mirror of
https://github.com/emsesp/EMS-ESP32.git
synced 2025-12-08 00:39:50 +03:00
optimized Type detection on incoming telegrams
This commit is contained in:
@@ -32,7 +32,7 @@ DS18 ds18;
|
||||
#define myDebug_P(...) myESP.myDebug_P(__VA_ARGS__)
|
||||
|
||||
// set to value >0 if the ESP is overheating or there are timing issues. Recommend a value of 1.
|
||||
#define EMSESP_DELAY 0 // initially set to 0 for no delay
|
||||
#define EMSESP_DELAY 1 // initially set to 0 for no delay
|
||||
|
||||
// timers, all values are in seconds
|
||||
#define DEFAULT_PUBLISHWAIT 120 // every 2 minutes publish MQTT values, including Dallas sensors
|
||||
@@ -1204,7 +1204,7 @@ void do_ledcheck() {
|
||||
// Thermostat scan
|
||||
void do_scanThermostat() {
|
||||
if ((ems_getBusConnected()) && (!myESP.getUseSerial())) {
|
||||
myDebug("> Scanning thermostat message type #0x%02X..", scanThermostat_count);
|
||||
myDebug("> Scanning thermostat message type #0x%02X...", scanThermostat_count);
|
||||
ems_doReadCommand(scanThermostat_count, EMS_Thermostat.type_id);
|
||||
scanThermostat_count++;
|
||||
}
|
||||
@@ -1221,7 +1221,7 @@ void do_systemCheck() {
|
||||
// only if we have a EMS connection
|
||||
void do_regularUpdates() {
|
||||
if ((ems_getBusConnected()) && (!myESP.getUseSerial())) {
|
||||
myDebugLog("Calling scheduled data refresh from EMS devices..");
|
||||
myDebugLog("Calling scheduled data refresh from EMS devices...");
|
||||
ems_getThermostatValues();
|
||||
ems_getBoilerValues();
|
||||
ems_getOtherValues();
|
||||
|
||||
16
src/ems.cpp
16
src/ems.cpp
@@ -759,25 +759,25 @@ void _ems_processTelegram(_EMS_RxTelegram * EMS_RxTelegram) {
|
||||
}
|
||||
|
||||
// see if we recognize the type first by scanning our known EMS types list
|
||||
// trying to match the type ID
|
||||
bool commonType = false;
|
||||
bool typeFound = false;
|
||||
bool forUs = false;
|
||||
int i = 0;
|
||||
uint8_t i = 0;
|
||||
|
||||
while (i < _EMS_Types_max) {
|
||||
if (EMS_Types[i].type == type) {
|
||||
// is it common type for everyone?
|
||||
// is it for us? So the src must match with either the boiler, thermostat or other devices
|
||||
if ((EMS_Types[i].model_id == EMS_MODEL_ALL)
|
||||
|| ((src == EMS_Boiler.type_id) || (src == EMS_Thermostat.type_id) || (src == EMS_ID_SM10))) {
|
||||
typeFound = true;
|
||||
commonType = (EMS_Types[i].model_id == EMS_MODEL_ALL); // is it common type for everyone?
|
||||
forUs = (src == EMS_Boiler.type_id) || (src == EMS_Thermostat.type_id); // is it for us? So the src must match
|
||||
break;
|
||||
}
|
||||
}
|
||||
i++;
|
||||
}
|
||||
|
||||
// if it's a common type (across ems devices) or something specifically for us process it.
|
||||
// dest will be EMS_ID_NONE and offset 0x00 for a broadcast message
|
||||
if (typeFound && (commonType || forUs)) {
|
||||
if (typeFound) {
|
||||
if ((EMS_Types[i].processType_cb) != (void *)NULL) {
|
||||
// print non-verbose message
|
||||
if (EMS_Sys_Status.emsLogging == EMS_SYS_LOGGING_BASIC) {
|
||||
@@ -785,7 +785,7 @@ void _ems_processTelegram(_EMS_RxTelegram * EMS_RxTelegram) {
|
||||
}
|
||||
// call callback function to process it
|
||||
// as we only handle complete telegrams (not partial) check that the offset is 0
|
||||
if (offset == EMS_ID_NONE) {
|
||||
if (offset == 0) {
|
||||
(void)EMS_Types[i].processType_cb(src, data, EMS_RxTelegram->length - 5);
|
||||
}
|
||||
}
|
||||
|
||||
Reference in New Issue
Block a user