factor for charge duration

This commit is contained in:
MichaelDvP
2021-09-20 08:49:57 +02:00
parent 11590061a3
commit 5686094151
4 changed files with 62 additions and 32 deletions

View File

@@ -1383,11 +1383,12 @@ bool Thermostat::set_wwcharge(const char * value, const int8_t id) {
// Set ww charge duration in steps of 15 min, ems+
bool Thermostat::set_wwchargeduration(const char * value, const int8_t id) {
uint8_t t = 0xFF;
if (!Helpers::value2enum(value, t, FL_(enum_wwChargeDuration))) {
int t = 0xFF;
if (!Helpers::value2number(value, t)) {
LOG_WARNING(F("Set warm water charge duration: Invalid value"));
return false;
}
t = (t + 8) / 15;
LOG_INFO(F("Setting warm water charge duration to %d min"), t * 15);
write_command(0x2F5, 10, t, 0x02F5);
return true;
@@ -2420,10 +2421,10 @@ void Thermostat::register_device_values() {
TAG_THERMOSTAT_DATA, &wwCircMode_, DeviceValueType::ENUM, FL_(enum_wwCircMode), FL_(wwCircMode), DeviceValueUOM::LIST, MAKE_CF_CB(set_wwcircmode));
register_device_value(TAG_THERMOSTAT_DATA,
&wwChargeDuration_,
DeviceValueType::ENUM,
FL_(enum_wwChargeDuration),
DeviceValueType::UINT,
FL_(mul15),
FL_(wwChargeDuration),
DeviceValueUOM::LIST,
DeviceValueUOM::MINUTES,
MAKE_CF_CB(set_wwchargeduration));
register_device_value(TAG_THERMOSTAT_DATA, &wwCharge_, DeviceValueType::BOOL, nullptr, FL_(wwCharge), DeviceValueUOM::BOOLEAN, MAKE_CF_CB(set_wwcharge));