mirror of
https://github.com/emsesp/EMS-ESP32.git
synced 2026-01-29 01:59:08 +03:00
1.5.7 - fix for core 2.5.0 and wifi issues
This commit is contained in:
@@ -251,6 +251,8 @@ void _renderBoolValue(const char * prefix, uint8_t value) {
|
||||
void showInfo() {
|
||||
// General stats from EMS bus
|
||||
|
||||
char buffer_type[128] = {0};
|
||||
|
||||
myDebug("%sEMS-ESP System stats:%s", COLOR_BOLD_ON, COLOR_BOLD_OFF);
|
||||
_EMS_SYS_LOGGING sysLog = ems_getLogging();
|
||||
if (sysLog == EMS_SYS_LOGGING_BASIC) {
|
||||
@@ -263,9 +265,7 @@ void showInfo() {
|
||||
myDebug(" System logging set to None");
|
||||
}
|
||||
|
||||
myDebug(" LED is %s", EMSESP_Status.led_enabled ? "on" : "off");
|
||||
myDebug(" Test Mode is %s", EMSESP_Status.test_mode ? "on" : "off");
|
||||
|
||||
myDebug(" LED is %s, Test Mode is %s", EMSESP_Status.led_enabled ? "on" : "off", EMSESP_Status.test_mode ? "on" : "off");
|
||||
myDebug(" # connected Dallas temperature sensors=%d", EMSESP_Status.dallas_sensors);
|
||||
|
||||
myDebug(" Thermostat is %s, Boiler is %s, Shower Timer is %s, Shower Alert is %s",
|
||||
@@ -286,19 +286,25 @@ void showInfo() {
|
||||
myDebug("%sBoiler stats:%s", COLOR_BOLD_ON, COLOR_BOLD_OFF);
|
||||
|
||||
// version details
|
||||
char buffer_type[64];
|
||||
myDebug(" Boiler type: %s", ems_getBoilerDescription(buffer_type));
|
||||
|
||||
// active stats
|
||||
if (ems_getBusConnected()) {
|
||||
myDebug(" Hot tap water is %s", (EMS_Boiler.tapwaterActive ? "running" : "off"));
|
||||
myDebug(" Central Heating is %s", (EMS_Boiler.heatingActive ? "active" : "off"));
|
||||
if (EMS_Boiler.tapwaterActive != EMS_VALUE_INT_NOTSET) {
|
||||
myDebug(" Hot tap water is %s", EMS_Boiler.tapwaterActive ? "running" : "off");
|
||||
}
|
||||
|
||||
if (EMS_Boiler.heatingActive != EMS_VALUE_INT_NOTSET) {
|
||||
myDebug(" Central Heating is %s", EMS_Boiler.heatingActive ? "active" : "off");
|
||||
}
|
||||
}
|
||||
|
||||
// UBAParameterWW
|
||||
_renderBoolValue("Warm Water activated", EMS_Boiler.wWActivated);
|
||||
_renderBoolValue("Warm Water circulation pump available", EMS_Boiler.wWCircPump);
|
||||
myDebug(" Warm Water is set to %s", (EMS_Boiler.wWComfort ? "Comfort" : "ECO"));
|
||||
if (EMS_Boiler.wWComfort != EMS_VALUE_INT_NOTSET) {
|
||||
myDebug(" Warm Water is set to %s", (EMS_Boiler.wWComfort ? "Comfort" : "ECO"));
|
||||
}
|
||||
_renderIntValue("Warm Water selected temperature", "C", EMS_Boiler.wWSelTemp);
|
||||
_renderIntValue("Warm Water desired temperature", "C", EMS_Boiler.wWDesiredTemp);
|
||||
|
||||
@@ -392,9 +398,9 @@ void showInfo() {
|
||||
|
||||
// Dallas
|
||||
if (EMSESP_Status.dallas_sensors != 0) {
|
||||
char s[80] = {0};
|
||||
myDebug("%sExternal temperature sensors:%s", COLOR_BOLD_ON, COLOR_BOLD_OFF);
|
||||
for (uint8_t i = 0; i < EMSESP_Status.dallas_sensors; i++) {
|
||||
char s[80] = {0};
|
||||
for (uint8_t i = 0; i < EMSESP_Status.dallas_sensors; i++) {
|
||||
snprintf(s, sizeof(s), "Sensor #%d", i + 1);
|
||||
_renderFloatValue(s, "C", ds18.getValue(i));
|
||||
}
|
||||
@@ -1066,7 +1072,7 @@ void showerCheck() {
|
||||
// if already in cold mode, ignore all this logic until we're out of the cold blast
|
||||
if (!EMSESP_Shower.doingColdShot) {
|
||||
// is the hot water running?
|
||||
if (EMS_Boiler.tapwaterActive) {
|
||||
if (EMS_Boiler.tapwaterActive == 1) {
|
||||
// if heater was previously off, start the timer
|
||||
if (EMSESP_Shower.timerStart == 0) {
|
||||
// hot water just started...
|
||||
@@ -1209,4 +1215,6 @@ void loop() {
|
||||
if (EMSESP_Status.shower_timer) {
|
||||
showerCheck();
|
||||
}
|
||||
|
||||
delay(1); // some time to WiFi and everything else to catch up
|
||||
}
|
||||
|
||||
10
src/ems.cpp
10
src/ems.cpp
@@ -872,11 +872,15 @@ void _processType(uint8_t * telegram, uint8_t length) {
|
||||
* using a quick hack for checking the heating. Selected Flow Temp >= 70
|
||||
*/
|
||||
void _checkActive() {
|
||||
// hot tap water, using flow to check insread of the burner power
|
||||
EMS_Boiler.tapwaterActive = ((EMS_Boiler.wWCurFlow != 0) && (EMS_Boiler.burnGas == EMS_VALUE_INT_ON));
|
||||
// hot tap water, using flow to check instead of the burner power
|
||||
if (EMS_Boiler.wWCurFlow != EMS_VALUE_INT_NOTSET && EMS_Boiler.burnGas != EMS_VALUE_INT_NOTSET) {
|
||||
EMS_Boiler.tapwaterActive = ((EMS_Boiler.wWCurFlow != 0) && (EMS_Boiler.burnGas == EMS_VALUE_INT_ON));
|
||||
}
|
||||
|
||||
// heating
|
||||
EMS_Boiler.heatingActive = ((EMS_Boiler.selFlowTemp >= EMS_BOILER_SELFLOWTEMP_HEATING) && (EMS_Boiler.burnGas == EMS_VALUE_INT_ON));
|
||||
if (EMS_Boiler.selFlowTemp != EMS_VALUE_INT_NOTSET && EMS_Boiler.burnGas != EMS_VALUE_INT_NOTSET) {
|
||||
EMS_Boiler.heatingActive = ((EMS_Boiler.selFlowTemp >= EMS_BOILER_SELFLOWTEMP_HEATING) && (EMS_Boiler.burnGas == EMS_VALUE_INT_ON));
|
||||
}
|
||||
}
|
||||
|
||||
/**
|
||||
|
||||
@@ -6,5 +6,5 @@
|
||||
#pragma once
|
||||
|
||||
#define APP_NAME "EMS-ESP"
|
||||
#define APP_VERSION "1.5.7b"
|
||||
#define APP_VERSION "1.5.7c"
|
||||
#define APP_HOSTNAME "ems-esp"
|
||||
|
||||
Reference in New Issue