New Entity: Cooling status for free cooling

Fixes #3097
This commit is contained in:
proddy
2026-10-13 22:40:09 +02:00
parent 8693d27a02
commit 68d7f6e444
3 changed files with 20 additions and 1 deletions
+1
View File
@@ -31,6 +31,7 @@ This release is based on the latest Espressif/Arduino core version 3. It brings
## Fixed
- heat-pump operating state (`hpoperatingstate`: heating/off/cooling) is published for every heating circuit. On BC400/UI800 it was only filled for hc1, because hc2 never answers telegram 0x472 while the state is still broadcast in 0x2A6 offset 20 [#3097](https://github.com/emsesp/EMS-ESP32/issues/3097)
- restart from the WebUI (Restart button, firmware/settings upload) only happened while the browser tab stayed open. If the tab was closed the restart was silently dropped after 5 minutes, leaving a new firmware uninstalled. EMS-ESP now restarts on its own if the WebUI hasn't picked up the pending restart within 10 seconds
- shunting yard show json
- `system/sendmail` called from a Command or the Scheduler computed its value twice, which stripped the quotes from literal text and then failed on characters like `!`. Also shunting yard treated a `?` inside a quoted string as a ternary, so text like `"too hot?"` returned nothing