Merge pull request #199 from kstaniek:MM100

MM100 EMS+ Status Message support added
This commit is contained in:
Proddy
2019-10-06 20:30:46 +02:00
committed by GitHub
4 changed files with 118 additions and 7 deletions

View File

@@ -458,10 +458,11 @@ void showInfo() {
myDebug_P(PSTR(" %d external temperature sensor%s found"), EMSESP_Settings.dallas_sensors, (EMSESP_Settings.dallas_sensors == 1) ? "" : "s");
}
myDebug_P(PSTR(" Boiler is %s, Thermostat is %s, Solar Module is %s, Shower Timer is %s, Shower Alert is %s"),
myDebug_P(PSTR(" Boiler is %s, Thermostat is %s, Solar Module is %s, Mixing Module is %s, Shower Timer is %s, Shower Alert is %s"),
(ems_getBoilerEnabled() ? "enabled" : "disabled"),
(ems_getThermostatEnabled() ? "enabled" : "disabled"),
(ems_getSolarModuleEnabled() ? "enabled" : "disabled"),
(ems_getMixingDeviceEnabled() ? "enabled" : "disabled"),
((EMSESP_Settings.shower_timer) ? "enabled" : "disabled"),
((EMSESP_Settings.shower_alert) ? "enabled" : "disabled"));
@@ -530,7 +531,6 @@ void showInfo() {
_renderIntValue("Selected flow temperature", "C", EMS_Boiler.selFlowTemp);
_renderUShortValue("Current flow temperature", "C", EMS_Boiler.curFlowTemp);
_renderUShortValue("Return temperature", "C", EMS_Boiler.retTemp);
_renderUShortValue("Switch temperature", "C", EMS_Boiler.switchTemp);
_renderBoolValue("Gas", EMS_Boiler.burnGas);
_renderBoolValue("Boiler pump", EMS_Boiler.heatPmp);
_renderBoolValue("Fan", EMS_Boiler.fanWork);
@@ -675,6 +675,20 @@ void showInfo() {
}
}
// Mixing modules sensors
if (ems_getMixingDeviceEnabled()) {
myDebug_P(PSTR("")); // newline
myDebug_P(PSTR("%sMixing module stats:%s"), COLOR_BOLD_ON, COLOR_BOLD_OFF);
_renderUShortValue("Switch temperature", "C", EMS_Boiler.switchTemp);
for (uint8_t hc_num = 1; hc_num <= EMS_THERMOSTAT_MAXHC; hc_num++) {
if (EMS_Mixing.hc[hc_num - 1].active) {
myDebug_P(PSTR(" Mixing Circuit %d"), hc_num);
_renderShortValue(" Current flow temperature", "C", EMS_Mixing.hc[hc_num - 1].flowTemp);
}
}
}
// Dallas external temp sensors
if (EMSESP_Settings.dallas_sensors != 0) {
myDebug_P(PSTR("")); // newline

View File

@@ -99,6 +99,9 @@ void _process_RCPLUSStatusMode(_EMS_RxTelegram * EMS_RxTelegram);
// Junkers FR10 & FW100
void _process_JunkersStatusMessage(_EMS_RxTelegram * EMS_RxTelegram);
// Mixers MM100
void _process_MMPLUSStatusMessage(_EMS_RxTelegram * EMS_RxTelegram);
/**
* Recognized EMS types and the functions they call to process the telegrams
* Format: MODEL ID, TYPE ID, Description, function, emsplus
@@ -184,8 +187,11 @@ const _EMS_Type EMS_Types[] = {
{EMS_MODEL_ALL, EMS_TYPE_RCPLUSStatusMode, "RCPLUSStatusMode", _process_RCPLUSStatusMode},
// Junkers FR10
{EMS_MODEL_ALL, EMS_TYPE_JunkersStatusMessage, "JunkersStatusMessage", _process_JunkersStatusMessage}
{EMS_MODEL_ALL, EMS_TYPE_JunkersStatusMessage, "JunkersStatusMessage", _process_JunkersStatusMessage},
// Mixing devices
{EMS_MODEL_MM100, EMS_TYPE_MMPLUSStatusMessage_HC1, "MMPLUSStatusMessage_HC1", _process_MMPLUSStatusMessage},
{EMS_MODEL_MM100, EMS_TYPE_MMPLUSStatusMessage_HC2, "MMPLUSStatusMessage_HC2", _process_MMPLUSStatusMessage},
};
@@ -196,13 +202,15 @@ uint8_t _SolarModule_Devices_max = ArraySize(SolarModule_Devices); // number of
uint8_t _Other_Devices_max = ArraySize(Other_Devices); // number of other ems devices
uint8_t _Thermostat_Devices_max = ArraySize(Thermostat_Devices); // number of defined thermostat types
uint8_t _HeatPump_Devices_max = ArraySize(HeatPump_Devices); // number of defined heatpump types
uint8_t _Mixing_Devices_max = ArraySize(Mixing_Devices); // number of mixing device types
// these structs contain the data we store from the specific EMS devices
_EMS_Boiler EMS_Boiler; // for boiler
_EMS_Thermostat EMS_Thermostat; // for thermostat
_EMS_SolarModule EMS_SolarModule; // for solar modules
_EMS_HeatPump EMS_HeatPump; // for heatpumps
_EMS_Other EMS_Other; // for other known EMS devices
_EMS_Mixing EMS_Mixing; // for mixing devices
_EMS_Other EMS_Other; // for other known EMS devices
// CRC lookup table with poly 12 for faster checking
const uint8_t ems_crc_table[] = {0x00, 0x02, 0x04, 0x06, 0x08, 0x0A, 0x0C, 0x0E, 0x10, 0x12, 0x14, 0x16, 0x18, 0x1A, 0x1C, 0x1E, 0x20, 0x22, 0x24, 0x26,
@@ -267,6 +275,16 @@ void ems_init() {
EMS_Thermostat.hc[i].curr_roomTemp = EMS_VALUE_SHORT_NOTSET;
}
EMS_Mixing.detected = false;
// init all mixing modules
for (uint8_t i = 0; i < EMS_THERMOSTAT_MAXHC; i++) {
EMS_Mixing.hc[i].hc = i + 1;
EMS_Mixing.hc[i].flowTemp = EMS_VALUE_SHORT_NOTSET;
EMS_Mixing.hc[i].device_id = EMS_ID_NONE;
EMS_Mixing.hc[i].model_id = EMS_MODEL_NONE;
EMS_Mixing.hc[i].product_id = EMS_ID_NONE;
}
// UBAParameterWW
EMS_Boiler.wWActivated = EMS_VALUE_INT_NOTSET; // Warm Water activated
EMS_Boiler.wWSelTemp = EMS_VALUE_INT_NOTSET; // Warm Water selected temperature
@@ -378,6 +396,10 @@ bool ems_getThermostatEnabled() {
return (EMS_Thermostat.device_id != EMS_ID_NONE);
}
bool ems_getMixingDeviceEnabled() {
return EMS_Mixing.detected;
}
bool ems_getSolarModuleEnabled() {
return (EMS_SolarModule.device_id != EMS_ID_NONE);
}
@@ -1465,6 +1487,20 @@ void _process_EasyStatusMessage(_EMS_RxTelegram * EMS_RxTelegram) {
EMS_Sys_Status.emsRefreshed = true; // triggers a send the values back via MQTT
}
void _process_MMPLUSStatusMessage(_EMS_RxTelegram * EMS_RxTelegram) {
uint8_t hc = (EMS_RxTelegram->type - EMS_TYPE_MMPLUSStatusMessage_HC1); // 0 to 3
if (hc > 4) {
return; // invalid type
}
EMS_Mixing.hc[hc].active = true;
if (EMS_RxTelegram->data_length == 1) {
} else if (EMS_RxTelegram->data_length > 8) {
EMS_Mixing.hc[hc].flowTemp = _toShort(EMS_OFFSET_MMPLUSStatusMessage_flow_temp);
}
}
/**
* type 0x01A5 - data from the Nefit RC1010/3000 thermostat (0x18) and RC300/310s on 0x10
* EMS+ messages may come in with different offsets so handle them here
@@ -1888,6 +1924,10 @@ void _addDevice(uint8_t model_type, uint8_t src, uint8_t product_id, char * vers
strlcat(device_type, "Heat Pump", sizeof(device_type));
strlcpy(device.model_string, HeatPump_Devices[i].model_string, sizeof(device.model_string));
break;
case EMS_MODELTYPE_MIXING:
strlcat(device_type, "Mixing Device", sizeof(device_type));
strlcpy(device.model_string, Mixing_Devices[i].model_string, sizeof(device.model_string));
break;
case EMS_MODELTYPE_OTHER:
strlcat(device_type, "Other", sizeof(device_type));
strlcpy(device.model_string, Other_Devices[i].model_string, sizeof(device.model_string));
@@ -2127,6 +2167,23 @@ void _process_Version(_EMS_RxTelegram * EMS_RxTelegram) {
return;
}
// look for mixing devices
i = 0;
while (i < _Mixing_Devices_max) {
if (Mixing_Devices[i].product_id == product_id) {
typeFound = true;
break;
}
i++;
}
if (typeFound) {
_addDevice(EMS_MODELTYPE_MIXING, EMS_RxTelegram->src, product_id, version, i);
ems_doReadCommand(EMS_TYPE_MMPLUSStatusMessage_HC1, EMS_RxTelegram->src);
EMS_Mixing.detected = true;
return;
}
// finally look for the other EMS devices
i = 0;
while (i < _Other_Devices_max) {

View File

@@ -132,6 +132,7 @@
#define EMS_MODELTYPE_HP 4 // success color
#define EMS_MODELTYPE_OTHER 5 // no color
#define EMS_MODELTYPE_UNKNOWN 6 // no color
#define EMS_MODELTYPE_MIXING 7
#define EMS_MODELTYPE_UNKNOWN_STRING "unknown?" // model type text to use when discovering an unknown device
@@ -273,6 +274,12 @@ typedef struct {
bool write_supported;
} _Thermostat_Device;
typedef struct {
uint8_t product_id;
uint8_t device_id;
char model_string[50];
} _Mixing_Device;
// for consolidating all types
typedef struct {
uint8_t model_type; // 1=boiler, 2=thermostat, 3=sm, 4=other, 5=unknown
@@ -282,6 +289,7 @@ typedef struct {
char model_string[50];
} _Generic_Device;
/*
* Telegram package defintions
*/
@@ -365,6 +373,23 @@ typedef struct {
char version[10];
} _EMS_Other;
typedef struct {
uint8_t device_id;
uint8_t model_id;
uint8_t product_id;
char version[10];
uint8_t hc; // heating circuit 1,2, 3 or 4
bool active; // true if there is data for this HC
uint8_t flowTemp;
} _EMS_Mixing_HC;
// Mixer data
typedef struct {
bool detected;
_EMS_Mixing_HC hc[EMS_THERMOSTAT_MAXHC]; // array for the 4 heating circuits
} _EMS_Mixing;
// SM Solar Module - SM10/SM100/ISM1
typedef struct {
uint8_t device_id; // the device ID of the Solar Module
@@ -464,6 +489,7 @@ void ems_getSolarModuleValues();
bool ems_getPoll();
bool ems_getTxEnabled();
bool ems_getThermostatEnabled();
bool ems_getMixingDeviceEnabled();
bool ems_getBoilerEnabled();
bool ems_getSolarModuleEnabled();
bool ems_getHeatPumpEnabled();
@@ -492,5 +518,6 @@ extern _EMS_Thermostat EMS_Thermostat;
extern _EMS_SolarModule EMS_SolarModule;
extern _EMS_HeatPump EMS_HeatPump;
extern _EMS_Other EMS_Other;
extern _EMS_Mixing EMS_Mixing;
extern std::list<_Generic_Device> Devices;

View File

@@ -144,6 +144,13 @@
#define EMS_OFFSET_JunkersStatusMessage_setpoint 2 // setpoint temp
#define EMS_OFFSET_JunkersStatusMessage_curr 4 // current temp
// MM100 (EMS Plus)
#define EMS_TYPE_MMPLUSStatusMessage_HC1 0x01D7 // mixer status HC1
#define EMS_TYPE_MMPLUSStatusMessage_HC2 0x01D8 // mixer status HC2
#define EMS_TYPE_MMPLUSStatusMessage_HC3 0x01D9 // mixer status HC3
#define EMS_TYPE_MMPLUSStatusMessage_HC4 0x01DA // mixer status HC4
#define EMS_OFFSET_MMPLUSStatusMessage_flow_temp 3 // flow temperature
// Known EMS devices
typedef enum {
@@ -175,7 +182,10 @@ typedef enum {
EMS_MODEL_FR10,
EMS_MODEL_FR100,
EMS_MODEL_FR110,
EMS_MODEL_FW120
EMS_MODEL_FW120,
// mixing devices
EMS_MODEL_MM100
} _EMS_MODEL_ID;
@@ -210,6 +220,11 @@ const _SolarModule_Device SolarModule_Devices[] = {
};
const _Mixing_Device Mixing_Devices[] = {
{160, 0x20, "MM100 Mixing Module"},
{160, 0x21, "MM100 Mixing Module"},
};
// Other EMS devices which are not considered boilers, thermostats or solar modules
// format is PRODUCT ID, DEVICE ID, DESCRIPTION
const _Other_Device Other_Devices[] = {
@@ -217,8 +232,6 @@ const _Other_Device Other_Devices[] = {
{71, 0x11, "WM10 Switch Module"},
{69, 0x21, "MM10 Mixer Module"},
{160, 0x20, "MM100 Mixing Module"},
{160, 0x21, "MM100 Mixing Module"},
{159, 0x21, "MM50 Mixing Module"},
{68, 0x09, "BC10/RFM20 Receiver"},