add temperatures for low loss header and heatblock, add names BC400/GB192i, #1317

This commit is contained in:
MichaelDvP
2023-10-05 17:56:52 +02:00
parent 895eddd8d2
commit 5e53689a81
5 changed files with 23 additions and 4 deletions

View File

@@ -7,11 +7,12 @@
## Added
- humidity for ventilation devices
- telegrams for RC100H, hc2
- telegrams for RC100H, hc2 (seen on discord)
- names for BC400, GB192i, read temperatures for low loss header and heatblock [#1317](https://github.com/emsesp/EMS-ESP32/discussions/1317)
## Fixed
## Changed
- update to arduion 2.0.13 / idf 4.4.6
- update to arduino 2.0.14 / idf 4.4.6
- small changes for arduino 3.0.0 / idf 5.1 compatibility

View File

@@ -42,7 +42,7 @@
{170, DeviceType::BOILER, "Logano GB212", DeviceFlags::EMS_DEVICE_FLAG_NONE},
{172, DeviceType::BOILER, "Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i", DeviceFlags::EMS_DEVICE_FLAG_HEATPUMP},
{173, DeviceType::BOILER, "Geo 5xx", DeviceFlags::EMS_DEVICE_FLAG_HEATPUMP},
{195, DeviceType::BOILER, "Condens 5000i/Greenstar 8000/GC9800IW", DeviceFlags::EMS_DEVICE_FLAG_NONE},
{195, DeviceType::BOILER, "Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2", DeviceFlags::EMS_DEVICE_FLAG_NONE},
{203, DeviceType::BOILER, "Logamax U122/Cerapur", DeviceFlags::EMS_DEVICE_FLAG_NONE},
{206, DeviceType::BOILER, "Ecomline Excellent", DeviceFlags::EMS_DEVICE_FLAG_NONE},
{208, DeviceType::BOILER, "Logamax Plus/GB192/Condens GC9000/Greenstar ErP", DeviceFlags::EMS_DEVICE_FLAG_NONE},
@@ -81,7 +81,7 @@
{203, DeviceType::THERMOSTAT, "EasyControl CT200", DeviceFlags::EMS_DEVICE_FLAG_EASY | DeviceFlags::EMS_DEVICE_FLAG_NO_WRITE}, // 0x18, cannot write
// Thermostat - Buderus/Nefit/Bosch specific - 0x17 / 0x10 / 0x18 / 0x19-0x1B for hc2-4 / 0x38
{ 4, DeviceType::THERMOSTAT, "UI800", DeviceFlags::EMS_DEVICE_FLAG_RC300}, // 0x10
{ 4, DeviceType::THERMOSTAT, "UI800/BC400", DeviceFlags::EMS_DEVICE_FLAG_RC300}, // 0x10
{ 65, DeviceType::THERMOSTAT, "RC10", DeviceFlags::EMS_DEVICE_FLAG_RC20_N},// 0x17
{ 67, DeviceType::THERMOSTAT, "RC30", DeviceFlags::EMS_DEVICE_FLAG_RC30_N},// 0x10 - based on RC35
{ 77, DeviceType::THERMOSTAT, "RC20/Moduline 300", DeviceFlags::EMS_DEVICE_FLAG_RC20},// 0x17

View File

@@ -156,6 +156,18 @@ Boiler::Boiler(uint8_t device_type, int8_t device_id, uint8_t product_id, const
DeviceValueNumOp::DV_NUMOP_DIV10,
FL_(exhaustTemp),
DeviceValueUOM::DEGREES);
register_device_value(DeviceValueTAG::TAG_DEVICE_DATA,
&heatblock_,
DeviceValueType::USHORT,
DeviceValueNumOp::DV_NUMOP_DIV10,
FL_(heatblock),
DeviceValueUOM::DEGREES);
register_device_value(DeviceValueTAG::TAG_DEVICE_DATA,
&headertemp_,
DeviceValueType::USHORT,
DeviceValueNumOp::DV_NUMOP_DIV10,
FL_(headertemp),
DeviceValueUOM::DEGREES);
register_device_value(DeviceValueTAG::TAG_DEVICE_DATA, &burnGas_, DeviceValueType::BOOL, FL_(burnGas), DeviceValueUOM::NONE);
register_device_value(DeviceValueTAG::TAG_DEVICE_DATA, &burnGas2_, DeviceValueType::BOOL, FL_(burnGas2), DeviceValueUOM::NONE);
register_device_value(DeviceValueTAG::TAG_DEVICE_DATA, &flameCurr_, DeviceValueType::USHORT, DeviceValueNumOp::DV_NUMOP_DIV10, FL_(flameCurr), DeviceValueUOM::UA);
@@ -1158,6 +1170,8 @@ void Boiler::process_UBAMonitorFastPlus(std::shared_ptr<const Telegram> telegram
has_update(telegram, sysPress_, 21);
//has_update(telegram, temperatur_, 13); // unknown temperature
has_update(telegram, heatblock_, 23); // see #1317
has_update(telegram, headertemp_, 25); // see #1317
//has_update(telegram, temperatur_, 27); // unknown temperature
has_update(telegram, exhaustTemp_, 31);

View File

@@ -145,6 +145,8 @@ class Boiler : public EMSdevice {
uint16_t serviceCodeNumber_; // error/service code
uint8_t emergencyOps_;
uint8_t emergencyTemp_;
uint16_t headertemp_; // see #1317
uint16_t heatblock_; // see #1317
// info
uint32_t upTimeControl_; // Operating time control

View File

@@ -336,6 +336,8 @@ MAKE_TRANSLATION(maintenanceTime, "maintenancetime", "time to next maintenance",
MAKE_TRANSLATION(emergencyOps, "emergencyops", "emergency operation", "Notoperation", "Noodoperatie", "Nöddrift", "praca w trybie awaryjnym", "nøddrift", "opération d'urgence", "acil durum çalışması", "operazione di emergenza")
MAKE_TRANSLATION(emergencyTemp, "emergencytemp", "emergency temperature", "Nottemperatur", "Noodtemperatuur", "Nöddrift temperatur", "temperatura w trybie awaryjnym", "nødtemperatur", "température d'urgence", "acil durum sıcaklığı", "temperatura di emergenza")
MAKE_TRANSLATION(pumpMode, "pumpmode", "boiler pump mode", "Kesselpumpen Modus", "Ketelpomp modus", "", "tryb pracy pompy kotła", "pumpemodus", "", "pompa modu", "modalità pompa caldaia") // TODO translate
MAKE_TRANSLATION(headertemp, "headertemp", "low loss header", "Hydr. Weiche", "open verdeler", "", "", "", " bouteille de déc. hydr.", "isı bloğu gidiş suyu sıc.", "comp. idr.") // TODO translate
MAKE_TRANSLATION(heatblock, "heatblock", "heating block", "Wärmezelle", "Aanvoertemp. warmtecel", "", "", "", "départ corps de chauffe", "Hid.denge kabı sıcaklığı", "mandata scamb. pr.") // TODO translate
// heatpump/compress specific
MAKE_TRANSLATION(upTimeControl, "uptimecontrol", "total operating time heat", "Betriebszeit Heizen gesamt", "Totale bedrijfstijd", "Total tid uppvärmning", "łączny czas generowania ciepła", "total driftstid", "durée totale de fonctionnement chauffage", "ısınma toplam işletme süresi", "Tempo di funzionamento totale riscaldamento")