Add features to WW messages (0x33, 0x34) to improve WW monitoring.
This commit is contained in:
15
src/ems.cpp
15
src/ems.cpp
@@ -145,6 +145,8 @@ void ems_init() {
|
||||
EMS_Boiler.wWActivated = EMS_VALUE_BOOL_NOTSET; // Warm Water activated
|
||||
EMS_Boiler.wWSelTemp = EMS_VALUE_INT_NOTSET; // Warm Water selected temperature
|
||||
EMS_Boiler.wWCircPump = EMS_VALUE_BOOL_NOTSET; // Warm Water circulation pump available
|
||||
EMS_Boiler.wWCircPumpMode = EMS_VALUE_INT_NOTSET; // Warm Water circulation pump mode
|
||||
EMS_Boiler.wWCircPumpType = EMS_VALUE_BOOL_NOTSET; // Warm Water circulation pump mode
|
||||
EMS_Boiler.wWDesinfectTemp = EMS_VALUE_INT_NOTSET; // Warm Water desinfection temperature to prevent infection
|
||||
EMS_Boiler.wWComfort = EMS_VALUE_INT_NOTSET; // WW comfort mode
|
||||
|
||||
@@ -182,6 +184,11 @@ void ems_init() {
|
||||
EMS_Boiler.wWStarts = EMS_VALUE_LONG_NOTSET; // Warm Water # starts
|
||||
EMS_Boiler.wWWorkM = EMS_VALUE_LONG_NOTSET; // Warm Water # minutes
|
||||
EMS_Boiler.wWOneTime = EMS_VALUE_INT_NOTSET; // Warm Water one time function on/off
|
||||
EMS_Boiler.wWDesinfecting = EMS_VALUE_INT_NOTSET; // Warm Water desinfection on/off
|
||||
EMS_Boiler.wWReadiness = EMS_VALUE_INT_NOTSET; // Warm Water readiness on/off
|
||||
EMS_Boiler.wWRecharging = EMS_VALUE_INT_NOTSET; // Warm Water recharge on/off
|
||||
EMS_Boiler.wWTemperaturOK = EMS_VALUE_INT_NOTSET; // Warm Water temperatur ok on/off
|
||||
|
||||
EMS_Boiler.wWCurFlow = EMS_VALUE_INT_NOTSET; // WW current flow temp
|
||||
|
||||
// UBATotalUptimeMessage
|
||||
@@ -927,7 +934,7 @@ void _removeTxQueue() {
|
||||
|
||||
/**
|
||||
* Check if hot tap water or heating is active
|
||||
* using a quick hack for checking the heating. Selected Flow Temp >= 70
|
||||
* using a quick hack for checking the heating. Selected Flow Temp >= 30
|
||||
*/
|
||||
void _checkActive() {
|
||||
// hot tap water, using flow to check instead of the burner power
|
||||
@@ -948,6 +955,8 @@ void _checkActive() {
|
||||
void _process_UBAParameterWW(_EMS_RxTelegram * EMS_RxTelegram) {
|
||||
_setValue(EMS_RxTelegram, &EMS_Boiler.wWActivated, 1); // 0xFF means on
|
||||
_setValue(EMS_RxTelegram, &EMS_Boiler.wWCircPump, 6); // 0xFF means on
|
||||
_setValue(EMS_RxTelegram, &EMS_Boiler.wWCircPumpMode, 7); // 1=1x3min... 6=6x3min, 7=continuous
|
||||
_setValue(EMS_RxTelegram, &EMS_Boiler.wWCircPumpType, 10); // 0 = charge pump, 0xff = 3-way valve
|
||||
_setValue(EMS_RxTelegram, &EMS_Boiler.wWSelTemp, 2);
|
||||
_setValue(EMS_RxTelegram, &EMS_Boiler.wWDesinfectTemp, 8);
|
||||
_setValue(EMS_RxTelegram, &EMS_Boiler.wWComfort, EMS_OFFSET_UBAParameterWW_wwComfort);
|
||||
@@ -979,6 +988,10 @@ void _process_UBAMonitorWWMessage(_EMS_RxTelegram * EMS_RxTelegram) {
|
||||
_setValue(EMS_RxTelegram, &EMS_Boiler.wWStarts, 13);
|
||||
_setValue(EMS_RxTelegram, &EMS_Boiler.wWWorkM, 10);
|
||||
_setValue(EMS_RxTelegram, &EMS_Boiler.wWOneTime, 5, 1);
|
||||
_setValue(EMS_RxTelegram, &EMS_Boiler.wWDesinfecting, 5, 2);
|
||||
_setValue(EMS_RxTelegram, &EMS_Boiler.wWReadiness, 5, 3);
|
||||
_setValue(EMS_RxTelegram, &EMS_Boiler.wWRecharging, 5, 4);
|
||||
_setValue(EMS_RxTelegram, &EMS_Boiler.wWTemperaturOK, 5, 5);
|
||||
_setValue(EMS_RxTelegram, &EMS_Boiler.wWCurFlow, 9);
|
||||
}
|
||||
|
||||
|
||||