diff --git a/docs/Modbus-Entity-Registers.md b/docs/Modbus-Entity-Registers.md index 07571758e..e68fba989 100644 --- a/docs/Modbus-Entity-Registers.md +++ b/docs/Modbus-Entity-Registers.md @@ -90,9 +90,9 @@ | meterheat | meter heating | uint24 (>=0<=1677721) | kWh | false | DEVICE_DATA | 95 | 2 | 1/10 | | dhw.meter | meter | uint24 (>=0<=1677721) | kWh | false | DHW | 2 | 2 | 1/10 | | gasmeterheat | gas meter heating | uint24 (>=0<=1677721) | kWh | false | DEVICE_DATA | 266 | 2 | 1/10 | -| dhw.gasmeter | gas meter | uint24 (>=0<=1677721) | kWh | false | DHW | 69 | 2 | 1/10 | +| dhw.gasmeter | gas meter | uint24 (>=0<=1677721) | kWh | false | DHW | 70 | 2 | 1/10 | | nrgheat2 | energy heating 2 | uint24 (>=0<=1677721) | kWh | false | DEVICE_DATA | 268 | 2 | 1/10 | -| dhw.nrg2 | energy 2 | uint24 (>=0<=1677721) | kWh | false | DHW | 71 | 2 | 1/10 | +| dhw.nrg2 | energy 2 | uint24 (>=0<=1677721) | kWh | false | DHW | 72 | 2 | 1/10 | | dhw.tapactivated | turn on/off | boolean | | true | DHW | 28 | 1 | 1 | | dhw.settemp | set temperature | uint8 (>=0<=254) | C | false | DHW | 29 | 1 | 1 | | dhw.seltemp | selected temperature | uint8 (>=0<=254) | C | true | DHW | 30 | 1 | 1 | @@ -128,10 +128,11 @@ | dhw.tempok | temperature ok | boolean | | false | DHW | 60 | 1 | 1 | | dhw.active | active | boolean | | false | DHW | 61 | 1 | 1 | | dhw.3wayvalve | 3-way valve active | boolean | | false | DHW | 62 | 1 | 1 | -| dhw.mixertemp | mixer temperature | uint16 (>=0<=3199) | C | false | DHW | 63 | 1 | 1/10 | -| dhw.cylmiddletemp | cylinder middle temperature (TS3) | uint16 (>=0<=3199) | C | false | DHW | 64 | 1 | 1/10 | -| dhw.starts | starts | uint24 (>=0<=16777214) | | false | DHW | 65 | 2 | 1 | -| dhw.workm | active time | time (>=0<=16777214) | minutes | false | DHW | 67 | 2 | 1 | +| dhw.chargepump | charge pump | boolean | | false | DHW | 63 | 1 | 1 | +| dhw.mixertemp | mixer temperature | uint16 (>=0<=3199) | C | false | DHW | 64 | 1 | 1/10 | +| dhw.cylmiddletemp | cylinder middle temperature (TS3) | uint16 (>=0<=3199) | C | false | DHW | 65 | 1 | 1/10 | +| dhw.starts | starts | uint24 (>=0<=16777214) | | false | DHW | 66 | 2 | 1 | +| dhw.workm | active time | time (>=0<=16777214) | minutes | false | DHW | 68 | 2 | 1 | | nompower | nominal Power | uint8 (>=0<=254) | kW | true | DEVICE_DATA | 270 | 1 | 1 | | nrgtotal | total energy | uint24 (>=0<=167772) | kWh | false | DEVICE_DATA | 83 | 2 | 1/100 | | nrgheat | energy heating | uint24 (>=0<=10000000) | kWh | true | DEVICE_DATA | 85 | 2 | 1/100 | @@ -208,9 +209,9 @@ | meterheat | meter heating | uint24 (>=0<=1677721) | kWh | false | DEVICE_DATA | 95 | 2 | 1/10 | | dhw.meter | meter | uint24 (>=0<=1677721) | kWh | false | DHW | 2 | 2 | 1/10 | | gasmeterheat | gas meter heating | uint24 (>=0<=1677721) | kWh | false | DEVICE_DATA | 266 | 2 | 1/10 | -| dhw.gasmeter | gas meter | uint24 (>=0<=1677721) | kWh | false | DHW | 69 | 2 | 1/10 | +| dhw.gasmeter | gas meter | uint24 (>=0<=1677721) | kWh | false | DHW | 70 | 2 | 1/10 | | nrgheat2 | energy heating 2 | uint24 (>=0<=1677721) | kWh | false | DEVICE_DATA | 268 | 2 | 1/10 | -| dhw.nrg2 | energy 2 | uint24 (>=0<=1677721) | kWh | false | DHW | 71 | 2 | 1/10 | +| dhw.nrg2 | energy 2 | uint24 (>=0<=1677721) | kWh | false | DHW | 72 | 2 | 1/10 | | dhw.tapactivated | turn on/off | boolean | | true | DHW | 28 | 1 | 1 | | dhw.settemp | set temperature | uint8 (>=0<=254) | C | false | DHW | 29 | 1 | 1 | | dhw.seltemp | selected temperature | uint8 (>=0<=254) | C | true | DHW | 30 | 1 | 1 | @@ -246,16 +247,17 @@ | dhw.tempok | temperature ok | boolean | | false | DHW | 60 | 1 | 1 | | dhw.active | active | boolean | | false | DHW | 61 | 1 | 1 | | dhw.3wayvalve | 3-way valve active | boolean | | false | DHW | 62 | 1 | 1 | -| dhw.mixertemp | mixer temperature | uint16 (>=0<=3199) | C | false | DHW | 63 | 1 | 1/10 | -| dhw.cylmiddletemp | cylinder middle temperature (TS3) | uint16 (>=0<=3199) | C | false | DHW | 64 | 1 | 1/10 | -| dhw.starts | starts | uint24 (>=0<=16777214) | | false | DHW | 65 | 2 | 1 | -| dhw.workm | active time | time (>=0<=16777214) | minutes | false | DHW | 67 | 2 | 1 | +| dhw.chargepump | charge pump | boolean | | false | DHW | 63 | 1 | 1 | +| dhw.mixertemp | mixer temperature | uint16 (>=0<=3199) | C | false | DHW | 64 | 1 | 1/10 | +| dhw.cylmiddletemp | cylinder middle temperature (TS3) | uint16 (>=0<=3199) | C | false | DHW | 65 | 1 | 1/10 | +| dhw.starts | starts | uint24 (>=0<=16777214) | | false | DHW | 66 | 2 | 1 | +| dhw.workm | active time | time (>=0<=16777214) | minutes | false | DHW | 68 | 2 | 1 | | nompower | nominal Power | uint8 (>=0<=254) | kW | true | DEVICE_DATA | 270 | 1 | 1 | | nrgtotal | total energy | uint24 (>=0<=167772) | kWh | false | DEVICE_DATA | 83 | 2 | 1/100 | | nrgheat | energy heating | uint24 (>=0<=10000000) | kWh | true | DEVICE_DATA | 85 | 2 | 1/100 | | dhw.nrg | energy | uint24 (>=0<=10000000) | kWh | true | DHW | 0 | 2 | 1/100 | -### CS*800i, Logatherm WLW* +### CS5800i, CS6800i, WLW176i, WLW186i | shortname | fullname | type | uom | writeable | tag type | register offset | register count | scale factor | |-|-|-|-|-|-|-|-|-| | reset | reset | cmd [-\|maintenance\|error\|history\|message] | | true | DEVICE_DATA | 0 | 1 | 1 | @@ -374,9 +376,9 @@ | hpin3opt | input 3 options | string | | true | DEVICE_DATA | 189 | 8 | 1 | | hpin4 | input 4 state | boolean | | false | DEVICE_DATA | 197 | 1 | 1 | | hpin4opt | input 4 options | string | | true | DEVICE_DATA | 198 | 8 | 1 | -| maxheatcomp | heat limit compressor | enum [0 kW\|2 kW\|3 kW\|4 kW\|6 kW\|9 kW] | | true | DEVICE_DATA | 206 | 1 | 1 | -| maxheatheat | heat limit heating | enum [0 kW\|2 kW\|3 kW\|4 kW\|6 kW\|9 kW] | | true | DEVICE_DATA | 207 | 1 | 1 | -| dhw.maxheat | heat limit | enum [0 kW\|2 kW\|3 kW\|4 kW\|6 kW\|9 kW] | | true | DHW | 14 | 1 | 1 | +| maxheatcomp | heat limit compressor | enum [0 kW\|3 kW\|6 kW\|9 kW] | | true | DEVICE_DATA | 206 | 1 | 1 | +| maxheatheat | heat limit heating | enum [3 kW\|6 kW\|9 kW] | | true | DEVICE_DATA | 207 | 1 | 1 | +| dhw.maxheat | heat limit | enum [3 kW\|6 kW\|9 kW] | | true | DHW | 14 | 1 | 1 | | auxheatersource | aux heater source | enum [not installed\|electric heater\|exclusive\|parallel\|hybrid] | | true | DEVICE_DATA | 208 | 1 | 1 | | pvcooling | cooling only with PV | boolean | | true | DEVICE_DATA | 209 | 1 | 1 | | auxheateronly | aux heater only | boolean | | true | DEVICE_DATA | 210 | 1 | 1 | @@ -461,10 +463,11 @@ | dhw.tempok | temperature ok | boolean | | false | DHW | 60 | 1 | 1 | | dhw.active | active | boolean | | false | DHW | 61 | 1 | 1 | | dhw.3wayvalve | 3-way valve active | boolean | | false | DHW | 62 | 1 | 1 | -| dhw.mixertemp | mixer temperature | uint16 (>=0<=3199) | C | false | DHW | 63 | 1 | 1/10 | -| dhw.cylmiddletemp | cylinder middle temperature (TS3) | uint16 (>=0<=3199) | C | false | DHW | 64 | 1 | 1/10 | -| dhw.starts | starts | uint24 (>=0<=16777214) | | false | DHW | 65 | 2 | 1 | -| dhw.workm | active time | time (>=0<=16777214) | minutes | false | DHW | 67 | 2 | 1 | +| dhw.chargepump | charge pump | boolean | | false | DHW | 63 | 1 | 1 | +| dhw.mixertemp | mixer temperature | uint16 (>=0<=3199) | C | false | DHW | 64 | 1 | 1/10 | +| dhw.cylmiddletemp | cylinder middle temperature (TS3) | uint16 (>=0<=3199) | C | false | DHW | 65 | 1 | 1/10 | +| dhw.starts | starts | uint24 (>=0<=16777214) | | false | DHW | 66 | 2 | 1 | +| dhw.workm | active time | time (>=0<=16777214) | minutes | false | DHW | 68 | 2 | 1 | ### Cascade CM10 | shortname | fullname | type | uom | writeable | tag type | register offset | register count | scale factor | @@ -537,9 +540,9 @@ | meterheat | meter heating | uint24 (>=0<=1677721) | kWh | false | DEVICE_DATA | 95 | 2 | 1/10 | | dhw.meter | meter | uint24 (>=0<=1677721) | kWh | false | DHW | 2 | 2 | 1/10 | | gasmeterheat | gas meter heating | uint24 (>=0<=1677721) | kWh | false | DEVICE_DATA | 266 | 2 | 1/10 | -| dhw.gasmeter | gas meter | uint24 (>=0<=1677721) | kWh | false | DHW | 69 | 2 | 1/10 | +| dhw.gasmeter | gas meter | uint24 (>=0<=1677721) | kWh | false | DHW | 70 | 2 | 1/10 | | nrgheat2 | energy heating 2 | uint24 (>=0<=1677721) | kWh | false | DEVICE_DATA | 268 | 2 | 1/10 | -| dhw.nrg2 | energy 2 | uint24 (>=0<=1677721) | kWh | false | DHW | 71 | 2 | 1/10 | +| dhw.nrg2 | energy 2 | uint24 (>=0<=1677721) | kWh | false | DHW | 72 | 2 | 1/10 | | dhw.tapactivated | turn on/off | boolean | | true | DHW | 28 | 1 | 1 | | dhw.settemp | set temperature | uint8 (>=0<=254) | C | false | DHW | 29 | 1 | 1 | | dhw.seltemp | selected temperature | uint8 (>=0<=254) | C | true | DHW | 30 | 1 | 1 | @@ -575,10 +578,11 @@ | dhw.tempok | temperature ok | boolean | | false | DHW | 60 | 1 | 1 | | dhw.active | active | boolean | | false | DHW | 61 | 1 | 1 | | dhw.3wayvalve | 3-way valve active | boolean | | false | DHW | 62 | 1 | 1 | -| dhw.mixertemp | mixer temperature | uint16 (>=0<=3199) | C | false | DHW | 63 | 1 | 1/10 | -| dhw.cylmiddletemp | cylinder middle temperature (TS3) | uint16 (>=0<=3199) | C | false | DHW | 64 | 1 | 1/10 | -| dhw.starts | starts | uint24 (>=0<=16777214) | | false | DHW | 65 | 2 | 1 | -| dhw.workm | active time | time (>=0<=16777214) | minutes | false | DHW | 67 | 2 | 1 | +| dhw.chargepump | charge pump | boolean | | false | DHW | 63 | 1 | 1 | +| dhw.mixertemp | mixer temperature | uint16 (>=0<=3199) | C | false | DHW | 64 | 1 | 1/10 | +| dhw.cylmiddletemp | cylinder middle temperature (TS3) | uint16 (>=0<=3199) | C | false | DHW | 65 | 1 | 1/10 | +| dhw.starts | starts | uint24 (>=0<=16777214) | | false | DHW | 66 | 2 | 1 | +| dhw.workm | active time | time (>=0<=16777214) | minutes | false | DHW | 68 | 2 | 1 | | nompower | nominal Power | uint8 (>=0<=254) | kW | true | DEVICE_DATA | 270 | 1 | 1 | | nrgtotal | total energy | uint24 (>=0<=167772) | kWh | false | DEVICE_DATA | 83 | 2 | 1/100 | | nrgheat | energy heating | uint24 (>=0<=10000000) | kWh | true | DEVICE_DATA | 85 | 2 | 1/100 | @@ -655,9 +659,9 @@ | meterheat | meter heating | uint24 (>=0<=1677721) | kWh | false | DEVICE_DATA | 95 | 2 | 1/10 | | dhw.meter | meter | uint24 (>=0<=1677721) | kWh | false | DHW | 2 | 2 | 1/10 | | gasmeterheat | gas meter heating | uint24 (>=0<=1677721) | kWh | false | DEVICE_DATA | 266 | 2 | 1/10 | -| dhw.gasmeter | gas meter | uint24 (>=0<=1677721) | kWh | false | DHW | 69 | 2 | 1/10 | +| dhw.gasmeter | gas meter | uint24 (>=0<=1677721) | kWh | false | DHW | 70 | 2 | 1/10 | | nrgheat2 | energy heating 2 | uint24 (>=0<=1677721) | kWh | false | DEVICE_DATA | 268 | 2 | 1/10 | -| dhw.nrg2 | energy 2 | uint24 (>=0<=1677721) | kWh | false | DHW | 71 | 2 | 1/10 | +| dhw.nrg2 | energy 2 | uint24 (>=0<=1677721) | kWh | false | DHW | 72 | 2 | 1/10 | | dhw.tapactivated | turn on/off | boolean | | true | DHW | 28 | 1 | 1 | | dhw.settemp | set temperature | uint8 (>=0<=254) | C | false | DHW | 29 | 1 | 1 | | dhw.seltemp | selected temperature | uint8 (>=0<=254) | C | true | DHW | 30 | 1 | 1 | @@ -693,10 +697,11 @@ | dhw.tempok | temperature ok | boolean | | false | DHW | 60 | 1 | 1 | | dhw.active | active | boolean | | false | DHW | 61 | 1 | 1 | | dhw.3wayvalve | 3-way valve active | boolean | | false | DHW | 62 | 1 | 1 | -| dhw.mixertemp | mixer temperature | uint16 (>=0<=3199) | C | false | DHW | 63 | 1 | 1/10 | -| dhw.cylmiddletemp | cylinder middle temperature (TS3) | uint16 (>=0<=3199) | C | false | DHW | 64 | 1 | 1/10 | -| dhw.starts | starts | uint24 (>=0<=16777214) | | false | DHW | 65 | 2 | 1 | -| dhw.workm | active time | time (>=0<=16777214) | minutes | false | DHW | 67 | 2 | 1 | +| dhw.chargepump | charge pump | boolean | | false | DHW | 63 | 1 | 1 | +| dhw.mixertemp | mixer temperature | uint16 (>=0<=3199) | C | false | DHW | 64 | 1 | 1/10 | +| dhw.cylmiddletemp | cylinder middle temperature (TS3) | uint16 (>=0<=3199) | C | false | DHW | 65 | 1 | 1/10 | +| dhw.starts | starts | uint24 (>=0<=16777214) | | false | DHW | 66 | 2 | 1 | +| dhw.workm | active time | time (>=0<=16777214) | minutes | false | DHW | 68 | 2 | 1 | | nompower | nominal Power | uint8 (>=0<=254) | kW | true | DEVICE_DATA | 270 | 1 | 1 | | nrgtotal | total energy | uint24 (>=0<=167772) | kWh | false | DEVICE_DATA | 83 | 2 | 1/100 | | nrgheat | energy heating | uint24 (>=0<=10000000) | kWh | true | DEVICE_DATA | 85 | 2 | 1/100 | @@ -773,9 +778,9 @@ | meterheat | meter heating | uint24 (>=0<=1677721) | kWh | false | DEVICE_DATA | 95 | 2 | 1/10 | | dhw.meter | meter | uint24 (>=0<=1677721) | kWh | false | DHW | 2 | 2 | 1/10 | | gasmeterheat | gas meter heating | uint24 (>=0<=1677721) | kWh | false | DEVICE_DATA | 266 | 2 | 1/10 | -| dhw.gasmeter | gas meter | uint24 (>=0<=1677721) | kWh | false | DHW | 69 | 2 | 1/10 | +| dhw.gasmeter | gas meter | uint24 (>=0<=1677721) | kWh | false | DHW | 70 | 2 | 1/10 | | nrgheat2 | energy heating 2 | uint24 (>=0<=1677721) | kWh | false | DEVICE_DATA | 268 | 2 | 1/10 | -| dhw.nrg2 | energy 2 | uint24 (>=0<=1677721) | kWh | false | DHW | 71 | 2 | 1/10 | +| dhw.nrg2 | energy 2 | uint24 (>=0<=1677721) | kWh | false | DHW | 72 | 2 | 1/10 | | dhw.tapactivated | turn on/off | boolean | | true | DHW | 28 | 1 | 1 | | dhw.settemp | set temperature | uint8 (>=0<=254) | C | false | DHW | 29 | 1 | 1 | | dhw.seltemp | selected temperature | uint8 (>=0<=254) | C | true | DHW | 30 | 1 | 1 | @@ -811,10 +816,11 @@ | dhw.tempok | temperature ok | boolean | | false | DHW | 60 | 1 | 1 | | dhw.active | active | boolean | | false | DHW | 61 | 1 | 1 | | dhw.3wayvalve | 3-way valve active | boolean | | false | DHW | 62 | 1 | 1 | -| dhw.mixertemp | mixer temperature | uint16 (>=0<=3199) | C | false | DHW | 63 | 1 | 1/10 | -| dhw.cylmiddletemp | cylinder middle temperature (TS3) | uint16 (>=0<=3199) | C | false | DHW | 64 | 1 | 1/10 | -| dhw.starts | starts | uint24 (>=0<=16777214) | | false | DHW | 65 | 2 | 1 | -| dhw.workm | active time | time (>=0<=16777214) | minutes | false | DHW | 67 | 2 | 1 | +| dhw.chargepump | charge pump | boolean | | false | DHW | 63 | 1 | 1 | +| dhw.mixertemp | mixer temperature | uint16 (>=0<=3199) | C | false | DHW | 64 | 1 | 1/10 | +| dhw.cylmiddletemp | cylinder middle temperature (TS3) | uint16 (>=0<=3199) | C | false | DHW | 65 | 1 | 1/10 | +| dhw.starts | starts | uint24 (>=0<=16777214) | | false | DHW | 66 | 2 | 1 | +| dhw.workm | active time | time (>=0<=16777214) | minutes | false | DHW | 68 | 2 | 1 | | nompower | nominal Power | uint8 (>=0<=254) | kW | true | DEVICE_DATA | 270 | 1 | 1 | | nrgtotal | total energy | uint24 (>=0<=167772) | kWh | false | DEVICE_DATA | 83 | 2 | 1/100 | | nrgheat | energy heating | uint24 (>=0<=10000000) | kWh | true | DEVICE_DATA | 85 | 2 | 1/100 | @@ -891,9 +897,9 @@ | meterheat | meter heating | uint24 (>=0<=1677721) | kWh | false | DEVICE_DATA | 95 | 2 | 1/10 | | dhw.meter | meter | uint24 (>=0<=1677721) | kWh | false | DHW | 2 | 2 | 1/10 | | gasmeterheat | gas meter heating | uint24 (>=0<=1677721) | kWh | false | DEVICE_DATA | 266 | 2 | 1/10 | -| dhw.gasmeter | gas meter | uint24 (>=0<=1677721) | kWh | false | DHW | 69 | 2 | 1/10 | +| dhw.gasmeter | gas meter | uint24 (>=0<=1677721) | kWh | false | DHW | 70 | 2 | 1/10 | | nrgheat2 | energy heating 2 | uint24 (>=0<=1677721) | kWh | false | DEVICE_DATA | 268 | 2 | 1/10 | -| dhw.nrg2 | energy 2 | uint24 (>=0<=1677721) | kWh | false | DHW | 71 | 2 | 1/10 | +| dhw.nrg2 | energy 2 | uint24 (>=0<=1677721) | kWh | false | DHW | 72 | 2 | 1/10 | | dhw.tapactivated | turn on/off | boolean | | true | DHW | 28 | 1 | 1 | | dhw.settemp | set temperature | uint8 (>=0<=254) | C | false | DHW | 29 | 1 | 1 | | dhw.seltemp | selected temperature | uint8 (>=0<=254) | C | true | DHW | 30 | 1 | 1 | @@ -929,10 +935,11 @@ | dhw.tempok | temperature ok | boolean | | false | DHW | 60 | 1 | 1 | | dhw.active | active | boolean | | false | DHW | 61 | 1 | 1 | | dhw.3wayvalve | 3-way valve active | boolean | | false | DHW | 62 | 1 | 1 | -| dhw.mixertemp | mixer temperature | uint16 (>=0<=3199) | C | false | DHW | 63 | 1 | 1/10 | -| dhw.cylmiddletemp | cylinder middle temperature (TS3) | uint16 (>=0<=3199) | C | false | DHW | 64 | 1 | 1/10 | -| dhw.starts | starts | uint24 (>=0<=16777214) | | false | DHW | 65 | 2 | 1 | -| dhw.workm | active time | time (>=0<=16777214) | minutes | false | DHW | 67 | 2 | 1 | +| dhw.chargepump | charge pump | boolean | | false | DHW | 63 | 1 | 1 | +| dhw.mixertemp | mixer temperature | uint16 (>=0<=3199) | C | false | DHW | 64 | 1 | 1/10 | +| dhw.cylmiddletemp | cylinder middle temperature (TS3) | uint16 (>=0<=3199) | C | false | DHW | 65 | 1 | 1/10 | +| dhw.starts | starts | uint24 (>=0<=16777214) | | false | DHW | 66 | 2 | 1 | +| dhw.workm | active time | time (>=0<=16777214) | minutes | false | DHW | 68 | 2 | 1 | | nompower | nominal Power | uint8 (>=0<=254) | kW | true | DEVICE_DATA | 270 | 1 | 1 | | nrgtotal | total energy | uint24 (>=0<=167772) | kWh | false | DEVICE_DATA | 83 | 2 | 1/100 | | nrgheat | energy heating | uint24 (>=0<=10000000) | kWh | true | DEVICE_DATA | 85 | 2 | 1/100 | @@ -1009,9 +1016,9 @@ | meterheat | meter heating | uint24 (>=0<=1677721) | kWh | false | DEVICE_DATA | 95 | 2 | 1/10 | | dhw.meter | meter | uint24 (>=0<=1677721) | kWh | false | DHW | 2 | 2 | 1/10 | | gasmeterheat | gas meter heating | uint24 (>=0<=1677721) | kWh | false | DEVICE_DATA | 266 | 2 | 1/10 | -| dhw.gasmeter | gas meter | uint24 (>=0<=1677721) | kWh | false | DHW | 69 | 2 | 1/10 | +| dhw.gasmeter | gas meter | uint24 (>=0<=1677721) | kWh | false | DHW | 70 | 2 | 1/10 | | nrgheat2 | energy heating 2 | uint24 (>=0<=1677721) | kWh | false | DEVICE_DATA | 268 | 2 | 1/10 | -| dhw.nrg2 | energy 2 | uint24 (>=0<=1677721) | kWh | false | DHW | 71 | 2 | 1/10 | +| dhw.nrg2 | energy 2 | uint24 (>=0<=1677721) | kWh | false | DHW | 72 | 2 | 1/10 | | dhw.tapactivated | turn on/off | boolean | | true | DHW | 28 | 1 | 1 | | dhw.settemp | set temperature | uint8 (>=0<=254) | C | false | DHW | 29 | 1 | 1 | | dhw.seltemp | selected temperature | uint8 (>=0<=254) | C | true | DHW | 30 | 1 | 1 | @@ -1047,10 +1054,11 @@ | dhw.tempok | temperature ok | boolean | | false | DHW | 60 | 1 | 1 | | dhw.active | active | boolean | | false | DHW | 61 | 1 | 1 | | dhw.3wayvalve | 3-way valve active | boolean | | false | DHW | 62 | 1 | 1 | -| dhw.mixertemp | mixer temperature | uint16 (>=0<=3199) | C | false | DHW | 63 | 1 | 1/10 | -| dhw.cylmiddletemp | cylinder middle temperature (TS3) | uint16 (>=0<=3199) | C | false | DHW | 64 | 1 | 1/10 | -| dhw.starts | starts | uint24 (>=0<=16777214) | | false | DHW | 65 | 2 | 1 | -| dhw.workm | active time | time (>=0<=16777214) | minutes | false | DHW | 67 | 2 | 1 | +| dhw.chargepump | charge pump | boolean | | false | DHW | 63 | 1 | 1 | +| dhw.mixertemp | mixer temperature | uint16 (>=0<=3199) | C | false | DHW | 64 | 1 | 1/10 | +| dhw.cylmiddletemp | cylinder middle temperature (TS3) | uint16 (>=0<=3199) | C | false | DHW | 65 | 1 | 1/10 | +| dhw.starts | starts | uint24 (>=0<=16777214) | | false | DHW | 66 | 2 | 1 | +| dhw.workm | active time | time (>=0<=16777214) | minutes | false | DHW | 68 | 2 | 1 | | nompower | nominal Power | uint8 (>=0<=254) | kW | true | DEVICE_DATA | 270 | 1 | 1 | | nrgtotal | total energy | uint24 (>=0<=167772) | kWh | false | DEVICE_DATA | 83 | 2 | 1/100 | | nrgheat | energy heating | uint24 (>=0<=10000000) | kWh | true | DEVICE_DATA | 85 | 2 | 1/100 | @@ -1127,9 +1135,9 @@ | meterheat | meter heating | uint24 (>=0<=1677721) | kWh | false | DEVICE_DATA | 95 | 2 | 1/10 | | dhw.meter | meter | uint24 (>=0<=1677721) | kWh | false | DHW | 2 | 2 | 1/10 | | gasmeterheat | gas meter heating | uint24 (>=0<=1677721) | kWh | false | DEVICE_DATA | 266 | 2 | 1/10 | -| dhw.gasmeter | gas meter | uint24 (>=0<=1677721) | kWh | false | DHW | 69 | 2 | 1/10 | +| dhw.gasmeter | gas meter | uint24 (>=0<=1677721) | kWh | false | DHW | 70 | 2 | 1/10 | | nrgheat2 | energy heating 2 | uint24 (>=0<=1677721) | kWh | false | DEVICE_DATA | 268 | 2 | 1/10 | -| dhw.nrg2 | energy 2 | uint24 (>=0<=1677721) | kWh | false | DHW | 71 | 2 | 1/10 | +| dhw.nrg2 | energy 2 | uint24 (>=0<=1677721) | kWh | false | DHW | 72 | 2 | 1/10 | | dhw.tapactivated | turn on/off | boolean | | true | DHW | 28 | 1 | 1 | | dhw.settemp | set temperature | uint8 (>=0<=254) | C | false | DHW | 29 | 1 | 1 | | dhw.seltemp | selected temperature | uint8 (>=0<=254) | C | true | DHW | 30 | 1 | 1 | @@ -1165,10 +1173,11 @@ | dhw.tempok | temperature ok | boolean | | false | DHW | 60 | 1 | 1 | | dhw.active | active | boolean | | false | DHW | 61 | 1 | 1 | | dhw.3wayvalve | 3-way valve active | boolean | | false | DHW | 62 | 1 | 1 | -| dhw.mixertemp | mixer temperature | uint16 (>=0<=3199) | C | false | DHW | 63 | 1 | 1/10 | -| dhw.cylmiddletemp | cylinder middle temperature (TS3) | uint16 (>=0<=3199) | C | false | DHW | 64 | 1 | 1/10 | -| dhw.starts | starts | uint24 (>=0<=16777214) | | false | DHW | 65 | 2 | 1 | -| dhw.workm | active time | time (>=0<=16777214) | minutes | false | DHW | 67 | 2 | 1 | +| dhw.chargepump | charge pump | boolean | | false | DHW | 63 | 1 | 1 | +| dhw.mixertemp | mixer temperature | uint16 (>=0<=3199) | C | false | DHW | 64 | 1 | 1/10 | +| dhw.cylmiddletemp | cylinder middle temperature (TS3) | uint16 (>=0<=3199) | C | false | DHW | 65 | 1 | 1/10 | +| dhw.starts | starts | uint24 (>=0<=16777214) | | false | DHW | 66 | 2 | 1 | +| dhw.workm | active time | time (>=0<=16777214) | minutes | false | DHW | 68 | 2 | 1 | | nompower | nominal Power | uint8 (>=0<=254) | kW | true | DEVICE_DATA | 270 | 1 | 1 | | nrgtotal | total energy | uint24 (>=0<=167772) | kWh | false | DEVICE_DATA | 83 | 2 | 1/100 | | nrgheat | energy heating | uint24 (>=0<=10000000) | kWh | true | DEVICE_DATA | 85 | 2 | 1/100 | @@ -1245,9 +1254,9 @@ | meterheat | meter heating | uint24 (>=0<=1677721) | kWh | false | DEVICE_DATA | 95 | 2 | 1/10 | | dhw.meter | meter | uint24 (>=0<=1677721) | kWh | false | DHW | 2 | 2 | 1/10 | | gasmeterheat | gas meter heating | uint24 (>=0<=1677721) | kWh | false | DEVICE_DATA | 266 | 2 | 1/10 | -| dhw.gasmeter | gas meter | uint24 (>=0<=1677721) | kWh | false | DHW | 69 | 2 | 1/10 | +| dhw.gasmeter | gas meter | uint24 (>=0<=1677721) | kWh | false | DHW | 70 | 2 | 1/10 | | nrgheat2 | energy heating 2 | uint24 (>=0<=1677721) | kWh | false | DEVICE_DATA | 268 | 2 | 1/10 | -| dhw.nrg2 | energy 2 | uint24 (>=0<=1677721) | kWh | false | DHW | 71 | 2 | 1/10 | +| dhw.nrg2 | energy 2 | uint24 (>=0<=1677721) | kWh | false | DHW | 72 | 2 | 1/10 | | dhw.tapactivated | turn on/off | boolean | | true | DHW | 28 | 1 | 1 | | dhw.settemp | set temperature | uint8 (>=0<=254) | C | false | DHW | 29 | 1 | 1 | | dhw.seltemp | selected temperature | uint8 (>=0<=254) | C | true | DHW | 30 | 1 | 1 | @@ -1283,10 +1292,11 @@ | dhw.tempok | temperature ok | boolean | | false | DHW | 60 | 1 | 1 | | dhw.active | active | boolean | | false | DHW | 61 | 1 | 1 | | dhw.3wayvalve | 3-way valve active | boolean | | false | DHW | 62 | 1 | 1 | -| dhw.mixertemp | mixer temperature | uint16 (>=0<=3199) | C | false | DHW | 63 | 1 | 1/10 | -| dhw.cylmiddletemp | cylinder middle temperature (TS3) | uint16 (>=0<=3199) | C | false | DHW | 64 | 1 | 1/10 | -| dhw.starts | starts | uint24 (>=0<=16777214) | | false | DHW | 65 | 2 | 1 | -| dhw.workm | active time | time (>=0<=16777214) | minutes | false | DHW | 67 | 2 | 1 | +| dhw.chargepump | charge pump | boolean | | false | DHW | 63 | 1 | 1 | +| dhw.mixertemp | mixer temperature | uint16 (>=0<=3199) | C | false | DHW | 64 | 1 | 1/10 | +| dhw.cylmiddletemp | cylinder middle temperature (TS3) | uint16 (>=0<=3199) | C | false | DHW | 65 | 1 | 1/10 | +| dhw.starts | starts | uint24 (>=0<=16777214) | | false | DHW | 66 | 2 | 1 | +| dhw.workm | active time | time (>=0<=16777214) | minutes | false | DHW | 68 | 2 | 1 | | nompower | nominal Power | uint8 (>=0<=254) | kW | true | DEVICE_DATA | 270 | 1 | 1 | | nrgtotal | total energy | uint24 (>=0<=167772) | kWh | false | DEVICE_DATA | 83 | 2 | 1/100 | | nrgheat | energy heating | uint24 (>=0<=10000000) | kWh | true | DEVICE_DATA | 85 | 2 | 1/100 | @@ -1363,9 +1373,9 @@ | meterheat | meter heating | uint24 (>=0<=1677721) | kWh | false | DEVICE_DATA | 95 | 2 | 1/10 | | dhw.meter | meter | uint24 (>=0<=1677721) | kWh | false | DHW | 2 | 2 | 1/10 | | gasmeterheat | gas meter heating | uint24 (>=0<=1677721) | kWh | false | DEVICE_DATA | 266 | 2 | 1/10 | -| dhw.gasmeter | gas meter | uint24 (>=0<=1677721) | kWh | false | DHW | 69 | 2 | 1/10 | +| dhw.gasmeter | gas meter | uint24 (>=0<=1677721) | kWh | false | DHW | 70 | 2 | 1/10 | | nrgheat2 | energy heating 2 | uint24 (>=0<=1677721) | kWh | false | DEVICE_DATA | 268 | 2 | 1/10 | -| dhw.nrg2 | energy 2 | uint24 (>=0<=1677721) | kWh | false | DHW | 71 | 2 | 1/10 | +| dhw.nrg2 | energy 2 | uint24 (>=0<=1677721) | kWh | false | DHW | 72 | 2 | 1/10 | | dhw.tapactivated | turn on/off | boolean | | true | DHW | 28 | 1 | 1 | | dhw.settemp | set temperature | uint8 (>=0<=254) | C | false | DHW | 29 | 1 | 1 | | dhw.seltemp | selected temperature | uint8 (>=0<=254) | C | true | DHW | 30 | 1 | 1 | @@ -1401,10 +1411,11 @@ | dhw.tempok | temperature ok | boolean | | false | DHW | 60 | 1 | 1 | | dhw.active | active | boolean | | false | DHW | 61 | 1 | 1 | | dhw.3wayvalve | 3-way valve active | boolean | | false | DHW | 62 | 1 | 1 | -| dhw.mixertemp | mixer temperature | uint16 (>=0<=3199) | C | false | DHW | 63 | 1 | 1/10 | -| dhw.cylmiddletemp | cylinder middle temperature (TS3) | uint16 (>=0<=3199) | C | false | DHW | 64 | 1 | 1/10 | -| dhw.starts | starts | uint24 (>=0<=16777214) | | false | DHW | 65 | 2 | 1 | -| dhw.workm | active time | time (>=0<=16777214) | minutes | false | DHW | 67 | 2 | 1 | +| dhw.chargepump | charge pump | boolean | | false | DHW | 63 | 1 | 1 | +| dhw.mixertemp | mixer temperature | uint16 (>=0<=3199) | C | false | DHW | 64 | 1 | 1/10 | +| dhw.cylmiddletemp | cylinder middle temperature (TS3) | uint16 (>=0<=3199) | C | false | DHW | 65 | 1 | 1/10 | +| dhw.starts | starts | uint24 (>=0<=16777214) | | false | DHW | 66 | 2 | 1 | +| dhw.workm | active time | time (>=0<=16777214) | minutes | false | DHW | 68 | 2 | 1 | | nompower | nominal Power | uint8 (>=0<=254) | kW | true | DEVICE_DATA | 270 | 1 | 1 | | nrgtotal | total energy | uint24 (>=0<=167772) | kWh | false | DEVICE_DATA | 83 | 2 | 1/100 | | nrgheat | energy heating | uint24 (>=0<=10000000) | kWh | true | DEVICE_DATA | 85 | 2 | 1/100 | @@ -1616,10 +1627,11 @@ | dhw.tempok | temperature ok | boolean | | false | DHW | 60 | 1 | 1 | | dhw.active | active | boolean | | false | DHW | 61 | 1 | 1 | | dhw.3wayvalve | 3-way valve active | boolean | | false | DHW | 62 | 1 | 1 | -| dhw.mixertemp | mixer temperature | uint16 (>=0<=3199) | C | false | DHW | 63 | 1 | 1/10 | -| dhw.cylmiddletemp | cylinder middle temperature (TS3) | uint16 (>=0<=3199) | C | false | DHW | 64 | 1 | 1/10 | -| dhw.starts | starts | uint24 (>=0<=16777214) | | false | DHW | 65 | 2 | 1 | -| dhw.workm | active time | time (>=0<=16777214) | minutes | false | DHW | 67 | 2 | 1 | +| dhw.chargepump | charge pump | boolean | | false | DHW | 63 | 1 | 1 | +| dhw.mixertemp | mixer temperature | uint16 (>=0<=3199) | C | false | DHW | 64 | 1 | 1/10 | +| dhw.cylmiddletemp | cylinder middle temperature (TS3) | uint16 (>=0<=3199) | C | false | DHW | 65 | 1 | 1/10 | +| dhw.starts | starts | uint24 (>=0<=16777214) | | false | DHW | 66 | 2 | 1 | +| dhw.workm | active time | time (>=0<=16777214) | minutes | false | DHW | 68 | 2 | 1 | ### GB*72, Trendline, Cerapur, Greenstar Si | shortname | fullname | type | uom | writeable | tag type | register offset | register count | scale factor | @@ -1692,9 +1704,9 @@ | meterheat | meter heating | uint24 (>=0<=1677721) | kWh | false | DEVICE_DATA | 95 | 2 | 1/10 | | dhw.meter | meter | uint24 (>=0<=1677721) | kWh | false | DHW | 2 | 2 | 1/10 | | gasmeterheat | gas meter heating | uint24 (>=0<=1677721) | kWh | false | DEVICE_DATA | 266 | 2 | 1/10 | -| dhw.gasmeter | gas meter | uint24 (>=0<=1677721) | kWh | false | DHW | 69 | 2 | 1/10 | +| dhw.gasmeter | gas meter | uint24 (>=0<=1677721) | kWh | false | DHW | 70 | 2 | 1/10 | | nrgheat2 | energy heating 2 | uint24 (>=0<=1677721) | kWh | false | DEVICE_DATA | 268 | 2 | 1/10 | -| dhw.nrg2 | energy 2 | uint24 (>=0<=1677721) | kWh | false | DHW | 71 | 2 | 1/10 | +| dhw.nrg2 | energy 2 | uint24 (>=0<=1677721) | kWh | false | DHW | 72 | 2 | 1/10 | | dhw.tapactivated | turn on/off | boolean | | true | DHW | 28 | 1 | 1 | | dhw.settemp | set temperature | uint8 (>=0<=254) | C | false | DHW | 29 | 1 | 1 | | dhw.seltemp | selected temperature | uint8 (>=0<=254) | C | true | DHW | 30 | 1 | 1 | @@ -1730,10 +1742,11 @@ | dhw.tempok | temperature ok | boolean | | false | DHW | 60 | 1 | 1 | | dhw.active | active | boolean | | false | DHW | 61 | 1 | 1 | | dhw.3wayvalve | 3-way valve active | boolean | | false | DHW | 62 | 1 | 1 | -| dhw.mixertemp | mixer temperature | uint16 (>=0<=3199) | C | false | DHW | 63 | 1 | 1/10 | -| dhw.cylmiddletemp | cylinder middle temperature (TS3) | uint16 (>=0<=3199) | C | false | DHW | 64 | 1 | 1/10 | -| dhw.starts | starts | uint24 (>=0<=16777214) | | false | DHW | 65 | 2 | 1 | -| dhw.workm | active time | time (>=0<=16777214) | minutes | false | DHW | 67 | 2 | 1 | +| dhw.chargepump | charge pump | boolean | | false | DHW | 63 | 1 | 1 | +| dhw.mixertemp | mixer temperature | uint16 (>=0<=3199) | C | false | DHW | 64 | 1 | 1/10 | +| dhw.cylmiddletemp | cylinder middle temperature (TS3) | uint16 (>=0<=3199) | C | false | DHW | 65 | 1 | 1/10 | +| dhw.starts | starts | uint24 (>=0<=16777214) | | false | DHW | 66 | 2 | 1 | +| dhw.workm | active time | time (>=0<=16777214) | minutes | false | DHW | 68 | 2 | 1 | | nompower | nominal Power | uint8 (>=0<=254) | kW | true | DEVICE_DATA | 270 | 1 | 1 | | nrgtotal | total energy | uint24 (>=0<=167772) | kWh | false | DEVICE_DATA | 83 | 2 | 1/100 | | nrgheat | energy heating | uint24 (>=0<=10000000) | kWh | true | DEVICE_DATA | 85 | 2 | 1/100 | @@ -1810,9 +1823,9 @@ | meterheat | meter heating | uint24 (>=0<=1677721) | kWh | false | DEVICE_DATA | 95 | 2 | 1/10 | | dhw.meter | meter | uint24 (>=0<=1677721) | kWh | false | DHW | 2 | 2 | 1/10 | | gasmeterheat | gas meter heating | uint24 (>=0<=1677721) | kWh | false | DEVICE_DATA | 266 | 2 | 1/10 | -| dhw.gasmeter | gas meter | uint24 (>=0<=1677721) | kWh | false | DHW | 69 | 2 | 1/10 | +| dhw.gasmeter | gas meter | uint24 (>=0<=1677721) | kWh | false | DHW | 70 | 2 | 1/10 | | nrgheat2 | energy heating 2 | uint24 (>=0<=1677721) | kWh | false | DEVICE_DATA | 268 | 2 | 1/10 | -| dhw.nrg2 | energy 2 | uint24 (>=0<=1677721) | kWh | false | DHW | 71 | 2 | 1/10 | +| dhw.nrg2 | energy 2 | uint24 (>=0<=1677721) | kWh | false | DHW | 72 | 2 | 1/10 | | dhw.tapactivated | turn on/off | boolean | | true | DHW | 28 | 1 | 1 | | dhw.settemp | set temperature | uint8 (>=0<=254) | C | false | DHW | 29 | 1 | 1 | | dhw.seltemp | selected temperature | uint8 (>=0<=254) | C | true | DHW | 30 | 1 | 1 | @@ -1848,10 +1861,11 @@ | dhw.tempok | temperature ok | boolean | | false | DHW | 60 | 1 | 1 | | dhw.active | active | boolean | | false | DHW | 61 | 1 | 1 | | dhw.3wayvalve | 3-way valve active | boolean | | false | DHW | 62 | 1 | 1 | -| dhw.mixertemp | mixer temperature | uint16 (>=0<=3199) | C | false | DHW | 63 | 1 | 1/10 | -| dhw.cylmiddletemp | cylinder middle temperature (TS3) | uint16 (>=0<=3199) | C | false | DHW | 64 | 1 | 1/10 | -| dhw.starts | starts | uint24 (>=0<=16777214) | | false | DHW | 65 | 2 | 1 | -| dhw.workm | active time | time (>=0<=16777214) | minutes | false | DHW | 67 | 2 | 1 | +| dhw.chargepump | charge pump | boolean | | false | DHW | 63 | 1 | 1 | +| dhw.mixertemp | mixer temperature | uint16 (>=0<=3199) | C | false | DHW | 64 | 1 | 1/10 | +| dhw.cylmiddletemp | cylinder middle temperature (TS3) | uint16 (>=0<=3199) | C | false | DHW | 65 | 1 | 1/10 | +| dhw.starts | starts | uint24 (>=0<=16777214) | | false | DHW | 66 | 2 | 1 | +| dhw.workm | active time | time (>=0<=16777214) | minutes | false | DHW | 68 | 2 | 1 | | nompower | nominal Power | uint8 (>=0<=254) | kW | true | DEVICE_DATA | 270 | 1 | 1 | | nrgtotal | total energy | uint24 (>=0<=167772) | kWh | false | DEVICE_DATA | 83 | 2 | 1/100 | | nrgheat | energy heating | uint24 (>=0<=10000000) | kWh | true | DEVICE_DATA | 85 | 2 | 1/100 | @@ -1928,9 +1942,9 @@ | meterheat | meter heating | uint24 (>=0<=1677721) | kWh | false | DEVICE_DATA | 95 | 2 | 1/10 | | dhw.meter | meter | uint24 (>=0<=1677721) | kWh | false | DHW | 2 | 2 | 1/10 | | gasmeterheat | gas meter heating | uint24 (>=0<=1677721) | kWh | false | DEVICE_DATA | 266 | 2 | 1/10 | -| dhw.gasmeter | gas meter | uint24 (>=0<=1677721) | kWh | false | DHW | 69 | 2 | 1/10 | +| dhw.gasmeter | gas meter | uint24 (>=0<=1677721) | kWh | false | DHW | 70 | 2 | 1/10 | | nrgheat2 | energy heating 2 | uint24 (>=0<=1677721) | kWh | false | DEVICE_DATA | 268 | 2 | 1/10 | -| dhw.nrg2 | energy 2 | uint24 (>=0<=1677721) | kWh | false | DHW | 71 | 2 | 1/10 | +| dhw.nrg2 | energy 2 | uint24 (>=0<=1677721) | kWh | false | DHW | 72 | 2 | 1/10 | | dhw.tapactivated | turn on/off | boolean | | true | DHW | 28 | 1 | 1 | | dhw.settemp | set temperature | uint8 (>=0<=254) | C | false | DHW | 29 | 1 | 1 | | dhw.seltemp | selected temperature | uint8 (>=0<=254) | C | true | DHW | 30 | 1 | 1 | @@ -1966,10 +1980,11 @@ | dhw.tempok | temperature ok | boolean | | false | DHW | 60 | 1 | 1 | | dhw.active | active | boolean | | false | DHW | 61 | 1 | 1 | | dhw.3wayvalve | 3-way valve active | boolean | | false | DHW | 62 | 1 | 1 | -| dhw.mixertemp | mixer temperature | uint16 (>=0<=3199) | C | false | DHW | 63 | 1 | 1/10 | -| dhw.cylmiddletemp | cylinder middle temperature (TS3) | uint16 (>=0<=3199) | C | false | DHW | 64 | 1 | 1/10 | -| dhw.starts | starts | uint24 (>=0<=16777214) | | false | DHW | 65 | 2 | 1 | -| dhw.workm | active time | time (>=0<=16777214) | minutes | false | DHW | 67 | 2 | 1 | +| dhw.chargepump | charge pump | boolean | | false | DHW | 63 | 1 | 1 | +| dhw.mixertemp | mixer temperature | uint16 (>=0<=3199) | C | false | DHW | 64 | 1 | 1/10 | +| dhw.cylmiddletemp | cylinder middle temperature (TS3) | uint16 (>=0<=3199) | C | false | DHW | 65 | 1 | 1/10 | +| dhw.starts | starts | uint24 (>=0<=16777214) | | false | DHW | 66 | 2 | 1 | +| dhw.workm | active time | time (>=0<=16777214) | minutes | false | DHW | 68 | 2 | 1 | | nompower | nominal Power | uint8 (>=0<=254) | kW | true | DEVICE_DATA | 270 | 1 | 1 | | nrgtotal | total energy | uint24 (>=0<=167772) | kWh | false | DEVICE_DATA | 83 | 2 | 1/100 | | nrgheat | energy heating | uint24 (>=0<=10000000) | kWh | true | DEVICE_DATA | 85 | 2 | 1/100 | @@ -2181,10 +2196,11 @@ | dhw.tempok | temperature ok | boolean | | false | DHW | 60 | 1 | 1 | | dhw.active | active | boolean | | false | DHW | 61 | 1 | 1 | | dhw.3wayvalve | 3-way valve active | boolean | | false | DHW | 62 | 1 | 1 | -| dhw.mixertemp | mixer temperature | uint16 (>=0<=3199) | C | false | DHW | 63 | 1 | 1/10 | -| dhw.cylmiddletemp | cylinder middle temperature (TS3) | uint16 (>=0<=3199) | C | false | DHW | 64 | 1 | 1/10 | -| dhw.starts | starts | uint24 (>=0<=16777214) | | false | DHW | 65 | 2 | 1 | -| dhw.workm | active time | time (>=0<=16777214) | minutes | false | DHW | 67 | 2 | 1 | +| dhw.chargepump | charge pump | boolean | | false | DHW | 63 | 1 | 1 | +| dhw.mixertemp | mixer temperature | uint16 (>=0<=3199) | C | false | DHW | 64 | 1 | 1/10 | +| dhw.cylmiddletemp | cylinder middle temperature (TS3) | uint16 (>=0<=3199) | C | false | DHW | 65 | 1 | 1/10 | +| dhw.starts | starts | uint24 (>=0<=16777214) | | false | DHW | 66 | 2 | 1 | +| dhw.workm | active time | time (>=0<=16777214) | minutes | false | DHW | 68 | 2 | 1 | ### Greenstar 30Ri Compact | shortname | fullname | type | uom | writeable | tag type | register offset | register count | scale factor | @@ -2257,9 +2273,9 @@ | meterheat | meter heating | uint24 (>=0<=1677721) | kWh | false | DEVICE_DATA | 95 | 2 | 1/10 | | dhw.meter | meter | uint24 (>=0<=1677721) | kWh | false | DHW | 2 | 2 | 1/10 | | gasmeterheat | gas meter heating | uint24 (>=0<=1677721) | kWh | false | DEVICE_DATA | 266 | 2 | 1/10 | -| dhw.gasmeter | gas meter | uint24 (>=0<=1677721) | kWh | false | DHW | 69 | 2 | 1/10 | +| dhw.gasmeter | gas meter | uint24 (>=0<=1677721) | kWh | false | DHW | 70 | 2 | 1/10 | | nrgheat2 | energy heating 2 | uint24 (>=0<=1677721) | kWh | false | DEVICE_DATA | 268 | 2 | 1/10 | -| dhw.nrg2 | energy 2 | uint24 (>=0<=1677721) | kWh | false | DHW | 71 | 2 | 1/10 | +| dhw.nrg2 | energy 2 | uint24 (>=0<=1677721) | kWh | false | DHW | 72 | 2 | 1/10 | | dhw.tapactivated | turn on/off | boolean | | true | DHW | 28 | 1 | 1 | | dhw.settemp | set temperature | uint8 (>=0<=254) | C | false | DHW | 29 | 1 | 1 | | dhw.seltemp | selected temperature | uint8 (>=0<=254) | C | true | DHW | 30 | 1 | 1 | @@ -2295,10 +2311,11 @@ | dhw.tempok | temperature ok | boolean | | false | DHW | 60 | 1 | 1 | | dhw.active | active | boolean | | false | DHW | 61 | 1 | 1 | | dhw.3wayvalve | 3-way valve active | boolean | | false | DHW | 62 | 1 | 1 | -| dhw.mixertemp | mixer temperature | uint16 (>=0<=3199) | C | false | DHW | 63 | 1 | 1/10 | -| dhw.cylmiddletemp | cylinder middle temperature (TS3) | uint16 (>=0<=3199) | C | false | DHW | 64 | 1 | 1/10 | -| dhw.starts | starts | uint24 (>=0<=16777214) | | false | DHW | 65 | 2 | 1 | -| dhw.workm | active time | time (>=0<=16777214) | minutes | false | DHW | 67 | 2 | 1 | +| dhw.chargepump | charge pump | boolean | | false | DHW | 63 | 1 | 1 | +| dhw.mixertemp | mixer temperature | uint16 (>=0<=3199) | C | false | DHW | 64 | 1 | 1/10 | +| dhw.cylmiddletemp | cylinder middle temperature (TS3) | uint16 (>=0<=3199) | C | false | DHW | 65 | 1 | 1/10 | +| dhw.starts | starts | uint24 (>=0<=16777214) | | false | DHW | 66 | 2 | 1 | +| dhw.workm | active time | time (>=0<=16777214) | minutes | false | DHW | 68 | 2 | 1 | | nompower | nominal Power | uint8 (>=0<=254) | kW | true | DEVICE_DATA | 270 | 1 | 1 | | nrgtotal | total energy | uint24 (>=0<=167772) | kWh | false | DEVICE_DATA | 83 | 2 | 1/100 | | nrgheat | energy heating | uint24 (>=0<=10000000) | kWh | true | DEVICE_DATA | 85 | 2 | 1/100 | @@ -2309,7 +2326,7 @@ |-|-|-|-|-|-|-|-|-| | netflowtemp | heat network flow temp | uint16 (>=0<=3199) | C | false | DEVICE_DATA | 271 | 1 | 1/10 | | heatvalve | heating valve | uint8 (>=0<=100) | % | false | DEVICE_DATA | 272 | 1 | 1 | -| dhw.dhwvalve | valve | uint8 (>=0<=100) | % | false | DHW | 73 | 1 | 1 | +| dhw.dhwvalve | valve | uint8 (>=0<=100) | % | false | DHW | 74 | 1 | 1 | | keepwarmtemp | keep warm temperature | uint8 (>=0<=254) | C | true | DEVICE_DATA | 273 | 1 | 1 | | setreturntemp | set temp return | uint8 (>=0<=254) | C | true | DEVICE_DATA | 274 | 1 | 1 | | heating | heating | boolean | | false | DEVICE_DATA | 275 | 1 | 1 | @@ -2359,9 +2376,9 @@ | meterheat | meter heating | uint24 (>=0<=1677721) | kWh | false | DEVICE_DATA | 95 | 2 | 1/10 | | dhw.meter | meter | uint24 (>=0<=1677721) | kWh | false | DHW | 2 | 2 | 1/10 | | gasmeterheat | gas meter heating | uint24 (>=0<=1677721) | kWh | false | DEVICE_DATA | 266 | 2 | 1/10 | -| dhw.gasmeter | gas meter | uint24 (>=0<=1677721) | kWh | false | DHW | 69 | 2 | 1/10 | +| dhw.gasmeter | gas meter | uint24 (>=0<=1677721) | kWh | false | DHW | 70 | 2 | 1/10 | | nrgheat2 | energy heating 2 | uint24 (>=0<=1677721) | kWh | false | DEVICE_DATA | 268 | 2 | 1/10 | -| dhw.nrg2 | energy 2 | uint24 (>=0<=1677721) | kWh | false | DHW | 71 | 2 | 1/10 | +| dhw.nrg2 | energy 2 | uint24 (>=0<=1677721) | kWh | false | DHW | 72 | 2 | 1/10 | | dhw.tapactivated | turn on/off | boolean | | true | DHW | 28 | 1 | 1 | | dhw.settemp | set temperature | uint8 (>=0<=254) | C | false | DHW | 29 | 1 | 1 | | dhw.seltemp | selected temperature | uint8 (>=0<=254) | C | true | DHW | 30 | 1 | 1 | @@ -2397,10 +2414,11 @@ | dhw.tempok | temperature ok | boolean | | false | DHW | 60 | 1 | 1 | | dhw.active | active | boolean | | false | DHW | 61 | 1 | 1 | | dhw.3wayvalve | 3-way valve active | boolean | | false | DHW | 62 | 1 | 1 | -| dhw.mixertemp | mixer temperature | uint16 (>=0<=3199) | C | false | DHW | 63 | 1 | 1/10 | -| dhw.cylmiddletemp | cylinder middle temperature (TS3) | uint16 (>=0<=3199) | C | false | DHW | 64 | 1 | 1/10 | -| dhw.starts | starts | uint24 (>=0<=16777214) | | false | DHW | 65 | 2 | 1 | -| dhw.workm | active time | time (>=0<=16777214) | minutes | false | DHW | 67 | 2 | 1 | +| dhw.chargepump | charge pump | boolean | | false | DHW | 63 | 1 | 1 | +| dhw.mixertemp | mixer temperature | uint16 (>=0<=3199) | C | false | DHW | 64 | 1 | 1/10 | +| dhw.cylmiddletemp | cylinder middle temperature (TS3) | uint16 (>=0<=3199) | C | false | DHW | 65 | 1 | 1/10 | +| dhw.starts | starts | uint24 (>=0<=16777214) | | false | DHW | 66 | 2 | 1 | +| dhw.workm | active time | time (>=0<=16777214) | minutes | false | DHW | 68 | 2 | 1 | ### Hybrid Heatpump | shortname | fullname | type | uom | writeable | tag type | register offset | register count | scale factor | @@ -2473,9 +2491,9 @@ | meterheat | meter heating | uint24 (>=0<=1677721) | kWh | false | DEVICE_DATA | 95 | 2 | 1/10 | | dhw.meter | meter | uint24 (>=0<=1677721) | kWh | false | DHW | 2 | 2 | 1/10 | | gasmeterheat | gas meter heating | uint24 (>=0<=1677721) | kWh | false | DEVICE_DATA | 266 | 2 | 1/10 | -| dhw.gasmeter | gas meter | uint24 (>=0<=1677721) | kWh | false | DHW | 69 | 2 | 1/10 | +| dhw.gasmeter | gas meter | uint24 (>=0<=1677721) | kWh | false | DHW | 70 | 2 | 1/10 | | nrgheat2 | energy heating 2 | uint24 (>=0<=1677721) | kWh | false | DEVICE_DATA | 268 | 2 | 1/10 | -| dhw.nrg2 | energy 2 | uint24 (>=0<=1677721) | kWh | false | DHW | 71 | 2 | 1/10 | +| dhw.nrg2 | energy 2 | uint24 (>=0<=1677721) | kWh | false | DHW | 72 | 2 | 1/10 | | dhw.tapactivated | turn on/off | boolean | | true | DHW | 28 | 1 | 1 | | dhw.settemp | set temperature | uint8 (>=0<=254) | C | false | DHW | 29 | 1 | 1 | | dhw.seltemp | selected temperature | uint8 (>=0<=254) | C | true | DHW | 30 | 1 | 1 | @@ -2511,10 +2529,11 @@ | dhw.tempok | temperature ok | boolean | | false | DHW | 60 | 1 | 1 | | dhw.active | active | boolean | | false | DHW | 61 | 1 | 1 | | dhw.3wayvalve | 3-way valve active | boolean | | false | DHW | 62 | 1 | 1 | -| dhw.mixertemp | mixer temperature | uint16 (>=0<=3199) | C | false | DHW | 63 | 1 | 1/10 | -| dhw.cylmiddletemp | cylinder middle temperature (TS3) | uint16 (>=0<=3199) | C | false | DHW | 64 | 1 | 1/10 | -| dhw.starts | starts | uint24 (>=0<=16777214) | | false | DHW | 65 | 2 | 1 | -| dhw.workm | active time | time (>=0<=16777214) | minutes | false | DHW | 67 | 2 | 1 | +| dhw.chargepump | charge pump | boolean | | false | DHW | 63 | 1 | 1 | +| dhw.mixertemp | mixer temperature | uint16 (>=0<=3199) | C | false | DHW | 64 | 1 | 1/10 | +| dhw.cylmiddletemp | cylinder middle temperature (TS3) | uint16 (>=0<=3199) | C | false | DHW | 65 | 1 | 1/10 | +| dhw.starts | starts | uint24 (>=0<=16777214) | | false | DHW | 66 | 2 | 1 | +| dhw.workm | active time | time (>=0<=16777214) | minutes | false | DHW | 68 | 2 | 1 | | nompower | nominal Power | uint8 (>=0<=254) | kW | true | DEVICE_DATA | 270 | 1 | 1 | | nrgtotal | total energy | uint24 (>=0<=167772) | kWh | false | DEVICE_DATA | 83 | 2 | 1/100 | | nrgheat | energy heating | uint24 (>=0<=10000000) | kWh | true | DEVICE_DATA | 85 | 2 | 1/100 | @@ -2591,9 +2610,9 @@ | meterheat | meter heating | uint24 (>=0<=1677721) | kWh | false | DEVICE_DATA | 95 | 2 | 1/10 | | dhw.meter | meter | uint24 (>=0<=1677721) | kWh | false | DHW | 2 | 2 | 1/10 | | gasmeterheat | gas meter heating | uint24 (>=0<=1677721) | kWh | false | DEVICE_DATA | 266 | 2 | 1/10 | -| dhw.gasmeter | gas meter | uint24 (>=0<=1677721) | kWh | false | DHW | 69 | 2 | 1/10 | +| dhw.gasmeter | gas meter | uint24 (>=0<=1677721) | kWh | false | DHW | 70 | 2 | 1/10 | | nrgheat2 | energy heating 2 | uint24 (>=0<=1677721) | kWh | false | DEVICE_DATA | 268 | 2 | 1/10 | -| dhw.nrg2 | energy 2 | uint24 (>=0<=1677721) | kWh | false | DHW | 71 | 2 | 1/10 | +| dhw.nrg2 | energy 2 | uint24 (>=0<=1677721) | kWh | false | DHW | 72 | 2 | 1/10 | | dhw.tapactivated | turn on/off | boolean | | true | DHW | 28 | 1 | 1 | | dhw.settemp | set temperature | uint8 (>=0<=254) | C | false | DHW | 29 | 1 | 1 | | dhw.seltemp | selected temperature | uint8 (>=0<=254) | C | true | DHW | 30 | 1 | 1 | @@ -2629,10 +2648,11 @@ | dhw.tempok | temperature ok | boolean | | false | DHW | 60 | 1 | 1 | | dhw.active | active | boolean | | false | DHW | 61 | 1 | 1 | | dhw.3wayvalve | 3-way valve active | boolean | | false | DHW | 62 | 1 | 1 | -| dhw.mixertemp | mixer temperature | uint16 (>=0<=3199) | C | false | DHW | 63 | 1 | 1/10 | -| dhw.cylmiddletemp | cylinder middle temperature (TS3) | uint16 (>=0<=3199) | C | false | DHW | 64 | 1 | 1/10 | -| dhw.starts | starts | uint24 (>=0<=16777214) | | false | DHW | 65 | 2 | 1 | -| dhw.workm | active time | time (>=0<=16777214) | minutes | false | DHW | 67 | 2 | 1 | +| dhw.chargepump | charge pump | boolean | | false | DHW | 63 | 1 | 1 | +| dhw.mixertemp | mixer temperature | uint16 (>=0<=3199) | C | false | DHW | 64 | 1 | 1/10 | +| dhw.cylmiddletemp | cylinder middle temperature (TS3) | uint16 (>=0<=3199) | C | false | DHW | 65 | 1 | 1/10 | +| dhw.starts | starts | uint24 (>=0<=16777214) | | false | DHW | 66 | 2 | 1 | +| dhw.workm | active time | time (>=0<=16777214) | minutes | false | DHW | 68 | 2 | 1 | | nompower | nominal Power | uint8 (>=0<=254) | kW | true | DEVICE_DATA | 270 | 1 | 1 | | nrgtotal | total energy | uint24 (>=0<=167772) | kWh | false | DEVICE_DATA | 83 | 2 | 1/100 | | nrgheat | energy heating | uint24 (>=0<=10000000) | kWh | true | DEVICE_DATA | 85 | 2 | 1/100 | @@ -2709,9 +2729,9 @@ | meterheat | meter heating | uint24 (>=0<=1677721) | kWh | false | DEVICE_DATA | 95 | 2 | 1/10 | | dhw.meter | meter | uint24 (>=0<=1677721) | kWh | false | DHW | 2 | 2 | 1/10 | | gasmeterheat | gas meter heating | uint24 (>=0<=1677721) | kWh | false | DEVICE_DATA | 266 | 2 | 1/10 | -| dhw.gasmeter | gas meter | uint24 (>=0<=1677721) | kWh | false | DHW | 69 | 2 | 1/10 | +| dhw.gasmeter | gas meter | uint24 (>=0<=1677721) | kWh | false | DHW | 70 | 2 | 1/10 | | nrgheat2 | energy heating 2 | uint24 (>=0<=1677721) | kWh | false | DEVICE_DATA | 268 | 2 | 1/10 | -| dhw.nrg2 | energy 2 | uint24 (>=0<=1677721) | kWh | false | DHW | 71 | 2 | 1/10 | +| dhw.nrg2 | energy 2 | uint24 (>=0<=1677721) | kWh | false | DHW | 72 | 2 | 1/10 | | dhw.tapactivated | turn on/off | boolean | | true | DHW | 28 | 1 | 1 | | dhw.settemp | set temperature | uint8 (>=0<=254) | C | false | DHW | 29 | 1 | 1 | | dhw.seltemp | selected temperature | uint8 (>=0<=254) | C | true | DHW | 30 | 1 | 1 | @@ -2747,10 +2767,11 @@ | dhw.tempok | temperature ok | boolean | | false | DHW | 60 | 1 | 1 | | dhw.active | active | boolean | | false | DHW | 61 | 1 | 1 | | dhw.3wayvalve | 3-way valve active | boolean | | false | DHW | 62 | 1 | 1 | -| dhw.mixertemp | mixer temperature | uint16 (>=0<=3199) | C | false | DHW | 63 | 1 | 1/10 | -| dhw.cylmiddletemp | cylinder middle temperature (TS3) | uint16 (>=0<=3199) | C | false | DHW | 64 | 1 | 1/10 | -| dhw.starts | starts | uint24 (>=0<=16777214) | | false | DHW | 65 | 2 | 1 | -| dhw.workm | active time | time (>=0<=16777214) | minutes | false | DHW | 67 | 2 | 1 | +| dhw.chargepump | charge pump | boolean | | false | DHW | 63 | 1 | 1 | +| dhw.mixertemp | mixer temperature | uint16 (>=0<=3199) | C | false | DHW | 64 | 1 | 1/10 | +| dhw.cylmiddletemp | cylinder middle temperature (TS3) | uint16 (>=0<=3199) | C | false | DHW | 65 | 1 | 1/10 | +| dhw.starts | starts | uint24 (>=0<=16777214) | | false | DHW | 66 | 2 | 1 | +| dhw.workm | active time | time (>=0<=16777214) | minutes | false | DHW | 68 | 2 | 1 | | nompower | nominal Power | uint8 (>=0<=254) | kW | true | DEVICE_DATA | 270 | 1 | 1 | | nrgtotal | total energy | uint24 (>=0<=167772) | kWh | false | DEVICE_DATA | 83 | 2 | 1/100 | | nrgheat | energy heating | uint24 (>=0<=10000000) | kWh | true | DEVICE_DATA | 85 | 2 | 1/100 | @@ -2827,9 +2848,9 @@ | meterheat | meter heating | uint24 (>=0<=1677721) | kWh | false | DEVICE_DATA | 95 | 2 | 1/10 | | dhw.meter | meter | uint24 (>=0<=1677721) | kWh | false | DHW | 2 | 2 | 1/10 | | gasmeterheat | gas meter heating | uint24 (>=0<=1677721) | kWh | false | DEVICE_DATA | 266 | 2 | 1/10 | -| dhw.gasmeter | gas meter | uint24 (>=0<=1677721) | kWh | false | DHW | 69 | 2 | 1/10 | +| dhw.gasmeter | gas meter | uint24 (>=0<=1677721) | kWh | false | DHW | 70 | 2 | 1/10 | | nrgheat2 | energy heating 2 | uint24 (>=0<=1677721) | kWh | false | DEVICE_DATA | 268 | 2 | 1/10 | -| dhw.nrg2 | energy 2 | uint24 (>=0<=1677721) | kWh | false | DHW | 71 | 2 | 1/10 | +| dhw.nrg2 | energy 2 | uint24 (>=0<=1677721) | kWh | false | DHW | 72 | 2 | 1/10 | | dhw.tapactivated | turn on/off | boolean | | true | DHW | 28 | 1 | 1 | | dhw.settemp | set temperature | uint8 (>=0<=254) | C | false | DHW | 29 | 1 | 1 | | dhw.seltemp | selected temperature | uint8 (>=0<=254) | C | true | DHW | 30 | 1 | 1 | @@ -2865,10 +2886,11 @@ | dhw.tempok | temperature ok | boolean | | false | DHW | 60 | 1 | 1 | | dhw.active | active | boolean | | false | DHW | 61 | 1 | 1 | | dhw.3wayvalve | 3-way valve active | boolean | | false | DHW | 62 | 1 | 1 | -| dhw.mixertemp | mixer temperature | uint16 (>=0<=3199) | C | false | DHW | 63 | 1 | 1/10 | -| dhw.cylmiddletemp | cylinder middle temperature (TS3) | uint16 (>=0<=3199) | C | false | DHW | 64 | 1 | 1/10 | -| dhw.starts | starts | uint24 (>=0<=16777214) | | false | DHW | 65 | 2 | 1 | -| dhw.workm | active time | time (>=0<=16777214) | minutes | false | DHW | 67 | 2 | 1 | +| dhw.chargepump | charge pump | boolean | | false | DHW | 63 | 1 | 1 | +| dhw.mixertemp | mixer temperature | uint16 (>=0<=3199) | C | false | DHW | 64 | 1 | 1/10 | +| dhw.cylmiddletemp | cylinder middle temperature (TS3) | uint16 (>=0<=3199) | C | false | DHW | 65 | 1 | 1/10 | +| dhw.starts | starts | uint24 (>=0<=16777214) | | false | DHW | 66 | 2 | 1 | +| dhw.workm | active time | time (>=0<=16777214) | minutes | false | DHW | 68 | 2 | 1 | | nompower | nominal Power | uint8 (>=0<=254) | kW | true | DEVICE_DATA | 270 | 1 | 1 | | nrgtotal | total energy | uint24 (>=0<=167772) | kWh | false | DEVICE_DATA | 83 | 2 | 1/100 | | nrgheat | energy heating | uint24 (>=0<=10000000) | kWh | true | DEVICE_DATA | 85 | 2 | 1/100 | @@ -2945,9 +2967,9 @@ | meterheat | meter heating | uint24 (>=0<=1677721) | kWh | false | DEVICE_DATA | 95 | 2 | 1/10 | | dhw.meter | meter | uint24 (>=0<=1677721) | kWh | false | DHW | 2 | 2 | 1/10 | | gasmeterheat | gas meter heating | uint24 (>=0<=1677721) | kWh | false | DEVICE_DATA | 266 | 2 | 1/10 | -| dhw.gasmeter | gas meter | uint24 (>=0<=1677721) | kWh | false | DHW | 69 | 2 | 1/10 | +| dhw.gasmeter | gas meter | uint24 (>=0<=1677721) | kWh | false | DHW | 70 | 2 | 1/10 | | nrgheat2 | energy heating 2 | uint24 (>=0<=1677721) | kWh | false | DEVICE_DATA | 268 | 2 | 1/10 | -| dhw.nrg2 | energy 2 | uint24 (>=0<=1677721) | kWh | false | DHW | 71 | 2 | 1/10 | +| dhw.nrg2 | energy 2 | uint24 (>=0<=1677721) | kWh | false | DHW | 72 | 2 | 1/10 | | dhw.tapactivated | turn on/off | boolean | | true | DHW | 28 | 1 | 1 | | dhw.settemp | set temperature | uint8 (>=0<=254) | C | false | DHW | 29 | 1 | 1 | | dhw.seltemp | selected temperature | uint8 (>=0<=254) | C | true | DHW | 30 | 1 | 1 | @@ -2983,10 +3005,11 @@ | dhw.tempok | temperature ok | boolean | | false | DHW | 60 | 1 | 1 | | dhw.active | active | boolean | | false | DHW | 61 | 1 | 1 | | dhw.3wayvalve | 3-way valve active | boolean | | false | DHW | 62 | 1 | 1 | -| dhw.mixertemp | mixer temperature | uint16 (>=0<=3199) | C | false | DHW | 63 | 1 | 1/10 | -| dhw.cylmiddletemp | cylinder middle temperature (TS3) | uint16 (>=0<=3199) | C | false | DHW | 64 | 1 | 1/10 | -| dhw.starts | starts | uint24 (>=0<=16777214) | | false | DHW | 65 | 2 | 1 | -| dhw.workm | active time | time (>=0<=16777214) | minutes | false | DHW | 67 | 2 | 1 | +| dhw.chargepump | charge pump | boolean | | false | DHW | 63 | 1 | 1 | +| dhw.mixertemp | mixer temperature | uint16 (>=0<=3199) | C | false | DHW | 64 | 1 | 1/10 | +| dhw.cylmiddletemp | cylinder middle temperature (TS3) | uint16 (>=0<=3199) | C | false | DHW | 65 | 1 | 1/10 | +| dhw.starts | starts | uint24 (>=0<=16777214) | | false | DHW | 66 | 2 | 1 | +| dhw.workm | active time | time (>=0<=16777214) | minutes | false | DHW | 68 | 2 | 1 | | nompower | nominal Power | uint8 (>=0<=254) | kW | true | DEVICE_DATA | 270 | 1 | 1 | | nrgtotal | total energy | uint24 (>=0<=167772) | kWh | false | DEVICE_DATA | 83 | 2 | 1/100 | | nrgheat | energy heating | uint24 (>=0<=10000000) | kWh | true | DEVICE_DATA | 85 | 2 | 1/100 | @@ -3063,9 +3086,9 @@ | meterheat | meter heating | uint24 (>=0<=1677721) | kWh | false | DEVICE_DATA | 95 | 2 | 1/10 | | dhw.meter | meter | uint24 (>=0<=1677721) | kWh | false | DHW | 2 | 2 | 1/10 | | gasmeterheat | gas meter heating | uint24 (>=0<=1677721) | kWh | false | DEVICE_DATA | 266 | 2 | 1/10 | -| dhw.gasmeter | gas meter | uint24 (>=0<=1677721) | kWh | false | DHW | 69 | 2 | 1/10 | +| dhw.gasmeter | gas meter | uint24 (>=0<=1677721) | kWh | false | DHW | 70 | 2 | 1/10 | | nrgheat2 | energy heating 2 | uint24 (>=0<=1677721) | kWh | false | DEVICE_DATA | 268 | 2 | 1/10 | -| dhw.nrg2 | energy 2 | uint24 (>=0<=1677721) | kWh | false | DHW | 71 | 2 | 1/10 | +| dhw.nrg2 | energy 2 | uint24 (>=0<=1677721) | kWh | false | DHW | 72 | 2 | 1/10 | | dhw.tapactivated | turn on/off | boolean | | true | DHW | 28 | 1 | 1 | | dhw.settemp | set temperature | uint8 (>=0<=254) | C | false | DHW | 29 | 1 | 1 | | dhw.seltemp | selected temperature | uint8 (>=0<=254) | C | true | DHW | 30 | 1 | 1 | @@ -3101,10 +3124,11 @@ | dhw.tempok | temperature ok | boolean | | false | DHW | 60 | 1 | 1 | | dhw.active | active | boolean | | false | DHW | 61 | 1 | 1 | | dhw.3wayvalve | 3-way valve active | boolean | | false | DHW | 62 | 1 | 1 | -| dhw.mixertemp | mixer temperature | uint16 (>=0<=3199) | C | false | DHW | 63 | 1 | 1/10 | -| dhw.cylmiddletemp | cylinder middle temperature (TS3) | uint16 (>=0<=3199) | C | false | DHW | 64 | 1 | 1/10 | -| dhw.starts | starts | uint24 (>=0<=16777214) | | false | DHW | 65 | 2 | 1 | -| dhw.workm | active time | time (>=0<=16777214) | minutes | false | DHW | 67 | 2 | 1 | +| dhw.chargepump | charge pump | boolean | | false | DHW | 63 | 1 | 1 | +| dhw.mixertemp | mixer temperature | uint16 (>=0<=3199) | C | false | DHW | 64 | 1 | 1/10 | +| dhw.cylmiddletemp | cylinder middle temperature (TS3) | uint16 (>=0<=3199) | C | false | DHW | 65 | 1 | 1/10 | +| dhw.starts | starts | uint24 (>=0<=16777214) | | false | DHW | 66 | 2 | 1 | +| dhw.workm | active time | time (>=0<=16777214) | minutes | false | DHW | 68 | 2 | 1 | | nompower | nominal Power | uint8 (>=0<=254) | kW | true | DEVICE_DATA | 270 | 1 | 1 | | nrgtotal | total energy | uint24 (>=0<=167772) | kWh | false | DEVICE_DATA | 83 | 2 | 1/100 | | nrgheat | energy heating | uint24 (>=0<=10000000) | kWh | true | DEVICE_DATA | 85 | 2 | 1/100 | @@ -3181,9 +3205,9 @@ | meterheat | meter heating | uint24 (>=0<=1677721) | kWh | false | DEVICE_DATA | 95 | 2 | 1/10 | | dhw.meter | meter | uint24 (>=0<=1677721) | kWh | false | DHW | 2 | 2 | 1/10 | | gasmeterheat | gas meter heating | uint24 (>=0<=1677721) | kWh | false | DEVICE_DATA | 266 | 2 | 1/10 | -| dhw.gasmeter | gas meter | uint24 (>=0<=1677721) | kWh | false | DHW | 69 | 2 | 1/10 | +| dhw.gasmeter | gas meter | uint24 (>=0<=1677721) | kWh | false | DHW | 70 | 2 | 1/10 | | nrgheat2 | energy heating 2 | uint24 (>=0<=1677721) | kWh | false | DEVICE_DATA | 268 | 2 | 1/10 | -| dhw.nrg2 | energy 2 | uint24 (>=0<=1677721) | kWh | false | DHW | 71 | 2 | 1/10 | +| dhw.nrg2 | energy 2 | uint24 (>=0<=1677721) | kWh | false | DHW | 72 | 2 | 1/10 | | dhw.tapactivated | turn on/off | boolean | | true | DHW | 28 | 1 | 1 | | dhw.settemp | set temperature | uint8 (>=0<=254) | C | false | DHW | 29 | 1 | 1 | | dhw.seltemp | selected temperature | uint8 (>=0<=254) | C | true | DHW | 30 | 1 | 1 | @@ -3219,10 +3243,11 @@ | dhw.tempok | temperature ok | boolean | | false | DHW | 60 | 1 | 1 | | dhw.active | active | boolean | | false | DHW | 61 | 1 | 1 | | dhw.3wayvalve | 3-way valve active | boolean | | false | DHW | 62 | 1 | 1 | -| dhw.mixertemp | mixer temperature | uint16 (>=0<=3199) | C | false | DHW | 63 | 1 | 1/10 | -| dhw.cylmiddletemp | cylinder middle temperature (TS3) | uint16 (>=0<=3199) | C | false | DHW | 64 | 1 | 1/10 | -| dhw.starts | starts | uint24 (>=0<=16777214) | | false | DHW | 65 | 2 | 1 | -| dhw.workm | active time | time (>=0<=16777214) | minutes | false | DHW | 67 | 2 | 1 | +| dhw.chargepump | charge pump | boolean | | false | DHW | 63 | 1 | 1 | +| dhw.mixertemp | mixer temperature | uint16 (>=0<=3199) | C | false | DHW | 64 | 1 | 1/10 | +| dhw.cylmiddletemp | cylinder middle temperature (TS3) | uint16 (>=0<=3199) | C | false | DHW | 65 | 1 | 1/10 | +| dhw.starts | starts | uint24 (>=0<=16777214) | | false | DHW | 66 | 2 | 1 | +| dhw.workm | active time | time (>=0<=16777214) | minutes | false | DHW | 68 | 2 | 1 | | nompower | nominal Power | uint8 (>=0<=254) | kW | true | DEVICE_DATA | 270 | 1 | 1 | | nrgtotal | total energy | uint24 (>=0<=167772) | kWh | false | DEVICE_DATA | 83 | 2 | 1/100 | | nrgheat | energy heating | uint24 (>=0<=10000000) | kWh | true | DEVICE_DATA | 85 | 2 | 1/100 | @@ -3299,9 +3324,9 @@ | meterheat | meter heating | uint24 (>=0<=1677721) | kWh | false | DEVICE_DATA | 95 | 2 | 1/10 | | dhw.meter | meter | uint24 (>=0<=1677721) | kWh | false | DHW | 2 | 2 | 1/10 | | gasmeterheat | gas meter heating | uint24 (>=0<=1677721) | kWh | false | DEVICE_DATA | 266 | 2 | 1/10 | -| dhw.gasmeter | gas meter | uint24 (>=0<=1677721) | kWh | false | DHW | 69 | 2 | 1/10 | +| dhw.gasmeter | gas meter | uint24 (>=0<=1677721) | kWh | false | DHW | 70 | 2 | 1/10 | | nrgheat2 | energy heating 2 | uint24 (>=0<=1677721) | kWh | false | DEVICE_DATA | 268 | 2 | 1/10 | -| dhw.nrg2 | energy 2 | uint24 (>=0<=1677721) | kWh | false | DHW | 71 | 2 | 1/10 | +| dhw.nrg2 | energy 2 | uint24 (>=0<=1677721) | kWh | false | DHW | 72 | 2 | 1/10 | | dhw.tapactivated | turn on/off | boolean | | true | DHW | 28 | 1 | 1 | | dhw.settemp | set temperature | uint8 (>=0<=254) | C | false | DHW | 29 | 1 | 1 | | dhw.seltemp | selected temperature | uint8 (>=0<=254) | C | true | DHW | 30 | 1 | 1 | @@ -3337,10 +3362,11 @@ | dhw.tempok | temperature ok | boolean | | false | DHW | 60 | 1 | 1 | | dhw.active | active | boolean | | false | DHW | 61 | 1 | 1 | | dhw.3wayvalve | 3-way valve active | boolean | | false | DHW | 62 | 1 | 1 | -| dhw.mixertemp | mixer temperature | uint16 (>=0<=3199) | C | false | DHW | 63 | 1 | 1/10 | -| dhw.cylmiddletemp | cylinder middle temperature (TS3) | uint16 (>=0<=3199) | C | false | DHW | 64 | 1 | 1/10 | -| dhw.starts | starts | uint24 (>=0<=16777214) | | false | DHW | 65 | 2 | 1 | -| dhw.workm | active time | time (>=0<=16777214) | minutes | false | DHW | 67 | 2 | 1 | +| dhw.chargepump | charge pump | boolean | | false | DHW | 63 | 1 | 1 | +| dhw.mixertemp | mixer temperature | uint16 (>=0<=3199) | C | false | DHW | 64 | 1 | 1/10 | +| dhw.cylmiddletemp | cylinder middle temperature (TS3) | uint16 (>=0<=3199) | C | false | DHW | 65 | 1 | 1/10 | +| dhw.starts | starts | uint24 (>=0<=16777214) | | false | DHW | 66 | 2 | 1 | +| dhw.workm | active time | time (>=0<=16777214) | minutes | false | DHW | 68 | 2 | 1 | | nompower | nominal Power | uint8 (>=0<=254) | kW | true | DEVICE_DATA | 270 | 1 | 1 | | nrgtotal | total energy | uint24 (>=0<=167772) | kWh | false | DEVICE_DATA | 83 | 2 | 1/100 | | nrgheat | energy heating | uint24 (>=0<=10000000) | kWh | true | DEVICE_DATA | 85 | 2 | 1/100 | @@ -3417,9 +3443,9 @@ | meterheat | meter heating | uint24 (>=0<=1677721) | kWh | false | DEVICE_DATA | 95 | 2 | 1/10 | | dhw.meter | meter | uint24 (>=0<=1677721) | kWh | false | DHW | 2 | 2 | 1/10 | | gasmeterheat | gas meter heating | uint24 (>=0<=1677721) | kWh | false | DEVICE_DATA | 266 | 2 | 1/10 | -| dhw.gasmeter | gas meter | uint24 (>=0<=1677721) | kWh | false | DHW | 69 | 2 | 1/10 | +| dhw.gasmeter | gas meter | uint24 (>=0<=1677721) | kWh | false | DHW | 70 | 2 | 1/10 | | nrgheat2 | energy heating 2 | uint24 (>=0<=1677721) | kWh | false | DEVICE_DATA | 268 | 2 | 1/10 | -| dhw.nrg2 | energy 2 | uint24 (>=0<=1677721) | kWh | false | DHW | 71 | 2 | 1/10 | +| dhw.nrg2 | energy 2 | uint24 (>=0<=1677721) | kWh | false | DHW | 72 | 2 | 1/10 | | dhw.tapactivated | turn on/off | boolean | | true | DHW | 28 | 1 | 1 | | dhw.settemp | set temperature | uint8 (>=0<=254) | C | false | DHW | 29 | 1 | 1 | | dhw.seltemp | selected temperature | uint8 (>=0<=254) | C | true | DHW | 30 | 1 | 1 | @@ -3455,10 +3481,11 @@ | dhw.tempok | temperature ok | boolean | | false | DHW | 60 | 1 | 1 | | dhw.active | active | boolean | | false | DHW | 61 | 1 | 1 | | dhw.3wayvalve | 3-way valve active | boolean | | false | DHW | 62 | 1 | 1 | -| dhw.mixertemp | mixer temperature | uint16 (>=0<=3199) | C | false | DHW | 63 | 1 | 1/10 | -| dhw.cylmiddletemp | cylinder middle temperature (TS3) | uint16 (>=0<=3199) | C | false | DHW | 64 | 1 | 1/10 | -| dhw.starts | starts | uint24 (>=0<=16777214) | | false | DHW | 65 | 2 | 1 | -| dhw.workm | active time | time (>=0<=16777214) | minutes | false | DHW | 67 | 2 | 1 | +| dhw.chargepump | charge pump | boolean | | false | DHW | 63 | 1 | 1 | +| dhw.mixertemp | mixer temperature | uint16 (>=0<=3199) | C | false | DHW | 64 | 1 | 1/10 | +| dhw.cylmiddletemp | cylinder middle temperature (TS3) | uint16 (>=0<=3199) | C | false | DHW | 65 | 1 | 1/10 | +| dhw.starts | starts | uint24 (>=0<=16777214) | | false | DHW | 66 | 2 | 1 | +| dhw.workm | active time | time (>=0<=16777214) | minutes | false | DHW | 68 | 2 | 1 | | nompower | nominal Power | uint8 (>=0<=254) | kW | true | DEVICE_DATA | 270 | 1 | 1 | | nrgtotal | total energy | uint24 (>=0<=167772) | kWh | false | DEVICE_DATA | 83 | 2 | 1/100 | | nrgheat | energy heating | uint24 (>=0<=10000000) | kWh | true | DEVICE_DATA | 85 | 2 | 1/100 | @@ -3535,9 +3562,9 @@ | meterheat | meter heating | uint24 (>=0<=1677721) | kWh | false | DEVICE_DATA | 95 | 2 | 1/10 | | dhw.meter | meter | uint24 (>=0<=1677721) | kWh | false | DHW | 2 | 2 | 1/10 | | gasmeterheat | gas meter heating | uint24 (>=0<=1677721) | kWh | false | DEVICE_DATA | 266 | 2 | 1/10 | -| dhw.gasmeter | gas meter | uint24 (>=0<=1677721) | kWh | false | DHW | 69 | 2 | 1/10 | +| dhw.gasmeter | gas meter | uint24 (>=0<=1677721) | kWh | false | DHW | 70 | 2 | 1/10 | | nrgheat2 | energy heating 2 | uint24 (>=0<=1677721) | kWh | false | DEVICE_DATA | 268 | 2 | 1/10 | -| dhw.nrg2 | energy 2 | uint24 (>=0<=1677721) | kWh | false | DHW | 71 | 2 | 1/10 | +| dhw.nrg2 | energy 2 | uint24 (>=0<=1677721) | kWh | false | DHW | 72 | 2 | 1/10 | | dhw.tapactivated | turn on/off | boolean | | true | DHW | 28 | 1 | 1 | | dhw.settemp | set temperature | uint8 (>=0<=254) | C | false | DHW | 29 | 1 | 1 | | dhw.seltemp | selected temperature | uint8 (>=0<=254) | C | true | DHW | 30 | 1 | 1 | @@ -3573,10 +3600,11 @@ | dhw.tempok | temperature ok | boolean | | false | DHW | 60 | 1 | 1 | | dhw.active | active | boolean | | false | DHW | 61 | 1 | 1 | | dhw.3wayvalve | 3-way valve active | boolean | | false | DHW | 62 | 1 | 1 | -| dhw.mixertemp | mixer temperature | uint16 (>=0<=3199) | C | false | DHW | 63 | 1 | 1/10 | -| dhw.cylmiddletemp | cylinder middle temperature (TS3) | uint16 (>=0<=3199) | C | false | DHW | 64 | 1 | 1/10 | -| dhw.starts | starts | uint24 (>=0<=16777214) | | false | DHW | 65 | 2 | 1 | -| dhw.workm | active time | time (>=0<=16777214) | minutes | false | DHW | 67 | 2 | 1 | +| dhw.chargepump | charge pump | boolean | | false | DHW | 63 | 1 | 1 | +| dhw.mixertemp | mixer temperature | uint16 (>=0<=3199) | C | false | DHW | 64 | 1 | 1/10 | +| dhw.cylmiddletemp | cylinder middle temperature (TS3) | uint16 (>=0<=3199) | C | false | DHW | 65 | 1 | 1/10 | +| dhw.starts | starts | uint24 (>=0<=16777214) | | false | DHW | 66 | 2 | 1 | +| dhw.workm | active time | time (>=0<=16777214) | minutes | false | DHW | 68 | 2 | 1 | | nompower | nominal Power | uint8 (>=0<=254) | kW | true | DEVICE_DATA | 270 | 1 | 1 | | nrgtotal | total energy | uint24 (>=0<=167772) | kWh | false | DEVICE_DATA | 83 | 2 | 1/100 | | nrgheat | energy heating | uint24 (>=0<=10000000) | kWh | true | DEVICE_DATA | 85 | 2 | 1/100 | @@ -3653,9 +3681,9 @@ | meterheat | meter heating | uint24 (>=0<=1677721) | kWh | false | DEVICE_DATA | 95 | 2 | 1/10 | | dhw.meter | meter | uint24 (>=0<=1677721) | kWh | false | DHW | 2 | 2 | 1/10 | | gasmeterheat | gas meter heating | uint24 (>=0<=1677721) | kWh | false | DEVICE_DATA | 266 | 2 | 1/10 | -| dhw.gasmeter | gas meter | uint24 (>=0<=1677721) | kWh | false | DHW | 69 | 2 | 1/10 | +| dhw.gasmeter | gas meter | uint24 (>=0<=1677721) | kWh | false | DHW | 70 | 2 | 1/10 | | nrgheat2 | energy heating 2 | uint24 (>=0<=1677721) | kWh | false | DEVICE_DATA | 268 | 2 | 1/10 | -| dhw.nrg2 | energy 2 | uint24 (>=0<=1677721) | kWh | false | DHW | 71 | 2 | 1/10 | +| dhw.nrg2 | energy 2 | uint24 (>=0<=1677721) | kWh | false | DHW | 72 | 2 | 1/10 | | dhw.tapactivated | turn on/off | boolean | | true | DHW | 28 | 1 | 1 | | dhw.settemp | set temperature | uint8 (>=0<=254) | C | false | DHW | 29 | 1 | 1 | | dhw.seltemp | selected temperature | uint8 (>=0<=254) | C | true | DHW | 30 | 1 | 1 | @@ -3691,10 +3719,11 @@ | dhw.tempok | temperature ok | boolean | | false | DHW | 60 | 1 | 1 | | dhw.active | active | boolean | | false | DHW | 61 | 1 | 1 | | dhw.3wayvalve | 3-way valve active | boolean | | false | DHW | 62 | 1 | 1 | -| dhw.mixertemp | mixer temperature | uint16 (>=0<=3199) | C | false | DHW | 63 | 1 | 1/10 | -| dhw.cylmiddletemp | cylinder middle temperature (TS3) | uint16 (>=0<=3199) | C | false | DHW | 64 | 1 | 1/10 | -| dhw.starts | starts | uint24 (>=0<=16777214) | | false | DHW | 65 | 2 | 1 | -| dhw.workm | active time | time (>=0<=16777214) | minutes | false | DHW | 67 | 2 | 1 | +| dhw.chargepump | charge pump | boolean | | false | DHW | 63 | 1 | 1 | +| dhw.mixertemp | mixer temperature | uint16 (>=0<=3199) | C | false | DHW | 64 | 1 | 1/10 | +| dhw.cylmiddletemp | cylinder middle temperature (TS3) | uint16 (>=0<=3199) | C | false | DHW | 65 | 1 | 1/10 | +| dhw.starts | starts | uint24 (>=0<=16777214) | | false | DHW | 66 | 2 | 1 | +| dhw.workm | active time | time (>=0<=16777214) | minutes | false | DHW | 68 | 2 | 1 | | nompower | nominal Power | uint8 (>=0<=254) | kW | true | DEVICE_DATA | 270 | 1 | 1 | | nrgtotal | total energy | uint24 (>=0<=167772) | kWh | false | DEVICE_DATA | 83 | 2 | 1/100 | | nrgheat | energy heating | uint24 (>=0<=10000000) | kWh | true | DEVICE_DATA | 85 | 2 | 1/100 | diff --git a/docs/dump_entities.csv b/docs/dump_entities.csv index 0a1ff02d6..e84f04c3a 100644 --- a/docs/dump_entities.csv +++ b/docs/dump_entities.csv @@ -1,211 +1,212 @@ device name,device type,product id,shortname,fullname,type [options...] \| (min/max),uom,writeable,discovery entityid v3.4,discovery entityid,modbus unit identifier,modbus block,modbus scale factor,modbus offset,modbus count -"CS*800i, Logatherm WLW*",boiler,8,reset,reset,cmd [-\|maintenance\|error\|history\|message], ,true,sensor.boiler_reset,sensor.boiler_reset,5,0,1,0,1 -"CS*800i, Logatherm WLW*",boiler,8,heatingoff,force heating off,boolean, ,true,switch.boiler_force_heating_off,switch.boiler_heatingoff,5,0,1,1,1 -"CS*800i, Logatherm WLW*",boiler,8,heatingactive,heating active,boolean, ,false,binary_sensor.boiler_heating_active,binary_sensor.boiler_heatingactive,5,0,1,2,1 -"CS*800i, Logatherm WLW*",boiler,8,tapwateractive,tapwater active,boolean, ,false,binary_sensor.boiler_tapwater_active,binary_sensor.boiler_tapwateractive,5,0,1,3,1 -"CS*800i, Logatherm WLW*",boiler,8,selflowtemp,selected flow temperature,uint8 (>=0<=90),C,true,number.boiler_selected_flow_temperature,number.boiler_selflowtemp,5,0,1,4,1 -"CS*800i, Logatherm WLW*",boiler,8,heatingpumpmod,heating pump modulation,uint8 (>=0<=100),%,false,sensor.boiler_heating_pump_modulation,sensor.boiler_heatingpumpmod,5,0,1,5,1 -"CS*800i, Logatherm WLW*",boiler,8,outdoortemp,outside temperature,int16 (>=-3199<=3199),C,false,sensor.boiler_outside_temperature,sensor.boiler_outdoortemp,5,0,1/10,6,1 -"CS*800i, Logatherm WLW*",boiler,8,curflowtemp,current flow temperature,uint16 (>=0<=3199),C,false,sensor.boiler_current_flow_temperature,sensor.boiler_curflowtemp,5,0,1/10,7,1 -"CS*800i, Logatherm WLW*",boiler,8,rettemp,return temperature,uint16 (>=0<=3199),C,false,sensor.boiler_return_temperature,sensor.boiler_rettemp,5,0,1/10,8,1 -"CS*800i, Logatherm WLW*",boiler,8,switchtemp,mixing switch temperature,uint16 (>=0<=3199),C,false,sensor.boiler_mixing_switch_temperature,sensor.boiler_switchtemp,5,0,1/10,9,1 -"CS*800i, Logatherm WLW*",boiler,8,syspress,system pressure,uint8 (>=0<=25),bar,false,sensor.boiler_system_pressure,sensor.boiler_syspress,5,0,1/10,10,1 -"CS*800i, Logatherm WLW*",boiler,8,boiltemp,actual boiler temperature,uint16 (>=0<=3199),C,false,sensor.boiler_actual_boiler_temperature,sensor.boiler_boiltemp,5,0,1/10,11,1 -"CS*800i, Logatherm WLW*",boiler,8,headertemp,low loss header,uint16 (>=0<=3199),C,false,sensor.boiler_low_loss_header,sensor.boiler_headertemp,5,0,1/10,12,1 -"CS*800i, Logatherm WLW*",boiler,8,heatingactivated,heating activated,boolean, ,true,switch.boiler_heating_activated,switch.boiler_heatingactivated,5,0,1,13,1 -"CS*800i, Logatherm WLW*",boiler,8,heatingtemp,heating temperature,uint8 (>=0<=90),C,true,number.boiler_heating_temperature,number.boiler_heatingtemp,5,0,1,14,1 -"CS*800i, Logatherm WLW*",boiler,8,heatingpump,heating pump,boolean, ,false,binary_sensor.boiler_heating_pump,binary_sensor.boiler_heatingpump,5,0,1,15,1 -"CS*800i, Logatherm WLW*",boiler,8,pumpmodmax,boiler pump max power,uint8 (>=0<=100),%,true,number.boiler_boiler_pump_max_power,number.boiler_pumpmodmax,5,0,1,16,1 -"CS*800i, Logatherm WLW*",boiler,8,pumpmodmin,boiler pump min power,uint8 (>=0<=100),%,true,number.boiler_boiler_pump_min_power,number.boiler_pumpmodmin,5,0,1,17,1 -"CS*800i, Logatherm WLW*",boiler,8,pumpmode,boiler pump mode,enum [proportional\|deltaP-1\|deltaP-2\|deltaP-3\|deltaP-4], ,true,select.boiler_boiler_pump_mode,select.boiler_pumpmode,5,0,1,18,1 -"CS*800i, Logatherm WLW*",boiler,8,pumpcharacter,boiler pump characteristic,enum [proportional\|150mbar\|200mbar\|250mbar\|300mbar\|350mbar\|400mbar], ,true,select.boiler_boiler_pump_characteristic,select.boiler_pumpcharacter,5,0,1,19,1 -"CS*800i, Logatherm WLW*",boiler,8,pumpdelay,pump delay,uint8 (>=0<=60),minutes,true,number.boiler_pump_delay,number.boiler_pumpdelay,5,0,1,20,1 -"CS*800i, Logatherm WLW*",boiler,8,pumpontemp,pump logic temperature,uint8 (>=0<=60),C,true,number.boiler_pump_logic_temperature,number.boiler_pumpontemp,5,0,1,21,1 -"CS*800i, Logatherm WLW*",boiler,8,selburnpow,burner selected max power,uint8 (>=0<=254),%,true,number.boiler_burner_selected_max_power,number.boiler_selburnpow,5,0,1,22,1 -"CS*800i, Logatherm WLW*",boiler,8,curburnpow,burner current power,uint8 (>=0<=100),%,false,sensor.boiler_burner_current_power,sensor.boiler_curburnpow,5,0,1,23,1 -"CS*800i, Logatherm WLW*",boiler,8,burnstarts,burner starts,uint24 (>=0<=16777214), ,false,sensor.boiler_burner_starts,sensor.boiler_burnstarts,5,0,1,24,2 -"CS*800i, Logatherm WLW*",boiler,8,burnworkmin,total burner operating time,time (>=0<=16777214),minutes,false,sensor.boiler_total_burner_operating_time,sensor.boiler_burnworkmin,5,0,1,26,2 -"CS*800i, Logatherm WLW*",boiler,8,burn2workmin,burner stage 2 operating time,time (>=0<=16777214),minutes,false,sensor.boiler_burner_stage_2_operating_time,sensor.boiler_burn2workmin,5,0,1,28,2 -"CS*800i, Logatherm WLW*",boiler,8,heatworkmin,total heat operating time,time (>=0<=16777214),minutes,false,sensor.boiler_total_heat_operating_time,sensor.boiler_heatworkmin,5,0,1,30,2 -"CS*800i, Logatherm WLW*",boiler,8,heatstarts,burner starts heating,uint24 (>=0<=16777214), ,false,sensor.boiler_burner_starts_heating,sensor.boiler_heatstarts,5,0,1,32,2 -"CS*800i, Logatherm WLW*",boiler,8,ubauptime,total UBA operating time,time (>=0<=16777214),minutes,false,sensor.boiler_total_UBA_operating_time,sensor.boiler_ubauptime,5,0,1,34,2 -"CS*800i, Logatherm WLW*",boiler,8,lastcode,last error code,string, ,false,sensor.boiler_last_error_code,sensor.boiler_lastcode,5,0,1,36,28 -"CS*800i, Logatherm WLW*",boiler,8,servicecode,service code,string, ,false,sensor.boiler_service_code,sensor.boiler_servicecode,5,0,1,64,2 -"CS*800i, Logatherm WLW*",boiler,8,servicecodenumber,service code number,uint16 (>=0<=31999), ,false,sensor.boiler_service_code_number,sensor.boiler_servicecodenumber,5,0,1,66,1 -"CS*800i, Logatherm WLW*",boiler,8,maintenancemessage,maintenance message,string, ,false,sensor.boiler_maintenance_message,sensor.boiler_maintenancemessage,5,0,1,67,2 -"CS*800i, Logatherm WLW*",boiler,8,maintenance,maintenance scheduled,enum [off\|time\|date\|manual], ,true,select.boiler_maintenance_scheduled,select.boiler_maintenance,5,0,1,69,1 -"CS*800i, Logatherm WLW*",boiler,8,maintenancetime,time to next maintenance,uint16 (>=0<=31999),hours,true,number.boiler_time_to_next_maintenance,number.boiler_maintenancetime,5,0,1,70,1 -"CS*800i, Logatherm WLW*",boiler,8,maintenancedate,next maintenance date,string, ,true,sensor.boiler_next_maintenance_date,sensor.boiler_maintenancedate,5,0,1,71,6 -"CS*800i, Logatherm WLW*",boiler,8,emergencyops,emergency operation,boolean, ,true,switch.boiler_emergency_operation,switch.boiler_emergencyops,5,0,1,77,1 -"CS*800i, Logatherm WLW*",boiler,8,emergencytemp,emergency temperature,uint8 (>=15<=70),C,true,number.boiler_emergency_temperature,number.boiler_emergencytemp,5,0,1,78,1 -"CS*800i, Logatherm WLW*",boiler,8,pc0flow,Flow PC0,int16 (>=-31999<=31999),l/h,false,sensor.boiler_Flow_PC0,sensor.boiler_pc0flow,5,0,1,79,1 -"CS*800i, Logatherm WLW*",boiler,8,pc1flow,Flow PC1,int16 (>=-31999<=31999),l/h,false,sensor.boiler_Flow_PC1,sensor.boiler_pc1flow,5,0,1,80,1 -"CS*800i, Logatherm WLW*",boiler,8,pc1on,PC1,boolean, ,false,binary_sensor.boiler_PC1,binary_sensor.boiler_pc1on,5,0,1,81,1 -"CS*800i, Logatherm WLW*",boiler,8,pc1rate,PC1 rate,uint8 (>=0<=100),%,false,sensor.boiler_PC1_rate,sensor.boiler_pc1rate,5,0,1,82,1 -"CS*800i, Logatherm WLW*",boiler,8,nrgtotal,total energy,uint24 (>=0<=167772),kWh,false,sensor.boiler_total_energy,sensor.boiler_nrgtotal,5,0,1/100,83,2 -"CS*800i, Logatherm WLW*",boiler,8,dhw.nrg,energy,uint24 (>=0<=167772),kWh,false,sensor.boiler_dhw_energy,sensor.boiler_dhw_nrg,5,9,1/100,0,2 -"CS*800i, Logatherm WLW*",boiler,8,nrgheat,energy heating,uint24 (>=0<=167772),kWh,false,sensor.boiler_energy_heating,sensor.boiler_nrgheat,5,0,1/100,85,2 -"CS*800i, Logatherm WLW*",boiler,8,nrgcool,energy cooling,uint24 (>=0<=167772),kWh,false,sensor.boiler_energy_cooling,sensor.boiler_nrgcool,5,0,1/100,87,2 -"CS*800i, Logatherm WLW*",boiler,8,metertotal,meter total,uint24 (>=0<=167772),kWh,false,sensor.boiler_meter_total,sensor.boiler_metertotal,5,0,1/100,89,2 -"CS*800i, Logatherm WLW*",boiler,8,metercomp,meter compressor,uint24 (>=0<=167772),kWh,false,sensor.boiler_meter_compressor,sensor.boiler_metercomp,5,0,1/100,91,2 -"CS*800i, Logatherm WLW*",boiler,8,metereheat,meter e-heater,uint24 (>=0<=167772),kWh,false,sensor.boiler_meter_e-heater,sensor.boiler_metereheat,5,0,1/100,93,2 -"CS*800i, Logatherm WLW*",boiler,8,meterheat,meter heating,uint24 (>=0<=167772),kWh,false,sensor.boiler_meter_heating,sensor.boiler_meterheat,5,0,1/100,95,2 -"CS*800i, Logatherm WLW*",boiler,8,metercool,meter cooling,uint24 (>=0<=167772),kWh,false,sensor.boiler_meter_cooling,sensor.boiler_metercool,5,0,1/100,97,2 -"CS*800i, Logatherm WLW*",boiler,8,dhw.meter,meter,uint24 (>=0<=167772),kWh,false,sensor.boiler_dhw_meter,sensor.boiler_dhw_meter,5,9,1/100,2,2 -"CS*800i, Logatherm WLW*",boiler,8,uptimetotal,heatpump total uptime,time (>=0<=279620),minutes,false,sensor.boiler_heatpump_total_uptime,sensor.boiler_uptimetotal,5,0,1/60,99,2 -"CS*800i, Logatherm WLW*",boiler,8,uptimecontrol,total operating time heat,time (>=0<=279620),minutes,false,sensor.boiler_total_operating_time_heat,sensor.boiler_uptimecontrol,5,0,1/60,101,2 -"CS*800i, Logatherm WLW*",boiler,8,uptimecompheating,operating time compressor heating,time (>=0<=279620),minutes,false,sensor.boiler_operating_time_compressor_heating,sensor.boiler_uptimecompheating,5,0,1/60,103,2 -"CS*800i, Logatherm WLW*",boiler,8,uptimecompcooling,operating time compressor cooling,time (>=0<=279620),minutes,false,sensor.boiler_operating_time_compressor_cooling,sensor.boiler_uptimecompcooling,5,0,1/60,105,2 -"CS*800i, Logatherm WLW*",boiler,8,dhw.uptimecomp,operating time compressor,time (>=0<=279620),minutes,false,sensor.boiler_dhw_operating_time_compressor,sensor.boiler_dhw_uptimecomp,5,9,1/60,4,2 -"CS*800i, Logatherm WLW*",boiler,8,uptimecomppool,operating time compressor pool,time (>=0<=279620),minutes,false,sensor.boiler_operating_time_compressor_pool,sensor.boiler_uptimecomppool,5,0,1/60,107,2 -"CS*800i, Logatherm WLW*",boiler,8,totalcompstarts,total compressor control starts,uint24 (>=0<=16777214), ,false,sensor.boiler_total_compressor_control_starts,sensor.boiler_totalcompstarts,5,0,1,109,2 -"CS*800i, Logatherm WLW*",boiler,8,heatingstarts,heating control starts,uint24 (>=0<=16777214), ,false,sensor.boiler_heating_control_starts,sensor.boiler_heatingstarts,5,0,1,111,2 -"CS*800i, Logatherm WLW*",boiler,8,coolingstarts,cooling control starts,uint24 (>=0<=16777214), ,false,sensor.boiler_cooling_control_starts,sensor.boiler_coolingstarts,5,0,1,113,2 -"CS*800i, Logatherm WLW*",boiler,8,dhw.startshp,starts hp,uint24 (>=0<=16777214), ,false,sensor.boiler_dhw_starts_hp,sensor.boiler_dhw_startshp,5,9,1,6,2 -"CS*800i, Logatherm WLW*",boiler,8,poolstarts,pool control starts,uint24 (>=0<=16777214), ,false,sensor.boiler_pool_control_starts,sensor.boiler_poolstarts,5,0,1,115,2 -"CS*800i, Logatherm WLW*",boiler,8,nrgconstotal,total energy consumption,uint24 (>=0<=16777214),kWh,false,sensor.boiler_total_energy_consumption,sensor.boiler_nrgconstotal,5,0,1,117,2 -"CS*800i, Logatherm WLW*",boiler,8,nrgconscomptotal,total energy consumption compressor,uint24 (>=0<=16777214),kWh,false,sensor.boiler_total_energy_consumption_compressor,sensor.boiler_nrgconscomptotal,5,0,1,119,2 -"CS*800i, Logatherm WLW*",boiler,8,nrgconscompheating,energy consumption compressor heating,uint24 (>=0<=16777214),kWh,false,sensor.boiler_energy_consumption_compressor_heating,sensor.boiler_nrgconscompheating,5,0,1,121,2 -"CS*800i, Logatherm WLW*",boiler,8,dhw.nrgconscomp,energy consumption compressor,uint24 (>=0<=16777214),kWh,false,sensor.boiler_dhw_energy_consumption_compressor,sensor.boiler_dhw_nrgconscomp,5,9,1,8,2 -"CS*800i, Logatherm WLW*",boiler,8,nrgconscompcooling,energy consumption compressor cooling,uint24 (>=0<=16777214),kWh,false,sensor.boiler_energy_consumption_compressor_cooling,sensor.boiler_nrgconscompcooling,5,0,1,123,2 -"CS*800i, Logatherm WLW*",boiler,8,nrgconscomppool,energy consumption compressor pool,uint24 (>=0<=16777214),kWh,false,sensor.boiler_energy_consumption_compressor_pool,sensor.boiler_nrgconscomppool,5,0,1,125,2 -"CS*800i, Logatherm WLW*",boiler,8,auxelecheatnrgconstotal,total aux elec. heater energy consumption,uint24 (>=0<=16777214),kWh,false,sensor.boiler_total_aux_elec._heater_energy_consumption,sensor.boiler_auxelecheatnrgconstotal,5,0,1,127,2 -"CS*800i, Logatherm WLW*",boiler,8,auxelecheatnrgconsheating,aux elec. heater energy consumption heating,uint24 (>=0<=16777214),kWh,false,sensor.boiler_aux_elec._heater_energy_consumption_heating,sensor.boiler_auxelecheatnrgconsheating,5,0,1,129,2 -"CS*800i, Logatherm WLW*",boiler,8,dhw.auxelecheatnrgcons,aux elec. heater energy consumption,uint24 (>=0<=16777214),kWh,false,sensor.boiler_dhw_aux_elec._heater_energy_consumption,sensor.boiler_dhw_auxelecheatnrgcons,5,9,1,10,2 -"CS*800i, Logatherm WLW*",boiler,8,auxelecheatnrgconspool,aux elec. heater energy consumption pool,uint24 (>=0<=16777214),kWh,false,sensor.boiler_aux_elec._heater_energy_consumption_pool,sensor.boiler_auxelecheatnrgconspool,5,0,1,131,2 -"CS*800i, Logatherm WLW*",boiler,8,nrgsupptotal,total energy supplied,uint24 (>=0<=16777214),kWh,false,sensor.boiler_total_energy_supplied,sensor.boiler_nrgsupptotal,5,0,1,133,2 -"CS*800i, Logatherm WLW*",boiler,8,nrgsuppheating,total energy supplied heating,uint24 (>=0<=16777214),kWh,false,sensor.boiler_total_energy_supplied_heating,sensor.boiler_nrgsuppheating,5,0,1,135,2 -"CS*800i, Logatherm WLW*",boiler,8,dhw.nrgsupp,total energy warm supplied,uint24 (>=0<=16777214),kWh,false,sensor.boiler_dhw_total_energy_warm_supplied,sensor.boiler_dhw_nrgsupp,5,9,1,12,2 -"CS*800i, Logatherm WLW*",boiler,8,nrgsuppcooling,total energy supplied cooling,uint24 (>=0<=16777214),kWh,false,sensor.boiler_total_energy_supplied_cooling,sensor.boiler_nrgsuppcooling,5,0,1,137,2 -"CS*800i, Logatherm WLW*",boiler,8,nrgsupppool,total energy supplied pool,uint24 (>=0<=16777214),kWh,false,sensor.boiler_total_energy_supplied_pool,sensor.boiler_nrgsupppool,5,0,1,139,2 -"CS*800i, Logatherm WLW*",boiler,8,hppower,compressor power output,uint16 (>=0<=3199),kW,false,sensor.boiler_compressor_power_output,sensor.boiler_hppower,5,0,1/10,141,1 -"CS*800i, Logatherm WLW*",boiler,8,hpmaxpower,compressor max power,uint8 (>=0<=100),%,true,number.boiler_compressor_max_power,number.boiler_hpmaxpower,5,0,1,142,1 -"CS*800i, Logatherm WLW*",boiler,8,pvmaxcomp,pv compressor max power,uint8 (>=0<=25),kW,true,number.boiler_pv_compressor_max_power,number.boiler_pvmaxcomp,5,0,1/10,143,1 -"CS*800i, Logatherm WLW*",boiler,8,powerreduction,power reduction,uint8 (>=30<=60),%,true,number.boiler_power_reduction,number.boiler_powerreduction,5,0,10,144,1 -"CS*800i, Logatherm WLW*",boiler,8,hpsetdiffpress,set differential pressure,uint8 (>=150<=750),mbar,true,number.boiler_set_differential_pressure,number.boiler_hpsetdiffpress,5,0,50,145,1 -"CS*800i, Logatherm WLW*",boiler,8,hpcompon,hp compressor,boolean, ,false,binary_sensor.boiler_hp_compressor,binary_sensor.boiler_hpcompon,5,0,1,146,1 -"CS*800i, Logatherm WLW*",boiler,8,hpactivity,compressor activity,enum [off\|heating\|cooling\|hot water\|pool\|pool heating\|defrost\|compressor alarm], ,false,sensor.boiler_compressor_activity,sensor.boiler_hpactivity,5,0,1,147,1 -"CS*800i, Logatherm WLW*",boiler,8,hpbrinepumpspd,brine pump speed,uint8 (>=0<=100),%,false,sensor.boiler_brine_pump_speed,sensor.boiler_hpbrinepumpspd,5,0,1,148,1 -"CS*800i, Logatherm WLW*",boiler,8,hpswitchvalve,switch valve,boolean, ,false,binary_sensor.boiler_switch_valve,binary_sensor.boiler_hpswitchvalve,5,0,1,149,1 -"CS*800i, Logatherm WLW*",boiler,8,hpcompspd,compressor speed,uint8 (>=0<=100),%,false,sensor.boiler_compressor_speed,sensor.boiler_hpcompspd,5,0,1,150,1 -"CS*800i, Logatherm WLW*",boiler,8,hpcircspd,circulation pump speed,uint8 (>=0<=100),%,false,sensor.boiler_circulation_pump_speed,sensor.boiler_hpcircspd,5,0,1,151,1 -"CS*800i, Logatherm WLW*",boiler,8,hpbrinein,brine in/evaporator,int16 (>=-3199<=3199),C,false,sensor.boiler_brine_in/evaporator,sensor.boiler_hpbrinein,5,0,1/10,152,1 -"CS*800i, Logatherm WLW*",boiler,8,hpbrineout,brine out/condenser,int16 (>=-3199<=3199),C,false,sensor.boiler_brine_out/condenser,sensor.boiler_hpbrineout,5,0,1/10,153,1 -"CS*800i, Logatherm WLW*",boiler,8,hptc0,heat carrier return (TC0),int16 (>=-3199<=3199),C,false,sensor.boiler_heat_carrier_return_(TC0),sensor.boiler_hptc0,5,0,1/10,154,1 -"CS*800i, Logatherm WLW*",boiler,8,hptc1,heat carrier forward (TC1),int16 (>=-3199<=3199),C,false,sensor.boiler_heat_carrier_forward_(TC1),sensor.boiler_hptc1,5,0,1/10,155,1 -"CS*800i, Logatherm WLW*",boiler,8,hptc3,condenser temperature (TC3),int16 (>=-3199<=3199),C,false,sensor.boiler_condenser_temperature_(TC3),sensor.boiler_hptc3,5,0,1/10,156,1 -"CS*800i, Logatherm WLW*",boiler,8,hptr1,compressor temperature (TR1),int16 (>=-3199<=3199),C,false,sensor.boiler_compressor_temperature_(TR1),sensor.boiler_hptr1,5,0,1/10,157,1 -"CS*800i, Logatherm WLW*",boiler,8,hptr3,refrigerant temperature liquid side (condenser output) (TR3),int16 (>=-3199<=3199),C,false,sensor.boiler_refrigerant_temperature_liquid_side_(condenser_output)_(TR3),sensor.boiler_hptr3,5,0,1/10,158,1 -"CS*800i, Logatherm WLW*",boiler,8,hptr4,evaporator inlet temperature (TR4),int16 (>=-3199<=3199),C,false,sensor.boiler_evaporator_inlet_temperature_(TR4),sensor.boiler_hptr4,5,0,1/10,159,1 -"CS*800i, Logatherm WLW*",boiler,8,hptr5,compressor inlet temperature (TR5),int16 (>=-3199<=3199),C,false,sensor.boiler_compressor_inlet_temperature_(TR5),sensor.boiler_hptr5,5,0,1/10,160,1 -"CS*800i, Logatherm WLW*",boiler,8,hptr6,compressor outlet temperature (TR6),int16 (>=-3199<=3199),C,false,sensor.boiler_compressor_outlet_temperature_(TR6),sensor.boiler_hptr6,5,0,1/10,161,1 -"CS*800i, Logatherm WLW*",boiler,8,hptr7,refrigerant temperature gas side (condenser input) (TR7),int16 (>=-3199<=3199),C,false,sensor.boiler_refrigerant_temperature_gas_side_(condenser_input)_(TR7),sensor.boiler_hptr7,5,0,1/10,162,1 -"CS*800i, Logatherm WLW*",boiler,8,hptl2,air inlet temperature (TL2),int16 (>=-3199<=3199),C,false,sensor.boiler_air_inlet_temperature_(TL2),sensor.boiler_hptl2,5,0,1/10,163,1 -"CS*800i, Logatherm WLW*",boiler,8,hppl1,low pressure side temperature (PL1),int16 (>=-3199<=3199),C,false,sensor.boiler_low_pressure_side_temperature_(PL1),sensor.boiler_hppl1,5,0,1/10,164,1 -"CS*800i, Logatherm WLW*",boiler,8,hpph1,high pressure side temperature (PH1),int16 (>=-3199<=3199),C,false,sensor.boiler_high_pressure_side_temperature_(PH1),sensor.boiler_hpph1,5,0,1/10,165,1 -"CS*800i, Logatherm WLW*",boiler,8,hpta4,drain pan temp (TA4),int16 (>=-3199<=3199),C,false,sensor.boiler_drain_pan_temp_(TA4),sensor.boiler_hpta4,5,0,1/10,166,1 -"CS*800i, Logatherm WLW*",boiler,8,hptw1,reservoir temp (TW1),int16 (>=-3199<=3199),C,false,sensor.boiler_reservoir_temp_(TW1),sensor.boiler_hptw1,5,0,1/10,167,1 -"CS*800i, Logatherm WLW*",boiler,8,poolsettemp,pool set temperature,uint8 (>=0<=127),C,true,number.boiler_pool_set_temperature,number.boiler_poolsettemp,5,0,1/2,168,1 -"CS*800i, Logatherm WLW*",boiler,8,hp4way,4-way valve (VR4),enum [cooling & defrost\|heating & dhw], ,false,sensor.boiler_4-way_valve_(VR4),sensor.boiler_hp4way,5,0,1,169,1 -"CS*800i, Logatherm WLW*",boiler,8,hpin1,input 1 state,boolean, ,false,binary_sensor.boiler_input_1_state,binary_sensor.boiler_hpin1,5,0,1,170,1 -"CS*800i, Logatherm WLW*",boiler,8,hpin1opt,input 1 options,string, ,true,sensor.boiler_input_1_options,sensor.boiler_hpin1opt,5,0,1,171,8 -"CS*800i, Logatherm WLW*",boiler,8,hpin2,input 2 state,boolean, ,false,binary_sensor.boiler_input_2_state,binary_sensor.boiler_hpin2,5,0,1,179,1 -"CS*800i, Logatherm WLW*",boiler,8,hpin2opt,input 2 options,string, ,true,sensor.boiler_input_2_options,sensor.boiler_hpin2opt,5,0,1,180,8 -"CS*800i, Logatherm WLW*",boiler,8,hpin3,input 3 state,boolean, ,false,binary_sensor.boiler_input_3_state,binary_sensor.boiler_hpin3,5,0,1,188,1 -"CS*800i, Logatherm WLW*",boiler,8,hpin3opt,input 3 options,string, ,true,sensor.boiler_input_3_options,sensor.boiler_hpin3opt,5,0,1,189,8 -"CS*800i, Logatherm WLW*",boiler,8,hpin4,input 4 state,boolean, ,false,binary_sensor.boiler_input_4_state,binary_sensor.boiler_hpin4,5,0,1,197,1 -"CS*800i, Logatherm WLW*",boiler,8,hpin4opt,input 4 options,string, ,true,sensor.boiler_input_4_options,sensor.boiler_hpin4opt,5,0,1,198,8 -"CS*800i, Logatherm WLW*",boiler,8,maxheatcomp,heat limit compressor,enum [0 kW\|2 kW\|3 kW\|4 kW\|6 kW\|9 kW], ,true,select.boiler_heat_limit_compressor,select.boiler_maxheatcomp,5,0,1,206,1 -"CS*800i, Logatherm WLW*",boiler,8,maxheatheat,heat limit heating,enum [0 kW\|2 kW\|3 kW\|4 kW\|6 kW\|9 kW], ,true,select.boiler_heat_limit_heating,select.boiler_maxheatheat,5,0,1,207,1 -"CS*800i, Logatherm WLW*",boiler,8,dhw.maxheat,heat limit,enum [0 kW\|2 kW\|3 kW\|4 kW\|6 kW\|9 kW], ,true,select.boiler_dhw_heat_limit,select.boiler_dhw_maxheat,5,9,1,14,1 -"CS*800i, Logatherm WLW*",boiler,8,auxheatersource,aux heater source,enum [not installed\|electric heater\|exclusive\|parallel\|hybrid], ,true,select.boiler_aux_heater_source,select.boiler_auxheatersource,5,0,1,208,1 -"CS*800i, Logatherm WLW*",boiler,8,pvcooling,cooling only with PV,boolean, ,true,switch.boiler_cooling_only_with_PV,switch.boiler_pvcooling,5,0,1,209,1 -"CS*800i, Logatherm WLW*",boiler,8,auxheateronly,aux heater only,boolean, ,true,switch.boiler_aux_heater_only,switch.boiler_auxheateronly,5,0,1,210,1 -"CS*800i, Logatherm WLW*",boiler,8,auxheateroff,disable aux heater,boolean, ,true,switch.boiler_disable_aux_heater,switch.boiler_auxheateroff,5,0,1,211,1 -"CS*800i, Logatherm WLW*",boiler,8,auxheaterstatus,aux heater status,enum [off\|heating\|cooling\|hot water\|pool\|pool heating\|defrost\|compressor alarm], ,false,sensor.boiler_aux_heater_status,sensor.boiler_auxheaterstatus,5,0,1,212,1 -"CS*800i, Logatherm WLW*",boiler,8,auxheaterlevel,aux heater level,uint8 (>=0<=100),%,false,sensor.boiler_aux_heater_level,sensor.boiler_auxheaterlevel,5,0,1,213,1 -"CS*800i, Logatherm WLW*",boiler,8,auxheaterdelay,aux heater on delay,uint16 (>=10<=1000),K*min,true,number.boiler_aux_heater_on_delay,number.boiler_auxheaterdelay,5,0,10,214,1 -"CS*800i, Logatherm WLW*",boiler,8,auxmaxlimit,aux heater max limit,uint8 (>=0<=10),K,true,number.boiler_aux_heater_max_limit,number.boiler_auxmaxlimit,5,0,1/10,215,1 -"CS*800i, Logatherm WLW*",boiler,8,auxlimitstart,aux heater limit start,uint8 (>=0<=10),K,true,number.boiler_aux_heater_limit_start,number.boiler_auxlimitstart,5,0,1/10,216,1 -"CS*800i, Logatherm WLW*",boiler,8,auxheatrmode,aux heater mode,enum [eco\|comfort], ,true,select.boiler_aux_heater_mode,select.boiler_auxheatrmode,5,0,1,217,1 -"CS*800i, Logatherm WLW*",boiler,8,hphystheat,on/off hyst heat,uint16 (>=50<=1500),K*min,true,number.boiler_on/off_hyst_heat,number.boiler_hphystheat,5,0,5,218,1 -"CS*800i, Logatherm WLW*",boiler,8,hphystcool,on/off hyst cool,uint16 (>=50<=1500),K*min,true,number.boiler_on/off_hyst_cool,number.boiler_hphystcool,5,0,5,219,1 -"CS*800i, Logatherm WLW*",boiler,8,hphystpool,on/off hyst pool,uint16 (>=50<=1500),K*min,true,number.boiler_on/off_hyst_pool,number.boiler_hphystpool,5,0,5,220,1 -"CS*800i, Logatherm WLW*",boiler,8,silentmode,silent mode,enum [off\|auto\|on], ,true,select.boiler_silent_mode,select.boiler_silentmode,5,0,1,221,1 -"CS*800i, Logatherm WLW*",boiler,8,silentfrom,silent mode from,uint8 (>=0<=3810),minutes,true,number.boiler_silent_mode_from,number.boiler_silentfrom,5,0,15,222,1 -"CS*800i, Logatherm WLW*",boiler,8,silentto,silent mode to,uint8 (>=0<=3810),minutes,true,number.boiler_silent_mode_to,number.boiler_silentto,5,0,15,223,1 -"CS*800i, Logatherm WLW*",boiler,8,mintempsilent,min outside temp for silent mode,int8 (>=-126<=126),C,true,number.boiler_min_outside_temp_for_silent_mode,number.boiler_mintempsilent,5,0,1,224,1 -"CS*800i, Logatherm WLW*",boiler,8,tempparmode,outside temp parallel mode,int8 (>=-126<=126),C,true,number.boiler_outside_temp_parallel_mode,number.boiler_tempparmode,5,0,1,225,1 -"CS*800i, Logatherm WLW*",boiler,8,auxheatmix,aux heater mixing valve,int8 (>=-100<=100),%,false,sensor.boiler_aux_heater_mixing_valve,sensor.boiler_auxheatmix,5,0,1,226,1 -"CS*800i, Logatherm WLW*",boiler,8,tempdiffheat,temp diff TC3/TC0 heat,uint8 (>=2<=10),K,true,number.boiler_temp_diff_TC3/TC0_heat,number.boiler_tempdiffheat,5,0,1/10,227,1 -"CS*800i, Logatherm WLW*",boiler,8,tempdiffcool,temp diff TC3/TC0 cool,uint8 (>=2<=10),K,true,number.boiler_temp_diff_TC3/TC0_cool,number.boiler_tempdiffcool,5,0,1/10,228,1 -"CS*800i, Logatherm WLW*",boiler,8,vpcooling,valve/pump cooling,boolean, ,true,switch.boiler_valve/pump_cooling,switch.boiler_vpcooling,5,0,1,229,1 -"CS*800i, Logatherm WLW*",boiler,8,heatcable,heating cable,boolean, ,true,switch.boiler_heating_cable,switch.boiler_heatcable,5,0,1,230,1 -"CS*800i, Logatherm WLW*",boiler,8,vc0valve,VC0 valve,boolean, ,true,switch.boiler_VC0_valve,switch.boiler_vc0valve,5,0,1,231,1 -"CS*800i, Logatherm WLW*",boiler,8,primepump,primary heatpump,boolean, ,true,switch.boiler_primary_heatpump,switch.boiler_primepump,5,0,1,232,1 -"CS*800i, Logatherm WLW*",boiler,8,primepumpmod,primary heatpump modulation,uint8 (>=0<=100),%,true,number.boiler_primary_heatpump_modulation,number.boiler_primepumpmod,5,0,1,233,1 -"CS*800i, Logatherm WLW*",boiler,8,hp3way,3-way valve,boolean, ,true,switch.boiler_3-way_valve,switch.boiler_hp3way,5,0,1,234,1 -"CS*800i, Logatherm WLW*",boiler,8,elheatstep1,el. heater step 1,boolean, ,true,switch.boiler_el._heater_step_1,switch.boiler_elheatstep1,5,0,1,235,1 -"CS*800i, Logatherm WLW*",boiler,8,elheatstep2,el. heater step 2,boolean, ,true,switch.boiler_el._heater_step_2,switch.boiler_elheatstep2,5,0,1,236,1 -"CS*800i, Logatherm WLW*",boiler,8,elheatstep3,el. heater step 3,boolean, ,true,switch.boiler_el._heater_step_3,switch.boiler_elheatstep3,5,0,1,237,1 -"CS*800i, Logatherm WLW*",boiler,8,hpea0,condensate reservoir heating (EA0),boolean, ,false,binary_sensor.boiler_condensate_reservoir_heating_(EA0),binary_sensor.boiler_hpea0,5,0,1,238,1 -"CS*800i, Logatherm WLW*",boiler,8,hppumpmode,primary heatpump mode,enum [auto\|continuous], ,true,select.boiler_primary_heatpump_mode,select.boiler_hppumpmode,5,0,1,239,1 -"CS*800i, Logatherm WLW*",boiler,8,fan,fan,uint8 (>=20<=100),%,true,number.boiler_fan,number.boiler_fan,5,0,1,240,1 -"CS*800i, Logatherm WLW*",boiler,8,shutdown,shutdown,cmd [off\|on], ,true,sensor.boiler_shutdown,sensor.boiler_shutdown,5,0,1,241,1 -"CS*800i, Logatherm WLW*",boiler,8,hpcurrpower,compressor current power,uint16 (>=0<=31999),W,false,sensor.boiler_compressor_current_power,sensor.boiler_hpcurrpower,5,0,1,242,1 -"CS*800i, Logatherm WLW*",boiler,8,hppowerlimit,power limit,uint16 (>=0<=31999),W,true,number.boiler_power_limit,number.boiler_hppowerlimit,5,0,1,243,1 -"CS*800i, Logatherm WLW*",boiler,8,dhw.alternatingop,alternating operation,boolean, ,true,switch.boiler_dhw_alternating_operation,switch.boiler_dhw_alternatingop,5,9,1,15,1 -"CS*800i, Logatherm WLW*",boiler,8,dhw.altopprioheat,prioritise heating during dhw,uint8 (>=20<=120),minutes,true,number.boiler_dhw_prioritise_heating_during_dhw,number.boiler_dhw_altopprioheat,5,9,1,16,1 -"CS*800i, Logatherm WLW*",boiler,8,dhw.altopprio,prioritise dhw during heating,uint8 (>=30<=120),minutes,true,number.boiler_dhw_prioritise_dhw_during_heating,number.boiler_dhw_altopprio,5,9,1,17,1 -"CS*800i, Logatherm WLW*",boiler,8,dhw.comfoff,comfort switch off,uint8 (>=15<=65),C,true,number.boiler_dhw_comfort_switch_off,number.boiler_dhw_comfoff,5,9,1,18,1 -"CS*800i, Logatherm WLW*",boiler,8,dhw.ecooff,eco switch off,uint8 (>=15<=65),C,true,number.boiler_dhw_eco_switch_off,number.boiler_dhw_ecooff,5,9,1,19,1 -"CS*800i, Logatherm WLW*",boiler,8,dhw.ecoplusoff,eco+ switch off,uint8 (>=48<=63),C,true,number.boiler_dhw_eco+_switch_off,number.boiler_dhw_ecoplusoff,5,9,1,20,1 -"CS*800i, Logatherm WLW*",boiler,8,dhw.comfdiff,comfort diff,uint8 (>=6<=12),K,true,number.boiler_dhw_comfort_diff,number.boiler_dhw_comfdiff,5,9,1,21,1 -"CS*800i, Logatherm WLW*",boiler,8,dhw.ecodiff,eco diff,uint8 (>=6<=12),K,true,number.boiler_dhw_eco_diff,number.boiler_dhw_ecodiff,5,9,1,22,1 -"CS*800i, Logatherm WLW*",boiler,8,dhw.ecoplusdiff,eco+ diff,uint8 (>=6<=12),K,true,number.boiler_dhw_eco+_diff,number.boiler_dhw_ecoplusdiff,5,9,1,23,1 -"CS*800i, Logatherm WLW*",boiler,8,dhw.comfstop,comfort stop temp,uint8 (>=0<=254),C,true,number.boiler_dhw_comfort_stop_temp,number.boiler_dhw_comfstop,5,9,1,24,1 -"CS*800i, Logatherm WLW*",boiler,8,dhw.ecostop,eco stop temp,uint8 (>=0<=254),C,true,number.boiler_dhw_eco_stop_temp,number.boiler_dhw_ecostop,5,9,1,25,1 -"CS*800i, Logatherm WLW*",boiler,8,dhw.ecoplusstop,eco+ stop temp,uint8 (>=0<=254),C,true,number.boiler_dhw_eco+_stop_temp,number.boiler_dhw_ecoplusstop,5,9,1,26,1 -"CS*800i, Logatherm WLW*",boiler,8,dhw.hpcircpump,circulation pump available during dhw,boolean, ,true,switch.boiler_dhw_circulation_pump_available_during_dhw,switch.boiler_dhw_hpcircpump,5,9,1,27,1 -"CS*800i, Logatherm WLW*",boiler,8,dhw.tapactivated,turn on/off,boolean, ,true,switch.boiler_dhw_turn_on/off,switch.boiler_dhw_tapactivated,5,9,1,28,1 -"CS*800i, Logatherm WLW*",boiler,8,dhw.settemp,set temperature,uint8 (>=0<=254),C,false,sensor.boiler_dhw_set_temperature,sensor.boiler_dhw_settemp,5,9,1,29,1 -"CS*800i, Logatherm WLW*",boiler,8,dhw.seltemp,selected temperature,uint8 (>=0<=254),C,true,number.boiler_dhw_selected_temperature,number.boiler_dhw_seltemp,5,9,1,30,1 -"CS*800i, Logatherm WLW*",boiler,8,dhw.seltemplow,selected lower temperature,uint8 (>=0<=254),C,true,number.boiler_dhw_selected_lower_temperature,number.boiler_dhw_seltemplow,5,9,1,31,1 -"CS*800i, Logatherm WLW*",boiler,8,dhw.tempecoplus,selected eco+ temperature,uint8 (>=0<=254),C,true,number.boiler_dhw_selected_eco+_temperature,number.boiler_dhw_tempecoplus,5,9,1,32,1 -"CS*800i, Logatherm WLW*",boiler,8,dhw.seltempoff,selected temperature for off,uint8 (>=0<=254),C,false,sensor.boiler_dhw_selected_temperature_for_off,sensor.boiler_dhw_seltempoff,5,9,1,33,1 -"CS*800i, Logatherm WLW*",boiler,8,dhw.seltempsingle,single charge temperature,uint8 (>=0<=254),C,true,number.boiler_dhw_single_charge_temperature,number.boiler_dhw_seltempsingle,5,9,1,34,1 -"CS*800i, Logatherm WLW*",boiler,8,dhw.solartemp,solar boiler temperature,uint16 (>=0<=3199),C,false,sensor.boiler_dhw_solar_boiler_temperature,sensor.boiler_dhw_solartemp,5,9,1/10,35,1 -"CS*800i, Logatherm WLW*",boiler,8,dhw.type,type,enum [off\|flow\|buffered flow\|buffer\|layered buffer], ,false,sensor.boiler_dhw_type,sensor.boiler_dhw_type,5,9,1,36,1 -"CS*800i, Logatherm WLW*",boiler,8,dhw.comfort,comfort,enum [hot\|eco\|intelligent], ,true,select.boiler_dhw_comfort,select.boiler_dhw_comfort,5,9,1,37,1 -"CS*800i, Logatherm WLW*",boiler,8,dhw.comfort1,comfort mode,enum [high comfort\|eco], ,true,select.boiler_dhw_comfort_mode,select.boiler_dhw_comfort1,5,9,1,38,1 -"CS*800i, Logatherm WLW*",boiler,8,dhw.flowtempoffset,flow temperature offset,uint8 (>=0<=100),C,true,number.boiler_dhw_flow_temperature_offset,number.boiler_dhw_flowtempoffset,5,9,1,39,1 -"CS*800i, Logatherm WLW*",boiler,8,dhw.chargeoptimization,charge optimization,boolean, ,true,switch.boiler_dhw_charge_optimization,switch.boiler_dhw_chargeoptimization,5,9,1,40,1 -"CS*800i, Logatherm WLW*",boiler,8,dhw.maxpower,max power,uint8 (>=0<=254),%,true,number.boiler_dhw_max_power,number.boiler_dhw_maxpower,5,9,1,41,1 -"CS*800i, Logatherm WLW*",boiler,8,dhw.maxtemp,maximum temperature,uint8 (>=0<=80),C,true,number.boiler_dhw_maximum_temperature,number.boiler_dhw_maxtemp,5,9,1,42,1 -"CS*800i, Logatherm WLW*",boiler,8,dhw.circpump,circulation pump available,boolean, ,true,switch.boiler_dhw_circulation_pump_available,switch.boiler_dhw_circpump,5,9,1,43,1 -"CS*800i, Logatherm WLW*",boiler,8,dhw.chargetype,charging type,enum [chargepump\|3-way valve], ,false,sensor.boiler_dhw_charging_type,sensor.boiler_dhw_chargetype,5,9,1,44,1 -"CS*800i, Logatherm WLW*",boiler,8,dhw.hyston,hysteresis on temperature,int8 (>=-126<=126),C,true,number.boiler_dhw_hysteresis_on_temperature,number.boiler_dhw_hyston,5,9,1,45,1 -"CS*800i, Logatherm WLW*",boiler,8,dhw.hystoff,hysteresis off temperature,int8 (>=-126<=126),C,true,number.boiler_dhw_hysteresis_off_temperature,number.boiler_dhw_hystoff,5,9,1,46,1 -"CS*800i, Logatherm WLW*",boiler,8,dhw.disinfectiontemp,disinfection temperature,uint8 (>=60<=80),C,true,number.boiler_dhw_disinfection_temperature,number.boiler_dhw_disinfectiontemp,5,9,1,47,1 -"CS*800i, Logatherm WLW*",boiler,8,dhw.circmode,circulation pump mode,enum [off\|1x3min\|2x3min\|3x3min\|4x3min\|5x3min\|6x3min\|continuous], ,true,select.boiler_dhw_circulation_pump_mode,select.boiler_dhw_circmode,5,9,1,48,1 -"CS*800i, Logatherm WLW*",boiler,8,dhw.circ,circulation active,boolean, ,true,switch.boiler_dhw_circulation_active,switch.boiler_dhw_circ,5,9,1,49,1 -"CS*800i, Logatherm WLW*",boiler,8,dhw.curtemp,current intern temperature,uint16 (>=0<=3199),C,false,sensor.boiler_dhw_current_intern_temperature,sensor.boiler_dhw_curtemp,5,9,1/10,50,1 -"CS*800i, Logatherm WLW*",boiler,8,dhw.curtemp2,current extern temperature,uint16 (>=0<=3199),C,false,sensor.boiler_dhw_current_extern_temperature,sensor.boiler_dhw_curtemp2,5,9,1/10,51,1 -"CS*800i, Logatherm WLW*",boiler,8,dhw.curflow,current tap water flow,uint8 (>=0<=25),l/min,false,sensor.boiler_dhw_current_tap_water_flow,sensor.boiler_dhw_curflow,5,9,1/10,52,1 -"CS*800i, Logatherm WLW*",boiler,8,dhw.storagetemp1,storage intern temperature,uint16 (>=0<=3199),C,false,sensor.boiler_dhw_storage_intern_temperature,sensor.boiler_dhw_storagetemp1,5,9,1/10,53,1 -"CS*800i, Logatherm WLW*",boiler,8,dhw.storagetemp2,storage extern temperature,uint16 (>=0<=3199),C,false,sensor.boiler_dhw_storage_extern_temperature,sensor.boiler_dhw_storagetemp2,5,9,1/10,54,1 -"CS*800i, Logatherm WLW*",boiler,8,dhw.activated,activated,boolean, ,true,switch.boiler_dhw_activated,switch.boiler_dhw_activated,5,9,1,55,1 -"CS*800i, Logatherm WLW*",boiler,8,dhw.onetime,one time charging,boolean, ,true,switch.boiler_dhw_one_time_charging,switch.boiler_dhw_onetime,5,9,1,56,1 -"CS*800i, Logatherm WLW*",boiler,8,dhw.disinfecting,disinfecting,boolean, ,true,switch.boiler_dhw_disinfecting,switch.boiler_dhw_disinfecting,5,9,1,57,1 -"CS*800i, Logatherm WLW*",boiler,8,dhw.charging,charging,boolean, ,false,binary_sensor.boiler_dhw_charging,binary_sensor.boiler_dhw_charging,5,9,1,58,1 -"CS*800i, Logatherm WLW*",boiler,8,dhw.recharging,recharging,boolean, ,false,binary_sensor.boiler_dhw_recharging,binary_sensor.boiler_dhw_recharging,5,9,1,59,1 -"CS*800i, Logatherm WLW*",boiler,8,dhw.tempok,temperature ok,boolean, ,false,binary_sensor.boiler_dhw_temperature_ok,binary_sensor.boiler_dhw_tempok,5,9,1,60,1 -"CS*800i, Logatherm WLW*",boiler,8,dhw.active,active,boolean, ,false,binary_sensor.boiler_dhw_active,binary_sensor.boiler_dhw_active,5,9,1,61,1 -"CS*800i, Logatherm WLW*",boiler,8,dhw.3wayvalve,3-way valve active,boolean, ,false,binary_sensor.boiler_dhw_3-way_valve_active,binary_sensor.boiler_dhw_3wayvalve,5,9,1,62,1 -"CS*800i, Logatherm WLW*",boiler,8,dhw.mixertemp,mixer temperature,uint16 (>=0<=3199),C,false,sensor.boiler_dhw_mixer_temperature,sensor.boiler_dhw_mixertemp,5,9,1/10,63,1 -"CS*800i, Logatherm WLW*",boiler,8,dhw.cylmiddletemp,cylinder middle temperature (TS3),uint16 (>=0<=3199),C,false,sensor.boiler_dhw_cylinder_middle_temperature_(TS3),sensor.boiler_dhw_cylmiddletemp,5,9,1/10,64,1 -"CS*800i, Logatherm WLW*",boiler,8,dhw.starts,starts,uint24 (>=0<=16777214), ,false,sensor.boiler_dhw_starts,sensor.boiler_dhw_starts,5,9,1,65,2 -"CS*800i, Logatherm WLW*",boiler,8,dhw.workm,active time,time (>=0<=16777214),minutes,false,sensor.boiler_dhw_active_time,sensor.boiler_dhw_workm,5,9,1,67,2 +"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,reset,reset,cmd [-\|maintenance\|error\|history\|message], ,true,sensor.boiler_reset,sensor.boiler_reset,5,0,1,0,1 +"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,heatingoff,force heating off,boolean, ,true,switch.boiler_force_heating_off,switch.boiler_heatingoff,5,0,1,1,1 +"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,heatingactive,heating active,boolean, ,false,binary_sensor.boiler_heating_active,binary_sensor.boiler_heatingactive,5,0,1,2,1 +"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,tapwateractive,tapwater active,boolean, ,false,binary_sensor.boiler_tapwater_active,binary_sensor.boiler_tapwateractive,5,0,1,3,1 +"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,selflowtemp,selected flow temperature,uint8 (>=0<=90),C,true,number.boiler_selected_flow_temperature,number.boiler_selflowtemp,5,0,1,4,1 +"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,heatingpumpmod,heating pump modulation,uint8 (>=0<=100),%,false,sensor.boiler_heating_pump_modulation,sensor.boiler_heatingpumpmod,5,0,1,5,1 +"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,outdoortemp,outside temperature,int16 (>=-3199<=3199),C,false,sensor.boiler_outside_temperature,sensor.boiler_outdoortemp,5,0,1/10,6,1 +"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,curflowtemp,current flow temperature,uint16 (>=0<=3199),C,false,sensor.boiler_current_flow_temperature,sensor.boiler_curflowtemp,5,0,1/10,7,1 +"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,rettemp,return temperature,uint16 (>=0<=3199),C,false,sensor.boiler_return_temperature,sensor.boiler_rettemp,5,0,1/10,8,1 +"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,switchtemp,mixing switch temperature,uint16 (>=0<=3199),C,false,sensor.boiler_mixing_switch_temperature,sensor.boiler_switchtemp,5,0,1/10,9,1 +"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,syspress,system pressure,uint8 (>=0<=25),bar,false,sensor.boiler_system_pressure,sensor.boiler_syspress,5,0,1/10,10,1 +"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,boiltemp,actual boiler temperature,uint16 (>=0<=3199),C,false,sensor.boiler_actual_boiler_temperature,sensor.boiler_boiltemp,5,0,1/10,11,1 +"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,headertemp,low loss header,uint16 (>=0<=3199),C,false,sensor.boiler_low_loss_header,sensor.boiler_headertemp,5,0,1/10,12,1 +"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,heatingactivated,heating activated,boolean, ,true,switch.boiler_heating_activated,switch.boiler_heatingactivated,5,0,1,13,1 +"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,heatingtemp,heating temperature,uint8 (>=0<=90),C,true,number.boiler_heating_temperature,number.boiler_heatingtemp,5,0,1,14,1 +"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,heatingpump,heating pump,boolean, ,false,binary_sensor.boiler_heating_pump,binary_sensor.boiler_heatingpump,5,0,1,15,1 +"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,pumpmodmax,boiler pump max power,uint8 (>=0<=100),%,true,number.boiler_boiler_pump_max_power,number.boiler_pumpmodmax,5,0,1,16,1 +"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,pumpmodmin,boiler pump min power,uint8 (>=0<=100),%,true,number.boiler_boiler_pump_min_power,number.boiler_pumpmodmin,5,0,1,17,1 +"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,pumpmode,boiler pump mode,enum [proportional\|deltaP-1\|deltaP-2\|deltaP-3\|deltaP-4], ,true,select.boiler_boiler_pump_mode,select.boiler_pumpmode,5,0,1,18,1 +"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,pumpcharacter,boiler pump characteristic,enum [proportional\|150mbar\|200mbar\|250mbar\|300mbar\|350mbar\|400mbar], ,true,select.boiler_boiler_pump_characteristic,select.boiler_pumpcharacter,5,0,1,19,1 +"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,pumpdelay,pump delay,uint8 (>=0<=60),minutes,true,number.boiler_pump_delay,number.boiler_pumpdelay,5,0,1,20,1 +"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,pumpontemp,pump logic temperature,uint8 (>=0<=60),C,true,number.boiler_pump_logic_temperature,number.boiler_pumpontemp,5,0,1,21,1 +"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,selburnpow,burner selected max power,uint8 (>=0<=254),%,true,number.boiler_burner_selected_max_power,number.boiler_selburnpow,5,0,1,22,1 +"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,curburnpow,burner current power,uint8 (>=0<=100),%,false,sensor.boiler_burner_current_power,sensor.boiler_curburnpow,5,0,1,23,1 +"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,burnstarts,burner starts,uint24 (>=0<=16777214), ,false,sensor.boiler_burner_starts,sensor.boiler_burnstarts,5,0,1,24,2 +"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,burnworkmin,total burner operating time,time (>=0<=16777214),minutes,false,sensor.boiler_total_burner_operating_time,sensor.boiler_burnworkmin,5,0,1,26,2 +"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,burn2workmin,burner stage 2 operating time,time (>=0<=16777214),minutes,false,sensor.boiler_burner_stage_2_operating_time,sensor.boiler_burn2workmin,5,0,1,28,2 +"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,heatworkmin,total heat operating time,time (>=0<=16777214),minutes,false,sensor.boiler_total_heat_operating_time,sensor.boiler_heatworkmin,5,0,1,30,2 +"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,heatstarts,burner starts heating,uint24 (>=0<=16777214), ,false,sensor.boiler_burner_starts_heating,sensor.boiler_heatstarts,5,0,1,32,2 +"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,ubauptime,total UBA operating time,time (>=0<=16777214),minutes,false,sensor.boiler_total_UBA_operating_time,sensor.boiler_ubauptime,5,0,1,34,2 +"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,lastcode,last error code,string, ,false,sensor.boiler_last_error_code,sensor.boiler_lastcode,5,0,1,36,28 +"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,servicecode,service code,string, ,false,sensor.boiler_service_code,sensor.boiler_servicecode,5,0,1,64,2 +"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,servicecodenumber,service code number,uint16 (>=0<=31999), ,false,sensor.boiler_service_code_number,sensor.boiler_servicecodenumber,5,0,1,66,1 +"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,maintenancemessage,maintenance message,string, ,false,sensor.boiler_maintenance_message,sensor.boiler_maintenancemessage,5,0,1,67,2 +"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,maintenance,maintenance scheduled,enum [off\|time\|date\|manual], ,true,select.boiler_maintenance_scheduled,select.boiler_maintenance,5,0,1,69,1 +"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,maintenancetime,time to next maintenance,uint16 (>=0<=31999),hours,true,number.boiler_time_to_next_maintenance,number.boiler_maintenancetime,5,0,1,70,1 +"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,maintenancedate,next maintenance date,string, ,true,sensor.boiler_next_maintenance_date,sensor.boiler_maintenancedate,5,0,1,71,6 +"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,emergencyops,emergency operation,boolean, ,true,switch.boiler_emergency_operation,switch.boiler_emergencyops,5,0,1,77,1 +"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,emergencytemp,emergency temperature,uint8 (>=15<=70),C,true,number.boiler_emergency_temperature,number.boiler_emergencytemp,5,0,1,78,1 +"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,pc0flow,Flow PC0,int16 (>=-31999<=31999),l/h,false,sensor.boiler_Flow_PC0,sensor.boiler_pc0flow,5,0,1,79,1 +"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,pc1flow,Flow PC1,int16 (>=-31999<=31999),l/h,false,sensor.boiler_Flow_PC1,sensor.boiler_pc1flow,5,0,1,80,1 +"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,pc1on,PC1,boolean, ,false,binary_sensor.boiler_PC1,binary_sensor.boiler_pc1on,5,0,1,81,1 +"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,pc1rate,PC1 rate,uint8 (>=0<=100),%,false,sensor.boiler_PC1_rate,sensor.boiler_pc1rate,5,0,1,82,1 +"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,nrgtotal,total energy,uint24 (>=0<=167772),kWh,false,sensor.boiler_total_energy,sensor.boiler_nrgtotal,5,0,1/100,83,2 +"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,dhw.nrg,energy,uint24 (>=0<=167772),kWh,false,sensor.boiler_dhw_energy,sensor.boiler_dhw_nrg,5,9,1/100,0,2 +"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,nrgheat,energy heating,uint24 (>=0<=167772),kWh,false,sensor.boiler_energy_heating,sensor.boiler_nrgheat,5,0,1/100,85,2 +"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,nrgcool,energy cooling,uint24 (>=0<=167772),kWh,false,sensor.boiler_energy_cooling,sensor.boiler_nrgcool,5,0,1/100,87,2 +"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,metertotal,meter total,uint24 (>=0<=167772),kWh,false,sensor.boiler_meter_total,sensor.boiler_metertotal,5,0,1/100,89,2 +"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,metercomp,meter compressor,uint24 (>=0<=167772),kWh,false,sensor.boiler_meter_compressor,sensor.boiler_metercomp,5,0,1/100,91,2 +"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,metereheat,meter e-heater,uint24 (>=0<=167772),kWh,false,sensor.boiler_meter_e-heater,sensor.boiler_metereheat,5,0,1/100,93,2 +"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,meterheat,meter heating,uint24 (>=0<=167772),kWh,false,sensor.boiler_meter_heating,sensor.boiler_meterheat,5,0,1/100,95,2 +"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,metercool,meter cooling,uint24 (>=0<=167772),kWh,false,sensor.boiler_meter_cooling,sensor.boiler_metercool,5,0,1/100,97,2 +"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,dhw.meter,meter,uint24 (>=0<=167772),kWh,false,sensor.boiler_dhw_meter,sensor.boiler_dhw_meter,5,9,1/100,2,2 +"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,uptimetotal,heatpump total uptime,time (>=0<=279620),minutes,false,sensor.boiler_heatpump_total_uptime,sensor.boiler_uptimetotal,5,0,1/60,99,2 +"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,uptimecontrol,total operating time heat,time (>=0<=279620),minutes,false,sensor.boiler_total_operating_time_heat,sensor.boiler_uptimecontrol,5,0,1/60,101,2 +"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,uptimecompheating,operating time compressor heating,time (>=0<=279620),minutes,false,sensor.boiler_operating_time_compressor_heating,sensor.boiler_uptimecompheating,5,0,1/60,103,2 +"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,uptimecompcooling,operating time compressor cooling,time (>=0<=279620),minutes,false,sensor.boiler_operating_time_compressor_cooling,sensor.boiler_uptimecompcooling,5,0,1/60,105,2 +"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,dhw.uptimecomp,operating time compressor,time (>=0<=279620),minutes,false,sensor.boiler_dhw_operating_time_compressor,sensor.boiler_dhw_uptimecomp,5,9,1/60,4,2 +"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,uptimecomppool,operating time compressor pool,time (>=0<=279620),minutes,false,sensor.boiler_operating_time_compressor_pool,sensor.boiler_uptimecomppool,5,0,1/60,107,2 +"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,totalcompstarts,total compressor control starts,uint24 (>=0<=16777214), ,false,sensor.boiler_total_compressor_control_starts,sensor.boiler_totalcompstarts,5,0,1,109,2 +"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,heatingstarts,heating control starts,uint24 (>=0<=16777214), ,false,sensor.boiler_heating_control_starts,sensor.boiler_heatingstarts,5,0,1,111,2 +"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,coolingstarts,cooling control starts,uint24 (>=0<=16777214), ,false,sensor.boiler_cooling_control_starts,sensor.boiler_coolingstarts,5,0,1,113,2 +"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,dhw.startshp,starts hp,uint24 (>=0<=16777214), ,false,sensor.boiler_dhw_starts_hp,sensor.boiler_dhw_startshp,5,9,1,6,2 +"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,poolstarts,pool control starts,uint24 (>=0<=16777214), ,false,sensor.boiler_pool_control_starts,sensor.boiler_poolstarts,5,0,1,115,2 +"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,nrgconstotal,total energy consumption,uint24 (>=0<=16777214),kWh,false,sensor.boiler_total_energy_consumption,sensor.boiler_nrgconstotal,5,0,1,117,2 +"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,nrgconscomptotal,total energy consumption compressor,uint24 (>=0<=16777214),kWh,false,sensor.boiler_total_energy_consumption_compressor,sensor.boiler_nrgconscomptotal,5,0,1,119,2 +"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,nrgconscompheating,energy consumption compressor heating,uint24 (>=0<=16777214),kWh,false,sensor.boiler_energy_consumption_compressor_heating,sensor.boiler_nrgconscompheating,5,0,1,121,2 +"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,dhw.nrgconscomp,energy consumption compressor,uint24 (>=0<=16777214),kWh,false,sensor.boiler_dhw_energy_consumption_compressor,sensor.boiler_dhw_nrgconscomp,5,9,1,8,2 +"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,nrgconscompcooling,energy consumption compressor cooling,uint24 (>=0<=16777214),kWh,false,sensor.boiler_energy_consumption_compressor_cooling,sensor.boiler_nrgconscompcooling,5,0,1,123,2 +"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,nrgconscomppool,energy consumption compressor pool,uint24 (>=0<=16777214),kWh,false,sensor.boiler_energy_consumption_compressor_pool,sensor.boiler_nrgconscomppool,5,0,1,125,2 +"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,auxelecheatnrgconstotal,total aux elec. heater energy consumption,uint24 (>=0<=16777214),kWh,false,sensor.boiler_total_aux_elec._heater_energy_consumption,sensor.boiler_auxelecheatnrgconstotal,5,0,1,127,2 +"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,auxelecheatnrgconsheating,aux elec. heater energy consumption heating,uint24 (>=0<=16777214),kWh,false,sensor.boiler_aux_elec._heater_energy_consumption_heating,sensor.boiler_auxelecheatnrgconsheating,5,0,1,129,2 +"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,dhw.auxelecheatnrgcons,aux elec. heater energy consumption,uint24 (>=0<=16777214),kWh,false,sensor.boiler_dhw_aux_elec._heater_energy_consumption,sensor.boiler_dhw_auxelecheatnrgcons,5,9,1,10,2 +"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,auxelecheatnrgconspool,aux elec. heater energy consumption pool,uint24 (>=0<=16777214),kWh,false,sensor.boiler_aux_elec._heater_energy_consumption_pool,sensor.boiler_auxelecheatnrgconspool,5,0,1,131,2 +"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,nrgsupptotal,total energy supplied,uint24 (>=0<=16777214),kWh,false,sensor.boiler_total_energy_supplied,sensor.boiler_nrgsupptotal,5,0,1,133,2 +"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,nrgsuppheating,total energy supplied heating,uint24 (>=0<=16777214),kWh,false,sensor.boiler_total_energy_supplied_heating,sensor.boiler_nrgsuppheating,5,0,1,135,2 +"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,dhw.nrgsupp,total energy warm supplied,uint24 (>=0<=16777214),kWh,false,sensor.boiler_dhw_total_energy_warm_supplied,sensor.boiler_dhw_nrgsupp,5,9,1,12,2 +"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,nrgsuppcooling,total energy supplied cooling,uint24 (>=0<=16777214),kWh,false,sensor.boiler_total_energy_supplied_cooling,sensor.boiler_nrgsuppcooling,5,0,1,137,2 +"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,nrgsupppool,total energy supplied pool,uint24 (>=0<=16777214),kWh,false,sensor.boiler_total_energy_supplied_pool,sensor.boiler_nrgsupppool,5,0,1,139,2 +"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,hppower,compressor power output,uint16 (>=0<=3199),kW,false,sensor.boiler_compressor_power_output,sensor.boiler_hppower,5,0,1/10,141,1 +"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,hpmaxpower,compressor max power,uint8 (>=0<=100),%,true,number.boiler_compressor_max_power,number.boiler_hpmaxpower,5,0,1,142,1 +"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,pvmaxcomp,pv compressor max power,uint8 (>=0<=25),kW,true,number.boiler_pv_compressor_max_power,number.boiler_pvmaxcomp,5,0,1/10,143,1 +"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,powerreduction,power reduction,uint8 (>=30<=60),%,true,number.boiler_power_reduction,number.boiler_powerreduction,5,0,10,144,1 +"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,hpsetdiffpress,set differential pressure,uint8 (>=150<=750),mbar,true,number.boiler_set_differential_pressure,number.boiler_hpsetdiffpress,5,0,50,145,1 +"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,hpcompon,hp compressor,boolean, ,false,binary_sensor.boiler_hp_compressor,binary_sensor.boiler_hpcompon,5,0,1,146,1 +"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,hpactivity,compressor activity,enum [off\|heating\|cooling\|hot water\|pool\|pool heating\|defrost\|compressor alarm], ,false,sensor.boiler_compressor_activity,sensor.boiler_hpactivity,5,0,1,147,1 +"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,hpbrinepumpspd,brine pump speed,uint8 (>=0<=100),%,false,sensor.boiler_brine_pump_speed,sensor.boiler_hpbrinepumpspd,5,0,1,148,1 +"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,hpswitchvalve,switch valve,boolean, ,false,binary_sensor.boiler_switch_valve,binary_sensor.boiler_hpswitchvalve,5,0,1,149,1 +"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,hpcompspd,compressor speed,uint8 (>=0<=100),%,false,sensor.boiler_compressor_speed,sensor.boiler_hpcompspd,5,0,1,150,1 +"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,hpcircspd,circulation pump speed,uint8 (>=0<=100),%,false,sensor.boiler_circulation_pump_speed,sensor.boiler_hpcircspd,5,0,1,151,1 +"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,hpbrinein,brine in/evaporator,int16 (>=-3199<=3199),C,false,sensor.boiler_brine_in/evaporator,sensor.boiler_hpbrinein,5,0,1/10,152,1 +"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,hpbrineout,brine out/condenser,int16 (>=-3199<=3199),C,false,sensor.boiler_brine_out/condenser,sensor.boiler_hpbrineout,5,0,1/10,153,1 +"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,hptc0,heat carrier return (TC0),int16 (>=-3199<=3199),C,false,sensor.boiler_heat_carrier_return_(TC0),sensor.boiler_hptc0,5,0,1/10,154,1 +"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,hptc1,heat carrier forward (TC1),int16 (>=-3199<=3199),C,false,sensor.boiler_heat_carrier_forward_(TC1),sensor.boiler_hptc1,5,0,1/10,155,1 +"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,hptc3,condenser temperature (TC3),int16 (>=-3199<=3199),C,false,sensor.boiler_condenser_temperature_(TC3),sensor.boiler_hptc3,5,0,1/10,156,1 +"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,hptr1,compressor temperature (TR1),int16 (>=-3199<=3199),C,false,sensor.boiler_compressor_temperature_(TR1),sensor.boiler_hptr1,5,0,1/10,157,1 +"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,hptr3,refrigerant temperature liquid side (condenser output) (TR3),int16 (>=-3199<=3199),C,false,sensor.boiler_refrigerant_temperature_liquid_side_(condenser_output)_(TR3),sensor.boiler_hptr3,5,0,1/10,158,1 +"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,hptr4,evaporator inlet temperature (TR4),int16 (>=-3199<=3199),C,false,sensor.boiler_evaporator_inlet_temperature_(TR4),sensor.boiler_hptr4,5,0,1/10,159,1 +"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,hptr5,compressor inlet temperature (TR5),int16 (>=-3199<=3199),C,false,sensor.boiler_compressor_inlet_temperature_(TR5),sensor.boiler_hptr5,5,0,1/10,160,1 +"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,hptr6,compressor outlet temperature (TR6),int16 (>=-3199<=3199),C,false,sensor.boiler_compressor_outlet_temperature_(TR6),sensor.boiler_hptr6,5,0,1/10,161,1 +"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,hptr7,refrigerant temperature gas side (condenser input) (TR7),int16 (>=-3199<=3199),C,false,sensor.boiler_refrigerant_temperature_gas_side_(condenser_input)_(TR7),sensor.boiler_hptr7,5,0,1/10,162,1 +"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,hptl2,air inlet temperature (TL2),int16 (>=-3199<=3199),C,false,sensor.boiler_air_inlet_temperature_(TL2),sensor.boiler_hptl2,5,0,1/10,163,1 +"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,hppl1,low pressure side temperature (PL1),int16 (>=-3199<=3199),C,false,sensor.boiler_low_pressure_side_temperature_(PL1),sensor.boiler_hppl1,5,0,1/10,164,1 +"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,hpph1,high pressure side temperature (PH1),int16 (>=-3199<=3199),C,false,sensor.boiler_high_pressure_side_temperature_(PH1),sensor.boiler_hpph1,5,0,1/10,165,1 +"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,hpta4,drain pan temp (TA4),int16 (>=-3199<=3199),C,false,sensor.boiler_drain_pan_temp_(TA4),sensor.boiler_hpta4,5,0,1/10,166,1 +"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,hptw1,reservoir temp (TW1),int16 (>=-3199<=3199),C,false,sensor.boiler_reservoir_temp_(TW1),sensor.boiler_hptw1,5,0,1/10,167,1 +"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,poolsettemp,pool set temperature,uint8 (>=0<=127),C,true,number.boiler_pool_set_temperature,number.boiler_poolsettemp,5,0,1/2,168,1 +"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,hp4way,4-way valve (VR4),enum [cooling & defrost\|heating & dhw], ,false,sensor.boiler_4-way_valve_(VR4),sensor.boiler_hp4way,5,0,1,169,1 +"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,hpin1,input 1 state,boolean, ,false,binary_sensor.boiler_input_1_state,binary_sensor.boiler_hpin1,5,0,1,170,1 +"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,hpin1opt,input 1 options,string, ,true,sensor.boiler_input_1_options,sensor.boiler_hpin1opt,5,0,1,171,8 +"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,hpin2,input 2 state,boolean, ,false,binary_sensor.boiler_input_2_state,binary_sensor.boiler_hpin2,5,0,1,179,1 +"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,hpin2opt,input 2 options,string, ,true,sensor.boiler_input_2_options,sensor.boiler_hpin2opt,5,0,1,180,8 +"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,hpin3,input 3 state,boolean, ,false,binary_sensor.boiler_input_3_state,binary_sensor.boiler_hpin3,5,0,1,188,1 +"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,hpin3opt,input 3 options,string, ,true,sensor.boiler_input_3_options,sensor.boiler_hpin3opt,5,0,1,189,8 +"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,hpin4,input 4 state,boolean, ,false,binary_sensor.boiler_input_4_state,binary_sensor.boiler_hpin4,5,0,1,197,1 +"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,hpin4opt,input 4 options,string, ,true,sensor.boiler_input_4_options,sensor.boiler_hpin4opt,5,0,1,198,8 +"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,maxheatcomp,heat limit compressor,enum [0 kW\|3 kW\|6 kW\|9 kW], ,true,select.boiler_heat_limit_compressor,select.boiler_maxheatcomp,5,0,1,206,1 +"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,maxheatheat,heat limit heating,enum [3 kW\|6 kW\|9 kW], ,true,select.boiler_heat_limit_heating,select.boiler_maxheatheat,5,0,1,207,1 +"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,dhw.maxheat,heat limit,enum [3 kW\|6 kW\|9 kW], ,true,select.boiler_dhw_heat_limit,select.boiler_dhw_maxheat,5,9,1,14,1 +"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,auxheatersource,aux heater source,enum [not installed\|electric heater\|exclusive\|parallel\|hybrid], ,true,select.boiler_aux_heater_source,select.boiler_auxheatersource,5,0,1,208,1 +"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,pvcooling,cooling only with PV,boolean, ,true,switch.boiler_cooling_only_with_PV,switch.boiler_pvcooling,5,0,1,209,1 +"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,auxheateronly,aux heater only,boolean, ,true,switch.boiler_aux_heater_only,switch.boiler_auxheateronly,5,0,1,210,1 +"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,auxheateroff,disable aux heater,boolean, ,true,switch.boiler_disable_aux_heater,switch.boiler_auxheateroff,5,0,1,211,1 +"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,auxheaterstatus,aux heater status,enum [off\|heating\|cooling\|hot water\|pool\|pool heating\|defrost\|compressor alarm], ,false,sensor.boiler_aux_heater_status,sensor.boiler_auxheaterstatus,5,0,1,212,1 +"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,auxheaterlevel,aux heater level,uint8 (>=0<=100),%,false,sensor.boiler_aux_heater_level,sensor.boiler_auxheaterlevel,5,0,1,213,1 +"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,auxheaterdelay,aux heater on delay,uint16 (>=10<=1000),K*min,true,number.boiler_aux_heater_on_delay,number.boiler_auxheaterdelay,5,0,10,214,1 +"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,auxmaxlimit,aux heater max limit,uint8 (>=0<=10),K,true,number.boiler_aux_heater_max_limit,number.boiler_auxmaxlimit,5,0,1/10,215,1 +"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,auxlimitstart,aux heater limit start,uint8 (>=0<=10),K,true,number.boiler_aux_heater_limit_start,number.boiler_auxlimitstart,5,0,1/10,216,1 +"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,auxheatrmode,aux heater mode,enum [eco\|comfort], ,true,select.boiler_aux_heater_mode,select.boiler_auxheatrmode,5,0,1,217,1 +"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,hphystheat,on/off hyst heat,uint16 (>=50<=1500),K*min,true,number.boiler_on/off_hyst_heat,number.boiler_hphystheat,5,0,5,218,1 +"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,hphystcool,on/off hyst cool,uint16 (>=50<=1500),K*min,true,number.boiler_on/off_hyst_cool,number.boiler_hphystcool,5,0,5,219,1 +"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,hphystpool,on/off hyst pool,uint16 (>=50<=1500),K*min,true,number.boiler_on/off_hyst_pool,number.boiler_hphystpool,5,0,5,220,1 +"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,silentmode,silent mode,enum [off\|auto\|on], ,true,select.boiler_silent_mode,select.boiler_silentmode,5,0,1,221,1 +"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,silentfrom,silent mode from,uint8 (>=0<=3810),minutes,true,number.boiler_silent_mode_from,number.boiler_silentfrom,5,0,15,222,1 +"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,silentto,silent mode to,uint8 (>=0<=3810),minutes,true,number.boiler_silent_mode_to,number.boiler_silentto,5,0,15,223,1 +"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,mintempsilent,min outside temp for silent mode,int8 (>=-126<=126),C,true,number.boiler_min_outside_temp_for_silent_mode,number.boiler_mintempsilent,5,0,1,224,1 +"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,tempparmode,outside temp parallel mode,int8 (>=-126<=126),C,true,number.boiler_outside_temp_parallel_mode,number.boiler_tempparmode,5,0,1,225,1 +"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,auxheatmix,aux heater mixing valve,int8 (>=-100<=100),%,false,sensor.boiler_aux_heater_mixing_valve,sensor.boiler_auxheatmix,5,0,1,226,1 +"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,tempdiffheat,temp diff TC3/TC0 heat,uint8 (>=2<=10),K,true,number.boiler_temp_diff_TC3/TC0_heat,number.boiler_tempdiffheat,5,0,1/10,227,1 +"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,tempdiffcool,temp diff TC3/TC0 cool,uint8 (>=2<=10),K,true,number.boiler_temp_diff_TC3/TC0_cool,number.boiler_tempdiffcool,5,0,1/10,228,1 +"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,vpcooling,valve/pump cooling,boolean, ,true,switch.boiler_valve/pump_cooling,switch.boiler_vpcooling,5,0,1,229,1 +"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,heatcable,heating cable,boolean, ,true,switch.boiler_heating_cable,switch.boiler_heatcable,5,0,1,230,1 +"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,vc0valve,VC0 valve,boolean, ,true,switch.boiler_VC0_valve,switch.boiler_vc0valve,5,0,1,231,1 +"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,primepump,primary heatpump,boolean, ,true,switch.boiler_primary_heatpump,switch.boiler_primepump,5,0,1,232,1 +"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,primepumpmod,primary heatpump modulation,uint8 (>=0<=100),%,true,number.boiler_primary_heatpump_modulation,number.boiler_primepumpmod,5,0,1,233,1 +"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,hp3way,3-way valve,boolean, ,true,switch.boiler_3-way_valve,switch.boiler_hp3way,5,0,1,234,1 +"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,elheatstep1,el. heater step 1,boolean, ,true,switch.boiler_el._heater_step_1,switch.boiler_elheatstep1,5,0,1,235,1 +"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,elheatstep2,el. heater step 2,boolean, ,true,switch.boiler_el._heater_step_2,switch.boiler_elheatstep2,5,0,1,236,1 +"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,elheatstep3,el. heater step 3,boolean, ,true,switch.boiler_el._heater_step_3,switch.boiler_elheatstep3,5,0,1,237,1 +"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,hpea0,condensate reservoir heating (EA0),boolean, ,false,binary_sensor.boiler_condensate_reservoir_heating_(EA0),binary_sensor.boiler_hpea0,5,0,1,238,1 +"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,hppumpmode,primary heatpump mode,enum [auto\|continuous], ,true,select.boiler_primary_heatpump_mode,select.boiler_hppumpmode,5,0,1,239,1 +"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,fan,fan,uint8 (>=20<=100),%,true,number.boiler_fan,number.boiler_fan,5,0,1,240,1 +"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,shutdown,shutdown,cmd [off\|on], ,true,sensor.boiler_shutdown,sensor.boiler_shutdown,5,0,1,241,1 +"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,hpcurrpower,compressor current power,uint16 (>=0<=31999),W,false,sensor.boiler_compressor_current_power,sensor.boiler_hpcurrpower,5,0,1,242,1 +"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,hppowerlimit,power limit,uint16 (>=0<=31999),W,true,number.boiler_power_limit,number.boiler_hppowerlimit,5,0,1,243,1 +"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,dhw.alternatingop,alternating operation,boolean, ,true,switch.boiler_dhw_alternating_operation,switch.boiler_dhw_alternatingop,5,9,1,15,1 +"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,dhw.altopprioheat,prioritise heating during dhw,uint8 (>=20<=120),minutes,true,number.boiler_dhw_prioritise_heating_during_dhw,number.boiler_dhw_altopprioheat,5,9,1,16,1 +"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,dhw.altopprio,prioritise dhw during heating,uint8 (>=30<=120),minutes,true,number.boiler_dhw_prioritise_dhw_during_heating,number.boiler_dhw_altopprio,5,9,1,17,1 +"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,dhw.comfoff,comfort switch off,uint8 (>=15<=65),C,true,number.boiler_dhw_comfort_switch_off,number.boiler_dhw_comfoff,5,9,1,18,1 +"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,dhw.ecooff,eco switch off,uint8 (>=15<=65),C,true,number.boiler_dhw_eco_switch_off,number.boiler_dhw_ecooff,5,9,1,19,1 +"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,dhw.ecoplusoff,eco+ switch off,uint8 (>=48<=63),C,true,number.boiler_dhw_eco+_switch_off,number.boiler_dhw_ecoplusoff,5,9,1,20,1 +"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,dhw.comfdiff,comfort diff,uint8 (>=6<=12),K,true,number.boiler_dhw_comfort_diff,number.boiler_dhw_comfdiff,5,9,1,21,1 +"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,dhw.ecodiff,eco diff,uint8 (>=6<=12),K,true,number.boiler_dhw_eco_diff,number.boiler_dhw_ecodiff,5,9,1,22,1 +"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,dhw.ecoplusdiff,eco+ diff,uint8 (>=6<=12),K,true,number.boiler_dhw_eco+_diff,number.boiler_dhw_ecoplusdiff,5,9,1,23,1 +"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,dhw.comfstop,comfort stop temp,uint8 (>=0<=254),C,true,number.boiler_dhw_comfort_stop_temp,number.boiler_dhw_comfstop,5,9,1,24,1 +"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,dhw.ecostop,eco stop temp,uint8 (>=0<=254),C,true,number.boiler_dhw_eco_stop_temp,number.boiler_dhw_ecostop,5,9,1,25,1 +"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,dhw.ecoplusstop,eco+ stop temp,uint8 (>=0<=254),C,true,number.boiler_dhw_eco+_stop_temp,number.boiler_dhw_ecoplusstop,5,9,1,26,1 +"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,dhw.hpcircpump,circulation pump available during dhw,boolean, ,true,switch.boiler_dhw_circulation_pump_available_during_dhw,switch.boiler_dhw_hpcircpump,5,9,1,27,1 +"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,dhw.tapactivated,turn on/off,boolean, ,true,switch.boiler_dhw_turn_on/off,switch.boiler_dhw_tapactivated,5,9,1,28,1 +"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,dhw.settemp,set temperature,uint8 (>=0<=254),C,false,sensor.boiler_dhw_set_temperature,sensor.boiler_dhw_settemp,5,9,1,29,1 +"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,dhw.seltemp,selected temperature,uint8 (>=0<=254),C,true,number.boiler_dhw_selected_temperature,number.boiler_dhw_seltemp,5,9,1,30,1 +"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,dhw.seltemplow,selected lower temperature,uint8 (>=0<=254),C,true,number.boiler_dhw_selected_lower_temperature,number.boiler_dhw_seltemplow,5,9,1,31,1 +"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,dhw.tempecoplus,selected eco+ temperature,uint8 (>=0<=254),C,true,number.boiler_dhw_selected_eco+_temperature,number.boiler_dhw_tempecoplus,5,9,1,32,1 +"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,dhw.seltempoff,selected temperature for off,uint8 (>=0<=254),C,false,sensor.boiler_dhw_selected_temperature_for_off,sensor.boiler_dhw_seltempoff,5,9,1,33,1 +"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,dhw.seltempsingle,single charge temperature,uint8 (>=0<=254),C,true,number.boiler_dhw_single_charge_temperature,number.boiler_dhw_seltempsingle,5,9,1,34,1 +"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,dhw.solartemp,solar boiler temperature,uint16 (>=0<=3199),C,false,sensor.boiler_dhw_solar_boiler_temperature,sensor.boiler_dhw_solartemp,5,9,1/10,35,1 +"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,dhw.type,type,enum [off\|flow\|buffered flow\|buffer\|layered buffer], ,false,sensor.boiler_dhw_type,sensor.boiler_dhw_type,5,9,1,36,1 +"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,dhw.comfort,comfort,enum [hot\|eco\|intelligent], ,true,select.boiler_dhw_comfort,select.boiler_dhw_comfort,5,9,1,37,1 +"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,dhw.comfort1,comfort mode,enum [high comfort\|eco], ,true,select.boiler_dhw_comfort_mode,select.boiler_dhw_comfort1,5,9,1,38,1 +"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,dhw.flowtempoffset,flow temperature offset,uint8 (>=0<=100),C,true,number.boiler_dhw_flow_temperature_offset,number.boiler_dhw_flowtempoffset,5,9,1,39,1 +"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,dhw.chargeoptimization,charge optimization,boolean, ,true,switch.boiler_dhw_charge_optimization,switch.boiler_dhw_chargeoptimization,5,9,1,40,1 +"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,dhw.maxpower,max power,uint8 (>=0<=254),%,true,number.boiler_dhw_max_power,number.boiler_dhw_maxpower,5,9,1,41,1 +"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,dhw.maxtemp,maximum temperature,uint8 (>=0<=80),C,true,number.boiler_dhw_maximum_temperature,number.boiler_dhw_maxtemp,5,9,1,42,1 +"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,dhw.circpump,circulation pump available,boolean, ,true,switch.boiler_dhw_circulation_pump_available,switch.boiler_dhw_circpump,5,9,1,43,1 +"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,dhw.chargetype,charging type,enum [chargepump\|3-way valve], ,false,sensor.boiler_dhw_charging_type,sensor.boiler_dhw_chargetype,5,9,1,44,1 +"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,dhw.hyston,hysteresis on temperature,int8 (>=-126<=126),C,true,number.boiler_dhw_hysteresis_on_temperature,number.boiler_dhw_hyston,5,9,1,45,1 +"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,dhw.hystoff,hysteresis off temperature,int8 (>=-126<=126),C,true,number.boiler_dhw_hysteresis_off_temperature,number.boiler_dhw_hystoff,5,9,1,46,1 +"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,dhw.disinfectiontemp,disinfection temperature,uint8 (>=60<=80),C,true,number.boiler_dhw_disinfection_temperature,number.boiler_dhw_disinfectiontemp,5,9,1,47,1 +"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,dhw.circmode,circulation pump mode,enum [off\|1x3min\|2x3min\|3x3min\|4x3min\|5x3min\|6x3min\|continuous], ,true,select.boiler_dhw_circulation_pump_mode,select.boiler_dhw_circmode,5,9,1,48,1 +"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,dhw.circ,circulation active,boolean, ,true,switch.boiler_dhw_circulation_active,switch.boiler_dhw_circ,5,9,1,49,1 +"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,dhw.curtemp,current intern temperature,uint16 (>=0<=3199),C,false,sensor.boiler_dhw_current_intern_temperature,sensor.boiler_dhw_curtemp,5,9,1/10,50,1 +"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,dhw.curtemp2,current extern temperature,uint16 (>=0<=3199),C,false,sensor.boiler_dhw_current_extern_temperature,sensor.boiler_dhw_curtemp2,5,9,1/10,51,1 +"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,dhw.curflow,current tap water flow,uint8 (>=0<=25),l/min,false,sensor.boiler_dhw_current_tap_water_flow,sensor.boiler_dhw_curflow,5,9,1/10,52,1 +"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,dhw.storagetemp1,storage intern temperature,uint16 (>=0<=3199),C,false,sensor.boiler_dhw_storage_intern_temperature,sensor.boiler_dhw_storagetemp1,5,9,1/10,53,1 +"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,dhw.storagetemp2,storage extern temperature,uint16 (>=0<=3199),C,false,sensor.boiler_dhw_storage_extern_temperature,sensor.boiler_dhw_storagetemp2,5,9,1/10,54,1 +"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,dhw.activated,activated,boolean, ,true,switch.boiler_dhw_activated,switch.boiler_dhw_activated,5,9,1,55,1 +"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,dhw.onetime,one time charging,boolean, ,true,switch.boiler_dhw_one_time_charging,switch.boiler_dhw_onetime,5,9,1,56,1 +"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,dhw.disinfecting,disinfecting,boolean, ,true,switch.boiler_dhw_disinfecting,switch.boiler_dhw_disinfecting,5,9,1,57,1 +"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,dhw.charging,charging,boolean, ,false,binary_sensor.boiler_dhw_charging,binary_sensor.boiler_dhw_charging,5,9,1,58,1 +"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,dhw.recharging,recharging,boolean, ,false,binary_sensor.boiler_dhw_recharging,binary_sensor.boiler_dhw_recharging,5,9,1,59,1 +"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,dhw.tempok,temperature ok,boolean, ,false,binary_sensor.boiler_dhw_temperature_ok,binary_sensor.boiler_dhw_tempok,5,9,1,60,1 +"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,dhw.active,active,boolean, ,false,binary_sensor.boiler_dhw_active,binary_sensor.boiler_dhw_active,5,9,1,61,1 +"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,dhw.3wayvalve,3-way valve active,boolean, ,false,binary_sensor.boiler_dhw_3-way_valve_active,binary_sensor.boiler_dhw_3wayvalve,5,9,1,62,1 +"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,dhw.chargepump,charge pump,boolean, ,false,binary_sensor.boiler_dhw_charge_pump,binary_sensor.boiler_dhw_chargepump,5,9,1,63,1 +"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,dhw.mixertemp,mixer temperature,uint16 (>=0<=3199),C,false,sensor.boiler_dhw_mixer_temperature,sensor.boiler_dhw_mixertemp,5,9,1/10,64,1 +"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,dhw.cylmiddletemp,cylinder middle temperature (TS3),uint16 (>=0<=3199),C,false,sensor.boiler_dhw_cylinder_middle_temperature_(TS3),sensor.boiler_dhw_cylmiddletemp,5,9,1/10,65,1 +"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,dhw.starts,starts,uint24 (>=0<=16777214), ,false,sensor.boiler_dhw_starts,sensor.boiler_dhw_starts,5,9,1,66,2 +"CS5800i, CS6800i, WLW176i, WLW186i",boiler,8,dhw.workm,active time,time (>=0<=16777214),minutes,false,sensor.boiler_dhw_active_time,sensor.boiler_dhw_workm,5,9,1,68,2 "C1200W",boiler,12,reset,reset,cmd [-\|maintenance\|error\|history\|message], ,true,sensor.boiler_reset,sensor.boiler_reset,5,0,1,0,1 "C1200W",boiler,12,heatingoff,force heating off,boolean, ,true,switch.boiler_force_heating_off,switch.boiler_heatingoff,5,0,1,1,1 "C1200W",boiler,12,heatingactive,heating active,boolean, ,false,binary_sensor.boiler_heating_active,binary_sensor.boiler_heatingactive,5,0,1,2,1 @@ -274,9 +275,9 @@ device name,device type,product id,shortname,fullname,type [options...] \| (min/ "C1200W",boiler,12,meterheat,meter heating,uint24 (>=0<=1677721),kWh,false,sensor.boiler_meter_heating,sensor.boiler_meterheat,5,0,1/10,95,2 "C1200W",boiler,12,dhw.meter,meter,uint24 (>=0<=1677721),kWh,false,sensor.boiler_dhw_meter,sensor.boiler_dhw_meter,5,9,1/10,2,2 "C1200W",boiler,12,gasmeterheat,gas meter heating,uint24 (>=0<=1677721),kWh,false,sensor.boiler_gas_meter_heating,sensor.boiler_gasmeterheat,5,0,1/10,266,2 -"C1200W",boiler,12,dhw.gasmeter,gas meter,uint24 (>=0<=1677721),kWh,false,sensor.boiler_dhw_gas_meter,sensor.boiler_dhw_gasmeter,5,9,1/10,69,2 +"C1200W",boiler,12,dhw.gasmeter,gas meter,uint24 (>=0<=1677721),kWh,false,sensor.boiler_dhw_gas_meter,sensor.boiler_dhw_gasmeter,5,9,1/10,70,2 "C1200W",boiler,12,nrgheat2,energy heating 2,uint24 (>=0<=1677721),kWh,false,sensor.boiler_energy_heating_2,sensor.boiler_nrgheat2,5,0,1/10,268,2 -"C1200W",boiler,12,dhw.nrg2,energy 2,uint24 (>=0<=1677721),kWh,false,sensor.boiler_dhw_energy_2,sensor.boiler_dhw_nrg2,5,9,1/10,71,2 +"C1200W",boiler,12,dhw.nrg2,energy 2,uint24 (>=0<=1677721),kWh,false,sensor.boiler_dhw_energy_2,sensor.boiler_dhw_nrg2,5,9,1/10,72,2 "C1200W",boiler,12,dhw.tapactivated,turn on/off,boolean, ,true,switch.boiler_dhw_turn_on/off,switch.boiler_dhw_tapactivated,5,9,1,28,1 "C1200W",boiler,12,dhw.settemp,set temperature,uint8 (>=0<=254),C,false,sensor.boiler_dhw_set_temperature,sensor.boiler_dhw_settemp,5,9,1,29,1 "C1200W",boiler,12,dhw.seltemp,selected temperature,uint8 (>=0<=254),C,true,number.boiler_dhw_selected_temperature,number.boiler_dhw_seltemp,5,9,1,30,1 @@ -312,10 +313,11 @@ device name,device type,product id,shortname,fullname,type [options...] \| (min/ "C1200W",boiler,12,dhw.tempok,temperature ok,boolean, ,false,binary_sensor.boiler_dhw_temperature_ok,binary_sensor.boiler_dhw_tempok,5,9,1,60,1 "C1200W",boiler,12,dhw.active,active,boolean, ,false,binary_sensor.boiler_dhw_active,binary_sensor.boiler_dhw_active,5,9,1,61,1 "C1200W",boiler,12,dhw.3wayvalve,3-way valve active,boolean, ,false,binary_sensor.boiler_dhw_3-way_valve_active,binary_sensor.boiler_dhw_3wayvalve,5,9,1,62,1 -"C1200W",boiler,12,dhw.mixertemp,mixer temperature,uint16 (>=0<=3199),C,false,sensor.boiler_dhw_mixer_temperature,sensor.boiler_dhw_mixertemp,5,9,1/10,63,1 -"C1200W",boiler,12,dhw.cylmiddletemp,cylinder middle temperature (TS3),uint16 (>=0<=3199),C,false,sensor.boiler_dhw_cylinder_middle_temperature_(TS3),sensor.boiler_dhw_cylmiddletemp,5,9,1/10,64,1 -"C1200W",boiler,12,dhw.starts,starts,uint24 (>=0<=16777214), ,false,sensor.boiler_dhw_starts,sensor.boiler_dhw_starts,5,9,1,65,2 -"C1200W",boiler,12,dhw.workm,active time,time (>=0<=16777214),minutes,false,sensor.boiler_dhw_active_time,sensor.boiler_dhw_workm,5,9,1,67,2 +"C1200W",boiler,12,dhw.chargepump,charge pump,boolean, ,false,binary_sensor.boiler_dhw_charge_pump,binary_sensor.boiler_dhw_chargepump,5,9,1,63,1 +"C1200W",boiler,12,dhw.mixertemp,mixer temperature,uint16 (>=0<=3199),C,false,sensor.boiler_dhw_mixer_temperature,sensor.boiler_dhw_mixertemp,5,9,1/10,64,1 +"C1200W",boiler,12,dhw.cylmiddletemp,cylinder middle temperature (TS3),uint16 (>=0<=3199),C,false,sensor.boiler_dhw_cylinder_middle_temperature_(TS3),sensor.boiler_dhw_cylmiddletemp,5,9,1/10,65,1 +"C1200W",boiler,12,dhw.starts,starts,uint24 (>=0<=16777214), ,false,sensor.boiler_dhw_starts,sensor.boiler_dhw_starts,5,9,1,66,2 +"C1200W",boiler,12,dhw.workm,active time,time (>=0<=16777214),minutes,false,sensor.boiler_dhw_active_time,sensor.boiler_dhw_workm,5,9,1,68,2 "C1200W",boiler,12,nompower,nominal Power,uint8 (>=0<=254),kW,true,number.boiler_nominal_Power,number.boiler_nompower,5,0,1,270,1 "C1200W",boiler,12,nrgtotal,total energy,uint24 (>=0<=167772),kWh,false,sensor.boiler_total_energy,sensor.boiler_nrgtotal,5,0,1/100,83,2 "C1200W",boiler,12,nrgheat,energy heating,uint24 (>=0<=10000000),kWh,true,number.boiler_energy_heating,number.boiler_nrgheat,5,0,1/100,85,2 @@ -388,9 +390,9 @@ device name,device type,product id,shortname,fullname,type [options...] \| (min/ "BK13/BK15, Smartline, GB1*2",boiler,64,meterheat,meter heating,uint24 (>=0<=1677721),kWh,false,sensor.boiler_meter_heating,sensor.boiler_meterheat,5,0,1/10,95,2 "BK13/BK15, Smartline, GB1*2",boiler,64,dhw.meter,meter,uint24 (>=0<=1677721),kWh,false,sensor.boiler_dhw_meter,sensor.boiler_dhw_meter,5,9,1/10,2,2 "BK13/BK15, Smartline, GB1*2",boiler,64,gasmeterheat,gas meter heating,uint24 (>=0<=1677721),kWh,false,sensor.boiler_gas_meter_heating,sensor.boiler_gasmeterheat,5,0,1/10,266,2 -"BK13/BK15, Smartline, GB1*2",boiler,64,dhw.gasmeter,gas meter,uint24 (>=0<=1677721),kWh,false,sensor.boiler_dhw_gas_meter,sensor.boiler_dhw_gasmeter,5,9,1/10,69,2 +"BK13/BK15, Smartline, GB1*2",boiler,64,dhw.gasmeter,gas meter,uint24 (>=0<=1677721),kWh,false,sensor.boiler_dhw_gas_meter,sensor.boiler_dhw_gasmeter,5,9,1/10,70,2 "BK13/BK15, Smartline, GB1*2",boiler,64,nrgheat2,energy heating 2,uint24 (>=0<=1677721),kWh,false,sensor.boiler_energy_heating_2,sensor.boiler_nrgheat2,5,0,1/10,268,2 -"BK13/BK15, Smartline, GB1*2",boiler,64,dhw.nrg2,energy 2,uint24 (>=0<=1677721),kWh,false,sensor.boiler_dhw_energy_2,sensor.boiler_dhw_nrg2,5,9,1/10,71,2 +"BK13/BK15, Smartline, GB1*2",boiler,64,dhw.nrg2,energy 2,uint24 (>=0<=1677721),kWh,false,sensor.boiler_dhw_energy_2,sensor.boiler_dhw_nrg2,5,9,1/10,72,2 "BK13/BK15, Smartline, GB1*2",boiler,64,dhw.tapactivated,turn on/off,boolean, ,true,switch.boiler_dhw_turn_on/off,switch.boiler_dhw_tapactivated,5,9,1,28,1 "BK13/BK15, Smartline, GB1*2",boiler,64,dhw.settemp,set temperature,uint8 (>=0<=254),C,false,sensor.boiler_dhw_set_temperature,sensor.boiler_dhw_settemp,5,9,1,29,1 "BK13/BK15, Smartline, GB1*2",boiler,64,dhw.seltemp,selected temperature,uint8 (>=0<=254),C,true,number.boiler_dhw_selected_temperature,number.boiler_dhw_seltemp,5,9,1,30,1 @@ -426,10 +428,11 @@ device name,device type,product id,shortname,fullname,type [options...] \| (min/ "BK13/BK15, Smartline, GB1*2",boiler,64,dhw.tempok,temperature ok,boolean, ,false,binary_sensor.boiler_dhw_temperature_ok,binary_sensor.boiler_dhw_tempok,5,9,1,60,1 "BK13/BK15, Smartline, GB1*2",boiler,64,dhw.active,active,boolean, ,false,binary_sensor.boiler_dhw_active,binary_sensor.boiler_dhw_active,5,9,1,61,1 "BK13/BK15, Smartline, GB1*2",boiler,64,dhw.3wayvalve,3-way valve active,boolean, ,false,binary_sensor.boiler_dhw_3-way_valve_active,binary_sensor.boiler_dhw_3wayvalve,5,9,1,62,1 -"BK13/BK15, Smartline, GB1*2",boiler,64,dhw.mixertemp,mixer temperature,uint16 (>=0<=3199),C,false,sensor.boiler_dhw_mixer_temperature,sensor.boiler_dhw_mixertemp,5,9,1/10,63,1 -"BK13/BK15, Smartline, GB1*2",boiler,64,dhw.cylmiddletemp,cylinder middle temperature (TS3),uint16 (>=0<=3199),C,false,sensor.boiler_dhw_cylinder_middle_temperature_(TS3),sensor.boiler_dhw_cylmiddletemp,5,9,1/10,64,1 -"BK13/BK15, Smartline, GB1*2",boiler,64,dhw.starts,starts,uint24 (>=0<=16777214), ,false,sensor.boiler_dhw_starts,sensor.boiler_dhw_starts,5,9,1,65,2 -"BK13/BK15, Smartline, GB1*2",boiler,64,dhw.workm,active time,time (>=0<=16777214),minutes,false,sensor.boiler_dhw_active_time,sensor.boiler_dhw_workm,5,9,1,67,2 +"BK13/BK15, Smartline, GB1*2",boiler,64,dhw.chargepump,charge pump,boolean, ,false,binary_sensor.boiler_dhw_charge_pump,binary_sensor.boiler_dhw_chargepump,5,9,1,63,1 +"BK13/BK15, Smartline, GB1*2",boiler,64,dhw.mixertemp,mixer temperature,uint16 (>=0<=3199),C,false,sensor.boiler_dhw_mixer_temperature,sensor.boiler_dhw_mixertemp,5,9,1/10,64,1 +"BK13/BK15, Smartline, GB1*2",boiler,64,dhw.cylmiddletemp,cylinder middle temperature (TS3),uint16 (>=0<=3199),C,false,sensor.boiler_dhw_cylinder_middle_temperature_(TS3),sensor.boiler_dhw_cylmiddletemp,5,9,1/10,65,1 +"BK13/BK15, Smartline, GB1*2",boiler,64,dhw.starts,starts,uint24 (>=0<=16777214), ,false,sensor.boiler_dhw_starts,sensor.boiler_dhw_starts,5,9,1,66,2 +"BK13/BK15, Smartline, GB1*2",boiler,64,dhw.workm,active time,time (>=0<=16777214),minutes,false,sensor.boiler_dhw_active_time,sensor.boiler_dhw_workm,5,9,1,68,2 "BK13/BK15, Smartline, GB1*2",boiler,64,nompower,nominal Power,uint8 (>=0<=254),kW,true,number.boiler_nominal_Power,number.boiler_nompower,5,0,1,270,1 "BK13/BK15, Smartline, GB1*2",boiler,64,nrgtotal,total energy,uint24 (>=0<=167772),kWh,false,sensor.boiler_total_energy,sensor.boiler_nrgtotal,5,0,1/100,83,2 "BK13/BK15, Smartline, GB1*2",boiler,64,nrgheat,energy heating,uint24 (>=0<=10000000),kWh,true,number.boiler_energy_heating,number.boiler_nrgheat,5,0,1/100,85,2 @@ -502,9 +505,9 @@ device name,device type,product id,shortname,fullname,type [options...] \| (min/ "Logano GB1*5, Logamatic MC10",boiler,72,meterheat,meter heating,uint24 (>=0<=1677721),kWh,false,sensor.boiler_meter_heating,sensor.boiler_meterheat,5,0,1/10,95,2 "Logano GB1*5, Logamatic MC10",boiler,72,dhw.meter,meter,uint24 (>=0<=1677721),kWh,false,sensor.boiler_dhw_meter,sensor.boiler_dhw_meter,5,9,1/10,2,2 "Logano GB1*5, Logamatic MC10",boiler,72,gasmeterheat,gas meter heating,uint24 (>=0<=1677721),kWh,false,sensor.boiler_gas_meter_heating,sensor.boiler_gasmeterheat,5,0,1/10,266,2 -"Logano GB1*5, Logamatic MC10",boiler,72,dhw.gasmeter,gas meter,uint24 (>=0<=1677721),kWh,false,sensor.boiler_dhw_gas_meter,sensor.boiler_dhw_gasmeter,5,9,1/10,69,2 +"Logano GB1*5, Logamatic MC10",boiler,72,dhw.gasmeter,gas meter,uint24 (>=0<=1677721),kWh,false,sensor.boiler_dhw_gas_meter,sensor.boiler_dhw_gasmeter,5,9,1/10,70,2 "Logano GB1*5, Logamatic MC10",boiler,72,nrgheat2,energy heating 2,uint24 (>=0<=1677721),kWh,false,sensor.boiler_energy_heating_2,sensor.boiler_nrgheat2,5,0,1/10,268,2 -"Logano GB1*5, Logamatic MC10",boiler,72,dhw.nrg2,energy 2,uint24 (>=0<=1677721),kWh,false,sensor.boiler_dhw_energy_2,sensor.boiler_dhw_nrg2,5,9,1/10,71,2 +"Logano GB1*5, Logamatic MC10",boiler,72,dhw.nrg2,energy 2,uint24 (>=0<=1677721),kWh,false,sensor.boiler_dhw_energy_2,sensor.boiler_dhw_nrg2,5,9,1/10,72,2 "Logano GB1*5, Logamatic MC10",boiler,72,dhw.tapactivated,turn on/off,boolean, ,true,switch.boiler_dhw_turn_on/off,switch.boiler_dhw_tapactivated,5,9,1,28,1 "Logano GB1*5, Logamatic MC10",boiler,72,dhw.settemp,set temperature,uint8 (>=0<=254),C,false,sensor.boiler_dhw_set_temperature,sensor.boiler_dhw_settemp,5,9,1,29,1 "Logano GB1*5, Logamatic MC10",boiler,72,dhw.seltemp,selected temperature,uint8 (>=0<=254),C,true,number.boiler_dhw_selected_temperature,number.boiler_dhw_seltemp,5,9,1,30,1 @@ -540,10 +543,11 @@ device name,device type,product id,shortname,fullname,type [options...] \| (min/ "Logano GB1*5, Logamatic MC10",boiler,72,dhw.tempok,temperature ok,boolean, ,false,binary_sensor.boiler_dhw_temperature_ok,binary_sensor.boiler_dhw_tempok,5,9,1,60,1 "Logano GB1*5, Logamatic MC10",boiler,72,dhw.active,active,boolean, ,false,binary_sensor.boiler_dhw_active,binary_sensor.boiler_dhw_active,5,9,1,61,1 "Logano GB1*5, Logamatic MC10",boiler,72,dhw.3wayvalve,3-way valve active,boolean, ,false,binary_sensor.boiler_dhw_3-way_valve_active,binary_sensor.boiler_dhw_3wayvalve,5,9,1,62,1 -"Logano GB1*5, Logamatic MC10",boiler,72,dhw.mixertemp,mixer temperature,uint16 (>=0<=3199),C,false,sensor.boiler_dhw_mixer_temperature,sensor.boiler_dhw_mixertemp,5,9,1/10,63,1 -"Logano GB1*5, Logamatic MC10",boiler,72,dhw.cylmiddletemp,cylinder middle temperature (TS3),uint16 (>=0<=3199),C,false,sensor.boiler_dhw_cylinder_middle_temperature_(TS3),sensor.boiler_dhw_cylmiddletemp,5,9,1/10,64,1 -"Logano GB1*5, Logamatic MC10",boiler,72,dhw.starts,starts,uint24 (>=0<=16777214), ,false,sensor.boiler_dhw_starts,sensor.boiler_dhw_starts,5,9,1,65,2 -"Logano GB1*5, Logamatic MC10",boiler,72,dhw.workm,active time,time (>=0<=16777214),minutes,false,sensor.boiler_dhw_active_time,sensor.boiler_dhw_workm,5,9,1,67,2 +"Logano GB1*5, Logamatic MC10",boiler,72,dhw.chargepump,charge pump,boolean, ,false,binary_sensor.boiler_dhw_charge_pump,binary_sensor.boiler_dhw_chargepump,5,9,1,63,1 +"Logano GB1*5, Logamatic MC10",boiler,72,dhw.mixertemp,mixer temperature,uint16 (>=0<=3199),C,false,sensor.boiler_dhw_mixer_temperature,sensor.boiler_dhw_mixertemp,5,9,1/10,64,1 +"Logano GB1*5, Logamatic MC10",boiler,72,dhw.cylmiddletemp,cylinder middle temperature (TS3),uint16 (>=0<=3199),C,false,sensor.boiler_dhw_cylinder_middle_temperature_(TS3),sensor.boiler_dhw_cylmiddletemp,5,9,1/10,65,1 +"Logano GB1*5, Logamatic MC10",boiler,72,dhw.starts,starts,uint24 (>=0<=16777214), ,false,sensor.boiler_dhw_starts,sensor.boiler_dhw_starts,5,9,1,66,2 +"Logano GB1*5, Logamatic MC10",boiler,72,dhw.workm,active time,time (>=0<=16777214),minutes,false,sensor.boiler_dhw_active_time,sensor.boiler_dhw_workm,5,9,1,68,2 "Logano GB1*5, Logamatic MC10",boiler,72,nompower,nominal Power,uint8 (>=0<=254),kW,true,number.boiler_nominal_Power,number.boiler_nompower,5,0,1,270,1 "Logano GB1*5, Logamatic MC10",boiler,72,nrgtotal,total energy,uint24 (>=0<=167772),kWh,false,sensor.boiler_total_energy,sensor.boiler_nrgtotal,5,0,1/100,83,2 "Logano GB1*5, Logamatic MC10",boiler,72,nrgheat,energy heating,uint24 (>=0<=10000000),kWh,true,number.boiler_energy_heating,number.boiler_nrgheat,5,0,1/100,85,2 @@ -616,9 +620,9 @@ device name,device type,product id,shortname,fullname,type [options...] \| (min/ "Cascade CM10",boiler,81,meterheat,meter heating,uint24 (>=0<=1677721),kWh,false,sensor.boiler_meter_heating,sensor.boiler_meterheat,5,0,1/10,95,2 "Cascade CM10",boiler,81,dhw.meter,meter,uint24 (>=0<=1677721),kWh,false,sensor.boiler_dhw_meter,sensor.boiler_dhw_meter,5,9,1/10,2,2 "Cascade CM10",boiler,81,gasmeterheat,gas meter heating,uint24 (>=0<=1677721),kWh,false,sensor.boiler_gas_meter_heating,sensor.boiler_gasmeterheat,5,0,1/10,266,2 -"Cascade CM10",boiler,81,dhw.gasmeter,gas meter,uint24 (>=0<=1677721),kWh,false,sensor.boiler_dhw_gas_meter,sensor.boiler_dhw_gasmeter,5,9,1/10,69,2 +"Cascade CM10",boiler,81,dhw.gasmeter,gas meter,uint24 (>=0<=1677721),kWh,false,sensor.boiler_dhw_gas_meter,sensor.boiler_dhw_gasmeter,5,9,1/10,70,2 "Cascade CM10",boiler,81,nrgheat2,energy heating 2,uint24 (>=0<=1677721),kWh,false,sensor.boiler_energy_heating_2,sensor.boiler_nrgheat2,5,0,1/10,268,2 -"Cascade CM10",boiler,81,dhw.nrg2,energy 2,uint24 (>=0<=1677721),kWh,false,sensor.boiler_dhw_energy_2,sensor.boiler_dhw_nrg2,5,9,1/10,71,2 +"Cascade CM10",boiler,81,dhw.nrg2,energy 2,uint24 (>=0<=1677721),kWh,false,sensor.boiler_dhw_energy_2,sensor.boiler_dhw_nrg2,5,9,1/10,72,2 "Cascade CM10",boiler,81,dhw.tapactivated,turn on/off,boolean, ,true,switch.boiler_dhw_turn_on/off,switch.boiler_dhw_tapactivated,5,9,1,28,1 "Cascade CM10",boiler,81,dhw.settemp,set temperature,uint8 (>=0<=254),C,false,sensor.boiler_dhw_set_temperature,sensor.boiler_dhw_settemp,5,9,1,29,1 "Cascade CM10",boiler,81,dhw.seltemp,selected temperature,uint8 (>=0<=254),C,true,number.boiler_dhw_selected_temperature,number.boiler_dhw_seltemp,5,9,1,30,1 @@ -654,10 +658,11 @@ device name,device type,product id,shortname,fullname,type [options...] \| (min/ "Cascade CM10",boiler,81,dhw.tempok,temperature ok,boolean, ,false,binary_sensor.boiler_dhw_temperature_ok,binary_sensor.boiler_dhw_tempok,5,9,1,60,1 "Cascade CM10",boiler,81,dhw.active,active,boolean, ,false,binary_sensor.boiler_dhw_active,binary_sensor.boiler_dhw_active,5,9,1,61,1 "Cascade CM10",boiler,81,dhw.3wayvalve,3-way valve active,boolean, ,false,binary_sensor.boiler_dhw_3-way_valve_active,binary_sensor.boiler_dhw_3wayvalve,5,9,1,62,1 -"Cascade CM10",boiler,81,dhw.mixertemp,mixer temperature,uint16 (>=0<=3199),C,false,sensor.boiler_dhw_mixer_temperature,sensor.boiler_dhw_mixertemp,5,9,1/10,63,1 -"Cascade CM10",boiler,81,dhw.cylmiddletemp,cylinder middle temperature (TS3),uint16 (>=0<=3199),C,false,sensor.boiler_dhw_cylinder_middle_temperature_(TS3),sensor.boiler_dhw_cylmiddletemp,5,9,1/10,64,1 -"Cascade CM10",boiler,81,dhw.starts,starts,uint24 (>=0<=16777214), ,false,sensor.boiler_dhw_starts,sensor.boiler_dhw_starts,5,9,1,65,2 -"Cascade CM10",boiler,81,dhw.workm,active time,time (>=0<=16777214),minutes,false,sensor.boiler_dhw_active_time,sensor.boiler_dhw_workm,5,9,1,67,2 +"Cascade CM10",boiler,81,dhw.chargepump,charge pump,boolean, ,false,binary_sensor.boiler_dhw_charge_pump,binary_sensor.boiler_dhw_chargepump,5,9,1,63,1 +"Cascade CM10",boiler,81,dhw.mixertemp,mixer temperature,uint16 (>=0<=3199),C,false,sensor.boiler_dhw_mixer_temperature,sensor.boiler_dhw_mixertemp,5,9,1/10,64,1 +"Cascade CM10",boiler,81,dhw.cylmiddletemp,cylinder middle temperature (TS3),uint16 (>=0<=3199),C,false,sensor.boiler_dhw_cylinder_middle_temperature_(TS3),sensor.boiler_dhw_cylmiddletemp,5,9,1/10,65,1 +"Cascade CM10",boiler,81,dhw.starts,starts,uint24 (>=0<=16777214), ,false,sensor.boiler_dhw_starts,sensor.boiler_dhw_starts,5,9,1,66,2 +"Cascade CM10",boiler,81,dhw.workm,active time,time (>=0<=16777214),minutes,false,sensor.boiler_dhw_active_time,sensor.boiler_dhw_workm,5,9,1,68,2 "Cascade CM10",boiler,81,nompower,nominal Power,uint8 (>=0<=254),kW,true,number.boiler_nominal_Power,number.boiler_nompower,5,0,1,270,1 "Cascade CM10",boiler,81,nrgtotal,total energy,uint24 (>=0<=167772),kWh,false,sensor.boiler_total_energy,sensor.boiler_nrgtotal,5,0,1/100,83,2 "Cascade CM10",boiler,81,nrgheat,energy heating,uint24 (>=0<=10000000),kWh,true,number.boiler_energy_heating,number.boiler_nrgheat,5,0,1/100,85,2 @@ -730,9 +735,9 @@ device name,device type,product id,shortname,fullname,type [options...] \| (min/ "Logamax Plus GB022",boiler,84,meterheat,meter heating,uint24 (>=0<=1677721),kWh,false,sensor.boiler_meter_heating,sensor.boiler_meterheat,5,0,1/10,95,2 "Logamax Plus GB022",boiler,84,dhw.meter,meter,uint24 (>=0<=1677721),kWh,false,sensor.boiler_dhw_meter,sensor.boiler_dhw_meter,5,9,1/10,2,2 "Logamax Plus GB022",boiler,84,gasmeterheat,gas meter heating,uint24 (>=0<=1677721),kWh,false,sensor.boiler_gas_meter_heating,sensor.boiler_gasmeterheat,5,0,1/10,266,2 -"Logamax Plus GB022",boiler,84,dhw.gasmeter,gas meter,uint24 (>=0<=1677721),kWh,false,sensor.boiler_dhw_gas_meter,sensor.boiler_dhw_gasmeter,5,9,1/10,69,2 +"Logamax Plus GB022",boiler,84,dhw.gasmeter,gas meter,uint24 (>=0<=1677721),kWh,false,sensor.boiler_dhw_gas_meter,sensor.boiler_dhw_gasmeter,5,9,1/10,70,2 "Logamax Plus GB022",boiler,84,nrgheat2,energy heating 2,uint24 (>=0<=1677721),kWh,false,sensor.boiler_energy_heating_2,sensor.boiler_nrgheat2,5,0,1/10,268,2 -"Logamax Plus GB022",boiler,84,dhw.nrg2,energy 2,uint24 (>=0<=1677721),kWh,false,sensor.boiler_dhw_energy_2,sensor.boiler_dhw_nrg2,5,9,1/10,71,2 +"Logamax Plus GB022",boiler,84,dhw.nrg2,energy 2,uint24 (>=0<=1677721),kWh,false,sensor.boiler_dhw_energy_2,sensor.boiler_dhw_nrg2,5,9,1/10,72,2 "Logamax Plus GB022",boiler,84,dhw.tapactivated,turn on/off,boolean, ,true,switch.boiler_dhw_turn_on/off,switch.boiler_dhw_tapactivated,5,9,1,28,1 "Logamax Plus GB022",boiler,84,dhw.settemp,set temperature,uint8 (>=0<=254),C,false,sensor.boiler_dhw_set_temperature,sensor.boiler_dhw_settemp,5,9,1,29,1 "Logamax Plus GB022",boiler,84,dhw.seltemp,selected temperature,uint8 (>=0<=254),C,true,number.boiler_dhw_selected_temperature,number.boiler_dhw_seltemp,5,9,1,30,1 @@ -768,10 +773,11 @@ device name,device type,product id,shortname,fullname,type [options...] \| (min/ "Logamax Plus GB022",boiler,84,dhw.tempok,temperature ok,boolean, ,false,binary_sensor.boiler_dhw_temperature_ok,binary_sensor.boiler_dhw_tempok,5,9,1,60,1 "Logamax Plus GB022",boiler,84,dhw.active,active,boolean, ,false,binary_sensor.boiler_dhw_active,binary_sensor.boiler_dhw_active,5,9,1,61,1 "Logamax Plus GB022",boiler,84,dhw.3wayvalve,3-way valve active,boolean, ,false,binary_sensor.boiler_dhw_3-way_valve_active,binary_sensor.boiler_dhw_3wayvalve,5,9,1,62,1 -"Logamax Plus GB022",boiler,84,dhw.mixertemp,mixer temperature,uint16 (>=0<=3199),C,false,sensor.boiler_dhw_mixer_temperature,sensor.boiler_dhw_mixertemp,5,9,1/10,63,1 -"Logamax Plus GB022",boiler,84,dhw.cylmiddletemp,cylinder middle temperature (TS3),uint16 (>=0<=3199),C,false,sensor.boiler_dhw_cylinder_middle_temperature_(TS3),sensor.boiler_dhw_cylmiddletemp,5,9,1/10,64,1 -"Logamax Plus GB022",boiler,84,dhw.starts,starts,uint24 (>=0<=16777214), ,false,sensor.boiler_dhw_starts,sensor.boiler_dhw_starts,5,9,1,65,2 -"Logamax Plus GB022",boiler,84,dhw.workm,active time,time (>=0<=16777214),minutes,false,sensor.boiler_dhw_active_time,sensor.boiler_dhw_workm,5,9,1,67,2 +"Logamax Plus GB022",boiler,84,dhw.chargepump,charge pump,boolean, ,false,binary_sensor.boiler_dhw_charge_pump,binary_sensor.boiler_dhw_chargepump,5,9,1,63,1 +"Logamax Plus GB022",boiler,84,dhw.mixertemp,mixer temperature,uint16 (>=0<=3199),C,false,sensor.boiler_dhw_mixer_temperature,sensor.boiler_dhw_mixertemp,5,9,1/10,64,1 +"Logamax Plus GB022",boiler,84,dhw.cylmiddletemp,cylinder middle temperature (TS3),uint16 (>=0<=3199),C,false,sensor.boiler_dhw_cylinder_middle_temperature_(TS3),sensor.boiler_dhw_cylmiddletemp,5,9,1/10,65,1 +"Logamax Plus GB022",boiler,84,dhw.starts,starts,uint24 (>=0<=16777214), ,false,sensor.boiler_dhw_starts,sensor.boiler_dhw_starts,5,9,1,66,2 +"Logamax Plus GB022",boiler,84,dhw.workm,active time,time (>=0<=16777214),minutes,false,sensor.boiler_dhw_active_time,sensor.boiler_dhw_workm,5,9,1,68,2 "Logamax Plus GB022",boiler,84,nompower,nominal Power,uint8 (>=0<=254),kW,true,number.boiler_nominal_Power,number.boiler_nompower,5,0,1,270,1 "Logamax Plus GB022",boiler,84,nrgtotal,total energy,uint24 (>=0<=167772),kWh,false,sensor.boiler_total_energy,sensor.boiler_nrgtotal,5,0,1/100,83,2 "Logamax Plus GB022",boiler,84,nrgheat,energy heating,uint24 (>=0<=10000000),kWh,true,number.boiler_energy_heating,number.boiler_nrgheat,5,0,1/100,85,2 @@ -844,9 +850,9 @@ device name,device type,product id,shortname,fullname,type [options...] \| (min/ "Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3",boiler,95,meterheat,meter heating,uint24 (>=0<=1677721),kWh,false,sensor.boiler_meter_heating,sensor.boiler_meterheat,5,0,1/10,95,2 "Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3",boiler,95,dhw.meter,meter,uint24 (>=0<=1677721),kWh,false,sensor.boiler_dhw_meter,sensor.boiler_dhw_meter,5,9,1/10,2,2 "Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3",boiler,95,gasmeterheat,gas meter heating,uint24 (>=0<=1677721),kWh,false,sensor.boiler_gas_meter_heating,sensor.boiler_gasmeterheat,5,0,1/10,266,2 -"Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3",boiler,95,dhw.gasmeter,gas meter,uint24 (>=0<=1677721),kWh,false,sensor.boiler_dhw_gas_meter,sensor.boiler_dhw_gasmeter,5,9,1/10,69,2 +"Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3",boiler,95,dhw.gasmeter,gas meter,uint24 (>=0<=1677721),kWh,false,sensor.boiler_dhw_gas_meter,sensor.boiler_dhw_gasmeter,5,9,1/10,70,2 "Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3",boiler,95,nrgheat2,energy heating 2,uint24 (>=0<=1677721),kWh,false,sensor.boiler_energy_heating_2,sensor.boiler_nrgheat2,5,0,1/10,268,2 -"Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3",boiler,95,dhw.nrg2,energy 2,uint24 (>=0<=1677721),kWh,false,sensor.boiler_dhw_energy_2,sensor.boiler_dhw_nrg2,5,9,1/10,71,2 +"Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3",boiler,95,dhw.nrg2,energy 2,uint24 (>=0<=1677721),kWh,false,sensor.boiler_dhw_energy_2,sensor.boiler_dhw_nrg2,5,9,1/10,72,2 "Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3",boiler,95,dhw.tapactivated,turn on/off,boolean, ,true,switch.boiler_dhw_turn_on/off,switch.boiler_dhw_tapactivated,5,9,1,28,1 "Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3",boiler,95,dhw.settemp,set temperature,uint8 (>=0<=254),C,false,sensor.boiler_dhw_set_temperature,sensor.boiler_dhw_settemp,5,9,1,29,1 "Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3",boiler,95,dhw.seltemp,selected temperature,uint8 (>=0<=254),C,true,number.boiler_dhw_selected_temperature,number.boiler_dhw_seltemp,5,9,1,30,1 @@ -882,10 +888,11 @@ device name,device type,product id,shortname,fullname,type [options...] \| (min/ "Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3",boiler,95,dhw.tempok,temperature ok,boolean, ,false,binary_sensor.boiler_dhw_temperature_ok,binary_sensor.boiler_dhw_tempok,5,9,1,60,1 "Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3",boiler,95,dhw.active,active,boolean, ,false,binary_sensor.boiler_dhw_active,binary_sensor.boiler_dhw_active,5,9,1,61,1 "Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3",boiler,95,dhw.3wayvalve,3-way valve active,boolean, ,false,binary_sensor.boiler_dhw_3-way_valve_active,binary_sensor.boiler_dhw_3wayvalve,5,9,1,62,1 -"Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3",boiler,95,dhw.mixertemp,mixer temperature,uint16 (>=0<=3199),C,false,sensor.boiler_dhw_mixer_temperature,sensor.boiler_dhw_mixertemp,5,9,1/10,63,1 -"Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3",boiler,95,dhw.cylmiddletemp,cylinder middle temperature (TS3),uint16 (>=0<=3199),C,false,sensor.boiler_dhw_cylinder_middle_temperature_(TS3),sensor.boiler_dhw_cylmiddletemp,5,9,1/10,64,1 -"Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3",boiler,95,dhw.starts,starts,uint24 (>=0<=16777214), ,false,sensor.boiler_dhw_starts,sensor.boiler_dhw_starts,5,9,1,65,2 -"Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3",boiler,95,dhw.workm,active time,time (>=0<=16777214),minutes,false,sensor.boiler_dhw_active_time,sensor.boiler_dhw_workm,5,9,1,67,2 +"Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3",boiler,95,dhw.chargepump,charge pump,boolean, ,false,binary_sensor.boiler_dhw_charge_pump,binary_sensor.boiler_dhw_chargepump,5,9,1,63,1 +"Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3",boiler,95,dhw.mixertemp,mixer temperature,uint16 (>=0<=3199),C,false,sensor.boiler_dhw_mixer_temperature,sensor.boiler_dhw_mixertemp,5,9,1/10,64,1 +"Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3",boiler,95,dhw.cylmiddletemp,cylinder middle temperature (TS3),uint16 (>=0<=3199),C,false,sensor.boiler_dhw_cylinder_middle_temperature_(TS3),sensor.boiler_dhw_cylmiddletemp,5,9,1/10,65,1 +"Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3",boiler,95,dhw.starts,starts,uint24 (>=0<=16777214), ,false,sensor.boiler_dhw_starts,sensor.boiler_dhw_starts,5,9,1,66,2 +"Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3",boiler,95,dhw.workm,active time,time (>=0<=16777214),minutes,false,sensor.boiler_dhw_active_time,sensor.boiler_dhw_workm,5,9,1,68,2 "Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3",boiler,95,nompower,nominal Power,uint8 (>=0<=254),kW,true,number.boiler_nominal_Power,number.boiler_nompower,5,0,1,270,1 "Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3",boiler,95,nrgtotal,total energy,uint24 (>=0<=167772),kWh,false,sensor.boiler_total_energy,sensor.boiler_nrgtotal,5,0,1/100,83,2 "Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3",boiler,95,nrgheat,energy heating,uint24 (>=0<=10000000),kWh,true,number.boiler_energy_heating,number.boiler_nrgheat,5,0,1/100,85,2 @@ -958,9 +965,9 @@ device name,device type,product id,shortname,fullname,type [options...] \| (min/ "Topline, GB162",boiler,115,meterheat,meter heating,uint24 (>=0<=1677721),kWh,false,sensor.boiler_meter_heating,sensor.boiler_meterheat,5,0,1/10,95,2 "Topline, GB162",boiler,115,dhw.meter,meter,uint24 (>=0<=1677721),kWh,false,sensor.boiler_dhw_meter,sensor.boiler_dhw_meter,5,9,1/10,2,2 "Topline, GB162",boiler,115,gasmeterheat,gas meter heating,uint24 (>=0<=1677721),kWh,false,sensor.boiler_gas_meter_heating,sensor.boiler_gasmeterheat,5,0,1/10,266,2 -"Topline, GB162",boiler,115,dhw.gasmeter,gas meter,uint24 (>=0<=1677721),kWh,false,sensor.boiler_dhw_gas_meter,sensor.boiler_dhw_gasmeter,5,9,1/10,69,2 +"Topline, GB162",boiler,115,dhw.gasmeter,gas meter,uint24 (>=0<=1677721),kWh,false,sensor.boiler_dhw_gas_meter,sensor.boiler_dhw_gasmeter,5,9,1/10,70,2 "Topline, GB162",boiler,115,nrgheat2,energy heating 2,uint24 (>=0<=1677721),kWh,false,sensor.boiler_energy_heating_2,sensor.boiler_nrgheat2,5,0,1/10,268,2 -"Topline, GB162",boiler,115,dhw.nrg2,energy 2,uint24 (>=0<=1677721),kWh,false,sensor.boiler_dhw_energy_2,sensor.boiler_dhw_nrg2,5,9,1/10,71,2 +"Topline, GB162",boiler,115,dhw.nrg2,energy 2,uint24 (>=0<=1677721),kWh,false,sensor.boiler_dhw_energy_2,sensor.boiler_dhw_nrg2,5,9,1/10,72,2 "Topline, GB162",boiler,115,dhw.tapactivated,turn on/off,boolean, ,true,switch.boiler_dhw_turn_on/off,switch.boiler_dhw_tapactivated,5,9,1,28,1 "Topline, GB162",boiler,115,dhw.settemp,set temperature,uint8 (>=0<=254),C,false,sensor.boiler_dhw_set_temperature,sensor.boiler_dhw_settemp,5,9,1,29,1 "Topline, GB162",boiler,115,dhw.seltemp,selected temperature,uint8 (>=0<=254),C,true,number.boiler_dhw_selected_temperature,number.boiler_dhw_seltemp,5,9,1,30,1 @@ -996,10 +1003,11 @@ device name,device type,product id,shortname,fullname,type [options...] \| (min/ "Topline, GB162",boiler,115,dhw.tempok,temperature ok,boolean, ,false,binary_sensor.boiler_dhw_temperature_ok,binary_sensor.boiler_dhw_tempok,5,9,1,60,1 "Topline, GB162",boiler,115,dhw.active,active,boolean, ,false,binary_sensor.boiler_dhw_active,binary_sensor.boiler_dhw_active,5,9,1,61,1 "Topline, GB162",boiler,115,dhw.3wayvalve,3-way valve active,boolean, ,false,binary_sensor.boiler_dhw_3-way_valve_active,binary_sensor.boiler_dhw_3wayvalve,5,9,1,62,1 -"Topline, GB162",boiler,115,dhw.mixertemp,mixer temperature,uint16 (>=0<=3199),C,false,sensor.boiler_dhw_mixer_temperature,sensor.boiler_dhw_mixertemp,5,9,1/10,63,1 -"Topline, GB162",boiler,115,dhw.cylmiddletemp,cylinder middle temperature (TS3),uint16 (>=0<=3199),C,false,sensor.boiler_dhw_cylinder_middle_temperature_(TS3),sensor.boiler_dhw_cylmiddletemp,5,9,1/10,64,1 -"Topline, GB162",boiler,115,dhw.starts,starts,uint24 (>=0<=16777214), ,false,sensor.boiler_dhw_starts,sensor.boiler_dhw_starts,5,9,1,65,2 -"Topline, GB162",boiler,115,dhw.workm,active time,time (>=0<=16777214),minutes,false,sensor.boiler_dhw_active_time,sensor.boiler_dhw_workm,5,9,1,67,2 +"Topline, GB162",boiler,115,dhw.chargepump,charge pump,boolean, ,false,binary_sensor.boiler_dhw_charge_pump,binary_sensor.boiler_dhw_chargepump,5,9,1,63,1 +"Topline, GB162",boiler,115,dhw.mixertemp,mixer temperature,uint16 (>=0<=3199),C,false,sensor.boiler_dhw_mixer_temperature,sensor.boiler_dhw_mixertemp,5,9,1/10,64,1 +"Topline, GB162",boiler,115,dhw.cylmiddletemp,cylinder middle temperature (TS3),uint16 (>=0<=3199),C,false,sensor.boiler_dhw_cylinder_middle_temperature_(TS3),sensor.boiler_dhw_cylmiddletemp,5,9,1/10,65,1 +"Topline, GB162",boiler,115,dhw.starts,starts,uint24 (>=0<=16777214), ,false,sensor.boiler_dhw_starts,sensor.boiler_dhw_starts,5,9,1,66,2 +"Topline, GB162",boiler,115,dhw.workm,active time,time (>=0<=16777214),minutes,false,sensor.boiler_dhw_active_time,sensor.boiler_dhw_workm,5,9,1,68,2 "Topline, GB162",boiler,115,nompower,nominal Power,uint8 (>=0<=254),kW,true,number.boiler_nominal_Power,number.boiler_nompower,5,0,1,270,1 "Topline, GB162",boiler,115,nrgtotal,total energy,uint24 (>=0<=167772),kWh,false,sensor.boiler_total_energy,sensor.boiler_nrgtotal,5,0,1/100,83,2 "Topline, GB162",boiler,115,nrgheat,energy heating,uint24 (>=0<=10000000),kWh,true,number.boiler_energy_heating,number.boiler_nrgheat,5,0,1/100,85,2 @@ -1072,9 +1080,9 @@ device name,device type,product id,shortname,fullname,type [options...] \| (min/ "Cascade MCM10",boiler,121,meterheat,meter heating,uint24 (>=0<=1677721),kWh,false,sensor.boiler_meter_heating,sensor.boiler_meterheat,5,0,1/10,95,2 "Cascade MCM10",boiler,121,dhw.meter,meter,uint24 (>=0<=1677721),kWh,false,sensor.boiler_dhw_meter,sensor.boiler_dhw_meter,5,9,1/10,2,2 "Cascade MCM10",boiler,121,gasmeterheat,gas meter heating,uint24 (>=0<=1677721),kWh,false,sensor.boiler_gas_meter_heating,sensor.boiler_gasmeterheat,5,0,1/10,266,2 -"Cascade MCM10",boiler,121,dhw.gasmeter,gas meter,uint24 (>=0<=1677721),kWh,false,sensor.boiler_dhw_gas_meter,sensor.boiler_dhw_gasmeter,5,9,1/10,69,2 +"Cascade MCM10",boiler,121,dhw.gasmeter,gas meter,uint24 (>=0<=1677721),kWh,false,sensor.boiler_dhw_gas_meter,sensor.boiler_dhw_gasmeter,5,9,1/10,70,2 "Cascade MCM10",boiler,121,nrgheat2,energy heating 2,uint24 (>=0<=1677721),kWh,false,sensor.boiler_energy_heating_2,sensor.boiler_nrgheat2,5,0,1/10,268,2 -"Cascade MCM10",boiler,121,dhw.nrg2,energy 2,uint24 (>=0<=1677721),kWh,false,sensor.boiler_dhw_energy_2,sensor.boiler_dhw_nrg2,5,9,1/10,71,2 +"Cascade MCM10",boiler,121,dhw.nrg2,energy 2,uint24 (>=0<=1677721),kWh,false,sensor.boiler_dhw_energy_2,sensor.boiler_dhw_nrg2,5,9,1/10,72,2 "Cascade MCM10",boiler,121,dhw.tapactivated,turn on/off,boolean, ,true,switch.boiler_dhw_turn_on/off,switch.boiler_dhw_tapactivated,5,9,1,28,1 "Cascade MCM10",boiler,121,dhw.settemp,set temperature,uint8 (>=0<=254),C,false,sensor.boiler_dhw_set_temperature,sensor.boiler_dhw_settemp,5,9,1,29,1 "Cascade MCM10",boiler,121,dhw.seltemp,selected temperature,uint8 (>=0<=254),C,true,number.boiler_dhw_selected_temperature,number.boiler_dhw_seltemp,5,9,1,30,1 @@ -1110,10 +1118,11 @@ device name,device type,product id,shortname,fullname,type [options...] \| (min/ "Cascade MCM10",boiler,121,dhw.tempok,temperature ok,boolean, ,false,binary_sensor.boiler_dhw_temperature_ok,binary_sensor.boiler_dhw_tempok,5,9,1,60,1 "Cascade MCM10",boiler,121,dhw.active,active,boolean, ,false,binary_sensor.boiler_dhw_active,binary_sensor.boiler_dhw_active,5,9,1,61,1 "Cascade MCM10",boiler,121,dhw.3wayvalve,3-way valve active,boolean, ,false,binary_sensor.boiler_dhw_3-way_valve_active,binary_sensor.boiler_dhw_3wayvalve,5,9,1,62,1 -"Cascade MCM10",boiler,121,dhw.mixertemp,mixer temperature,uint16 (>=0<=3199),C,false,sensor.boiler_dhw_mixer_temperature,sensor.boiler_dhw_mixertemp,5,9,1/10,63,1 -"Cascade MCM10",boiler,121,dhw.cylmiddletemp,cylinder middle temperature (TS3),uint16 (>=0<=3199),C,false,sensor.boiler_dhw_cylinder_middle_temperature_(TS3),sensor.boiler_dhw_cylmiddletemp,5,9,1/10,64,1 -"Cascade MCM10",boiler,121,dhw.starts,starts,uint24 (>=0<=16777214), ,false,sensor.boiler_dhw_starts,sensor.boiler_dhw_starts,5,9,1,65,2 -"Cascade MCM10",boiler,121,dhw.workm,active time,time (>=0<=16777214),minutes,false,sensor.boiler_dhw_active_time,sensor.boiler_dhw_workm,5,9,1,67,2 +"Cascade MCM10",boiler,121,dhw.chargepump,charge pump,boolean, ,false,binary_sensor.boiler_dhw_charge_pump,binary_sensor.boiler_dhw_chargepump,5,9,1,63,1 +"Cascade MCM10",boiler,121,dhw.mixertemp,mixer temperature,uint16 (>=0<=3199),C,false,sensor.boiler_dhw_mixer_temperature,sensor.boiler_dhw_mixertemp,5,9,1/10,64,1 +"Cascade MCM10",boiler,121,dhw.cylmiddletemp,cylinder middle temperature (TS3),uint16 (>=0<=3199),C,false,sensor.boiler_dhw_cylinder_middle_temperature_(TS3),sensor.boiler_dhw_cylmiddletemp,5,9,1/10,65,1 +"Cascade MCM10",boiler,121,dhw.starts,starts,uint24 (>=0<=16777214), ,false,sensor.boiler_dhw_starts,sensor.boiler_dhw_starts,5,9,1,66,2 +"Cascade MCM10",boiler,121,dhw.workm,active time,time (>=0<=16777214),minutes,false,sensor.boiler_dhw_active_time,sensor.boiler_dhw_workm,5,9,1,68,2 "Cascade MCM10",boiler,121,nompower,nominal Power,uint8 (>=0<=254),kW,true,number.boiler_nominal_Power,number.boiler_nompower,5,0,1,270,1 "Cascade MCM10",boiler,121,nrgtotal,total energy,uint24 (>=0<=167772),kWh,false,sensor.boiler_total_energy,sensor.boiler_nrgtotal,5,0,1/100,83,2 "Cascade MCM10",boiler,121,nrgheat,energy heating,uint24 (>=0<=10000000),kWh,true,number.boiler_energy_heating,number.boiler_nrgheat,5,0,1/100,85,2 @@ -1186,9 +1195,9 @@ device name,device type,product id,shortname,fullname,type [options...] \| (min/ "Proline",boiler,122,meterheat,meter heating,uint24 (>=0<=1677721),kWh,false,sensor.boiler_meter_heating,sensor.boiler_meterheat,5,0,1/10,95,2 "Proline",boiler,122,dhw.meter,meter,uint24 (>=0<=1677721),kWh,false,sensor.boiler_dhw_meter,sensor.boiler_dhw_meter,5,9,1/10,2,2 "Proline",boiler,122,gasmeterheat,gas meter heating,uint24 (>=0<=1677721),kWh,false,sensor.boiler_gas_meter_heating,sensor.boiler_gasmeterheat,5,0,1/10,266,2 -"Proline",boiler,122,dhw.gasmeter,gas meter,uint24 (>=0<=1677721),kWh,false,sensor.boiler_dhw_gas_meter,sensor.boiler_dhw_gasmeter,5,9,1/10,69,2 +"Proline",boiler,122,dhw.gasmeter,gas meter,uint24 (>=0<=1677721),kWh,false,sensor.boiler_dhw_gas_meter,sensor.boiler_dhw_gasmeter,5,9,1/10,70,2 "Proline",boiler,122,nrgheat2,energy heating 2,uint24 (>=0<=1677721),kWh,false,sensor.boiler_energy_heating_2,sensor.boiler_nrgheat2,5,0,1/10,268,2 -"Proline",boiler,122,dhw.nrg2,energy 2,uint24 (>=0<=1677721),kWh,false,sensor.boiler_dhw_energy_2,sensor.boiler_dhw_nrg2,5,9,1/10,71,2 +"Proline",boiler,122,dhw.nrg2,energy 2,uint24 (>=0<=1677721),kWh,false,sensor.boiler_dhw_energy_2,sensor.boiler_dhw_nrg2,5,9,1/10,72,2 "Proline",boiler,122,dhw.tapactivated,turn on/off,boolean, ,true,switch.boiler_dhw_turn_on/off,switch.boiler_dhw_tapactivated,5,9,1,28,1 "Proline",boiler,122,dhw.settemp,set temperature,uint8 (>=0<=254),C,false,sensor.boiler_dhw_set_temperature,sensor.boiler_dhw_settemp,5,9,1,29,1 "Proline",boiler,122,dhw.seltemp,selected temperature,uint8 (>=0<=254),C,true,number.boiler_dhw_selected_temperature,number.boiler_dhw_seltemp,5,9,1,30,1 @@ -1224,10 +1233,11 @@ device name,device type,product id,shortname,fullname,type [options...] \| (min/ "Proline",boiler,122,dhw.tempok,temperature ok,boolean, ,false,binary_sensor.boiler_dhw_temperature_ok,binary_sensor.boiler_dhw_tempok,5,9,1,60,1 "Proline",boiler,122,dhw.active,active,boolean, ,false,binary_sensor.boiler_dhw_active,binary_sensor.boiler_dhw_active,5,9,1,61,1 "Proline",boiler,122,dhw.3wayvalve,3-way valve active,boolean, ,false,binary_sensor.boiler_dhw_3-way_valve_active,binary_sensor.boiler_dhw_3wayvalve,5,9,1,62,1 -"Proline",boiler,122,dhw.mixertemp,mixer temperature,uint16 (>=0<=3199),C,false,sensor.boiler_dhw_mixer_temperature,sensor.boiler_dhw_mixertemp,5,9,1/10,63,1 -"Proline",boiler,122,dhw.cylmiddletemp,cylinder middle temperature (TS3),uint16 (>=0<=3199),C,false,sensor.boiler_dhw_cylinder_middle_temperature_(TS3),sensor.boiler_dhw_cylmiddletemp,5,9,1/10,64,1 -"Proline",boiler,122,dhw.starts,starts,uint24 (>=0<=16777214), ,false,sensor.boiler_dhw_starts,sensor.boiler_dhw_starts,5,9,1,65,2 -"Proline",boiler,122,dhw.workm,active time,time (>=0<=16777214),minutes,false,sensor.boiler_dhw_active_time,sensor.boiler_dhw_workm,5,9,1,67,2 +"Proline",boiler,122,dhw.chargepump,charge pump,boolean, ,false,binary_sensor.boiler_dhw_charge_pump,binary_sensor.boiler_dhw_chargepump,5,9,1,63,1 +"Proline",boiler,122,dhw.mixertemp,mixer temperature,uint16 (>=0<=3199),C,false,sensor.boiler_dhw_mixer_temperature,sensor.boiler_dhw_mixertemp,5,9,1/10,64,1 +"Proline",boiler,122,dhw.cylmiddletemp,cylinder middle temperature (TS3),uint16 (>=0<=3199),C,false,sensor.boiler_dhw_cylinder_middle_temperature_(TS3),sensor.boiler_dhw_cylmiddletemp,5,9,1/10,65,1 +"Proline",boiler,122,dhw.starts,starts,uint24 (>=0<=16777214), ,false,sensor.boiler_dhw_starts,sensor.boiler_dhw_starts,5,9,1,66,2 +"Proline",boiler,122,dhw.workm,active time,time (>=0<=16777214),minutes,false,sensor.boiler_dhw_active_time,sensor.boiler_dhw_workm,5,9,1,68,2 "Proline",boiler,122,nompower,nominal Power,uint8 (>=0<=254),kW,true,number.boiler_nominal_Power,number.boiler_nompower,5,0,1,270,1 "Proline",boiler,122,nrgtotal,total energy,uint24 (>=0<=167772),kWh,false,sensor.boiler_total_energy,sensor.boiler_nrgtotal,5,0,1/100,83,2 "Proline",boiler,122,nrgheat,energy heating,uint24 (>=0<=10000000),kWh,true,number.boiler_energy_heating,number.boiler_nrgheat,5,0,1/100,85,2 @@ -1300,9 +1310,9 @@ device name,device type,product id,shortname,fullname,type [options...] \| (min/ "GB*72, Trendline, Cerapur, Greenstar Si",boiler,123,meterheat,meter heating,uint24 (>=0<=1677721),kWh,false,sensor.boiler_meter_heating,sensor.boiler_meterheat,5,0,1/10,95,2 "GB*72, Trendline, Cerapur, Greenstar Si",boiler,123,dhw.meter,meter,uint24 (>=0<=1677721),kWh,false,sensor.boiler_dhw_meter,sensor.boiler_dhw_meter,5,9,1/10,2,2 "GB*72, Trendline, Cerapur, Greenstar Si",boiler,123,gasmeterheat,gas meter heating,uint24 (>=0<=1677721),kWh,false,sensor.boiler_gas_meter_heating,sensor.boiler_gasmeterheat,5,0,1/10,266,2 -"GB*72, Trendline, Cerapur, Greenstar Si",boiler,123,dhw.gasmeter,gas meter,uint24 (>=0<=1677721),kWh,false,sensor.boiler_dhw_gas_meter,sensor.boiler_dhw_gasmeter,5,9,1/10,69,2 +"GB*72, Trendline, Cerapur, Greenstar Si",boiler,123,dhw.gasmeter,gas meter,uint24 (>=0<=1677721),kWh,false,sensor.boiler_dhw_gas_meter,sensor.boiler_dhw_gasmeter,5,9,1/10,70,2 "GB*72, Trendline, Cerapur, Greenstar Si",boiler,123,nrgheat2,energy heating 2,uint24 (>=0<=1677721),kWh,false,sensor.boiler_energy_heating_2,sensor.boiler_nrgheat2,5,0,1/10,268,2 -"GB*72, Trendline, Cerapur, Greenstar Si",boiler,123,dhw.nrg2,energy 2,uint24 (>=0<=1677721),kWh,false,sensor.boiler_dhw_energy_2,sensor.boiler_dhw_nrg2,5,9,1/10,71,2 +"GB*72, Trendline, Cerapur, Greenstar Si",boiler,123,dhw.nrg2,energy 2,uint24 (>=0<=1677721),kWh,false,sensor.boiler_dhw_energy_2,sensor.boiler_dhw_nrg2,5,9,1/10,72,2 "GB*72, Trendline, Cerapur, Greenstar Si",boiler,123,dhw.tapactivated,turn on/off,boolean, ,true,switch.boiler_dhw_turn_on/off,switch.boiler_dhw_tapactivated,5,9,1,28,1 "GB*72, Trendline, Cerapur, Greenstar Si",boiler,123,dhw.settemp,set temperature,uint8 (>=0<=254),C,false,sensor.boiler_dhw_set_temperature,sensor.boiler_dhw_settemp,5,9,1,29,1 "GB*72, Trendline, Cerapur, Greenstar Si",boiler,123,dhw.seltemp,selected temperature,uint8 (>=0<=254),C,true,number.boiler_dhw_selected_temperature,number.boiler_dhw_seltemp,5,9,1,30,1 @@ -1338,10 +1348,11 @@ device name,device type,product id,shortname,fullname,type [options...] \| (min/ "GB*72, Trendline, Cerapur, Greenstar Si",boiler,123,dhw.tempok,temperature ok,boolean, ,false,binary_sensor.boiler_dhw_temperature_ok,binary_sensor.boiler_dhw_tempok,5,9,1,60,1 "GB*72, Trendline, Cerapur, Greenstar Si",boiler,123,dhw.active,active,boolean, ,false,binary_sensor.boiler_dhw_active,binary_sensor.boiler_dhw_active,5,9,1,61,1 "GB*72, Trendline, Cerapur, Greenstar Si",boiler,123,dhw.3wayvalve,3-way valve active,boolean, ,false,binary_sensor.boiler_dhw_3-way_valve_active,binary_sensor.boiler_dhw_3wayvalve,5,9,1,62,1 -"GB*72, Trendline, Cerapur, Greenstar Si",boiler,123,dhw.mixertemp,mixer temperature,uint16 (>=0<=3199),C,false,sensor.boiler_dhw_mixer_temperature,sensor.boiler_dhw_mixertemp,5,9,1/10,63,1 -"GB*72, Trendline, Cerapur, Greenstar Si",boiler,123,dhw.cylmiddletemp,cylinder middle temperature (TS3),uint16 (>=0<=3199),C,false,sensor.boiler_dhw_cylinder_middle_temperature_(TS3),sensor.boiler_dhw_cylmiddletemp,5,9,1/10,64,1 -"GB*72, Trendline, Cerapur, Greenstar Si",boiler,123,dhw.starts,starts,uint24 (>=0<=16777214), ,false,sensor.boiler_dhw_starts,sensor.boiler_dhw_starts,5,9,1,65,2 -"GB*72, Trendline, Cerapur, Greenstar Si",boiler,123,dhw.workm,active time,time (>=0<=16777214),minutes,false,sensor.boiler_dhw_active_time,sensor.boiler_dhw_workm,5,9,1,67,2 +"GB*72, Trendline, Cerapur, Greenstar Si",boiler,123,dhw.chargepump,charge pump,boolean, ,false,binary_sensor.boiler_dhw_charge_pump,binary_sensor.boiler_dhw_chargepump,5,9,1,63,1 +"GB*72, Trendline, Cerapur, Greenstar Si",boiler,123,dhw.mixertemp,mixer temperature,uint16 (>=0<=3199),C,false,sensor.boiler_dhw_mixer_temperature,sensor.boiler_dhw_mixertemp,5,9,1/10,64,1 +"GB*72, Trendline, Cerapur, Greenstar Si",boiler,123,dhw.cylmiddletemp,cylinder middle temperature (TS3),uint16 (>=0<=3199),C,false,sensor.boiler_dhw_cylinder_middle_temperature_(TS3),sensor.boiler_dhw_cylmiddletemp,5,9,1/10,65,1 +"GB*72, Trendline, Cerapur, Greenstar Si",boiler,123,dhw.starts,starts,uint24 (>=0<=16777214), ,false,sensor.boiler_dhw_starts,sensor.boiler_dhw_starts,5,9,1,66,2 +"GB*72, Trendline, Cerapur, Greenstar Si",boiler,123,dhw.workm,active time,time (>=0<=16777214),minutes,false,sensor.boiler_dhw_active_time,sensor.boiler_dhw_workm,5,9,1,68,2 "GB*72, Trendline, Cerapur, Greenstar Si",boiler,123,nompower,nominal Power,uint8 (>=0<=254),kW,true,number.boiler_nominal_Power,number.boiler_nompower,5,0,1,270,1 "GB*72, Trendline, Cerapur, Greenstar Si",boiler,123,nrgtotal,total energy,uint24 (>=0<=167772),kWh,false,sensor.boiler_total_energy,sensor.boiler_nrgtotal,5,0,1/100,83,2 "GB*72, Trendline, Cerapur, Greenstar Si",boiler,123,nrgheat,energy heating,uint24 (>=0<=10000000),kWh,true,number.boiler_energy_heating,number.boiler_nrgheat,5,0,1/100,85,2 @@ -1414,9 +1425,9 @@ device name,device type,product id,shortname,fullname,type [options...] \| (min/ "GB212",boiler,131,meterheat,meter heating,uint24 (>=0<=1677721),kWh,false,sensor.boiler_meter_heating,sensor.boiler_meterheat,5,0,1/10,95,2 "GB212",boiler,131,dhw.meter,meter,uint24 (>=0<=1677721),kWh,false,sensor.boiler_dhw_meter,sensor.boiler_dhw_meter,5,9,1/10,2,2 "GB212",boiler,131,gasmeterheat,gas meter heating,uint24 (>=0<=1677721),kWh,false,sensor.boiler_gas_meter_heating,sensor.boiler_gasmeterheat,5,0,1/10,266,2 -"GB212",boiler,131,dhw.gasmeter,gas meter,uint24 (>=0<=1677721),kWh,false,sensor.boiler_dhw_gas_meter,sensor.boiler_dhw_gasmeter,5,9,1/10,69,2 +"GB212",boiler,131,dhw.gasmeter,gas meter,uint24 (>=0<=1677721),kWh,false,sensor.boiler_dhw_gas_meter,sensor.boiler_dhw_gasmeter,5,9,1/10,70,2 "GB212",boiler,131,nrgheat2,energy heating 2,uint24 (>=0<=1677721),kWh,false,sensor.boiler_energy_heating_2,sensor.boiler_nrgheat2,5,0,1/10,268,2 -"GB212",boiler,131,dhw.nrg2,energy 2,uint24 (>=0<=1677721),kWh,false,sensor.boiler_dhw_energy_2,sensor.boiler_dhw_nrg2,5,9,1/10,71,2 +"GB212",boiler,131,dhw.nrg2,energy 2,uint24 (>=0<=1677721),kWh,false,sensor.boiler_dhw_energy_2,sensor.boiler_dhw_nrg2,5,9,1/10,72,2 "GB212",boiler,131,dhw.tapactivated,turn on/off,boolean, ,true,switch.boiler_dhw_turn_on/off,switch.boiler_dhw_tapactivated,5,9,1,28,1 "GB212",boiler,131,dhw.settemp,set temperature,uint8 (>=0<=254),C,false,sensor.boiler_dhw_set_temperature,sensor.boiler_dhw_settemp,5,9,1,29,1 "GB212",boiler,131,dhw.seltemp,selected temperature,uint8 (>=0<=254),C,true,number.boiler_dhw_selected_temperature,number.boiler_dhw_seltemp,5,9,1,30,1 @@ -1452,10 +1463,11 @@ device name,device type,product id,shortname,fullname,type [options...] \| (min/ "GB212",boiler,131,dhw.tempok,temperature ok,boolean, ,false,binary_sensor.boiler_dhw_temperature_ok,binary_sensor.boiler_dhw_tempok,5,9,1,60,1 "GB212",boiler,131,dhw.active,active,boolean, ,false,binary_sensor.boiler_dhw_active,binary_sensor.boiler_dhw_active,5,9,1,61,1 "GB212",boiler,131,dhw.3wayvalve,3-way valve active,boolean, ,false,binary_sensor.boiler_dhw_3-way_valve_active,binary_sensor.boiler_dhw_3wayvalve,5,9,1,62,1 -"GB212",boiler,131,dhw.mixertemp,mixer temperature,uint16 (>=0<=3199),C,false,sensor.boiler_dhw_mixer_temperature,sensor.boiler_dhw_mixertemp,5,9,1/10,63,1 -"GB212",boiler,131,dhw.cylmiddletemp,cylinder middle temperature (TS3),uint16 (>=0<=3199),C,false,sensor.boiler_dhw_cylinder_middle_temperature_(TS3),sensor.boiler_dhw_cylmiddletemp,5,9,1/10,64,1 -"GB212",boiler,131,dhw.starts,starts,uint24 (>=0<=16777214), ,false,sensor.boiler_dhw_starts,sensor.boiler_dhw_starts,5,9,1,65,2 -"GB212",boiler,131,dhw.workm,active time,time (>=0<=16777214),minutes,false,sensor.boiler_dhw_active_time,sensor.boiler_dhw_workm,5,9,1,67,2 +"GB212",boiler,131,dhw.chargepump,charge pump,boolean, ,false,binary_sensor.boiler_dhw_charge_pump,binary_sensor.boiler_dhw_chargepump,5,9,1,63,1 +"GB212",boiler,131,dhw.mixertemp,mixer temperature,uint16 (>=0<=3199),C,false,sensor.boiler_dhw_mixer_temperature,sensor.boiler_dhw_mixertemp,5,9,1/10,64,1 +"GB212",boiler,131,dhw.cylmiddletemp,cylinder middle temperature (TS3),uint16 (>=0<=3199),C,false,sensor.boiler_dhw_cylinder_middle_temperature_(TS3),sensor.boiler_dhw_cylmiddletemp,5,9,1/10,65,1 +"GB212",boiler,131,dhw.starts,starts,uint24 (>=0<=16777214), ,false,sensor.boiler_dhw_starts,sensor.boiler_dhw_starts,5,9,1,66,2 +"GB212",boiler,131,dhw.workm,active time,time (>=0<=16777214),minutes,false,sensor.boiler_dhw_active_time,sensor.boiler_dhw_workm,5,9,1,68,2 "GB212",boiler,131,nompower,nominal Power,uint8 (>=0<=254),kW,true,number.boiler_nominal_Power,number.boiler_nompower,5,0,1,270,1 "GB212",boiler,131,nrgtotal,total energy,uint24 (>=0<=167772),kWh,false,sensor.boiler_total_energy,sensor.boiler_nrgtotal,5,0,1/100,83,2 "GB212",boiler,131,nrgheat,energy heating,uint24 (>=0<=10000000),kWh,true,number.boiler_energy_heating,number.boiler_nrgheat,5,0,1/100,85,2 @@ -1528,9 +1540,9 @@ device name,device type,product id,shortname,fullname,type [options...] \| (min/ "GC7000F",boiler,132,meterheat,meter heating,uint24 (>=0<=1677721),kWh,false,sensor.boiler_meter_heating,sensor.boiler_meterheat,5,0,1/10,95,2 "GC7000F",boiler,132,dhw.meter,meter,uint24 (>=0<=1677721),kWh,false,sensor.boiler_dhw_meter,sensor.boiler_dhw_meter,5,9,1/10,2,2 "GC7000F",boiler,132,gasmeterheat,gas meter heating,uint24 (>=0<=1677721),kWh,false,sensor.boiler_gas_meter_heating,sensor.boiler_gasmeterheat,5,0,1/10,266,2 -"GC7000F",boiler,132,dhw.gasmeter,gas meter,uint24 (>=0<=1677721),kWh,false,sensor.boiler_dhw_gas_meter,sensor.boiler_dhw_gasmeter,5,9,1/10,69,2 +"GC7000F",boiler,132,dhw.gasmeter,gas meter,uint24 (>=0<=1677721),kWh,false,sensor.boiler_dhw_gas_meter,sensor.boiler_dhw_gasmeter,5,9,1/10,70,2 "GC7000F",boiler,132,nrgheat2,energy heating 2,uint24 (>=0<=1677721),kWh,false,sensor.boiler_energy_heating_2,sensor.boiler_nrgheat2,5,0,1/10,268,2 -"GC7000F",boiler,132,dhw.nrg2,energy 2,uint24 (>=0<=1677721),kWh,false,sensor.boiler_dhw_energy_2,sensor.boiler_dhw_nrg2,5,9,1/10,71,2 +"GC7000F",boiler,132,dhw.nrg2,energy 2,uint24 (>=0<=1677721),kWh,false,sensor.boiler_dhw_energy_2,sensor.boiler_dhw_nrg2,5,9,1/10,72,2 "GC7000F",boiler,132,dhw.tapactivated,turn on/off,boolean, ,true,switch.boiler_dhw_turn_on/off,switch.boiler_dhw_tapactivated,5,9,1,28,1 "GC7000F",boiler,132,dhw.settemp,set temperature,uint8 (>=0<=254),C,false,sensor.boiler_dhw_set_temperature,sensor.boiler_dhw_settemp,5,9,1,29,1 "GC7000F",boiler,132,dhw.seltemp,selected temperature,uint8 (>=0<=254),C,true,number.boiler_dhw_selected_temperature,number.boiler_dhw_seltemp,5,9,1,30,1 @@ -1566,10 +1578,11 @@ device name,device type,product id,shortname,fullname,type [options...] \| (min/ "GC7000F",boiler,132,dhw.tempok,temperature ok,boolean, ,false,binary_sensor.boiler_dhw_temperature_ok,binary_sensor.boiler_dhw_tempok,5,9,1,60,1 "GC7000F",boiler,132,dhw.active,active,boolean, ,false,binary_sensor.boiler_dhw_active,binary_sensor.boiler_dhw_active,5,9,1,61,1 "GC7000F",boiler,132,dhw.3wayvalve,3-way valve active,boolean, ,false,binary_sensor.boiler_dhw_3-way_valve_active,binary_sensor.boiler_dhw_3wayvalve,5,9,1,62,1 -"GC7000F",boiler,132,dhw.mixertemp,mixer temperature,uint16 (>=0<=3199),C,false,sensor.boiler_dhw_mixer_temperature,sensor.boiler_dhw_mixertemp,5,9,1/10,63,1 -"GC7000F",boiler,132,dhw.cylmiddletemp,cylinder middle temperature (TS3),uint16 (>=0<=3199),C,false,sensor.boiler_dhw_cylinder_middle_temperature_(TS3),sensor.boiler_dhw_cylmiddletemp,5,9,1/10,64,1 -"GC7000F",boiler,132,dhw.starts,starts,uint24 (>=0<=16777214), ,false,sensor.boiler_dhw_starts,sensor.boiler_dhw_starts,5,9,1,65,2 -"GC7000F",boiler,132,dhw.workm,active time,time (>=0<=16777214),minutes,false,sensor.boiler_dhw_active_time,sensor.boiler_dhw_workm,5,9,1,67,2 +"GC7000F",boiler,132,dhw.chargepump,charge pump,boolean, ,false,binary_sensor.boiler_dhw_charge_pump,binary_sensor.boiler_dhw_chargepump,5,9,1,63,1 +"GC7000F",boiler,132,dhw.mixertemp,mixer temperature,uint16 (>=0<=3199),C,false,sensor.boiler_dhw_mixer_temperature,sensor.boiler_dhw_mixertemp,5,9,1/10,64,1 +"GC7000F",boiler,132,dhw.cylmiddletemp,cylinder middle temperature (TS3),uint16 (>=0<=3199),C,false,sensor.boiler_dhw_cylinder_middle_temperature_(TS3),sensor.boiler_dhw_cylmiddletemp,5,9,1/10,65,1 +"GC7000F",boiler,132,dhw.starts,starts,uint24 (>=0<=16777214), ,false,sensor.boiler_dhw_starts,sensor.boiler_dhw_starts,5,9,1,66,2 +"GC7000F",boiler,132,dhw.workm,active time,time (>=0<=16777214),minutes,false,sensor.boiler_dhw_active_time,sensor.boiler_dhw_workm,5,9,1,68,2 "GC7000F",boiler,132,nompower,nominal Power,uint8 (>=0<=254),kW,true,number.boiler_nominal_Power,number.boiler_nompower,5,0,1,270,1 "GC7000F",boiler,132,nrgtotal,total energy,uint24 (>=0<=167772),kWh,false,sensor.boiler_total_energy,sensor.boiler_nrgtotal,5,0,1/100,83,2 "GC7000F",boiler,132,nrgheat,energy heating,uint24 (>=0<=10000000),kWh,true,number.boiler_energy_heating,number.boiler_nrgheat,5,0,1/100,85,2 @@ -1642,9 +1655,9 @@ device name,device type,product id,shortname,fullname,type [options...] \| (min/ "Logano GB125/KB195i, Logamatic MC110",boiler,133,meterheat,meter heating,uint24 (>=0<=1677721),kWh,false,sensor.boiler_meter_heating,sensor.boiler_meterheat,5,0,1/10,95,2 "Logano GB125/KB195i, Logamatic MC110",boiler,133,dhw.meter,meter,uint24 (>=0<=1677721),kWh,false,sensor.boiler_dhw_meter,sensor.boiler_dhw_meter,5,9,1/10,2,2 "Logano GB125/KB195i, Logamatic MC110",boiler,133,gasmeterheat,gas meter heating,uint24 (>=0<=1677721),kWh,false,sensor.boiler_gas_meter_heating,sensor.boiler_gasmeterheat,5,0,1/10,266,2 -"Logano GB125/KB195i, Logamatic MC110",boiler,133,dhw.gasmeter,gas meter,uint24 (>=0<=1677721),kWh,false,sensor.boiler_dhw_gas_meter,sensor.boiler_dhw_gasmeter,5,9,1/10,69,2 +"Logano GB125/KB195i, Logamatic MC110",boiler,133,dhw.gasmeter,gas meter,uint24 (>=0<=1677721),kWh,false,sensor.boiler_dhw_gas_meter,sensor.boiler_dhw_gasmeter,5,9,1/10,70,2 "Logano GB125/KB195i, Logamatic MC110",boiler,133,nrgheat2,energy heating 2,uint24 (>=0<=1677721),kWh,false,sensor.boiler_energy_heating_2,sensor.boiler_nrgheat2,5,0,1/10,268,2 -"Logano GB125/KB195i, Logamatic MC110",boiler,133,dhw.nrg2,energy 2,uint24 (>=0<=1677721),kWh,false,sensor.boiler_dhw_energy_2,sensor.boiler_dhw_nrg2,5,9,1/10,71,2 +"Logano GB125/KB195i, Logamatic MC110",boiler,133,dhw.nrg2,energy 2,uint24 (>=0<=1677721),kWh,false,sensor.boiler_dhw_energy_2,sensor.boiler_dhw_nrg2,5,9,1/10,72,2 "Logano GB125/KB195i, Logamatic MC110",boiler,133,dhw.tapactivated,turn on/off,boolean, ,true,switch.boiler_dhw_turn_on/off,switch.boiler_dhw_tapactivated,5,9,1,28,1 "Logano GB125/KB195i, Logamatic MC110",boiler,133,dhw.settemp,set temperature,uint8 (>=0<=254),C,false,sensor.boiler_dhw_set_temperature,sensor.boiler_dhw_settemp,5,9,1,29,1 "Logano GB125/KB195i, Logamatic MC110",boiler,133,dhw.seltemp,selected temperature,uint8 (>=0<=254),C,true,number.boiler_dhw_selected_temperature,number.boiler_dhw_seltemp,5,9,1,30,1 @@ -1680,10 +1693,11 @@ device name,device type,product id,shortname,fullname,type [options...] \| (min/ "Logano GB125/KB195i, Logamatic MC110",boiler,133,dhw.tempok,temperature ok,boolean, ,false,binary_sensor.boiler_dhw_temperature_ok,binary_sensor.boiler_dhw_tempok,5,9,1,60,1 "Logano GB125/KB195i, Logamatic MC110",boiler,133,dhw.active,active,boolean, ,false,binary_sensor.boiler_dhw_active,binary_sensor.boiler_dhw_active,5,9,1,61,1 "Logano GB125/KB195i, Logamatic MC110",boiler,133,dhw.3wayvalve,3-way valve active,boolean, ,false,binary_sensor.boiler_dhw_3-way_valve_active,binary_sensor.boiler_dhw_3wayvalve,5,9,1,62,1 -"Logano GB125/KB195i, Logamatic MC110",boiler,133,dhw.mixertemp,mixer temperature,uint16 (>=0<=3199),C,false,sensor.boiler_dhw_mixer_temperature,sensor.boiler_dhw_mixertemp,5,9,1/10,63,1 -"Logano GB125/KB195i, Logamatic MC110",boiler,133,dhw.cylmiddletemp,cylinder middle temperature (TS3),uint16 (>=0<=3199),C,false,sensor.boiler_dhw_cylinder_middle_temperature_(TS3),sensor.boiler_dhw_cylmiddletemp,5,9,1/10,64,1 -"Logano GB125/KB195i, Logamatic MC110",boiler,133,dhw.starts,starts,uint24 (>=0<=16777214), ,false,sensor.boiler_dhw_starts,sensor.boiler_dhw_starts,5,9,1,65,2 -"Logano GB125/KB195i, Logamatic MC110",boiler,133,dhw.workm,active time,time (>=0<=16777214),minutes,false,sensor.boiler_dhw_active_time,sensor.boiler_dhw_workm,5,9,1,67,2 +"Logano GB125/KB195i, Logamatic MC110",boiler,133,dhw.chargepump,charge pump,boolean, ,false,binary_sensor.boiler_dhw_charge_pump,binary_sensor.boiler_dhw_chargepump,5,9,1,63,1 +"Logano GB125/KB195i, Logamatic MC110",boiler,133,dhw.mixertemp,mixer temperature,uint16 (>=0<=3199),C,false,sensor.boiler_dhw_mixer_temperature,sensor.boiler_dhw_mixertemp,5,9,1/10,64,1 +"Logano GB125/KB195i, Logamatic MC110",boiler,133,dhw.cylmiddletemp,cylinder middle temperature (TS3),uint16 (>=0<=3199),C,false,sensor.boiler_dhw_cylinder_middle_temperature_(TS3),sensor.boiler_dhw_cylmiddletemp,5,9,1/10,65,1 +"Logano GB125/KB195i, Logamatic MC110",boiler,133,dhw.starts,starts,uint24 (>=0<=16777214), ,false,sensor.boiler_dhw_starts,sensor.boiler_dhw_starts,5,9,1,66,2 +"Logano GB125/KB195i, Logamatic MC110",boiler,133,dhw.workm,active time,time (>=0<=16777214),minutes,false,sensor.boiler_dhw_active_time,sensor.boiler_dhw_workm,5,9,1,68,2 "Logano GB125/KB195i, Logamatic MC110",boiler,133,nompower,nominal Power,uint8 (>=0<=254),kW,true,number.boiler_nominal_Power,number.boiler_nompower,5,0,1,270,1 "Logano GB125/KB195i, Logamatic MC110",boiler,133,nrgtotal,total energy,uint24 (>=0<=167772),kWh,false,sensor.boiler_total_energy,sensor.boiler_nrgtotal,5,0,1/100,83,2 "Logano GB125/KB195i, Logamatic MC110",boiler,133,nrgheat,energy heating,uint24 (>=0<=10000000),kWh,true,number.boiler_energy_heating,number.boiler_nrgheat,5,0,1/100,85,2 @@ -1756,9 +1770,9 @@ device name,device type,product id,shortname,fullname,type [options...] \| (min/ "Greenstar 30Ri Compact",boiler,154,meterheat,meter heating,uint24 (>=0<=1677721),kWh,false,sensor.boiler_meter_heating,sensor.boiler_meterheat,5,0,1/10,95,2 "Greenstar 30Ri Compact",boiler,154,dhw.meter,meter,uint24 (>=0<=1677721),kWh,false,sensor.boiler_dhw_meter,sensor.boiler_dhw_meter,5,9,1/10,2,2 "Greenstar 30Ri Compact",boiler,154,gasmeterheat,gas meter heating,uint24 (>=0<=1677721),kWh,false,sensor.boiler_gas_meter_heating,sensor.boiler_gasmeterheat,5,0,1/10,266,2 -"Greenstar 30Ri Compact",boiler,154,dhw.gasmeter,gas meter,uint24 (>=0<=1677721),kWh,false,sensor.boiler_dhw_gas_meter,sensor.boiler_dhw_gasmeter,5,9,1/10,69,2 +"Greenstar 30Ri Compact",boiler,154,dhw.gasmeter,gas meter,uint24 (>=0<=1677721),kWh,false,sensor.boiler_dhw_gas_meter,sensor.boiler_dhw_gasmeter,5,9,1/10,70,2 "Greenstar 30Ri Compact",boiler,154,nrgheat2,energy heating 2,uint24 (>=0<=1677721),kWh,false,sensor.boiler_energy_heating_2,sensor.boiler_nrgheat2,5,0,1/10,268,2 -"Greenstar 30Ri Compact",boiler,154,dhw.nrg2,energy 2,uint24 (>=0<=1677721),kWh,false,sensor.boiler_dhw_energy_2,sensor.boiler_dhw_nrg2,5,9,1/10,71,2 +"Greenstar 30Ri Compact",boiler,154,dhw.nrg2,energy 2,uint24 (>=0<=1677721),kWh,false,sensor.boiler_dhw_energy_2,sensor.boiler_dhw_nrg2,5,9,1/10,72,2 "Greenstar 30Ri Compact",boiler,154,dhw.tapactivated,turn on/off,boolean, ,true,switch.boiler_dhw_turn_on/off,switch.boiler_dhw_tapactivated,5,9,1,28,1 "Greenstar 30Ri Compact",boiler,154,dhw.settemp,set temperature,uint8 (>=0<=254),C,false,sensor.boiler_dhw_set_temperature,sensor.boiler_dhw_settemp,5,9,1,29,1 "Greenstar 30Ri Compact",boiler,154,dhw.seltemp,selected temperature,uint8 (>=0<=254),C,true,number.boiler_dhw_selected_temperature,number.boiler_dhw_seltemp,5,9,1,30,1 @@ -1794,10 +1808,11 @@ device name,device type,product id,shortname,fullname,type [options...] \| (min/ "Greenstar 30Ri Compact",boiler,154,dhw.tempok,temperature ok,boolean, ,false,binary_sensor.boiler_dhw_temperature_ok,binary_sensor.boiler_dhw_tempok,5,9,1,60,1 "Greenstar 30Ri Compact",boiler,154,dhw.active,active,boolean, ,false,binary_sensor.boiler_dhw_active,binary_sensor.boiler_dhw_active,5,9,1,61,1 "Greenstar 30Ri Compact",boiler,154,dhw.3wayvalve,3-way valve active,boolean, ,false,binary_sensor.boiler_dhw_3-way_valve_active,binary_sensor.boiler_dhw_3wayvalve,5,9,1,62,1 -"Greenstar 30Ri Compact",boiler,154,dhw.mixertemp,mixer temperature,uint16 (>=0<=3199),C,false,sensor.boiler_dhw_mixer_temperature,sensor.boiler_dhw_mixertemp,5,9,1/10,63,1 -"Greenstar 30Ri Compact",boiler,154,dhw.cylmiddletemp,cylinder middle temperature (TS3),uint16 (>=0<=3199),C,false,sensor.boiler_dhw_cylinder_middle_temperature_(TS3),sensor.boiler_dhw_cylmiddletemp,5,9,1/10,64,1 -"Greenstar 30Ri Compact",boiler,154,dhw.starts,starts,uint24 (>=0<=16777214), ,false,sensor.boiler_dhw_starts,sensor.boiler_dhw_starts,5,9,1,65,2 -"Greenstar 30Ri Compact",boiler,154,dhw.workm,active time,time (>=0<=16777214),minutes,false,sensor.boiler_dhw_active_time,sensor.boiler_dhw_workm,5,9,1,67,2 +"Greenstar 30Ri Compact",boiler,154,dhw.chargepump,charge pump,boolean, ,false,binary_sensor.boiler_dhw_charge_pump,binary_sensor.boiler_dhw_chargepump,5,9,1,63,1 +"Greenstar 30Ri Compact",boiler,154,dhw.mixertemp,mixer temperature,uint16 (>=0<=3199),C,false,sensor.boiler_dhw_mixer_temperature,sensor.boiler_dhw_mixertemp,5,9,1/10,64,1 +"Greenstar 30Ri Compact",boiler,154,dhw.cylmiddletemp,cylinder middle temperature (TS3),uint16 (>=0<=3199),C,false,sensor.boiler_dhw_cylinder_middle_temperature_(TS3),sensor.boiler_dhw_cylmiddletemp,5,9,1/10,65,1 +"Greenstar 30Ri Compact",boiler,154,dhw.starts,starts,uint24 (>=0<=16777214), ,false,sensor.boiler_dhw_starts,sensor.boiler_dhw_starts,5,9,1,66,2 +"Greenstar 30Ri Compact",boiler,154,dhw.workm,active time,time (>=0<=16777214),minutes,false,sensor.boiler_dhw_active_time,sensor.boiler_dhw_workm,5,9,1,68,2 "Greenstar 30Ri Compact",boiler,154,nompower,nominal Power,uint8 (>=0<=254),kW,true,number.boiler_nominal_Power,number.boiler_nompower,5,0,1,270,1 "Greenstar 30Ri Compact",boiler,154,nrgtotal,total energy,uint24 (>=0<=167772),kWh,false,sensor.boiler_total_energy,sensor.boiler_nrgtotal,5,0,1/100,83,2 "Greenstar 30Ri Compact",boiler,154,nrgheat,energy heating,uint24 (>=0<=10000000),kWh,true,number.boiler_energy_heating,number.boiler_nrgheat,5,0,1/100,85,2 @@ -1870,9 +1885,9 @@ device name,device type,product id,shortname,fullname,type [options...] \| (min/ "Suprapur-o",boiler,155,meterheat,meter heating,uint24 (>=0<=1677721),kWh,false,sensor.boiler_meter_heating,sensor.boiler_meterheat,5,0,1/10,95,2 "Suprapur-o",boiler,155,dhw.meter,meter,uint24 (>=0<=1677721),kWh,false,sensor.boiler_dhw_meter,sensor.boiler_dhw_meter,5,9,1/10,2,2 "Suprapur-o",boiler,155,gasmeterheat,gas meter heating,uint24 (>=0<=1677721),kWh,false,sensor.boiler_gas_meter_heating,sensor.boiler_gasmeterheat,5,0,1/10,266,2 -"Suprapur-o",boiler,155,dhw.gasmeter,gas meter,uint24 (>=0<=1677721),kWh,false,sensor.boiler_dhw_gas_meter,sensor.boiler_dhw_gasmeter,5,9,1/10,69,2 +"Suprapur-o",boiler,155,dhw.gasmeter,gas meter,uint24 (>=0<=1677721),kWh,false,sensor.boiler_dhw_gas_meter,sensor.boiler_dhw_gasmeter,5,9,1/10,70,2 "Suprapur-o",boiler,155,nrgheat2,energy heating 2,uint24 (>=0<=1677721),kWh,false,sensor.boiler_energy_heating_2,sensor.boiler_nrgheat2,5,0,1/10,268,2 -"Suprapur-o",boiler,155,dhw.nrg2,energy 2,uint24 (>=0<=1677721),kWh,false,sensor.boiler_dhw_energy_2,sensor.boiler_dhw_nrg2,5,9,1/10,71,2 +"Suprapur-o",boiler,155,dhw.nrg2,energy 2,uint24 (>=0<=1677721),kWh,false,sensor.boiler_dhw_energy_2,sensor.boiler_dhw_nrg2,5,9,1/10,72,2 "Suprapur-o",boiler,155,dhw.tapactivated,turn on/off,boolean, ,true,switch.boiler_dhw_turn_on/off,switch.boiler_dhw_tapactivated,5,9,1,28,1 "Suprapur-o",boiler,155,dhw.settemp,set temperature,uint8 (>=0<=254),C,false,sensor.boiler_dhw_set_temperature,sensor.boiler_dhw_settemp,5,9,1,29,1 "Suprapur-o",boiler,155,dhw.seltemp,selected temperature,uint8 (>=0<=254),C,true,number.boiler_dhw_selected_temperature,number.boiler_dhw_seltemp,5,9,1,30,1 @@ -1908,10 +1923,11 @@ device name,device type,product id,shortname,fullname,type [options...] \| (min/ "Suprapur-o",boiler,155,dhw.tempok,temperature ok,boolean, ,false,binary_sensor.boiler_dhw_temperature_ok,binary_sensor.boiler_dhw_tempok,5,9,1,60,1 "Suprapur-o",boiler,155,dhw.active,active,boolean, ,false,binary_sensor.boiler_dhw_active,binary_sensor.boiler_dhw_active,5,9,1,61,1 "Suprapur-o",boiler,155,dhw.3wayvalve,3-way valve active,boolean, ,false,binary_sensor.boiler_dhw_3-way_valve_active,binary_sensor.boiler_dhw_3wayvalve,5,9,1,62,1 -"Suprapur-o",boiler,155,dhw.mixertemp,mixer temperature,uint16 (>=0<=3199),C,false,sensor.boiler_dhw_mixer_temperature,sensor.boiler_dhw_mixertemp,5,9,1/10,63,1 -"Suprapur-o",boiler,155,dhw.cylmiddletemp,cylinder middle temperature (TS3),uint16 (>=0<=3199),C,false,sensor.boiler_dhw_cylinder_middle_temperature_(TS3),sensor.boiler_dhw_cylmiddletemp,5,9,1/10,64,1 -"Suprapur-o",boiler,155,dhw.starts,starts,uint24 (>=0<=16777214), ,false,sensor.boiler_dhw_starts,sensor.boiler_dhw_starts,5,9,1,65,2 -"Suprapur-o",boiler,155,dhw.workm,active time,time (>=0<=16777214),minutes,false,sensor.boiler_dhw_active_time,sensor.boiler_dhw_workm,5,9,1,67,2 +"Suprapur-o",boiler,155,dhw.chargepump,charge pump,boolean, ,false,binary_sensor.boiler_dhw_charge_pump,binary_sensor.boiler_dhw_chargepump,5,9,1,63,1 +"Suprapur-o",boiler,155,dhw.mixertemp,mixer temperature,uint16 (>=0<=3199),C,false,sensor.boiler_dhw_mixer_temperature,sensor.boiler_dhw_mixertemp,5,9,1/10,64,1 +"Suprapur-o",boiler,155,dhw.cylmiddletemp,cylinder middle temperature (TS3),uint16 (>=0<=3199),C,false,sensor.boiler_dhw_cylinder_middle_temperature_(TS3),sensor.boiler_dhw_cylmiddletemp,5,9,1/10,65,1 +"Suprapur-o",boiler,155,dhw.starts,starts,uint24 (>=0<=16777214), ,false,sensor.boiler_dhw_starts,sensor.boiler_dhw_starts,5,9,1,66,2 +"Suprapur-o",boiler,155,dhw.workm,active time,time (>=0<=16777214),minutes,false,sensor.boiler_dhw_active_time,sensor.boiler_dhw_workm,5,9,1,68,2 "Suprapur-o",boiler,155,nompower,nominal Power,uint8 (>=0<=254),kW,true,number.boiler_nominal_Power,number.boiler_nompower,5,0,1,270,1 "Suprapur-o",boiler,155,nrgtotal,total energy,uint24 (>=0<=167772),kWh,false,sensor.boiler_total_energy,sensor.boiler_nrgtotal,5,0,1/100,83,2 "Suprapur-o",boiler,155,nrgheat,energy heating,uint24 (>=0<=10000000),kWh,true,number.boiler_energy_heating,number.boiler_nrgheat,5,0,1/100,85,2 @@ -1984,9 +2000,9 @@ device name,device type,product id,shortname,fullname,type [options...] \| (min/ "Cerapur Aero",boiler,167,meterheat,meter heating,uint24 (>=0<=1677721),kWh,false,sensor.boiler_meter_heating,sensor.boiler_meterheat,5,0,1/10,95,2 "Cerapur Aero",boiler,167,dhw.meter,meter,uint24 (>=0<=1677721),kWh,false,sensor.boiler_dhw_meter,sensor.boiler_dhw_meter,5,9,1/10,2,2 "Cerapur Aero",boiler,167,gasmeterheat,gas meter heating,uint24 (>=0<=1677721),kWh,false,sensor.boiler_gas_meter_heating,sensor.boiler_gasmeterheat,5,0,1/10,266,2 -"Cerapur Aero",boiler,167,dhw.gasmeter,gas meter,uint24 (>=0<=1677721),kWh,false,sensor.boiler_dhw_gas_meter,sensor.boiler_dhw_gasmeter,5,9,1/10,69,2 +"Cerapur Aero",boiler,167,dhw.gasmeter,gas meter,uint24 (>=0<=1677721),kWh,false,sensor.boiler_dhw_gas_meter,sensor.boiler_dhw_gasmeter,5,9,1/10,70,2 "Cerapur Aero",boiler,167,nrgheat2,energy heating 2,uint24 (>=0<=1677721),kWh,false,sensor.boiler_energy_heating_2,sensor.boiler_nrgheat2,5,0,1/10,268,2 -"Cerapur Aero",boiler,167,dhw.nrg2,energy 2,uint24 (>=0<=1677721),kWh,false,sensor.boiler_dhw_energy_2,sensor.boiler_dhw_nrg2,5,9,1/10,71,2 +"Cerapur Aero",boiler,167,dhw.nrg2,energy 2,uint24 (>=0<=1677721),kWh,false,sensor.boiler_dhw_energy_2,sensor.boiler_dhw_nrg2,5,9,1/10,72,2 "Cerapur Aero",boiler,167,dhw.tapactivated,turn on/off,boolean, ,true,switch.boiler_dhw_turn_on/off,switch.boiler_dhw_tapactivated,5,9,1,28,1 "Cerapur Aero",boiler,167,dhw.settemp,set temperature,uint8 (>=0<=254),C,false,sensor.boiler_dhw_set_temperature,sensor.boiler_dhw_settemp,5,9,1,29,1 "Cerapur Aero",boiler,167,dhw.seltemp,selected temperature,uint8 (>=0<=254),C,true,number.boiler_dhw_selected_temperature,number.boiler_dhw_seltemp,5,9,1,30,1 @@ -2022,10 +2038,11 @@ device name,device type,product id,shortname,fullname,type [options...] \| (min/ "Cerapur Aero",boiler,167,dhw.tempok,temperature ok,boolean, ,false,binary_sensor.boiler_dhw_temperature_ok,binary_sensor.boiler_dhw_tempok,5,9,1,60,1 "Cerapur Aero",boiler,167,dhw.active,active,boolean, ,false,binary_sensor.boiler_dhw_active,binary_sensor.boiler_dhw_active,5,9,1,61,1 "Cerapur Aero",boiler,167,dhw.3wayvalve,3-way valve active,boolean, ,false,binary_sensor.boiler_dhw_3-way_valve_active,binary_sensor.boiler_dhw_3wayvalve,5,9,1,62,1 -"Cerapur Aero",boiler,167,dhw.mixertemp,mixer temperature,uint16 (>=0<=3199),C,false,sensor.boiler_dhw_mixer_temperature,sensor.boiler_dhw_mixertemp,5,9,1/10,63,1 -"Cerapur Aero",boiler,167,dhw.cylmiddletemp,cylinder middle temperature (TS3),uint16 (>=0<=3199),C,false,sensor.boiler_dhw_cylinder_middle_temperature_(TS3),sensor.boiler_dhw_cylmiddletemp,5,9,1/10,64,1 -"Cerapur Aero",boiler,167,dhw.starts,starts,uint24 (>=0<=16777214), ,false,sensor.boiler_dhw_starts,sensor.boiler_dhw_starts,5,9,1,65,2 -"Cerapur Aero",boiler,167,dhw.workm,active time,time (>=0<=16777214),minutes,false,sensor.boiler_dhw_active_time,sensor.boiler_dhw_workm,5,9,1,67,2 +"Cerapur Aero",boiler,167,dhw.chargepump,charge pump,boolean, ,false,binary_sensor.boiler_dhw_charge_pump,binary_sensor.boiler_dhw_chargepump,5,9,1,63,1 +"Cerapur Aero",boiler,167,dhw.mixertemp,mixer temperature,uint16 (>=0<=3199),C,false,sensor.boiler_dhw_mixer_temperature,sensor.boiler_dhw_mixertemp,5,9,1/10,64,1 +"Cerapur Aero",boiler,167,dhw.cylmiddletemp,cylinder middle temperature (TS3),uint16 (>=0<=3199),C,false,sensor.boiler_dhw_cylinder_middle_temperature_(TS3),sensor.boiler_dhw_cylmiddletemp,5,9,1/10,65,1 +"Cerapur Aero",boiler,167,dhw.starts,starts,uint24 (>=0<=16777214), ,false,sensor.boiler_dhw_starts,sensor.boiler_dhw_starts,5,9,1,66,2 +"Cerapur Aero",boiler,167,dhw.workm,active time,time (>=0<=16777214),minutes,false,sensor.boiler_dhw_active_time,sensor.boiler_dhw_workm,5,9,1,68,2 "Cerapur Aero",boiler,167,nompower,nominal Power,uint8 (>=0<=254),kW,true,number.boiler_nominal_Power,number.boiler_nompower,5,0,1,270,1 "Cerapur Aero",boiler,167,nrgtotal,total energy,uint24 (>=0<=167772),kWh,false,sensor.boiler_total_energy,sensor.boiler_nrgtotal,5,0,1/100,83,2 "Cerapur Aero",boiler,167,nrgheat,energy heating,uint24 (>=0<=10000000),kWh,true,number.boiler_energy_heating,number.boiler_nrgheat,5,0,1/100,85,2 @@ -2098,9 +2115,9 @@ device name,device type,product id,shortname,fullname,type [options...] \| (min/ "Hybrid Heatpump",boiler,168,meterheat,meter heating,uint24 (>=0<=1677721),kWh,false,sensor.boiler_meter_heating,sensor.boiler_meterheat,5,0,1/10,95,2 "Hybrid Heatpump",boiler,168,dhw.meter,meter,uint24 (>=0<=1677721),kWh,false,sensor.boiler_dhw_meter,sensor.boiler_dhw_meter,5,9,1/10,2,2 "Hybrid Heatpump",boiler,168,gasmeterheat,gas meter heating,uint24 (>=0<=1677721),kWh,false,sensor.boiler_gas_meter_heating,sensor.boiler_gasmeterheat,5,0,1/10,266,2 -"Hybrid Heatpump",boiler,168,dhw.gasmeter,gas meter,uint24 (>=0<=1677721),kWh,false,sensor.boiler_dhw_gas_meter,sensor.boiler_dhw_gasmeter,5,9,1/10,69,2 +"Hybrid Heatpump",boiler,168,dhw.gasmeter,gas meter,uint24 (>=0<=1677721),kWh,false,sensor.boiler_dhw_gas_meter,sensor.boiler_dhw_gasmeter,5,9,1/10,70,2 "Hybrid Heatpump",boiler,168,nrgheat2,energy heating 2,uint24 (>=0<=1677721),kWh,false,sensor.boiler_energy_heating_2,sensor.boiler_nrgheat2,5,0,1/10,268,2 -"Hybrid Heatpump",boiler,168,dhw.nrg2,energy 2,uint24 (>=0<=1677721),kWh,false,sensor.boiler_dhw_energy_2,sensor.boiler_dhw_nrg2,5,9,1/10,71,2 +"Hybrid Heatpump",boiler,168,dhw.nrg2,energy 2,uint24 (>=0<=1677721),kWh,false,sensor.boiler_dhw_energy_2,sensor.boiler_dhw_nrg2,5,9,1/10,72,2 "Hybrid Heatpump",boiler,168,dhw.tapactivated,turn on/off,boolean, ,true,switch.boiler_dhw_turn_on/off,switch.boiler_dhw_tapactivated,5,9,1,28,1 "Hybrid Heatpump",boiler,168,dhw.settemp,set temperature,uint8 (>=0<=254),C,false,sensor.boiler_dhw_set_temperature,sensor.boiler_dhw_settemp,5,9,1,29,1 "Hybrid Heatpump",boiler,168,dhw.seltemp,selected temperature,uint8 (>=0<=254),C,true,number.boiler_dhw_selected_temperature,number.boiler_dhw_seltemp,5,9,1,30,1 @@ -2136,10 +2153,11 @@ device name,device type,product id,shortname,fullname,type [options...] \| (min/ "Hybrid Heatpump",boiler,168,dhw.tempok,temperature ok,boolean, ,false,binary_sensor.boiler_dhw_temperature_ok,binary_sensor.boiler_dhw_tempok,5,9,1,60,1 "Hybrid Heatpump",boiler,168,dhw.active,active,boolean, ,false,binary_sensor.boiler_dhw_active,binary_sensor.boiler_dhw_active,5,9,1,61,1 "Hybrid Heatpump",boiler,168,dhw.3wayvalve,3-way valve active,boolean, ,false,binary_sensor.boiler_dhw_3-way_valve_active,binary_sensor.boiler_dhw_3wayvalve,5,9,1,62,1 -"Hybrid Heatpump",boiler,168,dhw.mixertemp,mixer temperature,uint16 (>=0<=3199),C,false,sensor.boiler_dhw_mixer_temperature,sensor.boiler_dhw_mixertemp,5,9,1/10,63,1 -"Hybrid Heatpump",boiler,168,dhw.cylmiddletemp,cylinder middle temperature (TS3),uint16 (>=0<=3199),C,false,sensor.boiler_dhw_cylinder_middle_temperature_(TS3),sensor.boiler_dhw_cylmiddletemp,5,9,1/10,64,1 -"Hybrid Heatpump",boiler,168,dhw.starts,starts,uint24 (>=0<=16777214), ,false,sensor.boiler_dhw_starts,sensor.boiler_dhw_starts,5,9,1,65,2 -"Hybrid Heatpump",boiler,168,dhw.workm,active time,time (>=0<=16777214),minutes,false,sensor.boiler_dhw_active_time,sensor.boiler_dhw_workm,5,9,1,67,2 +"Hybrid Heatpump",boiler,168,dhw.chargepump,charge pump,boolean, ,false,binary_sensor.boiler_dhw_charge_pump,binary_sensor.boiler_dhw_chargepump,5,9,1,63,1 +"Hybrid Heatpump",boiler,168,dhw.mixertemp,mixer temperature,uint16 (>=0<=3199),C,false,sensor.boiler_dhw_mixer_temperature,sensor.boiler_dhw_mixertemp,5,9,1/10,64,1 +"Hybrid Heatpump",boiler,168,dhw.cylmiddletemp,cylinder middle temperature (TS3),uint16 (>=0<=3199),C,false,sensor.boiler_dhw_cylinder_middle_temperature_(TS3),sensor.boiler_dhw_cylmiddletemp,5,9,1/10,65,1 +"Hybrid Heatpump",boiler,168,dhw.starts,starts,uint24 (>=0<=16777214), ,false,sensor.boiler_dhw_starts,sensor.boiler_dhw_starts,5,9,1,66,2 +"Hybrid Heatpump",boiler,168,dhw.workm,active time,time (>=0<=16777214),minutes,false,sensor.boiler_dhw_active_time,sensor.boiler_dhw_workm,5,9,1,68,2 "Hybrid Heatpump",boiler,168,nompower,nominal Power,uint8 (>=0<=254),kW,true,number.boiler_nominal_Power,number.boiler_nompower,5,0,1,270,1 "Hybrid Heatpump",boiler,168,nrgtotal,total energy,uint24 (>=0<=167772),kWh,false,sensor.boiler_total_energy,sensor.boiler_nrgtotal,5,0,1/100,83,2 "Hybrid Heatpump",boiler,168,nrgheat,energy heating,uint24 (>=0<=10000000),kWh,true,number.boiler_energy_heating,number.boiler_nrgheat,5,0,1/100,85,2 @@ -2212,9 +2230,9 @@ device name,device type,product id,shortname,fullname,type [options...] \| (min/ "Logano GB212",boiler,170,meterheat,meter heating,uint24 (>=0<=1677721),kWh,false,sensor.boiler_meter_heating,sensor.boiler_meterheat,5,0,1/10,95,2 "Logano GB212",boiler,170,dhw.meter,meter,uint24 (>=0<=1677721),kWh,false,sensor.boiler_dhw_meter,sensor.boiler_dhw_meter,5,9,1/10,2,2 "Logano GB212",boiler,170,gasmeterheat,gas meter heating,uint24 (>=0<=1677721),kWh,false,sensor.boiler_gas_meter_heating,sensor.boiler_gasmeterheat,5,0,1/10,266,2 -"Logano GB212",boiler,170,dhw.gasmeter,gas meter,uint24 (>=0<=1677721),kWh,false,sensor.boiler_dhw_gas_meter,sensor.boiler_dhw_gasmeter,5,9,1/10,69,2 +"Logano GB212",boiler,170,dhw.gasmeter,gas meter,uint24 (>=0<=1677721),kWh,false,sensor.boiler_dhw_gas_meter,sensor.boiler_dhw_gasmeter,5,9,1/10,70,2 "Logano GB212",boiler,170,nrgheat2,energy heating 2,uint24 (>=0<=1677721),kWh,false,sensor.boiler_energy_heating_2,sensor.boiler_nrgheat2,5,0,1/10,268,2 -"Logano GB212",boiler,170,dhw.nrg2,energy 2,uint24 (>=0<=1677721),kWh,false,sensor.boiler_dhw_energy_2,sensor.boiler_dhw_nrg2,5,9,1/10,71,2 +"Logano GB212",boiler,170,dhw.nrg2,energy 2,uint24 (>=0<=1677721),kWh,false,sensor.boiler_dhw_energy_2,sensor.boiler_dhw_nrg2,5,9,1/10,72,2 "Logano GB212",boiler,170,dhw.tapactivated,turn on/off,boolean, ,true,switch.boiler_dhw_turn_on/off,switch.boiler_dhw_tapactivated,5,9,1,28,1 "Logano GB212",boiler,170,dhw.settemp,set temperature,uint8 (>=0<=254),C,false,sensor.boiler_dhw_set_temperature,sensor.boiler_dhw_settemp,5,9,1,29,1 "Logano GB212",boiler,170,dhw.seltemp,selected temperature,uint8 (>=0<=254),C,true,number.boiler_dhw_selected_temperature,number.boiler_dhw_seltemp,5,9,1,30,1 @@ -2250,10 +2268,11 @@ device name,device type,product id,shortname,fullname,type [options...] \| (min/ "Logano GB212",boiler,170,dhw.tempok,temperature ok,boolean, ,false,binary_sensor.boiler_dhw_temperature_ok,binary_sensor.boiler_dhw_tempok,5,9,1,60,1 "Logano GB212",boiler,170,dhw.active,active,boolean, ,false,binary_sensor.boiler_dhw_active,binary_sensor.boiler_dhw_active,5,9,1,61,1 "Logano GB212",boiler,170,dhw.3wayvalve,3-way valve active,boolean, ,false,binary_sensor.boiler_dhw_3-way_valve_active,binary_sensor.boiler_dhw_3wayvalve,5,9,1,62,1 -"Logano GB212",boiler,170,dhw.mixertemp,mixer temperature,uint16 (>=0<=3199),C,false,sensor.boiler_dhw_mixer_temperature,sensor.boiler_dhw_mixertemp,5,9,1/10,63,1 -"Logano GB212",boiler,170,dhw.cylmiddletemp,cylinder middle temperature (TS3),uint16 (>=0<=3199),C,false,sensor.boiler_dhw_cylinder_middle_temperature_(TS3),sensor.boiler_dhw_cylmiddletemp,5,9,1/10,64,1 -"Logano GB212",boiler,170,dhw.starts,starts,uint24 (>=0<=16777214), ,false,sensor.boiler_dhw_starts,sensor.boiler_dhw_starts,5,9,1,65,2 -"Logano GB212",boiler,170,dhw.workm,active time,time (>=0<=16777214),minutes,false,sensor.boiler_dhw_active_time,sensor.boiler_dhw_workm,5,9,1,67,2 +"Logano GB212",boiler,170,dhw.chargepump,charge pump,boolean, ,false,binary_sensor.boiler_dhw_charge_pump,binary_sensor.boiler_dhw_chargepump,5,9,1,63,1 +"Logano GB212",boiler,170,dhw.mixertemp,mixer temperature,uint16 (>=0<=3199),C,false,sensor.boiler_dhw_mixer_temperature,sensor.boiler_dhw_mixertemp,5,9,1/10,64,1 +"Logano GB212",boiler,170,dhw.cylmiddletemp,cylinder middle temperature (TS3),uint16 (>=0<=3199),C,false,sensor.boiler_dhw_cylinder_middle_temperature_(TS3),sensor.boiler_dhw_cylmiddletemp,5,9,1/10,65,1 +"Logano GB212",boiler,170,dhw.starts,starts,uint24 (>=0<=16777214), ,false,sensor.boiler_dhw_starts,sensor.boiler_dhw_starts,5,9,1,66,2 +"Logano GB212",boiler,170,dhw.workm,active time,time (>=0<=16777214),minutes,false,sensor.boiler_dhw_active_time,sensor.boiler_dhw_workm,5,9,1,68,2 "Logano GB212",boiler,170,nompower,nominal Power,uint8 (>=0<=254),kW,true,number.boiler_nominal_Power,number.boiler_nompower,5,0,1,270,1 "Logano GB212",boiler,170,nrgtotal,total energy,uint24 (>=0<=167772),kWh,false,sensor.boiler_total_energy,sensor.boiler_nrgtotal,5,0,1/100,83,2 "Logano GB212",boiler,170,nrgheat,energy heating,uint24 (>=0<=10000000),kWh,true,number.boiler_energy_heating,number.boiler_nrgheat,5,0,1/100,85,2 @@ -2461,10 +2480,11 @@ device name,device type,product id,shortname,fullname,type [options...] \| (min/ "Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i",boiler,172,dhw.tempok,temperature ok,boolean, ,false,binary_sensor.boiler_dhw_temperature_ok,binary_sensor.boiler_dhw_tempok,5,9,1,60,1 "Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i",boiler,172,dhw.active,active,boolean, ,false,binary_sensor.boiler_dhw_active,binary_sensor.boiler_dhw_active,5,9,1,61,1 "Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i",boiler,172,dhw.3wayvalve,3-way valve active,boolean, ,false,binary_sensor.boiler_dhw_3-way_valve_active,binary_sensor.boiler_dhw_3wayvalve,5,9,1,62,1 -"Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i",boiler,172,dhw.mixertemp,mixer temperature,uint16 (>=0<=3199),C,false,sensor.boiler_dhw_mixer_temperature,sensor.boiler_dhw_mixertemp,5,9,1/10,63,1 -"Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i",boiler,172,dhw.cylmiddletemp,cylinder middle temperature (TS3),uint16 (>=0<=3199),C,false,sensor.boiler_dhw_cylinder_middle_temperature_(TS3),sensor.boiler_dhw_cylmiddletemp,5,9,1/10,64,1 -"Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i",boiler,172,dhw.starts,starts,uint24 (>=0<=16777214), ,false,sensor.boiler_dhw_starts,sensor.boiler_dhw_starts,5,9,1,65,2 -"Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i",boiler,172,dhw.workm,active time,time (>=0<=16777214),minutes,false,sensor.boiler_dhw_active_time,sensor.boiler_dhw_workm,5,9,1,67,2 +"Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i",boiler,172,dhw.chargepump,charge pump,boolean, ,false,binary_sensor.boiler_dhw_charge_pump,binary_sensor.boiler_dhw_chargepump,5,9,1,63,1 +"Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i",boiler,172,dhw.mixertemp,mixer temperature,uint16 (>=0<=3199),C,false,sensor.boiler_dhw_mixer_temperature,sensor.boiler_dhw_mixertemp,5,9,1/10,64,1 +"Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i",boiler,172,dhw.cylmiddletemp,cylinder middle temperature (TS3),uint16 (>=0<=3199),C,false,sensor.boiler_dhw_cylinder_middle_temperature_(TS3),sensor.boiler_dhw_cylmiddletemp,5,9,1/10,65,1 +"Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i",boiler,172,dhw.starts,starts,uint24 (>=0<=16777214), ,false,sensor.boiler_dhw_starts,sensor.boiler_dhw_starts,5,9,1,66,2 +"Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i",boiler,172,dhw.workm,active time,time (>=0<=16777214),minutes,false,sensor.boiler_dhw_active_time,sensor.boiler_dhw_workm,5,9,1,68,2 "Geo 5xx",boiler,173,reset,reset,cmd [-\|maintenance\|error\|history\|message], ,true,sensor.boiler_reset,sensor.boiler_reset,5,0,1,0,1 "Geo 5xx",boiler,173,heatingoff,force heating off,boolean, ,true,switch.boiler_force_heating_off,switch.boiler_heatingoff,5,0,1,1,1 "Geo 5xx",boiler,173,heatingactive,heating active,boolean, ,false,binary_sensor.boiler_heating_active,binary_sensor.boiler_heatingactive,5,0,1,2,1 @@ -2668,10 +2688,11 @@ device name,device type,product id,shortname,fullname,type [options...] \| (min/ "Geo 5xx",boiler,173,dhw.tempok,temperature ok,boolean, ,false,binary_sensor.boiler_dhw_temperature_ok,binary_sensor.boiler_dhw_tempok,5,9,1,60,1 "Geo 5xx",boiler,173,dhw.active,active,boolean, ,false,binary_sensor.boiler_dhw_active,binary_sensor.boiler_dhw_active,5,9,1,61,1 "Geo 5xx",boiler,173,dhw.3wayvalve,3-way valve active,boolean, ,false,binary_sensor.boiler_dhw_3-way_valve_active,binary_sensor.boiler_dhw_3wayvalve,5,9,1,62,1 -"Geo 5xx",boiler,173,dhw.mixertemp,mixer temperature,uint16 (>=0<=3199),C,false,sensor.boiler_dhw_mixer_temperature,sensor.boiler_dhw_mixertemp,5,9,1/10,63,1 -"Geo 5xx",boiler,173,dhw.cylmiddletemp,cylinder middle temperature (TS3),uint16 (>=0<=3199),C,false,sensor.boiler_dhw_cylinder_middle_temperature_(TS3),sensor.boiler_dhw_cylmiddletemp,5,9,1/10,64,1 -"Geo 5xx",boiler,173,dhw.starts,starts,uint24 (>=0<=16777214), ,false,sensor.boiler_dhw_starts,sensor.boiler_dhw_starts,5,9,1,65,2 -"Geo 5xx",boiler,173,dhw.workm,active time,time (>=0<=16777214),minutes,false,sensor.boiler_dhw_active_time,sensor.boiler_dhw_workm,5,9,1,67,2 +"Geo 5xx",boiler,173,dhw.chargepump,charge pump,boolean, ,false,binary_sensor.boiler_dhw_charge_pump,binary_sensor.boiler_dhw_chargepump,5,9,1,63,1 +"Geo 5xx",boiler,173,dhw.mixertemp,mixer temperature,uint16 (>=0<=3199),C,false,sensor.boiler_dhw_mixer_temperature,sensor.boiler_dhw_mixertemp,5,9,1/10,64,1 +"Geo 5xx",boiler,173,dhw.cylmiddletemp,cylinder middle temperature (TS3),uint16 (>=0<=3199),C,false,sensor.boiler_dhw_cylinder_middle_temperature_(TS3),sensor.boiler_dhw_cylmiddletemp,5,9,1/10,65,1 +"Geo 5xx",boiler,173,dhw.starts,starts,uint24 (>=0<=16777214), ,false,sensor.boiler_dhw_starts,sensor.boiler_dhw_starts,5,9,1,66,2 +"Geo 5xx",boiler,173,dhw.workm,active time,time (>=0<=16777214),minutes,false,sensor.boiler_dhw_active_time,sensor.boiler_dhw_workm,5,9,1,68,2 "Condens 5000i, Greenstar 8000/GC9800IW, GB192i*2",boiler,195,reset,reset,cmd [-\|maintenance\|error\|history\|message], ,true,sensor.boiler_reset,sensor.boiler_reset,5,0,1,0,1 "Condens 5000i, Greenstar 8000/GC9800IW, GB192i*2",boiler,195,heatingoff,force heating off,boolean, ,true,switch.boiler_force_heating_off,switch.boiler_heatingoff,5,0,1,1,1 "Condens 5000i, Greenstar 8000/GC9800IW, GB192i*2",boiler,195,heatingactive,heating active,boolean, ,false,binary_sensor.boiler_heating_active,binary_sensor.boiler_heatingactive,5,0,1,2,1 @@ -2740,9 +2761,9 @@ device name,device type,product id,shortname,fullname,type [options...] \| (min/ "Condens 5000i, Greenstar 8000/GC9800IW, GB192i*2",boiler,195,meterheat,meter heating,uint24 (>=0<=1677721),kWh,false,sensor.boiler_meter_heating,sensor.boiler_meterheat,5,0,1/10,95,2 "Condens 5000i, Greenstar 8000/GC9800IW, GB192i*2",boiler,195,dhw.meter,meter,uint24 (>=0<=1677721),kWh,false,sensor.boiler_dhw_meter,sensor.boiler_dhw_meter,5,9,1/10,2,2 "Condens 5000i, Greenstar 8000/GC9800IW, GB192i*2",boiler,195,gasmeterheat,gas meter heating,uint24 (>=0<=1677721),kWh,false,sensor.boiler_gas_meter_heating,sensor.boiler_gasmeterheat,5,0,1/10,266,2 -"Condens 5000i, Greenstar 8000/GC9800IW, GB192i*2",boiler,195,dhw.gasmeter,gas meter,uint24 (>=0<=1677721),kWh,false,sensor.boiler_dhw_gas_meter,sensor.boiler_dhw_gasmeter,5,9,1/10,69,2 +"Condens 5000i, Greenstar 8000/GC9800IW, GB192i*2",boiler,195,dhw.gasmeter,gas meter,uint24 (>=0<=1677721),kWh,false,sensor.boiler_dhw_gas_meter,sensor.boiler_dhw_gasmeter,5,9,1/10,70,2 "Condens 5000i, Greenstar 8000/GC9800IW, GB192i*2",boiler,195,nrgheat2,energy heating 2,uint24 (>=0<=1677721),kWh,false,sensor.boiler_energy_heating_2,sensor.boiler_nrgheat2,5,0,1/10,268,2 -"Condens 5000i, Greenstar 8000/GC9800IW, GB192i*2",boiler,195,dhw.nrg2,energy 2,uint24 (>=0<=1677721),kWh,false,sensor.boiler_dhw_energy_2,sensor.boiler_dhw_nrg2,5,9,1/10,71,2 +"Condens 5000i, Greenstar 8000/GC9800IW, GB192i*2",boiler,195,dhw.nrg2,energy 2,uint24 (>=0<=1677721),kWh,false,sensor.boiler_dhw_energy_2,sensor.boiler_dhw_nrg2,5,9,1/10,72,2 "Condens 5000i, Greenstar 8000/GC9800IW, GB192i*2",boiler,195,dhw.tapactivated,turn on/off,boolean, ,true,switch.boiler_dhw_turn_on/off,switch.boiler_dhw_tapactivated,5,9,1,28,1 "Condens 5000i, Greenstar 8000/GC9800IW, GB192i*2",boiler,195,dhw.settemp,set temperature,uint8 (>=0<=254),C,false,sensor.boiler_dhw_set_temperature,sensor.boiler_dhw_settemp,5,9,1,29,1 "Condens 5000i, Greenstar 8000/GC9800IW, GB192i*2",boiler,195,dhw.seltemp,selected temperature,uint8 (>=0<=254),C,true,number.boiler_dhw_selected_temperature,number.boiler_dhw_seltemp,5,9,1,30,1 @@ -2778,10 +2799,11 @@ device name,device type,product id,shortname,fullname,type [options...] \| (min/ "Condens 5000i, Greenstar 8000/GC9800IW, GB192i*2",boiler,195,dhw.tempok,temperature ok,boolean, ,false,binary_sensor.boiler_dhw_temperature_ok,binary_sensor.boiler_dhw_tempok,5,9,1,60,1 "Condens 5000i, Greenstar 8000/GC9800IW, GB192i*2",boiler,195,dhw.active,active,boolean, ,false,binary_sensor.boiler_dhw_active,binary_sensor.boiler_dhw_active,5,9,1,61,1 "Condens 5000i, Greenstar 8000/GC9800IW, GB192i*2",boiler,195,dhw.3wayvalve,3-way valve active,boolean, ,false,binary_sensor.boiler_dhw_3-way_valve_active,binary_sensor.boiler_dhw_3wayvalve,5,9,1,62,1 -"Condens 5000i, Greenstar 8000/GC9800IW, GB192i*2",boiler,195,dhw.mixertemp,mixer temperature,uint16 (>=0<=3199),C,false,sensor.boiler_dhw_mixer_temperature,sensor.boiler_dhw_mixertemp,5,9,1/10,63,1 -"Condens 5000i, Greenstar 8000/GC9800IW, GB192i*2",boiler,195,dhw.cylmiddletemp,cylinder middle temperature (TS3),uint16 (>=0<=3199),C,false,sensor.boiler_dhw_cylinder_middle_temperature_(TS3),sensor.boiler_dhw_cylmiddletemp,5,9,1/10,64,1 -"Condens 5000i, Greenstar 8000/GC9800IW, GB192i*2",boiler,195,dhw.starts,starts,uint24 (>=0<=16777214), ,false,sensor.boiler_dhw_starts,sensor.boiler_dhw_starts,5,9,1,65,2 -"Condens 5000i, Greenstar 8000/GC9800IW, GB192i*2",boiler,195,dhw.workm,active time,time (>=0<=16777214),minutes,false,sensor.boiler_dhw_active_time,sensor.boiler_dhw_workm,5,9,1,67,2 +"Condens 5000i, Greenstar 8000/GC9800IW, GB192i*2",boiler,195,dhw.chargepump,charge pump,boolean, ,false,binary_sensor.boiler_dhw_charge_pump,binary_sensor.boiler_dhw_chargepump,5,9,1,63,1 +"Condens 5000i, Greenstar 8000/GC9800IW, GB192i*2",boiler,195,dhw.mixertemp,mixer temperature,uint16 (>=0<=3199),C,false,sensor.boiler_dhw_mixer_temperature,sensor.boiler_dhw_mixertemp,5,9,1/10,64,1 +"Condens 5000i, Greenstar 8000/GC9800IW, GB192i*2",boiler,195,dhw.cylmiddletemp,cylinder middle temperature (TS3),uint16 (>=0<=3199),C,false,sensor.boiler_dhw_cylinder_middle_temperature_(TS3),sensor.boiler_dhw_cylmiddletemp,5,9,1/10,65,1 +"Condens 5000i, Greenstar 8000/GC9800IW, GB192i*2",boiler,195,dhw.starts,starts,uint24 (>=0<=16777214), ,false,sensor.boiler_dhw_starts,sensor.boiler_dhw_starts,5,9,1,66,2 +"Condens 5000i, Greenstar 8000/GC9800IW, GB192i*2",boiler,195,dhw.workm,active time,time (>=0<=16777214),minutes,false,sensor.boiler_dhw_active_time,sensor.boiler_dhw_workm,5,9,1,68,2 "Condens 5000i, Greenstar 8000/GC9800IW, GB192i*2",boiler,195,nompower,nominal Power,uint8 (>=0<=254),kW,true,number.boiler_nominal_Power,number.boiler_nompower,5,0,1,270,1 "Condens 5000i, Greenstar 8000/GC9800IW, GB192i*2",boiler,195,nrgtotal,total energy,uint24 (>=0<=167772),kWh,false,sensor.boiler_total_energy,sensor.boiler_nrgtotal,5,0,1/100,83,2 "Condens 5000i, Greenstar 8000/GC9800IW, GB192i*2",boiler,195,nrgheat,energy heating,uint24 (>=0<=10000000),kWh,true,number.boiler_energy_heating,number.boiler_nrgheat,5,0,1/100,85,2 @@ -2854,9 +2876,9 @@ device name,device type,product id,shortname,fullname,type [options...] \| (min/ "Logamax U122, Cerapur",boiler,203,meterheat,meter heating,uint24 (>=0<=1677721),kWh,false,sensor.boiler_meter_heating,sensor.boiler_meterheat,5,0,1/10,95,2 "Logamax U122, Cerapur",boiler,203,dhw.meter,meter,uint24 (>=0<=1677721),kWh,false,sensor.boiler_dhw_meter,sensor.boiler_dhw_meter,5,9,1/10,2,2 "Logamax U122, Cerapur",boiler,203,gasmeterheat,gas meter heating,uint24 (>=0<=1677721),kWh,false,sensor.boiler_gas_meter_heating,sensor.boiler_gasmeterheat,5,0,1/10,266,2 -"Logamax U122, Cerapur",boiler,203,dhw.gasmeter,gas meter,uint24 (>=0<=1677721),kWh,false,sensor.boiler_dhw_gas_meter,sensor.boiler_dhw_gasmeter,5,9,1/10,69,2 +"Logamax U122, Cerapur",boiler,203,dhw.gasmeter,gas meter,uint24 (>=0<=1677721),kWh,false,sensor.boiler_dhw_gas_meter,sensor.boiler_dhw_gasmeter,5,9,1/10,70,2 "Logamax U122, Cerapur",boiler,203,nrgheat2,energy heating 2,uint24 (>=0<=1677721),kWh,false,sensor.boiler_energy_heating_2,sensor.boiler_nrgheat2,5,0,1/10,268,2 -"Logamax U122, Cerapur",boiler,203,dhw.nrg2,energy 2,uint24 (>=0<=1677721),kWh,false,sensor.boiler_dhw_energy_2,sensor.boiler_dhw_nrg2,5,9,1/10,71,2 +"Logamax U122, Cerapur",boiler,203,dhw.nrg2,energy 2,uint24 (>=0<=1677721),kWh,false,sensor.boiler_dhw_energy_2,sensor.boiler_dhw_nrg2,5,9,1/10,72,2 "Logamax U122, Cerapur",boiler,203,dhw.tapactivated,turn on/off,boolean, ,true,switch.boiler_dhw_turn_on/off,switch.boiler_dhw_tapactivated,5,9,1,28,1 "Logamax U122, Cerapur",boiler,203,dhw.settemp,set temperature,uint8 (>=0<=254),C,false,sensor.boiler_dhw_set_temperature,sensor.boiler_dhw_settemp,5,9,1,29,1 "Logamax U122, Cerapur",boiler,203,dhw.seltemp,selected temperature,uint8 (>=0<=254),C,true,number.boiler_dhw_selected_temperature,number.boiler_dhw_seltemp,5,9,1,30,1 @@ -2892,10 +2914,11 @@ device name,device type,product id,shortname,fullname,type [options...] \| (min/ "Logamax U122, Cerapur",boiler,203,dhw.tempok,temperature ok,boolean, ,false,binary_sensor.boiler_dhw_temperature_ok,binary_sensor.boiler_dhw_tempok,5,9,1,60,1 "Logamax U122, Cerapur",boiler,203,dhw.active,active,boolean, ,false,binary_sensor.boiler_dhw_active,binary_sensor.boiler_dhw_active,5,9,1,61,1 "Logamax U122, Cerapur",boiler,203,dhw.3wayvalve,3-way valve active,boolean, ,false,binary_sensor.boiler_dhw_3-way_valve_active,binary_sensor.boiler_dhw_3wayvalve,5,9,1,62,1 -"Logamax U122, Cerapur",boiler,203,dhw.mixertemp,mixer temperature,uint16 (>=0<=3199),C,false,sensor.boiler_dhw_mixer_temperature,sensor.boiler_dhw_mixertemp,5,9,1/10,63,1 -"Logamax U122, Cerapur",boiler,203,dhw.cylmiddletemp,cylinder middle temperature (TS3),uint16 (>=0<=3199),C,false,sensor.boiler_dhw_cylinder_middle_temperature_(TS3),sensor.boiler_dhw_cylmiddletemp,5,9,1/10,64,1 -"Logamax U122, Cerapur",boiler,203,dhw.starts,starts,uint24 (>=0<=16777214), ,false,sensor.boiler_dhw_starts,sensor.boiler_dhw_starts,5,9,1,65,2 -"Logamax U122, Cerapur",boiler,203,dhw.workm,active time,time (>=0<=16777214),minutes,false,sensor.boiler_dhw_active_time,sensor.boiler_dhw_workm,5,9,1,67,2 +"Logamax U122, Cerapur",boiler,203,dhw.chargepump,charge pump,boolean, ,false,binary_sensor.boiler_dhw_charge_pump,binary_sensor.boiler_dhw_chargepump,5,9,1,63,1 +"Logamax U122, Cerapur",boiler,203,dhw.mixertemp,mixer temperature,uint16 (>=0<=3199),C,false,sensor.boiler_dhw_mixer_temperature,sensor.boiler_dhw_mixertemp,5,9,1/10,64,1 +"Logamax U122, Cerapur",boiler,203,dhw.cylmiddletemp,cylinder middle temperature (TS3),uint16 (>=0<=3199),C,false,sensor.boiler_dhw_cylinder_middle_temperature_(TS3),sensor.boiler_dhw_cylmiddletemp,5,9,1/10,65,1 +"Logamax U122, Cerapur",boiler,203,dhw.starts,starts,uint24 (>=0<=16777214), ,false,sensor.boiler_dhw_starts,sensor.boiler_dhw_starts,5,9,1,66,2 +"Logamax U122, Cerapur",boiler,203,dhw.workm,active time,time (>=0<=16777214),minutes,false,sensor.boiler_dhw_active_time,sensor.boiler_dhw_workm,5,9,1,68,2 "Logamax U122, Cerapur",boiler,203,nompower,nominal Power,uint8 (>=0<=254),kW,true,number.boiler_nominal_Power,number.boiler_nompower,5,0,1,270,1 "Logamax U122, Cerapur",boiler,203,nrgtotal,total energy,uint24 (>=0<=167772),kWh,false,sensor.boiler_total_energy,sensor.boiler_nrgtotal,5,0,1/100,83,2 "Logamax U122, Cerapur",boiler,203,nrgheat,energy heating,uint24 (>=0<=10000000),kWh,true,number.boiler_energy_heating,number.boiler_nrgheat,5,0,1/100,85,2 @@ -2968,9 +2991,9 @@ device name,device type,product id,shortname,fullname,type [options...] \| (min/ "Ecomline Excellent",boiler,206,meterheat,meter heating,uint24 (>=0<=1677721),kWh,false,sensor.boiler_meter_heating,sensor.boiler_meterheat,5,0,1/10,95,2 "Ecomline Excellent",boiler,206,dhw.meter,meter,uint24 (>=0<=1677721),kWh,false,sensor.boiler_dhw_meter,sensor.boiler_dhw_meter,5,9,1/10,2,2 "Ecomline Excellent",boiler,206,gasmeterheat,gas meter heating,uint24 (>=0<=1677721),kWh,false,sensor.boiler_gas_meter_heating,sensor.boiler_gasmeterheat,5,0,1/10,266,2 -"Ecomline Excellent",boiler,206,dhw.gasmeter,gas meter,uint24 (>=0<=1677721),kWh,false,sensor.boiler_dhw_gas_meter,sensor.boiler_dhw_gasmeter,5,9,1/10,69,2 +"Ecomline Excellent",boiler,206,dhw.gasmeter,gas meter,uint24 (>=0<=1677721),kWh,false,sensor.boiler_dhw_gas_meter,sensor.boiler_dhw_gasmeter,5,9,1/10,70,2 "Ecomline Excellent",boiler,206,nrgheat2,energy heating 2,uint24 (>=0<=1677721),kWh,false,sensor.boiler_energy_heating_2,sensor.boiler_nrgheat2,5,0,1/10,268,2 -"Ecomline Excellent",boiler,206,dhw.nrg2,energy 2,uint24 (>=0<=1677721),kWh,false,sensor.boiler_dhw_energy_2,sensor.boiler_dhw_nrg2,5,9,1/10,71,2 +"Ecomline Excellent",boiler,206,dhw.nrg2,energy 2,uint24 (>=0<=1677721),kWh,false,sensor.boiler_dhw_energy_2,sensor.boiler_dhw_nrg2,5,9,1/10,72,2 "Ecomline Excellent",boiler,206,dhw.tapactivated,turn on/off,boolean, ,true,switch.boiler_dhw_turn_on/off,switch.boiler_dhw_tapactivated,5,9,1,28,1 "Ecomline Excellent",boiler,206,dhw.settemp,set temperature,uint8 (>=0<=254),C,false,sensor.boiler_dhw_set_temperature,sensor.boiler_dhw_settemp,5,9,1,29,1 "Ecomline Excellent",boiler,206,dhw.seltemp,selected temperature,uint8 (>=0<=254),C,true,number.boiler_dhw_selected_temperature,number.boiler_dhw_seltemp,5,9,1,30,1 @@ -3006,10 +3029,11 @@ device name,device type,product id,shortname,fullname,type [options...] \| (min/ "Ecomline Excellent",boiler,206,dhw.tempok,temperature ok,boolean, ,false,binary_sensor.boiler_dhw_temperature_ok,binary_sensor.boiler_dhw_tempok,5,9,1,60,1 "Ecomline Excellent",boiler,206,dhw.active,active,boolean, ,false,binary_sensor.boiler_dhw_active,binary_sensor.boiler_dhw_active,5,9,1,61,1 "Ecomline Excellent",boiler,206,dhw.3wayvalve,3-way valve active,boolean, ,false,binary_sensor.boiler_dhw_3-way_valve_active,binary_sensor.boiler_dhw_3wayvalve,5,9,1,62,1 -"Ecomline Excellent",boiler,206,dhw.mixertemp,mixer temperature,uint16 (>=0<=3199),C,false,sensor.boiler_dhw_mixer_temperature,sensor.boiler_dhw_mixertemp,5,9,1/10,63,1 -"Ecomline Excellent",boiler,206,dhw.cylmiddletemp,cylinder middle temperature (TS3),uint16 (>=0<=3199),C,false,sensor.boiler_dhw_cylinder_middle_temperature_(TS3),sensor.boiler_dhw_cylmiddletemp,5,9,1/10,64,1 -"Ecomline Excellent",boiler,206,dhw.starts,starts,uint24 (>=0<=16777214), ,false,sensor.boiler_dhw_starts,sensor.boiler_dhw_starts,5,9,1,65,2 -"Ecomline Excellent",boiler,206,dhw.workm,active time,time (>=0<=16777214),minutes,false,sensor.boiler_dhw_active_time,sensor.boiler_dhw_workm,5,9,1,67,2 +"Ecomline Excellent",boiler,206,dhw.chargepump,charge pump,boolean, ,false,binary_sensor.boiler_dhw_charge_pump,binary_sensor.boiler_dhw_chargepump,5,9,1,63,1 +"Ecomline Excellent",boiler,206,dhw.mixertemp,mixer temperature,uint16 (>=0<=3199),C,false,sensor.boiler_dhw_mixer_temperature,sensor.boiler_dhw_mixertemp,5,9,1/10,64,1 +"Ecomline Excellent",boiler,206,dhw.cylmiddletemp,cylinder middle temperature (TS3),uint16 (>=0<=3199),C,false,sensor.boiler_dhw_cylinder_middle_temperature_(TS3),sensor.boiler_dhw_cylmiddletemp,5,9,1/10,65,1 +"Ecomline Excellent",boiler,206,dhw.starts,starts,uint24 (>=0<=16777214), ,false,sensor.boiler_dhw_starts,sensor.boiler_dhw_starts,5,9,1,66,2 +"Ecomline Excellent",boiler,206,dhw.workm,active time,time (>=0<=16777214),minutes,false,sensor.boiler_dhw_active_time,sensor.boiler_dhw_workm,5,9,1,68,2 "Ecomline Excellent",boiler,206,nompower,nominal Power,uint8 (>=0<=254),kW,true,number.boiler_nominal_Power,number.boiler_nompower,5,0,1,270,1 "Ecomline Excellent",boiler,206,nrgtotal,total energy,uint24 (>=0<=167772),kWh,false,sensor.boiler_total_energy,sensor.boiler_nrgtotal,5,0,1/100,83,2 "Ecomline Excellent",boiler,206,nrgheat,energy heating,uint24 (>=0<=10000000),kWh,true,number.boiler_energy_heating,number.boiler_nrgheat,5,0,1/100,85,2 @@ -3082,9 +3106,9 @@ device name,device type,product id,shortname,fullname,type [options...] \| (min/ "Logamax Plus, GB192, Condens GC9000, Greenstar ErP",boiler,208,meterheat,meter heating,uint24 (>=0<=1677721),kWh,false,sensor.boiler_meter_heating,sensor.boiler_meterheat,5,0,1/10,95,2 "Logamax Plus, GB192, Condens GC9000, Greenstar ErP",boiler,208,dhw.meter,meter,uint24 (>=0<=1677721),kWh,false,sensor.boiler_dhw_meter,sensor.boiler_dhw_meter,5,9,1/10,2,2 "Logamax Plus, GB192, Condens GC9000, Greenstar ErP",boiler,208,gasmeterheat,gas meter heating,uint24 (>=0<=1677721),kWh,false,sensor.boiler_gas_meter_heating,sensor.boiler_gasmeterheat,5,0,1/10,266,2 -"Logamax Plus, GB192, Condens GC9000, Greenstar ErP",boiler,208,dhw.gasmeter,gas meter,uint24 (>=0<=1677721),kWh,false,sensor.boiler_dhw_gas_meter,sensor.boiler_dhw_gasmeter,5,9,1/10,69,2 +"Logamax Plus, GB192, Condens GC9000, Greenstar ErP",boiler,208,dhw.gasmeter,gas meter,uint24 (>=0<=1677721),kWh,false,sensor.boiler_dhw_gas_meter,sensor.boiler_dhw_gasmeter,5,9,1/10,70,2 "Logamax Plus, GB192, Condens GC9000, Greenstar ErP",boiler,208,nrgheat2,energy heating 2,uint24 (>=0<=1677721),kWh,false,sensor.boiler_energy_heating_2,sensor.boiler_nrgheat2,5,0,1/10,268,2 -"Logamax Plus, GB192, Condens GC9000, Greenstar ErP",boiler,208,dhw.nrg2,energy 2,uint24 (>=0<=1677721),kWh,false,sensor.boiler_dhw_energy_2,sensor.boiler_dhw_nrg2,5,9,1/10,71,2 +"Logamax Plus, GB192, Condens GC9000, Greenstar ErP",boiler,208,dhw.nrg2,energy 2,uint24 (>=0<=1677721),kWh,false,sensor.boiler_dhw_energy_2,sensor.boiler_dhw_nrg2,5,9,1/10,72,2 "Logamax Plus, GB192, Condens GC9000, Greenstar ErP",boiler,208,dhw.tapactivated,turn on/off,boolean, ,true,switch.boiler_dhw_turn_on/off,switch.boiler_dhw_tapactivated,5,9,1,28,1 "Logamax Plus, GB192, Condens GC9000, Greenstar ErP",boiler,208,dhw.settemp,set temperature,uint8 (>=0<=254),C,false,sensor.boiler_dhw_set_temperature,sensor.boiler_dhw_settemp,5,9,1,29,1 "Logamax Plus, GB192, Condens GC9000, Greenstar ErP",boiler,208,dhw.seltemp,selected temperature,uint8 (>=0<=254),C,true,number.boiler_dhw_selected_temperature,number.boiler_dhw_seltemp,5,9,1,30,1 @@ -3120,10 +3144,11 @@ device name,device type,product id,shortname,fullname,type [options...] \| (min/ "Logamax Plus, GB192, Condens GC9000, Greenstar ErP",boiler,208,dhw.tempok,temperature ok,boolean, ,false,binary_sensor.boiler_dhw_temperature_ok,binary_sensor.boiler_dhw_tempok,5,9,1,60,1 "Logamax Plus, GB192, Condens GC9000, Greenstar ErP",boiler,208,dhw.active,active,boolean, ,false,binary_sensor.boiler_dhw_active,binary_sensor.boiler_dhw_active,5,9,1,61,1 "Logamax Plus, GB192, Condens GC9000, Greenstar ErP",boiler,208,dhw.3wayvalve,3-way valve active,boolean, ,false,binary_sensor.boiler_dhw_3-way_valve_active,binary_sensor.boiler_dhw_3wayvalve,5,9,1,62,1 -"Logamax Plus, GB192, Condens GC9000, Greenstar ErP",boiler,208,dhw.mixertemp,mixer temperature,uint16 (>=0<=3199),C,false,sensor.boiler_dhw_mixer_temperature,sensor.boiler_dhw_mixertemp,5,9,1/10,63,1 -"Logamax Plus, GB192, Condens GC9000, Greenstar ErP",boiler,208,dhw.cylmiddletemp,cylinder middle temperature (TS3),uint16 (>=0<=3199),C,false,sensor.boiler_dhw_cylinder_middle_temperature_(TS3),sensor.boiler_dhw_cylmiddletemp,5,9,1/10,64,1 -"Logamax Plus, GB192, Condens GC9000, Greenstar ErP",boiler,208,dhw.starts,starts,uint24 (>=0<=16777214), ,false,sensor.boiler_dhw_starts,sensor.boiler_dhw_starts,5,9,1,65,2 -"Logamax Plus, GB192, Condens GC9000, Greenstar ErP",boiler,208,dhw.workm,active time,time (>=0<=16777214),minutes,false,sensor.boiler_dhw_active_time,sensor.boiler_dhw_workm,5,9,1,67,2 +"Logamax Plus, GB192, Condens GC9000, Greenstar ErP",boiler,208,dhw.chargepump,charge pump,boolean, ,false,binary_sensor.boiler_dhw_charge_pump,binary_sensor.boiler_dhw_chargepump,5,9,1,63,1 +"Logamax Plus, GB192, Condens GC9000, Greenstar ErP",boiler,208,dhw.mixertemp,mixer temperature,uint16 (>=0<=3199),C,false,sensor.boiler_dhw_mixer_temperature,sensor.boiler_dhw_mixertemp,5,9,1/10,64,1 +"Logamax Plus, GB192, Condens GC9000, Greenstar ErP",boiler,208,dhw.cylmiddletemp,cylinder middle temperature (TS3),uint16 (>=0<=3199),C,false,sensor.boiler_dhw_cylinder_middle_temperature_(TS3),sensor.boiler_dhw_cylmiddletemp,5,9,1/10,65,1 +"Logamax Plus, GB192, Condens GC9000, Greenstar ErP",boiler,208,dhw.starts,starts,uint24 (>=0<=16777214), ,false,sensor.boiler_dhw_starts,sensor.boiler_dhw_starts,5,9,1,66,2 +"Logamax Plus, GB192, Condens GC9000, Greenstar ErP",boiler,208,dhw.workm,active time,time (>=0<=16777214),minutes,false,sensor.boiler_dhw_active_time,sensor.boiler_dhw_workm,5,9,1,68,2 "Logamax Plus, GB192, Condens GC9000, Greenstar ErP",boiler,208,nompower,nominal Power,uint8 (>=0<=254),kW,true,number.boiler_nominal_Power,number.boiler_nompower,5,0,1,270,1 "Logamax Plus, GB192, Condens GC9000, Greenstar ErP",boiler,208,nrgtotal,total energy,uint24 (>=0<=167772),kWh,false,sensor.boiler_total_energy,sensor.boiler_nrgtotal,5,0,1/100,83,2 "Logamax Plus, GB192, Condens GC9000, Greenstar ErP",boiler,208,nrgheat,energy heating,uint24 (>=0<=10000000),kWh,true,number.boiler_energy_heating,number.boiler_nrgheat,5,0,1/100,85,2 @@ -3196,9 +3221,9 @@ device name,device type,product id,shortname,fullname,type [options...] \| (min/ "Cascade MC400",boiler,210,meterheat,meter heating,uint24 (>=0<=1677721),kWh,false,sensor.boiler_meter_heating,sensor.boiler_meterheat,5,0,1/10,95,2 "Cascade MC400",boiler,210,dhw.meter,meter,uint24 (>=0<=1677721),kWh,false,sensor.boiler_dhw_meter,sensor.boiler_dhw_meter,5,9,1/10,2,2 "Cascade MC400",boiler,210,gasmeterheat,gas meter heating,uint24 (>=0<=1677721),kWh,false,sensor.boiler_gas_meter_heating,sensor.boiler_gasmeterheat,5,0,1/10,266,2 -"Cascade MC400",boiler,210,dhw.gasmeter,gas meter,uint24 (>=0<=1677721),kWh,false,sensor.boiler_dhw_gas_meter,sensor.boiler_dhw_gasmeter,5,9,1/10,69,2 +"Cascade MC400",boiler,210,dhw.gasmeter,gas meter,uint24 (>=0<=1677721),kWh,false,sensor.boiler_dhw_gas_meter,sensor.boiler_dhw_gasmeter,5,9,1/10,70,2 "Cascade MC400",boiler,210,nrgheat2,energy heating 2,uint24 (>=0<=1677721),kWh,false,sensor.boiler_energy_heating_2,sensor.boiler_nrgheat2,5,0,1/10,268,2 -"Cascade MC400",boiler,210,dhw.nrg2,energy 2,uint24 (>=0<=1677721),kWh,false,sensor.boiler_dhw_energy_2,sensor.boiler_dhw_nrg2,5,9,1/10,71,2 +"Cascade MC400",boiler,210,dhw.nrg2,energy 2,uint24 (>=0<=1677721),kWh,false,sensor.boiler_dhw_energy_2,sensor.boiler_dhw_nrg2,5,9,1/10,72,2 "Cascade MC400",boiler,210,dhw.tapactivated,turn on/off,boolean, ,true,switch.boiler_dhw_turn_on/off,switch.boiler_dhw_tapactivated,5,9,1,28,1 "Cascade MC400",boiler,210,dhw.settemp,set temperature,uint8 (>=0<=254),C,false,sensor.boiler_dhw_set_temperature,sensor.boiler_dhw_settemp,5,9,1,29,1 "Cascade MC400",boiler,210,dhw.seltemp,selected temperature,uint8 (>=0<=254),C,true,number.boiler_dhw_selected_temperature,number.boiler_dhw_seltemp,5,9,1,30,1 @@ -3234,10 +3259,11 @@ device name,device type,product id,shortname,fullname,type [options...] \| (min/ "Cascade MC400",boiler,210,dhw.tempok,temperature ok,boolean, ,false,binary_sensor.boiler_dhw_temperature_ok,binary_sensor.boiler_dhw_tempok,5,9,1,60,1 "Cascade MC400",boiler,210,dhw.active,active,boolean, ,false,binary_sensor.boiler_dhw_active,binary_sensor.boiler_dhw_active,5,9,1,61,1 "Cascade MC400",boiler,210,dhw.3wayvalve,3-way valve active,boolean, ,false,binary_sensor.boiler_dhw_3-way_valve_active,binary_sensor.boiler_dhw_3wayvalve,5,9,1,62,1 -"Cascade MC400",boiler,210,dhw.mixertemp,mixer temperature,uint16 (>=0<=3199),C,false,sensor.boiler_dhw_mixer_temperature,sensor.boiler_dhw_mixertemp,5,9,1/10,63,1 -"Cascade MC400",boiler,210,dhw.cylmiddletemp,cylinder middle temperature (TS3),uint16 (>=0<=3199),C,false,sensor.boiler_dhw_cylinder_middle_temperature_(TS3),sensor.boiler_dhw_cylmiddletemp,5,9,1/10,64,1 -"Cascade MC400",boiler,210,dhw.starts,starts,uint24 (>=0<=16777214), ,false,sensor.boiler_dhw_starts,sensor.boiler_dhw_starts,5,9,1,65,2 -"Cascade MC400",boiler,210,dhw.workm,active time,time (>=0<=16777214),minutes,false,sensor.boiler_dhw_active_time,sensor.boiler_dhw_workm,5,9,1,67,2 +"Cascade MC400",boiler,210,dhw.chargepump,charge pump,boolean, ,false,binary_sensor.boiler_dhw_charge_pump,binary_sensor.boiler_dhw_chargepump,5,9,1,63,1 +"Cascade MC400",boiler,210,dhw.mixertemp,mixer temperature,uint16 (>=0<=3199),C,false,sensor.boiler_dhw_mixer_temperature,sensor.boiler_dhw_mixertemp,5,9,1/10,64,1 +"Cascade MC400",boiler,210,dhw.cylmiddletemp,cylinder middle temperature (TS3),uint16 (>=0<=3199),C,false,sensor.boiler_dhw_cylinder_middle_temperature_(TS3),sensor.boiler_dhw_cylmiddletemp,5,9,1/10,65,1 +"Cascade MC400",boiler,210,dhw.starts,starts,uint24 (>=0<=16777214), ,false,sensor.boiler_dhw_starts,sensor.boiler_dhw_starts,5,9,1,66,2 +"Cascade MC400",boiler,210,dhw.workm,active time,time (>=0<=16777214),minutes,false,sensor.boiler_dhw_active_time,sensor.boiler_dhw_workm,5,9,1,68,2 "Cascade MC400",boiler,210,nompower,nominal Power,uint8 (>=0<=254),kW,true,number.boiler_nominal_Power,number.boiler_nompower,5,0,1,270,1 "Cascade MC400",boiler,210,nrgtotal,total energy,uint24 (>=0<=167772),kWh,false,sensor.boiler_total_energy,sensor.boiler_nrgtotal,5,0,1/100,83,2 "Cascade MC400",boiler,210,nrgheat,energy heating,uint24 (>=0<=10000000),kWh,true,number.boiler_energy_heating,number.boiler_nrgheat,5,0,1/100,85,2 @@ -3310,9 +3336,9 @@ device name,device type,product id,shortname,fullname,type [options...] \| (min/ "EasyControl Adapter",boiler,211,meterheat,meter heating,uint24 (>=0<=1677721),kWh,false,sensor.boiler_meter_heating,sensor.boiler_meterheat,5,0,1/10,95,2 "EasyControl Adapter",boiler,211,dhw.meter,meter,uint24 (>=0<=1677721),kWh,false,sensor.boiler_dhw_meter,sensor.boiler_dhw_meter,5,9,1/10,2,2 "EasyControl Adapter",boiler,211,gasmeterheat,gas meter heating,uint24 (>=0<=1677721),kWh,false,sensor.boiler_gas_meter_heating,sensor.boiler_gasmeterheat,5,0,1/10,266,2 -"EasyControl Adapter",boiler,211,dhw.gasmeter,gas meter,uint24 (>=0<=1677721),kWh,false,sensor.boiler_dhw_gas_meter,sensor.boiler_dhw_gasmeter,5,9,1/10,69,2 +"EasyControl Adapter",boiler,211,dhw.gasmeter,gas meter,uint24 (>=0<=1677721),kWh,false,sensor.boiler_dhw_gas_meter,sensor.boiler_dhw_gasmeter,5,9,1/10,70,2 "EasyControl Adapter",boiler,211,nrgheat2,energy heating 2,uint24 (>=0<=1677721),kWh,false,sensor.boiler_energy_heating_2,sensor.boiler_nrgheat2,5,0,1/10,268,2 -"EasyControl Adapter",boiler,211,dhw.nrg2,energy 2,uint24 (>=0<=1677721),kWh,false,sensor.boiler_dhw_energy_2,sensor.boiler_dhw_nrg2,5,9,1/10,71,2 +"EasyControl Adapter",boiler,211,dhw.nrg2,energy 2,uint24 (>=0<=1677721),kWh,false,sensor.boiler_dhw_energy_2,sensor.boiler_dhw_nrg2,5,9,1/10,72,2 "EasyControl Adapter",boiler,211,dhw.tapactivated,turn on/off,boolean, ,true,switch.boiler_dhw_turn_on/off,switch.boiler_dhw_tapactivated,5,9,1,28,1 "EasyControl Adapter",boiler,211,dhw.settemp,set temperature,uint8 (>=0<=254),C,false,sensor.boiler_dhw_set_temperature,sensor.boiler_dhw_settemp,5,9,1,29,1 "EasyControl Adapter",boiler,211,dhw.seltemp,selected temperature,uint8 (>=0<=254),C,true,number.boiler_dhw_selected_temperature,number.boiler_dhw_seltemp,5,9,1,30,1 @@ -3348,17 +3374,18 @@ device name,device type,product id,shortname,fullname,type [options...] \| (min/ "EasyControl Adapter",boiler,211,dhw.tempok,temperature ok,boolean, ,false,binary_sensor.boiler_dhw_temperature_ok,binary_sensor.boiler_dhw_tempok,5,9,1,60,1 "EasyControl Adapter",boiler,211,dhw.active,active,boolean, ,false,binary_sensor.boiler_dhw_active,binary_sensor.boiler_dhw_active,5,9,1,61,1 "EasyControl Adapter",boiler,211,dhw.3wayvalve,3-way valve active,boolean, ,false,binary_sensor.boiler_dhw_3-way_valve_active,binary_sensor.boiler_dhw_3wayvalve,5,9,1,62,1 -"EasyControl Adapter",boiler,211,dhw.mixertemp,mixer temperature,uint16 (>=0<=3199),C,false,sensor.boiler_dhw_mixer_temperature,sensor.boiler_dhw_mixertemp,5,9,1/10,63,1 -"EasyControl Adapter",boiler,211,dhw.cylmiddletemp,cylinder middle temperature (TS3),uint16 (>=0<=3199),C,false,sensor.boiler_dhw_cylinder_middle_temperature_(TS3),sensor.boiler_dhw_cylmiddletemp,5,9,1/10,64,1 -"EasyControl Adapter",boiler,211,dhw.starts,starts,uint24 (>=0<=16777214), ,false,sensor.boiler_dhw_starts,sensor.boiler_dhw_starts,5,9,1,65,2 -"EasyControl Adapter",boiler,211,dhw.workm,active time,time (>=0<=16777214),minutes,false,sensor.boiler_dhw_active_time,sensor.boiler_dhw_workm,5,9,1,67,2 +"EasyControl Adapter",boiler,211,dhw.chargepump,charge pump,boolean, ,false,binary_sensor.boiler_dhw_charge_pump,binary_sensor.boiler_dhw_chargepump,5,9,1,63,1 +"EasyControl Adapter",boiler,211,dhw.mixertemp,mixer temperature,uint16 (>=0<=3199),C,false,sensor.boiler_dhw_mixer_temperature,sensor.boiler_dhw_mixertemp,5,9,1/10,64,1 +"EasyControl Adapter",boiler,211,dhw.cylmiddletemp,cylinder middle temperature (TS3),uint16 (>=0<=3199),C,false,sensor.boiler_dhw_cylinder_middle_temperature_(TS3),sensor.boiler_dhw_cylmiddletemp,5,9,1/10,65,1 +"EasyControl Adapter",boiler,211,dhw.starts,starts,uint24 (>=0<=16777214), ,false,sensor.boiler_dhw_starts,sensor.boiler_dhw_starts,5,9,1,66,2 +"EasyControl Adapter",boiler,211,dhw.workm,active time,time (>=0<=16777214),minutes,false,sensor.boiler_dhw_active_time,sensor.boiler_dhw_workm,5,9,1,68,2 "EasyControl Adapter",boiler,211,nompower,nominal Power,uint8 (>=0<=254),kW,true,number.boiler_nominal_Power,number.boiler_nompower,5,0,1,270,1 "EasyControl Adapter",boiler,211,nrgtotal,total energy,uint24 (>=0<=167772),kWh,false,sensor.boiler_total_energy,sensor.boiler_nrgtotal,5,0,1/100,83,2 "EasyControl Adapter",boiler,211,nrgheat,energy heating,uint24 (>=0<=10000000),kWh,true,number.boiler_energy_heating,number.boiler_nrgheat,5,0,1/100,85,2 "EasyControl Adapter",boiler,211,dhw.nrg,energy,uint24 (>=0<=10000000),kWh,true,number.boiler_dhw_energy,number.boiler_dhw_nrg,5,9,1/100,0,2 "Greenstar HIU, Logamax kompakt WS170",boiler,219,netflowtemp,heat network flow temp,uint16 (>=0<=3199),C,false,sensor.boiler_heat_network_flow_temp,sensor.boiler_netflowtemp,5,0,1/10,271,1 "Greenstar HIU, Logamax kompakt WS170",boiler,219,heatvalve,heating valve,uint8 (>=0<=100),%,false,sensor.boiler_heating_valve,sensor.boiler_heatvalve,5,0,1,272,1 -"Greenstar HIU, Logamax kompakt WS170",boiler,219,dhw.dhwvalve,valve,uint8 (>=0<=100),%,false,sensor.boiler_dhw_valve,sensor.boiler_dhw_dhwvalve,5,9,1,73,1 +"Greenstar HIU, Logamax kompakt WS170",boiler,219,dhw.dhwvalve,valve,uint8 (>=0<=100),%,false,sensor.boiler_dhw_valve,sensor.boiler_dhw_dhwvalve,5,9,1,74,1 "Greenstar HIU, Logamax kompakt WS170",boiler,219,keepwarmtemp,keep warm temperature,uint8 (>=0<=254),C,true,number.boiler_keep_warm_temperature,number.boiler_keepwarmtemp,5,0,1,273,1 "Greenstar HIU, Logamax kompakt WS170",boiler,219,setreturntemp,set temp return,uint8 (>=0<=254),C,true,number.boiler_set_temp_return,number.boiler_setreturntemp,5,0,1,274,1 "Greenstar HIU, Logamax kompakt WS170",boiler,219,heating,heating,boolean, ,false,binary_sensor.boiler_heating,binary_sensor.boiler_heating,5,0,1,275,1 @@ -3408,9 +3435,9 @@ device name,device type,product id,shortname,fullname,type [options...] \| (min/ "Greenstar HIU, Logamax kompakt WS170",boiler,219,meterheat,meter heating,uint24 (>=0<=1677721),kWh,false,sensor.boiler_meter_heating,sensor.boiler_meterheat,5,0,1/10,95,2 "Greenstar HIU, Logamax kompakt WS170",boiler,219,dhw.meter,meter,uint24 (>=0<=1677721),kWh,false,sensor.boiler_dhw_meter,sensor.boiler_dhw_meter,5,9,1/10,2,2 "Greenstar HIU, Logamax kompakt WS170",boiler,219,gasmeterheat,gas meter heating,uint24 (>=0<=1677721),kWh,false,sensor.boiler_gas_meter_heating,sensor.boiler_gasmeterheat,5,0,1/10,266,2 -"Greenstar HIU, Logamax kompakt WS170",boiler,219,dhw.gasmeter,gas meter,uint24 (>=0<=1677721),kWh,false,sensor.boiler_dhw_gas_meter,sensor.boiler_dhw_gasmeter,5,9,1/10,69,2 +"Greenstar HIU, Logamax kompakt WS170",boiler,219,dhw.gasmeter,gas meter,uint24 (>=0<=1677721),kWh,false,sensor.boiler_dhw_gas_meter,sensor.boiler_dhw_gasmeter,5,9,1/10,70,2 "Greenstar HIU, Logamax kompakt WS170",boiler,219,nrgheat2,energy heating 2,uint24 (>=0<=1677721),kWh,false,sensor.boiler_energy_heating_2,sensor.boiler_nrgheat2,5,0,1/10,268,2 -"Greenstar HIU, Logamax kompakt WS170",boiler,219,dhw.nrg2,energy 2,uint24 (>=0<=1677721),kWh,false,sensor.boiler_dhw_energy_2,sensor.boiler_dhw_nrg2,5,9,1/10,71,2 +"Greenstar HIU, Logamax kompakt WS170",boiler,219,dhw.nrg2,energy 2,uint24 (>=0<=1677721),kWh,false,sensor.boiler_dhw_energy_2,sensor.boiler_dhw_nrg2,5,9,1/10,72,2 "Greenstar HIU, Logamax kompakt WS170",boiler,219,dhw.tapactivated,turn on/off,boolean, ,true,switch.boiler_dhw_turn_on/off,switch.boiler_dhw_tapactivated,5,9,1,28,1 "Greenstar HIU, Logamax kompakt WS170",boiler,219,dhw.settemp,set temperature,uint8 (>=0<=254),C,false,sensor.boiler_dhw_set_temperature,sensor.boiler_dhw_settemp,5,9,1,29,1 "Greenstar HIU, Logamax kompakt WS170",boiler,219,dhw.seltemp,selected temperature,uint8 (>=0<=254),C,true,number.boiler_dhw_selected_temperature,number.boiler_dhw_seltemp,5,9,1,30,1 @@ -3446,10 +3473,11 @@ device name,device type,product id,shortname,fullname,type [options...] \| (min/ "Greenstar HIU, Logamax kompakt WS170",boiler,219,dhw.tempok,temperature ok,boolean, ,false,binary_sensor.boiler_dhw_temperature_ok,binary_sensor.boiler_dhw_tempok,5,9,1,60,1 "Greenstar HIU, Logamax kompakt WS170",boiler,219,dhw.active,active,boolean, ,false,binary_sensor.boiler_dhw_active,binary_sensor.boiler_dhw_active,5,9,1,61,1 "Greenstar HIU, Logamax kompakt WS170",boiler,219,dhw.3wayvalve,3-way valve active,boolean, ,false,binary_sensor.boiler_dhw_3-way_valve_active,binary_sensor.boiler_dhw_3wayvalve,5,9,1,62,1 -"Greenstar HIU, Logamax kompakt WS170",boiler,219,dhw.mixertemp,mixer temperature,uint16 (>=0<=3199),C,false,sensor.boiler_dhw_mixer_temperature,sensor.boiler_dhw_mixertemp,5,9,1/10,63,1 -"Greenstar HIU, Logamax kompakt WS170",boiler,219,dhw.cylmiddletemp,cylinder middle temperature (TS3),uint16 (>=0<=3199),C,false,sensor.boiler_dhw_cylinder_middle_temperature_(TS3),sensor.boiler_dhw_cylmiddletemp,5,9,1/10,64,1 -"Greenstar HIU, Logamax kompakt WS170",boiler,219,dhw.starts,starts,uint24 (>=0<=16777214), ,false,sensor.boiler_dhw_starts,sensor.boiler_dhw_starts,5,9,1,65,2 -"Greenstar HIU, Logamax kompakt WS170",boiler,219,dhw.workm,active time,time (>=0<=16777214),minutes,false,sensor.boiler_dhw_active_time,sensor.boiler_dhw_workm,5,9,1,67,2 +"Greenstar HIU, Logamax kompakt WS170",boiler,219,dhw.chargepump,charge pump,boolean, ,false,binary_sensor.boiler_dhw_charge_pump,binary_sensor.boiler_dhw_chargepump,5,9,1,63,1 +"Greenstar HIU, Logamax kompakt WS170",boiler,219,dhw.mixertemp,mixer temperature,uint16 (>=0<=3199),C,false,sensor.boiler_dhw_mixer_temperature,sensor.boiler_dhw_mixertemp,5,9,1/10,64,1 +"Greenstar HIU, Logamax kompakt WS170",boiler,219,dhw.cylmiddletemp,cylinder middle temperature (TS3),uint16 (>=0<=3199),C,false,sensor.boiler_dhw_cylinder_middle_temperature_(TS3),sensor.boiler_dhw_cylmiddletemp,5,9,1/10,65,1 +"Greenstar HIU, Logamax kompakt WS170",boiler,219,dhw.starts,starts,uint24 (>=0<=16777214), ,false,sensor.boiler_dhw_starts,sensor.boiler_dhw_starts,5,9,1,66,2 +"Greenstar HIU, Logamax kompakt WS170",boiler,219,dhw.workm,active time,time (>=0<=16777214),minutes,false,sensor.boiler_dhw_active_time,sensor.boiler_dhw_workm,5,9,1,68,2 "Logamax Plus GB122, Condense 2300, Junkers Cerapur GC2200W",boiler,234,reset,reset,cmd [-\|maintenance\|error\|history\|message], ,true,sensor.boiler_reset,sensor.boiler_reset,5,0,1,0,1 "Logamax Plus GB122, Condense 2300, Junkers Cerapur GC2200W",boiler,234,heatingoff,force heating off,boolean, ,true,switch.boiler_force_heating_off,switch.boiler_heatingoff,5,0,1,1,1 "Logamax Plus GB122, Condense 2300, Junkers Cerapur GC2200W",boiler,234,heatingactive,heating active,boolean, ,false,binary_sensor.boiler_heating_active,binary_sensor.boiler_heatingactive,5,0,1,2,1 @@ -3518,9 +3546,9 @@ device name,device type,product id,shortname,fullname,type [options...] \| (min/ "Logamax Plus GB122, Condense 2300, Junkers Cerapur GC2200W",boiler,234,meterheat,meter heating,uint24 (>=0<=1677721),kWh,false,sensor.boiler_meter_heating,sensor.boiler_meterheat,5,0,1/10,95,2 "Logamax Plus GB122, Condense 2300, Junkers Cerapur GC2200W",boiler,234,dhw.meter,meter,uint24 (>=0<=1677721),kWh,false,sensor.boiler_dhw_meter,sensor.boiler_dhw_meter,5,9,1/10,2,2 "Logamax Plus GB122, Condense 2300, Junkers Cerapur GC2200W",boiler,234,gasmeterheat,gas meter heating,uint24 (>=0<=1677721),kWh,false,sensor.boiler_gas_meter_heating,sensor.boiler_gasmeterheat,5,0,1/10,266,2 -"Logamax Plus GB122, Condense 2300, Junkers Cerapur GC2200W",boiler,234,dhw.gasmeter,gas meter,uint24 (>=0<=1677721),kWh,false,sensor.boiler_dhw_gas_meter,sensor.boiler_dhw_gasmeter,5,9,1/10,69,2 +"Logamax Plus GB122, Condense 2300, Junkers Cerapur GC2200W",boiler,234,dhw.gasmeter,gas meter,uint24 (>=0<=1677721),kWh,false,sensor.boiler_dhw_gas_meter,sensor.boiler_dhw_gasmeter,5,9,1/10,70,2 "Logamax Plus GB122, Condense 2300, Junkers Cerapur GC2200W",boiler,234,nrgheat2,energy heating 2,uint24 (>=0<=1677721),kWh,false,sensor.boiler_energy_heating_2,sensor.boiler_nrgheat2,5,0,1/10,268,2 -"Logamax Plus GB122, Condense 2300, Junkers Cerapur GC2200W",boiler,234,dhw.nrg2,energy 2,uint24 (>=0<=1677721),kWh,false,sensor.boiler_dhw_energy_2,sensor.boiler_dhw_nrg2,5,9,1/10,71,2 +"Logamax Plus GB122, Condense 2300, Junkers Cerapur GC2200W",boiler,234,dhw.nrg2,energy 2,uint24 (>=0<=1677721),kWh,false,sensor.boiler_dhw_energy_2,sensor.boiler_dhw_nrg2,5,9,1/10,72,2 "Logamax Plus GB122, Condense 2300, Junkers Cerapur GC2200W",boiler,234,dhw.tapactivated,turn on/off,boolean, ,true,switch.boiler_dhw_turn_on/off,switch.boiler_dhw_tapactivated,5,9,1,28,1 "Logamax Plus GB122, Condense 2300, Junkers Cerapur GC2200W",boiler,234,dhw.settemp,set temperature,uint8 (>=0<=254),C,false,sensor.boiler_dhw_set_temperature,sensor.boiler_dhw_settemp,5,9,1,29,1 "Logamax Plus GB122, Condense 2300, Junkers Cerapur GC2200W",boiler,234,dhw.seltemp,selected temperature,uint8 (>=0<=254),C,true,number.boiler_dhw_selected_temperature,number.boiler_dhw_seltemp,5,9,1,30,1 @@ -3556,10 +3584,11 @@ device name,device type,product id,shortname,fullname,type [options...] \| (min/ "Logamax Plus GB122, Condense 2300, Junkers Cerapur GC2200W",boiler,234,dhw.tempok,temperature ok,boolean, ,false,binary_sensor.boiler_dhw_temperature_ok,binary_sensor.boiler_dhw_tempok,5,9,1,60,1 "Logamax Plus GB122, Condense 2300, Junkers Cerapur GC2200W",boiler,234,dhw.active,active,boolean, ,false,binary_sensor.boiler_dhw_active,binary_sensor.boiler_dhw_active,5,9,1,61,1 "Logamax Plus GB122, Condense 2300, Junkers Cerapur GC2200W",boiler,234,dhw.3wayvalve,3-way valve active,boolean, ,false,binary_sensor.boiler_dhw_3-way_valve_active,binary_sensor.boiler_dhw_3wayvalve,5,9,1,62,1 -"Logamax Plus GB122, Condense 2300, Junkers Cerapur GC2200W",boiler,234,dhw.mixertemp,mixer temperature,uint16 (>=0<=3199),C,false,sensor.boiler_dhw_mixer_temperature,sensor.boiler_dhw_mixertemp,5,9,1/10,63,1 -"Logamax Plus GB122, Condense 2300, Junkers Cerapur GC2200W",boiler,234,dhw.cylmiddletemp,cylinder middle temperature (TS3),uint16 (>=0<=3199),C,false,sensor.boiler_dhw_cylinder_middle_temperature_(TS3),sensor.boiler_dhw_cylmiddletemp,5,9,1/10,64,1 -"Logamax Plus GB122, Condense 2300, Junkers Cerapur GC2200W",boiler,234,dhw.starts,starts,uint24 (>=0<=16777214), ,false,sensor.boiler_dhw_starts,sensor.boiler_dhw_starts,5,9,1,65,2 -"Logamax Plus GB122, Condense 2300, Junkers Cerapur GC2200W",boiler,234,dhw.workm,active time,time (>=0<=16777214),minutes,false,sensor.boiler_dhw_active_time,sensor.boiler_dhw_workm,5,9,1,67,2 +"Logamax Plus GB122, Condense 2300, Junkers Cerapur GC2200W",boiler,234,dhw.chargepump,charge pump,boolean, ,false,binary_sensor.boiler_dhw_charge_pump,binary_sensor.boiler_dhw_chargepump,5,9,1,63,1 +"Logamax Plus GB122, Condense 2300, Junkers Cerapur GC2200W",boiler,234,dhw.mixertemp,mixer temperature,uint16 (>=0<=3199),C,false,sensor.boiler_dhw_mixer_temperature,sensor.boiler_dhw_mixertemp,5,9,1/10,64,1 +"Logamax Plus GB122, Condense 2300, Junkers Cerapur GC2200W",boiler,234,dhw.cylmiddletemp,cylinder middle temperature (TS3),uint16 (>=0<=3199),C,false,sensor.boiler_dhw_cylinder_middle_temperature_(TS3),sensor.boiler_dhw_cylmiddletemp,5,9,1/10,65,1 +"Logamax Plus GB122, Condense 2300, Junkers Cerapur GC2200W",boiler,234,dhw.starts,starts,uint24 (>=0<=16777214), ,false,sensor.boiler_dhw_starts,sensor.boiler_dhw_starts,5,9,1,66,2 +"Logamax Plus GB122, Condense 2300, Junkers Cerapur GC2200W",boiler,234,dhw.workm,active time,time (>=0<=16777214),minutes,false,sensor.boiler_dhw_active_time,sensor.boiler_dhw_workm,5,9,1,68,2 "Logamax Plus GB122, Condense 2300, Junkers Cerapur GC2200W",boiler,234,nompower,nominal Power,uint8 (>=0<=254),kW,true,number.boiler_nominal_Power,number.boiler_nompower,5,0,1,270,1 "Logamax Plus GB122, Condense 2300, Junkers Cerapur GC2200W",boiler,234,nrgtotal,total energy,uint24 (>=0<=167772),kWh,false,sensor.boiler_total_energy,sensor.boiler_nrgtotal,5,0,1/100,83,2 "Logamax Plus GB122, Condense 2300, Junkers Cerapur GC2200W",boiler,234,nrgheat,energy heating,uint24 (>=0<=10000000),kWh,true,number.boiler_energy_heating,number.boiler_nrgheat,5,0,1/100,85,2 diff --git a/interface/package.json b/interface/package.json index 4fa01c7c6..cdb1e40bb 100644 --- a/interface/package.json +++ b/interface/package.json @@ -27,7 +27,7 @@ "@mui/icons-material": "^7.1.0", "@mui/material": "^7.1.0", "@table-library/react-table-library": "4.1.15", - "alova": "3.2.10", + "alova": "3.2.11", "async-validator": "^4.2.5", "formidable": "^3.5.4", "jwt-decode": "^4.0.0", @@ -48,16 +48,16 @@ "@preact/compat": "^18.3.1", "@preact/preset-vite": "^2.10.1", "@trivago/prettier-plugin-sort-imports": "^5.2.2", - "@types/node": "^22.15.17", - "@types/react": "^19.1.3", - "@types/react-dom": "^19.1.3", + "@types/node": "^22.15.18", + "@types/react": "^19.1.4", + "@types/react-dom": "^19.1.5", "concurrently": "^9.1.2", "eslint": "^9.26.0", "eslint-config-prettier": "^10.1.5", "prettier": "^3.5.3", "rollup-plugin-visualizer": "^5.14.0", - "terser": "^5.39.0", - "typescript-eslint": "8.32.0", + "terser": "^5.39.2", + "typescript-eslint": "8.32.1", "vite": "^6.3.5", "vite-plugin-imagemin": "^0.6.1", "vite-tsconfig-paths": "^5.1.4" diff --git a/interface/yarn.lock b/interface/yarn.lock index 82e00a4df..237ba7874 100644 --- a/interface/yarn.lock +++ b/interface/yarn.lock @@ -33,18 +33,7 @@ __metadata: languageName: node linkType: hard -"@babel/code-frame@npm:^7.0.0, @babel/code-frame@npm:^7.26.2": - version: 7.26.2 - resolution: "@babel/code-frame@npm:7.26.2" - dependencies: - "@babel/helper-validator-identifier": "npm:^7.25.9" - js-tokens: "npm:^4.0.0" - picocolors: "npm:^1.0.0" - checksum: 10c0/7d79621a6849183c415486af99b1a20b84737e8c11cd55b6544f688c51ce1fd710e6d869c3dd21232023da272a79b91efb3e83b5bc2dc65c1187c5fcd1b72ea8 - languageName: node - linkType: hard - -"@babel/code-frame@npm:^7.27.1": +"@babel/code-frame@npm:^7.0.0, @babel/code-frame@npm:^7.27.1": version: 7.27.1 resolution: "@babel/code-frame@npm:7.27.1" dependencies: @@ -55,44 +44,14 @@ __metadata: languageName: node linkType: hard -"@babel/compat-data@npm:^7.26.8": - version: 7.26.8 - resolution: "@babel/compat-data@npm:7.26.8" - checksum: 10c0/66408a0388c3457fff1c2f6c3a061278dd7b3d2f0455ea29bb7b187fa52c60ae8b4054b3c0a184e21e45f0eaac63cf390737bc7504d1f4a088a6e7f652c068ca +"@babel/compat-data@npm:^7.27.2": + version: 7.27.2 + resolution: "@babel/compat-data@npm:7.27.2" + checksum: 10c0/077c9e01af3b90decee384a6a44dcf353898e980cee22ec7941f9074655dbbe97ec317345536cdc7ef7391521e1497930c522a3816af473076dd524be7fccd32 languageName: node linkType: hard -"@babel/compat-data@npm:^7.27.1": - version: 7.27.1 - resolution: "@babel/compat-data@npm:7.27.1" - checksum: 10c0/03e3a01b6772858dc5064f332ad4dc16fbbc0353f2180fd663a2651e8305058e35b6db57114e345d925def9b73cd7a322e95a45913428b8db705a098fd3dd289 - languageName: node - linkType: hard - -"@babel/core@npm:^7.22.1": - version: 7.26.10 - resolution: "@babel/core@npm:7.26.10" - dependencies: - "@ampproject/remapping": "npm:^2.2.0" - "@babel/code-frame": "npm:^7.26.2" - "@babel/generator": "npm:^7.26.10" - "@babel/helper-compilation-targets": "npm:^7.26.5" - "@babel/helper-module-transforms": "npm:^7.26.0" - "@babel/helpers": "npm:^7.26.10" - "@babel/parser": "npm:^7.26.10" - "@babel/template": "npm:^7.26.9" - "@babel/traverse": "npm:^7.26.10" - "@babel/types": "npm:^7.26.10" - convert-source-map: "npm:^2.0.0" - debug: "npm:^4.1.0" - gensync: "npm:^1.0.0-beta.2" - json5: "npm:^2.2.3" - semver: "npm:^6.3.1" - checksum: 10c0/e046e0e988ab53841b512ee9d263ca409f6c46e2a999fe53024688b92db394346fa3aeae5ea0866331f62133982eee05a675d22922a4603c3f603aa09a581d62 - languageName: node - linkType: hard - -"@babel/core@npm:^7.27.1": +"@babel/core@npm:^7.22.1, @babel/core@npm:^7.27.1": version: 7.27.1 resolution: "@babel/core@npm:7.27.1" dependencies: @@ -115,20 +74,7 @@ __metadata: languageName: node linkType: hard -"@babel/generator@npm:^7.26.10, @babel/generator@npm:^7.26.5, @babel/generator@npm:^7.27.0": - version: 7.27.0 - resolution: "@babel/generator@npm:7.27.0" - dependencies: - "@babel/parser": "npm:^7.27.0" - "@babel/types": "npm:^7.27.0" - "@jridgewell/gen-mapping": "npm:^0.3.5" - "@jridgewell/trace-mapping": "npm:^0.3.25" - jsesc: "npm:^3.0.2" - checksum: 10c0/7cb10693d2b365c278f109a745dc08856cae139d262748b77b70ce1d97da84627f79648cab6940d847392c0e5d180441669ed958b3aee98d9c7d274b37c553bd - languageName: node - linkType: hard - -"@babel/generator@npm:^7.27.1": +"@babel/generator@npm:^7.26.5, @babel/generator@npm:^7.27.1": version: 7.27.1 resolution: "@babel/generator@npm:7.27.1" dependencies: @@ -141,52 +87,29 @@ __metadata: languageName: node linkType: hard -"@babel/helper-annotate-as-pure@npm:^7.25.9": - version: 7.25.9 - resolution: "@babel/helper-annotate-as-pure@npm:7.25.9" +"@babel/helper-annotate-as-pure@npm:^7.27.1": + version: 7.27.1 + resolution: "@babel/helper-annotate-as-pure@npm:7.27.1" dependencies: - "@babel/types": "npm:^7.25.9" - checksum: 10c0/095b6ba50489d797733abebc4596a81918316a99e3632755c9f02508882912b00c2ae5e468532a25a5c2108d109ddbe9b7da78333ee7cc13817fc50c00cf06fe - languageName: node - linkType: hard - -"@babel/helper-compilation-targets@npm:^7.26.5": - version: 7.27.0 - resolution: "@babel/helper-compilation-targets@npm:7.27.0" - dependencies: - "@babel/compat-data": "npm:^7.26.8" - "@babel/helper-validator-option": "npm:^7.25.9" - browserslist: "npm:^4.24.0" - lru-cache: "npm:^5.1.1" - semver: "npm:^6.3.1" - checksum: 10c0/375c9f80e6540118f41bd53dd54d670b8bf91235d631bdead44c8b313b26e9cd89aed5c6df770ad13a87a464497b5346bb72b9462ba690473da422f5402618b6 + "@babel/types": "npm:^7.27.1" + checksum: 10c0/fc4751b59c8f5417e1acb0455d6ffce53fa5e79b3aca690299fbbf73b1b65bfaef3d4a18abceb190024c5836bb6cfbc3711e83888648df93df54e18152a1196c languageName: node linkType: hard "@babel/helper-compilation-targets@npm:^7.27.1": - version: 7.27.1 - resolution: "@babel/helper-compilation-targets@npm:7.27.1" + version: 7.27.2 + resolution: "@babel/helper-compilation-targets@npm:7.27.2" dependencies: - "@babel/compat-data": "npm:^7.27.1" + "@babel/compat-data": "npm:^7.27.2" "@babel/helper-validator-option": "npm:^7.27.1" browserslist: "npm:^4.24.0" lru-cache: "npm:^5.1.1" semver: "npm:^6.3.1" - checksum: 10c0/1cfd3760a1bf1e367ea4a91214c041be7076197ba7a4f3c0710cab00fb5734eb010a2946efe6ecfb1ca9dc63e6c69644a1afa399db4082f374b9311e129f6f0b + checksum: 10c0/f338fa00dcfea931804a7c55d1a1c81b6f0a09787e528ec580d5c21b3ecb3913f6cb0f361368973ce953b824d910d3ac3e8a8ee15192710d3563826447193ad1 languageName: node linkType: hard -"@babel/helper-module-imports@npm:^7.16.7, @babel/helper-module-imports@npm:^7.25.9": - version: 7.25.9 - resolution: "@babel/helper-module-imports@npm:7.25.9" - dependencies: - "@babel/traverse": "npm:^7.25.9" - "@babel/types": "npm:^7.25.9" - checksum: 10c0/078d3c2b45d1f97ffe6bb47f61961be4785d2342a4156d8b42c92ee4e1b7b9e365655dd6cb25329e8fe1a675c91eeac7e3d04f0c518b67e417e29d6e27b6aa70 - languageName: node - linkType: hard - -"@babel/helper-module-imports@npm:^7.27.1": +"@babel/helper-module-imports@npm:^7.16.7, @babel/helper-module-imports@npm:^7.27.1": version: 7.27.1 resolution: "@babel/helper-module-imports@npm:7.27.1" dependencies: @@ -196,19 +119,6 @@ __metadata: languageName: node linkType: hard -"@babel/helper-module-transforms@npm:^7.26.0": - version: 7.26.0 - resolution: "@babel/helper-module-transforms@npm:7.26.0" - dependencies: - "@babel/helper-module-imports": "npm:^7.25.9" - "@babel/helper-validator-identifier": "npm:^7.25.9" - "@babel/traverse": "npm:^7.25.9" - peerDependencies: - "@babel/core": ^7.0.0 - checksum: 10c0/ee111b68a5933481d76633dad9cdab30c41df4479f0e5e1cc4756dc9447c1afd2c9473b5ba006362e35b17f4ebddd5fca090233bef8dfc84dca9d9127e56ec3a - languageName: node - linkType: hard - "@babel/helper-module-transforms@npm:^7.27.1": version: 7.27.1 resolution: "@babel/helper-module-transforms@npm:7.27.1" @@ -222,17 +132,10 @@ __metadata: languageName: node linkType: hard -"@babel/helper-plugin-utils@npm:^7.25.9": - version: 7.26.5 - resolution: "@babel/helper-plugin-utils@npm:7.26.5" - checksum: 10c0/cdaba71d4b891aa6a8dfbe5bac2f94effb13e5fa4c2c487667fdbaa04eae059b78b28d85a885071f45f7205aeb56d16759e1bed9c118b94b16e4720ef1ab0f65 - languageName: node - linkType: hard - -"@babel/helper-string-parser@npm:^7.25.9": - version: 7.25.9 - resolution: "@babel/helper-string-parser@npm:7.25.9" - checksum: 10c0/7244b45d8e65f6b4338a6a68a8556f2cb161b782343e97281a5f2b9b93e420cad0d9f5773a59d79f61d0c448913d06f6a2358a87f2e203cf112e3c5b53522ee6 +"@babel/helper-plugin-utils@npm:^7.27.1": + version: 7.27.1 + resolution: "@babel/helper-plugin-utils@npm:7.27.1" + checksum: 10c0/94cf22c81a0c11a09b197b41ab488d416ff62254ce13c57e62912c85700dc2e99e555225787a4099ff6bae7a1812d622c80fbaeda824b79baa10a6c5ac4cf69b languageName: node linkType: hard @@ -243,13 +146,6 @@ __metadata: languageName: node linkType: hard -"@babel/helper-validator-identifier@npm:^7.25.9": - version: 7.25.9 - resolution: "@babel/helper-validator-identifier@npm:7.25.9" - checksum: 10c0/4fc6f830177b7b7e887ad3277ddb3b91d81e6c4a24151540d9d1023e8dc6b1c0505f0f0628ae653601eb4388a8db45c1c14b2c07a9173837aef7e4116456259d - languageName: node - linkType: hard - "@babel/helper-validator-identifier@npm:^7.27.1": version: 7.27.1 resolution: "@babel/helper-validator-identifier@npm:7.27.1" @@ -257,13 +153,6 @@ __metadata: languageName: node linkType: hard -"@babel/helper-validator-option@npm:^7.25.9": - version: 7.25.9 - resolution: "@babel/helper-validator-option@npm:7.25.9" - checksum: 10c0/27fb195d14c7dcb07f14e58fe77c44eea19a6a40a74472ec05c441478fa0bb49fa1c32b2d64be7a38870ee48ef6601bdebe98d512f0253aea0b39756c4014f3e - languageName: node - linkType: hard - "@babel/helper-validator-option@npm:^7.27.1": version: 7.27.1 resolution: "@babel/helper-validator-option@npm:7.27.1" @@ -271,16 +160,6 @@ __metadata: languageName: node linkType: hard -"@babel/helpers@npm:^7.26.10": - version: 7.27.0 - resolution: "@babel/helpers@npm:7.27.0" - dependencies: - "@babel/template": "npm:^7.27.0" - "@babel/types": "npm:^7.27.0" - checksum: 10c0/a3c64fd2d8b164c041808826cc00769d814074ea447daaacaf2e3714b66d3f4237ef6e420f61d08f463d6608f3468c2ac5124ab7c68f704e20384def5ade95f4 - languageName: node - linkType: hard - "@babel/helpers@npm:^7.27.1": version: 7.27.1 resolution: "@babel/helpers@npm:7.27.1" @@ -291,119 +170,73 @@ __metadata: languageName: node linkType: hard -"@babel/parser@npm:^7.26.10, @babel/parser@npm:^7.26.7, @babel/parser@npm:^7.27.0": - version: 7.27.0 - resolution: "@babel/parser@npm:7.27.0" - dependencies: - "@babel/types": "npm:^7.27.0" - bin: - parser: ./bin/babel-parser.js - checksum: 10c0/ba2ed3f41735826546a3ef2a7634a8d10351df221891906e59b29b0a0cd748f9b0e7a6f07576858a9de8e77785aad925c8389ddef146de04ea2842047c9d2859 - languageName: node - linkType: hard - -"@babel/parser@npm:^7.27.1": - version: 7.27.1 - resolution: "@babel/parser@npm:7.27.1" +"@babel/parser@npm:^7.26.7, @babel/parser@npm:^7.27.1, @babel/parser@npm:^7.27.2": + version: 7.27.2 + resolution: "@babel/parser@npm:7.27.2" dependencies: "@babel/types": "npm:^7.27.1" bin: parser: ./bin/babel-parser.js - checksum: 10c0/ae4a5eda3ada3fd54c9942d9f14385df7a18e71b386cf2652505bb9a40a32250dfde3bdda71fb08af00b1e154f0a6213e6cdaaa88e9941229ec0003f7fead759 + checksum: 10c0/3c06692768885c2f58207fc8c2cbdb4a44df46b7d93135a083f6eaa49310f7ced490ce76043a2a7606cdcc13f27e3d835e141b692f2f6337a2e7f43c1dbb04b4 languageName: node linkType: hard -"@babel/plugin-syntax-jsx@npm:^7.25.9": - version: 7.25.9 - resolution: "@babel/plugin-syntax-jsx@npm:7.25.9" +"@babel/plugin-syntax-jsx@npm:^7.27.1": + version: 7.27.1 + resolution: "@babel/plugin-syntax-jsx@npm:7.27.1" dependencies: - "@babel/helper-plugin-utils": "npm:^7.25.9" + "@babel/helper-plugin-utils": "npm:^7.27.1" peerDependencies: "@babel/core": ^7.0.0-0 - checksum: 10c0/d56597aff4df39d3decda50193b6dfbe596ca53f437ff2934622ce19a743bf7f43492d3fb3308b0289f5cee2b825d99ceb56526a2b9e7b68bf04901546c5618c + checksum: 10c0/bc5afe6a458d5f0492c02a54ad98c5756a0c13bd6d20609aae65acd560a9e141b0876da5f358dce34ea136f271c1016df58b461184d7ae9c4321e0f98588bc84 languageName: node linkType: hard "@babel/plugin-transform-react-jsx-development@npm:^7.22.5": - version: 7.25.9 - resolution: "@babel/plugin-transform-react-jsx-development@npm:7.25.9" + version: 7.27.1 + resolution: "@babel/plugin-transform-react-jsx-development@npm:7.27.1" dependencies: - "@babel/plugin-transform-react-jsx": "npm:^7.25.9" + "@babel/plugin-transform-react-jsx": "npm:^7.27.1" peerDependencies: "@babel/core": ^7.0.0-0 - checksum: 10c0/c0b92ff9eb029620abf320ff74aae182cea87524723d740fb48a4373d0d16bddf5edbe1116e7ba341332a5337e55c2ceaee8b8cad5549e78af7f4b3cfe77debb + checksum: 10c0/eb8c4b6a79dc5c49b41e928e2037e1ee0bbfa722e4fd74c0b7c0d11103c82c2c25c434000e1b051d534c7261ab5c92b6d1e85313bf1b26e37db3f051ae217b58 languageName: node linkType: hard -"@babel/plugin-transform-react-jsx@npm:^7.22.15, @babel/plugin-transform-react-jsx@npm:^7.25.9": - version: 7.25.9 - resolution: "@babel/plugin-transform-react-jsx@npm:7.25.9" +"@babel/plugin-transform-react-jsx@npm:^7.22.15, @babel/plugin-transform-react-jsx@npm:^7.27.1": + version: 7.27.1 + resolution: "@babel/plugin-transform-react-jsx@npm:7.27.1" dependencies: - "@babel/helper-annotate-as-pure": "npm:^7.25.9" - "@babel/helper-module-imports": "npm:^7.25.9" - "@babel/helper-plugin-utils": "npm:^7.25.9" - "@babel/plugin-syntax-jsx": "npm:^7.25.9" - "@babel/types": "npm:^7.25.9" + "@babel/helper-annotate-as-pure": "npm:^7.27.1" + "@babel/helper-module-imports": "npm:^7.27.1" + "@babel/helper-plugin-utils": "npm:^7.27.1" + "@babel/plugin-syntax-jsx": "npm:^7.27.1" + "@babel/types": "npm:^7.27.1" peerDependencies: "@babel/core": ^7.0.0-0 - checksum: 10c0/5c9947e8ed141f7606f54da3e05eea1074950c5b8354c39df69cb7f43cb5a83c6c9d7973b24bc3d89341c8611f8ad50830a98ab10d117d850e6bdd8febdce221 + checksum: 10c0/1a08637c39fc78c9760dd4a3ed363fdbc762994bf83ed7872ad5bda0232fcd0fc557332f2ce36b522c0226dfd9cc8faac6b88eddda535f24825198a689e571af languageName: node linkType: hard -"@babel/runtime@npm:^7.0.0, @babel/runtime@npm:^7.12.5, @babel/runtime@npm:^7.18.3, @babel/runtime@npm:^7.5.5, @babel/runtime@npm:^7.8.7": - version: 7.27.0 - resolution: "@babel/runtime@npm:7.27.0" - dependencies: - regenerator-runtime: "npm:^0.14.0" - checksum: 10c0/35091ea9de48bd7fd26fb177693d64f4d195eb58ab2b142b893b7f3fa0f1d7c677604d36499ae0621a3703f35ba0c6a8f6c572cc8f7dc0317213841e493cf663 - languageName: node - linkType: hard - -"@babel/runtime@npm:^7.27.1": +"@babel/runtime@npm:^7.0.0, @babel/runtime@npm:^7.12.5, @babel/runtime@npm:^7.18.3, @babel/runtime@npm:^7.27.1, @babel/runtime@npm:^7.5.5, @babel/runtime@npm:^7.8.7": version: 7.27.1 resolution: "@babel/runtime@npm:7.27.1" checksum: 10c0/530a7332f86ac5a7442250456823a930906911d895c0b743bf1852efc88a20a016ed4cd26d442d0ca40ae6d5448111e02a08dd638a4f1064b47d080e2875dc05 languageName: node linkType: hard -"@babel/template@npm:^7.26.9, @babel/template@npm:^7.27.0": - version: 7.27.0 - resolution: "@babel/template@npm:7.27.0" - dependencies: - "@babel/code-frame": "npm:^7.26.2" - "@babel/parser": "npm:^7.27.0" - "@babel/types": "npm:^7.27.0" - checksum: 10c0/13af543756127edb5f62bf121f9b093c09a2b6fe108373887ccffc701465cfbcb17e07cf48aa7f440415b263f6ec006e9415c79dfc2e8e6010b069435f81f340 - languageName: node - linkType: hard - "@babel/template@npm:^7.27.1": - version: 7.27.1 - resolution: "@babel/template@npm:7.27.1" + version: 7.27.2 + resolution: "@babel/template@npm:7.27.2" dependencies: "@babel/code-frame": "npm:^7.27.1" - "@babel/parser": "npm:^7.27.1" + "@babel/parser": "npm:^7.27.2" "@babel/types": "npm:^7.27.1" - checksum: 10c0/155a8e056e82f1f1e2413b7bf9d96890e371d617c7f77f25621fb0ddb32128958d86bc5c3356f00be266e9f8c121d886de5b4143dbb72eac362377f53aba72a2 + checksum: 10c0/ed9e9022651e463cc5f2cc21942f0e74544f1754d231add6348ff1b472985a3b3502041c0be62dc99ed2d12cfae0c51394bf827452b98a2f8769c03b87aadc81 languageName: node linkType: hard -"@babel/traverse@npm:^7.25.9, @babel/traverse@npm:^7.26.10, @babel/traverse@npm:^7.26.7": - version: 7.27.0 - resolution: "@babel/traverse@npm:7.27.0" - dependencies: - "@babel/code-frame": "npm:^7.26.2" - "@babel/generator": "npm:^7.27.0" - "@babel/parser": "npm:^7.27.0" - "@babel/template": "npm:^7.27.0" - "@babel/types": "npm:^7.27.0" - debug: "npm:^4.3.1" - globals: "npm:^11.1.0" - checksum: 10c0/c7af29781960dacaae51762e8bc6c4b13d6ab4b17312990fbca9fc38e19c4ad7fecaae24b1cf52fb844e8e6cdc76c70ad597f90e496bcb3cc0a1d66b41a0aa5b - languageName: node - linkType: hard - -"@babel/traverse@npm:^7.27.1": +"@babel/traverse@npm:^7.26.7, @babel/traverse@npm:^7.27.1": version: 7.27.1 resolution: "@babel/traverse@npm:7.27.1" dependencies: @@ -418,17 +251,7 @@ __metadata: languageName: node linkType: hard -"@babel/types@npm:^7.25.9, @babel/types@npm:^7.26.10, @babel/types@npm:^7.26.7, @babel/types@npm:^7.27.0": - version: 7.27.0 - resolution: "@babel/types@npm:7.27.0" - dependencies: - "@babel/helper-string-parser": "npm:^7.25.9" - "@babel/helper-validator-identifier": "npm:^7.25.9" - checksum: 10c0/6f1592eabe243c89a608717b07b72969be9d9d2fce1dee21426238757ea1fa60fdfc09b29de9e48d8104311afc6e6fb1702565a9cc1e09bc1e76f2b2ddb0f6e1 - languageName: node - linkType: hard - -"@babel/types@npm:^7.27.1": +"@babel/types@npm:^7.26.7, @babel/types@npm:^7.27.1": version: 7.27.1 resolution: "@babel/types@npm:7.27.1" dependencies: @@ -584,79 +407,79 @@ __metadata: languageName: node linkType: hard -"@esbuild/aix-ppc64@npm:0.25.3": - version: 0.25.3 - resolution: "@esbuild/aix-ppc64@npm:0.25.3" +"@esbuild/aix-ppc64@npm:0.25.4": + version: 0.25.4 + resolution: "@esbuild/aix-ppc64@npm:0.25.4" conditions: os=aix & cpu=ppc64 languageName: node linkType: hard -"@esbuild/android-arm64@npm:0.25.3": - version: 0.25.3 - resolution: "@esbuild/android-arm64@npm:0.25.3" +"@esbuild/android-arm64@npm:0.25.4": + version: 0.25.4 + resolution: "@esbuild/android-arm64@npm:0.25.4" conditions: os=android & cpu=arm64 languageName: node linkType: hard -"@esbuild/android-arm@npm:0.25.3": - version: 0.25.3 - resolution: "@esbuild/android-arm@npm:0.25.3" +"@esbuild/android-arm@npm:0.25.4": + version: 0.25.4 + resolution: "@esbuild/android-arm@npm:0.25.4" conditions: os=android & cpu=arm languageName: node linkType: hard -"@esbuild/android-x64@npm:0.25.3": - version: 0.25.3 - resolution: "@esbuild/android-x64@npm:0.25.3" +"@esbuild/android-x64@npm:0.25.4": + version: 0.25.4 + resolution: "@esbuild/android-x64@npm:0.25.4" conditions: os=android & cpu=x64 languageName: node linkType: hard -"@esbuild/darwin-arm64@npm:0.25.3": - version: 0.25.3 - resolution: "@esbuild/darwin-arm64@npm:0.25.3" +"@esbuild/darwin-arm64@npm:0.25.4": + version: 0.25.4 + resolution: "@esbuild/darwin-arm64@npm:0.25.4" conditions: os=darwin & cpu=arm64 languageName: node linkType: hard -"@esbuild/darwin-x64@npm:0.25.3": - version: 0.25.3 - resolution: "@esbuild/darwin-x64@npm:0.25.3" +"@esbuild/darwin-x64@npm:0.25.4": + version: 0.25.4 + resolution: "@esbuild/darwin-x64@npm:0.25.4" conditions: os=darwin & cpu=x64 languageName: node linkType: hard -"@esbuild/freebsd-arm64@npm:0.25.3": - version: 0.25.3 - resolution: "@esbuild/freebsd-arm64@npm:0.25.3" +"@esbuild/freebsd-arm64@npm:0.25.4": + version: 0.25.4 + resolution: "@esbuild/freebsd-arm64@npm:0.25.4" conditions: os=freebsd & cpu=arm64 languageName: node linkType: hard -"@esbuild/freebsd-x64@npm:0.25.3": - version: 0.25.3 - resolution: "@esbuild/freebsd-x64@npm:0.25.3" +"@esbuild/freebsd-x64@npm:0.25.4": + version: 0.25.4 + resolution: "@esbuild/freebsd-x64@npm:0.25.4" conditions: os=freebsd & cpu=x64 languageName: node linkType: hard -"@esbuild/linux-arm64@npm:0.25.3": - version: 0.25.3 - resolution: "@esbuild/linux-arm64@npm:0.25.3" +"@esbuild/linux-arm64@npm:0.25.4": + version: 0.25.4 + resolution: "@esbuild/linux-arm64@npm:0.25.4" conditions: os=linux & cpu=arm64 languageName: node linkType: hard -"@esbuild/linux-arm@npm:0.25.3": - version: 0.25.3 - resolution: "@esbuild/linux-arm@npm:0.25.3" +"@esbuild/linux-arm@npm:0.25.4": + version: 0.25.4 + resolution: "@esbuild/linux-arm@npm:0.25.4" conditions: os=linux & cpu=arm languageName: node linkType: hard -"@esbuild/linux-ia32@npm:0.25.3": - version: 0.25.3 - resolution: "@esbuild/linux-ia32@npm:0.25.3" +"@esbuild/linux-ia32@npm:0.25.4": + version: 0.25.4 + resolution: "@esbuild/linux-ia32@npm:0.25.4" conditions: os=linux & cpu=ia32 languageName: node linkType: hard @@ -668,116 +491,105 @@ __metadata: languageName: node linkType: hard -"@esbuild/linux-loong64@npm:0.25.3": - version: 0.25.3 - resolution: "@esbuild/linux-loong64@npm:0.25.3" +"@esbuild/linux-loong64@npm:0.25.4": + version: 0.25.4 + resolution: "@esbuild/linux-loong64@npm:0.25.4" conditions: os=linux & cpu=loong64 languageName: node linkType: hard -"@esbuild/linux-mips64el@npm:0.25.3": - version: 0.25.3 - resolution: "@esbuild/linux-mips64el@npm:0.25.3" +"@esbuild/linux-mips64el@npm:0.25.4": + version: 0.25.4 + resolution: "@esbuild/linux-mips64el@npm:0.25.4" conditions: os=linux & cpu=mips64el languageName: node linkType: hard -"@esbuild/linux-ppc64@npm:0.25.3": - version: 0.25.3 - resolution: "@esbuild/linux-ppc64@npm:0.25.3" +"@esbuild/linux-ppc64@npm:0.25.4": + version: 0.25.4 + resolution: "@esbuild/linux-ppc64@npm:0.25.4" conditions: os=linux & cpu=ppc64 languageName: node linkType: hard -"@esbuild/linux-riscv64@npm:0.25.3": - version: 0.25.3 - resolution: "@esbuild/linux-riscv64@npm:0.25.3" +"@esbuild/linux-riscv64@npm:0.25.4": + version: 0.25.4 + resolution: "@esbuild/linux-riscv64@npm:0.25.4" conditions: os=linux & cpu=riscv64 languageName: node linkType: hard -"@esbuild/linux-s390x@npm:0.25.3": - version: 0.25.3 - resolution: "@esbuild/linux-s390x@npm:0.25.3" +"@esbuild/linux-s390x@npm:0.25.4": + version: 0.25.4 + resolution: "@esbuild/linux-s390x@npm:0.25.4" conditions: os=linux & cpu=s390x languageName: node linkType: hard -"@esbuild/linux-x64@npm:0.25.3": - version: 0.25.3 - resolution: "@esbuild/linux-x64@npm:0.25.3" +"@esbuild/linux-x64@npm:0.25.4": + version: 0.25.4 + resolution: "@esbuild/linux-x64@npm:0.25.4" conditions: os=linux & cpu=x64 languageName: node linkType: hard -"@esbuild/netbsd-arm64@npm:0.25.3": - version: 0.25.3 - resolution: "@esbuild/netbsd-arm64@npm:0.25.3" +"@esbuild/netbsd-arm64@npm:0.25.4": + version: 0.25.4 + resolution: "@esbuild/netbsd-arm64@npm:0.25.4" conditions: os=netbsd & cpu=arm64 languageName: node linkType: hard -"@esbuild/netbsd-x64@npm:0.25.3": - version: 0.25.3 - resolution: "@esbuild/netbsd-x64@npm:0.25.3" +"@esbuild/netbsd-x64@npm:0.25.4": + version: 0.25.4 + resolution: "@esbuild/netbsd-x64@npm:0.25.4" conditions: os=netbsd & cpu=x64 languageName: node linkType: hard -"@esbuild/openbsd-arm64@npm:0.25.3": - version: 0.25.3 - resolution: "@esbuild/openbsd-arm64@npm:0.25.3" +"@esbuild/openbsd-arm64@npm:0.25.4": + version: 0.25.4 + resolution: "@esbuild/openbsd-arm64@npm:0.25.4" conditions: os=openbsd & cpu=arm64 languageName: node linkType: hard -"@esbuild/openbsd-x64@npm:0.25.3": - version: 0.25.3 - resolution: "@esbuild/openbsd-x64@npm:0.25.3" +"@esbuild/openbsd-x64@npm:0.25.4": + version: 0.25.4 + resolution: "@esbuild/openbsd-x64@npm:0.25.4" conditions: os=openbsd & cpu=x64 languageName: node linkType: hard -"@esbuild/sunos-x64@npm:0.25.3": - version: 0.25.3 - resolution: "@esbuild/sunos-x64@npm:0.25.3" +"@esbuild/sunos-x64@npm:0.25.4": + version: 0.25.4 + resolution: "@esbuild/sunos-x64@npm:0.25.4" conditions: os=sunos & cpu=x64 languageName: node linkType: hard -"@esbuild/win32-arm64@npm:0.25.3": - version: 0.25.3 - resolution: "@esbuild/win32-arm64@npm:0.25.3" +"@esbuild/win32-arm64@npm:0.25.4": + version: 0.25.4 + resolution: "@esbuild/win32-arm64@npm:0.25.4" conditions: os=win32 & cpu=arm64 languageName: node linkType: hard -"@esbuild/win32-ia32@npm:0.25.3": - version: 0.25.3 - resolution: "@esbuild/win32-ia32@npm:0.25.3" +"@esbuild/win32-ia32@npm:0.25.4": + version: 0.25.4 + resolution: "@esbuild/win32-ia32@npm:0.25.4" conditions: os=win32 & cpu=ia32 languageName: node linkType: hard -"@esbuild/win32-x64@npm:0.25.3": - version: 0.25.3 - resolution: "@esbuild/win32-x64@npm:0.25.3" +"@esbuild/win32-x64@npm:0.25.4": + version: 0.25.4 + resolution: "@esbuild/win32-x64@npm:0.25.4" conditions: os=win32 & cpu=x64 languageName: node linkType: hard -"@eslint-community/eslint-utils@npm:^4.2.0": - version: 4.6.1 - resolution: "@eslint-community/eslint-utils@npm:4.6.1" - dependencies: - eslint-visitor-keys: "npm:^3.4.3" - peerDependencies: - eslint: ^6.0.0 || ^7.0.0 || >=8.0.0 - checksum: 10c0/cdeb6f8fc33a83726357d7f736075cdbd6e79dc7ac4b00b15680f1111d0f33bda583e7fafa5937245a058cc66302dc47568bba57b251302dc74964d8e87f56d7 - languageName: node - linkType: hard - -"@eslint-community/eslint-utils@npm:^4.7.0": +"@eslint-community/eslint-utils@npm:^4.2.0, @eslint-community/eslint-utils@npm:^4.7.0": version: 4.7.0 resolution: "@eslint-community/eslint-utils@npm:4.7.0" dependencies: @@ -807,9 +619,9 @@ __metadata: linkType: hard "@eslint/config-helpers@npm:^0.2.1": - version: 0.2.1 - resolution: "@eslint/config-helpers@npm:0.2.1" - checksum: 10c0/3e829a78b0bb4f7c44384ba1df3986e5de24b7f440ad5c6bb3cfc366ded773a869ca9ee8d212b5a563ae94596c5940dea6fd2ea1ee53a84c6241ac953dcb8bb7 + version: 0.2.2 + resolution: "@eslint/config-helpers@npm:0.2.2" + checksum: 10c0/98f7cefe484bb754674585d9e73cf1414a3ab4fd0783c385465288d13eb1a8d8e7d7b0611259fc52b76b396c11a13517be5036d1f48eeb877f6f0a6b9c4f03ad languageName: node linkType: hard @@ -895,9 +707,9 @@ __metadata: linkType: hard "@humanwhocodes/retry@npm:^0.4.2": - version: 0.4.2 - resolution: "@humanwhocodes/retry@npm:0.4.2" - checksum: 10c0/0235525d38f243bee3bf8b25ed395fbf957fb51c08adae52787e1325673071abe856c7e18e530922ed2dd3ce12ed82ba01b8cee0279ac52a3315fcdc3a69ef0c + version: 0.4.3 + resolution: "@humanwhocodes/retry@npm:0.4.3" + checksum: 10c0/3775bb30087d4440b3f7406d5a057777d90e4b9f435af488a4923ef249e93615fb78565a85f173a186a076c7706a81d0d57d563a2624e4de2c5c9c66c486ce42 languageName: node linkType: hard @@ -977,12 +789,12 @@ __metadata: linkType: hard "@modelcontextprotocol/sdk@npm:^1.8.0": - version: 1.11.0 - resolution: "@modelcontextprotocol/sdk@npm:1.11.0" + version: 1.11.3 + resolution: "@modelcontextprotocol/sdk@npm:1.11.3" dependencies: content-type: "npm:^1.0.5" cors: "npm:^2.8.5" - cross-spawn: "npm:^7.0.3" + cross-spawn: "npm:^7.0.5" eventsource: "npm:^3.0.2" express: "npm:^5.0.1" express-rate-limit: "npm:^7.5.0" @@ -990,7 +802,7 @@ __metadata: raw-body: "npm:^3.0.0" zod: "npm:^3.23.8" zod-to-json-schema: "npm:^3.24.1" - checksum: 10c0/10ce5ebe54b238df614051e0f2ef8f037fee6ceda7a870f5892c84efe21cbdcdb7e932d9be25e91982e0eb40e4c8ed33da9b0b2ca01df6baa76eb0cd5cb89ce6 + checksum: 10c0/5bcaf6fb97d886e1a262ba9b44ede91c209bb474a2e5193c9f7d9e2c82829d83775e50f5c37977bc156376e0eca84837da531fe0dfafdc5ad8921db4bf5039c0 languageName: node linkType: hard @@ -1311,142 +1123,142 @@ __metadata: languageName: node linkType: hard -"@rollup/rollup-android-arm-eabi@npm:4.40.0": - version: 4.40.0 - resolution: "@rollup/rollup-android-arm-eabi@npm:4.40.0" +"@rollup/rollup-android-arm-eabi@npm:4.40.2": + version: 4.40.2 + resolution: "@rollup/rollup-android-arm-eabi@npm:4.40.2" conditions: os=android & cpu=arm languageName: node linkType: hard -"@rollup/rollup-android-arm64@npm:4.40.0": - version: 4.40.0 - resolution: "@rollup/rollup-android-arm64@npm:4.40.0" +"@rollup/rollup-android-arm64@npm:4.40.2": + version: 4.40.2 + resolution: "@rollup/rollup-android-arm64@npm:4.40.2" conditions: os=android & cpu=arm64 languageName: node linkType: hard -"@rollup/rollup-darwin-arm64@npm:4.40.0": - version: 4.40.0 - resolution: "@rollup/rollup-darwin-arm64@npm:4.40.0" +"@rollup/rollup-darwin-arm64@npm:4.40.2": + version: 4.40.2 + resolution: "@rollup/rollup-darwin-arm64@npm:4.40.2" conditions: os=darwin & cpu=arm64 languageName: node linkType: hard -"@rollup/rollup-darwin-x64@npm:4.40.0": - version: 4.40.0 - resolution: "@rollup/rollup-darwin-x64@npm:4.40.0" +"@rollup/rollup-darwin-x64@npm:4.40.2": + version: 4.40.2 + resolution: "@rollup/rollup-darwin-x64@npm:4.40.2" conditions: os=darwin & cpu=x64 languageName: node linkType: hard -"@rollup/rollup-freebsd-arm64@npm:4.40.0": - version: 4.40.0 - resolution: "@rollup/rollup-freebsd-arm64@npm:4.40.0" +"@rollup/rollup-freebsd-arm64@npm:4.40.2": + version: 4.40.2 + resolution: "@rollup/rollup-freebsd-arm64@npm:4.40.2" conditions: os=freebsd & cpu=arm64 languageName: node linkType: hard -"@rollup/rollup-freebsd-x64@npm:4.40.0": - version: 4.40.0 - resolution: "@rollup/rollup-freebsd-x64@npm:4.40.0" +"@rollup/rollup-freebsd-x64@npm:4.40.2": + version: 4.40.2 + resolution: "@rollup/rollup-freebsd-x64@npm:4.40.2" conditions: os=freebsd & cpu=x64 languageName: node linkType: hard -"@rollup/rollup-linux-arm-gnueabihf@npm:4.40.0": - version: 4.40.0 - resolution: "@rollup/rollup-linux-arm-gnueabihf@npm:4.40.0" +"@rollup/rollup-linux-arm-gnueabihf@npm:4.40.2": + version: 4.40.2 + resolution: "@rollup/rollup-linux-arm-gnueabihf@npm:4.40.2" conditions: os=linux & cpu=arm & libc=glibc languageName: node linkType: hard -"@rollup/rollup-linux-arm-musleabihf@npm:4.40.0": - version: 4.40.0 - resolution: "@rollup/rollup-linux-arm-musleabihf@npm:4.40.0" +"@rollup/rollup-linux-arm-musleabihf@npm:4.40.2": + version: 4.40.2 + resolution: "@rollup/rollup-linux-arm-musleabihf@npm:4.40.2" conditions: os=linux & cpu=arm & libc=musl languageName: node linkType: hard -"@rollup/rollup-linux-arm64-gnu@npm:4.40.0": - version: 4.40.0 - resolution: "@rollup/rollup-linux-arm64-gnu@npm:4.40.0" +"@rollup/rollup-linux-arm64-gnu@npm:4.40.2": + version: 4.40.2 + resolution: "@rollup/rollup-linux-arm64-gnu@npm:4.40.2" conditions: os=linux & cpu=arm64 & libc=glibc languageName: node linkType: hard -"@rollup/rollup-linux-arm64-musl@npm:4.40.0": - version: 4.40.0 - resolution: "@rollup/rollup-linux-arm64-musl@npm:4.40.0" +"@rollup/rollup-linux-arm64-musl@npm:4.40.2": + version: 4.40.2 + resolution: "@rollup/rollup-linux-arm64-musl@npm:4.40.2" conditions: os=linux & cpu=arm64 & libc=musl languageName: node linkType: hard -"@rollup/rollup-linux-loongarch64-gnu@npm:4.40.0": - version: 4.40.0 - resolution: "@rollup/rollup-linux-loongarch64-gnu@npm:4.40.0" +"@rollup/rollup-linux-loongarch64-gnu@npm:4.40.2": + version: 4.40.2 + resolution: "@rollup/rollup-linux-loongarch64-gnu@npm:4.40.2" conditions: os=linux & cpu=loong64 & libc=glibc languageName: node linkType: hard -"@rollup/rollup-linux-powerpc64le-gnu@npm:4.40.0": - version: 4.40.0 - resolution: "@rollup/rollup-linux-powerpc64le-gnu@npm:4.40.0" +"@rollup/rollup-linux-powerpc64le-gnu@npm:4.40.2": + version: 4.40.2 + resolution: "@rollup/rollup-linux-powerpc64le-gnu@npm:4.40.2" conditions: os=linux & cpu=ppc64 & libc=glibc languageName: node linkType: hard -"@rollup/rollup-linux-riscv64-gnu@npm:4.40.0": - version: 4.40.0 - resolution: "@rollup/rollup-linux-riscv64-gnu@npm:4.40.0" +"@rollup/rollup-linux-riscv64-gnu@npm:4.40.2": + version: 4.40.2 + resolution: "@rollup/rollup-linux-riscv64-gnu@npm:4.40.2" conditions: os=linux & cpu=riscv64 & libc=glibc languageName: node linkType: hard -"@rollup/rollup-linux-riscv64-musl@npm:4.40.0": - version: 4.40.0 - resolution: "@rollup/rollup-linux-riscv64-musl@npm:4.40.0" +"@rollup/rollup-linux-riscv64-musl@npm:4.40.2": + version: 4.40.2 + resolution: "@rollup/rollup-linux-riscv64-musl@npm:4.40.2" conditions: os=linux & cpu=riscv64 & libc=musl languageName: node linkType: hard -"@rollup/rollup-linux-s390x-gnu@npm:4.40.0": - version: 4.40.0 - resolution: "@rollup/rollup-linux-s390x-gnu@npm:4.40.0" +"@rollup/rollup-linux-s390x-gnu@npm:4.40.2": + version: 4.40.2 + resolution: "@rollup/rollup-linux-s390x-gnu@npm:4.40.2" conditions: os=linux & cpu=s390x & libc=glibc languageName: node linkType: hard -"@rollup/rollup-linux-x64-gnu@npm:4.40.0": - version: 4.40.0 - resolution: "@rollup/rollup-linux-x64-gnu@npm:4.40.0" +"@rollup/rollup-linux-x64-gnu@npm:4.40.2": + version: 4.40.2 + resolution: "@rollup/rollup-linux-x64-gnu@npm:4.40.2" conditions: os=linux & cpu=x64 & libc=glibc languageName: node linkType: hard -"@rollup/rollup-linux-x64-musl@npm:4.40.0": - version: 4.40.0 - resolution: "@rollup/rollup-linux-x64-musl@npm:4.40.0" +"@rollup/rollup-linux-x64-musl@npm:4.40.2": + version: 4.40.2 + resolution: "@rollup/rollup-linux-x64-musl@npm:4.40.2" conditions: os=linux & cpu=x64 & libc=musl languageName: node linkType: hard -"@rollup/rollup-win32-arm64-msvc@npm:4.40.0": - version: 4.40.0 - resolution: "@rollup/rollup-win32-arm64-msvc@npm:4.40.0" +"@rollup/rollup-win32-arm64-msvc@npm:4.40.2": + version: 4.40.2 + resolution: "@rollup/rollup-win32-arm64-msvc@npm:4.40.2" conditions: os=win32 & cpu=arm64 languageName: node linkType: hard -"@rollup/rollup-win32-ia32-msvc@npm:4.40.0": - version: 4.40.0 - resolution: "@rollup/rollup-win32-ia32-msvc@npm:4.40.0" +"@rollup/rollup-win32-ia32-msvc@npm:4.40.2": + version: 4.40.2 + resolution: "@rollup/rollup-win32-ia32-msvc@npm:4.40.2" conditions: os=win32 & cpu=ia32 languageName: node linkType: hard -"@rollup/rollup-win32-x64-msvc@npm:4.40.0": - version: 4.40.0 - resolution: "@rollup/rollup-win32-x64-msvc@npm:4.40.0" +"@rollup/rollup-win32-x64-msvc@npm:4.40.2": + version: 4.40.2 + resolution: "@rollup/rollup-win32-x64-msvc@npm:4.40.2" conditions: os=win32 & cpu=x64 languageName: node linkType: hard @@ -1619,21 +1431,12 @@ __metadata: languageName: node linkType: hard -"@types/node@npm:*": - version: 22.15.2 - resolution: "@types/node@npm:22.15.2" +"@types/node@npm:*, @types/node@npm:^22.15.18": + version: 22.15.18 + resolution: "@types/node@npm:22.15.18" dependencies: undici-types: "npm:~6.21.0" - checksum: 10c0/39da31d5fc63b14fabd217bb8a921c4a7fc3d99f233440209f9fc2d5d736e8773f7efc65223e2fd0e8db8390b0baab9c0cd2e951c2ece8b237f07313ab3cf295 - languageName: node - linkType: hard - -"@types/node@npm:^22.15.17": - version: 22.15.17 - resolution: "@types/node@npm:22.15.17" - dependencies: - undici-types: "npm:~6.21.0" - checksum: 10c0/fb92aa10b628683c5b965749f955bc2322485ecb0ea6c2f4cae5f2c7537a16834607e67083a9e9281faaae8d7dee9ada8d6a5c0de9a52c17d82912ef00c0fdd4 + checksum: 10c0/e23178c568e2dc6b93b6aa3b8dfb45f9556e527918c947fe7406a4c92d2184c7396558912400c3b1b8d0fa952ec63819aca2b8e4d3545455fc6f1e9623e09ca6 languageName: node linkType: hard @@ -1651,12 +1454,12 @@ __metadata: languageName: node linkType: hard -"@types/react-dom@npm:^19.1.3": - version: 19.1.3 - resolution: "@types/react-dom@npm:19.1.3" +"@types/react-dom@npm:^19.1.5": + version: 19.1.5 + resolution: "@types/react-dom@npm:19.1.5" peerDependencies: "@types/react": ^19.0.0 - checksum: 10c0/bb1e3f7a446958f5aa7e46f74cf8470dab7444ab958a57efacca1abcc9847e4ca71e2df68515176ed8fe3fc89315bd949d60f1f346cbadbdbf302bff59d3961b + checksum: 10c0/2a29e77cf6bb6e9f57bcfa54509c216cad2e16e244f0bd56369966ec88c072b9c91f6011d14f9e18fbfe2b801b18b86f616de75e5c8aef0be73c1f74abb33b49 languageName: node linkType: hard @@ -1669,12 +1472,12 @@ __metadata: languageName: node linkType: hard -"@types/react@npm:^19.1.3": - version: 19.1.3 - resolution: "@types/react@npm:19.1.3" +"@types/react@npm:^19.1.4": + version: 19.1.4 + resolution: "@types/react@npm:19.1.4" dependencies: csstype: "npm:^3.0.2" - checksum: 10c0/f158f88871b8df1eeed637942d3e6142abcf505b617e4921ef3763b6d4f22241b9a883d864878dd2b6a2bdc8f4e7f871f24ef88f633d144a63257f4764b9478d + checksum: 10c0/501350d4f9cef13c5dd1b1496fa70ebaff52f6fa359b623b51c9d817e5bc4333fa3c8b7a6a4cbc88c643385052d66a243c3ceccfd6926062f917a2dd0535f6b3 languageName: node linkType: hard @@ -1696,81 +1499,81 @@ __metadata: languageName: node linkType: hard -"@typescript-eslint/eslint-plugin@npm:8.32.0": - version: 8.32.0 - resolution: "@typescript-eslint/eslint-plugin@npm:8.32.0" +"@typescript-eslint/eslint-plugin@npm:8.32.1": + version: 8.32.1 + resolution: "@typescript-eslint/eslint-plugin@npm:8.32.1" dependencies: "@eslint-community/regexpp": "npm:^4.10.0" - "@typescript-eslint/scope-manager": "npm:8.32.0" - "@typescript-eslint/type-utils": "npm:8.32.0" - "@typescript-eslint/utils": "npm:8.32.0" - "@typescript-eslint/visitor-keys": "npm:8.32.0" + "@typescript-eslint/scope-manager": "npm:8.32.1" + "@typescript-eslint/type-utils": "npm:8.32.1" + "@typescript-eslint/utils": "npm:8.32.1" + "@typescript-eslint/visitor-keys": "npm:8.32.1" graphemer: "npm:^1.4.0" - ignore: "npm:^5.3.1" + ignore: "npm:^7.0.0" natural-compare: "npm:^1.4.0" ts-api-utils: "npm:^2.1.0" peerDependencies: "@typescript-eslint/parser": ^8.0.0 || ^8.0.0-alpha.0 eslint: ^8.57.0 || ^9.0.0 typescript: ">=4.8.4 <5.9.0" - checksum: 10c0/db3d151386d7f086a2289ff21c12bff6d2c9e1e1fab7e20be627927604621618cfcfbe3289a1acf7ed7c0e465b64a696f02f3a95eac0aaafd1fe9d5431efe7b5 + checksum: 10c0/29dbafc1f02e1167e6d1e92908de6bf7df1cc1fc9ae1de3f4d4abf5d2b537be16b173bcd05770270529eb2fd17a3ac63c2f40d308f7fbbf6d6f286ba564afd64 languageName: node linkType: hard -"@typescript-eslint/parser@npm:8.32.0": - version: 8.32.0 - resolution: "@typescript-eslint/parser@npm:8.32.0" +"@typescript-eslint/parser@npm:8.32.1": + version: 8.32.1 + resolution: "@typescript-eslint/parser@npm:8.32.1" dependencies: - "@typescript-eslint/scope-manager": "npm:8.32.0" - "@typescript-eslint/types": "npm:8.32.0" - "@typescript-eslint/typescript-estree": "npm:8.32.0" - "@typescript-eslint/visitor-keys": "npm:8.32.0" + "@typescript-eslint/scope-manager": "npm:8.32.1" + "@typescript-eslint/types": "npm:8.32.1" + "@typescript-eslint/typescript-estree": "npm:8.32.1" + "@typescript-eslint/visitor-keys": "npm:8.32.1" debug: "npm:^4.3.4" peerDependencies: eslint: ^8.57.0 || ^9.0.0 typescript: ">=4.8.4 <5.9.0" - checksum: 10c0/357a30a853102b1d09a064451f0e66610d41b86f0f4f7bf8b3ce96180e8c58acb0ed24b9f5bba970f7d8d5e94e98c583f2a821135002e3037b0dbce249563926 + checksum: 10c0/01095f5b6e0a2e0631623be3f44be0f2960ceb24de33b64cb790e24a1468018d2b4d6874d1fa08a4928c2a02f208dd66cbc49735c7e8b54d564e420daabf84d1 languageName: node linkType: hard -"@typescript-eslint/scope-manager@npm:8.32.0": - version: 8.32.0 - resolution: "@typescript-eslint/scope-manager@npm:8.32.0" +"@typescript-eslint/scope-manager@npm:8.32.1": + version: 8.32.1 + resolution: "@typescript-eslint/scope-manager@npm:8.32.1" dependencies: - "@typescript-eslint/types": "npm:8.32.0" - "@typescript-eslint/visitor-keys": "npm:8.32.0" - checksum: 10c0/9149d4eebfc7f096a3401a4865e0e552231c91cee362fe3a59c31cf2f0b6b325619f534aed41688c3702867cf86b12454e00055d09e7f229c92083e28e97baac + "@typescript-eslint/types": "npm:8.32.1" + "@typescript-eslint/visitor-keys": "npm:8.32.1" + checksum: 10c0/d2cb1f7736388972137d6e510b2beae4bac033fcab274e04de90ebba3ce466c71fe47f1795357e032e4a6c8b2162016b51b58210916c37212242c82d35352e9f languageName: node linkType: hard -"@typescript-eslint/type-utils@npm:8.32.0": - version: 8.32.0 - resolution: "@typescript-eslint/type-utils@npm:8.32.0" +"@typescript-eslint/type-utils@npm:8.32.1": + version: 8.32.1 + resolution: "@typescript-eslint/type-utils@npm:8.32.1" dependencies: - "@typescript-eslint/typescript-estree": "npm:8.32.0" - "@typescript-eslint/utils": "npm:8.32.0" + "@typescript-eslint/typescript-estree": "npm:8.32.1" + "@typescript-eslint/utils": "npm:8.32.1" debug: "npm:^4.3.4" ts-api-utils: "npm:^2.1.0" peerDependencies: eslint: ^8.57.0 || ^9.0.0 typescript: ">=4.8.4 <5.9.0" - checksum: 10c0/3aec7fbe77d8dae698f75d55d6bed537e7dfa3ed069fbcae456dcf5580c16746ef3e7020522223ca560a75842183fbb8e7ff309e872035d14bf98eb8fae454b4 + checksum: 10c0/f10186340ce194681804d9a57feb6d8d6c3adbd059c70df58f4656b0d9efd412fb0c2d80c182f9db83bad1a301754e0c24fe26f3354bef3a1795ab9c835cb763 languageName: node linkType: hard -"@typescript-eslint/types@npm:8.32.0": - version: 8.32.0 - resolution: "@typescript-eslint/types@npm:8.32.0" - checksum: 10c0/86cc1e365bc12b8baf539e8e2d280b068a7d4a4220f5834fe4de182827a971200408a1ad20f9679af4c4bcdafea03dd66319fe7f1d060ce4b5abbf2962ea3062 +"@typescript-eslint/types@npm:8.32.1": + version: 8.32.1 + resolution: "@typescript-eslint/types@npm:8.32.1" + checksum: 10c0/86f59b29c12e7e8abe45a1659b6fae5e7b0cfaf09ab86dd596ed9d468aa61082bbccd509d25f769b197fbfdf872bbef0b323a2ded6ceaca351f7c679f1ba3bd3 languageName: node linkType: hard -"@typescript-eslint/typescript-estree@npm:8.32.0": - version: 8.32.0 - resolution: "@typescript-eslint/typescript-estree@npm:8.32.0" +"@typescript-eslint/typescript-estree@npm:8.32.1": + version: 8.32.1 + resolution: "@typescript-eslint/typescript-estree@npm:8.32.1" dependencies: - "@typescript-eslint/types": "npm:8.32.0" - "@typescript-eslint/visitor-keys": "npm:8.32.0" + "@typescript-eslint/types": "npm:8.32.1" + "@typescript-eslint/visitor-keys": "npm:8.32.1" debug: "npm:^4.3.4" fast-glob: "npm:^3.3.2" is-glob: "npm:^4.0.3" @@ -1779,32 +1582,32 @@ __metadata: ts-api-utils: "npm:^2.1.0" peerDependencies: typescript: ">=4.8.4 <5.9.0" - checksum: 10c0/c366a457b544c52cb26ffe3e07ed9d3c6eea9fa8a181c2fdba9a0d2076e5d3198dedfb8510038b0791bd338773d8c8d2af048b7c69999d3fd8540ef790dbc720 + checksum: 10c0/b5ae0d91ef1b46c9f3852741e26b7a14c28bb58ee8a283b9530ac484332ca58a7216b9d22eda23c5449b5fd69c6e4601ef3ebbd68e746816ae78269036c08cda languageName: node linkType: hard -"@typescript-eslint/utils@npm:8.32.0": - version: 8.32.0 - resolution: "@typescript-eslint/utils@npm:8.32.0" +"@typescript-eslint/utils@npm:8.32.1": + version: 8.32.1 + resolution: "@typescript-eslint/utils@npm:8.32.1" dependencies: "@eslint-community/eslint-utils": "npm:^4.7.0" - "@typescript-eslint/scope-manager": "npm:8.32.0" - "@typescript-eslint/types": "npm:8.32.0" - "@typescript-eslint/typescript-estree": "npm:8.32.0" + "@typescript-eslint/scope-manager": "npm:8.32.1" + "@typescript-eslint/types": "npm:8.32.1" + "@typescript-eslint/typescript-estree": "npm:8.32.1" peerDependencies: eslint: ^8.57.0 || ^9.0.0 typescript: ">=4.8.4 <5.9.0" - checksum: 10c0/b5b65555b98c8fc92ec016ce2329f644b4d09def28c36422ce77aad9eda1b4dae009bf97b684357e97dd15de66dddba7d8d86e426e11123dae80f7ca2b4f9bd4 + checksum: 10c0/a2b90c0417cd3a33c6e22f9cc28c356f251bb8928ef1d25e057feda007d522d281bdc37a9a0d05b70312f00a7b3f350ca06e724867025ea85bba5a4c766732e7 languageName: node linkType: hard -"@typescript-eslint/visitor-keys@npm:8.32.0": - version: 8.32.0 - resolution: "@typescript-eslint/visitor-keys@npm:8.32.0" +"@typescript-eslint/visitor-keys@npm:8.32.1": + version: 8.32.1 + resolution: "@typescript-eslint/visitor-keys@npm:8.32.1" dependencies: - "@typescript-eslint/types": "npm:8.32.0" + "@typescript-eslint/types": "npm:8.32.1" eslint-visitor-keys: "npm:^4.2.0" - checksum: 10c0/f2e5254d9b1d00cd6360e27240ad72fbab7bcbaed46944943ff077e12fe4883790571f3734f8cb12c3e278bfd7bc4f8f7192ed899f341c282269a9dd16f0cba0 + checksum: 10c0/9c05053dfd048f681eb96e09ceefa8841a617b8b5950eea05e0844b38fe3510a284eb936324caa899c3ceb4bc23efe56ac01437fab378ac1beeb1c6c00404978 languageName: node linkType: hard @@ -1823,10 +1626,10 @@ __metadata: "@preact/preset-vite": "npm:^2.10.1" "@table-library/react-table-library": "npm:4.1.15" "@trivago/prettier-plugin-sort-imports": "npm:^5.2.2" - "@types/node": "npm:^22.15.17" - "@types/react": "npm:^19.1.3" - "@types/react-dom": "npm:^19.1.3" - alova: "npm:3.2.10" + "@types/node": "npm:^22.15.18" + "@types/react": "npm:^19.1.4" + "@types/react-dom": "npm:^19.1.5" + alova: "npm:3.2.11" async-validator: "npm:^4.2.5" concurrently: "npm:^9.1.2" eslint: "npm:^9.26.0" @@ -1843,10 +1646,10 @@ __metadata: react-router: "npm:^7.6.0" react-toastify: "npm:^11.0.5" rollup-plugin-visualizer: "npm:^5.14.0" - terser: "npm:^5.39.0" + terser: "npm:^5.39.2" typesafe-i18n: "npm:^5.26.2" typescript: "npm:^5.8.3" - typescript-eslint: "npm:8.32.0" + typescript-eslint: "npm:8.32.1" vite: "npm:^6.3.5" vite-plugin-imagemin: "npm:^0.6.1" vite-tsconfig-paths: "npm:^5.1.4" @@ -1879,7 +1682,7 @@ __metadata: languageName: node linkType: hard -"acorn@npm:^8.14.0, acorn@npm:^8.8.2": +"acorn@npm:^8.14.0": version: 8.14.1 resolution: "acorn@npm:8.14.1" bin: @@ -1907,13 +1710,13 @@ __metadata: languageName: node linkType: hard -"alova@npm:3.2.10": - version: 3.2.10 - resolution: "alova@npm:3.2.10" +"alova@npm:3.2.11": + version: 3.2.11 + resolution: "alova@npm:3.2.11" dependencies: "@alova/shared": "npm:1.1.2" rate-limiter-flexible: "npm:^5.0.3" - checksum: 10c0/c559252ee8544c4cb286386b3d641bdb1105d69c183d214df99934a5c93185fc6da512198e9258bc6fcdd78af327a1100cb66f2bb1f1b617ee056b0aa57c5286 + checksum: 10c0/d024b56297e05f9ee2f7cf175abea7e4f4bd8feeb9a7242e22f58ca01b901df219e5725def499935178945f62e6ab06070d8c8c23b0d52396921400e496ac991 languageName: node linkType: hard @@ -2167,16 +1970,16 @@ __metadata: linkType: hard "browserslist@npm:^4.24.0": - version: 4.24.4 - resolution: "browserslist@npm:4.24.4" + version: 4.24.5 + resolution: "browserslist@npm:4.24.5" dependencies: - caniuse-lite: "npm:^1.0.30001688" - electron-to-chromium: "npm:^1.5.73" + caniuse-lite: "npm:^1.0.30001716" + electron-to-chromium: "npm:^1.5.149" node-releases: "npm:^2.0.19" - update-browserslist-db: "npm:^1.1.1" + update-browserslist-db: "npm:^1.1.3" bin: browserslist: cli.js - checksum: 10c0/db7ebc1733cf471e0b490b4f47e3e2ea2947ce417192c9246644e92c667dd56a71406cc58f62ca7587caf828364892e9952904a02b7aead752bc65b62a37cfe9 + checksum: 10c0/f4c1ce1a7d8fdfab5e5b88bb6e93d09e8a883c393f86801537a252da0362dbdcde4dbd97b318246c5d84c6607b2f6b47af732c1b000d6a8a881ee024bad29204 languageName: node linkType: hard @@ -2314,10 +2117,10 @@ __metadata: languageName: node linkType: hard -"caniuse-lite@npm:^1.0.30001688": - version: 1.0.30001715 - resolution: "caniuse-lite@npm:1.0.30001715" - checksum: 10c0/0109a7da797ffbe1aa197baa5242b205011098eecec1087ef3d0c58ceea19be325ab6679b2751a78660adc3051a9f77e99d5789938fd1eb1235e6fdf6a1dbf8e +"caniuse-lite@npm:^1.0.30001716": + version: 1.0.30001718 + resolution: "caniuse-lite@npm:1.0.30001718" + checksum: 10c0/67f9ad09bc16443e28d14f265d6e468480cd8dc1900d0d8b982222de80c699c4f2306599c3da8a3fa7139f110d4b30d49dbac78f215470f479abb6ffe141d5d3 languageName: node linkType: hard @@ -2583,7 +2386,7 @@ __metadata: languageName: node linkType: hard -"cross-spawn@npm:^7.0.0, cross-spawn@npm:^7.0.3, cross-spawn@npm:^7.0.6": +"cross-spawn@npm:^7.0.0, cross-spawn@npm:^7.0.3, cross-spawn@npm:^7.0.5, cross-spawn@npm:^7.0.6": version: 7.0.6 resolution: "cross-spawn@npm:7.0.6" dependencies: @@ -2675,14 +2478,14 @@ __metadata: linkType: hard "debug@npm:4, debug@npm:^4.1.0, debug@npm:^4.1.1, debug@npm:^4.3.1, debug@npm:^4.3.2, debug@npm:^4.3.3, debug@npm:^4.3.4, debug@npm:^4.3.5, debug@npm:^4.4.0": - version: 4.4.0 - resolution: "debug@npm:4.4.0" + version: 4.4.1 + resolution: "debug@npm:4.4.1" dependencies: ms: "npm:^2.1.3" peerDependenciesMeta: supports-color: optional: true - checksum: 10c0/db94f1a182bf886f57b4755f85b3a74c39b5114b9377b7ab375dc2cfa3454f09490cc6c30f829df3fc8042bc8b8995f6567ce5cd96f3bc3688bd24027197d9de + checksum: 10c0/d2b44bc1afd912b49bb7ebb0d50a860dc93a4dd7d946e8de94abc957bb63726b7dd5aa48c18c2386c379ec024c46692e15ed3ed97d481729f929201e671fcd55 languageName: node linkType: hard @@ -2962,10 +2765,10 @@ __metadata: languageName: node linkType: hard -"electron-to-chromium@npm:^1.5.73": - version: 1.5.142 - resolution: "electron-to-chromium@npm:1.5.142" - checksum: 10c0/05bc0c695a4b7c6fac499700199bfd90d767eea352e67171f005920a225e42fa08dc62ba0d31523fcd2e9b49e25aab133f82270e784888fb5c3c032f6607cdeb +"electron-to-chromium@npm:^1.5.149": + version: 1.5.155 + resolution: "electron-to-chromium@npm:1.5.155" + checksum: 10c0/aee32a0b03282e488352370f6a910de37788b814031020a0e244943450e844e8a41f741d6e5ec70d553dfa4382ef80088034ddc400b48f45de95de331b9ec178 languageName: node linkType: hard @@ -3283,34 +3086,34 @@ __metadata: linkType: hard "esbuild@npm:^0.25.0": - version: 0.25.3 - resolution: "esbuild@npm:0.25.3" + version: 0.25.4 + resolution: "esbuild@npm:0.25.4" dependencies: - "@esbuild/aix-ppc64": "npm:0.25.3" - "@esbuild/android-arm": "npm:0.25.3" - "@esbuild/android-arm64": "npm:0.25.3" - "@esbuild/android-x64": "npm:0.25.3" - "@esbuild/darwin-arm64": "npm:0.25.3" - "@esbuild/darwin-x64": "npm:0.25.3" - "@esbuild/freebsd-arm64": "npm:0.25.3" - "@esbuild/freebsd-x64": "npm:0.25.3" - "@esbuild/linux-arm": "npm:0.25.3" - "@esbuild/linux-arm64": "npm:0.25.3" - "@esbuild/linux-ia32": "npm:0.25.3" - "@esbuild/linux-loong64": "npm:0.25.3" - "@esbuild/linux-mips64el": "npm:0.25.3" - "@esbuild/linux-ppc64": "npm:0.25.3" - "@esbuild/linux-riscv64": "npm:0.25.3" - "@esbuild/linux-s390x": "npm:0.25.3" - "@esbuild/linux-x64": "npm:0.25.3" - "@esbuild/netbsd-arm64": "npm:0.25.3" - "@esbuild/netbsd-x64": "npm:0.25.3" - "@esbuild/openbsd-arm64": "npm:0.25.3" - "@esbuild/openbsd-x64": "npm:0.25.3" - "@esbuild/sunos-x64": "npm:0.25.3" - "@esbuild/win32-arm64": "npm:0.25.3" - "@esbuild/win32-ia32": "npm:0.25.3" - "@esbuild/win32-x64": "npm:0.25.3" + "@esbuild/aix-ppc64": "npm:0.25.4" + "@esbuild/android-arm": "npm:0.25.4" + "@esbuild/android-arm64": "npm:0.25.4" + "@esbuild/android-x64": "npm:0.25.4" + "@esbuild/darwin-arm64": "npm:0.25.4" + "@esbuild/darwin-x64": "npm:0.25.4" + "@esbuild/freebsd-arm64": "npm:0.25.4" + "@esbuild/freebsd-x64": "npm:0.25.4" + "@esbuild/linux-arm": "npm:0.25.4" + "@esbuild/linux-arm64": "npm:0.25.4" + "@esbuild/linux-ia32": "npm:0.25.4" + "@esbuild/linux-loong64": "npm:0.25.4" + "@esbuild/linux-mips64el": "npm:0.25.4" + "@esbuild/linux-ppc64": "npm:0.25.4" + "@esbuild/linux-riscv64": "npm:0.25.4" + "@esbuild/linux-s390x": "npm:0.25.4" + "@esbuild/linux-x64": "npm:0.25.4" + "@esbuild/netbsd-arm64": "npm:0.25.4" + "@esbuild/netbsd-x64": "npm:0.25.4" + "@esbuild/openbsd-arm64": "npm:0.25.4" + "@esbuild/openbsd-x64": "npm:0.25.4" + "@esbuild/sunos-x64": "npm:0.25.4" + "@esbuild/win32-arm64": "npm:0.25.4" + "@esbuild/win32-ia32": "npm:0.25.4" + "@esbuild/win32-x64": "npm:0.25.4" dependenciesMeta: "@esbuild/aix-ppc64": optional: true @@ -3364,7 +3167,7 @@ __metadata: optional: true bin: esbuild: bin/esbuild - checksum: 10c0/127aff654310ede4e2eb232a7b1d8823f5b5d69222caf17aa7f172574a5b6b75f71ce78c6d8a40030421d7c75b784dc640de0fb1b87b7ea77ab2a1c832fa8df8 + checksum: 10c0/db9f51248f0560bc46ab219461d338047617f6caf373c95f643b204760bdfa10c95b48cfde948949f7e509599ae4ab61c3f112092a3534936c6abfb800c565b0 languageName: node linkType: hard @@ -3541,18 +3344,18 @@ __metadata: linkType: hard "eventsource-parser@npm:^3.0.1": - version: 3.0.1 - resolution: "eventsource-parser@npm:3.0.1" - checksum: 10c0/146ce5ae8325d07645a49bbc54d7ac3aef42f5138bfbbe83d5cf96293b50eab2219926d6cf41eed0a0f90132578089652ba9286a19297662900133a9da6c2fd0 + version: 3.0.2 + resolution: "eventsource-parser@npm:3.0.2" + checksum: 10c0/067c6e60b7c68a4577630cc7e11d2aaeef52005e377a213308c7c2350596a175d5a179671d85f570726dce3f451c15d174ece4479ce68a1805686c88950d08dd languageName: node linkType: hard "eventsource@npm:^3.0.2": - version: 3.0.6 - resolution: "eventsource@npm:3.0.6" + version: 3.0.7 + resolution: "eventsource@npm:3.0.7" dependencies: eventsource-parser: "npm:^3.0.1" - checksum: 10c0/074d865ea1c7e29e3243f85a13306e89fca2d775b982dca03fa6bfa75c56827fa89cf1ab9e730db24bd6b104cbdcae074f2b37ba498874e9dd9710fbff4979bb + checksum: 10c0/c48a73c38f300e33e9f11375d4ee969f25cbb0519608a12378a38068055ae8b55b6e0e8a49c3f91c784068434efe1d9f01eb49b6315b04b0da9157879ce2f67d languageName: node linkType: hard @@ -4415,9 +4218,9 @@ __metadata: linkType: hard "http-cache-semantics@npm:^4.1.1": - version: 4.1.1 - resolution: "http-cache-semantics@npm:4.1.1" - checksum: 10c0/ce1319b8a382eb3cbb4a37c19f6bfe14e5bb5be3d09079e885e8c513ab2d3cd9214902f8a31c9dc4e37022633ceabfc2d697405deeaf1b8f3552bb4ed996fdfc + version: 4.2.0 + resolution: "http-cache-semantics@npm:4.2.0" + checksum: 10c0/45b66a945cf13ec2d1f29432277201313babf4a01d9e52f44b31ca923434083afeca03f18417f599c9ab3d0e7b618ceb21257542338b57c54b710463b4a53e37 languageName: node linkType: hard @@ -4484,13 +4287,20 @@ __metadata: languageName: node linkType: hard -"ignore@npm:^5.1.1, ignore@npm:^5.2.0, ignore@npm:^5.3.1": +"ignore@npm:^5.1.1, ignore@npm:^5.2.0": version: 5.3.2 resolution: "ignore@npm:5.3.2" checksum: 10c0/f9f652c957983634ded1e7f02da3b559a0d4cc210fca3792cb67f1b153623c9c42efdc1c4121af171e295444459fc4a9201101fb041b1104a3c000bccb188337 languageName: node linkType: hard +"ignore@npm:^7.0.0": + version: 7.0.4 + resolution: "ignore@npm:7.0.4" + checksum: 10c0/90e1f69ce352b9555caecd9cbfd07abe7626d312a6f90efbbb52c7edca6ea8df065d66303863b30154ab1502afb2da8bc59d5b04e1719a52ef75bbf675c488eb + languageName: node + linkType: hard + "imagemin-gifsicle@npm:^7.0.0": version: 7.0.0 resolution: "imagemin-gifsicle@npm:7.0.0" @@ -6367,13 +6177,6 @@ __metadata: languageName: node linkType: hard -"regenerator-runtime@npm:^0.14.0": - version: 0.14.1 - resolution: "regenerator-runtime@npm:0.14.1" - checksum: 10c0/1b16eb2c4bceb1665c89de70dcb64126a22bc8eb958feef3cd68fe11ac6d2a4899b5cd1b80b0774c7c03591dc57d16631a7f69d2daa2ec98100e2f29f7ec4cc4 - languageName: node - linkType: hard - "repeating@npm:^2.0.0": version: 2.0.1 resolution: "repeating@npm:2.0.1" @@ -6487,29 +6290,29 @@ __metadata: linkType: hard "rollup@npm:^4.34.9": - version: 4.40.0 - resolution: "rollup@npm:4.40.0" + version: 4.40.2 + resolution: "rollup@npm:4.40.2" dependencies: - "@rollup/rollup-android-arm-eabi": "npm:4.40.0" - "@rollup/rollup-android-arm64": "npm:4.40.0" - "@rollup/rollup-darwin-arm64": "npm:4.40.0" - "@rollup/rollup-darwin-x64": "npm:4.40.0" - "@rollup/rollup-freebsd-arm64": "npm:4.40.0" - "@rollup/rollup-freebsd-x64": "npm:4.40.0" - "@rollup/rollup-linux-arm-gnueabihf": "npm:4.40.0" - "@rollup/rollup-linux-arm-musleabihf": "npm:4.40.0" - "@rollup/rollup-linux-arm64-gnu": "npm:4.40.0" - "@rollup/rollup-linux-arm64-musl": "npm:4.40.0" - "@rollup/rollup-linux-loongarch64-gnu": "npm:4.40.0" - "@rollup/rollup-linux-powerpc64le-gnu": "npm:4.40.0" - "@rollup/rollup-linux-riscv64-gnu": "npm:4.40.0" - "@rollup/rollup-linux-riscv64-musl": "npm:4.40.0" - "@rollup/rollup-linux-s390x-gnu": "npm:4.40.0" - "@rollup/rollup-linux-x64-gnu": "npm:4.40.0" - "@rollup/rollup-linux-x64-musl": "npm:4.40.0" - "@rollup/rollup-win32-arm64-msvc": "npm:4.40.0" - "@rollup/rollup-win32-ia32-msvc": "npm:4.40.0" - "@rollup/rollup-win32-x64-msvc": "npm:4.40.0" + "@rollup/rollup-android-arm-eabi": "npm:4.40.2" + "@rollup/rollup-android-arm64": "npm:4.40.2" + "@rollup/rollup-darwin-arm64": "npm:4.40.2" + "@rollup/rollup-darwin-x64": "npm:4.40.2" + "@rollup/rollup-freebsd-arm64": "npm:4.40.2" + "@rollup/rollup-freebsd-x64": "npm:4.40.2" + "@rollup/rollup-linux-arm-gnueabihf": "npm:4.40.2" + "@rollup/rollup-linux-arm-musleabihf": "npm:4.40.2" + "@rollup/rollup-linux-arm64-gnu": "npm:4.40.2" + "@rollup/rollup-linux-arm64-musl": "npm:4.40.2" + "@rollup/rollup-linux-loongarch64-gnu": "npm:4.40.2" + "@rollup/rollup-linux-powerpc64le-gnu": "npm:4.40.2" + "@rollup/rollup-linux-riscv64-gnu": "npm:4.40.2" + "@rollup/rollup-linux-riscv64-musl": "npm:4.40.2" + "@rollup/rollup-linux-s390x-gnu": "npm:4.40.2" + "@rollup/rollup-linux-x64-gnu": "npm:4.40.2" + "@rollup/rollup-linux-x64-musl": "npm:4.40.2" + "@rollup/rollup-win32-arm64-msvc": "npm:4.40.2" + "@rollup/rollup-win32-ia32-msvc": "npm:4.40.2" + "@rollup/rollup-win32-x64-msvc": "npm:4.40.2" "@types/estree": "npm:1.0.7" fsevents: "npm:~2.3.2" dependenciesMeta: @@ -6557,7 +6360,7 @@ __metadata: optional: true bin: rollup: dist/bin/rollup - checksum: 10c0/90aa57487d4a9a7de1a47bf42a6091f83f1cb7fe1814650dfec278ab8ddae5736b86535d4c766493517720f334dfd4aa0635405ca8f4f36ed8d3c0f875f2a801 + checksum: 10c0/cbe9b766891da74fbf7c3b50420bb75102e5c59afc0ea45751f7e43a581d2cd93367763f521f820b72e341cf1f6b9951fbdcd3be67a1b0aa774b754525a8b9c7 languageName: node linkType: hard @@ -6667,11 +6470,11 @@ __metadata: linkType: hard "semver@npm:^7.3.5, semver@npm:^7.6.0": - version: 7.7.1 - resolution: "semver@npm:7.7.1" + version: 7.7.2 + resolution: "semver@npm:7.7.2" bin: semver: bin/semver.js - checksum: 10c0/fd603a6fb9c399c6054015433051bdbe7b99a940a8fb44b85c2b524c4004b023d7928d47cb22154f8d054ea7ee8597f586605e05b52047f048278e4ac56ae958 + checksum: 10c0/aca305edfbf2383c22571cb7714f48cadc7ac95371b4b52362fb8eeffdfbc0de0669368b82b2b15978f8848f01d7114da65697e56cd8c37b0dab8c58e543f9ea languageName: node linkType: hard @@ -7245,17 +7048,17 @@ __metadata: languageName: node linkType: hard -"terser@npm:^5.39.0": - version: 5.39.0 - resolution: "terser@npm:5.39.0" +"terser@npm:^5.39.2": + version: 5.39.2 + resolution: "terser@npm:5.39.2" dependencies: "@jridgewell/source-map": "npm:^0.3.3" - acorn: "npm:^8.8.2" + acorn: "npm:^8.14.0" commander: "npm:^2.20.0" source-map-support: "npm:~0.5.20" bin: terser: bin/terser - checksum: 10c0/83326545ea1aecd6261030568b6191ccfa4cb6aa61d9ea41746a52479f50017a78b77e4725fbbc207c5df841ffa66a773c5ac33636e95c7ab94fe7e0379ae5c7 + checksum: 10c0/f70462feddecf458ad2441b16b2969e0024f81c6e47207717a096cfa1d60b85e0c60a129b42c80bcb258c28ae16e4e6d875db8bb9df9be9b5bc748807c2916ba languageName: node linkType: hard @@ -7408,17 +7211,17 @@ __metadata: languageName: node linkType: hard -"typescript-eslint@npm:8.32.0": - version: 8.32.0 - resolution: "typescript-eslint@npm:8.32.0" +"typescript-eslint@npm:8.32.1": + version: 8.32.1 + resolution: "typescript-eslint@npm:8.32.1" dependencies: - "@typescript-eslint/eslint-plugin": "npm:8.32.0" - "@typescript-eslint/parser": "npm:8.32.0" - "@typescript-eslint/utils": "npm:8.32.0" + "@typescript-eslint/eslint-plugin": "npm:8.32.1" + "@typescript-eslint/parser": "npm:8.32.1" + "@typescript-eslint/utils": "npm:8.32.1" peerDependencies: eslint: ^8.57.0 || ^9.0.0 typescript: ">=4.8.4 <5.9.0" - checksum: 10c0/f74c2a3defec95f5f6d0887a9c57ad4f38d62fabe4e4a5a83bf6e198832efb6d706d08c89002f7765c3438e41f4c71d4a4694918056aa3a50b7b786569298fe4 + checksum: 10c0/15602916b582b86c8b4371e99d5721c92af7ae56f9b49cd7971d2a49f11bf0bd64dd8d2c0e2b3ca87b2f3a6fd14966738121f3f8299de50c6109b9f245397f3b languageName: node linkType: hard @@ -7491,7 +7294,7 @@ __metadata: languageName: node linkType: hard -"update-browserslist-db@npm:^1.1.1": +"update-browserslist-db@npm:^1.1.3": version: 1.1.3 resolution: "update-browserslist-db@npm:1.1.3" dependencies: diff --git a/mock-api/yarn.lock b/mock-api/yarn.lock index a37814230..0c05aebdc 100644 --- a/mock-api/yarn.lock +++ b/mock-api/yarn.lock @@ -5,88 +5,88 @@ __metadata: version: 8 cacheKey: 10c0 -"@babel/code-frame@npm:^7.26.2": - version: 7.26.2 - resolution: "@babel/code-frame@npm:7.26.2" +"@babel/code-frame@npm:^7.27.1": + version: 7.27.1 + resolution: "@babel/code-frame@npm:7.27.1" dependencies: - "@babel/helper-validator-identifier": "npm:^7.25.9" + "@babel/helper-validator-identifier": "npm:^7.27.1" js-tokens: "npm:^4.0.0" - picocolors: "npm:^1.0.0" - checksum: 10c0/7d79621a6849183c415486af99b1a20b84737e8c11cd55b6544f688c51ce1fd710e6d869c3dd21232023da272a79b91efb3e83b5bc2dc65c1187c5fcd1b72ea8 + picocolors: "npm:^1.1.1" + checksum: 10c0/5dd9a18baa5fce4741ba729acc3a3272c49c25cb8736c4b18e113099520e7ef7b545a4096a26d600e4416157e63e87d66db46aa3fbf0a5f2286da2705c12da00 languageName: node linkType: hard -"@babel/generator@npm:^7.26.5, @babel/generator@npm:^7.27.0": - version: 7.27.0 - resolution: "@babel/generator@npm:7.27.0" +"@babel/generator@npm:^7.26.5, @babel/generator@npm:^7.27.1": + version: 7.27.1 + resolution: "@babel/generator@npm:7.27.1" dependencies: - "@babel/parser": "npm:^7.27.0" - "@babel/types": "npm:^7.27.0" + "@babel/parser": "npm:^7.27.1" + "@babel/types": "npm:^7.27.1" "@jridgewell/gen-mapping": "npm:^0.3.5" "@jridgewell/trace-mapping": "npm:^0.3.25" jsesc: "npm:^3.0.2" - checksum: 10c0/7cb10693d2b365c278f109a745dc08856cae139d262748b77b70ce1d97da84627f79648cab6940d847392c0e5d180441669ed958b3aee98d9c7d274b37c553bd + checksum: 10c0/c4156434b21818f558ebd93ce45f027c53ee570ce55a84fd2d9ba45a79ad204c17e0bff753c886fb6c07df3385445a9e34dc7ccb070d0ac7e80bb91c8b57f423 languageName: node linkType: hard -"@babel/helper-string-parser@npm:^7.25.9": - version: 7.25.9 - resolution: "@babel/helper-string-parser@npm:7.25.9" - checksum: 10c0/7244b45d8e65f6b4338a6a68a8556f2cb161b782343e97281a5f2b9b93e420cad0d9f5773a59d79f61d0c448913d06f6a2358a87f2e203cf112e3c5b53522ee6 +"@babel/helper-string-parser@npm:^7.27.1": + version: 7.27.1 + resolution: "@babel/helper-string-parser@npm:7.27.1" + checksum: 10c0/8bda3448e07b5583727c103560bcf9c4c24b3c1051a4c516d4050ef69df37bb9a4734a585fe12725b8c2763de0a265aa1e909b485a4e3270b7cfd3e4dbe4b602 languageName: node linkType: hard -"@babel/helper-validator-identifier@npm:^7.25.9": - version: 7.25.9 - resolution: "@babel/helper-validator-identifier@npm:7.25.9" - checksum: 10c0/4fc6f830177b7b7e887ad3277ddb3b91d81e6c4a24151540d9d1023e8dc6b1c0505f0f0628ae653601eb4388a8db45c1c14b2c07a9173837aef7e4116456259d +"@babel/helper-validator-identifier@npm:^7.27.1": + version: 7.27.1 + resolution: "@babel/helper-validator-identifier@npm:7.27.1" + checksum: 10c0/c558f11c4871d526498e49d07a84752d1800bf72ac0d3dad100309a2eaba24efbf56ea59af5137ff15e3a00280ebe588560534b0e894a4750f8b1411d8f78b84 languageName: node linkType: hard -"@babel/parser@npm:^7.26.7, @babel/parser@npm:^7.27.0": - version: 7.27.0 - resolution: "@babel/parser@npm:7.27.0" +"@babel/parser@npm:^7.26.7, @babel/parser@npm:^7.27.1, @babel/parser@npm:^7.27.2": + version: 7.27.2 + resolution: "@babel/parser@npm:7.27.2" dependencies: - "@babel/types": "npm:^7.27.0" + "@babel/types": "npm:^7.27.1" bin: parser: ./bin/babel-parser.js - checksum: 10c0/ba2ed3f41735826546a3ef2a7634a8d10351df221891906e59b29b0a0cd748f9b0e7a6f07576858a9de8e77785aad925c8389ddef146de04ea2842047c9d2859 + checksum: 10c0/3c06692768885c2f58207fc8c2cbdb4a44df46b7d93135a083f6eaa49310f7ced490ce76043a2a7606cdcc13f27e3d835e141b692f2f6337a2e7f43c1dbb04b4 languageName: node linkType: hard -"@babel/template@npm:^7.27.0": - version: 7.27.0 - resolution: "@babel/template@npm:7.27.0" +"@babel/template@npm:^7.27.1": + version: 7.27.2 + resolution: "@babel/template@npm:7.27.2" dependencies: - "@babel/code-frame": "npm:^7.26.2" - "@babel/parser": "npm:^7.27.0" - "@babel/types": "npm:^7.27.0" - checksum: 10c0/13af543756127edb5f62bf121f9b093c09a2b6fe108373887ccffc701465cfbcb17e07cf48aa7f440415b263f6ec006e9415c79dfc2e8e6010b069435f81f340 + "@babel/code-frame": "npm:^7.27.1" + "@babel/parser": "npm:^7.27.2" + "@babel/types": "npm:^7.27.1" + checksum: 10c0/ed9e9022651e463cc5f2cc21942f0e74544f1754d231add6348ff1b472985a3b3502041c0be62dc99ed2d12cfae0c51394bf827452b98a2f8769c03b87aadc81 languageName: node linkType: hard "@babel/traverse@npm:^7.26.7": - version: 7.27.0 - resolution: "@babel/traverse@npm:7.27.0" + version: 7.27.1 + resolution: "@babel/traverse@npm:7.27.1" dependencies: - "@babel/code-frame": "npm:^7.26.2" - "@babel/generator": "npm:^7.27.0" - "@babel/parser": "npm:^7.27.0" - "@babel/template": "npm:^7.27.0" - "@babel/types": "npm:^7.27.0" + "@babel/code-frame": "npm:^7.27.1" + "@babel/generator": "npm:^7.27.1" + "@babel/parser": "npm:^7.27.1" + "@babel/template": "npm:^7.27.1" + "@babel/types": "npm:^7.27.1" debug: "npm:^4.3.1" globals: "npm:^11.1.0" - checksum: 10c0/c7af29781960dacaae51762e8bc6c4b13d6ab4b17312990fbca9fc38e19c4ad7fecaae24b1cf52fb844e8e6cdc76c70ad597f90e496bcb3cc0a1d66b41a0aa5b + checksum: 10c0/d912110037b03b1d70a2436cfd51316d930366a5f54252da2bced1ba38642f644f848240a951e5caf12f1ef6c40d3d96baa92ea6e84800f2e891c15e97b25d50 languageName: node linkType: hard -"@babel/types@npm:^7.26.7, @babel/types@npm:^7.27.0": - version: 7.27.0 - resolution: "@babel/types@npm:7.27.0" +"@babel/types@npm:^7.26.7, @babel/types@npm:^7.27.1": + version: 7.27.1 + resolution: "@babel/types@npm:7.27.1" dependencies: - "@babel/helper-string-parser": "npm:^7.25.9" - "@babel/helper-validator-identifier": "npm:^7.25.9" - checksum: 10c0/6f1592eabe243c89a608717b07b72969be9d9d2fce1dee21426238757ea1fa60fdfc09b29de9e48d8104311afc6e6fb1702565a9cc1e09bc1e76f2b2ddb0f6e1 + "@babel/helper-string-parser": "npm:^7.27.1" + "@babel/helper-validator-identifier": "npm:^7.27.1" + checksum: 10c0/ed736f14db2fdf0d36c539c8e06b6bb5e8f9649a12b5c0e1c516fed827f27ef35085abe08bf4d1302a4e20c9a254e762eed453bce659786d4a6e01ba26a91377 languageName: node linkType: hard @@ -189,14 +189,14 @@ __metadata: linkType: hard "debug@npm:^4.3.1": - version: 4.4.0 - resolution: "debug@npm:4.4.0" + version: 4.4.1 + resolution: "debug@npm:4.4.1" dependencies: ms: "npm:^2.1.3" peerDependenciesMeta: supports-color: optional: true - checksum: 10c0/db94f1a182bf886f57b4755f85b3a74c39b5114b9377b7ab375dc2cfa3454f09490cc6c30f829df3fc8042bc8b8995f6567ce5cd96f3bc3688bd24027197d9de + checksum: 10c0/d2b44bc1afd912b49bb7ebb0d50a860dc93a4dd7d946e8de94abc957bb63726b7dd5aa48c18c2386c379ec024c46692e15ed3ed97d481729f929201e671fcd55 languageName: node linkType: hard @@ -293,7 +293,7 @@ __metadata: languageName: node linkType: hard -"picocolors@npm:^1.0.0": +"picocolors@npm:^1.1.1": version: 1.1.1 resolution: "picocolors@npm:1.1.1" checksum: 10c0/e2e3e8170ab9d7c7421969adaa7e1b31434f789afb9b3f115f6b96d91945041ac3ceb02e9ec6fe6510ff036bcc0bf91e69a1772edc0b707e12b19c0f2d6bcf58 diff --git a/src/core/modbus_entity_parameters.hpp b/src/core/modbus_entity_parameters.hpp index 3b1e5e2d1..ad5276ee7 100644 --- a/src/core/modbus_entity_parameters.hpp +++ b/src/core/modbus_entity_parameters.hpp @@ -249,13 +249,14 @@ const std::initializer_list Modbus::modbus_register_ma REGISTER_MAPPING(dt::BOILER, TAG_TYPE_DHW, FL_(wwTempOK), 60, 1), // tempok REGISTER_MAPPING(dt::BOILER, TAG_TYPE_DHW, FL_(wwActive), 61, 1), // active REGISTER_MAPPING(dt::BOILER, TAG_TYPE_DHW, FL_(ww3wayValve), 62, 1), // 3wayvalve - REGISTER_MAPPING(dt::BOILER, TAG_TYPE_DHW, FL_(wwMixerTemp), 63, 1), // mixertemp - REGISTER_MAPPING(dt::BOILER, TAG_TYPE_DHW, FL_(cylMiddleTemp), 64, 1), // cylmiddletemp - REGISTER_MAPPING(dt::BOILER, TAG_TYPE_DHW, FL_(wwStarts), 65, 2), // starts - REGISTER_MAPPING(dt::BOILER, TAG_TYPE_DHW, FL_(wwWorkM), 67, 2), // workm - REGISTER_MAPPING(dt::BOILER, TAG_TYPE_DHW, FL_(gasMeterWw), 69, 2), // gasmeter - REGISTER_MAPPING(dt::BOILER, TAG_TYPE_DHW, FL_(nrgWw2), 71, 2), // nrg2 - REGISTER_MAPPING(dt::BOILER, TAG_TYPE_DHW, FL_(wwValve), 73, 1), // dhwvalve + REGISTER_MAPPING(dt::BOILER, TAG_TYPE_DHW, FL_(wwChargePump), 63, 1), // chargepump + REGISTER_MAPPING(dt::BOILER, TAG_TYPE_DHW, FL_(wwMixerTemp), 64, 1), // mixertemp + REGISTER_MAPPING(dt::BOILER, TAG_TYPE_DHW, FL_(cylMiddleTemp), 65, 1), // cylmiddletemp + REGISTER_MAPPING(dt::BOILER, TAG_TYPE_DHW, FL_(wwStarts), 66, 2), // starts + REGISTER_MAPPING(dt::BOILER, TAG_TYPE_DHW, FL_(wwWorkM), 68, 2), // workm + REGISTER_MAPPING(dt::BOILER, TAG_TYPE_DHW, FL_(gasMeterWw), 70, 2), // gasmeter + REGISTER_MAPPING(dt::BOILER, TAG_TYPE_DHW, FL_(nrgWw2), 72, 2), // nrg2 + REGISTER_MAPPING(dt::BOILER, TAG_TYPE_DHW, FL_(wwValve), 74, 1), // dhwvalve REGISTER_MAPPING(dt::THERMOSTAT, TAG_TYPE_DEVICE_DATA, FL_(errorCode), 0, 8), // errorcode REGISTER_MAPPING(dt::THERMOSTAT, TAG_TYPE_DEVICE_DATA, FL_(lastCode), 8, 25), // lastcode REGISTER_MAPPING(dt::THERMOSTAT, TAG_TYPE_DEVICE_DATA, FL_(dateTime), 33, 13), // datetime