chore: update generated files for v3.8.1-dev.4

This commit is contained in:
MichaelDvP
2026-01-07 08:17:16 +00:00
committed by github-actions[bot]
parent d9551bc4c3
commit 738d6f0b0f
4 changed files with 197 additions and 170 deletions

View File

@@ -9283,59 +9283,64 @@ uint8
| heatingpumpmod | heating pump modulation | uint8 (>=0<=100) | % | false | DEVICE_DATA | 14 | 1 | 1 | | heatingpumpmod | heating pump modulation | uint8 (>=0<=100) | % | false | DEVICE_DATA | 14 | 1 | 1 |
uint8 uint8
| hpcompspd | compressor speed | uint8 (>=0<=100) | % | false | DEVICE_DATA | 15 | 1 | 1 | | hpcompspd | compressor speed | uint8 (>=0<=100) | % | false | DEVICE_DATA | 15 | 1 | 1 |
| hybridstrategy | hybrid control strategy | enum | | true | DEVICE_DATA | 16 | 1 | 1 | | hpactivity | compressor activity | enum | | false | DEVICE_DATA | 16 | 1 | 1 |
| lownoisemode | low noise mode | enum | | true | DEVICE_DATA | 17 | 1 | 1 | uint16
| hppower | compressor power output | uint16 (>=0<=31999) | W | false | DEVICE_DATA | 17 | 1 | 1 |
uint16
| hpcurrpower | compressor current power | uint16 (>=0<=31999) | W | false | DEVICE_DATA | 18 | 1 | 1 |
| hybridstrategy | hybrid control strategy | enum | | true | DEVICE_DATA | 19 | 1 | 1 |
| lownoisemode | low noise mode | enum | | true | DEVICE_DATA | 20 | 1 | 1 |
uint8 uint8
| lownoisestart | low noise starttime | uint8 (>=0<=23) | hours | true | DEVICE_DATA | 18 | 1 | 1 | | lownoisestart | low noise starttime | uint8 (>=0<=23) | hours | true | DEVICE_DATA | 21 | 1 | 1 |
uint8 uint8
| lownoisestop | low noise stoptime | uint8 (>=0<=23) | hours | true | DEVICE_DATA | 19 | 1 | 1 | | lownoisestop | low noise stoptime | uint8 (>=0<=23) | hours | true | DEVICE_DATA | 22 | 1 | 1 |
| dhw.hybriddhw | hybrid DHW | enum | | true | DHW | 0 | 1 | 1 | | dhw.hybriddhw | hybrid DHW | enum | | true | DHW | 0 | 1 | 1 |
uint8 uint8
| energypricegas | energy price gas | uint8 (>=0<=254) | ct/kWh | true | DEVICE_DATA | 20 | 1 | 1 | | energypricegas | energy price gas | uint8 (>=0<=254) | ct/kWh | true | DEVICE_DATA | 23 | 1 | 1 |
uint8 uint8
| energypriceel | energy price electric | uint8 (>=0<=254) | ct/kWh | true | DEVICE_DATA | 21 | 1 | 1 | | energypriceel | energy price electric | uint8 (>=0<=254) | ct/kWh | true | DEVICE_DATA | 24 | 1 | 1 |
uint8 uint8
| energyfeedpv | feed in PV | uint8 (>=0<=254) | ct/kWh | true | DEVICE_DATA | 22 | 1 | 1 | | energyfeedpv | feed in PV | uint8 (>=0<=254) | ct/kWh | true | DEVICE_DATA | 25 | 1 | 1 |
int8 int8
| switchovertemp | outside switchover temperature | int8 (>=-126<=126) | C | true | DEVICE_DATA | 23 | 1 | 1 | | switchovertemp | outside switchover temperature | int8 (>=-126<=126) | C | true | DEVICE_DATA | 26 | 1 | 1 |
| airpurgemode | air purge mode | boolean | | true | DEVICE_DATA | 24 | 1 | 1 | | airpurgemode | air purge mode | boolean | | true | DEVICE_DATA | 27 | 1 | 1 |
uint8 uint8
| heatpumpoutput | heatpump output | uint8 (>=0<=100) | % | true | DEVICE_DATA | 25 | 1 | 1 | | heatpumpoutput | heatpump output | uint8 (>=0<=100) | % | true | DEVICE_DATA | 28 | 1 | 1 |
| coolingcircuit | cooling circuit | boolean | | true | DEVICE_DATA | 26 | 1 | 1 | | coolingcircuit | cooling circuit | boolean | | true | DEVICE_DATA | 29 | 1 | 1 |
uint8 uint8
| compstartmod | compressor start modulation | uint8 (>=0<=100) | % | true | DEVICE_DATA | 27 | 1 | 1 | | compstartmod | compressor start modulation | uint8 (>=0<=100) | % | true | DEVICE_DATA | 30 | 1 | 1 |
| heatdrainpan | heat drain pan | boolean | | true | DEVICE_DATA | 28 | 1 | 1 | | heatdrainpan | heat drain pan | boolean | | true | DEVICE_DATA | 31 | 1 | 1 |
| heatcable | heating cable | boolean | | true | DEVICE_DATA | 29 | 1 | 1 | | heatcable | heating cable | boolean | | true | DEVICE_DATA | 32 | 1 | 1 |
uint24 uint24
| nrgtotal | total energy | uint24 (>=0<=167772) | kWh | false | DEVICE_DATA | 30 | 2 | 1/100 | | nrgtotal | total energy | uint24 (>=0<=167772) | kWh | false | DEVICE_DATA | 33 | 2 | 1/100 |
uint24 uint24
| dhw.nrg | energy | uint24 (>=0<=167772) | kWh | false | DHW | 1 | 2 | 1/100 | | dhw.nrg | energy | uint24 (>=0<=167772) | kWh | false | DHW | 1 | 2 | 1/100 |
uint24 uint24
| nrgheat | energy heating | uint24 (>=0<=167772) | kWh | false | DEVICE_DATA | 32 | 2 | 1/100 | | nrgheat | energy heating | uint24 (>=0<=167772) | kWh | false | DEVICE_DATA | 35 | 2 | 1/100 |
uint24 uint24
| metertotal | meter total | uint24 (>=0<=167772) | kWh | false | DEVICE_DATA | 34 | 2 | 1/100 | | metertotal | meter total | uint24 (>=0<=167772) | kWh | false | DEVICE_DATA | 37 | 2 | 1/100 |
uint24 uint24
| metercomp | meter compressor | uint24 (>=0<=167772) | kWh | false | DEVICE_DATA | 36 | 2 | 1/100 | | metercomp | meter compressor | uint24 (>=0<=167772) | kWh | false | DEVICE_DATA | 39 | 2 | 1/100 |
uint24 uint24
| metereheat | meter e-heater | uint24 (>=0<=167772) | kWh | false | DEVICE_DATA | 38 | 2 | 1/100 | | metereheat | meter e-heater | uint24 (>=0<=167772) | kWh | false | DEVICE_DATA | 41 | 2 | 1/100 |
uint24 uint24
| meterheat | meter heating | uint24 (>=0<=167772) | kWh | false | DEVICE_DATA | 40 | 2 | 1/100 | | meterheat | meter heating | uint24 (>=0<=167772) | kWh | false | DEVICE_DATA | 43 | 2 | 1/100 |
uint24 uint24
| dhw.meter | meter | uint24 (>=0<=167772) | kWh | false | DHW | 3 | 2 | 1/100 | | dhw.meter | meter | uint24 (>=0<=167772) | kWh | false | DHW | 3 | 2 | 1/100 |
uint24 uint24
| heatingstarts | heating control starts | uint24 (>=0<=16777214) | | false | DEVICE_DATA | 42 | 2 | 1 | | heatingstarts | heating control starts | uint24 (>=0<=16777214) | | false | DEVICE_DATA | 45 | 2 | 1 |
uint24 uint24
| dhw.startshp | starts hp | uint24 (>=0<=16777214) | | false | DHW | 5 | 2 | 1 | | dhw.startshp | starts hp | uint24 (>=0<=16777214) | | false | DHW | 5 | 2 | 1 |
uint32 uint32
| fuelheat | fuel consumption heating | uint32 (>=0<=1677721) | kWh | false | DEVICE_DATA | 44 | 2 | 1/10 | | fuelheat | fuel consumption heating | uint32 (>=0<=1677721) | kWh | false | DEVICE_DATA | 47 | 2 | 1/10 |
uint32 uint32
| dhw.fueldhw | fuel consumption | uint32 (>=0<=1677721) | kWh | false | DHW | 7 | 2 | 1/10 | | dhw.fueldhw | fuel consumption | uint32 (>=0<=1677721) | kWh | false | DHW | 7 | 2 | 1/10 |
uint32 uint32
| elheat | el. consumption heating | uint32 (>=0<=1677721) | kWh | false | DEVICE_DATA | 46 | 2 | 1/10 | | elheat | el. consumption heating | uint32 (>=0<=1677721) | kWh | false | DEVICE_DATA | 49 | 2 | 1/10 |
uint32 uint32
| dhw.eldhw | el. consumption | uint32 (>=0<=1677721) | kWh | false | DHW | 9 | 2 | 1/10 | | dhw.eldhw | el. consumption | uint32 (>=0<=1677721) | kWh | false | DHW | 9 | 2 | 1/10 |
uint32 uint32
| elgenheat | el. generation heating | uint32 (>=0<=1677721) | kWh | false | DEVICE_DATA | 48 | 2 | 1/10 | | elgenheat | el. generation heating | uint32 (>=0<=1677721) | kWh | false | DEVICE_DATA | 51 | 2 | 1/10 |
uint32 uint32
| dhw.elgendhw | el generation | uint32 (>=0<=1677721) | kWh | false | DHW | 11 | 2 | 1/10 | | dhw.elgendhw | el generation | uint32 (>=0<=1677721) | kWh | false | DHW | 11 | 2 | 1/10 |
@@ -9375,59 +9380,64 @@ uint8
| heatingpumpmod | heating pump modulation | uint8 (>=0<=100) | % | false | DEVICE_DATA | 14 | 1 | 1 | | heatingpumpmod | heating pump modulation | uint8 (>=0<=100) | % | false | DEVICE_DATA | 14 | 1 | 1 |
uint8 uint8
| hpcompspd | compressor speed | uint8 (>=0<=100) | % | false | DEVICE_DATA | 15 | 1 | 1 | | hpcompspd | compressor speed | uint8 (>=0<=100) | % | false | DEVICE_DATA | 15 | 1 | 1 |
| hybridstrategy | hybrid control strategy | enum | | true | DEVICE_DATA | 16 | 1 | 1 | | hpactivity | compressor activity | enum | | false | DEVICE_DATA | 16 | 1 | 1 |
| lownoisemode | low noise mode | enum | | true | DEVICE_DATA | 17 | 1 | 1 | uint16
| hppower | compressor power output | uint16 (>=0<=31999) | W | false | DEVICE_DATA | 17 | 1 | 1 |
uint16
| hpcurrpower | compressor current power | uint16 (>=0<=31999) | W | false | DEVICE_DATA | 18 | 1 | 1 |
| hybridstrategy | hybrid control strategy | enum | | true | DEVICE_DATA | 19 | 1 | 1 |
| lownoisemode | low noise mode | enum | | true | DEVICE_DATA | 20 | 1 | 1 |
uint8 uint8
| lownoisestart | low noise starttime | uint8 (>=0<=23) | hours | true | DEVICE_DATA | 18 | 1 | 1 | | lownoisestart | low noise starttime | uint8 (>=0<=23) | hours | true | DEVICE_DATA | 21 | 1 | 1 |
uint8 uint8
| lownoisestop | low noise stoptime | uint8 (>=0<=23) | hours | true | DEVICE_DATA | 19 | 1 | 1 | | lownoisestop | low noise stoptime | uint8 (>=0<=23) | hours | true | DEVICE_DATA | 22 | 1 | 1 |
| dhw.hybriddhw | hybrid DHW | enum | | true | DHW | 0 | 1 | 1 | | dhw.hybriddhw | hybrid DHW | enum | | true | DHW | 0 | 1 | 1 |
uint8 uint8
| energypricegas | energy price gas | uint8 (>=0<=254) | ct/kWh | true | DEVICE_DATA | 20 | 1 | 1 | | energypricegas | energy price gas | uint8 (>=0<=254) | ct/kWh | true | DEVICE_DATA | 23 | 1 | 1 |
uint8 uint8
| energypriceel | energy price electric | uint8 (>=0<=254) | ct/kWh | true | DEVICE_DATA | 21 | 1 | 1 | | energypriceel | energy price electric | uint8 (>=0<=254) | ct/kWh | true | DEVICE_DATA | 24 | 1 | 1 |
uint8 uint8
| energyfeedpv | feed in PV | uint8 (>=0<=254) | ct/kWh | true | DEVICE_DATA | 22 | 1 | 1 | | energyfeedpv | feed in PV | uint8 (>=0<=254) | ct/kWh | true | DEVICE_DATA | 25 | 1 | 1 |
int8 int8
| switchovertemp | outside switchover temperature | int8 (>=-126<=126) | C | true | DEVICE_DATA | 23 | 1 | 1 | | switchovertemp | outside switchover temperature | int8 (>=-126<=126) | C | true | DEVICE_DATA | 26 | 1 | 1 |
| airpurgemode | air purge mode | boolean | | true | DEVICE_DATA | 24 | 1 | 1 | | airpurgemode | air purge mode | boolean | | true | DEVICE_DATA | 27 | 1 | 1 |
uint8 uint8
| heatpumpoutput | heatpump output | uint8 (>=0<=100) | % | true | DEVICE_DATA | 25 | 1 | 1 | | heatpumpoutput | heatpump output | uint8 (>=0<=100) | % | true | DEVICE_DATA | 28 | 1 | 1 |
| coolingcircuit | cooling circuit | boolean | | true | DEVICE_DATA | 26 | 1 | 1 | | coolingcircuit | cooling circuit | boolean | | true | DEVICE_DATA | 29 | 1 | 1 |
uint8 uint8
| compstartmod | compressor start modulation | uint8 (>=0<=100) | % | true | DEVICE_DATA | 27 | 1 | 1 | | compstartmod | compressor start modulation | uint8 (>=0<=100) | % | true | DEVICE_DATA | 30 | 1 | 1 |
| heatdrainpan | heat drain pan | boolean | | true | DEVICE_DATA | 28 | 1 | 1 | | heatdrainpan | heat drain pan | boolean | | true | DEVICE_DATA | 31 | 1 | 1 |
| heatcable | heating cable | boolean | | true | DEVICE_DATA | 29 | 1 | 1 | | heatcable | heating cable | boolean | | true | DEVICE_DATA | 32 | 1 | 1 |
uint24 uint24
| nrgtotal | total energy | uint24 (>=0<=167772) | kWh | false | DEVICE_DATA | 30 | 2 | 1/100 | | nrgtotal | total energy | uint24 (>=0<=167772) | kWh | false | DEVICE_DATA | 33 | 2 | 1/100 |
uint24 uint24
| dhw.nrg | energy | uint24 (>=0<=167772) | kWh | false | DHW | 1 | 2 | 1/100 | | dhw.nrg | energy | uint24 (>=0<=167772) | kWh | false | DHW | 1 | 2 | 1/100 |
uint24 uint24
| nrgheat | energy heating | uint24 (>=0<=167772) | kWh | false | DEVICE_DATA | 32 | 2 | 1/100 | | nrgheat | energy heating | uint24 (>=0<=167772) | kWh | false | DEVICE_DATA | 35 | 2 | 1/100 |
uint24 uint24
| metertotal | meter total | uint24 (>=0<=167772) | kWh | false | DEVICE_DATA | 34 | 2 | 1/100 | | metertotal | meter total | uint24 (>=0<=167772) | kWh | false | DEVICE_DATA | 37 | 2 | 1/100 |
uint24 uint24
| metercomp | meter compressor | uint24 (>=0<=167772) | kWh | false | DEVICE_DATA | 36 | 2 | 1/100 | | metercomp | meter compressor | uint24 (>=0<=167772) | kWh | false | DEVICE_DATA | 39 | 2 | 1/100 |
uint24 uint24
| metereheat | meter e-heater | uint24 (>=0<=167772) | kWh | false | DEVICE_DATA | 38 | 2 | 1/100 | | metereheat | meter e-heater | uint24 (>=0<=167772) | kWh | false | DEVICE_DATA | 41 | 2 | 1/100 |
uint24 uint24
| meterheat | meter heating | uint24 (>=0<=167772) | kWh | false | DEVICE_DATA | 40 | 2 | 1/100 | | meterheat | meter heating | uint24 (>=0<=167772) | kWh | false | DEVICE_DATA | 43 | 2 | 1/100 |
uint24 uint24
| dhw.meter | meter | uint24 (>=0<=167772) | kWh | false | DHW | 3 | 2 | 1/100 | | dhw.meter | meter | uint24 (>=0<=167772) | kWh | false | DHW | 3 | 2 | 1/100 |
uint24 uint24
| heatingstarts | heating control starts | uint24 (>=0<=16777214) | | false | DEVICE_DATA | 42 | 2 | 1 | | heatingstarts | heating control starts | uint24 (>=0<=16777214) | | false | DEVICE_DATA | 45 | 2 | 1 |
uint24 uint24
| dhw.startshp | starts hp | uint24 (>=0<=16777214) | | false | DHW | 5 | 2 | 1 | | dhw.startshp | starts hp | uint24 (>=0<=16777214) | | false | DHW | 5 | 2 | 1 |
uint32 uint32
| fuelheat | fuel consumption heating | uint32 (>=0<=1677721) | kWh | false | DEVICE_DATA | 44 | 2 | 1/10 | | fuelheat | fuel consumption heating | uint32 (>=0<=1677721) | kWh | false | DEVICE_DATA | 47 | 2 | 1/10 |
uint32 uint32
| dhw.fueldhw | fuel consumption | uint32 (>=0<=1677721) | kWh | false | DHW | 7 | 2 | 1/10 | | dhw.fueldhw | fuel consumption | uint32 (>=0<=1677721) | kWh | false | DHW | 7 | 2 | 1/10 |
uint32 uint32
| elheat | el. consumption heating | uint32 (>=0<=1677721) | kWh | false | DEVICE_DATA | 46 | 2 | 1/10 | | elheat | el. consumption heating | uint32 (>=0<=1677721) | kWh | false | DEVICE_DATA | 49 | 2 | 1/10 |
uint32 uint32
| dhw.eldhw | el. consumption | uint32 (>=0<=1677721) | kWh | false | DHW | 9 | 2 | 1/10 | | dhw.eldhw | el. consumption | uint32 (>=0<=1677721) | kWh | false | DHW | 9 | 2 | 1/10 |
uint32 uint32
| elgenheat | el. generation heating | uint32 (>=0<=1677721) | kWh | false | DEVICE_DATA | 48 | 2 | 1/10 | | elgenheat | el. generation heating | uint32 (>=0<=1677721) | kWh | false | DEVICE_DATA | 51 | 2 | 1/10 |
uint32 uint32
| dhw.elgendhw | el generation | uint32 (>=0<=1677721) | kWh | false | DHW | 11 | 2 | 1/10 | | dhw.elgendhw | el generation | uint32 (>=0<=1677721) | kWh | false | DHW | 11 | 2 | 1/10 |
@@ -9467,59 +9477,64 @@ uint8
| heatingpumpmod | heating pump modulation | uint8 (>=0<=100) | % | false | DEVICE_DATA | 14 | 1 | 1 | | heatingpumpmod | heating pump modulation | uint8 (>=0<=100) | % | false | DEVICE_DATA | 14 | 1 | 1 |
uint8 uint8
| hpcompspd | compressor speed | uint8 (>=0<=100) | % | false | DEVICE_DATA | 15 | 1 | 1 | | hpcompspd | compressor speed | uint8 (>=0<=100) | % | false | DEVICE_DATA | 15 | 1 | 1 |
| hybridstrategy | hybrid control strategy | enum | | true | DEVICE_DATA | 16 | 1 | 1 | | hpactivity | compressor activity | enum | | false | DEVICE_DATA | 16 | 1 | 1 |
| lownoisemode | low noise mode | enum | | true | DEVICE_DATA | 17 | 1 | 1 | uint16
| hppower | compressor power output | uint16 (>=0<=31999) | W | false | DEVICE_DATA | 17 | 1 | 1 |
uint16
| hpcurrpower | compressor current power | uint16 (>=0<=31999) | W | false | DEVICE_DATA | 18 | 1 | 1 |
| hybridstrategy | hybrid control strategy | enum | | true | DEVICE_DATA | 19 | 1 | 1 |
| lownoisemode | low noise mode | enum | | true | DEVICE_DATA | 20 | 1 | 1 |
uint8 uint8
| lownoisestart | low noise starttime | uint8 (>=0<=23) | hours | true | DEVICE_DATA | 18 | 1 | 1 | | lownoisestart | low noise starttime | uint8 (>=0<=23) | hours | true | DEVICE_DATA | 21 | 1 | 1 |
uint8 uint8
| lownoisestop | low noise stoptime | uint8 (>=0<=23) | hours | true | DEVICE_DATA | 19 | 1 | 1 | | lownoisestop | low noise stoptime | uint8 (>=0<=23) | hours | true | DEVICE_DATA | 22 | 1 | 1 |
| dhw.hybriddhw | hybrid DHW | enum | | true | DHW | 0 | 1 | 1 | | dhw.hybriddhw | hybrid DHW | enum | | true | DHW | 0 | 1 | 1 |
uint8 uint8
| energypricegas | energy price gas | uint8 (>=0<=254) | ct/kWh | true | DEVICE_DATA | 20 | 1 | 1 | | energypricegas | energy price gas | uint8 (>=0<=254) | ct/kWh | true | DEVICE_DATA | 23 | 1 | 1 |
uint8 uint8
| energypriceel | energy price electric | uint8 (>=0<=254) | ct/kWh | true | DEVICE_DATA | 21 | 1 | 1 | | energypriceel | energy price electric | uint8 (>=0<=254) | ct/kWh | true | DEVICE_DATA | 24 | 1 | 1 |
uint8 uint8
| energyfeedpv | feed in PV | uint8 (>=0<=254) | ct/kWh | true | DEVICE_DATA | 22 | 1 | 1 | | energyfeedpv | feed in PV | uint8 (>=0<=254) | ct/kWh | true | DEVICE_DATA | 25 | 1 | 1 |
int8 int8
| switchovertemp | outside switchover temperature | int8 (>=-126<=126) | C | true | DEVICE_DATA | 23 | 1 | 1 | | switchovertemp | outside switchover temperature | int8 (>=-126<=126) | C | true | DEVICE_DATA | 26 | 1 | 1 |
| airpurgemode | air purge mode | boolean | | true | DEVICE_DATA | 24 | 1 | 1 | | airpurgemode | air purge mode | boolean | | true | DEVICE_DATA | 27 | 1 | 1 |
uint8 uint8
| heatpumpoutput | heatpump output | uint8 (>=0<=100) | % | true | DEVICE_DATA | 25 | 1 | 1 | | heatpumpoutput | heatpump output | uint8 (>=0<=100) | % | true | DEVICE_DATA | 28 | 1 | 1 |
| coolingcircuit | cooling circuit | boolean | | true | DEVICE_DATA | 26 | 1 | 1 | | coolingcircuit | cooling circuit | boolean | | true | DEVICE_DATA | 29 | 1 | 1 |
uint8 uint8
| compstartmod | compressor start modulation | uint8 (>=0<=100) | % | true | DEVICE_DATA | 27 | 1 | 1 | | compstartmod | compressor start modulation | uint8 (>=0<=100) | % | true | DEVICE_DATA | 30 | 1 | 1 |
| heatdrainpan | heat drain pan | boolean | | true | DEVICE_DATA | 28 | 1 | 1 | | heatdrainpan | heat drain pan | boolean | | true | DEVICE_DATA | 31 | 1 | 1 |
| heatcable | heating cable | boolean | | true | DEVICE_DATA | 29 | 1 | 1 | | heatcable | heating cable | boolean | | true | DEVICE_DATA | 32 | 1 | 1 |
uint24 uint24
| nrgtotal | total energy | uint24 (>=0<=167772) | kWh | false | DEVICE_DATA | 30 | 2 | 1/100 | | nrgtotal | total energy | uint24 (>=0<=167772) | kWh | false | DEVICE_DATA | 33 | 2 | 1/100 |
uint24 uint24
| dhw.nrg | energy | uint24 (>=0<=167772) | kWh | false | DHW | 1 | 2 | 1/100 | | dhw.nrg | energy | uint24 (>=0<=167772) | kWh | false | DHW | 1 | 2 | 1/100 |
uint24 uint24
| nrgheat | energy heating | uint24 (>=0<=167772) | kWh | false | DEVICE_DATA | 32 | 2 | 1/100 | | nrgheat | energy heating | uint24 (>=0<=167772) | kWh | false | DEVICE_DATA | 35 | 2 | 1/100 |
uint24 uint24
| metertotal | meter total | uint24 (>=0<=167772) | kWh | false | DEVICE_DATA | 34 | 2 | 1/100 | | metertotal | meter total | uint24 (>=0<=167772) | kWh | false | DEVICE_DATA | 37 | 2 | 1/100 |
uint24 uint24
| metercomp | meter compressor | uint24 (>=0<=167772) | kWh | false | DEVICE_DATA | 36 | 2 | 1/100 | | metercomp | meter compressor | uint24 (>=0<=167772) | kWh | false | DEVICE_DATA | 39 | 2 | 1/100 |
uint24 uint24
| metereheat | meter e-heater | uint24 (>=0<=167772) | kWh | false | DEVICE_DATA | 38 | 2 | 1/100 | | metereheat | meter e-heater | uint24 (>=0<=167772) | kWh | false | DEVICE_DATA | 41 | 2 | 1/100 |
uint24 uint24
| meterheat | meter heating | uint24 (>=0<=167772) | kWh | false | DEVICE_DATA | 40 | 2 | 1/100 | | meterheat | meter heating | uint24 (>=0<=167772) | kWh | false | DEVICE_DATA | 43 | 2 | 1/100 |
uint24 uint24
| dhw.meter | meter | uint24 (>=0<=167772) | kWh | false | DHW | 3 | 2 | 1/100 | | dhw.meter | meter | uint24 (>=0<=167772) | kWh | false | DHW | 3 | 2 | 1/100 |
uint24 uint24
| heatingstarts | heating control starts | uint24 (>=0<=16777214) | | false | DEVICE_DATA | 42 | 2 | 1 | | heatingstarts | heating control starts | uint24 (>=0<=16777214) | | false | DEVICE_DATA | 45 | 2 | 1 |
uint24 uint24
| dhw.startshp | starts hp | uint24 (>=0<=16777214) | | false | DHW | 5 | 2 | 1 | | dhw.startshp | starts hp | uint24 (>=0<=16777214) | | false | DHW | 5 | 2 | 1 |
uint32 uint32
| fuelheat | fuel consumption heating | uint32 (>=0<=1677721) | kWh | false | DEVICE_DATA | 44 | 2 | 1/10 | | fuelheat | fuel consumption heating | uint32 (>=0<=1677721) | kWh | false | DEVICE_DATA | 47 | 2 | 1/10 |
uint32 uint32
| dhw.fueldhw | fuel consumption | uint32 (>=0<=1677721) | kWh | false | DHW | 7 | 2 | 1/10 | | dhw.fueldhw | fuel consumption | uint32 (>=0<=1677721) | kWh | false | DHW | 7 | 2 | 1/10 |
uint32 uint32
| elheat | el. consumption heating | uint32 (>=0<=1677721) | kWh | false | DEVICE_DATA | 46 | 2 | 1/10 | | elheat | el. consumption heating | uint32 (>=0<=1677721) | kWh | false | DEVICE_DATA | 49 | 2 | 1/10 |
uint32 uint32
| dhw.eldhw | el. consumption | uint32 (>=0<=1677721) | kWh | false | DHW | 9 | 2 | 1/10 | | dhw.eldhw | el. consumption | uint32 (>=0<=1677721) | kWh | false | DHW | 9 | 2 | 1/10 |
uint32 uint32
| elgenheat | el. generation heating | uint32 (>=0<=1677721) | kWh | false | DEVICE_DATA | 48 | 2 | 1/10 | | elgenheat | el. generation heating | uint32 (>=0<=1677721) | kWh | false | DEVICE_DATA | 51 | 2 | 1/10 |
uint32 uint32
| dhw.elgendhw | el generation | uint32 (>=0<=1677721) | kWh | false | DHW | 11 | 2 | 1/10 | | dhw.elgendhw | el generation | uint32 (>=0<=1677721) | kWh | false | DHW | 11 | 2 | 1/10 |

View File

@@ -5609,36 +5609,39 @@ device name,device type,product id,shortname,fullname,type [options...] \| (min/
"HP Module",heatpump,252,hpph1,high pressure side temperature (PH1),int16 (>=-3199<=3199),C,false,sensor.heatpump_high_pressure_side_temperature_(PH1),sensor.heatpump_hpph1,9,0,1/10,13,1 "HP Module",heatpump,252,hpph1,high pressure side temperature (PH1),int16 (>=-3199<=3199),C,false,sensor.heatpump_high_pressure_side_temperature_(PH1),sensor.heatpump_hpph1,9,0,1/10,13,1
"HP Module",heatpump,252,heatingpumpmod,heating pump modulation,uint8 (>=0<=100),%,false,sensor.heatpump_heating_pump_modulation,sensor.heatpump_heatingpumpmod,9,0,1,14,1 "HP Module",heatpump,252,heatingpumpmod,heating pump modulation,uint8 (>=0<=100),%,false,sensor.heatpump_heating_pump_modulation,sensor.heatpump_heatingpumpmod,9,0,1,14,1
"HP Module",heatpump,252,hpcompspd,compressor speed,uint8 (>=0<=100),%,false,sensor.heatpump_compressor_speed,sensor.heatpump_hpcompspd,9,0,1,15,1 "HP Module",heatpump,252,hpcompspd,compressor speed,uint8 (>=0<=100),%,false,sensor.heatpump_compressor_speed,sensor.heatpump_hpcompspd,9,0,1,15,1
"HP Module",heatpump,252,hybridstrategy,hybrid control strategy,enum [cost optimized\|co2 optimized\|outside temperature alt.\|outside temperature parallel\|heatpump preferred\|boiler only], ,true,select.heatpump_hybrid_control_strategy,select.heatpump_hybridstrategy,9,0,1,16,1 "HP Module",heatpump,252,hpactivity,compressor activity,enum [off\|heating\|hot water\|defrost\|compressor alarm], ,false,sensor.heatpump_compressor_activity,sensor.heatpump_hpactivity,9,0,1,16,1
"HP Module",heatpump,252,lownoisemode,low noise mode,enum [off\|reduced output\|switch off hp\|perm. reduced], ,true,select.heatpump_low_noise_mode,select.heatpump_lownoisemode,9,0,1,17,1 "HP Module",heatpump,252,hppower,compressor power output,uint16 (>=0<=31999),W,false,sensor.heatpump_compressor_power_output,sensor.heatpump_hppower,9,0,1,17,1
"HP Module",heatpump,252,lownoisestart,low noise starttime,uint8 (>=0<=23),hours,true,number.heatpump_low_noise_starttime,number.heatpump_lownoisestart,9,0,1,18,1 "HP Module",heatpump,252,hpcurrpower,compressor current power,uint16 (>=0<=31999),W,false,sensor.heatpump_compressor_current_power,sensor.heatpump_hpcurrpower,9,0,1,18,1
"HP Module",heatpump,252,lownoisestop,low noise stoptime,uint8 (>=0<=23),hours,true,number.heatpump_low_noise_stoptime,number.heatpump_lownoisestop,9,0,1,19,1 "HP Module",heatpump,252,hybridstrategy,hybrid control strategy,enum [cost optimized\|co2 optimized\|outside temperature alt.\|outside temperature parallel\|heatpump preferred\|boiler only], ,true,select.heatpump_hybrid_control_strategy,select.heatpump_hybridstrategy,9,0,1,19,1
"HP Module",heatpump,252,lownoisemode,low noise mode,enum [off\|reduced output\|switch off hp\|perm. reduced], ,true,select.heatpump_low_noise_mode,select.heatpump_lownoisemode,9,0,1,20,1
"HP Module",heatpump,252,lownoisestart,low noise starttime,uint8 (>=0<=23),hours,true,number.heatpump_low_noise_starttime,number.heatpump_lownoisestart,9,0,1,21,1
"HP Module",heatpump,252,lownoisestop,low noise stoptime,uint8 (>=0<=23),hours,true,number.heatpump_low_noise_stoptime,number.heatpump_lownoisestop,9,0,1,22,1
"HP Module",heatpump,252,dhw.hybriddhw,hybrid DHW,enum [eco\|high comfort], ,true,select.heatpump_dhw_hybrid_DHW,select.heatpump_dhw_hybriddhw,9,9,1,0,1 "HP Module",heatpump,252,dhw.hybriddhw,hybrid DHW,enum [eco\|high comfort], ,true,select.heatpump_dhw_hybrid_DHW,select.heatpump_dhw_hybriddhw,9,9,1,0,1
"HP Module",heatpump,252,energypricegas,energy price gas,uint8 (>=0<=254),ct/kWh,true,number.heatpump_energy_price_gas,number.heatpump_energypricegas,9,0,1,20,1 "HP Module",heatpump,252,energypricegas,energy price gas,uint8 (>=0<=254),ct/kWh,true,number.heatpump_energy_price_gas,number.heatpump_energypricegas,9,0,1,23,1
"HP Module",heatpump,252,energypriceel,energy price electric,uint8 (>=0<=254),ct/kWh,true,number.heatpump_energy_price_electric,number.heatpump_energypriceel,9,0,1,21,1 "HP Module",heatpump,252,energypriceel,energy price electric,uint8 (>=0<=254),ct/kWh,true,number.heatpump_energy_price_electric,number.heatpump_energypriceel,9,0,1,24,1
"HP Module",heatpump,252,energyfeedpv,feed in PV,uint8 (>=0<=254),ct/kWh,true,number.heatpump_feed_in_PV,number.heatpump_energyfeedpv,9,0,1,22,1 "HP Module",heatpump,252,energyfeedpv,feed in PV,uint8 (>=0<=254),ct/kWh,true,number.heatpump_feed_in_PV,number.heatpump_energyfeedpv,9,0,1,25,1
"HP Module",heatpump,252,switchovertemp,outside switchover temperature,int8 (>=-126<=126),C,true,number.heatpump_outside_switchover_temperature,number.heatpump_switchovertemp,9,0,1,23,1 "HP Module",heatpump,252,switchovertemp,outside switchover temperature,int8 (>=-126<=126),C,true,number.heatpump_outside_switchover_temperature,number.heatpump_switchovertemp,9,0,1,26,1
"HP Module",heatpump,252,airpurgemode,air purge mode,boolean, ,true,switch.heatpump_air_purge_mode,switch.heatpump_airpurgemode,9,0,1,24,1 "HP Module",heatpump,252,airpurgemode,air purge mode,boolean, ,true,switch.heatpump_air_purge_mode,switch.heatpump_airpurgemode,9,0,1,27,1
"HP Module",heatpump,252,heatpumpoutput,heatpump output,uint8 (>=0<=100),%,true,number.heatpump_heatpump_output,number.heatpump_heatpumpoutput,9,0,1,25,1 "HP Module",heatpump,252,heatpumpoutput,heatpump output,uint8 (>=0<=100),%,true,number.heatpump_heatpump_output,number.heatpump_heatpumpoutput,9,0,1,28,1
"HP Module",heatpump,252,coolingcircuit,cooling circuit,boolean, ,true,switch.heatpump_cooling_circuit,switch.heatpump_coolingcircuit,9,0,1,26,1 "HP Module",heatpump,252,coolingcircuit,cooling circuit,boolean, ,true,switch.heatpump_cooling_circuit,switch.heatpump_coolingcircuit,9,0,1,29,1
"HP Module",heatpump,252,compstartmod,compressor start modulation,uint8 (>=0<=100),%,true,number.heatpump_compressor_start_modulation,number.heatpump_compstartmod,9,0,1,27,1 "HP Module",heatpump,252,compstartmod,compressor start modulation,uint8 (>=0<=100),%,true,number.heatpump_compressor_start_modulation,number.heatpump_compstartmod,9,0,1,30,1
"HP Module",heatpump,252,heatdrainpan,heat drain pan,boolean, ,true,switch.heatpump_heat_drain_pan,switch.heatpump_heatdrainpan,9,0,1,28,1 "HP Module",heatpump,252,heatdrainpan,heat drain pan,boolean, ,true,switch.heatpump_heat_drain_pan,switch.heatpump_heatdrainpan,9,0,1,31,1
"HP Module",heatpump,252,heatcable,heating cable,boolean, ,true,switch.heatpump_heating_cable,switch.heatpump_heatcable,9,0,1,29,1 "HP Module",heatpump,252,heatcable,heating cable,boolean, ,true,switch.heatpump_heating_cable,switch.heatpump_heatcable,9,0,1,32,1
"HP Module",heatpump,252,nrgtotal,total energy,uint24 (>=0<=167772),kWh,false,sensor.heatpump_total_energy,sensor.heatpump_nrgtotal,9,0,1/100,30,2 "HP Module",heatpump,252,nrgtotal,total energy,uint24 (>=0<=167772),kWh,false,sensor.heatpump_total_energy,sensor.heatpump_nrgtotal,9,0,1/100,33,2
"HP Module",heatpump,252,dhw.nrg,energy,uint24 (>=0<=167772),kWh,false,sensor.heatpump_dhw_energy,sensor.heatpump_dhw_nrg,9,9,1/100,1,2 "HP Module",heatpump,252,dhw.nrg,energy,uint24 (>=0<=167772),kWh,false,sensor.heatpump_dhw_energy,sensor.heatpump_dhw_nrg,9,9,1/100,1,2
"HP Module",heatpump,252,nrgheat,energy heating,uint24 (>=0<=167772),kWh,false,sensor.heatpump_energy_heating,sensor.heatpump_nrgheat,9,0,1/100,32,2 "HP Module",heatpump,252,nrgheat,energy heating,uint24 (>=0<=167772),kWh,false,sensor.heatpump_energy_heating,sensor.heatpump_nrgheat,9,0,1/100,35,2
"HP Module",heatpump,252,metertotal,meter total,uint24 (>=0<=167772),kWh,false,sensor.heatpump_meter_total,sensor.heatpump_metertotal,9,0,1/100,34,2 "HP Module",heatpump,252,metertotal,meter total,uint24 (>=0<=167772),kWh,false,sensor.heatpump_meter_total,sensor.heatpump_metertotal,9,0,1/100,37,2
"HP Module",heatpump,252,metercomp,meter compressor,uint24 (>=0<=167772),kWh,false,sensor.heatpump_meter_compressor,sensor.heatpump_metercomp,9,0,1/100,36,2 "HP Module",heatpump,252,metercomp,meter compressor,uint24 (>=0<=167772),kWh,false,sensor.heatpump_meter_compressor,sensor.heatpump_metercomp,9,0,1/100,39,2
"HP Module",heatpump,252,metereheat,meter e-heater,uint24 (>=0<=167772),kWh,false,sensor.heatpump_meter_e-heater,sensor.heatpump_metereheat,9,0,1/100,38,2 "HP Module",heatpump,252,metereheat,meter e-heater,uint24 (>=0<=167772),kWh,false,sensor.heatpump_meter_e-heater,sensor.heatpump_metereheat,9,0,1/100,41,2
"HP Module",heatpump,252,meterheat,meter heating,uint24 (>=0<=167772),kWh,false,sensor.heatpump_meter_heating,sensor.heatpump_meterheat,9,0,1/100,40,2 "HP Module",heatpump,252,meterheat,meter heating,uint24 (>=0<=167772),kWh,false,sensor.heatpump_meter_heating,sensor.heatpump_meterheat,9,0,1/100,43,2
"HP Module",heatpump,252,dhw.meter,meter,uint24 (>=0<=167772),kWh,false,sensor.heatpump_dhw_meter,sensor.heatpump_dhw_meter,9,9,1/100,3,2 "HP Module",heatpump,252,dhw.meter,meter,uint24 (>=0<=167772),kWh,false,sensor.heatpump_dhw_meter,sensor.heatpump_dhw_meter,9,9,1/100,3,2
"HP Module",heatpump,252,heatingstarts,heating control starts,uint24 (>=0<=16777214), ,false,sensor.heatpump_heating_control_starts,sensor.heatpump_heatingstarts,9,0,1,42,2 "HP Module",heatpump,252,heatingstarts,heating control starts,uint24 (>=0<=16777214), ,false,sensor.heatpump_heating_control_starts,sensor.heatpump_heatingstarts,9,0,1,45,2
"HP Module",heatpump,252,dhw.startshp,starts hp,uint24 (>=0<=16777214), ,false,sensor.heatpump_dhw_starts_hp,sensor.heatpump_dhw_startshp,9,9,1,5,2 "HP Module",heatpump,252,dhw.startshp,starts hp,uint24 (>=0<=16777214), ,false,sensor.heatpump_dhw_starts_hp,sensor.heatpump_dhw_startshp,9,9,1,5,2
"HP Module",heatpump,252,fuelheat,fuel consumption heating,uint32 (>=0<=1677721),kWh,false,sensor.heatpump_fuel_consumption_heating,sensor.heatpump_fuelheat,9,0,1/10,44,2 "HP Module",heatpump,252,fuelheat,fuel consumption heating,uint32 (>=0<=1677721),kWh,false,sensor.heatpump_fuel_consumption_heating,sensor.heatpump_fuelheat,9,0,1/10,47,2
"HP Module",heatpump,252,dhw.fueldhw,fuel consumption,uint32 (>=0<=1677721),kWh,false,sensor.heatpump_dhw_fuel_consumption,sensor.heatpump_dhw_fueldhw,9,9,1/10,7,2 "HP Module",heatpump,252,dhw.fueldhw,fuel consumption,uint32 (>=0<=1677721),kWh,false,sensor.heatpump_dhw_fuel_consumption,sensor.heatpump_dhw_fueldhw,9,9,1/10,7,2
"HP Module",heatpump,252,elheat,el. consumption heating,uint32 (>=0<=1677721),kWh,false,sensor.heatpump_el._consumption_heating,sensor.heatpump_elheat,9,0,1/10,46,2 "HP Module",heatpump,252,elheat,el. consumption heating,uint32 (>=0<=1677721),kWh,false,sensor.heatpump_el._consumption_heating,sensor.heatpump_elheat,9,0,1/10,49,2
"HP Module",heatpump,252,dhw.eldhw,el. consumption,uint32 (>=0<=1677721),kWh,false,sensor.heatpump_dhw_el._consumption,sensor.heatpump_dhw_eldhw,9,9,1/10,9,2 "HP Module",heatpump,252,dhw.eldhw,el. consumption,uint32 (>=0<=1677721),kWh,false,sensor.heatpump_dhw_el._consumption,sensor.heatpump_dhw_eldhw,9,9,1/10,9,2
"HP Module",heatpump,252,elgenheat,el. generation heating,uint32 (>=0<=1677721),kWh,false,sensor.heatpump_el._generation_heating,sensor.heatpump_elgenheat,9,0,1/10,48,2 "HP Module",heatpump,252,elgenheat,el. generation heating,uint32 (>=0<=1677721),kWh,false,sensor.heatpump_el._generation_heating,sensor.heatpump_elgenheat,9,0,1/10,51,2
"HP Module",heatpump,252,dhw.elgendhw,el generation,uint32 (>=0<=1677721),kWh,false,sensor.heatpump_dhw_el_generation,sensor.heatpump_dhw_elgendhw,9,9,1/10,11,2 "HP Module",heatpump,252,dhw.elgendhw,el generation,uint32 (>=0<=1677721),kWh,false,sensor.heatpump_dhw_el_generation,sensor.heatpump_dhw_elgendhw,9,9,1/10,11,2
"Hybrid Manager HM200",heatpump,248,airhumidity,relative air humidity,uint8 (>=0<=100),%,false,sensor.heatpump_relative_air_humidity,sensor.heatpump_airhumidity,9,0,1,0,1 "Hybrid Manager HM200",heatpump,248,airhumidity,relative air humidity,uint8 (>=0<=100),%,false,sensor.heatpump_relative_air_humidity,sensor.heatpump_airhumidity,9,0,1,0,1
"Hybrid Manager HM200",heatpump,248,dewtemperature,dew point temperature,uint8 (>=0<=254),C,false,sensor.heatpump_dew_point_temperature,sensor.heatpump_dewtemperature,9,0,1,1,1 "Hybrid Manager HM200",heatpump,248,dewtemperature,dew point temperature,uint8 (>=0<=254),C,false,sensor.heatpump_dew_point_temperature,sensor.heatpump_dewtemperature,9,0,1,1,1
@@ -5656,36 +5659,39 @@ device name,device type,product id,shortname,fullname,type [options...] \| (min/
"Hybrid Manager HM200",heatpump,248,hpph1,high pressure side temperature (PH1),int16 (>=-3199<=3199),C,false,sensor.heatpump_high_pressure_side_temperature_(PH1),sensor.heatpump_hpph1,9,0,1/10,13,1 "Hybrid Manager HM200",heatpump,248,hpph1,high pressure side temperature (PH1),int16 (>=-3199<=3199),C,false,sensor.heatpump_high_pressure_side_temperature_(PH1),sensor.heatpump_hpph1,9,0,1/10,13,1
"Hybrid Manager HM200",heatpump,248,heatingpumpmod,heating pump modulation,uint8 (>=0<=100),%,false,sensor.heatpump_heating_pump_modulation,sensor.heatpump_heatingpumpmod,9,0,1,14,1 "Hybrid Manager HM200",heatpump,248,heatingpumpmod,heating pump modulation,uint8 (>=0<=100),%,false,sensor.heatpump_heating_pump_modulation,sensor.heatpump_heatingpumpmod,9,0,1,14,1
"Hybrid Manager HM200",heatpump,248,hpcompspd,compressor speed,uint8 (>=0<=100),%,false,sensor.heatpump_compressor_speed,sensor.heatpump_hpcompspd,9,0,1,15,1 "Hybrid Manager HM200",heatpump,248,hpcompspd,compressor speed,uint8 (>=0<=100),%,false,sensor.heatpump_compressor_speed,sensor.heatpump_hpcompspd,9,0,1,15,1
"Hybrid Manager HM200",heatpump,248,hybridstrategy,hybrid control strategy,enum [cost optimized\|co2 optimized\|outside temperature alt.\|outside temperature parallel\|heatpump preferred\|boiler only], ,true,select.heatpump_hybrid_control_strategy,select.heatpump_hybridstrategy,9,0,1,16,1 "Hybrid Manager HM200",heatpump,248,hpactivity,compressor activity,enum [off\|heating\|hot water\|defrost\|compressor alarm], ,false,sensor.heatpump_compressor_activity,sensor.heatpump_hpactivity,9,0,1,16,1
"Hybrid Manager HM200",heatpump,248,lownoisemode,low noise mode,enum [off\|reduced output\|switch off hp\|perm. reduced], ,true,select.heatpump_low_noise_mode,select.heatpump_lownoisemode,9,0,1,17,1 "Hybrid Manager HM200",heatpump,248,hppower,compressor power output,uint16 (>=0<=31999),W,false,sensor.heatpump_compressor_power_output,sensor.heatpump_hppower,9,0,1,17,1
"Hybrid Manager HM200",heatpump,248,lownoisestart,low noise starttime,uint8 (>=0<=23),hours,true,number.heatpump_low_noise_starttime,number.heatpump_lownoisestart,9,0,1,18,1 "Hybrid Manager HM200",heatpump,248,hpcurrpower,compressor current power,uint16 (>=0<=31999),W,false,sensor.heatpump_compressor_current_power,sensor.heatpump_hpcurrpower,9,0,1,18,1
"Hybrid Manager HM200",heatpump,248,lownoisestop,low noise stoptime,uint8 (>=0<=23),hours,true,number.heatpump_low_noise_stoptime,number.heatpump_lownoisestop,9,0,1,19,1 "Hybrid Manager HM200",heatpump,248,hybridstrategy,hybrid control strategy,enum [cost optimized\|co2 optimized\|outside temperature alt.\|outside temperature parallel\|heatpump preferred\|boiler only], ,true,select.heatpump_hybrid_control_strategy,select.heatpump_hybridstrategy,9,0,1,19,1
"Hybrid Manager HM200",heatpump,248,lownoisemode,low noise mode,enum [off\|reduced output\|switch off hp\|perm. reduced], ,true,select.heatpump_low_noise_mode,select.heatpump_lownoisemode,9,0,1,20,1
"Hybrid Manager HM200",heatpump,248,lownoisestart,low noise starttime,uint8 (>=0<=23),hours,true,number.heatpump_low_noise_starttime,number.heatpump_lownoisestart,9,0,1,21,1
"Hybrid Manager HM200",heatpump,248,lownoisestop,low noise stoptime,uint8 (>=0<=23),hours,true,number.heatpump_low_noise_stoptime,number.heatpump_lownoisestop,9,0,1,22,1
"Hybrid Manager HM200",heatpump,248,dhw.hybriddhw,hybrid DHW,enum [eco\|high comfort], ,true,select.heatpump_dhw_hybrid_DHW,select.heatpump_dhw_hybriddhw,9,9,1,0,1 "Hybrid Manager HM200",heatpump,248,dhw.hybriddhw,hybrid DHW,enum [eco\|high comfort], ,true,select.heatpump_dhw_hybrid_DHW,select.heatpump_dhw_hybriddhw,9,9,1,0,1
"Hybrid Manager HM200",heatpump,248,energypricegas,energy price gas,uint8 (>=0<=254),ct/kWh,true,number.heatpump_energy_price_gas,number.heatpump_energypricegas,9,0,1,20,1 "Hybrid Manager HM200",heatpump,248,energypricegas,energy price gas,uint8 (>=0<=254),ct/kWh,true,number.heatpump_energy_price_gas,number.heatpump_energypricegas,9,0,1,23,1
"Hybrid Manager HM200",heatpump,248,energypriceel,energy price electric,uint8 (>=0<=254),ct/kWh,true,number.heatpump_energy_price_electric,number.heatpump_energypriceel,9,0,1,21,1 "Hybrid Manager HM200",heatpump,248,energypriceel,energy price electric,uint8 (>=0<=254),ct/kWh,true,number.heatpump_energy_price_electric,number.heatpump_energypriceel,9,0,1,24,1
"Hybrid Manager HM200",heatpump,248,energyfeedpv,feed in PV,uint8 (>=0<=254),ct/kWh,true,number.heatpump_feed_in_PV,number.heatpump_energyfeedpv,9,0,1,22,1 "Hybrid Manager HM200",heatpump,248,energyfeedpv,feed in PV,uint8 (>=0<=254),ct/kWh,true,number.heatpump_feed_in_PV,number.heatpump_energyfeedpv,9,0,1,25,1
"Hybrid Manager HM200",heatpump,248,switchovertemp,outside switchover temperature,int8 (>=-126<=126),C,true,number.heatpump_outside_switchover_temperature,number.heatpump_switchovertemp,9,0,1,23,1 "Hybrid Manager HM200",heatpump,248,switchovertemp,outside switchover temperature,int8 (>=-126<=126),C,true,number.heatpump_outside_switchover_temperature,number.heatpump_switchovertemp,9,0,1,26,1
"Hybrid Manager HM200",heatpump,248,airpurgemode,air purge mode,boolean, ,true,switch.heatpump_air_purge_mode,switch.heatpump_airpurgemode,9,0,1,24,1 "Hybrid Manager HM200",heatpump,248,airpurgemode,air purge mode,boolean, ,true,switch.heatpump_air_purge_mode,switch.heatpump_airpurgemode,9,0,1,27,1
"Hybrid Manager HM200",heatpump,248,heatpumpoutput,heatpump output,uint8 (>=0<=100),%,true,number.heatpump_heatpump_output,number.heatpump_heatpumpoutput,9,0,1,25,1 "Hybrid Manager HM200",heatpump,248,heatpumpoutput,heatpump output,uint8 (>=0<=100),%,true,number.heatpump_heatpump_output,number.heatpump_heatpumpoutput,9,0,1,28,1
"Hybrid Manager HM200",heatpump,248,coolingcircuit,cooling circuit,boolean, ,true,switch.heatpump_cooling_circuit,switch.heatpump_coolingcircuit,9,0,1,26,1 "Hybrid Manager HM200",heatpump,248,coolingcircuit,cooling circuit,boolean, ,true,switch.heatpump_cooling_circuit,switch.heatpump_coolingcircuit,9,0,1,29,1
"Hybrid Manager HM200",heatpump,248,compstartmod,compressor start modulation,uint8 (>=0<=100),%,true,number.heatpump_compressor_start_modulation,number.heatpump_compstartmod,9,0,1,27,1 "Hybrid Manager HM200",heatpump,248,compstartmod,compressor start modulation,uint8 (>=0<=100),%,true,number.heatpump_compressor_start_modulation,number.heatpump_compstartmod,9,0,1,30,1
"Hybrid Manager HM200",heatpump,248,heatdrainpan,heat drain pan,boolean, ,true,switch.heatpump_heat_drain_pan,switch.heatpump_heatdrainpan,9,0,1,28,1 "Hybrid Manager HM200",heatpump,248,heatdrainpan,heat drain pan,boolean, ,true,switch.heatpump_heat_drain_pan,switch.heatpump_heatdrainpan,9,0,1,31,1
"Hybrid Manager HM200",heatpump,248,heatcable,heating cable,boolean, ,true,switch.heatpump_heating_cable,switch.heatpump_heatcable,9,0,1,29,1 "Hybrid Manager HM200",heatpump,248,heatcable,heating cable,boolean, ,true,switch.heatpump_heating_cable,switch.heatpump_heatcable,9,0,1,32,1
"Hybrid Manager HM200",heatpump,248,nrgtotal,total energy,uint24 (>=0<=167772),kWh,false,sensor.heatpump_total_energy,sensor.heatpump_nrgtotal,9,0,1/100,30,2 "Hybrid Manager HM200",heatpump,248,nrgtotal,total energy,uint24 (>=0<=167772),kWh,false,sensor.heatpump_total_energy,sensor.heatpump_nrgtotal,9,0,1/100,33,2
"Hybrid Manager HM200",heatpump,248,dhw.nrg,energy,uint24 (>=0<=167772),kWh,false,sensor.heatpump_dhw_energy,sensor.heatpump_dhw_nrg,9,9,1/100,1,2 "Hybrid Manager HM200",heatpump,248,dhw.nrg,energy,uint24 (>=0<=167772),kWh,false,sensor.heatpump_dhw_energy,sensor.heatpump_dhw_nrg,9,9,1/100,1,2
"Hybrid Manager HM200",heatpump,248,nrgheat,energy heating,uint24 (>=0<=167772),kWh,false,sensor.heatpump_energy_heating,sensor.heatpump_nrgheat,9,0,1/100,32,2 "Hybrid Manager HM200",heatpump,248,nrgheat,energy heating,uint24 (>=0<=167772),kWh,false,sensor.heatpump_energy_heating,sensor.heatpump_nrgheat,9,0,1/100,35,2
"Hybrid Manager HM200",heatpump,248,metertotal,meter total,uint24 (>=0<=167772),kWh,false,sensor.heatpump_meter_total,sensor.heatpump_metertotal,9,0,1/100,34,2 "Hybrid Manager HM200",heatpump,248,metertotal,meter total,uint24 (>=0<=167772),kWh,false,sensor.heatpump_meter_total,sensor.heatpump_metertotal,9,0,1/100,37,2
"Hybrid Manager HM200",heatpump,248,metercomp,meter compressor,uint24 (>=0<=167772),kWh,false,sensor.heatpump_meter_compressor,sensor.heatpump_metercomp,9,0,1/100,36,2 "Hybrid Manager HM200",heatpump,248,metercomp,meter compressor,uint24 (>=0<=167772),kWh,false,sensor.heatpump_meter_compressor,sensor.heatpump_metercomp,9,0,1/100,39,2
"Hybrid Manager HM200",heatpump,248,metereheat,meter e-heater,uint24 (>=0<=167772),kWh,false,sensor.heatpump_meter_e-heater,sensor.heatpump_metereheat,9,0,1/100,38,2 "Hybrid Manager HM200",heatpump,248,metereheat,meter e-heater,uint24 (>=0<=167772),kWh,false,sensor.heatpump_meter_e-heater,sensor.heatpump_metereheat,9,0,1/100,41,2
"Hybrid Manager HM200",heatpump,248,meterheat,meter heating,uint24 (>=0<=167772),kWh,false,sensor.heatpump_meter_heating,sensor.heatpump_meterheat,9,0,1/100,40,2 "Hybrid Manager HM200",heatpump,248,meterheat,meter heating,uint24 (>=0<=167772),kWh,false,sensor.heatpump_meter_heating,sensor.heatpump_meterheat,9,0,1/100,43,2
"Hybrid Manager HM200",heatpump,248,dhw.meter,meter,uint24 (>=0<=167772),kWh,false,sensor.heatpump_dhw_meter,sensor.heatpump_dhw_meter,9,9,1/100,3,2 "Hybrid Manager HM200",heatpump,248,dhw.meter,meter,uint24 (>=0<=167772),kWh,false,sensor.heatpump_dhw_meter,sensor.heatpump_dhw_meter,9,9,1/100,3,2
"Hybrid Manager HM200",heatpump,248,heatingstarts,heating control starts,uint24 (>=0<=16777214), ,false,sensor.heatpump_heating_control_starts,sensor.heatpump_heatingstarts,9,0,1,42,2 "Hybrid Manager HM200",heatpump,248,heatingstarts,heating control starts,uint24 (>=0<=16777214), ,false,sensor.heatpump_heating_control_starts,sensor.heatpump_heatingstarts,9,0,1,45,2
"Hybrid Manager HM200",heatpump,248,dhw.startshp,starts hp,uint24 (>=0<=16777214), ,false,sensor.heatpump_dhw_starts_hp,sensor.heatpump_dhw_startshp,9,9,1,5,2 "Hybrid Manager HM200",heatpump,248,dhw.startshp,starts hp,uint24 (>=0<=16777214), ,false,sensor.heatpump_dhw_starts_hp,sensor.heatpump_dhw_startshp,9,9,1,5,2
"Hybrid Manager HM200",heatpump,248,fuelheat,fuel consumption heating,uint32 (>=0<=1677721),kWh,false,sensor.heatpump_fuel_consumption_heating,sensor.heatpump_fuelheat,9,0,1/10,44,2 "Hybrid Manager HM200",heatpump,248,fuelheat,fuel consumption heating,uint32 (>=0<=1677721),kWh,false,sensor.heatpump_fuel_consumption_heating,sensor.heatpump_fuelheat,9,0,1/10,47,2
"Hybrid Manager HM200",heatpump,248,dhw.fueldhw,fuel consumption,uint32 (>=0<=1677721),kWh,false,sensor.heatpump_dhw_fuel_consumption,sensor.heatpump_dhw_fueldhw,9,9,1/10,7,2 "Hybrid Manager HM200",heatpump,248,dhw.fueldhw,fuel consumption,uint32 (>=0<=1677721),kWh,false,sensor.heatpump_dhw_fuel_consumption,sensor.heatpump_dhw_fueldhw,9,9,1/10,7,2
"Hybrid Manager HM200",heatpump,248,elheat,el. consumption heating,uint32 (>=0<=1677721),kWh,false,sensor.heatpump_el._consumption_heating,sensor.heatpump_elheat,9,0,1/10,46,2 "Hybrid Manager HM200",heatpump,248,elheat,el. consumption heating,uint32 (>=0<=1677721),kWh,false,sensor.heatpump_el._consumption_heating,sensor.heatpump_elheat,9,0,1/10,49,2
"Hybrid Manager HM200",heatpump,248,dhw.eldhw,el. consumption,uint32 (>=0<=1677721),kWh,false,sensor.heatpump_dhw_el._consumption,sensor.heatpump_dhw_eldhw,9,9,1/10,9,2 "Hybrid Manager HM200",heatpump,248,dhw.eldhw,el. consumption,uint32 (>=0<=1677721),kWh,false,sensor.heatpump_dhw_el._consumption,sensor.heatpump_dhw_eldhw,9,9,1/10,9,2
"Hybrid Manager HM200",heatpump,248,elgenheat,el. generation heating,uint32 (>=0<=1677721),kWh,false,sensor.heatpump_el._generation_heating,sensor.heatpump_elgenheat,9,0,1/10,48,2 "Hybrid Manager HM200",heatpump,248,elgenheat,el. generation heating,uint32 (>=0<=1677721),kWh,false,sensor.heatpump_el._generation_heating,sensor.heatpump_elgenheat,9,0,1/10,51,2
"Hybrid Manager HM200",heatpump,248,dhw.elgendhw,el generation,uint32 (>=0<=1677721),kWh,false,sensor.heatpump_dhw_el_generation,sensor.heatpump_dhw_elgendhw,9,9,1/10,11,2 "Hybrid Manager HM200",heatpump,248,dhw.elgendhw,el generation,uint32 (>=0<=1677721),kWh,false,sensor.heatpump_dhw_el_generation,sensor.heatpump_dhw_elgendhw,9,9,1/10,11,2
"CSH5800iG",heatpump,16,airhumidity,relative air humidity,uint8 (>=0<=100),%,false,sensor.heatpump_relative_air_humidity,sensor.heatpump_airhumidity,9,0,1,0,1 "CSH5800iG",heatpump,16,airhumidity,relative air humidity,uint8 (>=0<=100),%,false,sensor.heatpump_relative_air_humidity,sensor.heatpump_airhumidity,9,0,1,0,1
"CSH5800iG",heatpump,16,dewtemperature,dew point temperature,uint8 (>=0<=254),C,false,sensor.heatpump_dew_point_temperature,sensor.heatpump_dewtemperature,9,0,1,1,1 "CSH5800iG",heatpump,16,dewtemperature,dew point temperature,uint8 (>=0<=254),C,false,sensor.heatpump_dew_point_temperature,sensor.heatpump_dewtemperature,9,0,1,1,1
@@ -5703,36 +5709,39 @@ device name,device type,product id,shortname,fullname,type [options...] \| (min/
"CSH5800iG",heatpump,16,hpph1,high pressure side temperature (PH1),int16 (>=-3199<=3199),C,false,sensor.heatpump_high_pressure_side_temperature_(PH1),sensor.heatpump_hpph1,9,0,1/10,13,1 "CSH5800iG",heatpump,16,hpph1,high pressure side temperature (PH1),int16 (>=-3199<=3199),C,false,sensor.heatpump_high_pressure_side_temperature_(PH1),sensor.heatpump_hpph1,9,0,1/10,13,1
"CSH5800iG",heatpump,16,heatingpumpmod,heating pump modulation,uint8 (>=0<=100),%,false,sensor.heatpump_heating_pump_modulation,sensor.heatpump_heatingpumpmod,9,0,1,14,1 "CSH5800iG",heatpump,16,heatingpumpmod,heating pump modulation,uint8 (>=0<=100),%,false,sensor.heatpump_heating_pump_modulation,sensor.heatpump_heatingpumpmod,9,0,1,14,1
"CSH5800iG",heatpump,16,hpcompspd,compressor speed,uint8 (>=0<=100),%,false,sensor.heatpump_compressor_speed,sensor.heatpump_hpcompspd,9,0,1,15,1 "CSH5800iG",heatpump,16,hpcompspd,compressor speed,uint8 (>=0<=100),%,false,sensor.heatpump_compressor_speed,sensor.heatpump_hpcompspd,9,0,1,15,1
"CSH5800iG",heatpump,16,hybridstrategy,hybrid control strategy,enum [cost optimized\|co2 optimized\|outside temperature alt.\|outside temperature parallel\|heatpump preferred\|boiler only], ,true,select.heatpump_hybrid_control_strategy,select.heatpump_hybridstrategy,9,0,1,16,1 "CSH5800iG",heatpump,16,hpactivity,compressor activity,enum [off\|heating\|hot water\|defrost\|compressor alarm], ,false,sensor.heatpump_compressor_activity,sensor.heatpump_hpactivity,9,0,1,16,1
"CSH5800iG",heatpump,16,lownoisemode,low noise mode,enum [off\|reduced output\|switch off hp\|perm. reduced], ,true,select.heatpump_low_noise_mode,select.heatpump_lownoisemode,9,0,1,17,1 "CSH5800iG",heatpump,16,hppower,compressor power output,uint16 (>=0<=31999),W,false,sensor.heatpump_compressor_power_output,sensor.heatpump_hppower,9,0,1,17,1
"CSH5800iG",heatpump,16,lownoisestart,low noise starttime,uint8 (>=0<=23),hours,true,number.heatpump_low_noise_starttime,number.heatpump_lownoisestart,9,0,1,18,1 "CSH5800iG",heatpump,16,hpcurrpower,compressor current power,uint16 (>=0<=31999),W,false,sensor.heatpump_compressor_current_power,sensor.heatpump_hpcurrpower,9,0,1,18,1
"CSH5800iG",heatpump,16,lownoisestop,low noise stoptime,uint8 (>=0<=23),hours,true,number.heatpump_low_noise_stoptime,number.heatpump_lownoisestop,9,0,1,19,1 "CSH5800iG",heatpump,16,hybridstrategy,hybrid control strategy,enum [cost optimized\|co2 optimized\|outside temperature alt.\|outside temperature parallel\|heatpump preferred\|boiler only], ,true,select.heatpump_hybrid_control_strategy,select.heatpump_hybridstrategy,9,0,1,19,1
"CSH5800iG",heatpump,16,lownoisemode,low noise mode,enum [off\|reduced output\|switch off hp\|perm. reduced], ,true,select.heatpump_low_noise_mode,select.heatpump_lownoisemode,9,0,1,20,1
"CSH5800iG",heatpump,16,lownoisestart,low noise starttime,uint8 (>=0<=23),hours,true,number.heatpump_low_noise_starttime,number.heatpump_lownoisestart,9,0,1,21,1
"CSH5800iG",heatpump,16,lownoisestop,low noise stoptime,uint8 (>=0<=23),hours,true,number.heatpump_low_noise_stoptime,number.heatpump_lownoisestop,9,0,1,22,1
"CSH5800iG",heatpump,16,dhw.hybriddhw,hybrid DHW,enum [eco\|high comfort], ,true,select.heatpump_dhw_hybrid_DHW,select.heatpump_dhw_hybriddhw,9,9,1,0,1 "CSH5800iG",heatpump,16,dhw.hybriddhw,hybrid DHW,enum [eco\|high comfort], ,true,select.heatpump_dhw_hybrid_DHW,select.heatpump_dhw_hybriddhw,9,9,1,0,1
"CSH5800iG",heatpump,16,energypricegas,energy price gas,uint8 (>=0<=254),ct/kWh,true,number.heatpump_energy_price_gas,number.heatpump_energypricegas,9,0,1,20,1 "CSH5800iG",heatpump,16,energypricegas,energy price gas,uint8 (>=0<=254),ct/kWh,true,number.heatpump_energy_price_gas,number.heatpump_energypricegas,9,0,1,23,1
"CSH5800iG",heatpump,16,energypriceel,energy price electric,uint8 (>=0<=254),ct/kWh,true,number.heatpump_energy_price_electric,number.heatpump_energypriceel,9,0,1,21,1 "CSH5800iG",heatpump,16,energypriceel,energy price electric,uint8 (>=0<=254),ct/kWh,true,number.heatpump_energy_price_electric,number.heatpump_energypriceel,9,0,1,24,1
"CSH5800iG",heatpump,16,energyfeedpv,feed in PV,uint8 (>=0<=254),ct/kWh,true,number.heatpump_feed_in_PV,number.heatpump_energyfeedpv,9,0,1,22,1 "CSH5800iG",heatpump,16,energyfeedpv,feed in PV,uint8 (>=0<=254),ct/kWh,true,number.heatpump_feed_in_PV,number.heatpump_energyfeedpv,9,0,1,25,1
"CSH5800iG",heatpump,16,switchovertemp,outside switchover temperature,int8 (>=-126<=126),C,true,number.heatpump_outside_switchover_temperature,number.heatpump_switchovertemp,9,0,1,23,1 "CSH5800iG",heatpump,16,switchovertemp,outside switchover temperature,int8 (>=-126<=126),C,true,number.heatpump_outside_switchover_temperature,number.heatpump_switchovertemp,9,0,1,26,1
"CSH5800iG",heatpump,16,airpurgemode,air purge mode,boolean, ,true,switch.heatpump_air_purge_mode,switch.heatpump_airpurgemode,9,0,1,24,1 "CSH5800iG",heatpump,16,airpurgemode,air purge mode,boolean, ,true,switch.heatpump_air_purge_mode,switch.heatpump_airpurgemode,9,0,1,27,1
"CSH5800iG",heatpump,16,heatpumpoutput,heatpump output,uint8 (>=0<=100),%,true,number.heatpump_heatpump_output,number.heatpump_heatpumpoutput,9,0,1,25,1 "CSH5800iG",heatpump,16,heatpumpoutput,heatpump output,uint8 (>=0<=100),%,true,number.heatpump_heatpump_output,number.heatpump_heatpumpoutput,9,0,1,28,1
"CSH5800iG",heatpump,16,coolingcircuit,cooling circuit,boolean, ,true,switch.heatpump_cooling_circuit,switch.heatpump_coolingcircuit,9,0,1,26,1 "CSH5800iG",heatpump,16,coolingcircuit,cooling circuit,boolean, ,true,switch.heatpump_cooling_circuit,switch.heatpump_coolingcircuit,9,0,1,29,1
"CSH5800iG",heatpump,16,compstartmod,compressor start modulation,uint8 (>=0<=100),%,true,number.heatpump_compressor_start_modulation,number.heatpump_compstartmod,9,0,1,27,1 "CSH5800iG",heatpump,16,compstartmod,compressor start modulation,uint8 (>=0<=100),%,true,number.heatpump_compressor_start_modulation,number.heatpump_compstartmod,9,0,1,30,1
"CSH5800iG",heatpump,16,heatdrainpan,heat drain pan,boolean, ,true,switch.heatpump_heat_drain_pan,switch.heatpump_heatdrainpan,9,0,1,28,1 "CSH5800iG",heatpump,16,heatdrainpan,heat drain pan,boolean, ,true,switch.heatpump_heat_drain_pan,switch.heatpump_heatdrainpan,9,0,1,31,1
"CSH5800iG",heatpump,16,heatcable,heating cable,boolean, ,true,switch.heatpump_heating_cable,switch.heatpump_heatcable,9,0,1,29,1 "CSH5800iG",heatpump,16,heatcable,heating cable,boolean, ,true,switch.heatpump_heating_cable,switch.heatpump_heatcable,9,0,1,32,1
"CSH5800iG",heatpump,16,nrgtotal,total energy,uint24 (>=0<=167772),kWh,false,sensor.heatpump_total_energy,sensor.heatpump_nrgtotal,9,0,1/100,30,2 "CSH5800iG",heatpump,16,nrgtotal,total energy,uint24 (>=0<=167772),kWh,false,sensor.heatpump_total_energy,sensor.heatpump_nrgtotal,9,0,1/100,33,2
"CSH5800iG",heatpump,16,dhw.nrg,energy,uint24 (>=0<=167772),kWh,false,sensor.heatpump_dhw_energy,sensor.heatpump_dhw_nrg,9,9,1/100,1,2 "CSH5800iG",heatpump,16,dhw.nrg,energy,uint24 (>=0<=167772),kWh,false,sensor.heatpump_dhw_energy,sensor.heatpump_dhw_nrg,9,9,1/100,1,2
"CSH5800iG",heatpump,16,nrgheat,energy heating,uint24 (>=0<=167772),kWh,false,sensor.heatpump_energy_heating,sensor.heatpump_nrgheat,9,0,1/100,32,2 "CSH5800iG",heatpump,16,nrgheat,energy heating,uint24 (>=0<=167772),kWh,false,sensor.heatpump_energy_heating,sensor.heatpump_nrgheat,9,0,1/100,35,2
"CSH5800iG",heatpump,16,metertotal,meter total,uint24 (>=0<=167772),kWh,false,sensor.heatpump_meter_total,sensor.heatpump_metertotal,9,0,1/100,34,2 "CSH5800iG",heatpump,16,metertotal,meter total,uint24 (>=0<=167772),kWh,false,sensor.heatpump_meter_total,sensor.heatpump_metertotal,9,0,1/100,37,2
"CSH5800iG",heatpump,16,metercomp,meter compressor,uint24 (>=0<=167772),kWh,false,sensor.heatpump_meter_compressor,sensor.heatpump_metercomp,9,0,1/100,36,2 "CSH5800iG",heatpump,16,metercomp,meter compressor,uint24 (>=0<=167772),kWh,false,sensor.heatpump_meter_compressor,sensor.heatpump_metercomp,9,0,1/100,39,2
"CSH5800iG",heatpump,16,metereheat,meter e-heater,uint24 (>=0<=167772),kWh,false,sensor.heatpump_meter_e-heater,sensor.heatpump_metereheat,9,0,1/100,38,2 "CSH5800iG",heatpump,16,metereheat,meter e-heater,uint24 (>=0<=167772),kWh,false,sensor.heatpump_meter_e-heater,sensor.heatpump_metereheat,9,0,1/100,41,2
"CSH5800iG",heatpump,16,meterheat,meter heating,uint24 (>=0<=167772),kWh,false,sensor.heatpump_meter_heating,sensor.heatpump_meterheat,9,0,1/100,40,2 "CSH5800iG",heatpump,16,meterheat,meter heating,uint24 (>=0<=167772),kWh,false,sensor.heatpump_meter_heating,sensor.heatpump_meterheat,9,0,1/100,43,2
"CSH5800iG",heatpump,16,dhw.meter,meter,uint24 (>=0<=167772),kWh,false,sensor.heatpump_dhw_meter,sensor.heatpump_dhw_meter,9,9,1/100,3,2 "CSH5800iG",heatpump,16,dhw.meter,meter,uint24 (>=0<=167772),kWh,false,sensor.heatpump_dhw_meter,sensor.heatpump_dhw_meter,9,9,1/100,3,2
"CSH5800iG",heatpump,16,heatingstarts,heating control starts,uint24 (>=0<=16777214), ,false,sensor.heatpump_heating_control_starts,sensor.heatpump_heatingstarts,9,0,1,42,2 "CSH5800iG",heatpump,16,heatingstarts,heating control starts,uint24 (>=0<=16777214), ,false,sensor.heatpump_heating_control_starts,sensor.heatpump_heatingstarts,9,0,1,45,2
"CSH5800iG",heatpump,16,dhw.startshp,starts hp,uint24 (>=0<=16777214), ,false,sensor.heatpump_dhw_starts_hp,sensor.heatpump_dhw_startshp,9,9,1,5,2 "CSH5800iG",heatpump,16,dhw.startshp,starts hp,uint24 (>=0<=16777214), ,false,sensor.heatpump_dhw_starts_hp,sensor.heatpump_dhw_startshp,9,9,1,5,2
"CSH5800iG",heatpump,16,fuelheat,fuel consumption heating,uint32 (>=0<=1677721),kWh,false,sensor.heatpump_fuel_consumption_heating,sensor.heatpump_fuelheat,9,0,1/10,44,2 "CSH5800iG",heatpump,16,fuelheat,fuel consumption heating,uint32 (>=0<=1677721),kWh,false,sensor.heatpump_fuel_consumption_heating,sensor.heatpump_fuelheat,9,0,1/10,47,2
"CSH5800iG",heatpump,16,dhw.fueldhw,fuel consumption,uint32 (>=0<=1677721),kWh,false,sensor.heatpump_dhw_fuel_consumption,sensor.heatpump_dhw_fueldhw,9,9,1/10,7,2 "CSH5800iG",heatpump,16,dhw.fueldhw,fuel consumption,uint32 (>=0<=1677721),kWh,false,sensor.heatpump_dhw_fuel_consumption,sensor.heatpump_dhw_fueldhw,9,9,1/10,7,2
"CSH5800iG",heatpump,16,elheat,el. consumption heating,uint32 (>=0<=1677721),kWh,false,sensor.heatpump_el._consumption_heating,sensor.heatpump_elheat,9,0,1/10,46,2 "CSH5800iG",heatpump,16,elheat,el. consumption heating,uint32 (>=0<=1677721),kWh,false,sensor.heatpump_el._consumption_heating,sensor.heatpump_elheat,9,0,1/10,49,2
"CSH5800iG",heatpump,16,dhw.eldhw,el. consumption,uint32 (>=0<=1677721),kWh,false,sensor.heatpump_dhw_el._consumption,sensor.heatpump_dhw_eldhw,9,9,1/10,9,2 "CSH5800iG",heatpump,16,dhw.eldhw,el. consumption,uint32 (>=0<=1677721),kWh,false,sensor.heatpump_dhw_el._consumption,sensor.heatpump_dhw_eldhw,9,9,1/10,9,2
"CSH5800iG",heatpump,16,elgenheat,el. generation heating,uint32 (>=0<=1677721),kWh,false,sensor.heatpump_el._generation_heating,sensor.heatpump_elgenheat,9,0,1/10,48,2 "CSH5800iG",heatpump,16,elgenheat,el. generation heating,uint32 (>=0<=1677721),kWh,false,sensor.heatpump_el._generation_heating,sensor.heatpump_elgenheat,9,0,1/10,51,2
"CSH5800iG",heatpump,16,dhw.elgendhw,el generation,uint32 (>=0<=1677721),kWh,false,sensor.heatpump_dhw_el_generation,sensor.heatpump_dhw_elgendhw,9,9,1/10,11,2 "CSH5800iG",heatpump,16,dhw.elgendhw,el generation,uint32 (>=0<=1677721),kWh,false,sensor.heatpump_dhw_el_generation,sensor.heatpump_dhw_elgendhw,9,9,1/10,11,2
"WM10",switch,71,activated,activated,boolean, ,false,binary_sensor.switch_activated,binary_sensor.switch_activated,11,0,1,0,1 "WM10",switch,71,activated,activated,boolean, ,false,binary_sensor.switch_activated,binary_sensor.switch_activated,11,0,1,0,1
"WM10",switch,71,flowtemphc,flow temperature (TC1),uint16 (>=0<=3199),C,false,sensor.switch_flow_temperature_(TC1),sensor.switch_flowtemphc,11,0,1/10,1,1 "WM10",switch,71,flowtemphc,flow temperature (TC1),uint16 (>=0<=3199),C,false,sensor.switch_flow_temperature_(TC1),sensor.switch_flowtemphc,11,0,1/10,1,1
Can't render this file because it is too large.

View File

@@ -111,10 +111,10 @@ telegram_type_id,name,is_fetched
0x02A0,RC300Curves, 0x02A0,RC300Curves,
0x02A1,RC300Curves, 0x02A1,RC300Curves,
0x02A2,RC300Curves, 0x02A2,RC300Curves,
0x02A5,RC300Monitor,fetched 0x02A5,RC300Monitor,
0x02A6,RC300Monitor, 0x02A6,RC300Monitor,
0x02A7,RC300Monitor, 0x02A7,RC300Monitor,
0x02A8,RC300Monitor, 0x02A8,CRFMonitor,
0x02A9,RC300Monitor, 0x02A9,RC300Monitor,
0x02AA,RC300Monitor, 0x02AA,RC300Monitor,
0x02AB,RC300Monitor, 0x02AB,RC300Monitor,
1 telegram_type_id name is_fetched
111 0x02A0 RC300Curves
112 0x02A1 RC300Curves
113 0x02A2 RC300Curves
114 0x02A5 RC300Monitor fetched
115 0x02A6 RC300Monitor
116 0x02A7 RC300Monitor
117 0x02A8 RC300Monitor CRFMonitor
118 0x02A9 RC300Monitor
119 0x02AA RC300Monitor
120 0x02AB RC300Monitor

View File

@@ -504,30 +504,33 @@ const std::initializer_list<Modbus::EntityModbusInfo> Modbus::modbus_register_ma
REGISTER_MAPPING(dt::HEATPUMP, TAG_TYPE_DEVICE_DATA, FL_(hpPh1), 13, 1), // hpph1 REGISTER_MAPPING(dt::HEATPUMP, TAG_TYPE_DEVICE_DATA, FL_(hpPh1), 13, 1), // hpph1
REGISTER_MAPPING(dt::HEATPUMP, TAG_TYPE_DEVICE_DATA, FL_(heatingPumpMod), 14, 1), // heatingpumpmod REGISTER_MAPPING(dt::HEATPUMP, TAG_TYPE_DEVICE_DATA, FL_(heatingPumpMod), 14, 1), // heatingpumpmod
REGISTER_MAPPING(dt::HEATPUMP, TAG_TYPE_DEVICE_DATA, FL_(hpCompSpd), 15, 1), // hpcompspd REGISTER_MAPPING(dt::HEATPUMP, TAG_TYPE_DEVICE_DATA, FL_(hpCompSpd), 15, 1), // hpcompspd
REGISTER_MAPPING(dt::HEATPUMP, TAG_TYPE_DEVICE_DATA, FL_(hybridStrategy), 16, 1), // hybridstrategy REGISTER_MAPPING(dt::HEATPUMP, TAG_TYPE_DEVICE_DATA, FL_(hpActivity), 16, 1), // hpactivity
REGISTER_MAPPING(dt::HEATPUMP, TAG_TYPE_DEVICE_DATA, FL_(lowNoiseMode), 17, 1), // lownoisemode REGISTER_MAPPING(dt::HEATPUMP, TAG_TYPE_DEVICE_DATA, FL_(hpPower), 17, 1), // hppower
REGISTER_MAPPING(dt::HEATPUMP, TAG_TYPE_DEVICE_DATA, FL_(lowNoiseStart), 18, 1), // lownoisestart REGISTER_MAPPING(dt::HEATPUMP, TAG_TYPE_DEVICE_DATA, FL_(hpCurrPower), 18, 1), // hpcurrpower
REGISTER_MAPPING(dt::HEATPUMP, TAG_TYPE_DEVICE_DATA, FL_(lowNoiseStop), 19, 1), // lownoisestop REGISTER_MAPPING(dt::HEATPUMP, TAG_TYPE_DEVICE_DATA, FL_(hybridStrategy), 19, 1), // hybridstrategy
REGISTER_MAPPING(dt::HEATPUMP, TAG_TYPE_DEVICE_DATA, FL_(energyPriceGas), 20, 1), // energypricegas REGISTER_MAPPING(dt::HEATPUMP, TAG_TYPE_DEVICE_DATA, FL_(lowNoiseMode), 20, 1), // lownoisemode
REGISTER_MAPPING(dt::HEATPUMP, TAG_TYPE_DEVICE_DATA, FL_(energyPriceEl), 21, 1), // energypriceel REGISTER_MAPPING(dt::HEATPUMP, TAG_TYPE_DEVICE_DATA, FL_(lowNoiseStart), 21, 1), // lownoisestart
REGISTER_MAPPING(dt::HEATPUMP, TAG_TYPE_DEVICE_DATA, FL_(energyPricePV), 22, 1), // energyfeedpv REGISTER_MAPPING(dt::HEATPUMP, TAG_TYPE_DEVICE_DATA, FL_(lowNoiseStop), 22, 1), // lownoisestop
REGISTER_MAPPING(dt::HEATPUMP, TAG_TYPE_DEVICE_DATA, FL_(switchOverTemp), 23, 1), // switchovertemp REGISTER_MAPPING(dt::HEATPUMP, TAG_TYPE_DEVICE_DATA, FL_(energyPriceGas), 23, 1), // energypricegas
REGISTER_MAPPING(dt::HEATPUMP, TAG_TYPE_DEVICE_DATA, FL_(airPurgeMode), 24, 1), // airpurgemode REGISTER_MAPPING(dt::HEATPUMP, TAG_TYPE_DEVICE_DATA, FL_(energyPriceEl), 24, 1), // energypriceel
REGISTER_MAPPING(dt::HEATPUMP, TAG_TYPE_DEVICE_DATA, FL_(heatPumpOutput), 25, 1), // heatpumpoutput REGISTER_MAPPING(dt::HEATPUMP, TAG_TYPE_DEVICE_DATA, FL_(energyPricePV), 25, 1), // energyfeedpv
REGISTER_MAPPING(dt::HEATPUMP, TAG_TYPE_DEVICE_DATA, FL_(coolingCircuit), 26, 1), // coolingcircuit REGISTER_MAPPING(dt::HEATPUMP, TAG_TYPE_DEVICE_DATA, FL_(switchOverTemp), 26, 1), // switchovertemp
REGISTER_MAPPING(dt::HEATPUMP, TAG_TYPE_DEVICE_DATA, FL_(compStartMod), 27, 1), // compstartmod REGISTER_MAPPING(dt::HEATPUMP, TAG_TYPE_DEVICE_DATA, FL_(airPurgeMode), 27, 1), // airpurgemode
REGISTER_MAPPING(dt::HEATPUMP, TAG_TYPE_DEVICE_DATA, FL_(heatDrainPan), 28, 1), // heatdrainpan REGISTER_MAPPING(dt::HEATPUMP, TAG_TYPE_DEVICE_DATA, FL_(heatPumpOutput), 28, 1), // heatpumpoutput
REGISTER_MAPPING(dt::HEATPUMP, TAG_TYPE_DEVICE_DATA, FL_(heatCable), 29, 1), // heatcable REGISTER_MAPPING(dt::HEATPUMP, TAG_TYPE_DEVICE_DATA, FL_(coolingCircuit), 29, 1), // coolingcircuit
REGISTER_MAPPING(dt::HEATPUMP, TAG_TYPE_DEVICE_DATA, FL_(nrgTotal), 30, 2), // nrgtotal REGISTER_MAPPING(dt::HEATPUMP, TAG_TYPE_DEVICE_DATA, FL_(compStartMod), 30, 1), // compstartmod
REGISTER_MAPPING(dt::HEATPUMP, TAG_TYPE_DEVICE_DATA, FL_(nrgHeat), 32, 2), // nrgheat REGISTER_MAPPING(dt::HEATPUMP, TAG_TYPE_DEVICE_DATA, FL_(heatDrainPan), 31, 1), // heatdrainpan
REGISTER_MAPPING(dt::HEATPUMP, TAG_TYPE_DEVICE_DATA, FL_(meterTotal), 34, 2), // metertotal REGISTER_MAPPING(dt::HEATPUMP, TAG_TYPE_DEVICE_DATA, FL_(heatCable), 32, 1), // heatcable
REGISTER_MAPPING(dt::HEATPUMP, TAG_TYPE_DEVICE_DATA, FL_(meterComp), 36, 2), // metercomp REGISTER_MAPPING(dt::HEATPUMP, TAG_TYPE_DEVICE_DATA, FL_(nrgTotal), 33, 2), // nrgtotal
REGISTER_MAPPING(dt::HEATPUMP, TAG_TYPE_DEVICE_DATA, FL_(meterEHeat), 38, 2), // metereheat REGISTER_MAPPING(dt::HEATPUMP, TAG_TYPE_DEVICE_DATA, FL_(nrgHeat), 35, 2), // nrgheat
REGISTER_MAPPING(dt::HEATPUMP, TAG_TYPE_DEVICE_DATA, FL_(meterHeat), 40, 2), // meterheat REGISTER_MAPPING(dt::HEATPUMP, TAG_TYPE_DEVICE_DATA, FL_(meterTotal), 37, 2), // metertotal
REGISTER_MAPPING(dt::HEATPUMP, TAG_TYPE_DEVICE_DATA, FL_(heatingStarts), 42, 2), // heatingstarts REGISTER_MAPPING(dt::HEATPUMP, TAG_TYPE_DEVICE_DATA, FL_(meterComp), 39, 2), // metercomp
REGISTER_MAPPING(dt::HEATPUMP, TAG_TYPE_DEVICE_DATA, FL_(fuelHeat), 44, 2), // fuelheat REGISTER_MAPPING(dt::HEATPUMP, TAG_TYPE_DEVICE_DATA, FL_(meterEHeat), 41, 2), // metereheat
REGISTER_MAPPING(dt::HEATPUMP, TAG_TYPE_DEVICE_DATA, FL_(elHeat), 46, 2), // elheat REGISTER_MAPPING(dt::HEATPUMP, TAG_TYPE_DEVICE_DATA, FL_(meterHeat), 43, 2), // meterheat
REGISTER_MAPPING(dt::HEATPUMP, TAG_TYPE_DEVICE_DATA, FL_(elGenHeat), 48, 2), // elgenheat REGISTER_MAPPING(dt::HEATPUMP, TAG_TYPE_DEVICE_DATA, FL_(heatingStarts), 45, 2), // heatingstarts
REGISTER_MAPPING(dt::HEATPUMP, TAG_TYPE_DEVICE_DATA, FL_(fuelHeat), 47, 2), // fuelheat
REGISTER_MAPPING(dt::HEATPUMP, TAG_TYPE_DEVICE_DATA, FL_(elHeat), 49, 2), // elheat
REGISTER_MAPPING(dt::HEATPUMP, TAG_TYPE_DEVICE_DATA, FL_(elGenHeat), 51, 2), // elgenheat
REGISTER_MAPPING(dt::HEATPUMP, TAG_TYPE_DHW, FL_(hybridDHW), 0, 1), // hybriddhw REGISTER_MAPPING(dt::HEATPUMP, TAG_TYPE_DHW, FL_(hybridDHW), 0, 1), // hybriddhw
REGISTER_MAPPING(dt::HEATPUMP, TAG_TYPE_DHW, FL_(nrgWw), 1, 2), // nrg REGISTER_MAPPING(dt::HEATPUMP, TAG_TYPE_DHW, FL_(nrgWw), 1, 2), // nrg
REGISTER_MAPPING(dt::HEATPUMP, TAG_TYPE_DHW, FL_(meterWw), 3, 2), // meter REGISTER_MAPPING(dt::HEATPUMP, TAG_TYPE_DHW, FL_(meterWw), 3, 2), // meter