update hybrid heatpump #459
This commit is contained in:
@@ -36,7 +36,7 @@
|
|||||||
{132, DeviceType::BOILER, F("GC7000F"), DeviceFlags::EMS_DEVICE_FLAG_NONE},
|
{132, DeviceType::BOILER, F("GC7000F"), DeviceFlags::EMS_DEVICE_FLAG_NONE},
|
||||||
{133, DeviceType::BOILER, F("Logano GB125/KB195i/Logamatic MC110"), DeviceFlags::EMS_DEVICE_FLAG_NONE},
|
{133, DeviceType::BOILER, F("Logano GB125/KB195i/Logamatic MC110"), DeviceFlags::EMS_DEVICE_FLAG_NONE},
|
||||||
{167, DeviceType::BOILER, F("Cerapur Aero"), DeviceFlags::EMS_DEVICE_FLAG_NONE},
|
{167, DeviceType::BOILER, F("Cerapur Aero"), DeviceFlags::EMS_DEVICE_FLAG_NONE},
|
||||||
{168, DeviceType::BOILER, F("Hybrid Heatpump"), DeviceFlags::EMS_DEVICE_FLAG_HEATPUMP},
|
{168, DeviceType::BOILER, F("Hybrid Heatpump"), DeviceFlags::EMS_DEVICE_FLAG_HYBRID},
|
||||||
{170, DeviceType::BOILER, F("Logano GB212"), DeviceFlags::EMS_DEVICE_FLAG_NONE},
|
{170, DeviceType::BOILER, F("Logano GB212"), DeviceFlags::EMS_DEVICE_FLAG_NONE},
|
||||||
{172, DeviceType::BOILER, F("Enviline/Compress 6000AW/Hybrid 7000iAW/SupraEco/Geo 5xx"), DeviceFlags::EMS_DEVICE_FLAG_HEATPUMP},
|
{172, DeviceType::BOILER, F("Enviline/Compress 6000AW/Hybrid 7000iAW/SupraEco/Geo 5xx"), DeviceFlags::EMS_DEVICE_FLAG_HEATPUMP},
|
||||||
{173, DeviceType::BOILER, F("Geo 5xx"), DeviceFlags::EMS_DEVICE_FLAG_HEATPUMP},
|
{173, DeviceType::BOILER, F("Geo 5xx"), DeviceFlags::EMS_DEVICE_FLAG_HEATPUMP},
|
||||||
|
|||||||
@@ -71,7 +71,7 @@ Boiler::Boiler(uint8_t device_type, int8_t device_id, uint8_t product_id, const
|
|||||||
}
|
}
|
||||||
|
|
||||||
// only EMS+
|
// only EMS+
|
||||||
if (model() != EMSdevice::EMS_DEVICE_FLAG_EMS && model() != EMSdevice::EMS_DEVICE_FLAG_HT3) {
|
if (model() != EMSdevice::EMS_DEVICE_FLAG_EMS && model() != EMSdevice::EMS_DEVICE_FLAG_HT3 && model() != EMSdevice::EMS_DEVICE_FLAG_HYBRID) {
|
||||||
register_telegram_type(0xD1, F("UBAOutdoorTemp"), false, MAKE_PF_CB(process_UBAOutdoorTemp));
|
register_telegram_type(0xD1, F("UBAOutdoorTemp"), false, MAKE_PF_CB(process_UBAOutdoorTemp));
|
||||||
register_telegram_type(0xE3, F("UBAMonitorSlowPlus2"), false, MAKE_PF_CB(process_UBAMonitorSlowPlus2));
|
register_telegram_type(0xE3, F("UBAMonitorSlowPlus2"), false, MAKE_PF_CB(process_UBAMonitorSlowPlus2));
|
||||||
register_telegram_type(0xE4, F("UBAMonitorFastPlus"), false, MAKE_PF_CB(process_UBAMonitorFastPlus));
|
register_telegram_type(0xE4, F("UBAMonitorFastPlus"), false, MAKE_PF_CB(process_UBAMonitorFastPlus));
|
||||||
@@ -89,6 +89,10 @@ Boiler::Boiler(uint8_t device_type, int8_t device_id, uint8_t product_id, const
|
|||||||
register_telegram_type(0x48A, F("HpPool"), true, MAKE_PF_CB(process_HpPool));
|
register_telegram_type(0x48A, F("HpPool"), true, MAKE_PF_CB(process_HpPool));
|
||||||
}
|
}
|
||||||
|
|
||||||
|
if (model() == EMSdevice::EMS_DEVICE_FLAG_HYBRID) {
|
||||||
|
register_telegram_type(0xBB, F("HybridHp"), true, MAKE_PF_CB(process_HybridHp));
|
||||||
|
}
|
||||||
|
|
||||||
// reset is a command uses a dummy variable which is always zero, shown as blank, but provides command enum options
|
// reset is a command uses a dummy variable which is always zero, shown as blank, but provides command enum options
|
||||||
register_device_value(DeviceValueTAG::TAG_BOILER_DATA, &reset_, DeviceValueType::CMD, FL_(enum_reset), FL_(reset), DeviceValueUOM::NONE, MAKE_CF_CB(set_reset));
|
register_device_value(DeviceValueTAG::TAG_BOILER_DATA, &reset_, DeviceValueType::CMD, FL_(enum_reset), FL_(reset), DeviceValueUOM::NONE, MAKE_CF_CB(set_reset));
|
||||||
has_update(reset_, 0);
|
has_update(reset_, 0);
|
||||||
@@ -198,6 +202,58 @@ Boiler::Boiler(uint8_t device_type, int8_t device_id, uint8_t product_id, const
|
|||||||
DeviceValueUOM::NONE,
|
DeviceValueUOM::NONE,
|
||||||
MAKE_CF_CB(set_maintenancedate));
|
MAKE_CF_CB(set_maintenancedate));
|
||||||
|
|
||||||
|
// Hybrid Heatpump
|
||||||
|
if (model() == EMSdevice::EMS_DEVICE_FLAG_HYBRID) {
|
||||||
|
register_device_value(DeviceValueTAG::TAG_BOILER_DATA,
|
||||||
|
&gasPriceMode_,
|
||||||
|
DeviceValueType::ENUM,
|
||||||
|
FL_(enum_gasPriceMode),
|
||||||
|
FL_(gasPriceMode),
|
||||||
|
DeviceValueUOM::NONE,
|
||||||
|
MAKE_CF_CB(set_gasPriceMode));
|
||||||
|
register_device_value(DeviceValueTAG::TAG_BOILER_DATA,
|
||||||
|
&switchOverTemp_,
|
||||||
|
DeviceValueType::UINT,
|
||||||
|
nullptr,
|
||||||
|
FL_(switchOverTemp),
|
||||||
|
DeviceValueUOM::DEGREES,
|
||||||
|
MAKE_CF_CB(set_switchOverTemp));
|
||||||
|
register_device_value(DeviceValueTAG::TAG_BOILER_DATA,
|
||||||
|
&gasPriceRatio_,
|
||||||
|
DeviceValueType::UINT,
|
||||||
|
FL_(div10),
|
||||||
|
FL_(gasPriceRatio),
|
||||||
|
DeviceValueUOM::NONE,
|
||||||
|
MAKE_CF_CB(set_gasPriceRatio));
|
||||||
|
register_device_value(DeviceValueTAG::TAG_BOILER_DATA,
|
||||||
|
&fossileFactor_,
|
||||||
|
DeviceValueType::UINT,
|
||||||
|
FL_(div10),
|
||||||
|
FL_(fossileFactor),
|
||||||
|
DeviceValueUOM::NONE,
|
||||||
|
MAKE_CF_CB(set_fossileFactor));
|
||||||
|
register_device_value(DeviceValueTAG::TAG_BOILER_DATA,
|
||||||
|
&electricFactor_,
|
||||||
|
DeviceValueType::UINT,
|
||||||
|
FL_(div10),
|
||||||
|
FL_(electricFactor),
|
||||||
|
DeviceValueUOM::NONE,
|
||||||
|
MAKE_CF_CB(set_electricFactor));
|
||||||
|
register_device_value(DeviceValueTAG::TAG_BOILER_DATA,
|
||||||
|
&waitBoiler_,
|
||||||
|
DeviceValueType::UINT,
|
||||||
|
nullptr,
|
||||||
|
FL_(waitBoiler),
|
||||||
|
DeviceValueUOM::MINUTES,
|
||||||
|
MAKE_CF_CB(set_waitBoiler));
|
||||||
|
register_device_value(DeviceValueTAG::TAG_BOILER_DATA,
|
||||||
|
&tempDiffBoiler_,
|
||||||
|
DeviceValueType::UINT,
|
||||||
|
nullptr,
|
||||||
|
FL_(tempDiffBoiler),
|
||||||
|
DeviceValueUOM::DEGREES_R,
|
||||||
|
MAKE_CF_CB(set_tempDiffBoiler));
|
||||||
|
}
|
||||||
// heatpump info
|
// heatpump info
|
||||||
if (model() == EMS_DEVICE_FLAG_HEATPUMP) {
|
if (model() == EMS_DEVICE_FLAG_HEATPUMP) {
|
||||||
register_device_value(DeviceValueTAG::TAG_BOILER_DATA, &upTimeControl_, DeviceValueType::TIME, FL_(div60), FL_(upTimeControl), DeviceValueUOM::MINUTES);
|
register_device_value(DeviceValueTAG::TAG_BOILER_DATA, &upTimeControl_, DeviceValueType::TIME, FL_(div60), FL_(upTimeControl), DeviceValueUOM::MINUTES);
|
||||||
@@ -994,6 +1050,80 @@ void Boiler::process_UBAMaintenanceData(std::shared_ptr<const Telegram> telegram
|
|||||||
}
|
}
|
||||||
}
|
}
|
||||||
|
|
||||||
|
|
||||||
|
// 0xBB Heatpump optimization
|
||||||
|
// Boiler(0x08) -> Me(0x0B), ?(0xBB), data: 00 00 00 00 00 00 00 00 00 00 00 FF 02 0F 1E 0B 1A 00 14 03
|
||||||
|
void Boiler::process_HybridHp(std::shared_ptr<const Telegram> telegram) {
|
||||||
|
has_enumupdate(telegram, gasPriceMode_, 12, 1); // cost = 2, temperature = 3, mix = 4
|
||||||
|
has_update(telegram, switchOverTemp_, 13); // full degrees
|
||||||
|
has_update(telegram, gasPriceRatio_, 14); // is *10
|
||||||
|
has_update(telegram, fossileFactor_, 15); // is * 10
|
||||||
|
has_update(telegram, electricFactor_, 16); // is * 10
|
||||||
|
has_update(telegram, waitBoiler_, 18); // minutes
|
||||||
|
has_update(telegram, tempDiffBoiler_, 19); // relative degrees
|
||||||
|
}
|
||||||
|
|
||||||
|
/*
|
||||||
|
* Settings
|
||||||
|
*/
|
||||||
|
|
||||||
|
bool Boiler::set_gasPriceMode(const char * value, const int8_t id) {
|
||||||
|
uint8_t v;
|
||||||
|
if (!Helpers::value2enum(value, v, FL_(enum_gasPriceMode))) {
|
||||||
|
return false;
|
||||||
|
}
|
||||||
|
write_command(0xBB, 12, v + 1, 0xBB);
|
||||||
|
return true;
|
||||||
|
}
|
||||||
|
bool Boiler::set_switchOverTemp(const char * value, const int8_t id) {
|
||||||
|
int v;
|
||||||
|
if (!Helpers::value2temperature(value, v)) {
|
||||||
|
return false;
|
||||||
|
}
|
||||||
|
write_command(0xBB, 13, v, 0xBB);
|
||||||
|
return true;
|
||||||
|
}
|
||||||
|
bool Boiler::set_gasPriceRatio(const char * value, const int8_t id) {
|
||||||
|
float v;
|
||||||
|
if (!Helpers::value2float(value, v)) {
|
||||||
|
return false;
|
||||||
|
}
|
||||||
|
write_command(0xBB, 14, (uint8_t)(v * 10), 0xBB);
|
||||||
|
return true;
|
||||||
|
}
|
||||||
|
bool Boiler::set_fossileFactor(const char * value, const int8_t id) {
|
||||||
|
float v;
|
||||||
|
if (!Helpers::value2float(value, v)) {
|
||||||
|
return false;
|
||||||
|
}
|
||||||
|
write_command(0xBB, 15, (uint8_t)(v * 10), 0xBB);
|
||||||
|
return true;
|
||||||
|
}
|
||||||
|
bool Boiler::set_electricFactor(const char * value, const int8_t id) {
|
||||||
|
float v;
|
||||||
|
if (!Helpers::value2float(value, v)) {
|
||||||
|
return false;
|
||||||
|
}
|
||||||
|
write_command(0xBB, 16, (uint8_t)(v * 10), 0xBB);
|
||||||
|
return true;
|
||||||
|
}
|
||||||
|
bool Boiler::set_waitBoiler(const char * value, const int8_t id) {
|
||||||
|
int v;
|
||||||
|
if (!Helpers::value2number(value, v)) {
|
||||||
|
return false;
|
||||||
|
}
|
||||||
|
write_command(0xBB, 18, v, 0xBB);
|
||||||
|
return true;
|
||||||
|
}
|
||||||
|
bool Boiler::set_tempDiffBoiler(const char * value, const int8_t id) {
|
||||||
|
int v;
|
||||||
|
if (!Helpers::value2temperature(value, v, true)) {
|
||||||
|
return false;
|
||||||
|
}
|
||||||
|
write_command(0xBB, 19, v, 0xBB);
|
||||||
|
return true;
|
||||||
|
}
|
||||||
|
|
||||||
// Set the dhw temperature 0x33/0x35 or 0xEA
|
// Set the dhw temperature 0x33/0x35 or 0xEA
|
||||||
bool Boiler::set_ww_temp(const char * value, const int8_t id) {
|
bool Boiler::set_ww_temp(const char * value, const int8_t id) {
|
||||||
int v = 0;
|
int v = 0;
|
||||||
|
|||||||
@@ -193,6 +193,15 @@ class Boiler : public EMSdevice {
|
|||||||
// Pool unit
|
// Pool unit
|
||||||
int8_t poolSetTemp_;
|
int8_t poolSetTemp_;
|
||||||
|
|
||||||
|
// HybridHP
|
||||||
|
uint8_t gasPriceMode_; // cost = 2, temperature = 3, mix = 4
|
||||||
|
uint8_t switchOverTemp_; // degrees
|
||||||
|
uint8_t gasPriceRatio_; // is *10
|
||||||
|
uint8_t fossileFactor_; // is * 10
|
||||||
|
uint8_t electricFactor_; // is * 10
|
||||||
|
uint8_t waitBoiler_; // minutes
|
||||||
|
uint8_t tempDiffBoiler_; // relative temperature degrees
|
||||||
|
|
||||||
void process_UBAParameterWW(std::shared_ptr<const Telegram> telegram);
|
void process_UBAParameterWW(std::shared_ptr<const Telegram> telegram);
|
||||||
void process_UBAMonitorFast(std::shared_ptr<const Telegram> telegram);
|
void process_UBAMonitorFast(std::shared_ptr<const Telegram> telegram);
|
||||||
void process_UBATotalUptime(std::shared_ptr<const Telegram> telegram);
|
void process_UBATotalUptime(std::shared_ptr<const Telegram> telegram);
|
||||||
@@ -221,6 +230,7 @@ class Boiler : public EMSdevice {
|
|||||||
void process_HpPower(std::shared_ptr<const Telegram> telegram);
|
void process_HpPower(std::shared_ptr<const Telegram> telegram);
|
||||||
void process_HpOutdoor(std::shared_ptr<const Telegram> telegram);
|
void process_HpOutdoor(std::shared_ptr<const Telegram> telegram);
|
||||||
void process_HpPool(std::shared_ptr<const Telegram> telegram);
|
void process_HpPool(std::shared_ptr<const Telegram> telegram);
|
||||||
|
void process_HybridHp(std::shared_ptr<const Telegram> telegram);
|
||||||
|
|
||||||
// commands - none of these use the additional id parameter
|
// commands - none of these use the additional id parameter
|
||||||
bool set_ww_mode(const char * value, const int8_t id);
|
bool set_ww_mode(const char * value, const int8_t id);
|
||||||
@@ -256,6 +266,14 @@ class Boiler : public EMSdevice {
|
|||||||
bool set_ww_hyst_on(const char * value, const int8_t id);
|
bool set_ww_hyst_on(const char * value, const int8_t id);
|
||||||
bool set_ww_hyst_off(const char * value, const int8_t id);
|
bool set_ww_hyst_off(const char * value, const int8_t id);
|
||||||
bool set_pool_temp(const char * value, const int8_t id);
|
bool set_pool_temp(const char * value, const int8_t id);
|
||||||
|
|
||||||
|
bool set_gasPriceMode(const char * value, const int8_t id);
|
||||||
|
bool set_switchOverTemp(const char * value, const int8_t id);
|
||||||
|
bool set_gasPriceRatio(const char * value, const int8_t id);
|
||||||
|
bool set_fossileFactor(const char * value, const int8_t id);
|
||||||
|
bool set_electricFactor(const char * value, const int8_t id);
|
||||||
|
bool set_waitBoiler(const char * value, const int8_t id);
|
||||||
|
bool set_tempDiffBoiler(const char * value, const int8_t id);
|
||||||
};
|
};
|
||||||
|
|
||||||
} // namespace emsesp
|
} // namespace emsesp
|
||||||
|
|||||||
@@ -319,6 +319,7 @@ class EMSdevice {
|
|||||||
static constexpr uint8_t EMS_DEVICE_FLAG_EMSPLUS = 2;
|
static constexpr uint8_t EMS_DEVICE_FLAG_EMSPLUS = 2;
|
||||||
static constexpr uint8_t EMS_DEVICE_FLAG_HT3 = 3;
|
static constexpr uint8_t EMS_DEVICE_FLAG_HT3 = 3;
|
||||||
static constexpr uint8_t EMS_DEVICE_FLAG_HEATPUMP = 4;
|
static constexpr uint8_t EMS_DEVICE_FLAG_HEATPUMP = 4;
|
||||||
|
static constexpr uint8_t EMS_DEVICE_FLAG_HYBRID = 5;
|
||||||
|
|
||||||
// Solar Module
|
// Solar Module
|
||||||
static constexpr uint8_t EMS_DEVICE_FLAG_SM10 = 1;
|
static constexpr uint8_t EMS_DEVICE_FLAG_SM10 = 1;
|
||||||
|
|||||||
@@ -509,6 +509,16 @@ MAKE_PSTR_LIST(hpTl2, F("hptl2"), F("air inlet temperature (TL2)"))
|
|||||||
MAKE_PSTR_LIST(hpPl1, F("hppl1"), F("low pressure side temperature (PL1)"))
|
MAKE_PSTR_LIST(hpPl1, F("hppl1"), F("low pressure side temperature (PL1)"))
|
||||||
MAKE_PSTR_LIST(hpPh1, F("hpph1"), F("high pressure side temperature (PH1)"))
|
MAKE_PSTR_LIST(hpPh1, F("hpph1"), F("high pressure side temperature (PH1)"))
|
||||||
|
|
||||||
|
// hybrid heatpump
|
||||||
|
MAKE_PSTR_LIST(enum_gasPriceMode, F("co2"), F("cost"), F("temperature"), F("mix"))
|
||||||
|
MAKE_PSTR_LIST(gasPriceMode, F("gaspricemode"), F("gas price mode"))
|
||||||
|
MAKE_PSTR_LIST(switchOverTemp, F("switchovertemp"), F("switch over temperature"))
|
||||||
|
MAKE_PSTR_LIST(gasPriceRatio, F("gaspriceratio"), F("gas price ratio"))
|
||||||
|
MAKE_PSTR_LIST(fossileFactor, F("fossilefactor"), F("fossile factor"))
|
||||||
|
MAKE_PSTR_LIST(electricFactor, F("electricfactor"), F("electric factor"))
|
||||||
|
MAKE_PSTR_LIST(waitBoiler, F("waitboiler"), F("wait boiler"))
|
||||||
|
MAKE_PSTR_LIST(tempDiffBoiler, F("tempdiffboiler"), F("temperature difference boiler"))
|
||||||
|
|
||||||
// the following are dhw for the boiler and automatically tagged with 'ww'
|
// the following are dhw for the boiler and automatically tagged with 'ww'
|
||||||
MAKE_PSTR_LIST(wwSelTemp, F("wwseltemp"), F("selected temperature"))
|
MAKE_PSTR_LIST(wwSelTemp, F("wwseltemp"), F("selected temperature"))
|
||||||
MAKE_PSTR_LIST(wwSelTempLow, F("wwseltemplow"), F("selected lower temperature"))
|
MAKE_PSTR_LIST(wwSelTempLow, F("wwseltemplow"), F("selected lower temperature"))
|
||||||
|
|||||||
Reference in New Issue