@@ -63,41 +63,46 @@
|
||||
|
||||
// RC10 specific
|
||||
#define EMS_TYPE_RC10StatusMessage 0xB1 // is an automatic thermostat broadcast giving us temps
|
||||
#define EMS_TYPE_RC10Set 0xB0 // for setting values like temp and mode
|
||||
#define EMS_OFFSET_RC10Set_temp 4 // position of thermostat setpoint temperature
|
||||
#define EMS_OFFSET_RC10StatusMessage_setpoint 1 // setpoint temp
|
||||
#define EMS_OFFSET_RC10StatusMessage_curr 2 // current temp
|
||||
|
||||
#define EMS_TYPE_RC10Set 0xB0 // for setting values like temp and mode
|
||||
#define EMS_OFFSET_RC10Set_temp 4 // position of thermostat setpoint temperature
|
||||
|
||||
// RC20 specific
|
||||
#define EMS_TYPE_RC20StatusMessage 0x91 // is an automatic thermostat broadcast giving us temps
|
||||
#define EMS_TYPE_RC20Set 0xA8 // for setting values like temp and mode
|
||||
#define EMS_OFFSET_RC20Set_mode 23 // position of thermostat mode
|
||||
#define EMS_OFFSET_RC20Set_temp 28 // position of thermostat setpoint temperature
|
||||
#define EMS_OFFSET_RC20StatusMessage_setpoint 1 // setpoint temp
|
||||
#define EMS_OFFSET_RC20StatusMessage_curr 2 // current temp
|
||||
|
||||
#define EMS_TYPE_RC20Set 0xA8 // for setting values like temp and mode
|
||||
#define EMS_OFFSET_RC20Set_mode 23 // position of thermostat mode
|
||||
#define EMS_OFFSET_RC20Set_temp 28 // position of thermostat setpoint temperature
|
||||
|
||||
// RC30 specific
|
||||
#define EMS_TYPE_RC30StatusMessage 0x41 // is an automatic thermostat broadcast giving us temps
|
||||
#define EMS_TYPE_RC30Set 0xA7 // for setting values like temp and mode
|
||||
#define EMS_OFFSET_RC30Set_mode 23 // position of thermostat mode
|
||||
#define EMS_OFFSET_RC30Set_temp 28 // position of thermostat setpoint temperature
|
||||
#define EMS_OFFSET_RC30StatusMessage_setpoint 1 // setpoint temp
|
||||
#define EMS_OFFSET_RC30StatusMessage_curr 2 // current temp
|
||||
|
||||
#define EMS_TYPE_RC30Set 0xA7 // for setting values like temp and mode
|
||||
#define EMS_OFFSET_RC30Set_mode 23 // position of thermostat mode
|
||||
#define EMS_OFFSET_RC30Set_temp 28 // position of thermostat setpoint temperature
|
||||
|
||||
|
||||
// RC35 specific
|
||||
#define EMS_TYPE_RC35StatusMessage_HC1 0x3E // is an automatic thermostat broadcast giving us temps on HC1
|
||||
#define EMS_TYPE_RC35StatusMessage_HC2 0x48 // is an automatic thermostat broadcast giving us temps on HC2
|
||||
#define EMS_TYPE_RC35Set_HC1 0x3D // for setting values like temp and mode (Working mode HC1)
|
||||
#define EMS_TYPE_RC35Set_HC2 0x47 // for setting values like temp and mode (Working mode HC2)
|
||||
#define EMS_OFFSET_RC35StatusMessage_setpoint 2 // desired temp
|
||||
#define EMS_OFFSET_RC35StatusMessage_curr 3 // current temp
|
||||
#define EMS_OFFSET_RC35Set_mode 7 // position of thermostat mode
|
||||
#define EMS_OFFSET_RC35Set_temp_day 2 // position of thermostat setpoint temperature for day time
|
||||
#define EMS_OFFSET_RC35Set_temp_night 1 // position of thermostat setpoint temperature for night time
|
||||
#define EMS_OFFSET_RC35Get_mode_day 1 // position of thermostat day mode
|
||||
#define EMS_OFFSET_RC35Set_temp_holiday 3 // temp during holiday 0x47
|
||||
#define EMS_OFFSET_RC35Set_heatingtype 0 // floor heating = 3 0x47
|
||||
#define EMS_OFFSET_RC35Set_circuitcalctemp 14 // calculated circuit temperature 0x48
|
||||
#define EMS_OFFSET_RC35StatusMessage_mode 1 //day mode
|
||||
|
||||
#define EMS_TYPE_RC35Set_HC1 0x3D // for setting values like temp and mode (Working mode HC1)
|
||||
#define EMS_TYPE_RC35Set_HC2 0x47 // for setting values like temp and mode (Working mode HC2)
|
||||
#define EMS_OFFSET_RC35Set_mode 7 // position of thermostat mode
|
||||
#define EMS_OFFSET_RC35Set_temp_day 2 // position of thermostat setpoint temperature for day time
|
||||
#define EMS_OFFSET_RC35Set_temp_night 1 // position of thermostat setpoint temperature for night time
|
||||
#define EMS_OFFSET_RC35Set_temp_holiday 3 // temp during holiday 0x47
|
||||
#define EMS_OFFSET_RC35Set_heatingtype 0 // floor heating = 3 0x47
|
||||
#define EMS_OFFSET_RC35Set_circuitcalctemp 14 // calculated circuit temperature 0x48
|
||||
|
||||
// Easy specific
|
||||
#define EMS_TYPE_EasyStatusMessage 0x0A // reading values on an Easy Thermostat
|
||||
@@ -105,18 +110,20 @@
|
||||
#define EMS_OFFSET_EasyStatusMessage_curr 8 // current temp
|
||||
|
||||
// RC1010, RC310 and RC300 specific (EMS Plus)
|
||||
#define EMS_TYPE_RCPLUSStatusMessage 0x01A5 // is an automatic thermostat broadcast giving us temps
|
||||
#define EMS_TYPE_RCPLUSStatusMessage 0x01A5 // is an automatic thermostat broadcast giving us temps, also reading
|
||||
#define EMS_TYPE_RCPLUSStatusMode 0x1AF // summer/winter mode
|
||||
#define EMS_TYPE_RCPLUSSet 0x01B9 // setpoint temp message and mode
|
||||
#define EMS_OFFSET_RCPLUSStatusMessage_mode 10 // thermostat mode (auto, manual)
|
||||
#define EMS_OFFSET_RCPLUSStatusMessage_setpoint 3 // setpoint temp
|
||||
#define EMS_OFFSET_RCPLUSStatusMessage_curr 0 // current temp
|
||||
#define EMS_OFFSET_RCPLUSGet_mode_day 10 // day/night mode
|
||||
#define EMS_OFFSET_RCPLUSSet_mode 0 // operation mode (Auto=xFF, Manual=x00)
|
||||
#define EMS_OFFSET_RCPLUSStatusMessage_mode 0x0A // thermostat mode (auto, manual)
|
||||
#define EMS_OFFSET_RCPLUSSet_temp_comfort3 1 // comfort3 level
|
||||
#define EMS_OFFSET_RCPLUSSet_temp_comfort2 2 // comfort2 level
|
||||
#define EMS_OFFSET_RCPLUSSet_temp_comfort1 3 // comfort1 level
|
||||
#define EMS_OFFSET_RCPLUSSet_temp_eco 4 // eco level
|
||||
|
||||
#define EMS_TYPE_RCPLUSSet 0x01B9 // setpoint temp message and mode
|
||||
#define EMS_OFFSET_RCPLUSSet_mode 0 // operation mode(Auto=0xFF, Manual=0x00)
|
||||
#define EMS_OFFSET_RCPLUSSet_temp_comfort3 1 // comfort3 level
|
||||
#define EMS_OFFSET_RCPLUSSet_temp_comfort2 2 // comfort2 level
|
||||
#define EMS_OFFSET_RCPLUSSet_temp_comfort1 3 // comfort1 level
|
||||
#define EMS_OFFSET_RCPLUSSet_temp_eco 4 // eco level
|
||||
#define EMS_OFFSET_RCPLUSSet_temp_setpoint 8 // temp setpoint, when changing of templevel (in auto) value is reset and set to FF
|
||||
#define EMS_OFFSET_RCPLUSSet_manual_setpoint 10 // manual setpoint
|
||||
|
||||
// Junkers FR10, FW100 (EMS Plus)
|
||||
#define EMS_TYPE_JunkersStatusMessage 0x6F // is an automatic thermostat broadcast giving us temps
|
||||
|
||||