| heatingpumpmod | heating pump modulation | uint8 (>=0<=100) | % | false | DEVICE_DATA | 14 | 1 | 1 |
uint8
| hpcompspd | compressor speed | uint8 (>=0<=100) | % | false | DEVICE_DATA | 15 | 1 | 1 |
| hybridstrategy | hybrid control strategy | enum | | true | DEVICE_DATA | 16 | 1 | 1 |
| lownoisemode | low noise mode | enum | | true | DEVICE_DATA | 17 | 1 | 1 |
| hpactivity | compressor activity | enum | | false | DEVICE_DATA | 16 | 1 | 1 |
uint16
| hppower | compressor power output | uint16 (>=0<=31999) | W | false | DEVICE_DATA | 17 | 1 | 1 |
uint16
| hpcurrpower | compressor current power | uint16 (>=0<=31999) | W | false | DEVICE_DATA | 18 | 1 | 1 |
| hybridstrategy | hybrid control strategy | enum | | true | DEVICE_DATA | 19 | 1 | 1 |
| lownoisemode | low noise mode | enum | | true | DEVICE_DATA | 20 | 1 | 1 |
uint8
| lownoisestart | low noise starttime | uint8 (>=0<=23) | hours | true | DEVICE_DATA | 18 | 1 | 1 |
| lownoisestart | low noise starttime | uint8 (>=0<=23) | hours | true | DEVICE_DATA | 21 | 1 | 1 |
uint8
| lownoisestop | low noise stoptime | uint8 (>=0<=23) | hours | true | DEVICE_DATA | 19 | 1 | 1 |
| lownoisestop | low noise stoptime | uint8 (>=0<=23) | hours | true | DEVICE_DATA | 22 | 1 | 1 |
| dhw.hybriddhw | hybrid DHW | enum | | true | DHW | 0 | 1 | 1 |
uint8
| energypricegas | energy price gas | uint8 (>=0<=254) | ct/kWh | true | DEVICE_DATA | 20 | 1 | 1 |
| energypricegas | energy price gas | uint8 (>=0<=254) | ct/kWh | true | DEVICE_DATA | 23 | 1 | 1 |
uint8
| energypriceel | energy price electric | uint8 (>=0<=254) | ct/kWh | true | DEVICE_DATA | 21 | 1 | 1 |
| energypriceel | energy price electric | uint8 (>=0<=254) | ct/kWh | true | DEVICE_DATA | 24 | 1 | 1 |
uint8
| energyfeedpv | feed in PV | uint8 (>=0<=254) | ct/kWh | true | DEVICE_DATA | 22 | 1 | 1 |
| energyfeedpv | feed in PV | uint8 (>=0<=254) | ct/kWh | true | DEVICE_DATA | 25 | 1 | 1 |
int8
| switchovertemp | outside switchover temperature | int8 (>=-126<=126) | C | true | DEVICE_DATA | 23 | 1 | 1 |
| airpurgemode | air purge mode | boolean | | true | DEVICE_DATA | 24 | 1 | 1 |
| switchovertemp | outside switchover temperature | int8 (>=-126<=126) | C | true | DEVICE_DATA | 26 | 1 | 1 |
| airpurgemode | air purge mode | boolean | | true | DEVICE_DATA | 27 | 1 | 1 |
uint8
| heatpumpoutput | heatpump output | uint8 (>=0<=100) | % | true | DEVICE_DATA | 25 | 1 | 1 |
| coolingcircuit | cooling circuit | boolean | | true | DEVICE_DATA | 26 | 1 | 1 |
| heatpumpoutput | heatpump output | uint8 (>=0<=100) | % | true | DEVICE_DATA | 28 | 1 | 1 |
| coolingcircuit | cooling circuit | boolean | | true | DEVICE_DATA | 29 | 1 | 1 |
uint8
| compstartmod | compressor start modulation | uint8 (>=0<=100) | % | true | DEVICE_DATA | 27 | 1 | 1 |
| heatdrainpan | heat drain pan | boolean | | true | DEVICE_DATA | 28 | 1 | 1 |
| heatcable | heating cable | boolean | | true | DEVICE_DATA | 29 | 1 | 1 |
| compstartmod | compressor start modulation | uint8 (>=0<=100) | % | true | DEVICE_DATA | 30 | 1 | 1 |
| heatdrainpan | heat drain pan | boolean | | true | DEVICE_DATA | 31 | 1 | 1 |
| heatcable | heating cable | boolean | | true | DEVICE_DATA | 32 | 1 | 1 |
uint24
| nrgtotal | total energy | uint24 (>=0<=167772) | kWh | false | DEVICE_DATA | 30 | 2 | 1/100 |
| nrgtotal | total energy | uint24 (>=0<=167772) | kWh | false | DEVICE_DATA | 33 | 2 | 1/100 |
uint24
| dhw.nrg | energy | uint24 (>=0<=167772) | kWh | false | DHW | 1 | 2 | 1/100 |
uint24
| nrgheat | energy heating | uint24 (>=0<=167772) | kWh | false | DEVICE_DATA | 32 | 2 | 1/100 |
| nrgheat | energy heating | uint24 (>=0<=167772) | kWh | false | DEVICE_DATA | 35 | 2 | 1/100 |
uint24
| metertotal | meter total | uint24 (>=0<=167772) | kWh | false | DEVICE_DATA | 34 | 2 | 1/100 |
| metertotal | meter total | uint24 (>=0<=167772) | kWh | false | DEVICE_DATA | 37 | 2 | 1/100 |
uint24
| metercomp | meter compressor | uint24 (>=0<=167772) | kWh | false | DEVICE_DATA | 36 | 2 | 1/100 |
| metercomp | meter compressor | uint24 (>=0<=167772) | kWh | false | DEVICE_DATA | 39 | 2 | 1/100 |
uint24
| metereheat | meter e-heater | uint24 (>=0<=167772) | kWh | false | DEVICE_DATA | 38 | 2 | 1/100 |
| metereheat | meter e-heater | uint24 (>=0<=167772) | kWh | false | DEVICE_DATA | 41 | 2 | 1/100 |
uint24
| meterheat | meter heating | uint24 (>=0<=167772) | kWh | false | DEVICE_DATA | 40 | 2 | 1/100 |
| meterheat | meter heating | uint24 (>=0<=167772) | kWh | false | DEVICE_DATA | 43 | 2 | 1/100 |
uint24
| dhw.meter | meter | uint24 (>=0<=167772) | kWh | false | DHW | 3 | 2 | 1/100 |
uint24
| heatingstarts | heating control starts | uint24 (>=0<=16777214) | | false | DEVICE_DATA | 42 | 2 | 1 |
| heatingstarts | heating control starts | uint24 (>=0<=16777214) | | false | DEVICE_DATA | 45 | 2 | 1 |
uint24
| dhw.startshp | starts hp | uint24 (>=0<=16777214) | | false | DHW | 5 | 2 | 1 |
uint32
| fuelheat | fuel consumption heating | uint32 (>=0<=1677721) | kWh | false | DEVICE_DATA | 44 | 2 | 1/10 |
| fuelheat | fuel consumption heating | uint32 (>=0<=1677721) | kWh | false | DEVICE_DATA | 47 | 2 | 1/10 |
uint32
| dhw.fueldhw | fuel consumption | uint32 (>=0<=1677721) | kWh | false | DHW | 7 | 2 | 1/10 |
uint32
| elheat | el. consumption heating | uint32 (>=0<=1677721) | kWh | false | DEVICE_DATA | 46 | 2 | 1/10 |
| elheat | el. consumption heating | uint32 (>=0<=1677721) | kWh | false | DEVICE_DATA | 49 | 2 | 1/10 |
uint32
| dhw.eldhw | el. consumption | uint32 (>=0<=1677721) | kWh | false | DHW | 9 | 2 | 1/10 |
uint32
| elgenheat | el. generation heating | uint32 (>=0<=1677721) | kWh | false | DEVICE_DATA | 48 | 2 | 1/10 |
| elgenheat | el. generation heating | uint32 (>=0<=1677721) | kWh | false | DEVICE_DATA | 51 | 2 | 1/10 |
uint32
| dhw.elgendhw | el generation | uint32 (>=0<=1677721) | kWh | false | DHW | 11 | 2 | 1/10 |
@@ -9375,59 +9380,64 @@ uint8
| heatingpumpmod | heating pump modulation | uint8 (>=0<=100) | % | false | DEVICE_DATA | 14 | 1 | 1 |
uint8
| hpcompspd | compressor speed | uint8 (>=0<=100) | % | false | DEVICE_DATA | 15 | 1 | 1 |
| hybridstrategy | hybrid control strategy | enum | | true | DEVICE_DATA | 16 | 1 | 1 |
| lownoisemode | low noise mode | enum | | true | DEVICE_DATA | 17 | 1 | 1 |
| hpactivity | compressor activity | enum | | false | DEVICE_DATA | 16 | 1 | 1 |
uint16
| hppower | compressor power output | uint16 (>=0<=31999) | W | false | DEVICE_DATA | 17 | 1 | 1 |
uint16
| hpcurrpower | compressor current power | uint16 (>=0<=31999) | W | false | DEVICE_DATA | 18 | 1 | 1 |
| hybridstrategy | hybrid control strategy | enum | | true | DEVICE_DATA | 19 | 1 | 1 |
| lownoisemode | low noise mode | enum | | true | DEVICE_DATA | 20 | 1 | 1 |
uint8
| lownoisestart | low noise starttime | uint8 (>=0<=23) | hours | true | DEVICE_DATA | 18 | 1 | 1 |
| lownoisestart | low noise starttime | uint8 (>=0<=23) | hours | true | DEVICE_DATA | 21 | 1 | 1 |
uint8
| lownoisestop | low noise stoptime | uint8 (>=0<=23) | hours | true | DEVICE_DATA | 19 | 1 | 1 |
| lownoisestop | low noise stoptime | uint8 (>=0<=23) | hours | true | DEVICE_DATA | 22 | 1 | 1 |
| dhw.hybriddhw | hybrid DHW | enum | | true | DHW | 0 | 1 | 1 |
uint8
| energypricegas | energy price gas | uint8 (>=0<=254) | ct/kWh | true | DEVICE_DATA | 20 | 1 | 1 |
| energypricegas | energy price gas | uint8 (>=0<=254) | ct/kWh | true | DEVICE_DATA | 23 | 1 | 1 |
uint8
| energypriceel | energy price electric | uint8 (>=0<=254) | ct/kWh | true | DEVICE_DATA | 21 | 1 | 1 |
| energypriceel | energy price electric | uint8 (>=0<=254) | ct/kWh | true | DEVICE_DATA | 24 | 1 | 1 |
uint8
| energyfeedpv | feed in PV | uint8 (>=0<=254) | ct/kWh | true | DEVICE_DATA | 22 | 1 | 1 |
| energyfeedpv | feed in PV | uint8 (>=0<=254) | ct/kWh | true | DEVICE_DATA | 25 | 1 | 1 |
int8
| switchovertemp | outside switchover temperature | int8 (>=-126<=126) | C | true | DEVICE_DATA | 23 | 1 | 1 |
| airpurgemode | air purge mode | boolean | | true | DEVICE_DATA | 24 | 1 | 1 |
| switchovertemp | outside switchover temperature | int8 (>=-126<=126) | C | true | DEVICE_DATA | 26 | 1 | 1 |
| airpurgemode | air purge mode | boolean | | true | DEVICE_DATA | 27 | 1 | 1 |
uint8
| heatpumpoutput | heatpump output | uint8 (>=0<=100) | % | true | DEVICE_DATA | 25 | 1 | 1 |
| coolingcircuit | cooling circuit | boolean | | true | DEVICE_DATA | 26 | 1 | 1 |
| heatpumpoutput | heatpump output | uint8 (>=0<=100) | % | true | DEVICE_DATA | 28 | 1 | 1 |
| coolingcircuit | cooling circuit | boolean | | true | DEVICE_DATA | 29 | 1 | 1 |
uint8
| compstartmod | compressor start modulation | uint8 (>=0<=100) | % | true | DEVICE_DATA | 27 | 1 | 1 |
| heatdrainpan | heat drain pan | boolean | | true | DEVICE_DATA | 28 | 1 | 1 |
| heatcable | heating cable | boolean | | true | DEVICE_DATA | 29 | 1 | 1 |
| compstartmod | compressor start modulation | uint8 (>=0<=100) | % | true | DEVICE_DATA | 30 | 1 | 1 |
| heatdrainpan | heat drain pan | boolean | | true | DEVICE_DATA | 31 | 1 | 1 |
| heatcable | heating cable | boolean | | true | DEVICE_DATA | 32 | 1 | 1 |
uint24
| nrgtotal | total energy | uint24 (>=0<=167772) | kWh | false | DEVICE_DATA | 30 | 2 | 1/100 |
| nrgtotal | total energy | uint24 (>=0<=167772) | kWh | false | DEVICE_DATA | 33 | 2 | 1/100 |
uint24
| dhw.nrg | energy | uint24 (>=0<=167772) | kWh | false | DHW | 1 | 2 | 1/100 |
uint24
| nrgheat | energy heating | uint24 (>=0<=167772) | kWh | false | DEVICE_DATA | 32 | 2 | 1/100 |
| nrgheat | energy heating | uint24 (>=0<=167772) | kWh | false | DEVICE_DATA | 35 | 2 | 1/100 |
uint24
| metertotal | meter total | uint24 (>=0<=167772) | kWh | false | DEVICE_DATA | 34 | 2 | 1/100 |
| metertotal | meter total | uint24 (>=0<=167772) | kWh | false | DEVICE_DATA | 37 | 2 | 1/100 |
uint24
| metercomp | meter compressor | uint24 (>=0<=167772) | kWh | false | DEVICE_DATA | 36 | 2 | 1/100 |
| metercomp | meter compressor | uint24 (>=0<=167772) | kWh | false | DEVICE_DATA | 39 | 2 | 1/100 |
uint24
| metereheat | meter e-heater | uint24 (>=0<=167772) | kWh | false | DEVICE_DATA | 38 | 2 | 1/100 |
| metereheat | meter e-heater | uint24 (>=0<=167772) | kWh | false | DEVICE_DATA | 41 | 2 | 1/100 |
uint24
| meterheat | meter heating | uint24 (>=0<=167772) | kWh | false | DEVICE_DATA | 40 | 2 | 1/100 |
| meterheat | meter heating | uint24 (>=0<=167772) | kWh | false | DEVICE_DATA | 43 | 2 | 1/100 |
uint24
| dhw.meter | meter | uint24 (>=0<=167772) | kWh | false | DHW | 3 | 2 | 1/100 |
uint24
| heatingstarts | heating control starts | uint24 (>=0<=16777214) | | false | DEVICE_DATA | 42 | 2 | 1 |
| heatingstarts | heating control starts | uint24 (>=0<=16777214) | | false | DEVICE_DATA | 45 | 2 | 1 |
uint24
| dhw.startshp | starts hp | uint24 (>=0<=16777214) | | false | DHW | 5 | 2 | 1 |
uint32
| fuelheat | fuel consumption heating | uint32 (>=0<=1677721) | kWh | false | DEVICE_DATA | 44 | 2 | 1/10 |
| fuelheat | fuel consumption heating | uint32 (>=0<=1677721) | kWh | false | DEVICE_DATA | 47 | 2 | 1/10 |
uint32
| dhw.fueldhw | fuel consumption | uint32 (>=0<=1677721) | kWh | false | DHW | 7 | 2 | 1/10 |
uint32
| elheat | el. consumption heating | uint32 (>=0<=1677721) | kWh | false | DEVICE_DATA | 46 | 2 | 1/10 |
| elheat | el. consumption heating | uint32 (>=0<=1677721) | kWh | false | DEVICE_DATA | 49 | 2 | 1/10 |
uint32
| dhw.eldhw | el. consumption | uint32 (>=0<=1677721) | kWh | false | DHW | 9 | 2 | 1/10 |
uint32
| elgenheat | el. generation heating | uint32 (>=0<=1677721) | kWh | false | DEVICE_DATA | 48 | 2 | 1/10 |
| elgenheat | el. generation heating | uint32 (>=0<=1677721) | kWh | false | DEVICE_DATA | 51 | 2 | 1/10 |
uint32
| dhw.elgendhw | el generation | uint32 (>=0<=1677721) | kWh | false | DHW | 11 | 2 | 1/10 |
@@ -9467,59 +9477,64 @@ uint8
| heatingpumpmod | heating pump modulation | uint8 (>=0<=100) | % | false | DEVICE_DATA | 14 | 1 | 1 |
uint8
| hpcompspd | compressor speed | uint8 (>=0<=100) | % | false | DEVICE_DATA | 15 | 1 | 1 |
| hybridstrategy | hybrid control strategy | enum | | true | DEVICE_DATA | 16 | 1 | 1 |
| lownoisemode | low noise mode | enum | | true | DEVICE_DATA | 17 | 1 | 1 |
| hpactivity | compressor activity | enum | | false | DEVICE_DATA | 16 | 1 | 1 |
uint16
| hppower | compressor power output | uint16 (>=0<=31999) | W | false | DEVICE_DATA | 17 | 1 | 1 |
uint16
| hpcurrpower | compressor current power | uint16 (>=0<=31999) | W | false | DEVICE_DATA | 18 | 1 | 1 |
| hybridstrategy | hybrid control strategy | enum | | true | DEVICE_DATA | 19 | 1 | 1 |
| lownoisemode | low noise mode | enum | | true | DEVICE_DATA | 20 | 1 | 1 |
uint8
| lownoisestart | low noise starttime | uint8 (>=0<=23) | hours | true | DEVICE_DATA | 18 | 1 | 1 |
| lownoisestart | low noise starttime | uint8 (>=0<=23) | hours | true | DEVICE_DATA | 21 | 1 | 1 |
uint8
| lownoisestop | low noise stoptime | uint8 (>=0<=23) | hours | true | DEVICE_DATA | 19 | 1 | 1 |
| lownoisestop | low noise stoptime | uint8 (>=0<=23) | hours | true | DEVICE_DATA | 22 | 1 | 1 |
| dhw.hybriddhw | hybrid DHW | enum | | true | DHW | 0 | 1 | 1 |
uint8
| energypricegas | energy price gas | uint8 (>=0<=254) | ct/kWh | true | DEVICE_DATA | 20 | 1 | 1 |
| energypricegas | energy price gas | uint8 (>=0<=254) | ct/kWh | true | DEVICE_DATA | 23 | 1 | 1 |
uint8
| energypriceel | energy price electric | uint8 (>=0<=254) | ct/kWh | true | DEVICE_DATA | 21 | 1 | 1 |
| energypriceel | energy price electric | uint8 (>=0<=254) | ct/kWh | true | DEVICE_DATA | 24 | 1 | 1 |
uint8
| energyfeedpv | feed in PV | uint8 (>=0<=254) | ct/kWh | true | DEVICE_DATA | 22 | 1 | 1 |
| energyfeedpv | feed in PV | uint8 (>=0<=254) | ct/kWh | true | DEVICE_DATA | 25 | 1 | 1 |
int8
| switchovertemp | outside switchover temperature | int8 (>=-126<=126) | C | true | DEVICE_DATA | 23 | 1 | 1 |
| airpurgemode | air purge mode | boolean | | true | DEVICE_DATA | 24 | 1 | 1 |
| switchovertemp | outside switchover temperature | int8 (>=-126<=126) | C | true | DEVICE_DATA | 26 | 1 | 1 |
| airpurgemode | air purge mode | boolean | | true | DEVICE_DATA | 27 | 1 | 1 |
uint8
| heatpumpoutput | heatpump output | uint8 (>=0<=100) | % | true | DEVICE_DATA | 25 | 1 | 1 |
| coolingcircuit | cooling circuit | boolean | | true | DEVICE_DATA | 26 | 1 | 1 |
| heatpumpoutput | heatpump output | uint8 (>=0<=100) | % | true | DEVICE_DATA | 28 | 1 | 1 |
| coolingcircuit | cooling circuit | boolean | | true | DEVICE_DATA | 29 | 1 | 1 |
uint8
| compstartmod | compressor start modulation | uint8 (>=0<=100) | % | true | DEVICE_DATA | 27 | 1 | 1 |
| heatdrainpan | heat drain pan | boolean | | true | DEVICE_DATA | 28 | 1 | 1 |
| heatcable | heating cable | boolean | | true | DEVICE_DATA | 29 | 1 | 1 |
| compstartmod | compressor start modulation | uint8 (>=0<=100) | % | true | DEVICE_DATA | 30 | 1 | 1 |
| heatdrainpan | heat drain pan | boolean | | true | DEVICE_DATA | 31 | 1 | 1 |
| heatcable | heating cable | boolean | | true | DEVICE_DATA | 32 | 1 | 1 |
uint24
| nrgtotal | total energy | uint24 (>=0<=167772) | kWh | false | DEVICE_DATA | 30 | 2 | 1/100 |
| nrgtotal | total energy | uint24 (>=0<=167772) | kWh | false | DEVICE_DATA | 33 | 2 | 1/100 |
uint24
| dhw.nrg | energy | uint24 (>=0<=167772) | kWh | false | DHW | 1 | 2 | 1/100 |
uint24
| nrgheat | energy heating | uint24 (>=0<=167772) | kWh | false | DEVICE_DATA | 32 | 2 | 1/100 |
| nrgheat | energy heating | uint24 (>=0<=167772) | kWh | false | DEVICE_DATA | 35 | 2 | 1/100 |
uint24
| metertotal | meter total | uint24 (>=0<=167772) | kWh | false | DEVICE_DATA | 34 | 2 | 1/100 |
| metertotal | meter total | uint24 (>=0<=167772) | kWh | false | DEVICE_DATA | 37 | 2 | 1/100 |
uint24
| metercomp | meter compressor | uint24 (>=0<=167772) | kWh | false | DEVICE_DATA | 36 | 2 | 1/100 |
| metercomp | meter compressor | uint24 (>=0<=167772) | kWh | false | DEVICE_DATA | 39 | 2 | 1/100 |
uint24
| metereheat | meter e-heater | uint24 (>=0<=167772) | kWh | false | DEVICE_DATA | 38 | 2 | 1/100 |
| metereheat | meter e-heater | uint24 (>=0<=167772) | kWh | false | DEVICE_DATA | 41 | 2 | 1/100 |
uint24
| meterheat | meter heating | uint24 (>=0<=167772) | kWh | false | DEVICE_DATA | 40 | 2 | 1/100 |
| meterheat | meter heating | uint24 (>=0<=167772) | kWh | false | DEVICE_DATA | 43 | 2 | 1/100 |
uint24
| dhw.meter | meter | uint24 (>=0<=167772) | kWh | false | DHW | 3 | 2 | 1/100 |
uint24
| heatingstarts | heating control starts | uint24 (>=0<=16777214) | | false | DEVICE_DATA | 42 | 2 | 1 |
| heatingstarts | heating control starts | uint24 (>=0<=16777214) | | false | DEVICE_DATA | 45 | 2 | 1 |
uint24
| dhw.startshp | starts hp | uint24 (>=0<=16777214) | | false | DHW | 5 | 2 | 1 |
uint32
| fuelheat | fuel consumption heating | uint32 (>=0<=1677721) | kWh | false | DEVICE_DATA | 44 | 2 | 1/10 |
| fuelheat | fuel consumption heating | uint32 (>=0<=1677721) | kWh | false | DEVICE_DATA | 47 | 2 | 1/10 |
uint32
| dhw.fueldhw | fuel consumption | uint32 (>=0<=1677721) | kWh | false | DHW | 7 | 2 | 1/10 |
uint32
| elheat | el. consumption heating | uint32 (>=0<=1677721) | kWh | false | DEVICE_DATA | 46 | 2 | 1/10 |
| elheat | el. consumption heating | uint32 (>=0<=1677721) | kWh | false | DEVICE_DATA | 49 | 2 | 1/10 |
uint32
| dhw.eldhw | el. consumption | uint32 (>=0<=1677721) | kWh | false | DHW | 9 | 2 | 1/10 |
uint32
| elgenheat | el. generation heating | uint32 (>=0<=1677721) | kWh | false | DEVICE_DATA | 48 | 2 | 1/10 |
| elgenheat | el. generation heating | uint32 (>=0<=1677721) | kWh | false | DEVICE_DATA | 51 | 2 | 1/10 |
uint32
| dhw.elgendhw | el generation | uint32 (>=0<=1677721) | kWh | false | DHW | 11 | 2 | 1/10 |

View File

@@ -5609,36 +5609,39 @@ device name,device type,product id,shortname,fullname,type [options...] \| (min/
"HP Module",heatpump,252,hpph1,high pressure side temperature (PH1),int16 (>=-3199<=3199),C,false,sensor.heatpump_high_pressure_side_temperature_(PH1),sensor.heatpump_hpph1,9,0,1/10,13,1
"HP Module",heatpump,252,heatingpumpmod,heating pump modulation,uint8 (>=0<=100),%,false,sensor.heatpump_heating_pump_modulation,sensor.heatpump_heatingpumpmod,9,0,1,14,1
"HP Module",heatpump,252,hpcompspd,compressor speed,uint8 (>=0<=100),%,false,sensor.heatpump_compressor_speed,sensor.heatpump_hpcompspd,9,0,1,15,1
"HP Module",heatpump,252,hybridstrategy,hybrid control strategy,enum [cost optimized\|co2 optimized\|outside temperature alt.\|outside temperature parallel\|heatpump preferred\|boiler only], ,true,select.heatpump_hybrid_control_strategy,select.heatpump_hybridstrategy,9,0,1,16,1
"HP Module",heatpump,252,lownoisemode,low noise mode,enum [off\|reduced output\|switch off hp\|perm. reduced], ,true,select.heatpump_low_noise_mode,select.heatpump_lownoisemode,9,0,1,17,1
"HP Module",heatpump,252,lownoisestart,low noise starttime,uint8 (>=0<=23),hours,true,number.heatpump_low_noise_starttime,number.heatpump_lownoisestart,9,0,1,18,1
"HP Module",heatpump,252,lownoisestop,low noise stoptime,uint8 (>=0<=23),hours,true,number.heatpump_low_noise_stoptime,number.heatpump_lownoisestop,9,0,1,19,1
"HP Module",heatpump,252,hpactivity,compressor activity,enum [off\|heating\|hot water\|defrost\|compressor alarm], ,false,sensor.heatpump_compressor_activity,sensor.heatpump_hpactivity,9,0,1,16,1
"HP Module",heatpump,252,hppower,compressor power output,uint16 (>=0<=31999),W,false,sensor.heatpump_compressor_power_output,sensor.heatpump_hppower,9,0,1,17,1
"HP Module",heatpump,252,hpcurrpower,compressor current power,uint16 (>=0<=31999),W,false,sensor.heatpump_compressor_current_power,sensor.heatpump_hpcurrpower,9,0,1,18,1
"HP Module",heatpump,252,hybridstrategy,hybrid control strategy,enum [cost optimized\|co2 optimized\|outside temperature alt.\|outside temperature parallel\|heatpump preferred\|boiler only], ,true,select.heatpump_hybrid_control_strategy,select.heatpump_hybridstrategy,9,0,1,19,1
"HP Module",heatpump,252,lownoisemode,low noise mode,enum [off\|reduced output\|switch off hp\|perm. reduced], ,true,select.heatpump_low_noise_mode,select.heatpump_lownoisemode,9,0,1,20,1
"HP Module",heatpump,252,lownoisestart,low noise starttime,uint8 (>=0<=23),hours,true,number.heatpump_low_noise_starttime,number.heatpump_lownoisestart,9,0,1,21,1
"HP Module",heatpump,252,lownoisestop,low noise stoptime,uint8 (>=0<=23),hours,true,number.heatpump_low_noise_stoptime,number.heatpump_lownoisestop,9,0,1,22,1
"HP Module",heatpump,252,dhw.hybriddhw,hybrid DHW,enum [eco\|high comfort], ,true,select.heatpump_dhw_hybrid_DHW,select.heatpump_dhw_hybriddhw,9,9,1,0,1
"HP Module",heatpump,252,energypricegas,energy price gas,uint8 (>=0<=254),ct/kWh,true,number.heatpump_energy_price_gas,number.heatpump_energypricegas,9,0,1,20,1
"HP Module",heatpump,252,energypriceel,energy price electric,uint8 (>=0<=254),ct/kWh,true,number.heatpump_energy_price_electric,number.heatpump_energypriceel,9,0,1,21,1
"HP Module",heatpump,252,energyfeedpv,feed in PV,uint8 (>=0<=254),ct/kWh,true,number.heatpump_feed_in_PV,number.heatpump_energyfeedpv,9,0,1,22,1
"HP Module",heatpump,252,switchovertemp,outside switchover temperature,int8 (>=-126<=126),C,true,number.heatpump_outside_switchover_temperature,number.heatpump_switchovertemp,9,0,1,23,1
"HP Module",heatpump,252,airpurgemode,air purge mode,boolean, ,true,switch.heatpump_air_purge_mode,switch.heatpump_airpurgemode,9,0,1,24,1
"HP Module",heatpump,252,heatpumpoutput,heatpump output,uint8 (>=0<=100),%,true,number.heatpump_heatpump_output,number.heatpump_heatpumpoutput,9,0,1,25,1
"HP Module",heatpump,252,coolingcircuit,cooling circuit,boolean, ,true,switch.heatpump_cooling_circuit,switch.heatpump_coolingcircuit,9,0,1,26,1
"HP Module",heatpump,252,compstartmod,compressor start modulation,uint8 (>=0<=100),%,true,number.heatpump_compressor_start_modulation,number.heatpump_compstartmod,9,0,1,27,1
"HP Module",heatpump,252,heatdrainpan,heat drain pan,boolean, ,true,switch.heatpump_heat_drain_pan,switch.heatpump_heatdrainpan,9,0,1,28,1
"HP Module",heatpump,252,heatcable,heating cable,boolean, ,true,switch.heatpump_heating_cable,switch.heatpump_heatcable,9,0,1,29,1
"HP Module",heatpump,252,nrgtotal,total energy,uint24 (>=0<=167772),kWh,false,sensor.heatpump_total_energy,sensor.heatpump_nrgtotal,9,0,1/100,30,2
"HP Module",heatpump,252,energypricegas,energy price gas,uint8 (>=0<=254),ct/kWh,true,number.heatpump_energy_price_gas,number.heatpump_energypricegas,9,0,1,23,1
"HP Module",heatpump,252,energypriceel,energy price electric,uint8 (>=0<=254),ct/kWh,true,number.heatpump_energy_price_electric,number.heatpump_energypriceel,9,0,1,24,1
"HP Module",heatpump,252,energyfeedpv,feed in PV,uint8 (>=0<=254),ct/kWh,true,number.heatpump_feed_in_PV,number.heatpump_energyfeedpv,9,0,1,25,1
"HP Module",heatpump,252,switchovertemp,outside switchover temperature,int8 (>=-126<=126),C,true,number.heatpump_outside_switchover_temperature,number.heatpump_switchovertemp,9,0,1,26,1
"HP Module",heatpump,252,airpurgemode,air purge mode,boolean, ,true,switch.heatpump_air_purge_mode,switch.heatpump_airpurgemode,9,0,1,27,1
"HP Module",heatpump,252,heatpumpoutput,heatpump output,uint8 (>=0<=100),%,true,number.heatpump_heatpump_output,number.heatpump_heatpumpoutput,9,0,1,28,1
"HP Module",heatpump,252,coolingcircuit,cooling circuit,boolean, ,true,switch.heatpump_cooling_circuit,switch.heatpump_coolingcircuit,9,0,1,29,1
"HP Module",heatpump,252,compstartmod,compressor start modulation,uint8 (>=0<=100),%,true,number.heatpump_compressor_start_modulation,number.heatpump_compstartmod,9,0,1,30,1
"HP Module",heatpump,252,heatdrainpan,heat drain pan,boolean, ,true,switch.heatpump_heat_drain_pan,switch.heatpump_heatdrainpan,9,0,1,31,1
"HP Module",heatpump,252,heatcable,heating cable,boolean, ,true,switch.heatpump_heating_cable,switch.heatpump_heatcable,9,0,1,32,1
"HP Module",heatpump,252,nrgtotal,total energy,uint24 (>=0<=167772),kWh,false,sensor.heatpump_total_energy,sensor.heatpump_nrgtotal,9,0,1/100,33,2
"HP Module",heatpump,252,dhw.nrg,energy,uint24 (>=0<=167772),kWh,false,sensor.heatpump_dhw_energy,sensor.heatpump_dhw_nrg,9,9,1/100,1,2
"HP Module",heatpump,252,nrgheat,energy heating,uint24 (>=0<=167772),kWh,false,sensor.heatpump_energy_heating,sensor.heatpump_nrgheat,9,0,1/100,32,2
"HP Module",heatpump,252,metertotal,meter total,uint24 (>=0<=167772),kWh,false,sensor.heatpump_meter_total,sensor.heatpump_metertotal,9,0,1/100,34,2
"HP Module",heatpump,252,metercomp,meter compressor,uint24 (>=0<=167772),kWh,false,sensor.heatpump_meter_compressor,sensor.heatpump_metercomp,9,0,1/100,36,2
"HP Module",heatpump,252,metereheat,meter e-heater,uint24 (>=0<=167772),kWh,false,sensor.heatpump_meter_e-heater,sensor.heatpump_metereheat,9,0,1/100,38,2
"HP Module",heatpump,252,meterheat,meter heating,uint24 (>=0<=167772),kWh,false,sensor.heatpump_meter_heating,sensor.heatpump_meterheat,9,0,1/100,40,2
"HP Module",heatpump,252,nrgheat,energy heating,uint24 (>=0<=167772),kWh,false,sensor.heatpump_energy_heating,sensor.heatpump_nrgheat,9,0,1/100,35,2
"HP Module",heatpump,252,metertotal,meter total,uint24 (>=0<=167772),kWh,false,sensor.heatpump_meter_total,sensor.heatpump_metertotal,9,0,1/100,37,2
"HP Module",heatpump,252,metercomp,meter compressor,uint24 (>=0<=167772),kWh,false,sensor.heatpump_meter_compressor,sensor.heatpump_metercomp,9,0,1/100,39,2
"HP Module",heatpump,252,metereheat,meter e-heater,uint24 (>=0<=167772),kWh,false,sensor.heatpump_meter_e-heater,sensor.heatpump_metereheat,9,0,1/100,41,2
"HP Module",heatpump,252,meterheat,meter heating,uint24 (>=0<=167772),kWh,false,sensor.heatpump_meter_heating,sensor.heatpump_meterheat,9,0,1/100,43,2
"HP Module",heatpump,252,dhw.meter,meter,uint24 (>=0<=167772),kWh,false,sensor.heatpump_dhw_meter,sensor.heatpump_dhw_meter,9,9,1/100,3,2
"HP Module",heatpump,252,heatingstarts,heating control starts,uint24 (>=0<=16777214), ,false,sensor.heatpump_heating_control_starts,sensor.heatpump_heatingstarts,9,0,1,42,2
"HP Module",heatpump,252,heatingstarts,heating control starts,uint24 (>=0<=16777214), ,false,sensor.heatpump_heating_control_starts,sensor.heatpump_heatingstarts,9,0,1,45,2
"HP Module",heatpump,252,dhw.startshp,starts hp,uint24 (>=0<=16777214), ,false,sensor.heatpump_dhw_starts_hp,sensor.heatpump_dhw_startshp,9,9,1,5,2
"HP Module",heatpump,252,fuelheat,fuel consumption heating,uint32 (>=0<=1677721),kWh,false,sensor.heatpump_fuel_consumption_heating,sensor.heatpump_fuelheat,9,0,1/10,44,2
"HP Module",heatpump,252,fuelheat,fuel consumption heating,uint32 (>=0<=1677721),kWh,false,sensor.heatpump_fuel_consumption_heating,sensor.heatpump_fuelheat,9,0,1/10,47,2
"HP Module",heatpump,252,dhw.fueldhw,fuel consumption,uint32 (>=0<=1677721),kWh,false,sensor.heatpump_dhw_fuel_consumption,sensor.heatpump_dhw_fueldhw,9,9,1/10,7,2
"HP Module",heatpump,252,elheat,el. consumption heating,uint32 (>=0<=1677721),kWh,false,sensor.heatpump_el._consumption_heating,sensor.heatpump_elheat,9,0,1/10,46,2
"HP Module",heatpump,252,elheat,el. consumption heating,uint32 (>=0<=1677721),kWh,false,sensor.heatpump_el._consumption_heating,sensor.heatpump_elheat,9,0,1/10,49,2
"HP Module",heatpump,252,dhw.eldhw,el. consumption,uint32 (>=0<=1677721),kWh,false,sensor.heatpump_dhw_el._consumption,sensor.heatpump_dhw_eldhw,9,9,1/10,9,2
"HP Module",heatpump,252,elgenheat,el. generation heating,uint32 (>=0<=1677721),kWh,false,sensor.heatpump_el._generation_heating,sensor.heatpump_elgenheat,9,0,1/10,48,2
"HP Module",heatpump,252,elgenheat,el. generation heating,uint32 (>=0<=1677721),kWh,false,sensor.heatpump_el._generation_heating,sensor.heatpump_elgenheat,9,0,1/10,51,2
"HP Module",heatpump,252,dhw.elgendhw,el generation,uint32 (>=0<=1677721),kWh,false,sensor.heatpump_dhw_el_generation,sensor.heatpump_dhw_elgendhw,9,9,1/10,11,2
"Hybrid Manager HM200",heatpump,248,airhumidity,relative air humidity,uint8 (>=0<=100),%,false,sensor.heatpump_relative_air_humidity,sensor.heatpump_airhumidity,9,0,1,0,1
"Hybrid Manager HM200",heatpump,248,dewtemperature,dew point temperature,uint8 (>=0<=254),C,false,sensor.heatpump_dew_point_temperature,sensor.heatpump_dewtemperature,9,0,1,1,1
@@ -5656,36 +5659,39 @@ device name,device type,product id,shortname,fullname,type [options...] \| (min/
"Hybrid Manager HM200",heatpump,248,hpph1,high pressure side temperature (PH1),int16 (>=-3199<=3199),C,false,sensor.heatpump_high_pressure_side_temperature_(PH1),sensor.heatpump_hpph1,9,0,1/10,13,1
"Hybrid Manager HM200",heatpump,248,heatingpumpmod,heating pump modulation,uint8 (>=0<=100),%,false,sensor.heatpump_heating_pump_modulation,sensor.heatpump_heatingpumpmod,9,0,1,14,1
"Hybrid Manager HM200",heatpump,248,hpcompspd,compressor speed,uint8 (>=0<=100),%,false,sensor.heatpump_compressor_speed,sensor.heatpump_hpcompspd,9,0,1,15,1
"Hybrid Manager HM200",heatpump,248,hybridstrategy,hybrid control strategy,enum [cost optimized\|co2 optimized\|outside temperature alt.\|outside temperature parallel\|heatpump preferred\|boiler only], ,true,select.heatpump_hybrid_control_strategy,select.heatpump_hybridstrategy,9,0,1,16,1
"Hybrid Manager HM200",heatpump,248,lownoisemode,low noise mode,enum [off\|reduced output\|switch off hp\|perm. reduced], ,true,select.heatpump_low_noise_mode,select.heatpump_lownoisemode,9,0,1,17,1
"Hybrid Manager HM200",heatpump,248,lownoisestart,low noise starttime,uint8 (>=0<=23),hours,true,number.heatpump_low_noise_starttime,number.heatpump_lownoisestart,9,0,1,18,1
"Hybrid Manager HM200",heatpump,248,lownoisestop,low noise stoptime,uint8 (>=0<=23),hours,true,number.heatpump_low_noise_stoptime,number.heatpump_lownoisestop,9,0,1,19,1
"Hybrid Manager HM200",heatpump,248,hpactivity,compressor activity,enum [off\|heating\|hot water\|defrost\|compressor alarm], ,false,sensor.heatpump_compressor_activity,sensor.heatpump_hpactivity,9,0,1,16,1
"Hybrid Manager HM200",heatpump,248,hppower,compressor power output,uint16 (>=0<=31999),W,false,sensor.heatpump_compressor_power_output,sensor.heatpump_hppower,9,0,1,17,1
"Hybrid Manager HM200",heatpump,248,hpcurrpower,compressor current power,uint16 (>=0<=31999),W,false,sensor.heatpump_compressor_current_power,sensor.heatpump_hpcurrpower,9,0,1,18,1
"Hybrid Manager HM200",heatpump,248,hybridstrategy,hybrid control strategy,enum [cost optimized\|co2 optimized\|outside temperature alt.\|outside temperature parallel\|heatpump preferred\|boiler only], ,true,select.heatpump_hybrid_control_strategy,select.heatpump_hybridstrategy,9,0,1,19,1
"Hybrid Manager HM200",heatpump,248,lownoisemode,low noise mode,enum [off\|reduced output\|switch off hp\|perm. reduced], ,true,select.heatpump_low_noise_mode,select.heatpump_lownoisemode,9,0,1,20,1
"Hybrid Manager HM200",heatpump,248,lownoisestart,low noise starttime,uint8 (>=0<=23),hours,true,number.heatpump_low_noise_starttime,number.heatpump_lownoisestart,9,0,1,21,1
"Hybrid Manager HM200",heatpump,248,lownoisestop,low noise stoptime,uint8 (>=0<=23),hours,true,number.heatpump_low_noise_stoptime,number.heatpump_lownoisestop,9,0,1,22,1
"Hybrid Manager HM200",heatpump,248,dhw.hybriddhw,hybrid DHW,enum [eco\|high comfort], ,true,select.heatpump_dhw_hybrid_DHW,select.heatpump_dhw_hybriddhw,9,9,1,0,1
"Hybrid Manager HM200",heatpump,248,energypricegas,energy price gas,uint8 (>=0<=254),ct/kWh,true,number.heatpump_energy_price_gas,number.heatpump_energypricegas,9,0,1,20,1
"Hybrid Manager HM200",heatpump,248,energypriceel,energy price electric,uint8 (>=0<=254),ct/kWh,true,number.heatpump_energy_price_electric,number.heatpump_energypriceel,9,0,1,21,1
"Hybrid Manager HM200",heatpump,248,energyfeedpv,feed in PV,uint8 (>=0<=254),ct/kWh,true,number.heatpump_feed_in_PV,number.heatpump_energyfeedpv,9,0,1,22,1
"Hybrid Manager HM200",heatpump,248,switchovertemp,outside switchover temperature,int8 (>=-126<=126),C,true,number.heatpump_outside_switchover_temperature,number.heatpump_switchovertemp,9,0,1,23,1
"Hybrid Manager HM200",heatpump,248,airpurgemode,air purge mode,boolean, ,true,switch.heatpump_air_purge_mode,switch.heatpump_airpurgemode,9,0,1,24,1
"Hybrid Manager HM200",heatpump,248,heatpumpoutput,heatpump output,uint8 (>=0<=100),%,true,number.heatpump_heatpump_output,number.heatpump_heatpumpoutput,9,0,1,25,1
"Hybrid Manager HM200",heatpump,248,coolingcircuit,cooling circuit,boolean, ,true,switch.heatpump_cooling_circuit,switch.heatpump_coolingcircuit,9,0,1,26,1
"Hybrid Manager HM200",heatpump,248,compstartmod,compressor start modulation,uint8 (>=0<=100),%,true,number.heatpump_compressor_start_modulation,number.heatpump_compstartmod,9,0,1,27,1
"Hybrid Manager HM200",heatpump,248,heatdrainpan,heat drain pan,boolean, ,true,switch.heatpump_heat_drain_pan,switch.heatpump_heatdrainpan,9,0,1,28,1
"Hybrid Manager HM200",heatpump,248,heatcable,heating cable,boolean, ,true,switch.heatpump_heating_cable,switch.heatpump_heatcable,9,0,1,29,1
"Hybrid Manager HM200",heatpump,248,nrgtotal,total energy,uint24 (>=0<=167772),kWh,false,sensor.heatpump_total_energy,sensor.heatpump_nrgtotal,9,0,1/100,30,2
"Hybrid Manager HM200",heatpump,248,energypricegas,energy price gas,uint8 (>=0<=254),ct/kWh,true,number.heatpump_energy_price_gas,number.heatpump_energypricegas,9,0,1,23,1
"Hybrid Manager HM200",heatpump,248,energypriceel,energy price electric,uint8 (>=0<=254),ct/kWh,true,number.heatpump_energy_price_electric,number.heatpump_energypriceel,9,0,1,24,1
"Hybrid Manager HM200",heatpump,248,energyfeedpv,feed in PV,uint8 (>=0<=254),ct/kWh,true,number.heatpump_feed_in_PV,number.heatpump_energyfeedpv,9,0,1,25,1
"Hybrid Manager HM200",heatpump,248,switchovertemp,outside switchover temperature,int8 (>=-126<=126),C,true,number.heatpump_outside_switchover_temperature,number.heatpump_switchovertemp,9,0,1,26,1
"Hybrid Manager HM200",heatpump,248,airpurgemode,air purge mode,boolean, ,true,switch.heatpump_air_purge_mode,switch.heatpump_airpurgemode,9,0,1,27,1
"Hybrid Manager HM200",heatpump,248,heatpumpoutput,heatpump output,uint8 (>=0<=100),%,true,number.heatpump_heatpump_output,number.heatpump_heatpumpoutput,9,0,1,28,1
"Hybrid Manager HM200",heatpump,248,coolingcircuit,cooling circuit,boolean, ,true,switch.heatpump_cooling_circuit,switch.heatpump_coolingcircuit,9,0,1,29,1
"Hybrid Manager HM200",heatpump,248,compstartmod,compressor start modulation,uint8 (>=0<=100),%,true,number.heatpump_compressor_start_modulation,number.heatpump_compstartmod,9,0,1,30,1
"Hybrid Manager HM200",heatpump,248,heatdrainpan,heat drain pan,boolean, ,true,switch.heatpump_heat_drain_pan,switch.heatpump_heatdrainpan,9,0,1,31,1
"Hybrid Manager HM200",heatpump,248,heatcable,heating cable,boolean, ,true,switch.heatpump_heating_cable,switch.heatpump_heatcable,9,0,1,32,1
"Hybrid Manager HM200",heatpump,248,nrgtotal,total energy,uint24 (>=0<=167772),kWh,false,sensor.heatpump_total_energy,sensor.heatpump_nrgtotal,9,0,1/100,33,2
"Hybrid Manager HM200",heatpump,248,dhw.nrg,energy,uint24 (>=0<=167772),kWh,false,sensor.heatpump_dhw_energy,sensor.heatpump_dhw_nrg,9,9,1/100,1,2
"Hybrid Manager HM200",heatpump,248,nrgheat,energy heating,uint24 (>=0<=167772),kWh,false,sensor.heatpump_energy_heating,sensor.heatpump_nrgheat,9,0,1/100,32,2
"Hybrid Manager HM200",heatpump,248,metertotal,meter total,uint24 (>=0<=167772),kWh,false,sensor.heatpump_meter_total,sensor.heatpump_metertotal,9,0,1/100,34,2
"Hybrid Manager HM200",heatpump,248,metercomp,meter compressor,uint24 (>=0<=167772),kWh,false,sensor.heatpump_meter_compressor,sensor.heatpump_metercomp,9,0,1/100,36,2
"Hybrid Manager HM200",heatpump,248,metereheat,meter e-heater,uint24 (>=0<=167772),kWh,false,sensor.heatpump_meter_e-heater,sensor.heatpump_metereheat,9,0,1/100,38,2
"Hybrid Manager HM200",heatpump,248,meterheat,meter heating,uint24 (>=0<=167772),kWh,false,sensor.heatpump_meter_heating,sensor.heatpump_meterheat,9,0,1/100,40,2
"Hybrid Manager HM200",heatpump,248,nrgheat,energy heating,uint24 (>=0<=167772),kWh,false,sensor.heatpump_energy_heating,sensor.heatpump_nrgheat,9,0,1/100,35,2
"Hybrid Manager HM200",heatpump,248,metertotal,meter total,uint24 (>=0<=167772),kWh,false,sensor.heatpump_meter_total,sensor.heatpump_metertotal,9,0,1/100,37,2
"Hybrid Manager HM200",heatpump,248,metercomp,meter compressor,uint24 (>=0<=167772),kWh,false,sensor.heatpump_meter_compressor,sensor.heatpump_metercomp,9,0,1/100,39,2
"Hybrid Manager HM200",heatpump,248,metereheat,meter e-heater,uint24 (>=0<=167772),kWh,false,sensor.heatpump_meter_e-heater,sensor.heatpump_metereheat,9,0,1/100,41,2
"Hybrid Manager HM200",heatpump,248,meterheat,meter heating,uint24 (>=0<=167772),kWh,false,sensor.heatpump_meter_heating,sensor.heatpump_meterheat,9,0,1/100,43,2
"Hybrid Manager HM200",heatpump,248,dhw.meter,meter,uint24 (>=0<=167772),kWh,false,sensor.heatpump_dhw_meter,sensor.heatpump_dhw_meter,9,9,1/100,3,2
"Hybrid Manager HM200",heatpump,248,heatingstarts,heating control starts,uint24 (>=0<=16777214), ,false,sensor.heatpump_heating_control_starts,sensor.heatpump_heatingstarts,9,0,1,42,2
"Hybrid Manager HM200",heatpump,248,heatingstarts,heating control starts,uint24 (>=0<=16777214), ,false,sensor.heatpump_heating_control_starts,sensor.heatpump_heatingstarts,9,0,1,45,2
"Hybrid Manager HM200",heatpump,248,dhw.startshp,starts hp,uint24 (>=0<=16777214), ,false,sensor.heatpump_dhw_starts_hp,sensor.heatpump_dhw_startshp,9,9,1,5,2
"Hybrid Manager HM200",heatpump,248,fuelheat,fuel consumption heating,uint32 (>=0<=1677721),kWh,false,sensor.heatpump_fuel_consumption_heating,sensor.heatpump_fuelheat,9,0,1/10,44,2
"Hybrid Manager HM200",heatpump,248,fuelheat,fuel consumption heating,uint32 (>=0<=1677721),kWh,false,sensor.heatpump_fuel_consumption_heating,sensor.heatpump_fuelheat,9,0,1/10,47,2
"Hybrid Manager HM200",heatpump,248,dhw.fueldhw,fuel consumption,uint32 (>=0<=1677721),kWh,false,sensor.heatpump_dhw_fuel_consumption,sensor.heatpump_dhw_fueldhw,9,9,1/10,7,2
"Hybrid Manager HM200",heatpump,248,elheat,el. consumption heating,uint32 (>=0<=1677721),kWh,false,sensor.heatpump_el._consumption_heating,sensor.heatpump_elheat,9,0,1/10,46,2
"Hybrid Manager HM200",heatpump,248,elheat,el. consumption heating,uint32 (>=0<=1677721),kWh,false,sensor.heatpump_el._consumption_heating,sensor.heatpump_elheat,9,0,1/10,49,2
"Hybrid Manager HM200",heatpump,248,dhw.eldhw,el. consumption,uint32 (>=0<=1677721),kWh,false,sensor.heatpump_dhw_el._consumption,sensor.heatpump_dhw_eldhw,9,9,1/10,9,2
"Hybrid Manager HM200",heatpump,248,elgenheat,el. generation heating,uint32 (>=0<=1677721),kWh,false,sensor.heatpump_el._generation_heating,sensor.heatpump_elgenheat,9,0,1/10,48,2
"Hybrid Manager HM200",heatpump,248,elgenheat,el. generation heating,uint32 (>=0<=1677721),kWh,false,sensor.heatpump_el._generation_heating,sensor.heatpump_elgenheat,9,0,1/10,51,2
"Hybrid Manager HM200",heatpump,248,dhw.elgendhw,el generation,uint32 (>=0<=1677721),kWh,false,sensor.heatpump_dhw_el_generation,sensor.heatpump_dhw_elgendhw,9,9,1/10,11,2
"CSH5800iG",heatpump,16,airhumidity,relative air humidity,uint8 (>=0<=100),%,false,sensor.heatpump_relative_air_humidity,sensor.heatpump_airhumidity,9,0,1,0,1
"CSH5800iG",heatpump,16,dewtemperature,dew point temperature,uint8 (>=0<=254),C,false,sensor.heatpump_dew_point_temperature,sensor.heatpump_dewtemperature,9,0,1,1,1
@@ -5703,36 +5709,39 @@ device name,device type,product id,shortname,fullname,type [options...] \| (min/
"CSH5800iG",heatpump,16,hpph1,high pressure side temperature (PH1),int16 (>=-3199<=3199),C,false,sensor.heatpump_high_pressure_side_temperature_(PH1),sensor.heatpump_hpph1,9,0,1/10,13,1
"CSH5800iG",heatpump,16,heatingpumpmod,heating pump modulation,uint8 (>=0<=100),%,false,sensor.heatpump_heating_pump_modulation,sensor.heatpump_heatingpumpmod,9,0,1,14,1
"CSH5800iG",heatpump,16,hpcompspd,compressor speed,uint8 (>=0<=100),%,false,sensor.heatpump_compressor_speed,sensor.heatpump_hpcompspd,9,0,1,15,1
"CSH5800iG",heatpump,16,hybridstrategy,hybrid control strategy,enum [cost optimized\|co2 optimized\|outside temperature alt.\|outside temperature parallel\|heatpump preferred\|boiler only], ,true,select.heatpump_hybrid_control_strategy,select.heatpump_hybridstrategy,9,0,1,16,1
"CSH5800iG",heatpump,16,lownoisemode,low noise mode,enum [off\|reduced output\|switch off hp\|perm. reduced], ,true,select.heatpump_low_noise_mode,select.heatpump_lownoisemode,9,0,1,17,1
"CSH5800iG",heatpump,16,lownoisestart,low noise starttime,uint8 (>=0<=23),hours,true,number.heatpump_low_noise_starttime,number.heatpump_lownoisestart,9,0,1,18,1
"CSH5800iG",heatpump,16,lownoisestop,low noise stoptime,uint8 (>=0<=23),hours,true,number.heatpump_low_noise_stoptime,number.heatpump_lownoisestop,9,0,1,19,1
"CSH5800iG",heatpump,16,hpactivity,compressor activity,enum [off\|heating\|hot water\|defrost\|compressor alarm], ,false,sensor.heatpump_compressor_activity,sensor.heatpump_hpactivity,9,0,1,16,1
"CSH5800iG",heatpump,16,hppower,compressor power output,uint16 (>=0<=31999),W,false,sensor.heatpump_compressor_power_output,sensor.heatpump_hppower,9,0,1,17,1
"CSH5800iG",heatpump,16,hpcurrpower,compressor current power,uint16 (>=0<=31999),W,false,sensor.heatpump_compressor_current_power,sensor.heatpump_hpcurrpower,9,0,1,18,1
"CSH5800iG",heatpump,16,hybridstrategy,hybrid control strategy,enum [cost optimized\|co2 optimized\|outside temperature alt.\|outside temperature parallel\|heatpump preferred\|boiler only], ,true,select.heatpump_hybrid_control_strategy,select.heatpump_hybridstrategy,9,0,1,19,1
"CSH5800iG",heatpump,16,lownoisemode,low noise mode,enum [off\|reduced output\|switch off hp\|perm. reduced], ,true,select.heatpump_low_noise_mode,select.heatpump_lownoisemode,9,0,1,20,1
"CSH5800iG",heatpump,16,lownoisestart,low noise starttime,uint8 (>=0<=23),hours,true,number.heatpump_low_noise_starttime,number.heatpump_lownoisestart,9,0,1,21,1
"CSH5800iG",heatpump,16,lownoisestop,low noise stoptime,uint8 (>=0<=23),hours,true,number.heatpump_low_noise_stoptime,number.heatpump_lownoisestop,9,0,1,22,1
"CSH5800iG",heatpump,16,dhw.hybriddhw,hybrid DHW,enum [eco\|high comfort], ,true,select.heatpump_dhw_hybrid_DHW,select.heatpump_dhw_hybriddhw,9,9,1,0,1
"CSH5800iG",heatpump,16,energypricegas,energy price gas,uint8 (>=0<=254),ct/kWh,true,number.heatpump_energy_price_gas,number.heatpump_energypricegas,9,0,1,20,1
"CSH5800iG",heatpump,16,energypriceel,energy price electric,uint8 (>=0<=254),ct/kWh,true,number.heatpump_energy_price_electric,number.heatpump_energypriceel,9,0,1,21,1
"CSH5800iG",heatpump,16,energyfeedpv,feed in PV,uint8 (>=0<=254),ct/kWh,true,number.heatpump_feed_in_PV,number.heatpump_energyfeedpv,9,0,1,22,1
"CSH5800iG",heatpump,16,switchovertemp,outside switchover temperature,int8 (>=-126<=126),C,true,number.heatpump_outside_switchover_temperature,number.heatpump_switchovertemp,9,0,1,23,1
"CSH5800iG",heatpump,16,airpurgemode,air purge mode,boolean, ,true,switch.heatpump_air_purge_mode,switch.heatpump_airpurgemode,9,0,1,24,1
"CSH5800iG",heatpump,16,heatpumpoutput,heatpump output,uint8 (>=0<=100),%,true,number.heatpump_heatpump_output,number.heatpump_heatpumpoutput,9,0,1,25,1
"CSH5800iG",heatpump,16,coolingcircuit,cooling circuit,boolean, ,true,switch.heatpump_cooling_circuit,switch.heatpump_coolingcircuit,9,0,1,26,1
"CSH5800iG",heatpump,16,compstartmod,compressor start modulation,uint8 (>=0<=100),%,true,number.heatpump_compressor_start_modulation,number.heatpump_compstartmod,9,0,1,27,1
"CSH5800iG",heatpump,16,heatdrainpan,heat drain pan,boolean, ,true,switch.heatpump_heat_drain_pan,switch.heatpump_heatdrainpan,9,0,1,28,1
"CSH5800iG",heatpump,16,heatcable,heating cable,boolean, ,true,switch.heatpump_heating_cable,switch.heatpump_heatcable,9,0,1,29,1
"CSH5800iG",heatpump,16,nrgtotal,total energy,uint24 (>=0<=167772),kWh,false,sensor.heatpump_total_energy,sensor.heatpump_nrgtotal,9,0,1/100,30,2
"CSH5800iG",heatpump,16,energypricegas,energy price gas,uint8 (>=0<=254),ct/kWh,true,number.heatpump_energy_price_gas,number.heatpump_energypricegas,9,0,1,23,1
"CSH5800iG",heatpump,16,energypriceel,energy price electric,uint8 (>=0<=254),ct/kWh,true,number.heatpump_energy_price_electric,number.heatpump_energypriceel,9,0,1,24,1
"CSH5800iG",heatpump,16,energyfeedpv,feed in PV,uint8 (>=0<=254),ct/kWh,true,number.heatpump_feed_in_PV,number.heatpump_energyfeedpv,9,0,1,25,1
"CSH5800iG",heatpump,16,switchovertemp,outside switchover temperature,int8 (>=-126<=126),C,true,number.heatpump_outside_switchover_temperature,number.heatpump_switchovertemp,9,0,1,26,1
"CSH5800iG",heatpump,16,airpurgemode,air purge mode,boolean, ,true,switch.heatpump_air_purge_mode,switch.heatpump_airpurgemode,9,0,1,27,1
"CSH5800iG",heatpump,16,heatpumpoutput,heatpump output,uint8 (>=0<=100),%,true,number.heatpump_heatpump_output,number.heatpump_heatpumpoutput,9,0,1,28,1
"CSH5800iG",heatpump,16,coolingcircuit,cooling circuit,boolean, ,true,switch.heatpump_cooling_circuit,switch.heatpump_coolingcircuit,9,0,1,29,1
"CSH5800iG",heatpump,16,compstartmod,compressor start modulation,uint8 (>=0<=100),%,true,number.heatpump_compressor_start_modulation,number.heatpump_compstartmod,9,0,1,30,1
"CSH5800iG",heatpump,16,heatdrainpan,heat drain pan,boolean, ,true,switch.heatpump_heat_drain_pan,switch.heatpump_heatdrainpan,9,0,1,31,1
"CSH5800iG",heatpump,16,heatcable,heating cable,boolean, ,true,switch.heatpump_heating_cable,switch.heatpump_heatcable,9,0,1,32,1
"CSH5800iG",heatpump,16,nrgtotal,total energy,uint24 (>=0<=167772),kWh,false,sensor.heatpump_total_energy,sensor.heatpump_nrgtotal,9,0,1/100,33,2
"CSH5800iG",heatpump,16,dhw.nrg,energy,uint24 (>=0<=167772),kWh,false,sensor.heatpump_dhw_energy,sensor.heatpump_dhw_nrg,9,9,1/100,1,2
"CSH5800iG",heatpump,16,nrgheat,energy heating,uint24 (>=0<=167772),kWh,false,sensor.heatpump_energy_heating,sensor.heatpump_nrgheat,9,0,1/100,32,2
"CSH5800iG",heatpump,16,metertotal,meter total,uint24 (>=0<=167772),kWh,false,sensor.heatpump_meter_total,sensor.heatpump_metertotal,9,0,1/100,34,2
"CSH5800iG",heatpump,16,metercomp,meter compressor,uint24 (>=0<=167772),kWh,false,sensor.heatpump_meter_compressor,sensor.heatpump_metercomp,9,0,1/100,36,2
"CSH5800iG",heatpump,16,metereheat,meter e-heater,uint24 (>=0<=167772),kWh,false,sensor.heatpump_meter_e-heater,sensor.heatpump_metereheat,9,0,1/100,38,2
"CSH5800iG",heatpump,16,meterheat,meter heating,uint24 (>=0<=167772),kWh,false,sensor.heatpump_meter_heating,sensor.heatpump_meterheat,9,0,1/100,40,2
"CSH5800iG",heatpump,16,nrgheat,energy heating,uint24 (>=0<=167772),kWh,false,sensor.heatpump_energy_heating,sensor.heatpump_nrgheat,9,0,1/100,35,2
"CSH5800iG",heatpump,16,metertotal,meter total,uint24 (>=0<=167772),kWh,false,sensor.heatpump_meter_total,sensor.heatpump_metertotal,9,0,1/100,37,2
"CSH5800iG",heatpump,16,metercomp,meter compressor,uint24 (>=0<=167772),kWh,false,sensor.heatpump_meter_compressor,sensor.heatpump_metercomp,9,0,1/100,39,2
"CSH5800iG",heatpump,16,metereheat,meter e-heater,uint24 (>=0<=167772),kWh,false,sensor.heatpump_meter_e-heater,sensor.heatpump_metereheat,9,0,1/100,41,2
"CSH5800iG",heatpump,16,meterheat,meter heating,uint24 (>=0<=167772),kWh,false,sensor.heatpump_meter_heating,sensor.heatpump_meterheat,9,0,1/100,43,2
"CSH5800iG",heatpump,16,dhw.meter,meter,uint24 (>=0<=167772),kWh,false,sensor.heatpump_dhw_meter,sensor.heatpump_dhw_meter,9,9,1/100,3,2
"CSH5800iG",heatpump,16,heatingstarts,heating control starts,uint24 (>=0<=16777214), ,false,sensor.heatpump_heating_control_starts,sensor.heatpump_heatingstarts,9,0,1,42,2
"CSH5800iG",heatpump,16,heatingstarts,heating control starts,uint24 (>=0<=16777214), ,false,sensor.heatpump_heating_control_starts,sensor.heatpump_heatingstarts,9,0,1,45,2
"CSH5800iG",heatpump,16,dhw.startshp,starts hp,uint24 (>=0<=16777214), ,false,sensor.heatpump_dhw_starts_hp,sensor.heatpump_dhw_startshp,9,9,1,5,2
"CSH5800iG",heatpump,16,fuelheat,fuel consumption heating,uint32 (>=0<=1677721),kWh,false,sensor.heatpump_fuel_consumption_heating,sensor.heatpump_fuelheat,9,0,1/10,44,2
"CSH5800iG",heatpump,16,fuelheat,fuel consumption heating,uint32 (>=0<=1677721),kWh,false,sensor.heatpump_fuel_consumption_heating,sensor.heatpump_fuelheat,9,0,1/10,47,2
"CSH5800iG",heatpump,16,dhw.fueldhw,fuel consumption,uint32 (>=0<=1677721),kWh,false,sensor.heatpump_dhw_fuel_consumption,sensor.heatpump_dhw_fueldhw,9,9,1/10,7,2
"CSH5800iG",heatpump,16,elheat,el. consumption heating,uint32 (>=0<=1677721),kWh,false,sensor.heatpump_el._consumption_heating,sensor.heatpump_elheat,9,0,1/10,46,2
"CSH5800iG",heatpump,16,elheat,el. consumption heating,uint32 (>=0<=1677721),kWh,false,sensor.heatpump_el._consumption_heating,sensor.heatpump_elheat,9,0,1/10,49,2
"CSH5800iG",heatpump,16,dhw.eldhw,el. consumption,uint32 (>=0<=1677721),kWh,false,sensor.heatpump_dhw_el._consumption,sensor.heatpump_dhw_eldhw,9,9,1/10,9,2
"CSH5800iG",heatpump,16,elgenheat,el. generation heating,uint32 (>=0<=1677721),kWh,false,sensor.heatpump_el._generation_heating,sensor.heatpump_elgenheat,9,0,1/10,48,2
"CSH5800iG",heatpump,16,elgenheat,el. generation heating,uint32 (>=0<=1677721),kWh,false,sensor.heatpump_el._generation_heating,sensor.heatpump_elgenheat,9,0,1/10,51,2
"CSH5800iG",heatpump,16,dhw.elgendhw,el generation,uint32 (>=0<=1677721),kWh,false,sensor.heatpump_dhw_el_generation,sensor.heatpump_dhw_elgendhw,9,9,1/10,11,2
"WM10",switch,71,activated,activated,boolean, ,false,binary_sensor.switch_activated,binary_sensor.switch_activated,11,0,1,0,1
"WM10",switch,71,flowtemphc,flow temperature (TC1),uint16 (>=0<=3199),C,false,sensor.switch_flow_temperature_(TC1),sensor.switch_flowtemphc,11,0,1/10,1,1
Can't render this file because it is too large.

View File

@@ -111,10 +111,10 @@ telegram_type_id,name,is_fetched
0x02A0,RC300Curves,
0x02A1,RC300Curves,
0x02A2,RC300Curves,
0x02A5,RC300Monitor,fetched
0x02A5,RC300Monitor,
0x02A6,RC300Monitor,
0x02A7,RC300Monitor,
0x02A8,RC300Monitor,
0x02A8,CRFMonitor,
0x02A9,RC300Monitor,
0x02AA,RC300Monitor,
0x02AB,RC300Monitor,
1 telegram_type_id name is_fetched
111 0x02A0 RC300Curves
112 0x02A1 RC300Curves
113 0x02A2 RC300Curves
114 0x02A5 RC300Monitor fetched
115 0x02A6 RC300Monitor
116 0x02A7 RC300Monitor
117 0x02A8 RC300Monitor CRFMonitor
118 0x02A9 RC300Monitor
119 0x02AA RC300Monitor
120 0x02AB RC300Monitor

View File

@@ -504,30 +504,33 @@ const std::initializer_list<Modbus::EntityModbusInfo> Modbus::modbus_register_ma
REGISTER_MAPPING(dt::HEATPUMP, TAG_TYPE_DEVICE_DATA, FL_(hpPh1), 13, 1), // hpph1
REGISTER_MAPPING(dt::HEATPUMP, TAG_TYPE_DEVICE_DATA, FL_(heatingPumpMod), 14, 1), // heatingpumpmod
REGISTER_MAPPING(dt::HEATPUMP, TAG_TYPE_DEVICE_DATA, FL_(hpCompSpd), 15, 1), // hpcompspd
REGISTER_MAPPING(dt::HEATPUMP, TAG_TYPE_DEVICE_DATA, FL_(hybridStrategy), 16, 1), // hybridstrategy
REGISTER_MAPPING(dt::HEATPUMP, TAG_TYPE_DEVICE_DATA, FL_(lowNoiseMode), 17, 1), // lownoisemode
REGISTER_MAPPING(dt::HEATPUMP, TAG_TYPE_DEVICE_DATA, FL_(lowNoiseStart), 18, 1), // lownoisestart
REGISTER_MAPPING(dt::HEATPUMP, TAG_TYPE_DEVICE_DATA, FL_(lowNoiseStop), 19, 1), // lownoisestop
REGISTER_MAPPING(dt::HEATPUMP, TAG_TYPE_DEVICE_DATA, FL_(energyPriceGas), 20, 1), // energypricegas
REGISTER_MAPPING(dt::HEATPUMP, TAG_TYPE_DEVICE_DATA, FL_(energyPriceEl), 21, 1), // energypriceel
REGISTER_MAPPING(dt::HEATPUMP, TAG_TYPE_DEVICE_DATA, FL_(energyPricePV), 22, 1), // energyfeedpv
REGISTER_MAPPING(dt::HEATPUMP, TAG_TYPE_DEVICE_DATA, FL_(switchOverTemp), 23, 1), // switchovertemp
REGISTER_MAPPING(dt::HEATPUMP, TAG_TYPE_DEVICE_DATA, FL_(airPurgeMode), 24, 1), // airpurgemode
REGISTER_MAPPING(dt::HEATPUMP, TAG_TYPE_DEVICE_DATA, FL_(heatPumpOutput), 25, 1), // heatpumpoutput
REGISTER_MAPPING(dt::HEATPUMP, TAG_TYPE_DEVICE_DATA, FL_(coolingCircuit), 26, 1), // coolingcircuit
REGISTER_MAPPING(dt::HEATPUMP, TAG_TYPE_DEVICE_DATA, FL_(compStartMod), 27, 1), // compstartmod
REGISTER_MAPPING(dt::HEATPUMP, TAG_TYPE_DEVICE_DATA, FL_(heatDrainPan), 28, 1), // heatdrainpan
REGISTER_MAPPING(dt::HEATPUMP, TAG_TYPE_DEVICE_DATA, FL_(heatCable), 29, 1), // heatcable
REGISTER_MAPPING(dt::HEATPUMP, TAG_TYPE_DEVICE_DATA, FL_(nrgTotal), 30, 2), // nrgtotal
REGISTER_MAPPING(dt::HEATPUMP, TAG_TYPE_DEVICE_DATA, FL_(nrgHeat), 32, 2), // nrgheat
REGISTER_MAPPING(dt::HEATPUMP, TAG_TYPE_DEVICE_DATA, FL_(meterTotal), 34, 2), // metertotal
REGISTER_MAPPING(dt::HEATPUMP, TAG_TYPE_DEVICE_DATA, FL_(meterComp), 36, 2), // metercomp
REGISTER_MAPPING(dt::HEATPUMP, TAG_TYPE_DEVICE_DATA, FL_(meterEHeat), 38, 2), // metereheat
REGISTER_MAPPING(dt::HEATPUMP, TAG_TYPE_DEVICE_DATA, FL_(meterHeat), 40, 2), // meterheat
REGISTER_MAPPING(dt::HEATPUMP, TAG_TYPE_DEVICE_DATA, FL_(heatingStarts), 42, 2), // heatingstarts
REGISTER_MAPPING(dt::HEATPUMP, TAG_TYPE_DEVICE_DATA, FL_(fuelHeat), 44, 2), // fuelheat
REGISTER_MAPPING(dt::HEATPUMP, TAG_TYPE_DEVICE_DATA, FL_(elHeat), 46, 2), // elheat
REGISTER_MAPPING(dt::HEATPUMP, TAG_TYPE_DEVICE_DATA, FL_(elGenHeat), 48, 2), // elgenheat
REGISTER_MAPPING(dt::HEATPUMP, TAG_TYPE_DEVICE_DATA, FL_(hpActivity), 16, 1), // hpactivity
REGISTER_MAPPING(dt::HEATPUMP, TAG_TYPE_DEVICE_DATA, FL_(hpPower), 17, 1), // hppower
REGISTER_MAPPING(dt::HEATPUMP, TAG_TYPE_DEVICE_DATA, FL_(hpCurrPower), 18, 1), // hpcurrpower
REGISTER_MAPPING(dt::HEATPUMP, TAG_TYPE_DEVICE_DATA, FL_(hybridStrategy), 19, 1), // hybridstrategy
REGISTER_MAPPING(dt::HEATPUMP, TAG_TYPE_DEVICE_DATA, FL_(lowNoiseMode), 20, 1), // lownoisemode
REGISTER_MAPPING(dt::HEATPUMP, TAG_TYPE_DEVICE_DATA, FL_(lowNoiseStart), 21, 1), // lownoisestart
REGISTER_MAPPING(dt::HEATPUMP, TAG_TYPE_DEVICE_DATA, FL_(lowNoiseStop), 22, 1), // lownoisestop
REGISTER_MAPPING(dt::HEATPUMP, TAG_TYPE_DEVICE_DATA, FL_(energyPriceGas), 23, 1), // energypricegas
REGISTER_MAPPING(dt::HEATPUMP, TAG_TYPE_DEVICE_DATA, FL_(energyPriceEl), 24, 1), // energypriceel
REGISTER_MAPPING(dt::HEATPUMP, TAG_TYPE_DEVICE_DATA, FL_(energyPricePV), 25, 1), // energyfeedpv
REGISTER_MAPPING(dt::HEATPUMP, TAG_TYPE_DEVICE_DATA, FL_(switchOverTemp), 26, 1), // switchovertemp
REGISTER_MAPPING(dt::HEATPUMP, TAG_TYPE_DEVICE_DATA, FL_(airPurgeMode), 27, 1), // airpurgemode
REGISTER_MAPPING(dt::HEATPUMP, TAG_TYPE_DEVICE_DATA, FL_(heatPumpOutput), 28, 1), // heatpumpoutput
REGISTER_MAPPING(dt::HEATPUMP, TAG_TYPE_DEVICE_DATA, FL_(coolingCircuit), 29, 1), // coolingcircuit
REGISTER_MAPPING(dt::HEATPUMP, TAG_TYPE_DEVICE_DATA, FL_(compStartMod), 30, 1), // compstartmod
REGISTER_MAPPING(dt::HEATPUMP, TAG_TYPE_DEVICE_DATA, FL_(heatDrainPan), 31, 1), // heatdrainpan
REGISTER_MAPPING(dt::HEATPUMP, TAG_TYPE_DEVICE_DATA, FL_(heatCable), 32, 1), // heatcable
REGISTER_MAPPING(dt::HEATPUMP, TAG_TYPE_DEVICE_DATA, FL_(nrgTotal), 33, 2), // nrgtotal
REGISTER_MAPPING(dt::HEATPUMP, TAG_TYPE_DEVICE_DATA, FL_(nrgHeat), 35, 2), // nrgheat
REGISTER_MAPPING(dt::HEATPUMP, TAG_TYPE_DEVICE_DATA, FL_(meterTotal), 37, 2), // metertotal
REGISTER_MAPPING(dt::HEATPUMP, TAG_TYPE_DEVICE_DATA, FL_(meterComp), 39, 2), // metercomp
REGISTER_MAPPING(dt::HEATPUMP, TAG_TYPE_DEVICE_DATA, FL_(meterEHeat), 41, 2), // metereheat
REGISTER_MAPPING(dt::HEATPUMP, TAG_TYPE_DEVICE_DATA, FL_(meterHeat), 43, 2), // meterheat
REGISTER_MAPPING(dt::HEATPUMP, TAG_TYPE_DEVICE_DATA, FL_(heatingStarts), 45, 2), // heatingstarts
REGISTER_MAPPING(dt::HEATPUMP, TAG_TYPE_DEVICE_DATA, FL_(fuelHeat), 47, 2), // fuelheat
REGISTER_MAPPING(dt::HEATPUMP, TAG_TYPE_DEVICE_DATA, FL_(elHeat), 49, 2), // elheat
REGISTER_MAPPING(dt::HEATPUMP, TAG_TYPE_DEVICE_DATA, FL_(elGenHeat), 51, 2), // elgenheat
REGISTER_MAPPING(dt::HEATPUMP, TAG_TYPE_DHW, FL_(hybridDHW), 0, 1), // hybriddhw
REGISTER_MAPPING(dt::HEATPUMP, TAG_TYPE_DHW, FL_(nrgWw), 1, 2), // nrg
REGISTER_MAPPING(dt::HEATPUMP, TAG_TYPE_DHW, FL_(meterWw), 3, 2), // meter