mirror of
https://github.com/emsesp/EMS-ESP32.git
synced 2025-12-08 00:39:50 +03:00
HIU heating/tapwater-active, always use EMSdevice:: for flags
This commit is contained in:
@@ -179,7 +179,7 @@ Boiler::Boiler(uint8_t device_type, int8_t device_id, uint8_t product_id, const
|
||||
DeviceValueUOM::DEGREES);
|
||||
|
||||
// exclude burner related entities from heatpump and HIU
|
||||
if (model() != EMS_DEVICE_FLAG_HEATPUMP && model() != EMS_DEVICE_FLAG_HIU) {
|
||||
if (model() != EMSdevice::EMS_DEVICE_FLAG_HEATPUMP && model() != EMSdevice::EMS_DEVICE_FLAG_HIU) {
|
||||
register_device_value(DeviceValueTAG::TAG_DEVICE_DATA,
|
||||
&exhaustTemp_,
|
||||
DeviceValueType::USHORT,
|
||||
@@ -367,7 +367,7 @@ Boiler::Boiler(uint8_t device_type, int8_t device_id, uint8_t product_id, const
|
||||
*/
|
||||
|
||||
// heatpump info
|
||||
if (model() == EMS_DEVICE_FLAG_HEATPUMP) {
|
||||
if (model() == EMSdevice::EMS_DEVICE_FLAG_HEATPUMP) {
|
||||
register_device_value(DeviceValueTAG::TAG_DEVICE_DATA,
|
||||
&nrgTotal_,
|
||||
DeviceValueType::ULONG,
|
||||
@@ -945,7 +945,7 @@ Boiler::Boiler(uint8_t device_type, int8_t device_id, uint8_t product_id, const
|
||||
EMSESP::send_read_request(0xC2, device_id); // read last errorcode on start (only published on errors)
|
||||
|
||||
|
||||
if (model() != EMS_DEVICE_FLAG_HEATPUMP && model() != EMS_DEVICE_FLAG_HIU) {
|
||||
if (model() != EMSdevice::EMS_DEVICE_FLAG_HEATPUMP && model() != EMSdevice::EMS_DEVICE_FLAG_HIU) {
|
||||
register_telegram_type(0x04, "UBAFactory", true, MAKE_PF_CB(process_UBAFactory));
|
||||
register_device_value(DeviceValueTAG::TAG_DEVICE_DATA, &nomPower_, DeviceValueType::UINT, FL_(nomPower), DeviceValueUOM::KW, MAKE_CF_CB(set_nomPower));
|
||||
register_device_value(DeviceValueTAG::TAG_DEVICE_DATA,
|
||||
@@ -1066,7 +1066,7 @@ void Boiler::check_active() {
|
||||
}
|
||||
|
||||
// calculate energy for boiler 0x08 from stored modulation an time in units of 0.01 Wh
|
||||
if (model() != EMS_DEVICE_FLAG_HEATPUMP) {
|
||||
if (model() != EMSdevice::EMS_DEVICE_FLAG_HEATPUMP && model() != EMSdevice::EMS_DEVICE_FLAG_HIU) {
|
||||
// remember values from last call
|
||||
static uint32_t powLastReadTime_ = uuid::get_uptime();
|
||||
static uint8_t heatBurnPow = 0;
|
||||
@@ -1309,7 +1309,7 @@ void Boiler::process_UBAMonitorFastPlus(std::shared_ptr<const Telegram> telegram
|
||||
|
||||
// at this point do a quick check to see if the hot water or heating is active
|
||||
uint8_t state = EMS_VALUE_UINT_NOTSET;
|
||||
if (telegram->read_value(state, 11)) {
|
||||
if (telegram->read_value(state, 11) && model() != EMSdevice::EMS_DEVICE_FLAG_HIU) {
|
||||
boilerState_ = state & 0x01 ? 0x08 : 0;
|
||||
boilerState_ |= state & 0x02 ? 0x01 : 0;
|
||||
boilerState_ |= state & 0x04 ? 0x02 : 0;
|
||||
@@ -1348,6 +1348,17 @@ void Boiler::process_UBAMonitorSlow(std::shared_ptr<const Telegram> telegram) {
|
||||
*/
|
||||
void Boiler::process_UBAMonitorSlowPlus2(std::shared_ptr<const Telegram> telegram) {
|
||||
has_update(telegram, absBurnPow_, 13); // current burner absolute power (percent of rating plate power)
|
||||
if (model() == EMSdevice::EMS_DEVICE_FLAG_HIU) {
|
||||
uint8_t state = EMS_VALUE_UINT_NOTSET;
|
||||
boilerState_ = 0;
|
||||
if (telegram->read_value(state, 2)) {
|
||||
boilerState_ |= state == 1 ? 0x09 : 0; // heating 0/1
|
||||
}
|
||||
state = EMS_VALUE_UINT_NOTSET;
|
||||
if (telegram->read_value(state, 5)) {
|
||||
boilerState_ |= state == 1 ? 0x0A : 0; // dhw 0/1
|
||||
}
|
||||
}
|
||||
}
|
||||
|
||||
/*
|
||||
|
||||
Reference in New Issue