rate,6,0,1,83,1 -"GB*72, Trendline, Cerapur, Greenstar Si",boiler,123,pumpkickhour,pump kick hour,uint8 (>=0<=23),hours,true,number.boiler_pump_kick_hour,number.boiler_pumpkickhour,6,0,1,84,1 -"GB*72, Trendline, Cerapur, Greenstar Si",boiler,123,pumpkickday,pump kick day,enum [mo\|tu\|we\|th\|fr\|sa\|su\|all] (>=0<=0), ,true,select.boiler_pump_kick_day,select.boiler_pumpkickday,6,0,1,85,1 -"GB*72, Trendline, Cerapur, Greenstar Si",boiler,123,pumpkickdelay,pump kick delay,uint16 (>=0<=32767),minutes,true,number.boiler_pump_kick_delay,number.boiler_pumpkickdelay,6,0,1,86,1 -"GB*72, Trendline, Cerapur, Greenstar Si",boiler,123,meterheat,meter heating,uint24,kWh,false,sensor.boiler_meter_heating,sensor.boiler_meterheat,6,0,1/10,100,2 +"GB*72, Trendline, Cerapur, Greenstar Si",boiler,123,pc0lpm,Flow PC0,uint16,l/min,false,sensor.boiler_Flow_PC0,sensor.boiler_pc0lpm,6,0,1/10,80,1 +"GB*72, Trendline, Cerapur, Greenstar Si",boiler,123,pc0flow,Flow PC0,uint16,l/h,false,sensor.boiler_Flow_PC0,sensor.boiler_pc0flow,6,0,1,81,1 +"GB*72, Trendline, Cerapur, Greenstar Si",boiler,123,pc1flow,Flow PC1,uint16,l/h,false,sensor.boiler_Flow_PC1,sensor.boiler_pc1flow,6,0,1,82,1 +"GB*72, Trendline, Cerapur, Greenstar Si",boiler,123,pc1on,PC1,boolean, ,false,binary_sensor.boiler_PC1,binary_sensor.boiler_pc1on,6,0,1,83,1 +"GB*72, Trendline, Cerapur, Greenstar Si",boiler,123,pc1rate,PC1 rate,uint8,%,false,sensor.boiler_PC1_rate,sensor.boiler_pc1rate,6,0,1,84,1 +"GB*72, Trendline, Cerapur, Greenstar Si",boiler,123,pumpkickhour,pump kick hour,uint8 (>=0<=23),hours,true,number.boiler_pump_kick_hour,number.boiler_pumpkickhour,6,0,1,85,1 +"GB*72, Trendline, Cerapur, Greenstar Si",boiler,123,pumpkickday,pump kick day,enum [mo\|tu\|we\|th\|fr\|sa\|su\|all] (>=0<=0), ,true,select.boiler_pump_kick_day,select.boiler_pumpkickday,6,0,1,86,1 +"GB*72, Trendline, Cerapur, Greenstar Si",boiler,123,pumpkickdelay,pump kick delay,uint16 (>=0<=32767),minutes,true,number.boiler_pump_kick_delay,number.boiler_pumpkickdelay,6,0,1,87,1 +"GB*72, Trendline, Cerapur, Greenstar Si",boiler,123,meterheat,meter heating,uint24,kWh,false,sensor.boiler_meter_heating,sensor.boiler_meterheat,6,0,1/10,101,2 "GB*72, Trendline, Cerapur, Greenstar Si",boiler,123,dhw.meter,meter,uint24,kWh,false,sensor.boiler_dhw_meter,sensor.boiler_dhw_meter,6,9,1/10,2,2 -"GB*72, Trendline, Cerapur, Greenstar Si",boiler,123,gasmeterheat,gas meter heating,uint24,kWh,false,sensor.boiler_gas_meter_heating,sensor.boiler_gasmeterheat,6,0,1/10,275,2 +"GB*72, Trendline, Cerapur, Greenstar Si",boiler,123,gasmeterheat,gas meter heating,uint24,kWh,false,sensor.boiler_gas_meter_heating,sensor.boiler_gasmeterheat,6,0,1/10,276,2 "GB*72, Trendline, Cerapur, Greenstar Si",boiler,123,dhw.gasmeter,gas meter,uint24,kWh,false,sensor.boiler_dhw_gas_meter,sensor.boiler_dhw_gasmeter,6,9,1/10,71,2 -"GB*72, Trendline, Cerapur, Greenstar Si",boiler,123,nrgheat2,energy heating 2,uint24,kWh,false,sensor.boiler_energy_heating_2,sensor.boiler_nrgheat2,6,0,1/10,277,2 +"GB*72, Trendline, Cerapur, Greenstar Si",boiler,123,nrgheat2,energy heating 2,uint24,kWh,false,sensor.boiler_energy_heating_2,sensor.boiler_nrgheat2,6,0,1/10,278,2 "GB*72, Trendline, Cerapur, Greenstar Si",boiler,123,dhw.nrg2,energy 2,uint24,kWh,false,sensor.boiler_dhw_energy_2,sensor.boiler_dhw_nrg2,6,9,1/10,73,2 "GB*72, Trendline, Cerapur, Greenstar Si",boiler,123,dhw.tapactivated,turn on/off,boolean (>=0<=0), ,true,switch.boiler_dhw_turn_on/off,switch.boiler_dhw_tapactivated,6,9,1,28,1 "GB*72, Trendline, Cerapur, Greenstar Si",boiler,123,dhw.settemp,set temperature,uint8,C,false,sensor.boiler_dhw_set_temperature,sensor.boiler_dhw_settemp,6,9,1,29,1 @@ -1653,9 +1666,9 @@ device name,device type,product id,shortname,fullname,type [options...] \| (min/ "GB*72, Trendline, Cerapur, Greenstar Si",boiler,123,dhw.dhwprio,dhw priority,boolean (>=0<=0), ,true,switch.boiler_dhw_dhw_priority,switch.boiler_dhw_dhwprio,6,9,1,66,1 "GB*72, Trendline, Cerapur, Greenstar Si",boiler,123,dhw.starts,starts,uint24, ,false,sensor.boiler_dhw_starts,sensor.boiler_dhw_starts,6,9,1,67,2 "GB*72, Trendline, Cerapur, Greenstar Si",boiler,123,dhw.workm,active time,time,minutes,false,sensor.boiler_dhw_active_time,sensor.boiler_dhw_workm,6,9,1,69,2 -"GB*72, Trendline, Cerapur, Greenstar Si",boiler,123,nompower,nominal Power,uint8 (>=0<=0),kW,true,number.boiler_nominal_Power,number.boiler_nompower,6,0,1,279,1 -"GB*72, Trendline, Cerapur, Greenstar Si",boiler,123,nrgtotal,total energy,uint24,kWh,false,sensor.boiler_total_energy,sensor.boiler_nrgtotal,6,0,1/100,88,2 -"GB*72, Trendline, Cerapur, Greenstar Si",boiler,123,nrgheat,energy heating,uint24 (>=0<=10000000),kWh,true,number.boiler_energy_heating,number.boiler_nrgheat,6,0,1/100,90,2 +"GB*72, Trendline, Cerapur, Greenstar Si",boiler,123,nompower,nominal Power,uint8 (>=0<=0),kW,true,number.boiler_nominal_Power,number.boiler_nompower,6,0,1,280,1 +"GB*72, Trendline, Cerapur, Greenstar Si",boiler,123,nrgtotal,total energy,uint24,kWh,false,sensor.boiler_total_energy,sensor.boiler_nrgtotal,6,0,1/100,89,2 +"GB*72, Trendline, Cerapur, Greenstar Si",boiler,123,nrgheat,energy heating,uint24 (>=0<=10000000),kWh,true,number.boiler_energy_heating,number.boiler_nrgheat,6,0,1/100,91,2 "GB*72, Trendline, Cerapur, Greenstar Si",boiler,123,dhw.nrg,energy,uint24 (>=0<=10000000),kWh,true,number.boiler_dhw_energy,number.boiler_dhw_nrg,6,9,1/100,0,2 "GB212",boiler,131,reset,reset,cmd [-\|maintenance\|error\|history\|message\|hp error\|burner starts\|factory] (>=0<=0), ,true,sensor.boiler_reset,sensor.boiler_reset,6,0,1,0,1 "GB212",boiler,131,chimneysweeper,chimney sweeper,cmd [off\|on] (>=0<=0), ,true,sensor.boiler_chimney_sweeper,sensor.boiler_chimneysweeper,6,0,1,1,1 @@ -1671,28 +1684,28 @@ device name,device type,product id,shortname,fullname,type [options...] \| (min/ "GB212",boiler,131,syspress,system pressure,uint8,bar,false,sensor.boiler_system_pressure,sensor.boiler_syspress,6,0,1/10,11,1 "GB212",boiler,131,boiltemp,actual boiler temperature,uint16,C,false,sensor.boiler_actual_boiler_temperature,sensor.boiler_boiltemp,6,0,1/10,12,1 "GB212",boiler,131,headertemp,low loss header,uint16,C,false,sensor.boiler_low_loss_header,sensor.boiler_headertemp,6,0,1/10,13,1 -"GB212",boiler,131,exhausttemp,exhaust temperature,uint16,C,false,sensor.boiler_exhaust_temperature,sensor.boiler_exhausttemp,6,0,1/10,253,1 -"GB212",boiler,131,burngas,gas,boolean, ,false,binary_sensor.boiler_gas,binary_sensor.boiler_burngas,6,0,1,254,1 -"GB212",boiler,131,burngas2,gas stage 2,boolean, ,false,binary_sensor.boiler_gas_stage_2,binary_sensor.boiler_burngas2,6,0,1,255,1 -"GB212",boiler,131,flamecurr,flame current,uint16,µA,false,sensor.boiler_flame_current,sensor.boiler_flamecurr,6,0,1/10,256,1 -"GB212",boiler,131,fanwork,fan,boolean, ,false,binary_sensor.boiler_fan,binary_sensor.boiler_fanwork,6,0,1,257,1 -"GB212",boiler,131,ignwork,ignition,boolean, ,false,binary_sensor.boiler_ignition,binary_sensor.boiler_ignwork,6,0,1,258,1 -"GB212",boiler,131,oilpreheat,oil preheating,boolean, ,false,binary_sensor.boiler_oil_preheating,binary_sensor.boiler_oilpreheat,6,0,1,259,1 -"GB212",boiler,131,burnminpower,burner min power,uint8 (>=0<=0),%,true,number.boiler_burner_min_power,number.boiler_burnminpower,6,0,1,260,1 -"GB212",boiler,131,burnmaxpower,burner max power,uint8 (>=0<=254),%,true,number.boiler_burner_max_power,number.boiler_burnmaxpower,6,0,1,261,1 -"GB212",boiler,131,burnminperiod,burner min period,uint8 (>=0<=120),minutes,true,number.boiler_burner_min_period,number.boiler_burnminperiod,6,0,1,262,1 -"GB212",boiler,131,absburnpow,burner current power (absolute),uint8,%,false,sensor.boiler_burner_current_power_(absolute),sensor.boiler_absburnpow,6,0,1,263,1 -"GB212",boiler,131,heatblock,Heatblock temperature,uint16,C,false,sensor.boiler_Heatblock_temperature,sensor.boiler_heatblock,6,0,1/10,264,1 -"GB212",boiler,131,boilhyston,hysteresis on temperature,int8 (>=-20<=0),C,true,number.boiler_hysteresis_on_temperature,number.boiler_boilhyston,6,0,1,265,1 -"GB212",boiler,131,boilhystoff,hysteresis off temperature,int8 (>=0<=20),C,true,number.boiler_hysteresis_off_temperature,number.boiler_boilhystoff,6,0,1,266,1 -"GB212",boiler,131,boil2hyston,hysteresis stage 2 on temperature,int8 (>=-20<=0),C,true,number.boiler_hysteresis_stage_2_on_temperature,number.boiler_boil2hyston,6,0,1,267,1 -"GB212",boiler,131,boil2hystoff,hysteresis stage 2 off temperature,int8 (>=0<=20),C,true,number.boiler_hysteresis_stage_2_off_temperature,number.boiler_boil2hystoff,6,0,1,268,1 -"GB212",boiler,131,curveon,heatingcurve on,boolean (>=0<=0), ,true,switch.boiler_heatingcurve_on,switch.boiler_curveon,6,0,1,269,1 -"GB212",boiler,131,curvebase,heatingcurve base,uint8 (>=20<=90),C,true,number.boiler_heatingcurve_base,number.boiler_curvebase,6,0,1,270,1 -"GB212",boiler,131,curveend,heatingcurve end,uint8 (>=20<=90),C,true,number.boiler_heatingcurve_end,number.boiler_curveend,6,0,1,271,1 -"GB212",boiler,131,summertemp,summer temperature,uint8 (>=0<=45),C,true,number.boiler_summer_temperature,number.boiler_summertemp,6,0,1,272,1 -"GB212",boiler,131,nofrostmode,nofrost mode,boolean (>=0<=0), ,true,switch.boiler_nofrost_mode,switch.boiler_nofrostmode,6,0,1,273,1 -"GB212",boiler,131,nofrosttemp,nofrost temperature,uint8 (>=0<=10),C,true,number.boiler_nofrost_temperature,number.boiler_nofrosttemp,6,0,1,274,1 +"GB212",boiler,131,exhausttemp,exhaust temperature,uint16,C,false,sensor.boiler_exhaust_temperature,sensor.boiler_exhausttemp,6,0,1/10,254,1 +"GB212",boiler,131,burngas,gas,boolean, ,false,binary_sensor.boiler_gas,binary_sensor.boiler_burngas,6,0,1,255,1 +"GB212",boiler,131,burngas2,gas stage 2,boolean, ,false,binary_sensor.boiler_gas_stage_2,binary_sensor.boiler_burngas2,6,0,1,256,1 +"GB212",boiler,131,flamecurr,flame current,uint16,µA,false,sensor.boiler_flame_current,sensor.boiler_flamecurr,6,0,1/10,257,1 +"GB212",boiler,131,fanwork,fan,boolean, ,false,binary_sensor.boiler_fan,binary_sensor.boiler_fanwork,6,0,1,258,1 +"GB212",boiler,131,ignwork,ignition,boolean, ,false,binary_sensor.boiler_ignition,binary_sensor.boiler_ignwork,6,0,1,259,1 +"GB212",boiler,131,oilpreheat,oil preheating,boolean, ,false,binary_sensor.boiler_oil_preheating,binary_sensor.boiler_oilpreheat,6,0,1,260,1 +"GB212",boiler,131,burnminpower,burner min power,uint8 (>=0<=0),%,true,number.boiler_burner_min_power,number.boiler_burnminpower,6,0,1,261,1 +"GB212",boiler,131,burnmaxpower,burner max power,uint8 (>=0<=254),%,true,number.boiler_burner_max_power,number.boiler_burnmaxpower,6,0,1,262,1 +"GB212",boiler,131,burnminperiod,burner min period,uint8 (>=0<=120),minutes,true,number.boiler_burner_min_period,number.boiler_burnminperiod,6,0,1,263,1 +"GB212",boiler,131,absburnpow,burner current power (absolute),uint8,%,false,sensor.boiler_burner_current_power_(absolute),sensor.boiler_absburnpow,6,0,1,264,1 +"GB212",boiler,131,heatblock,Heatblock temperature,uint16,C,false,sensor.boiler_Heatblock_temperature,sensor.boiler_heatblock,6,0,1/10,265,1 +"GB212",boiler,131,boilhyston,hysteresis on temperature,int8 (>=-20<=0),C,true,number.boiler_hysteresis_on_temperature,number.boiler_boilhyston,6,0,1,266,1 +"GB212",boiler,131,boilhystoff,hysteresis off temperature,int8 (>=0<=20),C,true,number.boiler_hysteresis_off_temperature,number.boiler_boilhystoff,6,0,1,267,1 +"GB212",boiler,131,boil2hyston,hysteresis stage 2 on temperature,int8 (>=-20<=0),C,true,number.boiler_hysteresis_stage_2_on_temperature,number.boiler_boil2hyston,6,0,1,268,1 +"GB212",boiler,131,boil2hystoff,hysteresis stage 2 off temperature,int8 (>=0<=20),C,true,number.boiler_hysteresis_stage_2_off_temperature,number.boiler_boil2hystoff,6,0,1,269,1 +"GB212",boiler,131,curveon,heatingcurve on,boolean (>=0<=0), ,true,switch.boiler_heatingcurve_on,switch.boiler_curveon,6,0,1,270,1 +"GB212",boiler,131,curvebase,heatingcurve base,uint8 (>=20<=90),C,true,number.boiler_heatingcurve_base,number.boiler_curvebase,6,0,1,271,1 +"GB212",boiler,131,curveend,heatingcurve end,uint8 (>=20<=90),C,true,number.boiler_heatingcurve_end,number.boiler_curveend,6,0,1,272,1 +"GB212",boiler,131,summertemp,summer temperature,uint8 (>=0<=45),C,true,number.boiler_summer_temperature,number.boiler_summertemp,6,0,1,273,1 +"GB212",boiler,131,nofrostmode,nofrost mode,boolean (>=0<=0), ,true,switch.boiler_nofrost_mode,switch.boiler_nofrostmode,6,0,1,274,1 +"GB212",boiler,131,nofrosttemp,nofrost temperature,uint8 (>=0<=10),C,true,number.boiler_nofrost_temperature,number.boiler_nofrosttemp,6,0,1,275,1 "GB212",boiler,131,heatingactivated,heating activated,boolean (>=0<=0), ,true,switch.boiler_heating_activated,switch.boiler_heatingactivated,6,0,1,14,1 "GB212",boiler,131,heatingtemp,heating temperature,uint8 (>=0<=90),C,true,number.boiler_heating_temperature,number.boiler_heatingtemp,6,0,1,15,1 "GB212",boiler,131,heatingpump,heating pump,boolean, ,false,binary_sensor.boiler_heating_pump,binary_sensor.boiler_heatingpump,6,0,1,16,1 @@ -1719,18 +1732,19 @@ device name,device type,product id,shortname,fullname,type [options...] \| (min/ "GB212",boiler,131,maintenancedate,next maintenance date,string (>=0<=0), ,true,sensor.boiler_next_maintenance_date,sensor.boiler_maintenancedate,6,0,1,72,6 "GB212",boiler,131,emergencyops,emergency operation,boolean (>=0<=0), ,true,switch.boiler_emergency_operation,switch.boiler_emergencyops,6,0,1,78,1 "GB212",boiler,131,emergencytemp,emergency temperature,uint8 (>=15<=70),C,true,number.boiler_emergency_temperature,number.boiler_emergencytemp,6,0,1,79,1 -"GB212",boiler,131,pc0flow,Flow PC0,int16,l/h,false,sensor.boiler_Flow_PC0,sensor.boiler_pc0flow,6,0,1,80,1 -"GB212",boiler,131,pc1flow,Flow PC1,int16,l/h,false,sensor.boiler_Flow_PC1,sensor.boiler_pc1flow,6,0,1,81,1 -"GB212",boiler,131,pc1on,PC1,boolean, ,false,binary_sensor.boiler_PC1,binary_sensor.boiler_pc1on,6,0,1,82,1 -"GB212",boiler,131,pc1rate,PC1 rate,uint8,%,false,sensor.boiler_PC1_rate,sensor.boiler_pc1rate,6,0,1,83,1 -"GB212",boiler,131,pumpkickhour,pump kick hour,uint8 (>=0<=23),hours,true,number.boiler_pump_kick_hour,number.boiler_pumpkickhour,6,0,1,84,1 -"GB212",boiler,131,pumpkickday,pump kick day,enum [mo\|tu\|we\|th\|fr\|sa\|su\|all] (>=0<=0), ,true,select.boiler_pump_kick_day,select.boiler_pumpkickday,6,0,1,85,1 -"GB212",boiler,131,pumpkickdelay,pump kick delay,uint16 (>=0<=32767),minutes,true,number.boiler_pump_kick_delay,number.boiler_pumpkickdelay,6,0,1,86,1 -"GB212",boiler,131,meterheat,meter heating,uint24,kWh,false,sensor.boiler_meter_heating,sensor.boiler_meterheat,6,0,1/10,100,2 +"GB212",boiler,131,pc0lpm,Flow PC0,uint16,l/min,false,sensor.boiler_Flow_PC0,sensor.boiler_pc0lpm,6,0,1/10,80,1 +"GB212",boiler,131,pc0flow,Flow PC0,uint16,l/h,false,sensor.boiler_Flow_PC0,sensor.boiler_pc0flow,6,0,1,81,1 +"GB212",boiler,131,pc1flow,Flow PC1,uint16,l/h,false,sensor.boiler_Flow_PC1,sensor.boiler_pc1flow,6,0,1,82,1 +"GB212",boiler,131,pc1on,PC1,boolean, ,false,binary_sensor.boiler_PC1,binary_sensor.boiler_pc1on,6,0,1,83,1 +"GB212",boiler,131,pc1rate,PC1 rate,uint8,%,false,sensor.boiler_PC1_rate,sensor.boiler_pc1rate,6,0,1,84,1 +"GB212",boiler,131,pumpkickhour,pump kick hour,uint8 (>=0<=23),hours,true,number.boiler_pump_kick_hour,number.boiler_pumpkickhour,6,0,1,85,1 +"GB212",boiler,131,pumpkickday,pump kick day,enum [mo\|tu\|we\|th\|fr\|sa\|su\|all] (>=0<=0), ,true,select.boiler_pump_kick_day,select.boiler_pumpkickday,6,0,1,86,1 +"GB212",boiler,131,pumpkickdelay,pump kick delay,uint16 (>=0<=32767),minutes,true,number.boiler_pump_kick_delay,number.boiler_pumpkickdelay,6,0,1,87,1 +"GB212",boiler,131,meterheat,meter heating,uint24,kWh,false,sensor.boiler_meter_heating,sensor.boiler_meterheat,6,0,1/10,101,2 "GB212",boiler,131,dhw.meter,meter,uint24,kWh,false,sensor.boiler_dhw_meter,sensor.boiler_dhw_meter,6,9,1/10,2,2 -"GB212",boiler,131,gasmeterheat,gas meter heating,uint24,kWh,false,sensor.boiler_gas_meter_heating,sensor.boiler_gasmeterheat,6,0,1/10,275,2 +"GB212",boiler,131,gasmeterheat,gas meter heating,uint24,kWh,false,sensor.boiler_gas_meter_heating,sensor.boiler_gasmeterheat,6,0,1/10,276,2 "GB212",boiler,131,dhw.gasmeter,gas meter,uint24,kWh,false,sensor.boiler_dhw_gas_meter,sensor.boiler_dhw_gasmeter,6,9,1/10,71,2 -"GB212",boiler,131,nrgheat2,energy heating 2,uint24,kWh,false,sensor.boiler_energy_heating_2,sensor.boiler_nrgheat2,6,0,1/10,277,2 +"GB212",boiler,131,nrgheat2,energy heating 2,uint24,kWh,false,sensor.boiler_energy_heating_2,sensor.boiler_nrgheat2,6,0,1/10,278,2 "GB212",boiler,131,dhw.nrg2,energy 2,uint24,kWh,false,sensor.boiler_dhw_energy_2,sensor.boiler_dhw_nrg2,6,9,1/10,73,2 "GB212",boiler,131,dhw.tapactivated,turn on/off,boolean (>=0<=0), ,true,switch.boiler_dhw_turn_on/off,switch.boiler_dhw_tapactivated,6,9,1,28,1 "GB212",boiler,131,dhw.settemp,set temperature,uint8,C,false,sensor.boiler_dhw_set_temperature,sensor.boiler_dhw_settemp,6,9,1,29,1 @@ -1773,9 +1787,9 @@ device name,device type,product id,shortname,fullname,type [options...] \| (min/ "GB212",boiler,131,dhw.dhwprio,dhw priority,boolean (>=0<=0), ,true,switch.boiler_dhw_dhw_priority,switch.boiler_dhw_dhwprio,6,9,1,66,1 "GB212",boiler,131,dhw.starts,starts,uint24, ,false,sensor.boiler_dhw_starts,sensor.boiler_dhw_starts,6,9,1,67,2 "GB212",boiler,131,dhw.workm,active time,time,minutes,false,sensor.boiler_dhw_active_time,sensor.boiler_dhw_workm,6,9,1,69,2 -"GB212",boiler,131,nompower,nominal Power,uint8 (>=0<=0),kW,true,number.boiler_nominal_Power,number.boiler_nompower,6,0,1,279,1 -"GB212",boiler,131,nrgtotal,total energy,uint24,kWh,false,sensor.boiler_total_energy,sensor.boiler_nrgtotal,6,0,1/100,88,2 -"GB212",boiler,131,nrgheat,energy heating,uint24 (>=0<=10000000),kWh,true,number.boiler_energy_heating,number.boiler_nrgheat,6,0,1/100,90,2 +"GB212",boiler,131,nompower,nominal Power,uint8 (>=0<=0),kW,true,number.boiler_nominal_Power,number.boiler_nompower,6,0,1,280,1 +"GB212",boiler,131,nrgtotal,total energy,uint24,kWh,false,sensor.boiler_total_energy,sensor.boiler_nrgtotal,6,0,1/100,89,2 +"GB212",boiler,131,nrgheat,energy heating,uint24 (>=0<=10000000),kWh,true,number.boiler_energy_heating,number.boiler_nrgheat,6,0,1/100,91,2 "GB212",boiler,131,dhw.nrg,energy,uint24 (>=0<=10000000),kWh,true,number.boiler_dhw_energy,number.boiler_dhw_nrg,6,9,1/100,0,2 "GC7000F",boiler,132,reset,reset,cmd [-\|maintenance\|error\|history\|message\|hp error\|burner starts\|factory] (>=0<=0), ,true,sensor.boiler_reset,sensor.boiler_reset,6,0,1,0,1 "GC7000F",boiler,132,chimneysweeper,chimney sweeper,cmd [off\|on] (>=0<=0), ,true,sensor.boiler_chimney_sweeper,sensor.boiler_chimneysweeper,6,0,1,1,1 @@ -1791,28 +1805,28 @@ device name,device type,product id,shortname,fullname,type [options...] \| (min/ "GC7000F",boiler,132,syspress,system pressure,uint8,bar,false,sensor.boiler_system_pressure,sensor.boiler_syspress,6,0,1/10,11,1 "GC7000F",boiler,132,boiltemp,actual boiler temperature,uint16,C,false,sensor.boiler_actual_boiler_temperature,sensor.boiler_boiltemp,6,0,1/10,12,1 "GC7000F",boiler,132,headertemp,low loss header,uint16,C,false,sensor.boiler_low_loss_header,sensor.boiler_headertemp,6,0,1/10,13,1 -"GC7000F",boiler,132,exhausttemp,exhaust temperature,uint16,C,false,sensor.boiler_exhaust_temperature,sensor.boiler_exhausttemp,6,0,1/10,253,1 -"GC7000F",boiler,132,burngas,gas,boolean, ,false,binary_sensor.boiler_gas,binary_sensor.boiler_burngas,6,0,1,254,1 -"GC7000F",boiler,132,burngas2,gas stage 2,boolean, ,false,binary_sensor.boiler_gas_stage_2,binary_sensor.boiler_burngas2,6,0,1,255,1 -"GC7000F",boiler,132,flamecurr,flame current,uint16,µA,false,sensor.boiler_flame_current,sensor.boiler_flamecurr,6,0,1/10,256,1 -"GC7000F",boiler,132,fanwork,fan,boolean, ,false,binary_sensor.boiler_fan,binary_sensor.boiler_fanwork,6,0,1,257,1 -"GC7000F",boiler,132,ignwork,ignition,boolean, ,false,binary_sensor.boiler_ignition,binary_sensor.boiler_ignwork,6,0,1,258,1 -"GC7000F",boiler,132,oilpreheat,oil preheating,boolean, ,false,binary_sensor.boiler_oil_preheating,binary_sensor.boiler_oilpreheat,6,0,1,259,1 -"GC7000F",boiler,132,burnminpower,burner min power,uint8 (>=0<=0),%,true,number.boiler_burner_min_power,number.boiler_burnminpower,6,0,1,260,1 -"GC7000F",boiler,132,burnmaxpower,burner max power,uint8 (>=0<=254),%,true,number.boiler_burner_max_power,number.boiler_burnmaxpower,6,0,1,261,1 -"GC7000F",boiler,132,burnminperiod,burner min period,uint8 (>=0<=120),minutes,true,number.boiler_burner_min_period,number.boiler_burnminperiod,6,0,1,262,1 -"GC7000F",boiler,132,absburnpow,burner current power (absolute),uint8,%,false,sensor.boiler_burner_current_power_(absolute),sensor.boiler_absburnpow,6,0,1,263,1 -"GC7000F",boiler,132,heatblock,Heatblock temperature,uint16,C,false,sensor.boiler_Heatblock_temperature,sensor.boiler_heatblock,6,0,1/10,264,1 -"GC7000F",boiler,132,boilhyston,hysteresis on temperature,int8 (>=-20<=0),C,true,number.boiler_hysteresis_on_temperature,number.boiler_boilhyston,6,0,1,265,1 -"GC7000F",boiler,132,boilhystoff,hysteresis off temperature,int8 (>=0<=20),C,true,number.boiler_hysteresis_off_temperature,number.boiler_boilhystoff,6,0,1,266,1 -"GC7000F",boiler,132,boil2hyston,hysteresis stage 2 on temperature,int8 (>=-20<=0),C,true,number.boiler_hysteresis_stage_2_on_temperature,number.boiler_boil2hyston,6,0,1,267,1 -"GC7000F",boiler,132,boil2hystoff,hysteresis stage 2 off temperature,int8 (>=0<=20),C,true,number.boiler_hysteresis_stage_2_off_temperature,number.boiler_boil2hystoff,6,0,1,268,1 -"GC7000F",boiler,132,curveon,heatingcurve on,boolean (>=0<=0), ,true,switch.boiler_heatingcurve_on,switch.boiler_curveon,6,0,1,269,1 -"GC7000F",boiler,132,curvebase,heatingcurve base,uint8 (>=20<=90),C,true,number.boiler_heatingcurve_base,number.boiler_curvebase,6,0,1,270,1 -"GC7000F",boiler,132,curveend,heatingcurve end,uint8 (>=20<=90),C,true,number.boiler_heatingcurve_end,number.boiler_curveend,6,0,1,271,1 -"GC7000F",boiler,132,summertemp,summer temperature,uint8 (>=0<=45),C,true,number.boiler_summer_temperature,number.boiler_summertemp,6,0,1,272,1 -"GC7000F",boiler,132,nofrostmode,nofrost mode,boolean (>=0<=0), ,true,switch.boiler_nofrost_mode,switch.boiler_nofrostmode,6,0,1,273,1 -"GC7000F",boiler,132,nofrosttemp,nofrost temperature,uint8 (>=0<=10),C,true,number.boiler_nofrost_temperature,number.boiler_nofrosttemp,6,0,1,274,1 +"GC7000F",boiler,132,exhausttemp,exhaust temperature,uint16,C,false,sensor.boiler_exhaust_temperature,sensor.boiler_exhausttemp,6,0,1/10,254,1 +"GC7000F",boiler,132,burngas,gas,boolean, ,false,binary_sensor.boiler_gas,binary_sensor.boiler_burngas,6,0,1,255,1 +"GC7000F",boiler,132,burngas2,gas stage 2,boolean, ,false,binary_sensor.boiler_gas_stage_2,binary_sensor.boiler_burngas2,6,0,1,256,1 +"GC7000F",boiler,132,flamecurr,flame current,uint16,µA,false,sensor.boiler_flame_current,sensor.boiler_flamecurr,6,0,1/10,257,1 +"GC7000F",boiler,132,fanwork,fan,boolean, ,false,binary_sensor.boiler_fan,binary_sensor.boiler_fanwork,6,0,1,258,1 +"GC7000F",boiler,132,ignwork,ignition,boolean, ,false,binary_sensor.boiler_ignition,binary_sensor.boiler_ignwork,6,0,1,259,1 +"GC7000F",boiler,132,oilpreheat,oil preheating,boolean, ,false,binary_sensor.boiler_oil_preheating,binary_sensor.boiler_oilpreheat,6,0,1,260,1 +"GC7000F",boiler,132,burnminpower,burner min power,uint8 (>=0<=0),%,true,number.boiler_burner_min_power,number.boiler_burnminpower,6,0,1,261,1 +"GC7000F",boiler,132,burnmaxpower,burner max power,uint8 (>=0<=254),%,true,number.boiler_burner_max_power,number.boiler_burnmaxpower,6,0,1,262,1 +"GC7000F",boiler,132,burnminperiod,burner min period,uint8 (>=0<=120),minutes,true,number.boiler_burner_min_period,number.boiler_burnminperiod,6,0,1,263,1 +"GC7000F",boiler,132,absburnpow,burner current power (absolute),uint8,%,false,sensor.boiler_burner_current_power_(absolute),sensor.boiler_absburnpow,6,0,1,264,1 +"GC7000F",boiler,132,heatblock,Heatblock temperature,uint16,C,false,sensor.boiler_Heatblock_temperature,sensor.boiler_heatblock,6,0,1/10,265,1 +"GC7000F",boiler,132,boilhyston,hysteresis on temperature,int8 (>=-20<=0),C,true,number.boiler_hysteresis_on_temperature,number.boiler_boilhyston,6,0,1,266,1 +"GC7000F",boiler,132,boilhystoff,hysteresis off temperature,int8 (>=0<=20),C,true,number.boiler_hysteresis_off_temperature,number.boiler_boilhystoff,6,0,1,267,1 +"GC7000F",boiler,132,boil2hyston,hysteresis stage 2 on temperature,int8 (>=-20<=0),C,true,number.boiler_hysteresis_stage_2_on_temperature,number.boiler_boil2hyston,6,0,1,268,1 +"GC7000F",boiler,132,boil2hystoff,hysteresis stage 2 off temperature,int8 (>=0<=20),C,true,number.boiler_hysteresis_stage_2_off_temperature,number.boiler_boil2hystoff,6,0,1,269,1 +"GC7000F",boiler,132,curveon,heatingcurve on,boolean (>=0<=0), ,true,switch.boiler_heatingcurve_on,switch.boiler_curveon,6,0,1,270,1 +"GC7000F",boiler,132,curvebase,heatingcurve base,uint8 (>=20<=90),C,true,number.boiler_heatingcurve_base,number.boiler_curvebase,6,0,1,271,1 +"GC7000F",boiler,132,curveend,heatingcurve end,uint8 (>=20<=90),C,true,number.boiler_heatingcurve_end,number.boiler_curveend,6,0,1,272,1 +"GC7000F",boiler,132,summertemp,summer temperature,uint8 (>=0<=45),C,true,number.boiler_summer_temperature,number.boiler_summertemp,6,0,1,273,1 +"GC7000F",boiler,132,nofrostmode,nofrost mode,boolean (>=0<=0), ,true,switch.boiler_nofrost_mode,switch.boiler_nofrostmode,6,0,1,274,1 +"GC7000F",boiler,132,nofrosttemp,nofrost temperature,uint8 (>=0<=10),C,true,number.boiler_nofrost_temperature,number.boiler_nofrosttemp,6,0,1,275,1 "GC7000F",boiler,132,heatingactivated,heating activated,boolean (>=0<=0), ,true,switch.boiler_heating_activated,switch.boiler_heatingactivated,6,0,1,14,1 "GC7000F",boiler,132,heatingtemp,heating temperature,uint8 (>=0<=90),C,true,number.boiler_heating_temperature,number.boiler_heatingtemp,6,0,1,15,1 "GC7000F",boiler,132,heatingpump,heating pump,boolean, ,false,binary_sensor.boiler_heating_pump,binary_sensor.boiler_heatingpump,6,0,1,16,1 @@ -1839,18 +1853,19 @@ device name,device type,product id,shortname,fullname,type [options...] \| (min/ "GC7000F",boiler,132,maintenancedate,next maintenance date,string (>=0<=0), ,true,sensor.boiler_next_maintenance_date,sensor.boiler_maintenancedate,6,0,1,72,6 "GC7000F",boiler,132,emergencyops,emergency operation,boolean (>=0<=0), ,true,switch.boiler_emergency_operation,switch.boiler_emergencyops,6,0,1,78,1 "GC7000F",boiler,132,emergencytemp,emergency temperature,uint8 (>=15<=70),C,true,number.boiler_emergency_temperature,number.boiler_emergencytemp,6,0,1,79,1 -"GC7000F",boiler,132,pc0flow,Flow PC0,int16,l/h,false,sensor.boiler_Flow_PC0,sensor.boiler_pc0flow,6,0,1,80,1 -"GC7000F",boiler,132,pc1flow,Flow PC1,int16,l/h,false,sensor.boiler_Flow_PC1,sensor.boiler_pc1flow,6,0,1,81,1 -"GC7000F",boiler,132,pc1on,PC1,boolean, ,false,binary_sensor.boiler_PC1,binary_sensor.boiler_pc1on,6,0,1,82,1 -"GC7000F",boiler,132,pc1rate,PC1 rate,uint8,%,false,sensor.boiler_PC1_rate,sensor.boiler_pc1rate,6,0,1,83,1 -"GC7000F",boiler,132,pumpkickhour,pump kick hour,uint8 (>=0<=23),hours,true,number.boiler_pump_kick_hour,number.boiler_pumpkickhour,6,0,1,84,1 -"GC7000F",boiler,132,pumpkickday,pump kick day,enum [mo\|tu\|we\|th\|fr\|sa\|su\|all] (>=0<=0), ,true,select.boiler_pump_kick_day,select.boiler_pumpkickday,6,0,1,85,1 -"GC7000F",boiler,132,pumpkickdelay,pump kick delay,uint16 (>=0<=32767),minutes,true,number.boiler_pump_kick_delay,number.boiler_pumpkickdelay,6,0,1,86,1 -"GC7000F",boiler,132,meterheat,meter heating,uint24,kWh,false,sensor.boiler_meter_heating,sensor.boiler_meterheat,6,0,1/10,100,2 +"GC7000F",boiler,132,pc0lpm,Flow PC0,uint16,l/min,false,sensor.boiler_Flow_PC0,sensor.boiler_pc0lpm,6,0,1/10,80,1 +"GC7000F",boiler,132,pc0flow,Flow PC0,uint16,l/h,false,sensor.boiler_Flow_PC0,sensor.boiler_pc0flow,6,0,1,81,1 +"GC7000F",boiler,132,pc1flow,Flow PC1,uint16,l/h,false,sensor.boiler_Flow_PC1,sensor.boiler_pc1flow,6,0,1,82,1 +"GC7000F",boiler,132,pc1on,PC1,boolean, ,false,binary_sensor.boiler_PC1,binary_sensor.boiler_pc1on,6,0,1,83,1 +"GC7000F",boiler,132,pc1rate,PC1 rate,uint8,%,false,sensor.boiler_PC1_rate,sensor.boiler_pc1rate,6,0,1,84,1 +"GC7000F",boiler,132,pumpkickhour,pump kick hour,uint8 (>=0<=23),hours,true,number.boiler_pump_kick_hour,number.boiler_pumpkickhour,6,0,1,85,1 +"GC7000F",boiler,132,pumpkickday,pump kick day,enum [mo\|tu\|we\|th\|fr\|sa\|su\|all] (>=0<=0), ,true,select.boiler_pump_kick_day,select.boiler_pumpkickday,6,0,1,86,1 +"GC7000F",boiler,132,pumpkickdelay,pump kick delay,uint16 (>=0<=32767),minutes,true,number.boiler_pump_kick_delay,number.boiler_pumpkickdelay,6,0,1,87,1 +"GC7000F",boiler,132,meterheat,meter heating,uint24,kWh,false,sensor.boiler_meter_heating,sensor.boiler_meterheat,6,0,1/10,101,2 "GC7000F",boiler,132,dhw.meter,meter,uint24,kWh,false,sensor.boiler_dhw_meter,sensor.boiler_dhw_meter,6,9,1/10,2,2 -"GC7000F",boiler,132,gasmeterheat,gas meter heating,uint24,kWh,false,sensor.boiler_gas_meter_heating,sensor.boiler_gasmeterheat,6,0,1/10,275,2 +"GC7000F",boiler,132,gasmeterheat,gas meter heating,uint24,kWh,false,sensor.boiler_gas_meter_heating,sensor.boiler_gasmeterheat,6,0,1/10,276,2 "GC7000F",boiler,132,dhw.gasmeter,gas meter,uint24,kWh,false,sensor.boiler_dhw_gas_meter,sensor.boiler_dhw_gasmeter,6,9,1/10,71,2 -"GC7000F",boiler,132,nrgheat2,energy heating 2,uint24,kWh,false,sensor.boiler_energy_heating_2,sensor.boiler_nrgheat2,6,0,1/10,277,2 +"GC7000F",boiler,132,nrgheat2,energy heating 2,uint24,kWh,false,sensor.boiler_energy_heating_2,sensor.boiler_nrgheat2,6,0,1/10,278,2 "GC7000F",boiler,132,dhw.nrg2,energy 2,uint24,kWh,false,sensor.boiler_dhw_energy_2,sensor.boiler_dhw_nrg2,6,9,1/10,73,2 "GC7000F",boiler,132,dhw.tapactivated,turn on/off,boolean (>=0<=0), ,true,switch.boiler_dhw_turn_on/off,switch.boiler_dhw_tapactivated,6,9,1,28,1 "GC7000F",boiler,132,dhw.settemp,set temperature,uint8,C,false,sensor.boiler_dhw_set_temperature,sensor.boiler_dhw_settemp,6,9,1,29,1 @@ -1893,9 +1908,9 @@ device name,device type,product id,shortname,fullname,type [options...] \| (min/ "GC7000F",boiler,132,dhw.dhwprio,dhw priority,boolean (>=0<=0), ,true,switch.boiler_dhw_dhw_priority,switch.boiler_dhw_dhwprio,6,9,1,66,1 "GC7000F",boiler,132,dhw.starts,starts,uint24, ,false,sensor.boiler_dhw_starts,sensor.boiler_dhw_starts,6,9,1,67,2 "GC7000F",boiler,132,dhw.workm,active time,time,minutes,false,sensor.boiler_dhw_active_time,sensor.boiler_dhw_workm,6,9,1,69,2 -"GC7000F",boiler,132,nompower,nominal Power,uint8 (>=0<=0),kW,true,number.boiler_nominal_Power,number.boiler_nompower,6,0,1,279,1 -"GC7000F",boiler,132,nrgtotal,total energy,uint24,kWh,false,sensor.boiler_total_energy,sensor.boiler_nrgtotal,6,0,1/100,88,2 -"GC7000F",boiler,132,nrgheat,energy heating,uint24 (>=0<=10000000),kWh,true,number.boiler_energy_heating,number.boiler_nrgheat,6,0,1/100,90,2 +"GC7000F",boiler,132,nompower,nominal Power,uint8 (>=0<=0),kW,true,number.boiler_nominal_Power,number.boiler_nompower,6,0,1,280,1 +"GC7000F",boiler,132,nrgtotal,total energy,uint24,kWh,false,sensor.boiler_total_energy,sensor.boiler_nrgtotal,6,0,1/100,89,2 +"GC7000F",boiler,132,nrgheat,energy heating,uint24 (>=0<=10000000),kWh,true,number.boiler_energy_heating,number.boiler_nrgheat,6,0,1/100,91,2 "GC7000F",boiler,132,dhw.nrg,energy,uint24 (>=0<=10000000),kWh,true,number.boiler_dhw_energy,number.boiler_dhw_nrg,6,9,1/100,0,2 "Logano GB125/KB195i, Logamatic MC110",boiler,133,reset,reset,cmd [-\|maintenance\|error\|history\|message\|hp error\|burner starts\|factory] (>=0<=0), ,true,sensor.boiler_reset,sensor.boiler_reset,6,0,1,0,1 "Logano GB125/KB195i, Logamatic MC110",boiler,133,chimneysweeper,chimney sweeper,cmd [off\|on] (>=0<=0), ,true,sensor.boiler_chimney_sweeper,sensor.boiler_chimneysweeper,6,0,1,1,1 @@ -1911,28 +1926,28 @@ device name,device type,product id,shortname,fullname,type [options...] \| (min/ "Logano GB125/KB195i, Logamatic MC110",boiler,133,syspress,system pressure,uint8,bar,false,sensor.boiler_system_pressure,sensor.boiler_syspress,6,0,1/10,11,1 "Logano GB125/KB195i, Logamatic MC110",boiler,133,boiltemp,actual boiler temperature,uint16,C,false,sensor.boiler_actual_boiler_temperature,sensor.boiler_boiltemp,6,0,1/10,12,1 "Logano GB125/KB195i, Logamatic MC110",boiler,133,headertemp,low loss header,uint16,C,false,sensor.boiler_low_loss_header,sensor.boiler_headertemp,6,0,1/10,13,1 -"Logano GB125/KB195i, Logamatic MC110",boiler,133,exhausttemp,exhaust temperature,uint16,C,false,sensor.boiler_exhaust_temperature,sensor.boiler_exhausttemp,6,0,1/10,253,1 -"Logano GB125/KB195i, Logamatic MC110",boiler,133,burngas,gas,boolean, ,false,binary_sensor.boiler_gas,binary_sensor.boiler_burngas,6,0,1,254,1 -"Logano GB125/KB195i, Logamatic MC110",boiler,133,burngas2,gas stage 2,boolean, ,false,binary_sensor.boiler_gas_stage_2,binary_sensor.boiler_burngas2,6,0,1,255,1 -"Logano GB125/KB195i, Logamatic MC110",boiler,133,flamecurr,flame current,uint16,µA,false,sensor.boiler_flame_current,sensor.boiler_flamecurr,6,0,1/10,256,1 -"Logano GB125/KB195i, Logamatic MC110",boiler,133,fanwork,fan,boolean, ,false,binary_sensor.boiler_fan,binary_sensor.boiler_fanwork,6,0,1,257,1 -"Logano GB125/KB195i, Logamatic MC110",boiler,133,ignwork,ignition,boolean, ,false,binary_sensor.boiler_ignition,binary_sensor.boiler_ignwork,6,0,1,258,1 -"Logano GB125/KB195i, Logamatic MC110",boiler,133,oilpreheat,oil preheating,boolean, ,false,binary_sensor.boiler_oil_preheating,binary_sensor.boiler_oilpreheat,6,0,1,259,1 -"Logano GB125/KB195i, Logamatic MC110",boiler,133,burnminpower,burner min power,uint8 (>=0<=0),%,true,number.boiler_burner_min_power,number.boiler_burnminpower,6,0,1,260,1 -"Logano GB125/KB195i, Logamatic MC110",boiler,133,burnmaxpower,burner max power,uint8 (>=0<=254),%,true,number.boiler_burner_max_power,number.boiler_burnmaxpower,6,0,1,261,1 -"Logano GB125/KB195i, Logamatic MC110",boiler,133,burnminperiod,burner min period,uint8 (>=0<=120),minutes,true,number.boiler_burner_min_period,number.boiler_burnminperiod,6,0,1,262,1 -"Logano GB125/KB195i, Logamatic MC110",boiler,133,absburnpow,burner current power (absolute),uint8,%,false,sensor.boiler_burner_current_power_(absolute),sensor.boiler_absburnpow,6,0,1,263,1 -"Logano GB125/KB195i, Logamatic MC110",boiler,133,heatblock,Heatblock temperature,uint16,C,false,sensor.boiler_Heatblock_temperature,sensor.boiler_heatblock,6,0,1/10,264,1 -"Logano GB125/KB195i, Logamatic MC110",boiler,133,boilhyston,hysteresis on temperature,int8 (>=-20<=0),C,true,number.boiler_hysteresis_on_temperature,number.boiler_boilhyston,6,0,1,265,1 -"Logano GB125/KB195i, Logamatic MC110",boiler,133,boilhystoff,hysteresis off temperature,int8 (>=0<=20),C,true,number.boiler_hysteresis_off_temperature,number.boiler_boilhystoff,6,0,1,266,1 -"Logano GB125/KB195i, Logamatic MC110",boiler,133,boil2hyston,hysteresis stage 2 on temperature,int8 (>=-20<=0),C,true,number.boiler_hysteresis_stage_2_on_temperature,number.boiler_boil2hyston,6,0,1,267,1 -"Logano GB125/KB195i, Logamatic MC110",boiler,133,boil2hystoff,hysteresis stage 2 off temperature,int8 (>=0<=20),C,true,number.boiler_hysteresis_stage_2_off_temperature,number.boiler_boil2hystoff,6,0,1,268,1 -"Logano GB125/KB195i, Logamatic MC110",boiler,133,curveon,heatingcurve on,boolean (>=0<=0), ,true,switch.boiler_heatingcurve_on,switch.boiler_curveon,6,0,1,269,1 -"Logano GB125/KB195i, Logamatic MC110",boiler,133,curvebase,heatingcurve base,uint8 (>=20<=90),C,true,number.boiler_heatingcurve_base,number.boiler_curvebase,6,0,1,270,1 -"Logano GB125/KB195i, Logamatic MC110",boiler,133,curveend,heatingcurve end,uint8 (>=20<=90),C,true,number.boiler_heatingcurve_end,number.boiler_curveend,6,0,1,271,1 -"Logano GB125/KB195i, Logamatic MC110",boiler,133,summertemp,summer temperature,uint8 (>=0<=45),C,true,number.boiler_summer_temperature,number.boiler_summertemp,6,0,1,272,1 -"Logano GB125/KB195i, Logamatic MC110",boiler,133,nofrostmode,nofrost mode,boolean (>=0<=0), ,true,switch.boiler_nofrost_mode,switch.boiler_nofrostmode,6,0,1,273,1 -"Logano GB125/KB195i, Logamatic MC110",boiler,133,nofrosttemp,nofrost temperature,uint8 (>=0<=10),C,true,number.boiler_nofrost_temperature,number.boiler_nofrosttemp,6,0,1,274,1 +"Logano GB125/KB195i, Logamatic MC110",boiler,133,exhausttemp,exhaust temperature,uint16,C,false,sensor.boiler_exhaust_temperature,sensor.boiler_exhausttemp,6,0,1/10,254,1 +"Logano GB125/KB195i, Logamatic MC110",boiler,133,burngas,gas,boolean, ,false,binary_sensor.boiler_gas,binary_sensor.boiler_burngas,6,0,1,255,1 +"Logano GB125/KB195i, Logamatic MC110",boiler,133,burngas2,gas stage 2,boolean, ,false,binary_sensor.boiler_gas_stage_2,binary_sensor.boiler_burngas2,6,0,1,256,1 +"Logano GB125/KB195i, Logamatic MC110",boiler,133,flamecurr,flame current,uint16,µA,false,sensor.boiler_flame_current,sensor.boiler_flamecurr,6,0,1/10,257,1 +"Logano GB125/KB195i, Logamatic MC110",boiler,133,fanwork,fan,boolean, ,false,binary_sensor.boiler_fan,binary_sensor.boiler_fanwork,6,0,1,258,1 +"Logano GB125/KB195i, Logamatic MC110",boiler,133,ignwork,ignition,boolean, ,false,binary_sensor.boiler_ignition,binary_sensor.boiler_ignwork,6,0,1,259,1 +"Logano GB125/KB195i, Logamatic MC110",boiler,133,oilpreheat,oil preheating,boolean, ,false,binary_sensor.boiler_oil_preheating,binary_sensor.boiler_oilpreheat,6,0,1,260,1 +"Logano GB125/KB195i, Logamatic MC110",boiler,133,burnminpower,burner min power,uint8 (>=0<=0),%,true,number.boiler_burner_min_power,number.boiler_burnminpower,6,0,1,261,1 +"Logano GB125/KB195i, Logamatic MC110",boiler,133,burnmaxpower,burner max power,uint8 (>=0<=254),%,true,number.boiler_burner_max_power,number.boiler_burnmaxpower,6,0,1,262,1 +"Logano GB125/KB195i, Logamatic MC110",boiler,133,burnminperiod,burner min period,uint8 (>=0<=120),minutes,true,number.boiler_burner_min_period,number.boiler_burnminperiod,6,0,1,263,1 +"Logano GB125/KB195i, Logamatic MC110",boiler,133,absburnpow,burner current power (absolute),uint8,%,false,sensor.boiler_burner_current_power_(absolute),sensor.boiler_absburnpow,6,0,1,264,1 +"Logano GB125/KB195i, Logamatic MC110",boiler,133,heatblock,Heatblock temperature,uint16,C,false,sensor.boiler_Heatblock_temperature,sensor.boiler_heatblock,6,0,1/10,265,1 +"Logano GB125/KB195i, Logamatic MC110",boiler,133,boilhyston,hysteresis on temperature,int8 (>=-20<=0),C,true,number.boiler_hysteresis_on_temperature,number.boiler_boilhyston,6,0,1,266,1 +"Logano GB125/KB195i, Logamatic MC110",boiler,133,boilhystoff,hysteresis off temperature,int8 (>=0<=20),C,true,number.boiler_hysteresis_off_temperature,number.boiler_boilhystoff,6,0,1,267,1 +"Logano GB125/KB195i, Logamatic MC110",boiler,133,boil2hyston,hysteresis stage 2 on temperature,int8 (>=-20<=0),C,true,number.boiler_hysteresis_stage_2_on_temperature,number.boiler_boil2hyston,6,0,1,268,1 +"Logano GB125/KB195i, Logamatic MC110",boiler,133,boil2hystoff,hysteresis stage 2 off temperature,int8 (>=0<=20),C,true,number.boiler_hysteresis_stage_2_off_temperature,number.boiler_boil2hystoff,6,0,1,269,1 +"Logano GB125/KB195i, Logamatic MC110",boiler,133,curveon,heatingcurve on,boolean (>=0<=0), ,true,switch.boiler_heatingcurve_on,switch.boiler_curveon,6,0,1,270,1 +"Logano GB125/KB195i, Logamatic MC110",boiler,133,curvebase,heatingcurve base,uint8 (>=20<=90),C,true,number.boiler_heatingcurve_base,number.boiler_curvebase,6,0,1,271,1 +"Logano GB125/KB195i, Logamatic MC110",boiler,133,curveend,heatingcurve end,uint8 (>=20<=90),C,true,number.boiler_heatingcurve_end,number.boiler_curveend,6,0,1,272,1 +"Logano GB125/KB195i, Logamatic MC110",boiler,133,summertemp,summer temperature,uint8 (>=0<=45),C,true,number.boiler_summer_temperature,number.boiler_summertemp,6,0,1,273,1 +"Logano GB125/KB195i, Logamatic MC110",boiler,133,nofrostmode,nofrost mode,boolean (>=0<=0), ,true,switch.boiler_nofrost_mode,switch.boiler_nofrostmode,6,0,1,274,1 +"Logano GB125/KB195i, Logamatic MC110",boiler,133,nofrosttemp,nofrost temperature,uint8 (>=0<=10),C,true,number.boiler_nofrost_temperature,number.boiler_nofrosttemp,6,0,1,275,1 "Logano GB125/KB195i, Logamatic MC110",boiler,133,heatingactivated,heating activated,boolean (>=0<=0), ,true,switch.boiler_heating_activated,switch.boiler_heatingactivated,6,0,1,14,1 "Logano GB125/KB195i, Logamatic MC110",boiler,133,heatingtemp,heating temperature,uint8 (>=0<=90),C,true,number.boiler_heating_temperature,number.boiler_heatingtemp,6,0,1,15,1 "Logano GB125/KB195i, Logamatic MC110",boiler,133,heatingpump,heating pump,boolean, ,false,binary_sensor.boiler_heating_pump,binary_sensor.boiler_heatingpump,6,0,1,16,1 @@ -1959,18 +1974,19 @@ device name,device type,product id,shortname,fullname,type [options...] \| (min/ "Logano GB125/KB195i, Logamatic MC110",boiler,133,maintenancedate,next maintenance date,string (>=0<=0), ,true,sensor.boiler_next_maintenance_date,sensor.boiler_maintenancedate,6,0,1,72,6 "Logano GB125/KB195i, Logamatic MC110",boiler,133,emergencyops,emergency operation,boolean (>=0<=0), ,true,switch.boiler_emergency_operation,switch.boiler_emergencyops,6,0,1,78,1 "Logano GB125/KB195i, Logamatic MC110",boiler,133,emergencytemp,emergency temperature,uint8 (>=15<=70),C,true,number.boiler_emergency_temperature,number.boiler_emergencytemp,6,0,1,79,1 -"Logano GB125/KB195i, Logamatic MC110",boiler,133,pc0flow,Flow PC0,int16,l/h,false,sensor.boiler_Flow_PC0,sensor.boiler_pc0flow,6,0,1,80,1 -"Logano GB125/KB195i, Logamatic MC110",boiler,133,pc1flow,Flow PC1,int16,l/h,false,sensor.boiler_Flow_PC1,sensor.boiler_pc1flow,6,0,1,81,1 -"Logano GB125/KB195i, Logamatic MC110",boiler,133,pc1on,PC1,boolean, ,false,binary_sensor.boiler_PC1,binary_sensor.boiler_pc1on,6,0,1,82,1 -"Logano GB125/KB195i, Logamatic MC110",boiler,133,pc1rate,PC1 rate,uint8,%,false,sensor.boiler_PC1_rate,sensor.boiler_pc1rate,6,0,1,83,1 -"Logano GB125/KB195i, Logamatic MC110",boiler,133,pumpkickhour,pump kick hour,uint8 (>=0<=23),hours,true,number.boiler_pump_kick_hour,number.boiler_pumpkickhour,6,0,1,84,1 -"Logano GB125/KB195i, Logamatic MC110",boiler,133,pumpkickday,pump kick day,enum [mo\|tu\|we\|th\|fr\|sa\|su\|all] (>=0<=0), ,true,select.boiler_pump_kick_day,select.boiler_pumpkickday,6,0,1,85,1 -"Logano GB125/KB195i, Logamatic MC110",boiler,133,pumpkickdelay,pump kick delay,uint16 (>=0<=32767),minutes,true,number.boiler_pump_kick_delay,number.boiler_pumpkickdelay,6,0,1,86,1 -"Logano GB125/KB195i, Logamatic MC110",boiler,133,meterheat,meter heating,uint24,kWh,false,sensor.boiler_meter_heating,sensor.boiler_meterheat,6,0,1/10,100,2 +"Logano GB125/KB195i, Logamatic MC110",boiler,133,pc0lpm,Flow PC0,uint16,l/min,false,sensor.boiler_Flow_PC0,sensor.boiler_pc0lpm,6,0,1/10,80,1 +"Logano GB125/KB195i, Logamatic MC110",boiler,133,pc0flow,Flow PC0,uint16,l/h,false,sensor.boiler_Flow_PC0,sensor.boiler_pc0flow,6,0,1,81,1 +"Logano GB125/KB195i, Logamatic MC110",boiler,133,pc1flow,Flow PC1,uint16,l/h,false,sensor.boiler_Flow_PC1,sensor.boiler_pc1flow,6,0,1,82,1 +"Logano GB125/KB195i, Logamatic MC110",boiler,133,pc1on,PC1,boolean, ,false,binary_sensor.boiler_PC1,binary_sensor.boiler_pc1on,6,0,1,83,1 +"Logano GB125/KB195i, Logamatic MC110",boiler,133,pc1rate,PC1 rate,uint8,%,false,sensor.boiler_PC1_rate,sensor.boiler_pc1rate,6,0,1,84,1 +"Logano GB125/KB195i, Logamatic MC110",boiler,133,pumpkickhour,pump kick hour,uint8 (>=0<=23),hours,true,number.boiler_pump_kick_hour,number.boiler_pumpkickhour,6,0,1,85,1 +"Logano GB125/KB195i, Logamatic MC110",boiler,133,pumpkickday,pump kick day,enum [mo\|tu\|we\|th\|fr\|sa\|su\|all] (>=0<=0), ,true,select.boiler_pump_kick_day,select.boiler_pumpkickday,6,0,1,86,1 +"Logano GB125/KB195i, Logamatic MC110",boiler,133,pumpkickdelay,pump kick delay,uint16 (>=0<=32767),minutes,true,number.boiler_pump_kick_delay,number.boiler_pumpkickdelay,6,0,1,87,1 +"Logano GB125/KB195i, Logamatic MC110",boiler,133,meterheat,meter heating,uint24,kWh,false,sensor.boiler_meter_heating,sensor.boiler_meterheat,6,0,1/10,101,2 "Logano GB125/KB195i, Logamatic MC110",boiler,133,dhw.meter,meter,uint24,kWh,false,sensor.boiler_dhw_meter,sensor.boiler_dhw_meter,6,9,1/10,2,2 -"Logano GB125/KB195i, Logamatic MC110",boiler,133,gasmeterheat,gas meter heating,uint24,kWh,false,sensor.boiler_gas_meter_heating,sensor.boiler_gasmeterheat,6,0,1/10,275,2 +"Logano GB125/KB195i, Logamatic MC110",boiler,133,gasmeterheat,gas meter heating,uint24,kWh,false,sensor.boiler_gas_meter_heating,sensor.boiler_gasmeterheat,6,0,1/10,276,2 "Logano GB125/KB195i, Logamatic MC110",boiler,133,dhw.gasmeter,gas meter,uint24,kWh,false,sensor.boiler_dhw_gas_meter,sensor.boiler_dhw_gasmeter,6,9,1/10,71,2 -"Logano GB125/KB195i, Logamatic MC110",boiler,133,nrgheat2,energy heating 2,uint24,kWh,false,sensor.boiler_energy_heating_2,sensor.boiler_nrgheat2,6,0,1/10,277,2 +"Logano GB125/KB195i, Logamatic MC110",boiler,133,nrgheat2,energy heating 2,uint24,kWh,false,sensor.boiler_energy_heating_2,sensor.boiler_nrgheat2,6,0,1/10,278,2 "Logano GB125/KB195i, Logamatic MC110",boiler,133,dhw.nrg2,energy 2,uint24,kWh,false,sensor.boiler_dhw_energy_2,sensor.boiler_dhw_nrg2,6,9,1/10,73,2 "Logano GB125/KB195i, Logamatic MC110",boiler,133,dhw.tapactivated,turn on/off,boolean (>=0<=0), ,true,switch.boiler_dhw_turn_on/off,switch.boiler_dhw_tapactivated,6,9,1,28,1 "Logano GB125/KB195i, Logamatic MC110",boiler,133,dhw.settemp,set temperature,uint8,C,false,sensor.boiler_dhw_set_temperature,sensor.boiler_dhw_settemp,6,9,1,29,1 @@ -2013,9 +2029,9 @@ device name,device type,product id,shortname,fullname,type [options...] \| (min/ "Logano GB125/KB195i, Logamatic MC110",boiler,133,dhw.dhwprio,dhw priority,boolean (>=0<=0), ,true,switch.boiler_dhw_dhw_priority,switch.boiler_dhw_dhwprio,6,9,1,66,1 "Logano GB125/KB195i, Logamatic MC110",boiler,133,dhw.starts,starts,uint24, ,false,sensor.boiler_dhw_starts,sensor.boiler_dhw_starts,6,9,1,67,2 "Logano GB125/KB195i, Logamatic MC110",boiler,133,dhw.workm,active time,time,minutes,false,sensor.boiler_dhw_active_time,sensor.boiler_dhw_workm,6,9,1,69,2 -"Logano GB125/KB195i, Logamatic MC110",boiler,133,nompower,nominal Power,uint8 (>=0<=0),kW,true,number.boiler_nominal_Power,number.boiler_nompower,6,0,1,279,1 -"Logano GB125/KB195i, Logamatic MC110",boiler,133,nrgtotal,total energy,uint24,kWh,false,sensor.boiler_total_energy,sensor.boiler_nrgtotal,6,0,1/100,88,2 -"Logano GB125/KB195i, Logamatic MC110",boiler,133,nrgheat,energy heating,uint24 (>=0<=10000000),kWh,true,number.boiler_energy_heating,number.boiler_nrgheat,6,0,1/100,90,2 +"Logano GB125/KB195i, Logamatic MC110",boiler,133,nompower,nominal Power,uint8 (>=0<=0),kW,true,number.boiler_nominal_Power,number.boiler_nompower,6,0,1,280,1 +"Logano GB125/KB195i, Logamatic MC110",boiler,133,nrgtotal,total energy,uint24,kWh,false,sensor.boiler_total_energy,sensor.boiler_nrgtotal,6,0,1/100,89,2 +"Logano GB125/KB195i, Logamatic MC110",boiler,133,nrgheat,energy heating,uint24 (>=0<=10000000),kWh,true,number.boiler_energy_heating,number.boiler_nrgheat,6,0,1/100,91,2 "Logano GB125/KB195i, Logamatic MC110",boiler,133,dhw.nrg,energy,uint24 (>=0<=10000000),kWh,true,number.boiler_dhw_energy,number.boiler_dhw_nrg,6,9,1/100,0,2 "Greenstar 30Ri Compact",boiler,154,reset,reset,cmd [-\|maintenance\|error\|history\|message\|hp error\|burner starts\|factory] (>=0<=0), ,true,sensor.boiler_reset,sensor.boiler_reset,6,0,1,0,1 "Greenstar 30Ri Compact",boiler,154,chimneysweeper,chimney sweeper,cmd [off\|on] (>=0<=0), ,true,sensor.boiler_chimney_sweeper,sensor.boiler_chimneysweeper,6,0,1,1,1 @@ -2031,28 +2047,28 @@ device name,device type,product id,shortname,fullname,type [options...] \| (min/ "Greenstar 30Ri Compact",boiler,154,syspress,system pressure,uint8,bar,false,sensor.boiler_system_pressure,sensor.boiler_syspress,6,0,1/10,11,1 "Greenstar 30Ri Compact",boiler,154,boiltemp,actual boiler temperature,uint16,C,false,sensor.boiler_actual_boiler_temperature,sensor.boiler_boiltemp,6,0,1/10,12,1 "Greenstar 30Ri Compact",boiler,154,headertemp,low loss header,uint16,C,false,sensor.boiler_low_loss_header,sensor.boiler_headertemp,6,0,1/10,13,1 -"Greenstar 30Ri Compact",boiler,154,exhausttemp,exhaust temperature,uint16,C,false,sensor.boiler_exhaust_temperature,sensor.boiler_exhausttemp,6,0,1/10,253,1 -"Greenstar 30Ri Compact",boiler,154,burngas,gas,boolean, ,false,binary_sensor.boiler_gas,binary_sensor.boiler_burngas,6,0,1,254,1 -"Greenstar 30Ri Compact",boiler,154,burngas2,gas stage 2,boolean, ,false,binary_sensor.boiler_gas_stage_2,binary_sensor.boiler_burngas2,6,0,1,255,1 -"Greenstar 30Ri Compact",boiler,154,flamecurr,flame current,uint16,µA,false,sensor.boiler_flame_current,sensor.boiler_flamecurr,6,0,1/10,256,1 -"Greenstar 30Ri Compact",boiler,154,fanwork,fan,boolean, ,false,binary_sensor.boiler_fan,binary_sensor.boiler_fanwork,6,0,1,257,1 -"Greenstar 30Ri Compact",boiler,154,ignwork,ignition,boolean, ,false,binary_sensor.boiler_ignition,binary_sensor.boiler_ignwork,6,0,1,258,1 -"Greenstar 30Ri Compact",boiler,154,oilpreheat,oil preheating,boolean, ,false,binary_sensor.boiler_oil_preheating,binary_sensor.boiler_oilpreheat,6,0,1,259,1 -"Greenstar 30Ri Compact",boiler,154,burnminpower,burner min power,uint8 (>=0<=0),%,true,number.boiler_burner_min_power,number.boiler_burnminpower,6,0,1,260,1 -"Greenstar 30Ri Compact",boiler,154,burnmaxpower,burner max power,uint8 (>=0<=254),%,true,number.boiler_burner_max_power,number.boiler_burnmaxpower,6,0,1,261,1 -"Greenstar 30Ri Compact",boiler,154,burnminperiod,burner min period,uint8 (>=0<=120),minutes,true,number.boiler_burner_min_period,number.boiler_burnminperiod,6,0,1,262,1 -"Greenstar 30Ri Compact",boiler,154,absburnpow,burner current power (absolute),uint8,%,false,sensor.boiler_burner_current_power_(absolute),sensor.boiler_absburnpow,6,0,1,263,1 -"Greenstar 30Ri Compact",boiler,154,heatblock,Heatblock temperature,uint16,C,false,sensor.boiler_Heatblock_temperature,sensor.boiler_heatblock,6,0,1/10,264,1 -"Greenstar 30Ri Compact",boiler,154,boilhyston,hysteresis on temperature,int8 (>=-20<=0),C,true,number.boiler_hysteresis_on_temperature,number.boiler_boilhyston,6,0,1,265,1 -"Greenstar 30Ri Compact",boiler,154,boilhystoff,hysteresis off temperature,int8 (>=0<=20),C,true,number.boiler_hysteresis_off_temperature,number.boiler_boilhystoff,6,0,1,266,1 -"Greenstar 30Ri Compact",boiler,154,boil2hyston,hysteresis stage 2 on temperature,int8 (>=-20<=0),C,true,number.boiler_hysteresis_stage_2_on_temperature,number.boiler_boil2hyston,6,0,1,267,1 -"Greenstar 30Ri Compact",boiler,154,boil2hystoff,hysteresis stage 2 off temperature,int8 (>=0<=20),C,true,number.boiler_hysteresis_stage_2_off_temperature,number.boiler_boil2hystoff,6,0,1,268,1 -"Greenstar 30Ri Compact",boiler,154,curveon,heatingcurve on,boolean (>=0<=0), ,true,switch.boiler_heatingcurve_on,switch.boiler_curveon,6,0,1,269,1 -"Greenstar 30Ri Compact",boiler,154,curvebase,heatingcurve base,uint8 (>=20<=90),C,true,number.boiler_heatingcurve_base,number.boiler_curvebase,6,0,1,270,1 -"Greenstar 30Ri Compact",boiler,154,curveend,heatingcurve end,uint8 (>=20<=90),C,true,number.boiler_heatingcurve_end,number.boiler_curveend,6,0,1,271,1 -"Greenstar 30Ri Compact",boiler,154,summertemp,summer temperature,uint8 (>=0<=45),C,true,number.boiler_summer_temperature,number.boiler_summertemp,6,0,1,272,1 -"Greenstar 30Ri Compact",boiler,154,nofrostmode,nofrost mode,boolean (>=0<=0), ,true,switch.boiler_nofrost_mode,switch.boiler_nofrostmode,6,0,1,273,1 -"Greenstar 30Ri Compact",boiler,154,nofrosttemp,nofrost temperature,uint8 (>=0<=10),C,true,number.boiler_nofrost_temperature,number.boiler_nofrosttemp,6,0,1,274,1 +"Greenstar 30Ri Compact",boiler,154,exhausttemp,exhaust temperature,uint16,C,false,sensor.boiler_exhaust_temperature,sensor.boiler_exhausttemp,6,0,1/10,254,1 +"Greenstar 30Ri Compact",boiler,154,burngas,gas,boolean, ,false,binary_sensor.boiler_gas,binary_sensor.boiler_burngas,6,0,1,255,1 +"Greenstar 30Ri Compact",boiler,154,burngas2,gas stage 2,boolean, ,false,binary_sensor.boiler_gas_stage_2,binary_sensor.boiler_burngas2,6,0,1,256,1 +"Greenstar 30Ri Compact",boiler,154,flamecurr,flame current,uint16,µA,false,sensor.boiler_flame_current,sensor.boiler_flamecurr,6,0,1/10,257,1 +"Greenstar 30Ri Compact",boiler,154,fanwork,fan,boolean, ,false,binary_sensor.boiler_fan,binary_sensor.boiler_fanwork,6,0,1,258,1 +"Greenstar 30Ri Compact",boiler,154,ignwork,ignition,boolean, ,false,binary_sensor.boiler_ignition,binary_sensor.boiler_ignwork,6,0,1,259,1 +"Greenstar 30Ri Compact",boiler,154,oilpreheat,oil preheating,boolean, ,false,binary_sensor.boiler_oil_preheating,binary_sensor.boiler_oilpreheat,6,0,1,260,1 +"Greenstar 30Ri Compact",boiler,154,burnminpower,burner min power,uint8 (>=0<=0),%,true,number.boiler_burner_min_power,number.boiler_burnminpower,6,0,1,261,1 +"Greenstar 30Ri Compact",boiler,154,burnmaxpower,burner max power,uint8 (>=0<=254),%,true,number.boiler_burner_max_power,number.boiler_burnmaxpower,6,0,1,262,1 +"Greenstar 30Ri Compact",boiler,154,burnminperiod,burner min period,uint8 (>=0<=120),minutes,true,number.boiler_burner_min_period,number.boiler_burnminperiod,6,0,1,263,1 +"Greenstar 30Ri Compact",boiler,154,absburnpow,burner current power (absolute),uint8,%,false,sensor.boiler_burner_current_power_(absolute),sensor.boiler_absburnpow,6,0,1,264,1 +"Greenstar 30Ri Compact",boiler,154,heatblock,Heatblock temperature,uint16,C,false,sensor.boiler_Heatblock_temperature,sensor.boiler_heatblock,6,0,1/10,265,1 +"Greenstar 30Ri Compact",boiler,154,boilhyston,hysteresis on temperature,int8 (>=-20<=0),C,true,number.boiler_hysteresis_on_temperature,number.boiler_boilhyston,6,0,1,266,1 +"Greenstar 30Ri Compact",boiler,154,boilhystoff,hysteresis off temperature,int8 (>=0<=20),C,true,number.boiler_hysteresis_off_temperature,number.boiler_boilhystoff,6,0,1,267,1 +"Greenstar 30Ri Compact",boiler,154,boil2hyston,hysteresis stage 2 on temperature,int8 (>=-20<=0),C,true,number.boiler_hysteresis_stage_2_on_temperature,number.boiler_boil2hyston,6,0,1,268,1 +"Greenstar 30Ri Compact",boiler,154,boil2hystoff,hysteresis stage 2 off temperature,int8 (>=0<=20),C,true,number.boiler_hysteresis_stage_2_off_temperature,number.boiler_boil2hystoff,6,0,1,269,1 +"Greenstar 30Ri Compact",boiler,154,curveon,heatingcurve on,boolean (>=0<=0), ,true,switch.boiler_heatingcurve_on,switch.boiler_curveon,6,0,1,270,1 +"Greenstar 30Ri Compact",boiler,154,curvebase,heatingcurve base,uint8 (>=20<=90),C,true,number.boiler_heatingcurve_base,number.boiler_curvebase,6,0,1,271,1 +"Greenstar 30Ri Compact",boiler,154,curveend,heatingcurve end,uint8 (>=20<=90),C,true,number.boiler_heatingcurve_end,number.boiler_curveend,6,0,1,272,1 +"Greenstar 30Ri Compact",boiler,154,summertemp,summer temperature,uint8 (>=0<=45),C,true,number.boiler_summer_temperature,number.boiler_summertemp,6,0,1,273,1 +"Greenstar 30Ri Compact",boiler,154,nofrostmode,nofrost mode,boolean (>=0<=0), ,true,switch.boiler_nofrost_mode,switch.boiler_nofrostmode,6,0,1,274,1 +"Greenstar 30Ri Compact",boiler,154,nofrosttemp,nofrost temperature,uint8 (>=0<=10),C,true,number.boiler_nofrost_temperature,number.boiler_nofrosttemp,6,0,1,275,1 "Greenstar 30Ri Compact",boiler,154,heatingactivated,heating activated,boolean (>=0<=0), ,true,switch.boiler_heating_activated,switch.boiler_heatingactivated,6,0,1,14,1 "Greenstar 30Ri Compact",boiler,154,heatingtemp,heating temperature,uint8 (>=0<=90),C,true,number.boiler_heating_temperature,number.boiler_heatingtemp,6,0,1,15,1 "Greenstar 30Ri Compact",boiler,154,heatingpump,heating pump,boolean, ,false,binary_sensor.boiler_heating_pump,binary_sensor.boiler_heatingpump,6,0,1,16,1 @@ -2079,18 +2095,19 @@ device name,device type,product id,shortname,fullname,type [options...] \| (min/ "Greenstar 30Ri Compact",boiler,154,maintenancedate,next maintenance date,string (>=0<=0), ,true,sensor.boiler_next_maintenance_date,sensor.boiler_maintenancedate,6,0,1,72,6 "Greenstar 30Ri Compact",boiler,154,emergencyops,emergency operation,boolean (>=0<=0), ,true,switch.boiler_emergency_operation,switch.boiler_emergencyops,6,0,1,78,1 "Greenstar 30Ri Compact",boiler,154,emergencytemp,emergency temperature,uint8 (>=15<=70),C,true,number.boiler_emergency_temperature,number.boiler_emergencytemp,6,0,1,79,1 -"Greenstar 30Ri Compact",boiler,154,pc0flow,Flow PC0,int16,l/h,false,sensor.boiler_Flow_PC0,sensor.boiler_pc0flow,6,0,1,80,1 -"Greenstar 30Ri Compact",boiler,154,pc1flow,Flow PC1,int16,l/h,false,sensor.boiler_Flow_PC1,sensor.boiler_pc1flow,6,0,1,81,1 -"Greenstar 30Ri Compact",boiler,154,pc1on,PC1,boolean, ,false,binary_sensor.boiler_PC1,binary_sensor.boiler_pc1on,6,0,1,82,1 -"Greenstar 30Ri Compact",boiler,154,pc1rate,PC1 rate,uint8,%,false,sensor.boiler_PC1_rate,sensor.boiler_pc1rate,6,0,1,83,1 -"Greenstar 30Ri Compact",boiler,154,pumpkickhour,pump kick hour,uint8 (>=0<=23),hours,true,number.boiler_pump_kick_hour,number.boiler_pumpkickhour,6,0,1,84,1 -"Greenstar 30Ri Compact",boiler,154,pumpkickday,pump kick day,enum [mo\|tu\|we\|th\|fr\|sa\|su\|all] (>=0<=0), ,true,select.boiler_pump_kick_day,select.boiler_pumpkickday,6,0,1,85,1 -"Greenstar 30Ri Compact",boiler,154,pumpkickdelay,pump kick delay,uint16 (>=0<=32767),minutes,true,number.boiler_pump_kick_delay,number.boiler_pumpkickdelay,6,0,1,86,1 -"Greenstar 30Ri Compact",boiler,154,meterheat,meter heating,uint24,kWh,false,sensor.boiler_meter_heating,sensor.boiler_meterheat,6,0,1/10,100,2 +"Greenstar 30Ri Compact",boiler,154,pc0lpm,Flow PC0,uint16,l/min,false,sensor.boiler_Flow_PC0,sensor.boiler_pc0lpm,6,0,1/10,80,1 +"Greenstar 30Ri Compact",boiler,154,pc0flow,Flow PC0,uint16,l/h,false,sensor.boiler_Flow_PC0,sensor.boiler_pc0flow,6,0,1,81,1 +"Greenstar 30Ri Compact",boiler,154,pc1flow,Flow PC1,uint16,l/h,false,sensor.boiler_Flow_PC1,sensor.boiler_pc1flow,6,0,1,82,1 +"Greenstar 30Ri Compact",boiler,154,pc1on,PC1,boolean, ,false,binary_sensor.boiler_PC1,binary_sensor.boiler_pc1on,6,0,1,83,1 +"Greenstar 30Ri Compact",boiler,154,pc1rate,PC1 rate,uint8,%,false,sensor.boiler_PC1_rate,sensor.boiler_pc1rate,6,0,1,84,1 +"Greenstar 30Ri Compact",boiler,154,pumpkickhour,pump kick hour,uint8 (>=0<=23),hours,true,number.boiler_pump_kick_hour,number.boiler_pumpkickhour,6,0,1,85,1 +"Greenstar 30Ri Compact",boiler,154,pumpkickday,pump kick day,enum [mo\|tu\|we\|th\|fr\|sa\|su\|all] (>=0<=0), ,true,select.boiler_pump_kick_day,select.boiler_pumpkickday,6,0,1,86,1 +"Greenstar 30Ri Compact",boiler,154,pumpkickdelay,pump kick delay,uint16 (>=0<=32767),minutes,true,number.boiler_pump_kick_delay,number.boiler_pumpkickdelay,6,0,1,87,1 +"Greenstar 30Ri Compact",boiler,154,meterheat,meter heating,uint24,kWh,false,sensor.boiler_meter_heating,sensor.boiler_meterheat,6,0,1/10,101,2 "Greenstar 30Ri Compact",boiler,154,dhw.meter,meter,uint24,kWh,false,sensor.boiler_dhw_meter,sensor.boiler_dhw_meter,6,9,1/10,2,2 -"Greenstar 30Ri Compact",boiler,154,gasmeterheat,gas meter heating,uint24,kWh,false,sensor.boiler_gas_meter_heating,sensor.boiler_gasmeterheat,6,0,1/10,275,2 +"Greenstar 30Ri Compact",boiler,154,gasmeterheat,gas meter heating,uint24,kWh,false,sensor.boiler_gas_meter_heating,sensor.boiler_gasmeterheat,6,0,1/10,276,2 "Greenstar 30Ri Compact",boiler,154,dhw.gasmeter,gas meter,uint24,kWh,false,sensor.boiler_dhw_gas_meter,sensor.boiler_dhw_gasmeter,6,9,1/10,71,2 -"Greenstar 30Ri Compact",boiler,154,nrgheat2,energy heating 2,uint24,kWh,false,sensor.boiler_energy_heating_2,sensor.boiler_nrgheat2,6,0,1/10,277,2 +"Greenstar 30Ri Compact",boiler,154,nrgheat2,energy heating 2,uint24,kWh,false,sensor.boiler_energy_heating_2,sensor.boiler_nrgheat2,6,0,1/10,278,2 "Greenstar 30Ri Compact",boiler,154,dhw.nrg2,energy 2,uint24,kWh,false,sensor.boiler_dhw_energy_2,sensor.boiler_dhw_nrg2,6,9,1/10,73,2 "Greenstar 30Ri Compact",boiler,154,dhw.tapactivated,turn on/off,boolean (>=0<=0), ,true,switch.boiler_dhw_turn_on/off,switch.boiler_dhw_tapactivated,6,9,1,28,1 "Greenstar 30Ri Compact",boiler,154,dhw.settemp,set temperature,uint8,C,false,sensor.boiler_dhw_set_temperature,sensor.boiler_dhw_settemp,6,9,1,29,1 @@ -2133,9 +2150,9 @@ device name,device type,product id,shortname,fullname,type [options...] \| (min/ "Greenstar 30Ri Compact",boiler,154,dhw.dhwprio,dhw priority,boolean (>=0<=0), ,true,switch.boiler_dhw_dhw_priority,switch.boiler_dhw_dhwprio,6,9,1,66,1 "Greenstar 30Ri Compact",boiler,154,dhw.starts,starts,uint24, ,false,sensor.boiler_dhw_starts,sensor.boiler_dhw_starts,6,9,1,67,2 "Greenstar 30Ri Compact",boiler,154,dhw.workm,active time,time,minutes,false,sensor.boiler_dhw_active_time,sensor.boiler_dhw_workm,6,9,1,69,2 -"Greenstar 30Ri Compact",boiler,154,nompower,nominal Power,uint8 (>=0<=0),kW,true,number.boiler_nominal_Power,number.boiler_nompower,6,0,1,279,1 -"Greenstar 30Ri Compact",boiler,154,nrgtotal,total energy,uint24,kWh,false,sensor.boiler_total_energy,sensor.boiler_nrgtotal,6,0,1/100,88,2 -"Greenstar 30Ri Compact",boiler,154,nrgheat,energy heating,uint24 (>=0<=10000000),kWh,true,number.boiler_energy_heating,number.boiler_nrgheat,6,0,1/100,90,2 +"Greenstar 30Ri Compact",boiler,154,nompower,nominal Power,uint8 (>=0<=0),kW,true,number.boiler_nominal_Power,number.boiler_nompower,6,0,1,280,1 +"Greenstar 30Ri Compact",boiler,154,nrgtotal,total energy,uint24,kWh,false,sensor.boiler_total_energy,sensor.boiler_nrgtotal,6,0,1/100,89,2 +"Greenstar 30Ri Compact",boiler,154,nrgheat,energy heating,uint24 (>=0<=10000000),kWh,true,number.boiler_energy_heating,number.boiler_nrgheat,6,0,1/100,91,2 "Greenstar 30Ri Compact",boiler,154,dhw.nrg,energy,uint24 (>=0<=10000000),kWh,true,number.boiler_dhw_energy,number.boiler_dhw_nrg,6,9,1/100,0,2 "Suprapur-o",boiler,155,reset,reset,cmd [-\|maintenance\|error\|history\|message\|hp error\|burner starts\|factory] (>=0<=0), ,true,sensor.boiler_reset,sensor.boiler_reset,6,0,1,0,1 "Suprapur-o",boiler,155,chimneysweeper,chimney sweeper,cmd [off\|on] (>=0<=0), ,true,sensor.boiler_chimney_sweeper,sensor.boiler_chimneysweeper,6,0,1,1,1 @@ -2151,28 +2168,28 @@ device name,device type,product id,shortname,fullname,type [options...] \| (min/ "Suprapur-o",boiler,155,syspress,system pressure,uint8,bar,false,sensor.boiler_system_pressure,sensor.boiler_syspress,6,0,1/10,11,1 "Suprapur-o",boiler,155,boiltemp,actual boiler temperature,uint16,C,false,sensor.boiler_actual_boiler_temperature,sensor.boiler_boiltemp,6,0,1/10,12,1 "Suprapur-o",boiler,155,headertemp,low loss header,uint16,C,false,sensor.boiler_low_loss_header,sensor.boiler_headertemp,6,0,1/10,13,1 -"Suprapur-o",boiler,155,exhausttemp,exhaust temperature,uint16,C,false,sensor.boiler_exhaust_temperature,sensor.boiler_exhausttemp,6,0,1/10,253,1 -"Suprapur-o",boiler,155,burngas,gas,boolean, ,false,binary_sensor.boiler_gas,binary_sensor.boiler_burngas,6,0,1,254,1 -"Suprapur-o",boiler,155,burngas2,gas stage 2,boolean, ,false,binary_sensor.boiler_gas_stage_2,binary_sensor.boiler_burngas2,6,0,1,255,1 -"Suprapur-o",boiler,155,flamecurr,flame current,uint16,µA,false,sensor.boiler_flame_current,sensor.boiler_flamecurr,6,0,1/10,256,1 -"Suprapur-o",boiler,155,fanwork,fan,boolean, ,false,binary_sensor.boiler_fan,binary_sensor.boiler_fanwork,6,0,1,257,1 -"Suprapur-o",boiler,155,ignwork,ignition,boolean, ,false,binary_sensor.boiler_ignition,binary_sensor.boiler_ignwork,6,0,1,258,1 -"Suprapur-o",boiler,155,oilpreheat,oil preheating,boolean, ,false,binary_sensor.boiler_oil_preheating,binary_sensor.boiler_oilpreheat,6,0,1,259,1 -"Suprapur-o",boiler,155,burnminpower,burner min power,uint8 (>=0<=0),%,true,number.boiler_burner_min_power,number.boiler_burnminpower,6,0,1,260,1 -"Suprapur-o",boiler,155,burnmaxpower,burner max power,uint8 (>=0<=254),%,true,number.boiler_burner_max_power,number.boiler_burnmaxpower,6,0,1,261,1 -"Suprapur-o",boiler,155,burnminperiod,burner min period,uint8 (>=0<=120),minutes,true,number.boiler_burner_min_period,number.boiler_burnminperiod,6,0,1,262,1 -"Suprapur-o",boiler,155,absburnpow,burner current power (absolute),uint8,%,false,sensor.boiler_burner_current_power_(absolute),sensor.boiler_absburnpow,6,0,1,263,1 -"Suprapur-o",boiler,155,heatblock,Heatblock temperature,uint16,C,false,sensor.boiler_Heatblock_temperature,sensor.boiler_heatblock,6,0,1/10,264,1 -"Suprapur-o",boiler,155,boilhyston,hysteresis on temperature,int8 (>=-20<=0),C,true,number.boiler_hysteresis_on_temperature,number.boiler_boilhyston,6,0,1,265,1 -"Suprapur-o",boiler,155,boilhystoff,hysteresis off temperature,int8 (>=0<=20),C,true,number.boiler_hysteresis_off_temperature,number.boiler_boilhystoff,6,0,1,266,1 -"Suprapur-o",boiler,155,boil2hyston,hysteresis stage 2 on temperature,int8 (>=-20<=0),C,true,number.boiler_hysteresis_stage_2_on_temperature,number.boiler_boil2hyston,6,0,1,267,1 -"Suprapur-o",boiler,155,boil2hystoff,hysteresis stage 2 off temperature,int8 (>=0<=20),C,true,number.boiler_hysteresis_stage_2_off_temperature,number.boiler_boil2hystoff,6,0,1,268,1 -"Suprapur-o",boiler,155,curveon,heatingcurve on,boolean (>=0<=0), ,true,switch.boiler_heatingcurve_on,switch.boiler_curveon,6,0,1,269,1 -"Suprapur-o",boiler,155,curvebase,heatingcurve base,uint8 (>=20<=90),C,true,number.boiler_heatingcurve_base,number.boiler_curvebase,6,0,1,270,1 -"Suprapur-o",boiler,155,curveend,heatingcurve end,uint8 (>=20<=90),C,true,number.boiler_heatingcurve_end,number.boiler_curveend,6,0,1,271,1 -"Suprapur-o",boiler,155,summertemp,summer temperature,uint8 (>=0<=45),C,true,number.boiler_summer_temperature,number.boiler_summertemp,6,0,1,272,1 -"Suprapur-o",boiler,155,nofrostmode,nofrost mode,boolean (>=0<=0), ,true,switch.boiler_nofrost_mode,switch.boiler_nofrostmode,6,0,1,273,1 -"Suprapur-o",boiler,155,nofrosttemp,nofrost temperature,uint8 (>=0<=10),C,true,number.boiler_nofrost_temperature,number.boiler_nofrosttemp,6,0,1,274,1 +"Suprapur-o",boiler,155,exhausttemp,exhaust temperature,uint16,C,false,sensor.boiler_exhaust_temperature,sensor.boiler_exhausttemp,6,0,1/10,254,1 +"Suprapur-o",boiler,155,burngas,gas,boolean, ,false,binary_sensor.boiler_gas,binary_sensor.boiler_burngas,6,0,1,255,1 +"Suprapur-o",boiler,155,burngas2,gas stage 2,boolean, ,false,binary_sensor.boiler_gas_stage_2,binary_sensor.boiler_burngas2,6,0,1,256,1 +"Suprapur-o",boiler,155,flamecurr,flame current,uint16,µA,false,sensor.boiler_flame_current,sensor.boiler_flamecurr,6,0,1/10,257,1 +"Suprapur-o",boiler,155,fanwork,fan,boolean, ,false,binary_sensor.boiler_fan,binary_sensor.boiler_fanwork,6,0,1,258,1 +"Suprapur-o",boiler,155,ignwork,ignition,boolean, ,false,binary_sensor.boiler_ignition,binary_sensor.boiler_ignwork,6,0,1,259,1 +"Suprapur-o",boiler,155,oilpreheat,oil preheating,boolean, ,false,binary_sensor.boiler_oil_preheating,binary_sensor.boiler_oilpreheat,6,0,1,260,1 +"Suprapur-o",boiler,155,burnminpower,burner min power,uint8 (>=0<=0),%,true,number.boiler_burner_min_power,number.boiler_burnminpower,6,0,1,261,1 +"Suprapur-o",boiler,155,burnmaxpower,burner max power,uint8 (>=0<=254),%,true,number.boiler_burner_max_power,number.boiler_burnmaxpower,6,0,1,262,1 +"Suprapur-o",boiler,155,burnminperiod,burner min period,uint8 (>=0<=120),minutes,true,number.boiler_burner_min_period,number.boiler_burnminperiod,6,0,1,263,1 +"Suprapur-o",boiler,155,absburnpow,burner current power (absolute),uint8,%,false,sensor.boiler_burner_current_power_(absolute),sensor.boiler_absburnpow,6,0,1,264,1 +"Suprapur-o",boiler,155,heatblock,Heatblock temperature,uint16,C,false,sensor.boiler_Heatblock_temperature,sensor.boiler_heatblock,6,0,1/10,265,1 +"Suprapur-o",boiler,155,boilhyston,hysteresis on temperature,int8 (>=-20<=0),C,true,number.boiler_hysteresis_on_temperature,number.boiler_boilhyston,6,0,1,266,1 +"Suprapur-o",boiler,155,boilhystoff,hysteresis off temperature,int8 (>=0<=20),C,true,number.boiler_hysteresis_off_temperature,number.boiler_boilhystoff,6,0,1,267,1 +"Suprapur-o",boiler,155,boil2hyston,hysteresis stage 2 on temperature,int8 (>=-20<=0),C,true,number.boiler_hysteresis_stage_2_on_temperature,number.boiler_boil2hyston,6,0,1,268,1 +"Suprapur-o",boiler,155,boil2hystoff,hysteresis stage 2 off temperature,int8 (>=0<=20),C,true,number.boiler_hysteresis_stage_2_off_temperature,number.boiler_boil2hystoff,6,0,1,269,1 +"Suprapur-o",boiler,155,curveon,heatingcurve on,boolean (>=0<=0), ,true,switch.boiler_heatingcurve_on,switch.boiler_curveon,6,0,1,270,1 +"Suprapur-o",boiler,155,curvebase,heatingcurve base,uint8 (>=20<=90),C,true,number.boiler_heatingcurve_base,number.boiler_curvebase,6,0,1,271,1 +"Suprapur-o",boiler,155,curveend,heatingcurve end,uint8 (>=20<=90),C,true,number.boiler_heatingcurve_end,number.boiler_curveend,6,0,1,272,1 +"Suprapur-o",boiler,155,summertemp,summer temperature,uint8 (>=0<=45),C,true,number.boiler_summer_temperature,number.boiler_summertemp,6,0,1,273,1 +"Suprapur-o",boiler,155,nofrostmode,nofrost mode,boolean (>=0<=0), ,true,switch.boiler_nofrost_mode,switch.boiler_nofrostmode,6,0,1,274,1 +"Suprapur-o",boiler,155,nofrosttemp,nofrost temperature,uint8 (>=0<=10),C,true,number.boiler_nofrost_temperature,number.boiler_nofrosttemp,6,0,1,275,1 "Suprapur-o",boiler,155,heatingactivated,heating activated,boolean (>=0<=0), ,true,switch.boiler_heating_activated,switch.boiler_heatingactivated,6,0,1,14,1 "Suprapur-o",boiler,155,heatingtemp,heating temperature,uint8 (>=0<=90),C,true,number.boiler_heating_temperature,number.boiler_heatingtemp,6,0,1,15,1 "Suprapur-o",boiler,155,heatingpump,heating pump,boolean, ,false,binary_sensor.boiler_heating_pump,binary_sensor.boiler_heatingpump,6,0,1,16,1 @@ -2199,18 +2216,19 @@ device name,device type,product id,shortname,fullname,type [options...] \| (min/ "Suprapur-o",boiler,155,maintenancedate,next maintenance date,string (>=0<=0), ,true,sensor.boiler_next_maintenance_date,sensor.boiler_maintenancedate,6,0,1,72,6 "Suprapur-o",boiler,155,emergencyops,emergency operation,boolean (>=0<=0), ,true,switch.boiler_emergency_operation,switch.boiler_emergencyops,6,0,1,78,1 "Suprapur-o",boiler,155,emergencytemp,emergency temperature,uint8 (>=15<=70),C,true,number.boiler_emergency_temperature,number.boiler_emergencytemp,6,0,1,79,1 -"Suprapur-o",boiler,155,pc0flow,Flow PC0,int16,l/h,false,sensor.boiler_Flow_PC0,sensor.boiler_pc0flow,6,0,1,80,1 -"Suprapur-o",boiler,155,pc1flow,Flow PC1,int16,l/h,false,sensor.boiler_Flow_PC1,sensor.boiler_pc1flow,6,0,1,81,1 -"Suprapur-o",boiler,155,pc1on,PC1,boolean, ,false,binary_sensor.boiler_PC1,binary_sensor.boiler_pc1on,6,0,1,82,1 -"Suprapur-o",boiler,155,pc1rate,PC1 rate,uint8,%,false,sensor.boiler_PC1_rate,sensor.boiler_pc1rate,6,0,1,83,1 -"Suprapur-o",boiler,155,pumpkickhour,pump kick hour,uint8 (>=0<=23),hours,true,number.boiler_pump_kick_hour,number.boiler_pumpkickhour,6,0,1,84,1 -"Suprapur-o",boiler,155,pumpkickday,pump kick day,enum [mo\|tu\|we\|th\|fr\|sa\|su\|all] (>=0<=0), ,true,select.boiler_pump_kick_day,select.boiler_pumpkickday,6,0,1,85,1 -"Suprapur-o",boiler,155,pumpkickdelay,pump kick delay,uint16 (>=0<=32767),minutes,true,number.boiler_pump_kick_delay,number.boiler_pumpkickdelay,6,0,1,86,1 -"Suprapur-o",boiler,155,meterheat,meter heating,uint24,kWh,false,sensor.boiler_meter_heating,sensor.boiler_meterheat,6,0,1/10,100,2 +"Suprapur-o",boiler,155,pc0lpm,Flow PC0,uint16,l/min,false,sensor.boiler_Flow_PC0,sensor.boiler_pc0lpm,6,0,1/10,80,1 +"Suprapur-o",boiler,155,pc0flow,Flow PC0,uint16,l/h,false,sensor.boiler_Flow_PC0,sensor.boiler_pc0flow,6,0,1,81,1 +"Suprapur-o",boiler,155,pc1flow,Flow PC1,uint16,l/h,false,sensor.boiler_Flow_PC1,sensor.boiler_pc1flow,6,0,1,82,1 +"Suprapur-o",boiler,155,pc1on,PC1,boolean, ,false,binary_sensor.boiler_PC1,binary_sensor.boiler_pc1on,6,0,1,83,1 +"Suprapur-o",boiler,155,pc1rate,PC1 rate,uint8,%,false,sensor.boiler_PC1_rate,sensor.boiler_pc1rate,6,0,1,84,1 +"Suprapur-o",boiler,155,pumpkickhour,pump kick hour,uint8 (>=0<=23),hours,true,number.boiler_pump_kick_hour,number.boiler_pumpkickhour,6,0,1,85,1 +"Suprapur-o",boiler,155,pumpkickday,pump kick day,enum [mo\|tu\|we\|th\|fr\|sa\|su\|all] (>=0<=0), ,true,select.boiler_pump_kick_day,select.boiler_pumpkickday,6,0,1,86,1 +"Suprapur-o",boiler,155,pumpkickdelay,pump kick delay,uint16 (>=0<=32767),minutes,true,number.boiler_pump_kick_delay,number.boiler_pumpkickdelay,6,0,1,87,1 +"Suprapur-o",boiler,155,meterheat,meter heating,uint24,kWh,false,sensor.boiler_meter_heating,sensor.boiler_meterheat,6,0,1/10,101,2 "Suprapur-o",boiler,155,dhw.meter,meter,uint24,kWh,false,sensor.boiler_dhw_meter,sensor.boiler_dhw_meter,6,9,1/10,2,2 -"Suprapur-o",boiler,155,gasmeterheat,gas meter heating,uint24,kWh,false,sensor.boiler_gas_meter_heating,sensor.boiler_gasmeterheat,6,0,1/10,275,2 +"Suprapur-o",boiler,155,gasmeterheat,gas meter heating,uint24,kWh,false,sensor.boiler_gas_meter_heating,sensor.boiler_gasmeterheat,6,0,1/10,276,2 "Suprapur-o",boiler,155,dhw.gasmeter,gas meter,uint24,kWh,false,sensor.boiler_dhw_gas_meter,sensor.boiler_dhw_gasmeter,6,9,1/10,71,2 -"Suprapur-o",boiler,155,nrgheat2,energy heating 2,uint24,kWh,false,sensor.boiler_energy_heating_2,sensor.boiler_nrgheat2,6,0,1/10,277,2 +"Suprapur-o",boiler,155,nrgheat2,energy heating 2,uint24,kWh,false,sensor.boiler_energy_heating_2,sensor.boiler_nrgheat2,6,0,1/10,278,2 "Suprapur-o",boiler,155,dhw.nrg2,energy 2,uint24,kWh,false,sensor.boiler_dhw_energy_2,sensor.boiler_dhw_nrg2,6,9,1/10,73,2 "Suprapur-o",boiler,155,dhw.tapactivated,turn on/off,boolean (>=0<=0), ,true,switch.boiler_dhw_turn_on/off,switch.boiler_dhw_tapactivated,6,9,1,28,1 "Suprapur-o",boiler,155,dhw.settemp,set temperature,uint8,C,false,sensor.boiler_dhw_set_temperature,sensor.boiler_dhw_settemp,6,9,1,29,1 @@ -2253,9 +2271,9 @@ device name,device type,product id,shortname,fullname,type [options...] \| (min/ "Suprapur-o",boiler,155,dhw.dhwprio,dhw priority,boolean (>=0<=0), ,true,switch.boiler_dhw_dhw_priority,switch.boiler_dhw_dhwprio,6,9,1,66,1 "Suprapur-o",boiler,155,dhw.starts,starts,uint24, ,false,sensor.boiler_dhw_starts,sensor.boiler_dhw_starts,6,9,1,67,2 "Suprapur-o",boiler,155,dhw.workm,active time,time,minutes,false,sensor.boiler_dhw_active_time,sensor.boiler_dhw_workm,6,9,1,69,2 -"Suprapur-o",boiler,155,nompower,nominal Power,uint8 (>=0<=0),kW,true,number.boiler_nominal_Power,number.boiler_nompower,6,0,1,279,1 -"Suprapur-o",boiler,155,nrgtotal,total energy,uint24,kWh,false,sensor.boiler_total_energy,sensor.boiler_nrgtotal,6,0,1/100,88,2 -"Suprapur-o",boiler,155,nrgheat,energy heating,uint24 (>=0<=10000000),kWh,true,number.boiler_energy_heating,number.boiler_nrgheat,6,0,1/100,90,2 +"Suprapur-o",boiler,155,nompower,nominal Power,uint8 (>=0<=0),kW,true,number.boiler_nominal_Power,number.boiler_nompower,6,0,1,280,1 +"Suprapur-o",boiler,155,nrgtotal,total energy,uint24,kWh,false,sensor.boiler_total_energy,sensor.boiler_nrgtotal,6,0,1/100,89,2 +"Suprapur-o",boiler,155,nrgheat,energy heating,uint24 (>=0<=10000000),kWh,true,number.boiler_energy_heating,number.boiler_nrgheat,6,0,1/100,91,2 "Suprapur-o",boiler,155,dhw.nrg,energy,uint24 (>=0<=10000000),kWh,true,number.boiler_dhw_energy,number.boiler_dhw_nrg,6,9,1/100,0,2 "Cerapur Aero",boiler,167,reset,reset,cmd [-\|maintenance\|error\|history\|message\|hp error\|burner starts\|factory] (>=0<=0), ,true,sensor.boiler_reset,sensor.boiler_reset,6,0,1,0,1 "Cerapur Aero",boiler,167,chimneysweeper,chimney sweeper,cmd [off\|on] (>=0<=0), ,true,sensor.boiler_chimney_sweeper,sensor.boiler_chimneysweeper,6,0,1,1,1 @@ -2271,28 +2289,28 @@ device name,device type,product id,shortname,fullname,type [options...] \| (min/ "Cerapur Aero",boiler,167,syspress,system pressure,uint8,bar,false,sensor.boiler_system_pressure,sensor.boiler_syspress,6,0,1/10,11,1 "Cerapur Aero",boiler,167,boiltemp,actual boiler temperature,uint16,C,false,sensor.boiler_actual_boiler_temperature,sensor.boiler_boiltemp,6,0,1/10,12,1 "Cerapur Aero",boiler,167,headertemp,low loss header,uint16,C,false,sensor.boiler_low_loss_header,sensor.boiler_headertemp,6,0,1/10,13,1 -"Cerapur Aero",boiler,167,exhausttemp,exhaust temperature,uint16,C,false,sensor.boiler_exhaust_temperature,sensor.boiler_exhausttemp,6,0,1/10,253,1 -"Cerapur Aero",boiler,167,burngas,gas,boolean, ,false,binary_sensor.boiler_gas,binary_sensor.boiler_burngas,6,0,1,254,1 -"Cerapur Aero",boiler,167,burngas2,gas stage 2,boolean, ,false,binary_sensor.boiler_gas_stage_2,binary_sensor.boiler_burngas2,6,0,1,255,1 -"Cerapur Aero",boiler,167,flamecurr,flame current,uint16,µA,false,sensor.boiler_flame_current,sensor.boiler_flamecurr,6,0,1/10,256,1 -"Cerapur Aero",boiler,167,fanwork,fan,boolean, ,false,binary_sensor.boiler_fan,binary_sensor.boiler_fanwork,6,0,1,257,1 -"Cerapur Aero",boiler,167,ignwork,ignition,boolean, ,false,binary_sensor.boiler_ignition,binary_sensor.boiler_ignwork,6,0,1,258,1 -"Cerapur Aero",boiler,167,oilpreheat,oil preheating,boolean, ,false,binary_sensor.boiler_oil_preheating,binary_sensor.boiler_oilpreheat,6,0,1,259,1 -"Cerapur Aero",boiler,167,burnminpower,burner min power,uint8 (>=0<=0),%,true,number.boiler_burner_min_power,number.boiler_burnminpower,6,0,1,260,1 -"Cerapur Aero",boiler,167,burnmaxpower,burner max power,uint8 (>=0<=254),%,true,number.boiler_burner_max_power,number.boiler_burnmaxpower,6,0,1,261,1 -"Cerapur Aero",boiler,167,burnminperiod,burner min period,uint8 (>=0<=120),minutes,true,number.boiler_burner_min_period,number.boiler_burnminperiod,6,0,1,262,1 -"Cerapur Aero",boiler,167,absburnpow,burner current power (absolute),uint8,%,false,sensor.boiler_burner_current_power_(absolute),sensor.boiler_absburnpow,6,0,1,263,1 -"Cerapur Aero",boiler,167,heatblock,Heatblock temperature,uint16,C,false,sensor.boiler_Heatblock_temperature,sensor.boiler_heatblock,6,0,1/10,264,1 -"Cerapur Aero",boiler,167,boilhyston,hysteresis on temperature,int8 (>=-20<=0),C,true,number.boiler_hysteresis_on_temperature,number.boiler_boilhyston,6,0,1,265,1 -"Cerapur Aero",boiler,167,boilhystoff,hysteresis off temperature,int8 (>=0<=20),C,true,number.boiler_hysteresis_off_temperature,number.boiler_boilhystoff,6,0,1,266,1 -"Cerapur Aero",boiler,167,boil2hyston,hysteresis stage 2 on temperature,int8 (>=-20<=0),C,true,number.boiler_hysteresis_stage_2_on_temperature,number.boiler_boil2hyston,6,0,1,267,1 -"Cerapur Aero",boiler,167,boil2hystoff,hysteresis stage 2 off temperature,int8 (>=0<=20),C,true,number.boiler_hysteresis_stage_2_off_temperature,number.boiler_boil2hystoff,6,0,1,268,1 -"Cerapur Aero",boiler,167,curveon,heatingcurve on,boolean (>=0<=0), ,true,switch.boiler_heatingcurve_on,switch.boiler_curveon,6,0,1,269,1 -"Cerapur Aero",boiler,167,curvebase,heatingcurve base,uint8 (>=20<=90),C,true,number.boiler_heatingcurve_base,number.boiler_curvebase,6,0,1,270,1 -"Cerapur Aero",boiler,167,curveend,heatingcurve end,uint8 (>=20<=90),C,true,number.boiler_heatingcurve_end,number.boiler_curveend,6,0,1,271,1 -"Cerapur Aero",boiler,167,summertemp,summer temperature,uint8 (>=0<=45),C,true,number.boiler_summer_temperature,number.boiler_summertemp,6,0,1,272,1 -"Cerapur Aero",boiler,167,nofrostmode,nofrost mode,boolean (>=0<=0), ,true,switch.boiler_nofrost_mode,switch.boiler_nofrostmode,6,0,1,273,1 -"Cerapur Aero",boiler,167,nofrosttemp,nofrost temperature,uint8 (>=0<=10),C,true,number.boiler_nofrost_temperature,number.boiler_nofrosttemp,6,0,1,274,1 +"Cerapur Aero",boiler,167,exhausttemp,exhaust temperature,uint16,C,false,sensor.boiler_exhaust_temperature,sensor.boiler_exhausttemp,6,0,1/10,254,1 +"Cerapur Aero",boiler,167,burngas,gas,boolean, ,false,binary_sensor.boiler_gas,binary_sensor.boiler_burngas,6,0,1,255,1 +"Cerapur Aero",boiler,167,burngas2,gas stage 2,boolean, ,false,binary_sensor.boiler_gas_stage_2,binary_sensor.boiler_burngas2,6,0,1,256,1 +"Cerapur Aero",boiler,167,flamecurr,flame current,uint16,µA,false,sensor.boiler_flame_current,sensor.boiler_flamecurr,6,0,1/10,257,1 +"Cerapur Aero",boiler,167,fanwork,fan,boolean, ,false,binary_sensor.boiler_fan,binary_sensor.boiler_fanwork,6,0,1,258,1 +"Cerapur Aero",boiler,167,ignwork,ignition,boolean, ,false,binary_sensor.boiler_ignition,binary_sensor.boiler_ignwork,6,0,1,259,1 +"Cerapur Aero",boiler,167,oilpreheat,oil preheating,boolean, ,false,binary_sensor.boiler_oil_preheating,binary_sensor.boiler_oilpreheat,6,0,1,260,1 +"Cerapur Aero",boiler,167,burnminpower,burner min power,uint8 (>=0<=0),%,true,number.boiler_burner_min_power,number.boiler_burnminpower,6,0,1,261,1 +"Cerapur Aero",boiler,167,burnmaxpower,burner max power,uint8 (>=0<=254),%,true,number.boiler_burner_max_power,number.boiler_burnmaxpower,6,0,1,262,1 +"Cerapur Aero",boiler,167,burnminperiod,burner min period,uint8 (>=0<=120),minutes,true,number.boiler_burner_min_period,number.boiler_burnminperiod,6,0,1,263,1 +"Cerapur Aero",boiler,167,absburnpow,burner current power (absolute),uint8,%,false,sensor.boiler_burner_current_power_(absolute),sensor.boiler_absburnpow,6,0,1,264,1 +"Cerapur Aero",boiler,167,heatblock,Heatblock temperature,uint16,C,false,sensor.boiler_Heatblock_temperature,sensor.boiler_heatblock,6,0,1/10,265,1 +"Cerapur Aero",boiler,167,boilhyston,hysteresis on temperature,int8 (>=-20<=0),C,true,number.boiler_hysteresis_on_temperature,number.boiler_boilhyston,6,0,1,266,1 +"Cerapur Aero",boiler,167,boilhystoff,hysteresis off temperature,int8 (>=0<=20),C,true,number.boiler_hysteresis_off_temperature,number.boiler_boilhystoff,6,0,1,267,1 +"Cerapur Aero",boiler,167,boil2hyston,hysteresis stage 2 on temperature,int8 (>=-20<=0),C,true,number.boiler_hysteresis_stage_2_on_temperature,number.boiler_boil2hyston,6,0,1,268,1 +"Cerapur Aero",boiler,167,boil2hystoff,hysteresis stage 2 off temperature,int8 (>=0<=20),C,true,number.boiler_hysteresis_stage_2_off_temperature,number.boiler_boil2hystoff,6,0,1,269,1 +"Cerapur Aero",boiler,167,curveon,heatingcurve on,boolean (>=0<=0), ,true,switch.boiler_heatingcurve_on,switch.boiler_curveon,6,0,1,270,1 +"Cerapur Aero",boiler,167,curvebase,heatingcurve base,uint8 (>=20<=90),C,true,number.boiler_heatingcurve_base,number.boiler_curvebase,6,0,1,271,1 +"Cerapur Aero",boiler,167,curveend,heatingcurve end,uint8 (>=20<=90),C,true,number.boiler_heatingcurve_end,number.boiler_curveend,6,0,1,272,1 +"Cerapur Aero",boiler,167,summertemp,summer temperature,uint8 (>=0<=45),C,true,number.boiler_summer_temperature,number.boiler_summertemp,6,0,1,273,1 +"Cerapur Aero",boiler,167,nofrostmode,nofrost mode,boolean (>=0<=0), ,true,switch.boiler_nofrost_mode,switch.boiler_nofrostmode,6,0,1,274,1 +"Cerapur Aero",boiler,167,nofrosttemp,nofrost temperature,uint8 (>=0<=10),C,true,number.boiler_nofrost_temperature,number.boiler_nofrosttemp,6,0,1,275,1 "Cerapur Aero",boiler,167,heatingactivated,heating activated,boolean (>=0<=0), ,true,switch.boiler_heating_activated,switch.boiler_heatingactivated,6,0,1,14,1 "Cerapur Aero",boiler,167,heatingtemp,heating temperature,uint8 (>=0<=90),C,true,number.boiler_heating_temperature,number.boiler_heatingtemp,6,0,1,15,1 "Cerapur Aero",boiler,167,heatingpump,heating pump,boolean, ,false,binary_sensor.boiler_heating_pump,binary_sensor.boiler_heatingpump,6,0,1,16,1 @@ -2319,18 +2337,19 @@ device name,device type,product id,shortname,fullname,type [options...] \| (min/ "Cerapur Aero",boiler,167,maintenancedate,next maintenance date,string (>=0<=0), ,true,sensor.boiler_next_maintenance_date,sensor.boiler_maintenancedate,6,0,1,72,6 "Cerapur Aero",boiler,167,emergencyops,emergency operation,boolean (>=0<=0), ,true,switch.boiler_emergency_operation,switch.boiler_emergencyops,6,0,1,78,1 "Cerapur Aero",boiler,167,emergencytemp,emergency temperature,uint8 (>=15<=70),C,true,number.boiler_emergency_temperature,number.boiler_emergencytemp,6,0,1,79,1 -"Cerapur Aero",boiler,167,pc0flow,Flow PC0,int16,l/h,false,sensor.boiler_Flow_PC0,sensor.boiler_pc0flow,6,0,1,80,1 -"Cerapur Aero",boiler,167,pc1flow,Flow PC1,int16,l/h,false,sensor.boiler_Flow_PC1,sensor.boiler_pc1flow,6,0,1,81,1 -"Cerapur Aero",boiler,167,pc1on,PC1,boolean, ,false,binary_sensor.boiler_PC1,binary_sensor.boiler_pc1on,6,0,1,82,1 -"Cerapur Aero",boiler,167,pc1rate,PC1 rate,uint8,%,false,sensor.boiler_PC1_rate,sensor.boiler_pc1rate,6,0,1,83,1 -"Cerapur Aero",boiler,167,pumpkickhour,pump kick hour,uint8 (>=0<=23),hours,true,number.boiler_pump_kick_hour,number.boiler_pumpkickhour,6,0,1,84,1 -"Cerapur Aero",boiler,167,pumpkickday,pump kick day,enum [mo\|tu\|we\|th\|fr\|sa\|su\|all] (>=0<=0), ,true,select.boiler_pump_kick_day,select.boiler_pumpkickday,6,0,1,85,1 -"Cerapur Aero",boiler,167,pumpkickdelay,pump kick delay,uint16 (>=0<=32767),minutes,true,number.boiler_pump_kick_delay,number.boiler_pumpkickdelay,6,0,1,86,1 -"Cerapur Aero",boiler,167,meterheat,meter heating,uint24,kWh,false,sensor.boiler_meter_heating,sensor.boiler_meterheat,6,0,1/10,100,2 +"Cerapur Aero",boiler,167,pc0lpm,Flow PC0,uint16,l/min,false,sensor.boiler_Flow_PC0,sensor.boiler_pc0lpm,6,0,1/10,80,1 +"Cerapur Aero",boiler,167,pc0flow,Flow PC0,uint16,l/h,false,sensor.boiler_Flow_PC0,sensor.boiler_pc0flow,6,0,1,81,1 +"Cerapur Aero",boiler,167,pc1flow,Flow PC1,uint16,l/h,false,sensor.boiler_Flow_PC1,sensor.boiler_pc1flow,6,0,1,82,1 +"Cerapur Aero",boiler,167,pc1on,PC1,boolean, ,false,binary_sensor.boiler_PC1,binary_sensor.boiler_pc1on,6,0,1,83,1 +"Cerapur Aero",boiler,167,pc1rate,PC1 rate,uint8,%,false,sensor.boiler_PC1_rate,sensor.boiler_pc1rate,6,0,1,84,1 +"Cerapur Aero",boiler,167,pumpkickhour,pump kick hour,uint8 (>=0<=23),hours,true,number.boiler_pump_kick_hour,number.boiler_pumpkickhour,6,0,1,85,1 +"Cerapur Aero",boiler,167,pumpkickday,pump kick day,enum [mo\|tu\|we\|th\|fr\|sa\|su\|all] (>=0<=0), ,true,select.boiler_pump_kick_day,select.boiler_pumpkickday,6,0,1,86,1 +"Cerapur Aero",boiler,167,pumpkickdelay,pump kick delay,uint16 (>=0<=32767),minutes,true,number.boiler_pump_kick_delay,number.boiler_pumpkickdelay,6,0,1,87,1 +"Cerapur Aero",boiler,167,meterheat,meter heating,uint24,kWh,false,sensor.boiler_meter_heating,sensor.boiler_meterheat,6,0,1/10,101,2 "Cerapur Aero",boiler,167,dhw.meter,meter,uint24,kWh,false,sensor.boiler_dhw_meter,sensor.boiler_dhw_meter,6,9,1/10,2,2 -"Cerapur Aero",boiler,167,gasmeterheat,gas meter heating,uint24,kWh,false,sensor.boiler_gas_meter_heating,sensor.boiler_gasmeterheat,6,0,1/10,275,2 +"Cerapur Aero",boiler,167,gasmeterheat,gas meter heating,uint24,kWh,false,sensor.boiler_gas_meter_heating,sensor.boiler_gasmeterheat,6,0,1/10,276,2 "Cerapur Aero",boiler,167,dhw.gasmeter,gas meter,uint24,kWh,false,sensor.boiler_dhw_gas_meter,sensor.boiler_dhw_gasmeter,6,9,1/10,71,2 -"Cerapur Aero",boiler,167,nrgheat2,energy heating 2,uint24,kWh,false,sensor.boiler_energy_heating_2,sensor.boiler_nrgheat2,6,0,1/10,277,2 +"Cerapur Aero",boiler,167,nrgheat2,energy heating 2,uint24,kWh,false,sensor.boiler_energy_heating_2,sensor.boiler_nrgheat2,6,0,1/10,278,2 "Cerapur Aero",boiler,167,dhw.nrg2,energy 2,uint24,kWh,false,sensor.boiler_dhw_energy_2,sensor.boiler_dhw_nrg2,6,9,1/10,73,2 "Cerapur Aero",boiler,167,dhw.tapactivated,turn on/off,boolean (>=0<=0), ,true,switch.boiler_dhw_turn_on/off,switch.boiler_dhw_tapactivated,6,9,1,28,1 "Cerapur Aero",boiler,167,dhw.settemp,set temperature,uint8,C,false,sensor.boiler_dhw_set_temperature,sensor.boiler_dhw_settemp,6,9,1,29,1 @@ -2373,9 +2392,9 @@ device name,device type,product id,shortname,fullname,type [options...] \| (min/ "Cerapur Aero",boiler,167,dhw.dhwprio,dhw priority,boolean (>=0<=0), ,true,switch.boiler_dhw_dhw_priority,switch.boiler_dhw_dhwprio,6,9,1,66,1 "Cerapur Aero",boiler,167,dhw.starts,starts,uint24, ,false,sensor.boiler_dhw_starts,sensor.boiler_dhw_starts,6,9,1,67,2 "Cerapur Aero",boiler,167,dhw.workm,active time,time,minutes,false,sensor.boiler_dhw_active_time,sensor.boiler_dhw_workm,6,9,1,69,2 -"Cerapur Aero",boiler,167,nompower,nominal Power,uint8 (>=0<=0),kW,true,number.boiler_nominal_Power,number.boiler_nompower,6,0,1,279,1 -"Cerapur Aero",boiler,167,nrgtotal,total energy,uint24,kWh,false,sensor.boiler_total_energy,sensor.boiler_nrgtotal,6,0,1/100,88,2 -"Cerapur Aero",boiler,167,nrgheat,energy heating,uint24 (>=0<=10000000),kWh,true,number.boiler_energy_heating,number.boiler_nrgheat,6,0,1/100,90,2 +"Cerapur Aero",boiler,167,nompower,nominal Power,uint8 (>=0<=0),kW,true,number.boiler_nominal_Power,number.boiler_nompower,6,0,1,280,1 +"Cerapur Aero",boiler,167,nrgtotal,total energy,uint24,kWh,false,sensor.boiler_total_energy,sensor.boiler_nrgtotal,6,0,1/100,89,2 +"Cerapur Aero",boiler,167,nrgheat,energy heating,uint24 (>=0<=10000000),kWh,true,number.boiler_energy_heating,number.boiler_nrgheat,6,0,1/100,91,2 "Cerapur Aero",boiler,167,dhw.nrg,energy,uint24 (>=0<=10000000),kWh,true,number.boiler_dhw_energy,number.boiler_dhw_nrg,6,9,1/100,0,2 "Hybrid Heatpump",boiler,168,reset,reset,cmd [-\|maintenance\|error\|history\|message\|hp error\|burner starts\|factory] (>=0<=0), ,true,sensor.boiler_reset,sensor.boiler_reset,6,0,1,0,1 "Hybrid Heatpump",boiler,168,chimneysweeper,chimney sweeper,cmd [off\|on] (>=0<=0), ,true,sensor.boiler_chimney_sweeper,sensor.boiler_chimneysweeper,6,0,1,1,1 @@ -2391,28 +2410,28 @@ device name,device type,product id,shortname,fullname,type [options...] \| (min/ "Hybrid Heatpump",boiler,168,syspress,system pressure,uint8,bar,false,sensor.boiler_system_pressure,sensor.boiler_syspress,6,0,1/10,11,1 "Hybrid Heatpump",boiler,168,boiltemp,actual boiler temperature,uint16,C,false,sensor.boiler_actual_boiler_temperature,sensor.boiler_boiltemp,6,0,1/10,12,1 "Hybrid Heatpump",boiler,168,headertemp,low loss header,uint16,C,false,sensor.boiler_low_loss_header,sensor.boiler_headertemp,6,0,1/10,13,1 -"Hybrid Heatpump",boiler,168,exhausttemp,exhaust temperature,uint16,C,false,sensor.boiler_exhaust_temperature,sensor.boiler_exhausttemp,6,0,1/10,253,1 -"Hybrid Heatpump",boiler,168,burngas,gas,boolean, ,false,binary_sensor.boiler_gas,binary_sensor.boiler_burngas,6,0,1,254,1 -"Hybrid Heatpump",boiler,168,burngas2,gas stage 2,boolean, ,false,binary_sensor.boiler_gas_stage_2,binary_sensor.boiler_burngas2,6,0,1,255,1 -"Hybrid Heatpump",boiler,168,flamecurr,flame current,uint16,µA,false,sensor.boiler_flame_current,sensor.boiler_flamecurr,6,0,1/10,256,1 -"Hybrid Heatpump",boiler,168,fanwork,fan,boolean, ,false,binary_sensor.boiler_fan,binary_sensor.boiler_fanwork,6,0,1,257,1 -"Hybrid Heatpump",boiler,168,ignwork,ignition,boolean, ,false,binary_sensor.boiler_ignition,binary_sensor.boiler_ignwork,6,0,1,258,1 -"Hybrid Heatpump",boiler,168,oilpreheat,oil preheating,boolean, ,false,binary_sensor.boiler_oil_preheating,binary_sensor.boiler_oilpreheat,6,0,1,259,1 -"Hybrid Heatpump",boiler,168,burnminpower,burner min power,uint8 (>=0<=0),%,true,number.boiler_burner_min_power,number.boiler_burnminpower,6,0,1,260,1 -"Hybrid Heatpump",boiler,168,burnmaxpower,burner max power,uint8 (>=0<=254),%,true,number.boiler_burner_max_power,number.boiler_burnmaxpower,6,0,1,261,1 -"Hybrid Heatpump",boiler,168,burnminperiod,burner min period,uint8 (>=0<=120),minutes,true,number.boiler_burner_min_period,number.boiler_burnminperiod,6,0,1,262,1 -"Hybrid Heatpump",boiler,168,absburnpow,burner current power (absolute),uint8,%,false,sensor.boiler_burner_current_power_(absolute),sensor.boiler_absburnpow,6,0,1,263,1 -"Hybrid Heatpump",boiler,168,heatblock,Heatblock temperature,uint16,C,false,sensor.boiler_Heatblock_temperature,sensor.boiler_heatblock,6,0,1/10,264,1 -"Hybrid Heatpump",boiler,168,boilhyston,hysteresis on temperature,int8 (>=-20<=0),C,true,number.boiler_hysteresis_on_temperature,number.boiler_boilhyston,6,0,1,265,1 -"Hybrid Heatpump",boiler,168,boilhystoff,hysteresis off temperature,int8 (>=0<=20),C,true,number.boiler_hysteresis_off_temperature,number.boiler_boilhystoff,6,0,1,266,1 -"Hybrid Heatpump",boiler,168,boil2hyston,hysteresis stage 2 on temperature,int8 (>=-20<=0),C,true,number.boiler_hysteresis_stage_2_on_temperature,number.boiler_boil2hyston,6,0,1,267,1 -"Hybrid Heatpump",boiler,168,boil2hystoff,hysteresis stage 2 off temperature,int8 (>=0<=20),C,true,number.boiler_hysteresis_stage_2_off_temperature,number.boiler_boil2hystoff,6,0,1,268,1 -"Hybrid Heatpump",boiler,168,curveon,heatingcurve on,boolean (>=0<=0), ,true,switch.boiler_heatingcurve_on,switch.boiler_curveon,6,0,1,269,1 -"Hybrid Heatpump",boiler,168,curvebase,heatingcurve base,uint8 (>=20<=90),C,true,number.boiler_heatingcurve_base,number.boiler_curvebase,6,0,1,270,1 -"Hybrid Heatpump",boiler,168,curveend,heatingcurve end,uint8 (>=20<=90),C,true,number.boiler_heatingcurve_end,number.boiler_curveend,6,0,1,271,1 -"Hybrid Heatpump",boiler,168,summertemp,summer temperature,uint8 (>=0<=45),C,true,number.boiler_summer_temperature,number.boiler_summertemp,6,0,1,272,1 -"Hybrid Heatpump",boiler,168,nofrostmode,nofrost mode,boolean (>=0<=0), ,true,switch.boiler_nofrost_mode,switch.boiler_nofrostmode,6,0,1,273,1 -"Hybrid Heatpump",boiler,168,nofrosttemp,nofrost temperature,uint8 (>=0<=10),C,true,number.boiler_nofrost_temperature,number.boiler_nofrosttemp,6,0,1,274,1 +"Hybrid Heatpump",boiler,168,exhausttemp,exhaust temperature,uint16,C,false,sensor.boiler_exhaust_temperature,sensor.boiler_exhausttemp,6,0,1/10,254,1 +"Hybrid Heatpump",boiler,168,burngas,gas,boolean, ,false,binary_sensor.boiler_gas,binary_sensor.boiler_burngas,6,0,1,255,1 +"Hybrid Heatpump",boiler,168,burngas2,gas stage 2,boolean, ,false,binary_sensor.boiler_gas_stage_2,binary_sensor.boiler_burngas2,6,0,1,256,1 +"Hybrid Heatpump",boiler,168,flamecurr,flame current,uint16,µA,false,sensor.boiler_flame_current,sensor.boiler_flamecurr,6,0,1/10,257,1 +"Hybrid Heatpump",boiler,168,fanwork,fan,boolean, ,false,binary_sensor.boiler_fan,binary_sensor.boiler_fanwork,6,0,1,258,1 +"Hybrid Heatpump",boiler,168,ignwork,ignition,boolean, ,false,binary_sensor.boiler_ignition,binary_sensor.boiler_ignwork,6,0,1,259,1 +"Hybrid Heatpump",boiler,168,oilpreheat,oil preheating,boolean, ,false,binary_sensor.boiler_oil_preheating,binary_sensor.boiler_oilpreheat,6,0,1,260,1 +"Hybrid Heatpump",boiler,168,burnminpower,burner min power,uint8 (>=0<=0),%,true,number.boiler_burner_min_power,number.boiler_burnminpower,6,0,1,261,1 +"Hybrid Heatpump",boiler,168,burnmaxpower,burner max power,uint8 (>=0<=254),%,true,number.boiler_burner_max_power,number.boiler_burnmaxpower,6,0,1,262,1 +"Hybrid Heatpump",boiler,168,burnminperiod,burner min period,uint8 (>=0<=120),minutes,true,number.boiler_burner_min_period,number.boiler_burnminperiod,6,0,1,263,1 +"Hybrid Heatpump",boiler,168,absburnpow,burner current power (absolute),uint8,%,false,sensor.boiler_burner_current_power_(absolute),sensor.boiler_absburnpow,6,0,1,264,1 +"Hybrid Heatpump",boiler,168,heatblock,Heatblock temperature,uint16,C,false,sensor.boiler_Heatblock_temperature,sensor.boiler_heatblock,6,0,1/10,265,1 +"Hybrid Heatpump",boiler,168,boilhyston,hysteresis on temperature,int8 (>=-20<=0),C,true,number.boiler_hysteresis_on_temperature,number.boiler_boilhyston,6,0,1,266,1 +"Hybrid Heatpump",boiler,168,boilhystoff,hysteresis off temperature,int8 (>=0<=20),C,true,number.boiler_hysteresis_off_temperature,number.boiler_boilhystoff,6,0,1,267,1 +"Hybrid Heatpump",boiler,168,boil2hyston,hysteresis stage 2 on temperature,int8 (>=-20<=0),C,true,number.boiler_hysteresis_stage_2_on_temperature,number.boiler_boil2hyston,6,0,1,268,1 +"Hybrid Heatpump",boiler,168,boil2hystoff,hysteresis stage 2 off temperature,int8 (>=0<=20),C,true,number.boiler_hysteresis_stage_2_off_temperature,number.boiler_boil2hystoff,6,0,1,269,1 +"Hybrid Heatpump",boiler,168,curveon,heatingcurve on,boolean (>=0<=0), ,true,switch.boiler_heatingcurve_on,switch.boiler_curveon,6,0,1,270,1 +"Hybrid Heatpump",boiler,168,curvebase,heatingcurve base,uint8 (>=20<=90),C,true,number.boiler_heatingcurve_base,number.boiler_curvebase,6,0,1,271,1 +"Hybrid Heatpump",boiler,168,curveend,heatingcurve end,uint8 (>=20<=90),C,true,number.boiler_heatingcurve_end,number.boiler_curveend,6,0,1,272,1 +"Hybrid Heatpump",boiler,168,summertemp,summer temperature,uint8 (>=0<=45),C,true,number.boiler_summer_temperature,number.boiler_summertemp,6,0,1,273,1 +"Hybrid Heatpump",boiler,168,nofrostmode,nofrost mode,boolean (>=0<=0), ,true,switch.boiler_nofrost_mode,switch.boiler_nofrostmode,6,0,1,274,1 +"Hybrid Heatpump",boiler,168,nofrosttemp,nofrost temperature,uint8 (>=0<=10),C,true,number.boiler_nofrost_temperature,number.boiler_nofrosttemp,6,0,1,275,1 "Hybrid Heatpump",boiler,168,heatingactivated,heating activated,boolean (>=0<=0), ,true,switch.boiler_heating_activated,switch.boiler_heatingactivated,6,0,1,14,1 "Hybrid Heatpump",boiler,168,heatingtemp,heating temperature,uint8 (>=0<=90),C,true,number.boiler_heating_temperature,number.boiler_heatingtemp,6,0,1,15,1 "Hybrid Heatpump",boiler,168,heatingpump,heating pump,boolean, ,false,binary_sensor.boiler_heating_pump,binary_sensor.boiler_heatingpump,6,0,1,16,1 @@ -2439,18 +2458,19 @@ device name,device type,product id,shortname,fullname,type [options...] \| (min/ "Hybrid Heatpump",boiler,168,maintenancedate,next maintenance date,string (>=0<=0), ,true,sensor.boiler_next_maintenance_date,sensor.boiler_maintenancedate,6,0,1,72,6 "Hybrid Heatpump",boiler,168,emergencyops,emergency operation,boolean (>=0<=0), ,true,switch.boiler_emergency_operation,switch.boiler_emergencyops,6,0,1,78,1 "Hybrid Heatpump",boiler,168,emergencytemp,emergency temperature,uint8 (>=15<=70),C,true,number.boiler_emergency_temperature,number.boiler_emergencytemp,6,0,1,79,1 -"Hybrid Heatpump",boiler,168,pc0flow,Flow PC0,int16,l/h,false,sensor.boiler_Flow_PC0,sensor.boiler_pc0flow,6,0,1,80,1 -"Hybrid Heatpump",boiler,168,pc1flow,Flow PC1,int16,l/h,false,sensor.boiler_Flow_PC1,sensor.boiler_pc1flow,6,0,1,81,1 -"Hybrid Heatpump",boiler,168,pc1on,PC1,boolean, ,false,binary_sensor.boiler_PC1,binary_sensor.boiler_pc1on,6,0,1,82,1 -"Hybrid Heatpump",boiler,168,pc1rate,PC1 rate,uint8,%,false,sensor.boiler_PC1_rate,sensor.boiler_pc1rate,6,0,1,83,1 -"Hybrid Heatpump",boiler,168,pumpkickhour,pump kick hour,uint8 (>=0<=23),hours,true,number.boiler_pump_kick_hour,number.boiler_pumpkickhour,6,0,1,84,1 -"Hybrid Heatpump",boiler,168,pumpkickday,pump kick day,enum [mo\|tu\|we\|th\|fr\|sa\|su\|all] (>=0<=0), ,true,select.boiler_pump_kick_day,select.boiler_pumpkickday,6,0,1,85,1 -"Hybrid Heatpump",boiler,168,pumpkickdelay,pump kick delay,uint16 (>=0<=32767),minutes,true,number.boiler_pump_kick_delay,number.boiler_pumpkickdelay,6,0,1,86,1 -"Hybrid Heatpump",boiler,168,meterheat,meter heating,uint24,kWh,false,sensor.boiler_meter_heating,sensor.boiler_meterheat,6,0,1/10,100,2 +"Hybrid Heatpump",boiler,168,pc0lpm,Flow PC0,uint16,l/min,false,sensor.boiler_Flow_PC0,sensor.boiler_pc0lpm,6,0,1/10,80,1 +"Hybrid Heatpump",boiler,168,pc0flow,Flow PC0,uint16,l/h,false,sensor.boiler_Flow_PC0,sensor.boiler_pc0flow,6,0,1,81,1 +"Hybrid Heatpump",boiler,168,pc1flow,Flow PC1,uint16,l/h,false,sensor.boiler_Flow_PC1,sensor.boiler_pc1flow,6,0,1,82,1 +"Hybrid Heatpump",boiler,168,pc1on,PC1,boolean, ,false,binary_sensor.boiler_PC1,binary_sensor.boiler_pc1on,6,0,1,83,1 +"Hybrid Heatpump",boiler,168,pc1rate,PC1 rate,uint8,%,false,sensor.boiler_PC1_rate,sensor.boiler_pc1rate,6,0,1,84,1 +"Hybrid Heatpump",boiler,168,pumpkickhour,pump kick hour,uint8 (>=0<=23),hours,true,number.boiler_pump_kick_hour,number.boiler_pumpkickhour,6,0,1,85,1 +"Hybrid Heatpump",boiler,168,pumpkickday,pump kick day,enum [mo\|tu\|we\|th\|fr\|sa\|su\|all] (>=0<=0), ,true,select.boiler_pump_kick_day,select.boiler_pumpkickday,6,0,1,86,1 +"Hybrid Heatpump",boiler,168,pumpkickdelay,pump kick delay,uint16 (>=0<=32767),minutes,true,number.boiler_pump_kick_delay,number.boiler_pumpkickdelay,6,0,1,87,1 +"Hybrid Heatpump",boiler,168,meterheat,meter heating,uint24,kWh,false,sensor.boiler_meter_heating,sensor.boiler_meterheat,6,0,1/10,101,2 "Hybrid Heatpump",boiler,168,dhw.meter,meter,uint24,kWh,false,sensor.boiler_dhw_meter,sensor.boiler_dhw_meter,6,9,1/10,2,2 -"Hybrid Heatpump",boiler,168,gasmeterheat,gas meter heating,uint24,kWh,false,sensor.boiler_gas_meter_heating,sensor.boiler_gasmeterheat,6,0,1/10,275,2 +"Hybrid Heatpump",boiler,168,gasmeterheat,gas meter heating,uint24,kWh,false,sensor.boiler_gas_meter_heating,sensor.boiler_gasmeterheat,6,0,1/10,276,2 "Hybrid Heatpump",boiler,168,dhw.gasmeter,gas meter,uint24,kWh,false,sensor.boiler_dhw_gas_meter,sensor.boiler_dhw_gasmeter,6,9,1/10,71,2 -"Hybrid Heatpump",boiler,168,nrgheat2,energy heating 2,uint24,kWh,false,sensor.boiler_energy_heating_2,sensor.boiler_nrgheat2,6,0,1/10,277,2 +"Hybrid Heatpump",boiler,168,nrgheat2,energy heating 2,uint24,kWh,false,sensor.boiler_energy_heating_2,sensor.boiler_nrgheat2,6,0,1/10,278,2 "Hybrid Heatpump",boiler,168,dhw.nrg2,energy 2,uint24,kWh,false,sensor.boiler_dhw_energy_2,sensor.boiler_dhw_nrg2,6,9,1/10,73,2 "Hybrid Heatpump",boiler,168,dhw.tapactivated,turn on/off,boolean (>=0<=0), ,true,switch.boiler_dhw_turn_on/off,switch.boiler_dhw_tapactivated,6,9,1,28,1 "Hybrid Heatpump",boiler,168,dhw.settemp,set temperature,uint8,C,false,sensor.boiler_dhw_set_temperature,sensor.boiler_dhw_settemp,6,9,1,29,1 @@ -2493,9 +2513,9 @@ device name,device type,product id,shortname,fullname,type [options...] \| (min/ "Hybrid Heatpump",boiler,168,dhw.dhwprio,dhw priority,boolean (>=0<=0), ,true,switch.boiler_dhw_dhw_priority,switch.boiler_dhw_dhwprio,6,9,1,66,1 "Hybrid Heatpump",boiler,168,dhw.starts,starts,uint24, ,false,sensor.boiler_dhw_starts,sensor.boiler_dhw_starts,6,9,1,67,2 "Hybrid Heatpump",boiler,168,dhw.workm,active time,time,minutes,false,sensor.boiler_dhw_active_time,sensor.boiler_dhw_workm,6,9,1,69,2 -"Hybrid Heatpump",boiler,168,nompower,nominal Power,uint8 (>=0<=0),kW,true,number.boiler_nominal_Power,number.boiler_nompower,6,0,1,279,1 -"Hybrid Heatpump",boiler,168,nrgtotal,total energy,uint24,kWh,false,sensor.boiler_total_energy,sensor.boiler_nrgtotal,6,0,1/100,88,2 -"Hybrid Heatpump",boiler,168,nrgheat,energy heating,uint24 (>=0<=10000000),kWh,true,number.boiler_energy_heating,number.boiler_nrgheat,6,0,1/100,90,2 +"Hybrid Heatpump",boiler,168,nompower,nominal Power,uint8 (>=0<=0),kW,true,number.boiler_nominal_Power,number.boiler_nompower,6,0,1,280,1 +"Hybrid Heatpump",boiler,168,nrgtotal,total energy,uint24,kWh,false,sensor.boiler_total_energy,sensor.boiler_nrgtotal,6,0,1/100,89,2 +"Hybrid Heatpump",boiler,168,nrgheat,energy heating,uint24 (>=0<=10000000),kWh,true,number.boiler_energy_heating,number.boiler_nrgheat,6,0,1/100,91,2 "Hybrid Heatpump",boiler,168,dhw.nrg,energy,uint24 (>=0<=10000000),kWh,true,number.boiler_dhw_energy,number.boiler_dhw_nrg,6,9,1/100,0,2 "Logano GB212",boiler,170,reset,reset,cmd [-\|maintenance\|error\|history\|message\|hp error\|burner starts\|factory] (>=0<=0), ,true,sensor.boiler_reset,sensor.boiler_reset,6,0,1,0,1 "Logano GB212",boiler,170,chimneysweeper,chimney sweeper,cmd [off\|on] (>=0<=0), ,true,sensor.boiler_chimney_sweeper,sensor.boiler_chimneysweeper,6,0,1,1,1 @@ -2511,28 +2531,28 @@ device name,device type,product id,shortname,fullname,type [options...] \| (min/ "Logano GB212",boiler,170,syspress,system pressure,uint8,bar,false,sensor.boiler_system_pressure,sensor.boiler_syspress,6,0,1/10,11,1 "Logano GB212",boiler,170,boiltemp,actual boiler temperature,uint16,C,false,sensor.boiler_actual_boiler_temperature,sensor.boiler_boiltemp,6,0,1/10,12,1 "Logano GB212",boiler,170,headertemp,low loss header,uint16,C,false,sensor.boiler_low_loss_header,sensor.boiler_headertemp,6,0,1/10,13,1 -"Logano GB212",boiler,170,exhausttemp,exhaust temperature,uint16,C,false,sensor.boiler_exhaust_temperature,sensor.boiler_exhausttemp,6,0,1/10,253,1 -"Logano GB212",boiler,170,burngas,gas,boolean, ,false,binary_sensor.boiler_gas,binary_sensor.boiler_burngas,6,0,1,254,1 -"Logano GB212",boiler,170,burngas2,gas stage 2,boolean, ,false,binary_sensor.boiler_gas_stage_2,binary_sensor.boiler_burngas2,6,0,1,255,1 -"Logano GB212",boiler,170,flamecurr,flame current,uint16,µA,false,sensor.boiler_flame_current,sensor.boiler_flamecurr,6,0,1/10,256,1 -"Logano GB212",boiler,170,fanwork,fan,boolean, ,false,binary_sensor.boiler_fan,binary_sensor.boiler_fanwork,6,0,1,257,1 -"Logano GB212",boiler,170,ignwork,ignition,boolean, ,false,binary_sensor.boiler_ignition,binary_sensor.boiler_ignwork,6,0,1,258,1 -"Logano GB212",boiler,170,oilpreheat,oil preheating,boolean, ,false,binary_sensor.boiler_oil_preheating,binary_sensor.boiler_oilpreheat,6,0,1,259,1 -"Logano GB212",boiler,170,burnminpower,burner min power,uint8 (>=0<=0),%,true,number.boiler_burner_min_power,number.boiler_burnminpower,6,0,1,260,1 -"Logano GB212",boiler,170,burnmaxpower,burner max power,uint8 (>=0<=254),%,true,number.boiler_burner_max_power,number.boiler_burnmaxpower,6,0,1,261,1 -"Logano GB212",boiler,170,burnminperiod,burner min period,uint8 (>=0<=120),minutes,true,number.boiler_burner_min_period,number.boiler_burnminperiod,6,0,1,262,1 -"Logano GB212",boiler,170,absburnpow,burner current power (absolute),uint8,%,false,sensor.boiler_burner_current_power_(absolute),sensor.boiler_absburnpow,6,0,1,263,1 -"Logano GB212",boiler,170,heatblock,Heatblock temperature,uint16,C,false,sensor.boiler_Heatblock_temperature,sensor.boiler_heatblock,6,0,1/10,264,1 -"Logano GB212",boiler,170,boilhyston,hysteresis on temperature,int8 (>=-20<=0),C,true,number.boiler_hysteresis_on_temperature,number.boiler_boilhyston,6,0,1,265,1 -"Logano GB212",boiler,170,boilhystoff,hysteresis off temperature,int8 (>=0<=20),C,true,number.boiler_hysteresis_off_temperature,number.boiler_boilhystoff,6,0,1,266,1 -"Logano GB212",boiler,170,boil2hyston,hysteresis stage 2 on temperature,int8 (>=-20<=0),C,true,number.boiler_hysteresis_stage_2_on_temperature,number.boiler_boil2hyston,6,0,1,267,1 -"Logano GB212",boiler,170,boil2hystoff,hysteresis stage 2 off temperature,int8 (>=0<=20),C,true,number.boiler_hysteresis_stage_2_off_temperature,number.boiler_boil2hystoff,6,0,1,268,1 -"Logano GB212",boiler,170,curveon,heatingcurve on,boolean (>=0<=0), ,true,switch.boiler_heatingcurve_on,switch.boiler_curveon,6,0,1,269,1 -"Logano GB212",boiler,170,curvebase,heatingcurve base,uint8 (>=20<=90),C,true,number.boiler_heatingcurve_base,number.boiler_curvebase,6,0,1,270,1 -"Logano GB212",boiler,170,curveend,heatingcurve end,uint8 (>=20<=90),C,true,number.boiler_heatingcurve_end,number.boiler_curveend,6,0,1,271,1 -"Logano GB212",boiler,170,summertemp,summer temperature,uint8 (>=0<=45),C,true,number.boiler_summer_temperature,number.boiler_summertemp,6,0,1,272,1 -"Logano GB212",boiler,170,nofrostmode,nofrost mode,boolean (>=0<=0), ,true,switch.boiler_nofrost_mode,switch.boiler_nofrostmode,6,0,1,273,1 -"Logano GB212",boiler,170,nofrosttemp,nofrost temperature,uint8 (>=0<=10),C,true,number.boiler_nofrost_temperature,number.boiler_nofrosttemp,6,0,1,274,1 +"Logano GB212",boiler,170,exhausttemp,exhaust temperature,uint16,C,false,sensor.boiler_exhaust_temperature,sensor.boiler_exhausttemp,6,0,1/10,254,1 +"Logano GB212",boiler,170,burngas,gas,boolean, ,false,binary_sensor.boiler_gas,binary_sensor.boiler_burngas,6,0,1,255,1 +"Logano GB212",boiler,170,burngas2,gas stage 2,boolean, ,false,binary_sensor.boiler_gas_stage_2,binary_sensor.boiler_burngas2,6,0,1,256,1 +"Logano GB212",boiler,170,flamecurr,flame current,uint16,µA,false,sensor.boiler_flame_current,sensor.boiler_flamecurr,6,0,1/10,257,1 +"Logano GB212",boiler,170,fanwork,fan,boolean, ,false,binary_sensor.boiler_fan,binary_sensor.boiler_fanwork,6,0,1,258,1 +"Logano GB212",boiler,170,ignwork,ignition,boolean, ,false,binary_sensor.boiler_ignition,binary_sensor.boiler_ignwork,6,0,1,259,1 +"Logano GB212",boiler,170,oilpreheat,oil preheating,boolean, ,false,binary_sensor.boiler_oil_preheating,binary_sensor.boiler_oilpreheat,6,0,1,260,1 +"Logano GB212",boiler,170,burnminpower,burner min power,uint8 (>=0<=0),%,true,number.boiler_burner_min_power,number.boiler_burnminpower,6,0,1,261,1 +"Logano GB212",boiler,170,burnmaxpower,burner max power,uint8 (>=0<=254),%,true,number.boiler_burner_max_power,number.boiler_burnmaxpower,6,0,1,262,1 +"Logano GB212",boiler,170,burnminperiod,burner min period,uint8 (>=0<=120),minutes,true,number.boiler_burner_min_period,number.boiler_burnminperiod,6,0,1,263,1 +"Logano GB212",boiler,170,absburnpow,burner current power (absolute),uint8,%,false,sensor.boiler_burner_current_power_(absolute),sensor.boiler_absburnpow,6,0,1,264,1 +"Logano GB212",boiler,170,heatblock,Heatblock temperature,uint16,C,false,sensor.boiler_Heatblock_temperature,sensor.boiler_heatblock,6,0,1/10,265,1 +"Logano GB212",boiler,170,boilhyston,hysteresis on temperature,int8 (>=-20<=0),C,true,number.boiler_hysteresis_on_temperature,number.boiler_boilhyston,6,0,1,266,1 +"Logano GB212",boiler,170,boilhystoff,hysteresis off temperature,int8 (>=0<=20),C,true,number.boiler_hysteresis_off_temperature,number.boiler_boilhystoff,6,0,1,267,1 +"Logano GB212",boiler,170,boil2hyston,hysteresis stage 2 on temperature,int8 (>=-20<=0),C,true,number.boiler_hysteresis_stage_2_on_temperature,number.boiler_boil2hyston,6,0,1,268,1 +"Logano GB212",boiler,170,boil2hystoff,hysteresis stage 2 off temperature,int8 (>=0<=20),C,true,number.boiler_hysteresis_stage_2_off_temperature,number.boiler_boil2hystoff,6,0,1,269,1 +"Logano GB212",boiler,170,curveon,heatingcurve on,boolean (>=0<=0), ,true,switch.boiler_heatingcurve_on,switch.boiler_curveon,6,0,1,270,1 +"Logano GB212",boiler,170,curvebase,heatingcurve base,uint8 (>=20<=90),C,true,number.boiler_heatingcurve_base,number.boiler_curvebase,6,0,1,271,1 +"Logano GB212",boiler,170,curveend,heatingcurve end,uint8 (>=20<=90),C,true,number.boiler_heatingcurve_end,number.boiler_curveend,6,0,1,272,1 +"Logano GB212",boiler,170,summertemp,summer temperature,uint8 (>=0<=45),C,true,number.boiler_summer_temperature,number.boiler_summertemp,6,0,1,273,1 +"Logano GB212",boiler,170,nofrostmode,nofrost mode,boolean (>=0<=0), ,true,switch.boiler_nofrost_mode,switch.boiler_nofrostmode,6,0,1,274,1 +"Logano GB212",boiler,170,nofrosttemp,nofrost temperature,uint8 (>=0<=10),C,true,number.boiler_nofrost_temperature,number.boiler_nofrosttemp,6,0,1,275,1 "Logano GB212",boiler,170,heatingactivated,heating activated,boolean (>=0<=0), ,true,switch.boiler_heating_activated,switch.boiler_heatingactivated,6,0,1,14,1 "Logano GB212",boiler,170,heatingtemp,heating temperature,uint8 (>=0<=90),C,true,number.boiler_heating_temperature,number.boiler_heatingtemp,6,0,1,15,1 "Logano GB212",boiler,170,heatingpump,heating pump,boolean, ,false,binary_sensor.boiler_heating_pump,binary_sensor.boiler_heatingpump,6,0,1,16,1 @@ -2559,18 +2579,19 @@ device name,device type,product id,shortname,fullname,type [options...] \| (min/ "Logano GB212",boiler,170,maintenancedate,next maintenance date,string (>=0<=0), ,true,sensor.boiler_next_maintenance_date,sensor.boiler_maintenancedate,6,0,1,72,6 "Logano GB212",boiler,170,emergencyops,emergency operation,boolean (>=0<=0), ,true,switch.boiler_emergency_operation,switch.boiler_emergencyops,6,0,1,78,1 "Logano GB212",boiler,170,emergencytemp,emergency temperature,uint8 (>=15<=70),C,true,number.boiler_emergency_temperature,number.boiler_emergencytemp,6,0,1,79,1 -"Logano GB212",boiler,170,pc0flow,Flow PC0,int16,l/h,false,sensor.boiler_Flow_PC0,sensor.boiler_pc0flow,6,0,1,80,1 -"Logano GB212",boiler,170,pc1flow,Flow PC1,int16,l/h,false,sensor.boiler_Flow_PC1,sensor.boiler_pc1flow,6,0,1,81,1 -"Logano GB212",boiler,170,pc1on,PC1,boolean, ,false,binary_sensor.boiler_PC1,binary_sensor.boiler_pc1on,6,0,1,82,1 -"Logano GB212",boiler,170,pc1rate,PC1 rate,uint8,%,false,sensor.boiler_PC1_rate,sensor.boiler_pc1rate,6,0,1,83,1 -"Logano GB212",boiler,170,pumpkickhour,pump kick hour,uint8 (>=0<=23),hours,true,number.boiler_pump_kick_hour,number.boiler_pumpkickhour,6,0,1,84,1 -"Logano GB212",boiler,170,pumpkickday,pump kick day,enum [mo\|tu\|we\|th\|fr\|sa\|su\|all] (>=0<=0), ,true,select.boiler_pump_kick_day,select.boiler_pumpkickday,6,0,1,85,1 -"Logano GB212",boiler,170,pumpkickdelay,pump kick delay,uint16 (>=0<=32767),minutes,true,number.boiler_pump_kick_delay,number.boiler_pumpkickdelay,6,0,1,86,1 -"Logano GB212",boiler,170,meterheat,meter heating,uint24,kWh,false,sensor.boiler_meter_heating,sensor.boiler_meterheat,6,0,1/10,100,2 +"Logano GB212",boiler,170,pc0lpm,Flow PC0,uint16,l/min,false,sensor.boiler_Flow_PC0,sensor.boiler_pc0lpm,6,0,1/10,80,1 +"Logano GB212",boiler,170,pc0flow,Flow PC0,uint16,l/h,false,sensor.boiler_Flow_PC0,sensor.boiler_pc0flow,6,0,1,81,1 +"Logano GB212",boiler,170,pc1flow,Flow PC1,uint16,l/h,false,sensor.boiler_Flow_PC1,sensor.boiler_pc1flow,6,0,1,82,1 +"Logano GB212",boiler,170,pc1on,PC1,boolean, ,false,binary_sensor.boiler_PC1,binary_sensor.boiler_pc1on,6,0,1,83,1 +"Logano GB212",boiler,170,pc1rate,PC1 rate,uint8,%,false,sensor.boiler_PC1_rate,sensor.boiler_pc1rate,6,0,1,84,1 +"Logano GB212",boiler,170,pumpkickhour,pump kick hour,uint8 (>=0<=23),hours,true,number.boiler_pump_kick_hour,number.boiler_pumpkickhour,6,0,1,85,1 +"Logano GB212",boiler,170,pumpkickday,pump kick day,enum [mo\|tu\|we\|th\|fr\|sa\|su\|all] (>=0<=0), ,true,select.boiler_pump_kick_day,select.boiler_pumpkickday,6,0,1,86,1 +"Logano GB212",boiler,170,pumpkickdelay,pump kick delay,uint16 (>=0<=32767),minutes,true,number.boiler_pump_kick_delay,number.boiler_pumpkickdelay,6,0,1,87,1 +"Logano GB212",boiler,170,meterheat,meter heating,uint24,kWh,false,sensor.boiler_meter_heating,sensor.boiler_meterheat,6,0,1/10,101,2 "Logano GB212",boiler,170,dhw.meter,meter,uint24,kWh,false,sensor.boiler_dhw_meter,sensor.boiler_dhw_meter,6,9,1/10,2,2 -"Logano GB212",boiler,170,gasmeterheat,gas meter heating,uint24,kWh,false,sensor.boiler_gas_meter_heating,sensor.boiler_gasmeterheat,6,0,1/10,275,2 +"Logano GB212",boiler,170,gasmeterheat,gas meter heating,uint24,kWh,false,sensor.boiler_gas_meter_heating,sensor.boiler_gasmeterheat,6,0,1/10,276,2 "Logano GB212",boiler,170,dhw.gasmeter,gas meter,uint24,kWh,false,sensor.boiler_dhw_gas_meter,sensor.boiler_dhw_gasmeter,6,9,1/10,71,2 -"Logano GB212",boiler,170,nrgheat2,energy heating 2,uint24,kWh,false,sensor.boiler_energy_heating_2,sensor.boiler_nrgheat2,6,0,1/10,277,2 +"Logano GB212",boiler,170,nrgheat2,energy heating 2,uint24,kWh,false,sensor.boiler_energy_heating_2,sensor.boiler_nrgheat2,6,0,1/10,278,2 "Logano GB212",boiler,170,dhw.nrg2,energy 2,uint24,kWh,false,sensor.boiler_dhw_energy_2,sensor.boiler_dhw_nrg2,6,9,1/10,73,2 "Logano GB212",boiler,170,dhw.tapactivated,turn on/off,boolean (>=0<=0), ,true,switch.boiler_dhw_turn_on/off,switch.boiler_dhw_tapactivated,6,9,1,28,1 "Logano GB212",boiler,170,dhw.settemp,set temperature,uint8,C,false,sensor.boiler_dhw_set_temperature,sensor.boiler_dhw_settemp,6,9,1,29,1 @@ -2613,9 +2634,9 @@ device name,device type,product id,shortname,fullname,type [options...] \| (min/ "Logano GB212",boiler,170,dhw.dhwprio,dhw priority,boolean (>=0<=0), ,true,switch.boiler_dhw_dhw_priority,switch.boiler_dhw_dhwprio,6,9,1,66,1 "Logano GB212",boiler,170,dhw.starts,starts,uint24, ,false,sensor.boiler_dhw_starts,sensor.boiler_dhw_starts,6,9,1,67,2 "Logano GB212",boiler,170,dhw.workm,active time,time,minutes,false,sensor.boiler_dhw_active_time,sensor.boiler_dhw_workm,6,9,1,69,2 -"Logano GB212",boiler,170,nompower,nominal Power,uint8 (>=0<=0),kW,true,number.boiler_nominal_Power,number.boiler_nompower,6,0,1,279,1 -"Logano GB212",boiler,170,nrgtotal,total energy,uint24,kWh,false,sensor.boiler_total_energy,sensor.boiler_nrgtotal,6,0,1/100,88,2 -"Logano GB212",boiler,170,nrgheat,energy heating,uint24 (>=0<=10000000),kWh,true,number.boiler_energy_heating,number.boiler_nrgheat,6,0,1/100,90,2 +"Logano GB212",boiler,170,nompower,nominal Power,uint8 (>=0<=0),kW,true,number.boiler_nominal_Power,number.boiler_nompower,6,0,1,280,1 +"Logano GB212",boiler,170,nrgtotal,total energy,uint24,kWh,false,sensor.boiler_total_energy,sensor.boiler_nrgtotal,6,0,1/100,89,2 +"Logano GB212",boiler,170,nrgheat,energy heating,uint24 (>=0<=10000000),kWh,true,number.boiler_energy_heating,number.boiler_nrgheat,6,0,1/100,91,2 "Logano GB212",boiler,170,dhw.nrg,energy,uint24 (>=0<=10000000),kWh,true,number.boiler_dhw_energy,number.boiler_dhw_nrg,6,9,1/100,0,2 "Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i",boiler,172,reset,reset,cmd [-\|maintenance\|error\|history\|message\|hp error\|burner starts\|factory] (>=0<=0), ,true,sensor.boiler_reset,sensor.boiler_reset,6,0,1,0,1 "Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i",boiler,172,chimneysweeper,chimney sweeper,cmd [off\|on] (>=0<=0), ,true,sensor.boiler_chimney_sweeper,sensor.boiler_chimneysweeper,6,0,1,1,1 @@ -2657,130 +2678,131 @@ device name,device type,product id,shortname,fullname,type [options...] \| (min/ "Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i",boiler,172,maintenancedate,next maintenance date,string (>=0<=0), ,true,sensor.boiler_next_maintenance_date,sensor.boiler_maintenancedate,6,0,1,72,6 "Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i",boiler,172,emergencyops,emergency operation,boolean (>=0<=0), ,true,switch.boiler_emergency_operation,switch.boiler_emergencyops,6,0,1,78,1 "Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i",boiler,172,emergencytemp,emergency temperature,uint8 (>=15<=70),C,true,number.boiler_emergency_temperature,number.boiler_emergencytemp,6,0,1,79,1 -"Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i",boiler,172,pc0flow,Flow PC0,int16,l/h,false,sensor.boiler_Flow_PC0,sensor.boiler_pc0flow,6,0,1,80,1 -"Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i",boiler,172,pc1flow,Flow PC1,int16,l/h,false,sensor.boiler_Flow_PC1,sensor.boiler_pc1flow,6,0,1,81,1 -"Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i",boiler,172,pc1on,PC1,boolean, ,false,binary_sensor.boiler_PC1,binary_sensor.boiler_pc1on,6,0,1,82,1 -"Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i",boiler,172,pc1rate,PC1 rate,uint8,%,false,sensor.boiler_PC1_rate,sensor.boiler_pc1rate,6,0,1,83,1 -"Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i",boiler,172,pumpkickhour,pump kick hour,uint8 (>=0<=23),hours,true,number.boiler_pump_kick_hour,number.boiler_pumpkickhour,6,0,1,84,1 -"Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i",boiler,172,pumpkickday,pump kick day,enum [mo\|tu\|we\|th\|fr\|sa\|su\|all] (>=0<=0), ,true,select.boiler_pump_kick_day,select.boiler_pumpkickday,6,0,1,85,1 -"Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i",boiler,172,pumpkickdelay,pump kick delay,uint16 (>=0<=32767),minutes,true,number.boiler_pump_kick_delay,number.boiler_pumpkickdelay,6,0,1,86,1 -"Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i",boiler,172,mandefrost,manual defrost,cmd [off\|on] (>=0<=0), ,true,sensor.boiler_manual_defrost,sensor.boiler_mandefrost,6,0,1,87,1 -"Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i",boiler,172,nrgtotal,total energy,uint24,kWh,false,sensor.boiler_total_energy,sensor.boiler_nrgtotal,6,0,1/100,88,2 +"Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i",boiler,172,pc0lpm,Flow PC0,uint16,l/min,false,sensor.boiler_Flow_PC0,sensor.boiler_pc0lpm,6,0,1/10,80,1 +"Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i",boiler,172,pc0flow,Flow PC0,uint16,l/h,false,sensor.boiler_Flow_PC0,sensor.boiler_pc0flow,6,0,1,81,1 +"Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i",boiler,172,pc1flow,Flow PC1,uint16,l/h,false,sensor.boiler_Flow_PC1,sensor.boiler_pc1flow,6,0,1,82,1 +"Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i",boiler,172,pc1on,PC1,boolean, ,false,binary_sensor.boiler_PC1,binary_sensor.boiler_pc1on,6,0,1,83,1 +"Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i",boiler,172,pc1rate,PC1 rate,uint8,%,false,sensor.boiler_PC1_rate,sensor.boiler_pc1rate,6,0,1,84,1 +"Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i",boiler,172,pumpkickhour,pump kick hour,uint8 (>=0<=23),hours,true,number.boiler_pump_kick_hour,number.boiler_pumpkickhour,6,0,1,85,1 +"Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i",boiler,172,pumpkickday,pump kick day,enum [mo\|tu\|we\|th\|fr\|sa\|su\|all] (>=0<=0), ,true,select.boiler_pump_kick_day,select.boiler_pumpkickday,6,0,1,86,1 +"Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i",boiler,172,pumpkickdelay,pump kick delay,uint16 (>=0<=32767),minutes,true,number.boiler_pump_kick_delay,number.boiler_pumpkickdelay,6,0,1,87,1 +"Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i",boiler,172,mandefrost,manual defrost,cmd [off\|on] (>=0<=0), ,true,sensor.boiler_manual_defrost,sensor.boiler_mandefrost,6,0,1,88,1 +"Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i",boiler,172,nrgtotal,total energy,uint24,kWh,false,sensor.boiler_total_energy,sensor.boiler_nrgtotal,6,0,1/100,89,2 "Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i",boiler,172,dhw.nrg,energy,uint24,kWh,false,sensor.boiler_dhw_energy,sensor.boiler_dhw_nrg,6,9,1/100,0,2 -"Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i",boiler,172,nrgheat,energy heating,uint24,kWh,false,sensor.boiler_energy_heating,sensor.boiler_nrgheat,6,0,1/100,90,2 -"Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i",boiler,172,nrgcool,energy cooling,uint24,kWh,false,sensor.boiler_energy_cooling,sensor.boiler_nrgcool,6,0,1/100,92,2 -"Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i",boiler,172,metertotal,meter total,uint24,kWh,false,sensor.boiler_meter_total,sensor.boiler_metertotal,6,0,1/100,94,2 -"Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i",boiler,172,metercomp,meter compressor,uint24,kWh,false,sensor.boiler_meter_compressor,sensor.boiler_metercomp,6,0,1/100,96,2 -"Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i",boiler,172,metereheat,meter e-heater,uint24,kWh,false,sensor.boiler_meter_e-heater,sensor.boiler_metereheat,6,0,1/100,98,2 -"Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i",boiler,172,meterheat,meter heating,uint24,kWh,false,sensor.boiler_meter_heating,sensor.boiler_meterheat,6,0,1/100,100,2 -"Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i",boiler,172,metercool,meter cooling,uint24,kWh,false,sensor.boiler_meter_cooling,sensor.boiler_metercool,6,0,1/100,102,2 +"Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i",boiler,172,nrgheat,energy heating,uint24,kWh,false,sensor.boiler_energy_heating,sensor.boiler_nrgheat,6,0,1/100,91,2 +"Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i",boiler,172,nrgcool,energy cooling,uint24,kWh,false,sensor.boiler_energy_cooling,sensor.boiler_nrgcool,6,0,1/100,93,2 +"Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i",boiler,172,metertotal,meter total,uint24,kWh,false,sensor.boiler_meter_total,sensor.boiler_metertotal,6,0,1/100,95,2 +"Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i",boiler,172,metercomp,meter compressor,uint24,kWh,false,sensor.boiler_meter_compressor,sensor.boiler_metercomp,6,0,1/100,97,2 +"Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i",boiler,172,metereheat,meter e-heater,uint24,kWh,false,sensor.boiler_meter_e-heater,sensor.boiler_metereheat,6,0,1/100,99,2 +"Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i",boiler,172,meterheat,meter heating,uint24,kWh,false,sensor.boiler_meter_heating,sensor.boiler_meterheat,6,0,1/100,101,2 +"Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i",boiler,172,metercool,meter cooling,uint24,kWh,false,sensor.boiler_meter_cooling,sensor.boiler_metercool,6,0,1/100,103,2 "Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i",boiler,172,dhw.meter,meter,uint24,kWh,false,sensor.boiler_dhw_meter,sensor.boiler_dhw_meter,6,9,1/100,2,2 -"Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i",boiler,172,uptimetotal,heatpump total uptime,time,minutes,false,sensor.boiler_heatpump_total_uptime,sensor.boiler_uptimetotal,6,0,1/60,104,2 -"Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i",boiler,172,uptimecontrol,total operating time heat,time,minutes,false,sensor.boiler_total_operating_time_heat,sensor.boiler_uptimecontrol,6,0,1/60,106,2 -"Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i",boiler,172,uptimecompheating,operating time compressor heating,time,minutes,false,sensor.boiler_operating_time_compressor_heating,sensor.boiler_uptimecompheating,6,0,1/60,108,2 -"Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i",boiler,172,uptimecompcooling,operating time compressor cooling,time,minutes,false,sensor.boiler_operating_time_compressor_cooling,sensor.boiler_uptimecompcooling,6,0,1/60,110,2 +"Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i",boiler,172,uptimetotal,heatpump total uptime,time,minutes,false,sensor.boiler_heatpump_total_uptime,sensor.boiler_uptimetotal,6,0,1/60,105,2 +"Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i",boiler,172,uptimecontrol,total operating time heat,time,minutes,false,sensor.boiler_total_operating_time_heat,sensor.boiler_uptimecontrol,6,0,1/60,107,2 +"Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i",boiler,172,uptimecompheating,operating time compressor heating,time,minutes,false,sensor.boiler_operating_time_compressor_heating,sensor.boiler_uptimecompheating,6,0,1/60,109,2 +"Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i",boiler,172,uptimecompcooling,operating time compressor cooling,time,minutes,false,sensor.boiler_operating_time_compressor_cooling,sensor.boiler_uptimecompcooling,6,0,1/60,111,2 "Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i",boiler,172,dhw.uptimecomp,operating time compressor,time,minutes,false,sensor.boiler_dhw_operating_time_compressor,sensor.boiler_dhw_uptimecomp,6,9,1/60,4,2 -"Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i",boiler,172,uptimecomppool,operating time compressor pool,time,minutes,false,sensor.boiler_operating_time_compressor_pool,sensor.boiler_uptimecomppool,6,0,1/60,112,2 -"Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i",boiler,172,totalcompstarts,total compressor control starts,uint24, ,false,sensor.boiler_total_compressor_control_starts,sensor.boiler_totalcompstarts,6,0,1,114,2 -"Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i",boiler,172,heatingstarts,heating control starts,uint24, ,false,sensor.boiler_heating_control_starts,sensor.boiler_heatingstarts,6,0,1,116,2 -"Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i",boiler,172,coolingstarts,cooling control starts,uint24, ,false,sensor.boiler_cooling_control_starts,sensor.boiler_coolingstarts,6,0,1,118,2 +"Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i",boiler,172,uptimecomppool,operating time compressor pool,time,minutes,false,sensor.boiler_operating_time_compressor_pool,sensor.boiler_uptimecomppool,6,0,1/60,113,2 +"Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i",boiler,172,totalcompstarts,total compressor control starts,uint24, ,false,sensor.boiler_total_compressor_control_starts,sensor.boiler_totalcompstarts,6,0,1,115,2 +"Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i",boiler,172,heatingstarts,heating control starts,uint24, ,false,sensor.boiler_heating_control_starts,sensor.boiler_heatingstarts,6,0,1,117,2 +"Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i",boiler,172,coolingstarts,cooling control starts,uint24, ,false,sensor.boiler_cooling_control_starts,sensor.boiler_coolingstarts,6,0,1,119,2 "Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i",boiler,172,dhw.startshp,starts hp,uint24, ,false,sensor.boiler_dhw_starts_hp,sensor.boiler_dhw_startshp,6,9,1,6,2 -"Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i",boiler,172,poolstarts,pool control starts,uint24, ,false,sensor.boiler_pool_control_starts,sensor.boiler_poolstarts,6,0,1,120,2 -"Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i",boiler,172,nrgconstotal,total energy consumption,uint24,kWh,false,sensor.boiler_total_energy_consumption,sensor.boiler_nrgconstotal,6,0,1,122,2 -"Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i",boiler,172,nrgconscomptotal,total energy consumption compressor,uint24,kWh,false,sensor.boiler_total_energy_consumption_compressor,sensor.boiler_nrgconscomptotal,6,0,1,124,2 -"Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i",boiler,172,nrgconscompheating,energy consumption compressor heating,uint24,kWh,false,sensor.boiler_energy_consumption_compressor_heating,sensor.boiler_nrgconscompheating,6,0,1,126,2 +"Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i",boiler,172,poolstarts,pool control starts,uint24, ,false,sensor.boiler_pool_control_starts,sensor.boiler_poolstarts,6,0,1,121,2 +"Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i",boiler,172,nrgconstotal,total energy consumption,uint24,kWh,false,sensor.boiler_total_energy_consumption,sensor.boiler_nrgconstotal,6,0,1,123,2 +"Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i",boiler,172,nrgconscomptotal,total energy consumption compressor,uint24,kWh,false,sensor.boiler_total_energy_consumption_compressor,sensor.boiler_nrgconscomptotal,6,0,1,125,2 +"Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i",boiler,172,nrgconscompheating,energy consumption compressor heating,uint24,kWh,false,sensor.boiler_energy_consumption_compressor_heating,sensor.boiler_nrgconscompheating,6,0,1,127,2 "Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i",boiler,172,dhw.nrgconscomp,energy consumption compressor,uint24,kWh,false,sensor.boiler_dhw_energy_consumption_compressor,sensor.boiler_dhw_nrgconscomp,6,9,1,8,2 -"Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i",boiler,172,nrgconscompcooling,energy consumption compressor cooling,uint24,kWh,false,sensor.boiler_energy_consumption_compressor_cooling,sensor.boiler_nrgconscompcooling,6,0,1,128,2 -"Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i",boiler,172,nrgconscomppool,energy consumption compressor pool,uint24,kWh,false,sensor.boiler_energy_consumption_compressor_pool,sensor.boiler_nrgconscomppool,6,0,1,130,2 -"Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i",boiler,172,auxelecheatnrgconstotal,total aux elec. heater energy consumption,uint24,kWh,false,sensor.boiler_total_aux_elec._heater_energy_consumption,sensor.boiler_auxelecheatnrgconstotal,6,0,1,132,2 -"Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i",boiler,172,auxelecheatnrgconsheating,aux elec. heater energy consumption heating,uint24,kWh,false,sensor.boiler_aux_elec._heater_energy_consumption_heating,sensor.boiler_auxelecheatnrgconsheating,6,0,1,134,2 +"Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i",boiler,172,nrgconscompcooling,energy consumption compressor cooling,uint24,kWh,false,sensor.boiler_energy_consumption_compressor_cooling,sensor.boiler_nrgconscompcooling,6,0,1,129,2 +"Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i",boiler,172,nrgconscomppool,energy consumption compressor pool,uint24,kWh,false,sensor.boiler_energy_consumption_compressor_pool,sensor.boiler_nrgconscomppool,6,0,1,131,2 +"Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i",boiler,172,auxelecheatnrgconstotal,total aux elec. heater energy consumption,uint24,kWh,false,sensor.boiler_total_aux_elec._heater_energy_consumption,sensor.boiler_auxelecheatnrgconstotal,6,0,1,133,2 +"Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i",boiler,172,auxelecheatnrgconsheating,aux elec. heater energy consumption heating,uint24,kWh,false,sensor.boiler_aux_elec._heater_energy_consumption_heating,sensor.boiler_auxelecheatnrgconsheating,6,0,1,135,2 "Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i",boiler,172,dhw.auxelecheatnrgcons,aux elec. heater energy consumption,uint24,kWh,false,sensor.boiler_dhw_aux_elec._heater_energy_consumption,sensor.boiler_dhw_auxelecheatnrgcons,6,9,1,10,2 -"Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i",boiler,172,auxelecheatnrgconspool,aux elec. heater energy consumption pool,uint24,kWh,false,sensor.boiler_aux_elec._heater_energy_consumption_pool,sensor.boiler_auxelecheatnrgconspool,6,0,1,136,2 -"Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i",boiler,172,nrgsupptotal,total energy supplied,uint24,kWh,false,sensor.boiler_total_energy_supplied,sensor.boiler_nrgsupptotal,6,0,1,138,2 -"Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i",boiler,172,nrgsuppheating,total energy supplied heating,uint24,kWh,false,sensor.boiler_total_energy_supplied_heating,sensor.boiler_nrgsuppheating,6,0,1,140,2 +"Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i",boiler,172,auxelecheatnrgconspool,aux elec. heater energy consumption pool,uint24,kWh,false,sensor.boiler_aux_elec._heater_energy_consumption_pool,sensor.boiler_auxelecheatnrgconspool,6,0,1,137,2 +"Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i",boiler,172,nrgsupptotal,total energy supplied,uint24,kWh,false,sensor.boiler_total_energy_supplied,sensor.boiler_nrgsupptotal,6,0,1,139,2 +"Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i",boiler,172,nrgsuppheating,total energy supplied heating,uint24,kWh,false,sensor.boiler_total_energy_supplied_heating,sensor.boiler_nrgsuppheating,6,0,1,141,2 "Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i",boiler,172,dhw.nrgsupp,total energy warm supplied,uint24,kWh,false,sensor.boiler_dhw_total_energy_warm_supplied,sensor.boiler_dhw_nrgsupp,6,9,1,12,2 -"Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i",boiler,172,nrgsuppcooling,total energy supplied cooling,uint24,kWh,false,sensor.boiler_total_energy_supplied_cooling,sensor.boiler_nrgsuppcooling,6,0,1,142,2 -"Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i",boiler,172,nrgsupppool,total energy supplied pool,uint24,kWh,false,sensor.boiler_total_energy_supplied_pool,sensor.boiler_nrgsupppool,6,0,1,144,2 -"Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i",boiler,172,hppower,compressor power output,uint16,kW,false,sensor.boiler_compressor_power_output,sensor.boiler_hppower,6,0,1/10,146,1 -"Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i",boiler,172,hpmaxpower,compressor max power,uint8 (>=0<=0),%,true,number.boiler_compressor_max_power,number.boiler_hpmaxpower,6,0,1,147,1 -"Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i",boiler,172,pvmaxcomp,pv compressor max power,uint8 (>=0<=0),kW,true,number.boiler_pv_compressor_max_power,number.boiler_pvmaxcomp,6,0,1/10,148,1 -"Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i",boiler,172,powerreduction,power reduction,uint8 (>=30<=60),%,true,number.boiler_power_reduction,number.boiler_powerreduction,6,0,10,149,1 -"Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i",boiler,172,hpsetdiffpress,set differential pressure,uint8 (>=150<=750),mbar,true,number.boiler_set_differential_pressure,number.boiler_hpsetdiffpress,6,0,50,150,1 -"Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i",boiler,172,hpcompon,hp compressor,boolean, ,false,binary_sensor.boiler_hp_compressor,binary_sensor.boiler_hpcompon,6,0,1,151,1 -"Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i",boiler,172,hpactivity,compressor activity,enum [off\|heating\|cooling\|hot water\|pool\|pool heating\|defrost\|compressor alarm], ,false,sensor.boiler_compressor_activity,sensor.boiler_hpactivity,6,0,1,152,1 -"Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i",boiler,172,hpbrinepumpspd,brine pump speed,uint8,%,false,sensor.boiler_brine_pump_speed,sensor.boiler_hpbrinepumpspd,6,0,1,153,1 -"Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i",boiler,172,hpswitchvalve,switch valve,boolean, ,false,binary_sensor.boiler_switch_valve,binary_sensor.boiler_hpswitchvalve,6,0,1,154,1 -"Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i",boiler,172,hpcompspd,compressor speed,uint8,%,false,sensor.boiler_compressor_speed,sensor.boiler_hpcompspd,6,0,1,155,1 -"Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i",boiler,172,hptargetspd,compressor target speed,uint8,%,false,sensor.boiler_compressor_target_speed,sensor.boiler_hptargetspd,6,0,1,156,1 -"Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i",boiler,172,hpcircspd,circulation pump speed,uint8,%,false,sensor.boiler_circulation_pump_speed,sensor.boiler_hpcircspd,6,0,1,157,1 -"Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i",boiler,172,recvalve,receiver valve VR0,uint8,%,false,sensor.boiler_receiver_valve_VR0,sensor.boiler_recvalve,6,0,1,158,1 -"Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i",boiler,172,expvalve,expansion valve VR1,uint8,%,false,sensor.boiler_expansion_valve_VR1,sensor.boiler_expvalve,6,0,1,159,1 -"Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i",boiler,172,hpbrinein,brine in/evaporator,int16,C,false,sensor.boiler_brine_in/evaporator,sensor.boiler_hpbrinein,6,0,1/10,160,1 -"Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i",boiler,172,hpbrineout,brine out/condenser,int16,C,false,sensor.boiler_brine_out/condenser,sensor.boiler_hpbrineout,6,0,1/10,161,1 -"Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i",boiler,172,hptc0,heat carrier return (TC0),int16,C,false,sensor.boiler_heat_carrier_return_(TC0),sensor.boiler_hptc0,6,0,1/10,162,1 -"Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i",boiler,172,hptc1,heat carrier forward (TC1),int16,C,false,sensor.boiler_heat_carrier_forward_(TC1),sensor.boiler_hptc1,6,0,1/10,163,1 -"Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i",boiler,172,hptc3,condenser temperature (TC3),int16,C,false,sensor.boiler_condenser_temperature_(TC3),sensor.boiler_hptc3,6,0,1/10,164,1 -"Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i",boiler,172,hptr1,compressor temperature (TR1),int16,C,false,sensor.boiler_compressor_temperature_(TR1),sensor.boiler_hptr1,6,0,1/10,165,1 -"Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i",boiler,172,hptr3,refrigerant temperature liquid side (condenser output) (TR3),int16,C,false,sensor.boiler_refrigerant_temperature_liquid_side_(condenser_output)_(TR3),sensor.boiler_hptr3,6,0,1/10,166,1 -"Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i",boiler,172,hptr4,evaporator inlet temperature (TR4),int16,C,false,sensor.boiler_evaporator_inlet_temperature_(TR4),sensor.boiler_hptr4,6,0,1/10,167,1 -"Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i",boiler,172,hptr5,compressor inlet temperature (TR5),int16,C,false,sensor.boiler_compressor_inlet_temperature_(TR5),sensor.boiler_hptr5,6,0,1/10,168,1 -"Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i",boiler,172,hptr6,compressor outlet temperature (TR6),int16,C,false,sensor.boiler_compressor_outlet_temperature_(TR6),sensor.boiler_hptr6,6,0,1/10,169,1 -"Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i",boiler,172,hptr7,refrigerant temperature gas side (condenser input) (TR7),int16,C,false,sensor.boiler_refrigerant_temperature_gas_side_(condenser_input)_(TR7),sensor.boiler_hptr7,6,0,1/10,170,1 -"Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i",boiler,172,hptl2,air inlet temperature (TL2),int16,C,false,sensor.boiler_air_inlet_temperature_(TL2),sensor.boiler_hptl2,6,0,1/10,171,1 -"Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i",boiler,172,hppl1,low pressure side temperature (PL1),int16,C,false,sensor.boiler_low_pressure_side_temperature_(PL1),sensor.boiler_hppl1,6,0,1/10,172,1 -"Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i",boiler,172,hpph1,high pressure side temperature (PH1),int16,C,false,sensor.boiler_high_pressure_side_temperature_(PH1),sensor.boiler_hpph1,6,0,1/10,173,1 -"Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i",boiler,172,hpta4,drain pan temp (TA4),int16,C,false,sensor.boiler_drain_pan_temp_(TA4),sensor.boiler_hpta4,6,0,1/10,174,1 -"Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i",boiler,172,hptw1,reservoir temp (TW1),int16,C,false,sensor.boiler_reservoir_temp_(TW1),sensor.boiler_hptw1,6,0,1/10,175,1 -"Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i",boiler,172,poolsettemp,pool set temperature,uint8 (>=0<=0),C,true,number.boiler_pool_set_temperature,number.boiler_poolsettemp,6,0,1/2,176,1 -"Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i",boiler,172,hp4way,4-way valve (VR4),boolean, ,false,binary_sensor.boiler_4-way_valve_(VR4),binary_sensor.boiler_hp4way,6,0,1,177,1 -"Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i",boiler,172,hpin1,input 1 state,boolean, ,false,binary_sensor.boiler_input_1_state,binary_sensor.boiler_hpin1,6,0,1,178,1 -"Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i",boiler,172,hpin1opt,input 1 options,string (>=0<=0), ,true,sensor.boiler_input_1_options,sensor.boiler_hpin1opt,6,0,1,179,8 -"Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i",boiler,172,hpin2,input 2 state,boolean, ,false,binary_sensor.boiler_input_2_state,binary_sensor.boiler_hpin2,6,0,1,187,1 -"Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i",boiler,172,hpin2opt,input 2 options,string (>=0<=0), ,true,sensor.boiler_input_2_options,sensor.boiler_hpin2opt,6,0,1,188,8 -"Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i",boiler,172,hpin3,input 3 state,boolean, ,false,binary_sensor.boiler_input_3_state,binary_sensor.boiler_hpin3,6,0,1,196,1 -"Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i",boiler,172,hpin3opt,input 3 options,string (>=0<=0), ,true,sensor.boiler_input_3_options,sensor.boiler_hpin3opt,6,0,1,197,8 -"Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i",boiler,172,hpin4,input 4 state,boolean, ,false,binary_sensor.boiler_input_4_state,binary_sensor.boiler_hpin4,6,0,1,205,1 -"Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i",boiler,172,hpin4opt,input 4 options,string (>=0<=0), ,true,sensor.boiler_input_4_options,sensor.boiler_hpin4opt,6,0,1,206,8 -"Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i",boiler,172,maxheatcomp,heat limit compressor,enum [0 kW\|2 kW\|3 kW\|4 kW\|6 kW\|9 kW] (>=0<=0), ,true,select.boiler_heat_limit_compressor,select.boiler_maxheatcomp,6,0,1,214,1 -"Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i",boiler,172,maxheatheat,heat limit heating,enum [0 kW\|2 kW\|3 kW\|4 kW\|6 kW\|9 kW] (>=0<=0), ,true,select.boiler_heat_limit_heating,select.boiler_maxheatheat,6,0,1,215,1 +"Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i",boiler,172,nrgsuppcooling,total energy supplied cooling,uint24,kWh,false,sensor.boiler_total_energy_supplied_cooling,sensor.boiler_nrgsuppcooling,6,0,1,143,2 +"Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i",boiler,172,nrgsupppool,total energy supplied pool,uint24,kWh,false,sensor.boiler_total_energy_supplied_pool,sensor.boiler_nrgsupppool,6,0,1,145,2 +"Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i",boiler,172,hppower,compressor power output,uint16,kW,false,sensor.boiler_compressor_power_output,sensor.boiler_hppower,6,0,1/10,147,1 +"Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i",boiler,172,hpmaxpower,compressor max power,uint8 (>=0<=0),%,true,number.boiler_compressor_max_power,number.boiler_hpmaxpower,6,0,1,148,1 +"Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i",boiler,172,pvmaxcomp,pv compressor max power,uint8 (>=0<=0),kW,true,number.boiler_pv_compressor_max_power,number.boiler_pvmaxcomp,6,0,1/10,149,1 +"Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i",boiler,172,powerreduction,power reduction,uint8 (>=30<=60),%,true,number.boiler_power_reduction,number.boiler_powerreduction,6,0,10,150,1 +"Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i",boiler,172,hpsetdiffpress,set differential pressure,uint8 (>=150<=750),mbar,true,number.boiler_set_differential_pressure,number.boiler_hpsetdiffpress,6,0,50,151,1 +"Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i",boiler,172,hpcompon,hp compressor,boolean, ,false,binary_sensor.boiler_hp_compressor,binary_sensor.boiler_hpcompon,6,0,1,152,1 +"Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i",boiler,172,hpactivity,compressor activity,enum [off\|heating\|cooling\|hot water\|pool\|pool heating\|defrost\|compressor alarm], ,false,sensor.boiler_compressor_activity,sensor.boiler_hpactivity,6,0,1,153,1 +"Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i",boiler,172,hpbrinepumpspd,brine pump speed,uint8,%,false,sensor.boiler_brine_pump_speed,sensor.boiler_hpbrinepumpspd,6,0,1,154,1 +"Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i",boiler,172,hpswitchvalve,switch valve,boolean, ,false,binary_sensor.boiler_switch_valve,binary_sensor.boiler_hpswitchvalve,6,0,1,155,1 +"Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i",boiler,172,hpcompspd,compressor speed,uint8,%,false,sensor.boiler_compressor_speed,sensor.boiler_hpcompspd,6,0,1,156,1 +"Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i",boiler,172,hptargetspd,compressor target speed,uint8,%,false,sensor.boiler_compressor_target_speed,sensor.boiler_hptargetspd,6,0,1,157,1 +"Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i",boiler,172,hpcircspd,circulation pump speed,uint8,%,false,sensor.boiler_circulation_pump_speed,sensor.boiler_hpcircspd,6,0,1,158,1 +"Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i",boiler,172,recvalve,receiver valve VR0,uint8,%,false,sensor.boiler_receiver_valve_VR0,sensor.boiler_recvalve,6,0,1,159,1 +"Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i",boiler,172,expvalve,expansion valve VR1,uint8,%,false,sensor.boiler_expansion_valve_VR1,sensor.boiler_expvalve,6,0,1,160,1 +"Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i",boiler,172,hpbrinein,brine in/evaporator,int16,C,false,sensor.boiler_brine_in/evaporator,sensor.boiler_hpbrinein,6,0,1/10,161,1 +"Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i",boiler,172,hpbrineout,brine out/condenser,int16,C,false,sensor.boiler_brine_out/condenser,sensor.boiler_hpbrineout,6,0,1/10,162,1 +"Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i",boiler,172,hptc0,heat carrier return (TC0),int16,C,false,sensor.boiler_heat_carrier_return_(TC0),sensor.boiler_hptc0,6,0,1/10,163,1 +"Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i",boiler,172,hptc1,heat carrier forward (TC1),int16,C,false,sensor.boiler_heat_carrier_forward_(TC1),sensor.boiler_hptc1,6,0,1/10,164,1 +"Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i",boiler,172,hptc3,condenser temperature (TC3),int16,C,false,sensor.boiler_condenser_temperature_(TC3),sensor.boiler_hptc3,6,0,1/10,165,1 +"Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i",boiler,172,hptr1,compressor temperature (TR1),int16,C,false,sensor.boiler_compressor_temperature_(TR1),sensor.boiler_hptr1,6,0,1/10,166,1 +"Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i",boiler,172,hptr3,refrigerant temperature liquid side (condenser output) (TR3),int16,C,false,sensor.boiler_refrigerant_temperature_liquid_side_(condenser_output)_(TR3),sensor.boiler_hptr3,6,0,1/10,167,1 +"Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i",boiler,172,hptr4,evaporator inlet temperature (TR4),int16,C,false,sensor.boiler_evaporator_inlet_temperature_(TR4),sensor.boiler_hptr4,6,0,1/10,168,1 +"Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i",boiler,172,hptr5,compressor inlet temperature (TR5),int16,C,false,sensor.boiler_compressor_inlet_temperature_(TR5),sensor.boiler_hptr5,6,0,1/10,169,1 +"Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i",boiler,172,hptr6,compressor outlet temperature (TR6),int16,C,false,sensor.boiler_compressor_outlet_temperature_(TR6),sensor.boiler_hptr6,6,0,1/10,170,1 +"Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i",boiler,172,hptr7,refrigerant temperature gas side (condenser input) (TR7),int16,C,false,sensor.boiler_refrigerant_temperature_gas_side_(condenser_input)_(TR7),sensor.boiler_hptr7,6,0,1/10,171,1 +"Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i",boiler,172,hptl2,air inlet temperature (TL2),int16,C,false,sensor.boiler_air_inlet_temperature_(TL2),sensor.boiler_hptl2,6,0,1/10,172,1 +"Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i",boiler,172,hppl1,low pressure side temperature (PL1),int16,C,false,sensor.boiler_low_pressure_side_temperature_(PL1),sensor.boiler_hppl1,6,0,1/10,173,1 +"Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i",boiler,172,hpph1,high pressure side temperature (PH1),int16,C,false,sensor.boiler_high_pressure_side_temperature_(PH1),sensor.boiler_hpph1,6,0,1/10,174,1 +"Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i",boiler,172,hpta4,drain pan temp (TA4),int16,C,false,sensor.boiler_drain_pan_temp_(TA4),sensor.boiler_hpta4,6,0,1/10,175,1 +"Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i",boiler,172,hptw1,reservoir temp (TW1),int16,C,false,sensor.boiler_reservoir_temp_(TW1),sensor.boiler_hptw1,6,0,1/10,176,1 +"Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i",boiler,172,poolsettemp,pool set temperature,uint8 (>=0<=0),C,true,number.boiler_pool_set_temperature,number.boiler_poolsettemp,6,0,1/2,177,1 +"Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i",boiler,172,hp4way,4-way valve (VR4),boolean, ,false,binary_sensor.boiler_4-way_valve_(VR4),binary_sensor.boiler_hp4way,6,0,1,178,1 +"Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i",boiler,172,hpin1,input 1 state,boolean, ,false,binary_sensor.boiler_input_1_state,binary_sensor.boiler_hpin1,6,0,1,179,1 +"Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i",boiler,172,hpin1opt,input 1 options,string (>=0<=0), ,true,sensor.boiler_input_1_options,sensor.boiler_hpin1opt,6,0,1,180,8 +"Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i",boiler,172,hpin2,input 2 state,boolean, ,false,binary_sensor.boiler_input_2_state,binary_sensor.boiler_hpin2,6,0,1,188,1 +"Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i",boiler,172,hpin2opt,input 2 options,string (>=0<=0), ,true,sensor.boiler_input_2_options,sensor.boiler_hpin2opt,6,0,1,189,8 +"Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i",boiler,172,hpin3,input 3 state,boolean, ,false,binary_sensor.boiler_input_3_state,binary_sensor.boiler_hpin3,6,0,1,197,1 +"Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i",boiler,172,hpin3opt,input 3 options,string (>=0<=0), ,true,sensor.boiler_input_3_options,sensor.boiler_hpin3opt,6,0,1,198,8 +"Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i",boiler,172,hpin4,input 4 state,boolean, ,false,binary_sensor.boiler_input_4_state,binary_sensor.boiler_hpin4,6,0,1,206,1 +"Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i",boiler,172,hpin4opt,input 4 options,string (>=0<=0), ,true,sensor.boiler_input_4_options,sensor.boiler_hpin4opt,6,0,1,207,8 +"Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i",boiler,172,maxheatcomp,heat limit compressor,enum [0 kW\|2 kW\|3 kW\|4 kW\|6 kW\|9 kW] (>=0<=0), ,true,select.boiler_heat_limit_compressor,select.boiler_maxheatcomp,6,0,1,215,1 +"Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i",boiler,172,maxheatheat,heat limit heating,enum [0 kW\|2 kW\|3 kW\|4 kW\|6 kW\|9 kW] (>=0<=0), ,true,select.boiler_heat_limit_heating,select.boiler_maxheatheat,6,0,1,216,1 "Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i",boiler,172,dhw.maxheat,heat limit,enum [0 kW\|2 kW\|3 kW\|4 kW\|6 kW\|9 kW] (>=0<=0), ,true,select.boiler_dhw_heat_limit,select.boiler_dhw_maxheat,6,9,1,14,1 -"Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i",boiler,172,auxheatersource,aux heater source,enum [not installed\|electric heater\|exclusive\|parallel\|hybrid] (>=0<=0), ,true,select.boiler_aux_heater_source,select.boiler_auxheatersource,6,0,1,216,1 -"Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i",boiler,172,pvcooling,cooling only with PV,boolean (>=0<=0), ,true,switch.boiler_cooling_only_with_PV,switch.boiler_pvcooling,6,0,1,217,1 -"Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i",boiler,172,auxheateronly,aux heater only,boolean (>=0<=0), ,true,switch.boiler_aux_heater_only,switch.boiler_auxheateronly,6,0,1,218,1 -"Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i",boiler,172,auxheateroff,disable aux heater,boolean (>=0<=0), ,true,switch.boiler_disable_aux_heater,switch.boiler_auxheateroff,6,0,1,219,1 -"Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i",boiler,172,auxheaterstatus,aux heater status,enum [off\|heating\|cooling\|hot water\|pool\|pool heating\|defrost\|compressor alarm], ,false,sensor.boiler_aux_heater_status,sensor.boiler_auxheaterstatus,6,0,1,220,1 -"Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i",boiler,172,auxheaterlevel,aux heater level,uint8,%,false,sensor.boiler_aux_heater_level,sensor.boiler_auxheaterlevel,6,0,1,221,1 -"Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i",boiler,172,auxheaterdelay,aux heater on delay,uint16 (>=10<=1000),K*min,true,number.boiler_aux_heater_on_delay,number.boiler_auxheaterdelay,6,0,10,222,1 -"Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i",boiler,172,auxmaxlimit,aux heater max limit,uint8 (>=0<=10),K,true,number.boiler_aux_heater_max_limit,number.boiler_auxmaxlimit,6,0,1/10,223,1 -"Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i",boiler,172,auxlimitstart,aux heater limit start,uint8 (>=0<=10),K,true,number.boiler_aux_heater_limit_start,number.boiler_auxlimitstart,6,0,1/10,224,1 -"Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i",boiler,172,auxheatrmode,aux heater mode,enum [eco\|comfort] (>=0<=0), ,true,select.boiler_aux_heater_mode,select.boiler_auxheatrmode,6,0,1,225,1 -"Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i",boiler,172,hphystheat,on/off hyst heat,uint16 (>=50<=1500),K*min,true,number.boiler_on/off_hyst_heat,number.boiler_hphystheat,6,0,5,226,1 -"Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i",boiler,172,hphystcool,on/off hyst cool,uint16 (>=50<=1500),K*min,true,number.boiler_on/off_hyst_cool,number.boiler_hphystcool,6,0,5,227,1 -"Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i",boiler,172,hphystpool,on/off hyst pool,uint16 (>=50<=1500),K*min,true,number.boiler_on/off_hyst_pool,number.boiler_hphystpool,6,0,5,228,1 -"Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i",boiler,172,silentmode,silent mode,enum [off\|auto\|on] (>=0<=0), ,true,select.boiler_silent_mode,select.boiler_silentmode,6,0,1,229,1 -"Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i",boiler,172,silentfrom,silent mode from,uint8 (>=0<=0),minutes,true,number.boiler_silent_mode_from,number.boiler_silentfrom,6,0,15,230,1 -"Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i",boiler,172,silentto,silent mode to,uint8 (>=0<=0),minutes,true,number.boiler_silent_mode_to,number.boiler_silentto,6,0,15,231,1 -"Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i",boiler,172,mintempsilent,min outside temp for silent mode,int8 (>=0<=0),C,true,number.boiler_min_outside_temp_for_silent_mode,number.boiler_mintempsilent,6,0,1,232,1 -"Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i",boiler,172,tempparmode,outside temp parallel mode,int8 (>=0<=0),C,true,number.boiler_outside_temp_parallel_mode,number.boiler_tempparmode,6,0,1,233,1 -"Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i",boiler,172,auxheatmix,aux heater mixing valve,int8,%,false,sensor.boiler_aux_heater_mixing_valve,sensor.boiler_auxheatmix,6,0,1,234,1 -"Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i",boiler,172,tempdiffheat,temp diff TC3/TC0 heat,uint8 (>=2<=10),K,true,number.boiler_temp_diff_TC3/TC0_heat,number.boiler_tempdiffheat,6,0,1/10,235,1 -"Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i",boiler,172,tempdiffcool,temp diff TC3/TC0 cool,uint8 (>=2<=10),K,true,number.boiler_temp_diff_TC3/TC0_cool,number.boiler_tempdiffcool,6,0,1/10,236,1 -"Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i",boiler,172,vpcooling,valve/pump cooling,boolean (>=0<=0), ,true,switch.boiler_valve/pump_cooling,switch.boiler_vpcooling,6,0,1,237,1 -"Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i",boiler,172,heatcable,heating cable,boolean (>=0<=0), ,true,switch.boiler_heating_cable,switch.boiler_heatcable,6,0,1,238,1 -"Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i",boiler,172,vc0valve,VC0 valve,boolean (>=0<=0), ,true,switch.boiler_VC0_valve,switch.boiler_vc0valve,6,0,1,239,1 -"Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i",boiler,172,primepump,primary heatpump,boolean (>=0<=0), ,true,switch.boiler_primary_heatpump,switch.boiler_primepump,6,0,1,240,1 -"Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i",boiler,172,primepumpmod,primary heatpump modulation,uint8 (>=0<=0),%,true,number.boiler_primary_heatpump_modulation,number.boiler_primepumpmod,6,0,1,241,1 -"Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i",boiler,172,hp3way,3-way valve,boolean (>=0<=0), ,true,switch.boiler_3-way_valve,switch.boiler_hp3way,6,0,1,242,1 -"Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i",boiler,172,elheatstep1,el. heater step 1,boolean (>=0<=0), ,true,switch.boiler_el._heater_step_1,switch.boiler_elheatstep1,6,0,1,243,1 -"Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i",boiler,172,elheatstep2,el. heater step 2,boolean (>=0<=0), ,true,switch.boiler_el._heater_step_2,switch.boiler_elheatstep2,6,0,1,244,1 -"Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i",boiler,172,elheatstep3,el. heater step 3,boolean (>=0<=0), ,true,switch.boiler_el._heater_step_3,switch.boiler_elheatstep3,6,0,1,245,1 -"Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i",boiler,172,hpea0,condensate reservoir heating (EA0),boolean, ,false,binary_sensor.boiler_condensate_reservoir_heating_(EA0),binary_sensor.boiler_hpea0,6,0,1,246,1 -"Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i",boiler,172,hppumpmode,primary heatpump mode,enum [auto\|continuous] (>=0<=0), ,true,select.boiler_primary_heatpump_mode,select.boiler_hppumpmode,6,0,1,247,1 -"Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i",boiler,172,fan,fan,uint8 (>=20<=100),%,true,number.boiler_fan,number.boiler_fan,6,0,1,248,1 -"Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i",boiler,172,fanspd,fan speed,uint8,%,false,sensor.boiler_fan_speed,sensor.boiler_fanspd,6,0,1,249,1 -"Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i",boiler,172,shutdown,shutdown,cmd [off\|on] (>=0<=0), ,true,sensor.boiler_shutdown,sensor.boiler_shutdown,6,0,1,250,1 -"Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i",boiler,172,hpcurrpower,compressor current power,uint16,W,false,sensor.boiler_compressor_current_power,sensor.boiler_hpcurrpower,6,0,1,251,1 -"Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i",boiler,172,hppowerlimit,power limit,uint16 (>=0<=0),W,true,number.boiler_power_limit,number.boiler_hppowerlimit,6,0,1,252,1 +"Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i",boiler,172,auxheatersource,aux heater source,enum [not installed\|electric heater\|exclusive\|parallel\|hybrid] (>=0<=0), ,true,select.boiler_aux_heater_source,select.boiler_auxheatersource,6,0,1,217,1 +"Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i",boiler,172,pvcooling,cooling only with PV,boolean (>=0<=0), ,true,switch.boiler_cooling_only_with_PV,switch.boiler_pvcooling,6,0,1,218,1 +"Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i",boiler,172,auxheateronly,aux heater only,boolean (>=0<=0), ,true,switch.boiler_aux_heater_only,switch.boiler_auxheateronly,6,0,1,219,1 +"Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i",boiler,172,auxheateroff,disable aux heater,boolean (>=0<=0), ,true,switch.boiler_disable_aux_heater,switch.boiler_auxheateroff,6,0,1,220,1 +"Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i",boiler,172,auxheaterstatus,aux heater status,enum [off\|heating\|cooling\|hot water\|pool\|pool heating\|defrost\|compressor alarm], ,false,sensor.boiler_aux_heater_status,sensor.boiler_auxheaterstatus,6,0,1,221,1 +"Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i",boiler,172,auxheaterlevel,aux heater level,uint8,%,false,sensor.boiler_aux_heater_level,sensor.boiler_auxheaterlevel,6,0,1,222,1 +"Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i",boiler,172,auxheaterdelay,aux heater on delay,uint16 (>=10<=1000),K*min,true,number.boiler_aux_heater_on_delay,number.boiler_auxheaterdelay,6,0,10,223,1 +"Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i",boiler,172,auxmaxlimit,aux heater max limit,uint8 (>=0<=10),K,true,number.boiler_aux_heater_max_limit,number.boiler_auxmaxlimit,6,0,1/10,224,1 +"Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i",boiler,172,auxlimitstart,aux heater limit start,uint8 (>=0<=10),K,true,number.boiler_aux_heater_limit_start,number.boiler_auxlimitstart,6,0,1/10,225,1 +"Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i",boiler,172,auxheatrmode,aux heater mode,enum [eco\|comfort] (>=0<=0), ,true,select.boiler_aux_heater_mode,select.boiler_auxheatrmode,6,0,1,226,1 +"Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i",boiler,172,hphystheat,on/off hyst heat,uint16 (>=50<=1500),K*min,true,number.boiler_on/off_hyst_heat,number.boiler_hphystheat,6,0,5,227,1 +"Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i",boiler,172,hphystcool,on/off hyst cool,uint16 (>=50<=1500),K*min,true,number.boiler_on/off_hyst_cool,number.boiler_hphystcool,6,0,5,228,1 +"Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i",boiler,172,hphystpool,on/off hyst pool,uint16 (>=50<=1500),K*min,true,number.boiler_on/off_hyst_pool,number.boiler_hphystpool,6,0,5,229,1 +"Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i",boiler,172,silentmode,silent mode,enum [off\|auto\|on] (>=0<=0), ,true,select.boiler_silent_mode,select.boiler_silentmode,6,0,1,230,1 +"Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i",boiler,172,silentfrom,silent mode from,uint8 (>=0<=0),minutes,true,number.boiler_silent_mode_from,number.boiler_silentfrom,6,0,15,231,1 +"Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i",boiler,172,silentto,silent mode to,uint8 (>=0<=0),minutes,true,number.boiler_silent_mode_to,number.boiler_silentto,6,0,15,232,1 +"Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i",boiler,172,mintempsilent,min outside temp for silent mode,int8 (>=0<=0),C,true,number.boiler_min_outside_temp_for_silent_mode,number.boiler_mintempsilent,6,0,1,233,1 +"Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i",boiler,172,tempparmode,outside temp parallel mode,int8 (>=0<=0),C,true,number.boiler_outside_temp_parallel_mode,number.boiler_tempparmode,6,0,1,234,1 +"Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i",boiler,172,auxheatmix,aux heater mixing valve,int8,%,false,sensor.boiler_aux_heater_mixing_valve,sensor.boiler_auxheatmix,6,0,1,235,1 +"Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i",boiler,172,tempdiffheat,temp diff TC3/TC0 heat,uint8 (>=2<=10),K,true,number.boiler_temp_diff_TC3/TC0_heat,number.boiler_tempdiffheat,6,0,1/10,236,1 +"Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i",boiler,172,tempdiffcool,temp diff TC3/TC0 cool,uint8 (>=2<=10),K,true,number.boiler_temp_diff_TC3/TC0_cool,number.boiler_tempdiffcool,6,0,1/10,237,1 +"Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i",boiler,172,vpcooling,valve/pump cooling,boolean (>=0<=0), ,true,switch.boiler_valve/pump_cooling,switch.boiler_vpcooling,6,0,1,238,1 +"Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i",boiler,172,heatcable,heating cable,boolean (>=0<=0), ,true,switch.boiler_heating_cable,switch.boiler_heatcable,6,0,1,239,1 +"Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i",boiler,172,vc0valve,VC0 valve,boolean (>=0<=0), ,true,switch.boiler_VC0_valve,switch.boiler_vc0valve,6,0,1,240,1 +"Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i",boiler,172,primepump,primary heatpump,boolean (>=0<=0), ,true,switch.boiler_primary_heatpump,switch.boiler_primepump,6,0,1,241,1 +"Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i",boiler,172,primepumpmod,primary heatpump modulation,uint8 (>=0<=0),%,true,number.boiler_primary_heatpump_modulation,number.boiler_primepumpmod,6,0,1,242,1 +"Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i",boiler,172,hp3way,3-way valve,boolean (>=0<=0), ,true,switch.boiler_3-way_valve,switch.boiler_hp3way,6,0,1,243,1 +"Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i",boiler,172,elheatstep1,el. heater step 1,boolean (>=0<=0), ,true,switch.boiler_el._heater_step_1,switch.boiler_elheatstep1,6,0,1,244,1 +"Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i",boiler,172,elheatstep2,el. heater step 2,boolean (>=0<=0), ,true,switch.boiler_el._heater_step_2,switch.boiler_elheatstep2,6,0,1,245,1 +"Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i",boiler,172,elheatstep3,el. heater step 3,boolean (>=0<=0), ,true,switch.boiler_el._heater_step_3,switch.boiler_elheatstep3,6,0,1,246,1 +"Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i",boiler,172,hpea0,condensate reservoir heating (EA0),boolean, ,false,binary_sensor.boiler_condensate_reservoir_heating_(EA0),binary_sensor.boiler_hpea0,6,0,1,247,1 +"Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i",boiler,172,hppumpmode,primary heatpump mode,enum [auto\|continuous] (>=0<=0), ,true,select.boiler_primary_heatpump_mode,select.boiler_hppumpmode,6,0,1,248,1 +"Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i",boiler,172,fan,fan,uint8 (>=20<=100),%,true,number.boiler_fan,number.boiler_fan,6,0,1,249,1 +"Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i",boiler,172,fanspd,fan speed,uint8,%,false,sensor.boiler_fan_speed,sensor.boiler_fanspd,6,0,1,250,1 +"Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i",boiler,172,shutdown,shutdown,cmd [off\|on] (>=0<=0), ,true,sensor.boiler_shutdown,sensor.boiler_shutdown,6,0,1,251,1 +"Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i",boiler,172,hpcurrpower,compressor current power,uint16,W,false,sensor.boiler_compressor_current_power,sensor.boiler_hpcurrpower,6,0,1,252,1 +"Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i",boiler,172,hppowerlimit,power limit,uint16 (>=0<=0),W,true,number.boiler_power_limit,number.boiler_hppowerlimit,6,0,1,253,1 "Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i",boiler,172,dhw.alternatingop,alternating operation,boolean (>=0<=0), ,true,switch.boiler_dhw_alternating_operation,switch.boiler_dhw_alternatingop,6,9,1,15,1 "Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i",boiler,172,dhw.altopprioheat,prioritise heating during dhw,uint8 (>=20<=120),minutes,true,number.boiler_dhw_prioritise_heating_during_dhw,number.boiler_dhw_altopprioheat,6,9,1,16,1 "Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i",boiler,172,dhw.altopprio,prioritise dhw during heating,uint8 (>=30<=120),minutes,true,number.boiler_dhw_prioritise_dhw_during_heating,number.boiler_dhw_altopprio,6,9,1,17,1 @@ -2875,130 +2897,131 @@ device name,device type,product id,shortname,fullname,type [options...] \| (min/ "Geo 5xx",boiler,173,maintenancedate,next maintenance date,string (>=0<=0), ,true,sensor.boiler_next_maintenance_date,sensor.boiler_maintenancedate,6,0,1,72,6 "Geo 5xx",boiler,173,emergencyops,emergency operation,boolean (>=0<=0), ,true,switch.boiler_emergency_operation,switch.boiler_emergencyops,6,0,1,78,1 "Geo 5xx",boiler,173,emergencytemp,emergency temperature,uint8 (>=15<=70),C,true,number.boiler_emergency_temperature,number.boiler_emergencytemp,6,0,1,79,1 -"Geo 5xx",boiler,173,pc0flow,Flow PC0,int16,l/h,false,sensor.boiler_Flow_PC0,sensor.boiler_pc0flow,6,0,1,80,1 -"Geo 5xx",boiler,173,pc1flow,Flow PC1,int16,l/h,false,sensor.boiler_Flow_PC1,sensor.boiler_pc1flow,6,0,1,81,1 -"Geo 5xx",boiler,173,pc1on,PC1,boolean, ,false,binary_sensor.boiler_PC1,binary_sensor.boiler_pc1on,6,0,1,82,1 -"Geo 5xx",boiler,173,pc1rate,PC1 rate,uint8,%,false,sensor.boiler_PC1_rate,sensor.boiler_pc1rate,6,0,1,83,1 -"Geo 5xx",boiler,173,pumpkickhour,pump kick hour,uint8 (>=0<=23),hours,true,number.boiler_pump_kick_hour,number.boiler_pumpkickhour,6,0,1,84,1 -"Geo 5xx",boiler,173,pumpkickday,pump kick day,enum [mo\|tu\|we\|th\|fr\|sa\|su\|all] (>=0<=0), ,true,select.boiler_pump_kick_day,select.boiler_pumpkickday,6,0,1,85,1 -"Geo 5xx",boiler,173,pumpkickdelay,pump kick delay,uint16 (>=0<=32767),minutes,true,number.boiler_pump_kick_delay,number.boiler_pumpkickdelay,6,0,1,86,1 -"Geo 5xx",boiler,173,mandefrost,manual defrost,cmd [off\|on] (>=0<=0), ,true,sensor.boiler_manual_defrost,sensor.boiler_mandefrost,6,0,1,87,1 -"Geo 5xx",boiler,173,nrgtotal,total energy,uint24,kWh,false,sensor.boiler_total_energy,sensor.boiler_nrgtotal,6,0,1/100,88,2 +"Geo 5xx",boiler,173,pc0lpm,Flow PC0,uint16,l/min,false,sensor.boiler_Flow_PC0,sensor.boiler_pc0lpm,6,0,1/10,80,1 +"Geo 5xx",boiler,173,pc0flow,Flow PC0,uint16,l/h,false,sensor.boiler_Flow_PC0,sensor.boiler_pc0flow,6,0,1,81,1 +"Geo 5xx",boiler,173,pc1flow,Flow PC1,uint16,l/h,false,sensor.boiler_Flow_PC1,sensor.boiler_pc1flow,6,0,1,82,1 +"Geo 5xx",boiler,173,pc1on,PC1,boolean, ,false,binary_sensor.boiler_PC1,binary_sensor.boiler_pc1on,6,0,1,83,1 +"Geo 5xx",boiler,173,pc1rate,PC1 rate,uint8,%,false,sensor.boiler_PC1_rate,sensor.boiler_pc1rate,6,0,1,84,1 +"Geo 5xx",boiler,173,pumpkickhour,pump kick hour,uint8 (>=0<=23),hours,true,number.boiler_pump_kick_hour,number.boiler_pumpkickhour,6,0,1,85,1 +"Geo 5xx",boiler,173,pumpkickday,pump kick day,enum [mo\|tu\|we\|th\|fr\|sa\|su\|all] (>=0<=0), ,true,select.boiler_pump_kick_day,select.boiler_pumpkickday,6,0,1,86,1 +"Geo 5xx",boiler,173,pumpkickdelay,pump kick delay,uint16 (>=0<=32767),minutes,true,number.boiler_pump_kick_delay,number.boiler_pumpkickdelay,6,0,1,87,1 +"Geo 5xx",boiler,173,mandefrost,manual defrost,cmd [off\|on] (>=0<=0), ,true,sensor.boiler_manual_defrost,sensor.boiler_mandefrost,6,0,1,88,1 +"Geo 5xx",boiler,173,nrgtotal,total energy,uint24,kWh,false,sensor.boiler_total_energy,sensor.boiler_nrgtotal,6,0,1/100,89,2 "Geo 5xx",boiler,173,dhw.nrg,energy,uint24,kWh,false,sensor.boiler_dhw_energy,sensor.boiler_dhw_nrg,6,9,1/100,0,2 -"Geo 5xx",boiler,173,nrgheat,energy heating,uint24,kWh,false,sensor.boiler_energy_heating,sensor.boiler_nrgheat,6,0,1/100,90,2 -"Geo 5xx",boiler,173,nrgcool,energy cooling,uint24,kWh,false,sensor.boiler_energy_cooling,sensor.boiler_nrgcool,6,0,1/100,92,2 -"Geo 5xx",boiler,173,metertotal,meter total,uint24,kWh,false,sensor.boiler_meter_total,sensor.boiler_metertotal,6,0,1/100,94,2 -"Geo 5xx",boiler,173,metercomp,meter compressor,uint24,kWh,false,sensor.boiler_meter_compressor,sensor.boiler_metercomp,6,0,1/100,96,2 -"Geo 5xx",boiler,173,metereheat,meter e-heater,uint24,kWh,false,sensor.boiler_meter_e-heater,sensor.boiler_metereheat,6,0,1/100,98,2 -"Geo 5xx",boiler,173,meterheat,meter heating,uint24,kWh,false,sensor.boiler_meter_heating,sensor.boiler_meterheat,6,0,1/100,100,2 -"Geo 5xx",boiler,173,metercool,meter cooling,uint24,kWh,false,sensor.boiler_meter_cooling,sensor.boiler_metercool,6,0,1/100,102,2 +"Geo 5xx",boiler,173,nrgheat,energy heating,uint24,kWh,false,sensor.boiler_energy_heating,sensor.boiler_nrgheat,6,0,1/100,91,2 +"Geo 5xx",boiler,173,nrgcool,energy cooling,uint24,kWh,false,sensor.boiler_energy_cooling,sensor.boiler_nrgcool,6,0,1/100,93,2 +"Geo 5xx",boiler,173,metertotal,meter total,uint24,kWh,false,sensor.boiler_meter_total,sensor.boiler_metertotal,6,0,1/100,95,2 +"Geo 5xx",boiler,173,metercomp,meter compressor,uint24,kWh,false,sensor.boiler_meter_compressor,sensor.boiler_metercomp,6,0,1/100,97,2 +"Geo 5xx",boiler,173,metereheat,meter e-heater,uint24,kWh,false,sensor.boiler_meter_e-heater,sensor.boiler_metereheat,6,0,1/100,99,2 +"Geo 5xx",boiler,173,meterheat,meter heating,uint24,kWh,false,sensor.boiler_meter_heating,sensor.boiler_meterheat,6,0,1/100,101,2 +"Geo 5xx",boiler,173,metercool,meter cooling,uint24,kWh,false,sensor.boiler_meter_cooling,sensor.boiler_metercool,6,0,1/100,103,2 "Geo 5xx",boiler,173,dhw.meter,meter,uint24,kWh,false,sensor.boiler_dhw_meter,sensor.boiler_dhw_meter,6,9,1/100,2,2 -"Geo 5xx",boiler,173,uptimetotal,heatpump total uptime,time,minutes,false,sensor.boiler_heatpump_total_uptime,sensor.boiler_uptimetotal,6,0,1/60,104,2 -"Geo 5xx",boiler,173,uptimecontrol,total operating time heat,time,minutes,false,sensor.boiler_total_operating_time_heat,sensor.boiler_uptimecontrol,6,0,1/60,106,2 -"Geo 5xx",boiler,173,uptimecompheating,operating time compressor heating,time,minutes,false,sensor.boiler_operating_time_compressor_heating,sensor.boiler_uptimecompheating,6,0,1/60,108,2 -"Geo 5xx",boiler,173,uptimecompcooling,operating time compressor cooling,time,minutes,false,sensor.boiler_operating_time_compressor_cooling,sensor.boiler_uptimecompcooling,6,0,1/60,110,2 +"Geo 5xx",boiler,173,uptimetotal,heatpump total uptime,time,minutes,false,sensor.boiler_heatpump_total_uptime,sensor.boiler_uptimetotal,6,0,1/60,105,2 +"Geo 5xx",boiler,173,uptimecontrol,total operating time heat,time,minutes,false,sensor.boiler_total_operating_time_heat,sensor.boiler_uptimecontrol,6,0,1/60,107,2 +"Geo 5xx",boiler,173,uptimecompheating,operating time compressor heating,time,minutes,false,sensor.boiler_operating_time_compressor_heating,sensor.boiler_uptimecompheating,6,0,1/60,109,2 +"Geo 5xx",boiler,173,uptimecompcooling,operating time compressor cooling,time,minutes,false,sensor.boiler_operating_time_compressor_cooling,sensor.boiler_uptimecompcooling,6,0,1/60,111,2 "Geo 5xx",boiler,173,dhw.uptimecomp,operating time compressor,time,minutes,false,sensor.boiler_dhw_operating_time_compressor,sensor.boiler_dhw_uptimecomp,6,9,1/60,4,2 -"Geo 5xx",boiler,173,uptimecomppool,operating time compressor pool,time,minutes,false,sensor.boiler_operating_time_compressor_pool,sensor.boiler_uptimecomppool,6,0,1/60,112,2 -"Geo 5xx",boiler,173,totalcompstarts,total compressor control starts,uint24, ,false,sensor.boiler_total_compressor_control_starts,sensor.boiler_totalcompstarts,6,0,1,114,2 -"Geo 5xx",boiler,173,heatingstarts,heating control starts,uint24, ,false,sensor.boiler_heating_control_starts,sensor.boiler_heatingstarts,6,0,1,116,2 -"Geo 5xx",boiler,173,coolingstarts,cooling control starts,uint24, ,false,sensor.boiler_cooling_control_starts,sensor.boiler_coolingstarts,6,0,1,118,2 +"Geo 5xx",boiler,173,uptimecomppool,operating time compressor pool,time,minutes,false,sensor.boiler_operating_time_compressor_pool,sensor.boiler_uptimecomppool,6,0,1/60,113,2 +"Geo 5xx",boiler,173,totalcompstarts,total compressor control starts,uint24, ,false,sensor.boiler_total_compressor_control_starts,sensor.boiler_totalcompstarts,6,0,1,115,2 +"Geo 5xx",boiler,173,heatingstarts,heating control starts,uint24, ,false,sensor.boiler_heating_control_starts,sensor.boiler_heatingstarts,6,0,1,117,2 +"Geo 5xx",boiler,173,coolingstarts,cooling control starts,uint24, ,false,sensor.boiler_cooling_control_starts,sensor.boiler_coolingstarts,6,0,1,119,2 "Geo 5xx",boiler,173,dhw.startshp,starts hp,uint24, ,false,sensor.boiler_dhw_starts_hp,sensor.boiler_dhw_startshp,6,9,1,6,2 -"Geo 5xx",boiler,173,poolstarts,pool control starts,uint24, ,false,sensor.boiler_pool_control_starts,sensor.boiler_poolstarts,6,0,1,120,2 -"Geo 5xx",boiler,173,nrgconstotal,total energy consumption,uint24,kWh,false,sensor.boiler_total_energy_consumption,sensor.boiler_nrgconstotal,6,0,1,122,2 -"Geo 5xx",boiler,173,nrgconscomptotal,total energy consumption compressor,uint24,kWh,false,sensor.boiler_total_energy_consumption_compressor,sensor.boiler_nrgconscomptotal,6,0,1,124,2 -"Geo 5xx",boiler,173,nrgconscompheating,energy consumption compressor heating,uint24,kWh,false,sensor.boiler_energy_consumption_compressor_heating,sensor.boiler_nrgconscompheating,6,0,1,126,2 +"Geo 5xx",boiler,173,poolstarts,pool control starts,uint24, ,false,sensor.boiler_pool_control_starts,sensor.boiler_poolstarts,6,0,1,121,2 +"Geo 5xx",boiler,173,nrgconstotal,total energy consumption,uint24,kWh,false,sensor.boiler_total_energy_consumption,sensor.boiler_nrgconstotal,6,0,1,123,2 +"Geo 5xx",boiler,173,nrgconscomptotal,total energy consumption compressor,uint24,kWh,false,sensor.boiler_total_energy_consumption_compressor,sensor.boiler_nrgconscomptotal,6,0,1,125,2 +"Geo 5xx",boiler,173,nrgconscompheating,energy consumption compressor heating,uint24,kWh,false,sensor.boiler_energy_consumption_compressor_heating,sensor.boiler_nrgconscompheating,6,0,1,127,2 "Geo 5xx",boiler,173,dhw.nrgconscomp,energy consumption compressor,uint24,kWh,false,sensor.boiler_dhw_energy_consumption_compressor,sensor.boiler_dhw_nrgconscomp,6,9,1,8,2 -"Geo 5xx",boiler,173,nrgconscompcooling,energy consumption compressor cooling,uint24,kWh,false,sensor.boiler_energy_consumption_compressor_cooling,sensor.boiler_nrgconscompcooling,6,0,1,128,2 -"Geo 5xx",boiler,173,nrgconscomppool,energy consumption compressor pool,uint24,kWh,false,sensor.boiler_energy_consumption_compressor_pool,sensor.boiler_nrgconscomppool,6,0,1,130,2 -"Geo 5xx",boiler,173,auxelecheatnrgconstotal,total aux elec. heater energy consumption,uint24,kWh,false,sensor.boiler_total_aux_elec._heater_energy_consumption,sensor.boiler_auxelecheatnrgconstotal,6,0,1,132,2 -"Geo 5xx",boiler,173,auxelecheatnrgconsheating,aux elec. heater energy consumption heating,uint24,kWh,false,sensor.boiler_aux_elec._heater_energy_consumption_heating,sensor.boiler_auxelecheatnrgconsheating,6,0,1,134,2 +"Geo 5xx",boiler,173,nrgconscompcooling,energy consumption compressor cooling,uint24,kWh,false,sensor.boiler_energy_consumption_compressor_cooling,sensor.boiler_nrgconscompcooling,6,0,1,129,2 +"Geo 5xx",boiler,173,nrgconscomppool,energy consumption compressor pool,uint24,kWh,false,sensor.boiler_energy_consumption_compressor_pool,sensor.boiler_nrgconscomppool,6,0,1,131,2 +"Geo 5xx",boiler,173,auxelecheatnrgconstotal,total aux elec. heater energy consumption,uint24,kWh,false,sensor.boiler_total_aux_elec._heater_energy_consumption,sensor.boiler_auxelecheatnrgconstotal,6,0,1,133,2 +"Geo 5xx",boiler,173,auxelecheatnrgconsheating,aux elec. heater energy consumption heating,uint24,kWh,false,sensor.boiler_aux_elec._heater_energy_consumption_heating,sensor.boiler_auxelecheatnrgconsheating,6,0,1,135,2 "Geo 5xx",boiler,173,dhw.auxelecheatnrgcons,aux elec. heater energy consumption,uint24,kWh,false,sensor.boiler_dhw_aux_elec._heater_energy_consumption,sensor.boiler_dhw_auxelecheatnrgcons,6,9,1,10,2 -"Geo 5xx",boiler,173,auxelecheatnrgconspool,aux elec. heater energy consumption pool,uint24,kWh,false,sensor.boiler_aux_elec._heater_energy_consumption_pool,sensor.boiler_auxelecheatnrgconspool,6,0,1,136,2 -"Geo 5xx",boiler,173,nrgsupptotal,total energy supplied,uint24,kWh,false,sensor.boiler_total_energy_supplied,sensor.boiler_nrgsupptotal,6,0,1,138,2 -"Geo 5xx",boiler,173,nrgsuppheating,total energy supplied heating,uint24,kWh,false,sensor.boiler_total_energy_supplied_heating,sensor.boiler_nrgsuppheating,6,0,1,140,2 +"Geo 5xx",boiler,173,auxelecheatnrgconspool,aux elec. heater energy consumption pool,uint24,kWh,false,sensor.boiler_aux_elec._heater_energy_consumption_pool,sensor.boiler_auxelecheatnrgconspool,6,0,1,137,2 +"Geo 5xx",boiler,173,nrgsupptotal,total energy supplied,uint24,kWh,false,sensor.boiler_total_energy_supplied,sensor.boiler_nrgsupptotal,6,0,1,139,2 +"Geo 5xx",boiler,173,nrgsuppheating,total energy supplied heating,uint24,kWh,false,sensor.boiler_total_energy_supplied_heating,sensor.boiler_nrgsuppheating,6,0,1,141,2 "Geo 5xx",boiler,173,dhw.nrgsupp,total energy warm supplied,uint24,kWh,false,sensor.boiler_dhw_total_energy_warm_supplied,sensor.boiler_dhw_nrgsupp,6,9,1,12,2 -"Geo 5xx",boiler,173,nrgsuppcooling,total energy supplied cooling,uint24,kWh,false,sensor.boiler_total_energy_supplied_cooling,sensor.boiler_nrgsuppcooling,6,0,1,142,2 -"Geo 5xx",boiler,173,nrgsupppool,total energy supplied pool,uint24,kWh,false,sensor.boiler_total_energy_supplied_pool,sensor.boiler_nrgsupppool,6,0,1,144,2 -"Geo 5xx",boiler,173,hppower,compressor power output,uint16,kW,false,sensor.boiler_compressor_power_output,sensor.boiler_hppower,6,0,1/10,146,1 -"Geo 5xx",boiler,173,hpmaxpower,compressor max power,uint8 (>=0<=0),%,true,number.boiler_compressor_max_power,number.boiler_hpmaxpower,6,0,1,147,1 -"Geo 5xx",boiler,173,pvmaxcomp,pv compressor max power,uint8 (>=0<=0),kW,true,number.boiler_pv_compressor_max_power,number.boiler_pvmaxcomp,6,0,1/10,148,1 -"Geo 5xx",boiler,173,powerreduction,power reduction,uint8 (>=30<=60),%,true,number.boiler_power_reduction,number.boiler_powerreduction,6,0,10,149,1 -"Geo 5xx",boiler,173,hpsetdiffpress,set differential pressure,uint8 (>=150<=750),mbar,true,number.boiler_set_differential_pressure,number.boiler_hpsetdiffpress,6,0,50,150,1 -"Geo 5xx",boiler,173,hpcompon,hp compressor,boolean, ,false,binary_sensor.boiler_hp_compressor,binary_sensor.boiler_hpcompon,6,0,1,151,1 -"Geo 5xx",boiler,173,hpactivity,compressor activity,enum [off\|heating\|cooling\|hot water\|pool\|pool heating\|defrost\|compressor alarm], ,false,sensor.boiler_compressor_activity,sensor.boiler_hpactivity,6,0,1,152,1 -"Geo 5xx",boiler,173,hpbrinepumpspd,brine pump speed,uint8,%,false,sensor.boiler_brine_pump_speed,sensor.boiler_hpbrinepumpspd,6,0,1,153,1 -"Geo 5xx",boiler,173,hpswitchvalve,switch valve,boolean, ,false,binary_sensor.boiler_switch_valve,binary_sensor.boiler_hpswitchvalve,6,0,1,154,1 -"Geo 5xx",boiler,173,hpcompspd,compressor speed,uint8,%,false,sensor.boiler_compressor_speed,sensor.boiler_hpcompspd,6,0,1,155,1 -"Geo 5xx",boiler,173,hptargetspd,compressor target speed,uint8,%,false,sensor.boiler_compressor_target_speed,sensor.boiler_hptargetspd,6,0,1,156,1 -"Geo 5xx",boiler,173,hpcircspd,circulation pump speed,uint8,%,false,sensor.boiler_circulation_pump_speed,sensor.boiler_hpcircspd,6,0,1,157,1 -"Geo 5xx",boiler,173,recvalve,receiver valve VR0,uint8,%,false,sensor.boiler_receiver_valve_VR0,sensor.boiler_recvalve,6,0,1,158,1 -"Geo 5xx",boiler,173,expvalve,expansion valve VR1,uint8,%,false,sensor.boiler_expansion_valve_VR1,sensor.boiler_expvalve,6,0,1,159,1 -"Geo 5xx",boiler,173,hpbrinein,brine in/evaporator,int16,C,false,sensor.boiler_brine_in/evaporator,sensor.boiler_hpbrinein,6,0,1/10,160,1 -"Geo 5xx",boiler,173,hpbrineout,brine out/condenser,int16,C,false,sensor.boiler_brine_out/condenser,sensor.boiler_hpbrineout,6,0,1/10,161,1 -"Geo 5xx",boiler,173,hptc0,heat carrier return (TC0),int16,C,false,sensor.boiler_heat_carrier_return_(TC0),sensor.boiler_hptc0,6,0,1/10,162,1 -"Geo 5xx",boiler,173,hptc1,heat carrier forward (TC1),int16,C,false,sensor.boiler_heat_carrier_forward_(TC1),sensor.boiler_hptc1,6,0,1/10,163,1 -"Geo 5xx",boiler,173,hptc3,condenser temperature (TC3),int16,C,false,sensor.boiler_condenser_temperature_(TC3),sensor.boiler_hptc3,6,0,1/10,164,1 -"Geo 5xx",boiler,173,hptr1,compressor temperature (TR1),int16,C,false,sensor.boiler_compressor_temperature_(TR1),sensor.boiler_hptr1,6,0,1/10,165,1 -"Geo 5xx",boiler,173,hptr3,refrigerant temperature liquid side (condenser output) (TR3),int16,C,false,sensor.boiler_refrigerant_temperature_liquid_side_(condenser_output)_(TR3),sensor.boiler_hptr3,6,0,1/10,166,1 -"Geo 5xx",boiler,173,hptr4,evaporator inlet temperature (TR4),int16,C,false,sensor.boiler_evaporator_inlet_temperature_(TR4),sensor.boiler_hptr4,6,0,1/10,167,1 -"Geo 5xx",boiler,173,hptr5,compressor inlet temperature (TR5),int16,C,false,sensor.boiler_compressor_inlet_temperature_(TR5),sensor.boiler_hptr5,6,0,1/10,168,1 -"Geo 5xx",boiler,173,hptr6,compressor outlet temperature (TR6),int16,C,false,sensor.boiler_compressor_outlet_temperature_(TR6),sensor.boiler_hptr6,6,0,1/10,169,1 -"Geo 5xx",boiler,173,hptr7,refrigerant temperature gas side (condenser input) (TR7),int16,C,false,sensor.boiler_refrigerant_temperature_gas_side_(condenser_input)_(TR7),sensor.boiler_hptr7,6,0,1/10,170,1 -"Geo 5xx",boiler,173,hptl2,air inlet temperature (TL2),int16,C,false,sensor.boiler_air_inlet_temperature_(TL2),sensor.boiler_hptl2,6,0,1/10,171,1 -"Geo 5xx",boiler,173,hppl1,low pressure side temperature (PL1),int16,C,false,sensor.boiler_low_pressure_side_temperature_(PL1),sensor.boiler_hppl1,6,0,1/10,172,1 -"Geo 5xx",boiler,173,hpph1,high pressure side temperature (PH1),int16,C,false,sensor.boiler_high_pressure_side_temperature_(PH1),sensor.boiler_hpph1,6,0,1/10,173,1 -"Geo 5xx",boiler,173,hpta4,drain pan temp (TA4),int16,C,false,sensor.boiler_drain_pan_temp_(TA4),sensor.boiler_hpta4,6,0,1/10,174,1 -"Geo 5xx",boiler,173,hptw1,reservoir temp (TW1),int16,C,false,sensor.boiler_reservoir_temp_(TW1),sensor.boiler_hptw1,6,0,1/10,175,1 -"Geo 5xx",boiler,173,poolsettemp,pool set temperature,uint8 (>=0<=0),C,true,number.boiler_pool_set_temperature,number.boiler_poolsettemp,6,0,1/2,176,1 -"Geo 5xx",boiler,173,hp4way,4-way valve (VR4),boolean, ,false,binary_sensor.boiler_4-way_valve_(VR4),binary_sensor.boiler_hp4way,6,0,1,177,1 -"Geo 5xx",boiler,173,hpin1,input 1 state,boolean, ,false,binary_sensor.boiler_input_1_state,binary_sensor.boiler_hpin1,6,0,1,178,1 -"Geo 5xx",boiler,173,hpin1opt,input 1 options,string (>=0<=0), ,true,sensor.boiler_input_1_options,sensor.boiler_hpin1opt,6,0,1,179,8 -"Geo 5xx",boiler,173,hpin2,input 2 state,boolean, ,false,binary_sensor.boiler_input_2_state,binary_sensor.boiler_hpin2,6,0,1,187,1 -"Geo 5xx",boiler,173,hpin2opt,input 2 options,string (>=0<=0), ,true,sensor.boiler_input_2_options,sensor.boiler_hpin2opt,6,0,1,188,8 -"Geo 5xx",boiler,173,hpin3,input 3 state,boolean, ,false,binary_sensor.boiler_input_3_state,binary_sensor.boiler_hpin3,6,0,1,196,1 -"Geo 5xx",boiler,173,hpin3opt,input 3 options,string (>=0<=0), ,true,sensor.boiler_input_3_options,sensor.boiler_hpin3opt,6,0,1,197,8 -"Geo 5xx",boiler,173,hpin4,input 4 state,boolean, ,false,binary_sensor.boiler_input_4_state,binary_sensor.boiler_hpin4,6,0,1,205,1 -"Geo 5xx",boiler,173,hpin4opt,input 4 options,string (>=0<=0), ,true,sensor.boiler_input_4_options,sensor.boiler_hpin4opt,6,0,1,206,8 -"Geo 5xx",boiler,173,maxheatcomp,heat limit compressor,enum [0 kW\|2 kW\|3 kW\|4 kW\|6 kW\|9 kW] (>=0<=0), ,true,select.boiler_heat_limit_compressor,select.boiler_maxheatcomp,6,0,1,214,1 -"Geo 5xx",boiler,173,maxheatheat,heat limit heating,enum [0 kW\|2 kW\|3 kW\|4 kW\|6 kW\|9 kW] (>=0<=0), ,true,select.boiler_heat_limit_heating,select.boiler_maxheatheat,6,0,1,215,1 +"Geo 5xx",boiler,173,nrgsuppcooling,total energy supplied cooling,uint24,kWh,false,sensor.boiler_total_energy_supplied_cooling,sensor.boiler_nrgsuppcooling,6,0,1,143,2 +"Geo 5xx",boiler,173,nrgsupppool,total energy supplied pool,uint24,kWh,false,sensor.boiler_total_energy_supplied_pool,sensor.boiler_nrgsupppool,6,0,1,145,2 +"Geo 5xx",boiler,173,hppower,compressor power output,uint16,kW,false,sensor.boiler_compressor_power_output,sensor.boiler_hppower,6,0,1/10,147,1 +"Geo 5xx",boiler,173,hpmaxpower,compressor max power,uint8 (>=0<=0),%,true,number.boiler_compressor_max_power,number.boiler_hpmaxpower,6,0,1,148,1 +"Geo 5xx",boiler,173,pvmaxcomp,pv compressor max power,uint8 (>=0<=0),kW,true,number.boiler_pv_compressor_max_power,number.boiler_pvmaxcomp,6,0,1/10,149,1 +"Geo 5xx",boiler,173,powerreduction,power reduction,uint8 (>=30<=60),%,true,number.boiler_power_reduction,number.boiler_powerreduction,6,0,10,150,1 +"Geo 5xx",boiler,173,hpsetdiffpress,set differential pressure,uint8 (>=150<=750),mbar,true,number.boiler_set_differential_pressure,number.boiler_hpsetdiffpress,6,0,50,151,1 +"Geo 5xx",boiler,173,hpcompon,hp compressor,boolean, ,false,binary_sensor.boiler_hp_compressor,binary_sensor.boiler_hpcompon,6,0,1,152,1 +"Geo 5xx",boiler,173,hpactivity,compressor activity,enum [off\|heating\|cooling\|hot water\|pool\|pool heating\|defrost\|compressor alarm], ,false,sensor.boiler_compressor_activity,sensor.boiler_hpactivity,6,0,1,153,1 +"Geo 5xx",boiler,173,hpbrinepumpspd,brine pump speed,uint8,%,false,sensor.boiler_brine_pump_speed,sensor.boiler_hpbrinepumpspd,6,0,1,154,1 +"Geo 5xx",boiler,173,hpswitchvalve,switch valve,boolean, ,false,binary_sensor.boiler_switch_valve,binary_sensor.boiler_hpswitchvalve,6,0,1,155,1 +"Geo 5xx",boiler,173,hpcompspd,compressor speed,uint8,%,false,sensor.boiler_compressor_speed,sensor.boiler_hpcompspd,6,0,1,156,1 +"Geo 5xx",boiler,173,hptargetspd,compressor target speed,uint8,%,false,sensor.boiler_compressor_target_speed,sensor.boiler_hptargetspd,6,0,1,157,1 +"Geo 5xx",boiler,173,hpcircspd,circulation pump speed,uint8,%,false,sensor.boiler_circulation_pump_speed,sensor.boiler_hpcircspd,6,0,1,158,1 +"Geo 5xx",boiler,173,recvalve,receiver valve VR0,uint8,%,false,sensor.boiler_receiver_valve_VR0,sensor.boiler_recvalve,6,0,1,159,1 +"Geo 5xx",boiler,173,expvalve,expansion valve VR1,uint8,%,false,sensor.boiler_expansion_valve_VR1,sensor.boiler_expvalve,6,0,1,160,1 +"Geo 5xx",boiler,173,hpbrinein,brine in/evaporator,int16,C,false,sensor.boiler_brine_in/evaporator,sensor.boiler_hpbrinein,6,0,1/10,161,1 +"Geo 5xx",boiler,173,hpbrineout,brine out/condenser,int16,C,false,sensor.boiler_brine_out/condenser,sensor.boiler_hpbrineout,6,0,1/10,162,1 +"Geo 5xx",boiler,173,hptc0,heat carrier return (TC0),int16,C,false,sensor.boiler_heat_carrier_return_(TC0),sensor.boiler_hptc0,6,0,1/10,163,1 +"Geo 5xx",boiler,173,hptc1,heat carrier forward (TC1),int16,C,false,sensor.boiler_heat_carrier_forward_(TC1),sensor.boiler_hptc1,6,0,1/10,164,1 +"Geo 5xx",boiler,173,hptc3,condenser temperature (TC3),int16,C,false,sensor.boiler_condenser_temperature_(TC3),sensor.boiler_hptc3,6,0,1/10,165,1 +"Geo 5xx",boiler,173,hptr1,compressor temperature (TR1),int16,C,false,sensor.boiler_compressor_temperature_(TR1),sensor.boiler_hptr1,6,0,1/10,166,1 +"Geo 5xx",boiler,173,hptr3,refrigerant temperature liquid side (condenser output) (TR3),int16,C,false,sensor.boiler_refrigerant_temperature_liquid_side_(condenser_output)_(TR3),sensor.boiler_hptr3,6,0,1/10,167,1 +"Geo 5xx",boiler,173,hptr4,evaporator inlet temperature (TR4),int16,C,false,sensor.boiler_evaporator_inlet_temperature_(TR4),sensor.boiler_hptr4,6,0,1/10,168,1 +"Geo 5xx",boiler,173,hptr5,compressor inlet temperature (TR5),int16,C,false,sensor.boiler_compressor_inlet_temperature_(TR5),sensor.boiler_hptr5,6,0,1/10,169,1 +"Geo 5xx",boiler,173,hptr6,compressor outlet temperature (TR6),int16,C,false,sensor.boiler_compressor_outlet_temperature_(TR6),sensor.boiler_hptr6,6,0,1/10,170,1 +"Geo 5xx",boiler,173,hptr7,refrigerant temperature gas side (condenser input) (TR7),int16,C,false,sensor.boiler_refrigerant_temperature_gas_side_(condenser_input)_(TR7),sensor.boiler_hptr7,6,0,1/10,171,1 +"Geo 5xx",boiler,173,hptl2,air inlet temperature (TL2),int16,C,false,sensor.boiler_air_inlet_temperature_(TL2),sensor.boiler_hptl2,6,0,1/10,172,1 +"Geo 5xx",boiler,173,hppl1,low pressure side temperature (PL1),int16,C,false,sensor.boiler_low_pressure_side_temperature_(PL1),sensor.boiler_hppl1,6,0,1/10,173,1 +"Geo 5xx",boiler,173,hpph1,high pressure side temperature (PH1),int16,C,false,sensor.boiler_high_pressure_side_temperature_(PH1),sensor.boiler_hpph1,6,0,1/10,174,1 +"Geo 5xx",boiler,173,hpta4,drain pan temp (TA4),int16,C,false,sensor.boiler_drain_pan_temp_(TA4),sensor.boiler_hpta4,6,0,1/10,175,1 +"Geo 5xx",boiler,173,hptw1,reservoir temp (TW1),int16,C,false,sensor.boiler_reservoir_temp_(TW1),sensor.boiler_hptw1,6,0,1/10,176,1 +"Geo 5xx",boiler,173,poolsettemp,pool set temperature,uint8 (>=0<=0),C,true,number.boiler_pool_set_temperature,number.boiler_poolsettemp,6,0,1/2,177,1 +"Geo 5xx",boiler,173,hp4way,4-way valve (VR4),boolean, ,false,binary_sensor.boiler_4-way_valve_(VR4),binary_sensor.boiler_hp4way,6,0,1,178,1 +"Geo 5xx",boiler,173,hpin1,input 1 state,boolean, ,false,binary_sensor.boiler_input_1_state,binary_sensor.boiler_hpin1,6,0,1,179,1 +"Geo 5xx",boiler,173,hpin1opt,input 1 options,string (>=0<=0), ,true,sensor.boiler_input_1_options,sensor.boiler_hpin1opt,6,0,1,180,8 +"Geo 5xx",boiler,173,hpin2,input 2 state,boolean, ,false,binary_sensor.boiler_input_2_state,binary_sensor.boiler_hpin2,6,0,1,188,1 +"Geo 5xx",boiler,173,hpin2opt,input 2 options,string (>=0<=0), ,true,sensor.boiler_input_2_options,sensor.boiler_hpin2opt,6,0,1,189,8 +"Geo 5xx",boiler,173,hpin3,input 3 state,boolean, ,false,binary_sensor.boiler_input_3_state,binary_sensor.boiler_hpin3,6,0,1,197,1 +"Geo 5xx",boiler,173,hpin3opt,input 3 options,string (>=0<=0), ,true,sensor.boiler_input_3_options,sensor.boiler_hpin3opt,6,0,1,198,8 +"Geo 5xx",boiler,173,hpin4,input 4 state,boolean, ,false,binary_sensor.boiler_input_4_state,binary_sensor.boiler_hpin4,6,0,1,206,1 +"Geo 5xx",boiler,173,hpin4opt,input 4 options,string (>=0<=0), ,true,sensor.boiler_input_4_options,sensor.boiler_hpin4opt,6,0,1,207,8 +"Geo 5xx",boiler,173,maxheatcomp,heat limit compressor,enum [0 kW\|2 kW\|3 kW\|4 kW\|6 kW\|9 kW] (>=0<=0), ,true,select.boiler_heat_limit_compressor,select.boiler_maxheatcomp,6,0,1,215,1 +"Geo 5xx",boiler,173,maxheatheat,heat limit heating,enum [0 kW\|2 kW\|3 kW\|4 kW\|6 kW\|9 kW] (>=0<=0), ,true,select.boiler_heat_limit_heating,select.boiler_maxheatheat,6,0,1,216,1 "Geo 5xx",boiler,173,dhw.maxheat,heat limit,enum [0 kW\|2 kW\|3 kW\|4 kW\|6 kW\|9 kW] (>=0<=0), ,true,select.boiler_dhw_heat_limit,select.boiler_dhw_maxheat,6,9,1,14,1 -"Geo 5xx",boiler,173,auxheatersource,aux heater source,enum [not installed\|electric heater\|exclusive\|parallel\|hybrid] (>=0<=0), ,true,select.boiler_aux_heater_source,select.boiler_auxheatersource,6,0,1,216,1 -"Geo 5xx",boiler,173,pvcooling,cooling only with PV,boolean (>=0<=0), ,true,switch.boiler_cooling_only_with_PV,switch.boiler_pvcooling,6,0,1,217,1 -"Geo 5xx",boiler,173,auxheateronly,aux heater only,boolean (>=0<=0), ,true,switch.boiler_aux_heater_only,switch.boiler_auxheateronly,6,0,1,218,1 -"Geo 5xx",boiler,173,auxheateroff,disable aux heater,boolean (>=0<=0), ,true,switch.boiler_disable_aux_heater,switch.boiler_auxheateroff,6,0,1,219,1 -"Geo 5xx",boiler,173,auxheaterstatus,aux heater status,enum [off\|heating\|cooling\|hot water\|pool\|pool heating\|defrost\|compressor alarm], ,false,sensor.boiler_aux_heater_status,sensor.boiler_auxheaterstatus,6,0,1,220,1 -"Geo 5xx",boiler,173,auxheaterlevel,aux heater level,uint8,%,false,sensor.boiler_aux_heater_level,sensor.boiler_auxheaterlevel,6,0,1,221,1 -"Geo 5xx",boiler,173,auxheaterdelay,aux heater on delay,uint16 (>=10<=1000),K*min,true,number.boiler_aux_heater_on_delay,number.boiler_auxheaterdelay,6,0,10,222,1 -"Geo 5xx",boiler,173,auxmaxlimit,aux heater max limit,uint8 (>=0<=10),K,true,number.boiler_aux_heater_max_limit,number.boiler_auxmaxlimit,6,0,1/10,223,1 -"Geo 5xx",boiler,173,auxlimitstart,aux heater limit start,uint8 (>=0<=10),K,true,number.boiler_aux_heater_limit_start,number.boiler_auxlimitstart,6,0,1/10,224,1 -"Geo 5xx",boiler,173,auxheatrmode,aux heater mode,enum [eco\|comfort] (>=0<=0), ,true,select.boiler_aux_heater_mode,select.boiler_auxheatrmode,6,0,1,225,1 -"Geo 5xx",boiler,173,hphystheat,on/off hyst heat,uint16 (>=50<=1500),K*min,true,number.boiler_on/off_hyst_heat,number.boiler_hphystheat,6,0,5,226,1 -"Geo 5xx",boiler,173,hphystcool,on/off hyst cool,uint16 (>=50<=1500),K*min,true,number.boiler_on/off_hyst_cool,number.boiler_hphystcool,6,0,5,227,1 -"Geo 5xx",boiler,173,hphystpool,on/off hyst pool,uint16 (>=50<=1500),K*min,true,number.boiler_on/off_hyst_pool,number.boiler_hphystpool,6,0,5,228,1 -"Geo 5xx",boiler,173,silentmode,silent mode,enum [off\|auto\|on] (>=0<=0), ,true,select.boiler_silent_mode,select.boiler_silentmode,6,0,1,229,1 -"Geo 5xx",boiler,173,silentfrom,silent mode from,uint8 (>=0<=0),minutes,true,number.boiler_silent_mode_from,number.boiler_silentfrom,6,0,15,230,1 -"Geo 5xx",boiler,173,silentto,silent mode to,uint8 (>=0<=0),minutes,true,number.boiler_silent_mode_to,number.boiler_silentto,6,0,15,231,1 -"Geo 5xx",boiler,173,mintempsilent,min outside temp for silent mode,int8 (>=0<=0),C,true,number.boiler_min_outside_temp_for_silent_mode,number.boiler_mintempsilent,6,0,1,232,1 -"Geo 5xx",boiler,173,tempparmode,outside temp parallel mode,int8 (>=0<=0),C,true,number.boiler_outside_temp_parallel_mode,number.boiler_tempparmode,6,0,1,233,1 -"Geo 5xx",boiler,173,auxheatmix,aux heater mixing valve,int8,%,false,sensor.boiler_aux_heater_mixing_valve,sensor.boiler_auxheatmix,6,0,1,234,1 -"Geo 5xx",boiler,173,tempdiffheat,temp diff TC3/TC0 heat,uint8 (>=2<=10),K,true,number.boiler_temp_diff_TC3/TC0_heat,number.boiler_tempdiffheat,6,0,1/10,235,1 -"Geo 5xx",boiler,173,tempdiffcool,temp diff TC3/TC0 cool,uint8 (>=2<=10),K,true,number.boiler_temp_diff_TC3/TC0_cool,number.boiler_tempdiffcool,6,0,1/10,236,1 -"Geo 5xx",boiler,173,vpcooling,valve/pump cooling,boolean (>=0<=0), ,true,switch.boiler_valve/pump_cooling,switch.boiler_vpcooling,6,0,1,237,1 -"Geo 5xx",boiler,173,heatcable,heating cable,boolean (>=0<=0), ,true,switch.boiler_heating_cable,switch.boiler_heatcable,6,0,1,238,1 -"Geo 5xx",boiler,173,vc0valve,VC0 valve,boolean (>=0<=0), ,true,switch.boiler_VC0_valve,switch.boiler_vc0valve,6,0,1,239,1 -"Geo 5xx",boiler,173,primepump,primary heatpump,boolean (>=0<=0), ,true,switch.boiler_primary_heatpump,switch.boiler_primepump,6,0,1,240,1 -"Geo 5xx",boiler,173,primepumpmod,primary heatpump modulation,uint8 (>=0<=0),%,true,number.boiler_primary_heatpump_modulation,number.boiler_primepumpmod,6,0,1,241,1 -"Geo 5xx",boiler,173,hp3way,3-way valve,boolean (>=0<=0), ,true,switch.boiler_3-way_valve,switch.boiler_hp3way,6,0,1,242,1 -"Geo 5xx",boiler,173,elheatstep1,el. heater step 1,boolean (>=0<=0), ,true,switch.boiler_el._heater_step_1,switch.boiler_elheatstep1,6,0,1,243,1 -"Geo 5xx",boiler,173,elheatstep2,el. heater step 2,boolean (>=0<=0), ,true,switch.boiler_el._heater_step_2,switch.boiler_elheatstep2,6,0,1,244,1 -"Geo 5xx",boiler,173,elheatstep3,el. heater step 3,boolean (>=0<=0), ,true,switch.boiler_el._heater_step_3,switch.boiler_elheatstep3,6,0,1,245,1 -"Geo 5xx",boiler,173,hpea0,condensate reservoir heating (EA0),boolean, ,false,binary_sensor.boiler_condensate_reservoir_heating_(EA0),binary_sensor.boiler_hpea0,6,0,1,246,1 -"Geo 5xx",boiler,173,hppumpmode,primary heatpump mode,enum [auto\|continuous] (>=0<=0), ,true,select.boiler_primary_heatpump_mode,select.boiler_hppumpmode,6,0,1,247,1 -"Geo 5xx",boiler,173,fan,fan,uint8 (>=20<=100),%,true,number.boiler_fan,number.boiler_fan,6,0,1,248,1 -"Geo 5xx",boiler,173,fanspd,fan speed,uint8,%,false,sensor.boiler_fan_speed,sensor.boiler_fanspd,6,0,1,249,1 -"Geo 5xx",boiler,173,shutdown,shutdown,cmd [off\|on] (>=0<=0), ,true,sensor.boiler_shutdown,sensor.boiler_shutdown,6,0,1,250,1 -"Geo 5xx",boiler,173,hpcurrpower,compressor current power,uint16,W,false,sensor.boiler_compressor_current_power,sensor.boiler_hpcurrpower,6,0,1,251,1 -"Geo 5xx",boiler,173,hppowerlimit,power limit,uint16 (>=0<=0),W,true,number.boiler_power_limit,number.boiler_hppowerlimit,6,0,1,252,1 +"Geo 5xx",boiler,173,auxheatersource,aux heater source,enum [not installed\|electric heater\|exclusive\|parallel\|hybrid] (>=0<=0), ,true,select.boiler_aux_heater_source,select.boiler_auxheatersource,6,0,1,217,1 +"Geo 5xx",boiler,173,pvcooling,cooling only with PV,boolean (>=0<=0), ,true,switch.boiler_cooling_only_with_PV,switch.boiler_pvcooling,6,0,1,218,1 +"Geo 5xx",boiler,173,auxheateronly,aux heater only,boolean (>=0<=0), ,true,switch.boiler_aux_heater_only,switch.boiler_auxheateronly,6,0,1,219,1 +"Geo 5xx",boiler,173,auxheateroff,disable aux heater,boolean (>=0<=0), ,true,switch.boiler_disable_aux_heater,switch.boiler_auxheateroff,6,0,1,220,1 +"Geo 5xx",boiler,173,auxheaterstatus,aux heater status,enum [off\|heating\|cooling\|hot water\|pool\|pool heating\|defrost\|compressor alarm], ,false,sensor.boiler_aux_heater_status,sensor.boiler_auxheaterstatus,6,0,1,221,1 +"Geo 5xx",boiler,173,auxheaterlevel,aux heater level,uint8,%,false,sensor.boiler_aux_heater_level,sensor.boiler_auxheaterlevel,6,0,1,222,1 +"Geo 5xx",boiler,173,auxheaterdelay,aux heater on delay,uint16 (>=10<=1000),K*min,true,number.boiler_aux_heater_on_delay,number.boiler_auxheaterdelay,6,0,10,223,1 +"Geo 5xx",boiler,173,auxmaxlimit,aux heater max limit,uint8 (>=0<=10),K,true,number.boiler_aux_heater_max_limit,number.boiler_auxmaxlimit,6,0,1/10,224,1 +"Geo 5xx",boiler,173,auxlimitstart,aux heater limit start,uint8 (>=0<=10),K,true,number.boiler_aux_heater_limit_start,number.boiler_auxlimitstart,6,0,1/10,225,1 +"Geo 5xx",boiler,173,auxheatrmode,aux heater mode,enum [eco\|comfort] (>=0<=0), ,true,select.boiler_aux_heater_mode,select.boiler_auxheatrmode,6,0,1,226,1 +"Geo 5xx",boiler,173,hphystheat,on/off hyst heat,uint16 (>=50<=1500),K*min,true,number.boiler_on/off_hyst_heat,number.boiler_hphystheat,6,0,5,227,1 +"Geo 5xx",boiler,173,hphystcool,on/off hyst cool,uint16 (>=50<=1500),K*min,true,number.boiler_on/off_hyst_cool,number.boiler_hphystcool,6,0,5,228,1 +"Geo 5xx",boiler,173,hphystpool,on/off hyst pool,uint16 (>=50<=1500),K*min,true,number.boiler_on/off_hyst_pool,number.boiler_hphystpool,6,0,5,229,1 +"Geo 5xx",boiler,173,silentmode,silent mode,enum [off\|auto\|on] (>=0<=0), ,true,select.boiler_silent_mode,select.boiler_silentmode,6,0,1,230,1 +"Geo 5xx",boiler,173,silentfrom,silent mode from,uint8 (>=0<=0),minutes,true,number.boiler_silent_mode_from,number.boiler_silentfrom,6,0,15,231,1 +"Geo 5xx",boiler,173,silentto,silent mode to,uint8 (>=0<=0),minutes,true,number.boiler_silent_mode_to,number.boiler_silentto,6,0,15,232,1 +"Geo 5xx",boiler,173,mintempsilent,min outside temp for silent mode,int8 (>=0<=0),C,true,number.boiler_min_outside_temp_for_silent_mode,number.boiler_mintempsilent,6,0,1,233,1 +"Geo 5xx",boiler,173,tempparmode,outside temp parallel mode,int8 (>=0<=0),C,true,number.boiler_outside_temp_parallel_mode,number.boiler_tempparmode,6,0,1,234,1 +"Geo 5xx",boiler,173,auxheatmix,aux heater mixing valve,int8,%,false,sensor.boiler_aux_heater_mixing_valve,sensor.boiler_auxheatmix,6,0,1,235,1 +"Geo 5xx",boiler,173,tempdiffheat,temp diff TC3/TC0 heat,uint8 (>=2<=10),K,true,number.boiler_temp_diff_TC3/TC0_heat,number.boiler_tempdiffheat,6,0,1/10,236,1 +"Geo 5xx",boiler,173,tempdiffcool,temp diff TC3/TC0 cool,uint8 (>=2<=10),K,true,number.boiler_temp_diff_TC3/TC0_cool,number.boiler_tempdiffcool,6,0,1/10,237,1 +"Geo 5xx",boiler,173,vpcooling,valve/pump cooling,boolean (>=0<=0), ,true,switch.boiler_valve/pump_cooling,switch.boiler_vpcooling,6,0,1,238,1 +"Geo 5xx",boiler,173,heatcable,heating cable,boolean (>=0<=0), ,true,switch.boiler_heating_cable,switch.boiler_heatcable,6,0,1,239,1 +"Geo 5xx",boiler,173,vc0valve,VC0 valve,boolean (>=0<=0), ,true,switch.boiler_VC0_valve,switch.boiler_vc0valve,6,0,1,240,1 +"Geo 5xx",boiler,173,primepump,primary heatpump,boolean (>=0<=0), ,true,switch.boiler_primary_heatpump,switch.boiler_primepump,6,0,1,241,1 +"Geo 5xx",boiler,173,primepumpmod,primary heatpump modulation,uint8 (>=0<=0),%,true,number.boiler_primary_heatpump_modulation,number.boiler_primepumpmod,6,0,1,242,1 +"Geo 5xx",boiler,173,hp3way,3-way valve,boolean (>=0<=0), ,true,switch.boiler_3-way_valve,switch.boiler_hp3way,6,0,1,243,1 +"Geo 5xx",boiler,173,elheatstep1,el. heater step 1,boolean (>=0<=0), ,true,switch.boiler_el._heater_step_1,switch.boiler_elheatstep1,6,0,1,244,1 +"Geo 5xx",boiler,173,elheatstep2,el. heater step 2,boolean (>=0<=0), ,true,switch.boiler_el._heater_step_2,switch.boiler_elheatstep2,6,0,1,245,1 +"Geo 5xx",boiler,173,elheatstep3,el. heater step 3,boolean (>=0<=0), ,true,switch.boiler_el._heater_step_3,switch.boiler_elheatstep3,6,0,1,246,1 +"Geo 5xx",boiler,173,hpea0,condensate reservoir heating (EA0),boolean, ,false,binary_sensor.boiler_condensate_reservoir_heating_(EA0),binary_sensor.boiler_hpea0,6,0,1,247,1 +"Geo 5xx",boiler,173,hppumpmode,primary heatpump mode,enum [auto\|continuous] (>=0<=0), ,true,select.boiler_primary_heatpump_mode,select.boiler_hppumpmode,6,0,1,248,1 +"Geo 5xx",boiler,173,fan,fan,uint8 (>=20<=100),%,true,number.boiler_fan,number.boiler_fan,6,0,1,249,1 +"Geo 5xx",boiler,173,fanspd,fan speed,uint8,%,false,sensor.boiler_fan_speed,sensor.boiler_fanspd,6,0,1,250,1 +"Geo 5xx",boiler,173,shutdown,shutdown,cmd [off\|on] (>=0<=0), ,true,sensor.boiler_shutdown,sensor.boiler_shutdown,6,0,1,251,1 +"Geo 5xx",boiler,173,hpcurrpower,compressor current power,uint16,W,false,sensor.boiler_compressor_current_power,sensor.boiler_hpcurrpower,6,0,1,252,1 +"Geo 5xx",boiler,173,hppowerlimit,power limit,uint16 (>=0<=0),W,true,number.boiler_power_limit,number.boiler_hppowerlimit,6,0,1,253,1 "Geo 5xx",boiler,173,dhw.alternatingop,alternating operation,boolean (>=0<=0), ,true,switch.boiler_dhw_alternating_operation,switch.boiler_dhw_alternatingop,6,9,1,15,1 "Geo 5xx",boiler,173,dhw.altopprioheat,prioritise heating during dhw,uint8 (>=20<=120),minutes,true,number.boiler_dhw_prioritise_heating_during_dhw,number.boiler_dhw_altopprioheat,6,9,1,16,1 "Geo 5xx",boiler,173,dhw.altopprio,prioritise dhw during heating,uint8 (>=30<=120),minutes,true,number.boiler_dhw_prioritise_dhw_during_heating,number.boiler_dhw_altopprio,6,9,1,17,1 @@ -3067,28 +3090,28 @@ device name,device type,product id,shortname,fullname,type [options...] \| (min/ "Condens 5000i, Greenstar 8000/GC9800IW, GB192i*2",boiler,195,syspress,system pressure,uint8,bar,false,sensor.boiler_system_pressure,sensor.boiler_syspress,6,0,1/10,11,1 "Condens 5000i, Greenstar 8000/GC9800IW, GB192i*2",boiler,195,boiltemp,actual boiler temperature,uint16,C,false,sensor.boiler_actual_boiler_temperature,sensor.boiler_boiltemp,6,0,1/10,12,1 "Condens 5000i, Greenstar 8000/GC9800IW, GB192i*2",boiler,195,headertemp,low loss header,uint16,C,false,sensor.boiler_low_loss_header,sensor.boiler_headertemp,6,0,1/10,13,1 -"Condens 5000i, Greenstar 8000/GC9800IW, GB192i*2",boiler,195,exhausttemp,exhaust temperature,uint16,C,false,sensor.boiler_exhaust_temperature,sensor.boiler_exhausttemp,6,0,1/10,253,1 -"Condens 5000i, Greenstar 8000/GC9800IW, GB192i*2",boiler,195,burngas,gas,boolean, ,false,binary_sensor.boiler_gas,binary_sensor.boiler_burngas,6,0,1,254,1 -"Condens 5000i, Greenstar 8000/GC9800IW, GB192i*2",boiler,195,burngas2,gas stage 2,boolean, ,false,binary_sensor.boiler_gas_stage_2,binary_sensor.boiler_burngas2,6,0,1,255,1 -"Condens 5000i, Greenstar 8000/GC9800IW, GB192i*2",boiler,195,flamecurr,flame current,uint16,µA,false,sensor.boiler_flame_current,sensor.boiler_flamecurr,6,0,1/10,256,1 -"Condens 5000i, Greenstar 8000/GC9800IW, GB192i*2",boiler,195,fanwork,fan,boolean, ,false,binary_sensor.boiler_fan,binary_sensor.boiler_fanwork,6,0,1,257,1 -"Condens 5000i, Greenstar 8000/GC9800IW, GB192i*2",boiler,195,ignwork,ignition,boolean, ,false,binary_sensor.boiler_ignition,binary_sensor.boiler_ignwork,6,0,1,258,1 -"Condens 5000i, Greenstar 8000/GC9800IW, GB192i*2",boiler,195,oilpreheat,oil preheating,boolean, ,false,binary_sensor.boiler_oil_preheating,binary_sensor.boiler_oilpreheat,6,0,1,259,1 -"Condens 5000i, Greenstar 8000/GC9800IW, GB192i*2",boiler,195,burnminpower,burner min power,uint8 (>=0<=0),%,true,number.boiler_burner_min_power,number.boiler_burnminpower,6,0,1,260,1 -"Condens 5000i, Greenstar 8000/GC9800IW, GB192i*2",boiler,195,burnmaxpower,burner max power,uint8 (>=0<=254),%,true,number.boiler_burner_max_power,number.boiler_burnmaxpower,6,0,1,261,1 -"Condens 5000i, Greenstar 8000/GC9800IW, GB192i*2",boiler,195,burnminperiod,burner min period,uint8 (>=0<=120),minutes,true,number.boiler_burner_min_period,number.boiler_burnminperiod,6,0,1,262,1 -"Condens 5000i, Greenstar 8000/GC9800IW, GB192i*2",boiler,195,absburnpow,burner current power (absolute),uint8,%,false,sensor.boiler_burner_current_power_(absolute),sensor.boiler_absburnpow,6,0,1,263,1 -"Condens 5000i, Greenstar 8000/GC9800IW, GB192i*2",boiler,195,heatblock,Heatblock temperature,uint16,C,false,sensor.boiler_Heatblock_temperature,sensor.boiler_heatblock,6,0,1/10,264,1 -"Condens 5000i, Greenstar 8000/GC9800IW, GB192i*2",boiler,195,boilhyston,hysteresis on temperature,int8 (>=-20<=0),C,true,number.boiler_hysteresis_on_temperature,number.boiler_boilhyston,6,0,1,265,1 -"Condens 5000i, Greenstar 8000/GC9800IW, GB192i*2",boiler,195,boilhystoff,hysteresis off temperature,int8 (>=0<=20),C,true,number.boiler_hysteresis_off_temperature,number.boiler_boilhystoff,6,0,1,266,1 -"Condens 5000i, Greenstar 8000/GC9800IW, GB192i*2",boiler,195,boil2hyston,hysteresis stage 2 on temperature,int8 (>=-20<=0),C,true,number.boiler_hysteresis_stage_2_on_temperature,number.boiler_boil2hyston,6,0,1,267,1 -"Condens 5000i, Greenstar 8000/GC9800IW, GB192i*2",boiler,195,boil2hystoff,hysteresis stage 2 off temperature,int8 (>=0<=20),C,true,number.boiler_hysteresis_stage_2_off_temperature,number.boiler_boil2hystoff,6,0,1,268,1 -"Condens 5000i, Greenstar 8000/GC9800IW, GB192i*2",boiler,195,curveon,heatingcurve on,boolean (>=0<=0), ,true,switch.boiler_heatingcurve_on,switch.boiler_curveon,6,0,1,269,1 -"Condens 5000i, Greenstar 8000/GC9800IW, GB192i*2",boiler,195,curvebase,heatingcurve base,uint8 (>=20<=90),C,true,number.boiler_heatingcurve_base,number.boiler_curvebase,6,0,1,270,1 -"Condens 5000i, Greenstar 8000/GC9800IW, GB192i*2",boiler,195,curveend,heatingcurve end,uint8 (>=20<=90),C,true,number.boiler_heatingcurve_end,number.boiler_curveend,6,0,1,271,1 -"Condens 5000i, Greenstar 8000/GC9800IW, GB192i*2",boiler,195,summertemp,summer temperature,uint8 (>=0<=45),C,true,number.boiler_summer_temperature,number.boiler_summertemp,6,0,1,272,1 -"Condens 5000i, Greenstar 8000/GC9800IW, GB192i*2",boiler,195,nofrostmode,nofrost mode,boolean (>=0<=0), ,true,switch.boiler_nofrost_mode,switch.boiler_nofrostmode,6,0,1,273,1 -"Condens 5000i, Greenstar 8000/GC9800IW, GB192i*2",boiler,195,nofrosttemp,nofrost temperature,uint8 (>=0<=10),C,true,number.boiler_nofrost_temperature,number.boiler_nofrosttemp,6,0,1,274,1 +"Condens 5000i, Greenstar 8000/GC9800IW, GB192i*2",boiler,195,exhausttemp,exhaust temperature,uint16,C,false,sensor.boiler_exhaust_temperature,sensor.boiler_exhausttemp,6,0,1/10,254,1 +"Condens 5000i, Greenstar 8000/GC9800IW, GB192i*2",boiler,195,burngas,gas,boolean, ,false,binary_sensor.boiler_gas,binary_sensor.boiler_burngas,6,0,1,255,1 +"Condens 5000i, Greenstar 8000/GC9800IW, GB192i*2",boiler,195,burngas2,gas stage 2,boolean, ,false,binary_sensor.boiler_gas_stage_2,binary_sensor.boiler_burngas2,6,0,1,256,1 +"Condens 5000i, Greenstar 8000/GC9800IW, GB192i*2",boiler,195,flamecurr,flame current,uint16,µA,false,sensor.boiler_flame_current,sensor.boiler_flamecurr,6,0,1/10,257,1 +"Condens 5000i, Greenstar 8000/GC9800IW, GB192i*2",boiler,195,fanwork,fan,boolean, ,false,binary_sensor.boiler_fan,binary_sensor.boiler_fanwork,6,0,1,258,1 +"Condens 5000i, Greenstar 8000/GC9800IW, GB192i*2",boiler,195,ignwork,ignition,boolean, ,false,binary_sensor.boiler_ignition,binary_sensor.boiler_ignwork,6,0,1,259,1 +"Condens 5000i, Greenstar 8000/GC9800IW, GB192i*2",boiler,195,oilpreheat,oil preheating,boolean, ,false,binary_sensor.boiler_oil_preheating,binary_sensor.boiler_oilpreheat,6,0,1,260,1 +"Condens 5000i, Greenstar 8000/GC9800IW, GB192i*2",boiler,195,burnminpower,burner min power,uint8 (>=0<=0),%,true,number.boiler_burner_min_power,number.boiler_burnminpower,6,0,1,261,1 +"Condens 5000i, Greenstar 8000/GC9800IW, GB192i*2",boiler,195,burnmaxpower,burner max power,uint8 (>=0<=254),%,true,number.boiler_burner_max_power,number.boiler_burnmaxpower,6,0,1,262,1 +"Condens 5000i, Greenstar 8000/GC9800IW, GB192i*2",boiler,195,burnminperiod,burner min period,uint8 (>=0<=120),minutes,true,number.boiler_burner_min_period,number.boiler_burnminperiod,6,0,1,263,1 +"Condens 5000i, Greenstar 8000/GC9800IW, GB192i*2",boiler,195,absburnpow,burner current power (absolute),uint8,%,false,sensor.boiler_burner_current_power_(absolute),sensor.boiler_absburnpow,6,0,1,264,1 +"Condens 5000i, Greenstar 8000/GC9800IW, GB192i*2",boiler,195,heatblock,Heatblock temperature,uint16,C,false,sensor.boiler_Heatblock_temperature,sensor.boiler_heatblock,6,0,1/10,265,1 +"Condens 5000i, Greenstar 8000/GC9800IW, GB192i*2",boiler,195,boilhyston,hysteresis on temperature,int8 (>=-20<=0),C,true,number.boiler_hysteresis_on_temperature,number.boiler_boilhyston,6,0,1,266,1 +"Condens 5000i, Greenstar 8000/GC9800IW, GB192i*2",boiler,195,boilhystoff,hysteresis off temperature,int8 (>=0<=20),C,true,number.boiler_hysteresis_off_temperature,number.boiler_boilhystoff,6,0,1,267,1 +"Condens 5000i, Greenstar 8000/GC9800IW, GB192i*2",boiler,195,boil2hyston,hysteresis stage 2 on temperature,int8 (>=-20<=0),C,true,number.boiler_hysteresis_stage_2_on_temperature,number.boiler_boil2hyston,6,0,1,268,1 +"Condens 5000i, Greenstar 8000/GC9800IW, GB192i*2",boiler,195,boil2hystoff,hysteresis stage 2 off temperature,int8 (>=0<=20),C,true,number.boiler_hysteresis_stage_2_off_temperature,number.boiler_boil2hystoff,6,0,1,269,1 +"Condens 5000i, Greenstar 8000/GC9800IW, GB192i*2",boiler,195,curveon,heatingcurve on,boolean (>=0<=0), ,true,switch.boiler_heatingcurve_on,switch.boiler_curveon,6,0,1,270,1 +"Condens 5000i, Greenstar 8000/GC9800IW, GB192i*2",boiler,195,curvebase,heatingcurve base,uint8 (>=20<=90),C,true,number.boiler_heatingcurve_base,number.boiler_curvebase,6,0,1,271,1 +"Condens 5000i, Greenstar 8000/GC9800IW, GB192i*2",boiler,195,curveend,heatingcurve end,uint8 (>=20<=90),C,true,number.boiler_heatingcurve_end,number.boiler_curveend,6,0,1,272,1 +"Condens 5000i, Greenstar 8000/GC9800IW, GB192i*2",boiler,195,summertemp,summer temperature,uint8 (>=0<=45),C,true,number.boiler_summer_temperature,number.boiler_summertemp,6,0,1,273,1 +"Condens 5000i, Greenstar 8000/GC9800IW, GB192i*2",boiler,195,nofrostmode,nofrost mode,boolean (>=0<=0), ,true,switch.boiler_nofrost_mode,switch.boiler_nofrostmode,6,0,1,274,1 +"Condens 5000i, Greenstar 8000/GC9800IW, GB192i*2",boiler,195,nofrosttemp,nofrost temperature,uint8 (>=0<=10),C,true,number.boiler_nofrost_temperature,number.boiler_nofrosttemp,6,0,1,275,1 "Condens 5000i, Greenstar 8000/GC9800IW, GB192i*2",boiler,195,heatingactivated,heating activated,boolean (>=0<=0), ,true,switch.boiler_heating_activated,switch.boiler_heatingactivated,6,0,1,14,1 "Condens 5000i, Greenstar 8000/GC9800IW, GB192i*2",boiler,195,heatingtemp,heating temperature,uint8 (>=0<=90),C,true,number.boiler_heating_temperature,number.boiler_heatingtemp,6,0,1,15,1 "Condens 5000i, Greenstar 8000/GC9800IW, GB192i*2",boiler,195,heatingpump,heating pump,boolean, ,false,binary_sensor.boiler_heating_pump,binary_sensor.boiler_heatingpump,6,0,1,16,1 @@ -3115,18 +3138,19 @@ device name,device type,product id,shortname,fullname,type [options...] \| (min/ "Condens 5000i, Greenstar 8000/GC9800IW, GB192i*2",boiler,195,maintenancedate,next maintenance date,string (>=0<=0), ,true,sensor.boiler_next_maintenance_date,sensor.boiler_maintenancedate,6,0,1,72,6 "Condens 5000i, Greenstar 8000/GC9800IW, GB192i*2",boiler,195,emergencyops,emergency operation,boolean (>=0<=0), ,true,switch.boiler_emergency_operation,switch.boiler_emergencyops,6,0,1,78,1 "Condens 5000i, Greenstar 8000/GC9800IW, GB192i*2",boiler,195,emergencytemp,emergency temperature,uint8 (>=15<=70),C,true,number.boiler_emergency_temperature,number.boiler_emergencytemp,6,0,1,79,1 -"Condens 5000i, Greenstar 8000/GC9800IW, GB192i*2",boiler,195,pc0flow,Flow PC0,int16,l/h,false,sensor.boiler_Flow_PC0,sensor.boiler_pc0flow,6,0,1,80,1 -"Condens 5000i, Greenstar 8000/GC9800IW, GB192i*2",boiler,195,pc1flow,Flow PC1,int16,l/h,false,sensor.boiler_Flow_PC1,sensor.boiler_pc1flow,6,0,1,81,1 -"Condens 5000i, Greenstar 8000/GC9800IW, GB192i*2",boiler,195,pc1on,PC1,boolean, ,false,binary_sensor.boiler_PC1,binary_sensor.boiler_pc1on,6,0,1,82,1 -"Condens 5000i, Greenstar 8000/GC9800IW, GB192i*2",boiler,195,pc1rate,PC1 rate,uint8,%,false,sensor.boiler_PC1_rate,sensor.boiler_pc1rate,6,0,1,83,1 -"Condens 5000i, Greenstar 8000/GC9800IW, GB192i*2",boiler,195,pumpkickhour,pump kick hour,uint8 (>=0<=23),hours,true,number.boiler_pump_kick_hour,number.boiler_pumpkickhour,6,0,1,84,1 -"Condens 5000i, Greenstar 8000/GC9800IW, GB192i*2",boiler,195,pumpkickday,pump kick day,enum [mo\|tu\|we\|th\|fr\|sa\|su\|all] (>=0<=0), ,true,select.boiler_pump_kick_day,select.boiler_pumpkickday,6,0,1,85,1 -"Condens 5000i, Greenstar 8000/GC9800IW, GB192i*2",boiler,195,pumpkickdelay,pump kick delay,uint16 (>=0<=32767),minutes,true,number.boiler_pump_kick_delay,number.boiler_pumpkickdelay,6,0,1,86,1 -"Condens 5000i, Greenstar 8000/GC9800IW, GB192i*2",boiler,195,meterheat,meter heating,uint24,kWh,false,sensor.boiler_meter_heating,sensor.boiler_meterheat,6,0,1/10,100,2 +"Condens 5000i, Greenstar 8000/GC9800IW, GB192i*2",boiler,195,pc0lpm,Flow PC0,uint16,l/min,false,sensor.boiler_Flow_PC0,sensor.boiler_pc0lpm,6,0,1/10,80,1 +"Condens 5000i, Greenstar 8000/GC9800IW, GB192i*2",boiler,195,pc0flow,Flow PC0,uint16,l/h,false,sensor.boiler_Flow_PC0,sensor.boiler_pc0flow,6,0,1,81,1 +"Condens 5000i, Greenstar 8000/GC9800IW, GB192i*2",boiler,195,pc1flow,Flow PC1,uint16,l/h,false,sensor.boiler_Flow_PC1,sensor.boiler_pc1flow,6,0,1,82,1 +"Condens 5000i, Greenstar 8000/GC9800IW, GB192i*2",boiler,195,pc1on,PC1,boolean, ,false,binary_sensor.boiler_PC1,binary_sensor.boiler_pc1on,6,0,1,83,1 +"Condens 5000i, Greenstar 8000/GC9800IW, GB192i*2",boiler,195,pc1rate,PC1 rate,uint8,%,false,sensor.boiler_PC1_rate,sensor.boiler_pc1rate,6,0,1,84,1 +"Condens 5000i, Greenstar 8000/GC9800IW, GB192i*2",boiler,195,pumpkickhour,pump kick hour,uint8 (>=0<=23),hours,true,number.boiler_pump_kick_hour,number.boiler_pumpkickhour,6,0,1,85,1 +"Condens 5000i, Greenstar 8000/GC9800IW, GB192i*2",boiler,195,pumpkickday,pump kick day,enum [mo\|tu\|we\|th\|fr\|sa\|su\|all] (>=0<=0), ,true,select.boiler_pump_kick_day,select.boiler_pumpkickday,6,0,1,86,1 +"Condens 5000i, Greenstar 8000/GC9800IW, GB192i*2",boiler,195,pumpkickdelay,pump kick delay,uint16 (>=0<=32767),minutes,true,number.boiler_pump_kick_delay,number.boiler_pumpkickdelay,6,0,1,87,1 +"Condens 5000i, Greenstar 8000/GC9800IW, GB192i*2",boiler,195,meterheat,meter heating,uint24,kWh,false,sensor.boiler_meter_heating,sensor.boiler_meterheat,6,0,1/10,101,2 "Condens 5000i, Greenstar 8000/GC9800IW, GB192i*2",boiler,195,dhw.meter,meter,uint24,kWh,false,sensor.boiler_dhw_meter,sensor.boiler_dhw_meter,6,9,1/10,2,2 -"Condens 5000i, Greenstar 8000/GC9800IW, GB192i*2",boiler,195,gasmeterheat,gas meter heating,uint24,kWh,false,sensor.boiler_gas_meter_heating,sensor.boiler_gasmeterheat,6,0,1/10,275,2 +"Condens 5000i, Greenstar 8000/GC9800IW, GB192i*2",boiler,195,gasmeterheat,gas meter heating,uint24,kWh,false,sensor.boiler_gas_meter_heating,sensor.boiler_gasmeterheat,6,0,1/10,276,2 "Condens 5000i, Greenstar 8000/GC9800IW, GB192i*2",boiler,195,dhw.gasmeter,gas meter,uint24,kWh,false,sensor.boiler_dhw_gas_meter,sensor.boiler_dhw_gasmeter,6,9,1/10,71,2 -"Condens 5000i, Greenstar 8000/GC9800IW, GB192i*2",boiler,195,nrgheat2,energy heating 2,uint24,kWh,false,sensor.boiler_energy_heating_2,sensor.boiler_nrgheat2,6,0,1/10,277,2 +"Condens 5000i, Greenstar 8000/GC9800IW, GB192i*2",boiler,195,nrgheat2,energy heating 2,uint24,kWh,false,sensor.boiler_energy_heating_2,sensor.boiler_nrgheat2,6,0,1/10,278,2 "Condens 5000i, Greenstar 8000/GC9800IW, GB192i*2",boiler,195,dhw.nrg2,energy 2,uint24,kWh,false,sensor.boiler_dhw_energy_2,sensor.boiler_dhw_nrg2,6,9,1/10,73,2 "Condens 5000i, Greenstar 8000/GC9800IW, GB192i*2",boiler,195,dhw.tapactivated,turn on/off,boolean (>=0<=0), ,true,switch.boiler_dhw_turn_on/off,switch.boiler_dhw_tapactivated,6,9,1,28,1 "Condens 5000i, Greenstar 8000/GC9800IW, GB192i*2",boiler,195,dhw.settemp,set temperature,uint8,C,false,sensor.boiler_dhw_set_temperature,sensor.boiler_dhw_settemp,6,9,1,29,1 @@ -3169,9 +3193,9 @@ device name,device type,product id,shortname,fullname,type [options...] \| (min/ "Condens 5000i, Greenstar 8000/GC9800IW, GB192i*2",boiler,195,dhw.dhwprio,dhw priority,boolean (>=0<=0), ,true,switch.boiler_dhw_dhw_priority,switch.boiler_dhw_dhwprio,6,9,1,66,1 "Condens 5000i, Greenstar 8000/GC9800IW, GB192i*2",boiler,195,dhw.starts,starts,uint24, ,false,sensor.boiler_dhw_starts,sensor.boiler_dhw_starts,6,9,1,67,2 "Condens 5000i, Greenstar 8000/GC9800IW, GB192i*2",boiler,195,dhw.workm,active time,time,minutes,false,sensor.boiler_dhw_active_time,sensor.boiler_dhw_workm,6,9,1,69,2 -"Condens 5000i, Greenstar 8000/GC9800IW, GB192i*2",boiler,195,nompower,nominal Power,uint8 (>=0<=0),kW,true,number.boiler_nominal_Power,number.boiler_nompower,6,0,1,279,1 -"Condens 5000i, Greenstar 8000/GC9800IW, GB192i*2",boiler,195,nrgtotal,total energy,uint24,kWh,false,sensor.boiler_total_energy,sensor.boiler_nrgtotal,6,0,1/100,88,2 -"Condens 5000i, Greenstar 8000/GC9800IW, GB192i*2",boiler,195,nrgheat,energy heating,uint24 (>=0<=10000000),kWh,true,number.boiler_energy_heating,number.boiler_nrgheat,6,0,1/100,90,2 +"Condens 5000i, Greenstar 8000/GC9800IW, GB192i*2",boiler,195,nompower,nominal Power,uint8 (>=0<=0),kW,true,number.boiler_nominal_Power,number.boiler_nompower,6,0,1,280,1 +"Condens 5000i, Greenstar 8000/GC9800IW, GB192i*2",boiler,195,nrgtotal,total energy,uint24,kWh,false,sensor.boiler_total_energy,sensor.boiler_nrgtotal,6,0,1/100,89,2 +"Condens 5000i, Greenstar 8000/GC9800IW, GB192i*2",boiler,195,nrgheat,energy heating,uint24 (>=0<=10000000),kWh,true,number.boiler_energy_heating,number.boiler_nrgheat,6,0,1/100,91,2 "Condens 5000i, Greenstar 8000/GC9800IW, GB192i*2",boiler,195,dhw.nrg,energy,uint24 (>=0<=10000000),kWh,true,number.boiler_dhw_energy,number.boiler_dhw_nrg,6,9,1/100,0,2 "Logamax U122, Cerapur",boiler,203,reset,reset,cmd [-\|maintenance\|error\|history\|message\|hp error\|burner starts\|factory] (>=0<=0), ,true,sensor.boiler_reset,sensor.boiler_reset,6,0,1,0,1 "Logamax U122, Cerapur",boiler,203,chimneysweeper,chimney sweeper,cmd [off\|on] (>=0<=0), ,true,sensor.boiler_chimney_sweeper,sensor.boiler_chimneysweeper,6,0,1,1,1 @@ -3187,28 +3211,28 @@ device name,device type,product id,shortname,fullname,type [options...] \| (min/ "Logamax U122, Cerapur",boiler,203,syspress,system pressure,uint8,bar,false,sensor.boiler_system_pressure,sensor.boiler_syspress,6,0,1/10,11,1 "Logamax U122, Cerapur",boiler,203,boiltemp,actual boiler temperature,uint16,C,false,sensor.boiler_actual_boiler_temperature,sensor.boiler_boiltemp,6,0,1/10,12,1 "Logamax U122, Cerapur",boiler,203,headertemp,low loss header,uint16,C,false,sensor.boiler_low_loss_header,sensor.boiler_headertemp,6,0,1/10,13,1 -"Logamax U122, Cerapur",boiler,203,exhausttemp,exhaust temperature,uint16,C,false,sensor.boiler_exhaust_temperature,sensor.boiler_exhausttemp,6,0,1/10,253,1 -"Logamax U122, Cerapur",boiler,203,burngas,gas,boolean, ,false,binary_sensor.boiler_gas,binary_sensor.boiler_burngas,6,0,1,254,1 -"Logamax U122, Cerapur",boiler,203,burngas2,gas stage 2,boolean, ,false,binary_sensor.boiler_gas_stage_2,binary_sensor.boiler_burngas2,6,0,1,255,1 -"Logamax U122, Cerapur",boiler,203,flamecurr,flame current,uint16,µA,false,sensor.boiler_flame_current,sensor.boiler_flamecurr,6,0,1/10,256,1 -"Logamax U122, Cerapur",boiler,203,fanwork,fan,boolean, ,false,binary_sensor.boiler_fan,binary_sensor.boiler_fanwork,6,0,1,257,1 -"Logamax U122, Cerapur",boiler,203,ignwork,ignition,boolean, ,false,binary_sensor.boiler_ignition,binary_sensor.boiler_ignwork,6,0,1,258,1 -"Logamax U122, Cerapur",boiler,203,oilpreheat,oil preheating,boolean, ,false,binary_sensor.boiler_oil_preheating,binary_sensor.boiler_oilpreheat,6,0,1,259,1 -"Logamax U122, Cerapur",boiler,203,burnminpower,burner min power,uint8 (>=0<=0),%,true,number.boiler_burner_min_power,number.boiler_burnminpower,6,0,1,260,1 -"Logamax U122, Cerapur",boiler,203,burnmaxpower,burner max power,uint8 (>=0<=254),%,true,number.boiler_burner_max_power,number.boiler_burnmaxpower,6,0,1,261,1 -"Logamax U122, Cerapur",boiler,203,burnminperiod,burner min period,uint8 (>=0<=120),minutes,true,number.boiler_burner_min_period,number.boiler_burnminperiod,6,0,1,262,1 -"Logamax U122, Cerapur",boiler,203,absburnpow,burner current power (absolute),uint8,%,false,sensor.boiler_burner_current_power_(absolute),sensor.boiler_absburnpow,6,0,1,263,1 -"Logamax U122, Cerapur",boiler,203,heatblock,Heatblock temperature,uint16,C,false,sensor.boiler_Heatblock_temperature,sensor.boiler_heatblock,6,0,1/10,264,1 -"Logamax U122, Cerapur",boiler,203,boilhyston,hysteresis on temperature,int8 (>=-20<=0),C,true,number.boiler_hysteresis_on_temperature,number.boiler_boilhyston,6,0,1,265,1 -"Logamax U122, Cerapur",boiler,203,boilhystoff,hysteresis off temperature,int8 (>=0<=20),C,true,number.boiler_hysteresis_off_temperature,number.boiler_boilhystoff,6,0,1,266,1 -"Logamax U122, Cerapur",boiler,203,boil2hyston,hysteresis stage 2 on temperature,int8 (>=-20<=0),C,true,number.boiler_hysteresis_stage_2_on_temperature,number.boiler_boil2hyston,6,0,1,267,1 -"Logamax U122, Cerapur",boiler,203,boil2hystoff,hysteresis stage 2 off temperature,int8 (>=0<=20),C,true,number.boiler_hysteresis_stage_2_off_temperature,number.boiler_boil2hystoff,6,0,1,268,1 -"Logamax U122, Cerapur",boiler,203,curveon,heatingcurve on,boolean (>=0<=0), ,true,switch.boiler_heatingcurve_on,switch.boiler_curveon,6,0,1,269,1 -"Logamax U122, Cerapur",boiler,203,curvebase,heatingcurve base,uint8 (>=20<=90),C,true,number.boiler_heatingcurve_base,number.boiler_curvebase,6,0,1,270,1 -"Logamax U122, Cerapur",boiler,203,curveend,heatingcurve end,uint8 (>=20<=90),C,true,number.boiler_heatingcurve_end,number.boiler_curveend,6,0,1,271,1 -"Logamax U122, Cerapur",boiler,203,summertemp,summer temperature,uint8 (>=0<=45),C,true,number.boiler_summer_temperature,number.boiler_summertemp,6,0,1,272,1 -"Logamax U122, Cerapur",boiler,203,nofrostmode,nofrost mode,boolean (>=0<=0), ,true,switch.boiler_nofrost_mode,switch.boiler_nofrostmode,6,0,1,273,1 -"Logamax U122, Cerapur",boiler,203,nofrosttemp,nofrost temperature,uint8 (>=0<=10),C,true,number.boiler_nofrost_temperature,number.boiler_nofrosttemp,6,0,1,274,1 +"Logamax U122, Cerapur",boiler,203,exhausttemp,exhaust temperature,uint16,C,false,sensor.boiler_exhaust_temperature,sensor.boiler_exhausttemp,6,0,1/10,254,1 +"Logamax U122, Cerapur",boiler,203,burngas,gas,boolean, ,false,binary_sensor.boiler_gas,binary_sensor.boiler_burngas,6,0,1,255,1 +"Logamax U122, Cerapur",boiler,203,burngas2,gas stage 2,boolean, ,false,binary_sensor.boiler_gas_stage_2,binary_sensor.boiler_burngas2,6,0,1,256,1 +"Logamax U122, Cerapur",boiler,203,flamecurr,flame current,uint16,µA,false,sensor.boiler_flame_current,sensor.boiler_flamecurr,6,0,1/10,257,1 +"Logamax U122, Cerapur",boiler,203,fanwork,fan,boolean, ,false,binary_sensor.boiler_fan,binary_sensor.boiler_fanwork,6,0,1,258,1 +"Logamax U122, Cerapur",boiler,203,ignwork,ignition,boolean, ,false,binary_sensor.boiler_ignition,binary_sensor.boiler_ignwork,6,0,1,259,1 +"Logamax U122, Cerapur",boiler,203,oilpreheat,oil preheating,boolean, ,false,binary_sensor.boiler_oil_preheating,binary_sensor.boiler_oilpreheat,6,0,1,260,1 +"Logamax U122, Cerapur",boiler,203,burnminpower,burner min power,uint8 (>=0<=0),%,true,number.boiler_burner_min_power,number.boiler_burnminpower,6,0,1,261,1 +"Logamax U122, Cerapur",boiler,203,burnmaxpower,burner max power,uint8 (>=0<=254),%,true,number.boiler_burner_max_power,number.boiler_burnmaxpower,6,0,1,262,1 +"Logamax U122, Cerapur",boiler,203,burnminperiod,burner min period,uint8 (>=0<=120),minutes,true,number.boiler_burner_min_period,number.boiler_burnminperiod,6,0,1,263,1 +"Logamax U122, Cerapur",boiler,203,absburnpow,burner current power (absolute),uint8,%,false,sensor.boiler_burner_current_power_(absolute),sensor.boiler_absburnpow,6,0,1,264,1 +"Logamax U122, Cerapur",boiler,203,heatblock,Heatblock temperature,uint16,C,false,sensor.boiler_Heatblock_temperature,sensor.boiler_heatblock,6,0,1/10,265,1 +"Logamax U122, Cerapur",boiler,203,boilhyston,hysteresis on temperature,int8 (>=-20<=0),C,true,number.boiler_hysteresis_on_temperature,number.boiler_boilhyston,6,0,1,266,1 +"Logamax U122, Cerapur",boiler,203,boilhystoff,hysteresis off temperature,int8 (>=0<=20),C,true,number.boiler_hysteresis_off_temperature,number.boiler_boilhystoff,6,0,1,267,1 +"Logamax U122, Cerapur",boiler,203,boil2hyston,hysteresis stage 2 on temperature,int8 (>=-20<=0),C,true,number.boiler_hysteresis_stage_2_on_temperature,number.boiler_boil2hyston,6,0,1,268,1 +"Logamax U122, Cerapur",boiler,203,boil2hystoff,hysteresis stage 2 off temperature,int8 (>=0<=20),C,true,number.boiler_hysteresis_stage_2_off_temperature,number.boiler_boil2hystoff,6,0,1,269,1 +"Logamax U122, Cerapur",boiler,203,curveon,heatingcurve on,boolean (>=0<=0), ,true,switch.boiler_heatingcurve_on,switch.boiler_curveon,6,0,1,270,1 +"Logamax U122, Cerapur",boiler,203,curvebase,heatingcurve base,uint8 (>=20<=90),C,true,number.boiler_heatingcurve_base,number.boiler_curvebase,6,0,1,271,1 +"Logamax U122, Cerapur",boiler,203,curveend,heatingcurve end,uint8 (>=20<=90),C,true,number.boiler_heatingcurve_end,number.boiler_curveend,6,0,1,272,1 +"Logamax U122, Cerapur",boiler,203,summertemp,summer temperature,uint8 (>=0<=45),C,true,number.boiler_summer_temperature,number.boiler_summertemp,6,0,1,273,1 +"Logamax U122, Cerapur",boiler,203,nofrostmode,nofrost mode,boolean (>=0<=0), ,true,switch.boiler_nofrost_mode,switch.boiler_nofrostmode,6,0,1,274,1 +"Logamax U122, Cerapur",boiler,203,nofrosttemp,nofrost temperature,uint8 (>=0<=10),C,true,number.boiler_nofrost_temperature,number.boiler_nofrosttemp,6,0,1,275,1 "Logamax U122, Cerapur",boiler,203,heatingactivated,heating activated,boolean (>=0<=0), ,true,switch.boiler_heating_activated,switch.boiler_heatingactivated,6,0,1,14,1 "Logamax U122, Cerapur",boiler,203,heatingtemp,heating temperature,uint8 (>=0<=90),C,true,number.boiler_heating_temperature,number.boiler_heatingtemp,6,0,1,15,1 "Logamax U122, Cerapur",boiler,203,heatingpump,heating pump,boolean, ,false,binary_sensor.boiler_heating_pump,binary_sensor.boiler_heatingpump,6,0,1,16,1 @@ -3235,18 +3259,19 @@ device name,device type,product id,shortname,fullname,type [options...] \| (min/ "Logamax U122, Cerapur",boiler,203,maintenancedate,next maintenance date,string (>=0<=0), ,true,sensor.boiler_next_maintenance_date,sensor.boiler_maintenancedate,6,0,1,72,6 "Logamax U122, Cerapur",boiler,203,emergencyops,emergency operation,boolean (>=0<=0), ,true,switch.boiler_emergency_operation,switch.boiler_emergencyops,6,0,1,78,1 "Logamax U122, Cerapur",boiler,203,emergencytemp,emergency temperature,uint8 (>=15<=70),C,true,number.boiler_emergency_temperature,number.boiler_emergencytemp,6,0,1,79,1 -"Logamax U122, Cerapur",boiler,203,pc0flow,Flow PC0,int16,l/h,false,sensor.boiler_Flow_PC0,sensor.boiler_pc0flow,6,0,1,80,1 -"Logamax U122, Cerapur",boiler,203,pc1flow,Flow PC1,int16,l/h,false,sensor.boiler_Flow_PC1,sensor.boiler_pc1flow,6,0,1,81,1 -"Logamax U122, Cerapur",boiler,203,pc1on,PC1,boolean, ,false,binary_sensor.boiler_PC1,binary_sensor.boiler_pc1on,6,0,1,82,1 -"Logamax U122, Cerapur",boiler,203,pc1rate,PC1 rate,uint8,%,false,sensor.boiler_PC1_rate,sensor.boiler_pc1rate,6,0,1,83,1 -"Logamax U122, Cerapur",boiler,203,pumpkickhour,pump kick hour,uint8 (>=0<=23),hours,true,number.boiler_pump_kick_hour,number.boiler_pumpkickhour,6,0,1,84,1 -"Logamax U122, Cerapur",boiler,203,pumpkickday,pump kick day,enum [mo\|tu\|we\|th\|fr\|sa\|su\|all] (>=0<=0), ,true,select.boiler_pump_kick_day,select.boiler_pumpkickday,6,0,1,85,1 -"Logamax U122, Cerapur",boiler,203,pumpkickdelay,pump kick delay,uint16 (>=0<=32767),minutes,true,number.boiler_pump_kick_delay,number.boiler_pumpkickdelay,6,0,1,86,1 -"Logamax U122, Cerapur",boiler,203,meterheat,meter heating,uint24,kWh,false,sensor.boiler_meter_heating,sensor.boiler_meterheat,6,0,1/10,100,2 +"Logamax U122, Cerapur",boiler,203,pc0lpm,Flow PC0,uint16,l/min,false,sensor.boiler_Flow_PC0,sensor.boiler_pc0lpm,6,0,1/10,80,1 +"Logamax U122, Cerapur",boiler,203,pc0flow,Flow PC0,uint16,l/h,false,sensor.boiler_Flow_PC0,sensor.boiler_pc0flow,6,0,1,81,1 +"Logamax U122, Cerapur",boiler,203,pc1flow,Flow PC1,uint16,l/h,false,sensor.boiler_Flow_PC1,sensor.boiler_pc1flow,6,0,1,82,1 +"Logamax U122, Cerapur",boiler,203,pc1on,PC1,boolean, ,false,binary_sensor.boiler_PC1,binary_sensor.boiler_pc1on,6,0,1,83,1 +"Logamax U122, Cerapur",boiler,203,pc1rate,PC1 rate,uint8,%,false,sensor.boiler_PC1_rate,sensor.boiler_pc1rate,6,0,1,84,1 +"Logamax U122, Cerapur",boiler,203,pumpkickhour,pump kick hour,uint8 (>=0<=23),hours,true,number.boiler_pump_kick_hour,number.boiler_pumpkickhour,6,0,1,85,1 +"Logamax U122, Cerapur",boiler,203,pumpkickday,pump kick day,enum [mo\|tu\|we\|th\|fr\|sa\|su\|all] (>=0<=0), ,true,select.boiler_pump_kick_day,select.boiler_pumpkickday,6,0,1,86,1 +"Logamax U122, Cerapur",boiler,203,pumpkickdelay,pump kick delay,uint16 (>=0<=32767),minutes,true,number.boiler_pump_kick_delay,number.boiler_pumpkickdelay,6,0,1,87,1 +"Logamax U122, Cerapur",boiler,203,meterheat,meter heating,uint24,kWh,false,sensor.boiler_meter_heating,sensor.boiler_meterheat,6,0,1/10,101,2 "Logamax U122, Cerapur",boiler,203,dhw.meter,meter,uint24,kWh,false,sensor.boiler_dhw_meter,sensor.boiler_dhw_meter,6,9,1/10,2,2 -"Logamax U122, Cerapur",boiler,203,gasmeterheat,gas meter heating,uint24,kWh,false,sensor.boiler_gas_meter_heating,sensor.boiler_gasmeterheat,6,0,1/10,275,2 +"Logamax U122, Cerapur",boiler,203,gasmeterheat,gas meter heating,uint24,kWh,false,sensor.boiler_gas_meter_heating,sensor.boiler_gasmeterheat,6,0,1/10,276,2 "Logamax U122, Cerapur",boiler,203,dhw.gasmeter,gas meter,uint24,kWh,false,sensor.boiler_dhw_gas_meter,sensor.boiler_dhw_gasmeter,6,9,1/10,71,2 -"Logamax U122, Cerapur",boiler,203,nrgheat2,energy heating 2,uint24,kWh,false,sensor.boiler_energy_heating_2,sensor.boiler_nrgheat2,6,0,1/10,277,2 +"Logamax U122, Cerapur",boiler,203,nrgheat2,energy heating 2,uint24,kWh,false,sensor.boiler_energy_heating_2,sensor.boiler_nrgheat2,6,0,1/10,278,2 "Logamax U122, Cerapur",boiler,203,dhw.nrg2,energy 2,uint24,kWh,false,sensor.boiler_dhw_energy_2,sensor.boiler_dhw_nrg2,6,9,1/10,73,2 "Logamax U122, Cerapur",boiler,203,dhw.tapactivated,turn on/off,boolean (>=0<=0), ,true,switch.boiler_dhw_turn_on/off,switch.boiler_dhw_tapactivated,6,9,1,28,1 "Logamax U122, Cerapur",boiler,203,dhw.settemp,set temperature,uint8,C,false,sensor.boiler_dhw_set_temperature,sensor.boiler_dhw_settemp,6,9,1,29,1 @@ -3289,9 +3314,9 @@ device name,device type,product id,shortname,fullname,type [options...] \| (min/ "Logamax U122, Cerapur",boiler,203,dhw.dhwprio,dhw priority,boolean (>=0<=0), ,true,switch.boiler_dhw_dhw_priority,switch.boiler_dhw_dhwprio,6,9,1,66,1 "Logamax U122, Cerapur",boiler,203,dhw.starts,starts,uint24, ,false,sensor.boiler_dhw_starts,sensor.boiler_dhw_starts,6,9,1,67,2 "Logamax U122, Cerapur",boiler,203,dhw.workm,active time,time,minutes,false,sensor.boiler_dhw_active_time,sensor.boiler_dhw_workm,6,9,1,69,2 -"Logamax U122, Cerapur",boiler,203,nompower,nominal Power,uint8 (>=0<=0),kW,true,number.boiler_nominal_Power,number.boiler_nompower,6,0,1,279,1 -"Logamax U122, Cerapur",boiler,203,nrgtotal,total energy,uint24,kWh,false,sensor.boiler_total_energy,sensor.boiler_nrgtotal,6,0,1/100,88,2 -"Logamax U122, Cerapur",boiler,203,nrgheat,energy heating,uint24 (>=0<=10000000),kWh,true,number.boiler_energy_heating,number.boiler_nrgheat,6,0,1/100,90,2 +"Logamax U122, Cerapur",boiler,203,nompower,nominal Power,uint8 (>=0<=0),kW,true,number.boiler_nominal_Power,number.boiler_nompower,6,0,1,280,1 +"Logamax U122, Cerapur",boiler,203,nrgtotal,total energy,uint24,kWh,false,sensor.boiler_total_energy,sensor.boiler_nrgtotal,6,0,1/100,89,2 +"Logamax U122, Cerapur",boiler,203,nrgheat,energy heating,uint24 (>=0<=10000000),kWh,true,number.boiler_energy_heating,number.boiler_nrgheat,6,0,1/100,91,2 "Logamax U122, Cerapur",boiler,203,dhw.nrg,energy,uint24 (>=0<=10000000),kWh,true,number.boiler_dhw_energy,number.boiler_dhw_nrg,6,9,1/100,0,2 "Ecomline Excellent",boiler,206,reset,reset,cmd [-\|maintenance\|error\|history\|message\|hp error\|burner starts\|factory] (>=0<=0), ,true,sensor.boiler_reset,sensor.boiler_reset,6,0,1,0,1 "Ecomline Excellent",boiler,206,chimneysweeper,chimney sweeper,cmd [off\|on] (>=0<=0), ,true,sensor.boiler_chimney_sweeper,sensor.boiler_chimneysweeper,6,0,1,1,1 @@ -3307,28 +3332,28 @@ device name,device type,product id,shortname,fullname,type [options...] \| (min/ "Ecomline Excellent",boiler,206,syspress,system pressure,uint8,bar,false,sensor.boiler_system_pressure,sensor.boiler_syspress,6,0,1/10,11,1 "Ecomline Excellent",boiler,206,boiltemp,actual boiler temperature,uint16,C,false,sensor.boiler_actual_boiler_temperature,sensor.boiler_boiltemp,6,0,1/10,12,1 "Ecomline Excellent",boiler,206,headertemp,low loss header,uint16,C,false,sensor.boiler_low_loss_header,sensor.boiler_headertemp,6,0,1/10,13,1 -"Ecomline Excellent",boiler,206,exhausttemp,exhaust temperature,uint16,C,false,sensor.boiler_exhaust_temperature,sensor.boiler_exhausttemp,6,0,1/10,253,1 -"Ecomline Excellent",boiler,206,burngas,gas,boolean, ,false,binary_sensor.boiler_gas,binary_sensor.boiler_burngas,6,0,1,254,1 -"Ecomline Excellent",boiler,206,burngas2,gas stage 2,boolean, ,false,binary_sensor.boiler_gas_stage_2,binary_sensor.boiler_burngas2,6,0,1,255,1 -"Ecomline Excellent",boiler,206,flamecurr,flame current,uint16,µA,false,sensor.boiler_flame_current,sensor.boiler_flamecurr,6,0,1/10,256,1 -"Ecomline Excellent",boiler,206,fanwork,fan,boolean, ,false,binary_sensor.boiler_fan,binary_sensor.boiler_fanwork,6,0,1,257,1 -"Ecomline Excellent",boiler,206,ignwork,ignition,boolean, ,false,binary_sensor.boiler_ignition,binary_sensor.boiler_ignwork,6,0,1,258,1 -"Ecomline Excellent",boiler,206,oilpreheat,oil preheating,boolean, ,false,binary_sensor.boiler_oil_preheating,binary_sensor.boiler_oilpreheat,6,0,1,259,1 -"Ecomline Excellent",boiler,206,burnminpower,burner min power,uint8 (>=0<=0),%,true,number.boiler_burner_min_power,number.boiler_burnminpower,6,0,1,260,1 -"Ecomline Excellent",boiler,206,burnmaxpower,burner max power,uint8 (>=0<=254),%,true,number.boiler_burner_max_power,number.boiler_burnmaxpower,6,0,1,261,1 -"Ecomline Excellent",boiler,206,burnminperiod,burner min period,uint8 (>=0<=120),minutes,true,number.boiler_burner_min_period,number.boiler_burnminperiod,6,0,1,262,1 -"Ecomline Excellent",boiler,206,absburnpow,burner current power (absolute),uint8,%,false,sensor.boiler_burner_current_power_(absolute),sensor.boiler_absburnpow,6,0,1,263,1 -"Ecomline Excellent",boiler,206,heatblock,Heatblock temperature,uint16,C,false,sensor.boiler_Heatblock_temperature,sensor.boiler_heatblock,6,0,1/10,264,1 -"Ecomline Excellent",boiler,206,boilhyston,hysteresis on temperature,int8 (>=-20<=0),C,true,number.boiler_hysteresis_on_temperature,number.boiler_boilhyston,6,0,1,265,1 -"Ecomline Excellent",boiler,206,boilhystoff,hysteresis off temperature,int8 (>=0<=20),C,true,number.boiler_hysteresis_off_temperature,number.boiler_boilhystoff,6,0,1,266,1 -"Ecomline Excellent",boiler,206,boil2hyston,hysteresis stage 2 on temperature,int8 (>=-20<=0),C,true,number.boiler_hysteresis_stage_2_on_temperature,number.boiler_boil2hyston,6,0,1,267,1 -"Ecomline Excellent",boiler,206,boil2hystoff,hysteresis stage 2 off temperature,int8 (>=0<=20),C,true,number.boiler_hysteresis_stage_2_off_temperature,number.boiler_boil2hystoff,6,0,1,268,1 -"Ecomline Excellent",boiler,206,curveon,heatingcurve on,boolean (>=0<=0), ,true,switch.boiler_heatingcurve_on,switch.boiler_curveon,6,0,1,269,1 -"Ecomline Excellent",boiler,206,curvebase,heatingcurve base,uint8 (>=20<=90),C,true,number.boiler_heatingcurve_base,number.boiler_curvebase,6,0,1,270,1 -"Ecomline Excellent",boiler,206,curveend,heatingcurve end,uint8 (>=20<=90),C,true,number.boiler_heatingcurve_end,number.boiler_curveend,6,0,1,271,1 -"Ecomline Excellent",boiler,206,summertemp,summer temperature,uint8 (>=0<=45),C,true,number.boiler_summer_temperature,number.boiler_summertemp,6,0,1,272,1 -"Ecomline Excellent",boiler,206,nofrostmode,nofrost mode,boolean (>=0<=0), ,true,switch.boiler_nofrost_mode,switch.boiler_nofrostmode,6,0,1,273,1 -"Ecomline Excellent",boiler,206,nofrosttemp,nofrost temperature,uint8 (>=0<=10),C,true,number.boiler_nofrost_temperature,number.boiler_nofrosttemp,6,0,1,274,1 +"Ecomline Excellent",boiler,206,exhausttemp,exhaust temperature,uint16,C,false,sensor.boiler_exhaust_temperature,sensor.boiler_exhausttemp,6,0,1/10,254,1 +"Ecomline Excellent",boiler,206,burngas,gas,boolean, ,false,binary_sensor.boiler_gas,binary_sensor.boiler_burngas,6,0,1,255,1 +"Ecomline Excellent",boiler,206,burngas2,gas stage 2,boolean, ,false,binary_sensor.boiler_gas_stage_2,binary_sensor.boiler_burngas2,6,0,1,256,1 +"Ecomline Excellent",boiler,206,flamecurr,flame current,uint16,µA,false,sensor.boiler_flame_current,sensor.boiler_flamecurr,6,0,1/10,257,1 +"Ecomline Excellent",boiler,206,fanwork,fan,boolean, ,false,binary_sensor.boiler_fan,binary_sensor.boiler_fanwork,6,0,1,258,1 +"Ecomline Excellent",boiler,206,ignwork,ignition,boolean, ,false,binary_sensor.boiler_ignition,binary_sensor.boiler_ignwork,6,0,1,259,1 +"Ecomline Excellent",boiler,206,oilpreheat,oil preheating,boolean, ,false,binary_sensor.boiler_oil_preheating,binary_sensor.boiler_oilpreheat,6,0,1,260,1 +"Ecomline Excellent",boiler,206,burnminpower,burner min power,uint8 (>=0<=0),%,true,number.boiler_burner_min_power,number.boiler_burnminpower,6,0,1,261,1 +"Ecomline Excellent",boiler,206,burnmaxpower,burner max power,uint8 (>=0<=254),%,true,number.boiler_burner_max_power,number.boiler_burnmaxpower,6,0,1,262,1 +"Ecomline Excellent",boiler,206,burnminperiod,burner min period,uint8 (>=0<=120),minutes,true,number.boiler_burner_min_period,number.boiler_burnminperiod,6,0,1,263,1 +"Ecomline Excellent",boiler,206,absburnpow,burner current power (absolute),uint8,%,false,sensor.boiler_burner_current_power_(absolute),sensor.boiler_absburnpow,6,0,1,264,1 +"Ecomline Excellent",boiler,206,heatblock,Heatblock temperature,uint16,C,false,sensor.boiler_Heatblock_temperature,sensor.boiler_heatblock,6,0,1/10,265,1 +"Ecomline Excellent",boiler,206,boilhyston,hysteresis on temperature,int8 (>=-20<=0),C,true,number.boiler_hysteresis_on_temperature,number.boiler_boilhyston,6,0,1,266,1 +"Ecomline Excellent",boiler,206,boilhystoff,hysteresis off temperature,int8 (>=0<=20),C,true,number.boiler_hysteresis_off_temperature,number.boiler_boilhystoff,6,0,1,267,1 +"Ecomline Excellent",boiler,206,boil2hyston,hysteresis stage 2 on temperature,int8 (>=-20<=0),C,true,number.boiler_hysteresis_stage_2_on_temperature,number.boiler_boil2hyston,6,0,1,268,1 +"Ecomline Excellent",boiler,206,boil2hystoff,hysteresis stage 2 off temperature,int8 (>=0<=20),C,true,number.boiler_hysteresis_stage_2_off_temperature,number.boiler_boil2hystoff,6,0,1,269,1 +"Ecomline Excellent",boiler,206,curveon,heatingcurve on,boolean (>=0<=0), ,true,switch.boiler_heatingcurve_on,switch.boiler_curveon,6,0,1,270,1 +"Ecomline Excellent",boiler,206,curvebase,heatingcurve base,uint8 (>=20<=90),C,true,number.boiler_heatingcurve_base,number.boiler_curvebase,6,0,1,271,1 +"Ecomline Excellent",boiler,206,curveend,heatingcurve end,uint8 (>=20<=90),C,true,number.boiler_heatingcurve_end,number.boiler_curveend,6,0,1,272,1 +"Ecomline Excellent",boiler,206,summertemp,summer temperature,uint8 (>=0<=45),C,true,number.boiler_summer_temperature,number.boiler_summertemp,6,0,1,273,1 +"Ecomline Excellent",boiler,206,nofrostmode,nofrost mode,boolean (>=0<=0), ,true,switch.boiler_nofrost_mode,switch.boiler_nofrostmode,6,0,1,274,1 +"Ecomline Excellent",boiler,206,nofrosttemp,nofrost temperature,uint8 (>=0<=10),C,true,number.boiler_nofrost_temperature,number.boiler_nofrosttemp,6,0,1,275,1 "Ecomline Excellent",boiler,206,heatingactivated,heating activated,boolean (>=0<=0), ,true,switch.boiler_heating_activated,switch.boiler_heatingactivated,6,0,1,14,1 "Ecomline Excellent",boiler,206,heatingtemp,heating temperature,uint8 (>=0<=90),C,true,number.boiler_heating_temperature,number.boiler_heatingtemp,6,0,1,15,1 "Ecomline Excellent",boiler,206,heatingpump,heating pump,boolean, ,false,binary_sensor.boiler_heating_pump,binary_sensor.boiler_heatingpump,6,0,1,16,1 @@ -3355,18 +3380,19 @@ device name,device type,product id,shortname,fullname,type [options...] \| (min/ "Ecomline Excellent",boiler,206,maintenancedate,next maintenance date,string (>=0<=0), ,true,sensor.boiler_next_maintenance_date,sensor.boiler_maintenancedate,6,0,1,72,6 "Ecomline Excellent",boiler,206,emergencyops,emergency operation,boolean (>=0<=0), ,true,switch.boiler_emergency_operation,switch.boiler_emergencyops,6,0,1,78,1 "Ecomline Excellent",boiler,206,emergencytemp,emergency temperature,uint8 (>=15<=70),C,true,number.boiler_emergency_temperature,number.boiler_emergencytemp,6,0,1,79,1 -"Ecomline Excellent",boiler,206,pc0flow,Flow PC0,int16,l/h,false,sensor.boiler_Flow_PC0,sensor.boiler_pc0flow,6,0,1,80,1 -"Ecomline Excellent",boiler,206,pc1flow,Flow PC1,int16,l/h,false,sensor.boiler_Flow_PC1,sensor.boiler_pc1flow,6,0,1,81,1 -"Ecomline Excellent",boiler,206,pc1on,PC1,boolean, ,false,binary_sensor.boiler_PC1,binary_sensor.boiler_pc1on,6,0,1,82,1 -"Ecomline Excellent",boiler,206,pc1rate,PC1 rate,uint8,%,false,sensor.boiler_PC1_rate,sensor.boiler_pc1rate,6,0,1,83,1 -"Ecomline Excellent",boiler,206,pumpkickhour,pump kick hour,uint8 (>=0<=23),hours,true,number.boiler_pump_kick_hour,number.boiler_pumpkickhour,6,0,1,84,1 -"Ecomline Excellent",boiler,206,pumpkickday,pump kick day,enum [mo\|tu\|we\|th\|fr\|sa\|su\|all] (>=0<=0), ,true,select.boiler_pump_kick_day,select.boiler_pumpkickday,6,0,1,85,1 -"Ecomline Excellent",boiler,206,pumpkickdelay,pump kick delay,uint16 (>=0<=32767),minutes,true,number.boiler_pump_kick_delay,number.boiler_pumpkickdelay,6,0,1,86,1 -"Ecomline Excellent",boiler,206,meterheat,meter heating,uint24,kWh,false,sensor.boiler_meter_heating,sensor.boiler_meterheat,6,0,1/10,100,2 +"Ecomline Excellent",boiler,206,pc0lpm,Flow PC0,uint16,l/min,false,sensor.boiler_Flow_PC0,sensor.boiler_pc0lpm,6,0,1/10,80,1 +"Ecomline Excellent",boiler,206,pc0flow,Flow PC0,uint16,l/h,false,sensor.boiler_Flow_PC0,sensor.boiler_pc0flow,6,0,1,81,1 +"Ecomline Excellent",boiler,206,pc1flow,Flow PC1,uint16,l/h,false,sensor.boiler_Flow_PC1,sensor.boiler_pc1flow,6,0,1,82,1 +"Ecomline Excellent",boiler,206,pc1on,PC1,boolean, ,false,binary_sensor.boiler_PC1,binary_sensor.boiler_pc1on,6,0,1,83,1 +"Ecomline Excellent",boiler,206,pc1rate,PC1 rate,uint8,%,false,sensor.boiler_PC1_rate,sensor.boiler_pc1rate,6,0,1,84,1 +"Ecomline Excellent",boiler,206,pumpkickhour,pump kick hour,uint8 (>=0<=23),hours,true,number.boiler_pump_kick_hour,number.boiler_pumpkickhour,6,0,1,85,1 +"Ecomline Excellent",boiler,206,pumpkickday,pump kick day,enum [mo\|tu\|we\|th\|fr\|sa\|su\|all] (>=0<=0), ,true,select.boiler_pump_kick_day,select.boiler_pumpkickday,6,0,1,86,1 +"Ecomline Excellent",boiler,206,pumpkickdelay,pump kick delay,uint16 (>=0<=32767),minutes,true,number.boiler_pump_kick_delay,number.boiler_pumpkickdelay,6,0,1,87,1 +"Ecomline Excellent",boiler,206,meterheat,meter heating,uint24,kWh,false,sensor.boiler_meter_heating,sensor.boiler_meterheat,6,0,1/10,101,2 "Ecomline Excellent",boiler,206,dhw.meter,meter,uint24,kWh,false,sensor.boiler_dhw_meter,sensor.boiler_dhw_meter,6,9,1/10,2,2 -"Ecomline Excellent",boiler,206,gasmeterheat,gas meter heating,uint24,kWh,false,sensor.boiler_gas_meter_heating,sensor.boiler_gasmeterheat,6,0,1/10,275,2 +"Ecomline Excellent",boiler,206,gasmeterheat,gas meter heating,uint24,kWh,false,sensor.boiler_gas_meter_heating,sensor.boiler_gasmeterheat,6,0,1/10,276,2 "Ecomline Excellent",boiler,206,dhw.gasmeter,gas meter,uint24,kWh,false,sensor.boiler_dhw_gas_meter,sensor.boiler_dhw_gasmeter,6,9,1/10,71,2 -"Ecomline Excellent",boiler,206,nrgheat2,energy heating 2,uint24,kWh,false,sensor.boiler_energy_heating_2,sensor.boiler_nrgheat2,6,0,1/10,277,2 +"Ecomline Excellent",boiler,206,nrgheat2,energy heating 2,uint24,kWh,false,sensor.boiler_energy_heating_2,sensor.boiler_nrgheat2,6,0,1/10,278,2 "Ecomline Excellent",boiler,206,dhw.nrg2,energy 2,uint24,kWh,false,sensor.boiler_dhw_energy_2,sensor.boiler_dhw_nrg2,6,9,1/10,73,2 "Ecomline Excellent",boiler,206,dhw.tapactivated,turn on/off,boolean (>=0<=0), ,true,switch.boiler_dhw_turn_on/off,switch.boiler_dhw_tapactivated,6,9,1,28,1 "Ecomline Excellent",boiler,206,dhw.settemp,set temperature,uint8,C,false,sensor.boiler_dhw_set_temperature,sensor.boiler_dhw_settemp,6,9,1,29,1 @@ -3409,9 +3435,9 @@ device name,device type,product id,shortname,fullname,type [options...] \| (min/ "Ecomline Excellent",boiler,206,dhw.dhwprio,dhw priority,boolean (>=0<=0), ,true,switch.boiler_dhw_dhw_priority,switch.boiler_dhw_dhwprio,6,9,1,66,1 "Ecomline Excellent",boiler,206,dhw.starts,starts,uint24, ,false,sensor.boiler_dhw_starts,sensor.boiler_dhw_starts,6,9,1,67,2 "Ecomline Excellent",boiler,206,dhw.workm,active time,time,minutes,false,sensor.boiler_dhw_active_time,sensor.boiler_dhw_workm,6,9,1,69,2 -"Ecomline Excellent",boiler,206,nompower,nominal Power,uint8 (>=0<=0),kW,true,number.boiler_nominal_Power,number.boiler_nompower,6,0,1,279,1 -"Ecomline Excellent",boiler,206,nrgtotal,total energy,uint24,kWh,false,sensor.boiler_total_energy,sensor.boiler_nrgtotal,6,0,1/100,88,2 -"Ecomline Excellent",boiler,206,nrgheat,energy heating,uint24 (>=0<=10000000),kWh,true,number.boiler_energy_heating,number.boiler_nrgheat,6,0,1/100,90,2 +"Ecomline Excellent",boiler,206,nompower,nominal Power,uint8 (>=0<=0),kW,true,number.boiler_nominal_Power,number.boiler_nompower,6,0,1,280,1 +"Ecomline Excellent",boiler,206,nrgtotal,total energy,uint24,kWh,false,sensor.boiler_total_energy,sensor.boiler_nrgtotal,6,0,1/100,89,2 +"Ecomline Excellent",boiler,206,nrgheat,energy heating,uint24 (>=0<=10000000),kWh,true,number.boiler_energy_heating,number.boiler_nrgheat,6,0,1/100,91,2 "Ecomline Excellent",boiler,206,dhw.nrg,energy,uint24 (>=0<=10000000),kWh,true,number.boiler_dhw_energy,number.boiler_dhw_nrg,6,9,1/100,0,2 "Logamax Plus, GB192, Condens GC9000, Greenstar ErP",boiler,208,reset,reset,cmd [-\|maintenance\|error\|history\|message\|hp error\|burner starts\|factory] (>=0<=0), ,true,sensor.boiler_reset,sensor.boiler_reset,6,0,1,0,1 "Logamax Plus, GB192, Condens GC9000, Greenstar ErP",boiler,208,chimneysweeper,chimney sweeper,cmd [off\|on] (>=0<=0), ,true,sensor.boiler_chimney_sweeper,sensor.boiler_chimneysweeper,6,0,1,1,1 @@ -3427,28 +3453,28 @@ device name,device type,product id,shortname,fullname,type [options...] \| (min/ "Logamax Plus, GB192, Condens GC9000, Greenstar ErP",boiler,208,syspress,system pressure,uint8,bar,false,sensor.boiler_system_pressure,sensor.boiler_syspress,6,0,1/10,11,1 "Logamax Plus, GB192, Condens GC9000, Greenstar ErP",boiler,208,boiltemp,actual boiler temperature,uint16,C,false,sensor.boiler_actual_boiler_temperature,sensor.boiler_boiltemp,6,0,1/10,12,1 "Logamax Plus, GB192, Condens GC9000, Greenstar ErP",boiler,208,headertemp,low loss header,uint16,C,false,sensor.boiler_low_loss_header,sensor.boiler_headertemp,6,0,1/10,13,1 -"Logamax Plus, GB192, Condens GC9000, Greenstar ErP",boiler,208,exhausttemp,exhaust temperature,uint16,C,false,sensor.boiler_exhaust_temperature,sensor.boiler_exhausttemp,6,0,1/10,253,1 -"Logamax Plus, GB192, Condens GC9000, Greenstar ErP",boiler,208,burngas,gas,boolean, ,false,binary_sensor.boiler_gas,binary_sensor.boiler_burngas,6,0,1,254,1 -"Logamax Plus, GB192, Condens GC9000, Greenstar ErP",boiler,208,burngas2,gas stage 2,boolean, ,false,binary_sensor.boiler_gas_stage_2,binary_sensor.boiler_burngas2,6,0,1,255,1 -"Logamax Plus, GB192, Condens GC9000, Greenstar ErP",boiler,208,flamecurr,flame current,uint16,µA,false,sensor.boiler_flame_current,sensor.boiler_flamecurr,6,0,1/10,256,1 -"Logamax Plus, GB192, Condens GC9000, Greenstar ErP",boiler,208,fanwork,fan,boolean, ,false,binary_sensor.boiler_fan,binary_sensor.boiler_fanwork,6,0,1,257,1 -"Logamax Plus, GB192, Condens GC9000, Greenstar ErP",boiler,208,ignwork,ignition,boolean, ,false,binary_sensor.boiler_ignition,binary_sensor.boiler_ignwork,6,0,1,258,1 -"Logamax Plus, GB192, Condens GC9000, Greenstar ErP",boiler,208,oilpreheat,oil preheating,boolean, ,false,binary_sensor.boiler_oil_preheating,binary_sensor.boiler_oilpreheat,6,0,1,259,1 -"Logamax Plus, GB192, Condens GC9000, Greenstar ErP",boiler,208,burnminpower,burner min power,uint8 (>=0<=0),%,true,number.boiler_burner_min_power,number.boiler_burnminpower,6,0,1,260,1 -"Logamax Plus, GB192, Condens GC9000, Greenstar ErP",boiler,208,burnmaxpower,burner max power,uint8 (>=0<=254),%,true,number.boiler_burner_max_power,number.boiler_burnmaxpower,6,0,1,261,1 -"Logamax Plus, GB192, Condens GC9000, Greenstar ErP",boiler,208,burnminperiod,burner min period,uint8 (>=0<=120),minutes,true,number.boiler_burner_min_period,number.boiler_burnminperiod,6,0,1,262,1 -"Logamax Plus, GB192, Condens GC9000, Greenstar ErP",boiler,208,absburnpow,burner current power (absolute),uint8,%,false,sensor.boiler_burner_current_power_(absolute),sensor.boiler_absburnpow,6,0,1,263,1 -"Logamax Plus, GB192, Condens GC9000, Greenstar ErP",boiler,208,heatblock,Heatblock temperature,uint16,C,false,sensor.boiler_Heatblock_temperature,sensor.boiler_heatblock,6,0,1/10,264,1 -"Logamax Plus, GB192, Condens GC9000, Greenstar ErP",boiler,208,boilhyston,hysteresis on temperature,int8 (>=-20<=0),C,true,number.boiler_hysteresis_on_temperature,number.boiler_boilhyston,6,0,1,265,1 -"Logamax Plus, GB192, Condens GC9000, Greenstar ErP",boiler,208,boilhystoff,hysteresis off temperature,int8 (>=0<=20),C,true,number.boiler_hysteresis_off_temperature,number.boiler_boilhystoff,6,0,1,266,1 -"Logamax Plus, GB192, Condens GC9000, Greenstar ErP",boiler,208,boil2hyston,hysteresis stage 2 on temperature,int8 (>=-20<=0),C,true,number.boiler_hysteresis_stage_2_on_temperature,number.boiler_boil2hyston,6,0,1,267,1 -"Logamax Plus, GB192, Condens GC9000, Greenstar ErP",boiler,208,boil2hystoff,hysteresis stage 2 off temperature,int8 (>=0<=20),C,true,number.boiler_hysteresis_stage_2_off_temperature,number.boiler_boil2hystoff,6,0,1,268,1 -"Logamax Plus, GB192, Condens GC9000, Greenstar ErP",boiler,208,curveon,heatingcurve on,boolean (>=0<=0), ,true,switch.boiler_heatingcurve_on,switch.boiler_curveon,6,0,1,269,1 -"Logamax Plus, GB192, Condens GC9000, Greenstar ErP",boiler,208,curvebase,heatingcurve base,uint8 (>=20<=90),C,true,number.boiler_heatingcurve_base,number.boiler_curvebase,6,0,1,270,1 -"Logamax Plus, GB192, Condens GC9000, Greenstar ErP",boiler,208,curveend,heatingcurve end,uint8 (>=20<=90),C,true,number.boiler_heatingcurve_end,number.boiler_curveend,6,0,1,271,1 -"Logamax Plus, GB192, Condens GC9000, Greenstar ErP",boiler,208,summertemp,summer temperature,uint8 (>=0<=45),C,true,number.boiler_summer_temperature,number.boiler_summertemp,6,0,1,272,1 -"Logamax Plus, GB192, Condens GC9000, Greenstar ErP",boiler,208,nofrostmode,nofrost mode,boolean (>=0<=0), ,true,switch.boiler_nofrost_mode,switch.boiler_nofrostmode,6,0,1,273,1 -"Logamax Plus, GB192, Condens GC9000, Greenstar ErP",boiler,208,nofrosttemp,nofrost temperature,uint8 (>=0<=10),C,true,number.boiler_nofrost_temperature,number.boiler_nofrosttemp,6,0,1,274,1 +"Logamax Plus, GB192, Condens GC9000, Greenstar ErP",boiler,208,exhausttemp,exhaust temperature,uint16,C,false,sensor.boiler_exhaust_temperature,sensor.boiler_exhausttemp,6,0,1/10,254,1 +"Logamax Plus, GB192, Condens GC9000, Greenstar ErP",boiler,208,burngas,gas,boolean, ,false,binary_sensor.boiler_gas,binary_sensor.boiler_burngas,6,0,1,255,1 +"Logamax Plus, GB192, Condens GC9000, Greenstar ErP",boiler,208,burngas2,gas stage 2,boolean, ,false,binary_sensor.boiler_gas_stage_2,binary_sensor.boiler_burngas2,6,0,1,256,1 +"Logamax Plus, GB192, Condens GC9000, Greenstar ErP",boiler,208,flamecurr,flame current,uint16,µA,false,sensor.boiler_flame_current,sensor.boiler_flamecurr,6,0,1/10,257,1 +"Logamax Plus, GB192, Condens GC9000, Greenstar ErP",boiler,208,fanwork,fan,boolean, ,false,binary_sensor.boiler_fan,binary_sensor.boiler_fanwork,6,0,1,258,1 +"Logamax Plus, GB192, Condens GC9000, Greenstar ErP",boiler,208,ignwork,ignition,boolean, ,false,binary_sensor.boiler_ignition,binary_sensor.boiler_ignwork,6,0,1,259,1 +"Logamax Plus, GB192, Condens GC9000, Greenstar ErP",boiler,208,oilpreheat,oil preheating,boolean, ,false,binary_sensor.boiler_oil_preheating,binary_sensor.boiler_oilpreheat,6,0,1,260,1 +"Logamax Plus, GB192, Condens GC9000, Greenstar ErP",boiler,208,burnminpower,burner min power,uint8 (>=0<=0),%,true,number.boiler_burner_min_power,number.boiler_burnminpower,6,0,1,261,1 +"Logamax Plus, GB192, Condens GC9000, Greenstar ErP",boiler,208,burnmaxpower,burner max power,uint8 (>=0<=254),%,true,number.boiler_burner_max_power,number.boiler_burnmaxpower,6,0,1,262,1 +"Logamax Plus, GB192, Condens GC9000, Greenstar ErP",boiler,208,burnminperiod,burner min period,uint8 (>=0<=120),minutes,true,number.boiler_burner_min_period,number.boiler_burnminperiod,6,0,1,263,1 +"Logamax Plus, GB192, Condens GC9000, Greenstar ErP",boiler,208,absburnpow,burner current power (absolute),uint8,%,false,sensor.boiler_burner_current_power_(absolute),sensor.boiler_absburnpow,6,0,1,264,1 +"Logamax Plus, GB192, Condens GC9000, Greenstar ErP",boiler,208,heatblock,Heatblock temperature,uint16,C,false,sensor.boiler_Heatblock_temperature,sensor.boiler_heatblock,6,0,1/10,265,1 +"Logamax Plus, GB192, Condens GC9000, Greenstar ErP",boiler,208,boilhyston,hysteresis on temperature,int8 (>=-20<=0),C,true,number.boiler_hysteresis_on_temperature,number.boiler_boilhyston,6,0,1,266,1 +"Logamax Plus, GB192, Condens GC9000, Greenstar ErP",boiler,208,boilhystoff,hysteresis off temperature,int8 (>=0<=20),C,true,number.boiler_hysteresis_off_temperature,number.boiler_boilhystoff,6,0,1,267,1 +"Logamax Plus, GB192, Condens GC9000, Greenstar ErP",boiler,208,boil2hyston,hysteresis stage 2 on temperature,int8 (>=-20<=0),C,true,number.boiler_hysteresis_stage_2_on_temperature,number.boiler_boil2hyston,6,0,1,268,1 +"Logamax Plus, GB192, Condens GC9000, Greenstar ErP",boiler,208,boil2hystoff,hysteresis stage 2 off temperature,int8 (>=0<=20),C,true,number.boiler_hysteresis_stage_2_off_temperature,number.boiler_boil2hystoff,6,0,1,269,1 +"Logamax Plus, GB192, Condens GC9000, Greenstar ErP",boiler,208,curveon,heatingcurve on,boolean (>=0<=0), ,true,switch.boiler_heatingcurve_on,switch.boiler_curveon,6,0,1,270,1 +"Logamax Plus, GB192, Condens GC9000, Greenstar ErP",boiler,208,curvebase,heatingcurve base,uint8 (>=20<=90),C,true,number.boiler_heatingcurve_base,number.boiler_curvebase,6,0,1,271,1 +"Logamax Plus, GB192, Condens GC9000, Greenstar ErP",boiler,208,curveend,heatingcurve end,uint8 (>=20<=90),C,true,number.boiler_heatingcurve_end,number.boiler_curveend,6,0,1,272,1 +"Logamax Plus, GB192, Condens GC9000, Greenstar ErP",boiler,208,summertemp,summer temperature,uint8 (>=0<=45),C,true,number.boiler_summer_temperature,number.boiler_summertemp,6,0,1,273,1 +"Logamax Plus, GB192, Condens GC9000, Greenstar ErP",boiler,208,nofrostmode,nofrost mode,boolean (>=0<=0), ,true,switch.boiler_nofrost_mode,switch.boiler_nofrostmode,6,0,1,274,1 +"Logamax Plus, GB192, Condens GC9000, Greenstar ErP",boiler,208,nofrosttemp,nofrost temperature,uint8 (>=0<=10),C,true,number.boiler_nofrost_temperature,number.boiler_nofrosttemp,6,0,1,275,1 "Logamax Plus, GB192, Condens GC9000, Greenstar ErP",boiler,208,heatingactivated,heating activated,boolean (>=0<=0), ,true,switch.boiler_heating_activated,switch.boiler_heatingactivated,6,0,1,14,1 "Logamax Plus, GB192, Condens GC9000, Greenstar ErP",boiler,208,heatingtemp,heating temperature,uint8 (>=0<=90),C,true,number.boiler_heating_temperature,number.boiler_heatingtemp,6,0,1,15,1 "Logamax Plus, GB192, Condens GC9000, Greenstar ErP",boiler,208,heatingpump,heating pump,boolean, ,false,binary_sensor.boiler_heating_pump,binary_sensor.boiler_heatingpump,6,0,1,16,1 @@ -3475,18 +3501,19 @@ device name,device type,product id,shortname,fullname,type [options...] \| (min/ "Logamax Plus, GB192, Condens GC9000, Greenstar ErP",boiler,208,maintenancedate,next maintenance date,string (>=0<=0), ,true,sensor.boiler_next_maintenance_date,sensor.boiler_maintenancedate,6,0,1,72,6 "Logamax Plus, GB192, Condens GC9000, Greenstar ErP",boiler,208,emergencyops,emergency operation,boolean (>=0<=0), ,true,switch.boiler_emergency_operation,switch.boiler_emergencyops,6,0,1,78,1 "Logamax Plus, GB192, Condens GC9000, Greenstar ErP",boiler,208,emergencytemp,emergency temperature,uint8 (>=15<=70),C,true,number.boiler_emergency_temperature,number.boiler_emergencytemp,6,0,1,79,1 -"Logamax Plus, GB192, Condens GC9000, Greenstar ErP",boiler,208,pc0flow,Flow PC0,int16,l/h,false,sensor.boiler_Flow_PC0,sensor.boiler_pc0flow,6,0,1,80,1 -"Logamax Plus, GB192, Condens GC9000, Greenstar ErP",boiler,208,pc1flow,Flow PC1,int16,l/h,false,sensor.boiler_Flow_PC1,sensor.boiler_pc1flow,6,0,1,81,1 -"Logamax Plus, GB192, Condens GC9000, Greenstar ErP",boiler,208,pc1on,PC1,boolean, ,false,binary_sensor.boiler_PC1,binary_sensor.boiler_pc1on,6,0,1,82,1 -"Logamax Plus, GB192, Condens GC9000, Greenstar ErP",boiler,208,pc1rate,PC1 rate,uint8,%,false,sensor.boiler_PC1_rate,sensor.boiler_pc1rate,6,0,1,83,1 -"Logamax Plus, GB192, Condens GC9000, Greenstar ErP",boiler,208,pumpkickhour,pump kick hour,uint8 (>=0<=23),hours,true,number.boiler_pump_kick_hour,number.boiler_pumpkickhour,6,0,1,84,1 -"Logamax Plus, GB192, Condens GC9000, Greenstar ErP",boiler,208,pumpkickday,pump kick day,enum [mo\|tu\|we\|th\|fr\|sa\|su\|all] (>=0<=0), ,true,select.boiler_pump_kick_day,select.boiler_pumpkickday,6,0,1,85,1 -"Logamax Plus, GB192, Condens GC9000, Greenstar ErP",boiler,208,pumpkickdelay,pump kick delay,uint16 (>=0<=32767),minutes,true,number.boiler_pump_kick_delay,number.boiler_pumpkickdelay,6,0,1,86,1 -"Logamax Plus, GB192, Condens GC9000, Greenstar ErP",boiler,208,meterheat,meter heating,uint24,kWh,false,sensor.boiler_meter_heating,sensor.boiler_meterheat,6,0,1/10,100,2 +"Logamax Plus, GB192, Condens GC9000, Greenstar ErP",boiler,208,pc0lpm,Flow PC0,uint16,l/min,false,sensor.boiler_Flow_PC0,sensor.boiler_pc0lpm,6,0,1/10,80,1 +"Logamax Plus, GB192, Condens GC9000, Greenstar ErP",boiler,208,pc0flow,Flow PC0,uint16,l/h,false,sensor.boiler_Flow_PC0,sensor.boiler_pc0flow,6,0,1,81,1 +"Logamax Plus, GB192, Condens GC9000, Greenstar ErP",boiler,208,pc1flow,Flow PC1,uint16,l/h,false,sensor.boiler_Flow_PC1,sensor.boiler_pc1flow,6,0,1,82,1 +"Logamax Plus, GB192, Condens GC9000, Greenstar ErP",boiler,208,pc1on,PC1,boolean, ,false,binary_sensor.boiler_PC1,binary_sensor.boiler_pc1on,6,0,1,83,1 +"Logamax Plus, GB192, Condens GC9000, Greenstar ErP",boiler,208,pc1rate,PC1 rate,uint8,%,false,sensor.boiler_PC1_rate,sensor.boiler_pc1rate,6,0,1,84,1 +"Logamax Plus, GB192, Condens GC9000, Greenstar ErP",boiler,208,pumpkickhour,pump kick hour,uint8 (>=0<=23),hours,true,number.boiler_pump_kick_hour,number.boiler_pumpkickhour,6,0,1,85,1 +"Logamax Plus, GB192, Condens GC9000, Greenstar ErP",boiler,208,pumpkickday,pump kick day,enum [mo\|tu\|we\|th\|fr\|sa\|su\|all] (>=0<=0), ,true,select.boiler_pump_kick_day,select.boiler_pumpkickday,6,0,1,86,1 +"Logamax Plus, GB192, Condens GC9000, Greenstar ErP",boiler,208,pumpkickdelay,pump kick delay,uint16 (>=0<=32767),minutes,true,number.boiler_pump_kick_delay,number.boiler_pumpkickdelay,6,0,1,87,1 +"Logamax Plus, GB192, Condens GC9000, Greenstar ErP",boiler,208,meterheat,meter heating,uint24,kWh,false,sensor.boiler_meter_heating,sensor.boiler_meterheat,6,0,1/10,101,2 "Logamax Plus, GB192, Condens GC9000, Greenstar ErP",boiler,208,dhw.meter,meter,uint24,kWh,false,sensor.boiler_dhw_meter,sensor.boiler_dhw_meter,6,9,1/10,2,2 -"Logamax Plus, GB192, Condens GC9000, Greenstar ErP",boiler,208,gasmeterheat,gas meter heating,uint24,kWh,false,sensor.boiler_gas_meter_heating,sensor.boiler_gasmeterheat,6,0,1/10,275,2 +"Logamax Plus, GB192, Condens GC9000, Greenstar ErP",boiler,208,gasmeterheat,gas meter heating,uint24,kWh,false,sensor.boiler_gas_meter_heating,sensor.boiler_gasmeterheat,6,0,1/10,276,2 "Logamax Plus, GB192, Condens GC9000, Greenstar ErP",boiler,208,dhw.gasmeter,gas meter,uint24,kWh,false,sensor.boiler_dhw_gas_meter,sensor.boiler_dhw_gasmeter,6,9,1/10,71,2 -"Logamax Plus, GB192, Condens GC9000, Greenstar ErP",boiler,208,nrgheat2,energy heating 2,uint24,kWh,false,sensor.boiler_energy_heating_2,sensor.boiler_nrgheat2,6,0,1/10,277,2 +"Logamax Plus, GB192, Condens GC9000, Greenstar ErP",boiler,208,nrgheat2,energy heating 2,uint24,kWh,false,sensor.boiler_energy_heating_2,sensor.boiler_nrgheat2,6,0,1/10,278,2 "Logamax Plus, GB192, Condens GC9000, Greenstar ErP",boiler,208,dhw.nrg2,energy 2,uint24,kWh,false,sensor.boiler_dhw_energy_2,sensor.boiler_dhw_nrg2,6,9,1/10,73,2 "Logamax Plus, GB192, Condens GC9000, Greenstar ErP",boiler,208,dhw.tapactivated,turn on/off,boolean (>=0<=0), ,true,switch.boiler_dhw_turn_on/off,switch.boiler_dhw_tapactivated,6,9,1,28,1 "Logamax Plus, GB192, Condens GC9000, Greenstar ErP",boiler,208,dhw.settemp,set temperature,uint8,C,false,sensor.boiler_dhw_set_temperature,sensor.boiler_dhw_settemp,6,9,1,29,1 @@ -3529,9 +3556,9 @@ device name,device type,product id,shortname,fullname,type [options...] \| (min/ "Logamax Plus, GB192, Condens GC9000, Greenstar ErP",boiler,208,dhw.dhwprio,dhw priority,boolean (>=0<=0), ,true,switch.boiler_dhw_dhw_priority,switch.boiler_dhw_dhwprio,6,9,1,66,1 "Logamax Plus, GB192, Condens GC9000, Greenstar ErP",boiler,208,dhw.starts,starts,uint24, ,false,sensor.boiler_dhw_starts,sensor.boiler_dhw_starts,6,9,1,67,2 "Logamax Plus, GB192, Condens GC9000, Greenstar ErP",boiler,208,dhw.workm,active time,time,minutes,false,sensor.boiler_dhw_active_time,sensor.boiler_dhw_workm,6,9,1,69,2 -"Logamax Plus, GB192, Condens GC9000, Greenstar ErP",boiler,208,nompower,nominal Power,uint8 (>=0<=0),kW,true,number.boiler_nominal_Power,number.boiler_nompower,6,0,1,279,1 -"Logamax Plus, GB192, Condens GC9000, Greenstar ErP",boiler,208,nrgtotal,total energy,uint24,kWh,false,sensor.boiler_total_energy,sensor.boiler_nrgtotal,6,0,1/100,88,2 -"Logamax Plus, GB192, Condens GC9000, Greenstar ErP",boiler,208,nrgheat,energy heating,uint24 (>=0<=10000000),kWh,true,number.boiler_energy_heating,number.boiler_nrgheat,6,0,1/100,90,2 +"Logamax Plus, GB192, Condens GC9000, Greenstar ErP",boiler,208,nompower,nominal Power,uint8 (>=0<=0),kW,true,number.boiler_nominal_Power,number.boiler_nompower,6,0,1,280,1 +"Logamax Plus, GB192, Condens GC9000, Greenstar ErP",boiler,208,nrgtotal,total energy,uint24,kWh,false,sensor.boiler_total_energy,sensor.boiler_nrgtotal,6,0,1/100,89,2 +"Logamax Plus, GB192, Condens GC9000, Greenstar ErP",boiler,208,nrgheat,energy heating,uint24 (>=0<=10000000),kWh,true,number.boiler_energy_heating,number.boiler_nrgheat,6,0,1/100,91,2 "Logamax Plus, GB192, Condens GC9000, Greenstar ErP",boiler,208,dhw.nrg,energy,uint24 (>=0<=10000000),kWh,true,number.boiler_dhw_energy,number.boiler_dhw_nrg,6,9,1/100,0,2 "Cascade MC400",boiler,210,reset,reset,cmd [-\|maintenance\|error\|history\|message\|hp error\|burner starts\|factory] (>=0<=0), ,true,sensor.boiler_reset,sensor.boiler_reset,6,0,1,0,1 "Cascade MC400",boiler,210,chimneysweeper,chimney sweeper,cmd [off\|on] (>=0<=0), ,true,sensor.boiler_chimney_sweeper,sensor.boiler_chimneysweeper,6,0,1,1,1 @@ -3547,28 +3574,28 @@ device name,device type,product id,shortname,fullname,type [options...] \| (min/ "Cascade MC400",boiler,210,syspress,system pressure,uint8,bar,false,sensor.boiler_system_pressure,sensor.boiler_syspress,6,0,1/10,11,1 "Cascade MC400",boiler,210,boiltemp,actual boiler temperature,uint16,C,false,sensor.boiler_actual_boiler_temperature,sensor.boiler_boiltemp,6,0,1/10,12,1 "Cascade MC400",boiler,210,headertemp,low loss header,uint16,C,false,sensor.boiler_low_loss_header,sensor.boiler_headertemp,6,0,1/10,13,1 -"Cascade MC400",boiler,210,exhausttemp,exhaust temperature,uint16,C,false,sensor.boiler_exhaust_temperature,sensor.boiler_exhausttemp,6,0,1/10,253,1 -"Cascade MC400",boiler,210,burngas,gas,boolean, ,false,binary_sensor.boiler_gas,binary_sensor.boiler_burngas,6,0,1,254,1 -"Cascade MC400",boiler,210,burngas2,gas stage 2,boolean, ,false,binary_sensor.boiler_gas_stage_2,binary_sensor.boiler_burngas2,6,0,1,255,1 -"Cascade MC400",boiler,210,flamecurr,flame current,uint16,µA,false,sensor.boiler_flame_current,sensor.boiler_flamecurr,6,0,1/10,256,1 -"Cascade MC400",boiler,210,fanwork,fan,boolean, ,false,binary_sensor.boiler_fan,binary_sensor.boiler_fanwork,6,0,1,257,1 -"Cascade MC400",boiler,210,ignwork,ignition,boolean, ,false,binary_sensor.boiler_ignition,binary_sensor.boiler_ignwork,6,0,1,258,1 -"Cascade MC400",boiler,210,oilpreheat,oil preheating,boolean, ,false,binary_sensor.boiler_oil_preheating,binary_sensor.boiler_oilpreheat,6,0,1,259,1 -"Cascade MC400",boiler,210,burnminpower,burner min power,uint8 (>=0<=0),%,true,number.boiler_burner_min_power,number.boiler_burnminpower,6,0,1,260,1 -"Cascade MC400",boiler,210,burnmaxpower,burner max power,uint8 (>=0<=254),%,true,number.boiler_burner_max_power,number.boiler_burnmaxpower,6,0,1,261,1 -"Cascade MC400",boiler,210,burnminperiod,burner min period,uint8 (>=0<=120),minutes,true,number.boiler_burner_min_period,number.boiler_burnminperiod,6,0,1,262,1 -"Cascade MC400",boiler,210,absburnpow,burner current power (absolute),uint8,%,false,sensor.boiler_burner_current_power_(absolute),sensor.boiler_absburnpow,6,0,1,263,1 -"Cascade MC400",boiler,210,heatblock,Heatblock temperature,uint16,C,false,sensor.boiler_Heatblock_temperature,sensor.boiler_heatblock,6,0,1/10,264,1 -"Cascade MC400",boiler,210,boilhyston,hysteresis on temperature,int8 (>=-20<=0),C,true,number.boiler_hysteresis_on_temperature,number.boiler_boilhyston,6,0,1,265,1 -"Cascade MC400",boiler,210,boilhystoff,hysteresis off temperature,int8 (>=0<=20),C,true,number.boiler_hysteresis_off_temperature,number.boiler_boilhystoff,6,0,1,266,1 -"Cascade MC400",boiler,210,boil2hyston,hysteresis stage 2 on temperature,int8 (>=-20<=0),C,true,number.boiler_hysteresis_stage_2_on_temperature,number.boiler_boil2hyston,6,0,1,267,1 -"Cascade MC400",boiler,210,boil2hystoff,hysteresis stage 2 off temperature,int8 (>=0<=20),C,true,number.boiler_hysteresis_stage_2_off_temperature,number.boiler_boil2hystoff,6,0,1,268,1 -"Cascade MC400",boiler,210,curveon,heatingcurve on,boolean (>=0<=0), ,true,switch.boiler_heatingcurve_on,switch.boiler_curveon,6,0,1,269,1 -"Cascade MC400",boiler,210,curvebase,heatingcurve base,uint8 (>=20<=90),C,true,number.boiler_heatingcurve_base,number.boiler_curvebase,6,0,1,270,1 -"Cascade MC400",boiler,210,curveend,heatingcurve end,uint8 (>=20<=90),C,true,number.boiler_heatingcurve_end,number.boiler_curveend,6,0,1,271,1 -"Cascade MC400",boiler,210,summertemp,summer temperature,uint8 (>=0<=45),C,true,number.boiler_summer_temperature,number.boiler_summertemp,6,0,1,272,1 -"Cascade MC400",boiler,210,nofrostmode,nofrost mode,boolean (>=0<=0), ,true,switch.boiler_nofrost_mode,switch.boiler_nofrostmode,6,0,1,273,1 -"Cascade MC400",boiler,210,nofrosttemp,nofrost temperature,uint8 (>=0<=10),C,true,number.boiler_nofrost_temperature,number.boiler_nofrosttemp,6,0,1,274,1 +"Cascade MC400",boiler,210,exhausttemp,exhaust temperature,uint16,C,false,sensor.boiler_exhaust_temperature,sensor.boiler_exhausttemp,6,0,1/10,254,1 +"Cascade MC400",boiler,210,burngas,gas,boolean, ,false,binary_sensor.boiler_gas,binary_sensor.boiler_burngas,6,0,1,255,1 +"Cascade MC400",boiler,210,burngas2,gas stage 2,boolean, ,false,binary_sensor.boiler_gas_stage_2,binary_sensor.boiler_burngas2,6,0,1,256,1 +"Cascade MC400",boiler,210,flamecurr,flame current,uint16,µA,false,sensor.boiler_flame_current,sensor.boiler_flamecurr,6,0,1/10,257,1 +"Cascade MC400",boiler,210,fanwork,fan,boolean, ,false,binary_sensor.boiler_fan,binary_sensor.boiler_fanwork,6,0,1,258,1 +"Cascade MC400",boiler,210,ignwork,ignition,boolean, ,false,binary_sensor.boiler_ignition,binary_sensor.boiler_ignwork,6,0,1,259,1 +"Cascade MC400",boiler,210,oilpreheat,oil preheating,boolean, ,false,binary_sensor.boiler_oil_preheating,binary_sensor.boiler_oilpreheat,6,0,1,260,1 +"Cascade MC400",boiler,210,burnminpower,burner min power,uint8 (>=0<=0),%,true,number.boiler_burner_min_power,number.boiler_burnminpower,6,0,1,261,1 +"Cascade MC400",boiler,210,burnmaxpower,burner max power,uint8 (>=0<=254),%,true,number.boiler_burner_max_power,number.boiler_burnmaxpower,6,0,1,262,1 +"Cascade MC400",boiler,210,burnminperiod,burner min period,uint8 (>=0<=120),minutes,true,number.boiler_burner_min_period,number.boiler_burnminperiod,6,0,1,263,1 +"Cascade MC400",boiler,210,absburnpow,burner current power (absolute),uint8,%,false,sensor.boiler_burner_current_power_(absolute),sensor.boiler_absburnpow,6,0,1,264,1 +"Cascade MC400",boiler,210,heatblock,Heatblock temperature,uint16,C,false,sensor.boiler_Heatblock_temperature,sensor.boiler_heatblock,6,0,1/10,265,1 +"Cascade MC400",boiler,210,boilhyston,hysteresis on temperature,int8 (>=-20<=0),C,true,number.boiler_hysteresis_on_temperature,number.boiler_boilhyston,6,0,1,266,1 +"Cascade MC400",boiler,210,boilhystoff,hysteresis off temperature,int8 (>=0<=20),C,true,number.boiler_hysteresis_off_temperature,number.boiler_boilhystoff,6,0,1,267,1 +"Cascade MC400",boiler,210,boil2hyston,hysteresis stage 2 on temperature,int8 (>=-20<=0),C,true,number.boiler_hysteresis_stage_2_on_temperature,number.boiler_boil2hyston,6,0,1,268,1 +"Cascade MC400",boiler,210,boil2hystoff,hysteresis stage 2 off temperature,int8 (>=0<=20),C,true,number.boiler_hysteresis_stage_2_off_temperature,number.boiler_boil2hystoff,6,0,1,269,1 +"Cascade MC400",boiler,210,curveon,heatingcurve on,boolean (>=0<=0), ,true,switch.boiler_heatingcurve_on,switch.boiler_curveon,6,0,1,270,1 +"Cascade MC400",boiler,210,curvebase,heatingcurve base,uint8 (>=20<=90),C,true,number.boiler_heatingcurve_base,number.boiler_curvebase,6,0,1,271,1 +"Cascade MC400",boiler,210,curveend,heatingcurve end,uint8 (>=20<=90),C,true,number.boiler_heatingcurve_end,number.boiler_curveend,6,0,1,272,1 +"Cascade MC400",boiler,210,summertemp,summer temperature,uint8 (>=0<=45),C,true,number.boiler_summer_temperature,number.boiler_summertemp,6,0,1,273,1 +"Cascade MC400",boiler,210,nofrostmode,nofrost mode,boolean (>=0<=0), ,true,switch.boiler_nofrost_mode,switch.boiler_nofrostmode,6,0,1,274,1 +"Cascade MC400",boiler,210,nofrosttemp,nofrost temperature,uint8 (>=0<=10),C,true,number.boiler_nofrost_temperature,number.boiler_nofrosttemp,6,0,1,275,1 "Cascade MC400",boiler,210,heatingactivated,heating activated,boolean (>=0<=0), ,true,switch.boiler_heating_activated,switch.boiler_heatingactivated,6,0,1,14,1 "Cascade MC400",boiler,210,heatingtemp,heating temperature,uint8 (>=0<=90),C,true,number.boiler_heating_temperature,number.boiler_heatingtemp,6,0,1,15,1 "Cascade MC400",boiler,210,heatingpump,heating pump,boolean, ,false,binary_sensor.boiler_heating_pump,binary_sensor.boiler_heatingpump,6,0,1,16,1 @@ -3595,18 +3622,19 @@ device name,device type,product id,shortname,fullname,type [options...] \| (min/ "Cascade MC400",boiler,210,maintenancedate,next maintenance date,string (>=0<=0), ,true,sensor.boiler_next_maintenance_date,sensor.boiler_maintenancedate,6,0,1,72,6 "Cascade MC400",boiler,210,emergencyops,emergency operation,boolean (>=0<=0), ,true,switch.boiler_emergency_operation,switch.boiler_emergencyops,6,0,1,78,1 "Cascade MC400",boiler,210,emergencytemp,emergency temperature,uint8 (>=15<=70),C,true,number.boiler_emergency_temperature,number.boiler_emergencytemp,6,0,1,79,1 -"Cascade MC400",boiler,210,pc0flow,Flow PC0,int16,l/h,false,sensor.boiler_Flow_PC0,sensor.boiler_pc0flow,6,0,1,80,1 -"Cascade MC400",boiler,210,pc1flow,Flow PC1,int16,l/h,false,sensor.boiler_Flow_PC1,sensor.boiler_pc1flow,6,0,1,81,1 -"Cascade MC400",boiler,210,pc1on,PC1,boolean, ,false,binary_sensor.boiler_PC1,binary_sensor.boiler_pc1on,6,0,1,82,1 -"Cascade MC400",boiler,210,pc1rate,PC1 rate,uint8,%,false,sensor.boiler_PC1_rate,sensor.boiler_pc1rate,6,0,1,83,1 -"Cascade MC400",boiler,210,pumpkickhour,pump kick hour,uint8 (>=0<=23),hours,true,number.boiler_pump_kick_hour,number.boiler_pumpkickhour,6,0,1,84,1 -"Cascade MC400",boiler,210,pumpkickday,pump kick day,enum [mo\|tu\|we\|th\|fr\|sa\|su\|all] (>=0<=0), ,true,select.boiler_pump_kick_day,select.boiler_pumpkickday,6,0,1,85,1 -"Cascade MC400",boiler,210,pumpkickdelay,pump kick delay,uint16 (>=0<=32767),minutes,true,number.boiler_pump_kick_delay,number.boiler_pumpkickdelay,6,0,1,86,1 -"Cascade MC400",boiler,210,meterheat,meter heating,uint24,kWh,false,sensor.boiler_meter_heating,sensor.boiler_meterheat,6,0,1/10,100,2 +"Cascade MC400",boiler,210,pc0lpm,Flow PC0,uint16,l/min,false,sensor.boiler_Flow_PC0,sensor.boiler_pc0lpm,6,0,1/10,80,1 +"Cascade MC400",boiler,210,pc0flow,Flow PC0,uint16,l/h,false,sensor.boiler_Flow_PC0,sensor.boiler_pc0flow,6,0,1,81,1 +"Cascade MC400",boiler,210,pc1flow,Flow PC1,uint16,l/h,false,sensor.boiler_Flow_PC1,sensor.boiler_pc1flow,6,0,1,82,1 +"Cascade MC400",boiler,210,pc1on,PC1,boolean, ,false,binary_sensor.boiler_PC1,binary_sensor.boiler_pc1on,6,0,1,83,1 +"Cascade MC400",boiler,210,pc1rate,PC1 rate,uint8,%,false,sensor.boiler_PC1_rate,sensor.boiler_pc1rate,6,0,1,84,1 +"Cascade MC400",boiler,210,pumpkickhour,pump kick hour,uint8 (>=0<=23),hours,true,number.boiler_pump_kick_hour,number.boiler_pumpkickhour,6,0,1,85,1 +"Cascade MC400",boiler,210,pumpkickday,pump kick day,enum [mo\|tu\|we\|th\|fr\|sa\|su\|all] (>=0<=0), ,true,select.boiler_pump_kick_day,select.boiler_pumpkickday,6,0,1,86,1 +"Cascade MC400",boiler,210,pumpkickdelay,pump kick delay,uint16 (>=0<=32767),minutes,true,number.boiler_pump_kick_delay,number.boiler_pumpkickdelay,6,0,1,87,1 +"Cascade MC400",boiler,210,meterheat,meter heating,uint24,kWh,false,sensor.boiler_meter_heating,sensor.boiler_meterheat,6,0,1/10,101,2 "Cascade MC400",boiler,210,dhw.meter,meter,uint24,kWh,false,sensor.boiler_dhw_meter,sensor.boiler_dhw_meter,6,9,1/10,2,2 -"Cascade MC400",boiler,210,gasmeterheat,gas meter heating,uint24,kWh,false,sensor.boiler_gas_meter_heating,sensor.boiler_gasmeterheat,6,0,1/10,275,2 +"Cascade MC400",boiler,210,gasmeterheat,gas meter heating,uint24,kWh,false,sensor.boiler_gas_meter_heating,sensor.boiler_gasmeterheat,6,0,1/10,276,2 "Cascade MC400",boiler,210,dhw.gasmeter,gas meter,uint24,kWh,false,sensor.boiler_dhw_gas_meter,sensor.boiler_dhw_gasmeter,6,9,1/10,71,2 -"Cascade MC400",boiler,210,nrgheat2,energy heating 2,uint24,kWh,false,sensor.boiler_energy_heating_2,sensor.boiler_nrgheat2,6,0,1/10,277,2 +"Cascade MC400",boiler,210,nrgheat2,energy heating 2,uint24,kWh,false,sensor.boiler_energy_heating_2,sensor.boiler_nrgheat2,6,0,1/10,278,2 "Cascade MC400",boiler,210,dhw.nrg2,energy 2,uint24,kWh,false,sensor.boiler_dhw_energy_2,sensor.boiler_dhw_nrg2,6,9,1/10,73,2 "Cascade MC400",boiler,210,dhw.tapactivated,turn on/off,boolean (>=0<=0), ,true,switch.boiler_dhw_turn_on/off,switch.boiler_dhw_tapactivated,6,9,1,28,1 "Cascade MC400",boiler,210,dhw.settemp,set temperature,uint8,C,false,sensor.boiler_dhw_set_temperature,sensor.boiler_dhw_settemp,6,9,1,29,1 @@ -3649,9 +3677,9 @@ device name,device type,product id,shortname,fullname,type [options...] \| (min/ "Cascade MC400",boiler,210,dhw.dhwprio,dhw priority,boolean (>=0<=0), ,true,switch.boiler_dhw_dhw_priority,switch.boiler_dhw_dhwprio,6,9,1,66,1 "Cascade MC400",boiler,210,dhw.starts,starts,uint24, ,false,sensor.boiler_dhw_starts,sensor.boiler_dhw_starts,6,9,1,67,2 "Cascade MC400",boiler,210,dhw.workm,active time,time,minutes,false,sensor.boiler_dhw_active_time,sensor.boiler_dhw_workm,6,9,1,69,2 -"Cascade MC400",boiler,210,nompower,nominal Power,uint8 (>=0<=0),kW,true,number.boiler_nominal_Power,number.boiler_nompower,6,0,1,279,1 -"Cascade MC400",boiler,210,nrgtotal,total energy,uint24,kWh,false,sensor.boiler_total_energy,sensor.boiler_nrgtotal,6,0,1/100,88,2 -"Cascade MC400",boiler,210,nrgheat,energy heating,uint24 (>=0<=10000000),kWh,true,number.boiler_energy_heating,number.boiler_nrgheat,6,0,1/100,90,2 +"Cascade MC400",boiler,210,nompower,nominal Power,uint8 (>=0<=0),kW,true,number.boiler_nominal_Power,number.boiler_nompower,6,0,1,280,1 +"Cascade MC400",boiler,210,nrgtotal,total energy,uint24,kWh,false,sensor.boiler_total_energy,sensor.boiler_nrgtotal,6,0,1/100,89,2 +"Cascade MC400",boiler,210,nrgheat,energy heating,uint24 (>=0<=10000000),kWh,true,number.boiler_energy_heating,number.boiler_nrgheat,6,0,1/100,91,2 "Cascade MC400",boiler,210,dhw.nrg,energy,uint24 (>=0<=10000000),kWh,true,number.boiler_dhw_energy,number.boiler_dhw_nrg,6,9,1/100,0,2 "EasyControl Adapter",boiler,211,reset,reset,cmd [-\|maintenance\|error\|history\|message\|hp error\|burner starts\|factory] (>=0<=0), ,true,sensor.boiler_reset,sensor.boiler_reset,6,0,1,0,1 "EasyControl Adapter",boiler,211,chimneysweeper,chimney sweeper,cmd [off\|on] (>=0<=0), ,true,sensor.boiler_chimney_sweeper,sensor.boiler_chimneysweeper,6,0,1,1,1 @@ -3667,28 +3695,28 @@ device name,device type,product id,shortname,fullname,type [options...] \| (min/ "EasyControl Adapter",boiler,211,syspress,system pressure,uint8,bar,false,sensor.boiler_system_pressure,sensor.boiler_syspress,6,0,1/10,11,1 "EasyControl Adapter",boiler,211,boiltemp,actual boiler temperature,uint16,C,false,sensor.boiler_actual_boiler_temperature,sensor.boiler_boiltemp,6,0,1/10,12,1 "EasyControl Adapter",boiler,211,headertemp,low loss header,uint16,C,false,sensor.boiler_low_loss_header,sensor.boiler_headertemp,6,0,1/10,13,1 -"EasyControl Adapter",boiler,211,exhausttemp,exhaust temperature,uint16,C,false,sensor.boiler_exhaust_temperature,sensor.boiler_exhausttemp,6,0,1/10,253,1 -"EasyControl Adapter",boiler,211,burngas,gas,boolean, ,false,binary_sensor.boiler_gas,binary_sensor.boiler_burngas,6,0,1,254,1 -"EasyControl Adapter",boiler,211,burngas2,gas stage 2,boolean, ,false,binary_sensor.boiler_gas_stage_2,binary_sensor.boiler_burngas2,6,0,1,255,1 -"EasyControl Adapter",boiler,211,flamecurr,flame current,uint16,µA,false,sensor.boiler_flame_current,sensor.boiler_flamecurr,6,0,1/10,256,1 -"EasyControl Adapter",boiler,211,fanwork,fan,boolean, ,false,binary_sensor.boiler_fan,binary_sensor.boiler_fanwork,6,0,1,257,1 -"EasyControl Adapter",boiler,211,ignwork,ignition,boolean, ,false,binary_sensor.boiler_ignition,binary_sensor.boiler_ignwork,6,0,1,258,1 -"EasyControl Adapter",boiler,211,oilpreheat,oil preheating,boolean, ,false,binary_sensor.boiler_oil_preheating,binary_sensor.boiler_oilpreheat,6,0,1,259,1 -"EasyControl Adapter",boiler,211,burnminpower,burner min power,uint8 (>=0<=0),%,true,number.boiler_burner_min_power,number.boiler_burnminpower,6,0,1,260,1 -"EasyControl Adapter",boiler,211,burnmaxpower,burner max power,uint8 (>=0<=254),%,true,number.boiler_burner_max_power,number.boiler_burnmaxpower,6,0,1,261,1 -"EasyControl Adapter",boiler,211,burnminperiod,burner min period,uint8 (>=0<=120),minutes,true,number.boiler_burner_min_period,number.boiler_burnminperiod,6,0,1,262,1 -"EasyControl Adapter",boiler,211,absburnpow,burner current power (absolute),uint8,%,false,sensor.boiler_burner_current_power_(absolute),sensor.boiler_absburnpow,6,0,1,263,1 -"EasyControl Adapter",boiler,211,heatblock,Heatblock temperature,uint16,C,false,sensor.boiler_Heatblock_temperature,sensor.boiler_heatblock,6,0,1/10,264,1 -"EasyControl Adapter",boiler,211,boilhyston,hysteresis on temperature,int8 (>=-20<=0),C,true,number.boiler_hysteresis_on_temperature,number.boiler_boilhyston,6,0,1,265,1 -"EasyControl Adapter",boiler,211,boilhystoff,hysteresis off temperature,int8 (>=0<=20),C,true,number.boiler_hysteresis_off_temperature,number.boiler_boilhystoff,6,0,1,266,1 -"EasyControl Adapter",boiler,211,boil2hyston,hysteresis stage 2 on temperature,int8 (>=-20<=0),C,true,number.boiler_hysteresis_stage_2_on_temperature,number.boiler_boil2hyston,6,0,1,267,1 -"EasyControl Adapter",boiler,211,boil2hystoff,hysteresis stage 2 off temperature,int8 (>=0<=20),C,true,number.boiler_hysteresis_stage_2_off_temperature,number.boiler_boil2hystoff,6,0,1,268,1 -"EasyControl Adapter",boiler,211,curveon,heatingcurve on,boolean (>=0<=0), ,true,switch.boiler_heatingcurve_on,switch.boiler_curveon,6,0,1,269,1 -"EasyControl Adapter",boiler,211,curvebase,heatingcurve base,uint8 (>=20<=90),C,true,number.boiler_heatingcurve_base,number.boiler_curvebase,6,0,1,270,1 -"EasyControl Adapter",boiler,211,curveend,heatingcurve end,uint8 (>=20<=90),C,true,number.boiler_heatingcurve_end,number.boiler_curveend,6,0,1,271,1 -"EasyControl Adapter",boiler,211,summertemp,summer temperature,uint8 (>=0<=45),C,true,number.boiler_summer_temperature,number.boiler_summertemp,6,0,1,272,1 -"EasyControl Adapter",boiler,211,nofrostmode,nofrost mode,boolean (>=0<=0), ,true,switch.boiler_nofrost_mode,switch.boiler_nofrostmode,6,0,1,273,1 -"EasyControl Adapter",boiler,211,nofrosttemp,nofrost temperature,uint8 (>=0<=10),C,true,number.boiler_nofrost_temperature,number.boiler_nofrosttemp,6,0,1,274,1 +"EasyControl Adapter",boiler,211,exhausttemp,exhaust temperature,uint16,C,false,sensor.boiler_exhaust_temperature,sensor.boiler_exhausttemp,6,0,1/10,254,1 +"EasyControl Adapter",boiler,211,burngas,gas,boolean, ,false,binary_sensor.boiler_gas,binary_sensor.boiler_burngas,6,0,1,255,1 +"EasyControl Adapter",boiler,211,burngas2,gas stage 2,boolean, ,false,binary_sensor.boiler_gas_stage_2,binary_sensor.boiler_burngas2,6,0,1,256,1 +"EasyControl Adapter",boiler,211,flamecurr,flame current,uint16,µA,false,sensor.boiler_flame_current,sensor.boiler_flamecurr,6,0,1/10,257,1 +"EasyControl Adapter",boiler,211,fanwork,fan,boolean, ,false,binary_sensor.boiler_fan,binary_sensor.boiler_fanwork,6,0,1,258,1 +"EasyControl Adapter",boiler,211,ignwork,ignition,boolean, ,false,binary_sensor.boiler_ignition,binary_sensor.boiler_ignwork,6,0,1,259,1 +"EasyControl Adapter",boiler,211,oilpreheat,oil preheating,boolean, ,false,binary_sensor.boiler_oil_preheating,binary_sensor.boiler_oilpreheat,6,0,1,260,1 +"EasyControl Adapter",boiler,211,burnminpower,burner min power,uint8 (>=0<=0),%,true,number.boiler_burner_min_power,number.boiler_burnminpower,6,0,1,261,1 +"EasyControl Adapter",boiler,211,burnmaxpower,burner max power,uint8 (>=0<=254),%,true,number.boiler_burner_max_power,number.boiler_burnmaxpower,6,0,1,262,1 +"EasyControl Adapter",boiler,211,burnminperiod,burner min period,uint8 (>=0<=120),minutes,true,number.boiler_burner_min_period,number.boiler_burnminperiod,6,0,1,263,1 +"EasyControl Adapter",boiler,211,absburnpow,burner current power (absolute),uint8,%,false,sensor.boiler_burner_current_power_(absolute),sensor.boiler_absburnpow,6,0,1,264,1 +"EasyControl Adapter",boiler,211,heatblock,Heatblock temperature,uint16,C,false,sensor.boiler_Heatblock_temperature,sensor.boiler_heatblock,6,0,1/10,265,1 +"EasyControl Adapter",boiler,211,boilhyston,hysteresis on temperature,int8 (>=-20<=0),C,true,number.boiler_hysteresis_on_temperature,number.boiler_boilhyston,6,0,1,266,1 +"EasyControl Adapter",boiler,211,boilhystoff,hysteresis off temperature,int8 (>=0<=20),C,true,number.boiler_hysteresis_off_temperature,number.boiler_boilhystoff,6,0,1,267,1 +"EasyControl Adapter",boiler,211,boil2hyston,hysteresis stage 2 on temperature,int8 (>=-20<=0),C,true,number.boiler_hysteresis_stage_2_on_temperature,number.boiler_boil2hyston,6,0,1,268,1 +"EasyControl Adapter",boiler,211,boil2hystoff,hysteresis stage 2 off temperature,int8 (>=0<=20),C,true,number.boiler_hysteresis_stage_2_off_temperature,number.boiler_boil2hystoff,6,0,1,269,1 +"EasyControl Adapter",boiler,211,curveon,heatingcurve on,boolean (>=0<=0), ,true,switch.boiler_heatingcurve_on,switch.boiler_curveon,6,0,1,270,1 +"EasyControl Adapter",boiler,211,curvebase,heatingcurve base,uint8 (>=20<=90),C,true,number.boiler_heatingcurve_base,number.boiler_curvebase,6,0,1,271,1 +"EasyControl Adapter",boiler,211,curveend,heatingcurve end,uint8 (>=20<=90),C,true,number.boiler_heatingcurve_end,number.boiler_curveend,6,0,1,272,1 +"EasyControl Adapter",boiler,211,summertemp,summer temperature,uint8 (>=0<=45),C,true,number.boiler_summer_temperature,number.boiler_summertemp,6,0,1,273,1 +"EasyControl Adapter",boiler,211,nofrostmode,nofrost mode,boolean (>=0<=0), ,true,switch.boiler_nofrost_mode,switch.boiler_nofrostmode,6,0,1,274,1 +"EasyControl Adapter",boiler,211,nofrosttemp,nofrost temperature,uint8 (>=0<=10),C,true,number.boiler_nofrost_temperature,number.boiler_nofrosttemp,6,0,1,275,1 "EasyControl Adapter",boiler,211,heatingactivated,heating activated,boolean (>=0<=0), ,true,switch.boiler_heating_activated,switch.boiler_heatingactivated,6,0,1,14,1 "EasyControl Adapter",boiler,211,heatingtemp,heating temperature,uint8 (>=0<=90),C,true,number.boiler_heating_temperature,number.boiler_heatingtemp,6,0,1,15,1 "EasyControl Adapter",boiler,211,heatingpump,heating pump,boolean, ,false,binary_sensor.boiler_heating_pump,binary_sensor.boiler_heatingpump,6,0,1,16,1 @@ -3715,18 +3743,19 @@ device name,device type,product id,shortname,fullname,type [options...] \| (min/ "EasyControl Adapter",boiler,211,maintenancedate,next maintenance date,string (>=0<=0), ,true,sensor.boiler_next_maintenance_date,sensor.boiler_maintenancedate,6,0,1,72,6 "EasyControl Adapter",boiler,211,emergencyops,emergency operation,boolean (>=0<=0), ,true,switch.boiler_emergency_operation,switch.boiler_emergencyops,6,0,1,78,1 "EasyControl Adapter",boiler,211,emergencytemp,emergency temperature,uint8 (>=15<=70),C,true,number.boiler_emergency_temperature,number.boiler_emergencytemp,6,0,1,79,1 -"EasyControl Adapter",boiler,211,pc0flow,Flow PC0,int16,l/h,false,sensor.boiler_Flow_PC0,sensor.boiler_pc0flow,6,0,1,80,1 -"EasyControl Adapter",boiler,211,pc1flow,Flow PC1,int16,l/h,false,sensor.boiler_Flow_PC1,sensor.boiler_pc1flow,6,0,1,81,1 -"EasyControl Adapter",boiler,211,pc1on,PC1,boolean, ,false,binary_sensor.boiler_PC1,binary_sensor.boiler_pc1on,6,0,1,82,1 -"EasyControl Adapter",boiler,211,pc1rate,PC1 rate,uint8,%,false,sensor.boiler_PC1_rate,sensor.boiler_pc1rate,6,0,1,83,1 -"EasyControl Adapter",boiler,211,pumpkickhour,pump kick hour,uint8 (>=0<=23),hours,true,number.boiler_pump_kick_hour,number.boiler_pumpkickhour,6,0,1,84,1 -"EasyControl Adapter",boiler,211,pumpkickday,pump kick day,enum [mo\|tu\|we\|th\|fr\|sa\|su\|all] (>=0<=0), ,true,select.boiler_pump_kick_day,select.boiler_pumpkickday,6,0,1,85,1 -"EasyControl Adapter",boiler,211,pumpkickdelay,pump kick delay,uint16 (>=0<=32767),minutes,true,number.boiler_pump_kick_delay,number.boiler_pumpkickdelay,6,0,1,86,1 -"EasyControl Adapter",boiler,211,meterheat,meter heating,uint24,kWh,false,sensor.boiler_meter_heating,sensor.boiler_meterheat,6,0,1/10,100,2 +"EasyControl Adapter",boiler,211,pc0lpm,Flow PC0,uint16,l/min,false,sensor.boiler_Flow_PC0,sensor.boiler_pc0lpm,6,0,1/10,80,1 +"EasyControl Adapter",boiler,211,pc0flow,Flow PC0,uint16,l/h,false,sensor.boiler_Flow_PC0,sensor.boiler_pc0flow,6,0,1,81,1 +"EasyControl Adapter",boiler,211,pc1flow,Flow PC1,uint16,l/h,false,sensor.boiler_Flow_PC1,sensor.boiler_pc1flow,6,0,1,82,1 +"EasyControl Adapter",boiler,211,pc1on,PC1,boolean, ,false,binary_sensor.boiler_PC1,binary_sensor.boiler_pc1on,6,0,1,83,1 +"EasyControl Adapter",boiler,211,pc1rate,PC1 rate,uint8,%,false,sensor.boiler_PC1_rate,sensor.boiler_pc1rate,6,0,1,84,1 +"EasyControl Adapter",boiler,211,pumpkickhour,pump kick hour,uint8 (>=0<=23),hours,true,number.boiler_pump_kick_hour,number.boiler_pumpkickhour,6,0,1,85,1 +"EasyControl Adapter",boiler,211,pumpkickday,pump kick day,enum [mo\|tu\|we\|th\|fr\|sa\|su\|all] (>=0<=0), ,true,select.boiler_pump_kick_day,select.boiler_pumpkickday,6,0,1,86,1 +"EasyControl Adapter",boiler,211,pumpkickdelay,pump kick delay,uint16 (>=0<=32767),minutes,true,number.boiler_pump_kick_delay,number.boiler_pumpkickdelay,6,0,1,87,1 +"EasyControl Adapter",boiler,211,meterheat,meter heating,uint24,kWh,false,sensor.boiler_meter_heating,sensor.boiler_meterheat,6,0,1/10,101,2 "EasyControl Adapter",boiler,211,dhw.meter,meter,uint24,kWh,false,sensor.boiler_dhw_meter,sensor.boiler_dhw_meter,6,9,1/10,2,2 -"EasyControl Adapter",boiler,211,gasmeterheat,gas meter heating,uint24,kWh,false,sensor.boiler_gas_meter_heating,sensor.boiler_gasmeterheat,6,0,1/10,275,2 +"EasyControl Adapter",boiler,211,gasmeterheat,gas meter heating,uint24,kWh,false,sensor.boiler_gas_meter_heating,sensor.boiler_gasmeterheat,6,0,1/10,276,2 "EasyControl Adapter",boiler,211,dhw.gasmeter,gas meter,uint24,kWh,false,sensor.boiler_dhw_gas_meter,sensor.boiler_dhw_gasmeter,6,9,1/10,71,2 -"EasyControl Adapter",boiler,211,nrgheat2,energy heating 2,uint24,kWh,false,sensor.boiler_energy_heating_2,sensor.boiler_nrgheat2,6,0,1/10,277,2 +"EasyControl Adapter",boiler,211,nrgheat2,energy heating 2,uint24,kWh,false,sensor.boiler_energy_heating_2,sensor.boiler_nrgheat2,6,0,1/10,278,2 "EasyControl Adapter",boiler,211,dhw.nrg2,energy 2,uint24,kWh,false,sensor.boiler_dhw_energy_2,sensor.boiler_dhw_nrg2,6,9,1/10,73,2 "EasyControl Adapter",boiler,211,dhw.tapactivated,turn on/off,boolean (>=0<=0), ,true,switch.boiler_dhw_turn_on/off,switch.boiler_dhw_tapactivated,6,9,1,28,1 "EasyControl Adapter",boiler,211,dhw.settemp,set temperature,uint8,C,false,sensor.boiler_dhw_set_temperature,sensor.boiler_dhw_settemp,6,9,1,29,1 @@ -3769,16 +3798,16 @@ device name,device type,product id,shortname,fullname,type [options...] \| (min/ "EasyControl Adapter",boiler,211,dhw.dhwprio,dhw priority,boolean (>=0<=0), ,true,switch.boiler_dhw_dhw_priority,switch.boiler_dhw_dhwprio,6,9,1,66,1 "EasyControl Adapter",boiler,211,dhw.starts,starts,uint24, ,false,sensor.boiler_dhw_starts,sensor.boiler_dhw_starts,6,9,1,67,2 "EasyControl Adapter",boiler,211,dhw.workm,active time,time,minutes,false,sensor.boiler_dhw_active_time,sensor.boiler_dhw_workm,6,9,1,69,2 -"EasyControl Adapter",boiler,211,nompower,nominal Power,uint8 (>=0<=0),kW,true,number.boiler_nominal_Power,number.boiler_nompower,6,0,1,279,1 -"EasyControl Adapter",boiler,211,nrgtotal,total energy,uint24,kWh,false,sensor.boiler_total_energy,sensor.boiler_nrgtotal,6,0,1/100,88,2 -"EasyControl Adapter",boiler,211,nrgheat,energy heating,uint24 (>=0<=10000000),kWh,true,number.boiler_energy_heating,number.boiler_nrgheat,6,0,1/100,90,2 +"EasyControl Adapter",boiler,211,nompower,nominal Power,uint8 (>=0<=0),kW,true,number.boiler_nominal_Power,number.boiler_nompower,6,0,1,280,1 +"EasyControl Adapter",boiler,211,nrgtotal,total energy,uint24,kWh,false,sensor.boiler_total_energy,sensor.boiler_nrgtotal,6,0,1/100,89,2 +"EasyControl Adapter",boiler,211,nrgheat,energy heating,uint24 (>=0<=10000000),kWh,true,number.boiler_energy_heating,number.boiler_nrgheat,6,0,1/100,91,2 "EasyControl Adapter",boiler,211,dhw.nrg,energy,uint24 (>=0<=10000000),kWh,true,number.boiler_dhw_energy,number.boiler_dhw_nrg,6,9,1/100,0,2 -"Greenstar HIU, Logamax kompakt WS170",boiler,219,netflowtemp,heat network flow temp,uint16,C,false,sensor.boiler_heat_network_flow_temp,sensor.boiler_netflowtemp,6,0,1/10,280,1 -"Greenstar HIU, Logamax kompakt WS170",boiler,219,heatvalve,heating valve,uint8,%,false,sensor.boiler_heating_valve,sensor.boiler_heatvalve,6,0,1,281,1 +"Greenstar HIU, Logamax kompakt WS170",boiler,219,netflowtemp,heat network flow temp,uint16,C,false,sensor.boiler_heat_network_flow_temp,sensor.boiler_netflowtemp,6,0,1/10,281,1 +"Greenstar HIU, Logamax kompakt WS170",boiler,219,heatvalve,heating valve,uint8,%,false,sensor.boiler_heating_valve,sensor.boiler_heatvalve,6,0,1,282,1 "Greenstar HIU, Logamax kompakt WS170",boiler,219,dhw.dhwvalve,valve,uint8,%,false,sensor.boiler_dhw_valve,sensor.boiler_dhw_dhwvalve,6,9,1,75,1 -"Greenstar HIU, Logamax kompakt WS170",boiler,219,keepwarmtemp,keep warm temperature,uint8 (>=0<=0),C,true,number.boiler_keep_warm_temperature,number.boiler_keepwarmtemp,6,0,1,282,1 -"Greenstar HIU, Logamax kompakt WS170",boiler,219,setreturntemp,set temp return,uint8 (>=0<=0),C,true,number.boiler_set_temp_return,number.boiler_setreturntemp,6,0,1,283,1 -"Greenstar HIU, Logamax kompakt WS170",boiler,219,heating,heating,boolean, ,false,binary_sensor.boiler_heating,binary_sensor.boiler_heating,6,0,1,284,1 +"Greenstar HIU, Logamax kompakt WS170",boiler,219,keepwarmtemp,keep warm temperature,uint8 (>=0<=0),C,true,number.boiler_keep_warm_temperature,number.boiler_keepwarmtemp,6,0,1,283,1 +"Greenstar HIU, Logamax kompakt WS170",boiler,219,setreturntemp,set temp return,uint8 (>=0<=0),C,true,number.boiler_set_temp_return,number.boiler_setreturntemp,6,0,1,284,1 +"Greenstar HIU, Logamax kompakt WS170",boiler,219,heating,heating,boolean, ,false,binary_sensor.boiler_heating,binary_sensor.boiler_heating,6,0,1,285,1 "Greenstar HIU, Logamax kompakt WS170",boiler,219,reset,reset,cmd [-\|maintenance\|error\|history\|message\|hp error\|burner starts\|factory] (>=0<=0), ,true,sensor.boiler_reset,sensor.boiler_reset,6,0,1,0,1 "Greenstar HIU, Logamax kompakt WS170",boiler,219,chimneysweeper,chimney sweeper,cmd [off\|on] (>=0<=0), ,true,sensor.boiler_chimney_sweeper,sensor.boiler_chimneysweeper,6,0,1,1,1 "Greenstar HIU, Logamax kompakt WS170",boiler,219,heatingoff,force heating off,boolean (>=0<=0), ,true,switch.boiler_force_heating_off,switch.boiler_heatingoff,6,0,1,2,1 @@ -3819,18 +3848,19 @@ device name,device type,product id,shortname,fullname,type [options...] \| (min/ "Greenstar HIU, Logamax kompakt WS170",boiler,219,maintenancedate,next maintenance date,string (>=0<=0), ,true,sensor.boiler_next_maintenance_date,sensor.boiler_maintenancedate,6,0,1,72,6 "Greenstar HIU, Logamax kompakt WS170",boiler,219,emergencyops,emergency operation,boolean (>=0<=0), ,true,switch.boiler_emergency_operation,switch.boiler_emergencyops,6,0,1,78,1 "Greenstar HIU, Logamax kompakt WS170",boiler,219,emergencytemp,emergency temperature,uint8 (>=15<=70),C,true,number.boiler_emergency_temperature,number.boiler_emergencytemp,6,0,1,79,1 -"Greenstar HIU, Logamax kompakt WS170",boiler,219,pc0flow,Flow PC0,int16,l/h,false,sensor.boiler_Flow_PC0,sensor.boiler_pc0flow,6,0,1,80,1 -"Greenstar HIU, Logamax kompakt WS170",boiler,219,pc1flow,Flow PC1,int16,l/h,false,sensor.boiler_Flow_PC1,sensor.boiler_pc1flow,6,0,1,81,1 -"Greenstar HIU, Logamax kompakt WS170",boiler,219,pc1on,PC1,boolean, ,false,binary_sensor.boiler_PC1,binary_sensor.boiler_pc1on,6,0,1,82,1 -"Greenstar HIU, Logamax kompakt WS170",boiler,219,pc1rate,PC1 rate,uint8,%,false,sensor.boiler_PC1_rate,sensor.boiler_pc1rate,6,0,1,83,1 -"Greenstar HIU, Logamax kompakt WS170",boiler,219,pumpkickhour,pump kick hour,uint8 (>=0<=23),hours,true,number.boiler_pump_kick_hour,number.boiler_pumpkickhour,6,0,1,84,1 -"Greenstar HIU, Logamax kompakt WS170",boiler,219,pumpkickday,pump kick day,enum [mo\|tu\|we\|th\|fr\|sa\|su\|all] (>=0<=0), ,true,select.boiler_pump_kick_day,select.boiler_pumpkickday,6,0,1,85,1 -"Greenstar HIU, Logamax kompakt WS170",boiler,219,pumpkickdelay,pump kick delay,uint16 (>=0<=32767),minutes,true,number.boiler_pump_kick_delay,number.boiler_pumpkickdelay,6,0,1,86,1 -"Greenstar HIU, Logamax kompakt WS170",boiler,219,meterheat,meter heating,uint24,kWh,false,sensor.boiler_meter_heating,sensor.boiler_meterheat,6,0,1/10,100,2 +"Greenstar HIU, Logamax kompakt WS170",boiler,219,pc0lpm,Flow PC0,uint16,l/min,false,sensor.boiler_Flow_PC0,sensor.boiler_pc0lpm,6,0,1/10,80,1 +"Greenstar HIU, Logamax kompakt WS170",boiler,219,pc0flow,Flow PC0,uint16,l/h,false,sensor.boiler_Flow_PC0,sensor.boiler_pc0flow,6,0,1,81,1 +"Greenstar HIU, Logamax kompakt WS170",boiler,219,pc1flow,Flow PC1,uint16,l/h,false,sensor.boiler_Flow_PC1,sensor.boiler_pc1flow,6,0,1,82,1 +"Greenstar HIU, Logamax kompakt WS170",boiler,219,pc1on,PC1,boolean, ,false,binary_sensor.boiler_PC1,binary_sensor.boiler_pc1on,6,0,1,83,1 +"Greenstar HIU, Logamax kompakt WS170",boiler,219,pc1rate,PC1 rate,uint8,%,false,sensor.boiler_PC1_rate,sensor.boiler_pc1rate,6,0,1,84,1 +"Greenstar HIU, Logamax kompakt WS170",boiler,219,pumpkickhour,pump kick hour,uint8 (>=0<=23),hours,true,number.boiler_pump_kick_hour,number.boiler_pumpkickhour,6,0,1,85,1 +"Greenstar HIU, Logamax kompakt WS170",boiler,219,pumpkickday,pump kick day,enum [mo\|tu\|we\|th\|fr\|sa\|su\|all] (>=0<=0), ,true,select.boiler_pump_kick_day,select.boiler_pumpkickday,6,0,1,86,1 +"Greenstar HIU, Logamax kompakt WS170",boiler,219,pumpkickdelay,pump kick delay,uint16 (>=0<=32767),minutes,true,number.boiler_pump_kick_delay,number.boiler_pumpkickdelay,6,0,1,87,1 +"Greenstar HIU, Logamax kompakt WS170",boiler,219,meterheat,meter heating,uint24,kWh,false,sensor.boiler_meter_heating,sensor.boiler_meterheat,6,0,1/10,101,2 "Greenstar HIU, Logamax kompakt WS170",boiler,219,dhw.meter,meter,uint24,kWh,false,sensor.boiler_dhw_meter,sensor.boiler_dhw_meter,6,9,1/10,2,2 -"Greenstar HIU, Logamax kompakt WS170",boiler,219,gasmeterheat,gas meter heating,uint24,kWh,false,sensor.boiler_gas_meter_heating,sensor.boiler_gasmeterheat,6,0,1/10,275,2 +"Greenstar HIU, Logamax kompakt WS170",boiler,219,gasmeterheat,gas meter heating,uint24,kWh,false,sensor.boiler_gas_meter_heating,sensor.boiler_gasmeterheat,6,0,1/10,276,2 "Greenstar HIU, Logamax kompakt WS170",boiler,219,dhw.gasmeter,gas meter,uint24,kWh,false,sensor.boiler_dhw_gas_meter,sensor.boiler_dhw_gasmeter,6,9,1/10,71,2 -"Greenstar HIU, Logamax kompakt WS170",boiler,219,nrgheat2,energy heating 2,uint24,kWh,false,sensor.boiler_energy_heating_2,sensor.boiler_nrgheat2,6,0,1/10,277,2 +"Greenstar HIU, Logamax kompakt WS170",boiler,219,nrgheat2,energy heating 2,uint24,kWh,false,sensor.boiler_energy_heating_2,sensor.boiler_nrgheat2,6,0,1/10,278,2 "Greenstar HIU, Logamax kompakt WS170",boiler,219,dhw.nrg2,energy 2,uint24,kWh,false,sensor.boiler_dhw_energy_2,sensor.boiler_dhw_nrg2,6,9,1/10,73,2 "Greenstar HIU, Logamax kompakt WS170",boiler,219,dhw.tapactivated,turn on/off,boolean (>=0<=0), ,true,switch.boiler_dhw_turn_on/off,switch.boiler_dhw_tapactivated,6,9,1,28,1 "Greenstar HIU, Logamax kompakt WS170",boiler,219,dhw.settemp,set temperature,uint8,C,false,sensor.boiler_dhw_set_temperature,sensor.boiler_dhw_settemp,6,9,1,29,1 @@ -3887,28 +3917,28 @@ device name,device type,product id,shortname,fullname,type [options...] \| (min/ "Logamax Plus GB122, Condense 2300, Junkers Cerapur GC2200W",boiler,234,syspress,system pressure,uint8,bar,false,sensor.boiler_system_pressure,sensor.boiler_syspress,6,0,1/10,11,1 "Logamax Plus GB122, Condense 2300, Junkers Cerapur GC2200W",boiler,234,boiltemp,actual boiler temperature,uint16,C,false,sensor.boiler_actual_boiler_temperature,sensor.boiler_boiltemp,6,0,1/10,12,1 "Logamax Plus GB122, Condense 2300, Junkers Cerapur GC2200W",boiler,234,headertemp,low loss header,uint16,C,false,sensor.boiler_low_loss_header,sensor.boiler_headertemp,6,0,1/10,13,1 -"Logamax Plus GB122, Condense 2300, Junkers Cerapur GC2200W",boiler,234,exhausttemp,exhaust temperature,uint16,C,false,sensor.boiler_exhaust_temperature,sensor.boiler_exhausttemp,6,0,1/10,253,1 -"Logamax Plus GB122, Condense 2300, Junkers Cerapur GC2200W",boiler,234,burngas,gas,boolean, ,false,binary_sensor.boiler_gas,binary_sensor.boiler_burngas,6,0,1,254,1 -"Logamax Plus GB122, Condense 2300, Junkers Cerapur GC2200W",boiler,234,burngas2,gas stage 2,boolean, ,false,binary_sensor.boiler_gas_stage_2,binary_sensor.boiler_burngas2,6,0,1,255,1 -"Logamax Plus GB122, Condense 2300, Junkers Cerapur GC2200W",boiler,234,flamecurr,flame current,uint16,µA,false,sensor.boiler_flame_current,sensor.boiler_flamecurr,6,0,1/10,256,1 -"Logamax Plus GB122, Condense 2300, Junkers Cerapur GC2200W",boiler,234,fanwork,fan,boolean, ,false,binary_sensor.boiler_fan,binary_sensor.boiler_fanwork,6,0,1,257,1 -"Logamax Plus GB122, Condense 2300, Junkers Cerapur GC2200W",boiler,234,ignwork,ignition,boolean, ,false,binary_sensor.boiler_ignition,binary_sensor.boiler_ignwork,6,0,1,258,1 -"Logamax Plus GB122, Condense 2300, Junkers Cerapur GC2200W",boiler,234,oilpreheat,oil preheating,boolean, ,false,binary_sensor.boiler_oil_preheating,binary_sensor.boiler_oilpreheat,6,0,1,259,1 -"Logamax Plus GB122, Condense 2300, Junkers Cerapur GC2200W",boiler,234,burnminpower,burner min power,uint8 (>=0<=0),%,true,number.boiler_burner_min_power,number.boiler_burnminpower,6,0,1,260,1 -"Logamax Plus GB122, Condense 2300, Junkers Cerapur GC2200W",boiler,234,burnmaxpower,burner max power,uint8 (>=0<=254),%,true,number.boiler_burner_max_power,number.boiler_burnmaxpower,6,0,1,261,1 -"Logamax Plus GB122, Condense 2300, Junkers Cerapur GC2200W",boiler,234,burnminperiod,burner min period,uint8 (>=0<=120),minutes,true,number.boiler_burner_min_period,number.boiler_burnminperiod,6,0,1,262,1 -"Logamax Plus GB122, Condense 2300, Junkers Cerapur GC2200W",boiler,234,absburnpow,burner current power (absolute),uint8,%,false,sensor.boiler_burner_current_power_(absolute),sensor.boiler_absburnpow,6,0,1,263,1 -"Logamax Plus GB122, Condense 2300, Junkers Cerapur GC2200W",boiler,234,heatblock,Heatblock temperature,uint16,C,false,sensor.boiler_Heatblock_temperature,sensor.boiler_heatblock,6,0,1/10,264,1 -"Logamax Plus GB122, Condense 2300, Junkers Cerapur GC2200W",boiler,234,boilhyston,hysteresis on temperature,int8 (>=-20<=0),C,true,number.boiler_hysteresis_on_temperature,number.boiler_boilhyston,6,0,1,265,1 -"Logamax Plus GB122, Condense 2300, Junkers Cerapur GC2200W",boiler,234,boilhystoff,hysteresis off temperature,int8 (>=0<=20),C,true,number.boiler_hysteresis_off_temperature,number.boiler_boilhystoff,6,0,1,266,1 -"Logamax Plus GB122, Condense 2300, Junkers Cerapur GC2200W",boiler,234,boil2hyston,hysteresis stage 2 on temperature,int8 (>=-20<=0),C,true,number.boiler_hysteresis_stage_2_on_temperature,number.boiler_boil2hyston,6,0,1,267,1 -"Logamax Plus GB122, Condense 2300, Junkers Cerapur GC2200W",boiler,234,boil2hystoff,hysteresis stage 2 off temperature,int8 (>=0<=20),C,true,number.boiler_hysteresis_stage_2_off_temperature,number.boiler_boil2hystoff,6,0,1,268,1 -"Logamax Plus GB122, Condense 2300, Junkers Cerapur GC2200W",boiler,234,curveon,heatingcurve on,boolean (>=0<=0), ,true,switch.boiler_heatingcurve_on,switch.boiler_curveon,6,0,1,269,1 -"Logamax Plus GB122, Condense 2300, Junkers Cerapur GC2200W",boiler,234,curvebase,heatingcurve base,uint8 (>=20<=90),C,true,number.boiler_heatingcurve_base,number.boiler_curvebase,6,0,1,270,1 -"Logamax Plus GB122, Condense 2300, Junkers Cerapur GC2200W",boiler,234,curveend,heatingcurve end,uint8 (>=20<=90),C,true,number.boiler_heatingcurve_end,number.boiler_curveend,6,0,1,271,1 -"Logamax Plus GB122, Condense 2300, Junkers Cerapur GC2200W",boiler,234,summertemp,summer temperature,uint8 (>=0<=45),C,true,number.boiler_summer_temperature,number.boiler_summertemp,6,0,1,272,1 -"Logamax Plus GB122, Condense 2300, Junkers Cerapur GC2200W",boiler,234,nofrostmode,nofrost mode,boolean (>=0<=0), ,true,switch.boiler_nofrost_mode,switch.boiler_nofrostmode,6,0,1,273,1 -"Logamax Plus GB122, Condense 2300, Junkers Cerapur GC2200W",boiler,234,nofrosttemp,nofrost temperature,uint8 (>=0<=10),C,true,number.boiler_nofrost_temperature,number.boiler_nofrosttemp,6,0,1,274,1 +"Logamax Plus GB122, Condense 2300, Junkers Cerapur GC2200W",boiler,234,exhausttemp,exhaust temperature,uint16,C,false,sensor.boiler_exhaust_temperature,sensor.boiler_exhausttemp,6,0,1/10,254,1 +"Logamax Plus GB122, Condense 2300, Junkers Cerapur GC2200W",boiler,234,burngas,gas,boolean, ,false,binary_sensor.boiler_gas,binary_sensor.boiler_burngas,6,0,1,255,1 +"Logamax Plus GB122, Condense 2300, Junkers Cerapur GC2200W",boiler,234,burngas2,gas stage 2,boolean, ,false,binary_sensor.boiler_gas_stage_2,binary_sensor.boiler_burngas2,6,0,1,256,1 +"Logamax Plus GB122, Condense 2300, Junkers Cerapur GC2200W",boiler,234,flamecurr,flame current,uint16,µA,false,sensor.boiler_flame_current,sensor.boiler_flamecurr,6,0,1/10,257,1 +"Logamax Plus GB122, Condense 2300, Junkers Cerapur GC2200W",boiler,234,fanwork,fan,boolean, ,false,binary_sensor.boiler_fan,binary_sensor.boiler_fanwork,6,0,1,258,1 +"Logamax Plus GB122, Condense 2300, Junkers Cerapur GC2200W",boiler,234,ignwork,ignition,boolean, ,false,binary_sensor.boiler_ignition,binary_sensor.boiler_ignwork,6,0,1,259,1 +"Logamax Plus GB122, Condense 2300, Junkers Cerapur GC2200W",boiler,234,oilpreheat,oil preheating,boolean, ,false,binary_sensor.boiler_oil_preheating,binary_sensor.boiler_oilpreheat,6,0,1,260,1 +"Logamax Plus GB122, Condense 2300, Junkers Cerapur GC2200W",boiler,234,burnminpower,burner min power,uint8 (>=0<=0),%,true,number.boiler_burner_min_power,number.boiler_burnminpower,6,0,1,261,1 +"Logamax Plus GB122, Condense 2300, Junkers Cerapur GC2200W",boiler,234,burnmaxpower,burner max power,uint8 (>=0<=254),%,true,number.boiler_burner_max_power,number.boiler_burnmaxpower,6,0,1,262,1 +"Logamax Plus GB122, Condense 2300, Junkers Cerapur GC2200W",boiler,234,burnminperiod,burner min period,uint8 (>=0<=120),minutes,true,number.boiler_burner_min_period,number.boiler_burnminperiod,6,0,1,263,1 +"Logamax Plus GB122, Condense 2300, Junkers Cerapur GC2200W",boiler,234,absburnpow,burner current power (absolute),uint8,%,false,sensor.boiler_burner_current_power_(absolute),sensor.boiler_absburnpow,6,0,1,264,1 +"Logamax Plus GB122, Condense 2300, Junkers Cerapur GC2200W",boiler,234,heatblock,Heatblock temperature,uint16,C,false,sensor.boiler_Heatblock_temperature,sensor.boiler_heatblock,6,0,1/10,265,1 +"Logamax Plus GB122, Condense 2300, Junkers Cerapur GC2200W",boiler,234,boilhyston,hysteresis on temperature,int8 (>=-20<=0),C,true,number.boiler_hysteresis_on_temperature,number.boiler_boilhyston,6,0,1,266,1 +"Logamax Plus GB122, Condense 2300, Junkers Cerapur GC2200W",boiler,234,boilhystoff,hysteresis off temperature,int8 (>=0<=20),C,true,number.boiler_hysteresis_off_temperature,number.boiler_boilhystoff,6,0,1,267,1 +"Logamax Plus GB122, Condense 2300, Junkers Cerapur GC2200W",boiler,234,boil2hyston,hysteresis stage 2 on temperature,int8 (>=-20<=0),C,true,number.boiler_hysteresis_stage_2_on_temperature,number.boiler_boil2hyston,6,0,1,268,1 +"Logamax Plus GB122, Condense 2300, Junkers Cerapur GC2200W",boiler,234,boil2hystoff,hysteresis stage 2 off temperature,int8 (>=0<=20),C,true,number.boiler_hysteresis_stage_2_off_temperature,number.boiler_boil2hystoff,6,0,1,269,1 +"Logamax Plus GB122, Condense 2300, Junkers Cerapur GC2200W",boiler,234,curveon,heatingcurve on,boolean (>=0<=0), ,true,switch.boiler_heatingcurve_on,switch.boiler_curveon,6,0,1,270,1 +"Logamax Plus GB122, Condense 2300, Junkers Cerapur GC2200W",boiler,234,curvebase,heatingcurve base,uint8 (>=20<=90),C,true,number.boiler_heatingcurve_base,number.boiler_curvebase,6,0,1,271,1 +"Logamax Plus GB122, Condense 2300, Junkers Cerapur GC2200W",boiler,234,curveend,heatingcurve end,uint8 (>=20<=90),C,true,number.boiler_heatingcurve_end,number.boiler_curveend,6,0,1,272,1 +"Logamax Plus GB122, Condense 2300, Junkers Cerapur GC2200W",boiler,234,summertemp,summer temperature,uint8 (>=0<=45),C,true,number.boiler_summer_temperature,number.boiler_summertemp,6,0,1,273,1 +"Logamax Plus GB122, Condense 2300, Junkers Cerapur GC2200W",boiler,234,nofrostmode,nofrost mode,boolean (>=0<=0), ,true,switch.boiler_nofrost_mode,switch.boiler_nofrostmode,6,0,1,274,1 +"Logamax Plus GB122, Condense 2300, Junkers Cerapur GC2200W",boiler,234,nofrosttemp,nofrost temperature,uint8 (>=0<=10),C,true,number.boiler_nofrost_temperature,number.boiler_nofrosttemp,6,0,1,275,1 "Logamax Plus GB122, Condense 2300, Junkers Cerapur GC2200W",boiler,234,heatingactivated,heating activated,boolean (>=0<=0), ,true,switch.boiler_heating_activated,switch.boiler_heatingactivated,6,0,1,14,1 "Logamax Plus GB122, Condense 2300, Junkers Cerapur GC2200W",boiler,234,heatingtemp,heating temperature,uint8 (>=0<=90),C,true,number.boiler_heating_temperature,number.boiler_heatingtemp,6,0,1,15,1 "Logamax Plus GB122, Condense 2300, Junkers Cerapur GC2200W",boiler,234,heatingpump,heating pump,boolean, ,false,binary_sensor.boiler_heating_pump,binary_sensor.boiler_heatingpump,6,0,1,16,1 @@ -3935,18 +3965,19 @@ device name,device type,product id,shortname,fullname,type [options...] \| (min/ "Logamax Plus GB122, Condense 2300, Junkers Cerapur GC2200W",boiler,234,maintenancedate,next maintenance date,string (>=0<=0), ,true,sensor.boiler_next_maintenance_date,sensor.boiler_maintenancedate,6,0,1,72,6 "Logamax Plus GB122, Condense 2300, Junkers Cerapur GC2200W",boiler,234,emergencyops,emergency operation,boolean (>=0<=0), ,true,switch.boiler_emergency_operation,switch.boiler_emergencyops,6,0,1,78,1 "Logamax Plus GB122, Condense 2300, Junkers Cerapur GC2200W",boiler,234,emergencytemp,emergency temperature,uint8 (>=15<=70),C,true,number.boiler_emergency_temperature,number.boiler_emergencytemp,6,0,1,79,1 -"Logamax Plus GB122, Condense 2300, Junkers Cerapur GC2200W",boiler,234,pc0flow,Flow PC0,int16,l/h,false,sensor.boiler_Flow_PC0,sensor.boiler_pc0flow,6,0,1,80,1 -"Logamax Plus GB122, Condense 2300, Junkers Cerapur GC2200W",boiler,234,pc1flow,Flow PC1,int16,l/h,false,sensor.boiler_Flow_PC1,sensor.boiler_pc1flow,6,0,1,81,1 -"Logamax Plus GB122, Condense 2300, Junkers Cerapur GC2200W",boiler,234,pc1on,PC1,boolean, ,false,binary_sensor.boiler_PC1,binary_sensor.boiler_pc1on,6,0,1,82,1 -"Logamax Plus GB122, Condense 2300, Junkers Cerapur GC2200W",boiler,234,pc1rate,PC1 rate,uint8,%,false,sensor.boiler_PC1_rate,sensor.boiler_pc1rate,6,0,1,83,1 -"Logamax Plus GB122, Condense 2300, Junkers Cerapur GC2200W",boiler,234,pumpkickhour,pump kick hour,uint8 (>=0<=23),hours,true,number.boiler_pump_kick_hour,number.boiler_pumpkickhour,6,0,1,84,1 -"Logamax Plus GB122, Condense 2300, Junkers Cerapur GC2200W",boiler,234,pumpkickday,pump kick day,enum [mo\|tu\|we\|th\|fr\|sa\|su\|all] (>=0<=0), ,true,select.boiler_pump_kick_day,select.boiler_pumpkickday,6,0,1,85,1 -"Logamax Plus GB122, Condense 2300, Junkers Cerapur GC2200W",boiler,234,pumpkickdelay,pump kick delay,uint16 (>=0<=32767),minutes,true,number.boiler_pump_kick_delay,number.boiler_pumpkickdelay,6,0,1,86,1 -"Logamax Plus GB122, Condense 2300, Junkers Cerapur GC2200W",boiler,234,meterheat,meter heating,uint24,kWh,false,sensor.boiler_meter_heating,sensor.boiler_meterheat,6,0,1/10,100,2 +"Logamax Plus GB122, Condense 2300, Junkers Cerapur GC2200W",boiler,234,pc0lpm,Flow PC0,uint16,l/min,false,sensor.boiler_Flow_PC0,sensor.boiler_pc0lpm,6,0,1/10,80,1 +"Logamax Plus GB122, Condense 2300, Junkers Cerapur GC2200W",boiler,234,pc0flow,Flow PC0,uint16,l/h,false,sensor.boiler_Flow_PC0,sensor.boiler_pc0flow,6,0,1,81,1 +"Logamax Plus GB122, Condense 2300, Junkers Cerapur GC2200W",boiler,234,pc1flow,Flow PC1,uint16,l/h,false,sensor.boiler_Flow_PC1,sensor.boiler_pc1flow,6,0,1,82,1 +"Logamax Plus GB122, Condense 2300, Junkers Cerapur GC2200W",boiler,234,pc1on,PC1,boolean, ,false,binary_sensor.boiler_PC1,binary_sensor.boiler_pc1on,6,0,1,83,1 +"Logamax Plus GB122, Condense 2300, Junkers Cerapur GC2200W",boiler,234,pc1rate,PC1 rate,uint8,%,false,sensor.boiler_PC1_rate,sensor.boiler_pc1rate,6,0,1,84,1 +"Logamax Plus GB122, Condense 2300, Junkers Cerapur GC2200W",boiler,234,pumpkickhour,pump kick hour,uint8 (>=0<=23),hours,true,number.boiler_pump_kick_hour,number.boiler_pumpkickhour,6,0,1,85,1 +"Logamax Plus GB122, Condense 2300, Junkers Cerapur GC2200W",boiler,234,pumpkickday,pump kick day,enum [mo\|tu\|we\|th\|fr\|sa\|su\|all] (>=0<=0), ,true,select.boiler_pump_kick_day,select.boiler_pumpkickday,6,0,1,86,1 +"Logamax Plus GB122, Condense 2300, Junkers Cerapur GC2200W",boiler,234,pumpkickdelay,pump kick delay,uint16 (>=0<=32767),minutes,true,number.boiler_pump_kick_delay,number.boiler_pumpkickdelay,6,0,1,87,1 +"Logamax Plus GB122, Condense 2300, Junkers Cerapur GC2200W",boiler,234,meterheat,meter heating,uint24,kWh,false,sensor.boiler_meter_heating,sensor.boiler_meterheat,6,0,1/10,101,2 "Logamax Plus GB122, Condense 2300, Junkers Cerapur GC2200W",boiler,234,dhw.meter,meter,uint24,kWh,false,sensor.boiler_dhw_meter,sensor.boiler_dhw_meter,6,9,1/10,2,2 -"Logamax Plus GB122, Condense 2300, Junkers Cerapur GC2200W",boiler,234,gasmeterheat,gas meter heating,uint24,kWh,false,sensor.boiler_gas_meter_heating,sensor.boiler_gasmeterheat,6,0,1/10,275,2 +"Logamax Plus GB122, Condense 2300, Junkers Cerapur GC2200W",boiler,234,gasmeterheat,gas meter heating,uint24,kWh,false,sensor.boiler_gas_meter_heating,sensor.boiler_gasmeterheat,6,0,1/10,276,2 "Logamax Plus GB122, Condense 2300, Junkers Cerapur GC2200W",boiler,234,dhw.gasmeter,gas meter,uint24,kWh,false,sensor.boiler_dhw_gas_meter,sensor.boiler_dhw_gasmeter,6,9,1/10,71,2 -"Logamax Plus GB122, Condense 2300, Junkers Cerapur GC2200W",boiler,234,nrgheat2,energy heating 2,uint24,kWh,false,sensor.boiler_energy_heating_2,sensor.boiler_nrgheat2,6,0,1/10,277,2 +"Logamax Plus GB122, Condense 2300, Junkers Cerapur GC2200W",boiler,234,nrgheat2,energy heating 2,uint24,kWh,false,sensor.boiler_energy_heating_2,sensor.boiler_nrgheat2,6,0,1/10,278,2 "Logamax Plus GB122, Condense 2300, Junkers Cerapur GC2200W",boiler,234,dhw.nrg2,energy 2,uint24,kWh,false,sensor.boiler_dhw_energy_2,sensor.boiler_dhw_nrg2,6,9,1/10,73,2 "Logamax Plus GB122, Condense 2300, Junkers Cerapur GC2200W",boiler,234,dhw.tapactivated,turn on/off,boolean (>=0<=0), ,true,switch.boiler_dhw_turn_on/off,switch.boiler_dhw_tapactivated,6,9,1,28,1 "Logamax Plus GB122, Condense 2300, Junkers Cerapur GC2200W",boiler,234,dhw.settemp,set temperature,uint8,C,false,sensor.boiler_dhw_set_temperature,sensor.boiler_dhw_settemp,6,9,1,29,1 @@ -3989,9 +4020,9 @@ device name,device type,product id,shortname,fullname,type [options...] \| (min/ "Logamax Plus GB122, Condense 2300, Junkers Cerapur GC2200W",boiler,234,dhw.dhwprio,dhw priority,boolean (>=0<=0), ,true,switch.boiler_dhw_dhw_priority,switch.boiler_dhw_dhwprio,6,9,1,66,1 "Logamax Plus GB122, Condense 2300, Junkers Cerapur GC2200W",boiler,234,dhw.starts,starts,uint24, ,false,sensor.boiler_dhw_starts,sensor.boiler_dhw_starts,6,9,1,67,2 "Logamax Plus GB122, Condense 2300, Junkers Cerapur GC2200W",boiler,234,dhw.workm,active time,time,minutes,false,sensor.boiler_dhw_active_time,sensor.boiler_dhw_workm,6,9,1,69,2 -"Logamax Plus GB122, Condense 2300, Junkers Cerapur GC2200W",boiler,234,nompower,nominal Power,uint8 (>=0<=0),kW,true,number.boiler_nominal_Power,number.boiler_nompower,6,0,1,279,1 -"Logamax Plus GB122, Condense 2300, Junkers Cerapur GC2200W",boiler,234,nrgtotal,total energy,uint24,kWh,false,sensor.boiler_total_energy,sensor.boiler_nrgtotal,6,0,1/100,88,2 -"Logamax Plus GB122, Condense 2300, Junkers Cerapur GC2200W",boiler,234,nrgheat,energy heating,uint24 (>=0<=10000000),kWh,true,number.boiler_energy_heating,number.boiler_nrgheat,6,0,1/100,90,2 +"Logamax Plus GB122, Condense 2300, Junkers Cerapur GC2200W",boiler,234,nompower,nominal Power,uint8 (>=0<=0),kW,true,number.boiler_nominal_Power,number.boiler_nompower,6,0,1,280,1 +"Logamax Plus GB122, Condense 2300, Junkers Cerapur GC2200W",boiler,234,nrgtotal,total energy,uint24,kWh,false,sensor.boiler_total_energy,sensor.boiler_nrgtotal,6,0,1/100,89,2 +"Logamax Plus GB122, Condense 2300, Junkers Cerapur GC2200W",boiler,234,nrgheat,energy heating,uint24 (>=0<=10000000),kWh,true,number.boiler_energy_heating,number.boiler_nrgheat,6,0,1/100,91,2 "Logamax Plus GB122, Condense 2300, Junkers Cerapur GC2200W",boiler,234,dhw.nrg,energy,uint24 (>=0<=10000000),kWh,true,number.boiler_dhw_energy,number.boiler_dhw_nrg,6,9,1/100,0,2 "Logamatic TC100, Moduline Easy",thermostat,202,errorcode,error code,string, ,false,sensor.thermostat_error_code,sensor.thermostat_errorcode,7,0,1,0,8 "Logamatic TC100, Moduline Easy",thermostat,202,lastcode,last error code,string, ,false,sensor.thermostat_last_error_code,sensor.thermostat_lastcode,7,0,1,8,25 @@ -4744,7 +4775,7 @@ device name,device type,product id,shortname,fullname,type [options...] \| (min/ "Rego 3000, UI800, Logamatic BC400",thermostat,253,pvraiseheat,raise heating with PV,int8 (>=0<=5),K,true,number.thermostat_raise_heating_with_PV,number.thermostat_pvraiseheat,7,0,1,62,1 "Rego 3000, UI800, Logamatic BC400",thermostat,253,pvlowercool,lower cooling with PV,int8 (>=-5<=0),K,true,number.thermostat_lower_cooling_with_PV,number.thermostat_pvlowercool,7,0,1,63,1 "Rego 3000, UI800, Logamatic BC400",thermostat,253,absent,absent,boolean (>=0<=0), ,true,switch.thermostat_absent,switch.thermostat_absent,7,0,1,64,1 -"Rego 3000, UI800, Logamatic BC400",thermostat,253,hpoperatingmode,heatpump operating mode,enum [off\|auto\|heating\|cooling] (>=0<=0), ,true,select.thermostat_heatpump_operating_mode,select.thermostat_hpoperatingmode,7,0,1,89,1 +"Rego 3000, UI800, Logamatic BC400",thermostat,253,hpoperatingmode,heatpump operating mode,enum [summer\|auto\|winter] (>=0<=0), ,true,select.thermostat_heatpump_operating_mode,select.thermostat_hpoperatingmode,7,0,1,89,1 "Rego 3000, UI800, Logamatic BC400",thermostat,253,summertemp,summer temperature,uint8 (>=10<=30),C,true,number.thermostat_summer_temperature,number.thermostat_summertemp,7,0,1,90,1 "Rego 3000, UI800, Logamatic BC400",thermostat,253,instantstart,instant start,uint8 (>=1<=10),K,true,number.thermostat_instant_start,number.thermostat_instantstart,7,0,1,91,1 "Rego 3000, UI800, Logamatic BC400",thermostat,253,coolstart,cooling starttemp,uint8 (>=24<=35),C,true,number.thermostat_cooling_starttemp,number.thermostat_coolstart,7,0,1,92,1 diff --git a/docs/dump_telegrams.csv b/docs/dump_telegrams.csv index ecf2b8589..7a2652abf 100644 --- a/docs/dump_telegrams.csv +++ b/docs/dump_telegrams.csv @@ -13,7 +13,7 @@ telegram_type_id,name,is_fetched 0x19,UBAMonitorSlow, 0x1A,UBASetPoints, 0x1C,UBAMaintenanceStatus, -0x1E,WM10TempMessage, +0x1E,HydrTemp, 0x23,JunkersSetMixer,fetched 0x27,UBASettingsWW,fetched 0x28,WeatherComp,fetched @@ -104,7 +104,7 @@ telegram_type_id,name,is_fetched 0x0292,HPMode,fetched 0x0293,HPMode,fetched 0x0294,HPMode,fetched -0x029B,RC300Curves, +0x029B,RC300Curves,fetched 0x029C,RC300Curves, 0x029D,RC300Curves, 0x029E,RC300Curves, @@ -112,10 +112,10 @@ telegram_type_id,name,is_fetched 0x02A0,RC300Curves, 0x02A1,RC300Curves, 0x02A2,RC300Curves, -0x02A5,CRFMonitor, +0x02A5,RC300Monitor, 0x02A6,RC300Monitor, 0x02A7,RC300Monitor, -0x02A8,CRFMonitor, +0x02A8,RC300Monitor, 0x02A9,RC300Monitor, 0x02AA,RC300Monitor, 0x02AB,RC300Monitor, @@ -172,19 +172,20 @@ telegram_type_id,name,is_fetched 0x0469,HPSet, 0x046A,HPSet, 0x0470,RC300Summer3,fetched -0x0471,RC300Sumr2, -0x0472,RC300Sumr2, -0x0473,RC300Sumr2, -0x0474,RC300Sumr2, -0x0475,RC300Sumr2, -0x0476,RC300Sumr2, -0x0477,RC300Sumr2, -0x0478,RC300Sumr2, +0x0471,RC300Summer2, +0x0472,RC300Summer2, +0x0473,RC300Summer2, +0x0474,RC300Summer2, +0x0475,RC300Summer2, +0x0476,RC300Summer2, +0x0477,RC300Summer2, +0x0478,RC300Summer2, 0x047B,HP2, 0x0484,HPSilentMode,fetched 0x0485,HpCooling,fetched 0x0486,HpInConfig,fetched 0x0488,HPValve,fetched +0x0489,HPpassive, 0x048A,HpPool,fetched 0x048B,HPPumps,fetched 0x048D,HpPower,fetched @@ -199,7 +200,7 @@ telegram_type_id,name,is_fetched 0x04A2,HpInput,fetched 0x04A5,HPFan,fetched 0x04A7,HPPowerLimit,fetched -0x04AA,HPPower2,fetched +0x04AA,HPPower, 0x04AE,HPEnergy,fetched 0x04AF,HPMeters,fetched 0x055C,VentilationSet,fetched diff --git a/src/core/modbus_entity_parameters.hpp b/src/core/modbus_entity_parameters.hpp index c15e78c08..c32d0d947 100644 --- a/src/core/modbus_entity_parameters.hpp +++ b/src/core/modbus_entity_parameters.hpp @@ -56,152 +56,153 @@ const std::initializer_list Modbus::modbus_register_ma REGISTER_MAPPING(dt::BOILER, TAG_TYPE_DEVICE_DATA, FL_(maintenanceDate), 72, 6), // maintenancedate REGISTER_MAPPING(dt::BOILER, TAG_TYPE_DEVICE_DATA, FL_(emergencyOps), 78, 1), // emergencyops REGISTER_MAPPING(dt::BOILER, TAG_TYPE_DEVICE_DATA, FL_(emergencyTemp), 79, 1), // emergencytemp - REGISTER_MAPPING(dt::BOILER, TAG_TYPE_DEVICE_DATA, FL_(pc0Flow), 80, 1), // pc0flow - REGISTER_MAPPING(dt::BOILER, TAG_TYPE_DEVICE_DATA, FL_(pc1Flow), 81, 1), // pc1flow - REGISTER_MAPPING(dt::BOILER, TAG_TYPE_DEVICE_DATA, FL_(pc1On), 82, 1), // pc1on - REGISTER_MAPPING(dt::BOILER, TAG_TYPE_DEVICE_DATA, FL_(pc1Rate), 83, 1), // pc1rate - REGISTER_MAPPING(dt::BOILER, TAG_TYPE_DEVICE_DATA, FL_(pumpKickHour), 84, 1), // pumpkickhour - REGISTER_MAPPING(dt::BOILER, TAG_TYPE_DEVICE_DATA, FL_(pumpKickDay), 85, 1), // pumpkickday - REGISTER_MAPPING(dt::BOILER, TAG_TYPE_DEVICE_DATA, FL_(pumpKickDelay), 86, 1), // pumpkickdelay - REGISTER_MAPPING(dt::BOILER, TAG_TYPE_DEVICE_DATA, FL_(manDefrost), 87, 1), // mandefrost - REGISTER_MAPPING(dt::BOILER, TAG_TYPE_DEVICE_DATA, FL_(nrgTotal), 88, 2), // nrgtotal - REGISTER_MAPPING(dt::BOILER, TAG_TYPE_DEVICE_DATA, FL_(nrgHeat), 90, 2), // nrgheat - REGISTER_MAPPING(dt::BOILER, TAG_TYPE_DEVICE_DATA, FL_(nrgCool), 92, 2), // nrgcool - REGISTER_MAPPING(dt::BOILER, TAG_TYPE_DEVICE_DATA, FL_(meterTotal), 94, 2), // metertotal - REGISTER_MAPPING(dt::BOILER, TAG_TYPE_DEVICE_DATA, FL_(meterComp), 96, 2), // metercomp - REGISTER_MAPPING(dt::BOILER, TAG_TYPE_DEVICE_DATA, FL_(meterEHeat), 98, 2), // metereheat - REGISTER_MAPPING(dt::BOILER, TAG_TYPE_DEVICE_DATA, FL_(meterHeat), 100, 2), // meterheat - REGISTER_MAPPING(dt::BOILER, TAG_TYPE_DEVICE_DATA, FL_(meterCool), 102, 2), // metercool - REGISTER_MAPPING(dt::BOILER, TAG_TYPE_DEVICE_DATA, FL_(upTimeTotal), 104, 2), // uptimetotal - REGISTER_MAPPING(dt::BOILER, TAG_TYPE_DEVICE_DATA, FL_(upTimeControl), 106, 2), // uptimecontrol - REGISTER_MAPPING(dt::BOILER, TAG_TYPE_DEVICE_DATA, FL_(upTimeCompHeating), 108, 2), // uptimecompheating - REGISTER_MAPPING(dt::BOILER, TAG_TYPE_DEVICE_DATA, FL_(upTimeCompCooling), 110, 2), // uptimecompcooling - REGISTER_MAPPING(dt::BOILER, TAG_TYPE_DEVICE_DATA, FL_(upTimeCompPool), 112, 2), // uptimecomppool - REGISTER_MAPPING(dt::BOILER, TAG_TYPE_DEVICE_DATA, FL_(totalCompStarts), 114, 2), // totalcompstarts - REGISTER_MAPPING(dt::BOILER, TAG_TYPE_DEVICE_DATA, FL_(heatingStarts), 116, 2), // heatingstarts - REGISTER_MAPPING(dt::BOILER, TAG_TYPE_DEVICE_DATA, FL_(coolingStarts), 118, 2), // coolingstarts - REGISTER_MAPPING(dt::BOILER, TAG_TYPE_DEVICE_DATA, FL_(poolStarts), 120, 2), // poolstarts - REGISTER_MAPPING(dt::BOILER, TAG_TYPE_DEVICE_DATA, FL_(nrgConsTotal), 122, 2), // nrgconstotal - REGISTER_MAPPING(dt::BOILER, TAG_TYPE_DEVICE_DATA, FL_(nrgConsCompTotal), 124, 2), // nrgconscomptotal - REGISTER_MAPPING(dt::BOILER, TAG_TYPE_DEVICE_DATA, FL_(nrgConsCompHeating), 126, 2), // nrgconscompheating - REGISTER_MAPPING(dt::BOILER, TAG_TYPE_DEVICE_DATA, FL_(nrgConsCompCooling), 128, 2), // nrgconscompcooling - REGISTER_MAPPING(dt::BOILER, TAG_TYPE_DEVICE_DATA, FL_(nrgConsCompPool), 130, 2), // nrgconscomppool - REGISTER_MAPPING(dt::BOILER, TAG_TYPE_DEVICE_DATA, FL_(auxElecHeatNrgConsTotal), 132, 2), // auxelecheatnrgconstotal - REGISTER_MAPPING(dt::BOILER, TAG_TYPE_DEVICE_DATA, FL_(auxElecHeatNrgConsHeating), 134, 2), // auxelecheatnrgconsheating - REGISTER_MAPPING(dt::BOILER, TAG_TYPE_DEVICE_DATA, FL_(auxElecHeatNrgConsPool), 136, 2), // auxelecheatnrgconspool - REGISTER_MAPPING(dt::BOILER, TAG_TYPE_DEVICE_DATA, FL_(nrgSuppTotal), 138, 2), // nrgsupptotal - REGISTER_MAPPING(dt::BOILER, TAG_TYPE_DEVICE_DATA, FL_(nrgSuppHeating), 140, 2), // nrgsuppheating - REGISTER_MAPPING(dt::BOILER, TAG_TYPE_DEVICE_DATA, FL_(nrgSuppCooling), 142, 2), // nrgsuppcooling - REGISTER_MAPPING(dt::BOILER, TAG_TYPE_DEVICE_DATA, FL_(nrgSuppPool), 144, 2), // nrgsupppool - REGISTER_MAPPING(dt::BOILER, TAG_TYPE_DEVICE_DATA, FL_(hpPower), 146, 1), // hppower - REGISTER_MAPPING(dt::BOILER, TAG_TYPE_DEVICE_DATA, FL_(hpMaxPower), 147, 1), // hpmaxpower - REGISTER_MAPPING(dt::BOILER, TAG_TYPE_DEVICE_DATA, FL_(pvMaxComp), 148, 1), // pvmaxcomp - REGISTER_MAPPING(dt::BOILER, TAG_TYPE_DEVICE_DATA, FL_(powerReduction), 149, 1), // powerreduction - REGISTER_MAPPING(dt::BOILER, TAG_TYPE_DEVICE_DATA, FL_(hpSetDiffPress), 150, 1), // hpsetdiffpress - REGISTER_MAPPING(dt::BOILER, TAG_TYPE_DEVICE_DATA, FL_(hpCompOn), 151, 1), // hpcompon - REGISTER_MAPPING(dt::BOILER, TAG_TYPE_DEVICE_DATA, FL_(hpActivity), 152, 1), // hpactivity - REGISTER_MAPPING(dt::BOILER, TAG_TYPE_DEVICE_DATA, FL_(hpBrinePumpSpd), 153, 1), // hpbrinepumpspd - REGISTER_MAPPING(dt::BOILER, TAG_TYPE_DEVICE_DATA, FL_(hpSwitchValve), 154, 1), // hpswitchvalve - REGISTER_MAPPING(dt::BOILER, TAG_TYPE_DEVICE_DATA, FL_(hpCompSpd), 155, 1), // hpcompspd - REGISTER_MAPPING(dt::BOILER, TAG_TYPE_DEVICE_DATA, FL_(hpTargetSpd), 156, 1), // hptargetspd - REGISTER_MAPPING(dt::BOILER, TAG_TYPE_DEVICE_DATA, FL_(hpCircSpd), 157, 1), // hpcircspd - REGISTER_MAPPING(dt::BOILER, TAG_TYPE_DEVICE_DATA, FL_(receiverValveVr0), 158, 1), // recvalve - REGISTER_MAPPING(dt::BOILER, TAG_TYPE_DEVICE_DATA, FL_(expansionValveVr1), 159, 1), // expvalve - REGISTER_MAPPING(dt::BOILER, TAG_TYPE_DEVICE_DATA, FL_(hpBrineIn), 160, 1), // hpbrinein - REGISTER_MAPPING(dt::BOILER, TAG_TYPE_DEVICE_DATA, FL_(hpBrineOut), 161, 1), // hpbrineout - REGISTER_MAPPING(dt::BOILER, TAG_TYPE_DEVICE_DATA, FL_(hpTc0), 162, 1), // hptc0 - REGISTER_MAPPING(dt::BOILER, TAG_TYPE_DEVICE_DATA, FL_(hpTc1), 163, 1), // hptc1 - REGISTER_MAPPING(dt::BOILER, TAG_TYPE_DEVICE_DATA, FL_(hpTc3), 164, 1), // hptc3 - REGISTER_MAPPING(dt::BOILER, TAG_TYPE_DEVICE_DATA, FL_(hpTr1), 165, 1), // hptr1 - REGISTER_MAPPING(dt::BOILER, TAG_TYPE_DEVICE_DATA, FL_(hpTr3), 166, 1), // hptr3 - REGISTER_MAPPING(dt::BOILER, TAG_TYPE_DEVICE_DATA, FL_(hpTr4), 167, 1), // hptr4 - REGISTER_MAPPING(dt::BOILER, TAG_TYPE_DEVICE_DATA, FL_(hpTr5), 168, 1), // hptr5 - REGISTER_MAPPING(dt::BOILER, TAG_TYPE_DEVICE_DATA, FL_(hpTr6), 169, 1), // hptr6 - REGISTER_MAPPING(dt::BOILER, TAG_TYPE_DEVICE_DATA, FL_(hpTr7), 170, 1), // hptr7 - REGISTER_MAPPING(dt::BOILER, TAG_TYPE_DEVICE_DATA, FL_(hpTl2), 171, 1), // hptl2 - REGISTER_MAPPING(dt::BOILER, TAG_TYPE_DEVICE_DATA, FL_(hpPl1), 172, 1), // hppl1 - REGISTER_MAPPING(dt::BOILER, TAG_TYPE_DEVICE_DATA, FL_(hpPh1), 173, 1), // hpph1 - REGISTER_MAPPING(dt::BOILER, TAG_TYPE_DEVICE_DATA, FL_(hpTa4), 174, 1), // hpta4 - REGISTER_MAPPING(dt::BOILER, TAG_TYPE_DEVICE_DATA, FL_(hpTw1), 175, 1), // hptw1 - REGISTER_MAPPING(dt::BOILER, TAG_TYPE_DEVICE_DATA, FL_(poolSetTemp), 176, 1), // poolsettemp - REGISTER_MAPPING(dt::BOILER, TAG_TYPE_DEVICE_DATA, FL_(hp4wayValve), 177, 1), // hp4way - REGISTER_MAPPING(dt::BOILER, TAG_TYPE_DEVICE_DATA, FL_(hpInput1), 178, 1), // hpin1 - REGISTER_MAPPING(dt::BOILER, TAG_TYPE_DEVICE_DATA, FL_(hpIn1Opt), 179, 8), // hpin1opt - REGISTER_MAPPING(dt::BOILER, TAG_TYPE_DEVICE_DATA, FL_(hpInput2), 187, 1), // hpin2 - REGISTER_MAPPING(dt::BOILER, TAG_TYPE_DEVICE_DATA, FL_(hpIn2Opt), 188, 8), // hpin2opt - REGISTER_MAPPING(dt::BOILER, TAG_TYPE_DEVICE_DATA, FL_(hpInput3), 196, 1), // hpin3 - REGISTER_MAPPING(dt::BOILER, TAG_TYPE_DEVICE_DATA, FL_(hpIn3Opt), 197, 8), // hpin3opt - REGISTER_MAPPING(dt::BOILER, TAG_TYPE_DEVICE_DATA, FL_(hpInput4), 205, 1), // hpin4 - REGISTER_MAPPING(dt::BOILER, TAG_TYPE_DEVICE_DATA, FL_(hpIn4Opt), 206, 8), // hpin4opt - REGISTER_MAPPING(dt::BOILER, TAG_TYPE_DEVICE_DATA, FL_(maxHeatComp), 214, 1), // maxheatcomp - REGISTER_MAPPING(dt::BOILER, TAG_TYPE_DEVICE_DATA, FL_(maxHeatHeat), 215, 1), // maxheatheat - REGISTER_MAPPING(dt::BOILER, TAG_TYPE_DEVICE_DATA, FL_(auxHeaterSource), 216, 1), // auxheatersource - REGISTER_MAPPING(dt::BOILER, TAG_TYPE_DEVICE_DATA, FL_(pvCooling), 217, 1), // pvcooling - REGISTER_MAPPING(dt::BOILER, TAG_TYPE_DEVICE_DATA, FL_(auxHeaterOnly), 218, 1), // auxheateronly - REGISTER_MAPPING(dt::BOILER, TAG_TYPE_DEVICE_DATA, FL_(auxHeaterOff), 219, 1), // auxheateroff - REGISTER_MAPPING(dt::BOILER, TAG_TYPE_DEVICE_DATA, FL_(auxHeaterStatus), 220, 1), // auxheaterstatus - REGISTER_MAPPING(dt::BOILER, TAG_TYPE_DEVICE_DATA, FL_(auxHeaterLevel), 221, 1), // auxheaterlevel - REGISTER_MAPPING(dt::BOILER, TAG_TYPE_DEVICE_DATA, FL_(auxHeaterDelay), 222, 1), // auxheaterdelay - REGISTER_MAPPING(dt::BOILER, TAG_TYPE_DEVICE_DATA, FL_(auxMaxLimit), 223, 1), // auxmaxlimit - REGISTER_MAPPING(dt::BOILER, TAG_TYPE_DEVICE_DATA, FL_(auxLimitStart), 224, 1), // auxlimitstart - REGISTER_MAPPING(dt::BOILER, TAG_TYPE_DEVICE_DATA, FL_(auxHeatMode), 225, 1), // auxheatrmode - REGISTER_MAPPING(dt::BOILER, TAG_TYPE_DEVICE_DATA, FL_(hpHystHeat), 226, 1), // hphystheat - REGISTER_MAPPING(dt::BOILER, TAG_TYPE_DEVICE_DATA, FL_(hpHystCool), 227, 1), // hphystcool - REGISTER_MAPPING(dt::BOILER, TAG_TYPE_DEVICE_DATA, FL_(hpHystPool), 228, 1), // hphystpool - REGISTER_MAPPING(dt::BOILER, TAG_TYPE_DEVICE_DATA, FL_(silentMode), 229, 1), // silentmode - REGISTER_MAPPING(dt::BOILER, TAG_TYPE_DEVICE_DATA, FL_(silentFrom), 230, 1), // silentfrom - REGISTER_MAPPING(dt::BOILER, TAG_TYPE_DEVICE_DATA, FL_(silentTo), 231, 1), // silentto - REGISTER_MAPPING(dt::BOILER, TAG_TYPE_DEVICE_DATA, FL_(minTempSilent), 232, 1), // mintempsilent - REGISTER_MAPPING(dt::BOILER, TAG_TYPE_DEVICE_DATA, FL_(tempParMode), 233, 1), // tempparmode - REGISTER_MAPPING(dt::BOILER, TAG_TYPE_DEVICE_DATA, FL_(auxHeatMixValve), 234, 1), // auxheatmix - REGISTER_MAPPING(dt::BOILER, TAG_TYPE_DEVICE_DATA, FL_(tempDiffHeat), 235, 1), // tempdiffheat - REGISTER_MAPPING(dt::BOILER, TAG_TYPE_DEVICE_DATA, FL_(tempDiffCool), 236, 1), // tempdiffcool - REGISTER_MAPPING(dt::BOILER, TAG_TYPE_DEVICE_DATA, FL_(vp_cooling), 237, 1), // vpcooling - REGISTER_MAPPING(dt::BOILER, TAG_TYPE_DEVICE_DATA, FL_(heatCable), 238, 1), // heatcable - REGISTER_MAPPING(dt::BOILER, TAG_TYPE_DEVICE_DATA, FL_(VC0valve), 239, 1), // vc0valve - REGISTER_MAPPING(dt::BOILER, TAG_TYPE_DEVICE_DATA, FL_(primePump), 240, 1), // primepump - REGISTER_MAPPING(dt::BOILER, TAG_TYPE_DEVICE_DATA, FL_(primePumpMod), 241, 1), // primepumpmod - REGISTER_MAPPING(dt::BOILER, TAG_TYPE_DEVICE_DATA, FL_(hp3wayValve), 242, 1), // hp3way - REGISTER_MAPPING(dt::BOILER, TAG_TYPE_DEVICE_DATA, FL_(elHeatStep1), 243, 1), // elheatstep1 - REGISTER_MAPPING(dt::BOILER, TAG_TYPE_DEVICE_DATA, FL_(elHeatStep2), 244, 1), // elheatstep2 - REGISTER_MAPPING(dt::BOILER, TAG_TYPE_DEVICE_DATA, FL_(elHeatStep3), 245, 1), // elheatstep3 - REGISTER_MAPPING(dt::BOILER, TAG_TYPE_DEVICE_DATA, FL_(hpEA0), 246, 1), // hpea0 - REGISTER_MAPPING(dt::BOILER, TAG_TYPE_DEVICE_DATA, FL_(hpPumpMode), 247, 1), // hppumpmode - REGISTER_MAPPING(dt::BOILER, TAG_TYPE_DEVICE_DATA, FL_(hpFan), 248, 1), // fan - REGISTER_MAPPING(dt::BOILER, TAG_TYPE_DEVICE_DATA, FL_(fanSpd), 249, 1), // fanspd - REGISTER_MAPPING(dt::BOILER, TAG_TYPE_DEVICE_DATA, FL_(hpShutdown), 250, 1), // shutdown - REGISTER_MAPPING(dt::BOILER, TAG_TYPE_DEVICE_DATA, FL_(hpCurrPower), 251, 1), // hpcurrpower - REGISTER_MAPPING(dt::BOILER, TAG_TYPE_DEVICE_DATA, FL_(hpPowerLimit), 252, 1), // hppowerlimit - REGISTER_MAPPING(dt::BOILER, TAG_TYPE_DEVICE_DATA, FL_(exhaustTemp), 253, 1), // exhausttemp - REGISTER_MAPPING(dt::BOILER, TAG_TYPE_DEVICE_DATA, FL_(burnGas), 254, 1), // burngas - REGISTER_MAPPING(dt::BOILER, TAG_TYPE_DEVICE_DATA, FL_(burnGas2), 255, 1), // burngas2 - REGISTER_MAPPING(dt::BOILER, TAG_TYPE_DEVICE_DATA, FL_(flameCurr), 256, 1), // flamecurr - REGISTER_MAPPING(dt::BOILER, TAG_TYPE_DEVICE_DATA, FL_(fanWork), 257, 1), // fanwork - REGISTER_MAPPING(dt::BOILER, TAG_TYPE_DEVICE_DATA, FL_(ignWork), 258, 1), // ignwork - REGISTER_MAPPING(dt::BOILER, TAG_TYPE_DEVICE_DATA, FL_(oilPreHeat), 259, 1), // oilpreheat - REGISTER_MAPPING(dt::BOILER, TAG_TYPE_DEVICE_DATA, FL_(burnMinPower), 260, 1), // burnminpower - REGISTER_MAPPING(dt::BOILER, TAG_TYPE_DEVICE_DATA, FL_(burnMaxPower), 261, 1), // burnmaxpower - REGISTER_MAPPING(dt::BOILER, TAG_TYPE_DEVICE_DATA, FL_(burnMinPeriod), 262, 1), // burnminperiod - REGISTER_MAPPING(dt::BOILER, TAG_TYPE_DEVICE_DATA, FL_(absBurnPow), 263, 1), // absburnpow - REGISTER_MAPPING(dt::BOILER, TAG_TYPE_DEVICE_DATA, FL_(heatblock), 264, 1), // heatblock - REGISTER_MAPPING(dt::BOILER, TAG_TYPE_DEVICE_DATA, FL_(boilHystOn), 265, 1), // boilhyston - REGISTER_MAPPING(dt::BOILER, TAG_TYPE_DEVICE_DATA, FL_(boilHystOff), 266, 1), // boilhystoff - REGISTER_MAPPING(dt::BOILER, TAG_TYPE_DEVICE_DATA, FL_(boil2HystOn), 267, 1), // boil2hyston - REGISTER_MAPPING(dt::BOILER, TAG_TYPE_DEVICE_DATA, FL_(boil2HystOff), 268, 1), // boil2hystoff - REGISTER_MAPPING(dt::BOILER, TAG_TYPE_DEVICE_DATA, FL_(curveOn), 269, 1), // curveon - REGISTER_MAPPING(dt::BOILER, TAG_TYPE_DEVICE_DATA, FL_(curveBase), 270, 1), // curvebase - REGISTER_MAPPING(dt::BOILER, TAG_TYPE_DEVICE_DATA, FL_(curveEnd), 271, 1), // curveend - REGISTER_MAPPING(dt::BOILER, TAG_TYPE_DEVICE_DATA, FL_(summertemp), 272, 1), // summertemp - REGISTER_MAPPING(dt::BOILER, TAG_TYPE_DEVICE_DATA, FL_(nofrostmode), 273, 1), // nofrostmode - REGISTER_MAPPING(dt::BOILER, TAG_TYPE_DEVICE_DATA, FL_(nofrosttemp), 274, 1), // nofrosttemp - REGISTER_MAPPING(dt::BOILER, TAG_TYPE_DEVICE_DATA, FL_(gasMeterHeat), 275, 2), // gasmeterheat - REGISTER_MAPPING(dt::BOILER, TAG_TYPE_DEVICE_DATA, FL_(nrgHeat2), 277, 2), // nrgheat2 - REGISTER_MAPPING(dt::BOILER, TAG_TYPE_DEVICE_DATA, FL_(nomPower), 279, 1), // nompower - REGISTER_MAPPING(dt::BOILER, TAG_TYPE_DEVICE_DATA, FL_(netFlowTemp), 280, 1), // netflowtemp - REGISTER_MAPPING(dt::BOILER, TAG_TYPE_DEVICE_DATA, FL_(heatValve), 281, 1), // heatvalve - REGISTER_MAPPING(dt::BOILER, TAG_TYPE_DEVICE_DATA, FL_(keepWarmTemp), 282, 1), // keepwarmtemp - REGISTER_MAPPING(dt::BOILER, TAG_TYPE_DEVICE_DATA, FL_(setReturnTemp), 283, 1), // setreturntemp - REGISTER_MAPPING(dt::BOILER, TAG_TYPE_DEVICE_DATA, FL_(heatingOn), 284, 1), // heating + REGISTER_MAPPING(dt::BOILER, TAG_TYPE_DEVICE_DATA, FL_(pc0lpm), 80, 1), // pc0lpm + REGISTER_MAPPING(dt::BOILER, TAG_TYPE_DEVICE_DATA, FL_(pc0Flow), 81, 1), // pc0flow + REGISTER_MAPPING(dt::BOILER, TAG_TYPE_DEVICE_DATA, FL_(pc1Flow), 82, 1), // pc1flow + REGISTER_MAPPING(dt::BOILER, TAG_TYPE_DEVICE_DATA, FL_(pc1On), 83, 1), // pc1on + REGISTER_MAPPING(dt::BOILER, TAG_TYPE_DEVICE_DATA, FL_(pc1Rate), 84, 1), // pc1rate + REGISTER_MAPPING(dt::BOILER, TAG_TYPE_DEVICE_DATA, FL_(pumpKickHour), 85, 1), // pumpkickhour + REGISTER_MAPPING(dt::BOILER, TAG_TYPE_DEVICE_DATA, FL_(pumpKickDay), 86, 1), // pumpkickday + REGISTER_MAPPING(dt::BOILER, TAG_TYPE_DEVICE_DATA, FL_(pumpKickDelay), 87, 1), // pumpkickdelay + REGISTER_MAPPING(dt::BOILER, TAG_TYPE_DEVICE_DATA, FL_(manDefrost), 88, 1), // mandefrost + REGISTER_MAPPING(dt::BOILER, TAG_TYPE_DEVICE_DATA, FL_(nrgTotal), 89, 2), // nrgtotal + REGISTER_MAPPING(dt::BOILER, TAG_TYPE_DEVICE_DATA, FL_(nrgHeat), 91, 2), // nrgheat + REGISTER_MAPPING(dt::BOILER, TAG_TYPE_DEVICE_DATA, FL_(nrgCool), 93, 2), // nrgcool + REGISTER_MAPPING(dt::BOILER, TAG_TYPE_DEVICE_DATA, FL_(meterTotal), 95, 2), // metertotal + REGISTER_MAPPING(dt::BOILER, TAG_TYPE_DEVICE_DATA, FL_(meterComp), 97, 2), // metercomp + REGISTER_MAPPING(dt::BOILER, TAG_TYPE_DEVICE_DATA, FL_(meterEHeat), 99, 2), // metereheat + REGISTER_MAPPING(dt::BOILER, TAG_TYPE_DEVICE_DATA, FL_(meterHeat), 101, 2), // meterheat + REGISTER_MAPPING(dt::BOILER, TAG_TYPE_DEVICE_DATA, FL_(meterCool), 103, 2), // metercool + REGISTER_MAPPING(dt::BOILER, TAG_TYPE_DEVICE_DATA, FL_(upTimeTotal), 105, 2), // uptimetotal + REGISTER_MAPPING(dt::BOILER, TAG_TYPE_DEVICE_DATA, FL_(upTimeControl), 107, 2), // uptimecontrol + REGISTER_MAPPING(dt::BOILER, TAG_TYPE_DEVICE_DATA, FL_(upTimeCompHeating), 109, 2), // uptimecompheating + REGISTER_MAPPING(dt::BOILER, TAG_TYPE_DEVICE_DATA, FL_(upTimeCompCooling), 111, 2), // uptimecompcooling + REGISTER_MAPPING(dt::BOILER, TAG_TYPE_DEVICE_DATA, FL_(upTimeCompPool), 113, 2), // uptimecomppool + REGISTER_MAPPING(dt::BOILER, TAG_TYPE_DEVICE_DATA, FL_(totalCompStarts), 115, 2), // totalcompstarts + REGISTER_MAPPING(dt::BOILER, TAG_TYPE_DEVICE_DATA, FL_(heatingStarts), 117, 2), // heatingstarts + REGISTER_MAPPING(dt::BOILER, TAG_TYPE_DEVICE_DATA, FL_(coolingStarts), 119, 2), // coolingstarts + REGISTER_MAPPING(dt::BOILER, TAG_TYPE_DEVICE_DATA, FL_(poolStarts), 121, 2), // poolstarts + REGISTER_MAPPING(dt::BOILER, TAG_TYPE_DEVICE_DATA, FL_(nrgConsTotal), 123, 2), // nrgconstotal + REGISTER_MAPPING(dt::BOILER, TAG_TYPE_DEVICE_DATA, FL_(nrgConsCompTotal), 125, 2), // nrgconscomptotal + REGISTER_MAPPING(dt::BOILER, TAG_TYPE_DEVICE_DATA, FL_(nrgConsCompHeating), 127, 2), // nrgconscompheating + REGISTER_MAPPING(dt::BOILER, TAG_TYPE_DEVICE_DATA, FL_(nrgConsCompCooling), 129, 2), // nrgconscompcooling + REGISTER_MAPPING(dt::BOILER, TAG_TYPE_DEVICE_DATA, FL_(nrgConsCompPool), 131, 2), // nrgconscomppool + REGISTER_MAPPING(dt::BOILER, TAG_TYPE_DEVICE_DATA, FL_(auxElecHeatNrgConsTotal), 133, 2), // auxelecheatnrgconstotal + REGISTER_MAPPING(dt::BOILER, TAG_TYPE_DEVICE_DATA, FL_(auxElecHeatNrgConsHeating), 135, 2), // auxelecheatnrgconsheating + REGISTER_MAPPING(dt::BOILER, TAG_TYPE_DEVICE_DATA, FL_(auxElecHeatNrgConsPool), 137, 2), // auxelecheatnrgconspool + REGISTER_MAPPING(dt::BOILER, TAG_TYPE_DEVICE_DATA, FL_(nrgSuppTotal), 139, 2), // nrgsupptotal + REGISTER_MAPPING(dt::BOILER, TAG_TYPE_DEVICE_DATA, FL_(nrgSuppHeating), 141, 2), // nrgsuppheating + REGISTER_MAPPING(dt::BOILER, TAG_TYPE_DEVICE_DATA, FL_(nrgSuppCooling), 143, 2), // nrgsuppcooling + REGISTER_MAPPING(dt::BOILER, TAG_TYPE_DEVICE_DATA, FL_(nrgSuppPool), 145, 2), // nrgsupppool + REGISTER_MAPPING(dt::BOILER, TAG_TYPE_DEVICE_DATA, FL_(hpPower), 147, 1), // hppower + REGISTER_MAPPING(dt::BOILER, TAG_TYPE_DEVICE_DATA, FL_(hpMaxPower), 148, 1), // hpmaxpower + REGISTER_MAPPING(dt::BOILER, TAG_TYPE_DEVICE_DATA, FL_(pvMaxComp), 149, 1), // pvmaxcomp + REGISTER_MAPPING(dt::BOILER, TAG_TYPE_DEVICE_DATA, FL_(powerReduction), 150, 1), // powerreduction + REGISTER_MAPPING(dt::BOILER, TAG_TYPE_DEVICE_DATA, FL_(hpSetDiffPress), 151, 1), // hpsetdiffpress + REGISTER_MAPPING(dt::BOILER, TAG_TYPE_DEVICE_DATA, FL_(hpCompOn), 152, 1), // hpcompon + REGISTER_MAPPING(dt::BOILER, TAG_TYPE_DEVICE_DATA, FL_(hpActivity), 153, 1), // hpactivity + REGISTER_MAPPING(dt::BOILER, TAG_TYPE_DEVICE_DATA, FL_(hpBrinePumpSpd), 154, 1), // hpbrinepumpspd + REGISTER_MAPPING(dt::BOILER, TAG_TYPE_DEVICE_DATA, FL_(hpSwitchValve), 155, 1), // hpswitchvalve + REGISTER_MAPPING(dt::BOILER, TAG_TYPE_DEVICE_DATA, FL_(hpCompSpd), 156, 1), // hpcompspd + REGISTER_MAPPING(dt::BOILER, TAG_TYPE_DEVICE_DATA, FL_(hpTargetSpd), 157, 1), // hptargetspd + REGISTER_MAPPING(dt::BOILER, TAG_TYPE_DEVICE_DATA, FL_(hpCircSpd), 158, 1), // hpcircspd + REGISTER_MAPPING(dt::BOILER, TAG_TYPE_DEVICE_DATA, FL_(receiverValveVr0), 159, 1), // recvalve + REGISTER_MAPPING(dt::BOILER, TAG_TYPE_DEVICE_DATA, FL_(expansionValveVr1), 160, 1), // expvalve + REGISTER_MAPPING(dt::BOILER, TAG_TYPE_DEVICE_DATA, FL_(hpBrineIn), 161, 1), // hpbrinein + REGISTER_MAPPING(dt::BOILER, TAG_TYPE_DEVICE_DATA, FL_(hpBrineOut), 162, 1), // hpbrineout + REGISTER_MAPPING(dt::BOILER, TAG_TYPE_DEVICE_DATA, FL_(hpTc0), 163, 1), // hptc0 + REGISTER_MAPPING(dt::BOILER, TAG_TYPE_DEVICE_DATA, FL_(hpTc1), 164, 1), // hptc1 + REGISTER_MAPPING(dt::BOILER, TAG_TYPE_DEVICE_DATA, FL_(hpTc3), 165, 1), // hptc3 + REGISTER_MAPPING(dt::BOILER, TAG_TYPE_DEVICE_DATA, FL_(hpTr1), 166, 1), // hptr1 + REGISTER_MAPPING(dt::BOILER, TAG_TYPE_DEVICE_DATA, FL_(hpTr3), 167, 1), // hptr3 + REGISTER_MAPPING(dt::BOILER, TAG_TYPE_DEVICE_DATA, FL_(hpTr4), 168, 1), // hptr4 + REGISTER_MAPPING(dt::BOILER, TAG_TYPE_DEVICE_DATA, FL_(hpTr5), 169, 1), // hptr5 + REGISTER_MAPPING(dt::BOILER, TAG_TYPE_DEVICE_DATA, FL_(hpTr6), 170, 1), // hptr6 + REGISTER_MAPPING(dt::BOILER, TAG_TYPE_DEVICE_DATA, FL_(hpTr7), 171, 1), // hptr7 + REGISTER_MAPPING(dt::BOILER, TAG_TYPE_DEVICE_DATA, FL_(hpTl2), 172, 1), // hptl2 + REGISTER_MAPPING(dt::BOILER, TAG_TYPE_DEVICE_DATA, FL_(hpPl1), 173, 1), // hppl1 + REGISTER_MAPPING(dt::BOILER, TAG_TYPE_DEVICE_DATA, FL_(hpPh1), 174, 1), // hpph1 + REGISTER_MAPPING(dt::BOILER, TAG_TYPE_DEVICE_DATA, FL_(hpTa4), 175, 1), // hpta4 + REGISTER_MAPPING(dt::BOILER, TAG_TYPE_DEVICE_DATA, FL_(hpTw1), 176, 1), // hptw1 + REGISTER_MAPPING(dt::BOILER, TAG_TYPE_DEVICE_DATA, FL_(poolSetTemp), 177, 1), // poolsettemp + REGISTER_MAPPING(dt::BOILER, TAG_TYPE_DEVICE_DATA, FL_(hp4wayValve), 178, 1), // hp4way + REGISTER_MAPPING(dt::BOILER, TAG_TYPE_DEVICE_DATA, FL_(hpInput1), 179, 1), // hpin1 + REGISTER_MAPPING(dt::BOILER, TAG_TYPE_DEVICE_DATA, FL_(hpIn1Opt), 180, 8), // hpin1opt + REGISTER_MAPPING(dt::BOILER, TAG_TYPE_DEVICE_DATA, FL_(hpInput2), 188, 1), // hpin2 + REGISTER_MAPPING(dt::BOILER, TAG_TYPE_DEVICE_DATA, FL_(hpIn2Opt), 189, 8), // hpin2opt + REGISTER_MAPPING(dt::BOILER, TAG_TYPE_DEVICE_DATA, FL_(hpInput3), 197, 1), // hpin3 + REGISTER_MAPPING(dt::BOILER, TAG_TYPE_DEVICE_DATA, FL_(hpIn3Opt), 198, 8), // hpin3opt + REGISTER_MAPPING(dt::BOILER, TAG_TYPE_DEVICE_DATA, FL_(hpInput4), 206, 1), // hpin4 + REGISTER_MAPPING(dt::BOILER, TAG_TYPE_DEVICE_DATA, FL_(hpIn4Opt), 207, 8), // hpin4opt + REGISTER_MAPPING(dt::BOILER, TAG_TYPE_DEVICE_DATA, FL_(maxHeatComp), 215, 1), // maxheatcomp + REGISTER_MAPPING(dt::BOILER, TAG_TYPE_DEVICE_DATA, FL_(maxHeatHeat), 216, 1), // maxheatheat + REGISTER_MAPPING(dt::BOILER, TAG_TYPE_DEVICE_DATA, FL_(auxHeaterSource), 217, 1), // auxheatersource + REGISTER_MAPPING(dt::BOILER, TAG_TYPE_DEVICE_DATA, FL_(pvCooling), 218, 1), // pvcooling + REGISTER_MAPPING(dt::BOILER, TAG_TYPE_DEVICE_DATA, FL_(auxHeaterOnly), 219, 1), // auxheateronly + REGISTER_MAPPING(dt::BOILER, TAG_TYPE_DEVICE_DATA, FL_(auxHeaterOff), 220, 1), // auxheateroff + REGISTER_MAPPING(dt::BOILER, TAG_TYPE_DEVICE_DATA, FL_(auxHeaterStatus), 221, 1), // auxheaterstatus + REGISTER_MAPPING(dt::BOILER, TAG_TYPE_DEVICE_DATA, FL_(auxHeaterLevel), 222, 1), // auxheaterlevel + REGISTER_MAPPING(dt::BOILER, TAG_TYPE_DEVICE_DATA, FL_(auxHeaterDelay), 223, 1), // auxheaterdelay + REGISTER_MAPPING(dt::BOILER, TAG_TYPE_DEVICE_DATA, FL_(auxMaxLimit), 224, 1), // auxmaxlimit + REGISTER_MAPPING(dt::BOILER, TAG_TYPE_DEVICE_DATA, FL_(auxLimitStart), 225, 1), // auxlimitstart + REGISTER_MAPPING(dt::BOILER, TAG_TYPE_DEVICE_DATA, FL_(auxHeatMode), 226, 1), // auxheatrmode + REGISTER_MAPPING(dt::BOILER, TAG_TYPE_DEVICE_DATA, FL_(hpHystHeat), 227, 1), // hphystheat + REGISTER_MAPPING(dt::BOILER, TAG_TYPE_DEVICE_DATA, FL_(hpHystCool), 228, 1), // hphystcool + REGISTER_MAPPING(dt::BOILER, TAG_TYPE_DEVICE_DATA, FL_(hpHystPool), 229, 1), // hphystpool + REGISTER_MAPPING(dt::BOILER, TAG_TYPE_DEVICE_DATA, FL_(silentMode), 230, 1), // silentmode + REGISTER_MAPPING(dt::BOILER, TAG_TYPE_DEVICE_DATA, FL_(silentFrom), 231, 1), // silentfrom + REGISTER_MAPPING(dt::BOILER, TAG_TYPE_DEVICE_DATA, FL_(silentTo), 232, 1), // silentto + REGISTER_MAPPING(dt::BOILER, TAG_TYPE_DEVICE_DATA, FL_(minTempSilent), 233, 1), // mintempsilent + REGISTER_MAPPING(dt::BOILER, TAG_TYPE_DEVICE_DATA, FL_(tempParMode), 234, 1), // tempparmode + REGISTER_MAPPING(dt::BOILER, TAG_TYPE_DEVICE_DATA, FL_(auxHeatMixValve), 235, 1), // auxheatmix + REGISTER_MAPPING(dt::BOILER, TAG_TYPE_DEVICE_DATA, FL_(tempDiffHeat), 236, 1), // tempdiffheat + REGISTER_MAPPING(dt::BOILER, TAG_TYPE_DEVICE_DATA, FL_(tempDiffCool), 237, 1), // tempdiffcool + REGISTER_MAPPING(dt::BOILER, TAG_TYPE_DEVICE_DATA, FL_(vp_cooling), 238, 1), // vpcooling + REGISTER_MAPPING(dt::BOILER, TAG_TYPE_DEVICE_DATA, FL_(heatCable), 239, 1), // heatcable + REGISTER_MAPPING(dt::BOILER, TAG_TYPE_DEVICE_DATA, FL_(VC0valve), 240, 1), // vc0valve + REGISTER_MAPPING(dt::BOILER, TAG_TYPE_DEVICE_DATA, FL_(primePump), 241, 1), // primepump + REGISTER_MAPPING(dt::BOILER, TAG_TYPE_DEVICE_DATA, FL_(primePumpMod), 242, 1), // primepumpmod + REGISTER_MAPPING(dt::BOILER, TAG_TYPE_DEVICE_DATA, FL_(hp3wayValve), 243, 1), // hp3way + REGISTER_MAPPING(dt::BOILER, TAG_TYPE_DEVICE_DATA, FL_(elHeatStep1), 244, 1), // elheatstep1 + REGISTER_MAPPING(dt::BOILER, TAG_TYPE_DEVICE_DATA, FL_(elHeatStep2), 245, 1), // elheatstep2 + REGISTER_MAPPING(dt::BOILER, TAG_TYPE_DEVICE_DATA, FL_(elHeatStep3), 246, 1), // elheatstep3 + REGISTER_MAPPING(dt::BOILER, TAG_TYPE_DEVICE_DATA, FL_(hpEA0), 247, 1), // hpea0 + REGISTER_MAPPING(dt::BOILER, TAG_TYPE_DEVICE_DATA, FL_(hpPumpMode), 248, 1), // hppumpmode + REGISTER_MAPPING(dt::BOILER, TAG_TYPE_DEVICE_DATA, FL_(hpFan), 249, 1), // fan + REGISTER_MAPPING(dt::BOILER, TAG_TYPE_DEVICE_DATA, FL_(fanSpd), 250, 1), // fanspd + REGISTER_MAPPING(dt::BOILER, TAG_TYPE_DEVICE_DATA, FL_(hpShutdown), 251, 1), // shutdown + REGISTER_MAPPING(dt::BOILER, TAG_TYPE_DEVICE_DATA, FL_(hpCurrPower), 252, 1), // hpcurrpower + REGISTER_MAPPING(dt::BOILER, TAG_TYPE_DEVICE_DATA, FL_(hpPowerLimit), 253, 1), // hppowerlimit + REGISTER_MAPPING(dt::BOILER, TAG_TYPE_DEVICE_DATA, FL_(exhaustTemp), 254, 1), // exhausttemp + REGISTER_MAPPING(dt::BOILER, TAG_TYPE_DEVICE_DATA, FL_(burnGas), 255, 1), // burngas + REGISTER_MAPPING(dt::BOILER, TAG_TYPE_DEVICE_DATA, FL_(burnGas2), 256, 1), // burngas2 + REGISTER_MAPPING(dt::BOILER, TAG_TYPE_DEVICE_DATA, FL_(flameCurr), 257, 1), // flamecurr + REGISTER_MAPPING(dt::BOILER, TAG_TYPE_DEVICE_DATA, FL_(fanWork), 258, 1), // fanwork + REGISTER_MAPPING(dt::BOILER, TAG_TYPE_DEVICE_DATA, FL_(ignWork), 259, 1), // ignwork + REGISTER_MAPPING(dt::BOILER, TAG_TYPE_DEVICE_DATA, FL_(oilPreHeat), 260, 1), // oilpreheat + REGISTER_MAPPING(dt::BOILER, TAG_TYPE_DEVICE_DATA, FL_(burnMinPower), 261, 1), // burnminpower + REGISTER_MAPPING(dt::BOILER, TAG_TYPE_DEVICE_DATA, FL_(burnMaxPower), 262, 1), // burnmaxpower + REGISTER_MAPPING(dt::BOILER, TAG_TYPE_DEVICE_DATA, FL_(burnMinPeriod), 263, 1), // burnminperiod + REGISTER_MAPPING(dt::BOILER, TAG_TYPE_DEVICE_DATA, FL_(absBurnPow), 264, 1), // absburnpow + REGISTER_MAPPING(dt::BOILER, TAG_TYPE_DEVICE_DATA, FL_(heatblock), 265, 1), // heatblock + REGISTER_MAPPING(dt::BOILER, TAG_TYPE_DEVICE_DATA, FL_(boilHystOn), 266, 1), // boilhyston + REGISTER_MAPPING(dt::BOILER, TAG_TYPE_DEVICE_DATA, FL_(boilHystOff), 267, 1), // boilhystoff + REGISTER_MAPPING(dt::BOILER, TAG_TYPE_DEVICE_DATA, FL_(boil2HystOn), 268, 1), // boil2hyston + REGISTER_MAPPING(dt::BOILER, TAG_TYPE_DEVICE_DATA, FL_(boil2HystOff), 269, 1), // boil2hystoff + REGISTER_MAPPING(dt::BOILER, TAG_TYPE_DEVICE_DATA, FL_(curveOn), 270, 1), // curveon + REGISTER_MAPPING(dt::BOILER, TAG_TYPE_DEVICE_DATA, FL_(curveBase), 271, 1), // curvebase + REGISTER_MAPPING(dt::BOILER, TAG_TYPE_DEVICE_DATA, FL_(curveEnd), 272, 1), // curveend + REGISTER_MAPPING(dt::BOILER, TAG_TYPE_DEVICE_DATA, FL_(summertemp), 273, 1), // summertemp + REGISTER_MAPPING(dt::BOILER, TAG_TYPE_DEVICE_DATA, FL_(nofrostmode), 274, 1), // nofrostmode + REGISTER_MAPPING(dt::BOILER, TAG_TYPE_DEVICE_DATA, FL_(nofrosttemp), 275, 1), // nofrosttemp + REGISTER_MAPPING(dt::BOILER, TAG_TYPE_DEVICE_DATA, FL_(gasMeterHeat), 276, 2), // gasmeterheat + REGISTER_MAPPING(dt::BOILER, TAG_TYPE_DEVICE_DATA, FL_(nrgHeat2), 278, 2), // nrgheat2 + REGISTER_MAPPING(dt::BOILER, TAG_TYPE_DEVICE_DATA, FL_(nomPower), 280, 1), // nompower + REGISTER_MAPPING(dt::BOILER, TAG_TYPE_DEVICE_DATA, FL_(netFlowTemp), 281, 1), // netflowtemp + REGISTER_MAPPING(dt::BOILER, TAG_TYPE_DEVICE_DATA, FL_(heatValve), 282, 1), // heatvalve + REGISTER_MAPPING(dt::BOILER, TAG_TYPE_DEVICE_DATA, FL_(keepWarmTemp), 283, 1), // keepwarmtemp + REGISTER_MAPPING(dt::BOILER, TAG_TYPE_DEVICE_DATA, FL_(setReturnTemp), 284, 1), // setreturntemp + REGISTER_MAPPING(dt::BOILER, TAG_TYPE_DEVICE_DATA, FL_(heatingOn), 285, 1), // heating REGISTER_MAPPING(dt::BOILER, TAG_TYPE_DHW, FL_(nrgWw), 0, 2), // nrg REGISTER_MAPPING(dt::BOILER, TAG_TYPE_DHW, FL_(meterWw), 2, 2), // meter REGISTER_MAPPING(dt::BOILER, TAG_TYPE_DHW, FL_(upTimeCompWw), 4, 2), // uptimecomp