mirror of
https://github.com/emsesp/EMS-ESP32.git
synced 2025-12-07 08:19:52 +03:00
Merge branch 'dev' of https://github.com/proddy/EMS-ESP.git into MM10
This commit is contained in:
@@ -37,3 +37,5 @@ SpaceAfterCStyleCast: false
|
||||
SpaceBeforeAssignmentOperators: true
|
||||
SpacesInCStyleCastParentheses: false
|
||||
SpacesInParentheses: false
|
||||
DerivePointerAlignment: false
|
||||
SortIncludes: false
|
||||
@@ -1,4 +1,5 @@
|
||||
os: linux
|
||||
dist: bionic
|
||||
language: python
|
||||
python:
|
||||
- "3.8"
|
||||
@@ -55,7 +56,7 @@ before_deploy:
|
||||
deploy:
|
||||
provider: releases
|
||||
edge:
|
||||
source: wenkokke/dpl
|
||||
# source: wenkokke/dpl
|
||||
branch: master
|
||||
token: ${GITHUB_TOKEN}
|
||||
file_glob: true
|
||||
|
||||
@@ -15,6 +15,8 @@ and this project adheres to [Semantic Versioning](https://semver.org/spec/v2.0.0
|
||||
|
||||
### Fixed
|
||||
- set boiler warm water temp on Junkers/Bosch HT3
|
||||
- fixed detection of the Moduline 400 thermostat
|
||||
- RC35 setting temperature also forces the current select temp to change, irrespective of the mode
|
||||
|
||||
### Changed
|
||||
- improved MQTT publishing to stop flooding. `publish_time` must be at least 1 (second)
|
||||
|
||||
@@ -479,7 +479,7 @@ void showInfo() {
|
||||
if (ems_getMixingDeviceEnabled()) {
|
||||
myDebug_P(PSTR("")); // newline
|
||||
myDebug_P(PSTR("%sMixing module data:%s"), COLOR_BOLD_ON, COLOR_BOLD_OFF);
|
||||
myDebug_P(PSTR(" Mixing: %s"), ems_getDeviceDescription(EMS_DEVICE_TYPE_MIXING, buffer_type,false));
|
||||
// myDebug_P(PSTR(" Mixing: %s"), ems_getDeviceDescription(EMS_DEVICE_TYPE_MIXING, buffer_type,false));
|
||||
if (EMS_Boiler.switchTemp < EMS_VALUE_USHORT_NOTSET)
|
||||
_renderUShortValue("Switch temperature", "C", EMS_Boiler.switchTemp);
|
||||
|
||||
@@ -951,7 +951,7 @@ void do_regularUpdates() {
|
||||
// turn back on the hot water for the shower
|
||||
void _showerColdShotStop() {
|
||||
if (EMSESP_Shower.doingColdShot) {
|
||||
myDebugLog("[Shower] finished shot of cold. hot water back on");
|
||||
myDebugLog("[Shower] finished shot of cold water. Hot water turned back on");
|
||||
ems_setWarmTapWaterActivated(true);
|
||||
EMSESP_Shower.doingColdShot = false;
|
||||
showerColdShotStopTimer.detach(); // disable the timer
|
||||
@@ -961,7 +961,7 @@ void _showerColdShotStop() {
|
||||
// turn off hot water to send a shot of cold
|
||||
void _showerColdShotStart() {
|
||||
if (EMSESP_Settings.shower_alert) {
|
||||
myDebugLog("[Shower] doing a shot of cold water");
|
||||
myDebugLog("[Shower] starting shot of cold water");
|
||||
ems_setWarmTapWaterActivated(false);
|
||||
EMSESP_Shower.doingColdShot = true;
|
||||
// start the timer for n seconds which will reset the water back to hot
|
||||
@@ -1975,9 +1975,9 @@ void showerCheck() {
|
||||
// SETUP
|
||||
//
|
||||
void setup() {
|
||||
// GPIO15/D8 has a pull down, so we must set it to HIGH so it doesn't bring the whole EMS bus down
|
||||
// GPIO15/D8 has an onboard pull down resistor and we use this for Tx, so force it high so it doesn't bring the whole EMS bus down
|
||||
pinMode(D8, OUTPUT);
|
||||
digitalWrite(D8, 1);
|
||||
digitalWrite(D8, HIGH);
|
||||
|
||||
// init our own parameters
|
||||
initEMSESP();
|
||||
|
||||
@@ -2369,11 +2369,15 @@ void ems_setThermostatTemp(float temperature, uint8_t hc_num, uint8_t temptype)
|
||||
break;
|
||||
default:
|
||||
case 0: // automatic selection, if no type is defined, we use the standard code
|
||||
EMS_TxTelegram.offset = EMS_OFFSET_RC35Set_seltemp;
|
||||
|
||||
/* commented out for https://github.com/proddy/EMS-ESP/issues/310
|
||||
if (EMS_Thermostat.hc[hc_num - 1].day_mode == 0) {
|
||||
EMS_TxTelegram.offset = EMS_OFFSET_RC35Set_temp_night;
|
||||
} else if (EMS_Thermostat.hc[hc_num - 1].day_mode == 1) {
|
||||
EMS_TxTelegram.offset = EMS_OFFSET_RC35Set_temp_day;
|
||||
}
|
||||
*/
|
||||
break;
|
||||
}
|
||||
|
||||
@@ -2719,7 +2723,7 @@ void ems_setWarmTapWaterActivated(bool activated) {
|
||||
EMS_TxTelegram.data[3] = EMS_TxTelegram.offset; // offset
|
||||
|
||||
// we use the special test mode 0x1D for this. Setting the first data to 5A puts the system into test mode and
|
||||
// a setting of 0x00 puts it back into normal operarting mode
|
||||
// a setting of 0x00 puts it back into normal operating mode
|
||||
// when in test mode we're able to mess around with the 3-way valve settings
|
||||
if (!activated) {
|
||||
// on
|
||||
|
||||
@@ -121,9 +121,10 @@
|
||||
#define EMS_OFFSET_RC35Set_mode 7 // position of thermostat mode
|
||||
#define EMS_OFFSET_RC35Set_temp_day 2 // position of thermostat setpoint temperature for day time
|
||||
#define EMS_OFFSET_RC35Set_temp_night 1 // position of thermostat setpoint temperature for night time
|
||||
#define EMS_OFFSET_RC35Set_temp_holiday 3 // temp during holiday 0x47
|
||||
#define EMS_OFFSET_RC35Set_heatingtype 0 // floor heating = 3 0x47
|
||||
#define EMS_OFFSET_RC35Set_circuitcalctemp 14 // calculated circuit temperature 0x48
|
||||
#define EMS_OFFSET_RC35Set_temp_holiday 3 // temp during holiday mode
|
||||
#define EMS_OFFSET_RC35Set_heatingtype 0 // e.g. floor heating = 3
|
||||
#define EMS_OFFSET_RC35Set_circuitcalctemp 14 // calculated circuit temperature
|
||||
#define EMS_OFFSET_RC35Set_seltemp 37 // selected temp
|
||||
|
||||
// Easy specific
|
||||
#define EMS_TYPE_EasyStatusMessage 0x0A // reading values on an Easy Thermostat
|
||||
|
||||
@@ -1 +1 @@
|
||||
#define APP_VERSION "1.9.5b18m"
|
||||
#define APP_VERSION "1.9.5b19"
|
||||
|
||||
Reference in New Issue