mirror of
https://github.com/emsesp/EMS-ESP32.git
synced 2025-12-10 09:49:54 +03:00
formatting
This commit is contained in:
@@ -54,16 +54,20 @@
|
||||
|
||||
#define EMS_OFFSET_UBASetPoints_flowtemp 0 // flow temp
|
||||
|
||||
// SM and HP Types
|
||||
// Solar Module
|
||||
// Assuming here that the SM200 behaves like SM100
|
||||
#define EMS_TYPE_SM10Monitor 0x97 // SM10Monitor
|
||||
#define EMS_TYPE_SM100Monitor 0x0262 // SM100Monitor
|
||||
#define EMS_TYPE_SM100Status 0x0264 // SM100Status
|
||||
#define EMS_TYPE_SM100Status2 0x026A // SM100Status2
|
||||
#define EMS_TYPE_SM100Energy 0x028E // SM100Energy
|
||||
#define EMS_TYPE_HPMonitor1 0xE3 // HeatPump Monitor 1
|
||||
#define EMS_TYPE_HPMonitor2 0xE5 // HeatPump Monitor 2
|
||||
|
||||
// Heat Pump
|
||||
#define EMS_TYPE_HPMonitor1 0xE3 // HeatPump Monitor 1
|
||||
#define EMS_TYPE_HPMonitor2 0xE5 // HeatPump Monitor 2
|
||||
|
||||
|
||||
// ISPM solar module
|
||||
#define EMS_TYPE_ISM1StatusMessage 0x0003 // Solar Module Junkers ISM1 Status
|
||||
#define EMS_TYPE_ISM1Set 0x0001 // for setting values of the solar module like max boiler temp
|
||||
#define EMS_OFFSET_ISM1Set_MaxBoilerTemp 6 // position of max boiler temp e.g. 50 in the following example: 90 30 FF 06 00 01 50 (CRC=2C)
|
||||
@@ -171,16 +175,16 @@
|
||||
#define EMS_OFFSET_JunkersSetMessage_no_frost_temp 0x0F // EMS offset to set temperature on thermostat for no frost mode
|
||||
#define EMS_OFFSET_JunkersSetMessage_set_mode 0x0E // EMS offset to set mode on thermostat
|
||||
|
||||
// MM100 (EMS Plus)
|
||||
#define EMS_TYPE_MMPLUSStatusMessage_HC1 0x01D7 // mixer status HC1
|
||||
#define EMS_TYPE_MMPLUSStatusMessage_HC2 0x01D8 // mixer status HC2
|
||||
#define EMS_TYPE_MMPLUSStatusMessage_HC3 0x01D9 // mixer status HC3
|
||||
#define EMS_TYPE_MMPLUSStatusMessage_HC4 0x01DA // mixer status HC4
|
||||
#define EMS_TYPE_MMPLUSStatusMessage_WWC1 0x0231 // mixer status WWC1
|
||||
#define EMS_TYPE_MMPLUSStatusMessage_WWC2 0x0232 // mixer status WWC2
|
||||
#define EMS_OFFSET_MMPLUSStatusMessage_flow_temp 3 // flow temperature
|
||||
#define EMS_OFFSET_MMPLUSStatusMessage_pump_mod 5 // pump modulation
|
||||
#define EMS_OFFSET_MMPLUSStatusMessage_valve_status 2 // valve in percent
|
||||
// MM100/MM200 (EMS Plus)
|
||||
#define EMS_TYPE_MMPLUSStatusMessage_HC1 0x01D7 // mixer status HC1
|
||||
#define EMS_TYPE_MMPLUSStatusMessage_HC2 0x01D8 // mixer status HC2
|
||||
#define EMS_TYPE_MMPLUSStatusMessage_HC3 0x01D9 // mixer status HC3
|
||||
#define EMS_TYPE_MMPLUSStatusMessage_HC4 0x01DA // mixer status HC4
|
||||
#define EMS_TYPE_MMPLUSStatusMessage_WWC1 0x0231 // mixer status WWC1
|
||||
#define EMS_TYPE_MMPLUSStatusMessage_WWC2 0x0232 // mixer status WWC2
|
||||
#define EMS_OFFSET_MMPLUSStatusMessage_flow_temp 3 // flow temperature
|
||||
#define EMS_OFFSET_MMPLUSStatusMessage_pump_mod 5 // pump modulation
|
||||
#define EMS_OFFSET_MMPLUSStatusMessage_valve_status 2 // valve in percent
|
||||
#define EMS_OFFSET_MMPLUSStatusMessage_WW_flow_temp 0 // flow temperature
|
||||
#define EMS_OFFSET_MMPLUSStatusMessage_WW_pump_mod 2 // pump on 6, off 0
|
||||
#define EMS_OFFSET_MMPLUSStatusMessage_WW_temp_status 11 // 0,1,2
|
||||
|
||||
Reference in New Issue
Block a user