mirror of
https://github.com/emsesp/EMS-ESP32.git
synced 2025-12-08 08:49:52 +03:00
add temperatures for low loss header and heatblock, add names BC400/GB192i, #1317
This commit is contained in:
@@ -7,11 +7,12 @@
|
||||
## Added
|
||||
|
||||
- humidity for ventilation devices
|
||||
- telegrams for RC100H, hc2
|
||||
- telegrams for RC100H, hc2 (seen on discord)
|
||||
- names for BC400, GB192i, read temperatures for low loss header and heatblock [#1317](https://github.com/emsesp/EMS-ESP32/discussions/1317)
|
||||
|
||||
## Fixed
|
||||
|
||||
## Changed
|
||||
|
||||
- update to arduion 2.0.13 / idf 4.4.6
|
||||
- update to arduino 2.0.14 / idf 4.4.6
|
||||
- small changes for arduino 3.0.0 / idf 5.1 compatibility
|
||||
|
||||
@@ -42,7 +42,7 @@
|
||||
{170, DeviceType::BOILER, "Logano GB212", DeviceFlags::EMS_DEVICE_FLAG_NONE},
|
||||
{172, DeviceType::BOILER, "Enviline/Compress 6000AW/Hybrid 3000-7000iAW/SupraEco/Geo 5xx/WLW196i/WSW196i", DeviceFlags::EMS_DEVICE_FLAG_HEATPUMP},
|
||||
{173, DeviceType::BOILER, "Geo 5xx", DeviceFlags::EMS_DEVICE_FLAG_HEATPUMP},
|
||||
{195, DeviceType::BOILER, "Condens 5000i/Greenstar 8000/GC9800IW", DeviceFlags::EMS_DEVICE_FLAG_NONE},
|
||||
{195, DeviceType::BOILER, "Condens 5000i/Greenstar 8000/GC9800IW/GB192i.2", DeviceFlags::EMS_DEVICE_FLAG_NONE},
|
||||
{203, DeviceType::BOILER, "Logamax U122/Cerapur", DeviceFlags::EMS_DEVICE_FLAG_NONE},
|
||||
{206, DeviceType::BOILER, "Ecomline Excellent", DeviceFlags::EMS_DEVICE_FLAG_NONE},
|
||||
{208, DeviceType::BOILER, "Logamax Plus/GB192/Condens GC9000/Greenstar ErP", DeviceFlags::EMS_DEVICE_FLAG_NONE},
|
||||
@@ -81,7 +81,7 @@
|
||||
{203, DeviceType::THERMOSTAT, "EasyControl CT200", DeviceFlags::EMS_DEVICE_FLAG_EASY | DeviceFlags::EMS_DEVICE_FLAG_NO_WRITE}, // 0x18, cannot write
|
||||
|
||||
// Thermostat - Buderus/Nefit/Bosch specific - 0x17 / 0x10 / 0x18 / 0x19-0x1B for hc2-4 / 0x38
|
||||
{ 4, DeviceType::THERMOSTAT, "UI800", DeviceFlags::EMS_DEVICE_FLAG_RC300}, // 0x10
|
||||
{ 4, DeviceType::THERMOSTAT, "UI800/BC400", DeviceFlags::EMS_DEVICE_FLAG_RC300}, // 0x10
|
||||
{ 65, DeviceType::THERMOSTAT, "RC10", DeviceFlags::EMS_DEVICE_FLAG_RC20_N},// 0x17
|
||||
{ 67, DeviceType::THERMOSTAT, "RC30", DeviceFlags::EMS_DEVICE_FLAG_RC30_N},// 0x10 - based on RC35
|
||||
{ 77, DeviceType::THERMOSTAT, "RC20/Moduline 300", DeviceFlags::EMS_DEVICE_FLAG_RC20},// 0x17
|
||||
|
||||
@@ -156,6 +156,18 @@ Boiler::Boiler(uint8_t device_type, int8_t device_id, uint8_t product_id, const
|
||||
DeviceValueNumOp::DV_NUMOP_DIV10,
|
||||
FL_(exhaustTemp),
|
||||
DeviceValueUOM::DEGREES);
|
||||
register_device_value(DeviceValueTAG::TAG_DEVICE_DATA,
|
||||
&heatblock_,
|
||||
DeviceValueType::USHORT,
|
||||
DeviceValueNumOp::DV_NUMOP_DIV10,
|
||||
FL_(heatblock),
|
||||
DeviceValueUOM::DEGREES);
|
||||
register_device_value(DeviceValueTAG::TAG_DEVICE_DATA,
|
||||
&headertemp_,
|
||||
DeviceValueType::USHORT,
|
||||
DeviceValueNumOp::DV_NUMOP_DIV10,
|
||||
FL_(headertemp),
|
||||
DeviceValueUOM::DEGREES);
|
||||
register_device_value(DeviceValueTAG::TAG_DEVICE_DATA, &burnGas_, DeviceValueType::BOOL, FL_(burnGas), DeviceValueUOM::NONE);
|
||||
register_device_value(DeviceValueTAG::TAG_DEVICE_DATA, &burnGas2_, DeviceValueType::BOOL, FL_(burnGas2), DeviceValueUOM::NONE);
|
||||
register_device_value(DeviceValueTAG::TAG_DEVICE_DATA, &flameCurr_, DeviceValueType::USHORT, DeviceValueNumOp::DV_NUMOP_DIV10, FL_(flameCurr), DeviceValueUOM::UA);
|
||||
@@ -1158,6 +1170,8 @@ void Boiler::process_UBAMonitorFastPlus(std::shared_ptr<const Telegram> telegram
|
||||
has_update(telegram, sysPress_, 21);
|
||||
|
||||
//has_update(telegram, temperatur_, 13); // unknown temperature
|
||||
has_update(telegram, heatblock_, 23); // see #1317
|
||||
has_update(telegram, headertemp_, 25); // see #1317
|
||||
//has_update(telegram, temperatur_, 27); // unknown temperature
|
||||
|
||||
has_update(telegram, exhaustTemp_, 31);
|
||||
|
||||
@@ -145,6 +145,8 @@ class Boiler : public EMSdevice {
|
||||
uint16_t serviceCodeNumber_; // error/service code
|
||||
uint8_t emergencyOps_;
|
||||
uint8_t emergencyTemp_;
|
||||
uint16_t headertemp_; // see #1317
|
||||
uint16_t heatblock_; // see #1317
|
||||
|
||||
// info
|
||||
uint32_t upTimeControl_; // Operating time control
|
||||
|
||||
@@ -336,6 +336,8 @@ MAKE_TRANSLATION(maintenanceTime, "maintenancetime", "time to next maintenance",
|
||||
MAKE_TRANSLATION(emergencyOps, "emergencyops", "emergency operation", "Notoperation", "Noodoperatie", "Nöddrift", "praca w trybie awaryjnym", "nøddrift", "opération d'urgence", "acil durum çalışması", "operazione di emergenza")
|
||||
MAKE_TRANSLATION(emergencyTemp, "emergencytemp", "emergency temperature", "Nottemperatur", "Noodtemperatuur", "Nöddrift temperatur", "temperatura w trybie awaryjnym", "nødtemperatur", "température d'urgence", "acil durum sıcaklığı", "temperatura di emergenza")
|
||||
MAKE_TRANSLATION(pumpMode, "pumpmode", "boiler pump mode", "Kesselpumpen Modus", "Ketelpomp modus", "", "tryb pracy pompy kotła", "pumpemodus", "", "pompa modu", "modalità pompa caldaia") // TODO translate
|
||||
MAKE_TRANSLATION(headertemp, "headertemp", "low loss header", "Hydr. Weiche", "open verdeler", "", "", "", " bouteille de déc. hydr.", "isı bloğu gidiş suyu sıc.", "comp. idr.") // TODO translate
|
||||
MAKE_TRANSLATION(heatblock, "heatblock", "heating block", "Wärmezelle", "Aanvoertemp. warmtecel", "", "", "", "départ corps de chauffe", "Hid.denge kabı sıcaklığı", "mandata scamb. pr.") // TODO translate
|
||||
|
||||
// heatpump/compress specific
|
||||
MAKE_TRANSLATION(upTimeControl, "uptimecontrol", "total operating time heat", "Betriebszeit Heizen gesamt", "Totale bedrijfstijd", "Total tid uppvärmning", "łączny czas generowania ciepła", "total driftstid", "durée totale de fonctionnement chauffage", "ısınma toplam işletme süresi", "Tempo di funzionamento totale riscaldamento")
|
||||
|
||||
Reference in New Issue