@@ -264,10 +264,10 @@ void ems_init() {
|
||||
EMS_Boiler.pump_mod_min = EMS_VALUE_INT_NOTSET; // Boiler circuit pump modulation min. power
|
||||
|
||||
// Other EMS devices values
|
||||
EMS_Other.SM10collectorTemp = EMS_VALUE_SHORT_NOTSET; // collector temp from SM10
|
||||
EMS_Other.SM10bottomTemp = EMS_VALUE_SHORT_NOTSET; // bottom temp from SM10
|
||||
EMS_Other.SM10pumpModulation = EMS_VALUE_INT_NOTSET; // modulation solar pump SM10
|
||||
EMS_Other.SM10pump = EMS_VALUE_INT_NOTSET; // pump active
|
||||
EMS_Other.SMcollectorTemp = EMS_VALUE_SHORT_NOTSET; // collector temp from SM10/SM100
|
||||
EMS_Other.SMbottomTemp = EMS_VALUE_SHORT_NOTSET; // bottom temp from SM10/SM100
|
||||
EMS_Other.SMpumpModulation = EMS_VALUE_INT_NOTSET; // modulation solar pump SM10/SM100
|
||||
EMS_Other.SMpump = EMS_VALUE_INT_NOTSET; // pump active
|
||||
|
||||
// calculated values
|
||||
EMS_Boiler.tapwaterActive = EMS_VALUE_INT_NOTSET; // Hot tap water is on/off
|
||||
@@ -283,7 +283,7 @@ void ems_init() {
|
||||
strlcpy(EMS_Thermostat.version, "?", sizeof(EMS_Thermostat.version));
|
||||
|
||||
// set other types
|
||||
EMS_Other.SM10 = false;
|
||||
EMS_Other.SM = false;
|
||||
|
||||
// default logging is none
|
||||
ems_setLogging(EMS_SYS_LOGGING_DEFAULT);
|
||||
@@ -790,8 +790,8 @@ void _printMessage(_EMS_RxTelegram * EMS_RxTelegram) {
|
||||
strlcat(output_str, "Boiler", sizeof(output_str));
|
||||
strlcpy(color_s, COLOR_MAGENTA, sizeof(color_s));
|
||||
}
|
||||
} else if (dest == EMS_ID_SM10) {
|
||||
strlcat(output_str, "SM10", sizeof(output_str));
|
||||
} else if (dest == EMS_ID_SM) {
|
||||
strlcat(output_str, "SM", sizeof(output_str));
|
||||
strlcpy(color_s, COLOR_MAGENTA, sizeof(color_s));
|
||||
} else if (dest == EMS_Thermostat.type_id) {
|
||||
if (emsp) {
|
||||
@@ -860,7 +860,7 @@ void _ems_processTelegram(_EMS_RxTelegram * EMS_RxTelegram) {
|
||||
// is it common type for everyone?
|
||||
// is it for us? So the src must match with either the boiler, thermostat or other devices
|
||||
if ((EMS_Types[i].model_id == EMS_MODEL_ALL)
|
||||
|| ((src == EMS_Boiler.type_id) || (src == EMS_Thermostat.type_id) || (src == EMS_ID_SM10))) {
|
||||
|| ((src == EMS_Boiler.type_id) || (src == EMS_Thermostat.type_id) || (src == EMS_ID_SM))) {
|
||||
typeFound = true;
|
||||
break;
|
||||
}
|
||||
@@ -1266,10 +1266,10 @@ void _process_RCOutdoorTempMessage(uint8_t src, uint8_t * data, uint8_t length)
|
||||
* SM10Monitor - type 0x97
|
||||
*/
|
||||
void _process_SM10Monitor(uint8_t src, uint8_t * data, uint8_t length) {
|
||||
EMS_Other.SM10collectorTemp = _toShort(2); // collector temp from SM10, is *10
|
||||
EMS_Other.SM10bottomTemp = _toShort(5); // bottom temp from SM10, is *10
|
||||
EMS_Other.SM10pumpModulation = _toByte(4); // modulation solar pump
|
||||
EMS_Other.SM10pump = _bitRead(7, 1); // active if bit 1 is set
|
||||
EMS_Other.SMcollectorTemp = _toShort(2); // collector temp from SM10/SM100, is *10
|
||||
EMS_Other.SMbottomTemp = _toShort(5); // bottom temp from SM10/SM100, is *10
|
||||
EMS_Other.SMpumpModulation = _toByte(4); // modulation solar pump
|
||||
EMS_Other.SMpump = _bitRead(7, 1); // active if bit 1 is set
|
||||
|
||||
EMS_Sys_Status.emsRefreshed = true; // triggers a send the values back via MQTT
|
||||
}
|
||||
@@ -1462,8 +1462,8 @@ void _process_Version(uint8_t src, uint8_t * data, uint8_t length) {
|
||||
_addDevice(product_id, Other_Types[i].type_id, version, Other_Types[i].model_string);
|
||||
|
||||
// see if this is a Solar Module SM10
|
||||
if (Other_Types[i].type_id == EMS_ID_SM10) {
|
||||
EMS_Other.SM10 = true; // we have detected a SM10
|
||||
if (Other_Types[i].type_id == EMS_ID_SM) {
|
||||
EMS_Other.SM = true; // we have detected a SM10
|
||||
myDebug("SM10 Solar Module support enabled.");
|
||||
}
|
||||
|
||||
@@ -1489,7 +1489,7 @@ void ems_discoverModels() {
|
||||
ems_doReadCommand(EMS_TYPE_Version, EMS_Boiler.type_id); // get version details of boiler
|
||||
|
||||
// solar module
|
||||
ems_doReadCommand(EMS_TYPE_Version, EMS_ID_SM10); // check if there is Solar Module available
|
||||
ems_doReadCommand(EMS_TYPE_Version, EMS_ID_SM); // check if there is Solar Module available
|
||||
|
||||
// thermostat
|
||||
// if it hasn't been set, auto discover it
|
||||
@@ -1607,8 +1607,8 @@ void ems_getBoilerValues() {
|
||||
* Get other values from EMS devices
|
||||
*/
|
||||
void ems_getOtherValues() {
|
||||
if (EMS_Other.SM10) {
|
||||
ems_doReadCommand(EMS_TYPE_SM10Monitor, EMS_ID_SM10); // fetch all from SM10Monitor, e.g. 0B B0 97 00 16
|
||||
if (EMS_Other.SM) {
|
||||
ems_doReadCommand(EMS_TYPE_SM10Monitor, EMS_ID_SM); // fetch all from SM10Monitor, e.g. 0B B0 97 00 16
|
||||
}
|
||||
}
|
||||
|
||||
@@ -1766,8 +1766,18 @@ void ems_printAllDevices() {
|
||||
(Thermostat_Types[i].write_supported) ? 'y' : 'n');
|
||||
}
|
||||
|
||||
// print out known devices
|
||||
ems_printDevices();
|
||||
|
||||
myDebug(""); // newline
|
||||
}
|
||||
|
||||
/*
|
||||
* print out contents of the device list that was captured
|
||||
*/
|
||||
void ems_printDevices() {
|
||||
if (Devices.size() != 0) {
|
||||
myDebug("\nThese %d EMS devices were detected on your system:", Devices.size());
|
||||
myDebug("\nThese %d EMS devices were detected:", Devices.size());
|
||||
for (std::list<_Generic_Type>::iterator it = Devices.begin(); it != Devices.end(); it++) {
|
||||
myDebug(" %s%s%s (TypeID:0x%02X ProductID:%d Version:%s)",
|
||||
COLOR_BOLD_ON,
|
||||
@@ -1777,9 +1787,9 @@ void ems_printAllDevices() {
|
||||
(it)->product_id,
|
||||
(it)->version);
|
||||
}
|
||||
}
|
||||
|
||||
myDebug(""); // newline
|
||||
myDebug("\nIf any are marked as 'unknown', please report as a GitHub issue so we can update the EMS devices database.\n");
|
||||
}
|
||||
}
|
||||
|
||||
/**
|
||||
|
||||