mirror of
https://github.com/emsesp/EMS-ESP32.git
synced 2025-12-07 16:29:51 +03:00
MM10 merge from MichaelDvP
This commit is contained in:
@@ -10,6 +10,7 @@ and this project adheres to [Semantic Versioning](https://semver.org/spec/v2.0.0
|
|||||||
### Added
|
### Added
|
||||||
- Solar Module SM200 support
|
- Solar Module SM200 support
|
||||||
- `set master_thermostat <product id>` to choose with thermostat is master when there are multiple on the bus
|
- `set master_thermostat <product id>` to choose with thermostat is master when there are multiple on the bus
|
||||||
|
- MM10 Mixer support (thanks @MichaelDvP)
|
||||||
|
|
||||||
### Fixed
|
### Fixed
|
||||||
- set boiler warm water temp on Junkers/Bosch HT3
|
- set boiler warm water temp on Junkers/Bosch HT3
|
||||||
|
|||||||
@@ -483,7 +483,6 @@ void showInfo() {
|
|||||||
_renderIntValue(" Current pump modulation", "%", EMS_Mixing.hc[hc_num - 1].pumpMod);
|
_renderIntValue(" Current pump modulation", "%", EMS_Mixing.hc[hc_num - 1].pumpMod);
|
||||||
if (EMS_Mixing.hc[hc_num - 1].valveStatus != EMS_VALUE_INT_NOTSET)
|
if (EMS_Mixing.hc[hc_num - 1].valveStatus != EMS_VALUE_INT_NOTSET)
|
||||||
_renderIntValue(" Current valve status", "", EMS_Mixing.hc[hc_num - 1].valveStatus);
|
_renderIntValue(" Current valve status", "", EMS_Mixing.hc[hc_num - 1].valveStatus);
|
||||||
|
|
||||||
}
|
}
|
||||||
}
|
}
|
||||||
}
|
}
|
||||||
@@ -597,7 +596,7 @@ void publishEMSValues(bool force) {
|
|||||||
rootBoiler["sysPress"] = (float)EMS_Boiler.sysPress / 10;
|
rootBoiler["sysPress"] = (float)EMS_Boiler.sysPress / 10;
|
||||||
if (EMS_Boiler.boilTemp != EMS_VALUE_USHORT_NOTSET)
|
if (EMS_Boiler.boilTemp != EMS_VALUE_USHORT_NOTSET)
|
||||||
rootBoiler["boilTemp"] = (float)EMS_Boiler.boilTemp / 10;
|
rootBoiler["boilTemp"] = (float)EMS_Boiler.boilTemp / 10;
|
||||||
if (EMS_Boiler.exhaustTemp != EMS_VALUE_USHORT_NOTSET)
|
if (EMS_Boiler.exhaustTemp != EMS_VALUE_USHORT_NOTSET)
|
||||||
rootBoiler["exhaustTemp"] = (float)EMS_Boiler.exhaustTemp / 10;
|
rootBoiler["exhaustTemp"] = (float)EMS_Boiler.exhaustTemp / 10;
|
||||||
if (EMS_Boiler.wWActivated != EMS_VALUE_BOOL_NOTSET)
|
if (EMS_Boiler.wWActivated != EMS_VALUE_BOOL_NOTSET)
|
||||||
rootBoiler["wWActivated"] = _bool_to_char(s, EMS_Boiler.wWActivated);
|
rootBoiler["wWActivated"] = _bool_to_char(s, EMS_Boiler.wWActivated);
|
||||||
|
|||||||
10
src/ems.cpp
10
src/ems.cpp
@@ -130,11 +130,11 @@ void ems_init() {
|
|||||||
}
|
}
|
||||||
|
|
||||||
// UBAParameterWW
|
// UBAParameterWW
|
||||||
EMS_Boiler.wWActivated = EMS_VALUE_BOOL_NOTSET; // Warm Water activated
|
EMS_Boiler.wWActivated = EMS_VALUE_BOOL_NOTSET; // Warm Water activated
|
||||||
EMS_Boiler.wWSelTemp = EMS_VALUE_INT_NOTSET; // Warm Water selected temperature
|
EMS_Boiler.wWSelTemp = EMS_VALUE_INT_NOTSET; // Warm Water selected temperature
|
||||||
EMS_Boiler.wWCircPump = EMS_VALUE_BOOL_NOTSET; // Warm Water circulation pump available
|
EMS_Boiler.wWCircPump = EMS_VALUE_BOOL_NOTSET; // Warm Water circulation pump available
|
||||||
EMS_Boiler.wWDesinfectTemp = EMS_VALUE_INT_NOTSET; // Warm Water desinfection temperature to prevent infection
|
EMS_Boiler.wWDesinfectTemp = EMS_VALUE_INT_NOTSET; // Warm Water desinfection temperature to prevent infection
|
||||||
EMS_Boiler.wWComfort = EMS_VALUE_INT_NOTSET; // WW comfort mode
|
EMS_Boiler.wWComfort = EMS_VALUE_INT_NOTSET; // WW comfort mode
|
||||||
|
|
||||||
// UBAMonitorFast
|
// UBAMonitorFast
|
||||||
EMS_Boiler.selFlowTemp = EMS_VALUE_INT_NOTSET; // Selected flow temperature
|
EMS_Boiler.selFlowTemp = EMS_VALUE_INT_NOTSET; // Selected flow temperature
|
||||||
@@ -1240,7 +1240,7 @@ void _process_MMPLUSStatusMessage(_EMS_RxTelegram * EMS_RxTelegram) {
|
|||||||
|
|
||||||
void _process_MMStatusMessage(_EMS_RxTelegram * EMS_RxTelegram) {
|
void _process_MMStatusMessage(_EMS_RxTelegram * EMS_RxTelegram) {
|
||||||
uint8_t hc = (EMS_RxTelegram->type - EMS_TYPE_MMStatusMessage);
|
uint8_t hc = (EMS_RxTelegram->type - EMS_TYPE_MMStatusMessage);
|
||||||
if (hc!=0) {
|
if (hc != 0) {
|
||||||
return; // invalid type
|
return; // invalid type
|
||||||
}
|
}
|
||||||
EMS_Mixing.hc[hc].active = true;
|
EMS_Mixing.hc[hc].active = true;
|
||||||
|
|||||||
@@ -251,11 +251,11 @@ typedef struct {
|
|||||||
char version[10];
|
char version[10];
|
||||||
|
|
||||||
// UBAParameterWW
|
// UBAParameterWW
|
||||||
uint8_t wWActivated; // Warm Water activated
|
uint8_t wWActivated; // Warm Water activated
|
||||||
uint8_t wWSelTemp; // Warm Water selected temperature
|
uint8_t wWSelTemp; // Warm Water selected temperature
|
||||||
uint8_t wWCircPump; // Warm Water circulation pump Available
|
uint8_t wWCircPump; // Warm Water circulation pump Available
|
||||||
uint8_t wWDesinfectTemp; // Warm Water desinfection temperature
|
uint8_t wWDesinfectTemp; // Warm Water desinfection temperature
|
||||||
uint8_t wWComfort; // Warm water comfort or ECO mode
|
uint8_t wWComfort; // Warm water comfort or ECO mode
|
||||||
|
|
||||||
// UBAMonitorFast
|
// UBAMonitorFast
|
||||||
uint8_t selFlowTemp; // Selected flow temperature
|
uint8_t selFlowTemp; // Selected flow temperature
|
||||||
|
|||||||
@@ -1 +1 @@
|
|||||||
#define APP_VERSION "1.9.5b6"
|
#define APP_VERSION "1.9.5b7"
|
||||||
|
|||||||