mirror of
https://github.com/emsesp/EMS-ESP32.git
synced 2025-12-06 15:59:52 +03:00
3.6.3
This commit is contained in:
37
CHANGELOG.md
37
CHANGELOG.md
@@ -5,6 +5,43 @@ All notable changes to this project will be documented in this file.
|
||||
The format is based on [Keep a Changelog](https://keepachangelog.com/en/1.0.0/),
|
||||
and this project adheres to [Semantic Versioning](https://semver.org/spec/v2.0.0.html).
|
||||
|
||||
## [3.6.3] November 18 2023
|
||||
|
||||
## **IMPORTANT! BREAKING CHANGES**
|
||||
|
||||
Writeable Text entities have moved from type `sensor` to `text` in Home Assistant to make them also editable within an HA dashboard. Examples are `datetime`, `holidays`, `switchtime`, `vacations`, `maintenancedate`. You will need to manually remove any old discovery topics from your MQTT broker using an application like MQTT Explorer.
|
||||
|
||||
## Added
|
||||
|
||||
- humidity for ventilation devices
|
||||
- telegrams for RC100H, hc2, etc. (seen on discord, not tested)
|
||||
- names for BC400, GB192i.2, read temperatures for low loss header and heatblock [#1317](https://github.com/emsesp/EMS-ESP32/discussions/1317)
|
||||
- option for `forceheatingoff` [#1262](https://github.com/emsesp/EMS-ESP32/issues/1262)
|
||||
- remote thermostat emulation RC100H for RC3xx [#1278](https://github.com/emsesp/EMS-ESP32/discussions/1278)
|
||||
- shower_data MQTT payload contains the timestamp [#1329](https://github.com/emsesp/EMS-ESP32/issues/1329)
|
||||
- HA discovery for writeable text entities [#1337](https://github.com/emsesp/EMS-ESP32/pull/1377)
|
||||
- autodetect board_profile, store in nvs, add telnet command option, add E32V2
|
||||
- heat pump high res energy counters [#1348, #1349. #1350](https://github.com/emsesp/EMS-ESP32/issues/1348)
|
||||
- optional bssid in network settings
|
||||
- extension module EM100 [#1315](https://github.com/emsesp/EMS-ESP32/discussions/1315)
|
||||
- digital_out with new options for polarity and startup state
|
||||
- added 'system allvalues' command that dumps all the EMS device values, plus sensors and any custom entities
|
||||
|
||||
## Fixed
|
||||
|
||||
- remove command `remoteseltemp`, thermostat accept it only from remote thermostat
|
||||
- shower_data MQTT payload contains the timestamp [#1329](https://github.com/emsesp/EMS-ESP32/issues/1329)
|
||||
- fixed helper text in Web Device Entity dialog box for numerical ranges
|
||||
- MQTT base with paths not working in HA [#1393](https://github.com/emsesp/EMS-ESP32/issues/1393)
|
||||
|
||||
## Changed
|
||||
|
||||
- update to platform 6.4.0, arduino 2.0.14 / idf 4.4.6
|
||||
- small changes for arduino 3.0.0 / idf 5.1 compatibility (not backward compatible to platform 6.3.2 and before)
|
||||
- AP start after 10 sec, stay until station/eth connected
|
||||
- tested wifi-all-channel-scan (3.6.3-dev4 a-e), removed again because of connect issues
|
||||
- mqtt disconnect stops queue
|
||||
|
||||
## [3.6.2] October 1 2023
|
||||
|
||||
## **IMPORTANT! BREAKING CHANGES**
|
||||
|
||||
@@ -1,38 +1 @@
|
||||
# Changelog
|
||||
|
||||
## [3.6.3]
|
||||
|
||||
## **IMPORTANT! BREAKING CHANGES**
|
||||
|
||||
Writeable Text entities have moved from type `sensor` to `text` in Home Assistant to make them also editable within an HA dashboard. Examples are `datetime`, `holidays`, `switchtime`, `vacations`, `maintenancedate`... You will need to manually remove any old discovery topics from your MQTT broker using an application like MQTT Explorer.
|
||||
|
||||
## Added
|
||||
|
||||
- humidity for ventilation devices
|
||||
- telegrams for RC100H, hc2, etc. (seen on discord, not tested)
|
||||
- names for BC400, GB192i.2, read temperatures for low loss header and heatblock [#1317](https://github.com/emsesp/EMS-ESP32/discussions/1317)
|
||||
- option for `forceheatingoff` [#1262](https://github.com/emsesp/EMS-ESP32/issues/1262)
|
||||
- remote thermostat emulation RC100H for RC3xx [#1278](https://github.com/emsesp/EMS-ESP32/discussions/1278)
|
||||
- shower_data MQTT payload contains the timestamp [#1329](https://github.com/emsesp/EMS-ESP32/issues/1329)
|
||||
- HA discovery for writeable text entities [#1337](https://github.com/emsesp/EMS-ESP32/pull/1377)
|
||||
- autodetect board_profile, store in nvs, add telnet command option, add E32V2
|
||||
- heat pump high res energy counters [#1348, #1349. #1350](https://github.com/emsesp/EMS-ESP32/issues/1348)
|
||||
- optional bssid in network settings
|
||||
- extension module EM100 [#1315](https://github.com/emsesp/EMS-ESP32/discussions/1315)
|
||||
- digital_out with new options for polarity and startup state
|
||||
- added 'system allvalues' command that dumps all the EMS device values, plus sensors and any custom entities
|
||||
|
||||
## Fixed
|
||||
|
||||
- remove command `remoteseltemp`, thermostat accept it only from remote thermostat
|
||||
- shower_data MQTT payload contains the timestamp [#1329](https://github.com/emsesp/EMS-ESP32/issues/1329)
|
||||
- fixed helper text in Web Device Entity dialog box for numerical ranges
|
||||
- MQTT base with paths not working in HA [#1393](https://github.com/emsesp/EMS-ESP32/issues/1393)
|
||||
|
||||
## Changed
|
||||
|
||||
- update to platform 6.4.0, arduino 2.0.14 / idf 4.4.6
|
||||
- small changes for arduino 3.0.0 / idf 5.1 compatibility (not backward compatible to platform 6.3.2 and before)
|
||||
- AP start after 10 sec, stay until station/eth connected
|
||||
- tested wifi-all-channel-scan (3.6.3-dev4 a-e), removed again because of connect issues
|
||||
- mqtt disconnect stops queue
|
||||
|
||||
File diff suppressed because it is too large
Load Diff
Reference in New Issue
Block a user